Loading...
HomeMy WebLinkAboutPermit D08-310 - INTERLINK SUPPLY - WALLS, DOORS, FINISHES AND LIGHTINGINTERLINK SUPPLY 641 INDUSTRY DR D08 -310 Parcel No.: 2523049008 Address: 641 INDUSTRY DR TUKW Suite No: Tenant: Name: INTERLINK SUPPLY Address: 641 INDUSTRY DR , TUKVVILA WA CitAof Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Owner: Name: LEHMAN SHANNA Address: 2235 FARADAY AVE STE O , CARLSBAD CA 92008 Phone: Contact Person: Name: KIP KOLODZIEJSKI Address: 1326 FIFTH AVE, STE 500 , SEATTLE WA 98101 Phone: 206 342 -0127 Contractor: Name: D P INC GENERAL CONTRACTORS Address: 19909 BALLINGER WAY NE , SEATTLE, WA 98155 Phone: 206 - 361 -2989 Contractor License No: DPINCGC066BU DESCRIPTION OF WORK: MOSTLY DEMOLITION WITH NEW WALLS, DOORS, FINISHES, AND LIGHTS. Value of Construction: Type of Fire Protection: Type of Construction: $80,000.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D08 - 310 Issue Date: 07/01/2008 Permit Expires On: 12/28/2008 Expiration Date: 01/31/2010 Fees Collected: $1,814.55 International Building Code Edition: 2006 Occupancy per IBC: doc: IBC -10/06 D08 -310 Printed: 07 -01 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work, '.1 be complied with, whether specified herein or not. The granting o construction Signature: does not pr rmance of w City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Private: Profit: N Private: Permit Number: Issue Date: Permit Expires On: Public: Non - Profit: N Public: �W Date: 7 ` `0 D08 -310 07/01/2008 12/28/2008 e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development permit. Date: 7/// 0 r Print Name: 7C0e7e La 2 e44.R. i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D08 -310 Printed: 07 -01 -2008 Parcel No.: 2523049008 Address: Suite No: Tenant: 641 INDUSTRY DR TUKW INTERLINK SUPPLY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -310 ISSUED 06/04/2008 07/01/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: Cond -10/06 D08 -310 Printed: 07 -01 -2008 15: ** *FIRE DEPARTMENT CONDITIONS * ** • City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Doors shall swing in direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. (IFC 1008.1.2) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 24: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction doc: Cond -10/06 D08 -310 Printed: 07 -01 -2008 cannot be readily changed. (IFC 1011.5.1) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 31: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 32: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: Each circuit breaker shall be legibly marked to indicate its purpose. (NEC 110 -22) 37: An aisle to and working space shall be provided for each electrical panel. An aisle width not less than 24 inches shall provide access to the panel and 30 inches of working space shall be provided directly in front of the panel. (NEC 110.26(A) thru F(2)) 38: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 39: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 40: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 41: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 43: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at doc: Cond -10/06 D08 -310 Printed: 07 -01 -2008 (206)575 -4407. doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** • D08 -310 Printed: 07 -01 -2008 I hereby certify that I have this work will be complied The granting of t construction or S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us read these conditions and will comply with them as outlined. All provisions of law and with, whether specified herein or not. does not presume to give authority to violate or cancel the provisiat of any other work ance of work. Signature 7 N Date: - / doc: Cond -10/06 D08 -310 ordinances governing or local laws regulating Printed: 07 -01 -2008 Name: CITY OF TUKWIL. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us K►() Company Name: ? Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION � t King Co Assessor's Tax No.: 252-3011008 Site Address: (0'41 lr AJ -• Y E. :we.... R Y 1 6 (1 , 13 Suite Number: Floor: t Tenant Name: t r* 1(' r k r . tc- <J f e ∎ New Tenant: ❑ Yes ❑..No Property Owners Name: Mailing Address: CONTACT PERSON - who do we ontact when your permit is ready to be issued 0 k Z- '' p Sk1 7� Mailing Address: 132.6 ci'1 If\ 1 ►ve • �✓S e. 5U E -Mail Address: K 1 p o� bJ C�P.cS . (?2+ GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping in tarp v r-C�•4 Nall►" e.r (Dl , 6CAMe. ul le 155 City State Zip SR Ve. j Day Telephone: . 2.0(o . 3(01 • Zc S Fax Number: 7-WO • 3102 • .310 lo5 Mailing Address: ten Contact Person: �QitCfi E -Mail Address: Contractor Registration Number: oa Building Permit No. echanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. g 5)) City (For office use only) State Zip Day Telephone: 706 . 34 2... • t ( 2 7 „ S I� vJfl 78101 City State Zip Fax Number: ‘D'Oto • 5 • ',1 2 2 Expiration Date: ARCHITECT OF RECO All plans stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: 3 z. ► ��-In �A gin e- 1 5r` . 500 kK■py. C. to ric.c.s n . ,net neer of Record ENGINEER OF RECORD - All plans must be wet stamped by En Company Name: A • Mailing Address: City Contact Person: E -Mail Address: Q:lApplications \Forms- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh t ea le. , ,413/1 9B (01 State Zip Day Telephone: 2063 • 3 r . • 012 7 Fax Number: Ito . 5437. 1122 State Zip Day Telephone: Fax Number: Page l of 6 BUILDING PERMIT INFORM ION - 206 -431- 3670 Valuation of Project (contractor's bid price): $ 80 jOoO Existing Building Valuation: $ Scope of Work (please provide detailed info ation): D1T� 0 em © C.! r .'nl (AiI .74, it cid a' 4 (f,) pooil 4 ��✓ (Su es Li rta Will there be new rack storage? ❑ Yes P ovide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): NI # Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm X None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Saf tyata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications \Forms - Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh )kKlo If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: ❑ Yes No Page 2 of 6 > xisting Interior Remodel Addition to Existing Structure Type of Construction per IBC Type of Occupancy per IBC 1' Floor I Y 7 -17' 10 (171- /to ,� N/ew / V 9 1Z46 6151 2hd Floor 3r Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORM ION - 206 -431- 3670 Valuation of Project (contractor's bid price): $ 80 jOoO Existing Building Valuation: $ Scope of Work (please provide detailed info ation): D1T� 0 em © C.! r .'nl (AiI .74, it cid a' 4 (f,) pooil 4 ��✓ (Su es Li rta Will there be new rack storage? ❑ Yes P ovide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): NI # Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm X None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Saf tyata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications \Forms - Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh )kKlo If yes, a separate permit and plan submittal will be required. Compact: Handicap: No If "yes ", explain: ❑ Yes No Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Otioaril. AUT . '. " a GENT: Signa �� Date: 6 ` IM ILI Print Name: • �Q7 G1.SL�w Day Telephone: � 4' - ? -7 Mailing Address: 1 3 1.41+ 1 5 1 21 f P ° ctite k) A. 16 19 Date Application Accepted: aofY-1 LIT Q:\Applications \Fortes- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bit Date Application Expires: City State Zip Staff Initials: Page 6 of 6 i Parcel No.: 2523049008 Address: 641 INDUSTRY DR TUKW Suite No: Applicant: INTERLINK SUPPLY Receipt No.: R08 - 02362 Payee: SEISC ENTERPRISES ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 12816 1,101.50 BUILDING - NONRES 000/322.100 STATE BUILDING SURCHARGE 000/386.904 ' TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Initials: WER Payment Date: 07/01/2008 03:29 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts Permit Number: D08 -310 Status: APPROVED Applied Date: 06/04/2008 Issue Date: Total: $1,101.50 Payment Amount: $1,101.50 1,097.00 4.50 4346 07/02 9711 TOTAL 1101.50 doc: Receiot -06 Printed: 07 -01 -2008 Receipt No.: R08 -01935 Initials: JEM User ID: 1165 Payee: BURGESS DESIGN, INC. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 2523049008 Permit Number: D08 -310 Address: 641 INDUSTRY DR TUKW Status: PENDING Suite No: Applied Date: 06/04/2008 Applicant: INTERLINK SUPPLY Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7345 713.05 Account Code Current Pmts 000/345.830 713.05 Total: $713.05 Payment Amount: $713.05 Payment Date: 06/04/2008 11:44 AM Balance: $1,101.50 3234 06/04 9711 TOTAL 713.05 doc: Receiot -06 Printed: 06-04 -2008 Projec ` . I,- r v-- ` A S Type of_Inspecti n: J 1 A.....A. /L 4.X Address: Q i f L/L�t1 v --t 6I Date Called: : .r. Special Instructions: _ / / Date Wanted: 1.. a.m. t Requester: Phone No: �,6 G .... 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. ERMI N0. • CITY OF TUKWILA BUILDING DIVISION )O 310 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: nspector Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 00. Call to schedule reinspection. Receipt No.: Date: COMMENTS: * ∎OrpAli J k4s Avi - Ju-', JAL I 0 i f I ti b k L ). .. 0 'Li V ( Z e,A ‘ I. CI , A-t# el real/ e. A. a rc f u: (t9-EA D i /'r , (( 5t e r4 v ' 1-0 r 2 u/!cr „AA 7 Requester: N _ Phone : . 46/ / - /qa Pn ) Type of Inspection: \J Address: (o LI 1 T 1,104n.Ls. -I v `7 Date Called: Special Instructions: Date Wanted: Requester: N _ Phone : . 46/ / - /qa INSPECTION RECORD Retain a copy with permit D - D( INSPECTIO N0. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION 17 "; 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 '0 Approved per applicable codes. Corrections required prior to approval. r spiEtor: ' f /� 'Date: Q 22 Oe 1 ❑ $60.00 REINSPECTION FEE EQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: COMMENTS: o )) f 1 a r i lei G w l 1 411/ ' . 1 �lrottd Vle 6 11/G Xi AA I Keeclacl 6 OlealleARLeA wu ( 'ieedc4 SOtl ° I l - k. Special Instructions: Cat ro, ,6fsavfiq FW4L /i4 r• Date Wanted: og- m m . Requester: ViP • Zi 1 w �i/e• 7* rad J f ,dvly 7 Phone No: u v® 564 VIM chn PGleV/I-s. --- &t odd t120 . "112# 400 - 714 7 ?tee.rieffe:fill-ae:d eiePtirey. Project: 1 Iv l a i t4 � Type of -F I Nom' Inspection: IY#�1d�. � �. Address 041- INt TRI 1)K, Date Called: - Special Instructions: Date Wanted: og- m m . Requester: ViP • Zi 1 Phone No: u v® 564 VIM WC' a i t 39l- 4l0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit ;ir T -310 PERMIT NO. (206)431 -3617 Corrections required prior to approval. > Dated q_or al a $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proj -- _1-4 rl •;. e Sr54, /c Type of Inspection: ,.S) /sp daEJ Xet Address: _ ( 5// _ 1 --�/d .s% Date Called: Special Instructions: y Date Wanted Requester: Phone No ,.2 3'5/ e5g-c. INSPECTIO NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION it hog - PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 -- g.Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 4- N. (Date: D O REINSPECTION FEE QUIRED: Prior to inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Recejp No.: 'Date: Probe e f CU &Iv_ Sup,P(I;� Type of Inspection: 6,1,A ZiIV Address 1 ( ((moo jar' L. 41A --1 Date Called: Special Instructions: Date Wa t d: It — 1 C — C-D C _ 41-11: Requester: Phone No: V - Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Do6- PERMIT NO. (206)431 -3 7 El Corrections required prior to approval. COMMENTS: pect Date: .00 REINSPECTION ' E REQUI ED. Prior to inspection, fee must be id at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. R ipt No.: (Date: COMMENTS:A C'.DA- ( erE A !.,, JA ' a a Of Airrilif C O 01� - . - e r) 1.. .- • 7 lr'15 / e f . J/l. Special Instructions: 1 e! (2) je,. ( - , ST w ( e v" A i,- . r.( AJJ g.93 A^ Ace Jj 6 ,, �ice .'ei :..S MI(. J 7 e (k_,�1 Lt Jt" ‘/ , )p /jrAeti_ " /) P. / / P -if d ! 13, / ( L 1 (74 {AVf Cam! F.7 t_1` 1-∎ '1 rr £/1 t .2 (c- rinA elt rip r$- :Ai e C_i ,) "' Projects f - }kyLiNk- Sitfl .,/ Type Inspection: t 14 Of We1 Liij Date Calle �p 7 A ress. ■ (04 ( L NC�1►ts {vCI 1 ,' Special Instructions: 1 DatiAantecit � f� a.rrr p.m. Requester: Phone N _ ,,20‘*- - 3c I — e236 - 3 10 INSPECTION RECORD Retain a copy with permit IN PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98) 88 (206)431 -3670 'El Approved per applicable codes. Corrections required prior to approval. lhspecto : Date: s- i r d ,p-" ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 2� COMMENTS: a p I 't'1 , 1dJ� Type of Inspection: to. IA--' i)K -- tU 'L J Cr P \ -00E Date Called: l tiJ0 ILA \ 1 .e t,A3A r> r0 ) Date Wanted: 7 /ate - 3 P.m. Requester: tk. l Ns 90 r` ,),A uAs _S-)try - r N I, f7 Sk) ;r t P' i (- . — P Project: Type of Inspection: to. Address: Date Called: Special Instructions: 7 Date Wanted: 7 /ate - 3 P.m. Requester: Phone 2-0 G -- 3i 1 — 3'.3-co Approved per applicable codes. Inspector: IAA nvk INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION *- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. Date: - - 3 ( n � El $58.00 REINSPECTION FEE EQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: Address: Date Called: Special Instructions: / Date Wanted: -7 - ( �- c a p.m. Requester: Phone No: _ ?,0 6 / 31+ -U At- INSPECTION RECORD Retain a copy with permit /)vs -31v PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. Ei Approved per applicable codes. a 'Corrections required prior to approval. COMMENTS: p l nr1 1.6t 4 Yp /0/. S -- s�P w p•frfW, Inspe tor: (Date: ocAs_i D 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: _ COMMENTS: i 6053 'A''S' i,..1'\U( 6 5 1 ----* ikA b6" L L p A - • 1 — ' 4) /..-i\ J -e) J >r ietNiC_ Date Wanted: - 7 5 i A- f Al I p e.n.ei /4--' i --c z + ( �-y\s 1) 3 pr A. r y C ,is Ocz. , A..x, L A C 7 -C a 7 r Project: Type u { 6053 i t ` e f Address I Date Called: f �,,,, 1.. ,' Special Instructions: Date Wanted: - 7 - / 7 -- a4.m,,, p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit DO - 3' U PERMIT NO. INSPECTION O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspegtor f, i ' A Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: t► re J .- A.r 0. -- I ./ C. E. 0 k'( ) --.! 1J P c.. r W' i f 1.. < c\. ,v Date A.A. x -s ' _•J��� , /b. Nog' ic. ,A1 f/ - i._:.. rac 7I7 473, -ev1 -6 Inal( �� I P14416 -1. n In GS a n L a ices fed *of 61746e5, SJdn rliai anti / -i forded area dog nofexceest ?ce• $r . No7E1 -1.g4 J'T -c■5/e. Lc241t t lid i,N i d -- ratIPTRA AZ t57 / /P iT eSmz)C4.,41 ev E. glr 7 RED t'67Z Proj / , N � 7r r H TYPe of Inspection: l / (o !/ Called: Addr s: �// . J( /2 /s�r� Date Special Instructions: Date W` / anted:: ate. 7 " 6 – p.m. Requester: Phone No: 6 - 3q/ -8c .; INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. Receipt No.: 'Date: Corrections required prior to approval. (Date: 1 ,/ 1 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be ic paid at 6300'Southcenter Blvd., Suite 100. Call to schedule reinspection. Pro a • tLi: % // /* Type of InS ecti n: f Address ; I --- / ?f J(/ Date Calledp ` A J!