Loading...
HomeMy WebLinkAboutPermit D08-174 - WESTFIELD SOUTHCENTER MALL - FINISH LINE - STORAGE RACKSFINISH LINE 1017 SOUTHCENTER MALL D08 -174 Parcel No.: 6364200010 Address: 1017 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: FINISH LINE Address: 1017 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: DESCRIPTION OF WORK: INSTALLATION OF RACK FOR STORAGE AND STOCKS doc: IBC -10/06 City0f Tukwila • DEVELOPMENT PERMIT Contact Person: Name: ELMER JONES Address: 1154 PARKS INDUSTRIAL , VAN WEEGRIFF PA 15690 Phone: 724 882 -4431 Contractor: Name: ALLEGHENY DESIGN MANAGEMENT Address: 1154 PARKS INDUSTRIAL DR , VANDERGRIFT PA 15690 Phone: 724 - 845 -7336 Contractor License No ALLEGDM0300H Value of Construction: $0.00 Fees Collected: $536.63 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: 0019 * *continued on next page ** Permit Number: D08 - 174 Issue Date: 04/22/2008 Permit Expires On: 10/19/2008 Expiration Date: 01/10/2010 D08 -174 Printed: 04 -22 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City dinukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Permit Number: D08 - 174 Issue Date: 04/22/2008 Permit Expires On: 10/19/2008 Date: �� t/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: «�� Date: Print Name: C` 2- - z'w es This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D08 -174 Printed: 04 -22 -2008 City of Tukwila Parcel No.: 6364200010 Address: 1017 SOUTHCENTER MALL TUKW Suite No: Tenant: FINISH LINE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -174 Status: ISSUED Applied Date: 04/08/2008 Issue Date: 04/22/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done m conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *FIRE DEPARTMENT CONDITIONS * ** 8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 9: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 10: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 11: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 12: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 13: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D08 -174 Printed: 04 -22 -2008 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 ,014 Q�/J�' Date: :,._ L —2—Otce 5 D08 -174 Printed: 04 -22 -2008 Site Address: Tenant Name: Property Owners Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.eLtukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION /d /7 Se u. c:l 4-4,7k /1bSL ame: J c '- S w tr_L�4 Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. /j6 GO,LShi'R iSLua Los Les City (For office use only) ftl -0( King Co Assessor's Tax No.: /L41/0 0010 t L &/C kJ Suite Number: /y 2 Floor: New Tenant: .... Yes ..No w" 2 L LC State 70 ,z 5 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Eh°!f-r -- c � rte -C.'-5 Day Telephone: 7A 9- T e' 2 - ) 9 3l Mailing Address: i f 51/ ?r r kS :IA 'C1 �4-.S 1Ky k, V, ti Opt> 1,‘ P Po . / .s C 1/ 0 City State Zip E -Mail Address: C T ces Q .ieiv)� lac ?S , .,t, iyl9 M j FF,,,px Number: 7 7 — S 9 Ts-- 9 I GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Pl� r9- 'v/91e /hekv 0 if N 00 w , r/ /�, /3 t `1 t2 City State Zip Day Telephone: '7 - -- t/ ! 3 / Fax Number: 1, 7 L.(-1 - 6 Li Ste- 5"F Expiration Date: 0/Pc/ 0 / c� Company Name:' " L,1 e e -/ CC . Ce9 ti Mailing Address: l 151 �" P4. kS ; Contact Person: 6/vo. C+.^ E -Mail Address: Contractor Registration Number: / LL_ ec? D M C2 3 C' C) ri ►/ 5 ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Q \Applications\Forms - Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh State ENGINEER OF RECORD — All plans must be roped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip Zip Page 1 of 6 BUILDING PERMIT INFORM TION - 206- 431 -3670 Valuation of Project (contractor's bid price): / /4 W, '' Scope of Work (please provide detailed information): Will there be new rack storage? A.... Yes , r Existing Building Valuation: $ .' k5' 1` i n F s` �� ^� i-- S - E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ^ 1 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) (/ Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: \ Applications \Forms-Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 2' Floor 3' Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORM TION - 206- 431 -3670 Valuation of Project (contractor's bid price): / /4 W, '' Scope of Work (please provide detailed information): Will there be new rack storage? A.... Yes , r Existing Building Valuation: $ .' k5' 1` i n F s` �� ^� i-- S - E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ^ 1 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) (/ Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: \ Applications \Forms-Applications On Line' -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT Signature: Print Name: /L. Me - ��, ,, c Mailing Address: //5 /43- lc, , /WU 0 Date Application Accepted: a�l Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: Date: ) Day Telephone: 72 y.- 8-.2-5/y 'J 094, / City State Zip Staff Initials: Page 6 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or ater cooler (per head) f Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial ,/ Receptor, indirect waste Clothes washer, domestic Floor drain inks Dental unit, cuspidor Shower, si a head trap finals Dishwasher, domestic, with independent drain Lavatory ,r er Closet Building sewer or trailer park sewer Rain ater system — per draip (inside building) Water . ater and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors R air or alteration of water ping and /or water treating 'equipment Repair or .. eration of drainage • vent piping Medical gas piping system serving one to five inlets /outlets for specific gas Contact Person: E -Mail Address: Contractor Registration Number: Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Valuation of Plumbin work (contractor's bid price): $ Valuation of Gas Piping ork (contractor's bid price): $ Scope of Work (please prov ' e detailed information): Indicate type of plumbing fixtures and /or gas piping o Q:\Applicationsworms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: PLUMBING AND GAS PIPING PERMIT INFORMATION 206- 431 -6670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: eing installed and the quantity below: State Zip Page 5 of 6 Parcel No.: 6364200010 Permit Number: D08 -174 Address: 1017 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/08/2008 Applicant: FINISH LINE Issue Date: Receipt No.: R08 -01067 Initials: JEM User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us Payee: ALLEGHENY DESIGN MANAGEMENT, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 81089 536.63 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $536.63 Payment Date: 04/08/2008 09:34 AM Balance: $0.00 322.50 209.63 4.50 Total: $536.63 e925 0 '711 TOTAL 536.5 doc: Receiot -06 Printed: 04 -08 -2008 Proje /ev/s . e'Nr Type of I /NA? / r' A /0% 7/ Date Called: Special Instructions: Date anted: a. Requester: Phone No: j `72 « - 8, - z4T3 / r. • INSPECTION RECORD Retain a copy with permit D4 g"-/ / INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f47 R Approved per applicable codes. Corrections required prior to approval. COMMENTS: (Inspector: Date: 6 ❑ $60.00 R INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: Project: . M 5 k 1- .,‘ry -�. Sprinklers: Fire Alarm: Type � of Inspection: f H- 4.. Address: 1 0 1-7 s Suite #: m- t_.