HomeMy WebLinkAboutPermit D08-157 - WESTFIELD SOUTHCENTER MALL - ZUMIEZ - STORAGE SYSTEMZiJMIF7,
2646 SOUTHC
D08 -157
NTER MALL
CRAM' Tukwila
Parcel No.: 6364200010
Address: 2646 SOUTHCENTER MALL TUKW
Suite No:
Tenant:
Name: ZUMIEZ
Address: 2646 SOUTHCENTER MALL , TUICWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT
Address: PO BOX 130940 , CARLSBAD CA 92013
Phone:
Contact Person:
Name: DAVID MURPHY
Address: 2101 9 AV #211 , SEATTLE WA 98121
Phone: 206 341 -9875
Contractor:
Name: FUTURE BUILDERS INC
Address: 1008 NE 122 AV , PORTLAND OR 97230
Phone: 503 252 -9197
Contractor License No: FUTURBI952C2
doc: IBC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
DEVELOPMENT PERMIT
DESCRIPTION OF WORK:
INSTALL MOVEABLE FIPP STORAGE SYSEM IN A NEW RETAIL STORE.
Value of Construction: $0.00 Fees Collected: $150.53
Type of Fire Protection: International Building Code Edition: 2006
Type of Construction: Occupancy per IBC: 0019
* *continued on next page **
Permit Number: D08 -157
Issue Date: 04/24/2008
Permit Expires On: 10/21/2008
Expiration Date: 03/13/2009
D08 -157 Printed: 04 -24 -2008
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
City Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Permit Number: D08 - 157
Issue Date: 04/24/2008
Permit Expires On: 10/21/2008
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
Permit Center Authorized Signature:
doc: IBC -10/06
Date: 1 0 4 [ 7 4 4
I hereby certify that I have read and -', ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied �+ , whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
constru the perform- • - - of wor I am authorized to sign and obtain this development permit.
Signature: % Y `• Date: \(— ZC( -O g
ticv Le
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D08 -157 Printed: 04 -24 -2008
•
City of Tukwila
Parcel No.: 6364200010
Address: 2646 SOUTHCENTER MALL TUKW
Suite No:
Tenant: ZUMIEZ
1: ** *BUILDING DEPARTMENT CONDITIONS * **
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
PERMIT CONDITIONS
Permit Number: D08 - 157
Status: ISSUED
Applied Date: 03/28/2008
Issue Date: 04/24/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
9: ** *FIRE DEPARTMENT CONDMONS * **
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
11: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate
flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3)
12: Install mechanical stops between rolling shelving units so that when units are rooled together, a 6 inch flue space is
maintained to prevent sprinkler obstructions greater than 4 ft. wide.
13: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
14: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18
inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1)
doc: Cond -10/06
D08 -157 Printed: 04 -24 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
doc: Cond - 10/06
* *continued on next page **
D08 -157 Printed: 04 -24 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work
construction or the performance of work.
Signature.
Print Name
a JjOit , Date: L- t . Z L I Da
cos L-1 kr
doc: Cond -10/06 D08 -157
ordinances governing
or local laws regulating
Printed: 04 -24 -2008
SITE LOCATION
Site Address:
Tenant Name: 2.-0 1.4
Property Owners Name: `v./. -s r ( L 7 Cog -Pci P-T1 014 )
Mailing Address: I (p (,i k 51 t 1Z I✓ 13 L \3 p 1 )kre, 110 0 1 WS flN&' 1: k ' (P
City State
CONTACT PERSON
hen your permit is ready to be issued
Name:
Mailing Address:
E -Mail Address:
CITY OF TUKWI
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
2 C00 1.11 N�Je<LL
t\W rt-1 1 Day Telephone: 242(c ° 3Ll } C
- 2-10 t 1 ■∎l (t T 4 - r /J t - ( t. St % 4 r1 4T.- 1 v./ 6 161 2 1
City Zip
v►1 u�� Pl y 'v " l ■) V spy • (4 Fax Number: 201E - 34 I - C n-1
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg; 4) for Plumbing and Gas Piping (pg5)
Company Name: 1 r7e 17 eI Vv‘Mec1
Contact Person:
E -Mail Address:
Contractor Registration Number:
E -Mail Address:
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Q:\Applications\Porms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Building Peni..i N
Mechanical Permit No
Plumbing /Gas Perri it No.
