Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-163 - WESTFIELD SOUTHCENTER MALL - GYMBOREE - STORAGE RACKS
GYMBOREE 1066 SOUTHCENTER MALL D08 -163 Parcel No.: 6364200010 Address: 1066 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: GYMBOREE Address: 1066 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: SARAH NIELSEN Address: 1120 E 80 ST STE 211 , BLOOMINGTON MN 55420 Phone: 800 541 -0821 Contractor: Name: PRODIGY CONSTRUCTION MANAG LTD Address: 186 N HIGH ST , COLUMBUS OH 43230 Phone: 614- 337 -0908 Contractor License No: PRODICM966CS DESCRIPTION OF WORK: INSTALLATION OF STORAGE SHELVING IN STOCKROOM Cityllif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D08 - 163 Issue Date: 05/16/2008 Permit Expires On: 11/12/2008 Expiration Date: 04/10/2010 Value of Construction: $0.00 Fees Collected: $239.63 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0019 doc: IBC -10/06 D08 -163 Printed: 05-16 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: governing this work will be c The granting of this pe construction or the pe Signature: Print Nam doc: IBC -10/06 City oinukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N N Start Time: Volumes: Cut 0 c.y. Private: Profit: N Private: • : e c Permit Number: Issue Date: Permit Expires On: Number: 0 Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Public: Non - Profit: N Public: Date: S V DO8 -163 05/16/2008 11/12/2008 I hereby certify that I have read a • examined this permit - d know the same to be true and correct. All provisions of law and ordinances ed with, whether s herein or not. s n pres e to • ive authority to violate or cancel the provisions any other state or local laws regulating e o w• I • Vauthorized to sign and obtain this developmen p t. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -163 Printed: 05-16 -2008 Parcel No.: 6364200010 Address: 1066 SOUTHCENTER MALL TUI W Suite No: Tenant: GYMBOREE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 163 Status: ISSUED Applied Date: 04/01/2008 Issue Date: 05/16/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ** *FIRE DEPARTMENT CONDITIONS * ** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 11: Install mechanical stops between rolling shelving units so that when units are rolled together, a 6 inchg flue space is maintained to prevent sprinkler obstructions greater than 4 ft. wide. 12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 13: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 14: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of doc: Cond -10/06 D08 -163 Printed: 05 -16 -2008 such condition or violation. doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * * continued on next page ** D08 -163 Printed: 05 -16 -2008 I hereby certify that I have this work will be complied The granting of this permit construction or the pe Signature: doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us read these conditions and will comply with them as outlined. All provisions of law and ordinances governing with, whether specified herein or not. does not presume to give authority to violate or cancel the provision of any other work or local laws regulating ance of work. Print Name: it /f -o 7 2 & Date: 5 /6/0 D08 -163 Printed: 05-16 -2008 Site Address: Tenant Name: Mailing Address: Name: Mailing Address: Company Name: F' t) Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIi1 Community Develop% ,t Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Plumbing /Gas Permit No. Public Works Permit Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION ota� -)vv6DwAfici )k4I Property Owners Name: 1—F ' Gb" opt -et ATV - nit E -Mail Address: .1 r a\ Q 44-146r l ° 'f • Cell.. 1A- QI S`G' C'ft & -• -61-D 'in )"V cry -KG- 014 C- A P - a TV chest ,— - ?ov i2 ki hiC4IL King Co Assessor's Tax No.: .' " .qt r t 4" 1 t) Suite Number: City State State Floor: New Tenant: J .... Yes ..No Zip CONTACT PERSON :.