- Contact Person: rt ... os%- S Special Instructions: Phone No.: Needs Shift Inspect ion: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Wool. ,i3O+, Inspector: INSPECTION NUMBER 444 Andover Park East. Tukwila. Wa. 98188 206- 575 -4407 proved per applicable codes. COMMENTS: - cow ktde L Hrs.: • l y� n 5.80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc INSPECTLON RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT tDate: b/9/ - I .. DeV - I ‘7y PERMIT NUMBERS. Corrections required prior to approval. 1/13/06 T.F.D. Form F.P. 113 • -. Vg MZ, - June 13, 2008 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION Mr. Elmer Jones Allegheny Design Management, Inc. 1154 Parks Industrial Drive Vandergrift, PA 15690 -9666 RE: Special Inspection Finish Line Tukwila, WA Dear Mr. Jones, Respectfully submitted, KRAZAN & ASSOCIATES, INC Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila 2LZJ1TI & ASSOCIATES, INC. Receiv �11 3 p 2008 oce O Y Offices Serving The Western United States KA No. 066 - 08073 Permit Noy-P(46-245- 10$-17` In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors from June 5 trough June 6, 2008. Copies of our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 - 2556 08073 DFR Template 'aZ l & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: OP -ea/8 PROJECT #: "Oed Xr y PROJECT: /'4.6.i€ , G /OlT LOCATION: 03All 3./O4- KRAZAN PROJECT MANAGER: CONTRACTOR: 1 - - heat AQ ak/ JURISDICTION: �� PERMIT #: ,d 48- /7�T INSPECTOR: $ 4" WEATHER:abey TEMP: v. 5f ' E quipment/Asset Number(s): To the best of my knowledge, the above W Superintendent /Representative: performed in accordance with The approved plans, specifications, and regulatory requirerr Technic Serving the Western Uni FIELD REPORT NO: 8 0 3 9 0 d States Ge i t2✓ / 1501 Field Repon.doc Revision I Effective Date: SRS /OS The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. a aZ & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: /,& CONTRACTOR: PROJECT #: 'gee?? > JURISDICTION: PROJECT: /51.4,7 #0' e. /D / PERMIT #: e � LOCATION: l d �a let., INSPECTOR: WEATHER: KRAZAN PROJECT MANAGER: 1501 Field Report.doc Superintendent /Representative: FIELD REPORT NO: 8 03 9 5 i ■ ZIII0 '-1. " / /. S' ♦.a0 / . C /.s 4' 1 s ' 1 '4/ 0 ' lo .• /r/ -44 ' I . L / 4) 133 K6 1Z 3/R X 3 ..Y41 ltiec,e Anchor -- 6otis Adestv, p o foc ( Q krawe∎ vriPk.1I1 - � � � ie z= Fz, 3 E1 /.2..32. 6�!' Ent 1 ,Z3_3 � �'.� ~ / �.23 -24,3 ( ekrvt) 491 ij.4 i e . clem.►i1 i'�1!' bw.5ki.►.4 6.11.11— V& CA " 3) I/Yet✓ e►.v,n .s Ir f L&c ash-- c,V e te. aw. aw bio.H- Intr►% der- • Equipment/Asset Number(s): To the best of my knowledge, the abo WA NVAS NOT performed in accordance with the approved plans, specifications, and regulatory requireme Techni Serving the Western Uni -d States Revision 1 Effective Date: 5/5/05 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. PLE COP PerMit Na R Project Name : Finish Line #896 Project Number : G-112607-11 Date: 11/27/07 Street Address : 633 Southcenter Mall, Space 1425 City/State: Tukwila, WA 98188 Scope of Work : Shelving oncepts ngineering 1200 N. Jefferson St, Suite F Anaheim, GA 92807 Tel: 714.032.7330 Fax: 714.0327703 e-mail: mall@sceinc.net NOV 2 9 2007 RECEIVED CITY OF TUKWIIA APR 0 8 7008 PERMIT CENTER IRES 10/25771 NOV 2 7 2007 Structural Analysis Based on the 2006 International Building Code Project: Finish Line Store #896 Location: Southcenter Mall (Space #1425) 633 Southcenter Mall Tukwila, WA 98188 General Parameters 1 - 4 Static Loads 5 Static Column Analysis 6 - 8 Seismic Lateral Force Calculation 9 Seismic Force Distribution 10 - 11 Seismic Column Analysis 12 - 14 Bolt Spacing for Composite Action 15 Sway Brace Analysis for Seismic Loading 16 - 18 36" Wide X 12" Deep Shelf Analysis 19 - 20 48" Wide X 12" Deep Shelf Analysis 21 - 22 Base Plate & Anchor Bolt Analysis 23 - 25 Shelving Post Section Properties 26 - 27 Seismic Parameters 28 Republic Storage Systems Company, LLC 1038 Belden Avenue NE • Canton, OH 44705 Phone (330) 428 -5800 • Fax (330) 454 -7772 Pages Item Weight Each Total Qty. Portion Applied Total Weight Angle Post - 121" 6.40 4 1 _ 25.60 Shelf - 36" x 12" x 20ga 6.50 6 1 39.00 Side Brace 0.70 6 1 4.20 Back Brace 1.20 4 1 4.80 0.00 0.00 0.00 0.00 Item Weight Each Total Qty. Portion Applied 1 Total Weight _ 25.60 Angle Post - 121" 6.40 4 Shelf - 48" x 12" x 20ga 8.90 6 1 53.40 Side Brace 0.70 6 1 4.20 Back Brace 1.40 4 1 5.60 0.00 0.00 A B C D 12 12 12 12 36 48 48 48 121.0 121 121.0 121 DA DA DA DA SA SA SA DA Job Name: Finish Line Location: Tukwila, WA Order # 796529 Shelving Unit Parameters; Elevation: Unit Depth = Unit Width = Unit Height = Intermediate Post: Row End Post: Elevation A - Dead Load per Unit; Elevation B - Dead Load per Unit; DA = Double Angie Post SA = Single Angle Post Page: 1 By: LJS Date: 11/20/07 Item Weight Each Total Qty. Portion Applied Total Weight Angle Post - 121" 6.40 4 1 25.60 Shelf - 48" x 12" x 20ga 8.90 8 1 71.20 Side Brace 0.70 6 1 4.20 Back Brace 1.40 4 1 5.60 U 121 7 0.00 0.00 8 8 0.00 0.00 Item Weight Each Total Qty. Portion Applied Total Weight_ 25.60 Angle Post - 121" 6.40 4 1 Shelf - 48" x 12" x 20ga 8.90 3 1 26.70 Side Brace 0.70 6 1 4.20 Back Brace 1.40 4 1 5.60 6 U 121 7 0.00 8 8 0.00 Story Level Story Type Elevation Shelf Load 1 L 4 100 2 L 28 100 3 L 52 100 4 L 76 100 5 L 100 100 6 U 121 7 7 8 8 9 9 10 10 Story Level Story Type Elevation 4 Shelf Load 1 L 100 2 L 28 100 3 L 52 100 4 L 76 100 5 L 100 100 6 U 121 7 8 9 10 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Elevation C - Dead Load per Unit; Shelf Levels: Elevation A Elevation D - Dead Load per Unit; L = Loaded Shelf Level U = Unloaded Shelf Level Elevation B Page: 2 By: LJS Date: 11/20/07 Story Level Story Type Elevation Shelf Load 1 L 4 100 2 L 20.5 100 3 L 37 100 4 L 53.5 100 5 L 70 100 6 L 86.5 100 7 L 103 100 8 U 121 9 10 Story Level Story Type Elevation Shelf Load _ 1 U 4 0 2 L 62.5 100 3 L 121 100 4 4 4 4 5 6 7 8 9 10 A B C D 0 0 0 0 1 1 1 1 4 4 4 4 4 4 4 4 1 1 1 1 2 2 2 2 24 24 16.5 58.5 24 24 16.5 58.5 A B C D 12.3 14.8 13.3 20.7 100.0 100.0 100.0 0.0 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Elevation C Shelf Loads: Job Name: Finish Line Location: Tukwila, WA Order # 796529 Seismic Information; Post Analysis; Elevation: Shelf Dead Load = Shelf Live Load = Post Analysis #1: Elevation: Check Post Between Shelf Level: Shelf Level: Lx = Ly = Post Analysis #2: Check Post Between Shelf Level: Shelf Level: Lx = Ly = Zip Code: S = S, = F = F„ = 98188 1.428 0.489 1.000 1.511 Elevation D 9 9 Site Class D Site Class D ** Shelf Level 0 is the Floor! *` Page: 3 By: LJS Date: 11/20/07 Lbs. Lbs. Page: 3 By: LJS Date: 11/20/07 Job Name: Finish Line Page: 4 Location: Tukwila, WA By: LJS Order # 796529 Date: 11/20/07 Results: Pmin & Pmax: Elevation = Static Loads: Post Analysis #1: Int. Post = Post Analysis #1: R.E. Post = Post Analysis #2: Int. Post = Post Analysis #2: R.E. Post = Seismic Loads: Post Analysis #1: Int. Post = Post Analysis #1: R.E. Post = Post Analysis #2: Int. Post = Post Analysis #2: R.E. Post = Int. Post, Pmax = R.E. Post, Pmax = Int. Post, Pmin = A 1 B I C 1 D 1 0.0632 1 0.0649 1 0.0889 1 0.0275 OK I 0.0632 1 0.0649 1 0.0889 I OK I 0.0745 1 0.0765 1 0.0894 1 0.0903 I OK I 0.0745 1 0.0765 1 0.0894 1 OK 1 0.1216 1 0.1262 1 0.1698 1 0.0649 I OK OK OK OK Seismic Seismic OK OK OK OK OK I 0.1216 1 0.1262 1 0.1698 OK I 0.1590 1 0.1651 1 0.1814 1 0.2187 I OK OK Seismic Seismic OK OK OK OK OK OK OK I 0.1590 1 0.1651 1 0.1814 I OK Seismic Seismic OK OK OK OK I 552.1 1 