Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-258 - EMERALD CITY DANCE - TENANT IMPROVEMENT
EMERALD CITY DANCE 652 STRANDER BL EXPIRED 07-15-09 D08 -258 Parcel No.: 0005800037 Address: 652 STRANDER BL TUKW Suite No: Tenant: Name: EMERALD CITY DANCE Address: 652 STRANDER BL , TUKWILA WA Owner: Name: BC PARTNERS LLC Address: 175 PIEDMONT , ASHLAND OR 97520 Phone: Contact Person: Name: BILL BERTCH Address: PO BOX 476 , RENTON WA 98057 Phone: 425 - 271 -0082 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: ENRICHED DESIGNS INC Address: 12920 SE 95TH WAY , NEWCASTLE WA 98056 Phone: 425 - 255 -5467 Contractor License No: ENRICDI12809 DESCRIPTION OF WORK: TENANT IMPROVEMENT doc: IBC -10/06 Cityiif Tukwila • DEVELOPMENT PERMIT Value of Construction: $20,000.00 Fees Collected: $685.13 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D08 - 258 Issue Date: 06/05/2008 Permit Expires On: 12/02/2008 Expiration Date: 07/03/2009 D08 -258 Printed: 06-05 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: doc: IBC -10/06 City dOTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Print Name: CA/vPire -4 Permit Number: DO8 - 258 Issue Date: 06/05/2008 Permit Expires On: 12/02/2008 Date: ola WJ W " I hereby certify that I have read and :� ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio t performance of wor am authorized to sign and obtain this development permit. Signature: Date: ( �I 08 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -258 Printed: 06-05 -2008 Parcel No.: 0005800037 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 652 STRANDER BL TUKW EMERALD CITY DANCE 1: ** *BUILDING DEPARTMENT CONDPI'IONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -258 ISSUED 05/02/2008 06/05/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. doc: Cond -10/06 D08 -258 Printed: 06-05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IPC 906.3) (NFPA 10, 3 -2.1) 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: No point in a building may exceed the maximum exit access travel distance listed in Chapter 10, section 1015, Table 1015.1 of the International Fire Code and International Building Code. 23: Minimum widths of corridors shall be maintained in accordance with Chapter 10 of the International Building Code and the International Fire Code. 24: In Group B and M occupancies, the minimum clear aisle width shall be determined by the occupant load served, but shall not be less than 36 inches. (IFC 1013.4.1) 25: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 27: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 28: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 29: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access doc: Cond -10/06 D08 -258 Printed: 06 -05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 30: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 nun) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 31: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 32: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 33: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 34: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 35: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 36: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 37: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 38: U.L. central station supervision is required. (City Ordinance #2050) 39: All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. (City Ordinance #2050) 40: All exterior components of sprinkler systems should be painted RED. This includes: Post indicator valves (PIV), outside stem and yoke (OSY), wall indicator valves (WIV), and Fire Department connection (FDC). (City Ordinance #2050) 41: Fire department connections (FDC's) shall be oriented in the direction of fire apparatus access, have a 4 foot clear space in front and to the sides of the connection, be appropriately signed and protected from potential vehicular damage. 