Public Works Permit No.
Project No.
- 01+
or of use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
ARCHITECT OF l
All plans must be wet stamped by Architect of Record
Company Name: C (Z. ' I-A y V P ` 1
Mailing Address: 21(x1 14 it11.-n- / \i t. t 4 211 , -- 5e..44-le i }\ '10 12
s� ,, ,( City State Zip
Contact Person: (/ � P
i 1 7 01 Day Telephone: 2c , -- j 4 1 —' 1 5
ei vv\ I� 1- i A F'1\1 r y Ck iMw((Ai y VaArey , CeryYA Fax Number: 2 o ' - 341 - G \ 1 - 1
ENGINEER OF RECORD "— All . plans must be wet stamped by Enginee of Re
King Co Assessor's Tax No.: 6 - U U) (�
Suite Number: - 2-(4 , 44: , Floor: 2-
New Tenant: :.... Yes
State
P-YiN N Y Day Telephone: (41 A) CA La 3(0
..No
4 100 7c
Zip
Zip
44 &far N fit c1-&
e5oG " 1 64 ' tt Wit 1" t - TV1a v (LLE- FrtK kw,i4s 'Z 1 r2-
Fax Number: C iii) 11S "' 9 43t
Page 1 of 6
BUILDING PERMIT INFORM'ION 206- 431 -3670
Valuation of Project (contractor's bid price): $ '' o Existing Building Valuation: $
Scope of Work (please provide detailed information): fJ( (2v° tp131,E r`'ty ' R( Sy S ryfik
Ir1 /' is. `ZLt"
Will there be new rack storage? X.... Yes
provide All Building Areas in Square Footage B
OW
I Floor
2" Floor
a
loon
Floors
thru
Basement
Accessory, Structure*
Attache Garage
Detached Garage,
Attached C
I
retached Cal
Covered Deck
Uncovered Deck
Interior. Remodel
Addition to
Existing
Structure
pe of
ation per
IBC
Type of
Occupancy per
IBC
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑
Will there be storage or use of flammable, combustible or hazardous materials in the building? . Yes No)
If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantiti s and Materia ci Y`heets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q:\ Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
a E7/-t L STS T ht -t M w r'111" i rl t- 1 s
E.. No If yes, a separate permit and plan submittal will be required.
Compact:
t L
Other (specify)
Handicap:
Page 2 of 6
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath /shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and /or
vent
Additional medical gas
inlets /outlets — six or more
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and /or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets /outlets for specific gas
i PLUMBING AND GAS PIPItr" PERMIT INFORMATION - 206.431 70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
Valuation of Plumbing work (contractor's bid price): $
Valuation of Gas Piping work (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
City State Zip
Day Telephone:
Fax Number:
Expiration Date:
Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc
Revised: 9 -2006
bn
Page 5 of 6
PERMIT APPLICATION NO . 3 -- Applicable to all permits in this ap _.cation
BUILDING OWN R AUTHO
Signature:
Application Accepted:
Print Name: 4 / S, 141 f ct (, f C ?-
Mailing Address: '2-1 C NC. 1 - 2 ll
O J orb
Q:Wpplications\Forms- Applications On Line \3 -2006 - Permit Application.doc
Revised: 9 -2006
bh
Date:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Day Telephone: 2c.p - 34-1 — F'3
INTT Vtf 9f 1 Z
City
State Zip
Date Application Expires: 01 (7-1 w
Staff Initials:
Page 6 of 6
RECEIPT NO: R08 -01329
User ID: 1165
Payee: FUTURE BUILDERS, INC.
