Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-204 - WESTFIELD SOUTHCENTER MALL - TUKWILA POLICE SUBSTATION - FRAME AND DOORS
TUKWIi.A POLICE SUBSTATION 539 SOUTH ENTER MALL Parcel No.: 6364200010 Address: 539 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: TUICWILA POLICE SUBSTATION Address: 539 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: CityAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: LITO PANIDA Address: 900 FOURTH AV, SUITE 700 , SEATTLE WA 98164 Phone: 206 - 461 -6000 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Phone: 206 718 -0960 Contractor License No: BNBUII*990K3 DEVELOPMENT PERMIT Permit Number: D08 - 204 Issue Date: 09/25/2008 Permit Expires On: 03/24/2009 Expiration Date: 09/12/2009 DESCRIPTION OF WORK: BRACE FRAME MODIFICATION AND DOORS RELOCATION TO EXISTING TENANT SPACES OF POLICE SUBSTATION SPACE AND BACK OF HOUSE AREA. Value of Construction: $25,000.00 Fees Collected: $833.63 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: doc: IBC -10/06 * *continued on next page ** D08 -204 Printed: 09-25 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: doc: IBC -10/06 City o•Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: 7 Permit Number: D08 - 204 Issue Date: 09/25/2008 Permit Expires On: 03/24/2009 Date: C l 0 S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe ormancepf work. I am authorized to sign and obtain this development permit. Signature: - 2 - ' /1� Date: dL © v This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -204 Printed: 09 -25 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 539 SOUTHCENTER MALL TUKW TUKWILA POLICE SUBSTATION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -204 ISSUED 04/22/2008 09/25/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications. 7: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 8: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 9: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 10: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 11: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 12: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 13: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 14: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. doc: Cond -10/06 D08 -204 Printed: 09 -25 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 17: ** *FIRE DEPARTMENT CONDITIONS * ** 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 19: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 20: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 21: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 22: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 23: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 24: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 25: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: Gates serving the means of egress system shall comply with the requirements of the International Fire Code. Gates used as a component in a means of egress shall conform to the applicable requirements for doors. (IFC 1008.2) doc: Cond -10/06 D08 -204 Printed: 09 -25 -2008 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 31: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 32: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 33: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** D08 -204 Printed: 09 -25 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Z - L--- ------ Signature: Date: ,/05/ Print Name: 1` L pANls 1L ordinances governing or local laws regulating doc: Cond -10/06 D08 -204 Printed: 09 -25 -2008 CITY OF TUKWILL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Illtp://www.ci. tulovila.waus SITE LOCATION & 1' vmtl Tenant Name: W 1�T1 l V'1.0 Property Owners Name: 1u191T1 LUO drAogorness I (N t. • Mailing Address: (((€O1 W1t414'1 kIU1A^21'2 a Fukrt— U$ fr flt'LCS C/4 002$ State Zip Site Address: .CONTACT PERSON — who do we contact when your permit .is'ready.to be issued Name: L( P,or+-1 t r- Mailing Address: an l t11 V- M'i , cut t re 1 - m`rLG tA1t 16 City State Zip Fax Number: - 4 l - b 0 49 E -Mail Address: t PAt^ ∎ tL `Dl - 1Z- G'+f7-q te. - coon GENERAL CONTRACTOR INFORMATION • (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: ( 113 — Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: DAL C11-0•44" ��pp Mailing Address: lb ( 'Flu (74* Pr kilo /'o `>a'T'(t.tt WA- VA,/ i -r City State Zip Contact Person: ( 1 • Vim Day Telephone: --4-4, 1 ^ Goa E -Mail Address: t eft d•- e_ C31.4 4 %a., ('. Fax Number: 7-D - 4' 1 - (#o 41 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Arr3 L' 5 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: Z t2.41 V 2v i11 Q:WpplicationsWorms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. r°— c X/ (For ofce.use only) ' King Co Assessor's Tax No.: - 0010 Suite Number: Floor: City New Tenant: ❑ Yes fi4 .. No Day Telephone: l'OU - 44.1 —CiotO State Zip 4 n-s - rtz (S 12 a City State Zip A Contact Person: gA41' t< • $14 A'i Day Telephone: 206 - - 5Z2 -3 .