= ntact When you slued J H Day Telephone: (& 'V 3 1. 0 A Lett4 At tisruJ 4, zG City State Zip Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (fig 4) for Plumbing and Gas Piping (p City Day Telephone: Fax Number: Expiration Date: Zip ARCHITECT OF R All plans must be wet stamped by Archit 1.414 1-r tiw 63 Z City Sta te Zip Day Telephone: '3 14 4i t 2 41 t o Fax Number: 3 ( 4- 4 t t .?'D NGINEER OF RECORD - All plans must be wet stamped by Enginee 1,0t4. t Avo t 4b City State Zip Day Telephone: 3 ,4_ 4 Gr 2 ► Fax Number: Page 1 of 6 BUILDING PERMIT INFORMATION 206 -431 -3670 Valuation of Project (contractor's bid price). y 515-00 Scope of Work (please provide detailed information): P ZV fit 1 n'" 4 Existing Bui,—,ig Valuation: $ Will there be new rack storage? .... Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Is" Floor, 2 Floor 3""F or Floors emertt Accessory . Struc Attachi Detached Garage. Carport Attach Attach 0 etached Cove k'. Uncov ed Deck tenor Remodel Addition to Existing Structure Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PR('ECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes .... o If `yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11" paper including quantities and Material Safe to Sheets. SEPTIC SYSTEM 0 On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES tpp1icable to all permits in this Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: �i�Ltt Jbl`iL J` Date: /� a Print Name: t` 1-1 VV-P � —�. 1 � " Day Telephone: ( " _ I € Z - Mailing Address: (1 gQ cV `1j 2 ( 1 Pia /h'14J4 f4 ZQ .. City State Zip Date Application Expires: Date Application Accepted: of- !a 0 $ Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh app tion Staff Initials: Page 6 of 6 Fixture Type: Qty Fixture Type: ` Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial ' eceptor, indirect to Clothes washer, domestic Floor drain Sin Dental unit, cuspidor Shower, single he. t trap Urina Dishwasher, domestic, with independent drain Lavatory Water • set Building sewer or trailer park sewer Rain water . stem — per drain (in ' e building) Water heate • d /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair tr alteration of water pipi r _ and /or water treating et pment Repair or alteratt. • of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas j PLUMBING AND GAS PIPI#Q PERMIT INFORMATION - 206- L Contact Person: E -Mail Address: Contractor Registration Number: PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outle eing ' stalled and the quantity below: Q:\Applications\Forms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: Expiration Date: State Zip Sewer: Page 5 of 6 Parcel No.: 6364200010 Permit Number: D08 -163 Address: 1066 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/01/2008 Applicant: GYMBOREE Issue Date: Receipt No.: R08 -01677 Initials: WER User ID: 1655 Payee: PRODIGY CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11203 147.00 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 142.50 000/386.904 4.50 Total: $147.00 Payment Amount: $147.00 Payment Date: 05/16/2008 10:04 AM Balance: $0.00 2503 05/16 9710 TOTAL 147.00 doc: Receiot -06 Printed: 05 -16 -2008 Receipt No.: R08 -01003 Initials: JEM User ID: 1165 Payee: ELDER -JONES ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D08 -163 Address: 1066 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/01/2008 Applicant: GYMBOREE Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 51159 92.63 Account Code Current Pmts 000/345.830 92.63 Total: $92.63 Payment Amount: $92.63 Payment Date: 04/01/2008 05:04 PM Balance: $147.00 `4 661 )4/02 ? TOTAL ?2.03 doc: Receiot -06 Printed: 04 -01 -2008 Project:: MI\ Type of Inspection: Address: \ I ? cnc 0 tkc '\ Date Called: . Special Ins ructions: • D ate Wa : • ' 1 O p m. Requester: Phone Nq;, l 4.1, — _a° I INSPECTION NO. In ector: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION q" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: oi )4.4 Dat ' q El $60.00 REINSPECTION REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 4N 11 fir' >' ,.