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http. //www. ci. tukwila. wa. us
D08 -137 2,174.50
4,7 1 1157723 93.00
M08 -094 316.00
PG08 -097 140.00
TOTAL: 2,723.50
SET RECEIPT
Initials: JEM Payment Date: 04/24/2008
SET ID: 0424 SET NAME: ZUMIEZ
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3065
BUILDING - NONRES
MECHANICAL - NONRES
PLUMBING - NONRES
STATE BUILDING SURCHARGE
TOTAL:
Total Payment: 2,723.50
2,723.50
2,723.50
Account Code Current Pmts
000/322.100 2,258.50
000.322.102.00.0 316.00
000.322.103.00.0 140.00
000/386.904 9.00
TOTAL: 2,723.50
1582 04/24 9711 TOTAL 2723.50
Doc: RECSETS -06
RECEIPT NO: R08 -00957
Initials: JEM Payment Date: 03/28/2008
User ID: 1165
Payee: MURPHY VAREY, P.S.
SET ID: S000000989
SET TRANSACTIONS:
Set Member Amount
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www. ci. tukwila. wa. us
D 01'57 57.53
EL08 -328 143.50
M08 -094 79.00
PG08 -097 32.00
TOTAL: 312.03
ACCOUNT ITEM LIST:
Description
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
SET RECEIPT
Total Payment: 312.03
SET NAME: Tmp set /Initialized Activities
TRANSACTION LIST:
Type Method Description Amount
Payment Check 12013 312.03
TOTAL: 312.03
Account Code Current Pmts
000.345.832.00.0 143.50
000/345.830 168.53
TOTAL: 312.03
" 03/28 0711 TOTAL 312.03
Project:
2 Lt "V1 I i'S
Type of Inspection:
11114
v
Address:
2Co L!(0
1411 A I 1
Date Called:
Special Instructions:
Date Wanted:
7- a -)- oF1
a.m..
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PE MIT NO.
CITY OF TUKWILA BUILDING DIVISION g.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-
Approved per applicable codes. ° Corrections required prior to approval.
COMMENTS:
Date:
$t .00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
p . at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
Project: 7 t
Sprinklers:
Type of Inspection :
r w f 6 ea ,. 1 P c-AL / tyi �-+-
Address: - 1. (n �j (.
Suite #:
rA 0
a N
Contact Person:
Special Instructions:
Occupancy Type:
Phone No.:
Needs Shiftnspection:
Sprinklers:
Fire Alarms,,
Hood & Duct:
Monitor:
Pre -Fire:
Permi
Occupancy Type:
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
PERMIT NUMBERS
444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407
MENTS:
5, �l��.��- �� 0
- r--- A- _
P V N 6 V.-
Approved per applicable codes.
Corrections required prior to approval.
Date:.
2z
V
v
. l
H rs..
:
o $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
- City of Tukwila Finance Department. Call to schedule a reinspection.