(21-z E -Mail Address: Fax Number: C— 5t2 —3 if 4 U Page 1 of 6 . . • • Existing . Interior Remodel Addition,to . Existing •• Structure . • . ' ' i, ••.' New Type of Construction per IBC Type.of Occupancy per • IBC . • 1 X. Floor ' "- Floor 'Floors ___ ___ thru 'Basement . Accessory Structure* Attached Garage ' Detached Garage . Attached Carport ':Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO ION — 206- 431 -3670 Valuation of Project (contractor's bid price): $ 7,61 coo Existing Building Valuation: $ Scope of Work (please provide detailed information): rbp,A{'�(:s P/M 4 1.4b0 t il'irt-t p.1/43 si "P1o5r .0 COQ l S 4 - * N-ri.JT cars o Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If `yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line U-2006 - Permit Application. doc Revised: 9 -2006 bh None ❑ Other (specify) Page 2 of 6 • • BUILDING OW R 0 AUTHORIZED GENT: Signature: ,r /� /• Print Name: Z/72) 1 7 , *A1 /vAL Mailing Address: 100 b u ( -119 Av ' • 1117 ?o City Date Application Accepted: Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Day Telephone: Date: 1/ /00- '201s -1/ -G-42 0 tAA , tei r State Date Application Expires: Staff Initials: Zip Page 6 of 6 Receipt No.: R08 -03353 Payee: BNB ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 36724 507.00 RECEIPT Parcel No.: 6364200010 Permit Number: D08 -204 Address: 539 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/22/2008 Applicant: TUKWILA POLICE SUBSTATION Issue Date: Initials: WER Payment Date: 09/25/2008 09:41 AM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000/322.100 502.50 000/386.904 4.50 Total: $507.00 Payment Amount: $507.00 77 95 N/ • T707 f 0T1 -3-CT.)) doc: Receiot -06 Printed: 09 -25 -2008 Receipt No.: R08 -01267 Initials: BLH User ID: ADMIN Payee: WESTFIELD SOUTHCENTER ACCOUNT ITEM LIST: Description rinrc Renpint -118 PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 6012404 326.63 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 6364200010 Permit Number: D08 -204 Address: 539 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/22/2008 Applicant: TUKWILA POLICE SUB - STATION Issue Date: Account Code Current Pmts 000/345.830 326.63 Total: $326.63 • Payment Amount: $326.63 Payment Date: 04/22/2008 11:10 AM Balance: $507.00 1470 04/22 9710 TOTAL 326.63 Printarl n4- 29 -9nnR Project: �J�.w,l' ( :Le Sv ii e o \- A._ (� 1 Typf nspecti Bo.k.jd-- - Al Add: C c Date Called: Special Instructions: / Date Wanted: b . m : Requester: Phone N� n G tOG ~ 4`!/ l 16gv INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ooy-9,621 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r M Inspecto Date: ` El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: k' Ins, 4 /U" (/) F ," ,/A16, 4/ /Wei -- 5 €- 5 1 )6 s, 4 / Date Called: 9lefi/ .5yv ' ' 7fidiri /` 55 -SZ /f( Special Instructions: 7'V / /sole f / " Ar71 / `� � f ^Q a.m. p.m. 5-14.10e. ,- /- fhr / en? /L,./re eP f -- q69 l 7/ 4r - c. v $ t' /i$ -(a1 /1 - I.0.- /l ,fOi ' 6/#9 Zi®V -, -- AIM ,/ > �-,, , Aiel i)07- /5"7 t .3 0 /i- a 1/ - �/sk/ A /I./tv ro, .5 el 41/ AJ /tl (>4,/ /i i J)D7 , 7. Pro'e7 /�Wi 71 9 S76S` fWi k' Ins, 4 /U" Address: ( . 39 Date Called: Special Instructions: Date Wanted. ^Q a.m. p.m. Requester: Phone No: eP f -- q69 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. . � 0.00 REINSPECTION FEE EQUIRE rior to inspection, fee must be paid at 6300 Southcenter B d., Suit 00. Call to schedule reinspection. (Receipt No.: 'Date: ?-20 `/ Project: ,,,, l oII S Osk 420 of Inspection: h , Address: Suite #: 531 5 Z Ail y__ Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: A /A_ Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ' f ... INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWI1.A.FIRE DEPARTMENT D O ?J LOti PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa: 98188 206 -575 -4407 n Corrections required prior to approval. • COMMENTS: t Ye 114, Ok Inspector: j-/ ' Date : _ t7$ Hrs:: Ti $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Departmerit. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 September 30, 2008 KA Project No. 066 -06316 Permit No. D08 -204 CITY OF TUKWILA ATTN: BUILDING DEPARTMENT 6300 SOUTHCENTER BLVD TUKWILA, WA 98188 RE: Final Letter Regarding: Westfield Mall Expansion — Security Office 633 Southcenter Blvd. Seattle, WA To Whom It May Concern: In accordance with your request and authorization, we have performed special testing and inspection services for the above referenced project. The special inspections for this project were: • Proprietary Anchors (epoxy Reinforcing • Welding Steel) • Reinforced Concrete To the best of our knowledge, all work which has been tested and/or inspected has been found to be in general accordance with the approved plans and specifications, engineering revisions, and Chapter 17 of the 2006 International Building Code. If you have any questions or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC. gGr3.a Kathryn E. Gordon Project Manager Puyallup Division Cc: GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION Westfield Corp. ANF & Assoc. BNBuilders. azan & ASSOCIATES, INC. With Offices Serving The Western United States 922 — Valley Avenue NW Suite 101 • Puyallup, WA 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 RECEIVED OCT - 2 2008 COMMUNI I Y DEVELOPMENT ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers STRUCTURAL ENGINEERING CALCULATIONS 800 Fifth Avenue, Suite 2500 Seattle, Washington 98104 Tel: 206.340.2255 Fax: 206.340.2266 www.abkj.com r FELE COPY Permit No. cm!sticrs. Westfield Shoppingtown Security S ffice Remodel Braced Frame Modifications Tukwila, WA - REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 2 2008 30 May 2008 ABKJ Project Number (08062.00) Volume (1 of 1) Submitted to: BN Builders, Inc. 2601 Fourth Avenue, Suite 350 Seattle, WA 98121 Tel: 206.382.3443 Fax: 206.382.3440 RECEIVED CITY OF TUKVVILA JUN 0 3 2008 PERMIT CENTER CORRECTION LTR# 1 ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers STRUCTURAL ENGINEERING CALCULATIONS 800 Fifth Avenue. Suite 2500 Seattle. Washington 98104 Tel: 206.340.2255 I Fax: 206.340.2266 www.abkj.com Index to Structural Calculations: 30 May 2008 ABKJ Project Number (08062.00) Pages: Existing Frame Evaluation & Bracing Member Design B1 — B3 Structural Plans and Details D1 — D7 6-z ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers 800 Fifth Avenue. Suite 2500 Seattle,Washington 98104 PROJECT 5 0 V fl. CA/Tee ,S Gu /2/ ► 7 SUBJECT /• ' A - 1C- 0/0 mopitie $ / U; GS w 6s 5o s ,25 0.- (0,38)Ew = o'ZC. [W3 (4J0 PRA-4 AL. /V C, d j�lOL /M= S i hrtiCt k�P !' r o, /'9 24. 8 ' 2 0' SS. (20)1v 2,37 0,3$ / o < once Tel: 206.340.2255 1 JOB # ,D a -Gi. MtM8i R S / ?.Gs To Re 7ivv,f/Of Rcuts Es /oG 1,23 = fr V-r • HS J 5 x 5 x 3 �/ rr A So* 60t2AG A1€mee1€ S T/A00 /YI 040E1- L 5 ,RA riE F,e4m AL6 /v 6 4/2,/o tut /3 Jbfu ce o, 8S( Z9; a) /2 = /0 C ,7 y 17 /65 0 viE 1-/S.5 6 x 6 , 3/, Aro �C Be i3'R' ME' 5 TA oo m oOEc_ P /LE 11 L ) 9 ,' 4me Fax: 206.340.2266 I www.abkj.com 3c• &IAA ' O H BY ` artNA/STON SHEET# S l / B 3 = /oC DATE 4-, ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers 800 Fifth Avenue, Suite 2500 Seattle.Washington 98104 Tel: 206.340.2255 PROJECT 50Ujfl Cevvre , 5 EG U/Ciry D`ftc' JOB# SUBJECT PA2471/te /y/ O01 / Cl+l) Oc BY 0. 5, „1 Hp/ S n N 1 e f /311/,t' ,?1A7 i m rn Tet''J' l.(% 811 e x / sric.f Af E'?7 6Oe TENsi o, 2 o n ' lye "vii'► 1 T _ � f (430(31 0°4)00) = 2 4 57x, T - �.d (21(4) 5,67 0, 592 GS u1JE 1' 7 ;a5Jer & Fvt t; i °E NS TR,4 6p (311 ( c066) /,33 (a, 'J r 43052 C 6 A4 P/ 3 E 7-0 J C le1 /,/S 3 ,ry v i ree Fax: 206.340.2266 le o P P A wee ►ve✓2f ' /w C7?6P .' DATE • 3 o MAR ( o 8 SHEET# 2 � 3 R t -iweeie f ; # ( �AGlio w > C.Rrr.( w z .11' . 11' 0 " `i f 4kSk W'i L r = !7') 4 e•fr Ct41/00 5 o a a W LI u G x G (.1 Z 'J www.abkj.com ae 11_5 5-)c 3/ 6 A s o o 8 113 5 6 k 6 x * a4. A- So 0 ,/ t1Cr A,2E £A Ti SPA c ni y Po.E' St - -t'e ? /W 1I /ti✓o CA'PA - c � 77 s- et ABKJ1 ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers 800 Fifth Avenue, Suite 2500 Seattle,Washington 98104 PROJECT 5 0 U Tif Ci ,1, ree .SEG we TV OPA Ce. JOB # SUBJECT / :"--- /Q/ 411 / - in 027/ F/ 0477 0 ea f BY 12- V SHEET# 03703 7??2 /Ylln B14R C6- NIen9ee2 J7-'4 17f Go'✓i'C'n cr/ 45,32/19; 'VC-T F - f6 o00( 3, - 2a) /So 98D ?-Ery 6 o/= WeL' 4.e 24 1 _ 1 fl Eco J Vex' f / OW. y L!