42: The fire department connection (FDC) shall have a downward angle bend between 22.5 and 45 degrees, with a 5 -inch Storz doc: Cond -10/06 D08 -258 Printed: 06-05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us fitting(s) and Knox FDC locking Storz cap. (NFPA 13- 6.8.3) (City Ordinance #2050) 43: The height of fire department connections (FDC's) shall be 36 to 48 inches above grade. 44: Fire department connections (FDC's) shall be located within 50 feet of a fire hydrant. 45: For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant is within 150 feet of a building and so that no point of a building (around its perimeter) is greater than 300 feet from a hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. (City Ordinance #2052) 46: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 47: An approved manual fire alarm system is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 48: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 49: Local U.L. central station supervision is required. (City Ordinance #2051) 50: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 51: When the control panel is located inside a room, the door to the room shall have a sign with one -inch letters which reads "Fire Alarm" or "Fire Alarm Control ". (City Ordinance #2051) 52: Dedicated fire alarm system circuit breaker(s) shall be equipped with a mechanical lockout device. (NFPA 72 (4.4.1.4.2.1)) 53: In areas that are not continuously occupied, automatic smoke detection shall be provided at each fire control unit(s) location to provide notification of fire at that location. (NFPA 72) 54: The reset code for the fire alarm panel or keypad shall be 1- 2- 3 -4 -5. The reset code shall not be changed without approval of the Fire Marshal. The reset code should be permanently posted at the keypad. (City Ordinance #2051) 55: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 56: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 57: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 58: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 59: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110.26(A) thru F(2)) 60: Each circuit breaker shall be legibly marked to indicate it's purpose. (NEC 110 -22) doc: Cond -10/06 D08 -258 Printed: 06-05 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 61: Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (IFC 605.3.1) 62: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 63: Fire doors, fire windows and fire dampers shall have a label or other identification showing the fire protection rating. Such label shall be approved and shall be permanently affixed. (IBC 715.3 Table 715.3, 715.4, 716.3.1 Table 716.3.1) 64: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of International Building Code 803. 65: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 66: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 67: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 68: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 69: Every building shall be accessible to Fire Department apparatus by way of access roadways with all- weather driving surface of not less than 20' wide and 13'6" vertical clearance. Access roads in excess of 150' shall be provided width an approved turn- around area. Access shall be within 150' of all portions of the buildings. (City Ordinance #2047) 70: There shall be no enclosed usable space under stairways in an exit enclosure, nor shall the open space under such stairways be used for any purpose. (IBC 315.2.4) 71: All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (IFC 503.1, 508.1) 72: Aboveground gas meters, regulators and piping exposed to vehicular damage due to proximity to alleys, driveways or parking areas shall be protected in an approved manner. (IFC Ch. 312, sec. 312.1 thru 312.3) 73: Combustible material shall not be stored in boiler rooms, mechanical rooms or electrical equipment rooms. (IFC 315.2.3) 74: These plans were reviewed by Inspector 515. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 75: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: Cond -10/06 * * continued on next page ** D08 -258 Printed: 06-05 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us _Lszuz_QQ-(2-&d-aN ave. Le, Date: 7 ( LD ( Cj � D08 -258 Printed: 06-05 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Mailing Address: f® SOX 1 176 9 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: tQ —et, 7 Site Address: 524)- 671z0 &v© .