/� (7 [ Special Instructions: / Date Wanted;_ 7 ' / 4' p.m. Requester: Phone 0 - 3:2/60 INSPECTION RECORD Retain a copy with permit INSPECTION NO. . CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Z6S3/0 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENTS: Inspector: C Date: .7` . � ' �.'' Project: Type of Inspection: de -...'' Address: D ate Called: Special Instructions: / / 4 Date Wanted: ---/— 2# - v a. m p ' Requester: Phone No: 70( • 7 C I - 14 Orr" INSPECTION NO. INSPECTION RECORD Retain a copy with permit 00g _3{ d PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ( 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3fp7 Approved per applicable codes. ❑ Corrections required prior to approval. El $60.00 REINSPECTION FEE R Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Inspector) /k ) ,i 3L Date: ( 1 Receipt No.: 'Date: Project: c hum Type of Inspection: C`MEj� LT Address: 411/ Suite #: ..o- 57c' , Contact Person: Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 proved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY: OF TUKWILA FIRE DEPARTMENT 11U`6 - '2lO PERMIT NUMBERS Corrections required prior to approval. COMMENTS: I; i;x— £7 if t/l� /1 T t1l > odr. � v - O4 -. I ,i - eV--- nspeCtor: s f Z it Date: 2 of rs.. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. 77 - I FIJI ,.d...VII • ..• •• r..v.., . w. . ..■., Project: ',inrK Monitor: Pre -Fire: Type of Inspection: Address: /,'// - Contact Person: Suite #: E-"` Special Instructions: Phone No.: Needs Shift Inspecction: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable cod INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUICWILA FIRE DEPARTMENT 206- 575 -4407 ri, Gac1- Ti iL'wit - Wa UR7 RR ri Corrections required prior to approval. COMMENTS: Lialwn IV (0 -� r o T 14-0 (� I Ft '-d) t4 t, r 'fit t va SAD( J3 v0.^ 4 -c L t , 11 - T iZ-A Hrs.: REINSPECFION FEE REQUIRED. You will receive an invoice from v ila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Project: L me& Sprinklers: Type,.o-f Inspection: A- Address: C. y/ Suite #: "/` Contact Person: 6 & e Special Instructions: Occupancy Type: Phone No.: Ze.4 251 — fVo& Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER COMMENTS: CITY OF TUKWIIA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 pproved per applicable codes. ,-, n DL)I „,, �, � �> - , v vrz 5 L INSPECTION RECORD Retain a copy With permit ot-att /spy Word /Inspection Record Form.Doc 1/13/06 Dr? 3,/,) Ug -c- 3 4” PERMIT NUMBERS n Corrections required prior to approval. $8000 REINSP'ECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. Hrs.: T.F.D. Form F.P. 113 02 -02 -2009 KIP KOLODZIEJSKI 1326 FIFTH AVE, STE 500 SEATTLE WA 98101 RE: Permit No. D08 -310 641 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive -an extension prior to 03/17/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, b Bill Rambo Permit Technician xc: Permit File No. D08 -310 Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director City of Tukwila Permit Division Tukwila, WA 98188 In question to the space being leased at 641 Industry Drive, Tukwila WA 98188 by Interlink Supply of Seattle. Our company specializes in business -to- business sales, and do not sell to the general public. The primary use of the space for this location will be as follows: 1) Front Space- 1/3 of the area will be used for offices and used by the sales personnel during business hours. 2) Middle Space - 1/3` of this space will have multiple uses: a. Displays of cleaning related products on shelves that are less than 7ft high in support of sales staff b. Testing area for small portable carpet cleaning machines to demonstrate the cleaning results if necessary. c. The sales force will be housed in the open office area adjacent to the space. 3) Back Space - The space in the back will be use for general warehouse functions. While the majority of our business is direct shipping we occasionally will ship items from one of our warehouses located in Salt Lake City, Utah or Nashville, Tennessee. While we don't anticipate walk -ins, we may at times have approximately less than 15 walk -ins in a given day, based on surveys conducted at several of our locations across the US. Should you have further questions, please contact me at 1- 206 - 251 -1408 or by email at georse .cazaresfWinterlinksupplv.com Regards, George Cazares Branch Manager CORF�� LTR # TIOdW ,.v� • • interlinksup ply Supplies for the Cleaning and Restoration Professional Dos -310 June 18, 2008 RECEIVED JUN 242008 PERMIT CENTEF www.inicrlinksupplv.com''■ 641 liidutry' Drive, Tukwila WA 98188 • 425- 207 -0149 • 1 - -207 -0149 • 206- 260 -7302 fa. 1,, m - ArraCIIitsv&irt g, v C;u:�0 u>zacuu+ A y G -icir, nrccce June 13, 2008 Kip Kolodziejski 1326 Fifth Avenue, Suite 500 Seattle, WA 98101 RE: CORRECTION LETTER #1 Development Application Number D08 -310 Interlink Supply — 641 Industry Drive Dear Mr. kolodziejski This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator encl File No. D08 -310 • City of Tukwila P:\Pennit Cen ter \Correction Letters\2008\D08 -310 Correction Ltr #I.DOC wer • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo • • Date: June 9, 2008 Project Name: Interlink Supply Permit #: D08 -310 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide specific information that identifies the intended use of the display warehouse. Describe the products that shall be displayed and what will be stored in the warehouse and display area. Identify the squire footage of each open area or space. 2. The plan and building summary refer to the spaces as S1 display warehouse and S1 warehouse. Display retail and wholesale areas shall be classified as "M" occupancy. Mercantile occupant load shall be calculated at 30 sq ft per occupant and warehouse shall be calculated at 300 sq ft per occupant. Revise plan summary calculations and related sheets to show compliance with occupancies "M" mercantile & `B" office. (IBC 306.1 & Table 1004.1.1) 3. Two exits shall be required. The exit doors or exit access doorways shall be placed a distance apart equal to not less than one -half the length of the maximum overall diagonal dimension of the building or area to be served measured in a straight line between exit doors or exit access doorways for a non sprinkled building. Exit access shall not pass through a warehouse or storage area unless demarcated with a minimum 44 -inch aisle defined by a full or partial height fixed wall. Plan shall meet all accessible code requirements for pathways and exiting. Please provide an egress exit plan showing common paths of egress to the required exits. (IBC 1015.2.1, 1014.2 # 2.4, 1014.4.1 & 1014.4.2) 4. Show emergency lighting along path of egress on the reflective ceiling plan. Emergency egress lighting shall comply with egress illumination where emergency pathways have sufficient illumination to meet the 1 foot - candle requirement at the walking surface leading to the exit discharge doorways. (IBC Section 1006 & 1025.8) 5. The site plan is not clear and shall need clarification for parking spaces. Identify accessible parking spaces for this tenant. Show the number of parking is sufficient for this tenant space and occupancy type. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 -310 DATE: 06 -24 -08 PROJECT NAME: INTERLINK SUPPLY SITE ADDRESS: 641 INDUSTRY DR Original Plan Submittal X Response to Correction Letter # 1 Revision # After Permit Issued Response to Incomplete Letter # DEPARTMENTS: Bung sion Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: n REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 OOORD COPY PLAN REVIEW /ROUTING SLIP Approved with Conditions Fire Prevention Structural Incomplete [1 DATE: DATE: Planning Division Permit Coordinator DUE DATE: 06-26 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R TING: Please Route Structural Review Required No further Review Required n DUE DATE: 07 -24 -08 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 - 310 DATE: 06 - - PROJECT NAME: INTERLINK SUPPLY SITE ADDRESS: 641 INDUSTRY DR X Original Plan Submittal ?Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: e 496 1 �I Bui F ing r 'vision ri Pu is Wor s (0-4F) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: O I � i re Prevention Al Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Centel., Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n ❑ Permit Coordinator DUE DATE: 06-5 -08 No further Review Required DATE: DUE DATE: 07-03-08 Approved n Approved with Conditions Not Approved (attach comments) ✓r Notation: REVIEWER'S INITIALS: DATE: s (0 Planning Division Not Applicable n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/ • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7p /P D Plan Check/Permit Number: D08 -3 10 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: INTERLINK SUPPLY Project Address: 641 Industry Drive Contact Person: Kip Kolodziej ski Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on L - \applications \forms- applications on 1ine\revision submittal Created: 8 -13 -2004 Revised: Phone Number: Summary of Revision: P6CGU /O6 /iY,//1G f CGh ' J$ 7 !!�1 l4C$ 774 d �,�rli‘(/ • eta '7/ //C GEC/ 73 / f 0i4X� /t - osr air rim Go VGif 41/0 c- ' ( /EG i6 /S . z./ / �� /'.z z -i/ /d /y.4/./ 1014, z j 05C. /o06 7' /00Lc. red) c //frr, -c., /f / c i Gde7na "i /41664G _ 1D r /" 7)v d>u /aJ j6i) IJSP U/ RECEIVED CITY OF TUKWILA +JUN 24 2008 "F-RM1T CENTER License Information License DPINCGC066BU Licensee Name D P INC GENERAL CONTRACTORS Licensee Type CONSTRUCTION CONTRACTOR UBI 601515833 Ind. Ins. Account Id Business Type CORPORATION Address 1 19909 BALLINGER WAY NE Address 2 City SEATTLE County KING State WA Zip 98155 Phone 2063612989 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/31/1994 Expiration Date 1/31/2010 Suspend Date Separation Date Parent Company Previous License DODSOPI101JB Next License Associated License Business Owner Information Name Role Effective Date Expiration Date DODSON, WILLIAM PRESIDENT 01/31/1994 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 3 • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond #5 Bond Company Name DEVELOPERS STY & INDEMNITY CO Bond Account Number 791078C Effective Date 01/31/2008 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 02/25/2008 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DPINCGC066BU 07/01/2008 GENERAL NOTES 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND /OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND /OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND /OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BAr;KING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLE:S AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. SYMBOLS ELEVATION REFERENCE SYMBOL U DETAIL ID D SECTION REFERENCE SYMBOL DETAIL REFERENCE SYMBOL COLUMN AND /OR GRID LINE SYMBOL DIMENSION LINE: L ANGLE © AT C� CENTERLINE SHEET NO. j INDICATES FINISHED 1 SURFACES TO ALIGN DRAWING TITLE BAR FLOOR ELEVATION SYMBOLS c b 92' -0" -I -1' -0" NOMINAL FLOOR .�� ELEVATION HEIGHT (ABOVE /BELOW) BUILDING SPACE / ROOM ID OFFICE SPACE NAME L 1127 ( SPACE NUMBER DOOR SYMBOL DOCUMENT SHEET SYMBOL DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE �-- KEYED SHEET NOTES GLAZING SYMBOL �--- REVISION NUMBER ADJ - ADJUSTABLE AFF - ABOVE FINISH FLOOR ALT - ALTERNATE ALUM - ALUMINUM APC - ACOUSTICAL PANEL CEILING APPROX - APPROXIMATE ARCH - ARCHITECTURAL ACT - ACOUSTICAL CEILING TILE AV - AUDIO VISUAL BLDG - BUILDING BOT CAB CL CLG CLR COL CONC CONE DEMO DEPT DF DIA DIFF DIM DTL DW DWG EA EL ELEC ELEV EQ EQUIP EXT FA FD FE EEC FFE FIN FLUOR FLR FO FOIC FTIC FURR GA GC GL GWB HC HDW HM HR INCL INFO INSUL LAV LF MATL MAX MDF ARCH / INTERIOR ABBREVIATIONS - BOTTOM - CABINET - CENTER LINE - CEILING - CLEAR - COLUMN - CONCRETE - CONFERENCE - DEMOLITION - DEPARTMENT - DRINKING FOUNTAIN - DIAMETER - DIFFUSER - DIMENSION - DETAIL - DISHWASHER - DRAWING - EACH - ELEVATOR - ELECTRICAL - ELEVATION - EQUAL - EQUIPMENT - EXTERIOR - FIRE ALARM -- FLOOR DRAIN - FIRE EXTINGUISHER - FIRE EXTINGUISHER CABINET - FINISH FLOOR ELEVATION - FINISH -- FLUORESCENT - FLOOR - FACE OF -- FURNISHED BY OWNER, INSTALLED BY CONTRACTOR - FURNISHED BY TENANT, INSTALLED BY CONTRACTOR - FURRING - GAUGE - GENERAL CONTRACTOR - GLASS - GYPSUM WALLBOARD - HANDICAPPED - HARDWARE -- HOLLOW METAL (STEEL FRAME) - HOUR - INCLUDED OR INCLUDING - INFORMATION - INSULATION - LAVATORY - LINEAR FOOT -- MATERIAL - MAXIMUM - MEDIUM DENSITY FIBERBOARD MECH MEZZ MFR MIN MISC MTD MTL N/A NIC NTS OC OFF OPNG OVHD P PART PERF PERIM PERP PLAM PLYWD QTY (R) RA RCP REC REF REFR REL REV RM RO RTD SCFf ED SF SH,T SIr1 S?EC SPKLR SPKR SQ STD STL STOR STRL STRUC SYM M TBD TEL TEMP THK TO TOS TYP UON UPS VCT VIF W/ WC WD W/O -- MECHANICAL - MEZZANINE - MANUFACTURER - MINIMUM -- MISCELLANEOUS - MOUNTED - METAL - NOT APPLICABLE - NOT IN CONTRACT - NOT TO SCALE - ON CENTER - OFFICE -- OPENING - OVERHEAD - PAINT - PARTITION - PERFORATED - PERIMETER - PERPENDICULAR - PLASTIC LAMINATE - PLYWOOD - QUANTITY - RELOCATED - RETURN AIR - REFLECTED CEILING PLAN - RECESSED - REFERENCE - REFRIGERATOR - RELOCATE - REVISION OR REVISED - ROOM - ROUGH OPENING - RATED - SCHEDULE - SQUARE FEET /FOOT - SHEET - SIMILAR - SPECIFICATION - SPRINKLER - SPEAKER - SQUARE - STANDARD - STEEL - STORAGE - STRUCTURAL - STRUCTURAL - SYMMETRICAL - TO BE DETERMINED - TELEPHONE OR TELECOM - TEMPERED - THICKNESS - TOP OF - TOP OF SLAB - TYPICAL - UNLESS OTHERWISE NOTED - UNINTERRUPTED POWER SUPPLY - VINYL COMPOSITION TILE - VERIFY IN FIELD - WITH - WATER CLOSET -- WOOD - WITHOUT DEFINITIONS AND DIMENSIONS A. DEFINITIONS: 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS • IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B, DIMENSJONS: 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. BUILDING SUMMARY . PROJECT ADDRESS: INTERLINK SUPPLY ANDOVER EXECUTIVE PARK, BUILDING 13 641 INDUSTRY DRIVE TUKWILA, WA 98059 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES INTERNATIONAL BUILDING CODE -- 2006 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2006 ICC /ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: ASSUMED VB FIRE RESISTIVE SYSTEM: NON - SPRINKLERED OCCUPANCY TYPE: 'B' OFFICE, 'M' RETAIL & '51' WAREHOUSE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: NA EXIT STAIR ENCLOSURES: N/A CORRIDORS: NA 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 10,472 SQFT '3' OCCUPANCY= 4,648 SOFT; 'S1' OCCUPANCY= 3,454 SOFT 'M' OCCUPANCY= 2,370 OCCUPANT LOAD FACTOR: 100 OFFICE; 500 WAREHOUSE; 30 RETAIL NUMBER OF TOTAL PROPOSED OCCUPANTS: 'B' =46; 'S1' =13; 'R'= 79; TOTAL= 138 NUMBER OF EXITS REQUIRED: REQUIRED 1, PROVIDED 7 MINIMUM EGRESS WIDTH REQUIRED: 44 INCHES COMMON PATH OF TRAVEL: 75' 6. PROJECT DESCRIPTION: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT. NEW PARTITIONS, DOORS, FINISHES. 7. VALUE OF CONSTRUCTION: $80,000 STREET MAP r • ANDOVER EXECUTIVE PARK BUILDING 13: FIRST FLOOR AREA OF---\1 WORK - 2003 SITE oC`' No changes s9 oe made to the scoop of work without prior a pproval of E:3, , k. _Tukwila Building Division. NOTE: Revisions will roquiie t eW p and may ;ncl! de additinra1 Oran SEPARATE PERMIT REQUIRED FOR: (Mechanical Cffli Electrical Ivmbing Gas Piping City of Tukwila X X X x X X X x X X X X KEY PLAN / FLOOR PLATE - 1/16 " = PROJECT TEAM TENANT: Interlink Supply P.O. Box 6267 Seattle, Wa 98064 ATTN: George Cazares ARCHITECT /DESIGNER: Burgess Design, Inc. 1326 - 5th Avenue, Suite Seattle, Washington 98101 Tel: 206.587.7120 Fax: 206.587.7122 ATTN: Kip Kolodziejski BUILDING MANAGER: REIT Management and Research LLC Andover Executive Park, Building 9 617 Industry Drive Tukwila, WA 98188 Tel: 206.575.6675 x303 Fax: 206.575.1415 ATTN: Loretta Alake SEE SHEET G.0.2 DRAWING ISSUED CO aD a 1i In CO 0 0 PARCEL NUMBER: 2523049008 DRAWING INDEX as NO SEPARATION REQUIREMENT BETWEEN 'B' AND '51 PER TABLE 508.3_3 GENERAL CONTRACTOR: DP Incorporated 19909 Ballinger Way NE, Suite 101 Seattle, WA 98155 Tel: 206 -361 -2989 Fax: 206 - 362 -3665 ATTN: Terry Spivey 500 PLUMBING ENGINEER: TBD - Bidder Design GENERAL ARCHITECTURAL / INTERIORS A.1.1 DEMOLITION PLAN A.2A.1 CC NSTRUCTION PLAN A.2B.1 REFLECTED CEILING PLAN THIS OPEN OFFICE AREA HAS 25 OCCUPANTS Build by G.C. MECHANICAL ENGINEER: TBD - Bidder Design Build by G.C. ELECTRICAL ENGINEER: TBD --- Bidder Design Build by G.C. FIRE /LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. LEGAL DESCRIPTION / PARCEL NO. fieE COPY G.0.0 COVER SHEET / PROJECT INFORMATION G.0.1 PROJECT NOTES G.0.2 SITE PLAN r►Iloi PCs Permit No. Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation . R adopted .:i, e or ore. R slot at appro - . . d; opy ar ca • ditions is ac low tad: .Ar►fy w .rte R A.9.1 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS RECEIVED JUN 242 -' ERMIT CENTER • • Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design interiors p architecture 1326 fifth Awing Suite 560. Seattle . WA 88101 TEL: 296.587.7126 FAX:205. 587.7122 All reproduction & intellectual property rights reserved c 2005 Approved by: Date: Professional seal PPROVti Jul 2t; 2O8 C PERMIT SET Ltd REVISION 1 CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL. BE INTERPRETED AS APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT EQUIPMENT AND FURNITURE INSTALLATIONS. CONSTRUCTION AND /OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS, SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS. BY BOTH 'THE BUILDING OWNER / REPRESENTATIVE AND THE TENANT. No. 'Issue Description REGISTERED ARCHITECT KOLQDZIF STATE OF WASHINGTON 7796 Drawn by: MK Reviewed by: KK Project No: 08-0147-00 Date 30 MAY 08 23 JUNE 08 COVER SHEET PROJECT INFORMATION Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.0 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN /BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. DMSION 1 - GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON- STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UON. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL 50 ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR (5 RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE /EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE /EMERGENCY SYSTEMS AS REQUIRED BY ALL APPUCABLE CODES. FIRE /EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUIILDING SHELL STANDARD SPECIFICATIONS. 11. VERIFY ALL BUILDING CONSTRUCTION RULES WITH BUILDING MANAGEMENT. 12. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDmONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 13. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 14. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOUTTON WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOUT1ON OF TELEPHONES, ELECTRICAL, VOICE /DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOU11ON OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH ". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSIO H - A RCHRECNRAL CARPEMRY AND MEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB. /CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE: HIGH- PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL - PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY', UON. 6. SHELF EDGING TO BE VINYL, UON. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE - MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 5. CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRM QUANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1 -1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLJCATION MADE. 08810 - GLASS 1. ALL GLASS AT SIDEUGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. DMSION IX - FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M /R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI - EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING /PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBUES. 09500 - CEILING SUSPENSION SYSTEMS 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEIUNGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR UGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY AUGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF' 1/8" IN 12' -0 ". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDMONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEW CEIUNG TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCONTINUITIES IN THE CEILING WITHIN 10 DAYS. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 09650 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER - REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12 ". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10' 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 09680 - CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE UGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B " CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3 -B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH -UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 9. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES CI PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. DMSION XII - FURNI, H�IN,,GS 12500 - WINPOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDmON. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI - BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. DMSION XV - MECHANICAL 15400 - PLUMBING . 1. PROVIDE SUPPLY, WASTE AND VENT ONES, VALVES, FITTINGS, ETC. REQUIRED FOR - KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS. 4. PROVIDE HOT AND COLD WATER TO SINKS /DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15500 - FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A -10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLDCIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER UNES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 15800 - HEATING VEUBLATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR C OMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS FILTERS AND THERMOSTATS. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA C ABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER UNE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED' GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, " EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, C OMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT UM FED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDEUNES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLJNE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK -TO -BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT j BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN /BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO I NSTALLATION. 1 9. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN /BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT L OCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER /DATA, FIRE .SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINIISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER /DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS. 16500 - LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEIUNG TILE, UON. 4. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 5. PERMIT DRAWINGS TO BE REVIEWEID AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 30(0 SQ. FT. ENCLOSED BY WALLS OR CEILING- HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF UGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. CONTRACTOR SHALL RE- CIRCUIT AND RE -SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE 1TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEIDED. RECEIVED JUN 2 4 2008 PERMIT CENTER Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design f inte riors architecture 1326 Fifth Avc11uC Suite 500 . Seattle - WA 88101 TEL 206.587.7120 FAX:2o5. 