°/'/2 " nil, 1.1/y H oA/ 2 6,n/i A L Al Roof 8A `/.,02 /2 (2X1,9/) 8,2 = Z3,/ fa ZT V - 0 CA-1, rr V✓ C 0_ J /►?r-) Z v0 r (Z) (/ ,9 / ) r,Z = 23,/ r ' J, 2 DE 7Y! //vim 4 f/ J JJ 7 P L .57 Ze A 4uriE r o -d 0 3 Z. 4 t)J E 4 T . /i 1f X Tel: 206.340.2255 16°°°(,9$) _ /33080 (vet 1,c,Er RE u/Rc"r. /e36gfl 5 0 A �- Z �'^ _rat 9 N 1 Fax: 206.340.2266 1 /8'3 _ /I z " 0 0 °o,6(36 ) W /Ty 3/4" `ic t er wEIS www.abkj.com DATE 30 M4 1 1Q O el s -s 5 ooTi-IGCn/ fne SSGun C6 rE) VU /6x3 I (E) w 1;1-x ZZ `r ( Rot, rC3R r ✓ To BE ,otrio P F°/Vie 77A L ROOF FRA A4/// 4 P L. ,4ti 4 fr. 9/30/ zoos n / /o7 � $'Q urH ce/N in?2 SE G U2,T7 d ff,C • Ti G LANE „ ‘ 5 ` PEA/ M 0 L) if/ C T/ Dom/ Tr-"/.1% a' ' , o p 13,e4-6/.4 To oe OE.no'o 7YP / C4 - z- -- ( TT"/ S i oni R o0 C3i24c /N o ro BE D6Y10JO 8 � 2/OLi�E 11 /5 Q�eA�E Moo/ /CA7�b� S -1 ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers 800 Fifth Avenue, Suite 2500 Seattle,Washington 98104 NOTE • PROJECT SDU TA/ Cti✓T .T000R dPMc JOB # SUBJECT F: 714 6 in b O/ P/G 417 o rJ - DE 'MIL S BY PA O N 3 /g 3/g Tel: 206.340.2255 SI /& FP-W9' STN'F' rcf�, E Lc= vAriara /f/4,-/ ,4 t(- ME S A-1 7 f W o2 K Pouf rr. Z X41 Pt_ a y ci) d/v r s A 2E Qu//ec'3, 3. BRA ce s , ,/ / v 1 JC 7 , 4/V war; 7746 v 7 77 cAL- P4An6 of 7h( V•/ PGf1Yk VW 63, TYP. ,E ,QA-C E TO (E) IAJ E A A CO/\A1 Fax: 206.340.2266 I www.abkj.com DATE 3 b /14A,e /p O3 /p SHEET# (C} ROOD - APE cK.,,, 4 - (E) w B 11 '1'. 3 V8 sT /rte= E t. / /t GJJEr . BRft - re. "FOR ._ �c,eus�n 0e _IL 07 F(1/e /rJQ776# or G) v.r JE r peArC ABKJI ANDERSEN • BJORNSTAD • KANE • JACOBS Consulting Civil and Structural Engineers 800 Fifth Avenue, Suite 2500 Seatde,Washington 98104 .. w - !/2 5 /r - ��� or cat. () Cori& .C7)12 oP PANCL 5K 2 ELS VAT/ 0/v Tel: 206.340.2255 PROJECT 50 LITS c/ J6 U R/ rr SUBJECT FRAM/e FRAM/e 47 OO/ G/ c.477 oi' • J .DE4er /G 5 BY PS ,7blIN417D/ SHEET# o' � / o / JOB # (E) coo (,./E cAP Fax: 206.340.2266 www.abkj.com DATE 0 0 n4,47Q !O 8 et-EVA .07 /= ace . .. - . /, . /52777 s.-4 o u J'""T le. '/i G r.fJ T /L $AJE • 711U 7'K 1 / PL A7v 3 �g „ -f • GE vei4- � 4 . 4Rouf (4) — 3 /1 7 O'A Atc ?02 R oz S Oni3e, 8`• /r/Ti (0 Cv w/ . / 10 o x Y No 7 E 1. AL 4 /4 Lc M eined2 r A me WO >aK Po fr /T, 2 Err4PG -o ' * G? 0•-! 8 a c,.5 /45 REGiu €c4v• ENO a u,l Jerr fre./ 4/•l W/ 01 rile 0fl C 0L!/Jl7 g . ; t7 ern oc,, JIa 7 Jf / 0 , /@ N0 ri u JJE 7” / ■6 R t// 1 ' T ` , , 8 �' /rG6 To (� 11/ G 0 /„_///v6 - '' SP STRUCTURAL INSPECTIONS: t 0 Q�p .1. IN ACCORD WITH 203'IBC, SECTION 17 4, AS_NOIED BELOW. TESTING AND INSPECTION SHALL BE BY AN INDEPENDENT . TESTING/INSPECTION FIRM UNDER THE SUPERVISION OF A UCENSED ENGINEER EMPLOYED BY THAT FIRM. THIS ENGINEER SHALL BE DEEMED THE DESIGNATED ENGINEER OF RECORD FOR SPECIAL INSPECTIONS PERFORMED BY HIS FIRM OR HIS CONSULTANTS. INSPECTORS SHALL BE ICBO CERTIFIED AND APPROVED BY THE BUILDING OFnaAL 2. THE DESIGNATED ENGINEER OF RECORD FOR SPECIAL INSPECTIONS SHALL BE RESPONSIBLE FOR DEFINING THE ACTIVITIES OF THE INSPECTORS. FOR CERTIFYING THE QUAUFICATIONS OF THE INSPECTORS WITH THE BUILDING OFFICIAL, AND TO ATTEND THE PRECONSTRUCTION MEETING TO DEFINE THEIR SCOPE OF SERVICES AND THE TESTING OR TEST PROCEDURES THAT ARE REQUIRED AS OUTLINED IN THE INTERNATIONAL BUILDING CODE 3. SPECIAL INSPECTION IS TO BE PROVIDED IN ADDITION TO THE INSPECTIONS CONDUCTED BY 114E LOCAL DEPARTMENT OF BUILDING SAFETY AND SHALL NOT BE CONSTRUED TO RELIEVE THE OWNER OR HIS AUTHORIZED AGENT FROM REQUESTING THE PERIODIC AND CALLED INSPECTIONS REQUIRED BY SECTION 109 OF THE INTERNATIONAL BUILDING CODE. 4. WELDING: PER SEC110N 1704.3 WITH EXCEPTIONS. PROVIDE INSPECTION OF ALL SHOP WELDING AT CONTRACTOR'S EXPENSE F WELDING IS NOT DONE IN AN APPROVED FABRICATOR'S SHOP. 5. HIGH STRENGTH BOLTNNG: PER SECTION 1704.3.3. 6. EXPANSION BOLT, SCREW ANCHOR AND ADHESIVE ANCHOR INSTALLATION TO VERIFY INSTALLATION IN ACCORD WITH ICBO REPORTS NOTED PREVIOUSLY OR APPROVED EQUAL 7. THE INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS 8. THE INSPECTOR SHALL FURNISH DAILY INSPECTION REPORTS ON THE WORT( TO THE BUILDING OFFICIAL AND TO THE ENGINEER ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. AND, IF UNCORRECTED. TO THE ENGINEER AND THE BUILDING OFFICIAL. 9 • THE TESTING/INSPECTION FIRM'S ENGINEER SHALL COMPLETE, SIGN AND SEAL A FINAL REPORT CERTIFYING THAT TO THE BEST OF HIS KNOWLEDGE. THE WORK IS IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. $44) 09 -08 -2008 LITO PANIDA 901 FOURTH AV, SUITE 700 SEATTLE WA 98164 RE: Permit Application No. D08 -204 539 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 04/22/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 10/19/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 10/19/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Pe 't Technician xc: Permit File No. D08 -204 City of Tu Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 29 May, 2008 To: Mr. Allen Johannessen, Plan Examiner City of Tukwila Department of Community Development Building Department 6300 Southcenter Blvd., Suite 100 Tukwila, Washington 98188 -2544 RE: Permit Application No. D08 -204 Dear Mr. Johannessen: I am responding to your letter dated 5 -6 -2008 regarding the correction letter #1. 