- ivr --h• Suite Number: G25 F}- Floor: F Tenant Name: gi'vi 2f3L>> G / Y PRA4 1 Property Owners Name: PAQT J 1Z L LZ.. Mailing Address: a e/0 7 2v9 ✓ ©6fl- 61-1/0 Name: & /U-, TG E -Mail Address: fi7Gk3. - 2 Building Per- No, Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. o ject No. • (Fara use ony) Trig WI L I� City New Tenant: Yes ❑ .. No G�7 - 1'1e3 State Zip Day Telephone: "7 ZS - 2? l -co Z 1ZtU W74 State City Fax Number: Zip GI (Co ad Gas P'iping.(pg'- Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Company Name: 1 ‘ ) // Mailing Address: Contact Person: E -Mail Address: Company Name: /ii Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: \Applications'Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh State State State Zip Expiration Date: ECT OF RECORD All plans must be wet stamped by Architect of Record City Day Telephone: Fax Number: Zip — AllYpia ins must be wet stamped by Engineer of ll'tecord Zip Page 1 of 6 DING PERMIT 1NFORI�'"" 4 ION - 206 -4'1 -3670 Will there be new rack storage? ❑ Yes P3 Number of Parking Stalls Provided: Standard: Q: \Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh vide All Building Areas in Square Footage Below Valuation of Project (contractor's bid price): $ 24 OICO Existing Building Valuation: $ Scope of Work (please provide detailed information): in'-r ic'2 1 104 eecjv -rr Sit T1 No If yes, a separate permit and plan submittal will be required. Floo oxy Acct Att da Idi Addition to Existing Structure Type of nstruction per IBC U Type of Occupancy pe a 1BC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ,y2' No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 34 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x II " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 CATION NOTES Applic. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT, BUILDING OWNER OR AUTHO,RIZED AGENT: Signature: Print Name: giLi_Z-1Gr� I Date Application Accepted: r . 1. Mailing Address: PD >e 1 /76' Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Date Application Expires: Staff In" t ipJ,s: I( -2- -O is. application Date: "2 1-03 L 5-Z71- 2 t/u14 ?gas State Zip Page 6 of 6 Receipt No.: R08 -01958 Payee: CW DESIGN, INC. ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 2015 415.13 RECEIPT Parcel No.: 0005800037 Permit Number: D08 -258 Address: 652 STRANDER BL TUKW Status: APPROVED Suite No: Applied Date: 05/02/2008 Applicant: EMERALD CITY DANCE Issue Date: Initials: JEM Payment Date: 06/05/2008 11:06 AM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000/322.100 410.63 000/386.904 4.50 Total: $415.13 • Payment Amount: $415.13 3292 06/05 9711 TOTAL 415.13 doc: Receipt -06 Printed: 06 -05 -2008 Parcel No.: 0005800037 Address: 652 STRANDER BL TUKW Suite No: Applicant: EMERALD CITY DANCE Payee: CW DESIGN ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Cash 270.00 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Receipt No.: R08 -01470 Payment Amount: $270.00 Initials: BLH Payment Date: 05/02/2008 01:59 PM User ID: ADMIN Balance: $415.13 Account Code Current Pmts 000/322.100 1.87 000/345.830 268.13 Total: $270.00 • Permit Number: D08 -258 Status: PENDING Applied Date: 05/02/2008 Issue Date: 1925 05/02 9710 TOTAL 270.00 doc: Receiot -06 Printed: 05 -02 -2008 COMMENTS: // oal ii`-‘2_,91erif c715fir'Aife a T .A. .z.»44Ivh _ 4 puie t 61.4-2-ht.)— ✓�/ _/ i i) J4f/4J7 44 A /,w N'�Gd y leeiri 4- / / 1-) . Al Fo(14 • ..?) la Project: ccmf/O --Li.3 &79 Type of Inspection: !/t//e1i Addr ss: Date Called: Special Instructions: Date Wanted: a.m. i3 r 49P- Requesr: Phone No: ��!! ,213( .6'74 . 5 77 l Retain a copy with permit L VI 0 �S -c2 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION vz, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 0 Approved per applicable codes. (Receipt No.: INSPECTION RECORD .00 REINSPECTION FE • REQUIRE '. Prior to inspection, fee must be id at 6300 Southcenter : vd., Suite 00. Call to schedule reinspection. 