HomeMy WebLinkAboutPermit D08-237 - TELE DATA SYSTEMS - TENANT IMPROVEMENT'1'r:LE DATA SYSTEMS
12 INTERURBAN AV S
D08-237
Parcel No.: 0004800003
Address: 12600 INTERURBAN AV S TUKW
Suite No:
Owner:
Name: CIO EPROPERTYTAX INC
Address: DEPT #207 , PO BOX 4900 85261
Phone:
City* Tukwila
Tenant:
Name: TELE DATA SYSTEMS INC
Address: 12600 INTERURBAN AV S , TUKWILA WA
Contact Person:
Name: DAVID KEHLE
Address: 1916 BONAIR DR SW , SEATTLE WA 98116
Phone: 206 - 433 -8997
Contractor:
Name: CP CONSTRUCTION SERVICES LLC
Address: 811 87TH AVE SE , EVERETT WA 98205
Phone: 425 -345 -0830
Contractor License No: CPCONCS933BH
doc: IBC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
DEVELOPMENT PERMIT
* *continued on next page **
•
Permit Number: D08 -237
Issue Date: 06/03/2008
Permit Expires On: 11/30/2008
Expiration Date: 01/08/2009
DESCRIPTION OF WORK:
TENANT IMPROVEMENT - REMOVE EXISTING CEILING TILES AND GRID AND INSTALL NEW SUSPENDED ACOUSTIC
CEILING
Value of Construction: $6,000.00 Fees Collected: $269.33
Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006
Type of Construction: VB Occupancy per IBC: 0008
D08 -237 Printed: 06-03 -2008
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
governing this work will be complied
Signature:
Print Name:
doc: IBC -10/06
City oftukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
N
N
N
I hereby certify that I have read and $xan ned this permit and know the same to be true and correct. All provisions of law and ordinances
The granting of this permit does not presume to
construction or the performance
, whether specified herein or not.
authority to violate or cancel the provisions of any other state or local laws regulating
rized to sign and obtain this development permit.
Date: 06 - 0J - 0 E
Permit Number: D08 -237
Issue Date: 06/03/2008
Permit Expires On: 11/30/2008
Number: 0 Size (Inches): 0
Start Time: End Time:
Volumes: Cut 0 c.y. Fill 0 c.y.
Start Time: End Time:
Private: Public:
Profit: N Non - Profit: N
Private: Public:
Date: CU 1 C ""
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
D08 -237 Printed: 06-03 -2008
Parcel No.: 0004800003
Address:
Suite No:
Tenant:
doc: Cond -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
12600 INTERURBAN AV S TURIN'
TELE DATA SYSTEMS INC
1: ** *BUILDING DEPARTMENT CONDITIONS * **
7: ** *FIRE DEPARTMENT CONDITIONS * **
PERMIT CONDITIONS
•
Permit Number:
Status:
Applied Date:
Issue Date:
D08 -237
ISSUED
04/29/2008
06/03/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design
requirements of ASCE 7.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
8: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
9: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during
demolition and construction.
10: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at
one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is
calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A,
20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
12: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated
at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
D08 -237 Printed: 06-03 -2008
inches (102 mm). (IFC 906.7 and IFC 906.9)
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
16: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table
1015.1 of the International Fire Code and International Building Code.
17: Minimum widths of corridors shall be maintained in accordance with Chapter 10 of the International Building Code and
the International Fire Code.
18: In Group B and M occupancies, the minimum clear aisle width shall be determined by the occupant load served, but shall
not be less than 36 inches. (IFC 1013.4.1)
19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
21: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means
of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of
egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be
diminished along the path of egress travel (IFC 1003.6)
22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the
nearest visible exit sign. (IFC 1011.1)
24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the
aisles shall be unobstructed. (IFC 1013.4)
26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
doc: Cond -10/06
D08 -237 Printed: 06-03 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
27: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a
conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an
approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3)
28: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
29: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating
and/or adding sprinlder heads. (IFC 901.4)
30: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and
approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler
systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk
Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to
the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050)
31: All sprinlder system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila
Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80)
32: U.L. central station supervision is required. (City Ordinance #2050)
33: All valves controlling the water supply for automatic sprinlder systems and waterflow switches on all sprinlder systems
shall be electrically supervised. (City Ordinance #2050)
34: All exterior components of sprinkler systems should be painted RED. This includes: Post indicator valves (PIV), outside
stem and yoke (OSY), wall indicator valves (WIV), and Fire Department connection (FDC). (City Ordinance #2050)
35: Fire department connections ( FDC's) shall be oriented in the direction of fire apparatus access, have a 4 foot clear
space in front and to the sides of the connection, be appropriately signed and protected from potential vehicular
damage.
36: The fire department connection (FDC) shall have a downward angle bend between 22.5 and 45 degrees, with a 5 -inch Storz
fitting(s) and Knox FDC locking Storz cap. (NFPA 13- 6.8.3) (City Ordinance #2050)
37: The height of fire department connections (FDC's) shall be 36 to 48 inches above grade.