Word/Inspection Record Form.Doc 1/13/06
T.F.D. Form F.P. 113
ACTIVITY NUMBER: D08 -157 DATE: 03 -28 -08
PROJECT NAME: ZUMIEZ
SITE ADDRESS: 2646 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
i g ivision
Comments:
Approved ❑
Notation:
Documents/routing slip.doc
2 -28 -02
•PERMIT COORD COPY �
PLAN REVIEW /ROUTING SLIP
Public Works ❑
APPROVALS OR CORRECTIONS:
REVIEWER'S INITIALS:
SI v
Fire Prevention
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 7( Incomplete
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUT NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Approved with Conditions
4-0e
DATE:
DATE:
Planning Division
Permit Coordinator
DUE DATE: 04-01-08
Not Applicable
❑ No further Review Required
n
n
DUE DATE: 04-29-08
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
FUTURBI952C2
Licensee Name
FUTURE BUILDERS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602069738
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
1008 NE 122ND AVE
Address 2
PORTLAND, OR
City
PORTLAND
County
OUT OF STATE
State
OR
Zip
97230
Phone
5032529197
Status
ACTIVE
Specialty l
GENERAL
Specialty 2
UNUSED
Effective Date
3/1/2005
Expiration Date
3/13/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
Business Owner Information
Name
Role
Effective Date
Expiration Date
MEYER, SHAWN
PRESIDENT
02/22/2005
Look Up a Contractor, Electrn or Plumber License Detail
Washington State Department of Labor and Industries
GeneraUSpecialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
OLD
•
Bond Information
Bond Bond
Company Account Effective Expiration Cancel Impaired Bond Received
Bond Name Number Date Date Date Date Amount Date
#3
OLD
REPUBLIC
INS CO
YLI259657
10/25/2005
Until
Cancelled
$12,000.00
10/31/2005
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= FUTURBI952C2 04/24/2008
SHELVING HEIGHT
CEILING HEIGHT: T.D.A.
STATIC SHELVING: 7
MODILE SHELVING: 7-6"
5' -6"
THICK KED
DASHED LINE 1"
INDICATE~
PLASTIC
N ETTI NG, TYP.
DIAGONAL LINE INDICATES
STATIC UNIT. ALL STATIC UNITS
TO RECEIVE FOOTPLATES
AND CONCRETE ANCHORS. ALL
PERIMETER STATIC UNITS
TO RECEIVE WALL ANCHORS.
1 „
1"
n
1
4' -24' —/
L
3'-5" MIN,
EXIT PATH
THICK SLUE I ,
DASHED LINE
INDICATES
PEGBOARD
AND ERASER ANTI -T1P TRACK
OARP, TYP. FRONT ONLY, TYP.
14' -9"
33
Cr
51
NOTES:
1. STEEL SHELVING FRAMEWORK AND NON -FIRE RETARDENT PARTICLEBOARD SHELVES, TYP.
2. USE PLASTIC NETTING IN DETWEEN ADJACENT NON -FIRE RETARDANT PARTICLEBOARD SHELVES ON SPLIT UNITS.
3. PEGBOARD & ERASER B OARD INSTALLED AS PER LAYOUT.
A
X
1
24"
T 24"
12"
i
12"
K 3
TPC
TPC
TPC
TPC
FOR ATTACHMENT SEE
SM DOLT -ON FOOT PLATE DETAIL
(STATIC UNITS ONLY)
POST CONNECTOR TABS MUST SE
LOCKED IN PLACE FOR SAFETY, TYP.
STOCKROOM SHELVING LAYOUT
SCALE: 1/4" I= T -0"
24"
7' 24"
12"
12"
L
15„
301
I
M
( END FRAME AND DAY ELEVATION DETAILS
2 � SCALE: 3/4" =1' -0"
TPC
TPC
TPC
TPC
TPC
PLASTIC NETTING ON
SPLIT UNITS, TYP.
12 TYP
T
30_61, 458
1
14 6 -14 EMPTY SLOTS
148 -14 EMPTY SLOTS
14- -14 EMPTY SLOTS
1
t
14 -14 EMPTY SLOTS
143 -14 EMPTY SLOTS
1
This ( &TSS
FOR 30" DEEP)
TFCV (& TSB
FOR 30" PEEP)
TFCV (& TSS
FOR 30" PEEP)
TFCV (& TSD
FOR 30" DEEP)
TFCV (& TSB
FOR 30" PEEP)
TWD (& TOD FOR 30" DEEP)
- ma & T513 FOR
30" PEEP UNITS, TYP.
TFCV & TSS FOR
30" DEEP UNITS, TYP.
FILE Copy
Permit No. 14fe.e.t
Piar review approval is subject to errors and omissions.