587.7122 All reproduction & intellectual property rights reserved c 2008 9 Drawn by: MK Professional seal No. Issue Description PERMIT SET 7196 REVISION 1 23 JUNE 08 Project No: 08- 0147 -00 REGISTERED ARCHITECT � KIP :17;;;;IN O Reviewed by: KK PROJECT NOTES Date 30 MAY 08 S3IC Original drawing is 24" x 36 ". Scale entities accordingly if reduced G.0.1 •••■71:malt=7,172 • e " 7L 40" % . 317 7,5? ! f • . ;kr- f 2 • *1.. • " 71' • • , ` 4 7 5 ,P • ' . • • t=4*- Maki p ... A c DRY V.& ••;,- v.- • ,. • = :57° s .77 • / ,•• 4c1: r rpi -`•2 ";:` • • ••• F-sP • •1 •%. 7 3: • - • 0 / I.:" l '---•:,• ( -.N..:,! . 's.' '.." " . .i , ;" ,e .• :: 0 sl '•-■ l-.• , • .• .,.. • • • . • -•„. • ,•••• • , e ti r ""?•! 1 • -• •••••,..1 - 6 kV *11 Ir" 1 4 -L... ^ C • - .1"`" As I ' q ,m ,1 -- g ' ----'' ..w.li - , -,,,.. • i . i i, --... ---,,- g: .: r. ,er_, „ .7•„.: --,.? c.,., --.. !-- • -a- •5; • •11" i.., if --ug ..4.-9•4; ' ., 1 -"...""• -"=.7",7" :I. S • ,,,„..- .• . -,•• -•-• 315 5,,. I l t La: ' e - F ., -,,,,,, 5`• "3 . ., a 1 :,,,,, - 4,1. . • -, a ,r :,„.a,_ , r5 . ..V." ‘4.4.2,,,_ II L-:-' • •- .-k , - k'll,'2„,- ; -..,--• - ,.„, i,. , .,..•„ r - . "" e • • •,4 " 554 7-7.7 •;;• tr"t ggytigarm r • ••t-• 4 ..";' [ cz I ,T5 j„Il e s lk•AiLig • '', • . •; A tX %"•An. 11.^' "c• ee 2 AF,.; A I. L • - • • • _ 1 • -• • ' • 7,,s...‘" • "•-s••••zi; • r • = •••- .4.71! •••• •,;.° • • 015 , .7 • ::i ••••T ""- • - °' a p • 7L. 37.2:9111:::" • 2! • •;••■•• s • • " • R '1.5 • " 7 • A • t •1` • 404 ▪ • 1".. • , •4°.i • l•-%1. trP i•? - ' 5 • - .. ''\ '',',..., .4-A7L,A0„ "\- ,... -1. In A %.• %• ••••, " • - „ •5 r • • Al' „•,• `vir •1 7A, • *,14:-.3,;,••• .• 4 1, ▪ 1: 4 ! . • .7 !• 5 .; .- ••; - _.° • 1 fr E ti.-•= 1 . • '"'• 37 ".E,I; e•!„.•7. r.•1: ; N • - . J r • .r."7" a - • • /.1 1; - •• "...:N r% • • • -,•• 4 • ee !?'"5. • V*21 t r *. . . r 52 1 "' 21' „ . ,... A - . - . r 41- ' Y'.41 --- i;• ... :,. ,.. ig •• r 1 • • '. , ' 1.4% ' , ..1 ..; ...L. s . ' 761 1" -'., , rit j j. ! ( . : , k .... . T:_ _ • ',..1' i• .;.- •.,"- „ _ % '. - F- •• . ' s 777:: N. . . 11 i ,,,, 4 ....._ ,.. • T , ,.. 4. . ■ m .* 'n.T1 • 1 •‘ ' ". :•. • a•( -• •= ••!°•••''' r .. ' ; ' ; • ' ... 5 -* E' J. ' . 9 ' rtrY . .: % .. • ..' ' ..: r : '...• r . ' '' r .'", ' . ; , • „„ • s • .• • • , • ,,;•%•3'" 40" ,••• ,..-0;77 • •=• ;:;•• 2 • - - . „;4• • X- 21° ` e• "•••••••• e: L7/;>,- • • ii" 71 - •t•l • r„, . • , Akr r .;- •3, % 3 • 0C,N% 2"7N. 1 ; s•-• • r • • eVs..7.-"! .° ,.-- • 5.°■.7 • "77LS".mie'l '.1-4(.- 7 , • • - ; • -•.‘,.• • .P■ e • • SITE PLAN - NOT A LEGAL SURVEY 11 P NTS 0 '' "•. •-.1 • " %,lea • • :.t .• • a r • . - _ \ • e r• al5." • • • • ' 2;12 • = „• • • • 'I 7 N. • -•-,. e 41 7 • „e -•. • " --• • FA• ik n• • • : • 1:"■ ▪ ;;;74:•:. 'fr .! 774; • ,.=„ 2• 1 •;" . ." 7 • • • X. r r 7" itz&d=. 9 r • , • - • ! • %•-• N7? z ' ; • .• .• 17' .4. 4 7 • . • • 7 t; • • • - - ` 4 7 • zm 1" ;1 . :„E 1'7 • if • .7 . " .°4 • , ' F 2 • - 1 4 J.5. " • • • .".°1Z, • •-• • t•'!, n ••••• • •.;.• ;, • •D` .k•f:N.. • " . • , it..? • - •"% ". ," ••. A ije ;" •• cr • 41•'• • ‹..? • ••• • • ' • ' ea, $24 •-", r .11 r e• 4 0 ■ P ,re .3,` ... • . B.41161, ▪ riszel 117". •IP •": 4` A"f,: ••••• 4". e C;:a - „e :Fa • \ .3,, • • 0 tf I • • - '" 5 !" 't , • s • 7 • e5.3Az, RGE, 4E. W44. • • • • 1. I • „:• 5 • •• • • • r 17 - r -7 71 1 .;•, r • L .V-C4* sa; ,r • --e• - •-. e 5.35 ▪ '4 " • ' " s pleiALLT - • ;. ° . ft ▪ • •• • , 74 • , -4 „ • . a ! . . i.. • • #t" ▪ h - •74 ft V (--%1 • ..-• -•.••• V 7' k. • T s ▪ •••• • • s•-• - • . .„ .• • . " * ' •:R=.04:• • • - ' LI •, • / ...q 9 , j ,.. ".*- • / ° L • ? - ; .' .V 14 ., .. I, . M ... II f • . ,.. :. • •,. , E , • . "'AEI. • .1 " ' ••4 ::. I • ./.? • - ..F I P A ... „• 7 ' • : '`. :. ''.. •- %.. , y e , m .1 • ,.. r. '' ' aim ' . ke ■ .-..* .--%'„,, ,- ....- . • : ..‘, ,, = 11 = , • . • .... .• , " • . , "L,". „ 7. 11 ' '• 'A ; 0 : • 0 , . a• ferl: • : a-A.4LT• :•••7' ••••• a.. . ; b : ./7 • • • " - s •5,-C : A '''n• t • BC,Oi:3- Jo 6 - - ..= \ - • - s „ „i• AR T* • .77 r n : 1.44.: • ▪ ' J.,: `‘. :72= • Jr "...% *r■l• • . 7 6 kir 11' : - U • a ▪ • • 2'. rai • I ;'•\ -re .•-•:„. • • • %..-••••..- ▪ • • . . :. ."; g • . .- --:- - 4.1..m.. • : ...,•: .... .-- ,e-c= - ,., , 2 ss. , ,,,s ., • . I- › a i- :.'-.,_:•,'"i' Yng":=2.114 2 ../.e %. 7.:171-9! / -/ ..7.L . - 1 lfm • 351 . • • 187 '' .i' r O AN ';!., / 4.- - -• ,. . .s ." . ••;!, •, ••.. . F g' '- IA: . •,.... o 3- 22,..o --,„ ... '-'IC• ' . 11! ." • . •A ". , t %e / ' 1 - , ..11, 0 ..,i' • - _ i : . ',..... , . ..0' •,„ =,1 - .0". 4 . A 1 • 4 ' • • • r ' .• XI: e • e • • • 50. '" .' •`• 4 V • °..."..".q % A• %.•-••• 'T% e.„ • ru g ! fraV • " • ,,g of dJ.iIL dr ° - 7° ek 5 ' ." • A wr •• • • • • • ge • = • : • ' - " Pe4A4521. ? / 4e • • " • rne r . • 71.- ,r,1•3 • • e :7.. • 7 . • . ' • • • ' ,••••' 4 4: 2 . . ° " - • " ;.• 7ez. _ 2,1 X *:7;it'g •;.` ' • a r. •-•• • " '^' 'eT ...!% • 't? • -1 b"" iL - • • el, 'SEP 7\7'. . • • . :7 - • -0" ;"..7 • • : 4.40.1?Anii":".0d • r • s ?=4 a ..721 • " (Fr .r -N 7' 4; -,e r.f07.1%WPANVa. 6 - 4 1 1.: 4 0 - 01 13 1 r 40' k a 1 ' • V*7) K..C• N:ta J 4 1 41',7 - .7r AO 47.' .;fa .'erc.za,N ,' Ort 1 z7fir t" ;TesKit gr ir Ile 2' C. • • • 4 . , • • 2 X r t ,h52:so." L S? .A.T11 rPtch.AL FRO NT _COR.N.gR in 41:, t-1-1,013: AM) 4.E6AL„Da" atle ;_c-O.R.CEL n■44••■•... AvAnolif -E4-7 HE rar.17! r4Z ff‘gtiCriathr4 i AS j •q ..recizot L 1 y 77:edogrH4 L3 A•'0114 •EG01,9F; 1 .4 i° 'T01: kw-wink; Ar iw T e4 Ea:LAVER szoluee •- rmizeitg- iVV-4' 174 s E12.8,4g '!urliWIT g/f§s4r6 F•4 L7 41k7C7nloi -EP' Jr's AfeY.761,rsie 7 As4 CL-P 24aafed "ar2 t"a? °47' FfE4 Fa it ; WC „q, exv.gra Red•R: 6 RADtELc rl." wales!. irm TTA-7 .!4 c r AtAkar -1-G !;I! AWL 1 itg! 0..141:46E6 :371-..EWa • to9 r e.44 04 FE ri rotH4s6 .40 gLigke . fteea• rWri' Hiiik•WYMI. 10:4061:AS k* "Pa aa FEET' Z.FIMAtV--SSi , e2N - reMit 4.•5Le '* M "Seit5L Agg' 4- 404r r a 41 A .e.W5 EIRAMM7.4 3�T •w FoEf.rikife:4 Itai.ir,q este .54'",W'"i'.$1,tr Azaigh, Sl" toelf oVitIttir xr•r• rtIfFiNrce. sturhi 41 27.1" 6 AcIdi 0..61 1 t ediWee S 411 'P' 'I lffoi87 9 9 Ft, FATE tei"E'5k. TERI2ir r AteA 12 OS '13 17 OA AM CAW eSTEWS ' 4t - c% g : el PI 5 • rH40AL wants icerr p-eawciE 1 Mr28r 132 4? Autrivatil Ata:01W .t6 fr 4- 4E-ST ERd- NetuR d7 Ftr FAZ:1 'V•j1 ariTET j 771AS' fiCriArr B AW:t1172‘ r r t • 'AA A N D : : 2 . 1 7 4 0 1 . 4 1 1 . r . g : 0 3 7 : ) , P c rirtriE ir RiA2•*; .7E4 R Atefa ISA S EME N 0.e 4,2tult ; ogr rsie ex.)wed r AY-l•id s rot. ra3 LTA 0 011e.At (51;€019: • E• aaszy-t „TEN -Ae-A FIT gr.)! 1-M5iS • . ENLARGED STRIPPING PLAN A.A r • KEYED SHEET NOTES • NEW 48" CURB CUT, SEE L/9.1 <> NEW ADA PARKING ACCESSIBILTY PARKING LOT STRIPING. • NEW ADA PARKING SIGNAGE SEE DETAIL c & G/A.9.1 ADA COMPLIANT CURB CUT. SEE L/A.9.2 PROVIDE NEW CONCRTE PAD FOR NEW EXIT DOOR. LEVEL AS NEEDED PANT OUT EXISTING STRIPPING EXISTING STRIPPING ADA SGNAGE, SEE C & 0.9.2 far4P• 1,kA 4•••• • 1 •I , •••••••. . • 3/8"1'-0" IRFCEIVED Lim 2 4 'tHIViT GEMS Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design 1326 Fifth Avenue Suite 500 5a ttle • WA 68101 TEL. 206.587.7120 FAX:0.57.7122 All reproduction et intellectual property rights reserved c 2008 Professional seal No. Issue Description PERMIT SET int e riors c;:i architecture • REGISTERED ARCHITECT e" Avel KIP G. KOLODZIEJSKI STATE OF WASHINGTON 7196 REVISION 1 23 JUNE 08 8 3 I 0 Drawn by: MK Reviewed by: KK Project No: 08-0147-00 SITE PLAN Date 30 MAY 08 Original drawing is 24" x 36. Scale entities accordingly if reduced CO DEMOLITION PLAN Fr 1/8" = 1'— 0" 0 8' 16' 24' DEMOLITION SYMBOLS _ _ EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE ALL LIGHT FIXTURES, D(rr SIGNS, DOORS & HARDWARE FOR RE —USE, UON. 3. SAVE ALL COSTING PLUMBING FIXTURES FOR RE —USE, UNLESS OTHERWISE NOTED. 