'Date: Corrections required prior to approval. R' Project: 04A Type o , A ` Address: (0.c - S ( M0 �-,r 6 . Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone 2$ -2S5 - 54V ) INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 c o - Z 5' PERMIT NO. (206)431 Approved per applicable codes. ❑ Corrections required prior to approval. / COMMENTS: ti (11 73r/ 2 Act Date: /L $ : x.00 REINSPECTION FEE QUIRE . Prior to ins • ection, fee must be id at 6300 Southcenter Blv.., Suit= 100. Call to schedule reinspection. Re / ipt No.: 'Date: COMMENTS: V .sb 44 A- pp. 6J 49 Type of Inspection: 4/ * ( ( J gi/ rr Address: 65,7 iv\ C--_ "t d/ • (. Date Called: q pt Special Instructions: � _A (- jze -:AJ/ JT 1..) ...1_ Requester: Phone No: x ( 7_ , . t & 4 ` - C� G -'k`fc £ E.- ( r (� C A I► 1 / Proj J � . 74r /K // '/ /_ 7 Type of Inspection: 4/ 14 6, Address: 65,7 7 1217 R Date Called: q Special Instructions: ate W nted: 1..) ...1_ Requester: Phone No: / /V5-- t INSPE ON NO. INSPECTION RECORD Retain a copy with permit d 2sP, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Ins!) actor' �/ r /t , Date: — ( - f ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4•■ _ - ,.. -n... ..._ • e..., Project: ' '� ►-1 D C{ DAN' C.. Type of Inspection: �� (is sc /i i in .v � na Address: A ,.) c )t R Address: a t Suite #:' Con ct Person: J li Irk. Special In' ructions: Phone No.: 6 45 - ii qc Needs Shift Inspection: • b Sprinklers: . Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 0 • "•e1s<i : tit'. :-' 7�srrz1i7s7 ,'E•.t ki INSPECTION NUMBER II Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 414 Andover Park East, - Tukwila, Wa. 98188 - - 206= 575 -4407 . Word /Inspection Record Form.Doc • 1/13/06 PERMIT NUMBERS Corrections required prior to approval: Hrs.: COMMENTS: 55 I, 51` f i (JJ 5 &ova o•D 19 ifs 1. 4iN dei fL. a. IV> b rvinie /,q I Me P.1 4, T.F.D. Form F.P. 113 Inspector: S i Date: ///6: $80.00 R FEE RE You will receive an invoice from e C ity of Tukwila Finance Department. Call to schedule a reinspection a y&L • • j 06 -03 -2009 BILL BERTCH PO BOX 476 RENTON WA 98057 RE: Permit No. D08 -258 652 STRANDER BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/15/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, c Bill Rambo Permit Technician xc: Permit File No. D08 -258 Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 11 -03 -2008 BILL BERTCH PO BOX 476 RENTON WA 98057 RE: Permit No. D08 -258 652 STRANDER BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 12/09/2008 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. fer Marshall, t Technician Permit File No. D08 -258 • city of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 May 21, 2008 Sincerely, Bifi Bertch CW Design, Inc. B Allen Johannessen, Building Department Brenda Holt, Permit Coordinator City of Tukwila 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Development Application Number D08 -258 Emerald City Dance — 652 Strander Blvd Dear Allen Johannessen and Brenda Holt, C DESIGN, INC. Listed below are the responses to your correction notice dated May 14, 2008. • P.O. Box 476 • RENTON, WA. 98057 425-271-0082 (OFFICE) • 206- 948 -7094 (OFFICE) • 425-228 -8699 (FAX) Item #1 Added occupant load calculation to sheet Al. Exit door swing incorrectly shown on original submittal. Item #2 Added emergency lighting to reflected ceiling plan (sheet A2). Item #3 Labeled "common path of egress" and minimum width of path to TI Plan on sheet A2. Item #4 Added note regarding mechanical alterations to TI Plan on sheet A2. Please feel free to contact me with any questions you may have at 425 - 271 -0082. CORRE TIO LTR # t02r Z 1 of 1 RECEIVED MAY 22 2008 PERMIT CENTER f May 14, 2008 Bill Bertch PO Box 476. Renton, WA 9$053 RE: CORRECTION LETTER #1 Development Application Number D08 -258 Emerald City Dance — 652 Strander BI Dear Mr. Bertch, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 - 133 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, uk k ik' Brenda Holt Permit Coordinator encl File No. D08 -258 • city