Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-265 - ITT TECHNICAL INSTITUTE - TENANT IMPROVEMENT
ITT TECHNICAL INSTITUTE 12720 GATEWAY DR D08 -265 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Tenant: Name: ITT TECHNICAL INSTITUTE Address: 12720 GATEWAY DR , TUKWILA WA Owner: Name: RREEF AMERICA REIT II CORP/ Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Phone: Contact Person: Name: GALEN HOLDEN Address: 2221 5 AV , SEATTLE WA 98121 Phone: 206 441 -1449 Contractor: Name: UNIPLEX INC Address: 753 18TH AVE E , SEATTLE WA 98112 Phone: 206 -323 -4320 Contractor License No: UNIPLI *211B3 doc: IBC -10/06 CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D08 -265 Issue Date: 08/11/2008 Permit Expires On: 02/07/2009 Value of Construction: $200,000.00 Fees Collected: $3,288.00 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: IIIB Occupancy per IBC: 0008 Expiration Date: 11/15/2008 DESCRIPTION OF WORK: TENANT IMPROVEMENT TO PART OF THE 1ST AND 2ND FLOOR FOR ADMINISTRATIVE OFFICES AND TECHNICAL TRAINING USE. TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND COSNTRUCTION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, OUTLETS, AND FINISHES. * *continued on next page ** D08 -265 Printed: 08-11 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: WZI — Date: 8- `V V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presum construction or the neriormance of woak. Signature: Print Name: doc: IBC -10/06 City JP Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D08 -265 Issue Date: 08/11/2008 Permit Expires On: 02/07/2009 o give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this development permit. Date: — // v 1 U5 /V This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -265 Printed: 08 -11 -2008 Parcel No.: 2716000070 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 12720 GATEWAY DR TUKW ITT TECHNICAL INSTITUTE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -265 ISSUED 05/07/2008 08/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D08 -265 Printed: 08-11 -2008 • City of Tukwila 16: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (ffC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Doors shall swing in direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. (IFC 1008.1.2) 21: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 22: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: There can be no storage under stairs unless the following conditions are met. The walls and soffits within enclosed usable space under enclosed and unenclosed stairways shall be protected by 1 -hour fire - resistance -rated construction, or the fire- resistive rating of the stairway enclosure, whichever is greater. Access to the enclosed usable space shall not be directly from within the stair enclosure. There shall be no enclosed usable space under exterior exit stairways unless the space is completely enclosed in 1 -hour fire- resistance -rated construction. The open space under exterior stairways shall not be used for any purpose. (ffC 1019.1.5) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (ITC 1011.1) 28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having doc: Cond -10/06 D08 -265 Printed: 08 -11 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 29: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 30: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit panic hardware on rated fire doors. (IFC 1008.1.9) 31: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 32: Exits shall not pass through kitchens, storerooms, restrooms, closets or spaces used for similar purposes. (IFC 1013.2) 33: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 34: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 35: Combustible material shall not be stored in exits or exit enclosures. (IFC 315.2.2) 36: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 37: All sprinlder system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 38: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 39: All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. (City Ordinance #2050) 40: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 41: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 42: Per Tukwila Municipal Code a fire watch is required any time a fire sprinkler or fire alarm system is impaired. The doc: Cond -10/06 D08 -265 Printed: 08 -11 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http :• / /www.ci.tukwila.wa.us fire watch shall be maintained until the system is restored. Contact the Tukwila Fire Prevention Bureau at 206 -575 -4407 for detailed fire watch requirements. 43: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 44: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 45: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 46: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 47: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110.26(A) thru F(2)) 48: Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110 -22) 49: Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (ITC 605.3.1) 50: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 51: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 52: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D08 -265 Printed: 08-11 -2008 Signature: Print Name: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. 7 - / /11 doc: Cond -10/06 D08 -265 Date: 1/4 g ordinances governing or local laws regulating Printed: 08 -11 -2008 CITY OF TUKIA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.Wa. u,s 'SITE LOCATION Site Address: I 2:1 2 D 1:)12,U\/E, Tenant Name: ITT TECH t C4L t Kati MT'FS Property Owners Name: F 'l — (,p %.4.rt: t AAA_ Mailing Address: 1pODt C R-t AE-t- M I] TtAK -KNIT A levA State CONTACT PERSON -= who do we contact when your permit is ready to be issued Name: 1* O LAD Mailing Address: 222.k A R, E -Mail Address: E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** GENERAL CONTRACTOR'INFORMATION `- (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1 Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: I\ /t . NL 4f- / Ec' tit A 'r Mailing Address: 2221 3'h AVE- Contact Person: G Et ( D t,(,pW • •• • A. V • .1: • Building At No. Mechanical Permit No.:. Plumbing/Gas Permit Public Works Permit ;No • Project"N • ti .' �. King Co Assessor's Tax No.: 21 lt X'O -- O(> -b(rl D--OCo Suite Number: Floor: I 4-ZLet New Tenant: ❑ Yes No City Day Telephone: 2/9Q I -14 s ^ct w• ci%[ZI City State Zip Fax Number: 2cCo -4-4(44— -I 43(p. 1 City Day Telephone: Fax Number: Expiration Date: vv 6 1'6 \ City telp e (Fop; office use only)° State • Zip Zip State Zip Day Telephone: 20(0 -f. 4-(! I 4 -9 ax Number: 20 0 ` - t i t 1 — 1 - 1--(at ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: \Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page I of 6 } ' ' 4 • Existing . Interior Remodel • Addition ta_: t . - isting • Structure it•:' ..1 • • • • • ...a . :: ; w ' •.: ': New , Type of ,' : :' Construction •per IBC ' •: - . Type. of Occupancy per' •• IBC •1 &`.Floor )1 V Floor . :a• ! f' / X 3r Floor . . Floors - • . thru ' Basement Accessory Structure* Attached Garage .Detached Garage Attached Carport Detached Carport :• , .. Covered Deck ..z;_ • Uncovered Deck • BUILDING PERMIT INF(IATION - 206 - 431 -3670' Valuation of Project (contractor's bid price): $ 2_c, ocmc Existing Building Valuation: $ Scope of Work (please provide detailed information): re_AA ,vv4- i1ANVCD\L- i + r pa r$ Cse L cks) —) a-' VA l_r►a•ti �ta� , onS / ckco6' S Yp t OcvS , Gt� 2 av Will there be new rack storage? ❑ Yes Provide All Building Areas in SquareQFootage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes QAApplications\Forms- Applications On LineO -2006 - Permit Application.doc Revised: 9 -2006 bh S.. No If yes, a separate permit and plan submittal will be required. Compact: Handicap: El No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: gi Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If ''yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safely ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 • PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZE Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Mailing Address: 222_ A t R__, Date Application Accepted: osloa -!os Q:\Applications\Pomss- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: Date: s/-i / 0 Day Telephone: 219 (0 - 44( 14 -49 `1$lz.a City State Zip I I 101 Staff Initials: Page 6 of 6 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: ITT TECHNICAL INSTITUTE Receipt No.: Initials: User ID: Payee: R08 -03690 JEM 1165 UNIPLEX, INC. TRANSACTION LIST: Type Method Payment Check ACCOUNT ITEM LIST: Description doc: Receiot -06 PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Descriptio 18309 Amount Account Code 000/345.830 RECEIPT 60.00 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $60.00 Payment Date: 11/05/2008 03:16 PM Balance: $0.00 Current Pmts 60.00 Total: $60.00 D08 -265 ISSUED 05/07/2008 08/11/2008 Printed: 11 -05 -2008 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: ITT TECHNICAL INSTITUTE Receipt No.: R08 -02896 Payee: UNIPLEX INC ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Initials: WER Payment Date: 08/11/2008 01:34 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18261 1,994.50 Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Total: $1,994.50 Permit Number: D08 - 265 Status: APPROVED Applied Date: 05/07/2008 Issue Date: Payment Amount: $1,994.50 1,990.00 4.50 5933 08/11 9710 TOTAL 1994.50 doc: Receipt -06 Printed: 08 -11 -2008 Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: ITT TECHNICAL INSTITUTE Receipt No.: R08 -01516 Initials: User ID: Payee: JEM 1165 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us MARVIN STEIN & ASSOCIATES, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 26328 1,293.50 RECEIPT Account Code Current Pmts 000/345.830 1,293.50 Total: $1,293.50 Permit Number: D08 - 265 Status: PENDING Applied Date: 05/07/2008 Issue Date: Payment Amount: $1,293.50 Payment Date: 05/07/2008 01:42 PM Balance: $1,994.50 2104 05/07 9711 TOTAL 1293.50 doc: Receipt - 06 Printed: 05 -07 -2008 Project: _ / / 7 /0Yhiv Type of Ins�gction: v ,f-, .�� / Address: // QC) c f7//°G4' ,!)/ Date Called: Special Instructions: Date Wanted: Requester: Phone No a06- 2 D- 4 /c/75 . INSPECTION RECORD Q �S Retain a copy with permit 006 _ INSPECTION N0. PERMIT NO. r CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Approved per applicable codes. Corrections required prior to approval. COMMENTS: eceipt No.: 4--P9 (del le) pi e 6 ( Z /may ii Date' 0 REINSPECTCONFE 'EQUIR . Prior to inspection, fee must at 6300 Southcenter BL/i., Su' a 100. Call to schedule reinspection. 'Date: Project: . r • Type of Inspection: rc4/') /7 / /7''!/./'l'o9 / Address: / 2 7 7 0 GHT6 J' > Date Called: >? _ Special Instructions: Date Wanted: oZ - a . ,.. . .. Requester: Phone 6 --2 V -W _ INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 M8-26 PERMIT NO. (206)431 -3 7 OMME Date F1INSPECTION FEE : EQUIRED. P or to inspection, fee m . st be at 6300 Southcenter Blv , Suite 10 Call to schedule reins, ection. proved per applicable codes. Corrections required prior to approval. Project: T Type of Inspection: `-/ •■92 //t)G •\ Add ress: �� e Date Called: Special Instructions: Date Wanted: �t'� t s — �."-- 6 . Requester: Paoli -2Sa INSPECTION RECORD Retain a copy with permit PERMIT INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- COMM S: eipt No.: REINSPECTION FEE RE c UIRED. Pr}}' . r to inspection, fee ust be at 6300 Southcenter Blvd., ' ite 100fCall to schedule reinspection. Date: Approved per applicable codes. ❑ Corrections required prior to approval. Project , Type of Inspectio • ! Address: r 24Zo (,4 , Date Called: Special Instructions: Date Wanted: 2 i'/_ W O `' a.m. p.m Requester: Phone _N) — V? O '/.5" INSPECTIO NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: �` • -— ;`7 • P - r�l of / �j�i- ��� i.-40 (ti iii VIP r.I1 Inspector: Date D ` El Approved per applicable codes. Corrections required prior to approval. LI $60.00 INSPECTIO EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: - 1 -- - e Type of Inspection: A ` (lei A ress: P-27 iO444 Usti Ze Called. Special Instructions: l( Date Wanted: 2. d -Et , p.m. Requester: Phone No: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 proved per applicable codes. Corrections required prior to approval. COMMENTS: 7 (9 GU g&tO ft4 , eceipt No.: 1 Date1- Z d .00 REINSPECTION FEEtEQUIRED. I rior to inspection, fee must be aid at 6300 Southcenter Blv'�t11., Suite 10 .. Call to schedule reinspection. 'Date: Project: "II cwt' Type of Inspection: r R Aev.‘iIQG., Address: 170 CA'A'Iw►4L-1 .b2 Date Called: • Special Instructions: Date Wanted: 1 3 - Q5 p.m. Requester: Phone No: 2_0(0 - 2 CO- 4! 73 I7 ■ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION a. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I]uApproved per applicable codes. COMM ENTS: 71 i f�`� Re p t No.: F Aim me, Inspec VA $64 00 REINSPECTION FEE ' QUIRE pad at 6300 Southcenter Blvd., Suite e INSPECTION RECORD Retain a copy with permit Date* Date: be -2raS PERMIT NO. Corrections required prior to approval. f* /qpi • . Prior to inspection, fee must be 00. Call to schedule reinspection. Project: , of Inspection: �i� .19 / 7 �c9/ 1V) 4 � X1 Address: /2 7Z0 6,q Date Called: ., ) Special Instructions: Date anted: ,eCrp„ /- ,2 -6cr Requester: Phone No: ,ao -256- /l/7-5' INSPECTION NO. INSPECTION RECORD Retain a copy with permit 8 - -z6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION a 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: e' ew__ TO oil 7 (NI p, � 00 REINSPECTION FEE REQUIRED. P for to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100 Call to schedule reinspection. Receipt No.: 'Date: Proi ct: Type of Inspection: ,i_i.s w 0.f IL I f\A _1__T 1 -C h NI ell ( Address: 12 2 &too LaA 9 Date Called: Ti) -. k Special Instructions: Date Wanted: I? Me/ 10 e �a rrr- Requester: - Phone No (-N 7 COMMENTS:! � • i tb 5 Ti) -. k k 4c6(10 . , ty.i - A yv "..e N. V ) •)e : e s -E 19 ;. k' I I ; , (-L& 4 1 / 4 ( f) •---. . • .4 • a t lnspe or: 1 Date: r l 10 El Approved per applicable codes. Rec '�ipt INSPECTION RECORD Retain a copy with permit 'Date: RMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 1� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to lE� $60. 0 REINSPECTION FEE EQUIRE . Prior to inspection, fee must be paid. at 6300 Southcenter Blv ., Suite 100. Call to schedule reinspection. Project: T -r - i" 71 0Ic' l ( Type of Inspection: T> 4 rvi /A) Aadr ss 1 - ?2o (p AT W l L Date Called: Special Instructions: • Date jan a.m. Requester: Phone No 2q 7- 5 f cr INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: c 3 vzC, l ax , ti ��` 4 J � $ • I. t 0 REINS ECTION FEE R DIRE' . Prior to inspection, fee must be p . • at 6300 Southcenter Blvd., 100. Call to schedule reinspection. Receipt No.: 'Date: t� Pr— o}e Type of Inspection: —ct: T Address: (� Tli�� :� r� Date Called: Special Instruction,: 7 OC'G 4 Cr : a.m. equester: Phone No: / -C — . -- L L /7 _..— C. INSPECTION NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit j - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION i' (206)431 -3670 Corrections required prior to approval. COMMENTS: r Inspector: Date: 0 $58.00 REIN PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: 46 r 4 � '. Awn m -t A— ttee6ti0Lt.—' � Ns ti u .Y • "�sr• f r Yi Project: T Type of Inspection: / 7ao ')l / Ad resd s: �+ / ? 20 ( ,4, Date Called: Special Instructions: Te71-4 ac Date Wanted: ,f� //— G—/ O a.m. LP's` Requester: E A 4� i Phone No: f t INSPECTION RECORD ' ' Retain a copy with permit INS ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: p4 $60.00 EINSPECTION FE MIRED. Prior to inspection, fee must be paid at 6300 Southcenter vd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: t �' e Address: t Z 17,0 69/1.41 4: Date Called: Special Instructions: 02.11 � 2 � 3 Date Wanted: it -r 3 V a.m. Requester: Phone ( ^ 2 qQ - -M INSP CTION NO. INSPECTION RECORD Retain a copy with permit Z(?5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: ('> J +'1 F her—® 'gets d) ne;I) J p -aloe C ylivise � ti L In (ire • Inspects : Date: El t0.0 i REINSPECTION FEE QUIRE . Prior to inspection, fee must be paid f� . t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: COMMENTS: Type of Inspection: A-yai ou e.4 zoi.pl e p e--( :'. -( I. `,Al . /ac 1 j:/\ A � I .. . ruu4 r =f- A c,J 41 6-ou er • - - Wit. . f 4.W c .s<-, -i 2 f h (3 A-k -qtt f /.3 USMf /ArPr 0 r 4 (.) i A L " i / aP__ r1e-? ; t ) ,N Vt kkf 6 Pe-- 1 to v. r b 1 J f c c. (.`.n 7 /fr L (.• 1.44 1 (:,1 er lit 4 �1(Afi Project: A^ -t-r- �-�- r. 1 ���' ` . Type of Inspection: W.B. a . Address: • 1217.v 6, ) t 4 -7 4!.. Date Called:••'""•'" " . . • .-- Special Instructions: a l 4 o I (- 0 ( 4 Date Wanted: " i 0 ' 3d - dY p.m. Requester: Phone No: Z? (0 - 2 © --441.5 Approved per applicable codes. /2Z 008 (05 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 for to aooroval. Inspector: Date: ,o _3d_ r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Pro : J I ! Type o spection: . 1 - 1 d a"... ✓l� Address: / /ow low Ai Date Called: DR Special instructions: Date Wanted:/ (ate f1 �� i Requester: Phone No: 2.0 G - 2/0 - INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: .(�4r'�F I 1A�I i 139 C L- !r (1 Z t. k1 is r ) it Inspect 'Date: J — ve. n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: ' Type TP - . '7;,t i'r;: 1,,7 of Inspection: 6. . A , Address: 1 2 ' 7 2.0 644" " J' Date Called: Special Instructions: r Id v 07 , (7 4 - o f Da t �¢ .s � O � Date Wanted: / 0 ^ 3 - o < ' . . Requester: Phone N o: I (� 2 5v 4? ar pproyed per applicable codes. INSPECTION RECORD Retain a copy with permit INSP CTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 b0-2L5 PERMIT NO. r {A. (206)431 -3670 U Corrections required prior to approval. COMMENTS: OK p ons& : vA ?Pi _ r/ ., Date:' EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: • COMMENTS: 6 2 4d/ // 4"11 / (1[l • a ._...e- /i e4 / A rr4e , k) ' / 1" /) /, i -rrl .7474Y 4 7 /'�/DrJ Address: ., /Z 7 ?U 6'.4- qr,(/ .It-j Ly Date Called: Special Instructions: Date Wa t d: /� — /" U e p.m. Requester: Project: • Type of Inspection: ( CU7r.'L T^v '1 ineir w T / T Gi .we 4 / Address: ., /Z 7 ?U 6'.4- qr,(/ .It-j Ly Date Called: Special Instructions: Date Wa t d: /� — /" U e p.m. Requester: Phone No // : ? . 0 ./ 5 3 !6 26 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -370 Approved per applicable codes. /24 REINSPECTION FEE R'OUIRO ..Prior to inspection, fee must be at 6300 Southcenter Blvd. Suite 100. Call to schedule reinspection. eipt No.: Date: w -, - '' Date: Corrections required prior to approval. / COMMENTS: , CO phi s tkh4 I i lJ ( , - f1 ,/AIec 1 1 � F si , ,? A i c.) 1...d e. i CI o vu _ Rt Z Li + t S W e �vSz � i a vwke 1 - . t 3 t}1 4 I Sv 7 i . ' A ' 1 — i (O ► Q P O (i 1 L (IJ 4 I c.. Ate' ypy - I' ✓ (th L/ .. (e c1�s.i dUo4;O,v U Special Instructions: U In tV kit\ �� f ( oo Date red: i + 1 v� m. v6 Pro'ect: Type of Inspection ' LL Address: 1 2 & ATW ' (I Date Called: D2 Special Instructions: U In tV kit\ �� f ( oo Date red: i + 1 v� m. r. Ph Requester: o vh ne U N ��2T r l U "(- j -ref /5 'INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. a Corrections required prior to approval. REINSPECTION FEE REQUIR 6300 Southcenter Blvd., Suite PERMIT NO. (206)431 Date: 011 is � dP D . Prior to inspection, fee must be 100. Call to schedule reinspection. Receip o.: IDate: COMMENTS: ,.-3 Type of Inspectio : , 4/0` F✓a 44, h.+. Address: l ^ Date Called: 4i fU (Uve� r- P rr Date Wa ed - I i 7 : 5 � v Corr; /� ) , o-- /,vG 7/ .4- -iv, / v '` Phone No: .2 — 7fo- y' /7S` R 1 4 "/Z'2 / P a 7/ s'ir-et.✓S cs'Diy r �d W° �/ f`4l /H 7 a -, L r //,,,-Z. / ›e._ Project , c rr TIC A. Type of Inspectio : , 4/0` F✓a 44, h.+. Address: l ^ Date Called: Special Instructions: Date Wa ed - I i 7 : 5 � v a.r p.m. Requester: Phone No: .2 — 7fo- y' /7S` INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3617 Approved per applicable codes. ❑ Corrections required prior to approval. $58.00 REIN CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: 0 .etiaistttrletko iF?ee! ,t4V - Net - -- i'a i° "+ ,` '+ "�1°•. '_ " ..�..es.w''tY+ - • - Project: _ Sprinklers: I Type Inspection: I ii L Address: r . 7 a 0 Suite #: /0d Cite. L i- a.- Contact Pgpo n: Special Instructions: Occupancy Type; Phone db ' °- _ 3/,_0098 Needs Shift Inspection: _ Sprinklers: �' ' Fire Alarm: r Hood & Duct: 1 - /V Monitor: LJ4. Pre -Fire: ! e knits: N Occupancy Type; INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East. Tukwila, Wa. 98188 206- 575 -4407 WI -Approved per applicable codes. n Corrections required prior to approval. COMMENTS: A- - i tetL OiAly • • r l V ti Inspector: i . Flrs.. I Date: 2/ $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a' reinspection. • Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form 113 t Project: -t-r\ Sprinklers: Type of Inspection: -P Hood & Duct: Address7. id -, Suite #: 614 e. i„,s Contact Person: ,. - Occupancy Type: Special Instructions: Phone No.: . • Needs Shift Inspection: • Sprinklers: Are Alarm: Hood & Duct: Monitor: Pre-Fire: , Permits: Occupancy Type: INSPECTION NUMBER ri Approved per applicable codes. INSPECTION RECORD Retain a copy with permit - CITY OF TU'KWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila •Wa: 98188 206-575-4407 COMMENTS: At",) D iV/A To SE C-0/y,» cpr c),47 ) 4 • Date: 'Hrs.: rrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an. invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspettion Record Form.Doc . 