38: Fire department connections ( FDC's) shall be located within 50 feet of a fire hydrant.
39: For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant is within
150 feet of a building and so that no point of a building (around its perimeter) is greater than 300 feet from a
hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. (City Ordinance #2052)
40: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may
require relocating and/or adding automatic fire detectors.
41: .An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of
Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Pukwila Ordinance #2051.
42: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
doc: Cond -10/06
D08 -237 Printed: 06 -03 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
43: Local U.L. central station supervision is required. (City Ordinance #2051)
•
44: The installation of wiring and equipment shall be in accordance with N.F.P.A. 70, Article 760, Fire Protective
Signaling Systems. (NFPA 72- 1.3.3)
45: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which
reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #2051)
46: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72
(4.4.1.4.2.1))
47: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control unit(s)
location to provide notification of fire at that location. (NFPA 72)
48: The reset code for the fire alarm panel or keypad shall be 1- 2- 3 -4 -5. The reset code shall not be changed without
approval of the Fire Marshal. The reset code should be permanently posted at the keypad. (City Ordinance #2051)
49: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate
key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire
Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance
#2051)
50: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox
keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information.
51: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
52: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70)
53: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall
provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC
110.26(A) thru F(2))
54: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22)
55: Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL
ROOM" or similar approved wording. (IFC 605.3.1)
56: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to
location on property, fire resistive requirements based on type of construction, draft stop partitions and roof
coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored
or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1)
57: Fire doors, fire windows and fire dampers shall have a label or other identification showing the fire protection
rating. Such label shall be approved and shall be permanently affixed. (IBC 715.3 Table 715.3, 715.4, 716.3.1 Table
716.3.1)
58: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials
shall meet the requirements of International Building Code 803.
59: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth
in Table No. 803.5 of the International Building Code.
doc: Cond -10/06
D08 -237 Printed: 06-03 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
60: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of
fire and smoke, the assembly shall be maintained. (IBC 712.4.2)
61: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite,
room or apartment number in a conspicuous place near the main entry door. (IFC 505.1)
62: Every building shall be accessible to Fire Department apparatus by way of access roadways with all- weather driving
surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided width
an approved turn- around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #2047)
63: There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such
stairways be used for any purpose. (IBC 315.2.4)
64: All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of
construction. (IFC 503.1, 508.1)
65: Aboveground gas meters, regulators and piping exposed to vehicular damage due to proximity to alleys, driveways or
parking areas shall be protected in an approved manner. (IFC Ch. 312, sec. 312.1 thru 312.3)
66: Combustible material shall not be stored in boiler rooms, mechanical rooms or electrical equipment rooms. (IF'C
315.2.3)
67: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
68: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
69: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * **
70: Prior to final permit sign -off applicant shall submit copies of passing annual backflow test reports fot fire
prevention (DDCVA) Detector Double Check Valve Assembly and irrigation (DCVA) Double Check Valve Assembly.
doc: Cond - 10/06
* *continued on next page **
D08 -237 Printed: 06 -03 -2008
1
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
1
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the performance of work.
doc: Cond -10/06
Date: 0 6- 67 - D y
D08 -237 Printed: 06-03 -2008
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: I2 O V�- Zue 141.LLVE
�le
Tenant Name: i //6� � - ���� < <� --
Propert Owners Name: !D Mar Walt
Mailing Address: 6210 ( t Vi ( t - PI)
Name: [ht o Kelitt l
Mailing Address: Alto VatIg 1 2 ∎Y
e
E -Mail Address: a Iik e d et' e a rri i• Gem
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
Company Name: RY49 Autitzt
Mailing Address:A lee ► Ibt 2
Contact Person: CVU7 /EIS
E -Mail Address: a KEW e o w,
QMppliamionsWa msnpplicatiod on LneO -2006 - Permit Appliadon.doe
Revised: 9.2006
eh
King Co Assessor's Tax No.:-4' ° _ 3
Suite Number: isc Floor: 1
New Tenant: Yes El ..No
City
wb. qt17
SIAM;
CONTACT PERSON - who do we contact when your permit is ready to be issued
Day Telephone: 2a 'B3
1t \Vb AR O
/
City State Zip
Fax Number: g—S4 3
ZIP
City State
Day Telephone:
Fax Number.
Expiration Date:
ARCHITECT OF' RECORD - All plans must be wet stamped by Architect of Record
V6 kW,
City
State ZIP
Day Telephone: 4tr 4 `8 61,14 Fax Number: /0 — a 361
ENGINEER OF RECORD -All plans must be wet stamped by Engineer of Record
Company Name: I'lyt
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number.
