Loading...
HomeMy WebLinkAboutPermit D08-366 - REGENCY REALITY CENTERS - VACANT SPACE - SHELLVACANT SPACE 381 STRANDER L D08 -366 Parcel No.: Address: Suite No: Owner: Name: Address: Phone: 381 STRANDER BL TUICW Tenant: Name: VACANT SPACE Address: 381 STRANDER BL , TUKVVILA WA Cityabf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: NANCY KLUTH Address: 4190 TEANAWAY RD M F , CLE ELUM WA 98922 Phone: 509 - 674 -5969 Contractor: Name: NORTHWEST COMMERCIAL IMPR INC Address: 4190 TEANAWAY RD MF , CLE ELUM WA 98922 Phone: (509)674 -5969 Contractor License No: NORTHCI147RS doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D08 - 366 Issue Date: 08/21/2008 Permit Expires On: 02/17/2009 Expiration Date: 02/21/2009 DESCRIPTION OF WORK: REMOVE /DEMO ACOUSTICAL CEILING, HVAC DUCTWORK, ALL LIGHTING, ELECTRICAL PANEL AND CONDUIT, FLOOR COVERINGS. CONSTRUCT (1) NEW ADA COMPLIANT RESTROOM Value of Construction: $32,100.00 Fees Collected: $1,004.40 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0019 D08 -366 Printed: 08 -21 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: LajbLQS Date: ` V $ gn �—1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be c• plied with, whether specified herein or not. The granting constructio Signatur Print Name: doc: IBC -10/06 City di/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us s not presum ceofw•r Private: Public: Permit Number: D08 -366 Issue Date: 08/21/2008 Permit Expires On: 02/17/2009 ority to violate or cancel the provisions of any other state or local laws regulating d to sign and obtain this developme • : ' t. Date: i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -366 Printed: 08-21 -2008 Parcel No.: Address: Suite No: Tenant: 381 STRANDER BL TURIN VACANT SPACE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -366 Status: ISSUED Applied Date: 07/09/2008 Issue Date: 08/21/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Maintain fire extinguisher coverage throughout. 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Cond -10/06 D08 -366 Printed: 08 -21 -2008 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Combustible material shall not be stored in exits or exit enclosures. (IFC 315.2.2) doc: Cond -10/06 D08 -366 Printed: 08 -21 -2008 0 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 29: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 31: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 32: Walls of corridors serving an occupant load of 30 or more shall be of not less than one -hour fire resistive construction and the ceilings shall not be less than that required for a one -hour fire resistive floor or roof system. (IBC 708.1(4)) (IBC 1016.1 Table 1016.1)) 33: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 34: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 35: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 36: These plans were reviewed by Inspector 512. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** D08 -366 Printed: 08 -21 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to • 'v`• uthority to violate or cancel the provision of any other work or local laws regulating construction or the perfo ce of work. Signature .1/ . _ Date: doc: Cond -10/06 D08 -366 Printed: 08 -21 -2008 SITE LOCATION Site Address: ,cg/ Tenant Name: Property Owners Name: ^� Mailing Address: I 60 ermit is re to be issued who CONTACT PERSON - do we contact when your 6 c- lir t City State Zip E -Mail Address: 4) l� f e L °I (� /� e 6-,4 / f . ��Fax Number: ..S - 6 /60t S Name: Mailing Address: GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping ( Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWI Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Company Name: Mailing Address: Contact Person: E -Mail Address; GINEER OF ARCHITECT OF RI ( Contractor Registration Number: • 101=1111.d. - M !l�_ ►�AZI.0 State III 7 olio (J DC Mil, o rcle\ -eom aits'must be wet stamped by Architect of Record Zi �n Iek Company Name: Mailing Address: Contact Person: E -Mail Address: Q'\Applications\Porms- Applications On Line \3 -2006 - Permit Application.doc Revised' 9 -2006 bh RD - All plans must be Building Permit No Mechanical Permit No. mg /Ga Public Works Project No. For o use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Ass s r ' s Tax No.: J c 1 ?06 G ' •V y ke Number: ,j 2 / Floor: .... Yes 121 ..No City City Day Telephone: :striped by Engineer (AR New Tenant: Day Telephone: / City State Day Telephone: �q Fax Number: .