1/13/06 . • PERMIT NUMBERS TiF.D, FOrm.RP, 113 . COMMENTS: Sprinklers: 4 , Type of nspection: . qu I PA- Address; OW. G tgvi- Suite #: I Konitor: Contad Person: i V\I • A — A P1. ,A-a,44v-- Special Inlr'uttions: . P Ako• a- 1A e 404' 1 OIL ''' . 0 . . - p •••I • . - - . • . i I Sr) P,, o4., . . • .,. : .• , . . i ..... . N.... t.......7•Anedtr I . . I e 4 . . ' I ... sr - ;. - 1 ' • Yt6Sict: TIT . Sprinklers: 4 , Type of nspection: . qu I PA- Address; OW. G tgvi- Suite #: I Konitor: Contad Person: i V\I • A — A P1. ,A-a,44v-- Special Inlr'uttions: . . - Phone No.: Ci - 2, Needs Shift Inspection: Sprinklers: 4 , Fire Alarm: Hood & Duct: Konitor: Pre-Fire: . Permit: • ccupancy Type: i• S PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206-575-4407 INSPECTION NUMBER . ri Approved per applicable codes. INSPECTION RECORD Retain a copy with permit )PB • 2.105 tt,I4 Corrections required prior to approval. • I Inspector: Date: /21 /061 atQA1 - $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department.. Call to schedule a reinspection. Word/Inspection Record Form.Doc . T.F.D. Form RP. 113 Project: Sprinklers: • Type of Inspection: Address: 1. -7 Suite #: 0 r2 Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: • Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Word /Inspection Record Form.Doc • INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. 1/13/06 of - - ro PERMIT NUMBERS • Corrections required prior to approval. Insp& ;tor: Date: //Z 1 I Hrs.: • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: oft . -- ,A.4‹ 6, 4 • Project: Type of Inspection: v S Pr - Sprinklers: - Address: /0 7 Suite #: /06 'Dec_ Contact' Person: Special Instructions: Monitor: Phone No.: Needs Shift Inspection: Sprinklers: - Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: • .r Occupancy Type: ;4=AmmucatrAm~ s 7 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FI DEPARTMENT '8— 6, PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. TI Corrections required prior to approval. COMMEN © /c A II 1 I et . tAb -b E /t... 2 gm-1J P oi ' P -42 n. Inspector: .,, Date: H $80.00 REINSPECTION FEE REQUIRED. You.will receive an invoice from the City of Tukwila Finance Department. .Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: /TT` Ty of Inspection: CY. - £-r Sprinklers: . Address: /23 20 akm /f Suite #: 17. 1 Contact Person: .apt +' _:; Hood.& Duct: Monitor: Special Instructions: . Phone No.: 206 . --- /S/6. (4400M Needs Shift Inspection: Sprinklers: . Fire Alarm: Hood.& Duct: Monitor: Pre -Fire: Permits: • - Occupancy Type: . INSPECTION NUMBER .0" per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 1/13/06 bog- 2.4c PERMIT NUMBERS CITY OPTUKWILA. FIRE DEPARTMENT 444 Andover Park Tukwila, Wa. 98188 Y 206 -575 -4407 Corrections required prior to approval. COMMENTS: ke Yo 4/670./1/5 d CAS - 6 1' '1 Inspector: Naliti / Date: r Hrs.. . e $x0.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 143 , Project: Xn— Type of Inspection: tt f A) ' 4 "iv ! Y J s I Address: 1 2.7LO Gaie-4...44 Suite #: Contact Person: 6,+r Special Instructions: Phone No.: (2'r3 / / 074) Needs Shift_Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: • 4 • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Doe -2‘5 8 -FW PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa: 98188 206- 575 -4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r'r •- 41)9 e l A e.44.4 )) J * 3 et,miegefi}eoQ, r Inspector: Sc 5 / Hrs.. / Date: /01/7/08' $80.00 REINSPECTION FEE REQUIED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: 2'1 Type of Inspection: gen e-.y-e-.40- y /.Jh¢ jje, Address: / z 7 Z v G4/C1? Suite #: pit . Contact Person: fob^ '�'? Special Instructions: Phone No.: a 4 . 2-90 yi - � Needs Shift Inspection: Sprinklers: Fire Alarm: _ _ Hood & Duct: Monitor: Pre -Fire: Permits: ! Occupancy Type: 2. INSPECTION NUMBER n Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 1/13/06 J-. CITY OF TUKWILA 'FIRE DEPARTMENT Do 8- Z4 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 C orrections required prior to approval. COMMENTS: //tee -14. Arber /13/21 4AG.l P'nn ,Fit.,,-ec sit 7 f�9e���'7r ►i.t�l L.1 4 5 - i (. • • nspector: SG) f,$ Date :. j /sA Hrs.: • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: ,a'?T Sprinklers: , Type of Inspection: A7/4- x314211 'n 4.d Address: / 2 7z , Suite #: Ga } €�•, -i az. Contact Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: , Fire Alarm: Hood & Duct: IIonitoP Pre -Fire: Permits:` p Occupancy Type: .1 3 INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. +' Corrections required prior to approval. COMMENTS: 0 _ 41 T "Qe/dlG 1 t o� w inspector: je Si • I Date: ,v,, e . $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: 77"" Sprinklers: Type of Inspection: Spa amiz LEY - Address: /2 9 Suite #: 1on Ciennivoto Contact Person: Special Instructions: Occupancy Type: Phone No.: Need s Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: e'lYgrw�: t INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 • Approved per applicable codes. COMMENTS: _.�. Q)012— -- oit— - (7 A5� �— Corrections required prior to approval. 4 ,,- g u la /1-4 WALL / 5 12. Date: gin I L Hrs.: $8b.00 REINSPECTION FEE REQUIRED'. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection: Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P, 113 COMMENTS: Sprinklers: Fire Alarm: P b V , c S c■ t 4R . C \ t P j c> •r Rf' t ' 4- ai.iCaX it. fve w e vi 4' mil. tAl 5 A O r e o, a r . ta N, Ak a 9.3.G, 3 be. , Contact Person: =-�'. ''C0.. c P--Mw +s C r A- fi - A ..✓' ' /%40.a e / o € - ..s +n C7 p rr 4 w+ (/S )- tat f r - . P .. (,., t . ,. . 7( 0 5 . . Scope - +.,0 a r ,2 lioolp F/ I5 C1.,,,, d 2.. e Ora .1 k e. Gtd.1 t \ e 5 a 4- c-+.... e ‘,,d, 5P/; (4 k. le °" LeS ai" SSG,- ,.,.4l Ar. ea cc", \s' & , Ali P/4- /3 q. 3.6 .3 Ai I o o C c>vC? .. Project: ----.. Sprinklers: Fire Alarm: Type of Inspection: 6!?P le_ Address: 1 Z Zo co, w; F+ Suite #: A`/ be. , Contact Person: =-�'. ''C0.. c P--Mw +s C r A- Special Instructions: Phone No.: 4/ i j g- 1 - '4-6, f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF, TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. VI Corrections required prior to approval. Date: 7 � 0 H $80.00 REINSPEC1 ON FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department, Call to schedule a reinspection. Word /Inspection Record Form.Doc October 24, 2008 Re: Permit # D08 -265 Project Name: ITT Technical Institute 12720 Gateway Drive Tukwila, WA 98168 Dear Mr ..Iohannessen: . _ Marvin Ste sociates,LLC planning design Allen Johannessen, Plans Examiner City of Tukwila, Department of Community Development 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 This is a response to the Building Division Review Memo sent to Marvin Stein & Associates dated October 17, 2008. Please use this letter in conjunction with the revised drawings we have resubmitted, Permit Revision #3, dated October 24, 2008. The following is our response to your comment #1 after our telephone conversation. 1. We have added a note onto the cover sheet of the drawings clarifying the intent & basis for changing the corridor rating as requested. These are all part of Revision #3, dated October 24,2008. Galen Holden MARVIN STEIN & ASSOCIATES, LLC 2221 Fifth Avenue Seattle, Washington 98121 (206) 441 -1449 Fax (206) 441 -4361 Email: marvinstein @isomedia.com r October 17, 2008 Galen Holden 2221 5 Av Seattle WA 98121 RE: CORRECTION LETTER #1 — Revision #1 Development Application Number D08 -265 ITT Technical Institute —12720 Gateway Dr Dear Mr. Holden, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator encl File No. D08 -265 apartment of Community Development Jack Pace, Director • P:\Permit Cen ter \Correction Letters \2008\D08 -265 Corr Ltr #1 - Rev #1.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 ® Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 e Fax: 206 - 431 -3665 • Building Division Review Memo Date: October 17, 2008 Project Name: ITT Technical Institute Permit #: D08 -265 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The revision indicated to remove all references to one hour construction for corridors wall, doors, ceilings etc. Please provide documentation to indicate the intent and on what basis it is necessary for changing the corridor ratings. Changes to notes shall be clearly identified on the plans and clouded. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. June 6, 2008 • • Marvin Ste sociates,LLC planning design Allen Johannessen, Plans Examiner City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 RE: Permit # D08 -265 Project Name: ITT Technical Institute 12720 Gateway Drive Tukwila, WA 98168 Dear Mr. Johannessen: This is a response to the Building Division Review Memo sent to Marvin Stein & Associates dated May 28, 2008. Please use this letter in conjunction with the revised drawings we have resubmitted, Permit Revision #1, dated June 5, 2008. The following are responses to your list of comments after our telephone conversation: 1. We have added a note to our Standard Tenant Sound Partition Detail that this detail is to be the equivalent to one hour construction; and that any new corridor and lobby walls are to be built to match this detail. 2. For the first comment, we have clarified that one of the doors you referenced (our door #202) is a 20 minute rated relocated door, and the hardware set would also require a closer (so the two doors referenced are essentially the same type w/ same hardware); the other door & hardware are new. For the second comment, we have changed the door type (our door # 200) to a one hour rated door smoke sealed with an automatic closer. 3. We have reiterated on our reflected ceiling plans (lighting plans), that the emergency pathway lighting that exists must be maintained per code, new areas of work must also comply, and the actual lighting locations need to be depicted on the electrical engineers plans. 4. The resubmitted four plan sets are wet stamped and signed. Sincerely 1 Galen Holden MARVIN STEIN & ASSOCIATES, LLC 2221 Fifth Avenue Seattle, Washington 98121 (206) 441 -1449 Fax (206) 441 -4361 Email: marvinstein @isomedia.com ft May 28, 2008 Galen Holden 2221 5 Av Seattle WA 98121 RE: CORRECTION LETTER #1 Development Application Number D08 -265 ITT Technical Institute —12720 Gateway Dr Dear Mr. Holden, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, encl fer Marshall it Technician File No. D08 -265 • city of Tukwila Department of Community Development Jack Pace, Director P:\Permit Center\Correction Letters \2008008-265 Correction Ltr #1.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Date: May 16, 2008 Project Name: ITT Technical Institute Permit #: D08 -265 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide details that identify wall partition types for the corridor walls and lobby separation walls. (IBC Section 708) 2. The doors referenced on the second floor to the hall way are inconsistent with type of rating. In addition the door to the lobby from the hall corridor shall be a one hour door, smoke sealed and shall be provide with an automatic closer. Please revise door details to meet type of construction. (IBC Section 715) 3. Identify emergency lighting and illuminated exit signs along path of egress on the reflective ceiling plan for the portions of hallways altered. Provide documentation on the plans to indicate emergency lighting and illuminated exit signs shall be maintained along the paths of egress. Emergency egress lighting shall comply with egress illumination where path of egress shall have sufficient illumination to meet the 1 foot -candle requirement at the walking surface leading to the exit discharge doorways. (IBC Section 1006) 4. Provide plan sets that are wet stamped and signed by a registered design professional. (IBC 106.1) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 - 265 DATE: 10 - - PROJECT NAME: ITT TECHNICAL INSTITUTE SITE ADDRESS: 12720 GATEWAY DR Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 X Revision # 1 After Permit Issued D PARTMENTS: Public Works Complete Comments: APPROVALS O CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2-28-02 4 DAdO3 a1i003 111Nli3d • PLAN REVIEW /ROUTING SLIP Approved with Conditions Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ ❑ Structural ❑ Permit Coordinator DUE DATE: 10 -28-08 Permit Center Use Only. • =;� "' `'' � f� 1 • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R TING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: DATE: Planning Division Not Applicable u DUE DATE: 11-25-08 Not Approved (attach comments) ❑ Permit Center Use Only • CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -265 DATE: 10 -10 -08 PROJECT NAME: ITT TECHNICAL INSTITUTE SITE ADDRESS: 12720 GATEWAY DR Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: /0 Bui g Division Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Please Route TUES/THURS ROUTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 I PERMIT COORD COPY/ PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete n Structural Review Required C n n No further Review Required DATE: DATE: Planning Division Permit Coordinator DUE DATE: 10-16-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 11-1 3-08 Approved r u Approved with Conditions n Not Approved (attach comments) Permit Center Use Only h CORRECTION LETTER MAILED: Vr1 DO Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initial& • PERMIT COORD c;uwY 1 PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: D08 -265 DATE: 06 -05 -08 PROJECT NAME: ITT TECHNICAL INSTITUTE SITE ADDRESS: 12720 GATEWAY DR Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Bui .(1 g Di Public Works 3 -a8 Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Permit Center Use Only. ,. INCOMPLETE LETTER MAILED: LE ETTER OF COMPLETENE MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Ti Planning Division No further Review Required DATE: DATE: Permit Coordinator C U DUE DATE: 06-10-08 Not Applicable ❑ n DUE DATE: 07-08-08 Not Approved (attach comments) Ti Permit Center Use Only '.' •• . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -265 DATE: 05 -07 -08 PROJECT NAME: ITT TECHNICAL INSTITUTE SITE ADDRESS: 12720 GATEWAY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: fAMpd 5 -1(1 1'I rI lI Build g Division 0Wr AT 6 Public Works Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: 2 -28 -02 �PERINIT COORD COPY a PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete d Incomplete n Structural Review Required Fl 51'I� IA & 5 Planning Division Permit Coordinator ❑ DUE DATE: 05-08-08 Not Applicable El Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 06-05-08 Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg '1 Fire ❑ Ping ❑ PW ❑ Staff Initials: _6 Documents/routing slip.doc n REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS I 10 - Summary of Revision: 10-t - t o,c , kg M L OC--�- fib f 014 Hv i ,12 Pio t,,15 k611.,o / - -)it• cow no n- wit-tkc,, pbbwS, t c.{i kr.,e, c - s Received by: '7 (/ 4-5'50- Y REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE. RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: PROJECT NAME: ITT I 'GUM I ICI `( PERMIT NO: W SITE ADDRESS: 12 r 1'20 f re0 1 1 Oa. ORIGINAL ISSUE DATE: T REVISION LOG (please print) (please print) (please print) (please print) (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: lc 2 4 O8 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ® Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ITT TECHNICAL INSTITUTE Project Address: 12720 Gateway Drive Contact Person: Galen Holden Phone Number: /1 )1., ° `r`-t; ( . / et Summary of Revision: 04,W i441 to Pi vd Plp' 11,l l- -- 4 6X/ z Git _ A t » C3 b0✓ v Aril" .4 wv2 ` &4 _ &Et/C4cav5' Sheet Number(s): �-.... z , ' 2 . � 3 : 1 4, 4./ ,q,2y "Cloud" or highlight al - - Received at the City of Tukwila Permit Center by Entered in Permits Plus on \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: DO8 -265 CR V OCT 2 4 Z008 PERMIT c. a s ltriRs Entered in Permits Plus on • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us p sxaa'1 -,�. '. REVISION SUBM.ITT,AL"' �a.Y,. q. o�.. v., n. Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10 HOlbeS Plan Check/Permit Number: 170 s -. <> I ❑ Response to Incomplete Letter # ❑ Resppnse to Correction Letter # ❑ Revision # after Permit is Issued Lld Revision requested by a City Building Inspector or Plans Examiner Project Name: \ TT 1 t.GU ,44.)+1 Project Address: L7, ?'LO a D2.ci Contact Person: COLE-4k.) �-•� -n( �t J P ile Number: p- �-� t-{ 1 - y 5 Summary of Revision: 17. 14-ov t. it 4(ei. t c iL o `f -✓t., c+ e a r, ✓" c CWL.2L A o✓ l nAN US t 0 sex, s r_r,au . AO C) ( A V tAhc -er Wins t id'-tee7" ¶ j' 4,1 -ri v urw..< ^ -,1-t,9 ap) JO k ri A 649 er i \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: CITY 0 nomiuk OCT 10 2008 PERMIT CENTER Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D08-265 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ITT Technical Institute Project Address: 12720 Gateway Dr Contact Person: 'A(, Summary of Revision: CIAO 1-44 n►.I 4241 Of 5(-AL I Poo ,\L7 &� ��-� e j ( q �-„,„ K\ I Sheet Number(s): 71 • L ) � T Z • 3 l TI-3.1 Tr • 4.1 C L. "Cloud" or highlight all areas of revision ilkcluding dateof revision Received at the City of Tukwila Permit Center by: ij kr Entered in Permits Plus on City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us littfQ \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director enAirir JUN 0 5 2008 PERMIT CENTER Phone Number: *)1€ ` Lill (' I � Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 24 AMERICAN FIRE ft CAS BKA53272032 11/01/2007 11/01 /2008 $1,000,000.00 11/01 /2007 23 OHIO CAS INS CO BK053272032 11/01/200611/01 /2008 $1,000,000.00 10/31/2007 22 OHIO CAS INS CO BKO(06) 53272032 11/01/200511/01/2007 $1,000,000.00 10/03/2006 21 WESTERN NATIONAL ASSUR CO CP300003566- 02 11/01/200411/01 /2005 $1,000,000.00 11/05/2004 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC 600965 10/01/2001 Until Cancelled $12,000.00 10/26/2001 1 CBIC 600965 12/30/1979 10/01/2001 $6,000.00 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LOtl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. UNIPLEX, INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNIPLEX, INC 2063234320 753 18TH AVE E SEATTLE WA 98112 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 600311862 ACTIVE UNIPLI *211B3 CONSTRUCTION CONTRACTOR 1/23/1979 11/15/2008 RMRENI`174ML GENERAL UNUSED Business Owner Information Name KENISON, RALPH B Role Effective Date 01/01/1980 Expiration Date Bond Information Insurance Information • • Page 1 of 3 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= UNIPLI *211 B3 08/11/2008 6 ACT ADJ AFF ALT ALUIVI APPROX BLDG BLKG B/S CAB CLR CLG CL COL CONC CONST CONT CPT CT DIA DIM DN DR DWG EA ELEC ELEV EXIST EXT FD FIN FLR FLUOR FR FT FURN GA GALV GL GWB HC HDWE HM HORIZ HT HVAC IN INCL INSUL INT JT LF l< 1-0 V UNLESS OTHERWISE NOTED NOTES: I. THRESHOLDS AT DOORW ACOUSTICAL CEILING TILE ADJACENT/ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELECTRIC(AL) ELEVATION (VIEW) EXISTING EXTERIOR FLOOR DRAIN FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH/ FURNISHING GAUGE GALVANIZED GLASS /GLAZING GYPSUM WALL BOARD HIGH HOLLOW CORE HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT LINEAL FOOT ABBREVIATIONS B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET (T- TIMER) B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET B/S WALL MOUNTED COMBINATION VOICE /DATA OUTLET B/S WALL MOUNTED DEDICATED VOICE LINE OUTLET B/S WALL MOUNTED JUNCTION BOX NOTE ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) ELECTRICAL LEGEND DOOR NUMBER TYPE OF DOOR A PAIR OF B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN OAK WOOD FRAME B. RELOCATED B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD FRAME. PROVIDE KICKPLATE IF NOT EXISTING. (TOUCH UP TO LIKE NEW CONDITION) C. NEW B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD FRAME (TOUCH UP TO LIKE NEW CONDITION) D. PAIR OF B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR OAK W0o9/\ FRAME WITH RELITE EACH SIDE. E. NEW B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD n FRAME. 9 EXISTING DOOR HARDWARE a. B/S LOCKSETAND CLOSER b. RELOCATED HARDWARE (VERIFY IF HARDWARE NEEDS TO BE RE- KEYED) c. B/S LOCKSER W/ AUTOMATIC CLOSER d. B/S DOUBLE DOOR HARDWARE W/ A AisMATIC SLIDE BOLT wAr 2 T TI T 1 - • 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. i N L \ U / N i WOOD FRAMES EQUAL SECTIONS OF GLASS SEE PLAN FOR OVERALL OD DIMENSIONS * GENERAL CONTRACTOR IS TO CONFIRM HEIGHT OF EXISTING DOORS AND MATCH NEW DOORS TO THAT ©© MAX MECH MFR MIN MISC MTD MTL NA NIC NO. ( #) NOM NTS OC OPNG OPP ORIG P.J. PL PLAM PLYWD PNL PR PTN R RB REF (R) REINF REQ REV RM RO SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP T.B.D. TEL TYP U.C. U.N.O. VCT VERT V.I.F. W/ W/O WC WD WS HAGER KICK PLATE MATCH EXISTING T 11 I DOOR & HARDWARE SCHEDULE MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PANEL JOINT PLATE PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION RADIUS RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TO BE DETERMINED TELEPHONE TYPICAL UNDER CABINET UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WITHOUT WALLCOVERING WOOD WORKSTATION SCHEDULED BASE 3/8" =1' -0" FIRST FLOOR AREA OF WORK 66' EGRESS PATH 3 I EXITING PLAN FINISH FLOOR II li VIII ■1I 8" x' CONT. 3 5/ 25 GA. TRACK W/ � _I MIN M 11Ii l� , N N N TA! 1411V 11I - 1 . LINE OF CEILING GRID --- BEYOND, SEE R.C.P. SUBFLOOR - - NEW CHAIR RAIL a N NEW RELOCATED COMMON PATH OF EGRESS = 75' MAX. 3 5/8" 5" EXISTING TENANT DEMISING PARTITION 121 CONSTRUCTION LEGEND 78' EGRESS PATH SEISMIC BRACING PER 91TI -1 5/8" FIRE TREATED PLYWOOD BLOCKING @ WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: 20" WIDE GALV. SHEET METAL (IN LIEU OF WOOD BLOCKING) 3 5/8" x 25 GA. GALV. STEEL STUD @ 16" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. 