•:-w: ti Pro' y�)eo�f Type of Inspection: , /AJ ( Address: ,.y� 3066 / 9 / 4 // Date Called: „-c Special Instructions: Date Wanted: - (3 y n p.m. Requester: Phona Isli - .3JCJ- . / / a • i 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K.. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 2Z COMMENTS: Inspector: Date: 7 / , $60.00INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at"b300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: COMMENTS: Sprinklers: Hood & Duct: Type } pe of Inspection: --- L 67 .� -1 (A 6 c Address: k )(-_ C. C t"• Suite #: ilk A . t, L_ Contact Person: Special Instructions: Phone No.: IAA (_,'_ L- - 0k_ IF::ic t -ti ( tkie - 04 !;) c P il_ 1 Pi tL LE 3e- 1--'t 0.4 Ai 0 tL-- re Actz Rt-1t- - -4 __ 0f--- (pLT,. 0 C. L_ b .. c= �--, 0 1 j C f i ( r • (AO 0 kL — ,z7 ‘F,-, ki b t.:sl („ hit. -1") C. hi 0 :2 G uikt. . Project: 6 k . ; Sprinklers: Hood & Duct: Type } pe of Inspection: --- L 67 .� -1 (A 6 c Address: k )(-_ C. C t"• Suite #: ilk A . t, L_ Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Hood & Duct: Fire Alarm: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS 206 - 575 -4407 n Approved per applicable codes. ____JA cirrections required prior to approval. Inspector: Date: t i-o g Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 COMMENTS: Sprinklers: Type of Inspection: &(\/"‘ Li /--- ,/ A r ------ ; t il Address: - i I ' ' Suite #: • Jr ' --/ F N c Li L. k c LA : ,,, -c7p.: L ,od ( A r 7, . • f i , t : I .( t - ,:i.., A- + , / Phone No.: - <: 4-7 p , i_..... c:'.. L - ( C * :. ,_, j e p.;) -C 1 7 & ) 4- -.9.. F.-4 it t ,._, , 4 k - f - if .Cr-A, 1 el .... Project: ' - i_, y) 1:-,t,,)"P-.4 , Sprinklers: Type of Inspection: &(\/"‘ Li /--- ,/ A r ------ ; t il Address: - i I ' ' Suite #: • Jr ' --/ --( ivIA j 4.- . Contact'Person: , O, 3/A Special Instructions: , / Phone No.: - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT - 03- - S PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Approved per applicable codes. Corrections required prior to approval. Inspector: /72 Date: 7/9, ( Hrs.: I 1 n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form. Doc 1/13/06 T.F.D. Form F.P. 113 G. OHANIAN BY DATE 3 -20 -08 SUBJECT SEISMIC ANALYSIS OF STORAGE PAS PIPP MOBILE SYSTEM FOR: GYM BOREE 1056 SOUTHCENTER MALL TUKWILA, WA. 98188 PER IBC `20-06 EDITION STORAGE SHELVING CAPACITY: 50 # / LEVEL CALCS. 1 THRU 3 DRAWINGS: RD -13116 RAdK DENIC N & EN(INEERIN( do. 412 WEST BROADWAY, SUITE 204 dLENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 r r .., REVIEWED OMPLIANCE CODE C APPROVED SHEET NO 1 JOB NO. RD - 13116 FILE COPY EXPIRES 12 -26 -09 ..� iP' fir" i c- 77'9sdcne ,,. CITY OF TUKWILA APR 0 12008 PERMIT CENTER By G. OHANIAN DATE 3 - 20 - 08 SUBJECT HANG UNITS DRB BEAM 1 3/32' SEISMIC DESIGN V= Sdsxl x W Rx 1.4 1 =1 R =4 Sds =1 W= D.L. +L.L. LOAD PER COLUMN L.L.= 6x.051(..15 K 2 coL. W =.2 + 15 L. - . 