()9 6 2y' / Expiration Date: Am //7 Fax Number— State State Zip City Day Telephone: Fax Number: Zip Page 1 of 6 t lc( BUILDING PERMIT INFORM " nN - 206- 431 -3670 Valuation of Project (contractor's bid price): $ ix Scope of Work (please provide detailed informatio v ect 1 e gavel rc - Gc) (if C c°JcfS 7 4'q OA) Will there be new rack storage? O.... Yes Existing Building Valuation: R.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 2 Floor 3t Floor Floors thru Basement Accessory Structure dGar A Detached Garage Attached Carport Detached Carport. Coy d Uncovered Dt Interior Remodel /073"' Addition to Existing Structure Type of structipn per IBC IBC Y-U ri'�kf�1(J P Type of Occupancy per PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: IN Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: yP Qh' Fixture'TYPe: ' Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) Wash fountain , g �¢ Gas piping outlets I Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain r Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory ! Water Closet �j ,[_ Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent -i ,-- Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment 1 Repair or alteration of drainage or vent piping i Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPIJPERMIT INFORMATION - 206 -431 -3670 PLUMBING AND Company Name: Mailing Address: Contact Person: E -Mail Address: E /J F /fir 41 M'S In Contractor Registration Number. id/ p F5/ L) 4) Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): S-10bed 0 AS PIPIN G ONTRACTOR INFORMATION p, O //.'igir , Building Use (per Int'1 Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: ' • • • / /9 -# Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: tty State Zip �'' Day Telephone: L�/�- t ' v- on Fax Number: , �- • 0 4- 5o77 Expiration Date: Page 5 of 6 BUILDING Signature: Print Name: Mailing Address: Date Application Accepted: - 1 -9 -v Q:\Applications\Porms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh City PERMIT APPLICATION NOTES — Applicable to all permits in this app.>lcation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: Day Telephone: , ��` X ros State Date Application Expires: 11 - 6 7 Staff Initials: u it Zip Page 6 of 6 i Parcel No.: Address: 381 STRANDER BL TUKW Suite No: Applicant: VACANT SPACE Receipt No.: R08 -03034 Payee: NORTHWEST COMMERCIAL IMPROVEMENTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7370 610.50 ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 606.00 000/386.904 4.50 Total: $610.50 Permit Number: D08 - 366 Status: APPROVED Applied Date: 07/09/2008 Issue Date: Payment Amount: $610.50 Initials: WER Payment Date: 08/21/2008 02:42 PM User ID: 1655 Balance: $0.00 6445 08/21 0710 TOTAL 610.50 doc: Receiot -06 Printed: 08 -21 -2008 Parcel No.: Address: 381 STRANDER BL TUKW Suite No: Applicant: VACANT SPACE ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Initials: WER Payment Date: 07/09/2008 10:34 AM User ID: 1655 Balance: $610.50 Receipt No.: R08 -02476 Payment Amount: $393.90 Payee: NORTHWEST COMMERCIAL IMPROVEMENTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7355 393.90 RECEIPT Account Code Current Pmts 000/345.830 393.90 Total: $393.90 Permit Number: D08 - 366 Status: PENDING Applied Date: 07/09/2008 Issue Date: 4625 07 /09 971i TOTAL 445.90 N doc: Receiot -06 Printed: 07 -09 -2008 Project:: Type of In pection: , t `�, Addres u A k ( Date Called: '^ Special Instructions: Date Wanted: 5 �._a -..._a p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION 0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: P Date: �J 2,47 ,Z ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: ,Date: COMMENTS: '1 ) "El fl /' Bu; U ( 9-: p/eJ. /Aim i t , t Of Sis 'T� F. R, The t J e Ol.` N.n 1 'lo ,s cues ce � n S u \ c i ,) , ( 11A4- rJJ �( l0J / _ (el `itA OF I,J, kin-- :421 Requester: A• . SLcle row 0r- h : -.j (it /1 p{ / —` k H ;t- rr -'-l) ckee-- f v C ��.t . I I Project: AC A`S ik-G P Type of Inspection . 