5/8" TYPE "X" GWB EACH SIDE PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS. SCHEDULED BASE CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN EMBEDMENT. NOTES: 1. SEAL BOTTOM OF WALL TO FLOOR SLAB USING ACOUSTICAL CAULKING CONTINUOUS BOTH SIDES. 2. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION. NEW CORRIDORS TO BE BUILT TO MATCH. STANDARD TENANT SOUND PARTITION NTS EXISTING BUILDING CORE/COMMON AREAS TO REMAIN UNALTERED EXISTING TENANT INTERIOR SOUND PARTITION: SEE DETAIL 71TI -1. U.N.O. = = = = EXISTING CONSTRUCTION TO BE DEMOLISHED. NEW TENANT INTERIOR SOUND PARTITION: SEE DETAIL 71TI -1. U.N.O. NEW OR RELOCATED B/S RELITE PARTITION TO MATCH EXISTING (SEE PLAN FOR DIM.) (TEMPERED SAFETY GLASS WITHIN 2' -0" OF DOOR JAMB AND LESS THAN 1' -6" SILL HEIGHT A.F.F.) EX -ACOUSTICAL BATT INSULATION ABOVE CEILING TO EXTEND 24" BEYOND EACH SIDE OF WALL LINE OF CEILING GRID BEYOND, SEE R.C.P. SUSPENDED ACOUSTIC TILE CEILING - DO NOT CUT CONT. 'L' METAL TRIM W/ PAPER WING COMMON PATH OF EGRESS = 96' MAX. SECOND FLOOR OFFICE: 6,180 SF / 100 = 62 CLASSROOM: 8,150 SF / 20 = 408 TOTAL OCCUPANCY LOAD = 470 FIRST FLOOR (470 + 157 + 157) 785 X .02 =157" 157 < (36 + 72 + 72) OR 180" : OKAY SECOND FLOOR AREA OF WORK NO CHANGE TO EXISTING SQUARE FOOTAGE ON EITHER FLOOR ACOUSTICAL CEILING SYSTEMS INSTALLATION EXITING & OCCUPANCY INFORMATION FIRST FLOOR OFFICE: 10,199 SF / 100 = 102 CLASSROOM: 6,248 SF / 20 w 312 LIBRARY: 675 SF / 50 = 14 ASSEMBLY: 641 SF / 15 = 43 TOTAL OCCUPANCY LOAD = 471 (2) EXITS REQUIRED (3) PROVIDED EACH FLOOOR SECOND FLOOR 470 / 3 =157 X 0.2 = 32" MIN. WIDTH AT EACH SECOND FLOOR EXIT VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' -0" O.C. OR NO. 10 GAUGE @ 5-0" O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE "PIN ". VERTICAL STRUT STABLING BAR @ 12' -0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. MAIN RUNNER AT 4' -0" O.C. -. VERTICAL STRUT FASTENED TO MAIN RUNNER. CROSS RUNNER INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9. IN ACCORDANCE WITH ASTM C 635 & 6. SUSPENDED CEILING SUPPORT DATA LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS - RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PINS THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SF. FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN, OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 IN. OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE AS REQUIRED BY CURRENT CODES. NORTH FOR INFORMATIONAL PURPOSED ONLY I SUSPENDED CEILING BRACING PA"N II% /III r L _J I I I-----1 EXISTING NON -RATED CEILING GRID AND TILES EXISTING RATED CEILING GRID AND TILES 131 LIGHTING LEGEND EXISTING B/S GYP BOARD CEILING EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE EXISTING 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED 1/32" =1' -0" EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN EXISTING B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO REMAIN NEW OR RELOCATED B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER EXISTING 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO BE REMOVED /RELOCATED EXISTING B/S RECESSED DOWN LIGHT NEW COVENTRY ARCHITECTURAL SERIES P2C PENDANT. AVIATION CABLE/COILED 10' CORD, DL12 CLEAR DOMED ACRYLIC LENS. B/S SWITCH (N =NEW) • B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN) N NEW NTS NTS 1 I VICINITY MAP SITE PLAN (2) #10 SCREWS REVEAL (PAINT BLACK) OR MATCH EXISTING. 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. 141 LIGHTING NOTES NOTES: 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 9 I TYPICAL PARTITION BRACING NO CHANGE TO BUILDING STRUCTURE OR USE METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SUSPENDED CEILING. SCHEDULED PARTITION LATERAL BRACING TENANT WALLS (w /o CASEWORK) NTS 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 2' MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) NORTH NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ABOVE TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (SEE FLOOR PLAN, TI -3) NTS EXISTING SITE DEVELOPMENT TO REMAIN AS IS NTS 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 1- 1/2 " =1-0" 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING OF 1 FT CANDLE @ FLOOR. 3. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. UNDER SEPARATE PERMIT 4. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF VA.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 6. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 7. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 8. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 9. RE- CIRCUIT SWITCHING AS NECESSARY. ALL NEW CLASSROOMS, INCLUDING LABS, TO HAVE DUAL SWITCHES. EACH SWITCH WILL CONTROL 50% OF THE LIGHT FIXTURES IN THESE ROOMS AND BE GROUPED INTO FRONT HALF AND REAR HALF OF ROOM. 5 10 SCOPE OF WORK: TENANT IMPROVEMENT TO PART OF THE FIRST AND SECOND FLOOR FOR ADMINISTRATIVE OFFICE AND TECHNICAL TRAINING USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, OUTLETS AND FINISHES. CONSTRUCTION TYPE: Ill -B, SPRINKLERED FIRST FLOOR AREA OF SUITE: +1- 17,736 SECOND FLOOR AREA OF SUITE: +/- 14,330 OCCUPANCY: B OFFICE BUILDING CODE: WASHINGTON STATE BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 -ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE LEGAL DESCRIPTION 7 GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER TAX ID NUMBER: 271600 -00- 0070 -06 SITE ADDRESS 12720 GATEWAY RIVE TUKWILA, WA 98168 PROJECT DIRECTORY: TENANT: ITT TECHNICAL INSTITUTE 13000 NORTH MERIDIAN ST CARMEL, IN 46032 CONTACT: ADAM MERKLE 317- 706 -9316 (PHONE) 317- 571 -0140 (FAX) DESIGNER: MARVIN STEIN AND ASSOC., LLC 2221 5TH AVE. SEATTLE, WASHINGTON 98121 CONTACT: GALEN HOLDEN 206 -441 -1449 (PHONE) 206- 441 -4361 (FAX) EMAIL - g.holden @marvinstein.com PROJECT INFORMATION 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS FOR THIS PROJECT. 3, CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4, B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD, AS DRAWN OR SPECIFIED IN THE CONTRACT DOCUMENTS. 5. BY L.L. @T.E. INDICATES "BY LANDLORD AT TENANT'S EXPENSE" 6. DIMENSIONS BETWEEN ELECTRICAL & TELEPHONE OUTLETS TO BE A MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 7. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS REQUIRED FOR THIS PROJECT. 8. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS, AS INDICATED HERE AND AS REQUIRED BY LOCAL JURISDICTIONS. 9. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, FIRE ALARM & SECURITY SYSTEM RENOVATIONS SHALL BE PROVIDED UNDER SEPARATE PERMITS. 10. ALL FURNITURE MOVING (INCLUDING SYSTEMS /CUBICLE FURNITURE) SHALL BE PERFORMED BY THE CONTRACTOR. GENERAL CONDITIONS PRICING SHOULD INCLUDE ALL COSTS TO HANDLE FURNITURE. 11. PAINT COSTS SHALL INCLUDE THE REMOVAL OF DRYWALL ANCHORS AND ANY PATCHING /REPAIR WORK FOR APPROXIMATELY 300 MISC. HOLES IN WALLS DUE TO ARTWORK/PROMOTIONAL WALL HANGINGS. 12. CONTRACTOR SHALL CREATE, UPDATE (WEEKLY) AND WORK WITHIN A PUBLISHED CONSTRUCTION SCHEDULE. 13. CONTRACTOR SHALL MAKE A REASONABLE EFFORT TO COMMUNICATE WITH THE DIRECTOR OF THE SCHOOL CONCERNING DAY -TO -DAY CHANGES IN THE WORK SCHEDULE, PARTICULARLY WHEN WORKING IN OCCUPIED SPACES. 14. CONTRACTOR SHALL MAINTAIN A PRACTICE OF DAILY CLEANUP, INCLUDING CONSTRUCTION DEBRIS, TOOLS, EQUIPMENT, AND MACHINERY. EXTRA CARE SHALL BE TAKEN TO CLEAN AROUND CONSTRUCTION DUMPSTERS. DUMPSTERS SHALL NOT SIT DIRECTLY ON ASPHALT OR CONCRETE, NOR SHALL THEY BE PLACED ON SOIL. PLYWOOD SHALL BE USED AS A BARRIER BETWEEN DUMPSTER BEARING POINTS AND HARD SURFACES. 15. NEW MATERIAL SHALL BE STACKED IN A 'NEAT AND ORDERLY' FASHION, AWAY FROM HIGH TRAFFIC AREAS AND OCCUPIED SPACES, 16. IF NECESSARY, CONTRACTOR SHALL PRODUCE AND MAINTAIN ON -SITE STORAGE CONTAINERS. CONSTRUCTION RELATED MATERIAL AND EQUIPMENT SHALL NOT BE STORED IN OCCUPIED ITT SPACES. CORRECTION GENERAL NOTES TI -1 COVER SHEET & DETAILS TI -2 FIRST FLOOR DEMOLITION PLAN TI -2.1 SECOND FLOOR DEMOLITION PLAN TI -3 FIRST FLOOR CONSTRUCTION PLAN TI -3.1 SECOND FLOOR CONSTRUCTION PLAN TI -4 FIRST FLOOR REFLECTED CEILING PLAN TI -4.1 SECOND FLOOR REFLECTED CEILING PLAN TI -5 FIRST FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -5.1 SECOND FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -6 FIRST FLOOR FINISH PLAN TI -6.1 SECOND FLOOR FINISH PLAN TI -7 ELEVATIONS AND DETAILS 15 I DRAWING INDEX BUILDING OWNER: RREEF 16000 CHRISTENSEN RD SUITE 101 TUKWILA, WA 98188 CONTACT: NANCY ANDERSON EMAIL: nancy.anderson @rreef.com CONTRACTOR: T.B.D. Permit Na . Fe O Y Pity review approval Is subject to c and onIssions" Approval of construction document does not authcre the violation of any adopted code or penance. R clipt of approved Feld Copy an conthions is a> ' noiedgcd: 8y �c9 City of Tula 1 REVISION N ... ___ \ PO' RECEIVED CITY OF TUKWILA OCT 247008 PERMIT CENTER THIS PROJECT WAS INITIALLY SUBMITTED FOR PERMIT UNDER 2006 IBC. HOWEVER, MUCH OF THE ORIGINAL CONSTRUCTION WAS DONE UNDER OLDER CODES IN THE '90'S. IN RESPONSE TO EARLY CONVERSATIONS WITH THE CITY OF TUKWILA, THE INTENT WAS TO COMPLY WITH THOSE OLDER CODE CONSTRUCTION REQUIREMENTS WHERE ONE HOUR RATED CORRIDORS, CEILINGS, DOORS, ETC WERE ORIGINALLY CALLED FOR. IN THE FIELD DURING CONSTRUCTION, IT BECAME APPARENT THAT MANY OF THE ONE HOUR COMPONENTS THERE HAD NOT BEEN MAINTAINED WELL OVER THE COURSE OF OCCUPANCY WITH REMODELS, MAINTENANCE, ETC. THEREFORE, AFTER MORE RECENT CONVERSATIONS WITH THE CITY, THE PERMIT FOR THIS PROJECT WILL BE REINTERPRETED UNDER THE 2006 IBC, CHAPTER 10, SECTION 1017. THERE IN TABLE 1017.1, UNDER B OCCUPANCY IN A BUILDING WITH SPRINKLERS, NO FIRE RATING IS REQUIRED FOR THE WALLS, CEILINGS, DOORS, RELITES, ETC. HENCE, MS&A HAS REMOVED ALL REFERENCES TO THOSE PARTICULAR ELEMENTS ON OUR DRAWINGS UNDER REVISION DELTA #3, DATED 10/24/08. THIS DECISION REQUIRES THAT IN LIEU OF THE ONE HOUR CONSTRUCTION, THE EMERGENCY PATHWAY LIGHTING (MEANS OF EGRESS ILLUMINATION) BE UPDATED FOR THE ENTIRE PROJECT PER 2006 IBC, CHAPTER 10, SECTION 1006. NA 9 EVIE tO FOR CODE CM/191.1010E APPROVED OCT 31 2000 ity Of Tukwila BUILDING DIVISION NO. z\ GATEWAY CORPORATE CENTE BUILDING #7 REVISIONS No changes shall be made to the scop of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Marvin Ste REVISIONS /ISSUANCE: PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TUKWILA, WA 98168 planning EGI- TER 'D AR ' HITE T EORG H. re- STATE OF WA i sociates, tic design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 --000 CHECKED BY: GH, GG DATE: 5/6/08 REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE 5/6/08 6/5/08 6/6/08 10/24/08 COVER SHEET & DETAILS TI- OF GATEWAY CORPORATE MATCH EXISTING // ;.y // N / /N / N 8 j r 2T-0" r 21 -0" .Tn ."II n" ^AV 2'-0" 2' -0" 4I I n n. r • n AI " nn mini- . .n. / / A -- j` U A 'ED IfV`1l DI Arc 6 ACT ADJ AFF ALT ALUIVI APPROX BLDG BLKG B/S CAB CLR CLG CL COL CONC CONST CONT CPT CT DIA DIM DN DR DWG EA ELEC ELEV EXIST EXT FD FIN FLR FLUOR FR FT FURN GA GALV GL GWB HC HDWE HM HORIZ HT HVAC IN INCL INSUL INT JT LF l< 1-0 V UNLESS OTHERWISE NOTED NOTES: I. THRESHOLDS AT DOORW ACOUSTICAL CEILING TILE ADJACENT/ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELECTRIC(AL) ELEVATION (VIEW) EXISTING EXTERIOR FLOOR DRAIN FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH/ FURNISHING GAUGE GALVANIZED GLASS /GLAZING GYPSUM WALL BOARD HIGH HOLLOW CORE HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT LINEAL FOOT ABBREVIATIONS B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET (T- TIMER) B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET B/S WALL MOUNTED COMBINATION VOICE /DATA OUTLET B/S WALL MOUNTED DEDICATED VOICE LINE OUTLET B/S WALL MOUNTED JUNCTION BOX NOTE ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) ELECTRICAL LEGEND DOOR NUMBER TYPE OF DOOR A PAIR OF B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN OAK WOOD FRAME B. RELOCATED B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD FRAME. PROVIDE KICKPLATE IF NOT EXISTING. (TOUCH UP TO LIKE NEW CONDITION) C. NEW B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD FRAME (TOUCH UP TO LIKE NEW CONDITION) D. PAIR OF B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR OAK W0o9/\ FRAME WITH RELITE EACH SIDE. E. NEW B/S 3' -0" WIDE X FULL HEIGHT* SOLID CORE OAK WOOD DOOR IN B/S OAK WOOD n FRAME. 9 EXISTING DOOR HARDWARE a. B/S LOCKSETAND CLOSER b. RELOCATED HARDWARE (VERIFY IF HARDWARE NEEDS TO BE RE- KEYED) c. B/S LOCKSER W/ AUTOMATIC CLOSER d. B/S DOUBLE DOOR HARDWARE W/ A AisMATIC SLIDE BOLT wAr 2 T TI T 1 - • 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. i N L \ U / N i WOOD FRAMES EQUAL SECTIONS OF GLASS SEE PLAN FOR OVERALL OD DIMENSIONS * GENERAL CONTRACTOR IS TO CONFIRM HEIGHT OF EXISTING DOORS AND MATCH NEW DOORS TO THAT ©© MAX MECH MFR MIN MISC MTD MTL NA NIC NO. ( #) NOM NTS OC OPNG OPP ORIG P.J. PL PLAM PLYWD PNL PR PTN R RB REF (R) REINF REQ REV RM RO SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP T.B.D. TEL TYP U.C. U.N.O. VCT VERT V.I.F. W/ W/O WC WD WS HAGER KICK PLATE MATCH EXISTING T 11 I DOOR & HARDWARE SCHEDULE MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PANEL JOINT PLATE PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION RADIUS RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TO BE DETERMINED TELEPHONE TYPICAL UNDER CABINET UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WITHOUT WALLCOVERING WOOD WORKSTATION SCHEDULED BASE 3/8" =1' -0" FIRST FLOOR AREA OF WORK 66' EGRESS PATH 3 I EXITING PLAN FINISH FLOOR II li VIII ■1I 8" x' CONT. 3 5/ 25 GA. TRACK W/ � _I MIN M 11Ii l� , N N N TA! 1411V 11I - 1 . LINE OF CEILING GRID --- BEYOND, SEE R.C.P. SUBFLOOR - - NEW CHAIR RAIL a N NEW RELOCATED COMMON PATH OF EGRESS = 75' MAX. 3 5/8" 5" EXISTING TENANT DEMISING PARTITION 121 CONSTRUCTION LEGEND 78' EGRESS PATH SEISMIC BRACING PER 91TI -1 5/8" FIRE TREATED PLYWOOD BLOCKING @ WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: 20" WIDE GALV. SHEET METAL (IN LIEU OF WOOD BLOCKING) 3 5/8" x 25 GA. GALV. STEEL STUD @ 16" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. 5/8" TYPE "X" GWB EACH SIDE PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS. SCHEDULED BASE CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN EMBEDMENT. NOTES: 1. SEAL BOTTOM OF WALL TO FLOOR SLAB USING ACOUSTICAL CAULKING CONTINUOUS BOTH SIDES. 2. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION. NEW CORRIDORS TO BE BUILT TO MATCH. STANDARD TENANT SOUND PARTITION NTS EXISTING BUILDING CORE/COMMON AREAS TO REMAIN UNALTERED EXISTING TENANT INTERIOR SOUND PARTITION: SEE DETAIL 71TI -1. U.N.O. = = = = EXISTING CONSTRUCTION TO BE DEMOLISHED. NEW TENANT INTERIOR SOUND PARTITION: SEE DETAIL 71TI -1. U.N.O. NEW OR RELOCATED B/S RELITE PARTITION TO MATCH EXISTING (SEE PLAN FOR DIM.) (TEMPERED SAFETY GLASS WITHIN 2' -0" OF DOOR JAMB AND LESS THAN 1' -6" SILL HEIGHT A.F.F.) EX -ACOUSTICAL BATT INSULATION ABOVE CEILING TO EXTEND 24" BEYOND EACH SIDE OF WALL LINE OF CEILING GRID BEYOND, SEE R.C.P. SUSPENDED ACOUSTIC TILE CEILING - DO NOT CUT CONT. 'L' METAL TRIM W/ PAPER WING COMMON PATH OF EGRESS = 96' MAX. SECOND FLOOR OFFICE: 6,180 SF / 100 = 62 CLASSROOM: 8,150 SF / 20 = 408 TOTAL OCCUPANCY LOAD = 470 FIRST FLOOR (470 + 157 + 157) 785 X .02 =157" 157 < (36 + 72 + 72) OR 180" : OKAY SECOND FLOOR AREA OF WORK NO CHANGE TO EXISTING SQUARE FOOTAGE ON EITHER FLOOR ACOUSTICAL CEILING SYSTEMS INSTALLATION EXITING & OCCUPANCY INFORMATION FIRST FLOOR OFFICE: 10,199 SF / 100 = 102 CLASSROOM: 6,248 SF / 20 w 312 LIBRARY: 675 SF / 50 = 14 ASSEMBLY: 641 SF / 15 = 43 TOTAL OCCUPANCY LOAD = 471 (2) EXITS REQUIRED (3) PROVIDED EACH FLOOOR SECOND FLOOR 470 / 3 =157 X 0.2 = 32" MIN. WIDTH AT EACH SECOND FLOOR EXIT VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' -0" O.C. OR NO. 10 GAUGE @ 5-0" O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE "PIN ". VERTICAL STRUT STABLING BAR @ 12' -0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. MAIN RUNNER AT 4' -0" O.C. -. VERTICAL STRUT FASTENED TO MAIN RUNNER. CROSS RUNNER INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9. IN ACCORDANCE WITH ASTM C 635 & 6. SUSPENDED CEILING SUPPORT DATA LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS - RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PINS THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SF. FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN, OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 IN. OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE AS REQUIRED BY CURRENT CODES. NORTH FOR INFORMATIONAL PURPOSED ONLY I SUSPENDED CEILING BRACING PA"N II% /III r L _J I I I-----1 EXISTING NON -RATED CEILING GRID AND TILES EXISTING RATED CEILING GRID AND TILES 131 LIGHTING LEGEND EXISTING B/S GYP BOARD CEILING EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE EXISTING 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED 1/32" =1' -0" EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN EXISTING B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO REMAIN NEW OR RELOCATED B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER EXISTING 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO BE REMOVED /RELOCATED EXISTING B/S RECESSED DOWN LIGHT NEW COVENTRY ARCHITECTURAL SERIES P2C PENDANT. AVIATION CABLE/COILED 10' CORD, DL12 CLEAR DOMED ACRYLIC LENS. B/S SWITCH (N =NEW) • B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN) N NEW NTS NTS 1 I VICINITY MAP SITE PLAN (2) #10 SCREWS REVEAL (PAINT BLACK) OR MATCH EXISTING. 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. 141 LIGHTING NOTES NOTES: 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 9 I TYPICAL PARTITION BRACING NO CHANGE TO BUILDING STRUCTURE OR USE METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12' -0 ". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SUSPENDED CEILING. SCHEDULED PARTITION LATERAL BRACING TENANT WALLS (w /o CASEWORK) NTS 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX 2' MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) NORTH NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ABOVE TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (SEE FLOOR PLAN, TI -3) NTS EXISTING SITE DEVELOPMENT TO REMAIN AS IS NTS 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 1- 1/2 " =1-0" 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING OF 1 FT CANDLE @ FLOOR. 3. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. UNDER SEPARATE PERMIT 4. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF VA.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 6. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 7. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 8. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 9. RE- CIRCUIT SWITCHING AS NECESSARY. ALL NEW CLASSROOMS, INCLUDING LABS, TO HAVE DUAL SWITCHES. EACH SWITCH WILL CONTROL 50% OF THE LIGHT FIXTURES IN THESE ROOMS AND BE GROUPED INTO FRONT HALF AND REAR HALF OF ROOM. 5 10 SCOPE OF WORK: TENANT IMPROVEMENT TO PART OF THE FIRST AND SECOND FLOOR FOR ADMINISTRATIVE OFFICE AND TECHNICAL TRAINING USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, OUTLETS AND FINISHES. CONSTRUCTION TYPE: Ill -B, SPRINKLERED FIRST FLOOR AREA OF SUITE: +1- 17,736 SECOND FLOOR AREA OF SUITE: +/- 14,330 OCCUPANCY: B OFFICE BUILDING CODE: WASHINGTON STATE BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 -ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE LEGAL DESCRIPTION 7 GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER TAX ID NUMBER: 271600 -00- 0070 -06 SITE ADDRESS 12720 GATEWAY RIVE TUKWILA, WA 98168 PROJECT DIRECTORY: TENANT: ITT TECHNICAL INSTITUTE 13000 NORTH MERIDIAN ST CARMEL, IN 46032 CONTACT: ADAM MERKLE 317- 706 -9316 (PHONE) 317- 571 -0140 (FAX) DESIGNER: MARVIN STEIN AND ASSOC., LLC 2221 5TH AVE. SEATTLE, WASHINGTON 98121 CONTACT: GALEN HOLDEN 206 -441 -1449 (PHONE) 206- 441 -4361 (FAX) EMAIL - g.holden @marvinstein.com PROJECT INFORMATION 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS FOR THIS PROJECT. 3, CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4, B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD, AS DRAWN OR SPECIFIED IN THE CONTRACT DOCUMENTS. 5. BY L.L. @T.E. INDICATES "BY LANDLORD AT TENANT'S EXPENSE" 6. DIMENSIONS BETWEEN ELECTRICAL & TELEPHONE OUTLETS TO BE A MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 7. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS REQUIRED FOR THIS PROJECT. 8. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS, AS INDICATED HERE AND AS REQUIRED BY LOCAL JURISDICTIONS. 9. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, FIRE ALARM & SECURITY SYSTEM RENOVATIONS SHALL BE PROVIDED UNDER SEPARATE PERMITS. 10. ALL FURNITURE MOVING (INCLUDING SYSTEMS /CUBICLE FURNITURE) SHALL BE PERFORMED BY THE CONTRACTOR. GENERAL CONDITIONS PRICING SHOULD INCLUDE ALL COSTS TO HANDLE FURNITURE. 11. PAINT COSTS SHALL INCLUDE THE REMOVAL OF DRYWALL ANCHORS AND ANY PATCHING /REPAIR WORK FOR APPROXIMATELY 300 MISC. HOLES IN WALLS DUE TO ARTWORK/PROMOTIONAL WALL HANGINGS. 12. CONTRACTOR SHALL CREATE, UPDATE (WEEKLY) AND WORK WITHIN A PUBLISHED CONSTRUCTION SCHEDULE. 13. CONTRACTOR SHALL MAKE A REASONABLE EFFORT TO COMMUNICATE WITH THE DIRECTOR OF THE SCHOOL CONCERNING DAY -TO -DAY CHANGES IN THE WORK SCHEDULE, PARTICULARLY WHEN WORKING IN OCCUPIED SPACES. 