Approval of construction does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy d con . , vns is owieged:
- #10
Dat r
City of Tukwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
n APR 1 O 2008
ity Of Tukwila
B ILDING DIVISION
RENAg 1S the scope
to o changes shall be made approval Of
of work without prio apt? .
Tukwila Building D.V.S;on .
vice a new plan submmat
NCB: Revisions wilt req. I tan review fees.
an d may include additional plan
CITY OF TUKWILA
MAR 2 S 2008
PERMIT CENTER
Voir M
c)
z
O
u)
a
N
111
N
O
N
< (S]
Q
SHEET
L1
14 GA.
1 "
TRIM-LINE P05T
1" TYP.
rMCE
0O 0
NUFACTU]
, NORTH VANCOUVER, SC,
29 -5461 FAX: (604) -92,E
3
1311
ORIENTATION OF FOOT PLATE
TO PREVENT 'TRIP HAZARD"
i 11 1
111 L._
16 16
TRIM -LINE TPC POST CONNECTOR DETAIL
_I
2
16
AISLE SIPE
■
Iii
3 4 "22 "x12 "x11 GA. FOOTPLATE
5 1
0 —'x12" LONG GRADE 5 BOLT
16
CM NYLON LOCK NUT
11 H11
SCALE: 6" -1' -O"
0
[I
0-g" x 34" HILTI KWIK BOLT TZ
CONCRETE= WEDGE ANCHOR
AS PER ESR -1917 IL,
a
■■
0
me
13 GA.
1 1
1-4
3" EMI3.
� �
L �
4 "
1 1
L__I
O
1 TYP.
l
777
n / 11
FLOOR
5M BOLT -ON FOOT PLATE P TAIL (STATIC UNITS ONLY)
LI i
—
36 CONCRETE
L 1 " 4 �'1, 60_1
. , a a
TRIM -LINE TWP FRAME CONNECTOR DETAIL
ZUMIEZ
SOUTHCENTER MALL
TUKWILA, WASHINGTON
5 SCALE: 6" =1' -O"
0 SCALE: 6" =1' -D"
r 13 GA.
- - - -ti p. ,- A ..
- WALL
J 1 ' 1
lin
Q TRIM
U
U
U
0
El
1�"
GYBED_ f� �E
... APPPA D
APR 1() 2°
ow of - rii k v ,o
B ILDIN r)1\f
0 \--\
[
ci__./7
IJ
L. 36 " , 4a 6o-
TRIM -LINE TPC POST CONNECTOR DETAIL
TRIM -LINE FRAME CONNECTOR DETAILS
TRIM -LINE TSB SHELF BAR DETAIL
5M BOLT -ON FOOT PLATE DETAIL
WALL ATTACHMENT DETAIL
, ,
a a a
::::::ME CONNCOR DTAIL
I
I
ATTACHMENT
-LINE POST TRIM-LINE POST
.04' x 3" S WING TOGGLE= BOLT
(SW1E3),'TYP.
DETAIL
30 -
1 8 GA.
- •
4 "
- r
IDIIIHI MM
RECEIVED CITY OF TU}CUVILA
WALL
I I
O O
1 1
BY: GL /Jm
DATE: MAR 26108
SCALE: AS NOTED
FILENAME M904- D- 001 -00
TRIM -LINE TS SHELF I3AR DETAIL
SHE=ET
D1
SCALE 6" =1' -0" MAR 2 8 2008
PERMIT CENTER
N i-' SCALE: 6" = 1' 0"
- TO PREVENT GHOSTING
A COMBINATION OF
(UNWANTED MOVEMENT) & TO ENSURE THE MODILE SYSTEM MOVES FREELY THE TRACK SUPPORT MUST
WOOD & RUBBER SHIMS ARE USED TO LEVEL THE FLOOR.
4
BE MOUNTED ON A LEVEL SURFACE.