of Tukwila P:1Permit Center\Correction Letters\2008\D08 -258 Correction Ltr #I.DOC wer Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo • Date: May 13, 2008 Project Name: Emerald City Dance Permit #: D08 -258 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Occupant count based on the square footage indicated for this tenant is over 49 occupants. Retail area is base on 30 sq ft per occupant and office business areas are calculated at 100 sq ft per occupant resulting in 51 occupants for this tenant space. Where the occupants exceed 49, two means of egress shall be required, doors shall swing into the direction of egress and emergency lighting shall be required. Please revise the plan to show doors swinging into the direction of egress. (IBC 304, 309, Table 1004.1.1, 1015.1) 2. Show emergency lighting along path of egress on the reflective ceiling plan. Emergency egress lighting shall comply with egress illumination where emergency pathways have sufficient illumination to meet the 1 foot -candle requirement at the walking surface leading to the exit discharge doorways. (IBC Section 1006 & 1025.8) 3. Identify the common path of egress travel that leads to each exit. Width of egress path shall be a minimum of 36 inches without obstructions. (IBC 1014.4.1 & 1014.4.2) 4. Mechanical alterations shall require a mechanical permit. This is for your information only. If mechanical diffusers are relocated or are to remain, please indicate with a note on the plans. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP I, ACTIVITY NUMBER: D08 -258 DATE: 05 -22 -08 PROJECT NAME: EMERALD CITY DANCE SITE ADDRESS: 625 STRANDER BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Bui d' g Non Public Works 5 -0 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route Documents/routing slip.doc 2 -28 -02 REVIEWER'S INITIALS: Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: El Planning Division ❑ Permit Coordinator DUE DATE: 05 -27 -08 DATE: Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required DUE DATE: 06-24 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -258 DATE: 05 -02 -08 PROJECT NAME: EMERALD CITY DANCE SITE ADDRESS: 652 STRANDER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter #__ Revision # After Permit Issued g Pudic Works Structural ... �.� o -ate DEPARTMENTS: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-06-08 Complete R Comments: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Prevention Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions n Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 DATE: DATE: Planning Division Permit Coordinator Not Applicable No further Review Required n n DUE DATE: 06 -03 -08 Not Approved (attach comments) TV( Permit Center Use Only ( p� CORRECTION LETTER MAILED: 6 Departments issued corrections: Bldg i Fire ❑ Ping ❑ PW ❑ Staff Initials: • REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 512'-108 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 111 Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: EMERALD CITY DANCE Project Address: 652 Strander BI Plan Check/PermitNumber: D08-258 `/ ZS- Zf I - c Summary of Revision: APD i✓) '17-1562t) 1 - 1 •T' sG ft..D I NG Contact Person: Bill Bertch Af 6tM T CENTEF+ Sheet Number(s): "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on S-)-1-0.C( \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Phone Number: RECEIVED CITY OF TUKWIL.A MAY 2 2 2008 License Information License ENRICDI12809 Licensee Name ENRICHED DESIGNS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601070096 Ind. Ins. Account Id 59001300 Business Type CORPORATION Address 1 12920 SE 95TH WAY Address 2 City NEWCASTLE County KING State WA Zip 98056 Phone 4252555467 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/29/1988 Expiration Date 7/3/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date LINDBERG, NIKKI L 01/01/1980 LINGBERG, PENNY J PRESIDENT 09/29/1988 YANTZER - TRISTA, KAREN SECRETARY 09/29/1988 LINDBERG, CHARLES C VICE PRESIDENT 09/29/1988 Look Up a Contractor, ElectriGn or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information