14. CONTRACTOR SHALL MAINTAIN A PRACTICE OF DAILY CLEANUP, INCLUDING CONSTRUCTION DEBRIS, TOOLS, EQUIPMENT, AND MACHINERY. EXTRA CARE SHALL BE TAKEN TO CLEAN AROUND CONSTRUCTION DUMPSTERS. DUMPSTERS SHALL NOT SIT DIRECTLY ON ASPHALT OR CONCRETE, NOR SHALL THEY BE PLACED ON SOIL. PLYWOOD SHALL BE USED AS A BARRIER BETWEEN DUMPSTER BEARING POINTS AND HARD SURFACES. 15. NEW MATERIAL SHALL BE STACKED IN A 'NEAT AND ORDERLY' FASHION, AWAY FROM HIGH TRAFFIC AREAS AND OCCUPIED SPACES, 16. IF NECESSARY, CONTRACTOR SHALL PRODUCE AND MAINTAIN ON -SITE STORAGE CONTAINERS. CONSTRUCTION RELATED MATERIAL AND EQUIPMENT SHALL NOT BE STORED IN OCCUPIED ITT SPACES. CORRECTION GENERAL NOTES TI -1 COVER SHEET & DETAILS TI -2 FIRST FLOOR DEMOLITION PLAN TI -2.1 SECOND FLOOR DEMOLITION PLAN TI -3 FIRST FLOOR CONSTRUCTION PLAN TI -3.1 SECOND FLOOR CONSTRUCTION PLAN TI -4 FIRST FLOOR REFLECTED CEILING PLAN TI -4.1 SECOND FLOOR REFLECTED CEILING PLAN TI -5 FIRST FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -5.1 SECOND FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -6 FIRST FLOOR FINISH PLAN TI -6.1 SECOND FLOOR FINISH PLAN TI -7 ELEVATIONS AND DETAILS 15 I DRAWING INDEX BUILDING OWNER: RREEF 16000 CHRISTENSEN RD SUITE 101 TUKWILA, WA 98188 CONTACT: NANCY ANDERSON EMAIL: nancy.anderson @rreef.com CONTRACTOR: T.B.D. Permit Na . Fe O Y Pity review approval Is subject to c and onIssions" Approval of construction document does not authcre the violation of any adopted code or penance. R clipt of approved Feld Copy an conthions is a> ' noiedgcd: 8y �c9 City of Tula 1 REVISION N ... ___ \ PO' RECEIVED CITY OF TUKWILA OCT 247008 PERMIT CENTER THIS PROJECT WAS INITIALLY SUBMITTED FOR PERMIT UNDER 2006 IBC. HOWEVER, MUCH OF THE ORIGINAL CONSTRUCTION WAS DONE UNDER OLDER CODES IN THE '90'S. IN RESPONSE TO EARLY CONVERSATIONS WITH THE CITY OF TUKWILA, THE INTENT WAS TO COMPLY WITH THOSE OLDER CODE CONSTRUCTION REQUIREMENTS WHERE ONE HOUR RATED CORRIDORS, CEILINGS, DOORS, ETC WERE ORIGINALLY CALLED FOR. IN THE FIELD DURING CONSTRUCTION, IT BECAME APPARENT THAT MANY OF THE ONE HOUR COMPONENTS THERE HAD NOT BEEN MAINTAINED WELL OVER THE COURSE OF OCCUPANCY WITH REMODELS, MAINTENANCE, ETC. THEREFORE, AFTER MORE RECENT CONVERSATIONS WITH THE CITY, THE PERMIT FOR THIS PROJECT WILL BE REINTERPRETED UNDER THE 2006 IBC, CHAPTER 10, SECTION 1017. THERE IN TABLE 1017.1, UNDER B OCCUPANCY IN A BUILDING WITH SPRINKLERS, NO FIRE RATING IS REQUIRED FOR THE WALLS, CEILINGS, DOORS, RELITES, ETC. HENCE, MS&A HAS REMOVED ALL REFERENCES TO THOSE PARTICULAR ELEMENTS ON OUR DRAWINGS UNDER REVISION DELTA #3, DATED 10/24/08. THIS DECISION REQUIRES THAT IN LIEU OF THE ONE HOUR CONSTRUCTION, THE EMERGENCY PATHWAY LIGHTING (MEANS OF EGRESS ILLUMINATION) BE UPDATED FOR THE ENTIRE PROJECT PER 2006 IBC, CHAPTER 10, SECTION 1006. NA 9 EVIE tO FOR CODE CM/191.1010E APPROVED OCT 31 2000 ity Of Tukwila BUILDING DIVISION NO. z\ GATEWAY CORPORATE CENTE BUILDING #7 REVISIONS No changes shall be made to the scop of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Marvin Ste REVISIONS /ISSUANCE: PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TUKWILA, WA 98168 planning EGI- TER 'D AR ' HITE T EORG H. re- STATE OF WA i sociates, tic design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 --000 CHECKED BY: GH, GG DATE: 5/6/08 REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE 5/6/08 6/5/08 6/6/08 10/24/08 COVER SHEET & DETAILS TI- OF GATEWAY CORPORATE MATCH EXISTING GATEWAY CORPORATE BUILDING 12720 TUKWILA, Cr-OR GATEWAY STATE CENTER #7 DRIVE WA 98168 ' A CH{ ~ T H rv-s LL 4111: y O WA C INGTOP! 1 Marvin Ste ; :sociates, LLC planning design desi n 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: OH, GG DATE: 5/6/08 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 A\ PERMIT REVISION 6/5/08 0 GENERAL REVISION 6/6/08 A\ PERMIT REVISION 10/24/08 RECEIVED CITY OF TUKWILA OCT 2 4 Z008 RER?vii ( CENTER TENANT: ITT TECHNICAL INSTITUTE SHEET TITLE: FIRST FLOOR DEMOLITION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. 1 1 TI-2 1 OF 12 i • ��T " per ... w InJW .I 1 . 1 1. m rj! 1t :ilr Ill Ilk � LOBBY EXISTING CORRIDOR ORM E ww- T T / I I I ` / \ II `\ � I I 1 + 1 1 F j LEEEE -, _ — FEC = =9 D.F. FEC 0 - -7— — --- _ __i_ ____ — I ,_- 1 _ .. ._ I - --= -� 1 1 I I . v\ — I r T . _ _' — ... r - -h,,,, I 4 I I " 1 \ 1 1 L 1 _I ,,,j_ \ I 1 I• I I 1 1 1 \ I I I I \I I 1 I I I�‘,...' L L 1 J L 1 — 1 1 I I 1 I I I 1 1 (3 1 \ 1 1 I 1 1 _i - - L L. 1 I I I 1 I I 1 I 1 I 1 I 1 I 1 I 1 1 I 1 1 .. 1 1 I I I \ I 1 1 I 1 1 - - - L 1 a I If. C FEC i 6 . 6 -8 " 1/8" = -0" MOLITION NOTES: CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES ING TENANT IMPROVEMENT. ISRUPTION OF BUILDING WATER, ELECTRICAL WER, FIRE ALARM & SECURITY SYSTEMS MUST BE ORDINATED WITH ALL GOVERNING AGENCIES & LDING OWNERIMANAGEMENT. HIS PLAN INDICATES EXISTING CONDITIONS. ALVAGE ALL DOORS, FRAMES, HARDWARE AND RELITES TO BE RELOCATED. SEE CONSTRUCTION PLAN FOR LOCATIONS. DEMOLITION KEYNOTES: O DEMO ROLL -UP DOOR, TRACK AND HARDWARE ABOVE - RETURN TO OWNER 0 DEMO WINDOW AND RETURN TO OWNER DEMO EXISTING CEILING GRID AND TILE THIS ROOM REMOVE EXISTING CHAIR RAIL AND WALL COVERING FIRST FLOOR PLAN NORTH 0 5' 10' 20' 30' NIC NIC C IO, Sup Ir o -a ���. III" 1111h.I . rvl'� iel'I ll s ?:'r1 1 1Al0 , „hi 1 , . , II 1 1 1 f 1 1 1 1 1 1 WOMENS MENS fc1 "rINl1;” V iti" 6tii' �F'i' 1 WOMEN idiIIIV 1 11 11,00 11111T .10311101003.0.0 1 03 1,6 11.101011103 0011 4., M w,. .9r. I s 1- fr klNMhk1V I' IS O I.I�d�1n 1 III !i""O f4'Ilk f .w MAW ;"7I Ec ;y 1 i1 1 1 4 n , 1'II LJ D.F. 1 . 7i/ tru :�0�'1�1&1 1 11011 1 41411 II! O 1I I I uriPa uu 1 1iiilii IIl 111 MINIMS 21110 p,3,1 II 1141111,1 sl fl LOBBY 1/8" =1' -0" 0 5' 10' DEMOLITION NOTES: I. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 3. THIS PLAN INDICATES EXISTING CONDITIONS. 4. SALVAGE ALL DOORS, FRAMES, HARDWARE AND RELITES TO BE RELOCATED. SEE CONSTRUCTION PLAN FOR LOCATIONS. DEMOLITION NOTES: 0 REMOVE VCT AS REQUIRED FOR NEW FLOOR PATH 0 REMOVE CASEWORK AND RETURN TO OWNER OR ITT Q CONTRACTOR TO VERIFY INSIDE OF STRUCTURE - DEMO IF POSSIBLE SECOND FLOOR PLAN NORTH 20' 30' J NIC J NIC NIC NIC lo III rFtS T ,I 444,I' iN l "r]IiuVir�Is rc 11 1 CORPORATE GATEWAY CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 6512 - T;LH .iS i'i. ::0 e STATE OF W. I? 4: Marvin Ste ,i sociates, tic tannin design g n g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS n DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 PERMIT REVISION 6/5/08 6/6/08 // GENERAL REVISION .\ PERMIT REVISION 10/24/08 RECEIVED TUKWILA CIII Y OF OCT 21- 2008 PERMIT CENTER TENANT: ITT TECHNICAL INSTITUTE SHEET TITLE: SECOND FLOOR DEMOLITION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. 1-2. OF 12 ll s ?:'r1 1 1Al0 , „hi 1 , . , II 1 1 1 f 1 1 1 1 1 1 WOMENS MENS fc1 "rINl1;” V iti" 6tii' �F'i' 1 WOMEN idiIIIV 1 11 11,00 11111T .10311101003.0.0 1 03 1,6 11.101011103 0011 4., M w,. .9r. I s 1- fr klNMhk1V I' IS O I.I�d�1n 1 III !i""O f4'Ilk f .w MAW ;"7I Ec ;y 1 i1 1 1 4 n , 1'II LJ D.F. 1 . 7i/ tru :�0�'1�1&1 1 11011 1 41411 II! O 1I I I uriPa uu 1 1iiilii IIl 111 MINIMS 21110 p,3,1 II 1141111,1 sl fl LOBBY 1/8" =1' -0" 0 5' 10' DEMOLITION NOTES: I. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 3. THIS PLAN INDICATES EXISTING CONDITIONS. 4. SALVAGE ALL DOORS, FRAMES, HARDWARE AND RELITES TO BE RELOCATED. SEE CONSTRUCTION PLAN FOR LOCATIONS. DEMOLITION NOTES: 0 REMOVE VCT AS REQUIRED FOR NEW FLOOR PATH 0 REMOVE CASEWORK AND RETURN TO OWNER OR ITT Q CONTRACTOR TO VERIFY INSIDE OF STRUCTURE - DEMO IF POSSIBLE SECOND FLOOR PLAN NORTH 20' 30' J NIC J NIC NIC NIC lo III rFtS T ,I 444,I' iN l "r]IiuVir�Is rc 11 EET LAB 113 NEW OFFICE 112 MUL. /PTN. NEW LIBRARY 111 INTERVIEW 110 NEW FM OFFICE 109 NEW OFFICE 108 MUL. /PTN. NEW INTERVIEW 107 NEW INTERVIEW 106 INTERVIEW 1 1051 OFFICE 104 • 1' -0" EQ. HALL 138 107 B O NEW CAREER SERVICES 102 B b 101 B b 142 118 EQ. EXTEND WALLS TO STRUCTURE ABOVE THROUGHOUT ENTIRE ROOM. HALL 141 STORAGE 130 SECRETARY 103 3 7 INTERNET CAFE 137 BOOKKEEPER 134 (1 — STORAGE 131 135 INTERVIEW COPY ROOM 129 I 128 INTERVIEW ' L STAFF LOUNGE F EC9 O a 114 REGISTRAR 133 TESTING 132 mi INTERVIEW 102 139 u LJ D.F. FEC . HALL BOOKSTORE 136 ALIGN @ CORNER I I 127 C) VERIFY FHC NEW THEORY 1 117 HALL 140 O Q 7'-0" 0 J ANITOR 121 FECII E) WOMENS 1 120 O _r NEW CJ LAB 115 --••■• STORAGE 122 THEORY 0 ik r LAB LAB 124 REPS CALL CENTER 125 I LOBBY EXISTING ONE HOUR RATED 0 /\o CONSTRUCTION NOTES: 1. CLEAN AND REPAIR BLINDS IN NEW CLASSROOMS AND OFFICES AS REQUIRED. 2. CONTRACTOR TO PROVIDE BACKING IN WALLS AT ALL WHITE BOARD AND CASEWORK LOCATIONS. 3. MAINTAIN EXISTING CORRIDOR AND CEILING CONSTRUCTION. 4. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 5. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 6. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 7. SEE 12/1 -1 FOR WALL CONSTRUCTION LEGEND. 8. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION. NEW CORRIDORS TO BE BUILT TO MATCH. CONSTRUCTION KEYNOTES: O CONTRACTOR TO PROVIDE AND INSTALL POLYVISION 100 SERIES 4' X8' M1140 -084 WHITE BOARDS WITH NARROW PROFILE EXTRUDED ALUMINUM TRIM PEN /MARKER TRAY WITH RADIUS SAFETY CORNERS. VERIFY LOCATION WITH TENANT. Q CONTRACTOR TO PROVIDE 1" X 6" WIDE SOLID POPULAR (PAINT GRADE) CHAIR RAIL WITH ROUNDED CORNERS. WOOD TO BE MOUNTED WITH SCREWS, PLUGGED AT SCREW HOLE, AND SANDED SMOOTH. INSTALL AT 34" TO THE TOP WHERE INDICATED. REPAIR / REPLACE WHERE NEEDED. SEE FINISH SCHEDULE FOR PAINT 0 EXTEND WALLS TO STRUCTURE ABOVE THROUGHOUT ENTIRE ROOM. CONTRACTOR TO INCLUDE COST FOR FRAMING, SHEET ROCK AND FINISHING - ACHIEVING A SMOOTH WALL LOOK. Ir r C KL - TH • r 01 TE' ' C' 1 S ' u I IRED. REMOVED PORTION OF EXISTING CHAIR RAIL. PATCH AND REPAIR WALL. 6 NEW PARTIAL HEIGHT RELITE 3' -0" HIGH X 4' -0" WIDE WITH TOP AT 7' -0" A.F.F. FIRST FLOOR PLAN NORTH 1/8 -1' -0" 5' 10' 20' 30' N.I.C. EXISTING RATED CORRIDOR N.I.C. NTS STRUCTURE ABOVE. EXTEND EXISTING PARTITION TO STRUCTURE ABOVE EXISTIND PARITION FROM FLOOR TO UNDERSIDE OF HUNG CEILING TO REMAIN Cry lll�lllllllN ' .' MUUMUU 518" GWB, TYPE 'X' EACH SIDE, TYP. CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO EXISTING TRACK LINE OF CEILING GRID BEYOND, SEE R.C.P. SUSPENDED ACOUSTIC TILE CEILING TO BE CUT XTENDED TENANT PARTITION TO STRUCTURE A MAW WE n. NO. A A A\ GATEWAY CORPORATE CENTER BUILDING #7 Marvin Ste planning REVISIONS /ISSUANCE: PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TUKWILA, WA 98168 A G= •RGEH. r • . _LID II TATE'OF WAS •INGTON REVISIONS INDICATED THUS A sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028-000 CHECKED BY: GH, GG DATE: 5/6/08 ISSUED FOR PERMIT AND APPROVAL CITY OF ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE 5/6/08 6/5/08 6/6/08 1 0/24/08 V UKWILA OCT 2 4 2008 PFRM!T ENTER FIRST FLOOR CONSTRUCTION PLAN TI OF GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 9 816 8 65 R. 1ST "REv rt ARCH' E T E . GE 1. COOD J.L ° € TATE OF WA ' TON Marvin Ste : :sociates, tic tannin design � n g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 I CHECKED BY: GH, GG DATE: 5/6/08 SCALE: AS NOTED I REVISIONS /ISSUANCE: I NO. REVISIONS INDICATED THUS A DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 A PERMIT REVISION 6/5/08 6/6/08 A GENERAL REVISION PERMIT REVISION 10/24/08 RECEIVED OF TUKWILA CITY OC 2 4 7005 PERMIT CENTER TENANT: ITT TECHNICAL INSTITUTE SHEET TITLE: SECOND FLOOR CONSTRUCTION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. 1-3. OF 12 I o N J J 1 m co co ▪ NN cp Q ^ I (-4 (f) N E • Q i v o. ƒ� o ff- U >< E r IAI..I.11J:i�y, � ,"7' ly 777 ' II lay?, , r " II '�,�,, ,,��,�'. gVf.�'�tlukf�IT�e.�i. J� �����'S� li",IP 1, 51 ����.i�. ! I � f<�41.fi.�:l Iw a -��A I�I ,...F STUDY GROUP STUDY GROUP r Iu'I �tiil. WOMENS 00111011i gig MI IN „ 'imamdr4o 4 ni Iya I I I III IIIw "I� : ,VIII I[ �1 y�ll l Iti� � ✓�� e ,.. � � w d�i " �' �Ti�' �Il�, u;"I.'.u1 EXISTING CORRIDOR MINN WON min SAN WM OIROMM lIuz° t li!' I'II�' 1 ��3Ill)I I i I THEORY STUDY GROUP 203 LAB 209 EQUIPMENT ROOM 210 THEORY 211 CO N HALL 225 I THEORY 206 223 INTERVIEW D.F. STORAGE 221 D011. I FEC FEC CLOSET 22 FHC HALL 224 •FE NEW OFFICE 217 (N) T NEW OFFICE _ I IE EE co U 20' -2” I 212 I 01 INSTRUCTORS OFFICE AREA �a'ri1 iiineNtlic [ zoo_ I E NEW THEORY 216 EET LAB EET LAB 214 NEW COMPUTER LAB 1/8" =1' -0" CONSTRUCTION NOTES: 1. CLEAN AND REPAIR BLINDS IN NEW CLASSROOMS AND OFFICES AS REQUIRED. 2. CONTRACTOR TO PROVIDE BACKING IN WALLS AT ALL WHITE BOARD AND CASEWORK LOCATIONS. 3. MAINTAIN EXISTING CORRIDOR AND CEILING CONSTRUCTION. ,r 4. AL ALL ' LS + ' IG EACH SIDE. 5. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 6. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. A 8. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION. NEW CORRIDORS TO BE BUILT TO MATCH. CONSTRUCTION KEYNOTES: Q CONTRACTOR TO PROVIDE AND INSTALL POLYVISION 100 SERIES 4' X8' M1140 -084 WHITE BOARDS WITH NARROW PROFILE EXTRUDED ALUMINUM TRIM PEN /MARKER TRAY WITH RADIUS SAFETY CORNERS. VERIFY LOCATION WITH TENANT. O CONTRACTOR TO PROVIDE 1" X 6" WIDE SOLID POPULAR (PAINT GRADE) CHAIR RAIL WITH ROUNDED CORNERS. WOOD TO BE MOUNTED WITH SCREWS, PLUGGED AT SCREW HOLE, AND SANDED SMOOTH. INSTALL AT 34" TO THE TOP WHERE INDICATED. REPAIR / REPLACE WHERE NEEDED. SEE FINISH PLAN FOR PAINT COLORS. SECOND FLOOR PLAN NORTH 0 5' 10' 20' 30' r1.rLrL.• FO LL ST ION EN MET ITH • AC UR £ SON I N.I.C. J co co , : ONO �1 H- C l C C-: H- c2 E "•rrr T. -._ - - ., Vii;: i��irrurwa�_p® _ IMMO ■WMI �■ M M AI 111 °ft=0 1 1 IMMEMIIMEIMMI WIEFAMAMAIIIIMM MI / FIEIMIni., =.....— Imp® miimmrmmim =miss IIIIIMPIM :�IIIIN r i C. iii III ■mo ■III■®I aii = I ■iiiM 6 ' ■'ii�IOrI / ■ ■ II / ■I■ ■■■■ / ■ I ® / ril / ,, *■mg=m= i■ml i ■�■i ■�■ / �� ■ ■1c= ■ I■I■i ; " ��ra I I m ■® ■■■ I ■rm _ MINIM i ■mime I 1 i ! i r ■■ 1 / 11 EM■ ill mow III■■ . ilio lma I ■■ ■ 1 ME IM EN MEN! I■ ■[OLI EMI I ■ � ■111■ ■4 �I� 1 I■ I ■■ li ■ ■ ■ri■i il ■IIMOrm _1 ■u. ■111■ III ■ ■ M_II ■ =11M11111 1 128 �`!1 �!!■ ■II ■ ■ ■ ■!II `ii = ■II ■ ■ ■ ■I1 ■1i■ ■ ■— .I : M\U I I_ fir1� �� 1 l rrrr ��� , ■■ _ 11111E- r � _ \1T1/ "-I1031IL11 I II II ■ 1l■■■ II■■'■i• IMIMEm ■ -I / ■■■■ ■ ■I MENIME■■MEMEM® 11— � M M iiI ■iiniII�Ii a Imo ■ ■■ ■■ ■■ ■ ■_ i. JJI. ii= mg= ,I ■ ERN ■ ■ ■i!■ ■11 ■ ■III 1.1111EASE I�■1111■ ■ r: � 1�■:I •`■■ ill■■iiu iIII� ■ ■ ■ ■ IJ1■i � ICI► 1 ■II■liM 131 ■II■ ®■O ■ ■I� ■II ■ ■iM ■ ■ ■11 ■ ■I■!!�1� ■� iii I::::■ ■11111= E ■■ EN I ■■ I'::' @;■riiiii _� I rrr. IMIIMITI-TAIIM =:� ■1171 ■i il\II ■■ MI MIIIIIIMIMMMO ■■■■■n 111111■11 ■ ■1• ■11 MIME EMI ■IIIIIC■ ■II!' 1 ■111=1. EXISTING SUSPENDED CEILING SYSTEM ALTERATIONS TO PANEL AND LIGHTING FIXTURES PER CEILING SYSTEMS MANUFACTURES REQUIREMENTS 5, "g5 I�riilLi: ('� llplill''(' 104 100 1 n ( 1FIRST FLOOR PLAN NORTH 1/8" =1' -0" 0 5' 10' EXISTING LAYOUT: PROPOSED LAYOUT: LIGHTING CALCULATIONS: (226) 2X4 RECESSED FLOURESCENT FXTURES (3) 2X2 RECESSED FLOURESCENT FXTURES (10) 1X4 RECESSED FLOURESCENT FIXTURES (17) RECESSED FLOURECSENT DOWN LIGHT TOTAL = 22,554 WATTS (223) 2X4 RECESSED FLOURESCENT FXTURES (3) 2X2 RECESSED FLOURESCENT FXTURES (9) 1X4 RECESSED FLOURESCENT FIXTURES (17) RECESSED FLOURECSENT DOWN LIGHT (8) SUSPENDED PENDANT FIXTURE TOTAL = 22,472 WATTS SUMMARY: THE EXISTING LAYOUT HAS A TOTAL OF (22,554) WATTS. THE PROPOSED LAYOUT HAS A TOTAL OF (22,472) WATTS. NO WATTAGE IS ADDED: OKAY REFLECTED CEILING NOTES: 1. SEE 14(TI -1 FOR LIGHTING NOTES 2. SEE 87I -1 FOR SUSPENDED CEILING BRACING 3. ADJUST EXISTING ACOUSTICAL TILE CEILING AS SHOWN 4. THE EMERGENCY PATHWAY LIGHTING THAT EXISTS MUST BE MAINTAINED PER CODE, NEW AREAS OF WORK MUST ALSO COMPLY, & THE ACTUAL EMERGENCY PATHWAY LIGHTING LOCATIONS NEED TO BE DEPICTED ON THE ELECTRICAL ENGINEERS PLANS. 5. PATCH AND REPAIR GRID AND TILE TO LIKE NEW CONDITION REFLECTED CEILING KEYNOTES: O DEMO EXISTING CEILING GRID AND TILE THIS ROOM. RE- CIRCUIT SWITCHES TO ACCOMMODATE NEW LIGHTING LAYOUT. PROVIDE OUTLET AND DATA JACK FOR FLAT SCREEN IN CEILING. SEE ELECTRICAL PLAN ON TI -5 FOR FURTHER DETAIL 20' 30' NO. 0 Q A GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 Marvin Ste planning 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GC REVISIONS /ISSUANCE: GI REVISIONS INDICATED THUS A PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: LL Ill ISSUED FOR PERMIT AND APPROVAL FM H. GOO STATE OF WA tINGTON REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. ITT TECHNICAL INSTITUTE sociates, LLC design DATE: 5/6/08 SCALE: AS NOTED REC EIVED CITY OF TU OCT DATE 5/6/08 6/5/08 6/6/08 10/24/08 4 2008 PERMIT CFMTFR FIRST FLOOR REFLECTED CEILING PLAN TI -4 OF 12 I CORPORATE GATEWAY CENTE' BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 I % E RGE . "..,0 i `LIA V T ATc OF WA Na 'Na3 f F t --tea Marvin Ste .k .sociates, tic tannin design planning n g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 A. PERMIT REVISION 6/5/08 n GENERAL REVISION 6/6/08 A\ PERMIT REVISION 10/24/08 RFCE vED TUKW ILA CITY OF OCT 2 4 2008 PERM!T CE TER TENANT: ITT TECHNICAL INSTITUTE SHEET TITLE: SECOND FLOOR REFLECTED CEILING PLAN REPRODUCTION, ALTERATION OR PUBLICA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. 1-4 OF 1 U In L.) rz c.) OC z W 0 w CC CO 0 N H- U 0 0 (S _.2 � I (D a co cp J N m E I o I II �� o� c H- c.n x N 202 I 203 f. - 207 209 210 211 IN MMMMMMMMMMMMM A1'i4 BO 74 ^'IF iii '. EE■■■ n , ! EE H �Ifi si l���I � Iry i a^� ,�� E■ ii� =PII�dNhi9lhP�N�IIR,��I�l"wrb'r II Ir 110 i aIAy4,' 5IIrW:R E.' 11 ,41 VIII anhatiuydWI LPL My N w nm , t,G. 1.1 • 1 1 1 i Lr IIIMI MI IN MN MN II MI I MI ■ r IN NN I�WV1 4.1,41 I �111 -EMI III11∎∎ 1 �I 717,51 ;,N ■■■ 'IEE I I ._ Ell 11 ■III ■I■IIN U..:I I ■ ■.. ■!EIwa .■...�1i AN r ■■■■I�■ ■�l ■n ...■ � - . iii �____i�r..r� � ■ him minswilM ■ Mil IIIIIIIMM! Mil � � �m ��� ■ — li MI MIll um MIMI� II�I�� - II - II-- 223 -- Il 1 201 I 217 Tali' II/ Iliil ►;r=#1 Mffell «■ MI Ell I•11 INN r ............... ■ MN II r 1 I I 41r4I.I1 .1. ICI ■1 ■I r -I ■I ■1 ■1 ■I In _ ■II ■I 111NIMINNI ■I —■ i -Li I I I ---- a:A TI ■ y ea 1 l'�R��� Ji �' MI •r ilOr 1 2121 I --- NM r - -- 1 1 I 1 1 ■1 U1 ■I ■I -: LOBBY 216 215 1 214 213 P r rt 1/8" =1' -0" EXISTING LAYOUT: PROPOSED LAYOUT: I "1 LIGHTING CALCULATIONS: (221) 2X4 RECESSED FLOURESCENT FXTURES (6) 1X4 RECESSED FLOURESCENT FIXTURES TOTAL = 21,408 WATTS (215) 2X4 RECESSED FLOURESCENT FXTURES (11) 1X4 RECESSED FLOURESCENT FIXTURES TOTAL = 20,992 WATTS SUMMARY: THE EXISTING LAYOUT HAS A TOTAL OF (21,408) WATTS. THE PROPOSED LAYOUT HAS A TOTAL OF (20,992) WATTS. NO WATTAGE IS ADDED: OKAY REFLECTED CEILING NOTES: 1. SEE 14/TI -1 FOR LIGHTING NOTES 2. SEE 81TI -1 FOR SUSPENDED CEILING BRACING 3. ADJUST EXISTING ACOUSTICAL TILE CEILING AS SHOWN 4. THE EMERGENCY PATHWAY LIGHTING THAT EXISTS MUST BE MAINTAINED PER CODE, NEW AREAS OF WORK MUST ALSO COMPLY, & THE ACTUAL EMERGENCY PATHWAY LIGHTING LOCATIONS NEED TO BE DEPICTED ON THE ELECTRICAL ENGINEERS PLANS. 5. PATCH AND REPAIR GRID AND TILE TO LIKE NEW CONDITION LIGHTING KEYNOTES: 0 RE- CIRCUIT SWITCHES TO ACCOMIDATE NEW LIGHTING LAYOUT. SECOND FLOOR PLAN NORTH 0 5' 10' 20' 30' I TAIREn, d1I L �r'tll'i is : WV II )II I f ll:, r ! Gt llIM CO. colvt..ipAce OR AV N (ft ; NN q► Ip • op n► r r Ir��l(II, D.F. FEC OAM 466 Varla el MARAt &. , Marna gig I DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION TENANT: ITT TECHNICAL INSTITUTE SCALE: AS NOTED DATE 5/6/08 6/5/08 GENERAL REVISION 6/6/08 PERMIT REVISION 10/24/08 RECEIVED -.QTY OFM MAMA OCT 2 T ZLJUU PERiiiii iT CENTER 113 � I�e D.F. 116 0 1/8" - LOBBY ELECTRICAL NOTES: ELECTRICAL KEYNOTES: 1. EXISTING ELECTRICAL NOT SHOWN 2. SEE 11/TI -1 FOR ELECTRICAL I COMMUNICATIONS LEGEND 3. SEE 1 -TM FOR LIGHT SWITCHES O CONTRACTOR TO PROVIDE (1) ELECTRICAL OUTLET 7" BELOW THE CEILING AND CENTERED OVER WHITE BOARDS TO ACCOMMODATE (1) CLOCK - MODEL: GRAINGER #5H352, 9" ROUND. PROVIDE OUTLET AND DATA JACK FOR FLAT SCREEN IN CEILING 1' -0" AWAY FROM WALL. FIRST FLOOR PLAN NORTH 0 5' 10' 20' 30' L CO WO \ 10� COO GATEWAY CORPORATE CENTE BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 65 2 Marvin Ste planning STATE G. dal, `, ^ )IO sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 SHEET TITLE: FIRST FLOOR ELECTRICAL / COMMUNICATIONS PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. TI -5 OF 12 GATEWAY CORPORATE BUILDING 12720 TUKWILA, L C GATEWAY DRIVE WA 98168 AGE H. GOOOrEILO" III i N S T A T E OF WASHINGTON • E LATER #7 Marvin Ste �.:sociates, LLc tannin design g n g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 SCALE: AS NOTED REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 PERMIT REVISION 6/5/08 0 GENERAL REVISION 6/6/08 Q3 PERMIT REVISION 10/24/08 RECEI J CITY OF TUK OCT 24Mid PERMIT C .dd EN ENTER Ltd TENANT: ITT TECHNICAL INSTITUTE SHEET TITLE: SECOND FLOOR ELECTRICAL / COMMUNICATIONS PLAN c c c C REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. ( TI-5 c E OF 12 (1111 , il, Illli 4,rll ,''', Nib &ridaiDii vka1f toe ,41,111 wll WEIDE 4'at: :rr �.hll ;�'AWf {tip 4 6101Elih DEED `.D Inl1. QED : tia END t.', .' ,D,ED4 SHIRR 'N. d 4 .,4 : ^.:: LOBBY Ito a� m{ +I d a l { ro V���iFU1N O�� �n�'I,' Itu 4 WAWIEWIPAMMWAMMI 44 ' kd1 9 n 1 Ilfl °1 rflw lall I� w l� �I I hl I � tl 1 Vl�l�l I� I I II2I0� , 011d 4' 1 d 111 IIdr + %iDailm '. I 207 X211 0 5' 10' ELECTRICAL NOTES: 1. EXISTING ELECTRICAL NOT SHOWN 2. SEE 11M-1 FOR ELECTRICAL / COMMUNICATIONS LEGEND 3. SEE 1 —TM FOR LIGHT SWITCHES ELECTRICAL KEYNOTES: O CONTRACTOR TO PROVIDE (1) ELECTRICAL OUTLET 7” BELOW THE CEILING AND CENTERED OVER WHITE BOARDS TO ACCOMMODATE (1) CLOCK— MODEL: GRAINGER #5H352, 9" ROUND. SECOND FLOOR PLAN NORTH 1/8" =1' -0" 20' 30' col yecot hytOce\ o sogett to 50-- LOBBY OMER y9'IIr!i�iin"Iru�oJl�i'. la Imi�ll' Ii��''' i�ro','i�tit'•; 10 i4g FINISH NOTES: FIRST FLOOR PLAN NORTH 1. ALL FINISHES ARE TO BE REPLACED WITH NEW UNLESS NOTED OTHERWISE 2. ALL WALLS TO RECEIVE 3. ALL ROOMS TO RECEIVE 4. BASE 5. ALL CHARI RAILS TO RECEIVE TO BE USED THROUGHOUT UNLESS NOTED OTHERWISE. UNLESS NOTED OTHERWISE. UNLESS NOTED OTHERWISE 6. PROVIDE FINISH SUBMITTALS FOR VERIFICATION THAT MATERIALS ARE STILL IN PRODUCTION AND THAT THEY MATCH EXISTING. FINISH KEYNOTES: O ALL MATERIAL ON DECK TO BE PAINTED P -3 INCLUDING ELECTRICAL, DUCTWORK, SPRINKLER PIPES, ETC. 0 SEE ELEVATION 5/TI -7 FOR EXACT LOCATION O FLOORING, PAINT, AND BASE ARE EXISTING TO REMAIN THIS ROOM O ALL EXISTING WALL COVER IN STUDENT CORRIDOR IS TO REMAIN. PATCH AS REQUIRED. ONLY PROVIDE NEW WALL COVERING ON NEW PARTITIONS. FLOORING LEGEND ❑ VCT 1NCT -5 (SEE PLAN) VCT -2 VCT 3 /i, VCT-4 l=l VCT -6 ROOM BY ROOM FINISH SCHEDULE First Floor Second Floor Flooring 202 Splash 203 Splash 204 Splash 205,Splash 206 S plas h 207LSplash 208 Splash 209,Splash 210 211 Splash 212 Splash 213 Splash 214 215 216 Splash _ 217 2181Splash 219 220 223 Splash 221 - 222 - - 100 Splash Carpet - Cityline 101 Splash Carpet Subtle Sage Cityline 102 Splash Carpet Subtle Sage 'Cityline 103 Splash Carpet Subtle Sage Cityline 104'Splash Carpet Subtle Sage Cityline 105 Splash Carpet Subtle Sage Cityline 106'Splash Carpet Subtle Sage - 107Splash Carpet Subtle Sage Cityline 108 Splash Carpet Subtle Sage Cityline 109,Splash Carpet ,Subtle Sage Cityline 110 Carpet Subtle Sage .Cityline 111 Splash Carpet Subtle Sage Cityline 112,Splash Carpet Subtle Sage Cityline 113' - Subtle Sage Black Tie 114 - Subtle Sage Cityline 115 V Subtle Sage Black CT - 5 S _ Tie 116:Splash Carpet ',Subtle Sage ICit yline 1171Splash Carpet :Subtle Sage Cityline_ 118 ',Splash Carpet ;Subtle Sage Cityline 119, - - 120 - 121' - - - 122' - - 123,Spiash Carpet !Subtle Sage Cityline 124plash Carpet !Subtle Sage Cityline Carpet Subtle Sage Cityline 126;Splash Carpet Subtle Sage _Cityline 127;Splash Carpet ',Subtle Sage Cityline 128;Splash C Subtle Sage Cityline 1 129 Splash Carpet ; Subtle Sage Cityline 130 - - - 1311 Splash Carpet :Subtle Sage Cityline 1321Splash Carpet Subtle Sage Cityline 133 Splash Carpet Subtle Sage vCityline 134{Splash Carpet Subtle Sage 'Cityline 1351Splash Carpet Subtle Sage ;Cityline _ 1361Splash Carpet ;Subtle S age TCityline Subtle Sage, C. Gray, Yarrow, 137' VCT- 1,2,3,4 Black lCityline Admin Corridors 'Splash Carpet Subtle Sage lCityline Student Corridors ; - Subtle Sage Cityline V 201' - - Carpet ,Subtle Sage !Cityline Carpet Subtle Sage Cityline Carpet :Subtle Sage ;Cityline _ Carpet 'Subtle Sage lCityline Carpet Subtle Sage 1Cityline Carpet Subtle Sage lCityline Carpet Subtle Sage 'Cityline Carpet Subtle Sage jCityline I Carpet - Subtle Sage 'C Carpet Subtle Sage lCityline j Carpet Subtle Sage ;Cityline Carpet Subtle Sage Cityline Subtle Sage Black Tie I - Subtle Sage !Black Tie Carpet Subtle Sage j ityline Carpet Subtle Sage Cityline I Carpet Subtle Sage ICit line._.,_ _........ . T _ 2DLC 09 ;Olivine Olivine 2DLC 20 (Patch only - new walls) :Olivine Carpet 'Subtle Sage !Cityline _ T I - Subtle Sage ( lCityline 2DLC 20 (Patch onl y - new walls) Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Jet Black Olivine Jet Black Olivine Olivine Olivine FOlivine i t - Olivine !Olivine _ I Olivine Olivine Olivine ;Olivine Olivine ;Olivine ;Olivine !Olivine Olivine ;Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine Olivine rt Olivine Olivine Olivine 'Jet Black LJet Bl Olivine � �Olivine - rOlivine Olivine -. - Olivine ........, T imm • • ....... MEMO MUM WAIN MIMI II IIIIMMIO MIMEO i Hill O MIME. 1 II II 1 l I iiiii OEM 1 illimmillimmil 'Hta 11 i 111111111111111111111111 FINISH SCHEDULE SYMBOL/NO. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL SIZE CONTACT NOTES CPT -1 GENERAL CARPET PATCRAFT SPLASH 10060 60605 SWAN DIVE NA NA BILL COTHRAN 1-800-713-6697 GLUE DOWN EXT. 5225 FOR NATIONAL ACCT. INFO VCT 1 VINYL COMPOSITION A STONE TEX 52143 NA 12" X 12" SCOTT MAHER 1- 800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT 2 VINYL COMPOSITION ARMSTRONG STONE TEX 52139 NA 12" X 12" SCOTT MAHER 1- 800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT 3 ( VINYL COMPOSITION ARMSTRONG STONE TEX 52155 NA 12" X 12" SCOTT MAHER 1 -800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT-4 VINYL COMPOSITION ARMSTRONG STONE TEX 52153 NA 12" X 12" SCOTT MAHER 1- 800 - 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT 5 VINYL COMPOSITION ARMSTRONG STONE TEX 52127 NA 12" X 12" SCOTT MAHER 1 -800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT 6 VINYL COMPOSITION ARMSTRONG STONE TEX 52144 NA 12" X 12" SCOTT MAHER 1 -800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO SPEEDHIDE INTERIOR MIKE MANETTA 317 - 870 -0351 GENERAL PAINT PITTSBURG PAINT EGGSHELL #1165 ITT SUBTLE SAGE NA NA EXT. 611 FOR NATIONAL ACCT. INFO NA CHAIR RAIL PAINT PITTSBURG PAINT PURE PERFORMANCE #1159 ITT CITYLINE NA NA MIKE MANETTA 317-870-0351 ALL AREA EXCEPT CJ LAB INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL PAINT / PURE PERFORMANCE MIKE MANETTA 317 -870 -0351 CEILING PAINT PITTSBURG PAINT INTERIOR SEMI -GLOSS #11007 ITT BLACK TIE NA NA EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL IN CJ LAB WHITE BOARD TRIM PITTSBURG PAINT PURE PERFORMANCE #1217 ITT BLUE BLAZER NA 12" WIDE BOARDER MIKE MANETTA 317-870-0351 NA PAINT INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO SPEEDHIDE INTERIOR #6165 ITT CONNECTED MIKE MANETTA 317 -870 -0351 ACCENT PAINT PITTSBURG PAINT EGGSHELL GREY NA NA EXT. 611 FOR NATIONAL ACCT. INFO NA 0 ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR #212 6 ITT YARROW NA NA MIKE MANETTA 317 - 870 -0351 NA EGGSHELL EXT. 611 FOR NATIONAL ACCT. INFO RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1158 ITT OYSTER NA NA MIKE MANETTA 317 - 870 -0351 NA INTERIOR SEMI -GLOSS WHITE/ SATIN FINISH EXT. 611 FOR NATIONAL ACCT. INFO RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1900 ITT LIMINOUS NA NA MIKE MANETTA 317 - 870 -0351 NA INTERIOR SEMI -GLOSS WHITE/ FLAT FINISH EXT. 611 FOR NATIONAL ACCT. INFO WALL COVERING D. L . COUCH 2DLC20 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 -433 -0790 WALLS BELOW CHAIR RAIL IN FOR NATIONAL ACCT. INFO STUDENT CORRIDOR 3 WALL COVERING D. L . COUCH 2DLCO9 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 - 433 -0790 LOBBY WALLS FOR NATIONAL ACCT. INFO RUBBER BASE ARMSTRONG NA 06 OLIVINE NA 4" NA ALL AREA EXCEPT CJ LAB B -2 RUBBER BASE ARMSTRONG NA 60 JET BLACK NA 4" NA CJ LAB 0 SOLID SURFACING CORIAN PRAIRIE (E) NA NA NA NA NA PL -1 PLASTIC LAMINATE WILSONART D478 -60 AMAZON NA NA NA NA NO. REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL TENANT: ITT TECHNICAL INSTITUTE f GATEWAY CORPORATE CENTER BUILDING #7 SHEET TITLE: 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning REVISIONS /ISSUANCE: PERMIT REVISION GENERAL REVISION PERMIT REVISION RGE H' 03017FILOW ? STATE OF WA:- .1! CHECKED BY: GI-I. GG 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 FIRST FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, 15 A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design DATE: 5/6108 SCALE: AS NOTED DATE 5/6/08 6/5/08 6/6/08 10/24/08 (1(+T i 11. r TI -6 OF 12 up 0 ci cn c.� z CC J CO N U 6 U CV I1- CD -J N O I N rn Q Ed U d I NII�� o : a i 2' � E • 1 T.. - 225 t ._ - _ . L .. t 4 ..1 =.4; I' J iI e+ l? e is ' III i tgrILI i . , iVY •u "l^ ,� 1 dh� •+"Pso II"a�M�''C�lke LOBBY 1/8" =1' -0" FINISH NOTES: 1. ALL FINISHES ARE TO BE REPLACED WITH NEW UNLESS NOTED OTHERWISE 2. ALL WALLS TO RECEIVE 3. ALL ROOMS TO RECEIVE 4. BASE B -1 TO BE USED THROUGHOUT UNLESS NOTED OTHERWISE. 5. ALL CHART RAILS TO RECEIVE UNLESS NOTED OTHERWISE 6. PROVIDE FINISH SUBMITTALS FOR VERIFICATION THAT MATERIALS ARE STILL IN PRODUCTION AND THAT THEY MATCH EXISTING. CPT -1 SECOND FLOOR PLAN NORTH lti>i'I' ANIR Ililll'iin�t�`�i mliahllW�lliliu. iBlill :V'�MIIIII' w�itrtGi'tt9 Praii'il�t USN UNLESS NOTED OTHERWISE. FINISH KEYNOTES: O PAINT WALL WHERE REQUIRED IN ADJACENT SUITE 0 PAINT TO MATCH EXISTING LOBBY FINISH ® FLOORING, PAINT, AND BASE ARE EXISTING TO REMAIN THIS ROOM Q ALL EXISTING WALL COVER IN STUDENT CORRIDOR IS TO REMAIN. PATCH AS REQUIRED. ONLY PROVIDE NEW WALL COVERING ON NEW PARTITIONS. FLOORING LEGEND ❑ VCT- 1NCT -5 (SEE PLAN) • VCT -2 VCT -3 ✓ VCT-4 ! VCT -6 First Floor ROOM BY ROOM FINISH SCHEDULE Flooring Wall Paint Trim Paint ;Vinyl Wall Covering Base 100 Splash Carpet - ,Cityline 2DLC 09 101 Splash Carpet Subtle Sage ;Cityline ' - 102 . Splash Carpet Subtle Sage ;Cityline - 103 :Splash Carpet Subtle Sage ;Cityline - 104 Splash Carpet .Subtle Sage jCityline - 105 :Splash Carpet . Subtle Sage ;Cityline - 106 ;Splash Carpet 'Subtle Sage - 107 ,Splash Carpet ! Subtle Sage Cityline - 108 . Splash Carpet - et t . Subtle Sage Cityline ' - - - - - - - - . ... ......__ .... . .... ..... 109!Splash Carpet Subtle Sage Cityline - 110 !Splash Carpet ; Subtle Sage Cityline - .111 ;Splash Carpet 'Subtle Sage {Cityline - 112 ;Splash Carpet Subtle Sage !Cityline - 113, - :Subtle Sage ;Black Tie - 114; - ; Subtle Sage jCityline i - 115'VCT- 5 .Subtle Sage !Black Tie - 116 Splash Carpet •Subtle Sage Cityline - 117!Splash Carpet 'Subtle Sage Cityline - 118 S P lash Carpet 119' . Subtle .._. Sage Cityline - ... _ .....-... 120. - - - 121 - - - 122; - - - 123 Splash CarpetSubtle Sage 'Cityline 124 Splash Carpet SSubtle Sage Cityline 125 :Splash Carpet Subtle Sage ;Cityline 126&Splash Carpet Subtle Sage !Cityline 127,Splash Carpet Subtle Sage :Cityline 128lSplash Carpet Subtle Sage Cityline 129 Splash Carpet •Subtle Sage ;Cityline 1307 - _ i - 131 Splash Carpet Subtle Sage ;Cityline 132 ;Splash Carpet .Subtle SageI Cityline 133Splash Carpet Subtle Sage !Cityline 134 Splash Carpet Subtle Sage :Cityline 135ISplash Carpet :Subtle Sage 1Cityline 136 'Splash Carpet Subtle Sage ;Cityline 'Subtle :Sage. C. Gray, Yarrow, 1 137 VCT- 1,2,3,4 :Black !Cityline ;Olivine 'Admin Corridors 'Splash Carpet :Subtle Sage ; Cityline - ;Olivine ;Student Corridors Subtle Sage Cityline T 2DLC 20 (Patch only - new walls) ;Olivine Second Floo i 200 - - - 201 - I - 202 Splash Carpet Subtle Sage Cityline 203. Splash Carpet Subtle SagelCityline 204 Splash Carpet Subtle Sage ;Citylin 205;Splash Carp Subtle Sage ;Cityline 206 Splash Carpet Subtle Sage !Cityline 207 Splash Carpet Subtle Sage I Cityline Splash Carpet Subtle Sage !Cityline _ _ 209 Splash Carpet Subtle Sage j Cityline 210 Splash Carpet Subtle Sage ;Cityline 211 Splash Carpet Subtle Sage ;Cityline 212 Splash Carpet Subtle Sage jCityline 213 Splash Carpet Subtle Sage 1Cityline _ ......_ 214 - Subtle Sage Black Tie 215 Y Subtle Sage (Black Tie 1 216 Splash Carpet Subtle Sage Cityline L 217 Splash Carpet Subtle Sage Cityline fi 2181Splash Carpet Subtle Sage ;Cityline 219 - - ! 220ry .. t. ...... - r ._....... 221 - ..J .. - ._.._.. _. _.W ._... .. _..._..__ :.....__.._... _ .__ � ... _ 222 - - - 1 - t p 22315lash Ca et Subtle Sae ,Cit lin 'Olivine Student Corridors r - Subtle SagejCity 1 2DLC 20 (Patch only new walls) ! On e Olivine Olivine Olivine Olivine !Olivine :Olivine ; Olivine ; Olivine !Olivine O !Olivine _ ;Olivine !Jet Black_ !Olivine Jet Black_ ?Olivine Olivine Olivine Olivine :Olivine Olivine __',Olivine_ ;Olivine Olivine 101ivine Olivine TOlivine Olivine Olivine Olivine Olivine Olivine Olivine `Olivine Olivine Olivine - _Olivine Olivine Olivine - 'Olivine -- rOlivine - tOhvine - ;Jet Black !Jet Black ;Olivine - _.. Olivine Olivine ', II �1i3 wl 1 ... ofolyAnig FINISH SCHEDULE SYMBOLING. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL SIZE CONTACT NOTES CPT -1 GENERAL CARPET PATCRAFT SPLASH 10060 60605 SWAN DIVE NA NA BILL COTHRAN 1-800-713-6697 GLUE DOWN EXT. 5225 FOR NATIONAL ACCT. INFO 1 VCT 1 I VINYL COMPOSITION ARMSTRONG STONE TEX 52143 NA 12" X 12" SCOTT MAHER 1 -800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -2 VINYL COMPOSITION ARMSTRONG STONE TEX 52139 NA 12" X 12" SCOTT MAHER 1SOD- 356 9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -3 VINYL COMPOSITION ARMSTRONG STONE TEX 52155 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT-4 VINYL COMPOSITION ARMSTRONG STONE TEX 52153 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO ® VINYL COMPOSITION ARMSTRONG STONE TEX 52127 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -6 VINYL COMPOSITION ARMSTRONG STONE TEX 52144 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO GENERAL PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR #1165 ITT SUBTLE SAGE NA NA MIKE MANETTA 317-870-0351 NA EGGSHELL EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL PAINT PITTSBURG PAINT PURE PERFORMANCE #1159 ITT CITYLINE NA NA MIKE MANETTA 317-870-0351 ALL AREA EXCEPT CJ LAB INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL PAINT / PITTSBURG PAINT PURE PERFORMANCE #11007 ITT BLACK TIE NA NA MIKE MANETTA 317-870-0351 CHAIR RAIL IN CJ LAB CEILING PAINT INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO WHITE BOARD TRIM PITTSBURG PAINT PURE PERFORMANCE #1217 ITT BLUE BLAZER NA 12 "WIDE BOARDER MIKE MANETTA 317 - 870 -0351 NA PAINT INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO SPEEDHIDE INTERIOR #6165 ITT CONNECTED MIKE MANETTA 317 - 870 -0351 ACCENT PAINT PITTSBURG PAINT EGGSHELL GREY NA NA EXT, 611 FOR NATIONAL ACCT. INFO NA 0 ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR #212 6 ITT YARROW NA NA MIKE MANETTA 317- 870 -0351 NA !. RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1158 ITT OYSTER EGGSHELL EXT. 611 FOhNATIONALACCT.INFO NA NA MIKE MANETTA 317 - 870 -0351 NA INTERIOR SEMI -GLOSS WHITE/ SATIN FINISH EXT. 611 FOR NATIONAL ACCT. INFO RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1900 ITT LIMINOUS NA NA MIKE MANETTA 317-870-0351 NA INTERIOR SEMI -GLOSS WHITE/ FLAT FINISH EXT. 611 FOR NATIONAL ACCT. INFO WALL COVERING D. L . COUCH 2DLG20 NA NA 200z, TYPE 11, 54" WIDE SHANNON WEIRICK 800 - 433 -0790 WALLS BELOW CHAIR RAIL IN FOR NATIONAL ACCT. INFO STUDENT CORRIDOR WALL COVERING D. L . COUCH 2DLCO9 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800- 433 -0790 LOBBY WALLS FOR NATIONAL ACCT. INFO B -1 RUBBER BASE ARMSTRONG NA 06 OLIVINE NA 4" NA ALL AREA EXCEPT CJ LAB B -2 RUBBER BASE ARMSTRONG NA 60 JET BLACK NA 4" NA CJ LAB 0 SOLID SURFACING CORIAN PRAIRIE (E) NA NA NA NA NA PL -1 PLASTIC LAMINATE WILSONART 0478 -60 AMAZON NA NA NA NA Marvin Ste REVISIONS /ISSUANCE: CHECKED BY: GH, GG DATE: sociates, LLc 7 design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028-000 SCALE: NO. REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION GENERAL REVISION PERMIT REVISION AS NOTED DATE 5/6/08 6/5/08 6/6/08 10/24/08 RECEIVED II GATEWAY CORPORATE CENTER BUILDING #7 TENANT: 12720 GATEWAY DRIVE TU K WI LA, WA 98168 ORGE I. 'STATE (.2 F OCODIIEtOVTi: PERMIT ITT TECHNICAL INSTITUTE ENTER 209 210 211 SHEET TITLE: SECOND FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. TI -6.1 OF 12 ■ CD CD CD CD 0 0 3 0 up 0 ci cn c.� z CC J CO N U 6 U CV I1- CD -J N O I N rn Q Ed U d I NII�� o : a i 2' � E • 1 T.. - 225 t ._ - _ . L .. t 4 ..1 =.4; I' J iI e+ l? e is ' III i tgrILI i . , iVY •u "l^ ,� 1 dh� •+"Pso II"a�M�''C�lke LOBBY 1/8" =1' -0" FINISH NOTES: 1. ALL FINISHES ARE TO BE REPLACED WITH NEW UNLESS NOTED OTHERWISE 2. ALL WALLS TO RECEIVE 3. ALL ROOMS TO RECEIVE 4. BASE B -1 TO BE USED THROUGHOUT UNLESS NOTED OTHERWISE. 5. ALL CHART RAILS TO RECEIVE UNLESS NOTED OTHERWISE 6. PROVIDE FINISH SUBMITTALS FOR VERIFICATION THAT MATERIALS ARE STILL IN PRODUCTION AND THAT THEY MATCH EXISTING. CPT -1 SECOND FLOOR PLAN NORTH lti>i'I' ANIR Ililll'iin�t�`�i mliahllW�lliliu. iBlill :V'�MIIIII' w�itrtGi'tt9 Praii'il�t USN UNLESS NOTED OTHERWISE. FINISH KEYNOTES: O PAINT WALL WHERE REQUIRED IN ADJACENT SUITE 0 PAINT TO MATCH EXISTING LOBBY FINISH ® FLOORING, PAINT, AND BASE ARE EXISTING TO REMAIN THIS ROOM Q ALL EXISTING WALL COVER IN STUDENT CORRIDOR IS TO REMAIN. PATCH AS REQUIRED. ONLY PROVIDE NEW WALL COVERING ON NEW PARTITIONS. FLOORING LEGEND ❑ VCT- 1NCT -5 (SEE PLAN) • VCT -2 VCT -3 ✓ VCT-4 ! VCT -6 First Floor ROOM BY ROOM FINISH SCHEDULE Flooring Wall Paint Trim Paint ;Vinyl Wall Covering Base 100 Splash Carpet - ,Cityline 2DLC 09 101 Splash Carpet Subtle Sage ;Cityline ' - 102 . Splash Carpet Subtle Sage ;Cityline - 103 :Splash Carpet Subtle Sage ;Cityline - 104 Splash Carpet .Subtle Sage jCityline - 105 :Splash Carpet . Subtle Sage ;Cityline - 106 ;Splash Carpet 'Subtle Sage - 107 ,Splash Carpet ! Subtle Sage Cityline - 108 . Splash Carpet - et t . Subtle Sage Cityline ' - - - - - - - - . ... ......__ .... . .... ..... 109!Splash Carpet Subtle Sage Cityline - 110 !Splash Carpet ; Subtle Sage Cityline - .111 ;Splash Carpet 'Subtle Sage {Cityline - 112 ;Splash Carpet Subtle Sage !Cityline - 113, - :Subtle Sage ;Black Tie - 114; - ; Subtle Sage jCityline i - 115'VCT- 5 .Subtle Sage !Black Tie - 116 Splash Carpet •Subtle Sage Cityline - 117!Splash Carpet 'Subtle Sage Cityline - 118 S P lash Carpet 119' . Subtle .._. Sage Cityline - ... _ .....-... 120. - - - 121 - - - 122; - - - 123 Splash CarpetSubtle Sage 'Cityline 124 Splash Carpet SSubtle Sage Cityline 125 :Splash Carpet Subtle Sage ;Cityline 126&Splash Carpet Subtle Sage !Cityline 127,Splash Carpet Subtle Sage :Cityline 128lSplash Carpet Subtle Sage Cityline 129 Splash Carpet •Subtle Sage ;Cityline 1307 - _ i - 131 Splash Carpet Subtle Sage ;Cityline 132 ;Splash Carpet .Subtle SageI Cityline 133Splash Carpet Subtle Sage !Cityline 134 Splash Carpet Subtle Sage :Cityline 135ISplash Carpet :Subtle Sage 1Cityline 136 'Splash Carpet Subtle Sage ;Cityline 'Subtle :Sage. C. Gray, Yarrow, 1 137 VCT- 1,2,3,4 :Black !Cityline ;Olivine 'Admin Corridors 'Splash Carpet :Subtle Sage ; Cityline - ;Olivine ;Student Corridors Subtle Sage Cityline T 2DLC 20 (Patch only - new walls) ;Olivine Second Floo i 200 - - - 201 - I - 202 Splash Carpet Subtle Sage Cityline 203. Splash Carpet Subtle SagelCityline 204 Splash Carpet Subtle Sage ;Citylin 205;Splash Carp Subtle Sage ;Cityline 206 Splash Carpet Subtle Sage !Cityline 207 Splash Carpet Subtle Sage I Cityline Splash Carpet Subtle Sage !Cityline _ _ 209 Splash Carpet Subtle Sage j Cityline 210 Splash Carpet Subtle Sage ;Cityline 211 Splash Carpet Subtle Sage ;Cityline 212 Splash Carpet Subtle Sage jCityline 213 Splash Carpet Subtle Sage 1Cityline _ ......_ 214 - Subtle Sage Black Tie 215 Y Subtle Sage (Black Tie 1 216 Splash Carpet Subtle Sage Cityline L 217 Splash Carpet Subtle Sage Cityline fi 2181Splash Carpet Subtle Sage ;Cityline 219 - - ! 220ry .. t. ...... - r ._....... 221 - ..J .. - ._.._.. _. _.W ._... .. _..._..__ :.....__.._... _ .__ � ... _ 222 - - - 1 - t p 22315lash Ca et Subtle Sae ,Cit lin 'Olivine Student Corridors r - Subtle SagejCity 1 2DLC 20 (Patch only new walls) ! On e Olivine Olivine Olivine Olivine !Olivine :Olivine ; Olivine ; Olivine !Olivine O !Olivine _ ;Olivine !Jet Black_ !Olivine Jet Black_ ?Olivine Olivine Olivine Olivine :Olivine Olivine __',Olivine_ ;Olivine Olivine 101ivine Olivine TOlivine Olivine Olivine Olivine Olivine Olivine Olivine `Olivine Olivine Olivine - _Olivine Olivine Olivine - 'Olivine -- rOlivine - tOhvine - ;Jet Black !Jet Black ;Olivine - _.. Olivine Olivine ', II �1i3 wl 1 ... ofolyAnig FINISH SCHEDULE SYMBOLING. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL SIZE CONTACT NOTES CPT -1 GENERAL CARPET PATCRAFT SPLASH 10060 60605 SWAN DIVE NA NA BILL COTHRAN 1-800-713-6697 GLUE DOWN EXT. 5225 FOR NATIONAL ACCT. INFO 1 VCT 1 I VINYL COMPOSITION ARMSTRONG STONE TEX 52143 NA 12" X 12" SCOTT MAHER 1 -800- 356 -9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -2 VINYL COMPOSITION ARMSTRONG STONE TEX 52139 NA 12" X 12" SCOTT MAHER 1SOD- 356 9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -3 VINYL COMPOSITION ARMSTRONG STONE TEX 52155 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT-4 VINYL COMPOSITION ARMSTRONG STONE TEX 52153 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO ® VINYL COMPOSITION ARMSTRONG STONE TEX 52127 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO VCT -6 VINYL COMPOSITION ARMSTRONG STONE TEX 52144 NA 12" X 12" SCOTT MAHER 1-800-356-9301 NA TILE EXT. 8962 FOR NATIONAL ACCT. INFO GENERAL PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR #1165 ITT SUBTLE SAGE NA NA MIKE MANETTA 317-870-0351 NA EGGSHELL EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL PAINT PITTSBURG PAINT PURE PERFORMANCE #1159 ITT CITYLINE NA NA MIKE MANETTA 317-870-0351 ALL AREA EXCEPT CJ LAB INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL PAINT / PITTSBURG PAINT PURE PERFORMANCE #11007 ITT BLACK TIE NA NA MIKE MANETTA 317-870-0351 CHAIR RAIL IN CJ LAB CEILING PAINT INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO WHITE BOARD TRIM PITTSBURG PAINT PURE PERFORMANCE #1217 ITT BLUE BLAZER NA 12 "WIDE BOARDER MIKE MANETTA 317 - 870 -0351 NA PAINT INTERIOR SEMI -GLOSS EXT. 611 FOR NATIONAL ACCT. INFO SPEEDHIDE INTERIOR #6165 ITT CONNECTED MIKE MANETTA 317 - 870 -0351 ACCENT PAINT PITTSBURG PAINT EGGSHELL GREY NA NA EXT, 611 FOR NATIONAL ACCT. INFO NA 0 ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR #212 6 ITT YARROW NA NA MIKE MANETTA 317- 870 -0351 NA !. RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1158 ITT OYSTER EGGSHELL EXT. 611 FOhNATIONALACCT.INFO NA NA MIKE MANETTA 317 - 870 -0351 NA INTERIOR SEMI -GLOSS WHITE/ SATIN FINISH EXT. 611 FOR NATIONAL ACCT. INFO RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE #1900 ITT LIMINOUS NA NA MIKE MANETTA 317-870-0351 NA INTERIOR SEMI -GLOSS WHITE/ FLAT FINISH EXT. 611 FOR NATIONAL ACCT. INFO WALL COVERING D. L . COUCH 2DLG20 NA NA 200z, TYPE 11, 54" WIDE SHANNON WEIRICK 800 - 433 -0790 WALLS BELOW CHAIR RAIL IN FOR NATIONAL ACCT. INFO STUDENT CORRIDOR WALL COVERING D. L . COUCH 2DLCO9 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800- 433 -0790 LOBBY WALLS FOR NATIONAL ACCT. INFO B -1 RUBBER BASE ARMSTRONG NA 06 OLIVINE NA 4" NA ALL AREA EXCEPT CJ LAB B -2 RUBBER BASE ARMSTRONG NA 60 JET BLACK NA 4" NA CJ LAB 0 SOLID SURFACING CORIAN PRAIRIE (E) NA NA NA NA NA PL -1 PLASTIC LAMINATE WILSONART 0478 -60 AMAZON NA NA NA NA Marvin Ste REVISIONS /ISSUANCE: CHECKED BY: GH, GG DATE: sociates, LLc 7 design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028-000 SCALE: NO. REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION GENERAL REVISION PERMIT REVISION AS NOTED DATE 5/6/08 6/5/08 6/6/08 10/24/08 RECEIVED II GATEWAY CORPORATE CENTER BUILDING #7 TENANT: 12720 GATEWAY DRIVE TU K WI LA, WA 98168 ORGE I. 'STATE (.2 F OCODIIEtOVTi: PERMIT ITT TECHNICAL INSTITUTE ENTER 209 210 211 SHEET TITLE: SECOND FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. TI -6.1 OF 12 ■ LJJ H- rn LD CC ca z CC uJ w W cc 4 0 F-- I L U d cn 0 a I co m ( 0 ' U) I N N II u oT o ai 6.2 w 0 . o�cnox SINGLE WHITE BOARD ELEVATION INTERNET CAFE VENDING ELEVATION N NA 5 1' -0" 9 \ PAINT 3" BEYOND WHITE BOARD ,WHITE BOARD— \ CHAIR RAIL SEE FINISH SCHEDULE FOR PAINT COLOR 9" CLOCK - GRANGER #5H352 INSTALL TOP OF OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD / 1.-0" 7' 12" BAND OF SEMI -GLOSS (P4) PAINT AROUND TOP AND SIDES OF WHITE BOARD. NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 101 NA 1/2 " =1' -0" NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 11 I N VERIFY NUMBER OF WHITE BOARDS FOR EACH ROOM DOUBLE WHITE BOARD ELEVATION TOP OF STRUCTURE PAINT INSIDE WALL AND TOP OF SOFFIT P -5, TYP. SCHEDULED EQUIPMENT SCHEDULED BASE 1/2 " =1' -0" NA 121 NA EXIST. LIGHT SOFFIT EXIST. MIRROR NEW COUNTER TOP PROVIDE SUPPORTS AS REQUIRED RESTROOM COUNTER VARIFY WITH EQUIMENT VENDING SOFFIT DETAIL GWB - PAINT P -6 C) 1/2 " =1' -0" EXISTING DECKING SUPPORTS AS REQUIRED GWB - PAINT P -6 1" =1' -0" NA METAL STDS. AND GLASS SHELVES TO MATCH EXISTING EXIST. DISPLAY CASE 13 SLIDING GLASS DOORS W/ LOCK I LOBBY DISPAY CASE SYMBOL /NO. EQ -1 NA rm f/ MANUF. ZURN CORIAN STYLE 26916 NA EQUIPMENT SCHEDULE DESCRIPTION AQUASENSE "A" BATTERY POWERED LAVATORY FAUCET. VANDAL RESISTANT AERATOR. CORIAN INTEGRAL SINK - GLACIER WHITE, 4" CENTERS, COLORS WHITE, 1 1/4" TRAP. ANGLED WALL j 112 " =1' -0" 1/2 " =1' -0" NA NA NA N A GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: G- •ROEI1. .., , OW III STATE OF WASHINGTON sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JM JOB NO 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE RECEIVED 5/6/08 6/5/08 6/6/08 10/24108 CITY OF TUKWILA TT 9 1 7(1118 PERMIT CENTER ELEVATIONS AND DETAILS TI -7 OF 12 ( 9U CLOCK - GRANGER #5H352 INSTALL TOP OF OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD \ AL GN- / // EQ 1 -0" / // PAINT AROUND TOP AND SIDES OF WHITE BOARD. \ PAINT 3" BEYOND WHITE BOARD '7 WHITE BOARD ' -2 EQ -1 to \ \ CHAIR RAIL SEE FINISH SCHEDULE - Q FOR PAINT COLOR N a 7 l 7 \ r U u VARIES LJJ H- rn LD CC ca z CC uJ w W cc 4 0 F-- I L U d cn 0 a I co m ( 0 ' U) I N N II u oT o ai 6.2 w 0 . o�cnox SINGLE WHITE BOARD ELEVATION INTERNET CAFE VENDING ELEVATION N NA 5 1' -0" 9 \ PAINT 3" BEYOND WHITE BOARD ,WHITE BOARD— \ CHAIR RAIL SEE FINISH SCHEDULE FOR PAINT COLOR 9" CLOCK - GRANGER #5H352 INSTALL TOP OF OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD / 1.-0" 7' 12" BAND OF SEMI -GLOSS (P4) PAINT AROUND TOP AND SIDES OF WHITE BOARD. NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 101 NA 1/2 " =1' -0" NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 11 I N VERIFY NUMBER OF WHITE BOARDS FOR EACH ROOM DOUBLE WHITE BOARD ELEVATION TOP OF STRUCTURE PAINT INSIDE WALL AND TOP OF SOFFIT P -5, TYP. SCHEDULED EQUIPMENT SCHEDULED BASE 1/2 " =1' -0" NA 121 NA EXIST. LIGHT SOFFIT EXIST. MIRROR NEW COUNTER TOP PROVIDE SUPPORTS AS REQUIRED RESTROOM COUNTER VARIFY WITH EQUIMENT VENDING SOFFIT DETAIL GWB - PAINT P -6 C) 1/2 " =1' -0" EXISTING DECKING SUPPORTS AS REQUIRED GWB - PAINT P -6 1" =1' -0" NA METAL STDS. AND GLASS SHELVES TO MATCH EXISTING EXIST. DISPLAY CASE 13 SLIDING GLASS DOORS W/ LOCK I LOBBY DISPAY CASE SYMBOL /NO. EQ -1 NA rm f/ MANUF. ZURN CORIAN STYLE 26916 NA EQUIPMENT SCHEDULE DESCRIPTION AQUASENSE "A" BATTERY POWERED LAVATORY FAUCET. VANDAL RESISTANT AERATOR. CORIAN INTEGRAL SINK - GLACIER WHITE, 4" CENTERS, COLORS WHITE, 1 1/4" TRAP. ANGLED WALL j 112 " =1' -0" 1/2 " =1' -0" NA NA NA N A GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: G- •ROEI1. .., , OW III STATE OF WASHINGTON sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JM JOB NO 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE RECEIVED 5/6/08 6/5/08 6/6/08 10/24108 CITY OF TUKWILA TT 9 1 7(1118 PERMIT CENTER ELEVATIONS AND DETAILS TI -7 OF 12 ( 9U CLOCK - GRANGER #5H352 INSTALL TOP OF OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD \ AL GN- / PAINT 3" BEYOND WHITE BOARD - — 12" BAND OF SEMI-GLOSS (P4) 1 -0" / / / PAINT AROUND TOP AND SIDES OF WHITE BOARD. \ PAINT 3" BEYOND WHITE BOARD '7 WHITE BOARD ' '7— WHITE BOARD — -" to \ \ CHAIR RAIL SEE FINISH SCHEDULE - Q FOR PAINT COLOR N a LJJ H- rn LD CC ca z CC uJ w W cc 4 0 F-- I L U d cn 0 a I co m ( 0 ' U) I N N II u oT o ai 6.2 w 0 . o�cnox SINGLE WHITE BOARD ELEVATION INTERNET CAFE VENDING ELEVATION N NA 5 1' -0" 9 \ PAINT 3" BEYOND WHITE BOARD ,WHITE BOARD— \ CHAIR RAIL SEE FINISH SCHEDULE FOR PAINT COLOR 9" CLOCK - GRANGER #5H352 INSTALL TOP OF OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD / 1.-0" 7' 12" BAND OF SEMI -GLOSS (P4) PAINT AROUND TOP AND SIDES OF WHITE BOARD. NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 101 NA 1/2 " =1' -0" NA VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT 11 I N VERIFY NUMBER OF WHITE BOARDS FOR EACH ROOM DOUBLE WHITE BOARD ELEVATION TOP OF STRUCTURE PAINT INSIDE WALL AND TOP OF SOFFIT P -5, TYP. SCHEDULED EQUIPMENT SCHEDULED BASE 1/2 " =1' -0" NA 121 NA EXIST. LIGHT SOFFIT EXIST. MIRROR NEW COUNTER TOP PROVIDE SUPPORTS AS REQUIRED RESTROOM COUNTER VARIFY WITH EQUIMENT VENDING SOFFIT DETAIL GWB - PAINT P -6 C) 1/2 " =1' -0" EXISTING DECKING SUPPORTS AS REQUIRED GWB - PAINT P -6 1" =1' -0" NA METAL STDS. AND GLASS SHELVES TO MATCH EXISTING EXIST. DISPLAY CASE 13 SLIDING GLASS DOORS W/ LOCK I LOBBY DISPAY CASE SYMBOL /NO. EQ -1 NA rm f/ MANUF. ZURN CORIAN STYLE 26916 NA EQUIPMENT SCHEDULE DESCRIPTION AQUASENSE "A" BATTERY POWERED LAVATORY FAUCET. VANDAL RESISTANT AERATOR. CORIAN INTEGRAL SINK - GLACIER WHITE, 4" CENTERS, COLORS WHITE, 1 1/4" TRAP. ANGLED WALL j 112 " =1' -0" 1/2 " =1' -0" NA NA NA N A GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A PERMIT REVISION GENERAL REVISION PERMIT REVISION TENANT: SHEET TITLE: G- •ROEI1. .., , OW III STATE OF WASHINGTON sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: JM JOB NO 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE RECEIVED 5/6/08 6/5/08 6/6/08 10/24108 CITY OF TUKWILA TT 9 1 7(1118 PERMIT CENTER ELEVATIONS AND DETAILS TI -7 OF 12 cO C 4 2 ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL CONC CONST CONT CPT CT DIA DIM DN DR DWG EA ELEC ELEV EXIST EXT FD FIN FLR FLUOR FR FT FURN GA GALV GL GWB HC HDWE HM HORIZ HT HVAC IN INCL INSUL INT JT LF ACOUSTICAL CEILING TILE ADJACENT /ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELECTRIC(AL) ELEVATION (VIEW) EXISTING EXTERIOR FLOOR DRAIN FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH/ FURNISHING GAUGE GALVANIZED GLASS /GLAZING GYPSUM WALL BOARD HIGH HOLLOW CORE HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT LINEAL FOOT ABBREVIATIONS MAX MECH MFR MIN MISC MTD MTL N NA NIC NO. ( #) NOM NTS OC OPNG OPP ORIG P.J. PL PLAM PLYWD PNL PR PTN RB REF (R) REINF REQ REV RM RO SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP T.B.D. TEL TYP U.C. U.N.O. VCT VERT V.I.F. W/ W/0 WC WD WS MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PANEL JOINT PLATE PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION RADIUS RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TO BE DETERMINED TELEPHONE TYPICAL UNDER CABINET UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WITHOUT WALLCOVERING WOOD WORKSTATION r N A rou'r , rawk, r r.i ra a k ,„__ 4 Virieff 66' EGRESS PATH r Ar I r � r4tor )7 4,; 4 r --- , /rord .,,,11, ..,i7. COMMON PATH OF EGRESS = 75' MAX. 3 EXITING PLAN • 4 !A!1!A!!t1!i!! L 1 I_, i i i I i I I I L l � ' CONT. 3 5/8" ‘1/4" 25 GA. TRAC (2) #10 SCREWS @ 'r 24" O.C. LINE OF CEILING GRID BEYOND, SEE R.C.P. FINISH FLOOR SUBFLOOR a N NEW l K 1 RELOCATED FIRST FLOOR AREA OF WORK 3 5/8" 5 " 12 CONSTRUCTION LEGEND 78' EGRESS PATH SEISMIC BRACING PER 9/TI -1 �I r - - Av .a =��i 1__R- Fir r 1 4407 prt;4 ,_ A AI 1, AIF rrr 1 i I A p V ,, r i„......,* 4 ddr A O ACOUSTICAL BATT INSULATION ABOVE CEILING TO EXTEND 24" BEYOND EACH SIDE OF WALL Ills LINE OF CEILING GRID BEYOND, SEE R.C.P. SUSPENDED ACOUSTIC TILE CEILING - DO NOT CUT CONT. 'L' METAL TRIM W/ PAPER WING 5/8" FIRE - RETARDANT TREATED PLYWOOD BLOCKING @ WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: 20" WIDE GALV. SHEET METAL (IN LIEU OF WOOD BLOCKING) 3 5/8" x 25 GA. GALV. STEEL STUD @ 16" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. 5/8" TYPE "X" GWB EACH SIDE PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS. SCHEDULED BASE CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN EMBEDMENT. NOTES: 1. SEAL BOTTOM OF WALL TO FLOOR SLAB USING ACOUSTICAL CAULKING CONTINUOUS BOTH SIDES. 2. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION IS ONE HOUR CONSTRUCTION. NEW CORRIDORS TO BE BUILT TO MATCH. STANDARD TENANT SOUND PARTITION NTS EXISTING BUILDING CORE /COMMON AREAS TO REMAIN UNALTERED EXISTING TENANT INTERIOR SOUND PARTITION: SEE DETAIL 7/TI -1. U.N.O. EXISTING CONSTRUCTION TO BE DEMOLISHED. NEW TENANT INTERIOR SOUND PARTITION: SEE DETAIL 7/TI -1, U.N.O. EXISTING TENANT DEMISING PARTITION NEW OR RELOCATED B/S RELITE PARTITION TO MATCH EXISTING (SEE PLAN FOR DIM.) (TEMPERED SAFETY GLASS WITHIN 2' -0" OF DOOR JAMB AND LESS THAN 1' -6" SILL HEIGHT A.F.F.) NEW CHAIR RAIL COMMON PATH OF EGRESS = 96' MAX. 13 NO CHANGE TO EXISTING SQUARE FOOTAGE ON EITHER FLOOR ACOUSTICAL CEILING SYSTEMS INSTALLATION INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9. IN ACCORDANCE WITH ASTM C 635 & 6. SUSPENDED CEILING SUPPORT DATA LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PTNS THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SF. FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN. OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 IN. OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE AS REQUIRED BY CURRENT CODES. FOR INFORMATIONAL PURPOSED ONLY I SUSPENDED CEILING BRACING II% /II II�fI� r '"'- L--- 0 0) 45" SECOND FLOOR AREA OF WORK 45" 45" EXISTING NON -RATED CEILING GRID AND TILES EXISTING RATED CEILING GRID AND TILES 0 EXISTING B/S RECESSED DOWN LIGHT EXITING & OCCUPANCY INFORMATION FIRST FLOOR OFFICE: 10,199 SF / 100 =102 CLASSROOM: 6,248 SF / 20 = 312 LIBRARY: 675 SF / 50 =14 ASSEMBLY: 641 SF / 15 = 43 TOTAL OCCUPANCY LOAD = 471 SECOND FLOOR OFFICE: 6,180 SF / 100 = 62 CLASSROOM: 8,150 SF / 20 = 408 TOTAL OCCUPANCY LOAD = 470 (2) EXITS REQUIRED (3) PROVIDED EACH FLOOOR SECOND FLOOR 470 / 3 = 157 X 0.2 = 32" MIN. WIDTH AT EACH SECOND FLOOR EXIT FIRST FLOOR (470 + 157 + 157) 785X.02 =157" 157 < (36 + 72 + 72) OR 180° : OKAY HEAVY GAUGE WIRE "PIN ". MAIN RUNNER AT 4' -0" O.C. NORTH VERTICAL WIRE HANGER-NO. 12 GAUGE @ 4' -0" 0.0. OR NO. 10 GAUGE @ 5' -0" O.C. ALONG EACH MAIN RUNNER. - VERTICAL STRUT STABLING BAR @ 12' -0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. VERTICAL STRUT FASTENED TO MAIN RUNNER. CROSS RUNNER EXISTING B/S GYP BOARD CEILING EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE EXISTING 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN EXISTING B/S 1-0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO REMAIN NEW OR RELOCATED B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER EXISTING 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO BE REMOVED /RELOCATED NEW COVENTRY ARCHITECTURAL SERIES P2C PENDANT. AVIATION CABLE /COILED 10' CORD, DL12 CLEAR DOMED ACRYLIC LENS. I69- B/S SWITCH (*NEW) ▪ B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN) NEW 1/32" =1' -0" NTS A S 128TH ST. N VICINITY MAP SITE PLAN (2) #10 SCREWS 5130TH 5T. REVEAL (PAINT BLACK) OR MATCH EXISTING. 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. 122TH ST SITE 6' LIGHTING NOTES S 125T1-1 ST. 4I eat • I III I � CZ ��i�� /I � �� � 1,a l 9 I TYPICAL PARTITION BRACING NOTES: 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 9 TH SUSPENDED CEILING. NO CHANGE TO BUILDING STRUCTURE OR USE METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12-0". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SCHEDULED PARTITION LATERAL BRACING TENANT WALLS WO CASEWORK) NTS 8' MAX MAX MAX 8' MAX,,8' MAX -1' MAX 2' MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) NORTH EXISTING SITE DEVELOPMENT TO REMAIN AS IS NORTH P"N NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ABOVE TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (SEE FLOOR PLAN, TI-3) REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 9y NTS NTS 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 1-1/2"=V-0" 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING OF 1 FT CANDLE @ FLOOR. 3. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. UNDER SEPARATE PERMIT 4. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 6. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 7. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 8. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 9. RE- CIRCUIT SWITCHING AS NECESSARY. ALL NEW CLASSROOMS, INCLUDING LABS, TO HAVE DUAL SWITCHES. EACH SWITCH WILL CONTROL 50% OF THE LIGHT FIXTURES IN THESE ROOMS AND BE GROUPED INTO FRONT HALF AND REAR HALF OF ROOM. SCOPE OF WORK: TENANT IMPROVEMENT TO PART OF THE FIRST AND SECOND FLOOR FOR ADMINISTRATIVE OFFICE AND TECHNICAL TRAINING USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, OUTLETS AND FINISHES. CONSTRUCTION TYPE: Ill-B, SPRINKLERED FIRST FLOOR AREA OF SUITE: +/- 17,736 SECOND FLOOR AREA OF SUITE: +/- 14,330 OCCUPANCY: B OFFICE BUILDING CODE: WASHINGTON STATE BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 -ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE LEGAL DESCRIPTION 7 GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER TAX ID NUMBER: 271600 -00- 0070 -06 SITE ADDRESS 12720 GATEWAY RIVE TUKWILA, WA 98168 PROJECT DIRECTORY: TENANT: ITT TECHNICAL INSTITUTE 13000 NORTH MERIDIAN ST CARMEL, IN 46032 CONTACT: ADAM MERKLE 317 - 706 -9316 (PHONE) 317 - 571 -0140 (FAX) DESIGNER: MARVIN STEIN AND ASSOC., LLC 2221 5TH AVE. SEATTLE, WASHINGTON 98121 CONTACT: GALEN HOLDEN 206 -441 -1449 (PHONE) 206 - 441 -4361 (FAX) EMAIL - g.holden @marvinstein.com SEPARATE PERMIT REQUIRED FOR: L(1111echanical arlElectriati L'if umbing Gas Piping City of Tukwila BUILDING DIVISION 10 GENERAL NOTES 5 PROJECT INFORMATION 5. BY L.L. @T.E. INDICATES "BY LANDLORD AT TENANT'S EXPENSE" TI -1 COVER SHEET & DETAILS TI -2 FIRST FLOOR DEMOLITION PLAN TI -2.1 SECOND FLOOR DEMOLITION PLAN TI -3 FIRST FLOOR CONSTRUCTION PLAN TI -3.1 SECOND FLOOR CONSTRUCTION PLAN TI -6 FIRST FLOOR FINISH PLAN TI -6.1 SECOND FLOOR FINISH PLAN TI -7 ELEVATIONS AND DETAILS 15 DRAWING INDEX BUILDING OWNER: RREEF 16000 CHRISTENSEN RD SUITE 101 TUKWILA, WA 98188 CONTACT: NANCY ANDERSON EMAIL: nancy.anderson @rreef.com CONTRACTOR: T.B.D. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS FOR THIS PROJECT. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD, AS DRAWN OR SPECIFIED IN THE CONTRACT DOCUMENTS. 6. DIMENSIONS BETWEEN ELECTRICAL & TELEPHONE OUTLETS TO BE A MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 7. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS REQUIRED FOR THIS PROJECT. 8. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS, AS INDICATED HERE AND AS REQUIRED BY LOCAL JURISDICTIONS, 9. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, FIRE ALARM & SECURITY SYSTEM RENOVATIONS SHALL BE PROVIDED UNDER SEPARATE PERMITS. 10. ALL FURNITURE MOVING (INCLUDING SYSTEMS /CUBICLE FURNITURE) SHALL BE PERFORMED BY THE CONTRACTOR. GENERAL CONDITIONS PRICING SHOULD INCLUDE ALL COSTS TO HANDLE FURNITURE. 11. PAINT COSTS SHALL INCLUDE THE REMOVAL OF DRYWALL ANCHORS AND ANY PATCHING /REPAIR WORK FOR APPROXIMATELY 300 MISC. HOLES IN WALLS DUE TO ARTWORK/PROMOTIONAL WALL HANGINGS. 12. CONTRACTOR SHALL CREATE, UPDATE (WEEKLY) AND WORK WITHIN A PUBLISHED CONSTRUCTION SCHEDULE. 13. CONTRACTOR SHALL MAKE A REASONABLE EFFORT TO COMMUNICATE WITH THE DIRECTOR OF THE SCHOOL CONCERNING DAY -TO -DAY CHANGES IN THE WORK SCHEDULE, PARTICULARLY WHEN WORKING IN OCCUPIED SPACES. 14. CONTRACTOR SHALL MAINTAIN A PRACTICE OF DAILY CLEANUP, INCLUDING CONSTRUCTION DEBRIS, TOOLS, EQUIPMENT, AND MACHINERY. EXTRA CARE SHALL BE TAKEN TO CLEAN AROUND CONSTRUCTION DUMPSTERS. DUMPSTERS SHALL NOT SIT DIRECTLY ON ASPHALT OR CONCRETE, NOR SHALL THEY BE PLACED ON SOIL. PLYWOOD SHALL BE USED AS A BARRIER BETWEEN DUMPSTER BEARING POINTS AND HARD SURFACES. 15. NEW MATERIAL SHALL BE STACKED IN A 'NEAT AND ORDERLY' FASHION, AWAY FROM HIGH TRAFFIC AREAS AND OCCUPIED SPACES. 16, IF NECESSARY, CONTRACTOR SHALL PRODUCE AND MAINTAIN ON -SITE STORAGE CONTAINERS. CONSTRUCTION RELATED MATERIAL AND EQUIPMENT SHALL NOT BE STORED IN OCCUPIED ITT SPACES. FILE C Permit No. TI -4 FIRST FLOOR REFLECTED CEILING PLAN TI -4,1 SECOND FLOOR REFLECTED CEILING PLAN D py Plar review approval is subject to errs and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt 0 approved Field Copy and Tvidltions is acknowledged: Ety Date: Cit of Tukwila RI Ili DIVISION REVIEWED FOR I CODE COMPLIANCE APPROVED JUN 13 2008 ■. C' Of Tukwila BUILDING DIVISION TI - FIRST FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -5.1 SECOND FLOOR ELECTRICAL /COMMUNICATIONS PLAN NA NO. AN GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste CHECKED BY: GH, GG REVISIONS /ISSUANCE: RECEIVED 1TY OF zi IK'M'_A ERMIT CENTER TENANT: SHEET TITLE: planning 6512 RE A GEO H. .DFELLG' . S ATE OF ASHING IN • 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION ITT TECHNICAL INSTITUTE DATE: 5/6/08 11 LIGHTING LEGEND NTS 14 REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design SCALE: AS NOTED DATE 5/6/08 6/5108 0 ' - I 1 O N LTR# i COVER SHEET & DETAILS OF 12 �r• ±r. I** K B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET (T=TIMER) B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET BIS WALL MOUNTED COMBINATION VOICE/DATA OUTLET BIS WALL MOUNTED DEDICATED VOICE LINE OUTLET B/S WALL MOUNTED JUNCTION BOX NOTE ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) I ELECTRICAL LEGEND 0 i win B. RELOCATED B/S 20 MIN. RATED 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN B/S HOLLOW METAL FRAME. PROVIDE KICKPLATE IF NOT EXISTING. (TOUCH UP TO LIKE NEW CONDITION) • I I .aI r I I I III I I " I • E. NEW B/S 1 HOUR. RATED 3' -0" WID X 7' -0" HIGH SOLID CORE MAPLE WO DOOR IN B/S HOLLOW METAL FRAME, SMOKE SEALED. I 6" UNLESS OTHERWISE NOTED DOOR NUMBER TYPE OF DOOR A PAIR OF B/S 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN H B 0 XI IN POI' HARDWARE a. B/S LOCKSET AND CLOSER 0 T NOTES: 1. THRESHOLDS AT DOORWAYS SHALL BE z' MAXIMUM IN HEIGHT. DOOR IN B/S HOLLOW METAL FRAME (TOUCH UP TO LIKE NEW CONDITION) D. PAIR OF B/S 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5,0 POUNDS (22,2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. SIDE LIGHTS W/ 2" HOLLOW METAL FRAMES EQUAL SECTIONS OF GLASS SEE PLAN FOR OVERALL DIMENSIONS DOOR & HARDWARE SCHEDULE X -0" ©© L C MATCH EXISTING L Y HARDWARE NEEDS TO BE RE- KEYED) HAGER KICK PLATE MATCH EXISTING SCHEDULED BASE NTS j j i / / / / \ \ \ \ \ \ / i / 0 / - 210.' r I 2 ' -0 1, j - I-I 21 -0" 2' -0" A IA ('I C Tt=\Ar7CDf=1l e A CCTV (T ACC Af2C❑ VIM' DI ATG cO C 4 2 ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL CONC CONST CONT CPT CT DIA DIM DN DR DWG EA ELEC ELEV EXIST EXT FD FIN FLR FLUOR FR FT FURN GA GALV GL GWB HC HDWE HM HORIZ HT HVAC IN INCL INSUL INT JT LF ACOUSTICAL CEILING TILE ADJACENT /ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN CONCRETE CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DIAMETER DIMENSION DOWN DOOR DRAWING EACH ELECTRIC(AL) ELEVATION (VIEW) EXISTING EXTERIOR FLOOR DRAIN FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH/ FURNISHING GAUGE GALVANIZED GLASS /GLAZING GYPSUM WALL BOARD HIGH HOLLOW CORE HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT LINEAL FOOT ABBREVIATIONS MAX MECH MFR MIN MISC MTD MTL N NA NIC NO. ( #) NOM NTS OC OPNG OPP ORIG P.J. PL PLAM PLYWD PNL PR PTN RB REF (R) REINF REQ REV RM RO SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP T.B.D. TEL TYP U.C. U.N.O. VCT VERT V.I.F. W/ W/0 WC WD WS MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PANEL JOINT PLATE PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION RADIUS RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION /REVERSE ROOM ROUGH OPENING SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TO BE DETERMINED TELEPHONE TYPICAL UNDER CABINET UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WITH WITHOUT WALLCOVERING WOOD WORKSTATION r N A rou'r , rawk, r r.i ra a k ,„__ 4 Virieff 66' EGRESS PATH r Ar I r � r4tor )7 4,; 4 r --- , /rord .,,,11, ..,i7. COMMON PATH OF EGRESS = 75' MAX. 3 EXITING PLAN • 4 !A!1!A!!t1!i!! L 1 I_, i i i I i I I I L l � ' CONT. 3 5/8" ‘1/4" 25 GA. TRAC (2) #10 SCREWS @ 'r 24" O.C. LINE OF CEILING GRID BEYOND, SEE R.C.P. FINISH FLOOR SUBFLOOR a N NEW l K 1 RELOCATED FIRST FLOOR AREA OF WORK 3 5/8" 5 " 12 CONSTRUCTION LEGEND 78' EGRESS PATH SEISMIC BRACING PER 9/TI -1 �I r - - Av .a =��i 1__R- Fir r 1 4407 prt;4 ,_ A AI 1, AIF rrr 1 i I A p V ,, r i„......,* 4 ddr A O ACOUSTICAL BATT INSULATION ABOVE CEILING TO EXTEND 24" BEYOND EACH SIDE OF WALL Ills LINE OF CEILING GRID BEYOND, SEE R.C.P. SUSPENDED ACOUSTIC TILE CEILING - DO NOT CUT CONT. 