16
- WHEN CONNECTING
TO PREVENT THE TRACK
- THE JOINS IN THE
MUST BE STAGGERED.
- TWO CONTINUOUS
- NOTE THAT THE STEEL
- SCREW 15 TO GO THROUGH
v
END STOP
TWO SECTIONS OF TRACK SUPPORT TWO STEEL SPRING PINS MUST BE
FROM FLEXING.
TRACK SUPPORT & THE JOINS IN THE TRACK SHOULD NOT OVERLAP THEY
STEEL STRIPS ARE INSERTED INTO THE TRACK TO PROVIDE THE RIDING
STRIP l5 SHORTER THAN THE TRACK TO LEAVE ROOM FOR AN END
THE END STOP AND RIGHT INTO THE TRACK.
ALUMINUM TRACK
THREADED SCREW
D CONTINUOUS STEEL
STRIP INSERT
l 16 GA. END PLATE
-' ROUND
HEAD SCREW
INSERTED
SURFACE.
STOP.
.�
■
i
r
II.
illl.
i
r
I STEEL
PIN
ALUMINUM TRACK
SUPPORT
41
SPRING
- WHEN CONNECTING
70 PREVENT THE
- THE JOINS IN THE
MUST BE STAGGERED.
- TWO CONTINUOUS
- NOTE THAT THE STEEL
- SCREW 15 TO GO
END STOP
TWO SECTIONS OF TRACK SUPPORT FOUR STEEL SPRING PINS
TRACK FROM FLEXING.
TRACK SUPPORT & THE JOINS IN THE TRACK 5HOULD NOT OVERLAP
STEEL STRIPS ARE INSERTED INTO THE TRACK TO PROVIDE THE
STRIP I5 SHORTER THAN THE TRACK TO LEAVE ROOM FOR
THROUGH THE END STOP AND RIGHT INTO THE TRACK.
ALUMINUM TRACK
-' THREADED SCREW
CONTINUOUS STEEL
STRIP INSERT
r
•
16 GA. END PLATE
- ROUND Q
2
MUST
THEY
RIDING
AN END
N.
BE INSERTED
SURFACE.
STOP.
"r---1111\111111
��
/ ■ • .
i �!
■
r ,-
11
0
i
STEEL SPRING
PIN
UFACTURI
ORTH VANCOUVER, BC, V7I-
-5461 FAX: (604)- 929 -51
I _E
WOOD SHIM
RUBBER SHIM'
WALL
HIGH POINT USE COMBINATION OF WOOD & RUDDER SHIMS
TO CREATE A LEVEL SURFACE
j
-Rig 1111111P-- -.4
_ P''
_1 PP'
- -
FLOOR (SHOWN EXAGGERATED) LOW POINT
TRACK LEVELING DETAIL
I
HEAD SCREW ......./.... � ANTI-TIP ALUMINUM
TRACK SUPPORT
I I
go END VIEW
TRACK, ANTI -TIP TRACK SUPPORT AND ENP STOP DETAIL
END VIEW
r� TRACK ,TRACK SUPPORT AND END STOP DETAIL
SCALE: 6" =1'- 0"
2 � SCALE: 6" = 1' -0"
SCALE: NTS
- TRACK SUPPORT MUST BE ANCHORED TWICE AT EACH END OF TRACK SECTION AND ONCE
1 X 2 KWIK -CON II+ HEX HEAD I
CONCRETE SCREW ANCHOR
, \ ___ ( ••
EVERY 12"
1
ON ALTERNATING SIDES MINIMUM.
ALUMINUM TRACK
I ALUMINUM TRACK
1 SUPPORT
1 ,„
- CARRIAGE MAY OR
- SHOWN WITH OPTIONAL
♦
r �J
--
J
e 1:1 \_ 3 B -"
3 3
' x 24' GRADE
MAY
LOCK
NOT
MOBILE
4
(IF
WASHER
5 BOLT
HAVE CENTER RAILS DEPENDING
DRAKE & ANTI -TIP BRACKET
CENTER.