5E- D.L. V 1x1 x.35 = 06 K 4x1.4 • 18" inbrougtme I SIDE VIEW t =14 GA. I x =.22 S x =.13 F Y= 36 Ks!. RACK DEOIQN & ENGINEERING CO. 412 WEOT BROADWAY, QUITE 204 (tLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 IBC 2006 ASCE 7 (SEC. 15.5.3) MOBILE FOLD UNITS LIGHT DRB BEAM t=11 GA. I =.05 S x =.05 F =36 Y .06 1 /4 "0 BOLTS 2 PLACES 100 # / LEVEL 50 # / BEAM M= 48 "x K = 3 "K 8 S R 22 = .02 <.05 SHEET NO, 2 JOB NO. RD -13116 MOBILE HANG UNITS BY G. OHANIAN DATE. 3 -20 -08 SUBJECT COLUMN BASE PLATE 3 I/4' MOBILE SHELVING COMBINED STRESS RATIO P P +M —55 +148= .29 <1.33 Pa a ANCHOR SHEAR — •OZ K- .03K MOMENT AT BEAM CONNECTION M _ .42 +.35= .39 "K CONN 2 V = . 25x3 . 14 x80x.4 =1.5 K RIVET 4 Ma = 1.5 "x1.33 =3.0 " CONN RACK DEMON & ENGINEERING CO. 412 WEOT BROADWAY, IUITE 204 (ILENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 A =.40 Imin =. S min .08 r min = • 54 Q =.75 FY =36 KSI OVERTURNING = .06 "x.5x1.15 = 13.2 "K M MR = .35 "= 25.2 "K NO UPLIFT ALL SINGLE FIXED UNITS TO BE CONNECTED TO THE BUILDING WALL PER DETAIL DRAWING USE (2)-1/4"g5 ANCHORS @ "T" POSTS PER BASE PLATE, 2" EMB. HILTI KWIK BOLT -3 ANCHORS ESR -1385 OR APPROVED EQUAL BEAM — .25 "0 RIVET Fy = gO KSI K1 14 _ rx .54 -26 F 13.8' ' P F =5.5 M a = min F 1.8 "K 4 4 4 J >v 1 4 Ln— ANTI TIP TRACK ANCHORD TO FLOOR W/ 1/4"0 ANCHORS ® 24" o.c. ANTI —TIP BOLTED TO MOBILE CARRIAGE W/ (2) 1/4"0 BOLTS SHELVING POST CONNECTED TO CARRIAGE W/ (2) 1/4 "0 TEK SCREWS PER POST COLUMN SHEET NO 3 JOB NO. RD-13116 ACTIVITY NUMBER: D08 -163 DATE: 04 -01 -08 PROJECT NAME: GYMBOREE SITE ADDRESS: 1066 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: B i • g ivision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PLAN REVIEW /ROUTING SUP •PERMIT COORD COPY I AM) 1 -T 6 Fire Prevention Structural Incomplete Planning Division Permit Coordinator DUE DATE: 04-03-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DUE DATE: 05-01-08 Not Approved (attach comments) DATE: n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PRODICM966CS Licensee Name PRODIGY CONSTRUCTION MANAG LTD Licensee Type CONSTRUCTION CONTRACTOR UBI 602362604 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 186 N HIGH STREET Address 2 City COLUMBUS County OUT OF STATE State OH Zip 43230 Phone 6143370908 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 2/10/2004 Expiration Date 4/10/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HOLBROOK, JOE PRESIDENT 02/10/2004 Impaired Date GUNNOE, BRIAN VICE PRESIDENT 02/10/2004 CINCINNATI INS CO Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CINCINNATI INS CO B8857387 03/11/2004 Until Cancelled $12,000.00 03/29/2004 THE Look Up a Contractor, Electric or Plumber License Detail Washington State Department of Labor and Industries GeneraUSpecialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PRODICM966CS 05/16/2008 1. THE COMPLETE CONSTRUCTION DOCUMENT SET IS INCLUSIVE DRAWING INDEX, THE TENANT INVITATION TO BID PACKAGE, AND ALL MAIL CONSTRUCTION REQUIREMENTS. 2. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. GYMBOREE STORE NO. 383 SOUTHCENTER MALL 1056 SOUTHCENTER MALL TUKWI TUKWILA, WA 98188 _ V 113@-tee - NORDSTROM MACY'S BE IMMEDIATELY REPON I LU TO THE TENANT PROJECT MANAGER TO THE PERFORMANCE OF ANY WORK IN QUESTION. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PAYING FORA SUBCONTRACTORS, HVAC, ELECTRICAL, PLUMBING, ETC.). 4. SUBMIT A SPECIFIC CONSTRUCTION SCHEDULE AND A SCHEDULE PROJECT MANAGER WITHIN SEVEN DAYS AFTER THE AWARD 5. WHEN CONTRACTOR ACCEPTS DELNERY OF Ali ITEMS NOTE IN CONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/ 6. THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ORDINANCES. 7. DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT AND NEIGHBORING TENANTS. 8. 'TYP.' SHOULD MEAN THAT THE CONDMON IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT. UNLESS OTHERWISE NOTED, DETAILS ARE USUALLY KEYED AND NOTED 'Ti?.' ONLY ONCE WHEN THEY FIRST OCCUR. 9. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR SHALL ALERT THE TENANT PROJECT MANAGER AND THE ARCHITECT OF ANY GROSS INCONSISTENCIES BETWEEN SCALED DIMENSIONS AND WRITTEN DIMENSIONS. 10. ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS AND NUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPENCIES BETWEEN ARCHITECTURAL DRAWINGS AND ENGINEERING DRAWINGS, THE GENERAL CONTRACTOR SHALL NOTIFY THE TENANT PROJECT MANAGER IMMEDIATELY. 11. HORIZONTAL DIMENSIONS ARE SHOWN FROM THE FINISHED FACE OF CONSTRUCTION, UNLESS OTHERWISE NOTED. 12. VERTICAL DIMENSIONS ARE FROM THE TOP OF FLOOR FINISH, ESTABLISHED BY THE CONTRACTOR SUBJECT TO THE APPROVAL OF THE TENANT OR ARCHITECT, UNLESS OTHERWISE NOTED. 13. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE APPROVAL OF THE TENANT PROJECT MANAGER OR THE ARCHITECT UNLESS NOTED + / -. 14. DO NOT SUBSTITUTE, REVISE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE TENANT PROJECT MANAGER. 15. COORDINATE ALL WORK AS REQUIRED WITH THE LANDLORD'S REPRESENTATIVE INCLUDING COMPLIANCE "MALL WORKING RULES", LOCAL NOISE ORDINANCES, THE USE OF ELEVATORS, TEMPORARY STORAGE, LOADING DOCKS, BUILDING KEYING SYSTEMS, ETC. PROVIDE NECESSARY BARRICADES, LIGHTING, SIGNAGE, AND GUARDRAILS AS REQUIRED BY OWNER AND/OR APPLICABLE REGULATORY ADVISORY FOR THE PROTECTION OF BUILDING OCCUPANTS, WORKERS AND PEDESTRIANS. 16. GENERAL CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING, RESTORING, REPAIRING AND THE UKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGED SURFACES RESULTING FROM THE WORK TO THEIR ORIGINAL CONDITION. ALL ROOF PATCHING SHALL RETURN AREA TO "LIKE NEW CONDITION. PRIOR TO BIDDING, G.C. TO VERIFY ANY ROOF WARRANTIES WITH LANDLORD AND INCLUDE IN CONTRACT. 1 7. IN THE EVENT HAZARDOUS MATERIALS ARE ENCOUNTERED ON THE PREMISES DURING THE EXECUTION OF THE WORK, NOTIFY THE TENANT AND LANDLORD IMMEDIATELY BEFORE PROCEEDING WITH THE WORK. 18. CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2 - A OR 2- A /10BC WITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING DURING CONSTRUCTION. 19. PATCH AND REPAIR All FIREPROOFING DAMAGED OR RE1vIO D DURING THE PERFORMANCE OF THE WORK. 20. EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF HIS WORK ON A DAILY BASIS. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH, INCLUDING OWNER- FURNISHED ITEMS AND TRASH GENERATED BY OWNER'S CONTRACTORS FOR THE DURATION OF THE PROJECT. JC PENNEY l I I , I ' al LANDLORD: OWNER/TENANT: ARCHITECT: MEP: WESTFIELD CORPORATION, INC 11601 WILSHIRE BLVD. 14th FLOOR LOS ANGELES, CA 90025 TEL: 310- 893 -4761 FAX: 310 -689 -5532 CONTACT: JOSH KIMMEL EMAIL: jkimmel ®westfield.com GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 TEL: (415) 278 -7989 FAX: (415) 278 -7550 CONTACT: MELINDA DE LA CRUZ EMAIL melinda_delacruzC�gymboree.com ARCVISION, INC. 1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146 TEL: (314) 415 -2400 FAX: (314) 415 -2300 CONTACT: GREG WINCHESTER EMAIL: gwinchester@arcv.com ARCVISION, INC. 1950 CRAIG ROAD, SUITE 300 ST. LOUIS MO 63146 TEL: (314) 415 -2400 FAX: (314) 415 -2300 CONTACT: GREG WINCHESTER EMAIL: gwinchester@arcv.com �R �® F ®� CODE COMPLIANCE APPROVED APR ON , �- � 'ukWl�d Of ¢,.,`,.. - °., . BUIL _ .. w� . I Vl[S ON ; - 47,1 rER PKWY. 11 ! m . ao c5 1 J i ----LJ GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 SEARS � �� . GYMBOREE SPACE #1240 FREDERICK J. GOGLIA ARCHITECT, NCARB, ISP 1950 CRAM ROAD, SUITE �°0 ST. LOUIS, MO PH. (314) 415 -2400 FAX (314) 415 -2300 wwwercv ccm LEVEL: 1 OF 3 N CC (+' m CO m M z g qq 5i! o L; CO rn 6 ( . 