572.5 1 770.7 1 308.6 I Seismic I 276.0 1 286.3 1 385.4 1 154.3 1 Seismic I -160.7 1 -172.7 1 -218.5 1 -148.4 I Uplift Uplift Uplift Uplift R.E. Post, Pmin = I -80.3 1 -86.3 1 -109.2 1 -74.2 I Uplift Uplift Uplift Uplift A B C D 5 5 7 2 100.0 100.0 100.0 100.0 500.0 500.0 700.0 200.0 250.0 250.0 350.0 100.0 125.0 125.0 175.0 50.0 A B C D 73.6 88.8 106.6 62.1 36.8 44.4 53.3 31.1 18.4 22.2 26.7 15.5 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Elevation = Unit Load = Intermediate Post Load = Row End Post Load = Elevation = # Loaded Shelves = Average Shelf Load = Unit Load = Intermediate Post Load = Row End Post Load = Calculation of Shelving Dead Load Intermeidate Post Load = Unit Load / 2 Row End Post Load = Unit Load / 4 Calculation of Shelving Live Load Intermeidate Post Load = Unit Load / 2 Row End Post Load = Unit Load / 4 Lbs. Lbs. Lbs. Lbs. Lbs. Lbs. Lbs. Page: 5 By: LJS Date: 11/20/07 0 0 0 0 1 1 1 1 286.8 294.4 403.3 131.1 18.9 18.9 18.9 12.6 0.0632 0.0649 0.0889 0.0275 1 1 1 1 2 2 2 2 230.7 237.0 346.6 120.7 113.3 113.3 77.9 184.1 0.0745 0.0765 0.0894 0.0903 A B C D' 286.8 294.4 403.3 131.1 143.4 147.2 201.7 65.5 12.3 14.8 13.3 20.7 100.0 100.0 100.0 0.0 112.3 114.8 113.3 20.7 115.3 118.5 173.3 113.3 113.3 77.9 0.0745 0.0765 0.0894 143.4 147.2 201.7 18.9 18.9 18.9 0.0632 0.0649 0.0889 Job Name: Finish Line Page: 6 Location: Tukwila, WA By: LJS Order # 796529 Date: 11/20/07 Total Post Load Post Analysis; Elevation = Intermediate Post Load = Row End Post Load = Shelf Dead Load = Shelf Live Load = Total Shelf Load = Post Analvsis #1 - Check Post Between: Shelf Level = Y = Shelf Level = Intermediate Post Load, P = KL / R = Unity Check = Row End Post Load, P = KL / R = Unity Check = Post Analysis #2 - Check Post Between: Shelf Level = Z = Shelf Level = Intermediate Post Load, P = KL / R = Unity Check = Row End Post Load, P = KL / R = Unity Check = Post Loads OK OK OK OK OK OK Intermediate Post Load, P = Total Intermediate Post Load - Y x Total Shelf Load / 2 Row End Post Load, P = Total Row End Post Load - Y x Total Shelf Load / 4 OK OK OK OK OK OK Shelf Level 0 is the Floor. " OK OK * Double angle posts shall be used at row ends for Elevation D. Thus they will not control the design and shall not be analyzed. Lbs. Lbs. Lbs. Lbs. Lbs. <= 200 <= 1.0 <= 200 <= 1.0 <= 200 <= 1.0 <= 200 <= 1.0 Intermediate Post Load, P = Total Intermediate Post Load - Z x Total Shelf Load / 2 Row End Post Load, P = Total Row End Post Load - Z x Total Shelf Load / 4 0.1492 0.1492 0.1492 0.2985 0.0087 0.0087 0.0087 0.0301 0.011 0.011 0.011 0.0301 0.2119 0.2119 0.2119 0.3177 4 4 4 4 1.0 1.0 1.0 1.0 42 42 42 42 0.7 0.7 0.7 0.73 0.05 0.05 0.05 0.0999 0.0387 0.0387 0.0387 0.0774 0.5786 0.5786 0.5786 0.5786 4 4 4 4 1.0 1.0 1.0 1.0 0.075 0.075 0.075 0.075 18.88 18.88 18.88 12.59 6.91 6.91 6.91 6.91 18.88 18.88 18.88 12.59 117.75 117.75 117.75 117.75 426.30 426.30 426.30 958.27 3178.43 3178.43 3178.43 3178.43 0.961 0.987 1.352 0.439 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 25.200 25.200 25.200 25.200 N/A N/A N/A N/A 15.209 15.209 15.209 15.938 N/A N/A N/A N/A A B C D* SA SA SA DA 0.143 0.147 0.202 0.131 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Combined Loading for Static Loads; Elevation = Post Type = P= M = M = Section Properties; A = I = S. = R = L = K = F = Q= l = Sy = Ry = Ly = Ky = T= Analysis for Combined Stresses; (KL / R) = (KL / My = (KL / R)max = C = ex - F' = F = Fb = Fb = Fb = Faia = Falb = Falc = F =I 15.209 Unity Check; Unit Check = 15.209 1 15.209 15.938 0.0632 0.0649 1 0.0889 0.0275 kips in. -kips in. -kips in. in. in. in. in. ksi in.' in. in. in. in. <= 200 Page: 7 By: LJS Date: 11/20/2007 * Elevation D shall be analyzed using a double angle post. The single angles shall be attached together in order to obtain composite action. The calculations for bolt: spacing to be used for composite action are found on page 15. ksi = (12 n E) / {23 [(KL / R) ksi = (12 n E) / {23 [(KL / R) ksi = P / A ksi = M / S ksi = M / S ksi =0.6F ksi = 151900 / (KL / R) ksi = .522 Q F - [Q F (KL / R) / 1494] ksi = [1 - (KL /R) /(2 C F / {(5/3)+ [3 (KL / R) / (8 Cc)] - [(KL / R) / (8 C = (Fa / Fa1) + (.85 Fbx) / {[1 - (Fa / F'ex)] Fb} OK OK OK OK + (. 85 Fby) / {[1 - (Fa / Fey)] Fb} <= 1.0 0.1492 0.1492 0.1492 0.2985 0.0087 0.0087 0.0087 0.0301 0.011 0.011 0.011 0.0301 0.2119 0.2119 0.2119 0.3177 24 24 16.5 58.5 1.0 1.0 1.0 1.0 42 42 42 42 0.7 0.7 0.7 0.73 0.05 0.05 0.05 0.0999 0.0387 0.0387 0.0387 0.0774 0.5786 0.5786 0.5786 0.5786 24 24 16.5 58.5 1.0 1.0 1.0 1.0 0.075 0.075 0.075 0.075 113.26 113.26 77.87 184.14 41.48 41.48 28.52 101.11 113.26 113.26 77.87 184.14 117.75 117.75 117.75 117.75 11.84 11.84 25.05 4.48 88.29 88.29 186.79 14.86 0.773 0.794 1.162 0.404 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 25.200 25.200 25.200 25.200 N/A N/A N/A 4.480 10.379 10.379 12.999 N/A N/A N/A N/A N/A A B C D* SA SA SA DA 0.115 0.119 0.173 0.121 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Combined Loading for Static Loads; Elevation = Post Type = P= M = M = Section Properties; = I = Sx = R = L = K = Fy = Q= l = S = R = L = K = T= Analysis for Combined Stresses; (KL / R) = (KL / R) = (KL / R)max = C = Fax = F' = F = Fbx = Fb = Fb = Faia = Falb = Faic = Fat = Unity Check; Unit Check = 10.379 1 10.379 1 12.999 4.480 0.0745 1 0.0765 0.0894 1 0.0903 kips in. -kips in. -kips in. in. in. in. in. ksi in. <= 200 ksi = (12 n E) / {23 ksi = (12 7E / {23 ksi =P /A ksi = M / S ksi = M / S ksi = 0.6 F ksi = 151900 / (KL / ksi = .522 Q F - [Q ksi = [1 - (KL / R) / [3 (KL / R) / (8 C - Page: 8 By: LJS Date: 11/20/2007 * Elevation D shall be analyzed using a double angle post. The single angles shall be attached together in order to obtain composite action. The calculations for bolt spacing to be used for composite action are found on page 15. [(KL / R) [(KL / R) R) 2 F (KL / R) / 1494] (2 Cc2)] F / {(5 / 3) + [(KL / R) (8 C = (Fa / Fa1) + (.85 Fbx) / {[1 - (Fa / F'ex)] Fb} OK OK OK OK + (.85 Fby) / {[1 - (Fa / F'ey)] Fb} <= 1.0 A B C D 73.6 88.8 106.6 62.1 500.0 500.0 700.0 200.0 408.60 423.80 575.60 196.10 69.46 72.05 97.85 33.34 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Calculation of Seismic Lateral Load 2006 International Building Code Site Ground Motion Parameters Based on Section 1613.5; Zip Code: 98188 S = 1.428 S = 1.428 g SDS = 0.952 S = 0.489 g SM, = 0.739 F = 1 Site Class D SD, = 0.493 F„ = 1.511 Site Class D Ts = 0.5174 Occupancy Category = Seismic Design Category = Lateral Force Based on Section 1613; Per section 1613.1 of the 2006 IBC, lateral load may be determined using ASCE 7 -05. be calculated using Sections 12.8, 15.4 & 15.5 of ASCE 7 -05. V= CON R = 4.0 1= 1.00 T = C h„ 314 CT = h = = 0.11317 sec. Cs= 0.2380 = Sips / (R /I) C 1.0882 = S /(R /I)T C = 0.0100 C N/A = 0.8S /R Elevation = Int. Post Line D.L. = Int. Post Line S.L.L. = W= V= 1 (1,11, III, or IV) per Table 1604.5 D (A,B,C,D,E or F) per Section 1613.5.6 0.02 10.1 (Eqn. 12.8 -1) (Section 15.5.3.1) (Table 11.5 -1) (Eqn. 12.8 -7) (Table 12.8 -2) Overall Height in ft. (Eqn. 12.8 -2) (Eqn. 12.8 -3) (Eqn. 12.8 -5) (Eqn. 15.4 -2) C = 0.2380 (Eqn. 12.8 -2) g =FaSs g = (2/3) SMs g =F g = (2/3) SM, = SD1 /SDS Need Not Exceed Value Not Less than Value Not Less than Value for S, >= 0.6g Controls The lateral Toad shall W = Dead Load + 67% Shelf Live Load (Section 15.5.3.2) V =C / 1.4 (Using Allowable Reduction for ASD Design Method. 