1. Provide plan drawings that are on a minimum size 11 x 1 7 inch sheets. Plan documents and text shall be enlarged to a size that can be more readable. Comply 2. General notes refer to outdated building and energy codes. Revise all plan notes and code reference to reference the current 2006 building and energy codes. Comply see revised sheet G0.3 3. Provide a table or reference the type of special inspections required for the structural work. Comply. 4. Provide a reflective ceiling plan to identify changes or additions to lighting and mechanical diffusers. No changes required to existing HVAC & lighting system. HVAC & lighting are not affected by the new changes. Please call me if you have any questions or require addition information about the project. Sincerely, DL Group to T. Panida, Associate AIA • • Seattle Chicago Colorado Springs Denver Des Moines Honolulu Kansas City Minneapolis Omaha Orlando Philadelphia Phoenix Portland Sacramento DLR Group Architecture Engineering Planning Interior 901 Fifth Avenue Suite 700 Seattle, WA 98164 tel 206/461 -6000 fax 206/461 -6049 www.dlrgroup.com May 6, 2008 Lito Panida 901 Fourth Avenue, Suite 700 Seattle, WA 98164 RE: CORRECTION LETTER #1 Development Application Number D08 -204 Tukwila Police Substation - 539Southcenter Mall Dear Mr. Panida, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 - 133 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ff� Brenda Holt Permit Coordinator encl File No. D08 -204 • Cizy of Tukwila Department of Community Development Jack Pace, Director P:\Pemtit Cen ter \Correction Letters\2008\D08 -204 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: April 30, 2008 Project Name: Tukwila Police Substation Permit #: D08 -204 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide plan drawings that are on a minimum size 11 x 17 inch sheets. Plan documents and text shall be enlarged to a size that can be more readable. 2. General notes refer to outdated building and energy codes. Revise all plan notes and code reference to reference the current 2006 building and energy codes. 3. Provide a table or reference the type of special inspections required for the structural work. 4. Provide a reflective ceiling plan to identify changes or additions to lighting and mechanical diffusers. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 -204 DATE: 06 -03 -08 PROJECT NAME: TUKWILA POLICE SUBSTATION SITE ADDRESS: 539 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: (to Bu I #: Dken Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 HERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Fire Prevention n Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: DUE DATE: 06-05-08 Not Applicable ❑ No further Review Required DATE: DUE DATE: 07-03-08 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division n Permit Coordinator n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -204 DATE: 4 -22 -08 PROJECT NAME: TUKWILA POLICE SUBSTATION SITE ADDRESS: 539 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: Bid g Di ision P c Wo ►'N.A. • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Structural Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 Incomplete ❑ S�� +_ Plan ril5g`Division Permit Coordinator DUE DATE: 4-24-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R UTING: Please Route 311 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: DUE DATE: 5-22-08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: �lJ �Q b Departments issued corrections: Bldg I Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: ❑ Response to Incomplete Letter # ® Response to Correction Letter # • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Received at the City of Tukwila Permit Center by:'i kr Entered in Permits Plus on 0t(/U t V 0 \applications \forms- applications on 1ine\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Sheet Number(s): ALA- SIit E . 4VtSteeD "Cloud" or highlight all areas of revision including date of revision Dos-20+ Steven M Mullet, Mayor Steve Lancaster, Director e19 ti RECEIVED /JUN 0 3 2008 PERMIT CENTEFI Project Name: ( lA- pOIACG Su13Slikno .L Project Address: 15/ SaM ¶14 0A0 1b12.. PriftlitiCr AA Contact Person: LI TO T. ?A -N094 Phone Number: We - 44.1 • C•OOO Summary of Revision: 4 Ja•R -c 1 9)1 % aP X 11 Da foe, #r u'bmao PAuluotr coo €. Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS & SURETY CO 10335590008/30/2001 09/07/200809/07 Until Cancelled $12,000.0009/06 /2001 2 TRAVELERS CAS & SURETY CO 103355900 01/01/2001 08/30/2001 $6,000.00 02/05/2001 1 UNITED PACIFIC INS CO 6877797 09/07/2000 Until Cancelled 04/27/2001 $6,000.00 Name Role Effective Date Expiration Date BASTIAN, BRAD PRESIDENT 05/23/2001 Amount NIELSEN, JEFF VICE PRESIDENT 05/23/2001 TBKZ91442966028 Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/200809/07 /2009 $1,000,000.0009 /05/2008 WAUSAU Untitled Page Business Owner Information Bond Information Insurance Information • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company B N BUILDERS INC 2067180960 2601 4TH AVE STE 350 SEATTLE WA 98121 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602056687 ACTIVE BNBUII*990K3 CONSTRUCTION CONTRACTOR 5/23/2001 9/12/2009 BASTINB000OJ PURODSI984JN GENERAL UNUSED Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= BNBUII* 990K3 09/25/2008 3 SOUTHCENTER MALL INTERIOR RENOVATIO INDEX OF DRAWINGS GENERAL G0.0 COVER SHEET AND SHEET INDEX G0.1 OVERALL EXISTING ARCHITECTURAL SITE PLAN G0.2 PARTIAL MALL PLAN ARCHITECTURAL C-1D•3 c E t3L I1.1��tt A1.0 PARTAIL DOSING POUCE SUB - STATION FLOOR PLAN A2.0 0008 TYPE & SCHEDULE STRUCTURAL 5-1 THRU S-10 BRACED FRAME MODIFICATION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE Revisions will require a new plan submittal and may include additional plan review fees. Westfield 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 PERMIT SET 4 -15 -2008 SUMMARY OF WORK VICINITY MAP NEW DOOR LOCATION & FRAME MODIRCAIONS TO EXISTING POUCE- SUBSTA101 SEPARATE PERMIT REQUIRED FOR: M� RE� an1caI Er Electrical i g u ae mbing PIPktil City of Tukwila BUILDING DIVISION PROJECT SUMMARY PROJECT TEAM OWNER WESTFIELD CORPORATION, INC. 11601 WILDHIRE BOULEVARD, 12114 FLOOR LOS ANGELES. CALIFORNIA 90025 T: 206.802.6076 F: 206.246.2856 C: MIKK SEPP E: MSEPPOWESTFIELD.COM ARCHITECTURAL DLR GROUP. INC. 900 FOURTH AVENUE, SUITE 700 SEATTLE, WA 98164 T: 206.461.6000 F: 208.461.6049 C: LITO T. PANIDA E: LPANIDAODLRGROUP.COM STRUCTURAL ABKJ 2601 FOURTH AVENUE. SUITE 350 SEATTLE. WA 98121 T: 208.382.3443 F: 208.382.3440 C: ARUN K. BHAGAT. P.E RECEIVED CITY OF TUKWILA JUN 0 3 2008 1705 PERMIT CENTER NbiteSSATIC COD opROV 1UN 12 2008 a pproved Reid oond�t B yy, % Date °i /ZS /DS FILE COPY Permit No.�b$'20�' City of Tukwila BUILDING DIVISION CORRECTION LT R# 2 Plar review approval Is subject to errors and ornon 3. N Approval of cons documents does not aufhori the violation of any adopted code or ordinance. Receipt o of ons is aclatowledged: r� °o z 0 2 • • .. :1' • •µ • s p a• r r a w M J • \J n . , f, 1 rt G O 0 O CU b 6 0 ' .\: • ` ;• 1t ' • :( Mg 4 . . .Z OM ' 7 1 ,:=, 'rim w - 7C171 0 M NOT TO SCALE DLR Group Oxon. ...R.M....* N . IIEZEINED Architecture Engineering Planning Interiors • /1 G0.1 • 73- 0712&03 01- 152008 ..._. '4 • i :,? t °Aril. F.-,. r fi. F 3 1 i I� � � � 1 1 I t L, �y . l • t ... it .L i . i . . j , . .. �. OVERALL EXIST. ARCHITECTURAL SITE PLAN Southcenter Mall Interior Renovation 111 .' ..r1 *F53Sti,' • • .- 1 ' + 11 . : rrt ignO rn iND g ® O '4 • 5188 REGISTE D ARCHITE'T SC I T. KRUSE F W'SHINGTON 0 0 . -- t ir1 ;i Ex ='si ANCI ,R 174,630 S.F. 7'1 �iiG .A : -4 • • • POLICE SUB - STATION SPACES NORTH NOT TO SCALE RECEIVED CITY of TUKWILA JUN 0 3 2008 PERMIT CENTER Ea PARTIAL MALL PLAN csi 0 GENERAL NOTES GENERAL NOTES 1. GENERAL NOTES APPLY TO ALL SHEETS: 2 . ALL DIMENSIONS ARE ACTUAL AND ARE TO FACE OF STUDS, FACE OF CONCRETE WALLS, FACE OF CMU WALLS, FACE OF FRAMES. OR CENTERUNE OF COLUMNS, UNLESS NOTED OTHERWISE. 3 . FLOOR SPOT ELEVATIONS ARE SHOWN THROUGH 4. ALL WALLS SHALL EXTEND TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE UNLESS NOTED OTHERWISE. 5 . PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NONBEARING WALLS FOR 1 -INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING MATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. 6 . THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL WOOD BLOCKING IN METAL STUD PARTITIONS FOR THE PROPER ANCHORAGE OF ALL WALL ATTACHED ITEMS. 7 . ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE - RESISTIVE RATING AND SMOKE STOPPAGE. 8 . THE OWNER SHALL BE RESPONSIBLE FOR PROVIDING THE CONTRACTOR WITH ROUGH -IN INFORMATION NECESSARY TO ACCOMMODATE THE INSTALLATION OF OWNER FURNISHED AND INSTALLED OR CONTRACTOR INSTALLED ITEMS. 9 . THE CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS. 10. GENERAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THE MECHANICAL CONTRACTOR. 11. GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL WORK WITH THE ELECTRICAL CONTRACTOR. ON PLANS. 12. DIMENSIONS FOR DOOR AND WINDOW OPENINGS ARE SHOWN NOMINAL. ALLOW FOR 1/4 -INCH (SHIM AND SEALANT OF EXTERIOR FRAMES. 13. SCRIBE GYPSUM BOARD OF WALL AND PARTITIONS TO IRREGULARITIES OF DECK ABOVE. SEAL TIGHTLY AROUND ANY PARTITIONS. 14. ARCHITECTURAL FINISHED FLOOR ELEVATION O' -0 ". In?. E. FL 15. NOT USED 16. CONTRACTOR SHALL VISIT THE SITE. FAMIUARIZE HIM/HER SELF WITH EXISTING CONDITIONS AND REVIEW AND UNDERSTAND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL VERIFY AU. DIMENSIONS, ELEVATIONS AND CONDITIONS PRIOR TO BEGINNING ANY WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CORRECTIONS AND REPAIRS REQUIRED DUE TO HIS/HER FAILURE TO DO SO. 17. SOLELY AS A CONVENIENCE TO THE OWNER AND CONTRACTOR, THE ARCHITECT MAY INCLUDE DOCUMENTS PREPARED BY CERTAIN CONSULTANTS (OR INCORPORATE THE RECOMMENDATIONS OF SAND CONSULTANTS INTO DOCUMENTS PREPARED BY THE ARCHITECT WITHIN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT). IT IS EXPRESSLY UNDERSTOOD, THAT BY SUCH ISSUANCE, THE ARCHITECT ASSUMES NO UABIUTY FOR THE SERVICES OF SAID CONSULTANTS 200 4 18. ALL WORK AND MATERIALS SHALL CONFORM TO THE LATEST ADOPTED 4863 INTERNATIONAL BUILDING CODE AS AMENDED, ALL ORDINANCES AND REGULATIONS OF THE CITY OR COUNTY WITH JURISDICTION AND SPECIAL REQUIREMENTS INDICATED IN THE BUILDING SUMMARY OR THESE GENERAL NOTES. 19. WHEN REQUIRED EXIT DOORS SWING OUT OVER AN EXTERIOR LANDING. THE LANDING SHALL BE MORE THAN 1/2" BELOW FINISHED FLOOR. 20. CONTRACTOR EGULATIONS AND RESTRICTIONS A REQU REQUIRED FOR WORKER RESPONSIBILITY AND PEDESTRIAN PROTECTIONS COMPLY SAFETY CTIONS DURING THE OF R R CONSTRUCTION OF NE PROJECT. PROVIDE PROTECTIONS AS REQUIRED TO PREVENT ANY DAMAGE TO EXISTING CONSTRUCTION WITHIN AND ADJACENT TO JOB SIZE WHERE DAMAGE OCCURS. NE CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED AREA AND /OR MATERIAL AS REQUIRED TO THE OWNER'S APPROVAL AT NO ADDITIONAL COST. THIS REQUIREMENT SHALL APPLY CONTINIOUSLY AND NOT BE UMITED TO NORMAL WORK HOURS. 21. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, UTIUTIES, OTHER SERVICES AND RELATED TASKS NECESSARY FOR PROPER EXECUTION OF THE CONSTRUCTION REQUIRED BY CONTRACT DOCUMENTS. 22. ANY REVISION OR ADDITIONAL WORK REQUIRED BY FIELD CONDITIONS OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. 23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS, LICENSES, INSPECTIONS AND TESTING INDICATED ON THE PLANS AND SPECIFICATIONS OR REQUIRED BY ANY GOVERNMENT AGENCY. 24. UNLESS OTHERWISE INDICATED ON THESE DRAWINGS AS BEING "N.I.C. ", ALL ITEMS, MATERIALS, ETC. AND INTSALLATION OF THE SAME ARE PART OF THE CONTRACT DEFINED BY THESE DRAWINGS. 25. THE BUILDING AND FACIUTY IS TO BE ACCESSIBLE TO AND FUNCTIONAL FOR THE PHYSICALLY DISABLED PUBLIC IN ACCORDANCE - WITH THE AMERICANS DISABILITIES ACT (ADA) AND ALL OTHER STATE/FEDERAL GOVERNING AGENCIES. 26. THIS PROJECT MEETS 'THE ADA REQUIREMENT 27. PROVIDE FIRE RETARDANT WOOD FIREBLOCKING WITH A MAXIMUM SPACING OF 10' -0" HORIZONTAL AND VERTICAL IN ALL FRAMED WALLS. 28. ALL LEGAL EXITS SHOWN ON THE PLAN SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ANY SPECIAL LOCKING DEVICE SHALL BE OF APPROVED TYPE. FLUSH BOLTS ARE NOT ALLOWED. MAXIMUM EFFORT TO OPERATE EXIT DOORS SHALL NOT EXCEED 8.5 LBS FOR EXTERIOR DOORS. 5 LBS FOR INTERIOR DOORS AND 15 LBS FOR FIRE RATED DOORS. 29. FIRE SAFETY DURING CONSTRUCTION, ALTERATION OR DEMOUTION SHALL COMPLY WITH ARTICLE 87 OF THE UNIFORM NFPA BUILDING CODE. PROJECT DATA & CODE SUMMARY SOUTHCENTER MALL RENOVATION CODE SUMMARY APPUCABLE CODES 2006 INTERNATIONAL BUILDING CODE (IBC), WAC 51 -50 AND COMPLIANCE WITH CITY OF TUKWILA ZONING. 2006 INTERNATIONAL FIRE CODE (IFC), INCLUDE APPENDIX B & C 2005 NATIONAL ELECTRICAL CODE (NEC) 2006 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51 -52 2006 UNIFORM PLUMBING CODE (UPC), WAC 51 -56 & 51 -57 INCL APPENDIX CHAPTERS H & L ASHINGTON STATE ENERGY CODE (WSEC), WAC 51 - 52 NG: OCCUPANCY GROUP EXISTING M: MERCANTILE - COVERED MALL BUILDING NOTE: 1. NO INCREASE IN BUILDING GROSS LEASE AREA OR BUILDING AREA. 2. EXISTING PARKING COUNT TO REMAIN NO INCREASE. CONSTRUCTION TYPE EXISTING MALL 2N, (FULLY SPRINKLERED) EXSITNG BUILDING AREA NORDSTROM 171,275 S.F. (3 levels) MACY'S 250,407 S.F. (4 levels) SEARS 174,630 S.F. (3 levels) JCPENNEY 276,468 S.F. (3 levels) VACANT AN HOR 65 273 S F. (2 levelsl TOTAL DEPARTMENT GLA 938,053 S.F. SMALL SHOPS TOTAL SHOPS GLA TOTALEXISTWG SITE GLA 1,215,908 S.F. OCCUPANT LOAD: (EXISTING) MEANS OF EGRESS: EXISTING) DISTANCE