State
ZIP
Page 1 of 6
BUILDING PERMIT INFORMACN - 206 -431 -3670
•
Valuation of Project (contractor's bid price): $ re/ err, Existing Building Valuation: $ 1.4 t11t Ua4
Scope of Work (please provide detailed information): QA U/ a ,11U { (nu ..LC lilt Q( ';ou-
Pod 49inalvo Jour -*u &HARI
Will there be new rack storage? ❑.....Yes 131. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ .......Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach lint ofmateriaLs and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safe Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: 1Applicatinna\Famu`Applications Oh U603-2006 - Pcmut Applimtioo.doc
Revised: 9
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
l' Floor
I 44
L
taco
a
3'e,
p ja
2 Floor
,
3 Floor
Floors thru
Basement
Accessory Structure'
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
19
BUILDING PERMIT INFORMACN - 206 -431 -3670
•
Valuation of Project (contractor's bid price): $ re/ err, Existing Building Valuation: $ 1.4 t11t Ua4
Scope of Work (please provide detailed information): QA U/ a ,11U { (nu ..LC lilt Q( ';ou-
Pod 49inalvo Jour -*u &HARI
Will there be new rack storage? ❑.....Yes 131. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ .......Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No
If "yes', attach lint ofmateriaLs and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safe Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: 1Applicatinna\Famu`Applications Oh U603-2006 - Pcmut Applimtioo.doc
Revised: 9
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Valve of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 ORIZED AGENT:
Signature:
Print Name:VT ` ff//��.,,''
1I + Ii
Mailing Address: 1 itLO &11662.
Date Application Expires:
IU- Z0 -015
Date Application Accepted:
Q:twppiicatians \Forms - Applications On U \3 -2(106 • Pe mit Appiicatian.doc
Revised: 9.2f)06
bh
Date: I 7'4 1°
Day Telephone: lifer 4-33 --B t 4 g-
al/Me VD eibilli
City state ZiP
Staffinitial�
Page 6 of 6
Parcel No.: 0004800003 Permit Number: D08 -237
Address: 12600 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 04/29/2008
Applicant: TELE DATA SYSTEMS INC Issue Date:
Receipt No.: R08 -01404
Initials: BLH
User ID: ADMIN
Payee: DAVID KEHLE ARCHITECTS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 18273 104.33
ACCOUNT ITEM LIST:
Description
PLAN CHECK - NONRES
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Account Code Current Pmts
000/345.830 104.33
Total: $104.33
Payment Amount: $104.33
Payment Date: 04/29/2008 02:22 PM
Balance: $165.00
07
1785 04/29 9711 TOTAL 2933.21
(Inn! Rarpint -OR Printari• 04- 2A -20n8
Project:
7T GE L 4
Type of Inspection:
,cr.v4 /
Address:
/2 (,o0 , 7 t// / /1 /h
Date Called:
Special Instructions:
/ /
Date Wante
6 ,-6-- e5
Z
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
00- -z_37
INSPECTI • NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1¢-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
1
Inspector:
Date: '- %
6tA---41.
A
❑ $60.00 RINSPECTION FEE REQUIRED.7`rlor to inspection, fee must be
paid at Southcenter Blvd., Suite 100. Call to schedule reinspection.
t
Receipt N o :
'Date:
•
Project:
Type0 Inspection:
4,-
/2
Wi mt
Called:
60 LS v7
v
Special Instructions:
7 '
I
Date Wanted :
®
Vi m:
Requester:
Pho No:
COMMENTS:
• I ' J
h4j-P ei wit 7 1
r ^ S t
G 4 1( 6A le( ( f
60 LS v7
rii‘<t
I
Inspect r:
Date: r r } - JK
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
X
PERMIT NO.
MI
(206)431 -3670
Ei r proved per applicable codes. Corrections required prior to approval.
❑ $60.00 REINSPECTION FEE REQt71RED. Prior to inspection, fee must be
paid at 6300 Southcenter$lvd., Suite 100. Call to schedule reinspection.
(Receipt No.:
(Date:
COMMENTS:
ffh'?riq-!
i, [b v4P
`i . -
'
i J AJ � r-+C�„ I' 6 J
A 1,J
k r d i Par ! u c1 4 -4 a j Ar
/ a u
,
t ('. z-t. J e.J , -- -
Requester:
0
N s` (- 1 ter — thril
./1c.,K--
(--, r rc-A-1 e (:) ) " -s
,A ((
J' (-44. / « Ain/v.6f
Af A ' ^- kr4
t
fi . 1
Projcg—� ��7A'
Type nspe0on: �� � , � /11(
Address: 1--
/a2. `,n/iPrwh
Date C Iled:
�---
Special Instructions:
Date:Wanted:
"•,, --r,- f�
p.m.
Requester:
Phone 4->- 34'5- 41/46
❑ Approved per applicable codes.
,Dam 237
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION i ce"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Corrections required prior to approval.., (
Inspecto :
Date:
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
BUILDING - NONRES
STATE BUILDING SURCHARGE
Payee: CP CONSTRUCTION SERVICES, LLC
ACCOUNT ITEM LIST:
Description
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1116 165.00
000/322.100
000/386.904
RECEIPT
Parcel No.: 0004800003 Permit Number: D08 -237
Address: 12600 INTERURBAN AV S TUKW Status: APPROVED
Suite No: Applied Date: 04/29/2008
Applicant: TELE DATA SYSTEMS INC Issue Date:
Receipt No.: R08 -01902 Payment Amount: $165.00
Initials: JEM Payment Date: 06/03/2008 09:51 AM
User ID: 1165 Balance: $0.00
Account Code Current Pmts
160.50
4.50
Total: $165.00
3180 06/03 9711 TOTAL 185.00
rinr.: Raceint -06 Printarl: (1R- n3- 2flf1R
Project: Ter / apt") S .3
Type of Inspection: � -
y)4 ..44,..-s r'`eyi 1 rote e. /14a. I
Address: / Z6va 7,4er,.' /t #N • -I.