2006 IBC Eqn. 16 -20) Lbs. Lbs. Lbs. Lbs. = Cs W / 1.4 Page: 9 By: LJS Date: 11/20/07 (Eqn. 16 -37) (Eqn. 16 -39) (Eqn. 16 -38) (Eqn. 16-40) (ASCE 7 -05 Section 11.4.5) STORY NUMBER i STORY ELEV. hi (in.) STORY LOAD Wi (Lbs.) Wi x hi BASE SHEAR V (Lbs.) STORY SHEAR V x Wi x hi /E(Wi x hi) Fi (Lbs.) BASE MOMENT Fi x hi (in -Lbs) SHEAR SUM EFi (Lbs.) STORY MOMENT Mi (in -Lbs) (O I) V (+) N 1- 0 121 14.80 1791 72.05 5.60 677.03 5.60 0.00 100 81.80 8180 72.05 25.56 2555.80 31.15 117.50 76 81.80 6217 72.05 19.42 1476.23 50.58 865.18 52 81.80 4254 72.05 13.29 691.09 63.87 2079.03 28 81.80 2290 72.05 7.16 200.37 71.02 3611.85 4 81.80 327 72.05 1.02 4.09 72.05 5316.42 0 0.00 0 72.05 0.00 0.00 72.05 5604.60 TOTAL = 23059 72.05 5604.60 STORY NUMBER i STORY ELEV. hi (in.) STORY LOAD Wi (Lbs.) Wi x hi BASE SHEAR V (Lbs.) STORY SHEAR V x Wi x hi /E(Wi x hi) Fi (Lbs.) BASE MOMENT Fi x hi (in -Lbs) SHEAR SUM EFi (Lbs.) STORY MOMENT Mi (ice -Lbs) -Lbs) co iO V r) N .- 0 121 12.27 1484 69.46 4.67 564.65 4.67 0.00 100 79.27 7927 69.46 24.92 2492.13 29.59 98.00 76 79.27 6024 69.46 18.94 1439.46 48.53 808.11 52 79.27 4122 69.46 12.96 673.87 61.49 1972.78 28 79.27 2219 69.46 6.98 195.38 68.47 3448.47 4 79.27 317 69.46 1.00 3.99 69.46 5091.63 0 0.00 0 69.46 0.00 0.00 69.46 5369.48 TOTAL = 22094 69.46 5369.48 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Distribute V per the following Equation Elevation A Elevation B F = W, xhk/ E(W Page: 10 By: LJS Date: 11/20/07 where k = 1.0 STORY NUMBER i STORY ELEV. hi (in.) STORY LOAD Wi (Lbs.) Wi x hi BASE SHEAR V (Lbs.) STORY SHEAR V x Wi x hi /E(Wi x hi) Fi (Lbs.) BASE MOMENT Fi x hi (in -Lbs) SHEAR SUM EFi (Lbs.) STORY MOMENT Mi (in -Lbs) CO h (O (n V' r) N ,- O 121 13.33 1612 97.85 4.98 602.32 4.98 0.00 103 80.33 8273 97.85 25.54 2630.98 30.52 89.60 86.5 80.33 6948 97.85 21.45 1855.56 51.97 593.20 70 80.33 5623 97.85 17.36 1215.18 69.33 1450.76 53.5 80.33 4297 97.85 13.27 709.82 82.60 2594.75 37 80.33 2972 97.85 9.18 339.51 91.78 3957.65 20.5 80.33 1647 97.85 5.08 104.22 96.86 5471.96 4 80.33 321 97.85 0.99 3.97 97.85 7070.15 0 0.00 0 97.85 0.00 0.00 97.85 7461.55 TOTAL = 31694 97.85 7461.55 STORY NUMBER i STORY ELEV. hi (in.) STORY LOAD Wi (Lbs.) Wi x hi BASE SHEAR V (Lbs.) STORY SHEAR V x Wi x hi /E(Wi x hi) Fi (Lbs.) BASE MOMENT Fi x hi (in -Lbs) SHEAR SUM EFi (Lbs.) STORY MOMENT Mi (in-Lbs) M N ,- O 121 87.70 10612 33.34 21.87 2646.26 21.87 0.00 62.5 87.70 5481 33.34 11.30 706.03 33.17 1279.39 4 20.70 83 33.34 0.17 0.68 33.34 3219.62 0 0.00 0 33.34 0.00 0.00 33.34 3352.97 TOTAL = 16176 33.34 3352.97 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Distribute V per the following Equation; Elevation C Elevation D F, = W E(W,xhk) Page: 11 By: LJS Date: 11/20/07 where k = 1.0 A B C D* 286.8 294.4 403.3 131.1 5369.5 5604.6 7461.6 3353.0 12 12 12 12 447.5 467.1 621.8 279.4 734.3 761.5 1025.1 410.5 1 1 1 1 2 2 2 2 655.0 680.0 935.8 389.0 113.3 113.3 77.9 184.1 0.1590 0.1651 0.1814 0.2187 0 0 0 0 1 1 1 1 734.3 761.5 1025.1 410.5 18.9 18.9 18.9 12.6 0.1216 0.1262 0.1698 0.0649 12.3 14.8 13.3 20.7 100.0 100.0 100.0 0.0 112.3 114.8 113.3 20.7 367.1 380.7 512.5 18.9 18.9 18.9 0.1216 0.1262 0.1698 327.5 340.0 467.9 113.3 113.3 77.9 0.1590 0.1651 0.1814 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Total Post Load; Post Analysis; Elevation = Intermediate Post Load = Overturning Moment = Shelf Depth = Seismic Load = +/- Intermediate Post, Pmax = Row End Post, Pmax = Intermediate Post, Pmin = Row End Post, Pmin =I Shelf Dead Load = Shelf Live Load = Total Shelf Load = Post Analysis #1 - Check Post Between: Shelf Level = Y = Shelf Level = Intermediate Post Load, Ps = KL /R= Unity Check = Row End Post, Ps Load = KL / R = Unity Check = Post Analysis #2 - Check Post Between: Shelf Level = Z = Shelf Level = Intermediate Post Load, Ps = KL /R= Unity Check = Row End Post, Ps Load = KL /R= Unity Check = Seismic Post Loads 367.1 380.7 512.5 205.2 -160.7 1 -172.7 1 -218.5 1 -148.4 Uplift -80.3 Uplift Pmax = Post Load + Seismic Load Pmin = Post Load - Seismic Load OK Uplift -86.3 1 Uplift OK Uplift -109.2 Uplift OK Uplift -74.2 (Lbs. Uplift OK OK OK OK Intermediate Post Load, Ps = Intermediate Post Load + Seismic Load - Y x Total Shelf Load / 2 Row End Post Load, Ps = Row End Post Load + Seismic Load - Y x Total Shelf Load / 4 OK OK OK ** Shelf Level 0 is the Floor. ** OK * Double angle posts shall be used at row ends for Elevation D. Thus they will not control the design and shall not be analyzed. Lbs. in. -Lbs. in. Lbs. Lbs. Lbs. Lbs. Lbs. Lbs. Lbs. <= 200 <= 1.0 <= 200 <= 1.0 <= 200 <= 1.0 <= 200 <= 1.0 OK OK OK Intermediate Post Load, Ps = Intermediate Post Load + Seismic Load - Z x Total Shelf Load / 2 Row End Post Load, Ps = Row End Post Load + Seismic Load - Z x Total Shelf Load / 4 Page: 12 By: LJS Date: 11/20/07 Uplift 0.1492 0.1492 0.1492 0.2985 0.0087 0.0087 0.0087 0.0301 0.011 0.011 0.011 0.0301 0.2119 0.2119 0.2119 0.3177 4 4 4 4 1.0 1.0 1.0 1.0 42 42 42 42 0.7 0.7 0.7 0.73 0.05 0.05 0.05 0.0999 0.0387 0.0387 0.0387 0.0774 0.5786 0.5786 0.5786 0.5786 4 4 4 4 1.0 1.0 1.0 1.0 0.075 0.075 0.075 0.075 18.88 18.88 18.88 12.59 6.91 6.91 6.91 6.91 18.88 18.88 18.88 12.59 117.75 117.75 117.75 117.75 566.98 566.98 566.98 1274.50 4227.31 4227.31 4227.31 4227.31 2.461 2.552 3.435 1.375 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 33.516 33.516 33.516 33.516 N/A N/A N/A N/A 20.228 20.228 20.228 21.197 N/A N/A N/A N/A A B C D" SA SA SA DA 0.367 0.381 0.513 0.410 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Combined Loading for Seismic Loads; Elevation = Post Type = P= M = M = Section Properties; A I.= Sx = R = L = K = F = Q= l S = R = L = K = T= (KL /R) (KL / R) = (KL / R)max = C = Fax = F = F = Fbx = Fb = Fb = Fala = Falb = Falb = Fai = Unity Check Unit Check = Analysis for Combined Stresses Using 33 -113% Stress Increase for Seismic; 20.228 1 20.228 20.228 21.197 1 0.1216 1 0.1262 1 0.1698 1 0.0649 kips in. -kips in. -kips in. in. in. in. in. ksi in. <= 200 Page: 13 By: LJS Date: 11/20/2007 * Elevation D shall be analyzed using a double angle post. The single angles shall be attached together in order to obtain composite action. The calculations for bolt spacing to be used for composite action are found on page 15. ksi = 1.33 (12 n E) / {23 [(KL / R)0 ksi = 1.33 (12 n E) / {23 [(KL / R)0 ksi =P /A„ ksi = M / S ksi = M / S ksi = 1.33 (0.6 F ksi = 1.33 [151900 / (KL / R) ksi = 1.33 (.522 Q Fy - [Q Fy (KL / R) / 1494] ksi = 1.33 {[1 - (KL / R) / (2 C F / {(5 / 3) + [3 (KL / R) / (8 C - [(KL / R) (8 C }} = (Fa / Fa1) + (.85 Fbx) / ([1 - (Fa / F'ex)] Fb} OK OK OK OK + (.85 Fby) / {[1 - (Fa / F'ey)] Fb) <= 1.0 0.1492 0.1492 0.1492 0.2985 0.0087 0.0087 0.0087 0.0301 0.011 0.011 0.011 0.0301 0.2119 0.2119 0.2119 0.3177 24 24 16.5 58.5 1.0 1.0 1.0 1.0 42 42 42 42 0.7 0.7 0.7 0.73 0.05 0.05 0.05 0.0999 0.0387 0.0387 0.0387 0.0774 0.5786 0.5786 0.5786 0.5786 24 24 16.5 4 1.0 1.0 1.0 1.0 0.075 0.075 0.075 0.075 113.26 113.26 77.87 184.14 41.48 41.48 28.52 6.91 113.26 113.26 77.87 184.14 117.75 117.75 117.75 117.75 15.75 15.75 33.32 5.96 117.43 117.43 248.44 4227.31 2.195 2.279 3.136 1.303 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 33.516 33.516 33.516 33.516 N/A N/A N/A 5.958 13.804 13.804 17.288 N/A N/A N/A N/A N/A A B C D* SA SA SA DA 0.327 0.340 0.468 0.389 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Job Name: Finish Line Page: 14 Location: Tukwila, WA By: LJS Order # 796529 Date: 11/20/2007 Combined Loading