4 (emu ; t Xlil ( A Address: 3k' S '‘s trAy .8, Caen: -`, ` Special Instructions: Date Wanted: a.m. Lt. r f — ° r-1 Requester: Phone No: -- — -e 0 08 - -3 4, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. orrections required prior to approval. InspectoC 1 Date: / C El $60.00 REINSPECTION FEE RtQU RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: !Date: tkAiL COMMENTS: Type of Inspection: / J 4))9: l jJ ; j l Am l ki - Oc A /f, p M . Address: 38 / s/ V'. Date Called: Special Instructions: Date Wanted: z Yey )14 ;4* C IC4 4; a.m. ,[1. Requester: - J — AMTS.. cz -/ueY 7 ; i I /ui° r ti t>lCf-- 6 ,h15 sii /V1,ve 1 , Ry,,,,, /5 Project: 5P-- /� 14 /l 1t1' R(L Type of Inspection: / J 4))9: l N Address: 38 / s/ V'. Date Called: Special Instructions: Date Wanted: z --C -ft a.m. Requester: Phone No: C pproved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -36(70 Corrections required prior to approval. In Date: ; -z - r. 60 ' 0 REINSI'ECTIOA FEE RE p UIRED. Prior to inspection, fee must be 'd at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: f f A v / Au Ar I l 9 , i.r ,U D ifl •. S el' G.0J - f4 [ 10. 7-j P_ (t pry ✓�P- P S t J (LI /t/v E 1,) k , n,t. -1) 5 -1,x.: , �? L-c_ ; .1 c. LAi 1 ._ Z P_ & , .- . ) p ai ( 1J .1.A--/ t,J - 61 * LA 3f LJ "ef S TLeie o, `t-a ,P JR) -- 07. C' o 31 t tl 1 (--., r kITJ re pet 6Ve kl 0 7 ,y �" am, Date Wanted: �_� Projec • Project,: -s -tee Type of Inspection: Fr4 � `� Address: QQ Date Called: Special Instructions: rs T 1 (LP `� f ? lace` ,y �" am, Date Wanted: �_� a P m. � Requester: Phone No: k INSPECTION NO. INSPECTION RECORD Retain a copy with permit O oh -3(p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti a Approved per applicable codes. orrections required prior to approval. Inspect AA / 00 Date: v El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: Project � �tA S�A Type of Inspection: , r-,r�AA . .LI Address: A Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: - -41 O? INSPECTION RECORD • Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 0 Approved per applicable codes. Dag -3( PERMIT NO. I (206)431 -3670 Corrections required prior to approval. COMMENTS: p Inspec or: (Date: _ c a 1vf_._F,-J9 [j .e-Jr - 4f9-( K `\-- i ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: 'PTA prilit , ar 'e lo� 4 K EAt.Ti Type of Inspection: 'c fit r 'mi 'milt/6 - e- Address: 30 / s roc-- - Suite #: - Contact Person: L Avit eN b h tfoa Z.nn ek m i Special Instructions: Phone No.: f 115 - 308 - 4 oe - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER • n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: S 0 � rizc 1 C,* 2!, APt ( fry iLlq ' ` 0 l L'E mt. n Oir 1 i, v J cOn CAA. BPS 14 SPA Mika, Ualk 4Att) CtS~nNJ t itl.t gtoutilt `_. Sri►+ Fjr►A i'fij iM _ ��f iJ tL u i i dl iiE= r f Inspector: i /GO- Date: Nzi3. 1 Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project Info Project Address ; , / = Date f V! /�!�� Z /. /. W 2 i For But ding ' epartment Use s ` C oP - � • Y Applicant Name: 1 �. / f 4 A pplicant Address / l „ ,(ti _:--...77 Applicant Phone: 6/ ,te 7 f►! Project Description • New Building • Addition ii Alteration `' N,{uYed Refer to WSEC Section 1513 for controls and commissioning regl s: - • • 1 t P Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis. _ (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) No changes are being made to the lighting IN Less than 60% of the fixtures new, installed wattage not increate�d� &eia elbs 9titrrnged. cy ,� a , Location (floor /room no.) Occupancy Description Allowed Watts .er ft2** �' own) ■ Area in ft Allowed x Area MN znne Ci:. Of .r. � . . Watts r roposed ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA s !„ . T�;,"I ��� Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture r, Watts r roposed V Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts CITY OF TUKWILA - BUIG DIVISION I r 2606 Wasington State Nonreside ergy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage • I'erior Lighting Summary LTG -INT C0 PL IV Revised July 2007 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. Foi proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED JUL 092008 1)08- 34(9 PERMIT CENTER Use' LPA` (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 7 •" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail' ", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall'•" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: Warehouses, storage areas or aircraft storage hangers Other O O lifii Qualification Checklist Note: If occupancy type is "Ott1 fixture answer is the _ •, ,o ures in � ,,e� the sp 4 - , ,' t i i k_,..) bre 3e. Clearly indicate - setsp-ces on plans.t� qualified, do LPA Calculations. • Lighting Fixtures: (Section 1SA 1 9 • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. - 2. Metal Halide with a) reflector b) ceramic MI lamps <= 150w c) electronic ballasts 3. LED lights. CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonreside ergy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 -9 Unit Llgnting Power Allowance no for Table 1 5- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft'. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /fi of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 1 I? Pr 'vid�"d that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for �� computing the interior Unit Lighting Power How ce, e flo. , e of c d by racks plus the vertical face area (access side only) of the racks. The height allowance def n foo ote ppplig �`,,: t h loo area not covered by racks. Use LPA (W /sf) Use1 LPA (W /sf) Automotive tacility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and tire stations° 1.0 Cafeterias, fast food establishments', restaurants /bars' 1.3 Post office 1.1 Dormitory 1.0 Retail'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet /conference /exhibition hallr." 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified r laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0 Laundries 1.2 Libraries' 1.3 Plans Submitted tor Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum FontnntPC fnr Tahlo 15_1 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers O Other 'Lighting Qualification Checklist Fixtures: • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- indicate these spaces on plans. If not qualified, do LPA Calculations. tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TART P 1C_• ti. i+ I i..i..;.... Cl.......... nn_...____ •. r... CITY OF TUKWILA - BUILDING DIVISION \"o 6 Wasington State Nonreside 'nergy Code Compliance Form erior' Lighting; Summary_(back 2006 Washington State Nonresidential Energy Code Compliance Forms L) Revised July 2007 1) In cases in which a general use.and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparabfle use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. + 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. CITY OF TUKWILA - BUIG DIVISION 2006 Washington State Nonresid nergy Code Compliance Form fighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Date Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) ** From Table 15 -1 based on exceptions listed in footnotes r Revised July 2007 Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 04 -02 -2009 NANCY KLUTH 4190 TEANAWAY RD M F CLE ELUM WA 98922 RE: Permit No. D08 -366 381 STRANDER BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 05/30/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. D08 -366 city of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 - 3670 • Faxf 2Oh- G 71 -%6f August 4, 2008 Nancy Kloth 4190 Teanaway Road MF Cle Elum, WA 98922 • epartme t of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Application Number D08 -366 Vacant Space — 381 Strander Bl Dear Ms. Kloth: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Public Works Department. At this time the Building, Fire and Planning Departments have no comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Brenda Holt Permit Coordinator encl File No. D08 -366 P:\Permit Center\ Correction Letters\2008\D08 -366 Correction Ltr #1.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 DATE: July 28, 2008 PROJECT: Vacant Space TI 381 Strander Blvd. (P:Joanna /Comments 1 D08 -366) PUBLIC WORKS DEPARTMENT COMMENTS www.ci.tukwila.wa.us Development Guidelines and Design and Construction Standards REVIEW #: 1 PERMIT NO: D08 -366 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The program requires elimination or control of any cross - connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The City has determined that the building at the above address has deficiencies on the domestic water system line and possible deficiencies on fire prevention and landscape irrigation lines. Since Public Works does not have adequate information about your fire prevention and landscape irrigation line in the City database, these issues need to be resolved. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter for premise isolation. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works highly recommends a power supply be provided for the Hot Box. Please specify backflow size, make, and model number. Submit RPPA cut sheet and circle the backflow you plan to install. b) Fire Line It appears that the subject building has a fire sprinkler system. However, Public Works does not have any records of fire backflow in our database. Show on plans location of existing DDCVA and submit passing backflow test report. If the backflow is not a testable device, it shall be replaced with a DDCVA per City of Tukwila Standard Detail WS 15 (2 of 2). Fire Department Connection (FDC) shall have locking Storz caps manufactured by Knox and can be ordered through the Tukwila Fire Department. c) Landscape Irrigation Public Works does not have any records of irrigation backflow in our database. If one exists, show its location on the plan, have it tested by a certified tester, and submit passing test results to Public Works. Is there an irrigation deduct water meter and does it have a remote readout? If not, the existing deduct meter shall be replaced or updated with a TRPL register that is compatible with the Sensus Automatic Reading System. If you need any assistance in locating existing water meter(s) and backflow(s) on the site, please contact Mr. Bryan Still, Public Works Water Superintendent, at (206) 433 -1864 to schedule a meeting at your site. I have enclosed Development Bulletin C5 that describes the design and installation requirements for cross connection control. July 28, 2008 Regency Realty Centers 1601 114 Avenue S, #B5 Bellevue, WA 98004 RE: Vacant Space Tenant Improvement 381 Strander Blvd., Tukwila WA Permit No. D08 -366 To Whom It May Concern: ID In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross - connection control program to protect the public water system from contamination via cross - connection. The program requires elimination or control of any cross - connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The City has determined that the building at the above address has deficiencies on the domestic water system line and possible deficiencies on fire prevention and landscape irrigation lines. Since Public Works does not have adequate information about your fire prevention and landscape irrigation line in the City database, these issues need to be resolved. d) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent water meter for premise isolation. Installation at another location requires the Public Works Director's approval. The RPPA shall be installed in a Hot Rock/Box or equal freeze protection enclosure anchored to a minimum 4" thick concrete pad. Public Works highly recommends a power supply be provided for the Hot Box. Please specify backflow size, make, and model number. Submit RPPA cut sheet and circle the backflow you plan to install. e) Fire Line It appears that the subject building has a fire sprinkler system. However, Public Works does not have any records of fire backflow in our database. Show on plans location of existing DDCVA and submit passing backflow test report. If the backflow is not a testable device, it shall be replaced with a DDCVA per City of Tukwila Standard Detail WS15 (2 of 2). Fire Department Connection (FDC) shall have locking Storz caps manufactured by Knox and can be ordered through the Tukwila Fire Department. 