Loading...
HomeMy WebLinkAboutPermit D08-318 - WESTFIELD SOUTHCENTER MALL - QWEST - KIOSK2800 S t UTHCENTER MALL K -0980 DO WEST -318 Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: QWEST Address: 2800 SOUTHCENTER MALL, #K -0980 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Cit34111bf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: SEAN NELSON Address: 1801 CALIFORNIA ST, FL 44 , DENVER CO 80202 Phone: 303 - 965 -8469 Contractor: Name: DIAMOND SPECIALTIES & MFG Address: 22825 NW DOGWOOD , HILLSBORO OR 97124 Phone: 503 - 640 -4699 Contractor License No: DIAMOSM957RW DESCRIPTION OF WORK: INSTALL 10' X 10' KIOSK Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC - 10/06 $60,000.00 DEVELOPMENT PERMIT * * continued on next page ** Permit Number: D08 -318 Issue Date: 07/02/2008 Permit Expires On: 12/29/2008 Expiration Date: 01/10/2010 Fees Collected: $1,517.55 International Building Code Edition: 2006 Occupancy per IBC: D08 -318 Printed: 07 -03 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D08 - 318 Issue Date: 07/02/2008 Permit Expires On: 12/29/2008 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: � Date: 1 — 3 - 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give auth • rity to violate or cancel the provisions of any other state or local laws regulating construction oo the perforce of work. I am authoriz • sign and obtain this development permit. Date: 3/USy Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 ` - 2/9L - ?g /.9- C Oi2D D08 -318 Printed: 07 -03 -2008 City of Tukwila Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Tenant: QWEST 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: D08 - 318 Status: ISSUED Applied Date: 06/10/2008 Issue Date: 07/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D08 -318 Printed: 07 -03 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D08 -318 ordinances governing or local laws regulating Printed: 07 -03 -2008 Tenant Name: Mailing Address: c`(aii.i ctorr for Company Name: Mailing Address: Contact Person: E -Mail Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ltttp: //www. ei. tukwf la.wa. us Site Address: r��tr! SL r\-VC Pr 'C V \3 Property Owners Name: Name: $ee.e N 50C \ Day Telephone 333 /cps 2S469 Mailing Address: ?\01 C. �1,�oc� , VI 44 CInves c o 70 ? `` cit St �eq� Zip E -Mail Address: n .1 1 fir\ C )e 4, Cr _O -\ Fax Number: "C> lCp - ` 1 Company Name: TE67? Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print ** `AREiITEC Q'`R C QRD'y Company Name: Mailing Address: Q:Npptiealiondromrs- Appticatioe Oo liocn -20x6 - Permit Applimlion.doc Revised: X -20116 bt, �j' �F( lee t tca �- (pg fofumhing ant ,Cas.PIpin Contact Person: E -Mail Address: Contractor Registration Number: King Co Assessor's Tax No.: � ' 34 42 - tac ( 6 Suite Number:- Floor: New Tenant: ❑ .....Yes 11 71. City State t too : 14:.1 y .: 1 n us e !et s am Eby. A rc hl e Re rd Zip Mailing Address: State Zip City Day Telephone: Fax Number. Expiration Date: NI Oe, I0 O 1-1 `' � kA - PEA - , 5T- MOD x CD S Zip ' SL \ Day Telephone: �-7� - ata 'S' /7/ t e Da Tele hone: T S •. @ R L ( -e..S c r. , Gower Fax Number: 30 , , - C99 o9 " d S s'. - J '.,�. - .y ;HryJ., 9 i v"i�" t"'at•' :u; ^ r dry• sr !`Y'v X, �(f SJ i ?'.'# it t } t� pr;GS,+.9 i< 111 Wang plust be Wet stampea :ly,AngineeX•pf. escorn ,• °,5 2 w t �� = s_' r r m l� 'f'''l r• w : r "6 i.g.z , , , •'t, �' +y Lw- 4.5- ,03N -cAA:4 A n.+. `• . v� }f larjj rat `� - ! - -• Y'- d' :t. -k! :: City State Zip Day Telephone: Fax Number: Page 1 of 6 „, e.” rX /4h - .. t , Ks *,.•4.: ?n,� i? �., C .' j+'n°, C F �,. .•.. :.; r T ,M 4.0 y- :. 34•Existing- ° ::IntenorR _F .,". v ,v FTn Y k '.: ig' e fnoUel r 7 4 '*t • dditioit t .� � 7 ,4 , .1, .Si ikaf2 hw dt• ,s :'>• 4 • <! — i r-,jel" . ' : , •.rc } N . e , . t`�_ k "(' �':1' �" c s�X e 5`tt e.AaCg . "a ��, _ � � up� • ;(k . > . vx ss k' y' 7 r # ' !??2t � , Y . ,t t« / p. { { t W: & f loo S'y 1 n :-, � ? tiac ed-1"4%.4. •0 " , 4ToWti . Xkrfa . ' :#Attaphdd': e sakr- : Qet4l:eddGd ort:. ..e shin d - cl : , B�7IL I�1 RIVII T I1 FO.RIVIATION .20 3)43 a ' ' `' C d'a�'•' . � • VA R IV Z S ' + Wt ^-' S ^ • . : : i�•r , i t ygy' .a. :; . .;' : ;7" ..41 Will there be new rack storage? ❑ Yes Valuation of Project (contractor's bid price): $ AO, Ca) Existing Building Valuation: $ Scope of Work (please provide detailed information): 10 X'C) ■vNStr.".\ `r--� C.\tm', t , c ? t 5 � � � � � � � ;r\ \nx\C5 mot . ®.. No If yes, a separate permit and plan submittal will be required. r • . : .- .. P ro v id e : .Du -Hu bofnp ai F (Q �T �^ : ;; • hl �.._ nw+ i<S�•":..: ryL'3[�sf�� .y,`a .[y"; ° ,�.a�• }� � 2Ay ?:;.� {ir>:�"t�`�kl�#"t;�t.s� -� �: ,�ro�.a- h.,." PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑.. ..... Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes'. attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Sa ty Data Sheets. SEPTIC SYSTEM ❑.. ..... On-site Septic System —For on - site septic system, provide 2 copies ofa current septic design approved by King County Health Department. Q:wppliestionsuomua- Applications on Line13 -2006 - remit Applicatiensloc Revised: 9 -2006 hh Page2 Date Application Accepted: 'PERMIT 0 (1�TOTE ppltcabtd to all permit in this ta QI . ;r_S!r ' '?y'.- „.e•�'.' -? � :�...:>r.Z�r. >:': = '`,`�`�,.�t � >': W { ■ Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 1053.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING at: O�VNER,�R�A�UT�HOR[ZEJa� / �// Date: Print Name: pow 1 Ve,\ Spar-- Day Telephone: c l ��(f) 1 Mailing Address: 1 SD CC:9.1 \ � CSC - t City State Zip agoi(01) l}W pplicdionsWotms- Appliewions Ou rmem3.2006 - Permit Applies Road= Revised-. 9-2056 bit Date Application Expires: jb Staff loitia : I � � ” � Page 6 of 6 Project: A .�^" Type of Inspection: . Address: � A dal Date Called: Special Instructions: Date Wanted: 7 � �, / j an, Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION VL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ,r;;4 alp Date: 7 /9� LJ $60 a /REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Type of Inspection: in/ C_ , eitt ir 'e4I b1 4 1 0 i; ', /' :1 Special Instructions: A 17 Cp.J 1 4 A4 " 1 - - de -til; cd : isiudeJ e d.. v( A4.0'o. r.( and (4 (( Otte& 67 r , . 3I` (11 Project � t. �t�� Type of Inspection: in/ C_ Addres C�, _ _� in /9 /' Date ailed: W d Date ante: &)Q a m Special Instructions: A 17 Cp.J Requester: qg Phc: : ___ Dog 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Inspector: 12 Corrections required prior to approval. Date: ri $60.00 REII PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Permit Number: D08 -318 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/10/2008 Applicant: QWEST Issue Date: Receipt No.: R08 - 02372 Initials: JEM Payment Date: 07/02/2008 09:26 AM User ID: 1165 Balance: $0.00 Payee: R & R MILLWORK TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15966 860.49 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Payment Amount: $860.49 855.99 4.50 Total: $860.49 4353 07/02 0711 TOTAL 860.49 doc: Receiot -06 Printed: 07 -02 -2008 Parcel No.: 6364200010 Address: Suite No: Applicant: QWEST Receipt No.: R08 - 02042 Initials: User ID: Payee: BLH ADMIN TRANSACTION I..IST: Type Method Descriptio Payment Check 15785 ACCOUNT ITEM LIST: Description doc: Receipt -06 R & R MILLWORK 6 1 Sout nter : •ul -.. • .• • Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2800 SOUTHCENTER MALL TUKW Account Code BUILDING - NONRES 000/322.100 PLAN CHECK - NONRES 000/345.830 mmu Development RECEIPT Amount 657.06 Permit Number: Status: Applied Date: Issue Date: Payment Amount: $657.06 Payment Date: 06/10/2008 09:15 AM Balance: $860.49 Current Pmts 61.01 596.05 Total: $657.06 D08 -318 PENDING 06/10/2008 3493 06/10 9711 TOTAL 657.06 Jim Hdggerlun, Mayor Jack Pace, Director . 11 . " • - 1 i Printed: 06 -10 -2008 -3665 SEP426 -2007 06:59 From:LOIJIS 8 COMPANY —DEN 13033751814 To:3039363228 P.1'16 CHEMICALFAMILY:, Plastic Composite pRODUCT lJSF, Decorative Surface Covering INFORMATION TEL4edON E NUMBER., (410) 519.2109 EMERGENCY TFr PHO.N IMR R: Chemtrec (800) 424 -9300 0200 Novamar Company, LLC MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE SECTION I - PRODUCT INFORMATION %(.20 .1:110d4 NAME Nevamar High Pressure Decorative Laminate® CHEMICAL NAME:, Laminated Plastic CHEMICAL FORMULA: Not Applicable Due to Composite Nature of Product MANUFACTURER'S NAME ANQ,PQORESS: NEVAMAR COMPANY, LLC Odenton Facility 8339 Telegraph. Road Odenton, MD 21113 (.410) 551 -5000 TECHNICAL CONTAOT: Lihda Cramblett Technical Manager Poet-It' Fax Note Page 1 05)2003 h.1 KcviEWED FOR---1 COOL= COMP r APPS VED JUN 2 6 2008 tY Of "nrkwila / -IN ITt Jf9 ^e 1 1SIO11 INCOMPLETE LT R # �._. RECEIVED CITY OF TUKWILA JUN 19 2008 PERMIT CENTER SEP 26 -2007 06:59 From:LOUIS 8 COMPANY -DEN 13033751814 COMPONENT WEIGHT OSHA ACGIH JGA.S. RegistryN■umberl KRCE,t JT PEL TLV No hazardous components:according to 29 CFR 1910,1200. Nuisance dust may be generated during cutting or sanding operations. Nuisance dust is considered as "Particulates Not Otherwise Classified" or "Particulates Not Otherwise Regulated ". Particulates Not Otherwise Classified or Regulated: Particulates Not Otherwise Classified or Regulated APPEARANCE AND ODOR: Laminate sheet. No discernible odor, MQL.ECUI,ARILEIGHT: Not applicable due to composite nature of product. SPECIFIC . 1.2 @70F SOLUBILITY IN. WA.T_ER: Insoluble in water. Not applicable as product is solid, run Novarnar Company. U.0 To:3039363228 P.2•16 MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE SECTION I1- HAZARDOUS COMPONENTS QSHA PEL ACGIH TLV TWA 15 mg /m3 TWA 10 mg /m3 (Total Dust) (Inhalable Particulate) STEL None STEL None TWA 5 mg /m3 TWA 3 mg /m3 (Respirable Particulate) STEL None STEL None SECTION III - PHYSICAL PROPERTIES SECTION IV - FIRE AND EXPLOSION DATA: gL ASH „POINT: Product has no flash point per Pensky Martins Closed Cup method, FiREEX1 I1GUISHING MEDIA: This material is considered a "Class A” type combustible material, Use water, foam or dry chemical to extinguish. Page 2 05/2003 SEP-26 -2007 06:59 From:LOUIS 8 COMPANY -DEN 13033751814 4 3274 0 °I CORATI V@ suoit.c FLAMMABLE LIMITS;LOWER: None UPPER: None SPED1L FIR FI ALIAG PROCEDURES: No special procedures required. Minimize accumulation of dust from cutting or sanding operations through use of local ventilation systems. High airborne concentrations of combustible dusts may be explosive If contacted with an ignition source. HA7MDO1 JS Cf MBUSTION PRQDUCTS:, Thermal decomposition may release toxic and /or hazardous gases. STABILITY; Product is stable. CONDITIONS TO AVOID: Avoid exposure to open flame. HA DOUS DECO,MPQSITION. PRODUCTS: Thermal decomposition may release toxic and/or hazardous gases. HAZARDOUS POLyMEBIZTION; Will not occur. 02003 Navarra!' Company, LLC To:3039363228 P.3/16 MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE SECTION V • REACTIVITY DATA SECTION VI - HEALTH HAZARD INFORMATION EXEOSURE FROM ROUTINE USE;, Dust from cutting or sanding operations can cause irritation to the eyes, respiratory system and skin. IIFE.CTS Q OyJREX OSURE Exposure to elevated dust levels may cause irritation to the eyes and respiratory system. Prolonged skin exposure t� dust may cause drying of the skin. Potential routes of exposure are inhalation as All as skin and eye contact. Page 3 05/2003 SEP -2007 06:59 From:LOUIS & COMPANY -DEN 13033751814 MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE El 1 RCENLCY FIRST AIQ eRCCEDURES; EYE CONTACT; Wash eyes immediately with large amounts or water, occasionally lifting upper and lower lids, until no evidence of dust remains (approximately 15 - 20 minutes). SKIN..CONTACT: Wash affected area with soap and water to remove residual dust. MAC; Remove from exposure to fresh air immediately. INGESTION: Treat symptomatically and supportively if dust is ingested, OTHER, The resin used to make this plastic contains small amounts of formaldehyde. The cured plastic may emit small amounts of formaldehyde during fabrication or if heating of the product occurs, Air testing of representative fabrication operations indicates that formaldehyde releases are minimal and formaldehyde air concentrations are below regulatory standards. Formaldehyde has been identified as a skin sensitizer in low concentrations and as a probable human carcinogen (IARC -2A, pharyngeal cancer excess in formaldehyde exposed workers). SECTION VII - TOXICITY DATA ORAL: No data available, DERM L: No data available. INHALATION: No data available. No data available. CARCINOGENCITY: Product has not been tested for carcinogenicity. 01003 Novamur: Comply, LLC SECTION VIII - SPECIAL PROTECTION INFORMATION To:3039363228 P.4'16 O^�.l .N QtIY.GI.N PRA TIC Wear safety glasses or goggles in fabrication operations that may generate airborne dust. Wear gloves during exposure to dust or frequently wash hands to remove residual dust, Maintain airborne dust limits below the exposure limits. Minimize dust generation and accumulation from fabrication operations. Sweep up dust, Avoid blowing dust with compressed air. Avoid exposure of dust to open flame and ignition sources. Electrically ground and bond all equipment used for fabrication operations. 51 AND HANDLING PRA(TICF5:, No special requirements for the product. Store dust away from heat, ignition sources and oxidizing agents. Page 4 05/2003 SEP -26 -2007 07:00 From:LOUIS & COMPANY -DEN 13033751814 • fy OE C 0 RATIVE SURFA To:3039363228 P.5 MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE M • A ft u: L. I. •► :►4 ►,: EQU IPMENT; Do not use compressed air to remove dust from equipment. Sweep or wash dust from unit. . Nl'I - TIONtAND F,NGIN ERIN G CONTROL Sti Provide adequate general and local exhaust ventilation to maintain airborne concentrations below the exposure limits. Enclose fabrication operations, where possible, to minimize dust dispersion into other work areas. RESPIRATORY PROTTION: Where dust exposures may exceed the regulatory standards, respirators should be selected by and used under the direction of a trained health and safety professional following requirements found in OSHA's respirator standard (29 CFR 1910.134) and ANSI's standard for respirator protection (288.2- 1992). EYE PROTECTION. Wear ANSI - approved safety glasses or goggles in fabrication operations that may generate airborne dust. HAND AND BODY111OZEOTI9N: To prevent drying of skin, wear gloves during exposure to dust or frequently wash hands to remove residual dust. Use hand lotion to moisten hands. SECTION IX • SPILL, LEAK AND DISPOSAL PROCEDURES ENCASE MATERIAL IS SPILLED OR RrLASED: This material is a nonhazardous waste. Dispose of dust or excess material according to applicable federal, state and local regulations. DOT: Product not regulated by D.O.T. Additional Requirements for State of California: Warning: Decorative laminate products contain formaldehyde, a substance known to the State of California to cause cancer, Laminates contain small amounts of residual formaldehyde that may be released in Measurable quantities when 'stored in bulk quantities. 02003 Nnvamnr Company, I,l C SECTION X • REGULATORY INFORMATION Page 5 05/2003 SEP -26 -2007 07:00 From:LOUIS & COMPANY -DEN 13033751814 ORATIYE 5URF�G` 02003 Nevamat Company, LLC To:3039363228 P.6/16 MATERIAL SAFETY DATA SHEET NEVAMAR HIGH PRESSURE DECORATIVE LAMINATE MSDS NUMBER: NLP, Document Number: N2002 -1 Updated: 05/03' Supersedes: 07/02 JMPORTANT: The information and data contained herein are believed to be accurate and have been compiled from sources believed to be accurate. All information contained herein is offered for your consideration, Information, investigation and verification. NEVAMAR COMPANY MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, CONCERNING THE ACCURACY OR COMPLETENESS OF THE INFORMATION AND DATA !HEREIN. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED. Nevamar Company will not be responsible for claims related to any parties' use of or reliance on information and data contained herein regardless of whether it is claimed that the information are inaccurate, incomplete, or otherwise misleading, e Page 6 06/2003 SEP -26 -2007 07:00 From:LOUIS & COMPANY -DEN 13033751814 INTERNATIONAL PAPER MATERIAL SAFETY DATA SHEET CHEMICAL NAME Laminated Plastic CHEMI E AMILX; Plastic Composite MATION TELEPHONE HERS (803) 943 »7415 (Eastern Standard Time L. _ OENCY TELFP ION UMBEL Chemtrec (800) 424-9300 MOPS -MPS APUPL.PAa81 of 5 SECTION I - PRODUCT INFORMATION PRODUCT NAME: Nevamar® High Pressure Decorative Laminate — Fire Retardant NEMA Grades HG48, HZF32 PRODUCT USE: Decorative Surface Covering for Fire Retardant Applications MANC.ACTIJRER'S N AME AN D, D� D_ International Paper Decorative Products Division Hampton Facility 304: Hoover Street Hampton, South Carolina 29924 TECHA ,L CONT Cynthia B rown Environment, Health & Safety Manager Odenton Facility 8339 Telegraph Road Odenton, Maryland 21113 SECTION Ir • HAZARDOUS COMPONENTS To:3039363228 P.7'16 COMPONENT WEIoH7' OSHA ACGIH (C.A,,�t�i Numbed PERCENT TIEL TI Ethanol, 2- chloro, phosphate (3:1) <4% None None (115 -96 -8) SEP26-2007 07:01 From:LOUIS & COMPANY-DEN 13033751814 INTERNATIoNALf9 PAPER MATERIAL SAFETY DATA SI EET PRODUCT NAME: Nevamar fligh Pressure Decorative Laminate® 01EMIcAL NAME; Laminated Plastic ClIEMICAL Not Applicable Due to Composite Nature or Product CI IiiMj9A1,41;AMILL Plastic composite PRODUCT USE: Decorative Surface Covering MANUPACTURER'S NAM11,AND.ADDAESS: International Paper Decorative Products Division 7240 Parkway Drive, Suite 310 !lawyer, Maryland 21076 jaC CT. Katrina Myers EnvirOnrnent, 1 lealth & Safety Manager F ; I MAT •N I -LEHI ; Y TE . E CheiOlree (800) M813S N 1 41'5 (410) 519-2153 (Eastern, Standard Time) 1. SECTION I - PRODUCTINFORMATION I N MI312:12. SECTION II - HAZARDOUS COMPONENTS COMPONENT WEIGI IT OSI IA (a4442.ssist urn ber r PERCENT PE No hazardous components according to 29 CFR 1910.1200, Nuisance dust may be generated during cutting or sanding operations. To:3039363228 P.8 AC0111 N wow:wain' vt!. A- re 0:14 vit•L‘ L . . ;.; 2 r YEXIIIIIIMISPECICIMJIMEISIKNEMIX.r.rnrs . SEP -26 -2007 07:01 From:LOUIS 8 COMPANY -DEN 13033751814 • Nuisance dust is considered as " Particulates Not Otherwise Classified" or "Particulates Not Otherwise Regulated". Particulates Not Otherwise Classil ed or Regulated Particulates Not, Otherwise Classified or Regulated �1j'�?1 11t�1NCls AND O I,.uiliirntic sheet, No discernible odor, MOLECULAR WI:1G11'I'i Nut applicable due to composite nature of product. s17j_cjaC GRAVITY: 1.2i 70 SQLI.Jl3.ILfl Y IN Wn'I'ER: Insoluble in water. Not applicable as product is sol id. POINT' :Product has no llashpoint per Pensky Martins C :Ioscd Cup method. )'1.R11 I X'I'IN ►,,6 N ,.(y&UIIA; This mal.criul is considered u "Class A" type combustible material. Use Nvnlcr. foam or dry chemical to extinguish. 1'LA.MN1AI3,Lli ,LLNII'I' L.OWI?,R: Nine 11PPl'sR: None ' L FIR I ' ' 'ROCIEDURI:S; No spacial procedures required, M,Stas NU' -I'ngu ; If 5 soder S.LCTION•1I1 - PHYSICAL P.I.(OP.ERT1l:S SECTION I V - P.IRC AND EXPLOSION DATA; • To:3039363228 P.9'16 OSHA P11, ACGIILTLV TWA 15 m6/m3 TWA 10 mg/m3 (Total Bust) (Inhalahle Particulate) STI;I.. None STl 1. None TWA 5 mg/m3 TWA 3 mg/m3 (Respirable Particulate) S113L None STI1, None SEP -26 -2007 07:01 From:LOUIS & COMPANY -DEN 13033751814 UNUSUAL FIIU3 AND EXPLOSION IJAZj1RUS: Minimize accumulation of dust from cutting or sanding operations through use of local ventilation systems. High airborne concentrations of combustible dusts may be explosive if contacted. with an ignition source; HAZARDOUS COMJ3USTION PRODUCTS: Thermal decomposition may release toxic and /or hazardous gases. STAPILITYi Product, is stable. :CPNI TIONS TO AVOID; Avoid exposure to open flame. MSDS NLP•l'naa 3 of 5 HAZARDOUS DECOMPOSITION P.ROpucer% Thermal decomposition may release toxic and /or hazardous gases. UTAZARDOUS POLYMERIZATION; Will not occur. SECTION V - REACTIVITY DATA SECTION VI - MAIM T(I IIAZAItI) INFORMATION To:3039363226 P.10/16 EXPOSUW71.E11,0Jvl ROVT[NE USE: Dust from cutting or sanding operations can cause irritation to the eyes, respiratory system and skin. INFECTS OF OEM Maga Exposure to elevated dust levels may cause irritation to the eyes and respiratory system. Prolonged skin exposure to dust may cause drying of the skin. BAUTI?S Q I:XPQSU]U i Potential routes of exposure are inhalation ns well as skin and eye contact. EMLR©I:NCY FIRST 61Q yROCI DURE$; gY„CQNTACT: Wash eyes immediately with large amounts or water, occasionally tilling upper and lower lids, until no evidence of dust remains (approximately 15.20 minutes). SKIN CONTASL Wash affected area with soap and water to remove residual dust. "NI [NATION; Remove from exposure to fresh air immediately. fNGE " I7 N Treat symptomatically and supportively ifdust is ingested. SEP =26 -2007 07:01 From:LOUIS 8 COMPANY -DEN 13033751814 ,n QTl flR : The resin used to make this plastic contains small amounts or formaldehyde. The cured plastic may emit si»all: amounts of formaldehyde during fabrication or if heating (tithe product occurs. Air testing of representative .fabrication operations indicates that formaldehyde releases are miniip�al and formaldehyde air concentrations are below regulatory standards, Formaldehyde has been identified as a skin sensitizer in low concentrations and as a probable human carcinogen (rARC -2A, pharyngeal cancer excess in formaldehyde exposed workers). SECTION VI.I - TOXICITY DATA 010 No data available. Qt;]VMAL: No data available. 1NUALJJION: No data available. !Y,,,;, No data available. CARCINQQLNCITY;_ Product has not been tested for carcinogenicity. SECTION VIII - SPECIAL PROTECTION INFORMATION WORK AND 1JYGIENE PRACTICES; Wear 9ale.ty glasses or goggles in fitbricat.ion operations that may generate airborne dust, Wear gloves during exposure to dust or frequently wash hands to remove residual dust. Maintain airborne dust limits below the exposure limits. Minimize dust generation ancl accumulation from fabrication operations, Sweep up dust. Avoid plowing dust with compressed air. Avoid exposure of dust to open flame and ignition sources. 13lectrically ground and bond all equipment used for fabrication operations. STORAGE AND I:IAN.DLING P17AC'I'I�I S� No special requirements for the products. Store dust away from heat, ignition _Sources and oxidizing agents. P •' `E TIV ? '1 C' ICF ! .1 G ► TINAN ' ? 0I CONTAMINATED To:3039363228 P.11/16 OUlP1 ETIT Do no use compressed air to remove dust from equipment. Sweep or wash dust from unit. ViiNTILA:1iQN AND oPINEERING CONTIIQLS; Provide adequate general and local exhaust ventilation to maintain airborne concentrations below the exposure limits.. Enclose fabrication operations, where possible, to minimize dust dispersion into githeir work areas. MINIM NL.t' 4 ur 5 SEP-26 -2007 07:02 From:LOUIS & COMPANY -DEN 13033751814 R1?SPI.[X1 PROTI2 T1O Where dust exposures may exceed the regulatory standards, respirators should be selected by and used under the direction of trained health and safety professional following requirements found in OSUA's respirator standard (29 CTR 1910.134) and ANSI's standard for respirator protection (Z$8.2- 1992), gamma= CaiON. Wear ANSI- approved safety glosses or goggles in fabrication operations that may generate airborne dust. H4N1) AN D BODY PR,OT!CTIQN1 To prevent drying of skin, wear gloves during exposure to dust or frequently wash hands to remove residual dust. Use hand lotion to moisten hands. M$D Nt.1!<I'ngu 1 ur$ SECTION IX - SPILL, LEAK AND DISPOSAL. PROCEDURES To:3039363228 P.12'16 .0 1 MATERIAUIS SP1LL,ED OR IU3LI�ASf'D This material is n non - hazardous waste. Dispose of dust or excess material according to applicable .federal, state and Local regulations. SECTION X - REGULATORY INFORMATION DOT: Product not regulated by D.O.T. MSOS NUMBER: NLP Document Number: N9702. 01:0:3 Updal.ed: 1/15/97 Supersedes: 12/1/95 Provided by: Katrina Myers, Decorative Products Division IMPORTANT: The information and data contained herein are believed to be accurate and have been compiled from sources believed to be accurate. All information contained herein is olTerecl for your consideration, information, investigation and verification, INTERNATIONAL PAPEa MAKES NO WARRANTY OP ANY KIND, EXPRf:SS OR IMPLIED, CONCERNING TI IE ACCURACY OR COMPLETENESS SS Oi TIM INFORMATION AND DATA IIEREIN, THE IMPLIED WARRANTIES 01 MERCHANTABILITY AND FITNESS PQ.K, A PARTICULAR PURPOSE' ARF SPECIFICALLY EXCLUDED, International Paper will: net be responsible for claims related to any parties' use or or reliance on information and data contained herein regardless of whether it is clairned that the information are inaccurate, incomplelc, or otherwise misleading. SEP -26 -2007 07:02 From:LOUIS R. COMPANY -DEN 13033751814 Nuisance dust may be generated during cutting or sanding operations. Nuisance dust is considered as "Particulates Not Otherwise Classified" or "Particulates Not Otherwise Regulated ". Particulates Not Otherwise Classified or Regulated Particulates Not Otherwise Classified or Regulated PPLUBILrrY IN WATER: Insoluble in water. J'K Not applicable as product is solid. NOOOS - MSDS BPLFRRAOR 2 OP 5 OSHA. PEI ACGIH TI TWA 15 mg/m3 TWA 10 mg/m3 (Total Dust) (Inhalablo Particulate) STEL None STEL None -- TWA 5 mg/m3 TWA 3 mg/m3 (Respirable Particulate) STEL None STEL None SECTION DI - PHYSICAL PROPERTIES APPEAR AND ODOR: Laminate sheet. No discernible odor. MOLECULAR. WEIGHT: Not applicable due to composite nature of product. SPECIFIC ORMITIL 1.2 @70F SECTION W . FIRE AND EXPLOSION DATA To:3039363228 P.13/16 P&ASH. POINT: Product has no flashpoint per Pensky Martins Closed Cup method FXE EXTI.N4XIISHING, This product is not defined as flammable or combustible. The material is self - extinguishing once the source of ignition is removed.. It is not sensitive to static discharge. However, this product may support combustion and decompose under fire conditions. Edittl E L ' S: LOWER: None o UPPER: . None , �r L_ F flNGG PR EDURE : No special procedures required. SEP-26 -2007 07:02 From:LOLJIS & COMPANY -DEN 13033751814 •. I0 STABILITY: Product is stable. *OS • 1405. HPLFR -PAGE 3 OF 5 S SECTION V - REACTIVITY DATA To:3039363228 ��. AND EXPLO Nluiimixe accumulation of dust from cutting or sanding operations through use of local ventilation systems, as the dust may support combustion and decompose under fire conditions. HAZARDOUS COMBUSTION 'PRODUCTS: Fire conditions may cause release toxic and/or hazardous gases such as phosphorus oxides, hydrogen chloride and oxides of .carbon. CONDITIONS TO AVOID. Avoid exposure to open flame. HAZARDOUS DEC PR D( UC1'S: Fire conditions may cause release toxic and/or hazardous gases such as phosphorus oxides, hydrogen chloride and oxides of carbon. DOU,i oL RIZAflON: Will not occur. SECTION VI - HEALTH HAZARD INFORMATION EXPOSURE FROM ROUTINE USE: Dust from cutting or sanding operations can cause irritation to the eyes, respiratory system and skin. EFFECTS OF OVEREXPOSURE: Exposure to elevated dust levels may cause irritation to the eyes and respiratory system. Prolonged skin exposure to dust may cause drying of the akin. { RQU T_FS OF EXPOSURE: Potential routes of exposure are inhalation as well as skin and eye contact. R QENCY FIRST AID FROCLDURES� EYE CONTACT: Wash eyes immediately, with large amounts or water, occasionally lifting upper and lower lids, until no evidence of dust remains (approximately 15 - 20 minutes). SKI,,,N,,,, C_CA, ': Wash affected area with soap and water to remove residual dust. ISNHALATION: Remove from exposure to fresh air immediately. INGESTION: Treat symptomatically and supportively if dust is ingested P.14'16 SEP -26 -2007 07:03 From:LOUIS 8 COMPANY -DEN 13033751814 To:3039363228 P.15'16 OTER: The resin used to make this plastic contains small amounts of formaldehyde. The cured plastic may evolve small amounts of formaldehyde when fabrication or heating of the product occurs. Air testing of representative fabrication operations indicates that formaldehyde releases are 'minimal and formaldehyde air concentrations are below regulatory standards. Formaldehyde has been identified as a skin . sensitizer in low concentrations and as a probable human carcinogen (IARC4A, pharyngeal cancer excess in formaldehyde exposed workers). The organophosphorus mixture used to provide the fire retardant characteristics of this plastic is considered a class of compounds that on typically cause cholinesterase inhibition. Human experience and animal tests with this component have not shown the mixture to be a cholinesterase inhibitor. Human symptoms of such inhibition may include salivation, sweating, headache, nausea, muscle twitching, tremors, incoordination, blurred vision, tears, abdominal cramps, diarrhea, and/or chest discomfort. SECTION VII - TOXICITY DATA ORAL: No data available. = a: No data available. INHALATION: No data available. LUL No data available. CARCINOGENCITY: Product has not been tested for carcinogenicity. SECTION VDZ - SPECIAL PROTECTION INFORMATION WORK AND HYGIENE PRACTICES: Wear safety glasses or goggles in fabrication operations that may generate airborne dust. Wear gloves during exposure to dust or frequently wash hands to remove residual dust. Maintain airborne dust limits below the exposure limits. Minimize dust generation and accumulation from fabrication operations. Sweep up dust. Avoid blowing dust with compressed air. SxORAG HANDLING PRA CTICES No special requirements for the products. Pit.OTECIIVE PRACTICES DURING MAINTENANCE gQUIPlaNT : DO not use compressed air to remove dust from equipment. Sweep or wash dust from unit. N0005 . MSDS IIPLFR.PACIE 4 OF 5 L`�Ilt+!,.� • ;ter .. 0 Provide adequate general and local exhaust ventilation to maintain airborne concentrations below the exposure limits. Enclose fabrication operations, where possible, to minimize dust dispersion into other work areas. SEP =26 -2007 07:03 From:LOUIS 8 COMPANY -DEN 13033751814 RESPIRATORY PROTECTOO1 : Where dust exposures may exceed the regulatory standards, respirators should be selected by and used under the direction of a trained health and safety professional following requirements found in OSHA's respirator standard (29 .CFR 1910.134) and ANSI's standard for respirator protection (Z88.2- 1992). EYE PROTECTION: Wear ANSI - approved safety glasses or goggles in fabrication operations that may generate airborne dust. HAND AN'D BODY PROTECTION: To prevent drying of skin, wear gloves during exposure to dust or frequently wash hands to remove residual dust. Use hand lotion to moisten hands. N0005 • MSDS EPLFB.PA08 5 OF 5 SECTION IX - SPILL, LEAK AND DISPOSAL PROCEDURES To:3039363228 P.16/16 IN CASE MATERIAL IS SPILLED OR RELEASED: Dispose of dust or excess material according to applicable federal, state and local regulations. SECTION X - REGULATORY INFORMATION DOT: Product not regulated by D.O.T. PROP 65: The component ethanol, 2- chloro, phosphate (31) is listed on the California Proposition 65 chemical list. California customers must be provided with the label "Warning! This product contains a chemical known to the State of California to cause cancer." MSDS NUMBER: HPLFR Document Number: N0005 Updated 11/12/99 Supersedes: 12/01/98 Provided by: Decorative Products Division - Environment, Health and Safety IMPORTANT: The information and data contained herein are believed to be accurate and have been compiled from sources believed to be accurate. All information contained herein is offered for your consideration, information, investigation and verification. INTERNATIONAL PAPER MAKES NO WARRtAM KIN Y OF ANY D, EXPRESS OR MPLIED, CONCERNING THE ACCURACY OR COMPLETENESS OF THE INFORMATION AND DATA HEREIN. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE SPECIFICALLY EXCLUDED. International Paper will not be responsible for claims; related to any parties' use of or reliance on information and data contained herein regardless of whether it is claimed that the information are inaccurate, incomplete, or otherwise misleading. WILSOI IaTERNATIORAL '1`s+ y logtpto Tip . cuintdL'O! j tf l C81i Common Nano Supplier Synonym Also known as. Lokweld (R 3131 PVA Adhesive Trade name Material 1 xs Manufacturer Name Proprietary Ingredient Polyvinyl acetate Residual Vinyl acetate i� ;S trfln ?� l itzar fikkieflc Physical State and Appearance Adhesive for laminate. RS$ Q SltlOfl'' ,t' abeef})hal!I<1 N in • Emergency Overview Routes of Entry Potential Chronic Ilealth Effects WILSONART INTERNATIONAL, INC. P.O. BOX 6110, Temple, TX 76503 -6110 Information Phone: 254- 207 -7000 or 800 - 433 -3222 Liquid. Potential Acute health Effects F :va=s Mildly irritating to the eyes. Medical Conditions Aggravated by Overexposure: Overexposure /Sig ymptoms See Tosirnlnl teal Information (section 11) Skin Non - Irritating to the skin. L'T'd 822£9£6£0£: Wilsonart IR) 3131 PVA Adhesive VV1LSONART INTERNATIONAL iNC. P.O. BOX 8110 - 2400 Wilson Place, Temple, TX 76503 -6110 Information Phone: 800 - 433 -3222 (U.S.A.) or Wilsonart 'R► 3131 PVA Adhesive CAS # NJTSRN 950001 9003 -20 -7 108 -05 -4 i 9, i11►1;'8 % by: eight 3 -10 15 - 40 < 0.5 Inhalarion May cause irritation of upper respiratory tract. Ingauion Not an expected route of entry. No additional information. No additional information. Material Safety - Data.. Sheet w ..»........ ..:.»......,a «....1 : : e s Rticst w►. x.rrstl : .4..443. INHALATION MAY IRRITATE RESPIRATORY TRACT. CONTACT. Skin contact. Eye contact. Inhalation. Ingestion. INCOMPLETE r'. r I� iv c,ax J.u) Code MSDSU Print Date Inflammation of the eye is characterized b'.redness, watering, and itching. USA -18389 18389 Validation Date 05 /04/2000 05/15/2000 Responsible N ame Wilsonart International Inc. ltn Case of CHEMTREC: N mereencv 800 - 424 -9300 (USA) 703-527-3887 (International) ..c..ara•v' �«aawo« ., .c�'e1�'.ivr2rlshw:.v:Ra•.ea4Y� Not available Not available. TWA: 10 ppm STEL: 15 ppm ACGIH (TLV) TWA; 35 ppm STEL: 53 ppm ACGIH • Exposure limits rLV1EWFD FO LUVE COMM MILDLY IRRITATING O THE EYES•10. � N JUN2R 2fl Ys 1 :w !. tAb:r x r .. s3 a ^.Yk2 RECEIVED May cause mild gastric irritation. CITY OF TUKIMLA VI JUN 19 7008 PERMIT CENTER • .LpAr ~JJ# �W �-1 rO1Rit S22268220£ SNI1f18Id1SIO 1Ndi:Id0 :woJd 60 :TT L002- 0£ -Ntif Wilsonart oo 3131 PVA Adhesive Page: D7 1 $ectiorar • , - . .. • H 2W Eye C:nntact In case of contact with eyes, rinse immediately with plenty of water. If irritation occurs, seek medical attention. Skin Contact Wash contaminated skin with soap and water. Wash contaminated clothing before reusing. Inhalation Allow the victim to rest in a well ventilated area. Oxygen may be administered if breathing is difficult. If irritation occurs, seek medical attention. ingestion Remove dentures if any. Have conscious person drink several glasses of water or milk. NEVER give an unconscious person anything to ingest. Induce vomiting by giving syrup of ipecac. Lower the head so that the vomit will not reenter the mouth and throat. Seek medical attention. Notes to Physician No additional information. • Flammability of the Product Non - flammable. Auto-Ignition Temperature Not applicable. Flash Points Not applicable. Flammable Limits Not applicable Products of Combustion Not applicable. Fire Hazard, in Presence of Not applicable. Varlet], Substances Explosion Hazards in Presence of Various Substance Fire Fighting Mtdiu and instructions Protective Clothing (Fire) Non - flammable. Special Remarks on Fin, No additional remark. Hazards Special Remarks on No additional remark Explosion Hazard. 4LACC'Id'@Qt;3t R@ /e�9 Small Spill and Leak I arge Spill and Leak '�1trtjA'1/il L t a i macQ'" Q »x, .w.�ww..� s s¢ a ssat a .r r9 s s x Handling Storage M ra- . .► . tea• � .. 44't.... • > ti<>COn nutict xt' 1./2•d 8222926202 : Not considered to be a product presenting risks of explosion. >wW- :YR.l! .f.'-"f^}I:i9.�� ^'iK6 "ft1•S�t]5.'f.Gt2'3tlzlh Fire fighting requires the use of a self contained breathing apparatus with a full face piece and pressure - demand or other positive- pressure mode. Absorb with an inert material and place in an appropriate waste disposal container. Absorb with an inert material and put the spilled material in an appropriate waste disposal container. Avoid breathing vapors of this product. Avoid contact with skin and eyes After handling, always wash hands thoroughly with soap and water. • Keep container tightly closed and in a well - ventilated place Do not freeze. Keep out of the reach of children. tGM: M:> iie •�KS �.... » ,....- ,.. rr'.4 ^ YI:f� • S222682202 sNI1nelaLsl0 1Nti8tia : wo Jd 60:11 L002- 02 -Nef _ ..v rM . e..., . LM . S5� — .. a l�l/ y� NK(ya"f1'153"'I � . . ea ... — d F Ate% '" +� ,f(... . ..W" ... fJ. Y Weil ..f Y7'r'n. a.....t f.M .wo uw..w ' ""'►rN'r .::. ako « -+�. ,.., ss �''�lN��.sw,v w, st d �. iy se:•.». ,•.∎ w „ t " Physical State and Liquid. Appearance Odor Acetic add. Molecular Weight Not applicable. 'Paste Not available. Color White. Molecular Formula Not applicable. pH (1% Soln/Water) 5 Boiling /Condensation Point 100 ° C (212 ° F) Meidng/F`reesing Point Not available. Critical Temperature Not available. Specific Gravity 1.094 (Water = 1) Vapor Pressure Not available, Vapor Density Not available. Volatility 48% Odor Threshold • Not available. Evaporation Rate Not available. her < 20 g/L — ~"�°"'' .. : 7'4._ .. 1 0Oaro1 fl 6or aggi, ..._. ^'P. ..... .. .::, ....: _:*?'a quo"., '132, ;..r' X0' i. .t=4,..:..., :nt` ' . .^ „s . WiIsonert Engineering Controls Personal Protection Protective Clothing (Pictograms) Product Name Proprietary Ingredient Polyvinyl acetate residual vinyl acetate 3131 PVA Adhesive Page: ,AS7 Cumuli lucal authorities far acceptable exposure limits. L/£'d on O 7 t i4nRy Provide good general ventilation or othor engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value, 822E9£6£02 : Eyer Safety glasses with side shields or splash goggles. Body No special precautions are necessary if used as intended. Respiratory A respirator is not needed under normal and intended conditions of product use. In case of insufficient ventilation, wear an approved (NIOSH) respirator with organic vapor cartridges with dust/mist pre - filter. Banda No spedal precautions are necessary if used as intended. Foci No special precautions aro necessary if used as intended. Personal Protection in Case of In case of insufficient ventilation, wear an approved (NIOSH) respirator with organic vapor cartridges. a Large Spill Splash goggles. Neoprene or rubber gloves. Boots. Full suit Exposure Limits Not available Not available. TWA: 10 ppm STEL: 15 ppm ACGIH (TLV) TWA: 35 ppm STEL; 53 ppm ACGIH A•w:....'`.�..» '.'<'`. a�.: r.- �.--:........ z».:. a �Si�w: e» Y- w*+ �+;+; tev '^"�,"�` .�.'............. S222682£02 SNIll8I211SIa 114idtiO : wo ud 6:I L002- 02 -Ntlf Wllsonart viscosity Logii. lonicity (im Water) Dispersion Properties Solubility Hazardous Polymerization Chronic Effects on Itumans Other Toxic Effects on Humans Special Remarks on Toxicity to Annuals Special Remarks on Chronic Effects on Ilutuans 3131 PVA Adhesive Not available. Between 10 and 1000 Not available. Physical Chomic.,I Comments No additional information. Partially dispersed in cold water, hot water, methanol, diethyl ether, n- octanol, acetone. Soluble in water. ...k .- . ..r Stability and Reactivity The product is stable. Conditions of Instability No additional remark. Incumpatibllity with Various Slightly reactive with reducing agents, oxidizing agents, adds, alkalis, metals. Substances Hazardous Decomposition Products of combustion include: carbon oxides (CO, CO2) Products Will not occur �/ �� -- gwvr�A.i.H I � M»YwiWrv+.+• � Wf.,.r..r< > 'Q���� ..y �ri • N✓.... +.w . NasMw+...•.....,nr N ': q..rr'r. p N» u ntwMy'nwaw1.N!,.nu`>r.«....a .� +w' yam yj�P Toxicity to Animals Mildly irritating to the eyes. This product may contain small amounts of vinyl acetate, vapors of which have been shown to cause tumors In the respiratory tract of laboratory animals. There is no evidence that it has caused cancer in humans. A component of this product has been tested for potential reproductive and teratogenic effects. When administered orally to rats and mice at doses which produced toxic effects in the mother, tissue and skeletal malformations were noted. However, no effects were seen in the rabbits treated with this compound. Thls product contains a chemical that is a suspected endocrine disrupter. Endocrine /hormone disrupters are external agents that interfere with the role of natural hormones in the body. While a variety of chemicals have been found to cause endocrine disruption in laboratory animals, adverse effects in humans have not been established. (US EPA Special Report on Endocrine Disruption, February 1997.) No additional information. No additional remarks. Page: 4/7 Vinyl acetate is metabolized to acetaldehyde, which has an IARC 28 (possibly cardnogenic to humans) classification, it has also been listed in Category 2B. May contain traces of formaldehyde; formaldehyde is classified 2A by IARC (probable human carcinogen). special Remarks on Other No additional information Toxic Effects on Humans S222682202 JNIif8IaLSIa 1Nuatio:Waud OT :TT L002- 02 -Ndf Wilsonart'"j 3131 PVA Adhesive EcuInxicity BUDS and COD Not available. Biodegradable/OECD Not available. Not determined Mobility Not available. Toxicity of d Products of Not available. Biodegradation Special Remarks on tho No additional remark. Products of Biodegradation A8, ectrot pp in c ol safid eslan�r Wage Information Waste Stream Consult your local ur regional authorities. r > a•w -star "iOO >:: us �rw zw: . ......: ...,.. .... a :.czs:: fzi?ixsiiuixia:iE:ii Spilled, contaminated, or waste material should be put into a suitable container and handled according to local, State /provincial, and federal regulations. Not available. furl Ffe%rspQf l l tl>l8 on a 3 art^^ * inr ew S i i as s^Y y wwy zrrw l.> °w nG ........... DOT Classification Not a DOT controlled material (United States). Ma rlhe Pnllutant Not a marine pollutant. Special Provisions for No additional remark. Transport ADR/RID Classification Not controlled under ADR (Europe) IMO /INIDC Classification Not controlled under IMOG, TCACI✓IAT.1 Classification Not controlled under IATA. n "S;eicuon TLS. Federal Regulation. �R�egula�etry fii#orrnlyd L�S'd 8222926202: Page: 5/7 iY.;Voy6,Y Sf.+ <fc :.4.4%•:,:MIYIRi , N: =a • w ;mow HCS Classification May cause mild eye irritation. May cause irritation of upper respiratory tract. TSCA 8(b) invantory: All ingredients are listed. TSCA 8(d) Hand S data reporting: Vinyl acetate: 2/10/813 to 2/10/98 SARA 302/304/311/312 extremely hazardous substances: Vinyl acetate SARA 302/304 emergency planning and notification: No products were found. SARA 302/304/311/312 hazardous chemicals: No products were found. SARA 311/312 MSDS distribution - chemical inventory - hazard identification: No products were found. SARA 313 toxic chemical notification and release reporting: Vinyl acetate Clean water act (CWA) 307: No products were found. Clean water act (CWA) 311: Vinyl acetate Clean air act (CAA) 112 accidental release prevention: Vinyl acetate Clean air act (CAA) 112 regulated flammable substances: No products were found. Clean air act (CAA) 112 regulated toxic substances: No products were found. • e ar • e Mifl •z ......,.,.... eaaw e�..�. • • s a � r , 441.1..4 .... - ., <za,.... ,.......... a .a- .�wsraz S222682202 9•I1118IellSIO 1Nd21da -W OS :II L002- 02 -Nef References Wilsonart IR) 3131 PVA Adhesive page; 617 International Regulation% EINECS Not available. State Reinnladons ISCT.. (EEC) R36/37- Irritating to eyes and respiratory system. International Lists Australia: Vinyl acetate Germany water class: Vinyl acetate VCI WGK: Vinyl acetate .�ecb!wt 1 8` Ot Label Requlretnentx Hazardous Material information System (U.S.A.) Pennsylvania RTK: Vinyl acetate Florida: Vinyl acetate Minnesota: Vinyl acetate Massachusetts RTK: Vinyl acetate New Jersey: Vinyl acetate California Prop. 65: This product contains the following ingredients known to the State of California to cause cancer. Formaldehyde (50 -00 -0) in trace amounts, Acetaldehyde (75 -07 -0). Ae< INHALATION MAY IRRITATE RESPIRATORY TRACT. MILDLY IRRITATING TO THE EYES UPON CONTACT. Personal Protection L /9'd 82229£620£ : • 3 » .f%�.'0 W1N{ce1Nk 0 National Firc Protection Association (U.S.A.) Health Pin Rivard Reactivity Specinc Mimed -SAX, N.I. Dangerous Properties of Industrial Materials. Toronto, Van Nostrand Reinold, 6e ed. 1984. - Patty's Industrial Hygiene and Toxicology -Manufacturer's Material Safety Data Sheet GLOSSARY: ACGIH - American Conference of Governmental Industrial Hygienists ASTM - American Society for Testing and Materials ADR - Agreement on Dangerous Goods by Road (Europe) EOM - Biological Oxygen Demand In 5 days CAS - Chemical Abstract Services CEPA - Canadian Environmental Protection Act CERCLA - Comprehensive Environmental Response, Compensation and Liability Act CFR - Code of Federal Regulations DOT - Department of Transportation DSCL - Dangerous Substances Classification and Labeling (Europe) DSL - Domestic Substance List (Canada) EEC /EU - European Economic Community/European Union EINECS - European Inventory of Existing Commercial Chemical Substances HCS - Hazard Communication System HMIS - Hazardous Material Information System IARC - International Agency for Research on Cancer LD50 /LC50 - Lethal Dose /Concentration kill 50% LDLo/LCLo - Lowest Published Lethal Dose/Concentration NFPA - National Fire Prevention Association NIOSH - National institute for Occupational Safety & Health NTP • National Toxicology Program OSHA- Occupational Safety & Health Administration PEL • Permissible Exposure Limit RCRA - Resource Conservation and Recovery Act SARA - Superfund Amendments and Reorganization Act STEL - Short Term Exposure Limit (15 minutes) TOG - Transportation of Dangerous Goods (Canada) TLV -TWA - Threshold Limit Value -Time Weighted Average TSCA - Toxic Substances Control Act WHMIS - Workplace Hazardous Material Information System S222682E132 9NIlfl8l2iLSI0 1Ntiat1G :wood TI :TT Lee2-0£ -Ndr Wilsonert n 3131 PVA Adhesive pugs. 7/7 Other Special Considerations No additional remark Validated by Wibonart Ittternatinnal Inc. on OS/04/2000. Verified by Wilsonart !ntnrnationel ins, Printed 05/15/2000. CHEMTREC:: 800424 -4300 (USA) 703 - 5273887 (International) Notice to Reader To the best of our knowledge, the information contained herein is accurate However, neither the above named supplier nor any of its subsidtaries assumes any liability whatsoever for the accuracy or completeness oldie information contained herein Final determination f suitability of any material is the sole responsibility of the user. All materials may present unlatown hazards and should be used with caution Although certain hazards are described herein, we cannot guarantee that these are the only ha ards that writ vP L'L'd 8222926202 : 5222682222 JNIlfl8I2f1SI0 1Ndi!lda:w TT : tI L002-02 -Ntif 05/16/2008 09:50 3032932275 6n �.� w Material Sa,Fety°Dati)Sheet . . Particleboard Flakeboard 80 Tiverton Court, Suite 701 Markham, Ontario, Canada, L3R 0G4 Product Particleboard Name1 CAS# Formaldehyde 50 -00-0 ' Based on sensory exposure FP r- COPY Flakeboard Piasluc >ii�rfica�lon ,> - :r �lazarccas Fn�.rde"icicit t rtfcrntation Percent —� <0.1 by weight NWP DENVER /C J D poR - Ap p r t v� �.f CE; t JUN 2 g 2 0 08 Phone: (905) 475 - 68t f 1 / Of N Rev Date: 4/7472008 1 ,,�� t, Sales Location(s) Canadian Regional Center 80 Tiverton Court, Suite 701 Markham, Ontario, Canada, L3R 0G4 Tel: (800) 268 -9830 Fax: (905) 475 -3827 US Eastern Regional Center 515 River Crossing Drive, Ste 110 Fort Mill, SC 29715 Tel: (877) 273 -7680 Fax: (800) 808 -1454 US Western Regional Center 2550 NE Old Salem Road, Albany, OR 97321 Tel: (888) 650 -6302 Fax: (541)928 -4116 Synonyms: Particleboard, Flakeboard, Duraflake This MSDS is applicable for all Flakeboard particleboard including specialty products such as moisture - resistant (MR), fire -rated (FR), (no added urea - formaldehyde resin) VESTA and VESTA FR. A ency OSHA ACGIH .., p.._ �.�vr�rrT•.j'R ",'rn."%ry'� • .'('�I1�"I!�1}C�7T(°.'I�.�'gi Exposure Limits PEL -TWA 0.75 ppm PEL -STEL 2 ppm TLV- Ceiling 0.3 ppm' Comments PAGE 02/07 Appearance and Odor: Straw yellow (light brown). No distinctive odor. Fire -rated (FR), moisture - resistant (MR), (no added urea - formaldehyde resin) VESTA and VESTA FR products may have red green, blue or purple color additives, respectively. R ECEIVED Primary Health Hazards: Wood dust and formaldehyde vapor. CITY OF TUKWILA Primary Route(s) of Exposure: JUN 19 2008 ❑ Ingestion: ® Skin: Inhalation: PERMIT CENTER (Fc1 1E1 Eye: Medical Conditions Generally Aggravated by Exposure: Wood dust or formaldehyde may aggravate pre - existing respiratory conditions or allergies. INCOMPLETE Flalceboard MSDS PB729- 08.doC LT R# 1 of 6 Rev. 04!2412008 L 1 R# , VOi-S11) 05/16/2008 09:50 3032932275 NWP DENVER Signs and Symptoms of Exposure (Wood Dust Acute: Wood dust can cause eye irritation. Certain species of wood dust can elicit allergic contact dermatitis in sensitized individuals. Wood dust may cause respiratory irritation, nasal dryness, coughing, sneezing, wheezing as a result of inhalation. Chronic: Wood dust, depending on the species, may cause allergic contact dermatitis and respiratory sensitization with prolonged, repetitive contact or exposure to elevated dust levels. Prolonged exposure to wood dust has been reported by some observers to be associated with nasal cancer. Carcinogenicity Listings (Wood Dust): t&1 NTP: Known Human Carcinogen IEI IARC Monographs: Group 1 — Carcinogenic to Humans D OSHA Regulated: Not listed NTP: According to its Tenth Report on Carcinogens, NTP states, 'Wood dust is known to be a human carcinogen based on sufficient evidence of carcinogenicity from studies in humans. An association between wood dust exposure and cancer of the nose has been observed in many case reports, cohort studies, and case- control studies that specifically addressed nasal cancer. Strong and consistent associations with cancer of the nasal cavities and paranasal sinuses were observed both in studies of people whose occupations are associated with wood dust exposure and in studies that directly estimated wood dust exposure." (ARC - Group 1: Carcinogenic to humans; sufficient evidence of carcinogenicity. This classification is primarily based on studies showing an association between occupational exposure to wood dust and adenocarcinoma of the nasal cavities and paranasal sinuses. IARC did not find sufficient evidence of an association between occupational exposure to wood dust and cancers of the oropharynx, hypopharynx, lung, lymphatic and hematopoietic systems, stomach, colon or rectum. Signs and Symptoms of Exposure (Formaldehyde): Acute: Formaldehyde may cause temporary irritation of skin, eyes, or respiratory system. Formaldehyde may cause sensitization in susceptible individuals. Chronic: Numerous epidemiological studies have failed to demonstrate a relationship between forrnaldehyde exposure and nasal cancer or pulmonary diseases such as emphysema or lung cancer. Universities Associated for Research and Education in Pathology Inc. (UAREP) concluded that there was no "convincing evidence" that formaldehyde exposure causes cancer in humans. Rats exposed to 14ppm of formaldehyde for 24 months in the laboratory developed nasal cancer. Exposure of 6 ppm did not result in statistically significant levels. The NCI epidemiology study of 26,000 workers found little evidence linking forrnaldehyde exposure to cancer. Formaldehyde is classified by OSHA and NTP as a probable or potential carcinogen. IARC has classified formaldehyde as carcinogenic to humans. Carcinogenicity Listings (Formaldehyde): ® NTP: Reasonably Anticipated to be a Human Carcinogen IARC Monographs: Group 1 — Carcinogenic to Humans 131 OSHA Regulated: Formaldehyde Gas IARC - Group 1: Carcinogenic to humans. A working group of IARC has determined that there is sufficient evidence that formaldehyde causes nasopharyngeal cancer in humans, a rare cancer in developed countries. r.t. f^-Fai ,- --r-r ^-_ u77P ^,."r -^n. rp � A l f i trNl!'i"�'• W . � 'm"^;'y F Ingestion: NAP Eye Contact: Wash material outwith clean running water. Skin Contact: If skin abraded, seek proper first aid or medical treatment. Skin Absorption: NAP Inhalation: Remove to fresh air: If irritation or other symptoms persist, consult a physician. Note to Physician: None , :7.17 : , a •.'"F'""7 `x) r "ea�o+ ^K�aT += Lm,v'F c C""� r b�t1 ,v, �' n :dr „ !`''' 4 tt Flakebcard MSDS P8729- 08.doc Page 2 of 6 Rev. 04/24'2008 PAGE 03/07 05/16/2008 09:50 3032932275 Flash Point (Method Used): NAP Flammable Limits: LFL = Wood dust: 40 grams per UFL = NAP cubic meter of air Extinguishing Media: Water spray; carbon dioxide Autoignition Temperature: 425° -• 475 °F Special Firefighting Procedures: Fire fighting procedures for wood products are well known. Unusual Fire and Explosion Hazards: 'Particleboard is not an explosion hazard, Sawing, sanding, or machining particleboard could result in the by- product wood dust. Wood dust may present a strong to severe explosion hazard if a dust cloud contacts an ignition source. NFPA Rating (Scale 0 -4): Health = 0 Fire = 1 Reactivity = 0 �. j.44770:471...''' �. Z 11 TX.• r -.1 Steps to be Taken In Case Material Is Released or Spilled: Not applicable for product in purchased form. Oust generated from sawing, sanding, drilling or routing this product may be vacuumed or shoveled for recovery or disposal. Wood dust clean -up and disposal activities should be accomplished in a manner to minimize creation of airborne dust. Precautions to be Taken In Handling and Storage: Provide adequate ventilation to reduce the possible build -up of formaldehyde vapors. '' , 7 . P " `" " ,-t.... - oval Protection , poslcrli 'e ��irrir�'�easc��r�ers Engineering Controls: Due to the explosive potential of wood dust when suspended in air, precautions should be taken during sanding, sawing or machining of wood products to prevent sparks or other ignition sources in ventilation equipment. Use of totally enclosed motors is recommended. Provide local exhaust as necessary to meet OSHA requirements for formaldehyde and wood dust exposure. Personal Protective Equipment: Respiratory Protection: Wear NIOSH/MSHA approved respirator when the permissible exposure limits to formaldehyde and /or wood dust may be exceeded. Eye Protection: Recommend goggles or safety glasses as conditions indicate when sawing, sanding or machining wood products. Skin Protection: Protective equipment such as gloves and outer garments may be needed to reduce skin contact. . PtrysFcaUChemical.Xvie~y Physical Description: A panel product manufactured from particles of wood bonded together with synthetic resins or other suitable bonding system by a process in which the inter - particle bond is created by the bonding system. Soiling Point (@ 760 mm Hg): . NAP Evaporation Rate (Butyl acetate = 1): NAP Freezing Point: NAP Melting Point: NAP Molecular Formula: NAP Molecular Weight: NAP Oil -water distribution coefficient: NAP Odor threshold: NAP pH: NAP • Solubility In Water (% by weight): Insoluble Specific Gravity (H = 1): < Vapor Density (air =1; 1 atm): NAP Flakeboard MSOS Pa129-08.doc Page 3 of 6 Rev. 04,24(2008 NWP DENVER Yl r'-'17-77). , 7:2 7 .771x 4 "%- - ,7P1177 r.. r. _ u .,,� ,... PAGE 04/07 05/16/2008 09:50 3032932275 NWP DENVER Vapor Pressure (mm Hg): NAP Viscosity: NAP % Volatile byVoliumo [@70 ° F (21 ° C)]: 0 Stability: C1 Unstable ® Stable Conditions to Avoid: High relative humidity and high temperatures increase the rate of emission of formaldehyde from particleboard. Incompatibility (Materials to Avoid): Strong oxidizing agents, strong acids Hazardous Decomposition or By- Products: Thermal and/or thermal-oxidative decomposition can produce irritating and toxic fumes and gases, including carbon monoxide, aldehydes and organic acids. Hazardous Polymerization: ❑ May occur ® Will not occur Sensitivity to Mechanical Impact: NAP Sensitivity rtto - ca Static Discharge: NAP ♦h.•yl Ox Cblca l lit Tint ilicia7;' 1 PAGE 05/07 Wood Dust: Wood dust (softwood or hardwood): OSHA Hazard Rating = 3.3; moderately toxic with probable oral lethal dose to humans being 0.5 -5 g/kg (about 1 pound for a 70 kg or 150 pound person). Source: OSHA Regulated Hazardous Substances, Government Institutes, Inc., February 1990. Wood dust (generated from sawing, sanding or machining the product) may cause nasal dryness, irritation, coughing and sinusitis. The Intemational Agency for Research on Cancer (IARC) and the National Toxicology Program (NTP) classify wood dust as a human carcinogen (IARC Group 1). This classification is based primarily on increased risk in the occurrence of adenocarcinomas of the nasal cavities and paranasal sinuses associated with exposure to wood dust. The evaluation did riot find sufficient evidence to associate cancers of the oropharynx, hypopharynx, lung, lymphatic and hematopoietic systems, stomach, colon or rectum with exposure to wood dust. Formaldehyde: OSHA Hazard Rating = 3 for local and systemic acute and chronic exposures; highly toxic. Irritation studies: human skin, 150 ug /3 days, intermittent exposure produced mild results; human eye, 1 ppm/6 minutes produced mild results. Toxicity studies: human inhalation TC of 8 ppm reported, but response not specified; human inhalation TC of 17 mg/m for 30 minutes produced eye and pulmonary results; human inhalation TC of 300 ug /m3 produced nose and central nervous system results; LC (rat, inhalation) =1,000 mg /m 30 minutes; LCso (mice, inhalation) = 400 mg /m 2 hours. Exposure to gaseous formaldehyde may cause temporary irritation to the nose and throat as well as lead to respiratory disorders. However, in a thorough review of sensory/respiratory irritation studies of formaldehyde from the standpoint of occupational exposure, an expert panel has observed exposure up to concentrations of 0.3 ppm failed to produce irritation. With regard to respiratory disorders, studies have concluded the threshold for tong -term chronic pulmonary effects is between 0.4 and 3 ppm and for chronic obstructive pulmonary disease is 2 ppm. Pre - existing respiratory disorders may be aggravated by exposure. Epidemiology studies of workers exposed to formaldehyde have failed to consistently identify an association between formaldehyde exposure and cancer. In animal studies, rats and mice exposed to high levels of formaldehyde developed nasal cancer while hamsters did not These exposure levels are far above those levels normally found in the workplace. Formaldehyde is classified by IARC as carcinogenic to humans (Group 1). A working group of IARC has determined that there is sufficient evidence that formaldehyde causes nasopharyngeal cancer in humans, a rare cancer in developed countries. NTP included formaldehyde in the annual report on carcinogens. OSHA regulates formaldehyde as a potential carcinogen for exposures exceeding 0.5 ppm. Source: OSHA Regulated Hazardous Substances, Government Institutes, Inc., February 1990; Registry of Toxic Effects of Chemical Substances (RTECS), National Institute for Occupational Safety and Health (provided by Canadian Centre for Occupational Health and Safety, CCINFO May 1995). Flakeboard MSDS PB729- 08•doe Page 4 or 6 Rev. 0412412008 05/16/2008 09:50 3032932275 fit. aogag>ca -1 or�matfori No information available at this time. 'i4 • iaii� orf 6166i-ao ; Flakeboard MSDS P13729-08.doc Page 5 of 5 Rev. 04/24/2008 NWP DENVER Not regulated as a hazardous material by the U.S. Department of Transportation. • v`...".••••• . :`1•: , Waste Disposal Method: Incinerate or landfill in accordance with local, state, and federal regulations. This product is not considered hazardous waste under federal hazardous waste regulations 40 CFR 261. Please be advised, however, state and local requirements for waste disposal may be different than federal regulations. Dry land disposal is acceptable in most states if disposed of or discarded in its purchased form. It is, however, the users responsibility to determine at the time of disposal whether the product meets EPA RCRA criteria for hazardous waste. • 1••r-- nrmr^•.,. -1 T'^'..1'�L:'�.°,e•r r r'"' �r , In1vft�CPb . �--r 777—:•7777- TSCA: This product complies with TSCA inventory requirements. CERCLA: NAP DSL: NAP OSHA: Wood products are not hazardous under the criteria of the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. However, formaldehyde emissions from this product and wood dust generated by sawing, sanding or machining this product may be hazardous. STATE RIGHT -TO -KNOW: Minnesota: Minnesota Statutes, 1984, Section 144.495 and 325F.181 require that all particleboard and medium - density fiberboard used in newly constructed housing units or sold to the public as building materials in Minnesota meet the HUD Formaldehyde Emission Standard for Particleboard, 24 CFR Sections 3280.308 and 3280.406. Furniture and furnishings not normally permanently affixed to a housing unit are not considered °building materials" and are excluded. New Jersey: Under certain conditions, this product may release free formaldehyde vapor at concentrations at or above 0.1 parts per million (ppm) but Tess than 0.5 ppm. Formaldehyde is a substance which appears on New Jersey's Environmental Hazardous Substance List. Pennsylvania: Under certain conditions, this product may release free formaldehyde vapor at concentrations at or above 0.1 parts per million (ppm) but less than 0.5 ppm. Wood dust may be generated by sawing, sanding or machining this product. Formaldehyde and wood dust (certain hardwoods as beech and oak) softwood, are substances which appear on Pennsylvania's Appendix A — Hazardous Substance Lists. California: California's Safe Drinking Water and Toxic Enforcement Act of 1986 (Initiative Measure, Proposition 65): Title 22 California Code of Regulations requires that a clear and reasonable warning be given before exposure to chemicals listed by the State as causing cancer or reproductive toxicity. Formaldehyde is on California's list of chemicals known to the State to cause cancer. SARA 313 Information: None SARA 311/312 Hazard Category: NAP HUD: Particleboard certified as meeting the Department of Housing and Urban Development (HUD) Manufacturing Home Construction and Safety Standards, 24 CFR Part 3280, does not emit in excess of 0.3 ppm free formaldehyde vapor when tested in accordance with ASTM E 1333, Large Scale Test Method for Determining 'Formaldehyde Emissions From Wood Products. FDA: NAP WHMIS Classification: This product is not considered a controlled product gyp. .-.-.w rtt': ^Pn'r' T �('.�f� 4 r+ ' - ,� •...•�ri • "T °.Y71 M1^gR�r*J el lilr� :: K 7 :777 1•i ��dr 3 ;7; 1"'�� , F. . _ �� l \'1^ „ f�hf31'k '��' �!!lI,r l'� . 7.' . r PAGE 06/07 05/16/2008 09:50 3032932275 Date Prepared: 9/20/87 Date Revised: 09/08/2006 Prepared By: Flakeboard America Limited Flakeboard MSDS available on: www.flakeboard.com User's Responsibility: The information contained in this Material Safety Data Sheet is based on the experience of occupational health and safety professionals and comes from sources believed to be accurate or otherwise technically correct. It is the user's responsibility to determine if the product is suitable for its proposed application(s) and to follow necessary safety precautions. The user has the responsibility to make sure that this sheet is the most up -to -date issue. Definition of Common Terms: ACGIH = American Conference of Governmental Industrial Hygienists C = Ceiling Limit CAS# = Chemical Abstracts System Number DOT = U. S. Department of Transportation DSL = Domestic Substance List EPA = U.S. Environmental Protection Agency IARC = International Agency for Research on Cancer IATA = International Air Transport Association IMDG = International Maritime Dangerous Goods LCLo = Lowest concentration in air resulting in death LC50 = Concentration in air resulting in death to 50% of experimental animals LDLo = Lowest dose resulting in death LD50 = Administered dose resulting in death to 50% of experimental animals LEL = Lower Explosive Limit LFL = Lower Flammable Limit MSHA = Mining Safety and Health Administration NAP = Not Applicable NAV = Not Available NIOSH = National Institute for Occupational Safety and Health NPRI = Canadian National Pollution Release Inventory NTP = National Toxicology Program OSHA = Occupational Safety and Health Administration OSHA = Occupational Safety and Health Administration PEL = Permissible Exposure Limit RCRA = Resource Conservation and Recovery Act STEL = Short -Term Exposure Limit (15 minutes) TCLo = Lowest concentration in air resulting in a toxic effect TOG = Canadian Transportation of Dangerous Goods TDLo = Lowest dose resulting in a toxic effect TLV = Threshold Limit Value TSCA = Toxic Substance Control Act TWA = Time - Weighted Average (8 hours) UFL = Upper Flammable Limit WHMIS = Workplace Hazardous Materials Information System FLAKEBOARD 80 Tiverton Court, Suite 701 Markham, Ontario, Canada, L3R 0G4 Phone: (905) 475 -9686 www.flakeboard.com Flakeboard MSDS PI3729- 06,doc Page 13 of 6 Rev. 04/2/4!2008 NWP DENVER PAGE 07/07 MSDS Print Date: 09/26/2001 jiEMICAL PRODUCT IDENTIFICATION: PRODUCT ID PRODUCT CLASS TRADE NAME 3DS prepared for: SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION LARSON DISTRIBUTORS 5925 NORTH BROADWAY DENVER Attn: TELEPHONE EMERGENCY EMERGENCY 1. Potassium hydroxide CAS# 1310 -58 -3 PCT BY WT: <1 -XPOSURE LIMIT: ACGIH TLV- CEILING OSHA PEL -TWA NIOSH REL -TWA 2 Zinc oxide CAS# 1314 -13 -2 PCT BY WT: 1 -5 EXPOSURE LIMIT: ACGIH TLV -TWA OSHA PEL -TWA NIOSH REL -TWA NIOSH REL- CEILING CO 80216 MANUFACTURER IDENTIFICATION: NAME ADDRESS CONTACT TELEPHONE 2 mg /cum N/D 2 mg /cum • H3OWB ▪ WATER BASED ADHESIVE WATERBASE FLEXWELD I • Page IMPERIAL ADHESIVES, INC: 6315 WIEHE ROAD • CINCINNATI OH 45237 513 - 351 -1300 CHEMTREC 1 -800- 424 -9300 SECTION 2 - COMPOSITION, INFORMATION ON INGREDIENTS 1 of 8 ,ki.:vitWED FOR CODE COMPLIANCE APPROVED JUN 2 6 2008 Ci Of Tukwila B1IILM VISION 10 mg /cum 15 mg /cum Total dust, 5 mg /cum Respirable dust 5 mg /cum 15 mg /cum, 15 -min TWA CITY OF SUN 19 2008 PERMIT CENTER ******************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** This product contains no reportable carcinogens or suspected carcinogens. :-; ;******************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** rl SECTION 3 - HAZARDS IDENTIFICATION - 4MERGENCY OVERVIEW: Mobile to viscous alkaline liquid with a slight odor. INCOMPLETE LTR# Can cause eye - 311 MSDS Print Date: 09/26/2001 MATERIAL SAFETY DATA SHEET PRODUCT ID: H30WB TRADE NAME: WATERBASE FLEXWELD irritation. Prolonged contact may cause eye damage. May cause skin and respiratory tract irritation. May be harmful if swallowed. Product will burn only after the water it contains is driven off. POTENTIAL HEALTH EFFECTS: For short term overexposure Page 2 of 8 EYE: Alkaline material. Direct contact with the liquid or mist can cause irritation. Prolonged contact may cause eye damage. Symptoms of exposure may include stinging, burning, tearing, and redness. SKIN: Prolonged or repeated contact can cause irritation, and dry the skin. Symptoms may include redness, burning, drying and cracking of skin. INHALATION: High concentrations of vapors are unlikely unless material is heated. Inhalation of mists or vapors and fumes from heated material can cause irritation of nose, throat, and lungs. INGESTION: Can cause irritation of the mouth, throat, and gastrointestinal tract. Symptoms may include abdominal pain, nausea, vomiting. The latex portion of product will coagulate (solidify) in the digestive tract. -j "jARGET ORGAN /CHRONIC EFFECTS: For repeated overexposure This product may contain small amounts of volatile organic compounds. During storage and processing (application, drying, curing), small amounts of organic volatiles may be released. No significant amount of exposure is anticipated when good industrial hygiene practices are observed. Prolonged contact with substances containing potassium hydroxide can cause irritation and chemical burns. Inhalation of high levels of zinc oxide dust may result in tightness of chest, metallic taste, cough, dizziness, fever, chills, headache, nausea, and dry throat. This product contains,.rosin or rosin -based resin(s). Rosin and some of its derivatives have been reported to cause skin sensitization or an allergic skin reaction such as a rash in susceptible individuals after repeated or prolonged skin contact. Skin contact with this or other rosin derivatives after sensitization'may cause an allergic skin reaction. CINOGENICITY: Based on the available information, this product is not expected to be carcinogenic in humans. This product contains no components in MSDS Print Date: 09/26/2001 Page 3 of 8 J MATERIAL SAFETY DATA SHEET PRODUCT ID: H3OWB TRADE NAME: WATERBASE FLEXWELD quantities greater than or equal to 0.1 by weight that are listed as proven or suspect carcinogens by IARC, NTP, or OSHA. RIMARY ROUTE(S) OF ENTRY: Inhalation, eye contact, skin contact SECTION 4 - FIRST AID MEASURES EYE CONTACT: Flush eyes gently with plenty of water. Consult physician. SKIN CONTACT: Wash exposed skin area with soap and water. Consult physican if irritation persists. Launder contaminated clothing before reuse. INHALATION: Remove individual to fresh air. If breathing is difficult administer oxygen. Seek medical attention. INGESTION: Dilute stomach contents with water. Do not induce vomiting. Seek medical attention. )TE TO PHYSICIAN: Any treatment that might be required for overexposure should be ... directed at the control of symptoms and the clinical condition. SECTION 5 - FIRE FIGHTING MEASURES FIRE AND EXPLOSIVE PROPERTIES OF THE CHEMICAL: No unusual fire or explosion hazards. Product will not burn but may spatter if the temperature exceeds the boiling point of water. The solids portion of the product is combustible and will decompose during combustion or under pyrolysis conditions giving off toxic fumes. Closed containers may rupture if exposed to extreme heat or fire. Flammability Classification • N/A DOT: N/A Flashpoint N/A Flammable /Explosive Limits Lower -N /A o Volume in Air 'Upper -N /A % Volume in Air Auto - ignition Temperature • N/A grINGUISHING MEDIA: k•) Same as for surrounding fire. Liquid material is not flammable. Water, foam, carbon dioxide, and dry chemical are suitable for use on dry MSDS Print Date: 09/26/2001 Page 4 of 8 MATERIAL SAFETY DATA SHEET PRODUCT ID: H30WB TRADE NAME: WATERBASE FLEXWELD solids fire. FIRE - FIGHTING PROCEDURES AND EQUIPMENTS: Wear a self - contained breathing apparatus when fighting fires. Water may be used to keep fire - exposed containers cool until fire is out. SECTION 6 - ACCIDENTAL RELEASE MEASURES CONTAINMENT AND CLEAN -UP: Stop spill at source. Contain spilled liquid with sand, earth, vermiculite or other inert absorbent material. Prevent spill from contaminating soil or from entering sewage and drainage systems, and other bodies of water. Persons not wearing protective equipment should be excluded from area of spill until clean -up has been completed. If recovery is feasible transfer to clean container by suction or other suitable means. If recovery is not feasible, admix with inert absorbent material and place in appropriately marked chemical waste container for disposal. Flush spill area with water spray. Wash contaminated property before the material dries. Spilled product is very slippery. Use care to avoid falls. A film will form on drying. SECTION 7 - HANDLING AND STORAGE HANDLING: Handle with reasonable care. Avoid breathing spray mist. Avoid repeated or prolonged breathing of vapors. Avoid eye contact and repeated or prolonged skin contact. When opening containers remove top slowly to relieve any pressure build -up. Do not transfer product to unmarked container. Keep out of the reach of children. For industrial use only. Containers of this material may be hazardous when emptied. Because emptied containers retain product residues (vapor, liquid and /or solid), all hazard precautions given in the data sheet must be observed. Any proposed use of this product in elevated temperature processes or in spray applications should be thoroughly evaluated to assure that safe operating conditions are established and maintained. STORAGE: Keep product containers cool, dry, and away from sources of ignition. Use and store this product with adequaCe ventilation. Keep product containers tightly closed when not in use. Avoid freezing temperatures during storage. i Minimize contact with atmospheric air to revent innoculation anon with microorganisms which can cause decomposition and moldy overgrowth. MSDS Print Date: 09/26/2001 MATERIAL SAFETY DATA SHEET 1) PRODUCT ID: H30WB If headspace ventilation is required, skin formation on emulsion surface. Page 5 of 8 TRADE NAME: WATERBASE FLEXWELD use humidified air to reduce SPECIAL COMMENTS: Practice safe working procedures and good personal hygiene. Use protective equipment when necessary. Wash thoroughly after handling and before eating, drinking, smoking, or using toilet facilities. SECTION 8 - EXPOSURE CONTROLS, PERSONAL PROTECTION EYE PROTECTION: Chemical splash goggles are advised. Consult with safety representative. Readily accessible eyewash stations and safety showers in work areas are recommended. SKIN PROTECTION: The use of chemical resistant gloves is recommended (consult with safety equipment supplier). If necessary, wear impervious clothing and boots. RESPIRATORY PROTECTION: Not required under normal conditions of use in a well ventilated workplace. NGINEERING CONTROLS: General mechanical ventilation and /or local exhaust recommended . SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Physical State Color pH Vapor Pressure Vapor Density Boiling Range Water Solubility Specific Gravity Density VOC (less water and exempt solvent) • VOC (less water and exempt,solvent) • Evaporation Rate Volatile (o Wt) Volatile (o Vol) Static Electricity Explosion Liquid White 10.5 ( +/- 1.0) 17.00 mmHg @ 68F .62 Air = 1 Lower 212.0 F Higher -N /A Water dispersible 1 103 9.1789 LB /GL .065 LB /GL 7.78 GM /L .200 (n -Butyl Acetate 45.2764 49.8344 N/A - - - - -- MATERIAL SAFETY DATA SHEET -- - - - - -- ---------------- - - - - -- PRODUCT ID: H3OWB TRADE NAME: WATERBASE FLEXWELD _NCOMPATIBILITIES: Avoid contact with: Strong acids (mineral acids) Strong bases (alkalies, caustics) Strong oxidizing agents Water sensitive materials DECOMPOSITION: Hazardous combustion and decomposition products: Carbon monoxide and carbon dioxide Acrid (choking) smoke and fumes Hydrogen chloride Other unidentified organic compounds and toxic substances CONDITIONS TO AVOID: Coagulation may occur following freezing, thawing, boiling, or the addition of chemicals. MSDS Print Date: 09/26/2001 Page 6 of 8 SECTION 10 - STABILITY AND REACTIVITY )LYMERIZATION: Product will not undergo hazardous polymerization. 'ABILITY: Stable under normal conditions of temperature and pressure. No data for product. SECTION 11 - TOXICOLOGICAL INFORMATION SECTION 12 - ECOLOGICAL INFORMATION ECOTOXICOLOGICAL INFORMATION: AQUATIC TOXICITY: No information is available for product. DO NOT DISCHARGE TO STREAMS, LAKES, PONDS OR SEWERS. ENVIRONMENTAL FATE: No data for product. SECTION 13 - DISPOSAL CONSIDERATIONS W'\STE DISPOSAL: Do not flush to sewer. Dispose of in accordance with all applicable /federal, state or provincial, and local laws and regulations. Disposal through licensed waste disposal facilities is suggested. MSDS Print Date: 09/26/2001 PRODUCT ID: H30WB * * ** *This product is not regulated by DOT. * * * ** DOT HAZARD CLASS: DOT PACKAGING GROUP: FEDERAL REGULATIONS: TSCA (U.S. Toxic Substances Control Act) Status: The intentional ingredients of this product are listed. SARA 313 INFORMATION: This product contains the following substances subject to the reporting requirements of Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40 CFR Part 372. Zinc oxide CAS# 1314 -13 -2 PCT BY WT: 1 -5 TATE REGULATIONS: The following statement is made in order to comply with the California Safe Drinking Water and Toxic Enforcement Act of 1986: WARNING: This product contains a chemical(s) known to the state of California to cause cancer. INTERNATIONAL REGULATIONS: No data available for product. J SECTION 14 - TRANSPORT INFORMATION HMIS Information: MATERIAL SAFETY DATA SHEET SECTION 15 - REGULATORY INFORMATION SECTION 16 - OTHER INFORMATION Regulatory Manager Joseph Salib MSDS Prepared by • Dennis Sanders MSDS Print Date • 09/26/2001 MSDS Revision Number : 1 MSDS Revision Date. . . - 01/23/2001 Health- 2 Flammability- 0 Reactivity- 0 Page 7 of 8 TRADE NAME: WATERBASE FLEXWELD " OF WARRANTY AND OTHER COMMENTS: iThis document has been prepared in accordance with the requirements of the OSHA Hazard Communication Standard 29 CFR 1910.1200. The information contained herein is, to the best of our knowledge and PRODUCT ID: H30WB MSDS Print Date: 09/26/2001 Page 8 of 8 belief, accurate. However, because the conditions of handling and use are beyond our control, we make no guarantee of results, and assume no liability for damages incurred by the use of this material. It is the responsibility of the user to comply with all federal, state, and local laws and regulations. The responsibility to provide a safe workplace remains with the user. The user should consider the health hazards and safety information contained herein as a guide and should take those precautions required in an individual operation to instruct employees and to develop work practice procedures for a safe work environment. ABBREVIATIONS: ACGIH: American Conference of Governmental & Industrial Hygienists. OSHA: Occupational Safety & Health Administration NIOSH: National Institute for Occupational Safety and Health IARC: International Agency for Research on Cancer NTP: National Toxicology Program TLV: Threshold Limit Value (ACGIH) PEL: Permissible Exposure Limit (OSHA) TWA: Time Weighted Average STEL: Short Term Exposure Limit PPm: parts per million mg /cum: milligrams per cubic meter of air N/D Not Determined N /A: Not Applicable HMIS: Hazardous Materials Identification System MATERIAL SAFETY DATA SHEET TRADE NAME: WATERBASE FLEXWELD TENANT SEPARATE PERMIT REQUIRED FOR: echanical l � leectrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION QWEST COMMUNICATIONS CONTACT: SEAN NELSON 1801 CALIFORNIA SUITE 4400 DENVER, COLORADO 80202 303 965 8469 t TENANT COORDINATION WESTFIELD CORPORATION 11601 WILSHIRE BLVD, 11TH FLOOR LOS ANGELES, CA 90025 ATTN: JOSH KIMMEL CONSTRUCTION DOCUMENTS QWEST KIOSK SOUTH CENTER MALL MAY 29, 2008 2800 SOUTHCENTER MALL #K -0980 TUKWILA, WA 98188 CODES: 2006 IBC 2006 IRC 20061 M C 2006 IFC 2006 UPC 2006 NATIONAL ELECTRIC CODE 2006 WASHINGTON STATE ENERGY CODE 2006 WASHINGTON STATE INDOOR AIR QUALITY CODE CONSTRUCTION TYPE: II -B OCCUPANCY TYPE: M REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. NILE C Permit No. , o t •3(B Plar review approval is subject to errors and om!ssions. Approval of construction documents does not authorize the violation of any adopted code or Rec ipt o{ approv e; Id Co and conditi •, �� ()Wedged: City of Tukwila BUILDING [MOON SHEET INDEX: COVER SHEET G -1 SITE PLAN K -1 KIOSK PLAN K -2 ELEVATIONS A & B K -3 ELEVATIONS C & D K -4 ELEVATIONS E & F K -5 ELEVATIONS G & H K -6 ELECTRICAL PLAN KtviEWED FOR CODE COMPLIANCE PP' OVE JUN 2 6 200B �v 1' Of Tukwila BUPs 1 1447_ N. RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER 170<kIS Th1 0:1fferfit relitatirat: Men: WI t2 Mtn te dsratg twire.ad h n d qiitdist Chik.n•el 44..1 Cant 470,411:.% ea t1 uttl 111W11 « Clrf 11 1111a treilZwktzl ttaalt. ralea. 11wr last01 Tir..:ex4 Ike 1 101 00 fwaki my Lick 4cyc.L FTri/ 11g vq,:f.t; t.ero Vat * TsTg& load 11.,l 0112211 41D 404 eztrtIm 4 amroirez si Watt atIraz•rs *V clam Om Ear e1j kg: inc ye attar: ttev1 ov.ia :=1 ittYr.4 u ■tite (0 - ttcn1MK 4.71e4 L r-Ac..) 13' LIR c ' 25' 20' :PP 57 K., r ; EXHIBIT 1 1 13' SITE PLAN SCALE: NTS _ FOR CD E COMPLIALICE I APPROVE (P JUN 26 2008 City Of Tukwila BUJ;.7 :TviErt%! RECEIVED CITY OF TUKWILA JUN 1 0 2008 PERMIT CENTER LOCATION: K-0980 SOUTHCENTER MALL, TUKWILA, WA 98188 = 0R 1 �;��1twtU 4 rP COMP'~ 6 • E APPROVED ' JUN 260 City of likwila BUT2 A RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER GOO JACK MORTON is spawns AW4ti PROJECT Retail Initiative PART NAME: REVLSED pOSK 226 DATES: QUANTITY: 1 PER DRAWN BY: JM Joe Na 152602MED REVISIONS: BY JM 2/28/04 DES. Ox PM. le ow. w Phoroo 1103.7304:6 F•11 0011.2510 Qwest DATE:2/06/04 PAGE #: Al of 6 SCALE 1 -1/2' = 1' BY KW 3/03104 BY JM 3/11/04 APPROVED FOR �NsTRUCTION CET. Ts VER: 1029.137 1 . r ,:vitYVED FOR JP: COMP' T P ®QED JUN 2 6 2008 Ch, rf f1 ;kwila �! r; AcT.QN Plan 10' 10' JO =JBOX — SWITCH quad = duplex A = PHONE ® =AREAS TO AVOID ELEC. DROPS 773 =PREFERRED ELEC. DROP AREA =55 WATTS ® =55 WATTS ® =55 WATTS O =80 WATTS ® =150 WATTS ® =150 WATTS ® =150 WATTS CI =60 WATTS 0 =60 WATTS © =100 WATTS 9O =20 WATTS EACH TOTAL =955 WATTS NOTE: POWER CONSUMPTION IS FOR KIOSK LIGHTS AND FANS ONLY. DOES NOT INCLUDE CLIENT EQUIPMENT. RECEIVED CITY OF TUKWLA JUN 10 2008 PERMIT CENTER GOO JACK MORTON 10 49 W. 00. «,ENT: Qwest Retail Initiative PART NNUE: KM% DATES: QuARmY: 1 PER = 1, SCALE 1 -112' DRAWN 9Y: JAA DATE:2/06 04 JCR I 15260214ED REVLSIONS: BY JAA 2/28/04 BY JAA 3/10/04 Pnn r ^tiM,� ft'T10N - DES. oET. 0.14. PJA. AE. 16 YER 1079.03 ,IgraIS se PAGER A2 of 6 42 10 12 512 18 1/2 — 25178 25 1/8 A 6 Z 29 1/4 30 PROOLICT DISPLAY - COLD- FORMED FROM 16 GAUGE STEEL UPPER PLAN SECTION 26 118 29 3/4 28 3/4 INSIDE ELEVATION ° it AU. GLASS AND FINISH DIMS. SHOULD BE CHECKED AGAINST PROTOTYPE BEFORE ORDERING 11 HARD WIRED DUPLEX (GRAY FIXTURE AND COVER PLATE ) 72 �- — 12 3/4 --I BX CABLE ,RUN WITH XTRA LENGTH , FROM AJBOX TO A SWITCH TO A QUAD BOX $O LIGHT FIXTURES IN CABS. 48 AND 9 CAN PLUG INTO THE QUAD AND BE OPERATED BY THE SWITCH. 