9 J -1 W Q W - Z IX M VICINITY MAP MALL KEY PLAN ACOUS. ACOUSTICAL Jr. T. JOINT A.D.A. AMERICANS WITH DISABILITIES ACT LAM. LAMINATE ADJ. ADJUSTABLE LAV. LAVATORY A.F.F. ABOVE FINISHED FLOOR UN. LINEAR ALUM. ALUMINUM LL LANDLORD ALT. ALTERNATE LP. LOW POINT A • APPROXIMATE LT. LIGHT ARR CHCH. . ARCHITECTURAL MAX. MAXIMUM BD. BOARD MDO MEDIUM DENSITY OVERLAY BLDG. BUILDING MECH. MECHANICAL BLKG. BLOCKING MFR. MANUFACTURER B.O. BOTTOM OF MIN. MINIMUM CAB. CABINET MISC. MISCELLANEOUS Fl LNG M.O. MASONRY OPENING CL CLOSET CLR CLEAR MID. MOUNTED MIL METAL COL COLUMN (N) NEW CONC. CONCRETE N/A NOT APPLICABLE CONSTR. CONSTRUCTION N.I.C. NOT IN CONTRACT CONT. CONTINUOUS NOM. NOMINAL CTR. DOUBL NO. or # NUMBER DBL DOUBLE N.T.S. NOT TO SCALE DIM. DIMENS ON O.C. ON CENTER DN. DOWN OPNG. OPENING OPP. OPPOSITE DWG. P. LAM. PLASTIC LAMINATE (E ) EXISTING PLYWD. PLYWOOD EA. EACH PR. PAIR EL ELEVATION P.T. PRESSURE TREATED ELEC. ELECTRICAL REC. RECESSED EMER. EMERGENCY R REV. REVISION EQ. EQUAL REQ'D. REQUIRED EQUIP. EQUIPMENT RM. ROOM �• EXTERIOR R.O. ROUGH O PENING F.D. FLOAT ALARM EN510N S.C. SOLID CORE SCHED. SCHEDULE F.E.C. FIRE EXTINGUISHER CABINET SIM. SIMILAR FIN. FINISH SPEC. SPECIFICATION F.H.C. FIRE HOSE CABINET SQ. FT. SQUARE FEET FUR. FLOOR S.S. STAINLESS STEEL FLASH. FLASHING S.T.C. SOUND TRANSMISSION COEFFICIENT FLUOR. FLUORESCENT STD, STANDARD F.O.F. FACE OF FINISH 511. STEEL F.O.M. FACE OF MASONRY STOR. STORAGE F.O.S. FACE OF STUDS STRL STRUCTURAL SUSP. SUSPENDED F.R.T. GAUGE RETARDANT TREATED TEMP. TEMPERED SYM. SYMMETRICAL G.C. GENERAL CONTRACTOR GYP. GYPSUM H.C. HOLLOW CORE THK. THICK HDCP. HANDICAP T P. TYPICAL CONCRETE HDW. HARDWARE OTHERWISE NOTED HT. HEIGHT U.S. UNDERSIDE HORIZ. HORIZONTAL VERT. VERTICAL H.P. HIGH POINT V.I.F. VERIFY IN FIELD HR. HOUR IN. INCH W.C. WATER C L OSET WO. WOOD INSUL INSULATION W.R. WATER RESET INT. INTERIOR JST. JOIST W/ WITH SCOPE O F WORK APPLICABLE CODES EDTITON BUILDING CODE INTE BUILDING CODE 2006 MECHANICAL CODE INTERNATIONAL MECHANICAL CODE 2006 P LUMBING COD: UNIFORM P LUMBING CODE 2006 ELECTRICAL CODE NATIONAL ELECTRICAL CODE 2005 ENERGY CODE WASHINGTON STATE ENERGY CONSERVARION CODE 2006 FIRE CODE INTERNATIONAL FIRE CODE 2006 r LLI o0 ~ I IX Z Z co 61 w _ Z - 15 b _ a x - RED NS No changes shall be made to thin sc ope I o f work without prior approval of I Building Tukwila BUildin Division f NOTE: Revisions will require a new plan submlttaI Y include additi p lan review fees. r I- V ~ 0 g co w D co co -3 co Q 1 Q 0 O L C!_ ° .o OCCUPANCY USE GROUP: M - MERCANTILE co a N r•) 1 - M ce w 0' z re w fa m I g3 BUI LDING CONSTRUCTION TYPE II - B UNPROTECTED NONCOMBUSTIBLE SPRINKLER SYSTEM: YES PROJECT TEAM TOTAL OCCUPANT LOAD: 59 . ARCHITECTURAL QUANTITY OF EXITS REQUIRED: 2 SEISMIC ZONE 2 A0.0 PROJECT INFORMATION FILE COPY A2.2 FURNITURE PLAN A4 STOCKROOM ELEVATIONS P� NQ. A5.1 STORAGE SHELVING DETAILS P review ap proval to o g t ol'i B of � � t,.� r� , ®.: .T{11'sa the vio of - �'�' ns � ed • o1 a PPed d _. _.... . /4 �� fie: �_... __.... . G of �� BUILDING ;� CITY ITY OF TUlCWILA APR 01 2008 PERMIT CENTER 17 go■ V 4 ; CODE SYNOPSIS AREA OCCUPANT OCCUPANT BREAKDOWN ( FT.) LOAD FACTOR LOAD ) I. SALES AREA: 1,700 30 57 INCLUDES SALES FLOOR, ENTRY VESTIBULE 2. BACK OF HOUSE: 560 300 2 ABBREVIATIONS 6897 REGISTET `Ct�IT" T DERICK J. GOGLIA IIITE OF WASHINGTON INCLUDES STOCK /STAGING, TOILET ROOM(S), & CORRIDOR * STOCKROOM ONLY: 388 SQ. Fr. 17.2 % OF GROSS ELEVATION, SECTION REF. I X I FINISH KEY DRAWING NUMBER © DETAIL REFERENCE 4111111010 FURNITURE KEY 3. OTHER IMPROVED: 0 - - DRAWING NUMBER L REVISION NO. 4. UNIMPROVED AREA: 0 PROJECT INFORMATION 0 COLUMN MARKER -45- DATUM POINT 0 KEY NOTE 0 DOOR MARK ALL SPACE ABANDONED BY TENANT OR RETURNED TO LANDLORD 5. GROSS AREA: 2,260 58 (1 + 2 +3) DOES NOT INCLUDE #4 UNIMPROVED AREA SHEET NUMBER: AO . 0 GENERAL NOTES SYMBOLS SQUARE FOOT BREAKDOWN DRAWING INDEX I® I � I I I cyNmg FIRE EXTINGUISHER . - - - – — -- � 4 6 ; ; 5 • 1 � �1 4. �i , 1 i - - - - - .i. ` " r 1 I ; J , , , • I I4 I 54 X60 Vii � , ° 48 x48 ;i M2048 ;; - - - -- , BG , rr � � .r � ' , � _ i - -- ` 1 6,-, /. / /// I III ii r - - -- �1r It �` =�= — � 1 � -I- - � \ `-F [ IC"/-6) I -- � -, ,` I Z T J i I � I Q n u Q u I j d0 1 GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 I I (018 7- ) I P02 J dn>1 ������_�_�_�:�_�_..:.._ i. i i ; ; 55 55 I . 1 I I ji II p w I I Q m n n n FREDERICK J. GOGLIA ARCHITECT, NCAFIB, EP 1950 CRAIG ROAD, SURE 300 ST. LOUIS, MO 63146 Ft- (314) 415x2400 FAX (314) 415 -2300 www. rcv.cam STAGING AREA _i .� -� F9 00 r r ` rnv '�' V `` '1 I /0 11 __� __ F218 r� ° _, �' ,, d 1 1 H : 4°X60 1.A \ u � � 1 I ,�=-4 I I L— _ _ _ _ _ 1 Q m I I i I ►I u 0 p 1 j I I L _ _ _ _ J If/ I - L .. / D i I T ii i � i _ _ - 28 I W r m CO 3 M z g CC 0 1— p cn I J J W Q W 2 n' J • •i I i ' 1 I 1 I Q m ' ► n " I I IQ 1 m' STOCKROOM 11 s J �� A D G Q a 551— r o J ! \I '-' 5,11 l ' ' E ; a F216 1 — – � n v � , 1 I I„ I ii rr - 54"X60' r5l. - - l \ ;j i ' \ I Co , SALES AREA 0 ' rr y [ -- - L ii %r ' iir s, I 'll um p� r i� I I - -I r— I I I I —, I I - x F218 I m I - — > ►. ww��w�wA w> � w'r►w►r � r ..r �r. / ` p J ' - -- tl -- 1 111 I J I �_ 48" 48"1 I 0- � -- �— _ �� I , °I \ I L ti TOILET ROOM ■ I I I _� _ L I — J I ' I m ° n _.� I n u F183 F183 , � 1 Q 17L p i � � rr r p 1 . F900 • o ! r i P178 r �16� 18 (169 . � a r r - I FOR + �■■r7 r# II 1 BB ' I ► ' KB 11E-VIEWED \ r____.. D E c:i C_ E I AP RO 1 _ _ _ _ _ _ _ .. _ ___ _ _ _ _ _ _ 7 E., pt f __:: = 44 WIDE EXff1NG PATH OF TRAVEL FURNITURE PLAN (HYPOTHETICAL) KEY FIXTURE KEY FIXTURE 1. ALL FURNITURE PROVIDED BY DISPLAY FIXTURE VENDOR U.O.N. AND REQUIRES PARTIAL ASSEMBLY FOR INSTALLATION. CONTACT: GRAND & BENEDICTS, MOLLY CROUSEF AT (503) 797-0641. 172) 0 8 +ft. 1 0 3 CITY OF TUKWL.A APR 012008 PERMIT CENTER CASHWRAP (BY MILLWORK VENDOR) FROSTED PLEX SHELVES BACKWRAP (BY MILLWORK VENDOR) CEBD POSTER LIGHT PANEL (LIGHT BOX) F001 LADDER FIXTURE NEW BORN AREA SIGN NB T -STAND C� BABY GIRL AREA SIGN WARDROBE FIXTURE BB BABY BOY AREA SIGN F183) ° S ° CART FIXTURE C. KID GIRL AREA SIGN CF214A) 1/2 ° S ° CART FIXTURE KID BOY AREA SIGN KB BOY'S NESTING TABLE F218 DISPLAY TABLE F216 0900 REfANGULAR HANGRAIL ROUNDER WINDOW PLATFORM F2448 M2048 SLATWALL MIRROR (018 SLATWALL "FIN" DMDER P021 FITTING AREA CURTAIN ROD W /CURTAIN SORBETII "PLUS" PANEL FIXTURE P169 CP178) SORBETTI TV BOX /"PLUS" PANEL FIXTURE SHEET NOTES FURNITURE SCHEDULE FURNITURE NOTES WALL MOUNTED D O .......) D 0 SHELVING, SEE + 12' -O" A.F.F. B.O. A.C.T. CEILING I C -2 I GYM BOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, ANCISCO, CALIFORNIA 94105 + O' -D" A.F.F. di r 1 I� �� s — FIXED FIXED MI __ 6----___ f �. I J — ' FREDERICK J. GOGLIA ARCHITECT, NGARB, ISP 1950 CRAIG ROAD, SURE 300 sr. Lam MO PH. (314) 415-2400 FAX (314) 415-2300 www.arcv.com NEW ELECTRICAL � PANELS 1 I COAT 1 � Mani • — — ` , / '• I / a ■ ■ l / r - ! e = o - - - - - _ ® II FILE ... SAFE _: �-- - I 1 ! ± . � / / – MOBILE SHELVING (3' - W. t I B -3 I FINISH FLOOR x 8'--O" H. x 1'--6" D.), TYP. T1'P. 1 B INSTALL 24" X 36" BULLETIN BOAR I O l u ABOVE DESK/ UNDER LIGHT FIXTURE m co = M z w Ix w h E � -) Q ELEVATION AT STOCK / MANAGER'S DESK 1i4,. 3 � ���°�� 1 1 -------.16r \ c001- ovf.0 Vs CM D 103 RECEIVED CITY OF TUKWILA APR 01 Z008 PERMIT CENTER T—POST 111111111° . (INTERMEDIATE g J t f q g 1 COL.) . L—POST (c el l I t) -,, tl (END ) f g COL.) .01 . '-- =:- .,..- _.-- . o ---' LVI 6 0 1 3/32" 2A ..... ._. j o 1.) g 0 o........, • .... „ vo ,,-----"-:--:---- to _ e" ri $ c 4 4,,,z ge ter, 1 5/1 11 GA. 1/4 RIVET L.A. RR. #25534 ASTM A-502 .. ... >•„,....---"•■■,___-•--_■-•-r'•7 -• i;-..»...- rot) I II II I u 1 s a; W rt.- II II ( II J 11 OA W _........./ Gik. 1 ,.,,,,-."".'1;1 9 r ,_ -='•. 9 V V 4 -• 1/4"0 TEK SCREW (T) -,z2 II • K oto. ..-cs, ii Is ....".." ek„ ..........„ ...-- .......„.....--- it ■ • . 0 0 _'' -----1 lig 41•10/ G- B.PL. ... f eK el; 4}' io 5 . Ia. • ... ' • • • • .• 4 • *: .... .. , , •• • • " • • • • - . : io '- [NI "T" POST COL. "L" POST COL. B.PL. 11111 I ' 1/4 R IVET L.A. RR. #25534 14 GA. 2-1/4"0 ANCHOR BOLTS 1-1/4"o ANCHOR BOLT SEE NOTE NO. 3 ASTM A-502 DOUBLE RIVET DOUBLE RIVET BEAM 14 GA. 14 GA. LOW PROFILE POST C BEAM CONNECTION BEAM CONNECTION BASE PLATE DETAIL (FIXED SHELVING) 1 . <1 D D V V ,..•:.%. .0. 4 .3 g q 10-4V 4 4 t t O l ' I r>1. g .3 4 g D 4 4 p ANTI-TIP ARM 12 TEK SCREWS 2 PER ARM . ... im. 1 1/8" 1" THICK PLASTIC BRAKE SPACER CORNER BRACE 1/4"0 TEK SCREW EACH SIDE OF POST OR TO THE POST II . 1 SHELVING BEAM . EXISTING ST ... PRESS WITH FOOT TO SET 0 OBER STOP f Co r-, 4 .. ,,,c■ e SHELVING POST CONNECTED TO CARRIAGE - 9? WITH (2)-1/4"0 TEK SCREWS PER POST „", " I A WALL. STUD SPACER AS PRESS WITH FOOT TO RELEASE 0 .1 STOP RUBBER TOP SCREW sem \ . c'P --z- _ . -- - V , V n v c, v it D , v , v , „ , 0 , ..„ 1 /01:11_,. tc.4.' ..T.„ .. ,„: ;,,, '•■ ../ ).- ....„,. ,-, co REQUIRED SHELVING BEAM - • 1 1/4"o TEK SCREW ¢ ,. ._.i _1 a n 1- c cn w `---- ../ itAasi 'L__:' ED I- 4 ••..• : ' • • • .7 s • i=, .- . .• . - _ 4 7/8" . .. ' . •• , - '-• ,..• • • ;•. -•-• • , , • • . . • - • :. ' . BOTTOM SCREWS fi -1. . t1D ,., 0 ' ...- . v 1 o .11 ..':.u, i .. . • . . • a . . 1/4"o ANCHORS 2" EMB. 24" o.c. (SEE NOTE NO. . • . • . - 1 ' • •:•, : • ' • 3) C. ■- . . ii . • • • • • • ... :,.."1- ... , - -'. ' • ... . — FRONT VIEW SIDE VIEW SECTION A-A WALL CONN. CARRIAGE AND TRACK ASSEMBLY SECTION A—A FOOT BRAKE 5 p3 0 , p0 / s. . NOTES: g 1-DESIGN OF STEEL AND CALCULATIONS OF THE IBC 2008 2 FOR ALL SHAPES 3-ALL ANCHORS HILT! (NO SPECIAL INSPECTION 4 - SELVING CAPACITY 5-ALL SHELVING INSTALLATIONS WITH THIS STANDARD A PERMANENT PLAQUE SHOWING THE MAXIMUM -- n fo COV9 Oa AkP 0 7141) ,- P . 2.03 piy 1 A. ti\A‘ CM 1.0 " SU STORAGE SHELVING AS SHOWN BY THESE DRAWINGS ARE IN COMPLIANCE WITH THE REQUIREMENTS EDITION FY=36 KSI. ASTM A570-85 GR.36 (EXCEPT AS NOTED) KWIK BOLT-3 (ESR -1385) OR APPROVED EQUAL REQUIRED) 50 # / LEVEL AND SHELVING MANUFACTURED IN CONFORMITY SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS EACH NOT LESS THAN 50 SQUARE INCHES IN AREA PERMISSIBLE UNIT LOAD OF 50 # / LEVEL I) 0 anv 1 ( 3 RECEIVED CITY OF TUKWILA APR 0 1 1008 _,14 • "I PERMIT CENTER 17'-0" • 21'-6" 1/4 RIVET A 6'-5 1 / 4 " 5'-o" 12l-2" 11 HANGBAR alln= „1 . co I 0 „ IV 18" s 7. co ,- t■ .4 0, :P. --- -- , . 0 0 ' • - - . 4 •.■ N ., 4s" 1s" 18" 48" - - 4 0 . .4 .21 P : ...4 .. .4 HANGBAR . C 11 • F0-8 F0-3 r -- I G # 18 " @ -- 25 '" 1 ¢ > Y _1 r. r - - - • - - 111..:r ., •"" 48" 18" di t ' In 1 in . ? I 3 1 7 0 ® 11 0 i § I I r 01 d 1 TYP. U.N.O. / 0 TYP. TYP. 1/4 BOLTS 2 PLACES 0 ■•••■•■11 .•••■1 - 11 IIII 1/4"o BOLTS 2 PLACES 0 , - 4 0 ... (I) A _1 -...--- . -[--- -01 -- - STAGING AREA 3' -7 1/2" 0 . 0 - e is e , --"N Mil INN . ,, . • -I i e 0 ' , , .-• 0 REV. DATE REVISION 0 17'-0" STOCKROOM 1 1 , 1 1 - ., 1 J 0 , 0 1 ,a1( 0114 A ' - o%? WA sp,...: V,;''' .. _ TA: c -. .!-: - RACK DESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 ■■•■•••III NI 0 SQ. FT.: 388 FLOORING: 1 FC-3 I ;II! 01 st LEVEL . 0 ,- ak SCALE: NONE DRAWN BY: A.KH. DATE: 3-20-08 riliMM■11M411 liza-mmilmr• _ 9 Jt n B . • . . . • A4 1 -• 4t4s5r -1.:P ' PROJECT: G Y M B D R E E 1056 SOUTHCENTER MALL, TUKWILA, WA. 98188 __ ___ . _ __ __ , ----- _ _ HANG UNITS SIDE VIEW MOBILE FOLD UNITS MOBILE HANG UNITS . SHELVING LAYOUT , 5 ,..r . \-\ c>\'' STORAGE SHELVING DETAILS JOB NO. RD-13116 SHEET NO. A•1 EXPIRES 12-26-09