'L' METAL TRIM W/ PAPER WING 5/8" FIRE - RETARDANT TREATED PLYWOOD BLOCKING @ WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS) ALTERNATE #1 FOR BLOCKING: 20" WIDE GALV. SHEET METAL (IN LIEU OF WOOD BLOCKING) 3 5/8" x 25 GA. GALV. STEEL STUD @ 16" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. 5/8" TYPE "X" GWB EACH SIDE PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS. SCHEDULED BASE CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN EMBEDMENT. NOTES: 1. SEAL BOTTOM OF WALL TO FLOOR SLAB USING ACOUSTICAL CAULKING CONTINUOUS BOTH SIDES. 2. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION IS ONE HOUR CONSTRUCTION. NEW CORRIDORS TO BE BUILT TO MATCH. STANDARD TENANT SOUND PARTITION NTS EXISTING BUILDING CORE /COMMON AREAS TO REMAIN UNALTERED EXISTING TENANT INTERIOR SOUND PARTITION: SEE DETAIL 7/TI -1. U.N.O. EXISTING CONSTRUCTION TO BE DEMOLISHED. NEW TENANT INTERIOR SOUND PARTITION: SEE DETAIL 7/TI -1, U.N.O. EXISTING TENANT DEMISING PARTITION NEW OR RELOCATED B/S RELITE PARTITION TO MATCH EXISTING (SEE PLAN FOR DIM.) (TEMPERED SAFETY GLASS WITHIN 2' -0" OF DOOR JAMB AND LESS THAN 1' -6" SILL HEIGHT A.F.F.) NEW CHAIR RAIL COMMON PATH OF EGRESS = 96' MAX. 13 NO CHANGE TO EXISTING SQUARE FOOTAGE ON EITHER FLOOR ACOUSTICAL CEILING SYSTEMS INSTALLATION INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9. IN ACCORDANCE WITH ASTM C 635 & 6. SUSPENDED CEILING SUPPORT DATA LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PTNS THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 SF. FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2 IN. OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 IN. IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 IN. OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE AS REQUIRED BY CURRENT CODES. FOR INFORMATIONAL PURPOSED ONLY I SUSPENDED CEILING BRACING II% /II II�fI� r '"'- L--- 0 0) 45" SECOND FLOOR AREA OF WORK 45" 45" EXISTING NON -RATED CEILING GRID AND TILES EXISTING RATED CEILING GRID AND TILES 0 EXISTING B/S RECESSED DOWN LIGHT EXITING & OCCUPANCY INFORMATION FIRST FLOOR OFFICE: 10,199 SF / 100 =102 CLASSROOM: 6,248 SF / 20 = 312 LIBRARY: 675 SF / 50 =14 ASSEMBLY: 641 SF / 15 = 43 TOTAL OCCUPANCY LOAD = 471 SECOND FLOOR OFFICE: 6,180 SF / 100 = 62 CLASSROOM: 8,150 SF / 20 = 408 TOTAL OCCUPANCY LOAD = 470 (2) EXITS REQUIRED (3) PROVIDED EACH FLOOOR SECOND FLOOR 470 / 3 = 157 X 0.2 = 32" MIN. WIDTH AT EACH SECOND FLOOR EXIT FIRST FLOOR (470 + 157 + 157) 785X.02 =157" 157 < (36 + 72 + 72) OR 180° : OKAY HEAVY GAUGE WIRE "PIN ". MAIN RUNNER AT 4' -0" O.C. NORTH VERTICAL WIRE HANGER-NO. 12 GAUGE @ 4' -0" 0.0. OR NO. 10 GAUGE @ 5' -0" O.C. ALONG EACH MAIN RUNNER. - VERTICAL STRUT STABLING BAR @ 12' -0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. VERTICAL STRUT FASTENED TO MAIN RUNNER. CROSS RUNNER EXISTING B/S GYP BOARD CEILING EXISTING B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN NEW OR RELOCATED B/S 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE EXISTING 2' -0" x 4' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED /RELOCATED EXISTING B/S 2' -0" x 2' -0" RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN EXISTING B/S 1-0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO REMAIN NEW OR RELOCATED B/S 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER EXISTING 1' -0" x 4' -0" RECESSED FLUORESCENT LINEAR WALL WASHER TO BE REMOVED /RELOCATED NEW COVENTRY ARCHITECTURAL SERIES P2C PENDANT. AVIATION CABLE /COILED 10' CORD, DL12 CLEAR DOMED ACRYLIC LENS. I69- B/S SWITCH (*NEW) ▪ B/S ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN) NEW 1/32" =1' -0" NTS A S 128TH ST. N VICINITY MAP SITE PLAN (2) #10 SCREWS 5130TH 5T. REVEAL (PAINT BLACK) OR MATCH EXISTING. 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK. 122TH ST SITE 6' LIGHTING NOTES S 125T1-1 ST. 4I eat • I III I � CZ ��i�� /I � �� � 1,a l 9 I TYPICAL PARTITION BRACING NOTES: 3. PROVIDE BRACING AT ANY PERMANENTLY PARTITION THAT IS NOT ATTACHED TO CEILING GRID. 9 TH SUSPENDED CEILING. NO CHANGE TO BUILDING STRUCTURE OR USE METAL STUDS STAGGERED @ 8' -0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12-0". ATTACH TO STRUCTURE ABOVE W/ HILTI POWER DRIVEN FASTENER 3/4" MIN. CONTINUOUS CEILING GRID - DO NOT CUT. SCHEDULED PARTITION LATERAL BRACING TENANT WALLS WO CASEWORK) NTS 8' MAX MAX MAX 8' MAX,,8' MAX -1' MAX 2' MAX LATERAL BRACING PER DETAIL ABOVE (TYP.) NORTH EXISTING SITE DEVELOPMENT TO REMAIN AS IS NORTH P"N NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ABOVE TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FT. LONG. (SEE FLOOR PLAN, TI-3) REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 9y NTS NTS 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS UP TO THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 1-1/2"=V-0" 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS&A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL PROVIDE EMERGENCY PATHWAY LIGHTING OF 1 FT CANDLE @ FLOOR. 3. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. UNDER SEPARATE PERMIT 4. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 6. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 7. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 8. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 9. RE- CIRCUIT SWITCHING AS NECESSARY. ALL NEW CLASSROOMS, INCLUDING LABS, TO HAVE DUAL SWITCHES. EACH SWITCH WILL CONTROL 50% OF THE LIGHT FIXTURES IN THESE ROOMS AND BE GROUPED INTO FRONT HALF AND REAR HALF OF ROOM. SCOPE OF WORK: TENANT IMPROVEMENT TO PART OF THE FIRST AND SECOND FLOOR FOR ADMINISTRATIVE OFFICE AND TECHNICAL TRAINING USE TO INCLUDE DEMOLITION OF EXISTING PARTITIONS AND ADDITION OF NEW PARTITIONS, DOORS, RELITES, LIGHTING, OUTLETS AND FINISHES. CONSTRUCTION TYPE: Ill-B, SPRINKLERED FIRST FLOOR AREA OF SUITE: +/- 17,736 SECOND FLOOR AREA OF SUITE: +/- 14,330 OCCUPANCY: B OFFICE BUILDING CODE: WASHINGTON STATE BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL MECHANICAL 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL PLUMBING CODE 2005 NATIONAL ELECTRICAL CODE ICC /ANSI 117.1 -ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON INDOOR AIR QUALITY CODE LEGAL DESCRIPTION 7 GATEWAY CORPORATE CENTER PARCEL B OF CITY OF TUKWILA SHORT PLAT NO 89 -1 -SS RECORDING NO 8904120877 SD SHORT PLAT DAF - LOT 7 OF GATEWAY CORPORATE CENTER TAX ID NUMBER: 271600 -00- 0070 -06 SITE ADDRESS 12720 GATEWAY RIVE TUKWILA, WA 98168 PROJECT DIRECTORY: TENANT: ITT TECHNICAL INSTITUTE 13000 NORTH MERIDIAN ST CARMEL, IN 46032 CONTACT: ADAM MERKLE 317 - 706 -9316 (PHONE) 317 - 571 -0140 (FAX) DESIGNER: MARVIN STEIN AND ASSOC., LLC 2221 5TH AVE. SEATTLE, WASHINGTON 98121 CONTACT: GALEN HOLDEN 206 -441 -1449 (PHONE) 206 - 441 -4361 (FAX) EMAIL - g.holden @marvinstein.com SEPARATE PERMIT REQUIRED FOR: L(1111echanical arlElectriati L'if umbing Gas Piping City of Tukwila BUILDING DIVISION 10 GENERAL NOTES 5 PROJECT INFORMATION 5. BY L.L. @T.E. INDICATES "BY LANDLORD AT TENANT'S EXPENSE" TI -1 COVER SHEET & DETAILS TI -2 FIRST FLOOR DEMOLITION PLAN TI -2.1 SECOND FLOOR DEMOLITION PLAN TI -3 FIRST FLOOR CONSTRUCTION PLAN TI -3.1 SECOND FLOOR CONSTRUCTION PLAN TI -6 FIRST FLOOR FINISH PLAN TI -6.1 SECOND FLOOR FINISH PLAN TI -7 ELEVATIONS AND DETAILS 15 DRAWING INDEX BUILDING OWNER: RREEF 16000 CHRISTENSEN RD SUITE 101 TUKWILA, WA 98188 CONTACT: NANCY ANDERSON EMAIL: nancy.anderson @rreef.com CONTRACTOR: T.B.D. 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS FOR THIS PROJECT. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. B/S INDICATES "BUILDING STANDARD" AS PROVIDED BY LANDLORD, AS DRAWN OR SPECIFIED IN THE CONTRACT DOCUMENTS. 6. DIMENSIONS BETWEEN ELECTRICAL & TELEPHONE OUTLETS TO BE A MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 7. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS REQUIRED FOR THIS PROJECT. 8. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED FOR SEISMIC CONDITIONS, AS INDICATED HERE AND AS REQUIRED BY LOCAL JURISDICTIONS, 9. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, FIRE ALARM & SECURITY SYSTEM RENOVATIONS SHALL BE PROVIDED UNDER SEPARATE PERMITS. 10. ALL FURNITURE MOVING (INCLUDING SYSTEMS /CUBICLE FURNITURE) SHALL BE PERFORMED BY THE CONTRACTOR. GENERAL CONDITIONS PRICING SHOULD INCLUDE ALL COSTS TO HANDLE FURNITURE. 11. PAINT COSTS SHALL INCLUDE THE REMOVAL OF DRYWALL ANCHORS AND ANY PATCHING /REPAIR WORK FOR APPROXIMATELY 300 MISC. HOLES IN WALLS DUE TO ARTWORK/PROMOTIONAL WALL HANGINGS. 12. CONTRACTOR SHALL CREATE, UPDATE (WEEKLY) AND WORK WITHIN A PUBLISHED CONSTRUCTION SCHEDULE. 13. CONTRACTOR SHALL MAKE A REASONABLE EFFORT TO COMMUNICATE WITH THE DIRECTOR OF THE SCHOOL CONCERNING DAY -TO -DAY CHANGES IN THE WORK SCHEDULE, PARTICULARLY WHEN WORKING IN OCCUPIED SPACES. 14. CONTRACTOR SHALL MAINTAIN A PRACTICE OF DAILY CLEANUP, INCLUDING CONSTRUCTION DEBRIS, TOOLS, EQUIPMENT, AND MACHINERY. EXTRA CARE SHALL BE TAKEN TO CLEAN AROUND CONSTRUCTION DUMPSTERS. DUMPSTERS SHALL NOT SIT DIRECTLY ON ASPHALT OR CONCRETE, NOR SHALL THEY BE PLACED ON SOIL. PLYWOOD SHALL BE USED AS A BARRIER BETWEEN DUMPSTER BEARING POINTS AND HARD SURFACES. 15. NEW MATERIAL SHALL BE STACKED IN A 'NEAT AND ORDERLY' FASHION, AWAY FROM HIGH TRAFFIC AREAS AND OCCUPIED SPACES. 16, IF NECESSARY, CONTRACTOR SHALL PRODUCE AND MAINTAIN ON -SITE STORAGE CONTAINERS. CONSTRUCTION RELATED MATERIAL AND EQUIPMENT SHALL NOT BE STORED IN OCCUPIED ITT SPACES. FILE C Permit No. TI -4 FIRST FLOOR REFLECTED CEILING PLAN TI -4,1 SECOND FLOOR REFLECTED CEILING PLAN D py Plar review approval is subject to errs and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt 0 approved Field Copy and Tvidltions is acknowledged: Ety Date: Cit of Tukwila RI Ili DIVISION REVIEWED FOR I CODE COMPLIANCE APPROVED JUN 13 2008 ■. C' Of Tukwila BUILDING DIVISION TI - FIRST FLOOR ELECTRICAL /COMMUNICATIONS PLAN TI -5.1 SECOND FLOOR ELECTRICAL /COMMUNICATIONS PLAN NA NO. AN GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste CHECKED BY: GH, GG REVISIONS /ISSUANCE: RECEIVED 1TY OF zi IK'M'_A ERMIT CENTER TENANT: SHEET TITLE: planning 6512 RE A GEO H. .DFELLG' . S ATE OF ASHING IN • 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION ITT TECHNICAL INSTITUTE DATE: 5/6/08 11 LIGHTING LEGEND NTS 14 REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design SCALE: AS NOTED DATE 5/6/08 6/5108 0 ' - I 1 O N LTR# i COVER SHEET & DETAILS OF 12 �r• ±r. I** K B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET (T=TIMER) B/S WALL MOUNTED FOURPLEX ELECTRICAL OUTLET BIS WALL MOUNTED COMBINATION VOICE/DATA OUTLET BIS WALL MOUNTED DEDICATED VOICE LINE OUTLET B/S WALL MOUNTED JUNCTION BOX NOTE ALL OUTLETS TO BE MOUNTED 15" A.F.F. - TO BOTTOM OF OUTLET PER W.S.B.F. REQUIREMENTS U.N.O. ALL DATA & COMMUNICATION LINES TO BE ROUGH -IN ONLY (MUD RING W/ PULL WIRE) I ELECTRICAL LEGEND 0 i win B. RELOCATED B/S 20 MIN. RATED 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN B/S HOLLOW METAL FRAME. PROVIDE KICKPLATE IF NOT EXISTING. (TOUCH UP TO LIKE NEW CONDITION) • I I .aI r I I I III I I " I • E. NEW B/S 1 HOUR. RATED 3' -0" WID X 7' -0" HIGH SOLID CORE MAPLE WO DOOR IN B/S HOLLOW METAL FRAME, SMOKE SEALED. I 6" UNLESS OTHERWISE NOTED DOOR NUMBER TYPE OF DOOR A PAIR OF B/S 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN H B 0 XI IN POI' HARDWARE a. B/S LOCKSET AND CLOSER 0 T NOTES: 1. THRESHOLDS AT DOORWAYS SHALL BE z' MAXIMUM IN HEIGHT. DOOR IN B/S HOLLOW METAL FRAME (TOUCH UP TO LIKE NEW CONDITION) D. PAIR OF B/S 3' -0" WIDE X 7' -0" HIGH SOLID CORE MAPLE WOOD DOOR IN 2. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO MATCH B /S. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 3. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 5,0 POUNDS (22,2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, PROVIDE WALL STOPS (FLOOR STOPS WHERE REQUIRED) AT ALL INTERIOR DOORS. SIDE LIGHTS W/ 2" HOLLOW METAL FRAMES EQUAL SECTIONS OF GLASS SEE PLAN FOR OVERALL DIMENSIONS DOOR & HARDWARE SCHEDULE X -0" ©© L C MATCH EXISTING L Y HARDWARE NEEDS TO BE RE- KEYED) HAGER KICK PLATE MATCH EXISTING SCHEDULED BASE NTS LU 1 0 0 v E U) CD z 0 J W 0 LLJ co cD N H- 0 0 0 cll C) 0 CD J CJ U) CD J CO _ v_ U CD II Q CO (!') CO L L 0_ .. CD = I CV I I � cv C]� S E �G I lirAM — — — — ■ F = == _ — 1 -�r I I \ I � L T L I I I I I I I _! L 1 I I I I I I I I I I I T T r I I J L 1.__ J I I I ._L 1 I - --f _I I I -4 I I I I I I I I I I I I -LHE -ate ta FEC J = = = D.F. FEC U n Il I — r FHC 00 FEC[ 6 "r 6 r -S rr z "1kRI tiwri': yw, 11111 ^.III 0 LOBBY 0 5' 10' DEMOLITION NOTES: DEMOLITION KEYNOTES: r.I 1. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 3. THIS PLAN INDICATES EXISTING CONDITIONS. 4. SALVAGE ALL DOORS, FRAMES, HARDWARE AND RELITES TO BE RELOCATED. SEE CONSTRUCTION PLAN FOR LOCATIONS O DEMO ROLL -UP DOOR, TRACK AND HARDWARE ABOVE - RETURN TO OWNER Q DEMO WINDOW AND RETURN TO OWNER 0 DEMO EXISTING CEILING GRID AND TILE THIS ROOM O REMOVE EXISTING CHAIR RAIL AND WALL COVERING FIRST FLOOR PLAN NORTH 118" =1' -0" 20' 30' lisudoommowl EXISTING ONE HOUR CORRIDOR NIC NIC 'I rl inaltatin NNW 111���1111"I�dlii�l X r 10 MOM RR ANNUM M �:,lftil d>IF I1t MOM r ^^ d ,!m W* FI -- REVIEWED FOR - CODE COMPLIANCE APPROVED JUN 1 3 2003 City Of Tukwila BUILDING DIVISION GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning 6512 G RGE GOODF LOW H STAT •FWASHIiGTON sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: OH, GG DATE: 5/6/08 REVISIONS /ISSUANCE: NO. REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL A PERMIT REVISION TENANT: SHEET TITLE: ITT TECHNICAL INSTITUTE FIRST FLOOR DEMOLITION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED DATE 5/6/08 6/5/08 RECEIVED CITY OF TUKVViLA JUN 0 5 ZUU8 PERMIT CENTER TI -2 OF 12 E cn ca z 0 J W 0 w CO C—) 0 F— i 0 0 a CD CD J J CO a . o . r�F-cnox h I O n I I L ( 3 D.F. FEC 1 Q 68 WOMENS 9 NIC 0 tii I lj l r�l a ddl'' +M1' �a,P4' "all Ir rr ° l l 7a w ,14i C 1, h fiW N^ 4,71 l'C it H 1/8" =1' -0" IY Im�l� Ian , d y 4 �I+� a Rs kI t i C r: � a }' ;i. DEMOLITION NOTES: I. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 3. THIS PLAN INDICATES EXISTING CONDITIONS. 4. SALVAGE ALL DOORS, FRAMES, HARDWARE AND RELITES TO BE RELOCATED. SEE CONSTRUCTION PLAN FOR LOCATIONS. DEMOLITION NOTES: Q REMOVE VCT AS REQUIRED FOR NEW FLOOR PATH 2® REMOVE CASEWORK AND RETURN TO OWNER OR ITT ® CONTRACTOR TO VERIFY INSIDE OF STRUCTURE - DEMO IF POSSIBLE SECOND FLOOR PLAN NORTH 0 5' 10' 20' 30' isiormmuoistessimm NIC NIC NIC NIC ❑I hh LW' 141; It ill aI'I�I try la REVIEWED FOR— ORCE t CODE COMPLIANCE APPROVE JUN 1 3 X008 City Of Tukwila BUILDING PSIM. Ig_ NO. GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 Marvin Ste planning CHECKED BY: GH, GG REVISIONS /ISSUANCE: 5512 G G GEH TATE REVISIONS INDICATED THUS A REGI ER T F WA.. I.LOW III INGTON 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION TENANT: SHEET TITLE: ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design DATE: 5/6/08 SCALE: AS NOTED RECEIVED CITY 0 TUK1►irii.A JUN SECOND FLOOR DEMOLITION PLAN DATE 5/6/08 6/5/08 052008 PERMIT CENTER TI -2.1 OF 12 EET LAB 113 NEW OFFICE 112 MUL. /PTN. NEW LIBRARY 111 1 INTERVIEW NEW FAA OFFICE 109 NEW OFFICE 108 MUL. /PTN. NEW INTERVIEW 107 NEW INTERVIEW 106 INTERVIEW 105 OFFICE 104 I I HALL 138 107 B b 101 NEW CAREER SERVICES B 1 118 0 EQ. 1 : 7Av\ i_ k° HALL 141 103 STORAGE 131 STORAGE 130 SECRETARY 7 3' -0” 3' -0" INTERNET CAFE 137 C J F BOOKKEEPER II 135 INTERVIEW 134 128 129 CT COPY ROOM INTERVIEW STAFF LOUNGE FECC 0 0 REGISTRAR 133 TESTING 132 INTERVIEW 102 114 L HALL 139 � 0 0 00 MENS 00 1 119 1 OL 4 TI -7 u u II LT FEC D.F. ALIGN @ CORNER BOOKSTORE 136 F INTERVIEW L (E) 127 III U 0,1 FHC ri NEW THEORY 117 _® 1_1 [C 4 (TI-7 00( WOMENS [ no HALL 140 JANITOR L1211 7' -0" of NEW CJ LAB 115 1 'r7 : PI 1 STORAGE 122.1 THEORY ar, 7,ar 116 J ry , ^14F a; I +rl4'I;II1 41 0 I LAB 12 LAB 1241 REPS CALL CENTER 125 NEW OFFICE 126 _I LOBBY EXISTING ONE HOUR RATED 173 CONSTRUCTION NOTES: 1. CLEAN AND REPAIR BLINDS IN NEW CLASSROOMS AND OFFICES AS REQUIRED. 2. CONTRACTOR TO PROVIDE BACKING IN WALLS AT ALL WHITE BOARD AND CASEWORK LOCATIONS. 3. ONE HOUR FIRE RATED CONSTRUCTION OF CORRIDOR AND CEILING IS TO BE MAINTAINED. 4. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 5. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 6. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 7. SEE 12/TI -1 FOR WALL CONSTRUCTION LEGEND. 8. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION IS ONE HOUR CONSTRUCTION. NEW CORRIDORS TO BE BUILT TO MATCH. CONSTRUCTION KEYNOTES: O CONTRACTOR TO PROVIDE AND INSTALL POLYVISION 100 SERIES 4' X8' M1140 -084 WHITE BOARDS WITH NARROW PROFILE EXTRUDED ALUMINUM TRIM PEN /MARKER TRAY WITH RADIUS SAFETY CORNERS. VERIFY LOCATION WITH TENANT. O CONTRACTOR TO PROVIDE 1" X 6" WIDE SOLID POPULAR (PAINT GRADE) CHAIR RAIL WITH ROUNDED CORNERS. WOOD TO BE MOUNTED WITH SCREWS, PLUGGED AT SCREW HOLE, AND SANDED SMOOTH. INSTALL AT 34" TO THE TOP WHERE INDICATED. REPAIR / REPLACE WHERE NEEDED. SEE FINISH SCHEDULE FOR PAINT COLORS. O EXTEND WALLS TO STRUCTURE ABOVE. CONTRACTOR TO INCLUDE COST FOR FRAMING, SHEET ROCK AND FINISHING - ACHIEVING A SMOOTH WALL LOOK. PROVIDE FIRE DAMPERS ON ALL PENETRATIONS THROUGH THE WALLS.. 40 MODIFY SPRINKLERS THOUGH OUT INTERNET CAFE AS REQUIRED. O REMOVED PORTION OF EXISTING CHAIR RAIL. PATCH AND REPAIR WALL. FIRST FLOOR PLAN NORTH 1/8" =1' -0" 0 5' 10' � wry, ti °� � Mr an a��1�1 . "4.P,� +.�x�l sFhi- n4r�.: •` rrn��exnyj i I I 20' 30' N.I.C. EXISTING ONE HOUR RATED CORRIDOR N.I.C. p�?7� ml�,r p Prq ir .u ` 1'1 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 3 2008 4 City Of Tukwila BUILDING DIVISION NO. .7\ GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 Marvin Ste planning TENANT: sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION SHEET TITLE: REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. SCALE: AS NOTED ITT TECHNICAL INSTITUTE FIRST FLOOR CONSTRUCTION PLAN TI -3 OF 12 U- C Cl_ (z C r U- 1--- THEORY 202 STUDY GROUP I 203 I THEORY 207 LAB 208 LAB 209 EQUIPMENT ROOM 210 THEORY 211 5J. O on Cr) N STUDY GROUP 204 1 HALL 225 _I THEORY 206 STUDY GROUP 205 OIL. INTERVIEW 223 D.F. FHC FEC FEC HALL 224 (E) L, C5 b TI -7 N.I.C. !II II hIIVIlil W'adtlWJr4kr Ia, IL i3 u�. p+! r. 20'-2" (2 r-- 212 INSTRUCTORS OFFICE AREA 0 I3IL1I Ik_r I "III 11.5 �aa�w w,w, L� wa1 f AV 'u Al<'V. 1 Ian u Aga do nti d. LOBBY EXISTING ONE HOUR RATED NEW THEORY 216 EET LAB 215 EET LAB 214 NEW COMPUTER LAB 213 1/8"=1 CONSTRUCTION NOTES: 1. CLEAN AND REPAIR BLINDS IN NEW CLASSROOMS AND OFFICES AS REQUIRED. 2. CONTRACTOR TO PROVIDE BACKING IN WALLS AT ALL WHITE BOARD AND CASEWORK LOCATIONS. 3. ONE HOUR FIRE RATED CONSTRUCTION OF CORRIDOR AND CEILING IS TO BE MAINTAINED. 4. ALL WALL INFILLS TO ALIGN WITH ADJACENT SURFACES ON EACH SIDE. 5. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 6. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. 7. SEE 12/TI -1 FOR WALL CONSTRUCTION LEGEND. 8. EXISTING CORRIDOR WALL CONSTRUCTION SIMILAR TO STANDARD TENANT SOUND PARTITION IS ONE HOUR CONSTRUCTION. NEW CORRIDORS TO BE BUILT TO MATCH. CONSTRUCTION KEYNOTES: 0 CONTRACTOR TO PROVIDE AND INSTALL POLYVISION 100 SERIES 4' X8' M1140 -084 WHITE BOARDS WITH NARROW PROFILE EXTRUDED ALUMINUM TRIM PEN /MARKER TRAY WITH RADIUS SAFETY CORNERS. VERIFY LOCATION WITH TENANT. O 2 CONTRACTOR TO PROVIDE 1" X 6" WIDE SOLID POPULAR (PAINT GRADE) CHAIR RAIL WITH ROUNDED CORNERS. WOOD TO BE MOUNTED WITH SCREWS, PLUGGED AT SCREW HOLE, AND SANDED SMOOTH. INSTALL AT 34" TO THE TOP WHERE INDICATED. REPAIR / REPLACE WHERE NEEDED. SEE FINISH PLAN FOR PAINT COLORS. SECOND FLOOR PLAN NORTH 0 5' 10' 20' 30' J N.I.C. N.I.C. EXISTING ONE HOUR RATED CORRIDOR J N.I.C. N.I.C. n�1 t 1'14111: 1. : : r =� — REVIEWEb FOR-1 CODE COMPLIANCE A OVE JUN 1 3 200B City Of Tukwila BUILDING CSC NO. GATEWAY CORPORATE CENTER BUILDING #7 Marvin Ste CHECKED BY: GH, GG REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A PERMIT REVISION TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TU K WI LA, WA 98168 6512 planning ra GEORGE H. 00FELL iW 71111 ATE O WASHI '+ /ON ISSUED FOR PERMIT AND APPROVAL :sociates, tic design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441-1449 DRAWN BY: TS JOB NO.: 08028 -000 ITT TECHNICAL INSTITUTE DATE: 5/6/08 SCALE: AS NOTED DATE RFpEIVED CITY OF TUKWILA JUN PERMIT CENTER SECOND FLOOR CONSTRUCTION PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. 5/6/08 6/5/08 0 5 2008 TI -3.1 OF 12 L H L Lil w CORPORATE E U I L 12720 GATEWAY TU K WI LA, ', 1 e.- 4GE TE r+ ` CENT ER I #7 DRIVE WA 98168 --, . R IT-;:. , - WA NGTON 114 ® 116 II � J L xd' II 7 F y : I�. .., G I lk • j g _'. C, r. �r ( rrrr 4 G r y� l � .ie I. ■ ■/� .1w .✓� • 4'"fe.,�i:'a I ' MI uC > .. �'.. c F�i'I' AMI■M.wl. ill ��� 4 ? .4,. ..; 'I 1TMf �'�:,C� I _, ... _ _ __ ___ __ r r .... .... ...M■IA■MM.N1 ■ I immm� 1 ® / m A W al . I =■ II 1 P� r r I�M/= / / = ' 1II WA= / q IM= M= M1 .1 =® or IIIL , / . �� / / EM I II IMII ■� = -' �� _ �I III- �I ® I�r• I_ /mom `� / md 1111/2Abl V �� � / I Ir�.