Suite #: J10
Contact Person:
Special Instructions:
Phone No.:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & gct:
Monitor:
Pre -Fe
Permits: _
Occupancy Type: _
:�:.��ait"° - -. :??�Fd✓.':t';�z'b't�A�s� - °^��'.+:r'`L''
l
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTME
444 Andover Park East. Tukwila. Wa. 98188
_Oat 237
PERMIT NUMBERS
206- 575 -4407
1
Approved per applicable codes.
pi Corrections required prior to approval.
COMMENTS:
. aw
Inspector: j, ,5'J
\ 1. Date: 04 /
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. You will r an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Word /Inspection Record Form: 1/13/06'
T.F.D. Form F.P. 113 '
tr
Opaque Concrete /Masonry Wall Requirements
Wall Maximum U- factor is 0.15 (R5.7 continuous ins)
CMU block walls with insulated cores comply
If project qualifies for Concrete/Masonry Option, list walls
with HC z 9.0 Btu /ft °F below (other walls must meet
Opaque Wall requirements). Use descriptions and values
from Table 10 -9 in the Code.
Wall Description
(including insulation R -value & position)
U- factor
y,.,.,
,,, o i
v
v/ � i - E 4
0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces
Semi-Heated Path as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall
Q no insulation requirement is reduced (2008 change). Only available in prescriptive path.
For Budding epartment Use
,6 ' `�%" i t�`�"yf
Pin
l e RP/re -..
/ L0 016:: '�V
D
— 'vl1
I � , MA,
. r EE 'elI
Y ��' ®i
Y j
9 vt" Ilpp //
/
�lA vv
Applicant Phone: , 3 J 4 .
uwnt
N eu �--,,�/�Y ,- 8 ���I
9
I �,.
I
t ER � IN(lrZ' 4la
_`xS
roes
Project Info
Project Address
Glazing Area Calculation
Note: Below grade walls may be included in the
Gross Exterior Wall Area if they are insulated to
the level required for opaque walls.
Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1.
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area times 100 equals % Glazing
Date b
y,.,.,
,,, o i
v
v/ � i - E 4
0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces
Semi-Heated Path as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall
Q no insulation requirement is reduced (2008 change). Only available in prescriptive path.
For Budding epartment Use
,6 ' `�%" i t�`�"yf
Pin
Applicant Name:
Applicant Address
mama m
*H- t
pry "°. "1!!
�lA vv
Applicant Phone: , 3 J 4 .
uwnt
Space Heat Type
Q Electric resistance 0 All other (see over for definitions)
Glazing Area Calculation
Note: Below grade walls may be included in the
Gross Exterior Wall Area if they are insulated to
the level required for opaque walls.
Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1.
(rough opening) Gross Exterior
(vertical & overhd) divided by Wall Area times 100 equals % Glazing
_ X 00
'
Concrete/Masonry Option
0 yes Check here if using this option and if project meets all requirements for the Concrete/Masonry
Option. See Decision Flowchart (over) for qualifications. Enter requirements for each qualifying
0 no assembly below.
0 yes Check here if using semi - heated path and if project meets all requirements for semi - heated spaces
Semi-Heated Path as defined in section 1310. Requires other fuel heating and qualifying thermostat. Only wall
Q no insulation requirement is reduced (2008 change). Only available in prescriptive path.
2006 Washington State Nonresidential Energy Code Compliance Forms
Project Description
2006 Washington State Nonresidential Energy Code Compliance Form
Envelope Summary
Climate Zone 1
ENV -SUM
Compliance Option
Prescriptive ❑ Component Perforrttance
(See Decision Flowchart (over) for qualifications)
Envelope Requirements (enter values as applicable)
Minimum Insulation R- values
Roofs Over Attic
All Other Roofs
Opaque Walls'
Below Grade Walls
Floors Over Unconditioned Space
Slabs -on -Grade
Radiant Floors
Opaque Doors
Vertical Glazing
Overhead Glazing
Maximum U- factors
Maximum SHGC (or SC)
Vertical/Overhead Glazing
New Building ❑ Addition (Alteration .
AEC
CITY of TU
APR 2 9 2
1. Assemblies with metal framing must comply with overall U- factors ' ERMIT CE
Notes: Nb Gi '1b Maltz Wo
❑ Change of U
Seattle EnvSttl .°
Systems Analysis
Revised July 2007
1 1 VFVOG..a araes....�.b
Location
(floor /room no.)