(IF REQ'D)
SIDE RAIL
J
MIDDLE BRACKET ,1�
REQ'D) J �)
RUBBER
2
#14 x -' HEX HEAD
TEK SCREW
CARRIAGE ASSEMBLY
RAIL
�I
REQ'D
DETAIL
ON
0
BUMPER
PER
4
SIZE AND
CARRIAGE
CORNER
REQ'D PER
LOADING.
END RAIL
D
i
BRACKET
CARRIAGE
ANTI -TIP BRACKET
(IF
REM))
`��
o
-' LOCK WASHER
o r
`
0
0
BRAKE IF RE 'D SECURE
ASSEMBLY TO THE CA RRIAGE
WITH SELF DRILLING T SCREWS
'S
1a
S " x 24' GRADE 5 BOLT
- THE ANTI -TIP BRACKETS ARE TO BE ATTACHED TO THE MOBILE CARRIAGES USING THE CORNER BOLTS OF THE CARRIAGE.
ZUMIEZ
SOUTHCENTER MALL
TUKWILA, WASHINGTON
ANTI-TIP BRACKET -\
0
II
1
FLOOR
ANTI -71P TRACK SUPPORT
„�
FLOOR i
_ - '
f '
" _ = ti
ANTI -TIP BRACKET IN TRACK SUPPORT DETAIL
• •
. .
•
.
ANCHOR TYP. ALUMINUM TRACK SUPPORT I
SUPPORT ANCHORING DETAIL
TRACK LEVELING / TRACK & TRACK SUPPORT DETAILS
TRACK SUPPORT ANCHORING DETAIL / CARRIAGE ASSEMBLY DETAIL
ANTI -TIP BRACKET IN TRACK SUPPORT DETAIL
SHELVING TO MOBILE CARRIAGE & MOBILE CARRIAGE HANDLE ATTACHMENT DETAILS
PEGBOARD & ERASER BOARD ATTACHMENT DETAILS
SCALE: 6 - 1' O'
61.1 '
5 „_
SCALE: 2 --1' -D
C TRACK
„_, „
SCALE: 6 -1 -0
- SHELVING 15 TO BE ATTACHED
TO THE MOBILE CARRIAGE ON
ALL FOUR CORNERS AND AT ANY MIDDLE
PLATES USING
#14 x 3/4" TEK SCREWS.
-�
MOBILE CARRIAGE HANDLE
#14 x1" HEX
ATTACHMENT
.
HEAD
•�
^
........--
b
TEK SCREW
PETAL
1
b
TYP.
HAEN
N A n�
A VI, A ND 5 71
ti
►r
1 PL ATTACH
#14
VERTICAL
PEGBOARD & ERASER
■00-00": APPROXIMATELY
x 1" HEX HEAD TEK SCREW,
SPACING AT APRROX
BOARD ATTACHMENT
"
7YP.
TYP.
12"
DETAILS
.
~
[ 9EWED 9 FDR
ODE
APPROVED
APR 1 o 29B Cif p f T�
ERASER BOARD (IF REQ'D)
ATTACHED 70 END FRAME
60" ABOVE
GROUND LEYEL
`
#14x1 "HEX HEAD
TEK SCREW, TYP.
CITY OF T d1LA
MAR 2 8 2008
�. ee
Q
n
BY; GL/Jm
DATE: MAR 26108
SCALE: AS NOTED
FILENAME: M904 -D- 002 -00
e
l
__
TOP VIEW TOP VIEW
SHELVING TO MOBILE CARRIAGE ATTACHMENT DETAIL
SHEET
rr��
PG
P2
9 "� ,
SCALE: 1 =1 -0
8
SCALE: 1 " - -O' '
= 1'
7 ,
SCALE: 3/4 " =1 -0'
SCALE: