Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-365 - WA STATE LIQUOR STORE - TENANT IMPROVEMENT
WA STATE LIQUOR CONTROL BOARD 14227 TUKWILA INTERNATIONAL BL D08 -365 Contractor: Name: RIVER CITY CONSTRUCTION INC Address: PO BOX 6315 , FEDERAL WAY, WA 98063 Phone: 253 - 939 -4545 Contractor License No: RIVERCC 117OB doc: IBC -10/06 City. If Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1523049011 Permit Number: D08 -365 Address: 14227 TUKWILA INTERNATIONAL BL TUKW Issue Date: 07/29/2008 Suite No: Permit Expires On: 01/25/2009 Tenant: Name: WASHINGTON STATE LIQUOR STORE Address: 14227 TUKWILA INTERNATIONAL BL , TUKVVILA WA Owner: Name: SEG 56TH LLC Address: 845 106TH AVE SE #100 , BELLEVUE WA 98004 Phone: Contact Person: Name: RICK LENTZ Address: 1800 136 AVE NE #100 , BELLEVUE WA 98005 Phone: 425 - 747 -3177 DEVELOPMENT PERMIT DESCRIPTION OF WORK: TENANT IMPROVEMENT OF EXISTING RETAIL SPACE. 130 SQ FT OFFICE, AND REMAINING DISPLAY AREA Value of Construction: $62,000.00 Fees Collected: $1,547.25 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: II-B Occupancy per IBC: 0019 * *continued on next page ** Expiration Date: 07/03/2009 D08 -365 Printed: 07 -29 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 6411Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Print Name: doc: IBC - 10/06 I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc of work. I am authorized to sign and obtain this development permit. Signature: dN"..., l�l J " a°—t 3 Date: a2 29 s. L W igK o k-Ls Permit Number: D08 - 365 Issue Date: 07/29/2008 Permit Expires On: 01/25/2009 Date: PI/,-1 1i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -365 Printed: 07 -29 -2008 Parcel No.: 1523049011 Address: 14227 TUKWILA INTERNATIONAL BL TUKW Suite No: Tenant: WASHINGTON STATE LIQUOR STORE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -365 ISSUED 07/09/2008 07/29/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 D08 -365 Printed: 07 -29 -2008 14: ** *FIRE DEPARTMENT CONDITIONS * ** City of Tukwila 16: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 22: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 26: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the doc: Cond -10/06 D08 -365 Printed: 07 -29 -2008 aisles shall be unobstructed. (IFC 1013.4) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Combustible material shall not be stored in exits or exit enclosures. (IFC 315.2.2) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4) 32: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 33: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: Walls of corridors serving an occupant load of 30 or more shall be of not less than one -hour fire resistive construction and the ceilings shall not be less than that required for a one -hour fire resistive floor or roof system. (IBC 708.1(4)) (IBC 1016.1 Table 1016.1)) 37: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 38: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 39: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D08 -365 Printed: 07 -29 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. c Signature: (- �� Date: 6 Print Name: \ \ G \ r\ L W ` s k t. doc: Cond -10/06 D08 -365 ordinances governing or local laws regulating Printed: 07 -29 -2008 CITY OF TUKWIL Community Developmerinlepartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tulcwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Name: �1CK LtTIC2 1 frrEV - 2. Al-f ' Mailing Address: I SG I%4 11v� " E loo E -Mail Address: 'R 1 C. kL ° MIA y tj' • COM Company Name: Riv £ &1 C01J5T2,O CT Ot-J AL, Mailing Address: 1425 224 5(. NW St) L1 E > F City Contact Person: t)01Z PDESC.l -EL E -Mail Address: 4OV t rlv ea't`9 COlnS+ Contractor Registration Number: K I V E (C 1 lin t Company Name: tAtetEtC. 11417__ 0-4141M-7" Contact Person: .1 CK LE)*CZ E -Mail Address: R I • C k L e vn Icy v-ch , Cn vn N/A (Alonl ,'TU M. - re ii r I m p ')vE_ I (� Building Perm o. U 3 (or Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: 1S2 504701( Site Address: 141-2-7 T0aoIl.,94 1P d\bcrna AL &-V(7 Suite Number: Floor: ONE Tenant Name: W 1l4Yofs SCAM LI SPoe_ apfoL- &9A1.O New Tenant: ❑ Yes ❑ .. No Property Owners Name: s — 4 , �L Mailing Address: h4'S 106411 ANIE # 1O7 Sataue City State 9,6004- Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 425.7 +1. 31'11 gatEVDE tJA{1. 13005 City State Zip Fax Number: 426 •741.11 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) WA 1. 9 u ooh State Zip Day Telephone: gap • 2749 • ? - Fax Number: 1 ' 86o10. 431 'f375/ Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Mailing Address: 1600 (36 }4F ' kcD EELLEVOE W ArA. 981x5 City State Zip Day Telephone: 426. Fax Number: 425.747.7141 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: Wppltcations\Forms- Applications On trne'3 -2006 - Permit Apphcanon.doc Revised: 9 -2006 bh State Zip Page 1 of 6 BUILDING PERMIT INFORM•ON - 206 -431 -3670 al Valuation of Project (contractor's bid price): $ 2 OOO Existing Building Valuation: $ 33q 000 Scope of Work (please provide detailed information): ` ENP \f IM -OVOYI EDIT 4 EC N - 11; - ( itraFf RE1mL , biop,4 iNCWbe6 C- IYsrizt)C.7tof4 or-A I1O 0ff10E INST1 }Tlon/ e r mow m o w )Sfexllev Ay ous- riedK. 1II J j \/IN`t'L Gova-ft-let AND 5TAnl p W 648/nier5. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N1 - fink 6 Compact: aS`(Ir14 Handicap: EAV5(It• Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes IF( No If `yes', attach list of materials and storage locations on a separate 8 x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ Applcations\Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh A .. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 Floor Z6jS3 L 0 1 �Q 2e) 5 2 Floor 3" Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORM•ON - 206 -431 -3670 al Valuation of Project (contractor's bid price): $ 2 OOO Existing Building Valuation: $ 33q 000 Scope of Work (please provide detailed information): ` ENP \f IM -OVOYI EDIT 4 EC N - 11; - ( itraFf RE1mL , biop,4 iNCWbe6 C- IYsrizt)C.7tof4 or-A I1O 0ff10E INST1 }Tlon/ e r mow m o w )Sfexllev Ay ous- riedK. 1II J j \/IN`t'L Gova-ft-let AND 5TAnl p W 648/nier5. Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: N1 - fink 6 Compact: aS`(Ir14 Handicap: EAV5(It• Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes IF( No If `yes', attach list of materials and storage locations on a separate 8 x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ Applcations\Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh A .. No If yes, a separate permit and plan submittal will be required. Page 2 of 6 PERMIT APPLICATION NOTE Applicable to all permits in this apprication Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. t c b. ts2 Mailing Address: I &o 13/4904 (taut i ioo Date Application Accepted: Date Application Expires: Staff Initials: tit4 I Q:\Applications\Foms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: tit11!i(' q i W015 Day Telephone: 425 .747.31 17 6aLEYL 141154-1. ‘00495 City State Zip Page 6 of 6 Receipt No.: R08 -02770 Initials: JEM User ID: 1165 BUILDING - NONRES STATE BUILDING SURCHARGE Payee: RIVER CITY CONSTRUCTION, INC. ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1523049011 Permit Number: D08 -365 Address: 14227 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 07/09/2008 Applicant: WASHINGTON STATE LIQUOR STORE Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 30256 939.50 Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Total: $939.50 Payment Amount: $939.50 Payment Date: 07/29/2008 11:50 AM Balance: $0.00 935.00 4.50 5406 07/29 9710 TOTAL 939.50 doc: Receiot -06 Printed: 07 -29 -2008 Receipt No.: R08 -02472 Payee: MERRICK LENTZ ARCHITECT ACCOUNT ITEM LIST: Description doc: Receiot -06 PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 14681 607.75 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 1523049011 Permit Number: D08 -365 Address: 14227 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 07/09/2008 Applicant: WASHINGTON STATE LIQUOR STORE Issue Date: Initials: WER Payment Date: 07/09/2008 09:33 AM User ID: 1655 Balance: $939.50 Account Code Current Pmts 000/345.830 607.75 Total: $607.75 Payment Amount: $607.75 4608 07/09 9711 TOTAL 607.75 Printed: 07 -09 -2008 Project:,, owl( Type of Inspection: rovAt, Address: Date Called: Special Instructions: Date Wanted: /0 D � ^� vU J m. Requester: t J / Phone No: l� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \$. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Yomi r Co -iPt4 Inspector: SI 60,446t. ,Date: 1 , 0 / 0 2 0 1 U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: , / a k Pe--1., f c/ s f � Type ofI fI ? # "i' ^u � 5 I d� /Y ,/e.. 7v.,3 ,5,X€ 0 ,4 -4' ' ea c.4,4./ /.2 1 ) c 3 -�� (/a/ .... i. !J /i1F l r � CC �� `4- . / ®f.� ,�...,. ,S�l S / f / , e0� Phone No: 25-?-26-2/ S. 1 d-% 73 ,,,,, re) i....,-, _e . , , jr. 5 .,., J J cow ",,t i i�� -+.,, 6)4 CY • i Project: Type ofI fI Address: 2 7 7 _ Date Called: Special Instructions: • 21 e n " Date Wanted: am. i Phone No: 25-?-26-2/ • 5 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 U Approved per applicable codes. Inspector: 4. 4 Corrections required prior to approval. Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: . „ � Ce . (. ( a �� t Addr 2. lc m ,' 1 -- (E 1 Date Wanted: _ (Z . Qk �.m,' p.m. (-) Phone No Ir ,1 p te-(-# fln , i ,i(Ad s4 r,_, /o 4. A .,.. Projlr s r L, e v d.�_ Type of Inspection: . „ � Ce . (. ( a �� t Addr 2. Date Called: Special Instructions: /2 „,//le Date Wanted: _ (Z . Qk �.m,' p.m. Requester: Phone No INSPECTION NO. INSPECTION RECORD Retain a copy with permit ho8-31,5 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. Inspe or: Dater ( 2 __ r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: : t: Project: 1 t��� �1 i �or.! G \A Type of Inspection: e_ CUS NNAEN OF'; IN, Address: _ 1 Li 22 7 ► _I-.Y Date Called: Special Instructions: Date Wanted: R - 1 3 -. a.m. p.m. Reques`Ter: Phone No: INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: N 1 , 1. P'x,3 s 6 tae: Zx.5 41(110%)e tM , S S i 9/ 4' Dab_ l�V� I -- - e r7 $61 00 REINSPECTION EE REO IRED. Prior to inspection, fee must be poi., at 6300 Southcente Blvd., uite 100. Call to schedule reinspection. Receip i No.: Date: Project: OA S OFE. /•'C�J3 Type of Inspectio . Al 5,� • S e� < <� c • t • Address: ( 1122'l ToK AL- Date Calldd: Special Instructions: / Date Wanted: /.T a.m. Requester: Phone No 2 3 . -2 46. — 6 211 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. InspeC to D' - 3k$ •brrections required prior to approval. ri $60.00 REINSPECTION FEE REDUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. CO ENTS: di-i n A o f ;vv. gr �1 -- 1Date: Receipt No.: 'Date: tom• ..5d COMMENTS: Type of Inspection: %< /Ms t GI.}rn/n/6. " Dat ailed: Co,.Jbta tar 5 (AT T kc 1 3-t- -- d !• 9f .) v A( (C Af L- - 1 5 .1).' p G `) 11 -21 � J J I( � M p (L(_ /� i N -A"f r Requester: Phone No: 23 - )e- ( /.:m .. i; f e-A^ C. 0J-P r (,.1,114 Li i - eg eiS t -" T < - ,',F r ' e Qe t 1/,),\"\ S Ifkf - LT)J -r .re A - ( l- el L•5. . . 1 Project: //4- OA/ S i' Type of Inspection: %< /Ms t GI.}rn/n/6. �" Ad ress: / . 7 7 6 Dat ailed: Special Instructions: J / Date Wanted: c5 - V 4 G r p . Requester: Phone No: 23 - INSPECTION NO. INSPECTION RECORD Retain a copy with permit &6-f65 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Iz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Ei Corrections required prior to approval. Inspect: • Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ti Projec�t:�� /l /�(t • Z / 1,69.- T pe of Inspect : / nr `` �/U Address: s ! t �„ L Date Called ��' Date Wanted: A '...e . ,� /� ... 144-40( L0c a.m. Special Instructions: /€ � A/9,0U 1 Requester: Phone No: INSPECTION NO. INSPECTION RECORD /'� Retain a copy with permit {.., OR I py p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Iga 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS �.. ad-'• .4.•,,. ► .� �i�/ A 4,./.e .5 Atal.—• A4-trfr( Project: Via, crwits L i w, vim 4 • L. A4. 'S S Tv a.0,0 E Type of Inspection . 6 -- . •JAt-- 4 Address: i' 2. 71 C5 Suite #: i 't • Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Pre -Fire: Permits: $,'Occupancy Type: r ias..+ hbea!: w> i... aa'•sY= if;.:l�;wra.:1:�.ie;lc•. - :• n_ �rxP+. r�.::.: �l�ft. M.?... ;zwxrs':i:a:.t_..-. e . A. INSPECTION NUMBER ' ►� CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 =575 =4407 .ICI Approved per applicable codes. Word/Inspe� ction Record Form.Doc • 4 INSPECTION RECORD Retain a copy with permit 1/13/06 PERMIT UMBERS Corrections required prior to approval. COMMENTS: E V0 L Ott- t -- % -- o ( . 3i%cS(t - i qs) 6fet 1.44z e rg . j y o (C. 'tam_ _ P k. = b IL_ tr pa° - t 9 9 2.— Date:. 112'3 / Hrs.: Inspector: -. w n i�. $8 .00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 11.3; . • 4 Project: Wa. . srrryx. L 4 4..04 - j-j . Type of Inspection: 1f Fire Alarm: l - Address's, , PI Z 2.7 Suite #: - r' X' 03 Contact Person: '� Occupancy Type: Special Instructions: Phone No.: ..?5 -- war — Vi i Needs Shift Inspection: - Sprinklers: Fire Alarm: 'Hood & Du Monitor: We-Fire: Permits: Occupancy Type: L ..�_K ro.3? - t. - :- .ds..:- Y+F.ary ivy.'s: a ,,,.-r. — a'fll.t.�w•p.. — '--- .Sr-.- , _::.��w - .•� «,..:5q.+[Saz�4'.Y�a z�'asAw•"_- Ham. :.vf. %?RSi+}.•`+ina..: +�ai4??i..pjy.:f ="c�ry 4 I INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Approved per applicable codes. I INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT _e - PERMIT NUMBERS n Corrections required prior to approval. COMMENTS: CoCniA .w }} t.✓� f � ,i-r- ' .�F... EC /r d� .t , kes old,ceux4 . ft, J 4L13 Ske.StUt 1./,Avil 09244 Co leliete le 51 13hspector: J) 51c m •. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from - the City of Tukwila Finance Department. Call to schedule a reinspection. Date: AN O , Hrs.: Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: L s Mr L-, 9 v triA Type of Inspection: S,v i r+ k l,en Hood & Duct: Address: / Y 227 Suite #: 774 Contact Person : i r o n . Special Instructions: Phone No.: 7 2S3 -- cZ Needs Shift Inspection: Sprinklers: ' _ Are Alarm: Hood & Duct: Monitor: - Pre- Fire: . Permits: Occupancy Type: - INSPECTION' NUMBER El Approved per applicable codes. Word/Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit - ERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT — 444 Andover Park East, Tukwila, Wa. 98188 206- 575 - 4407--, HS rrections required prior to approval. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from . e City of Tukwila Finance Department. Call to schedule a reinspection: 1/13/06 • T.F.D. Form F.P. 113 COMMENTS: 4944- - a"i - 44erie - M' 0644.. Inspector: • S , 3 Date: 292,,3/4.)? Hrs.: / rs.. Project: WA . . L, tilt) d A--- Type of Inspection: .. S: Pe. i NIL 1.,> Z_ Address: - f qZ j' Suite #: Ill 13 Contact Person: 70,-1 Vi e.ov) Special Instructions: - - Phone No.: 2 l -Z6,6 °( 4{ Needs Shift Inspection: Sprinklers: 4 -- - - - - -- Fire Alarm: . Hood .fi Duct: . Monitor: Pre -Fire: ' - Permits: Occupancy Type: - INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT __ pproved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 y3657_ a � < -4" 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: -- ntL -to Cole sP, i ,4.tI4t." -- )0- . — `b ' Z D C . 4 . tUYLtN6 - p kM C . / ± f ' N`T 0 VPLS. — t•A Co AGL. - PTPr- p1C:tr _ d Tare 9• p Inspector: 5/2 Date: g in -/0g iHrs.: `• a V $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department:? Call to schedule a reirispection., ' r \ T.F.D. Form F.P. 113 PERMIT NUMBERS • b . • 4, r { .1 L • July 18, 2008 ernck D. Le z Principal Architect Dear Mr. Johannessen: Allen Johannessen, Plans Examiner Tukwila Building Division 6300 Southcenter Blvd. Suite #100 Tukwila, Washington 98188. RE: Project # D08 -3655 Washington State Liquor Store 14227 International Blvd. Suite "C" Sincerely, MERRICK LENTZ AR TECT MERRICK LENTZ ARCHITECT A R C H I T E C T U R E - P L A N N I N G Thank you for your letter of July 11, copy included, pertaining to this project. Reponses have been prepared and are included . for your continued review. 1. Information has been added to the cover sheet confirming an "M" occupancy with "S -1" storage. Areas are identified and the occupancy count totaled. 2. The exit path is now delineated by a 42" high chain link enclosure fence to separate the exit path from the stockroom area of the store. 3. Emergency exit lighting with battery back -up was and still is indicated on the reflected ceiling plan. 4. The adjacent tenants in this building -are `B" occupancies. Per IBC Table 508.3.3 no separation is required between "B ", "M" and "S -1" occupancies, whether or not the building is provided with fire sprinklers (this building DOES have sprinklers.) Please let me know if you have additional comments or concerns. 1800 - 136th Place NE - Suite 100, Bellevue, WA 98005 t 425 747 3177 f 425 747 7149 mla @mlarch.com I July 11, 2008 Rick Lentz 1800 — 136 Avenue NE, #100 Bellevue, WA 98005 Sincerely, iclotk Brenda Holt Permit Coordinator Enclosures File: D08 -365 • Department of Community Development Jack Pace, Director RE: Letter of Incomplete Application # 1 Development Permit Application D08 -365 WA State Liquor Control Board — 14227 Tukwila International Bl • Jim Haggerton, Mayor Dear Mr. Lentz, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 9, 2008 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. P:\Permit Center\Incomplete Letters\2008\DO8 -365 Incomplete Ltr ti 1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Date: July 10, 2008 Project Name: Washington State Liquor Store Permit #: D08 -365 Plan Review: Allen Johannessen, Plans Examiner • • Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. On the cover sheet provide occupant statistics for this pace that identifies this occupancy as "M" Mercantile with "S1" Storage, show the square footage of the mercantile space and warehouse /storage space. Identify the total occupant count of each individual space with the total occupant for this tenant. 2. Floor plan shows a path with hatched lines to define an exit path. An egress path shall not be allowed to pass through the open storage or warehouse unless the path is a demarcated minimum 44 inch wide aisle defined by full or partial height fixed walls or similar construction that will maintain the required width and lead directly to the exit without obstructions or possibility thereof. Please revise egress plan to show provisions for a protected exit access path. (IBC 1014.2 #2.4) 3. Identify path of egress illumination. Path of egress shall show sufficient illumination of 1 foot - candle at the walking surface leading to the exit discharge doorways. (IBC Section 1006) 4. Additional information shall be required identifying the wall separations to the adjacent tenants. Wall separations shall comply with requirements for this type occupancy (Liquor Store). (IBC Table 508.3.3, Section 311 & Section 705) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. DEPARTMENTS: 2 � $ B ai g i ision Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 41 PERMIT COORD COPY 41/ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -365 DATE: 07 -18 -08 PROJECT NAME: WA STATE LIQUOR CONTROL BOARD SITE ADDRESS: 14227 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 07 -22-08 Not Applicable ❑ No further Review Required DATE: Not Approved (attach comments) DATE: DUE DATE: 08-19-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -365 DATE: 07 -09 -08 PROJECT NAME: WASHINGTON STATE LIQUOR STORE SITE ADDRESS: 14227 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: Buig !vision Pubic W rks �i/A 1- r0-(7b DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 ' PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: 0`100 AIM/ 1- 10 -08 Fire Prevention Structural Incomplete n rV \) V 11/19'° Planning Division ❑ Permit Coordinator DUE DATE: 07 -1 0-08 Not Applicable LiI n Permit Center Use Only INCOMPLETE LETTER MAILED: l 1 ` � LETTER OF COMPLETENESSiM ICED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: DATE: DUE DATE: 08 -07 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: tiplY 1 7 2006 Plan Check/Permit Number: D08 -365 Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued El Revision requested by a City Building Inspector or Plans Examiner Project Name: WA STATE LIQUOR CONTROL BOARD Project Address: 14227 Tukwila International B1 Contact Person: Rick Lentz Phone Number: Summary of Revision: elArr PAS gf.t9Erwa9 ` Nm=s etisf4M 6,17 pEK Sheet Number(s): Al .0 ' 42 "Cloud" or highlight all arias of revision including date of revision Received at the City of Tukwila Permit Center by: • City of Tukwila \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us & 7 E) Entered in Permits Plus on CA-( t s lob • eirv 1 JUL 18 2088 La Piirc.el Name Role Effective Date Expiration Date DOWN, ROBERT H Cancel Date 01/01/1980 Bond Amount DOWN, DIANNE L 4 01/01/1980 206853225 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 TRAVELERS CAS Et SURETY CO 206853225 09/02/2001 Until Cancelled $12,000.00 08/10/2001 3 UNITED PACIFIC INS CO 6853225 09/02/1997 Until Cancelled 09/02/2001 $6,000.00 09/02/1997 2 UNITED PACIFIC U2474654 09/02/1994 09/02/1997 09/02/1997 $6,000.00 09/02/1994 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. RIVER CITY CONSTRUCTION INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company RIVER CITY CONSTRUCTION INC 2539394545 1425 22ND ST NW STE C AUBURN WA 980013334 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 601139256 ACTIVE RIVERCC117OB CONSTRUCTION CONTRACTOR 9/2/1989 7/3/2009 RIVERCC210B4 GENERAL UNUSED Business Owner Information • • Bond Information https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= RIVERCC 1170B Page 1 of 2 07/29/2008 0 FUTURE DRUG STORE R199' R259' 0 SCALE: 1" = 30' -0" NO CHANGE TO EXISTING PARKING, LANDSCAPING, INGRESS OR EGRESS S144TH SITE PLAN 0 15' 30' 60' EXIST FAST FOOD 2,640 SF R182' I i PROJ NOTES SCOPE OF WORK OCCUPANCY CONSTR. TYPE BLD. AREAS ADDRESS OWNER OCCUPANCY I `SEPARATE PERMIT REQUIRED FOR: 4 Methanical �', IectriCal [N�umbing CVGas Piping City of Tukwila BUILDING DIVISION ASSESSOR PARCEL #152504101I FILE OP Permit Na pear review approval Is subject to errors and omissions. Approval of constnuction documents does not ordinance. pt the violation of any adopted � or is acknowledged: o. approved aid Copy By d J Cl Date: TENANT IMPROVEMENT OF 5000 SF SPACE WITHIN EXISTING BUILDING F.R USE AS WS STORE M — MERCANTILE (PUBLIC AREA) 5-1 — STORAGE 2 -5 FULLY SPRINKLERED DRUG STORE LAUNDRAMAT SUITE "G" VIDEO STORE STORAGE TOTAL Rcsy iSiONS _."' r ___----- o changes shall be - made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 15066 5114 5640 5513 2840 52855 City of Tukwila BUILDING DIVISION SEG 56th LLC 845 1 06th AVENUE NE, SUITE 100 BE LEVU , 10 7=18 04 M — 20 SF @ 1/50 = ''O 5—I — 3550 SF ® 1/500 = 12 TOTAL OCCUPANT LOAD = 82 PER IBC TABLE 5083.3, NO OCCUPANCY SEPARATION IS REQUIRED BETWEEN M, B AND 5—I OCCUPANCIES. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 8 2008 Of Tukwila BUILDING_ DIVISION_ SF (B OGG .) SF (B OCC.) SF (M /S— I OGC .) SF (B OGG) SF SF 4221 TUK 1 LA INTERNATIONAL BLVD. SUITE 'C' TUKY'II LA, WASHINGTON 18 168 INCOMPLETE LTR# I RECEIVED CITY OF TI !KWILA Jl1i 1 08 PERMIT CENTER UNPUBLISHED WORK ©2008 MERRICK LENTZ ARCHITECT MERRICK LENTZ ARC ITECT 1800 — 136th Place N.E., Suite 100 Bellevue, Washington 98005 (425) 747 -3177 FAX (425) 747 -7149 E —Mail: mla @mlarch.com REGISTERE A ; - A • I - P_' LENTZ STATE OF ASHINCSON PROJECT NAME WASHINGTON STATE LIQUOR STORE TUKNILA, WASH. DRAWING TITLE SITE PLAN, PROJECT NOTES DATE JULY 1, 2008 DRAWN BY . CHECKED BY REVISIONS . JULY 15, 2008 A I .0 EXIST. SUSP. CEILING NILTY PINS el 24" o.c. O�PIGE WALL SECTION 5/8" GUB EA. SIDE 20 GA. 3 5/8" STEEL STUDS m 16" o.c. SCALE: I /2 "= I' -O" ILLUMINATED EXIT LT' \w/ BATTERY BACK -UP EXIST. CONC. SLAB Et] 4ASES i [L INE OF 8' 1-11G1-1 WALL (FRE STAND ING ) ,/ / 36" HIGH CHECK -OUT STAND I I 0 LIQUOR SALES AREA 1� T 36" HIGH CHECK -OUT STAND ' ==—= -- IBC 1006.3 Illumination emergency p ower. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. electrical In the event of power supply failure, an emergency system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... LAUNDROMAT SUITE "5" 3114 SF NO WORK TO 5E DONE IN THIS SUITE / C,:17444'T - ;LINE of 8' THIGH WALLASES (FRESTANDINGT I I I I I VIDEO RENTAL SUITE "D" 5593 SF NO WORK TO BE DONE IN THIS SUITE I I OFFICE OFFICE WALL SECT. ) oUNTER — 4 30" A.F.F. e 3/0x1/0 HC POCKET DOOR 4 /0x3 / ON. -WAY MIRRO GLASS 7 L _ �J 27' -2) 42" HIGH CHAIN LINK FEN E ENCLOSING EXIT PATH SUPPORT POSTS • 10' o.c. MAX. - TYP. BOLT SUPPORT POSTS TO CONC. FLOOR 44" EXIT PATH F LOOR LAN SCALE: I /8 "= I' -O" iet lol rn PARALLEL TO M RUNNER; 12 GA. WIRE, TYP rn X 12 GA. MIN. HANGER WIRE ® 48" O.G. MAX. 4 NI 8" OF CEILING OR WALL �� DISCONTINUITY; PROVIDE SLACK). ovo- AADDL. WIRE W/I 3" OF A. �� CORNER OF A. FIXTURE; / PROVIDE (2) ADD IL WIR ■+- TO OPPOSITE CORNERS OF F I XTURE (MAY BE 01 �U /4 ,.<. 45 MAX.. TY EXIST. ELEC. PANEL NO SCALE STOCK ROOM 11 II PR3 /0xl /0 DOORS (EXIST.) 0 PR3 /0x1/0 DOORS (EXIST.) X -I rn rn STORAGE 3480 SF NO WORK TO SE DONE IN THIS SUITE C o S in NOTE: ATTACH GRID BRAG ING ASSEMBLY @ 12' o.c. MAX. START FIELD 4' -O" FROM PERIMETER DEMISING WALL. SUSN CILIN 41P J UL 28 2000 .tc°f iia REFER I /Aq.O FOR HANGER WIRE, STRUT AND CONNECTION TO STRUCTURE ABOVE COMPRESSION STRUT PER I /Aq.O. NOTCH AS REG'D FOR CEILING PANEL 12 GA. HANGER WIRE PARALLER TO GROSS TEE, ANCHORED TO MAIN RUNNER - 45 MAX., TYP. NOTE : LIGHTS $ MECH. GRILLS SHALL BE MECH. FASTENED TO GRI D. D CITY%F119VILA .II 1 8 2008 PERMIT CENTER UNPUBLISHED WORK ©2008 MERRICK LENTZ ARCHITECT MERRICK LENTZ ARC ITECT 1800 - 136th Place N.E., Suite 100 Bellevue, Washington 98005 (425) 747-3177 FAX (425) 747 -7149 E -Mail: mla @mlarch.com e REGISTERS A RCFW T �' LENTZ STATE OF WASHINGTO ,3 PROJECT NAME WASHINGTON STATE woo STORE TUKWI LA, WASH. DRAWING TITLE CONSTRUCTION F LOOR PLAN, REFLECTED CEILING PLAN, DATE JULY 7, 2008 DRAWN BY . CHECKED BY . REVISIONS JULY 15, 2008 A2.0 ',..-7 LAUNDROMAT SUITE "5" NO WORK TO 5E DONE IN THIS SUITE f ol I • A i I •• I OFFICE O 1 i XIST. i ii � ae�ii u�caeai� iis �iaa eau ic�eaa�ia4eaa MernaaMEMeaaaa ■iaaeao I ueaaa•• ► -1 1[111111 Q OR ., .► R; ; ; I OC ROO III I i �rzaaaa� i iraea u NIMM MMM miss i i aae �ii I•R/liaU■ ie�iai3ii ■MMNMMMi ... ii' mi Rl�l➢a�e �ar�a �7��� — ... ._.. I 1 BE =L • - (TYP. 19 L. X SUSP. CEILING DETAIL I EX Ia'T'ING SuSP,- .CEILING • +14' -0" A.F. NEW SUSP. CEILING • X14' - 0" A.F.F. g rammes ue aaaa� -- iic ueaaau M- aamma ueMaau - - is ®ars neaaaa� - - - - - - I- aeaea •• M •U — - - - 111:4111 ueaaau -INS OF 42" HIGH rn l BELOW - - EXIT PATH ENCLOSURE - } - - c XIT . I I I I • • I _ I i t ) I i 8 - I ETU FE�U FIXT. EMERGENCY EXIT PATH LT'G I D O R��L w/ BATTERY BACK -UP, PROVIDE MIN. 1 LUMEN AT FLOOR RE E STING TYP. 18 LOC.) SUITE "D" - - -- \TYP 10 LOOS MIN. AS SHOWN, NO WORK TO BE DONE IN THIS SUITE ` , f �— �\ \ � I l OMMMMIMM IMIMMMMOM • 1 S CEILING FLAN , ,I 0 I ) SCALE: I/8 " =1' -O" IEXI7 S OF EGRESS ILLUMINATION MEANS LUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be served by the � 7 =1 b b illuminated at all times the building space means of egress is occupied. y �iix I IBC 1006.2 Illumination level. The means of egress illumination level shall not be less than . level. 4 c.,.,+_.,nrlla at the walking EXIST. SUSP. CEILING NILTY PINS el 24" o.c. O�PIGE WALL SECTION 5/8" GUB EA. SIDE 20 GA. 3 5/8" STEEL STUDS m 16" o.c. SCALE: I /2 "= I' -O" ILLUMINATED EXIT LT' \w/ BATTERY BACK -UP EXIST. CONC. SLAB Et] 4ASES i [L INE OF 8' 1-11G1-1 WALL (FRE STAND ING ) ,/ / 36" HIGH CHECK -OUT STAND I I 0 LIQUOR SALES AREA 1� T 36" HIGH CHECK -OUT STAND ' ==—= -- IBC 1006.3 Illumination emergency p ower. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. electrical In the event of power supply failure, an emergency system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... LAUNDROMAT SUITE "5" 3114 SF NO WORK TO 5E DONE IN THIS SUITE / C,:17444'T - ;LINE of 8' THIGH WALLASES (FRESTANDINGT I I I I I VIDEO RENTAL SUITE "D" 5593 SF NO WORK TO BE DONE IN THIS SUITE I I OFFICE OFFICE WALL SECT. ) oUNTER — 4 30" A.F.F. e 3/0x1/0 HC POCKET DOOR 4 /0x3 / ON. -WAY MIRRO GLASS 7 L _ �J 27' -2) 42" HIGH CHAIN LINK FEN E ENCLOSING EXIT PATH SUPPORT POSTS • 10' o.c. MAX. - TYP. BOLT SUPPORT POSTS TO CONC. FLOOR 44" EXIT PATH F LOOR LAN SCALE: I /8 "= I' -O" iet lol rn PARALLEL TO M RUNNER; 12 GA. WIRE, TYP rn X 12 GA. MIN. HANGER WIRE ® 48" O.G. MAX. 4 NI 8" OF CEILING OR WALL �� DISCONTINUITY; PROVIDE SLACK). ovo- AADDL. WIRE W/I 3" OF A. �� CORNER OF A. FIXTURE; / PROVIDE (2) ADD IL WIR ■+- TO OPPOSITE CORNERS OF F I XTURE (MAY BE 01 �U /4 ,.<. 45 MAX.. TY EXIST. ELEC. PANEL NO SCALE STOCK ROOM 11 II PR3 /0xl /0 DOORS (EXIST.) 0 PR3 /0x1/0 DOORS (EXIST.) X -I rn rn STORAGE 3480 SF NO WORK TO SE DONE IN THIS SUITE C o S in NOTE: ATTACH GRID BRAG ING ASSEMBLY @ 12' o.c. MAX. START FIELD 4' -O" FROM PERIMETER DEMISING WALL. SUSN CILIN 41P J UL 28 2000 .tc°f iia REFER I /Aq.O FOR HANGER WIRE, STRUT AND CONNECTION TO STRUCTURE ABOVE COMPRESSION STRUT PER I /Aq.O. NOTCH AS REG'D FOR CEILING PANEL 12 GA. HANGER WIRE PARALLER TO GROSS TEE, ANCHORED TO MAIN RUNNER - 45 MAX., TYP. NOTE : LIGHTS $ MECH. GRILLS SHALL BE MECH. FASTENED TO GRI D. D CITY%F119VILA .II 1 8 2008 PERMIT CENTER UNPUBLISHED WORK ©2008 MERRICK LENTZ ARCHITECT MERRICK LENTZ ARC ITECT 1800 - 136th Place N.E., Suite 100 Bellevue, Washington 98005 (425) 747-3177 FAX (425) 747 -7149 E -Mail: mla @mlarch.com e REGISTERS A RCFW T �' LENTZ STATE OF WASHINGTO ,3 PROJECT NAME WASHINGTON STATE woo STORE TUKWI LA, WASH. DRAWING TITLE CONSTRUCTION F LOOR PLAN, REFLECTED CEILING PLAN, DATE JULY 7, 2008 DRAWN BY . CHECKED BY . REVISIONS JULY 15, 2008 A2.0