Loading...
HomeMy WebLinkAboutPermit D08-282 - EIS - PARTITIONS, DOORS AND FINISHESEIS 610 INDUSTRY DR D08 -282 Parcel No.: 0223400010 Address: 610 INDUSTRY DR TUKW Suite No: Tenant: Name: EIS Address: 610 INDUSTRY DR , TUKWILA WA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Owner: Name: LEHMAN SHANNA Address: 2235 FARADAY AVE STE O , CARLSBAD CA 92008 Phone: Contact Person: Name: KIP KOLODZIEJSKI Address: 1326 5TH AVE SUITE 500 , SEATTLE WA 98101 Phone: 206 -587 -7120 CitAbf Tukwila • Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206- 361 -2989 Contractor License No: DPINCGC066BU DEVELOPMENT PERMIT Permit Number: D08 -282 Issue Date: 07/30/2008 Permit Expires On: 01/26/2009 Expiration Date: 01/31/2010 DESCRIPTION OF WORK: NON STRUCTURAL INTERIOR TENANT IMPROVEMENT, NEW PARTITIONS, DOORS AND FINISHES Value of Construction: $120,000.00 Fees Collected: $2,337.60 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0008 doc: IBC - 10/06 * *continued on next page ** D08 -282 Printed: 07 -30 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: Print Name: �✓1A'i� ����l doc: IBC -10/06 City (*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us L,J,ziafR„„ Permit Number: D08 - 282 Issue Date: 07/30/2008 Permit Expires On: 01/26/2009 Date: - 7 -30-vS I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: O 7- g 0 - e 4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 - 282 Printed: 07 -30 -2008 Parcel No.: 0223400010 Address: 610 INDUSTRY DR TUKW Suite No: Tenant: EIS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 282 Status: ISSUED Applied Date: 05/16/2008 Issue Date: 07/30/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D08 -282 Printed: 07 -30 -2008 • City of Tukwila 16: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Aisles in nonsprinldered buildings shall be a minimum of 96 inches (2438 mm) wide. (IFC 2306.9.1.2) 27: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 29: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) doc: Cond -10/06 D08 -282 Printed: 07 -30 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 32: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110.26(A) thru F(2)) 33: Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110 -22) 34: Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating "ELECTRICAL ROOM" or similar approved wording. (IFC 605.3.1) 35: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 36: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 39: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 40: Prior to final permit sign -off all backflow deficiencies shall be corrected (domestic water RPPA installed, irrigation PIV replaced with a DCVA, irrigation deduct WM upgraded to AMR). This can be done as a revision to this Tenant Improvement permit or under a separate Public Works construction permit. doc: Cond - 10/06 * *continued on next page ** D08 -282 Printed: 07 -30 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: y lc r Print Name: 91 doc: Cond -10/06 • S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Date: p 7 - —6db D08 -282 Printed: 07 -30 -2008 SITE LOCATION Suite Number: 6 Floor: New Tenant: Yes ❑..No Property Owners Name: �E /T Y��'� /m,) l t /f U- P. Mailing Address: D �� n ,9 - g ( * I7 /I Dii5r?Lf DA, Site Address: 191O 14.11aV377 t f 1.42I1/' Tenant Name: e/ Name: /G/P 4,WD zi/e /rit- Mailing Address: /521, 5 IFVe bi/ /re 0 -01 E -Mail Address: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lutp://www.ci.iukwilawa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 7v gerv*s � �Gl p 4-D C- .t E -Mail Address: Q •Applications Forms- Application On Line?- ?006 - Permit Application doe Resised. 9.:006 bh Building Permit No 'be, - � Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: ' R/KiII/l City State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: (ZO() 5 7 re-r e 4 /0/ City Fax Number: Sta Zi p GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 773 7) Mailing Address: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City Day Telephone: Fax Number: Expiration Date: State 2O/O Zip 9v/ es Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 5b Gr t4" rla City State Zip Day Telephone:(c1t) 57,37 1f Fax Number: ( d ) , 57 7 /z Z Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page I of() • BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ I t" / 00 0 Scope of Work (please provide detailed information): /lI1 /it4 Y • /Ua/ ,;7777 en's / , ,GS I hto,sr s Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): *Provide documenta4ion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If ''yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q Applications•Fnrms- Applications On Line'3 -2006 - Pennii Application doe Re iced 9 -200P hh Existing Building Valuation: $ /G . ti ( v, y . No If yes, a separate permit and plan submittal will be required. Floor area of principal dwelling: -- Floor area of accessory dwelling: Page 2 uf6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per Type of Occupancy per IBC 1 Floor 4 f D 5 Z- d jl/L/ A / 4 . / /IBC . / � r Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ I t" / 00 0 Scope of Work (please provide detailed information): /lI1 /it4 Y • /Ua/ ,;7777 en's / , ,GS I hto,sr s Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): *Provide documenta4ion that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If ''yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q Applications•Fnrms- Applications On Line'3 -2006 - Pennii Application doe Re iced 9 -200P hh Existing Building Valuation: $ /G . ti ( v, y . No If yes, a separate permit and plan submittal will be required. Floor area of principal dwelling: -- Floor area of accessory dwelling: Page 2 uf6 BUILDING 0 Signature: Print Name: Mailing Address: PERMIT APPLICATION NOTES — Applicable to all permits in this application • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date Application Accepted: ORIZED AG 5 (( -06 o `Applications Forms- Applications On Line 3 - - Permit Application doe Revised 9 -2106 rh Day Telephone: City Date: sirc.(p6 tot. - SB? -1(to W a State Zip Date Application Expires: I I Staff Initials: 'age () or () Parcel No.: 0223400010 Address: 610 INDUSTRY DR TUKW Suite No: Applicant: EIS Receipt No.: R08 -01675 Initials: WER User ID: 1655 Payee: BURGESS DESIGN City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7276 2,337.60 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Total: $2,337.60 Permit Number: D08 -282 Status: PENDING Applied Date: 05/16/2008 Issue Date: Payment Amount: $2,337.60 Payment Date: 05/16/2008 09:56 AM Balance: $0.00 1,414.00 919.10 4.50 2501 05/16 9710 TOTAL 2337.60 doc: Receiot -06 Printed: 05-16 -2008 COMMENTS: Type of Inspection: Address: /D 7 /45 a,/t72 i Special Instructions: 7, • Date W me L j / — � 'J Q 9 p.m. p eftAT 4- -0 t 1 ` Cl - ... f , Projec ; s Type of Inspection: Address: /D 7 /45 a,/t72 Date Called: Special Instructions: 7, • Date W me L j / — � 'J Q 9 p.m. Requester: Phone -3c4-652Z d ° -2 ,52_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I ' Approved per applicable codes. Corrections required prior to approval. Inspe tor: Date:4 4 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: !Date: COMMENS: Type of,Ffi'specti ' • %, l • f t - �1 J ` \ t al Addr () K ` v(' C-- ' r f-, rP Date Wanted: a.m. I0 , Zg — o iM i\X Phoney 3 r Sr)) f _ ' D � -- 17n n. e. ‘ vi)tfe_ : �r irk Z "7 Ili k R F { ` - g A7161 0 i e- ��-{. ,mo t P. k - ✓AC i,),./KS Project: / � Y- Type of,Ffi'specti ' • %, l • f t - �1 J ` \ t al Addr Date Called: "J f Special Instructions: tions: P 1 Date Wanted: a.m. I0 , Zg — Requester: Phoney 3 r Sr)) f INSPECTION RECORD Retain a copy with permit INSPECTIId NO. CITY OF TUKWILA BUILDING DIVISION /� A• . ov: • per applicable codes. Dbr -71 PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)31 -3670 orrections required prior to approval. Inspectgr: V — ` . Al /� ` rate: 60 K U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: Project: . ss Type of IryspectioT � ; ( a ` �� J� l0 Addre : L A o wit ,5)v S 'Special ,N, Date Called: 7 Instructions: Date Wanted:/0-2 08' ,a.rnn. Requester: Phon � , 0(0 -3 4 1 ( '3Dvr INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 _(206)431 -3 )z_ 11 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r-19 j - 0 pc-ofroz,j Af Xidr d 1 Inspeqor: 'Date: El $60.00 REINSPECTION FEE R'QUII D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Projec C 1 S Type of Inspection: Li s p up, ( ...lc Address: Date Call Special Instructions: Z. Datlante� �� p.m. Requester: Phone No -266 - ?s - 6 3�(i) 112_ INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION g. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspecr ' Date: 5 , 2 D ? 0 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: . Address: ( 4 �( .t i " 1 Date Called: J� l S; 9i ,' 1 rr;tT` C. -r)Jrf e,' . Ai I . I) ,' (r. ,- `7Y ; __..• le d 4 4 .7(7 �) / /I f ) . Jr' () ,..,(.. T c c.'l : -4 i ; -• (A e j e.__,\. 7 .) sp 1 Project: Type of Inspection: . Address: ( 4 �( .t i " 1 Date Called: J� Special Instructions: 7 Date Wanted: Jt a.m ., p.m. Requester: Phone No: ` INSPECTION NO. 0 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION gx 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. Corrections required prior to approval. Date: k / ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: �a.e .n r ` v01, -a7ti- �"� ` '„' 6c! _":J5,ss1£ Project: Type /tZY ection: Address: 610 -177/1/.4. ctt 1. rr Date Called: /) 313a Al Special Instructions: Date Wanted: 03 /3//O5 a. Requester: ,/ Phone No: 6 594 - o$ so (510) INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. CO ENTS: (Inspector: i75 INSPECTION RECORD Retain a copy with permit - D08- 01,1 PERMIT NO. (206)431 -3670 'Date: c ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project . .e-1 ic i GelPAe w Type of Ins ection: c4 I'► P AL Address: .' 0 Suite #: . s ,� r v�� Contact IN on: e i ci f Special Instructions: Hood & Duct: Phone No.: 4 j 5/t- $oo1 Needs Shift I nspection: y Sprinklers: A) Fire Alarm:.' Hood & Duct: ,i.) _ Monitor: Pre -Fire: Permits: id - Occupancy Type: & INSPECTION NUMBER Approved per applicable codes. t • Word /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain a copy with permit a-- - PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 - 206 -575 -4407 Corrections required prior to approval. COMMENTS: Cot Y., e t oiuS "e.. ( - S 'P "I 5 .1)et✓lcno_ - Inspector: Date: '41/2 y ( Hrs:: • $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila. Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 NOU -20 -2008 10:14 REIT MANAGEMENT Q- vpc7ty 1WU4J raarst riZ Leasing ) mfiiver'Eteciaiue Ark 617 In&rstry Drive '71444 'Wasiiingtun 9X188 REIT MANAGEMENT & RESEARCH LLC PROPERTY M,ANAcumfiNr I)IV111ON TACSIMILE 7'4ANSMI77tL MEET 7o: C ix L From: r( . Receive° No4 2 0 1St get le( (206).57,5-6675 fad 000575 Ta 2umbe, Z&9 51 , o(oS Date: / 1. z 0 s Phone Number. Fages: ❑'Urgent ❑ For Review ❑ (Please Com ment ❑ q'(ease Reply ❑ 0 Recycle U10 -- Y■01A -11( 10) '1\kiLkoit \ WA 971sv ;Me information is iruendedoafyforefe pew's) or entity to r4ntf it is addrmedundinay contain anfidentia( proprietary. ant/orprfrdk8almatc & An) rvlscµ rumrmnissiun a uucnninatnm nrru6eru se of or taking of auy an in re fiance upon, this inin nareua 6y persons orwunits odic titan sfie intendrdadpieni is pmhibited rfym, nlrimifsfiG in army, pkxrse mntaa tfe fir and (skit the material :irm allannputen: P.01 INITIAL TEST PASS, FAIL O DCVA/RPBA CHECK DCVA/RPBA CHECK RPBA Pv6A SVBA VALVE NO. 1 VALVE NO. 2 OPENED AT %a. PSID / # t CH ECK 9, 4 PSID AIR INLET OPENED AT PSID LEAKED 0 TIGHT g 9 Q vv PSID LEAKED 0 TIGHT CR v PS10 DID NOT OPEN O CHECK VALVE HELD AT PSID AIR GAP OK? Y e5 NEW PARTS AND REPAIRS CLEAN REPLACE PART 0 0 CLEAN REPLACE PART 0 0 CLEAN REPLACE PART 0 0 O O o o 0 0 LEAKED 0 o o O 0 O O O O O O 0 O CLEANED o REPAIRED 0 O 0 0 0 0 0 TEST AFTER REPAIRS PASS 0 FAIL o TIGHT 0 LEAKED 0 Pslo TIGHT 0 LEAKED 0 PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID NOV-20-2008 10:14 REIT MANAGEMENT MacDonald- Miller FACILITY SOLUTIONS , Backllow Prevention Assembly Test Report ASSEMBLY ID: 41 4J . P/57A(L PASSED ANNUAL TEST: YES 0 NO 0 P.02 NAME OF PREMISE j21 f 0?. /arile.r►m eket COMMERCIAL ® RESIDENTIAL 0 SERVICE ADDRESS 610 r 'b/7y p R i _ __.. _CIry7 (q zIP ?PI g CONTACT PERSON L Irt? G 1' Phone P00_52.5- 6( s Fax OO?T75- l y/5" LOCATION OF ASSEMBLY NeXT 70 /,ie7w ' ,4/er l'fl4I c. Box tiv g{OT 801(' DOWNSTREAM PROCESS D ®/Yr T/G DCVA 0 RPBA J$j PVBA ❑ OTHER: NEW INSTALL j8. EXISTING 0 REPLACEMENT C1 OLD SER. # PROPER INSTALLATION? YES. NO 0 MAKE OF ASSEMBLY am MODEL 061 /n -a QT' SERIAL NO .A3R3342 SIZEae AIR GAP INSPECTION: Required minimum air gap separation provided? Yes 0 No 0 REMARKS: TESTERS SIGNATURE: TESTERS NAME (PRI REPAIRED BY: FINAL TEST BY: CALIBRATION DATE ? /!O / 07 GAUGE tt /?7J Detector Meter Reading /WA LINE PRESSURE CONFINED SPACE? CERT. NO. ey DATE g 027' Phonepe $ An- Y411 DATE CERT. NO. DATE MODEL SERVICE RESTORED? YES X NO 0 I certify That !his report is accurate, and / have used WAC246- 290 -490 approved test methods and test equipment NOU -20 -2008 10:15 REIT MANAGEMENT MacDonald - Miller FACILITY SOLUTIONS Backflow Prevention Assembly Test Report ASSEMBLY !D:ALetV PASSED ANNUAL TEST: YES 0 NO 0 NAME OF PREMISE K err SERVICE ADDRESS 6 .rwaisrity CONTACT PERSON" © re- 4 q__E. LOCATION OF ASSEMBLY7 4 Ar DOWNSTREAM PROCESS .Zg e AT7 AJ NEW INSTALL EXISTING 0 REPLACEMENT 0 OLD SE 'sGa MODEL OF ASSEMBLY RPBA PVF3y A OPENED AT PSID INITIAL TEST PASS tit FAIL O NEW PARTS AND REPAIRS TEST AFTER REPAIRS PASS 0 FAIL 0 DCVA/RPBA CHECK VALVE NO. 1 LEAKED 0 TIGHT $ 0 0 ❑ 0 2. 7 PSID O 0 O 0 ❑ TIGHT 0 LEAKED 0 CLEAN REPLACE PART PSID O 0 o O O 0 o O O ❑ TIGHT 0 LEAKED 0 .� de ! '.1 — COMMERCIAL fi31 RESIDENTIAL 0 �� .� � L b �__cl wl zIP 9 8t 88 — — Phone Fax � _ ' S Fax (0 Ste' $ L _ DCVA. RPI3A O PVBA O OTHER:_ R. # PROPER INSTALLATION? YES INO C L 9(/ SERIAL NO. DI 35: SIZEgt) DCVA/RPBA CHECK VALVE NO. 2 LEAKED 0 TIGHT $ 6. PSID CLEAN REPLACE PART PSID AIR GAP INSPECTION: Required minimum air gap separation provided? Yes 0 No 0 REMARKS: TESTERS SIGNATU TESTERS NAME (PRINT): REPAIRED BY: FINAL TEST BY: tut CHECK , ^ PSID AIR GAP OK? CLEAN REPLACE PART 0 D 0 O O O O 0 O OPENED AT PSID #1 CHECK PSID P.03 AIR INLET OPENED AT DID NOT OPEN 0 P510 CHECK VALVE HELD AT PSI() LEAKED 0 CLEANED ❑ REPAIRED ❑ AIR INLET _ CHK VALVE _ PS:D PSID Detector Meter Reading � / A LINE PRESSURE 1'T I CONFINED SPACE ?__ /L CERT. NOZyyl9 DATED__. PhoneP06 ( .— DATE CERT. NO. __DATE___ CALIBRATION DATE .9 l/O / D ? GAUGE # j9! 7/ MODEL 7 p SERVICE RESTORED? YESKNO 0 I certi%Sr that this report is accurate, and I have used WAC 246- 290 -490 approved lest methods and test equipment, TOTAL P.03 May 28, 2008 Kip Kolodziej ski 1326 5 Ave, Ste 500 Seattle WA 98101 RE: CORRECTION LETTER #1 Development Application Number D08 -282 EIS — 610 Industry Dr Dear Mr. Kolodziejski, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Public Works Departments. At this time the Fire and Planning Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, encl ifer Marshall it Technician City of Tu ila Department of Community Development Jack Pace, Director File No. D08 -282 P:\Perntit Center■Correction Letters \2008\D08 -282 Correction Ltr #1.DOC wer o • Jim Haggerton, Mayor AM() .cnuthrcnter Rnu1Pt/aril_ .Saito *inn o Tukwila Wachinatnn OR1RR • Phnno• 2f/_4l1_2,5711 • Fes 2/1/6_421_2AAC Building Division Review Memo Date: May 6, 2008 Project Name: EIS Permit #: D08 -282 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. You show a sliding door at one of the doors to the situation room. Two code sections would apply. Section 1008.1.2 requires doors to be side hinged when serving more than 10 occupants and section 1008.1 requires doors provided in excess of the number required by code need to comply same as required exit doors. 2. The insulation for the wall between sales room 610 and the warehouse appears to be shown as R -13. Table 13 -1 of the WSEC would be applicable for new walls as well as the ceiling or roof of the area converted from warehouse to office use if the warehouse was unheated or semi- heated. Please show envelope changes as required per Table 13 -1 or show how existing condition complies 3. Please provide occupant load count for each room. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. (P:Joanna/Comments 1 D08 -282 PW) 4 - . ' • • o • PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards DATE: May 23, 2008 PROJECT: EIS Tenant Improvement REVIEW #: 1 PERMIT NO: D08 -282 PLAN REVIEWER: Contact Joanna Spencer at (206) 431 -2440 if you have any questions regarding the following comments. 1) In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. Since the project includes alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code, including installation of an approved backflow prevention on the fire line and the domestic water supply to the building. The City has determined that the subject building has deficiencies on domestic water service and landscape irrigation. a) Domestic Water Service A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Box/Hot Rock or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works strongly recommends a power supply for the freeze protection enclosure. Please specify on your plan backflow size, manufacturer, and model number and submit a cut sheet of the proposed device. b) Landscape Irrigation Building has a landscape irrigation system, however the existing Pressure Vacuum Breaker (PVB) shall be removed and a Double Check Valve Assembly (DCVA) installed and tested by a certified tester. The existing irrigation deduct water meter shall be upgraded with a TRPL register that is compatible to the SENSUS automatic reading system.. I have enclosed Development Bulletin C5, which spells out design and installation requirements for cross connection control. A separate letter addressing these deficiencies was mailed to REIT Management, LLC, representing property owner. The Public Works Director will withhold issuance of this Tenant Improvement permit until the backflows on domestic water and landscape irrigation are installed and irrigation meter upgraded, or the Permit Center receives plans for items la) and lb). Applicant can post a bond for items la) and lb) in the amount equal to 150% of the design, installation, and testing cost of subject devices, together with a letter stating the installation by a certain date. 03 -02 -2008 KIP KOLODZIEJSKI 1326 5TH AVE SUITE 500 SEATTLE WA 98101 RE: Permit No. D08 -282 610 INDUSTRY DR TUKW Dear Permit Holder: Jim Haggerton, Mayor epartment of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/22/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall, t Technician Permit File No. D08 -282 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 Joanna Spencer - EIS tenant improvemerean check #D08 -282 From: "Kip Kolodziejski" <kipk @burgessdesign.net> To: <jspencer @ci.tukwila.wa.us> Date: 06/12/2008 4:04 pm Subject: EIS tenant improvement plan check #D08 -282 CC: "Alake, Loretta" <LAlake @reitmr.com >, "Kincaid,... Joanna, Based on our conversation today, please release the building permit listed above. The building management is aware of the public works corrections. They are in the process of submitting for a public works permit. They are now aware that the work depicted in the correction letter must be complete before the final inspection is given by the city. An alternative is for the building management to post a construction bond with the city. Kip Kolodziejski I Burgess Design, Inc. I interior architecture D: 206.342.0127 T: 206.587.7120 F: 206.587.7122 1326 Fifth Avenue Suite 500 Seattle, WA 98101 burgessdesign.net PERMANENT FILE COPY, 008*2 S2 Joanna Spencer - Re: EIS @ 610 dustry Dr From: Bryan Still To: Joanna Spencer Date: 05/20/2008 6:59 am Subject: Re: EIS @ 610 Industry Dr CC: Han Kirkland Hi Joanna, No fire. Need RPPA on domestic. Need to remove PVB and install DCVA on irrigation. Need to upgrade irrigation deduct meter to AMR. Thanks Bryan »> Joanna Spencer 05/19/2008 4:22 pm »> Bryan, Are they current on their backflows ? Thanks, Joanna ====1" PERMAN ENT FILE COPY 1 Documents/routing slip.doc 2-28-02 D PARTMENTS Buil g [vision ACTIVITY NUMBER: D08 -282 DATE: 6 -9 -08 PROJECT NAME: EIS SITE ADDRESS: 610 INDUSTRY DR Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued Q • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP Fire Prevention Public Works (( Structural �lAl v I Sg DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete LJ Incomplete Comments: Permit Center Use Only ' INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROA(JTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 6-10 -08 No further Review Required DUE DATE: 7 -8-08 Not Approved (attach comments) ❑ DATE: Planning Division Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Uri t uildlng Divi IC Public Works PERMIT COORD COPY • PL N REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -282 PROJECT NAME: EIS SITE ADDRESS: 610 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # DATE: 05 -16 -08 Response to Incomplete Letter # Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -20 -08 Complete Comments: n Permit Center Use.Onlif . . . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: DUE DATE: 06 -17 -08 Approved n Approved with Conditions ❑ Not Approved (attach comments) U Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only. . CORRECTION LETTER MAILED: Departments issued corrections: Bldg 'j Documents/routing slip.doc 2- 28-02 Incomplete 22 i re P Fire ❑ tI�L 6.2v Planning Division ❑ Permit Coordinator Ping ❑ PW Staff Initials: Not Applicable DATE: r 1 _, City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: Date: (J .q — o g ❑ Response to Incomplete Letter # Response to Correction Letter # 4 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: E) S Project Address: Kec Jilve ?per 3�Oaract6 Pc& �c - e* Contact Person: Ky I IA Zl S 1 Phone Number: V Summary of Revision: Sheet Number(s): • dog- Az Steven M Mullet, Mayor Steve Lancaster, Director 0 9 I8b 4 (h poor c ) 2s <C\ a COLM/ ' \ sk1lcdvi Tf N 1 &s 13 Occurart\- \Gad (cio4 "Cloud" or highlight all areas of revision including date o revisio Received at the City of Tukwila Permit Center by: 11, ' _I 'Entered in Permits Plus on (.0 - Q - U0 lapplicationsVorms- applications on linelrevision submittal Created: 5 -13 -2004 CM OF Tt1KW? A IJUN 0 9 2008 oRSfAAr MI-T N T Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 DEVELOPERS NDE CO 791078C 01/31/2008 Until Cancelled $12,000.00 02/25/2008 4 CBIC SA6377 01/31/2002 01/31/2008 $12,000.00 01/09/2002 3 CBIC SA6377 01/31/1998 01/31/2002 $6,000.00 2 CBIC SA6377 01/31/1997 01/31/1998 $6,000.00 1 AMERICAN STATES INS CO EX595197 01/31/199401/31/1997 $6,000.00 Name Role Effective Date Expiration Date DODSON, WILLIAM PRESIDENT 01/31/1994 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. D P INC GENERAL CONTRACTORS Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County D P INC GENERAL CONTRACTORS 2063612989 19909 BALLINGER WAY NE SEATTLE WA 98155 KING Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 601515833 ACTIVE DPINCGC066BU CONSTRUCTION CONTRACTOR 1/31/1994 1/31/2010 DODSOPI101 JB GENERAL UNUSED Business Owner Information • • Bond Information https:// fortress .wa.gov /lni/bbip/Detail. aspx ?License= DPINCGC066BU Page 1 of 2 07/30/2008 GENERAL NOTES 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND /OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND /OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS-BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND /OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE UST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. SYMBOLS ELEVATION REFERENCE SYMBOL DETAIL ID L A.06.XX SHEET NO. D SECTION REFERENCE SYMBOL DETAIL REFERENCE SYMBOL COLUMN AND /OR GRID LINE SYMBOL DIMENSION LINE: ll 20' - 0" L ANGLE @ AT CENTERLINE j + INDICATES FINISHED I SURFACES TO ALIGN DRAWING TITLE BAR 1127 DOOR SYMBOL DOCUMENT SHEET SYMBOL UtIAIL IUtNIII ILAIIUfI DRAWING TITLE GRAPHICAL SCALE FLOOR ELEVATION SYMBOLS 92' -O" +1' 4" NOMINAL FLOOR �^ ELEVATION HEIGHT (ABOVE /BELOW) BUILDING SPACE / ROOM ID OFFICE SPACE NAME SPACE NUMBER -. KEYED SHEET NOTES GLAZING SYMBOL �--- REVISION NUMBER ARCH / INTERIOR ABBREVIATIONS ADJ --- ADJUSTABLE AFF - ABOVE FINISH FLOOR ALT - ALTERNATE ALUM - ALUMINUM APC -- ACOUSTICAL PANEL CEILING APPROX - APPROXIMATE ARCH - ARCHITECTURAL ACT - ACOUSTICAL CEILING TILE AV - AUDIO VISUAL BLDG - BUILDING BOT - BOTTOM CAB CL CLG CLR COL CONC CONF DEMO DEPT DF DIA DIFF DIM DTL DW DWG EA EL ELEC ELEV EQ EQUIP EXT FA FD FE FEC FFE FIN FLUOR FLR FO FOIC FTIC FURR GA GC GL GWB HC HDW HM HR INCL INFO INSUL LAV LF MATL - CABINET -- CENTER LINE -- CEILING - CLEAR - COLUMN -- CONCRETE - CONFERENCE - DEMOLITION - DEPARTMENT - DRINKING FOUNTAIN - DIAMETER - DIFFUSER - DIMENSION - DETAIL - DISHWASHER - DRAWING - EACH - ELEVATOR - ELECTRICAL - ELEVATION - EQUAL -- EQUIPMENT - EXTERIOR - FIRE ALARM - FLOOR DRAIN - FIRE EXTINGUISHER - FIRE EXTINGUISHER CABINET - FINISH FLOOR ELEVATION - FINISH - FLUORESCENT - FLOOR - FACE OF - FURNISHED BY OWNER, INSTALLED BY CONTRACTOR - FURNISHED BY TENANT, INSTALLED BY CONTRACTOR - FURRING - GAUGE - GENERAL CONTRACTOR - GLASS - GYPSUM WALLBOARD - HANDICAPPED - HARDWARE -- HOLLOW METAL (STEEL FRAME) - HOUR - INCLUDED OR INCLUDING - INFORMATION -- INSULATION - LAVATORY - LINEAR FOOT - MATERIAL MAX -- MAXIMUM MDF - MEDIUM DENSITY FIBERBOARD A. DEFINITIONS: MECH MEZZ MFR MIN MISC MTD MTL N/A NIC NTS OC OFF OPNG OVHD P PART PERF PERIM PERP PLAM PLYWD QTY (R) RA RCP REC REF REFR REL REV RM RO RTD SCHED SF SHT SIM SPEC SPKLR SPKR SQ STD STL STOR STRL STRUC SYM M TBD TEL TEMP THK TO TOS TYP UON UPS VCT VIF W/ WC W/O - MECHANICAL - MEZZANINE - MANUFACTURER - MINIMUM - MISCELLANEOUS -- MOUNTED - METAL - NOT APPLICABLE - NOT IN CONTRACT - NOT TO SCALE - ON CENTER - OFFICE - OPENING - OVERHEAD - PAINT - PARTITION --- PERFORATED - PERIMETER - PERPENDICULAR - PLASTIC LAMINATE - PLYWOOD - QUANTITY - RELOCATED - RETURN AIR - REFLECTED CEILING PLAN - RECESSED - REFERENCE - REFRIGERATOR - RELOCATE - REVISION OR REVISED - ROOM - ROUGH OPENING -- RATED - SCHEDULE - SQUARE FEET /FOOT - SHEET - SIMILAR - SPECIFICATION - SPRINKLER - SPEAKER - SQUARE - STANDARD - STEEL - STORAGE - STRUCTURAL - STRUCTURAL - SYMMETRICAL - TO BE DETERMINED - TELEPHONE OR TELECOM - TEMPERED - THICKNESS - TOP OF - TOP OF SLAB - TYPICAL - UNLESS OTHERWISE NOTED -- UNINTERRUPTED POWER SUPPLY - VINYL COMPOSITION TILE - VERIFY IN FIELD --- WITH - WATER CLOSET - WOOD --- WITHOUT DEFINITIONS AND DIMENSIONS 1. 'TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B. DIMENSIONS: 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTFD. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF ". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE yr FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. BUILDING SUMMARY . PROJECT ADDRESS: EIS ANDOVER EXECUTIVE PARK, BUILDING 8 610 INDUSTRY DRIVE, SUITE 610 TUKWILA, WA 98188 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES INTERNATIONAL BUILDING CODE - 2006 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2006 ICC /ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: ASSUMED VB FIRE RESISTIVE SYSTEM: NON - SPRINKLERED OCCUPANCY TYPE: 'B' OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: NA EXIT STAIR ENCLOSURES: 1 HOUR CORRIDORS: NA 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 2,905 SOFT 'B' OCCUPANCY= 2,366 SOFT; 'S1' OCCUPANCY= OCCUPANT LOAD FACTOR: 100 SEATTLE NUMBER OF TOTAL PROPOSED OCCUPANTS: 31 BY SOFT.; NUMBER OF EXITS REQUIRED: REQUIRED, PROVIDED MINIMUM EGRESS WIDTH REQUIRED: 44 INCHES COMMON PATH OF TRAVEL: 75' 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. NEW PARTITIONS, DOORS, FINISHES. 7. VALUE OF CONSTRUCTION: TBD STREET MAP 5trar;ct 3 is ANDOVER EXECUTIVE PARK BUILDING 8: FIRST FLOOR SUITE 610 Flwr review " pR l is subject to errors a cessions. 5. r documents does not authorize /�pprcv� ` ��t4L'ttct: � . Re micfatcori of any adopted or order � p O' approved Field Copy* conditions is acoeec : " 4 By Date: City of Tukwfla BLIP DING DIVISION FACILITIES - 2003 537 SOFT /G KEY PLAN / FLOOR PLATE - 24 BY FURNITURE SEPARATE PERMIT REQUIRED FOR: Mechanical LElec tricj srPlumbin Gas Piping City of Tukwila BUILDING DIVISION /1 - PROJECT TEAM TENANT: EIS Tukwila, WA 98188 ARCHITECT /DESIGNER: Burgess Design, Inc. 1326 - 5th Avenue, Suite Seattle, Washington 98101 Tel: 206.587.7120 Fax: 206.587.7122 ATTN: Kip Kolodziejski BUILDING MANAGER: REIT Management and Research LLC Andover Executive Park, Building 9 617 Industry Drive Tukwila, WA 98188 Tel: 206.575.6675 x303 Fax: 206.575.1415 ATTN: Loretta Alake REVISIONS No changes shall be made to the of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan suhrnl ?!al and may include additional plan review fees LEGAL DESCRIPTION / PARCEL NO. LEGAL DESCRIPTION: PARCEL NUMBER: 022340 --0010 DRAWING INDEX DRAWING ISSUED CO CO CO 0 0 0 X X X X X X X X X X X X X X X X X X 97 MECHANICAL ENGINEER: 500 TBD - Bidder Design Build ANDOVER INDUSTRIAL PARK #5 LESS UP RR OPER R/W GENERAL_ G.0.2 SITE PLAN ARCHITECTURAL / INTERIORS A.9 1 EXIT GENERAL CONTRACTOR: TBD PLUMBING ENGINEER: TBD -- Bidder Design Build by G.C. by G.C. ELECTRICAL ENGINEER: TBD - Bidder Design Build by G.C. FIRE /LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. G.0.0 COVER SHEET / PROJECT INFORMATION G.0.1 PROJECT NOTES A.2A.1 DEMOLITION /CONSTRUCTION PLANS A.2C.1 REFLECTED CEILING /POWER & DATA PLANS DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS AREA OF WORK EXIT I C! .11 e: ROOM HAS NO MORE THAN 6 OCCUPANTS AND PATH OF TRAVEL FOLOWS AS SHOWN, NO LOCKS ON DOORS, ADDITIONAL EXIT SIGNS PROVIDED EXIT REVIEWED FOR CODE COMPLIANCE t JUN 1.6 2008 O Of Tukwila BUILDING DIVISION NO CHANGES TO EXISTING EXITING COMMON PATH OF EGRESS: 69' -0" Tenant: EIS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BLDG 8 610 INDUSTRY DRIVE, SUITE #610 TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design I interiors Q architecture 1326 Fifth Avenue Suite 500. Seattle . WA 86107 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2008 Approved by: Date: CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT EQUIPMENT AND FURNITURE INSTALLATIONS. CONSTRUCTION AND /OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS, SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER / REPRESENTATIVE AND THE TENANT. Professional seal 7196 No. Issue Description REVIEW SET PERMIT SET REVISION Project No: 08- 3402 -00 KIP G. atOLCDZIEJSKI STATE OF WASHINGTON JUN 0 9 2r I Drawn by: MK Reviewed by: KK Date 04/24/08 05/16/08 06/09/08 CORRECTION COVER SHEET / PROJECT INFORMATION DOS • 2.5 Original drawing is 24" x 36". Scale entities accordingly if reduced G.0.0 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CA () Rl IIC AT1nNS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. DM$JON I - GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. 11. VERIFY ALL BUILDING CONSTRUCTION RULES WITH BUILDING MANAGEMENT. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEIUNG, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMS(ON VI - ARCHITECTURAL CAPPENTRY AND CASEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A W_L ARCHITECTURAL WOODWORK 011AI ITV STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE: HIGH - PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 6. SHELF EDGING TO BE VINYL, UON. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII -- DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FAS I 1 NERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1-1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 08810 - GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DMSION IX - FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES. 09500 -- CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEIUNG AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NFW CEILING TO ni D, CnNTRAnTOR SHAT 1 REVIEW Al I CFIT INGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCONTINUITIES IN THE CEILING WITHIN 10 DAYS. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 0900 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER - REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6 OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 09680 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1 /4" OVER 10'. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES A) PAINTED WOODWORK TO BE FINISHED WITH ONE (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH A COMMERCIAL GRADE CLEAR SATIN VARNISH. AS INDICATED IN DRAWINGS. (1) COAT PRIMER AND TWO SCHEDULE AND SEALED WITH 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. DMSION XII - FURNISHINGS 1Z500 - WINQQW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE --NEW CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI -BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. DMSION XV - MECHANICAL, 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 - FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE IIIIVRNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 5 - C 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC 5YS I EM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 15" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOC 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF INSTALLATION OF TENANT'S NEW FURNITURE. 16500 - LIGHTING THE TELEPHONE SWITCH, UMENTS. ELECTRICIANS DURING THE 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL. 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN /BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER /DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS. 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON J. UUWN LKihi I J bhiUWN IN I hit_ t:tN I tli U• (:.ILIN(, !ILL WI MU I UIMh.N5IONS Ah< . 10 tat LOCAL r.D IN THE CENTER OF CEILING TILE, UION. 4. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING - HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFELY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL RE- CIRCUIT AND RE- SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. • Tenant: EIS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BLDG 8 610 INDUSTRY DRIVE, SUITE #610 TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design `interiors Q architecture 1326 Fifth Avenue Suite 500 . Seattle . WA 98141 TEL: 206.587.7120 FAX:206, 537.7122 M reproduction & intellectual properly rights reserved c 2008 CODE COMPLIANCE REVIEWED FO APPROVED P JUN 1 6 2008 CIi Cf T ukwila BUILDIIN G DWISION Professional seal No. Issue Description REVIEW SET PERMIT SET REVISION Drawn by: MK e , KIP c. 'OLCDTEJSKI STATE OF WASHINGTON Project No: 08- 3402 -00 PROJECT NOTES „Ia 0 '. Reviewed by: KK Date 04/24/08 05/16/08 06/09/08 OB28Z Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.1 .t.... er1 1.."' t - F c,,,3--•-‘- , - ..... N , 4,t , ..1 ,4 „ , ne -1,:- - . l -- • , 0 . --...- - , 0, s '.-, ..•- tqr • ' „: ,..;:' 'r 4 • ''' i. .7. '', '," .3' .... '' 'A"t .. • e . .,*. 4 - "r 4*7 r' ' r 4. •-4. 4 ..r • 7 .._ .-,.., 1 el - ,e,... /.. F 4 1 4 . ti V • ,, - 1 1" . S - - • .--- ' • 1,1 -''. - : 4 :..s. 41, 1 0 . :1-... .....,.- ir • "el. 7% • .v..pl., . ,7.. ' .4 , -.; ' r -1 ' k . • ,,. . , , , 0 .. -„, , . = t 44 . 74,4 .. • .. I. , •,,...,„, -. ri. V %!*•••• te ii %VP ' •- . - 1.1 ' . • ' 1 , -, • - 0 2 ? - • - . ' .. Z•41441,/4. ;P scr: '1,I1, ..4. ' 1 i :L • • •,_ , • :1 . ,, . 4 A • l 7 ± 117 - • 57.: • at( 1 - • 4- . 1 - ' • • • . „. r • , tikeee 47 fk- ' t co Ill CL < co LU U.1 - LU < 0 a- 0 co LU fv • Cr LU > }-- Ili 0 n > z < ii V T V 4 " - Y14 1 .4 • . . 4 ; • - F ") :Z7 • 4 - SV ' S1 Vt N 41 OW ONIVYAR r1/17 ‘5 . FI V ; 44 • , -1 • - • "4. • • r " I. g 4 54 9 Iv?* :. • 1 1 70. ."1 ' 1 •. 4 F 4 • " 141 ' • . * . MIMS, 0 ' 1 ef f 5_V ltqF. . 04 '-• < 4.1 . 1.. ... ,... „ *• '..., .r."1,:: .. • • E 1. ',41 ir e • • • F ` " ,... I ". . , 1 • ,.."... 1 4,..., . .r. I' -• e ..,,,-,',". t ,ogtrA • -. - 4 - A... ""'t'4 . - • *4 i•iti;j1 - -1 " ' t• if.' V - .... J . w... .--0.-•tar -.,,i0 -• - • - - , - .. - t • ..- k "- . ':: -4 4, .. kt ft 1. „. • . , ;, , .. ,E ,.0.. , -.„. 0,1 , • :.....„ , . - - 4- -, • ,-..r.. • , :r .4. 11 g . . ../, •r7F *„... „L _ ,.,- ---. , P .. f • 1 . - -I , t , „„ , . ,g • -4:i_, 7...-.e. si , • 7. i eh,...P.'” rL 14' 4 ' • V VF .114 ,c.pett .t9i Ai fe, •1.....x1•1•11.64••••■••••.4,,,...S.MATCW,I...* .74 0 -," `t.F w td 1.. - ' , - ' 1.74 ,,, , . ,,..t I,,. I: ; 4 "" • 0, :,t 0 ' ' ' '' '''. Fr a r' a no • 4.. Ct. 0 0 co [NI U nI ra 41 k tJL ltt,fte000 k • 1 j .41010eter rFrrto tl 1 ; 4411#,IIIV!Mthr SOlfr; 1 , 4 0r•kb,„,. • • ;pro: • t Sdi .14,7 .ti • ParY,ki 4 V • _VW . b4 , .• a I. CAL1.11$ NO Arite of tor ' et. „it rtr • , 44 •-"'" r , 1 4 t4P; i ig r ..' 1•4 1 7 las.• - • - r . ..4".•N sy ... iv .I" Z'il.1 4 T .." ......*- l' ts - : . :t 1 ;4•is*II r I A, t...14..c.s. it iss.,' - • tr.o.se•-s, - -. 'Is ) NlrY. r, „,.. ., P .," --, t`,... 4 .0(' if ...it.' lr ,...,, , ••... . • -....r- - 0 , 1,c1 , - ---- - f - =-- -Irl. ''" "-• -L• . 'it.. •. • • V VF .. .44,611.4....:..si.V.th:..........14 - ...,4, — , -.4.41441 - ra''.”*". '"...k•s•nW4•"1"..........* 'n•J'•••......r..'•L''C•.:.*•"-''-'t,,S '''...,-,,,-,••1,40t,,d,,,,,v4 n 4 J - I • " F • t; '' ' • • I , 7 - 4 VF • , . 0, Fn • V "4'4 . t• 1 , ....,. 0. r * t :rr . ... ri 4.. . ',.. t 4 1 ,t . • . nt., n. .. I &1 i 'i $4; V - "° ' '' : 1 5 .,, 4 .4 , ii .4 ' !.- -.,1 '" : , .4 • t , il • , . • I s 4 r .. i . r„ .... ..,. , , ,._ , .. ' V. i . .1 ! -ni • - • i - `r . 4 st.,ss ; w, f- Neihtfre ' — • 51; 0..fr 7 ,.; • • ' • 14- , kx• t. l e? . • WO4 ' t 7 • - '71;;• . , k - •,. a • 44,0 I • • /41 A. • '.*** - • " 7 ■ % ' IV I Fl ..- I • - 1.11 V 0 Lii F V 41i21 4 A ri - A d‘l s 1"--‘v • *..:-''';?•".".• • id^ :t'ks T.. Lr .401.514.4.44-Wtrk°' ' ' 4.' • S. ;v•V iZt'' - 7 .rsa." : • • s • ...k. , !,....-.*.,,' ,.. • ,.: • o.„ v . i 4 1*, , • .. ,.,, ,,;.....-.4 ...... „ T....J:7 1 ....4 r,..m , 0.0,7 - - .P ',.......*t."a .1;7•.0 k . KAI - w I' '7E: gele)7 ••• .i_R 't 4 "'. rga - - • ,or p, ,,_,. ,,,,,.: L c... it 7 ... . ..k1 I :L7 .. itl q , • :5 a .... .,.._ , ' 14 • ,5 g z • E.. .-Z a - ....... id 15 i c 4 tt 1 _ iF As 41 ! E.- - • W V -,-,-.;.....,..1 ,i.,.. • c. - - 4 1 . .1 ,, a:" . ,-t " - ,.'.i "E < Z it .,,,,. )V 0.t. .17 ti• 4 "VD • 07. "iti , „, • ,„ • — _ rf ."‘ VVVFVF ri! r V,Ftn ;.• 1 nF ':" • . .a 011'1 • •, VV FF 0 5 : If) I VV tf' 50. ot FrI FrI an 1r V 5 -I • 1 , „ '„P" V F F V t - t e. •• • 1.... III V In V VF F tan' kV; , • .'' r 0"P 7 • - • CEILING LEGEND LIGHTING SYMBOL KEYED RCP NOTES - SYMBOL DESCRIPTION /SPEC c===== EXISTING 1' X 8' FLUORESCENT FIXTURE TO BE REMOVED. O. EXISTING SOFFIT AT 7' -0" A.F.F. OF HVAC IS POSSIBLE DELETE GWB SOFFIT AND REPLACE WITH NEW BUILDING STANDARD ACT GRID. COST DEDUCTION FOR OWNERS APPROVAL CONDTnON IF POSSIBLE. ALL NEW CEIUNG 11LE AT ROOM #603. TENANT HVAC NEEDS IN NEW OFFICE AREA. CONTRACTOR TO PROVIDE ALL CODE REQUIREMENTS BUILD CONTRACT FOR NEW OFFICE AREA. DEDICATED DUPLEX OUTLET JUNCTION BOX EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. VOICE & DATA COMBINATION OUTLET ri r>r1r k Ar t I k ITrn r r1 iinrr' I L v u f\ IVI V V I N I L LJ !Jr- V I I., C J IkDO EXISTING 1' X 8' FLUORESCENT FIXTURE TO BE RELOCATED <> IF DEMOLITION PROVIDE I N r .7 I. EXISTING 2' X 4' FLUORESCENT FIXTURE TO BE RELOCATED. 0 NEW EXIT SIGN. COORDINATE NEW FINAL LOCATION WITH CODE OFFICIAL EXISTING a PROVIDE N/R NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE EXISTING HVAC FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. a VERIFY WITH UNDER DESIGN < Wy f /1/ NEW 2' X 4' CEILING GRID HE S ITEM. MATCH EXISTING NEW GWB SOFFIT, MATCH EXISTING HEIGHT LIGHTING SUMMARY—FOR AREAS 0 F EXISTING `: / CEILING LEGEND CONTROLS 2004 Washington State Nonresidential Energy Code Compliance Form - SYMBOL DESCRIPTION Lighting Summary LTG —SUM 2004 NFW SWrTCH HICIA ICIN Project Info Pfoject Address: EIS —AREA OF DUSTING CEILING 340 ANDOVER PARK EAST, BLDG 8, SUITE 600 Date 04/30/08 For Building Department Use 3 NEW 3 WAY SWITCH LOCATION. TUKWILA, WA 98188 Appicant Name: BURGESS DESIGN INC. Applicant Address: 1326 FIFTH AVENUE, X500, SEATTLE, WA 98101 GENERAL RCP SHEET NOTES 2D6587712D i p t int Phone: Project Description 0 New tds1ding ❑ AdeStion ®Aite,ase>n Option ❑ CD Lighting Power Mownnce 0 l Ana (See Qualification Checklist (over). Indicate Rive & LPA spaces clearly an plans.) 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEIUNG PLAN DESIGN. 3, LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCA11ON SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 5. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 7. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED 8. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR PROVIDING CUT SHEETS TO DESIGNER FOR ALL FIXTURES DESIGNATED AS NEW. Compliance ❑ No changes are being mode to the Bghting 12 Lees than 80X of the fixhaes are new and installed lighting wattage is not being increased 33 FIXTURES EXISTING- REMOVED WATTAGE 18 NEW OR RELOCATED = 54% NEW OR RELOCATED =1600 WATTS 10 - 1X8 @ 160W TOTAL REMOVED WATTAGE ADDED WATTAGE WATTS 13 - 2X4 TOTAL ADDED PROJECT 96W WATTAGE =1.248 REDUCES LIGHTING BY 352 WATTS WALL MOUNTED DEVICES SYMBOL DESCRIPTION `.c 2, EXISTING TO REMAIN I=g) DUPLEXX OUTLET ( # DENOTES MOUNTING HT IN INCHES) QUADRAPLEX OUTLET ti DEDICATED DUPLEX OUTLET JUNCTION BOX Ia VOICE & DATA COMBINATION OUTLET ri r>r1r k Ar t I k ITrn r r1 iinrr' I L v u f\ IVI V V I N I L LJ !Jr- V I I., C J IkDO FLUSH FLOOR MOUNTED COMBINATION VOICE & DATA OUTLET AND DUPLEX OUTLET - COORDINATE EXACT LOCATION WITH TENANTS FURNITURE VENDOR. MISC. NOTATION A N DENOTES A NEW DEVICE GENERAL POWER /DATA NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS, 2. ELECTRICAL SUB - CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDI11ON OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDMONS ADDMONAL P /P /D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCA11ON OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. VERIFY ELECTRICAL AND VOICE /DATA REQUIREMENTS WTIH TENANT. 5. PLAN SHOWS LOCA11ON OF NEW ELECTRICAL CONTRACTOR SHALL VERIFY WITH TENANT ANY POSSIBLE SAVING BY REUISING EXISTING ELECTRICAL OFFICE RECEPTI NEW CONF. 609 NEW OFFICE f 608 � NEW SERVER NEW OFFICE REFLECTED CEILING PLAN 0 8' 16' 24' WAREHOUSE f 612 rt4k 1 ,_ Q „ ✓ i r{ ////117,. /L ' //// , // L �'; F / NEW CAGE F 611 POWER AND DATA PLAN 0 8' 16' 24' RECEPTION AorN o r 1 0 KEYED POWER /DATA NOTES COORDINATE POWER, COMMUNICATION, AND BTU OUTPUT WITH TENANT. ABANDON ELECTRICAL OUTLET AT 45 A.F.F. AND IF IN WAY OF NEW PARTITIONS. SERVER ROOM: O3 ABANDON ELECTRICAL OUTLET. LOWER OUTLET TO STANDARD HEIGHT. O RAISE OUTLET TO 44' A.F.F. g LcE D E COMPUANCE PPROVED JUN 1 6 208 C6Y ® f Tukwila BUILDING ®5QN. Tenant: EIS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BLDG 8 610 INDUSTRY DRIVE, SUITE #610 TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design ! interiors Q architecture 1326 Fifth Avenue Suite 500. Seattle . WA 96101 TEL: 206.567.7120 FAX:206. 597.7122 All reproduction & intellectual property rights reserved c 2008 Professional seal No. Issue Description REVIEW SET PERMIT SET REVISION 06/09/08 • ViA Drown by: MK Reviewed by: KK Project No: 08-3402-00 REFLECTED CEILING/ POWER & DATA PLANS Original drawing is 24" x 36". Scale entities accordingly if reduced Date 04/24/08 05/16/08 A.2C.1 CD a DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW s 1 a I, 6" thm 161 a 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. GENERAL DEVICE ALIGNMAENT AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT 12" LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET ,, 7 BOTTOM OF STRUCTU E SEALANT ATTACH GWB TO METAL LONG LEG TOP TRACK CEILING AS SCHEDULED 3 5/8" X 25 GA. METAL STUDS STUDS 0 24" OC, TO 14' -0" MAX. HEIGHT 1 LAYER OF 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS. R -19 INSULATION POWDER DRIVEN FASTENER 0 24 "ac MET RUNNER TRACK SEALANT CONCRETE SLAB NON -RATED FULL HEIGHT PARTITION OS 3" = 1'--0" 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE-71'P. • CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS NOTE PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SECTION 1621 MINIMUM STANDARD PER SECTION 9.6 ASCE7. VERIFY REQUIREMENTS WITH CITY OFFICIALS. 12 GA. VERTICAL HANGER WIRE AT 4' -0" EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE FACT SEISMIC BRACING DIAGRAM NTS ASCE STANDARD 9.6.2.6 For Suspended Ceilings 9.6.2.6.2.2 Seismic Design Categories D, E, and F. Suspended ceilings in Seismic Design Categ'les, E, and F shall be designed and installed in accordan' with the CISCA recommendations for seismic Zones 3— (Ref. 9.6 -17) and the additional requirements listed in this subsection. a. A heavy duty T -bar grid system shall be used. b. The width of the perimeter supporting closure angle shall be not less than 2.0-in. (50 mm). In each ortho oval horizontal direction, one end of the ceiling grid shall b attached to the closure angle. The other end in each horizont 1 direction shall have a 3 /4 -in. (19 mm) clearance from the w Il and shall rest upon and be free to slide on a closure angle. c. For ceiling areas exceeding 1000 ft2 (92.9 m , horizontal restraint of the ceiling to the structural system Lull 1.., provided. The tributary areas of the horizontal estraints shall be approximately equal. BOTTOM OF STRUCTURE 0" 4" / SEISMIC COMPRESSION STRUT • SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8' CONT. FOAM SOUND ISOLATION TAPEABLE MET. TOP TRACK ATTACHED TO BRACING HI /2 SELF—TATTING SM. SSCCREWS 0 48 oc, AND 3/4' PIPE SLEEVES INSULATION UON ON PLANS 3 5/8' X 25 GA METAL STUDS ® 24" OC, TO 14' —O' MAX. HEIGHT. 1 LAYER 5/8" TYPE 'X" GYP. BD. M. SIDE OF METAL STUDS POWDER DRIVEN FASTENER 0 24' OC MET. RUNNER TRACK SEALANT CONCRETE SLAB 3" = 1'--0" 8" 12" NTS 2'X25;12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTEN PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5 -0" OR LESS 2 1/2 "x25 GA METAL STUD BRACING OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTT11ON ACT AS BRACE PLENUM OF 5' —O` TO 10' -0" SHALL USE NESTED OR BACK TO BACK 3 -1 /2 25 GA. STEEL. STUDS. ABOVE 1O' -0" OR PLENUM. CONTACT ARCHITECT FOR ADDMONAL INFORMATION. MAX PARTITION WEIGHT 15Ibs. /P.S.F NON -RATED FLOOR TO CEILING PARTITION 1' -2" a EQ. EQ. EQ. EQ. CASEWORK ELEVATION 'L 2' -1" a O 0 0 0 0 0 ,1 0 0 N CASEWORK SECTION EQ. EQ. PLASTIC LAMINATE DOORS MELAMINE CABINET INTERIOR. 3/4" ADJ. SHELVES W/ MELAMINE FINISH. PROVIDE 1" SHELVES IF OVER 36" IN WIDTH. a PROVIDE P -LAM BACK W SPLASH AS INDICATED ON ELEV SCRIBE TO WALL COUNTER TOP W/ PLASTIC NATE PER FINISH SCHEDULE ADJ. SHELVES W/ MELAMINE FINISH BASE PER SCHED. FINISH FLOOR l > LINE I PL - I P -LAM UPPER CABINETS WITH TWO ADJUSTABLE SHELVES PL -1 JP-LAM COUNTERTOP WITH 4" BACKSPLASH PL-2 LOWER CLOSED CABINETS Wm-I TWO WHITE MELAMINE ADJUSTABLE SHELVES LINE OF END OF WALL -REFER TO FLR. PLANS LINE OF CEILING AS SPECIFIED NOT USED 3/8 "= 1'-0" 1-1/2"=1'-0" DOOR & HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 9 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES, 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.Q.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH - BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE 605 606 607 608 609 610 613 614A 614B DOOR 3' -0' 3 , -0 a 3' -0" 3' -0" 3 3' -O' 3' 0 3' - 0' 3' -0' CD C MATCH Ran DPEA EXIST. A A B A A A A A A 1 2 1 3 2 3 3 3 HARDWARE GROUP GROUP 1 SINGLE, OFFICE LOCKSET NON -RATED GROUP 2 SINGLE, STOREROOM LOCKSET NON -RATED GROUP 3 SINGLE, PASSAGE LATCHSET NON -RATED GROUP 4 SINGLE, SLIDING DOOR NON -RATED DOOR TYPES SIDELIGHT a WD WD WD WD WD WD WD WD WD CD N/A N/A N/A N/A N/A N/A N/A N/A N/A HARDWARE GROUP HARDWARE 11 OFFICE FUNCTION LOCKSET 11.5 PAIR HINGES 1 WALL - MOUNTED DOOR STOP 1 STOREROOM FUNCTION LOCKSET 1.5 PAIR HINGES 1 WALL - MOUNTED DOOR STOP 1 PRIVACY FUNCTION LOCKSET 1.5 PAIR HINGES 1 WAIL- MOUNTED DOOR STOP 2 B/S RECESSED PULLS 1 B/S OVERHEAD BARN STYLE SLIDING DOOR HARDWARE 1 B/S SLIDING DOOR STOP ASSEMBLY WOOD FRAME FINISH TO MATCH SUITE STANDARD FLUSH S.C. WOOD DOOR FINISH TO MATCH SUITE STANDARD cD w z I , WIDTH A I B/S PAINTED WOOD VALANCE WOOD FRAME FINISH TO MATCH SUITE STANDARD SLIDING WOOD DOOR FINISH TO MATCH SUITE STANDARD SIDELIGHT /GLAZING SCHEDULE REMARKS ekp NED FOR t CODE COMP1 APPROVED J i F WI City O G1 MATCH I Exit 48" A 1/4" TEMPERED - WD — G2 36' FAQ 48" B 1/4' TEMPERED — WD WIDTH DU l0 , I 1 WM T100* RFIiAINING SIDELIGHT /GLAZING TYPES CD w A WOOD FRAME — FINISH TO MATCH SUITE STANDARD GLAZING AS SCHEDULED w ca w J 1 H 8 VERIFY WIDTH AFTER HVAC REVIEW boa- Tenant: EIS ANDOVER EXECUTIVE PARK 340 ANDOVER PARK EAST, BLDG 8 610 INDUSTRY DRIVE, SUITE #610 TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design f interiors Q architecture 1326 Fifth Avenue Suite 500. Seattle, WA 98101 TEL:20 &587.7120 FAX :206, 587.7122 All reproduction & intellectual property rights reserved c 2008 Professional seal No, Issue Description REVIEW SET PERMIT SET LL\ REVISION Drawn by: MK Project No: 08- 3402 -00 REGISTERED ARCHITECT Reviewed by: KK Date 04/24/08 05/16/08 06/09/08 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.9.1