. . _'---a—
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
��
',fl C DR
1
1� �_
., �
,�t 1 1�rgPI li
ONCE a
r L JLi�.s
}�
E ms(
1
2 a ?r
na1
i�►S
Obi Ot ni altr411-
_-AAi
1
1 111m
Pits
---
wo-:
Total Proposed Watts may not exceed Total Allowed Watts for Interior
Total Proposed Watts
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Farms
Revised July 2007
Project Info Project Address
Applicant Address:
Applicant Phone:
v0 1.lbin ii oq
�' � ft No.
Project Description
Compliance Option
❑ New Building El Addition Alteration Plans Inducted
Refer to WSEC Section 1513 for control!; and commissioning.require rbtg_
0 Prescriptive 0 Lighting Power AlloLvance 0 Systems - Analysis . - , ^
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
is Less than 60% of the fixtures new, installed wattage not increased. & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floorlroom no.)
Occupancy Description
From Table 15-1 (over) - document all exceptions on form LTG -LPA
Allowed
Watts per ft
Area in ft
Total Allowed Watts
Allowed x Area
Notes:
1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank.
RECEIVED
CITY OF TIUKW IA
R 2 9 2000
PERMIT CE$TEk
boB -z31
david
kehle
May 15 2008
City of Tukwila
6200 Southcenter Blvd.
Tukwila, Washington 98188
Attn: Ms. Joanna Spencer
Re: Tele Data Systems Inc.
D08 -237
Dear Joanna,
Per your letter to RREEF dated 5/12/08, regarding the above tenant improvement permit, the
owner is having the fire line backflow test report and the landscape DCVA both tested this
weekend with reports to you next week.
Please release the tenant improvement permit.
Sincerely,
David Kehle
DK/mt
Cc: Mr. Greg Coleman
0225 /tukwilacommercepark/citylet5 -15-08
1916 Bonair Drive S.W.
Seattle, WA 98116
•
RFCF VFD
MAY 1 6 2008
PUBLIC WORKS
b08�
(206) 433 -8997
fax (206) 246 -8369
email: dkehle @dkehlearch.com
May 12, 2008
RREEF Corporation
12760 Gateway Dr, Suite 200
Tukwila, WA 98168
•
city of Tukwila
Department of Public Works James E Morrow, P.E., Director
RE: Tele Data Systems Inc. Tenant Improvement
12600 Interurban Ave South, Tukwila WA
Permit No. D08 -237
To Whom It May Concern:
In accordance with Washington State Department of Health guidelines for Group A Public Water
Systems, Public Works has implemented a cross - connection control program to protect the public water
system from contamination via cross - connection. The program requires elimination or control of any
cross - connection between the distribution system and a consumer's water system by the installation of an
approved backflow device. The City has determined that the building at the above address has
deficiencies on fire, and landscape irrigation lines.
a) Fire Line
The subject building is past due on it's annual backflow test report. Please have the DDCVA tested
by a certified tester and submit a copy of passing backflow test report to Public Works ASAP.
b) Landscape Irrigation Line
The Double Check Valve Assembly (DCVA) is past due on it's annual backflow test report. Please
have the backflow tested and submit a copy of backflow test report to Public Works ASAP.
The Public Works Director will withhold permit D08 -237 Tenant Improvement final sign -off until the
Permit Center receives passing backflow test reports.
Please call Mike Cusick, Public Works Senior Water and Sewer Engineer, at (206) 431 -2441, or Jim
Morrow, Public Works Director, at (206) 433 -7161, if you have any questions.
Sincerely,
1oanna Spencer
Development Engineer
JS:jjs
cc:
David Kehle
(P: Laurie Admin/Joanna/Letter Rreef Corporation 051208)
PERMANENT FILE COPY
Jim Haggerton, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 433 -0179 • Fax: 206 - 431 -3665
Hi Joanna,
Joanna Spencer - Re: 12600 Interurban Av
From: Bryan Still
To: Joanna Spencer
Date: 05/01/2008 3:26 pm
Subject: Re: 12600 Interurban Ave S
Are they current on their backflows ?
Thanks, Joanna
D08 -237
They are not current on Fire or irrigation annual testing.
AMR o.k.
RPPA on domestic o.k.
Thanks Bryan
»> Joanna Spencer 04/30/2008 4 :26 pm »>
Bryan:
D08 -237
•
PERMANENT FILE COPY
DOS 23'"7
Page 1
ACTIVITY NUMBER: D08 -237 DATE: 04 -29 -08
PROJECT NAME: TELE DATA SYSTEMS INC
SITE ADDRESS: 12600 INTERURBAN AV S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #_
Revision # After Permit Issued
DEPARTMENTS
BDic inc ision
PLAN �� ��W /ROUTI SLIP
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ❑V Incomplete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUESITHURS ROUTING:
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved n
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2-28-02
Ora A-IP al 4215
Fire Prevention JEL
Structural
Approved with Conditions
n
DUE DATE: 05 -01 -08
Not Applicable ❑
DATE:
DUE DATE: 05 -29 -08
Not Approved (attach comments)
DATE:
5 �1
Planning Division
Permit Coordinator U
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
CPCONCS933BH
Licensee Name
CP CONSTRUCTION SERVICES LLC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
602428728
Ind. Ins. Account Id
#1
Business Type
LIMITED LIABILITY COMPANY
Address 1
811 87TH AVE SE
Address 2
City
EVERETT
County
SNOHOMISH
State
WA
Zip
98205
Phone
4253450830
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/8/2007
Expiration Date
1/8/2009
Suspend Date
Separation Date
Parent Company
CASCADE PACIFIC PAINTING LLC
Previous License
CASCAPP964PM
Next License
Associated License
Bond Information
Bond
Bond
Company
Name
Bond
Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
#1
DEVELOPERS
SURETY &
INDEM CO
744981C
01/01/2007
Until
Cancelled
$12,000.00
01/08/2007
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
JURVAKAINEN,
RANDY A
PARTNER/MEMBER
01/08/2007
Look Up a Contractor, Electric or Plumber License Detail
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
•
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CPCONCS933BH 06/03/2008
EX GYP. SD. CEILING
EX GYP BD. CEILING
SCALE: I /8" =I' -0"
12600 TENANT
SUITE 'A'
(4,500 S.E.)