I Bond I Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ENRICDI12809 06/05/2008 i i i i \ \ 1 \ 1 1 1 \ EXISTING SUILING \ \ \ \ \ EXISTING PARKING EXISTING PARKING / EXISTING BUILDING EXISTING BUILDING • l • • ' • • • 1 1 • 1 • irn Site Plan i 1 Permit No. FILE COPY Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is a w dged: By CY4' A CD geA Date: �, f City of Tukwila BLELOINCI SEPARATE P FOR REQUIRED 'Me er Electrical WPlumbing trGas piping City O Tukwila gtiIl- NG DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees ZONING PARCEL NO. LEGAL DESC. SITE ADDRESS CODE(S) CONSTRUCTION TYPE OCCUPANCY GROUP ENERGY CODE ANALYSIS OCCUPANT LOAD DESIGNER CW DESIGN, INC PO BOX 476 RENTON, WA 98057 PH (425) 271 -0082 FX (425) 228 -8699 Sheet No. Al A2 Project Data TUC 000580 -0037 MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25 -23 -04 - BAAP ON WLY R/W LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HWY ENGR STA 160 +00 TH FR SD POB ALG SD WLY R/W LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -07 -31 W 35 FT FR C/L AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81 -07 -31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19 -33 -22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF SD NLY R/W LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LN S 87 -12 -48 E 194.01 FT TAP ON WLY R/W LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08 -52 -29 E 165.06 FT TO TPOB 652 STRANDER BLVD TUKWILA, WA 98188 2006 INTERNATIONAL BUILDING CODE (IBC) V -N B NO CHANGES TO THE EXISTING ENVELOPE RETAIL = 1 OCCUPANT /30 SF 1,390 SF / 30 = 46.33 (46 OCCUPANTS) OFFICE = 1 OCCUPANT /100 SF 483 SF / 100 = 4.83 (5 OCCUPANTS) TOTAL OCCUPANT LOAD = 51 Scope of Work INTERIOR TENANT IMPROVEMENT ON SUITE #652 A „ Project Contacts GENERAL CONTRACTOR ENRICHED DESIGNS, INC 12920 SE 95TH WAY NEW CASTLE, WA 98056 PH (425)255 -5467 FX (425) 271 -1456 Drawing Index Description SITE PLAN / PROJECT DATA T.I. PLAN / REFLECTED CEILING PLAN CORRECTION LTR #_ JUL 15 2009 008 2S8 RECEIVED MAY 2 2 2008 PERMIT CENTER 1 cw DESIGN, T.C. www.cwdesigninc.com F.O. Box 476 Renton, WA 98057 425 -271 -0082 (Office) 206 -948 -7094 (Office) 425 - 228 -8699 (Fax) REV. DATE 05/21/00 A 0 1 ci N O 0 E 00 00 00 0) Ca 0) t Lc V) C6 O w 0 (ROJECT NO.: 08066 DRAWN BY: WJB /KRB DATE: MAY 21, 2008 SHEET: Al WALL MOUNTED EMERGENCY LIGHTING (LITHONIA ELM2) WALL MOUNTED EMERGENCY LIGHTING (LITHONIA ELM2) EXIST GWB CEILING COMMON EGRESS PATH IREI LEGT!r? CEILING FLAN SCALE: I/4 ".I' -0" O!TAIL SCALE: 1/4 " =1' -0" (EXISTING CONDITIONS) (I) LAYER 5/8" GYPSUM WALL BOARD EA. SIDE TYP. 22 GA. 6" MTL. STUDS TYP. • 24" O.G. PNEUMATIC IMPACT ANCHORS • 24" D.G. (TYP) @ CONT. RUNNER NEW 4" RUBBER BASE TYP. NEW CARPET FLOORING TYP. EXIST. FLOOR SYSTEM EXISTING 2x4 ACOUSTICAL CE ILL ING PANEL SUSPENSION EXISTING 2x4 3 -TUBE FLOURESCENT LIGHT FIXTURES (TYP UNO) 4" MTL. STUD BRACING @ 24" O.G. TO STRUCTURE ABOVE. STAGGER rr BRACING DIRECTION. rr o ri /i - // i .1.11N EXIST. SUSPENDED CEILING SYSTEM 1 (5) # 12 TEK SCREWS EA. CONNECTION 22 GA. 6" MTL. STUDS TYP. 24" O.G. 5/8" GYPSUM WALL BOARD EA. SIDE - EXISTING SIDEWALK TO PARKING LOT EXISTING WALL 23' -0" NOTE NO MECHANICAL ALTERATIONS NEW WALL TO BE CONSTRUCTED (METAL STUDS) EXISTING WALL 48 "x48" OPENING OFF I GE 4S3 5F NEW 36" DOOR NEW WALL TO BE CONSTRUCTED (METAL STUDS) 5ATH 56 SF EXISTING ADA COMPL IANT BATH �/ / ////l / / /1 // ////l///// /////./1/ /..17.4/! /,1 T.I. FLOOR FLAN SCALE: 1/4" =1' -0" EXISTING 36" EXIT DOOR E PI JUL 15 2009 boa - isE3 RECEIVE MAY 2 2 2008 PERMIT GENIE DESIGN, INC. www.cwdesigninc.com P.O. Box 476 Renton, WA 98057 425 -271 -0082 (Office) 206 -948 -7094 (Office) 425 -228 -8699 (Fax) REV. DATE a) E a) Q L co cc) N Q c=rf 1 ef5 1 N LC) Cdi C.0 1 co 0 g i= o !;" QFQ7U W � '�o�`�a�� o �'W LL ����aa�� �� o °$���o�a � �� ¢ ¢ wo - ��� = W F�F y a'UZ VJ Vla'U¢OZ�OW �ovQM °z�a c9Z(n W QZpc7°Ug Za�wYrnww OC]vi��TF 04 Q�FJULLMOW 0 ;17::!! W Q W J �� mT :aa =- Ji 0U�OxQF - v�u'UZ Jp hIM d a y s g r* ETI L P U °Vii u Oz�Ua (PROJECT NO.: 08066 DRAWN BY: WJB / KRB DATE: MAY 21, 2008 SHEET: A2