4. REMOVE ALL TELEPHONE, ELECTRICAL AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. 5. REMOVE ALL FLOOR AND WALL FINISHES EXCEPT FOR EXISTING ROOMS NOTED AS NOT IN CONTRACT OR OTHERWISE INDICATED IN THE KEY NOTES. 6. REMOVE ALL INCIDENTAL EQUIPMENT FIXTURES AND ASSEMBLIES IN AREA OF DEMOLITION. 7. VERIFY ALL ELECTRICAL, PLUMBING AND HVAC DEMOLITION WITH TENANT. KEYED SHEET NOTES �1 DEMO DOOR, FRAME, AND HARDWARE -- TO BE STORED OR RELOCATED AND REINSTAll.ED WHERE APPLICABLE. VERIFY WITH BUILDING MANAGEMENT. • DEMO UPER AND LOWER CASEWORK. PATCH AND REPAIR AS REQUIRED FOR NEW FINISHES. O DEMO EXISTING VCT. CONCRETE FLOOR IN DISPLAY/WAREHOUSE AND WAREHOUSE AREA TO BE PATCHED, REPAIRED AND PREPARED FOR PAINTING. REMOVE ENTIRE CEILING ASSEMBLY. O REMOVE CONCRETE PLATFORM. a REMOVE STORAGE CATWALK. • NO WORK IN THIS AREA • ABANDON ALL ELECTRICAL IN THHIS AREA. REMOVE DISPLAY. 1O REMOVE ALL EMPEDANCE TO EXITING AT THIS EXTERIOR DOOR. bO8 3IO L RECEIVED JUN Z 4 2 • JERMIT CENTER Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design interiors ®architecture 1326 Rflh Avcnuc Suilc 500. Statue . WA 98101 TEL: 206.587.7170 FAx:206. 58771 ?2 All reproduction & intellectual property rights reserved c 2008 Professional seal No. Issue Description PERMIT SET Q REVISION 1 DEMOLITIO 7196 KIP G. KOLODZIEJSKL STATE OF WASHINGTON Drawn by: MK Reviewed by: KK Project No: 08 0 147 --00 \I PLAN Date 30 MAY 08 23 JUNE 08 Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.1 .1 DEMOLITION SYMBOLS EXISTING CONSTRUCTION TO REMAIN NEW INSULATED INTERIOR PARTITION CONSTRUCTION, PER DETAIL K /A.9.1 NEW INSULATED NOON RATED CONSTRUCTION TO DECK ABOVE, PER DETAIL J /A.9.1 GLASS W/ FRAME r FEC —E /N NEW OR EXISTING FIRE EXTINGUISHER; E = EXISTING; N = NEW GENERAL CONSTRUCTION NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDfONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL /CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. PARTITIONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. CLEAN AREA WITHOUT WORK AS DIRECTED BY TENANT. ELECTRICAL /VOICE DATA NOTES 1. ALL ELECTRICAL, VOICE DATA REQUIREMENTS SHALL. BE VERIFIED WITH TENANT. 2. RELOCATED SUB PANELS FROM DEMOUSHED WALLS AS NEEDED. HVAC /PLUMBING NOTES 1. ALL HVAC AND PLUMBING REQUIREMENTS SHALL BE VERIFIED WITH TENANT. KEYED SHEET NOTES O ALIGN NEW DOOR JAMB WITH EXISTING COLUMN. PROVIDE 4° JAMB SPACE. CONCRETE FLOOR IN DISPLAY/WAREHOUSE AND WAREHOUSE AREA TO BE PREPARED FOR PAINTING. SEAL PENETRATIONS AT DEMISING PARTITION. O NO WORK IN THIS ROOM. O PROVIDE GWB ON ONE SIDE ONLY:. (NOT FIRE RATED) 0. SET PARTITION AT MIN. DISTANCE FROM JAMB AS NEEDED TO PROVIDE ACTION OF EITHER DOOR. 70. ACTIVE LEAF. 0. EXISTING SPACE HAS WALL AND ROOF INSULATION. NEW PARTmON SHALL HAVE R -19 INSULATION IN CAVITY. HVAC SHALL BE REWORKED TO IMO AND WSEC CODE. PROVIDE AIL HARDWARE NEED FOR LEGAL BONG. • VERIFY OR PROVIDE PASSAGE LATCH SET. FINISH 1. SEE TENANT FOR ALL FINISH INFORMATIION. RECEIVED JuNZ PERMIT CEVIER GVUU 1LK- 1U14.2 Exception L AN EXIT ACCESS SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. REMOVE ANY LOCKS TO PREVENT LOCKING OF TIIESE EXIT ACCESS DOORS. AISLE SHALL BE KEPT CLEAR FOR EXIT ACCESS A MIN. OF 44 INCITES WITHIN THESE OFFICES. LUDO t in-1 U 14.Z Exception L item S. AN EXIT ACCESS SHALL NOT PASS THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. REMOVE ANY LOCKS TO PREVENT LOCKING OF THESE EXIT ACCESS DOORS. AISLE SHALL BE KEPT CLEAR FOR EXIT ACCESS A MIN. OF 44 INCHES WITHIN THESE OFFICES. (E) n CONSTRUCTION PLAN 0 8' 16' 21' CAGE 108 NEW WAREHOUSE 1 107 j (E) (E) (E) Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design I interiors Q architecture 1326 Fifth Avenue suite 500 Seattle . WA 89101 TEL: 206. 597.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2008 Professional seal No. Issue Description PERMIT SET �1 REVISION 1 REGISTERED ARCHITECT KIP G. KOLODZIEJSKI STATE OF WASHINGTON 7196 Drawn by: MK Reviewed by: KK Project No: 08-0147-00 30 MAY 08 23 JUNE 08 CONSTRUCTION PLAN Date Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.2A.1 0 0 0 OFFICE % ∎■-■ i olocl d 11 4) ❑ O - — tosimm. =ENE mom Eliorztr, minimirmr --mmaidirA TYP A 1 J ■ i _ c4. r ri IL„ fro Elm IarAl la milk> EN mum 1�1 • om 0.►® m■ • m o o 109 ■ N 7' - 0" N N 3N N 1 N N 1 1 N N 0 3N 3N REFLECTED CEILING PLAN 0 8' 16' 24' CAGE 1 108 N NEW WAREHOUSE x 107 N NEW DISPLAY 105 N co R r 1/8" = 1' 0" 0 N r 0 r J N 0 1 J N N 0 N 3N R N PM = = i GT �iI ■ O 0 _ _ _ ■ I,..i MI MIN =I ru ITOMM■ V tr Q IjL Q Nom .INANisara CD ■1.� . i I Mall ® • I� [a7�l�Imom �r i-- �1 V ° I OFFICE E - Mil � � _ 0 I 1►/ !!III ►�■ M■ �1 ■N\ OFFICE • MOM= = • 115 I�� ® �ll 11111111111111111= 102 ■� Lta l� ® � ..__.,. . II� .■ nib 104 ■ �r • Immo NE __ i �� 7Cd7 m■ ■e � �wd me■ 'B' OFFICE AREA NO CHANGE TO UGHTING 'S1' AREA HAS NEW LIGHTING CALCULA11ONS 3 LIGHTING SUMMARY 2004 Energy Code Compliance Form LIGHTING SUMMARY LTG -SUM 2004 Project Info Proles Address ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILLA, WA 98059 Applicant Name: BURGESS DESIGN INC. Applicant Address: 1326 5TH AVE, SUITE 500 SEATTLE WA 98101 Compliance Option Applicant Phone: 206.587.7120 Project Description Aitara6an Exceptions (check appropriate box) Date 05/30/08 For Wilding Department Use ❑ New Building Addition IYl Alteration O Prescriptive ® lighting Power Allowance 0 Systems Analysis (see Quarlficotion Checklist (over). Indicate Prescriptive & LPA spaces dearly on pans.) I No ctsonges are being made to the lighting ❑ l.esa than 60% of the throats s are new and installed lighting wattage is not being increased CEILING LEGEND -- LIGHTING SYMBOL R R R DESCRIPTION /SPEC SYMBOL EXISTING 1' X 4' FLUORESCENT FIXTURE; 2 TUBES; TO BE RELOCATED EXISTING 2' X 2' FLUORESCENT FIXTURE TO REMAIN EXISTING 2' X 4' FLUORESCENT FIXTURE; 4 TUBES; TO REMAIN EXISTING 2' X 4' FLUORESCENT FIXTURE; 4 TUBES; TO BE RELOCATED EXISTING 2' X 4' FLUORESCENT FIXTURE; 4 TUBES; RELOCATED EXISTING 1' X 4' FLUORESCENT FIXTURE; 2 TUBES; TO REMAIN EXISTING 1' X 4' FLUORESCENT FIXTURE; 2 TUBES; RELOCATED N NEW 1' X 8' FLUORESCENT FIXTURE; 2 TUBES EXISTING 1' X 8' FLUORESCENT FIXTURE; 2 TUBES; RELOCATED 'EXISTING 2' X 8' FLUORESCENT FIXTURE; 4 TUBES; TO REMAIN DESCRIPTION /SPEC EXISTING RECESSED CAN LIGHT TO REMAIN. EXISTING SMOKE DETECTOR FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. EXISTING EXIT SIGN TO REMAIN. COORDINATE WITH CODE OFFICIAL. NEW OR RELOCATED DIRECTIONAL EXIT SIGN. COORDINATE FINAL LOCATION WITH CODE OFFICIAL. EXISTING I-IVAC SUPPLY FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. EXISTING HVAC RETURN FOR REFERENCE ONLY, NOT FOR DESIGN INTENT. NEW EXIS11NG 1' X 8' FLUORESCENT FIXTURE; 2 TUBES; TO REMAIN EXISTING 1 X 8' FLUORESCENT FIXTURE; 2 TUBES; TO BE RELOCATED RELOCATED "V "Nor Y Y EMERGENCY PATHWAY LIGHTING ..... Q 1 CEILING LEGEND -- CONTROLS SYMBOL DESCRIPTION NEW SWITCH LOCATION NEW NEW THREE -WAY SWITCH LOCA11ON GENERAL RCP SHEET NOTES 1. SEE DEMO PLAN FOR ADDITIONAL INFORMATION 2. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 3. ARCHITECTURAL REFLECTED CEIUNG PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD UFE SAFEIY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 4. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCA11ON AND SWITCHING DIAGRAMS. 5. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE. 6. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEIUNG GRID AND TILES EXISTING TO REMAIN. 7. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY /RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 8. ELECTRICAL SUB- CONTRACTOIR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES TO BE RELOCATED. 9. ALL UGHTS ARE BUILDING STANDARD OR MATCH EXISTING. 10. MATCH NEW HUNG LIGHT HEIGHT WITH EXISTING KEYED SHEET NOTES • NO WORK IN THIS ROOM? 2O RE- CIRCUIT SWITCHING FOR NEW LAYOUT t� (C)F O PROVIDE GWB SOFFIT 1" BELOW EXISTING ACT CEILING. 4a INFILL GWB PARTITIONS AT HEAD TO ENCLOSE CEIUNGLESS AREA. VERIFY WITH TENANT 5O DIMENSIONS APPROXIMATE VERIFY LIGHTS DON'T CONFLICT WITH DOOR; RAISE IF NECESSARY REVISION NOTES 1. EMERGENCY EGRESS LIGHTING SHALL COMPLY WITH EGRESS ILLUMINATION WHERE EMERGENCY PATHWAYS HAVE SUFFICIENT ILLUMINATION TO MEET THE 1 FOOT- CANDLE REQUIREMENT AT THE WALKING SURFACE LEADING TO THE EXIT DISCHARGE DOORWAYS. (IBC SECTION 1006 & 1025.8) 2. EMERGENCY LIGHTING IS JUST ONE TYPICAL SOLUTION TO SOLVE EGRESS PATHWAY LIGHTING. Location (floor /root na) MAXIMUM ALLOWED LIGHTING WATTAGE (INTERIOR) LaaaUon (floor/room no.) FIRST FLOOR FIRST FLOOR Occupancy Description 'S -1' WHOLESALE STORE 1 5 -1' WAREHOUSE Allowed Watts per S.F." 1.3 .5 Area in S.F. 3,348 3,100 Allowed X Area 4,352.4 1,550 From Table 15-1 (over) — dawned el exceptions token from footnotes Total Allowed Watts 5,902.4 PROPOSED UGHIING WATTAGE (INTERIOR) (Wry not exceed Total Mowed Wafts for Interior) Fixture Description Number of Fixtures Watt/ Fixture Watts Proposed FIRST FLOOR FIRST FLOOR FIRST FLOOR FIRST FLOOR WHOLESALE STORE 1' X 8' EXISTING AND NEW WHOLESALE STORE - 1' X 4' EXISTING AND NEW WAREHOUSE - 1' X 8' EXISTING AND NEW WAREHOUSE - 2' X 8' EXISTING AND NEW 23 24 120 64 120 160 Total Proposed Watts may not exceed Total Allowed Watts far interior Total Proposed Watts 2,760 64 2,880 160 5,864 bOB(O RECEIVED :Jr-4 42 l'r' �Ir� 1 CENTER Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 burgess design interiors © architecture 1326 Fifth Avcnuc Suite 500. Settle . WA 98181 TEL: 206.587.7120 FAX:206. 587.7122 All reproduction & intellectual property rights reserved c 2005 Professional seal No. Issue Description PERMIT SET 'cAe! !!", REVISION 1 Drown by: MK Reviewed by: KK Project No: 08-0147-00 Date 30 MAY 08 23 JUNE 08 REFLECTED CEILING PLAN Original drawing is 24" x 36 ". Scale entities accordingly if reduced A2B.1 1/4' DEVICES SHOWN STACKED IN PLAN ARE TO ALIGN VERT. AS SHOWN BELOW 1. LOCATED SWITCHPLATES, ELECTRICAL AND TELEPHONE WALL OUTLETS AT NEAREST STUD FROM SCALED LOCATION ON PLAN, UNLESS SPECIFICALLY DIMENSIONED ON PLAN, ELEVATION, OR LOCATION AS PER DIAGRAM ABOVE. 2. CENTER FIRE ALARM STROBES DIRECTLY ABOVE FIRE EXTINGUISHER CABINETS WHERE BOTH OCCUR. 0 " 4 " 8 " 1 2 " AT LOCATION AS DIMENSIONED ON PLAN; OR NEXT TO DOOR / OPENING AS DIMENSIONED BELOW FIRE ALARM STROBE FRAME WHERE OCCURS ROOM SIGNAGE, ETC. THERMOSTAT LIGHT & PROJECTION SCREEN SWITCHES, WALL MOUNTED OCCUPANCY SENSOR CARD READER WHERE OCCURS HARDWARE LATCH FINISHED FLOOR TELEPHONE OUTLET ELECTRICAL OUTLET C GENERAL DEVICE ALIGNMENT u r BOTTOM OF STRUCTURE SEALANT ATTACH GWB TO METAL STUDS LONG LEG TOP TRACK CEILING AS SCHEDULED 3 5/8' X 20 GA. METAL STUDS STUDS @ 24" OC, TO 16' -0' MAX. HEIGHT VERIFY EXISTING WIDTH IN FIELD 1 LAYER OF 5/8" TYPE 'X' GYP. BD. EA. SIDE OF METAL STUDS. INSULATION UON ON PLANS POWDER DRIVEN FASTENER 0 24'oc MET RUNNER TRACK SEALANT CONCRETE SLAB NTS NON -RATED FLOOR TO DECK PARTITION 3" = 1 ,_ 0 „ 12 GA. BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 1/2" BOTH A ENDS OF WIRE —TYP. CROSS RUNNER MAIN RUNNER DISTANCE FROM BRACING WIRES TO CROSS RUNNERS NOTE PROVIDE ACT SUSPENSION GRID TO COMPLY WITH IBC SECTION 1621 MINIMUM STANDARD PER SECTION 9.6 ASCE7. VERIFY REQUIREMENTS WITH CITY OFFICIALS. ACT SEISMIC BRACING DIAGRAM BOTTOM OF / 1 STRUCTURE 0" 4" 8" 12" 12 GA. VERTICAL HANGER WIRE AT 4' —O' EACH WAY WITH MINIMUM 3 TIGHT TURNS IN 1 1/2" BOTH ENDS OF WIRE SEISMIC COMPRESSION STRUT SUSPENDED CEIUNG AS SCHEDULED 3/8" CONT. FOAM SOUND ISOLA11ON TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF TAPTING SM. AND 3 // /4" PIPE SLEEVE D S INSULATION 2 1/2' X 25 GA METAL STUDS 0 24" OC, TO 10' -9" MAX. HEIGHT. VERIFY EXISTING WIDTH IN FIELD 1 LAYER 5/8' TYPE 'X' GYP. BD. EA. SIDE OF METAL STUDS POWDER DRIVEN FASTENER 0 24' OC MET. RUNNER TRACK SEALANT CONCRETE SLAB NTS 2"X2'X12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTBIERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5'--0' OR LESS 2 1/2'x25 GA METAL STUD BRACING 0 8' —O' OC TO STRUCTURE DIRECTION ALTERNATE PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5' -0" TO 1O' -0' SHALL USE NESTED OR BACK TO BACK 3 -1/2" 25 GA. STEEL. STUDS. ABOVE 10' -0' OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTION WEIGHT 15Ibs. /P.S.F NON -RATED FLOOR TO CEILING PARTITIO 0 " 9" RAD. FOR DESIGN INTENT ONLY Up no m VERIFY MIN. 1 -0" PARKING ONLY VAN ACCESSIBLE PERMIT REQUIRED I 11 . 1:12 : : SLOPE 3 1 -0 f, STAINLESS STEEL FASTENERS WHITE LETTERS & SYMBOL ON BLUE BACKGROUND METAL SIGN ADDITIONAL SIGN AT VAN ACCESSIBLE PARKING SPACES ONLY G.I. POST PROVIDE SLEEVE IN STRUCT. SLAB, GROUT SIGN POST TOPPING SLAB OVER STRUCT. PT SLAB NOTES: 1. PROVIDE SIGN AT EACH NEW ACCESSIBLE PARKING STALL. 36 "x36" BLUE FIELD BACKGROUND 3" WHITE PAINT BORDER 3" WIDE PAINT STRIPE TRAFFIC LINE WHITE NOTE: PROVIDE AT EACH NEW HANDICAP PARKING STALL. CURB RAMP TO HAVE DETECTABLE WARNING SURFACE W/ 1:12 SLOPE MAX. USE TRUNCATED DOMES ALIGNED IN A SQUARE GRID PATTERN, COLOR WHITE. FLARED SIDES OF CURB TO HAVE A MAX. 1:10 SLOPE. ADVANTAGE TACTILE SYSTEM OR APPROVED EQUAL DOOR & HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE 103 104 106A 1068 107A 1078 DOOR c7 W 1 3 -0" 3'--0" 3' -0" 6' -0" 8' —O' 3' -0" cs 1..w 48' 7 -0" 7' -0" 7 -0" 7' -0' 7 -0" T -0' A A A B B A 48 4 1 3 3 1 HARDWARE GROUP GROUP 1 SINGLE, PASSAGE LATCHSET NON —RATED GROUP 2 SINGLE, OFFICE LOCKSET NON —RATED GROUP 3 DOUBLE, STOREROOM LOCKSET NON —RATED GROUP 4 SINGLE, STOREROOM LOCKSET NON —RATED SIDELIGHT rn A WD WD WD WD WD WD N/A N/A N/A N/A N/A N/A w a 1/4" TEMPERED HARDWARE GROUP HARDWARE 1 PASSAGE LATCHSET 2 PAIR HINGES 1 WALL — MOUNTED DOOR STOP 1 OFFICE FUNCTION LOCKSET 2 PAIR HINGES 1 WALL — MOUNTED DOOR STOP 1 STOREROOM FUNCTION LOCKSET 4 PAIR HINGES 2 WALL— MOUNTED DOOR STOPS 1 SIDEBOLTS ON IMAGINE LEAF 1 STOREROOM FUNCTION LOCKSET 2 PAIR HINGES 11 WALL — MOUNTED DOOR STOPS DOOR TYPES WIDTH A —WOOD FRAME FINISH TO MATCH SUITE STANDARD FLUSH S.C. WOOD DOOR FINISH TO MATCH SUITE STANDARD 3 WOOD FRAME FINISH TO MATCH SUITE STANDARD FLUSH S.C. WOOD DOOR FINISH TO MATCH SUITE STANDARD SIDELIGHT /GLAZING SCHEDULE N/A w WD REMARKS NOT AN EXIT DOOR SIDELIGHT /GLAZING TYPES I— = C..D W Z 1-- _1 (J7 WIDTH 1 A "I WOOD FRAME FINISH TO MATCH SUITE STANDARD GLAZING AS SCHEDULED MATCH EXISTING CONDITIONS RECEIVED JUN 2 4 2008 PERMIT CENTER Tenant: INTERLINK SUPPLY ANDOVER EXECUTIVE BUSINESS PARK, BLDG 13 641 INDUSTRY DRIVE TUKWILA, WA 98188 A Tenant Improvement for: REIT Management & Research LLC ANDOVER EXECUTIVE PARK, BLDG 3 617 INDUSTRY DRIVE TUKWILA, WA 98188 v v' burgess design 1326 Fifth Avenue Suite 500. Seattle . WA 98101 TEL' 706.587.7120 FAX'2o5. 587.7122 M reproduction & intellectual property rights reserved c 2008 Professional seal No. Issue Description PERMIT SET Q REVISION 1 Project No: 08- 0147 -00 interiors 1® architecture KIP G. KOLODZIEJSKI STATE OF WASHINGTON 7196 Drawn by: MK Reviewed by: KK Date 30 MAY 08 23 JUNE 08 DOOR SCHEDULE SIDELIGHT SCHEDULE / DETAILS Original drawing is 24" x 36 ". Scale entities accordingly if reduced A.9.1