50' -0"
I I
L
L
J
J
IT
I I
1I
it
1 I
1 1
1
1 1
11
u
I►
1
/. REPLACE EX 5U5P. ACOUSTIC CEILING
W/ NEW 2' X 4' MP. CEILING TO MATCH
EX GRID LAYOUT, HEIGHT 48' -6 RE -DROP
11
11
11
11
11
11
11
11
11
—=
11
11
11
11
IN EX LIGHT FIXTURES. MODIFY NYAC. EX
SPRINKLER PIPES LOCATIONS SHOULD WORK
BUT WITH NEW SEMI - RECESSED HEADS.
REFLECTED CEILING PLAN: REPLACE EX.
O' 1' 4' $' 16' 24' 32' 40'
SCALE 1 /8" = 1' -0"
LEGEND
6
WW1TGI -I
EXHAUST FAN 4 LIGHT
r
N4 SITE FLAN
SCALE: NONE
' SEPARATE PER
REQUIRED FOR:
le
96lectrical
lumbing
Gas Pipi
City of Tukwil
E BpADING DIVISION
ail
li\
IBUILDING 'A' (13,441 S.P.)
OVERALL FLOOR PLAN
SCALE: 1/16"=1
c4E COMPLIANCE I
RIM COPY
Permit No.
plar review approval is subject to errors and omissions.
Approval o= construction documents
o o ts lr��
the violation of any adopted
o approved Field Copy and + viedged:
By
Date:
oe'
APPROVED
MAY 28 2O
City of Tukwila
BUILDING DIVISION
No than REVISIONS
9es shall be made to the scop
of work without prior approval of tECEiUI(
Tukwila Building Division. CI�v Q>~ TI�v1�
NOTE: Revisions will require a new plan submittal
and may include additional plan reviavv fees
VICINITY MAP
SCALE: NONE
APR 2 9 2000
PERMIT CENTER
SETBACKS
1
- - - -- -wi■
t..
0'1' a' 16' 32' 48' 64'
TAX PARCEL NUMBER:
BUILDING CODE:
BUILDING 'A' AREA:
SUITE 'A' AREA:
CONSTRUCTION:
OCCUPANCY GROUP:
ZONE:
SCOPE OF WORK:
REPLACE EX. MP. ACOUSTIC CEILING WIN NEW MATCH CEILING. NO CHANGE IN LIGHTING OR
BUILDING ENVELOPE. NEW HYAC AND MODIFY SPRINKLER HEADS TO SEMI - RECESSED WEADS.
5EPERATE PERMITS FOR HYAC, ELECTRICAL, AND SPRINKLER
' Ra _ ' � a� 10.41 • Li
1 IB
iPrian
.. •
•
=A i i' 30
' ' , 4, . r. � S200011,,-01
• • • . ?•
isinixra,or sac= :
110/12011:40SCP1011. fir. r - PA'B ,. 9i0IH Dpi'
'Mtn IOH p$�r . - i i•.2O MIT •
11R. 1. I9, 1 1�M: , . - r ,
49Ati +. ` gyp • 0 • nre in •. .ma
:1 T [rte • - : Y�F i
O11GI�; .� 'i '�' F. B35 ' 3- '.Pone MO .
Warn
14018130217. �ir::•Aw• -� o ••A` 0 '1 Illpa a t ,or
: '� RAID . OF !
:coat Gc R' - x:, 44 - ' r•07': .1F4
R ` 14. 1210 r .. ,
' NORZE 41112:4r •1 Jd A � ' * . :253 r P • '
von/for aiteiniwzm;
fig, em's aZ ■4orxc- nor Alcurriarcz 07 r . . .
' ' IKIArli 59.3:3'30' R '1 A� : *z .op 4#13.33 $$ffi'r •
=NICE •s , Ole S ag '.#r '� : for -341. a XoLt.01
smo T. Pr - b .0g- Itts.: I sx • itivitai, SAID lam am
Azao '1" • uomm2Filf SONO= or CAN. L '611' =S DOMI 8011 •
alma scoraeimaa • at •,i+ut• •or WE earn Dittatati
. To T E warz514 LICA OF 1111W12110? ABM OEscRtwOr
'='3iiT!CR. soars Do '3 B' RIM .6:11171704 07 159 ?Mar ' 1 -
'=.E2a.. P+c�prr. or s.op. .