■...s�■r.■� ir,„ v-41 / �� / ! I�� �i I ,� -- I7 � �� 7 1 • + I I�\ iir I / /,'' F EMME" ®�li / / jr I A rI / 1 i�IJ �� =i� - / L .' ml / / rLa � •�•�� / / ®I� 1/11111 i =t /I = / � �. � � ��III 1 / i IMMI I / / / / L/ m I �� V FE 112 � ® I i ■ i �Frir� ' �' / IN ln r 1 ,A��O / El . / ® /. TIMM I i��___�„Il 1..!�M / f '1 I I � 1 L II 'I (I � ",;,��I,Iv� °Ir�'r u��;If B , h G I ,,��, � �� "�'��' 4 I rl � I � +- • ®/ / 111 I /____ ■1� ■MENE EE. � � , .r.�, ; '" � � / / 118 / , S 1 u r 3 " � �. I =is gm, ���1 EMI. a .1 III ■ ova �'.�� / � .. ,./ IM���� ■� I®/ 1 .■ =VA 7 41/MIKEVAIIIIMMik � �I L. .. �I. �r P ...,.�.�l�rrr...51■■1■■w•1■■AI� 1•11111111/111.11 / / / I ' ll� '+ —, . - - • , • . 119 1 ���� / - ..- : -•. • - 20 • , _ _ :• .. - -- ,s I hK I 'I. V °, .:' .�, " �I r .: � 1° r � � } a 1 d w�, .,k�L I `' a � ���V r, w ���� rrr. rrrr :. . .. • .. • _ - , ���� rrrr� ■■n i; rrrr rrrr ■ ■ MO ■ ■ •••01 rrrr rrrr MI ■ ■ TEN = ■ ■, ■■� ■ ■ i i i��,:..� I P I p r ,, 1 a, ° M,i l I I " I ' G, 7 r" � ; lq7 r k }` "'ry.. "I r I I CS p ; , k l " r I " „�a fir:” e i: I $ �i' OME � yyR�"lu fp l ti " �' ri d', fg 44s Iti.l' �c P : ,.:� a '„ '- i .. _ _.. - . .�, - -- fu, y" . , s,° X4 11 , raw. ° �u • w d �' " � p Ia !NII' � + s�° F, �', J I'''vll ..I I !�� •� '. n',WI.iPI"'JI 4,. ry '.r I �z ,R, rrrr z ?I'I r x y" + ha r r) � v a ;' I 9 I :. "� ' /' / rrrr WM 1 � . � 9 a, �r � a � " �, I �� s ■ rrrr rrrr ■■. ..: ■ ■■r V . I�i��; �L d° r• �) r, �1 "` rrrr rrrr ," I ! ■ ■ ■■ MI u I I,, ht_ h I y mI. ql ' I �4i 1 d, ) I 9Ha IIu'tl ¢,�"r.� •y + y SQ , v �IW '��I �I . +'.5 g ✓� I d': FILL / / / / MB — • _ WI ,9 Y.� a� Vi : S ilk . .,........_ �'I', rrrr ■■o ti: p c I :iNr u o I ,I,,�x� II °.. P I u C S v ,MEN + d Vpl ' ,) a l0 , � k, ; _ ...�V '3� : :: „ a I p / = • EMI rrrr rrrr WM • ■ ■ ■. Ord ,'', t7 - 4 „ r �'�G""� ? V MI NIM rrr: II "� I h ov J ll l N. �. w Y �r I q I ' . .r ;I _ ..._ . _ . ■■■ 11 111 4I:� II °wI .`a p N � �� �, `� I. n � 9 , 7 dm r L,� -- - -- -- - � I W � ^aF'.', .. I,p w1R" a W.,V r, t I',IIIIIIIrn bl {d I I I I u5 V Il I , " Vs 1, }r �V f V I� J � ..dfl ( fin LOBBY I� 1 � Ix � , P T o ABOVE A p — � �m,.r zy VY6EI ' . '' - y ii Irr. MI Mil � a� 1� 'uf4 m, ".; 'qty � ) ,�,• 1 1 ��l !� d e0 ! V �J,.• 0 .r ri L,. 11 wti�r'f,l 4 14 j1 n ` , y .:. MI •, � . a`.� rtl'I r. �� A"�. ` "j S.., 1 � 1 1. J _ ' I F — ru :: 1 y'I 1 F I ' ` , 4 u , I ti tl Ir I "4 4. g . ^ 91 ro " ,4 11 I r r q!,+ N "I,) / y / / I 1 M ,?' / ,4a / „I k' 1 ._. � I k .. '" ,,w " 'gi " eI`: .. , 1, • :, y ' ;::'Y. '” , ' , a,. ;:.r �� 1 n! d , ,' a IIr f v ,7ti a• I,,w a ryZ•„ �y :'y:. " m +•y. I s .._ . .. I 1 71 •. I Ivu1 +� V id':.r, mn 4y I ,I rs`Ntia ilk f' : J : r? r , a 4 J, 14 ' I I II _.. el, ,,.• M II ” PI I 4 ^11 ' "+r' I yl ' �' p a p � ��; a y ti a l I d . N , . ' ", t / .... .. � �. ` f � � k ' �iq�.��yl �� 1p ;w �r `� �,.yr IY.:r 9" " II e / / T .r �' V.�`..S I rY„ O / // _ .. H -i l I 4 ���k ,,I . a ° 9 ' II � I aII m I I H I 1rko Yr r 1 R f _ —, ,; __ __- 1 ■ .. 1 E. � ® � 122 4 138 ...� �� IF ! -� I�Iu, i� — — 1. -- \I I I OPEN _.. r I T () —; I -- -- ABOVE; J Ji 1 EH=F: ,L I I I 7 .+ q I� y�s'� �J w4trau r ..x...11..... ..m..0.1.0 I MN I I L137 -- to T 1 r 123 ��. r f J i g. ■I -, irk ,, c. ■_ I , - - STRUCTURE Ali rrrr r ■•••••111 I ■■ ■rrrr ■r ■r■ ik ANICII J IL . I —1 I I I_ „"c II _ it i1,:',Nz � �. _ t I n ` Marvin Ste sociates, LLC = planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 T -10.. 109 El ui - - - - - -- i ij j U - 1 �_ �_ - - -- _I ONE HOUR RATED SUSPENDED CEILIN SYSTEM ALTERATIONS TO PANEL AND c LIGHTING FIXTURES PER RATED CEILING SYSTEMS MANUFACTURES REQUIREMENTS - I I I-_-1 I - II I I 13 Eli _ _ _ ■ II I I I III II I 134 ill 124 DRAWN BY: T$ JOB NO.: 08028 000 '• I � ME 108 I I f _ T l� - CHECKED BY: GH, GG DATE: 5/6/08 II I I - _ � — ■I 141 I _ < SCALE: AS NOTED REVISIONS /ISSUANCE: I� I�v r ��—� - -- - 1� CODE COMPLIANCE Ap ROVED t JUN 13 2008 LIGHTING CALCULATIONS. NO, REVISIONS INDICATED THUS n DATE 1- 1.11 NM IM d i I I_ ISSUED FOR PERMIT AND APPROVAL 5/6/08 I 133 I11 A PERMIT REVISION 6/5/08 I ' :. -- - - -- -- - il 1 :i ii � - -- I - -- ■ - - I M �1! — II �■ - I , ∎ 111 �mI �I Of Tukwila EXIS TING LAYOUT: - -- — - - 1 I r � � BUILDING 1150i (3) 2X2 RECESSED FLOURESCENT FXTURES ( 10 ) 1X4 RECESSED FLOURESCENT FIXTURES (17) RECESSED FLOURECSET =1 I m w0- I . I I I, I � I �I- �' I _._..._ . I I_ _ _ I -I I I- I • " ; Mill —III �I © _ C1 I I I ❑ -- � ,— ■I 131 132 22,054 WATTS PROPOSED LAYOUT: ■ . I -1 NI-I-_I S-I—_ 42 I • -. -_ -- ■.I■ 125 (223) 2X4 RECESSED FLOURESCENT FXTURES i M �� - � II _ S` I (9) RECESSED FLOURESCENT FIXTURES (17) RECESSED FLOURECSENT DOWN LIGHT ( ) ( 8) SUSPENDED PENDANT FIXTURE 107 RECEIVED - � � I li ;;;; L. I �I CIS ° i UKl�LA I WWI MEM rrrr _. - - - - -- = 22,472 WATTS SUMMARY: JUN Z008 I 1 µ "��::i:;� ill ',_ ■ ■ ■r I .r■r , rir�ir■�......i MI ■ ■ 1A■I I ■ ■ ■ ■Iw�� L _ . 130 PERMIT CENTER r�l ■ I CENTER THE EXISTING LAYOUT HAS ATOTAL OF (22,554) WATTS. THE PROPOSED LAYOUT HAS A TOTAL OF (22,472) WATTS. NO WATTAGE IS ADDED: OKAY —� I. . ... -- r r - -_ MI y _ �.0 . J I ___■ � 1 1 I I _ III ill 126 TENANT: ITT TECHNICAL INSTITUTE � � � �r rri REFLECTED CEILING NOTES: _ 0' :. •: �• : - � 106 I i�� M� : ' n _, I 1_I _ y , � _ 1 _- _ _ , r 1. SEE 14/TI-1 FOR LIGHTING NOTES 1 II MI n, . 129 , , ll r ■ • 2 . SEE 8/TI -1 FOR SUSPENDED CEILING BRACING O r y I � X1 ■�.. � �� I "" I 3. ADJUST EXISTING ACOUSTICAL TILE CEILING AS SHOWN ti� •.., 1 I-__1;I ■-I I .I, ^_ 0 • 0: 4. THE EMERGENCY PATHWAY LIGHTING THAT EXISTS MUST BE MAINTAINED PER CODE, NEW AREAS OF WORK MUST ALSO COMPLY, : .: .: '. •. .. - " ` & THE ACTUAL EMERGENCY PATHWAY LIGHTING LOCATIONS NEED : :, -. v TO BE DEPICTED ON THE ELECTRICAL ENGINEERS PLANS. / '. O. 1 " •' I ��' __.. . � 105 I MG I III ` ,, , liI I I■wil 1 128 ... ' _ " , , • ; Q : • REFLECTED CEILING KEYNOTES: II_ �� • ii SHEET TITLE: FIRST FLOOR REFLECTED CEILING PLAN I-_i.■.II— I l•�li 0 . -.. - : 0 DEMO EXISTING CEILING GRID AND TILE THIS ROOM. MP , ii . 2 RE- CIRCUIT SWITCHES TO ACCOMIDATE NEW LIGHTING LAYOUT. •. . a III■ 1 _ .. 104 I t -__II = —— ....,....- 1 :i r ...w � __II ill FM : .':: ; 100 II - -, FIRST FLOOR PLAN NORTH _II �I - • ■_ 103 102 101 —i 0 r � I_ ■�� ��_---_ _ _ i ____ _ - II I e 0 5' 10' 20' 30' REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. T1.4 OF 12 Lil w I J U 217 II Jr LOBBY lag °�' lfrI I e I I L -- J : ■::� i■■■■I■ ...III 11111...111 1.11 11111 i! � I MI 111 111111111110.0 1 .0 II I I I 1 11111111 III I I II ••••••••••••••••I •4 I 223 I I I py/ ► 1 �r 1 MaTEll Icy CN 1 203 207 210 212 12161 1/8" =1 -0" LIGHTING CALCULATIONS: EXISTING LAYOUT: PROPOSED LAYOUT: (221) 2X4 RECESSED FLOURESCENT FXTURES (6) 1X4 RECESSED FLOURESCENT FIXTURES TOTAL = 21,408 WATTS (215) 2X4 RECESSED FLOURESCENT FXTURES (11) 1X4 RECESSED FLOURESCENT FIXTURES TOTAL = 20,992 WATTS SUMMARY: THE EXISTING LAYOUT HAS A TOTAL OF (21,408) WATTS. THE PROPOSED LAYOUT HAS A TOTAL OF (20,992) WATTS. NO WATTAGE IS ADDED: OKAY REFLECTED CEILING NOTES: 1. SEE 14IT1 -1 FOR LIGHTING NOTES 2. SEE 8ITI -1 FOR SUSPENDED CEILING BRACING 3. ADJUST EXISTING ACOUSTICAL TILE CEILING AS SHOWN 4. THE EMERGENCY PATHWAY LIGHTING THAT EXISTS MUST BE MAINTAINED PER CODE, NEW AREAS OF WORK MUST ALSO COMPLY, & THE ACTUAL EMERGENCY PATHWAY LIGHTING LOCATIONS NEED TO BE DEPICTED ON THE ELECTRICAL ENGINEERS PLANS. LIGHTING KEYNOTES: O RE- CIRCUIT SWITCHES TO ACCOMIDATE NEW LIGHTING LAYOUT. SECOND FLOOR PLAN NORTH 0 5' 10' 20' 30' MEANS OF EGRESS ILLUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. IBC 1006.2 Illumination level. The means of egress illumination level shall not be Tess than 1 foot - candle at the walking level. IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior Iandings...for exit discharge doorways... REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 3 NOB City Of Tukwila BUILDING DINSION J NO GATEWAY CORPORATE CENTER BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 4441-e- GEO E GO EH. STATE OF WASH FiEG ., A5} F' / Marvin Stekk`isociates, LLC planning design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GH, GG DATE: 5/6/08 REVISIONS /ISSUANCE: REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION TENANT: SHEET TITLE: ITT TECHNICAL INSTITUTE REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY M5 &A 2008. SCALE: AS NOTED RF,ICEVED CITY OPF TUKW1LA JUN DATE 5/6/08 6/5/08 0 5 Z008 PERMIT CENTER SECOND FLOOR REFLECTED CEILING PLAN TI -4.1 OF 12 ..... ..... LOBBY '1414 ELECTRICAL NOTES: 1. EXISTING ELECTRICAL NOT SHOWN 2. SEE 11/TI -1 FOR ELECTRICAL I COMMUNICATIONS LEGEND 3. SEE 1 -TI-4 FOR LIGHT SWITCHES ELECTRICAL KEYNOTES: FIRST FLOOR PLAN NORTH 1/8" = 1' -0" a CONTRACTOR TO PROVIDE (1) ELECTRICAL OUTLET 7" BELOW THE CEILING AND CENTERED OVER WHITE BOARDS TO ACCOMMODATE (1) CLOCK - MODEL: GRAINGER #5H352, 9" ROUND. J UN 13 X008 GATEWAY CORPORATE CENTER BUILDING #7 REVISIONS /ISSUANCE: PERMIT REVISION TENANT: 12720 GATEWAY DRIVE TU K WI L A, WA 98168 Marvin Ste planning CHECKED BY: GH, GG NO. REVISIONS INDICATED THUS A REGIS ED ISSUED FOR PERMIT AND APPROVAL ITT TECHNICAL INSTITUTE sociates, tic design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 DATE: 5/6/08 SCALE: AS NOTED 5/6/08 SHEET TITLE: FIRST FLOOR ELECTRICAL / COMMUNICATIONS PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW- COPYRIGHT BY MS &A 2008. TI -5 OF 12 I— Q LAL.rfrRqr r rg ail I °fr 1 "Iu ° iiii s ^I'I1 =9 1 9'I AMC Haig Att k ilit ", . W a 0 LOBBY 4, u GATEWAY CORPORATE CENTER BUILDING #7 Marvin Ste REVISIONS /ISSUANCE: TENANT: 12720 GATEWAY DRIVE TUKWILA, WA 98168 REVISIONS INDICATED THUS A design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: GM, GG DATE: 5/6108 ITT TECHNICAL INSTITUTE sociates, tic SCALE: AS NOTED ISSUED FOR PERMIT AND APPROVAL 5/6/08 PERMIT REVISION 6/5/08 PERMIT CENTER 203 1 F211 luad"Il ula 223 FEC IFEC FHC 224 F 216 H 215 ( 2131 SECOND FLOOR PLAN NORTH 1/8" =1' -0" Q CONTRACTOR TO PROVIDE (1) ELECTRICAL OUTLET 7" BELOW THE CEILING AND CENTERED OVER WHITE BOARDS TO ACCOMMODATE (1) CLOCK - MODEL: GRAINGER #5H352, 9" ROUND. 0 5' 10' ELECTRICAL NOTES: ELECTRICAL KEYNOTES: 1. EXISTING ELECTRICAL NOT SHOWN 2. SEE 11/TI -1 FOR ELECTRICAL / COMMUNICATIONS LEGEND 3. SEE 1 -TI-4 FOR LIGHT SWITCHES 20' 30' C O M P L I A N C E REVIEWED FOR WNW_ __ SHEET TITLE: SECOND FLOOR ELECTRICAL / COMMUNICATIONS PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS&A 2008. TI51 OF 12 L H- C FINISH SCHEDULE SYMBOLINO. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL NA NA NA NA SIZE NA 12" X 12" 12" X 12" 12" X 12" 12" X 12" CONTACT CONTACT NOTES GLUE DOWN GENERAL CARPET PATCRAFT SPLASH 10060 60605 SWAN DIVE 52143 BILL COTHRAN 1-800-713-6697 EXT. 5225 FOR NATIONAL ACCT. INFO CPT -1 VINYL COMPOSITION TILE ARMSTRONG STONE TEX SCOTT MAHER 1-800-356-9301 EXT. 8962 FOR NATIONAL ACCT. INFO SCOTT MAHER 1- 800- 356.9301 8962 FOR NATIONAL ACCT. INFO NA VCT -1 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52139 NA VCT -2 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52155 XT. SCOTT MAHER 1 -800- 356 -9301 E 8962 FOR NATIONAL ACCT. INFO SCOTT MAHER 1-800-356-9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA I VCT 3 I VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52153 NA NA NA VCT -4 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52127 NA 12" X 12" NA SCOTT MAHER 1- 800- 356 -9301 EXT. 8962 FOR NATIONAL ACCT. INFO I VCT -5 I 0 GENERAL PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #1165 ITT SUBTLE SAGE NA MIKE MANETTA 317- 870 -0351 EXT. 611 FOR NATIONAL ACCT. INFO NA (1) CHAIR RAIL PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1159 ITT CITYLINE NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO ALL AREA EXCEPT CJ LAB 0 CHAIR RAIL PAINT I CEILING PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #11007 ITT BLACK TIE NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL IN CJ LAB CP WHITE BOARD TRIM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1217 ITT BLUE BLAZER NA 12" WIDE BOARDER MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 ACCENT PAINT PITT SBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #6165 ITT CONNECTED GREY NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA CD ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #212 -6 ITT YARROW NA NA MIKE MANETTA 317 - 870 -0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1158 ITT OYSTER WHITE/ SATIN FINISH NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA w 0 RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1900 ITT LIMINOUS WHITE! FLAT FINISH NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 4113) WALL COVERING D. L . COUCH 2DLC20 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 -433 -0790 FOR NATIONAL ACCT. INFO WALLS BELOW CHAIR RAIL IN STUDENT CORRIDOR 0 WALL COVERING D. L . COUCH 2DLCO9 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 - 433 -0790 FOR NATIONAL ACCT. INFO LOBBY WALLS RUBBER BASE ARMSTRONG NA 06 OLIVINE NA 4" NA ALL AREA EXCEPT CJ LAB B -1 RUBBER BASE ARMSTRONG NA 60 JET BLACK NA 4" NA CJ LAB CO . SOLID SURFACING CORIAN PRAIRIE (E) NA NA NA NA NA PL -1 PLASTIC LAMINATE WILSONART D478 -60 AMAZON NA NA NA NA 0 a) E o_ H O — C CO Q)— o 1 ,l E� CD 1 o Q- - `•2 II Li_ � 0' i 3_ - 5 tE p0 ) nI-cnn� 106 II 103 129 128 127 FEE :. iii.. .... ■u••i•■.■.■ IIIIMEIBMIEMEMEMEME D.F. FEC n FHC 101 1 117 CPT -1 B -1 140 [ . FEC 115 El I= = =rru■�. CPT -1 1 00 D.F. II 122 � II�ml(m�' 1 1�, Vlkii ��hh p yea go Ili � MEN 116 0 123 125 LOBBY 0 5' 10' rLr1.r�.J FINISH NOTES: FINISH KEYNOTES: FIRST FLOOR PLAN NORTH 1l8" =1' -0" 0 ALL MATERIAL ON DECK TO BE PAINTED P -3 INCLUDING ELECTRICAL, DUCTWORK, SPRINKLER PIPES, ETC. O SEE ELEVATION 5/TI-7 FOR EXACT LOCATION O 3 PATCH AND REPAIR WALL AS REQUIRED 0 EXACT PAINTS AND LOCATION IN THIS ROOM TO BE VERIFIED 20' 30' imeasrmanuntemouJ 1. PATCH AND REPAIR ALL FLOORING AND BASE AS REQUIRED. 2. PROVIDE FINISH SUBMITTALS FOR VERIFICATION THAT MATERIALS ARE STILL IN PRODUCTION AND THAT THEY MATCH EXISTING. E l VCT -1 VCT -2 • VCT -3 ® VCT-4 .r FLOORING LEGEND 'I1 "AN Waal a 11i11'e'>.ai. MINH V6�1� "11 uidl'llil' I Jai1 2i00114149, Ir* FOR' CODE CO MP A � APPRO 1�1i .10 211 I CM Of Ilk& NO n GATEWAY CORPORATE CENTE BUILDING #7 REVISIONS /ISSUANCE: PERMIT REVISION TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TU K WI LA, WA 98168 Marvin Ste planning REVISIONS INDICATED THUS A ISSUED FOR PERMIT AND APPROVAL 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 CHECKED BY: CH, CC DATE: 5/6/08 ITT TECHNICAL INSTITUTE FIRST FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design SCALE: AS NOTED DATE 5/6/08 6/5/08 RECEIVED JUN U 5 2008 PERMIT CENTER OF 12 TI -6 FINISH SCHEDULE SYMBOUNO. DESCRIPTION MANUFACTURE STYLE COLOR/FINISH MODEL SIZE CONTACT NOTES GENERAL CARPET PATCRAFT SPLASH 10060 60605 SWAN DIVE NA NA BILL COTHRAN 1-800-713-6697 EXT. 5225 FOR NATIONAL ACCT. INFO GLUE DOWN CPT -1 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52143 NA 12" X 12" SCOTT MAHER 1-800-356-9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA VCT -1 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52139 NA 12" X 12" SCOTT MAHER 1-800-356-9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA VCT -2 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52155 NA 12" X 12" SCOTT MAHER 1- 800 -356 -9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA VCT-3 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52153 NA 12" X 12" SCOTT MAHER 1-800-356-9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA VCT-4 VINYL COMPOSITION TILE ARMSTRONG STONE TEX 52127 NA 12" X 12" SCOTT MAHER 1- 800- 356 -9301 EXT. 8962 FOR NATIONAL ACCT. INFO NA r VCT-5 I 0 GENERAL PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #1165 ITT SUBTLE SAGE NA NA MIKE MANETTA 317 -870 -0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 CHAIR RAIL PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI -GLOSS #1159 ITT CITYLINE NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO ALL AREA EXCEPT CJ LAB 0 CHAIR RAIL PAINT / CEILING PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #11007 ITT BLACK TIE NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO CHAIR RAIL IN CJ LAB 0 WHITE BOARD TRIM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1217 ITT BLUE BLAZER NA 12" WIDE BOARDER MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #6165 ITT CONNECTED GREY NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA CD ACCENT PAINT PITTSBURG PAINT SPEEDHIDE INTERIOR EGGSHELL #212 -6 ITT YARROW NA NA MIKE MANETTA 317 - 870 -0351 EXT. 611 FOR NATIONAL ACCT. INFO NA ea RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1158 ITT OYSTER WHITE! SATIN FINISH NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 RESTROOM PAINT PITTSBURG PAINT PURE PERFORMANCE INTERIOR SEMI GLOSS #1900 ITT LIMINOUS WHITE/ FLAT FINISH NA NA MIKE MANETTA 317-870-0351 EXT. 611 FOR NATIONAL ACCT. INFO NA 0 WALL COVERING D. L . COUCH 2DLC20 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 -433 -0790 FOR NATIONAL ACCT. INFO WALLS BELOW CHAIR RAIL IN STUDENT CORRIDOR 0 WALL COVERING D. L . COUCH 2DLCO9 NA NA 20oz, TYPE II, 54" WIDE SHANNON WEIRICK 800 -433 -0790 FOR NATIONAL ACCT. INFO LOBBY WALLS RUBBER BASE ARMSTRONG NA 06 OLIVINE NA 4" NA ALL AREA EXCEPT CJ LAB B -1 RUBBER BASE ARMSTRONG NA 60 JET BLACK NA 4" NA CJ LAB CM 0 SOLID SURFACING CORIAN PRAIRIE (E) NA NA NA NA NA PL -1 PLASTIC LAMINATE WILSONART D478 -60 AMAZON NA NA NA NA N z U- 0 cn a) 202 12031 207 H 208 1 209 1 210 211 1 2041 12251 D.F. 219 220 1 j ib, Ii'li 1 • 22 FEC 224 IQ 88 irr I 200 I 0 0 r^1 I r^1 I r'1 ti I CPT -1 1 B - 1 CPT -1 (B " k � dM1 i p�. . . 0 i 7 12 ) H 216 215 1 214 LOBBY 213 1/8"-i-0" In FINISH NOTES: FINISH KEYNOTES: 5 1. PATCH AND REPAIR ALL FLOORING AND BASE AS REQUIRED. 2. PROVIDE FINISH SUBMITTALS FOR VERIFICATION THAT MATERIALS ARE STILL IN PRODUCTION AND THAT THEY MATCH EXISTING. 0 PAINT WALL WHERE REQUIRED IN ADJACENT SUITE O PAINT TO MATCH EXISTING LOBBY FINISH SECOND FLOOR PLAN NORTH 0 5' 10' 20' I mintlennumenszensi fiK Vt 'k, 30' J J I❑ ,1141 *I1ili'r a 4i i Oki @ I'flll'1, It Iltc IE ED FOR -1 ` APP (NED BUILDING VSiQL NO. GATEWAY CORPORATE CENTER BUILDING #7 TENANT: SHEET TITLE: 12720 GATEWAY DRIVE TUKWILA, WA 98168 Marvin Ste planning CHECKED BY: GH. GC REVISIONS /ISSUANCE: REVISIONS INDICATED THUS 0 ISSUED FOR PERMIT AND APPROVAL PERMIT REVISION sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 DRAWN BY: TS JOB NO.: 08028 -000 ITT TECHNICAL INSTITUTE SECOND FLOOR FINISH PLAN REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. DATE: 5/6/08 SCALE: AS NOTED RECEI CITY OF 1-6. 0 E 0 CD z CD J W a O W tz co N H- O C) A N 4 J I Ca in C) J c7 V1 U- a C C C� ll cr , AY CORPORATE CENTE BUILDING #7 12720 GATEWAY DRIVE TU K WI LA, WA 98168 6512 G k r4.1r LOW HI STATE •• wzs- IINGTON 'c Cr — 9T CLO - G #5H3 INSTALL TOP OF OUTLET @ 7 "BELOW CEILING GR ID, AND CENTERED ON WHITE BOARD 9 CLOC - GRAGER #5H352 IN STALL K TOP OF N OUTLET @ 7" BELOW CEILING GRID, AND CENTERED ON WHITE BOARD t \ \ oLIGN \ _... METAL STDS. AND GLASS SHELVES TO MATCH EXISTING \ a \ 1' -0„ — — — „ PAINT 3 BEYOND WHITE BOARD -- WHITE BOARDS 1 — — — PAINT 3" BEYOND WHITE BOARD — 12" BAND OF SEMI -GLOSS (P-4) 1-0" // 1' -0" 12" BAND OF SEMI -GLOSS (P-4) PAINT AROUND TOP AND SIDES OF WHITE BOARD. O ! PAINT AROUND TOP AND SIDES OF WHITE BOARD. PAINT 3" BEYOND WHITE BOARD - WHITE BOARD�� , - - WHITE BOARD --f / / , / . \ \ CHAIR RAIL SEE FINISH SCHEDULE . FOR PAINT COLOR CHAIR RAIL SEE FINISH SCHEDULE _ FOR PAINT COLOR N DOORS W/ LOCK EXIST. DISPLAY CASE VERIFY NUMBER OF WHITE BOARDS FOR EACH ROOM I ANGLED WALL I •I 1 SINGLE WHITE BOARD ELEVATION 1/2 =1 -0 2 DOUBLE WHITE BOARD ELEVATION 1/2 =1 -0 3 LOBBY DISPAY CASE 1/2 =1 -0 c ail 7 EXIST. LIGHT SOFFIT / TI -7 EXIST. MIRROR NEW COUNTER TOP SS -1 PROVIDE SUPPORTS AS REQUIRED PL EQ TOP OF STRUCTURE -2 P -5 P -5 EQ -1 A r g x o, ¢ m \ \ I l T 7T I I ti -----' r L ill _.-F i P R \/1 P -1 PAINT INSIDE WALL AND TOP OF SOFFIT P -5, TYP. SCHEDULED EQUIPMENT P -1 VARIES O 4 � 1/2 " =1' -0" � — — — — — ---- r -- — ----1 i — 1 __- ____ ---. — —I I P -5 � — I I — I I - _ I P_5 R C C''r D O OM COUNTER -5 II \t / \\ EXISTING — - — — DECKING } SUPPORTS AS REQUIRED GWB PAINT P SYMBOL/NO. MANUF. ZURN STYLE DESCRIPTION d r SCHEDULED BASE E -1 26916 NA AQUASENSE "A" BATTERY POWERED LAVATORY FAUCET. VANDAL RESISTANT AERATOR VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT .. Marvin Sty & ;,sociates, LLC planning design g 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 - 1449 F '1 F � VERIFY VENDING EQUIPMENT LOCATIONS W/ TENANT EQ - 2 CORIAN CORIAN INTEGRAL SINK - GLACIER WHITE, 4" CENTERS, COLORS WHITE, 1 1W TRAP. - - 6 ; A L I� te, \ , _ . „ . .... GWB - PAINT P -6 VARIFY WITH EQUIMENT X O 5 1 INTERNET CAFE VENDING ELEVATION 1/2 " =1' -0" 7 VENDING SOFFIT DETAIL 1 " =1' -o» 8 EQUIPMENT SCHEDULE NA DRAWN BY JM JOB NO 08028 -000 REVIEWED CODE COMPLIANLE JUN �; ���+ila BUILDING . ITS O _ CHECKED BY GH, GG DATE: 5/6/08 SCALE: AS NOTED REVISIONS /ISSUANCE: r NO. REVISIONS INDICATED THUS 0 DATE ISSUED FOR PERMIT AND APPROVAL 5/6/08 PERMIT REVISION 6 5 08 11 , TUKWILA = j CITY O JUN 052008 CENTER 9 NA NA 10 NA NA 11 NA NA 12 NA NA 13 NA NA - TENANT: ITT TECHNICAL INSTITUTE r ., r: v 4 SHEET TITLE: ELEVATIONS AND DETAILS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A BY &A 008. FEDERAL COPYRIGHT LAW_ COPYRIGHT TI-7 14 NA NA 1 15 NA NA 16 NA NA 17 NA NA Q 18 NA NA OF 12 0 E 0 CD z CD J W a O W tz co N H- O C) A N 4 J I Ca in C) J c7 V1 U- a C C C� ll cr