for Seismic Loads; Elevation = Post Type = P= M = My = Section Properties; A = Ix = S = R = L = K = F = Q = I = Sy = Ry = Ly = Ky = T= Analysis for Combined Stresses Using 33 -113% Stress Increase for Seismic; (KL / R) = (KL / R) = (KL / R)max = C = F = F' = F = Fbx = F = F = Fala = Falb = Fa lc = F31 = I 13.804 1 13.804 1 17.288 I 5.958 Unity Check Unit Check =I 0.1590 1 0.1651 1 0.1814 OK OK OK 0.2187 kips in. -kips in. -kips in. in. in. in. in. ksi in. in. in. in. in. <= 200 * Elevation D shall be analyzed using a double angle post. The single angles shall be attached together in order to obtain composite action. The calculations for bolt spacing to be used for composite action are found on page 15. ksi = 1.33 (12 n E) / {23 [(KL / R) ksi = 1.33 (12 11 E) / {23 [(KL / R)0 ksi =P /A„ ksi = M / S ksi =M /S ksi = 1.33 (0.6 F ksi = 1.33 [151900 / (KL / R) ksi = 1.33 {.522 Q F - [Q F (KL / R) / 1494] ksi = 1.33 {[1 - (KL / R) / (2 Cc2)] F / {(5 / 3) + [3 (KL / R) / (8 C - [(KL / R) / (8 C }} = (Fa / Fa1) + (.85 Fbx) /ID - (Fa / F'ex)] Fb} OK + (.85 Fby) / 111 - (Fa / F'ey)] Fb} <= 1.0 Job Name: Finish Line Location: Tukwila, WA Order # 796529 KL / R for Single Angle; Bolt Spacing for Composite Action Kx= 1 Ky 1 Lx = 58.5 in. L = 58.5 in. R = 0.2119 in. R = 0.5786 in. (KL / R) = 276.07 (KL / R) = 101.11 (KL / R)max = 276.07 > 200, No Good KL / R for Double Angle; K x = 1 L = 58.5 in. R = 0.3177 in. (KL / R) = 184.14 (KL / R)max = 184.14 <= 200, OK Determine Bolt Spacing for Composite Action; K = 1 L = 58.5 in. R = 0.5786 in. (KL / My = 101.11 (KL / R)Double Angle = E(KL / R) singie Angle 184.136 = [(1) L / 0.2119] + [(1) L / 0.2119] L = 19.51 in. ** Use Bolt Spacing of 19.5" for Composite Action. ** Page: 15 By: LJS Date: 11/20/07 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Sway Brace Calculations Based on 1996 AISI with 1.33 Stress Increase for Seismic Material: AISI 1017 F = 42 ksi F = 56 ksi s = 0.75 in. Allowable Bolt Shear (Table E3.4 -1)t F„ = 24 psi T = 1.33 Ab F,,,, / 2.4 = 652.9 Lbs. db = 0.250 in. Ab = 0.049 in. Bolt ASTM: A307 T = Allowable Tension for One Brace Pair T = Allowable Tension for Two Brace Pairs R = e = 0.266 in. t = 0.097 in. d = 0.281 in. F = 24 psi T = 2 (1.33 Ab F / 2.4) = 1305.7 Lbs. Page: 16 By: LJS Date: 11/20/07 ** Treads are NOT excluded from the shear plane. ** Allowable Bearing on the Brace (Table E3.3 -2); T = 1.33 (2.22 F„ d t / 2.22) T = 2 [1.33 (2.22 F„ d t / 2.22)] = 1806.1 Lbs. = 3612.3 Lbs. Allowable Bearing on Post (Table E3.3 -2); t = 0.150 in. t = 0.150 in. T = 1.33 (2.22 F„ d t / 2.22) T = 1.33 (3.00 F„ d t / 2.22) = 2793.0 Lbs. = 3774.3 Lbs. Allowable Tension on Brace (Eq. E3.2 -2)L A = 0.024 in. A = 0.049 in. r = 1.000 r = 1.000 T 1.33A[1- r +(2.5r d /s]F /2.22 T = 1.33A[1- r +(2.5r d /s]F /2.22 = 678.0 Lbs. = 1356.0 Lbs. Job Name: Finish Line Location: Tukwila, WA Order # 796529 Allowable Edge Distance (Eq. E3.1 -1); T = 1.33teF /2 = 959.5 Lbs. Allowable Tension on Brace Based on Above Parameters; T = 652.9 Lbs. for One Brace Pair T = 1305.7 Lbs. for Two Brace Pairs Side Sway Braces; (Use Elevation C as Worst Case) 1st Panel 34.17 in. 3rd Panel 34.17 in. 97.9 Lbs. = V 33 in. ■ 104.0 Lbs. = 2 x 52 33 in. T = 2(1.33teF u /2) = 1919.0 Lbs. T = 34.17 in. x 97.90 Lbs. / 8.875 in. T = 377.0 Lbs. T = 34.17 in. x 104.00 Lbs. / 8.875 in. T = 400.4 Lbs. Page: 17 By: LJS Date: 11/20/07 Bolt Shear Controls Design Bolt Shear Controls Design Shelf Depth, in. = 12 # of Brace Pairs = 1 Length, in. = 34.704 Tension <= Allowable Tension = 652.9 Lbs. OK Shelf Depth, in. = 12 # of Brace Pairs = 1 Length, in. = 34.704 Tension <= Allowable Tension = 652.9 Lbs. OK Job Name: Finish Line Location: Tukwila, WA Order # 796529 Back Sway Braces; (Elevation A - Double Face Units Control) 1st Panel 53.28 in. 2nd Panel 53.28 in. 61.76 in. 2nd Panel 61.76 in. J 34.625 in. J 34.625 in. J 46.625 in. 46.625 in. J 40.5 in. ■ 246.0 Lbs. = 4 x 61.5 40.5 in. ■ 139.0 Lbs. = 2 V Shelf Width, in. = 36 # of Brace Pairs = 1 Length, in. = 53.815 T = 53.28 in. x 139.00 Lbs. / 34.625 in. T = 213.9 Lbs. Tension <= Allowable Tension = 652.9 Lbs. OK Shelf Width, in. = 36 # of Brace Pairs = 1 Length, in. = 53.815 T = 53.28 in. x 246.00 Lbs. / 34.625 in. T = 378.6 Lbs. Tension <= Allowable Tension = 652.9 Lbs. Back Sway Braces; (Use Elevation C Double Face Units as Worst Case) 1st Panel 40.5 in. ■ 195.8 Lbs. = 2 V ■ 330.8 Lbs. = 4 x 82.7 40.5 in. Shelf Width, in. = 48 #of Brace Pairs= 1 Length, in. = 62.290 T = 61.76 in. x 195.80 Lbs. / 46.625 in. T = 259.4 Lbs. Tension <= Allowable Tension = 652.9 Lbs. OK Shelf Width, in. = 48 # of Brace Pairs = 1 Length, in. = 62.290 T = 61.76 in. x 330.80 Lbs. / 46.625 in. T = 438.2 Lbs. Page: 18 By: LJS Date: 11/20/07 OK Tension <= Allowable Tension = 652.9 Lbs. OK Job Name: Finish Line Location: Tukwila, WA Order # 796529 Front & Rear Flange Ix = Sx = REPUBLIC OPEN FLANGE SHELF ANALYSIS PER THE ANSI MH28.1 SPEC. D/2 D/2 HHI I O I H 11 0.0 149 0.0311 L inA4 In ^3 Moment and Deflection on Side Flange P = Total Load on Side Flange ,z(ch). Mmax = PD /6 = Mallow = SxFy /1.5 = Amax = PDA3 /60EIx = Dallow = D/140 = 1- 3/16" P = WD /4L = 32.5 Lbs. 65.0 in -Lbs 630.00 in -Lbs Mmax/Mallow = 0.103 <= 1.0, Side Flange Moment OK 0.002 in 0.086 in Shelf Depth, D = Shelf Width, L = Shelf Load, W = p Shelf Gage, t = Matl. Yeild Str., Fy = Mod. Of Elasticity, E = Regd. Factor of Safety = Max. Deflection = Ix = Sx = Amax/Aallow = 0.029 <= 1.0, Side Flange Deflection OK Side Flange " I k 3/8 > 0.0128 0.0225 12 36 390 0.035 42,000 29,500,000 1.5 L/140 inA4 In ^3 Page: 19 By: LJS Date: 11/20/07 in. in. Lbs. in. psi psi in. Job Name: Finish Line Location: Tukwila, WA Order # 796529 Moment and Deflection on Front & Rear Edge By Superposition W/2 Mmax = (W /2)L/8 - Pa /2 = 845.0 in -Lbs Mallow = SxFy /1.5 = 870.8 in -Lbs W/2 Mmax/Mallow = 0.970 <= 1.0, Front & Rear Edge Moment OK a =D /6= 2.0 in Amax = [5(w/2)03/384EIx] - [(P /2)a(3L ^2 - 4a ^2) /24EIx] = 0.258 in Hallow = L/140 = 0.257 in Amax/Lallow = 1.002 Amax is within 3% of Aallow, Deflection OK Page: 20 By: LJS Date: 11/20/07 Job Name: Finish Line Location: Tukwila, WA Order # 796529 REPUBLIC SERIES 2000 SHELF ANALYSIS PER THE ANSI MH28.1 SPEC. D/2 D/2 L Front & Rear Edge Ix = Sx = 3/4 k D 0.0349 0.0729 „zcN Mmax = PD /6 = Mallow = SxFy /1.5 = 9/16" 4— in ^4 In ^3 Amax = PD ^3 /60EIx = tallow = D/140 = r 1 moon 'll111111h: >1 spot weld, max. spacing 8" on ctr. Moment and Deflection on Side Flange P = Total Load on Side Flange P = WD /4L = 31.3 Lbs. 62.5 in -Lbs 809.20 in -Lbs 0.002 in 0.086 in Shelf Depth, D = Shelf Width, L = Shelf Load, W = D Shelf Gage, t = Matl. Yeild Str., Fy = Mod. Of Elasticity, E = Reqd. Factor of Safety = Max. Deflection = 1 -1/4" A Y Ix = Sx = Mmax/Mallow = 0.077 <= 1.0, Side Flange Moment OK Lmax/Aallow = 0.026 <= 1.0, Side Flange Deflection OK Side Flange 0.0137 0.0289 12 48 500 0.035 42,000 29, 500, 000 1.5 L/140 in ^4 In ^3 Page 21 By: LJS Date: 11/20/07 in. in. Lbs. in. psi psi in. Job Name: Finish Line Location: Tukwila, WA Order # 796529 Moment and Deflection on Front & Rear Edge By Superposition W/2 Mmax = (W /2)U8 - Pa /2 = Mallow = SxFy /1.5 = Mmax/Mallow = 0.720 Amax = [5(w /2)L^3 /384EIx] Aailow = U140 = Omax/Dallow = 0.994 1468.8 in -Lbs 2041.2 in -Lbs W/2 <= 1.0, Front & Rear Edge Moment OK - [(P /2)a(3L ^2 - 4a ^2) /24EIx] = 0.343 in <= 1.0, Front & Rear Edge Deflection OK P/2 a = D/6 = 2.0 in Page 22 By: LJS Date: 11/20/07 0.341 in Job Name: Finish Line Location: Tukwila, WA Order # 796529 Post Loads (Elevation C Controls); Uplift = Pmin = 218.5 Lbs. V = 97.9 Lbs. for SF Row Bolt Shear = 49.0 Lbs., Assuming 2 Bolts in Line for SF Row Base Plate Tab', Based on 1996 AISI with 1.33 Stress Increase for Seismic Allowable Uplift on Base Plate Tab (Eq. E3.2 -2)L A = 0.021 in. r = 1.000 P 1.33 - r +(2.5r d /s]F /2.22 = 726.0 Lbs. Allowable Uplift on Base Plate Tab (Eq. E3.2 -3)L P = 1.33 F A / 1.67 = 549.1 Lbs. Allowable Bearing on the Tab (Table E3.3 -2); Tai = 1.33 (2.22 F, d t / 2.22) = 1664.5 Lbs. Base Plate & Anchor Bolt Analysis Page: 23 By: LJS Date: 11/20/2007 Fy = 33 ksi F = 58 ksi s = 0.625 in. R = 0.281 in. t = 0.086 in. db = 0.250 in. Bolt Grade A307 Ab = 0.049 in. d = 0.313 in. e = 0.25 in. Job Name: Finish Line Location: Tukwila, WA Order # 796529 Allowable Bearing on Post (Table E3.3 -2); t, = 0.150 in. Tai = 1.33 (2.22 F„ d t / 2.22) = 2793.0 Lbs. Allowable Bolt Shear (Table E3.4 -1)L F,,,, = 24000 psi T = 1.33 Ab F„ / 2.4 = 652.9 Lbs. ** Treads are NOT excluded from the shear plane. ** Base Plate Thickness; L = Length of Bend;ng L■ne — Perforations P = 523.6 Lbs. P = 218.5 Lbs. Allowable Uplift based on Base Plate Thickness; P = 1.33 (.75 L Fy (t1 ^ 2 + t2 ^2)) / (6 X) = 523.6 Lbs. t // ** Base Plate Thickness Controls Design ** L = 1.450 in. t1 = 0.086 in. t2 = 0.179 in. T = 0.266 in. X = 0.602 in. F = 33.0 ksi Page: 24 By: LJS Date: 11/20/2007 OK Job Name: Finish Line Location: Tukwila, WA Order # 796529 Anchor Analysis - From ES Report ESR -1917; Concrete Strength = 3000 psi Anchor Dia. = 0.375 in. hef = 2 in. = Effective Minimum Embedment hmin = 4 in. = Minimum Member Thickness Special Inspection: Yes (Yes or No)? Concrete: Cracked N = 219 Lbs. V / V = 0.0490 51.0, OK Interaction Equation 1.2 >_ N /N +V /V 1.2 >_ N/A s = N/A in. = Minimum Anchor Spacing (N /A for Single Anchor) c = 4.375 in. = Minimum Edge Distance = cac Tension = 218.5 Lbs. Shear = 49.0 Lbs. Allowable Tension = 1102.0 Lbs. Table 9, ESR -1917 Allowable Shear = 999.0 Lbs. Table 10, ESR -1917 Check Interaction Equation per ESR -1917, Section 4.2 If 0.2 V >_ V then the full allowable Toad in tension may be used. 0.2 V = 200 Lbs. V = 49 Lbs. Use full allowable load in tension. N / N a = 0.1983 5.1.0,OK If 0.2 N >_ N then the full allowable load in shear may be used. 0.2 N = 220 Lbs. Use full allowable Toad in shear. Use: Hilti Kwik Bolt TZ Carbon Steel Anchor - 0.375" Dia. w/ 2.00" Min. Embedment Page: 25 By: LJS Date: 11/20/2007 Job Name: Finish Line Location: Tukwila, WA Order # 796529 AREA = 0.1492 Ix = 0.0087 in "4 Sx = 0.0110 inA3 Rx = 0.2415 in. REPUBLIC STORAGE SYSTEMS COMPANY SECTION PROPERTIES OF CLIP SHELVING SINGLE ANGLE POST Thickness = 14 gage ly = 0.0500 i n A 4 Sy = 0.0387 i n A 3 Ry = 0.5786 in. Page: 26 By: LJS Date: 11/20/07 Fy = 42 ksi 0 =0.70 Rz = 0.2119 in. Job Name: Finish Line Location: Tukwila, WA Order # 796529 Area = 0.2985 in "2 Ix = 0.0301 in "4 Sx = 0.0301 in "3 Rx = 0.3177 in. REPUBLIC STORAGE SYSTEMS COMPANY SECTION PROPERTIES OF CLIP SHELVING DOUBLE ANGLE POST 1.7/8" 2 " Thickness = 14 gage ly = 0.0999 in "4 Sy = 0.0774 in "3 Ry = 0.5786 in. Page: 27 By: LJS Date: 11/20/07 Fy = 42 ksi Q = 0.73 Job Name: Finish Line Location: Tukwila, WA Order # 796529 Conterminous 48 States 2006 International Building Code Latitude = 47.46 Longitude = - 122.26 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.428 Ss, Site Class B 1.0 0.489 S1, Site Class B Conterminous 48 States 2006 International Building Code Latitude = 47.46 Longitude = - 122.26 Spectral Response Accelerations SMs and SM1 SMs = FaSs and SM1 = FvS1 Site Class D - Fa = 1.0 ,Fv = 1.511 Period Sa (sec) (g) 0.2 1.428 SMs, Site Class D 1.0 0.739 SM1, Site Class D Conterminous 48 States 2006 International Building Code Latitude = 47.46 Longitude = - 122.26 SDs = 2/3 x SMs and SD1 = 2 /3xSM1 Site Class D - Fa = 1.0 ,Fv = 1.511 Period Sa (sec) (g) 0.2 0.952 SDs, Site Class D 1.0 0.493 SDI, Site Class D Page: 28 By: LJS Date: 11/20/07 ACTIVITY NUMBER: D08 -174 DATE: 04 -08 -08 PROJECT NAME: FINISH LINE SITE ADDRESS: 1017 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bui tJ ng l ivision Public Works Complete Comments: Documents/routing slip,doc 2 -28 -02 PLAN REVIEW /ROUTING SLIT' n PERMIT COORD COPY 0 Atuo Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-10-08 Not Applicable n No further Review Required DATE: DUE DATE: 0508-08 Not Approved (attach comments) DATE: Planning Division Permit Coordinator n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License ALLEGDM0300H Licensee Name ALLEGHENY DESIGN MGMT MC Licensee Type CONSTRUCTION CONTRACTOR UBI 601796079 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 1 154 PARKS INDUSTRIAL DR Address 2 City VANDERGRIFT County OUT OF STATE State PA Zip 15690 Phone 7248457336 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/8/1997 Expiration Date 1/10/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date KURUC, JOHN S PRESIDENT 09/08/1997 DYKES, JACK W VICE PRESIDENT 09/08/1997 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. a Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date FIDELITY & DEPOSIT Until Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ALLEGDM0300H 04/22/2008 NOV 2 9 2007 DENOTES ELEC. ./ (EXISTING) /, t4' -6' SEE ANGLE POST BOLT PATTERN DETAIL ON SHEET *5. 48' 7 '7 �• Tb�I SOS/ ff _ m662r • o O W W I IIR 0 x X 0 0 x 0 0 X 1 RECEIVING 1 (EXISTING) 1 DENOTES ELEVATION OF SHELVING UNIT. X 0 0 x X 0 0 0 x X 6 BAYS a 48' = 288' (24' -0') X 0 0 0 X X 0 0 X X X 0 0 0 X 0 7 BAYS a 48' = 336' (28' -0') M 24' INSTALLER NOTE: CLOUDED DIMENSIONS ARE FOR REFERENCE ONLY. DIMENSIONS WERE SCALED FROM ARCHITECTURAL DRAWINGS AND MAY VARY BASED ON ACTUAL FIELD DIMENSIONS. REVISIONS No changes shall be made too al scope of work without prior approval Building Division NOTE: Revisions will require a new plan submittal and may include additional plan review fees y T + 2 BAYS a 36' + 5 BAYS a 48' = 312' (26' -0') x 0 0 0 X 0 0 0 X X 0 0 X X 0 EPE011itel Gl� _ del D iv 2e36'= zzA T . � ;m4 9119x)iz/ //hi%`IJI.%/1A'// 72' (6' -0') j i' 1' OFF SIDE WALL (TYPICAL) ELEVATI ❑NS 'A', 'C', & 'D' ARE CALLED ❑UTBy ON THE FLOOR PLAN. ALL UNITS WITHOUT DESIGNATI ❑N ARE TO BE ELEVATION 'B'. ell ell 11 / I.////// i a. OFF BACK VALL (TYPICAL) 3 -9' FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authoriz the violation of any adopted code or ordinance. Reel of approved Field Copy and conditions is acknowledg City of Tukwila BUILDING DIV /SIO1N 19 BAYS a 48' = 912' (76' -0') REV. DATE 7 - - 6 BAYS a 48' = 288' (24' -0') 3. UNITS LOADS SHALL NOT ELEVATION A, UNIT LOAD ELEVATION B, UNIT LOAD ELEVATI ❑N C, UNIT LOAD ELEVATION D, UNIT LOAD // .. ///t EXCEED THE FOLLOWING: 7. ONE ANCHOR BOLT REQUIRED PER FOOTPLATE. SEE DETAILS ON SHEETS 5 & 6 FOR ANCHORING DETAILS. EXPIRES 10/25/ OS 1 NOV 2 7 2007 DESCRIPTION INIT. NOTES' 1. DESIGNED IN GENERAL ACCORDANCE WITH THE 2006 INTERNATIONAL BUILDING CODE SS = 1.428g AND S = 0.489g. 2. MATERIAL PROPERTIES' ANGLE POST - ASTM A -36 1011M -2 GRADE 40, FY= 36,000 PSI SHELVES - ASTM A 794 -97 GRADE 1020, FY= 42,000 PSI SWAY BRACES - ASTM A 794 -97 GRADE 1020, FY= 42,000 PSI FOOTPLATES - ASTM A 1008 /A 10008 -02 TYPE B, FY= 33,000 PSI ANCHOR BOLTS - ' X 3i' HILTI KWIK BOLT TZ, (2' MIN. EMBEDMENT) 4. THE CAPACITIES OF THE SHELVES SHALL BE AS FOLLOWS' OPEN FLANGE SHELF, 20GA X 36' X 12' = 390# SERIES 2000 SHELF, 20GA X 48' X 12' = 500# 5. ALL NUTS & BOLTS SHALL BE ASTM A -307 UNLESS OTHERWISE NOTED. 6. SPECIAL INSPECTI ❑N IS REQUIRED FOR ANCHOR BOLTS IN ACCORDANCE WITH SECTION 1704.13 OF THE 2006 IBC AND SECTI ❑N 4.4 OF ESR -1917, 8. REPUBLIC STORAGE SYSTEMS IS NOT RESPONSIBLE FOR THE ADEQUACY OF THE BUILDING FLOOR. DENOTES BACK AND SIDE SWAY BRACE PATTERN. SEE ELEVATIONS ON SHEET *3 L *4. = 500# (5 SHELVES @ 100# - TOP SHELF UNLOADED) = 500# (5 SHELVES @ 100# - TOP SHELF UNLOADED) = 700# (7 SHELVES @ 100# - TOP SHELF UNLOADED) = 200# (2 SHELVES @ 100# - BOTTOM SHELF UNLOADED) Republic Storage Systems LLC 7, 3 / //7 '/ / / ,,, /, 1 RE VIEWED FOR CODE COMPLIANCE APPROVED B I APR 17 20i8 C - Of Tu %la LIGHT DUTY SHOE SHELVING SWAY BRACE LAYOUT FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FOR ALLEGHENY ION RECEIVED CITY OF TUKWILA APR 0 8 2008 PERMIT CENTER GENERAL NOTES! ISSUANCE OF THIS DRAWING FOR APPROVAL DOES NOT CONSTITUTE ACCEPTANCE OF CUSTOMER'S ORDER BY REPUBLIC STORAGE SYSTEMS LLC. THIS DRAWING IS TO BE USED IN PLACING MATERIALS SOLD UNDER THIS CONTR• . CONTRACTOR TO CHECK DIMENSIONS OF JOB SITE AS BLIC STORAGE SYSTEMS LLC ASSUMES NO RESPONSIBILITY FOR GENERAL BUILDING DIMENSIONS. REPUBLIC STORAGE SYSTEMS LLC EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT AND ANY OTHER PROPERTY RIGHTS TO THIS SET OF DRAWINGS AND /OR DOCUMENTS. SAID DRAWINGS AND /OR DOCUMENTS ARE CONFIDENTIAL AND ARE NOT TO BE CHANGED, COPIED OR REPRODUCED IN ANY MANNER WHATSOEVER, NOR ARE THEY TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT THE EXPRESS WRITTEN PERMISSION AND CONSENT OF REPUBLIC STORAGE SYSTEMS LLC. APPROVAL OF THIS DRAWING BY THE ARCHITECT OR ENGINEER SHALL CONSTITUTE A FINAL INTERPRETATION OF ALL OTHER DOCUMENTS RELATING TO THE SUBJECT MATTER OF THE DRAWING. THE ACCEPTANCE OF THIS DRAWING WILL BE CONSTRUED AS AN ACCEPTANCE OF THE FOREGOING AGREEMENT. 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 DATE U/20/2007 PROPOSAL NO. 107 -110 DRAWN BY S. SPAHR SCALE N.T.S. SHEET. 1 OF 6 114_ ORDER Na 796529 CUSTOMER'S N0. 013269 - 00 DRAVING NO. S- 3518 -A RECEIVING (EXISTING) 2 DENOTES WALL TIE BRACKET (SEE WALL TIE DETAIL ON SHEET •6) DENOTES ELEVATION OF SHELVING UNIT. \� / / / /, / / ; /' % /i' EXPIRES 10/25/01 REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2008 City Of Tukwila BUILDING DIVISION RECEIVED CITY i vT Ili k i u. REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING TOP TIE LAYOUT FOR FINISH LINE STORE #896 SDUTHCENTER (TUKWILA, WA 98188) PREPARED FOR' ALLEGHENY DATE 11/20/2007 DRAVN BY S. SPAHR SCALE N.T.S. SHEET, 2 OF 6 PROPOSAL NO. 107 -110 ORDER NO. 796529 CUSTOMER'S NO. DRAVING NO. S- 3518 -B APR 0 8 M a Ord PERMIT CENTER NOV 2 7 2007 W J O 0 1 — POST BACK SVAY BRACE LOCATION — POST 0 N N co N ‘O t'l 0 V (6) / \ \ X 36' FRONT VIEW ELEVATION "A" (STANDING IN AISLE) (1 BAY WIDE) (6) SHELF — SPACING FRONT VIEW ELEVATION "B" (STANDING IN AISLE) - 71 — BACK SVAY BRACE SHELF SPACING — LOCATION 0' I- X ti W 2 N 0 a J Q OL 0 0 — POST — BACK SVAY BRACE LOCATION 0 N N cu p N a 0 CL o W J Z :au sr 2 W = N ro d A J — J siE 0 0 0 a J a N O V 0 N 0 a N R Y 0'. N 0 ND R N 0 (6) (6) — POST — BACK SVAY BRACE LOCATION (6) SHELF SPACING — BACK SWAY BRACE — LOCATION O N (STANDING IN AISLE) O O ° o N 0 0 a 0' W {u ✓ st 2ta DENOTES SWAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "A" ON SHEET *1) (STANDING IN AISLE) (2 BAYS WIDE) BACK SVAY BRACE LOCATION (6) N 0 R J N N a io DENOTES SVAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "B" ON SHEET NI) 0 N O sO 3 co N N O a 0 N O V SHELF SPACING — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "A" (SINGLE ROW) j - SIDE SVAY BRACE LOCATION m III N � O rIRJ n SIDE VIEW ELEVATION "A" (BACK TO BACK) SIDE SVAY BRACE LOCATION 0 v N 0 V SIDE VIEW ELEVATION "B" (SINGLE ROW) DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET I1) — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "B" (BACK TO BACK) DENOTES SWAY BRACE PATTERN (SEE LOCATIONS ON SHEET M1) RE CODE COMPLI NCE APPROVED APR 1 7 200E City Of Tukwila B ILDI . DIVISION RECEIVE D CITY OF TUKW ' 5, (1 BAY WIDE) (2 BAYS WIDE) REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FORT ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET 3 OF 6 PROPOSAL NO. 107 -110 ORDER N0. 796529 CUSTOMER'S NO. DRAVING N0. S- 3518 -C APR Ob /' PERMIT CENTER NOV 2 7 2007 \ / r / \ / \ MI /1111 W J O 0 1 — POST BACK SVAY BRACE LOCATION — POST 0 N N co N ‘O t'l 0 V (6) / \ \ X 36' FRONT VIEW ELEVATION "A" (STANDING IN AISLE) (1 BAY WIDE) (6) SHELF — SPACING FRONT VIEW ELEVATION "B" (STANDING IN AISLE) - 71 — BACK SVAY BRACE SHELF SPACING — LOCATION 0' I- X ti W 2 N 0 a J Q OL 0 0 — POST — BACK SVAY BRACE LOCATION 0 N N cu p N a 0 CL o W J Z :au sr 2 W = N ro d A J — J siE 0 0 0 a J a N O V 0 N 0 a N R Y 0'. N 0 ND R N 0 (6) (6) — POST — BACK SVAY BRACE LOCATION (6) SHELF SPACING — BACK SWAY BRACE — LOCATION O N (STANDING IN AISLE) O O ° o N 0 0 a 0' W {u ✓ st 2ta DENOTES SWAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "A" ON SHEET *1) (STANDING IN AISLE) (2 BAYS WIDE) BACK SVAY BRACE LOCATION (6) N 0 R J N N a io DENOTES SVAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "B" ON SHEET NI) 0 N O sO 3 co N N O a 0 N O V SHELF SPACING — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "A" (SINGLE ROW) j - SIDE SVAY BRACE LOCATION m III N � O rIRJ n SIDE VIEW ELEVATION "A" (BACK TO BACK) SIDE SVAY BRACE LOCATION 0 v N 0 V SIDE VIEW ELEVATION "B" (SINGLE ROW) DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET I1) — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "B" (BACK TO BACK) DENOTES SWAY BRACE PATTERN (SEE LOCATIONS ON SHEET M1) RE CODE COMPLI NCE APPROVED APR 1 7 200E City Of Tukwila B ILDI . DIVISION RECEIVE D CITY OF TUKW ' 5, (1 BAY WIDE) (2 BAYS WIDE) REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FORT ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET 3 OF 6 PROPOSAL NO. 107 -110 ORDER N0. 796529 CUSTOMER'S NO. DRAVING N0. S- 3518 -C APR Ob /' PERMIT CENTER NOV 2 7 2007 \ / / \ / \ \ / \ / \ / \ / \ / \ /\/\ X 0 36\ 36\ W J O 0 1 — POST BACK SVAY BRACE LOCATION — POST 0 N N co N ‘O t'l 0 V (6) / \ \ X 36' FRONT VIEW ELEVATION "A" (STANDING IN AISLE) (1 BAY WIDE) (6) SHELF — SPACING FRONT VIEW ELEVATION "B" (STANDING IN AISLE) - 71 — BACK SVAY BRACE SHELF SPACING — LOCATION 0' I- X ti W 2 N 0 a J Q OL 0 0 — POST — BACK SVAY BRACE LOCATION 0 N N cu p N a 0 CL o W J Z :au sr 2 W = N ro d A J — J siE 0 0 0 a J a N O V 0 N 0 a N R Y 0'. N 0 ND R N 0 (6) (6) — POST — BACK SVAY BRACE LOCATION (6) SHELF SPACING — BACK SWAY BRACE — LOCATION O N (STANDING IN AISLE) O O ° o N 0 0 a 0' W {u ✓ st 2ta DENOTES SWAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "A" ON SHEET *1) (STANDING IN AISLE) (2 BAYS WIDE) BACK SVAY BRACE LOCATION (6) N 0 R J N N a io DENOTES SVAY FRONT VIEW BRACE PATTERN (SEE LOCATIONS ELEVATION "B" ON SHEET NI) 0 N O sO 3 co N N O a 0 N O V SHELF SPACING — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "A" (SINGLE ROW) j - SIDE SVAY BRACE LOCATION m III N � O rIRJ n SIDE VIEW ELEVATION "A" (BACK TO BACK) SIDE SVAY BRACE LOCATION 0 v N 0 V SIDE VIEW ELEVATION "B" (SINGLE ROW) DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET I1) — SIDE SVAY BRACE LOCATION SIDE VIEW ELEVATION "B" (BACK TO BACK) DENOTES SWAY BRACE PATTERN (SEE LOCATIONS ON SHEET M1) RE CODE COMPLI NCE APPROVED APR 1 7 200E City Of Tukwila B ILDI . DIVISION RECEIVE D CITY OF TUKW ' 5, (1 BAY WIDE) (2 BAYS WIDE) REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FORT ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET 3 OF 6 PROPOSAL NO. 107 -110 ORDER N0. 796529 CUSTOMER'S NO. DRAVING N0. S- 3518 -C APR Ob /' PERMIT CENTER NOV 2 7 2007 S W x N 0 a J J Q 14 • 0 O — POST — BACK SWAY BRACE LOCATION • N o o ▪ ,0 -iu (8) BACK SVAY BRACE — LOCATION (8) FRONT VIEW ELEVATION "C" (FIXTURE UNITS) (STANDING IN AISLE) SHELF SPACING — 0 .iU 0■ Y '.0 N DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET *1) 0 P) — SIDE SVAY BRACE LOCATION 0 N N d 0 O .0 a 1 2 X -- DENOTES SWAY BRACE PATTERN (SEE LOCATIONS SIDE VIEW ON SHEET *1) ELEVATION "C" (SINGLE ROW) — POST — BACK SVAY BRACE LOCATION N W 0 A (3) (3) FRONT VIEW ELEVATION "D" (HANGRAIL UNITS) (STANDING IN AISLE) SHELF SPACING — BACK SVAY BRACE — LOCATION N \ DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET 01) N M — SIDE SVAY BRACE LOCATION m N O '.0 m N N O �0 A co N O '.o a l 12'' DENOTES S BRACE PAT (SEE LDCA ON SIDE VIEW SHEET ELEVATION "D" (SINGLE ROW) REVIEWED FOR ODE COMPLIANCE APPROVED APR 1 7 2008 City Of Tukwila BUILDING DIVISION EXPIRES 10/25/09 RECEIVED CITY OF TUKWILA RMIT 0 8 20 RMIT CEN 1 ER NOV 2 7 2001 REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE 14896 SDUTHCENTER (TUKWILA, WA 98188) PREPARED FOR1 ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET, 4 OF 6 PROPOSAL Na 107 - 110 ORDER NO. 796529 CUSTOMER'S NO. DRAWING NO. S- 3518 -D / \ \ N / / \ \ \J / X / . X \ \ / \ \ \ / \ / \ \ \ / / \ \ / / \ \ / X \ X I i / \ / / • \ / \ / \ \ J / X X ,\ ,. / \/ \ / N, / \ 1 0 48\ 8\ S W x N 0 a J J Q 14 • 0 O — POST — BACK SWAY BRACE LOCATION • N o o ▪ ,0 -iu (8) BACK SVAY BRACE — LOCATION (8) FRONT VIEW ELEVATION "C" (FIXTURE UNITS) (STANDING IN AISLE) SHELF SPACING — 0 .iU 0■ Y '.0 N DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET *1) 0 P) — SIDE SVAY BRACE LOCATION 0 N N d 0 O .0 a 1 2 X -- DENOTES SWAY BRACE PATTERN (SEE LOCATIONS SIDE VIEW ON SHEET *1) ELEVATION "C" (SINGLE ROW) — POST — BACK SVAY BRACE LOCATION N W 0 A (3) (3) FRONT VIEW ELEVATION "D" (HANGRAIL UNITS) (STANDING IN AISLE) SHELF SPACING — BACK SVAY BRACE — LOCATION N \ DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET 01) N M — SIDE SVAY BRACE LOCATION m N O '.0 m N N O �0 A co N O '.o a l 12'' DENOTES S BRACE PAT (SEE LDCA ON SIDE VIEW SHEET ELEVATION "D" (SINGLE ROW) REVIEWED FOR ODE COMPLIANCE APPROVED APR 1 7 2008 City Of Tukwila BUILDING DIVISION EXPIRES 10/25/09 RECEIVED CITY OF TUKWILA RMIT 0 8 20 RMIT CEN 1 ER NOV 2 7 2001 REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE 14896 SDUTHCENTER (TUKWILA, WA 98188) PREPARED FOR1 ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET, 4 OF 6 PROPOSAL Na 107 - 110 ORDER NO. 796529 CUSTOMER'S NO. DRAWING NO. S- 3518 -D \ / N \ / / \ \J / \ . X \/ / \ \ / / \ \ / \ \ \ / / \ \ / / \ / X \ X I / • e\ \ J S W x N 0 a J J Q 14 • 0 O — POST — BACK SWAY BRACE LOCATION • N o o ▪ ,0 -iu (8) BACK SVAY BRACE — LOCATION (8) FRONT VIEW ELEVATION "C" (FIXTURE UNITS) (STANDING IN AISLE) SHELF SPACING — 0 .iU 0■ Y '.0 N DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET *1) 0 P) — SIDE SVAY BRACE LOCATION 0 N N d 0 O .0 a 1 2 X -- DENOTES SWAY BRACE PATTERN (SEE LOCATIONS SIDE VIEW ON SHEET *1) ELEVATION "C" (SINGLE ROW) — POST — BACK SVAY BRACE LOCATION N W 0 A (3) (3) FRONT VIEW ELEVATION "D" (HANGRAIL UNITS) (STANDING IN AISLE) SHELF SPACING — BACK SVAY BRACE — LOCATION N \ DENOTES SVAY BRACE PATTERN (SEE LOCATIONS ON SHEET 01) N M — SIDE SVAY BRACE LOCATION m N O '.0 m N N O �0 A co N O '.o a l 12'' DENOTES S BRACE PAT (SEE LDCA ON SIDE VIEW SHEET ELEVATION "D" (SINGLE ROW) REVIEWED FOR ODE COMPLIANCE APPROVED APR 1 7 2008 City Of Tukwila BUILDING DIVISION EXPIRES 10/25/09 RECEIVED CITY OF TUKWILA RMIT 0 8 20 RMIT CEN 1 ER NOV 2 7 2001 REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING ELEVATIONS FOR FINISH LINE STORE 14896 SDUTHCENTER (TUKWILA, WA 98188) PREPARED FOR1 ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET, 4 OF 6 PROPOSAL Na 107 - 110 ORDER NO. 796529 CUSTOMER'S NO. DRAWING NO. S- 3518 -D INSTALLATION NOTE: BOLTS USED FOR SIDE SWAY BRACING SHOULD FACE IN THE SAME DIRECTION. TYPICAL FOR ENTIRE LENGTH OF ROW. THIS EASES THE INSTALLATION OF SHELVES. ANGLE POST i X ' TR HD BOLT & NUT (TYP.) ( #703959 & #703625) SIDE SWAY BRACES SIDE SWAY BRACING SHELF SIDE SWAY BRACING O SIDE SWAY BRACES CONNECTION DETAIL: ANGLE POST SWAY BRACE CONNECTION <BOX SHELF) ANGLE POST BACK SWAY BRACING ANGLE POST BACK SWAY BRACING BACK SWAY BRACING BACK SWAY BRACING 16' 14 GA. X SLOT (TYP) 0fl' HOLES (TYP) u w VARIES • X 12 GA. • T T T L - a ° Q L. _L-} Li_ 1 VAR ES UNIT OVERALL DIMENSION OF RANGE TYPICAL LAYOUT OF ANGLE POST RANGE (S. F. RANGE SHOWN) 5 O ti SHELF CLIP SHELF DEPTH L7 SERIES 2000 SHELF (48' X 12') li SHELF DEPTH PLAIN OPEN FLANGE SHELF (36' X 12') J DIA. FLOOR ANCHOR HOLE ' DIA. FLOOR ANCHOR HOLE d -20 X a' BOLT & NUT i -20 X BOLT & NUT i -20 X BOLT & NUT FOOTPLATE PART #1602261 (2i' X 3' X i' ) i -20 X B' TRUSS HEAD BOLT ( #703959) HEX NUT ( #703625) ONLY (1) ANCHOR REQUIRED PER FOOTPLATE. FOOT PLATE DETAIL FOR ALL UNITS DIA. FLOOR ANCHOR HOLE ' DIA. FLOOR ANCHOR HOLE ANGLE POST BACK & SIDE SWAY BRACE REV. DATE DESCRIPTION INIT. EXPIRES 10/25/ b `p Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHIO 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING DETAILS FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FOR: ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET, 5 OF 6 PROPOSAL NO. 107 -110 ORDER NO. 796529 CUSTOMER'S NO. DRAVING NO. S- 3518 -E 4 -20 X i' TRUSS HEAD BOLT & NUT. BOLT ALONG POST AT 19i' CENTERS MAX. (TYPICAL) TYPICAL ANGLE POST BOLT PATTERN SEE SHEET 1 FOR LOCATIONS (ELEV. 'D' UNITS ONLY) REVIEWED FOR APPROVED COVED APR 1 7 2008 City Of ILDING D1VISTON RECEIVED CITY OF TUKWILA APR 0 8 Z008 PERMIT CENTER NOV 2 7 2007 i' -14 X TEK ( #703487)TEK FROM UNDERSIDE OF SHELF THRU HOLES IN TOP SHELF (TYPICAL) ANGLE POST TOP TIE CONNECTION DETAIL! TOP TIE CHANNEL FROM SHELF TO SHELF (SEE PLAN ON SHEET #2 FOR LOCATIONS) X 1' TOP TIE CHANNEL (FIELD CUT FROM 12' -0' LENGTHS) ( CU H ▪ a o Z Z a . • =s • 1I i = • ° • N Z w a • • °11) a s 'n1 W • , yy ° V • V • ♦ . • ♦ o. • v ' ♦ . • • p ♦ ♦ s • • FACE OF ANGLE POST 'X 3i' HILTI KWIK BOLT TZ ( #701893) • ♦ w 0 Am. o o H W ° ' °. 0 TYPICAL ANGLE POST FOOTPLATE ANCHORAGE (USE ONE ANCHOR PER FOOTPLATE) 14 GA. SECTION VIEW OF TOP TIE CHANNEL TOP SHELF AND THE TOP PORTION OF POST SHOWN FOR REFERANCE ONLY. SECTION OF WALL SHOWN AS REFERANCE ONLY. i' -14 X TEK ( #703487)TEK TO ATTACH BRACKET TO TOP OF SHELF. SHELVING BRACKET #299236 WALL TIE DETAIL ANCHORING FOR UNITS THAT ARE NOT ABLE TO BE TOP TIED TEK BRACKET TO TOP SHELF AND ATTACH AT WALL STUDS WITH APPROPRIATE HARDWARE (SEE PLAN ON SHEET #2 FOR LOCATIONS) INSTALLER NOTE: LOCATE AND ATTACH BRACKET AT WALL STUDS. SELECT SUITABLE HARDWARE BASED ON WALL AND STUD TYPE. (HARDWARE BY OTHERS) RECEIVED CITY OF TUKIMLA APR 0 8 2008 PERMIT CENTER NOV 2 7 2007 REV. DATE DESCRIPTION INIT. Republic Storage Systems LLC 1038 BELDEN AVENUE N.E. CANTON OHID 44705 (330) 438 -5800 LIGHT DUTY SHOE SHELVING DETAILS FOR FINISH LINE STORE #896 SOUTHCENTER (TUKWILA, WA 98188) PREPARED FORT ALLEGHENY DATE 11/20/2007 DRAWN BY S. SPAHR SCALE N.T.S. SHEET. 6 OF 6 PROPOSAL NO. 107 - 110 ORDER NO. 796529 CUSTOMER'S NO. DRAVING NO. S- 3518 -F