20 1/4' GLASS TOP CAPTURED IN METAL CHANNEL 42 2158 1 RAI:A = V V I VVM $ Cf• 1 NV) IlMni PULL= HAFELE 151.09.609 (QTY.4) DOOR PUSHBUTTON LOCK = HAFELE 234.50.601(QTY.1) DRAWER LOCK = BRIGGS NAC8060C346AKA (QTY. 2) GLASS LOCK = HAFELE 233.33.701 RIGHT HAND (QTY. 1) 233.33.711 LEFT HAND (QTY.1) (KEYED ALIKE IF POSSIBLE) 20 3/8 12 3/4 O 40 3/ r 3/16 16 1 b 29 3/4 LOWER-PLAN,SECTION 1- 1/Y =v-o- 1/4' GLASS FRONT DADXlINTO THE SIDES AND BOTTOM. THE TOP PC. 5 HINGED AND LOCKED TO THE SIDES. OUTSIDE ELEVATION 1- 1/2" =1'-0" TRAP DOOR FOR WIRE ACCESS 70 1/4 70 2 71 1/4 1 f 6 70 12 12 30 29 3/4 2E 3/4 CLEAR PLASTIC EXTRUSION TO SIT ON TOP OF 1/4" VERTICAL GLASS OUTWATER PLASTICS1a30 -CL PG.66 .7 FLORESCENT FIXTURE OUTWATER UT-ES20 20' W/ A CUSTOM BENT LIGHT SHIED (SEE DETAIL) HOLES FOR TEE -NUTS TO ATTACH – KICK LIGHT BOXES ANNODIZED ALUMINUM SPECIAL HINGE AND CAPTURED GLASS CHANNEL CUSTOM (SEE PICTURE) 7 SIDE SECTION 1- 12 - =1'-0r ALL INTERIOR SURFACES ARE TO BE WHITE M.C.P. WITH WHITE P.V.C. TAPED EDGES ON THE DMDERS,DRAWER BOXES. AND SHELVES. RECEIVED CITY OF TUKWI JUN 10 2008 PERMIT CENTE 2 4 5 LA NEVAMAR WM-8 -350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Plexi 1/4" Clear Plexi ..VitWED FOR .3p COMPI.TA- 'E APPROVED City ff Tukwila 1/8 31 12 /8 JUN 2 6 2008 4 42 3 3/4 DES. OM P.M. DET. A.E Q0© JACK MORTON I. Clue A Mike w,awe.vw Plum 1101)191)1600 Frot 1102111111.46 Qwest PROJECT: Retail Initiative PART NAME: CA8 48 DATES: OUANTI1Y: 1 PER Sr uE: = 1 -12' DRAWN BY: JAA DATE:2/05/14 Joe No: 152602MED0 Re s10 a BY JAA 2/14/04 BY JAA 3/07104 APPROVED FOR CONSTRUCTION TB VCR: 1029.03 PAGE A: El of 9 22 1/6 0 22 1/8 r 10 31 3/4 5 1/2 UPPER PLAN SECTION 1- 112" =1'-O 18 12 22 7/8 mamtimummm 26 5/16 26 314 31 12 INSIDE ELEVATION 1- l2- =r-0" 52t ALL GLASS AND FINISH DIMS. SHOULD BE CHECKED AGAINST PROTOTYPE BEFORE ORDERING 16 11 66 HARD WIRED DUPLEX (GRAY FIXTURE AND COVER PLATE ) -- 1 1U L—J 64 12 22 7/8 I=1 SECTION OF WHITE PEGBOARD TO BE ATTACHED TO THE BACK OF THIS CABINET ONLY FOR MERCHANDISING 263/4 12-3/4 ELECTRICAL NOTE USE 14 -3 METAL JACKETED BX CABLE ,RUN WITH XTRA LENGTH , FROM A.1 BOX TO A SWITCH TO A QUAD BOX ,SO UGHT FIXTURES IN CABS. 4A AND 8 CAN PLUG INTO THE QUAD AND BE OPERATED BY THE SWITCH. 6 20 ACCESS HOLES 1/4' GLASS TOP_ CAPTURED IN METAL CHANNEL ACCESS HOLES 42 10" FULL EXT. DRAWER SLIDE= BRIGGS KV -01-8400 -10 (QTY. 2 PAIR) 3/4" LAMINATED SLIDING DOOR TRACK = OUTWATER TRA610060 PULL= HAFELE 151.09.609 (QTY.4) DOOR PUSHBUTTON LOCK = HAFELE 234.50.601(QTY.1) DRAWER LOCK = BRIGGS NAC8060C346AKA (QTY. 2) GLASS LOCK = HAFELE 233.33.701 RIGHT HAND (QTY. 1) 233.33.711 LEFT HAND (QTY.1) (KEYED ALIKE IF POSSIBLE) 15/16 -1 I-A 21 5/8 203/8 -LOWER-PLAN. SECTION f 18 1/2 114' GLASS FRONT DADO INTO THE SIDES AND BOTTQM. THE TOP PC. IS HINGED AND LOCKED TO THE SIDES. OUTSIDE ELEVATION 1- 12" =r-0" TRAP DOOR FOR WIRE ACCESS 64 1/4 6412 65 1/4 O 27 CLEAR PLASTIC EXTRUSION TO SIT ON TOP OF 114' VERTICAL GLASS OUTWATER PLASTICS1830-CL PG.66 — 15/16 ANNODIZED ALUMINUM FLORESCENT FIXTURE OUTWATER LIT -ES20 20 W/ A CUSTOM BENT LIGHT SHIELD (SEE DETAIL) HOLES FOR TEE -NUTS TO ATTACH — KICK LIGHT BOXES SPECIAL HINGE AND CAPTURED GLASS CHANNEL CUSTOM (SEE PICTURE) 20 15/116 r V — 8 114' MILK PLEX REMOVABLE UGHT BOX MAKE REMOVEABLE (SEE DWG. LI OF 2 7 SIDE SECTION 1 -12 1' O ALL INTERIOR SURFACES ARE WITH WMITP.V.C. pi g4; i TAPED EDGES ON THE .�.��� ° • -. DMDERS,DRAWER BOXES, AND SHELVES. 12 1 2 3 4 5 NEVAMAR WM-8-350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Plexi 1/4" Clear Plexi RECEIVED CITY OF TUKWLA JUN 1 0 2008 PERMIT CENTER t-,... it1IVtD FOR ZS': COMP!: t' . -. EAPPROVED 1 JUN 2 6 2008 cs�- f Tukwila 3 3/4 1/4' WHITE PEGBOARD STOOD OFF OF THE BACK WITH 3/4' GLUE BLOCK GOO JACK MORTON s— Jack Marion v Mono 1100.15CLOSE0 s.. ecazsawms Qwest PROJECT: Retail Initiative PART MAME CAB 4A DATES: QUANTITY: 1 PER scu.E:1 - 12' = 1' DRAWN BY: JAA DATE: 2/05134 JOB No: 152602MED rte: OM. P.M. BY JAA 2114404 BY .IAA 3/07/04 APPROVED FOR CON T10�1 DEs. D T• AE TB VEFR 102903 r r = ■■•■• . ....r ■rr.. - Iiud> �ti PAGE It: E2 of 9 LOCK = HAFELE 235.12.221 (KEYED AUKE) r 1 3 22 118 27 T 0 18 1/8 1--- 16 3/4 --1 –6 20 42 10 5 1/2 UPPER PLAN SECTION 1- 112' =V.0" 18 1/2 ° 11 25 3/4 24 3/4 31 12 INSIDE ELEVATION 1 -1t2 1-O' 4f 48 12 ALL GLASS AND FINISH DIMS. SHOULD BE CHECKED AGAINST PROTOTYPE BEFORE ORDERING 11 1 1/4 66 HARD WIRED DUPLEX (GRAY FIXTURE AND COVER PLATE ) 23 1/8 I 6 1'4 f 19 1/8 24 3/4 64 12 ) 6 1/4 37 3/4 El 163/4 KICK FILLER J 14 O ELECTRICAL NOTE USE 14 -3 METAL JACKETED BX CABLE ,RUN WITH XTRA LENGTH , FROM A J BOX TO A SWITCH TO A QUAD BOX ,SO LIGHT FIXTURES IN CABS. 4C AND 7 CAN PLUG INTO THE QUAD AND BE OPERATED BY THE SWITCH. 25 BILL SLOT WITH GROMMET T.B.D. CATCH BIN FOR BILL SLOT ACCESS HOLE ACCESS HOLES 3/W GLASS TOP CAPTURED IN METAL CHANNEL ACCESS HOLES 42 13/16 —1 21 5/8 203/8 •4144i------ 16 3/4 37 31 1 3/16 10" FULL EXT. DRAWER SLIDE= BRIGGS KV- 01-8400 -10 (QTY. 2 PAIR) 3/4 LAMINATED SLIDING DOOR TRACK = OUPNATER TRA610060 PULL= HAFELE 151.09.609 (QTY.4) DOOR PUSHBUTTON LOCK = HAFELE 23450.601(QTY.1) DRAWER LOCK = BRIGGS NAC8060C346AKA (QTY. 2) GLASS LOCK = HAFELE 233.33.701 RIGHT HAND (QTY. 1) 233.33.711 LEFT HAND (QTY.1) (KEYED ALIKE IF POSSIBLE) --Ii-- LOWER.PLAN SECTION - 1 -1/2 1 O 114 GLASS FRONT DADA INTO THE SIDES AND BOTTOM. THE TOP PC. tS HINGED AND LOCKED TO THE SIDES. OUTSIDE ELEVATION 1- 12 - =T-0 3/4 TRAP DOOR FOR WIRE ACCESS 64 1/4 64 12 65 1/4 CLEAR PLASTIC EXTRUSION TO SIT ON TOP OF 1/4 VERTICAL GLASS OUTWATER PLASTICS1830 -CL PG.66 24 3/4 5/16 ANNODIZED ALUMINUM FLORESCENT FIXTURE OUTWATER LIT -ES20 20" W/ A CUSTOM BENT LIGHT SHIELD (SEE DETAIL) HOLES FOR TEE -NUTS TO ATTACH KICK LIGHT BOXES SPECIAL HINGE AND CAPTURED GLASS CHANNEL CUSTOM (SEE PICTURE) SIDE SECTION ALL INTERIOR SURFACES ARE TO BE WHITE M.C.P. WITH WHITE P.V.C. TAPED EDGES ON THE DMDERS,DRAWER BOXES, AND SHELVES. 12 RECEIVED CITY OF TUK ILA JUN 10 2008 PERMIT CENTER 2 NEVAMAK VVM� -JJl1 nm�-�- 3 4 5 SAGAWOOO Nevamar Wash: Apple Textured WF0002E 114" White Milk P1exi 1/4" Gear Plexi CUM': Qwest Retail Initiative PART NAME CAB 4C DATES: QUM4TRY: 1 PER SCAI- E 1.112" = 1' DRAWN DY: JAA DATE:2/05/04 Jos No 152602MED REVISIONS: BY JAA 2/14104 BY JAA 3/07/04 33/4 JUN 2 6 2008 908 ROPE uG ACK MORTON Istabias kiln WOK Mau, laWamMa wW Paw* OCOVIVISM APPROVED S DET. AE TB veR: Ic29.D PAGE r: E3 of 9 31 ALL GLASS AND FINISH DIMS. SHOULD BE CHECKED AGAINST PROTOTYPE BEFORE ORDERING • 103/4 --t UPPER PLAN SECTION 1- 1/Y =1'-0" 11 43/4 03/4 HARD WIRED DUPLEX (GRAY FIXTURE AND COVER PLATE ) 22 INSIDE ELEVATION ALL INTERIOR SURFACES ARE TO BE WHITE I+LC.P. X= STOCK SAUCE INSET HINGE 3" FROM TOP AND BOTTOM KICK FILLER ACCESS H 1/4" GLASS TOP CAPTURED IN METAL CHANNEL 42 LOWER PLAN SECTION 1- 1/2" =1'-0' CLEAR PLASTIC EXTRUSION TO SIT ON TOP OF 1/4' VERTICAL GLASS OUTWATER PLASTICS1830-CL 22 OUTSIDE ELEVATION 1- 12" =1'-0" 114" GLASS FRONT DADO THE SIDES AND BOTTOM. THE TOP PC. IS HINGED AND LOCKED TO THE SIDES. HOLES FOR TEE -NUTS TO ATTACH KICK LIGHT BOXES 10" FULL EXT. DRAWER SLIDE= BRIGGS KV -01- 8400 -10 (QTY. 1 PAIR) 3/4" LAMINATED SLIDING DOOR TRACK = OUTWATER TRA610060 PULL= HAFELE 151.09.609 (QTY.4) DOOR LOCK = BRIGGS NAC8053C346AKA(QTY.1) DRAWER LOCK = BRIGGS NAC8060C346AKA (QTY. 1) GLASS LOCK = HAFELE 233.33.701 RIGHT HAND (QTY. 1) 233.33.711 LEFT HAND (QTY.1) (KEYED ALIKE IF POSSIBLE) FLORESCENT FIXTURE OUTWATER UT -ES20 20" W/ A CUSTOM BENT LIGHT SHIELD (SEE DETAIL) SPECIAL HINGE AND CAPTURED GLASS CHANNEL CUSTOM (SEE PICTURE) 20 15/16 15 1/4' MILK NEC REMOVABLE LIGHT BOX MAKE REMOVEABL E (SEE DWG. L1 OF 2 12 SIDE SECTION 1- 1/2" =1'-0" 42 3 3/4 2 3 4 5 RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER NEVAMAR WM -8-350 CARMEL SAGAWOOO Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Plexi 1/4" Clear Plexi .. .. .'WED FOR ' )P, J1%41)1�JJI�4�p _ E • JUN 2 6 2008 �+ r .1 GOO JACK MORTON .p.1.... w WS* Jock Marlon Worldo.do Mons OCO2OOSOBOO Fos 001.210AOSS CLIENT: Qwest PROJECT Retail Initiative PMT NAME CAB 5 DATES: DlwITmr: 1 PER = 1" state 1 - 12" DRAWN BY: JS DATE2 /05/04 Joe No: 152602MED REVISrONS BY JAA 2105/04 BY JAA 2/14104 BY JAA 3/12/04 APPROVED FOR CONSJRUCTlON DES DM. P.M. DEC. A.E. TB VEft 10291 PAGE It: FI of 2 ELECTRICAL NOTE USE 14 -3 METAL JACKETED BX CABLE .RUN WITH XTRA LENGTH . FROM A J BOX TO A SWITCH TO A QUAD BOX „SO LIGHT FIXTURES W CABS. 4C AND 7 CAN PLUG INTO THE QUAD AND BE OPERATED BY THE SWITCH. 512 — II L 3 O — r 3/4 42 181/2 f 31 8 1/4 --{ Y 1/ 31 ALL GLASS AND FINISH DIMS. SHOULD BE CHECKED AGAINST PROTOTYPE BEFORE ORDERING • 103/4 --t UPPER PLAN SECTION 1- 1/Y =1'-0" 11 43/4 03/4 HARD WIRED DUPLEX (GRAY FIXTURE AND COVER PLATE ) 22 INSIDE ELEVATION ALL INTERIOR SURFACES ARE TO BE WHITE I+LC.P. X= STOCK SAUCE INSET HINGE 3" FROM TOP AND BOTTOM KICK FILLER ACCESS H 1/4" GLASS TOP CAPTURED IN METAL CHANNEL 42 LOWER PLAN SECTION 1- 1/2" =1'-0' CLEAR PLASTIC EXTRUSION TO SIT ON TOP OF 1/4' VERTICAL GLASS OUTWATER PLASTICS1830-CL 22 OUTSIDE ELEVATION 1- 12" =1'-0" 114" GLASS FRONT DADO THE SIDES AND BOTTOM. THE TOP PC. IS HINGED AND LOCKED TO THE SIDES. HOLES FOR TEE -NUTS TO ATTACH KICK LIGHT BOXES 10" FULL EXT. DRAWER SLIDE= BRIGGS KV -01- 8400 -10 (QTY. 1 PAIR) 3/4" LAMINATED SLIDING DOOR TRACK = OUTWATER TRA610060 PULL= HAFELE 151.09.609 (QTY.4) DOOR LOCK = BRIGGS NAC8053C346AKA(QTY.1) DRAWER LOCK = BRIGGS NAC8060C346AKA (QTY. 1) GLASS LOCK = HAFELE 233.33.701 RIGHT HAND (QTY. 1) 233.33.711 LEFT HAND (QTY.1) (KEYED ALIKE IF POSSIBLE) FLORESCENT FIXTURE OUTWATER UT -ES20 20" W/ A CUSTOM BENT LIGHT SHIELD (SEE DETAIL) SPECIAL HINGE AND CAPTURED GLASS CHANNEL CUSTOM (SEE PICTURE) 20 15/16 15 1/4' MILK NEC REMOVABLE LIGHT BOX MAKE REMOVEABL E (SEE DWG. L1 OF 2 12 SIDE SECTION 1- 1/2" =1'-0" 42 3 3/4 2 3 4 5 RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER NEVAMAR WM -8-350 CARMEL SAGAWOOO Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Plexi 1/4" Clear Plexi .. .. .'WED FOR ' )P, J1%41)1�JJI�4�p _ E • JUN 2 6 2008 �+ r .1 GOO JACK MORTON .p.1.... w WS* Jock Marlon Worldo.do Mons OCO2OOSOBOO Fos 001.210AOSS CLIENT: Qwest PROJECT Retail Initiative PMT NAME CAB 5 DATES: DlwITmr: 1 PER = 1" state 1 - 12" DRAWN BY: JS DATE2 /05/04 Joe No: 152602MED REVISrONS BY JAA 2105/04 BY JAA 2/14104 BY JAA 3/12/04 APPROVED FOR CONSJRUCTlON DES DM. P.M. DEC. A.E. TB VEft 10291 PAGE It: FI of 2 ELECTRICAL NOTE USE 14 -3 METAL JACKETED BX CABLE .RUN WITH XTRA LENGTH . FROM A J BOX TO A SWITCH TO A QUAD BOX „SO LIGHT FIXTURES W CABS. 4C AND 7 CAN PLUG INTO THE QUAD AND BE OPERATED BY THE SWITCH. 2 -13' FLUORESENT LIGHT FIXTURES 2 -20' FLUORESENT LIGHT FIXTURES LAMINATE LAYOUT 1- 1/2"=T-0' GRAIN 20 B 3/4 3612 CAB 7 HATCH = PROPOSED ILLUMINATED AREA 6' POWER CORD OUTWATERUTSPC CLAMP ALL POWER UNES TO WALL FLORESCENT FIXTURE OUTWATER LIT -ES13 13' OUTWATER DIRECT CONNECTORLITSDS FLORESCENT FIXTURE OUTWATER UT -ES20 20 24' CONNECTOR OUTWATERLJTSCC24 PLEX DETAIL 3 - =1 %0' 42 PLAN — WIRE ACCESS 18 1- 1/2' =V-43 20 19 3/4 19 1/4 BOTH CLIPS E 12 1/8 13 12 61 ELEVATION 1- 1 =1'-0 2 - 1/8' STAGGERED LAYERS OF PLEX WITH THE DURA TRANS SANDWICHED BETWEEN LAMINATE BACK SIDE WITH RUN GRAIN I-IORIZONAL l_3612 3712 38 r 1/2 RABBIT 1/4' DEEP GLUE BLOCK ACCESS DOOR FOR LIGHTS USE CAM-LOCK #INAC6053C642AKA USE 1 12' WIDE ALUMINUM STRIPS TO CREATE INSIDE DOOR STOP 2 --t 712 71/4 SIDE ELEVATION 1- 12• =T-0r ISOMETRIC 1 -12 =T-0" fOR JUI1 2 6 Vilia otu P 1 4t 2 3 4 5 RECEIVED CITY OF TUIMILA JUN 10 2008 PERMIT CENTER NEVAMAR WM-8 -350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4' White Milk Plexi 1/4' pear Piexi NOTE -RUN ALL LAMINATE ON FACE -LONG GRAIN' FACE TO BE MADE FROM 2 PCS. 1/8 CL PLEX DRILLED FOR MOUNTING TO CASE. TRAPING DURATRANS IN BETWEEN. GOO JACK MORTON Se spoilage h leslo ▪ 1 F • qzn Qwest PROJECT: Retail Initiative PART NAME: CAB T DATES QUANTITY: 1 PER SC+LLE: AS NOTED DRAWN BY: JAA DATE:2/05/04 Jos No: 152602MF_D REVISIONS: BY JAA 2/14104 DES. 0JA PJA BY JAA 2128104 BY KW. ON 03-08-04 BY JS ON 03-29-04 APPROVED FOR CONSTRUCTION CET. AE 1B VER 1029.03 PAGE ft: H1 of 1 FLORESCENT FIXTURE OUTWATER LIT -ES13 13• OUTWATER DIRECT CONNECTOR UT-SOS 1r CONNECTOR OUTWATERLITSCCl2 FLORESCENT FIXTURE OUTWATER LIT-ES20 20' 1 CONNECTOR OUTWATERUTSCCl2 WIRE ACCESS KEYBOARD TRAY BY HUMAN SCALES #90011 RG 6' POWER CORD OUTWATERUTSPC EQ CLAMP ALL POWER LINES TO WALL ELEVATION 1- 112 135/8 114 PLEX DETAIL PLAN SECTION I--- 15 --I 4 114 EQ -- 2012 11 EQ— BOTH CUPS THIS END 31 5/8 31 3/4 a -r ACCESS • • • R FOR LIGHTS USE CAM -LOCK #NAC8053C642AKA USE 1 12' WIDE ALUMINUM STRIPS TO . CREATE INSIDE DOOR STOP NEC 1T MONITOR BY OTHERS CUSTOM MONITOR MOUNTED KEYBOARD TRAY SUPPORT EQ 3612 12' RABBIT 114' DEEP 37 1/2 12' CONNECTOR OUTWATERLITSCCl2 38 15 3/4 1 718 712 7 5/8 SIDE ELEVATION 1- 12• =r-0- 2 - 1/8' STAGGERED LAYERS OF PLEX WITH THE DURA TRANS SANDWICHED BETWEEN LAMINATE BACK AND SIDE WITH BOTH WITH HORIZONAL GRAIN DIRECTION UE BLOCK IRE ACCESS HUMAN SCALE SWING ARM AND A.D.A. RISER ASSEMBLY WITH KEY BOARD AND CUSTOM MOUNTING BRACKET (SEE 12 OF 2) FLAT PANEL MONITOR ARM BY HUMAN SCALES # M712ZS 42 PLAN 20 12 3/4 30 1 CAB 8 HATCH = PROPOSED ILLUMINATED AREA 2 12 DIA GROMMET HOLE -- GRAUN-- Ai r•r0 PM:0110,10 000 /100111 itta ALA 13 12 1 3/16 =ACCESS 13 1/2 *JAI Ajli 212DIA GROMMET HOLE LAMINATE LAYOUT 1- 112 =1 ISOMETRIC 1- 12' =1'-0" SIDE ACCESS DOOR - VVED FOR JUN 2 6 NIN 3 4 5 ,,,,1 el f ` 1k.W%a TS1Q 1 1eE RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER SAGAWOOD Nevamar Wash_ Apple Textured WF0002E 1 /4' White Milk Plexi Liri V10 Esse Lagoon NOTE - INSIDE OF WELL (i INATE ALL LAMINATE TO RUN WITH GRAJN HORZ. ALL LAMINATE ON FACES TO RUN "LONG GRAIN' 'FACES' TO BE 2 LAYERS OF 1/8 PLEX, DRILLED FOR MOUNTING TO CAB., WITH DURATRANS MOUNTED 114 BETWEEN: GOO JACK MORTON M gdrs M WPM flolaboila coa Rano Fat 023150A 056 Qwest - PROJE[: Retail Initiative P ART NAME CAB e DATES: Q nmr: 1 PER SCALE NOTE DRAVYN BY: ,IAA DES. O.K PAGE #: 11 of 1 DATE 228/04 JOB Na 152602MED00 REVISIONS: REV. -BY KW. ON 03-08-04 REV. -BY JS ON 03 -29-04 APPROVED FOR CONSTRUCTION CET. TB YETI: 102910 as mama 2 NEVAMAR WM -8-350 CARMEL FIXED BASE FOR TURNTABLE WIRE ACCESS REAR ISO -VIEW 3' =1'-0' ROTATING DISPLAY SHELF 24' CONNECTOR OUTWATERLITSCC24 2 12 DUL WIRE ACCESS DRILLED INTO BACK RABBITS FOR PLEX FROM CNC ROUTER 5 3/8 25 PLEX FACE TOP VIEW 6"X6 METAL TURNTABLE 3'=1, -0 FROM OUR STOCK 10 3/4 A-A 12 ATTACH PLEX TO CASE WITH 1/4-20 F.H.SCREWS,THEN COVER SCREWS WITH 3/4' STRIPS OF LAM (2) 13' FLUORESESNT LIGHTS 12 FRONT VIEW 3' =1 ' 0' PLEX FACE FLORESCENT FIXTURE OUTWATER LIT -ES13 13' 6' POWER CORD OUTWATERUTSPC CLAMP ALL POWER LINES TO WALL ALL CABINET PARTS MADE FROM 3/4' ONE-SIDE WHITE M.C.P. \� (WHITE SURFACE TO INSIDE CAB.) SECTION A-A FULL SCALE 212 X 1 114 DIA'B +W STANDOFF 3/4 LONG GRAIN 2 1/2 DIA ALUM TUBE. POWDER COATED —4— LID ACCESS TO LIGHTS BELOW (RABBIT AND SHOULDER FROM CNC ROUTER) 12 T 3 ---- GRAIN -- - -I SIDE VIEW 3' =1'-0' 21 5/8 20 3/8 GRAPHIC, TRAPPED BETWEEN PLEX FLUORESCENTUGI - rT OUTWATER PART NO.UT -ESI3 TWO PER UNIT FRONT ISO -VIEW 3' =r-o' 2 3 4 5 NEVAMAR WM -8-350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4' White Milk Plexi 1/4' Clear Plexi FACE MADE FROM 2 LAYERS OF 1B' PLEX, TRAPPING GRAPHIC IN BETWEEN. SOLVENT GLUE PARTS IN THIS CORNER. SEE SECTION A - A F .. , i rvifED FOR r JUN 2 6 2008 n f T IkYYiIa IMP lg RECEED CITY OF TU JUN 10 2008 PERMIT CENTER PLEX FACE QQQ JACK MORTON M opium M 1.4l1w .1.01‘ Mange W0110/17. 