•
s* 'lg • Its MY OP
•
SCALE I/16" = 1' -0"
0004800003
2006 IBC UJ/ WA STATE AMENDMENTS
13,441 SF
4,500 SF
Y -B FULLY SPRINKLED
B OFFICE* S -I STORAGE
C/LI (COMMERCIAL / LIGHT INDUSTRIAL)
L
•
•
.�.�
:5`'• ... - .. ....• •• .. • •
J
m
g LLI
Ch
003 03
N N
W
O X
a�
u) O
�
Q
Z "
O W "
ay 03
� V)O)
M :i#7 2 03 7 —
\ \Wkst~4 \documents \CAD \2002 \0225 IaREEFTenant Improvements \Tukwila Commerce Park \BLDG A \BLDG A 12600 (LUND) \T41.dwg, 4/29/2008 AM, Design3et 500 MAIN
NOTE:
1 EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED
TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN
AVERAGE OF I FOOT- CANDLE AND A MINIMUM AT ANY
POINT OF 0J FOOT- CANDLE MEASURED ALONG THE
PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION
LEVELS SHALL BE PERMITED TO DECLINE TO 01,
FOOT - CANDLE AVERAGE AND A MINIMUM AT MY PONT
OF a% FOOT- CANDLE AT THE END OF THE
MENCY LIGHTING TIME DURATION. A
MAXIMUM -TO- MINIMUM ILLUMINATION UNIFORMITY RATIO
OF 40 TO I SHALL NOT BE EXCEEDED.
2. EMERGANCY LIGHT FIXTURES TO HAVE BATTERY BACK UP TO
TO MAINTAIN REQUIRED LIGHT LEAVES FOR A MINIMUM 90 MINUTES.
1 THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL
AT ALL TiMES THE BUILDING IS OCCUPIED BE ILLUMINATED. SEE
FLOOR FLANS ON SHEETS A -I 4 A -2.
Suspended Ceilings
Suspended ceilings are to comply with the following codes and regulations
1. 2006 International Building Code (IBC) Sections 803.9 and 162.1
2. ASTM 0635 and ASTM 0636 (referenced in IBC 803.9). ASTM is an acronym for
American Society for Testing and Materials.
3. ASCE -1 Section 9.62.6 (referenced In IBC 1621.12). A5CE is an acronym for American
Society of Civil Engineers.
4. CISCA recommendations for seismic Zones 3 -4 (referenced In ASCE -1 Section
9.62.622). CISCA is an acronym for Cetltngs # Intesrior Systems Construction Association.
5. IBC 102.1 states, ' e, in any specific case, different sections of this code specify
different materials, methods of construction or other requirements, the most restrictive
shall govern. 114 re there is a conflict between a general requirement and a specific
reaquirement, the specific requirement shall be applicable."
6. Partial listing of requirements for suspended ceilings:
a. Only a heavy duty T -bar grid system shall be used. ASCE -1 Section 9.62.622 item a.
b. Width of the perimeter supporting closure angle (wall angle) shall be not Tess than 2.0
inches. ASCE -1 Section 9.621,22 item b.
c On two a dJacent sides, the grid shall be attad^sd to the wall angle. Pop rivets are
acceptable. On the other two sides, there shall be a inch clearance between the ends
of the grid and the wall. ASCE -1 Section 962.622 item b.
d. Stabilizer bars are required to prevent the spread of main beams and /or cross
toss. CISCA Guidelines for Seismic Restraint for Direct Hung Suspended Ceiling
Assemblies, Seismic Zones 3 4 4, May 2004, Installation Section, item 4.
e. Perimeter support (tail) wires are required within eight inches of the wall for all
edges. CISCA Guidelines for Seismic Restraint for Direct Hung Suspended Ceiling
Assemblies. Seismic Design Groups D/3 4 E/4, May 2004, installation Section, item 2.
r. Vertical hangers shall be No. 12 gage wire spaced at 4 feet on center. Three wire
tuns required. Within 1:6 out -of -plumb unless counter - sloping wires are providesd.
g. Lateral bracing is required: splay wire pods at 12 max. o.. and 6 max from walls.
CiSCA Guidelines for Seismic Restraint for Direct Hung Suspender) Ceiling Assemblies,
Seismic Design Groups D/3 4 E /4, May, 2004, installation Section, item 3, ASC 1 -02,
9.62,622, and City of Kent Policy require lateral bracing at all ceiling areas greaten
then 144 SF surrounded by walls that connect directly to structure above.
h Ceilings over 2500 square feet must have seismic separation Joints or full height
partition that breaks the ceiling up into areas not exceeding 2500 square feet.
ASCE -1 Section 9.62622 item d.
i. For ceilings without rigid bracing, sprinkler head and other penetrations shall have a
2.1nch in all horizontal directions* or, sprinkler had extension to have a swing Joint
that can accommodate I Inch of ceiling movement in all horizontal directions. ASCE -1
Section 962.622 item e.