TO EXITS: - TRAVEL DISTANCE SHALL BE NOT EXCEEDED 200 FEET MAXIMUM FROM WITHIN A TENANT SPACE TO THE MALL - TRAVEL DISTANCE FROM ANY POINT WITHIN THE MALL TO A MALL EXIT OR TO A 66" MINIMUM WIDTH EXIT PASSAGEWAY SHALL NOT EXCEED 200 FEET. FIRE PROTECTION - EXISTING COVERED MALL BUILDING IS SPRINKLED THROUGHOUT. ANY NEW RETAIL SPACE SHALL BE FULLY SPRINKLERED AND CONNECTED TO THE EXISTING STANDPIPE PER 402.8.1 AND 905.3.3. PLAN LEGEND All WALL TYPES 1) WALL TYPE "1" KWILA URBAN CENTER 277.855 S.F. 277,855 S.F. INDICATE AREA OF WORK TO BE DONE FOR EXISTING POUCE SUB - STATION. NEW 3 5/8 " METAL STUD 016" O.C. NEW 2" BAT INSULATION NEW 5/8" GWB ON BOTH SIDES PAINT. EXISITNG BUILDING S.F. TO REMAIN. RECEIVED CITY OF TUKWILA JUN 0 3 2008 PERMIT CENTER • "- • .:: • • • • •';; i• EXISTING STORAGE ROOM < > • EXISTING BACK OF HOUSE < > EXISTING STORAGE ROOM < > NEW 3-5/8 MTL STUD WALL W/ 5/8" GWB ON BOTH SIDES OVER r BATT. INSUL PAINT WALL TO MATCH. ALIGN WALL WITH EXISTING CEILING ID ABOVE. J EXISTING BACK OF HOUSE < > NEW OFFICE < > EXISTING STORAGE ROOM < > EXISTING STORAGE ROOM <> • .._ , -i" EXISTING RESTROOM < 110 > EXISTING STORAGE < 112 > EXISTING OFFICE <107> EXISTING FIRE EXTINGUISHER REMOVE EXISTING DOOR AND PROMO WD TRIM AROUND OPEN I : I •,67 CLOSET RM1 NEW 3-5/8" MIL MID WALL W/ 5/6* GWB ON BOTH SIDES OVER r BATT. INSU P NT TO EXISTING DOOR T 1.• EXISTING CORRIDOR < > EXISTING BREAK ROOM <TOT> EXISTING GENERAL OFFICE <106> • ' EXISTING " . EXISTING EXISTING ELEC. RESTROOM RESTROOM.,- PANEL • < 101 EXISTING • • OFFICE.-SPACE-.. - - '••'• < 102 > EXISTING DISPATCH < 105 > EXISTING SECURITY OFFICE SPACE <103> EXISTING OFFICE SPACE <104> EXIS11NG WAITING AREA <105A> —4EVEVAF SAE APPROVED JUN 12 2000 City Of Tukwila ILDIN DWSiQL PARTIAL EXIST. POLICE SUB-STATION FLOOR PLAN RECEIVED CITY OF 'TUKWILA JUN 0 3 2008 PERMIT CENTER N OR TH Southcenter Mall Interior Renovation , • g MITI .. t" : 1111.111.11111.111M MIAVOI;14,3.112,00 m.......■,. iria:1 "'MERIN Ir MI ‘, IR 14 . .. . .. ,... 'f ''`. -- 1 . IL ... , i - II 1111111161:12Eas"M III/REUI -",-. • , --AM • BM • "- • .:: • • • • •';; i• EXISTING STORAGE ROOM < > • EXISTING BACK OF HOUSE < > EXISTING STORAGE ROOM < > NEW 3-5/8 MTL STUD WALL W/ 5/8" GWB ON BOTH SIDES OVER r BATT. INSUL PAINT WALL TO MATCH. ALIGN WALL WITH EXISTING CEILING ID ABOVE. J EXISTING BACK OF HOUSE < > NEW OFFICE < > EXISTING STORAGE ROOM < > EXISTING STORAGE ROOM <> • .._ , -i" EXISTING RESTROOM < 110 > EXISTING STORAGE < 112 > EXISTING OFFICE <107> EXISTING FIRE EXTINGUISHER REMOVE EXISTING DOOR AND PROMO WD TRIM AROUND OPEN I : I •,67 CLOSET RM1 NEW 3-5/8" MIL MID WALL W/ 5/6* GWB ON BOTH SIDES OVER r BATT. INSU P NT TO EXISTING DOOR T 1.• EXISTING CORRIDOR < > EXISTING BREAK ROOM <TOT> EXISTING GENERAL OFFICE <106> • ' EXISTING " . EXISTING EXISTING ELEC. RESTROOM RESTROOM.,- PANEL • < 101 EXISTING • • OFFICE.-SPACE-.. - - '••'• < 102 > EXISTING DISPATCH < 105 > EXISTING SECURITY OFFICE SPACE <103> EXISTING OFFICE SPACE <104> EXIS11NG WAITING AREA <105A> —4EVEVAF SAE APPROVED JUN 12 2000 City Of Tukwila ILDIN DWSiQL PARTIAL EXIST. POLICE SUB-STATION FLOOR PLAN RECEIVED CITY OF 'TUKWILA JUN 0 3 2008 PERMIT CENTER N OR TH Southcenter Mall Interior Renovation DOOR MARK 101 105 106 J-0' K-0' RAID Sao rbaD r w 2 Pa ir 6 . — DOOR SCHEDULE DOOR SZE THKNS TYPE MAT FINISH s -0• x 1 -0• x 1 -0' 6' -0 X 1 -0' 1� ir 1j rw wvD sao a1 r` PANT DR 2 SCUD 110 SOLID %VD SOLID YA DOOR SCHEDULE PAINT PANT PLANT FRAME TYPE FINISH RATNG M1L MIL MIL PAINT PAINT PAINT HARDWARE NOTES GENERAL HARDWARE NOTES• 1. PROVIDE ALL LOCKSETS LESS CYLINDER, TYPICAL 1 HARDWARE NOTES: 2. PROVIDE US 26D FINISH: SATIN CHROME 3. PROVIDE CUTOUTS FOR SPECIFIED HARDWARE. 4. PROVIDE WALL STOPS IF WALL IS ADJACENT AT 90 DEGREES FROM DOOR + / -. PROVIDE FLOOR STOPS AT OTHER LOCATIONS. 5. G.C. PROVIDE RG -27 FOR EXIT DEVICE AND ELECTRIFIED BY EXIT DEVICE. 6. YALE 1210 CYLINDER SHALL BE DMDED EQUALLY BETWEEN GB THROUGH GH SECTIONS. 7. OR APPROVED EQUAL 1 I 1HR HARDWARE GROUPS HG1 HARDWARE 1 1/2 PR HINGES HAGER FBB179, US26D 1 EACH DOOR STOP HAGER HAG -230W, US26D 1 EACH LOCK SET AU5407 OR PB5407 NO /CR US26D 1 EACH CLOSER YALE 4400 BFSB, US26D 1 EACH SMOKE SEAL PEMKO S88D LOCKSET OFFICE: YALE 540LN AU x 1210 26D LOCKSET STORAGE: YALE 540LN AU x 1210 26D HDYYR GROUP HG1 HG1 HG1 CLOSER LCN CLOSER LCN CLOSER LOUVER —REVIEWED FOR— O CE CODE COMPLIANCE AO 12 200 COI Of Tukwila B ILDIN DIVISI DETPJLS JAMB SILL REMARKS 1 HR RATED MAIN 20 MIN. SMOKE SEAL 1 HR RATED WITH 20 MIN. SMOKE SEAL RE CEIVED CITY OF TUKWILA JUN 0 3 2008 PERMIT CENTER o a a $