10 N110 00 . Robbbrillo. N.100101 Prom 0011.250DSO Qwest PROJECT: Retail initiative PART NAME Cabinet DATES: Q UANTITY: 1 PER =ALE: 3• = 1' /DRAWN BY: K.W. I DATE D2 - 17 - 04 !.TOa Na 152602MED00 1 ROASIO KW. ON 03-08-04 Ox P APPROVED A.E. y � Ta vER: 1O. D] PAGE /r J1 of 1 t 1 — 4 1 /16 — 189/16 23 3/8 66 1/16 3/4J 66 1 /16 ELEVATION NOTE NOTE ALL METAL TO BE 1/4 ALL METAL TO BE ALUMINUM FLAT STOCK POWDER COATED THE HOLES ARE TO BE WITH SPRAYLAT COUNTERSUNK FOR A #8 BONDED SILVER CRINKLE W000 SCREW # PPC818987 PLAN 23 5/16 ISOMETRIC —4— 7 1D 3 12 QTY2 1/4r 1/4 5 314 SIDE ELEVATION LIGHTS = HERA SUMUTE FROM OUTWATER HOW. (6) 20" LITES20 (4) UTSDS END TO END CONNECTORS (2)UTSPC 6' POWER CORDS LIGHT BOX 4A AND 4C FOR { JUN 2 6 2008 C " of � , Ikwila P '_ IQN RECEIVED CITY OF TUKI ILA JUN 10 2008 PERMIT CENTER 2 3 4 5 NEVAMAR WM-8-350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Ptexi 114" Clear Piexi Q0'9 JACK MORTON REVCSIONS: OJ.L PIA. d Effrorkas is lupin 10 Oakoo Poblaftwolft, NJ WW1 Mena 6092,50 0503 Qwest PROJECT: Retail Initiative PART NAME 4A A.440 4C FOR A 10x10 DATES. - VAKTrtr: 2 PER SCALE: 3' = 1' DRAWN DT: JAA DATE: 3/23/04 JO6 Nnc 152602ME13 APPROVED FOR CONeTTt1 �T10N DES. DET. A.E. TB VER: 1029.03 1 PURICELLI # 503 PAGE #: L2 of 4 3 5 NEVAMAR WM-8 -350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Plexi 1/4" Clear Plexi GOO JACK MORTON Jack Motto. Wata.ac 10 applake". aoa +vas CuENT: Qwest PROJECT: Retail Initiative UGHT RT NAME 6 FOR A PA 10%10 DATES: WA/4MT: 1 PER DRAWN 8Y. JAA JOB Na 152602MED REVISIONS: sr.ALE: r = +' DATE 323/04 17 13/16 I- 4114 —I 12 1/16 PLAN 3" = 1'-0' 361/16 35 9/16 30 1/16 3013/16 3/4 19 1/16 16 3 1/16 ELEVATION NOTE: ALL METAL TO BE 1/4" ALUMINUM FLAT STOCK THE HOLES ARE TO BE COUNTERSUNK FOR A 98 W000 SCREW NOTE ALL METAL TO BE POWDER COATED WfTH. T . BONDED sIL CRINKLE 4 PPC818987 5 3/4 ( I 4 j 114 1/4 N 18 1/16 SIDE ELEVATION LIGHTS = HERA SLIMIJTE FROM OUTWATER HDW. (1) 20' UTES20 (2) 13' LfTE13 (2) UTSCC-6 CONNECTING CABLES (1)UTSPC 6• POWER CORDS ISOMETRIC QTY.1 LIGHT BOX 5 FOR '; e VEip JUN 2 6 2 �T IkwjIa r • 'TLTOrL 1 PURICELLI # 503 RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER • PAGE t L3 of 4 18/16 6 —53/4 L-- 4 1/4 I 121/16 0 NOTE ALL METAL TO BE 1/4' ALUMINUM FLAT STOCK THE HOLES ARE TO BE COUNTERSUNK FOR A #8 WOOD SCREW ELEVATION NOTE ALL METAL TO BE POWDER COATED WITH SPRAYLAT BONDED SILVER CRINKLE # PPCB18987 PLAN 3' =v-ir 3/4 8513/16 86 1/16 801/16 8013/16 681/16 2 3 4 B DESCRIPTION PURICELLI # 503 NEVAMAR WM-8 -350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 114" White Milk Plexi 1/4" Clear Plexi 00© JACK MORTON ispolikolo 84#444 Jock IoM nmee.r. w mw1 Tom 1011.2280300 CLIENT: Qwest PROJECT: Retail Initiative LIGHT PART NE: 48 FOR 0% AM 10 DATES UAHTm: 1 PER sc.4L3" =1• DRAWN BY: JAA DATE:3/23/04 JOB No 1526021.4E000 REVISIONS APPROVED FOR CONSTRUCTIO►'I DES. ox P.U. PAGE it L4 of 4 DET. AE. TB VEM 1029.00 ISOMETRIC 3' =r-0' QTY.1 46 11/16 25 3/8 SIDE ELEVATION 3'=V-0' — 41/16— 2 117 5 3/4 I elf Tu WId 3 1 1/2 LIGHT BOX 4 LIGHTS = HERA SUMUTE • FROM OUTWATER HDW (1) 34-7/6' LITES34 (1) 463/4' UTES46 (1) 13' UTES13 (1) UTSCC-0 CONNECTING CABLES (1)UTSDS END TO END CONNECTOR (1)UTSPC 6' POWER CORDS ci9IPP VIED JUN 2 6 2008 RECEIVED CITY OF TUKWILA JUN 1 0 2008 PERMIT CENTER 1 PURICELLI # 503 2 NEVAMAR WM-8-350 CARMEL SAGAWOOD 3 Nevamar Wash. Apple Textured WF0002E 4 114" White Milk Piexi 5 1/4" Gear Pleb — 4 1/16 18 9/16. 23 3/8 66 1/16 3/4 J 66 1/16 ELEVATION 3=1%0' PLAN 3' =1' NOTE ALL METAL TO BE U4" ALUMINUM FLAT STOCK THE HOLES ARE TO BE COUNTERSUNK FOR A 88 W000 SCREW 11 NOTE: ALL METAL TO BE POWDER COATED WITH SPRAYLAT BONDED SILVER CRINKLE 0 PPC818967 23 5/16 4 — 3 1/2 1/4 --Jj- 5 3/4 —1 SIDE ELEVATION LIGHT BOX 4A AND 4C FOR ,. - n , 1. I II JUN 2 6 2008 1 tkwila UGHTS = HERA SMITE FROM OUTWATER HOW. (6) 20" UTES20 (4) LIT-SOS END TO ENO CONNECTORS (2)LITSPC 6' POWER CORDS RECEIVED CITY OF TUKW ILA JUN 10 2008 PERMIT CENTER GOO JACK MORTON D.M. I(EVrs(oNas: 14obeltawles, 01.01 f � Qwest PCT: Retail Initiative BOXES PART NAME: M AND 4C FOR A.10X15 DATES: U.HTITY: 2 PER DRAWN BY: JAA roe M¢ 152602MED APPROVED FO: . NS DES. DET. A.E. TB VER: 1019 CO PJL PAGE ft: O2 Of 6 17 13/16 2 12 12 1/16 PLAN 3 35 13/16 36 1/16 30 1/16 30 13/16 NOTE ALL METAL TO BE 1/4' ALUMINUM FLAT STOCK. THE HOLES ARE TO BE COUNTERSUNK FOR A #8 W000 SCREW ELEVATION 3' =1'-0' 4 1/4 ( T 0-02 :416 3/4J 191/16 16 31/16 — T 3 1n _1_ NOTE ALL METAL TO BE POWDER COATED WITH SPRAYLAT BONGED SILVER CRINIQE ' / PPC818987 53/4 114 -- 18 1/16 LIGHTS = HERA SUMLITE FROM OUTWATER HOW. (1) 20' UTES20 (2) 13' LRE13 (2) UTSCGB CONNECTING CABLES (1)UT-SPC 6' POWER CORDS SIDE ELEVATION 3' =1'-0' 1 ISOMETRIC QTY.1 3'=1'-0' LIGHT BOX 5A WITHOUT ENDCAP i t `... e � 1=1J l-UR JUN 2 6 2008 J ON' rlf - r 'kv►�iia r' }• '.., • .'TSjON RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER 2 3 4 NEVAMAR WM-8-350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4" White Milk Piexi 114" pear Plead 0Q® JACK MORTON I. mop won% Qwest PROJECT: Retail Initiative LIGHT BOX SA PART NAME: ENOCAP FOR A ¶mC15 T DATES xLWTU : 1 PER DRAWN ar: JAA Joe Na 15260214 REVIS1oN5: Jock Manua w p y ` womt s. � "' . 00125ILVSS SCALE: 3" = 1' PATE: 3/24/04 OVED PAGE #' 03 of 6 4 NEVAMAR WM-8-350 CARMEL SAGAWOOD Nevarnar Wash. Apple Textured WF0002E. 1/4" White Milk Ptexi 1/4" Clear Plexi Q00 JACK MORTON PROJECT: Retail Initiative PART MAJ.E: j s-raktotrr F-0R A 1OX15 OATES: 3UAMn1Y. DES. 0)4. P.M. fa shins Y MO, Jock wee.. 10 ApOsagdo Do. Muse as . 5 10112d... 1 PER Qwest DRAWN BY: JAA DAr JCS Na 152602MED REVrsras • - • r at" L 3 1/2 --- 4 — 16 25`5116 5'1 0 3,4 72 ELEVATION PLAN Y =1'•O' 0 - 1 r ISOMETRIC QTY.1 3' =r-0r 25318 — 41/16— 1 4 114 F- - 6— --I LIGHT BOX 4B STRAIGHT r 1 NOTE: NOTE ALL METAL TO BE 114" ALL METAL TO BE ALUMINUM FLAT STOCK POWDER COATED TIE HOLES ARE TO BE WITH SPRAYLAT COUNTERSUNK FOR A 68 BONDED SILVER CR6*3 E WOOD SCREW if PPC818987 LIGHTS = HERA SUMLRE FROM OUTWATER HOW. (2) 34 -718' LITES34 (1) LITSCG6 CONNECTING CABLES (1)LfTSPC 6• POWER CORDS RECEIVED p CITY 1 / OF T KWIL A JUN 1 0 2008 SIDE ELEVATIOI,PERMIT CENTER • r, JUN 2 6 2808 nf �' f kwi a a9'' 'TSTQ(j F APPROVED �- to PAGE A � Of 6 2 1/2 — 4 .5/16 P 48 1/16 3/4 ELEVATION NOTE NOTE ALL METAL TO BE 114' ALL METAL TO BE ALUMINUM FLAT STOCK POWDER COATED THE HOLES ARE TO BE WITH SPRAYLAT COUNTERSUNK FOR A S8 BONDED SILVER CRINKLE w000 SCREW 8 PPCB18967 t t 46 9/16 24 1 /16 4 4 1/16 -- 5 3/4 9 1/7 3 1/2 SIDE ELEVATION 3' =r-0' ISOMETRIC QTY.1 UGHTS = HERA SUMUTE FROM OUTWATER HOW. t_ ( 2,20 11TES20 ! _ . ►. FOR ( 1 ) UTSCGB ` o F� I L I s '1- 1 CONNECTING CABLE 1 • • '" '�' " L (,)JTSPC trIPP VE 6' POWER CORDS LIGHT BOX 4D JUN 2 6 2008 RECEIVED CITY OF TUKWILA JUN 10 2008 PERMIT CENTER 2 3 4 5 NEVAMAR WM -8-350 CARMEL SAGAWOOD Nevamar Wash. Apple Textured WF0002E 1/4' White Milk Plexi 1/4" Clear Plexi 000 JACK MORTON 11..4.a..o..» DATES MAMMY: 1 PER Drtwww BY: JAA REVISIORfi Phon• 010.200.01 Foe 000.=0 CUENT: Qwest pRo.ccT: Retail Initiative PART NAJ.E 40 BOX JOB tax 152602MED scAlE r = 1 DATE 324/04 meow PAGE f/: O5 of 6 3 4 5 SAGAWOOD Nevamar Wash. Apple Textured WF0002E 114" White Milk Plexi 1/4" Clear Plexi 909 JACK MORTON Is opium WO* J.cla Marta Wald.* 10 hmkriP. NI OWN ti CUENT: Qwest pROJEGT: Retail Initiative LIGHT BOX WITH PART N AME: awe FOR 1A 0C15 DATES: a4r.Jrnrr: 1 PER sc +F• 3" = OR& er: JAA DATE:3124/04 JOB N¢ 152602%4E REYtS10NS- -- APPROV crux OES. SET. OM. P.M. r e vER: t029.m a •••■•• PAGE It 06of6 17 13/16 — 6 — 53/4 L — 4 1/4 ---I 12 1/16 PLAN 3" =1'-0• 36 1/16 1 r6 02 19 1/16 r 3 1 /16 — 30 1/16 30 13/16 NOTE: NOTE ALL METAL TO BE 1/4" ALL METAL TO BE ALUMINUM FLAT STOCK POWDER COATED THE HOLES ARE TO BE WITH SPRAYLAT COUNTERSUNK FOR A 88 BONDED SILVER CRINKLE W000 SCREW 8 PPC618987 ELEVATION 3 =V 0 5 3/4 1 4 j 2 1/2 1/4 18 1/16 UGHTS = HERA SIJMUTE FROM OUTWATER HDW. (1)20" LRES20 (2) 13' UTE13 (2) UTSCG6 CONNECTING CAIV FS (1)UTSPC 6" POWER CORDS SIDE ELEVATION 3' =1•-0" 31/2 ISOMETRIC QTY.1 3 =1•-0 LIGHT BOX 5 WITH ENDCAP JUN 2 6 2908 r' licTnN RECEIVED CITY OF TUKWILA JUN 10 / M PERMIT CENTER 2 NEVAMAR WM&1 -sou ufru- Mtt 4 1 June 13, 2008 Sean Nelson 1801 California Street, F144 Denver, CO 80202 RE: Letter of Incomplete Application # 1 Development Permit Application D08 -318 Qwest — 2800 Southcenter Mall, #K -0980 Dear Mr. Nelson, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on June 10, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: D08 -318 s City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director P:\Permit CenterUncomplete Letters \2008 \D08 -318 Incomplete Ltr # I.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 1 • • Determination of Completeness Memo Date: June 12, 2008 Project Name: Qwest Permit #: D08 -318 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide a plan set that is drawn to scale. Reduced drawings shall not be accepted. (IBC 106.1.1) 2. Some of the following information may have been provided on the plans. The following information shall be identified on the plans as is applies to each kiosk per 2006 IBC 402.5.1 & 402.10: a. Fire - retardant - treated wood... b. Foam, plastics complying with heat release rate (see code requirements). c. Aluminum composite materials flame spread not more than 25... smoke 450 (see code requirements). d. Identify distance or clearances with dimensions on the mall corridor floor plan to show minimum clearance of 10 feet clear exit width to 8 feet height between any projection of a tenant space bordering the mall and the nearest kiosk etc. e. Minimum horizontal separation between kiosks or groupings thereof and other structures within the mall shall be 20 feet. Show dimensions if applicable. f. All voids under platforms shall be filled with a fire resistant material. Platform construction shall be of fire resistant treated materials. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. DEPARTMENTS: 1I� 'vision CO' r Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 n *PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -318 DATE: 06 -19 -08 PROJECT NAME: (WEST SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0908 Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued Fire Prevention n Planning Division Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n DUE DATE: 06-24-08 Not Applicable n No further Review Required DATE: DUE DATE: 07-22-08 Not Approved (attach comments) n DATE: Permit Coordinator n n n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 - 318 DATE: 06 - - PROJECT NAME: QWEST SITE ADDRESS: 2800 SOUTHCENTER MALL, K -0980 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART ENTS: I (Le-Ot) Bui • g Division P blic Works Complete n Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY « PLAN REVIEW /ROUTING SLIP MoO (o -I Fire Preve tion Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: Permit Center Use Only INCOMPLETE LETTER MAILED: 'f — 015 LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: n Permit Coordinator DUE DATE: 06-1 2-08 Not Applicable n No further Review Required DATE: DUE DATE: 07-10-08 Approved ❑ Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: !'-'/ 0 Planning Division n ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contact Person: City of Tukwila Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (0`(� ( D� Plan Check/Permit Number: 7 i ' 3l$' Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: )p 4-- j(1 Project Address: nn ZS 50 u. r+.,,,,,, A1 (1 *K I V e 4 7 4,6t cst l e.zv -A. Phone Number: 2426 - rD,Z - 40 7 Summary of Revision: ( " kto l'Gl w u i ''` r e.4.)1 se-,k a rte.( pv n m itt G d 6U one.., 5; ovL 4.k I° 2 4. 6.c. — This SIee( -s 1 rtel ud cd, -coy- Lam.; c* Al i 4hes , -Ire, rede.61 per r.44(. le i r.6( Prat n. h e#2.1 re ad h oz. s 4? d. e... - ca-1 114.45 6 e4%.t. rc.a1 sJ 4a reA - e- rte..e- lexe4.4 U.,: r ' .Le4.ra.o,.e___e.s VV%&, k4-1_ *a w ; l 1 b con, a i rte. f : t(1: d>6 >6 te— te,r," trr- Sheet Number(s): Q..wa v G -( K -1 ,1<-2- K -3 K.-41- k -4 "Cloud" or highlight all areas of revision including date of rev Received at the City of Tukwila Permit Center by: Entered in Permits Plus on etQ t i \applications\fomu- applications on lmekevision submittal Created: 8-13 -2004 • • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: /fwww.ci.tukwila.wa.us (�v Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVED op Tt trv,nrrl a JUN 1 9 2008 �ENMI7 CEMTEH License Information License DIAMOSM957RW Licensee Name DIAMOND SPECIALTIES & MFG INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602540694 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 22825 NW DOGWOOD Address 2 City HILLSBORO County OUT OF STATE State OR Zip 97124 Phone 5036404699 Status ACTIVE Specialty 1 OTHER (SPECIFY) Specialty 2 UNUSED Effective Date 12/16/2005 Expiration Date 1/10/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HATHAWAY, JOYCE A PRESIDENT 12/16/2005 BRANDT, PAM SECRETARY 01/06/2006 HATHAWAY, BRIAN VICE PRESIDENT 12/16/2005 Look Up a Contractor, Electrician or Plumber License Detail Washington State Depaitment of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond Company Bond Account Effective Expiration Cancel Impaired Bond 0 Received Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DIAMOSM957RW 07/03/2008