J. Changes in telling plan elevation shall be provided with positive bracing. ASCE -1
Section 9.62.622 item f'.
k. Cable trays and electrical conduits shall be supported independently of the ceiling.
ASCE -1 Section 9.62.6.22 item g.
SPACER BAR., OR OTI-ER SUITABLE
SYSTEM, TO KEEP PERIMETER
COMPONENTS FROM SPREADING APART
314'
MIK A
4.12 GA WIRES WITHIN 2" OF
CROSS TEE CONNECTION
ARRANGED AT 90' FROM EACH
OTHER AND AT AN ANGLE NOT
EXCEEDING 45'. LOCATE
RESTRAINT PANELS AT 12' O.G. IN
EACH DIRECTION AND WITHIN 6'
OF EACH WALL.
1' UN-ATTACHED WALLS
1ALL ANGLE
` MN. 2"
NOTE:
ATTACH CEILINGS AND GRID TO WALL
ANGLE (MOULDING) AT TWO ADJACENT
WALLS VIA POP RIVETS.
NOTES:
FOR WALLS GREATER
THAN 8'- 0" IN
WiDTH WITHOUT AN
INTERSECTING WALL,
PROVIDE 12ga. WIRES
SPLAYED e 45 TO AN
EYE SCREW a ROOF
AND TOP OF WAL
ATTACH TOP RUNNER
TRACK TO CEILING
GRID WIT1-I 2 - +6
x 1 1/8" LONG
SCREWS AT 2' -0" O.G.
TYPICAL STUDS - 3 5/8 ",
256A STEEL a 24" O.C.
(FOR WALL INSULATION SEE
PLAN) 5/8" GYP. BD. EA.
SIDE (FLUSH FINISH).
TYPICAL WALL HEAD TO SUSPENDED CEILING
SCALE: 1- 1Ro2l'
NOTE:
SUSPENSION WIRES TO BE 12 GAGE AT 4'
O:C. W/ ATTACHMENT DEVICES CAPABLE
OF SUPPORTING 100 POUNDS.
HANGER 4 PERIMETER WIRES MUST BE
PLUMB WITHIN 1 IN 6 UNLESS COUNTER
SLOPING WIRES ARE PROVIDED
I) MAIN BEAMS TEES AND CROSS TEES MUST BE
HEAVY' DUTY W/ CONNECTION STRENGTHS aF 100
POUNDS IN COMPRESSION 1 TENSION.
2) CEILING AREAS GREATER THAN 1000 SF MUST HAVE
LATERAL FORGE BRACING VIA DIAGONAL SPLAY
WIRES, LIMITING MOVEMENT TO LESS THAN 1/4 AT
POINT OF ATTACHMENT.
1•111■■■■■■■■■■■■■ ■ ■f' 7 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■A
4 11 r
1)
0 RESTRAINED CEILING DETAILS (MEETS IBC 2003 SEC 1621 A410 CISCA 3 -4 ASTM C635 A5111 C636 ASCE 1-02)
SCALE
3) LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO
MAIN AND CROSS TEES_ AND IF OVER 50, MUST BE
INDEPENDENTLY SUPPORTED.
4) PARTITIONS GREATER THAN 6' TALL NEED
INDEPENDENT BRACING vIA SPLAY WIRES
(SEPARATE FROM ANY OTHER WIRES). PARTITIONS
6' OR LESS NO ATTACHMENT IS REQUIRED.
5) SPRINKLER HEAD PENETRATIONS MUST HAVE 2"
OVERSIZED TRIM TO ALLOW I" MOVEMENT IN ALL
DIRECTIONS.
6) MANUFACTURER CERTIFICATION OF COMPONENT
PEtFORMANCE AND PERIODIC SPECIAL INSPECTION
OF ANCHOR SYSTEM IS REQUIRED.
FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC
SEPERATION JOINT OR FULL HEIGHT WALL PARTITION
THAT BREAKS THE CEILING SHALL BE PROVIDED.
8) ALL CROSS TEES SHALL BE CAPABLE OF
CARRYING THE DESIGN LOAD WITHOUT EXCEEDING
DEFLECTION EQUAL TOY,m OF iTS SPAN.
9) ALL WIRE TIES ARE TO SE THREE TIGHT TURNS
AROUND ITSELF WITHIN 3 INCH.
r
SEE REFLECTEDAIL
CEILING PLAN �1
RE E' ED Rje
COMpL
MAY 2 81111-
/ 0 fIa --
.
- 2,s+
TYPES
w
0
w
0
8
th
N O)
CZ 03
CD re)
CO 03
Ili CO
N
co co
0 0
C4 CV
W
X
Q.
z
\ \Wkst-4 \documents \CAD \2002 \0225 RREEFLTenant Improvements \Tukwila Commerce Park \BLDG A \BLDG A 12600 (LUND)\T- 1.dwg, 4/29/2008 10:16:50 AM, Designlet 500 MAIN.pc3