39 Landscape Irrigation Public Works does not have any records of irrigation backflow in our database. If one exists, show its location on the plan, have it tested by a certified tester, and submit passing test results to Public Works. Is there an irrigation deduct water meter and does it have a remote readout? If not, the Regency Realty Centers Page 2 July 28, 2008 • existing deduct meter shall be replaced or updated with a TRPL register that is compatible with the Sensus Automatic Reading System. If you need any assistance in locating existing water meter(s) and backflow(s) on the site, please contact Mr. Bryan Still, Public Works Water Superintendent, at (206) 4334864 to schedule a meeting at your site. I have enclosed Development Bulletin C5 that describes the design and installation requirements for cross connection control. The Public Works Director will withhold issuance of the Vacant Space Tenant Improvement permit until the Permit Center receives plans for installation or a bond for installation of required backflow(s). If you opt to install, you may install under a separate permit or under a revision to this Tenant Improvement permit D08 -366 application. If you opt to install under the Tenant Improvement permit, you must supply the installation plans consisting of a schematic that clearly shows the location of the domestic water meter in relationship to the property line(s) and the building, size of water meter, connections to the water main, and service to the property together with a construction cost estimate to the Permit Center as a revision to the Tenant Improvement permit application. Installation of items la, lb and lc will trigger a Public Works Type C Construction Permit, which has a progressive fee. For a Type C permit, Public Works collects a base application and plan review fee ($250.00 plus 2.5% of construction cost for backflow installation) when the application or revision to this TI is submitted. An additional 2.5% of construction cost for backflow(s) installation will be assessed at the time of permit issuance. If you opt to bond for the installation, you must provide the following to the Permit Center: 1) an original design and installation estimate, 2) a bond for 150% of the design and installation cost, and 3) a letter stating your intent to install the subject backflow(s) by a certain date. This must be done before the Permit Center issues the permit. I have enclosed Public Works Bulletin 1 to help you. Please call Mike Cusick, Public Works Senior Water and Sewer Engineer, at (206) 431 -2441. Sincerely, Joanna Spencer Development Engineer JS:lw enclosures: Public Works Bulletins #A -1 and C5 Permit Application cc: Nancy Kloth (P:Joanna /Letter Regency Realty Centers 072808) • July 11, 2008 Nancy Kloth 4190 Teanaway Road MF Cle Elum, WA 98922 RE: Letter of Incomplete Application # 1 Development Permit Application D08 -366 Vacant Space — 381 Strander B1 Dear Ms. Kloth, Enclosures File: D08 -366 Brenda ' o Permit Coordinator • PAPermit Center\lncomplete Letters12008\D08 -366 Incomplete Ltr # 1.DOC jem Department of Community Development Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 9, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. Jim Haggerton, Mayor In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenwer service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. ncerely, 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Date: July 10, 2008 Project Name: Vacant Space Permit #: D08 -366 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide a regular size plan set that is drawn to scale. Reduced drawings shall not be accepted. 11 x 17 sheets are the minimum size sheet accepted as long as the documentation and design is to scale and lettering shall be legible. (IBC 106.1.1) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. Joanna Spencer - Re: 381 Strander TI From: Bryan Still To: Joanna Spencer Date: 07/10/2008 9:05 am Subject: Re: 381 Strander TI CC: Han Kirkland Hi Joanna, This is a strip mall with several tenants and multiple meters. It is the strip with Zoopa's. We need them to review their backflow records we are not showing much in that complex. I have a meter listed for 375 Strander and I believe it serves 381. Fire no records they have sprinklers. Irrigation no records they have irrigation. Need RPPA on domestic No deduct meters. Thanks Bryan »> Joanna Spencer 07/09/2008 4:51 PM »> Bryan, Are they current on their backflows ? Thanks, Joanna ACTIVITY NUMBER D08-366 PRO.BCT NAME Vacant Space SITE ADDRESS 381 &rander Blvd DATE 08/14/08 Original Ran Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Is Issued D B'ARTM BV TS Buildi g DOon Public Works DETBRMINATI N OFCOMPLETBVESS (Tues., Thurs.) Complete Comments REVIBWBR'SINITIALS Documents/routing ip.doc 2-28-02 PLAN REVI BIV /RO U TI N G SU P • Tf Fire Prevention Structural Incomplete n Structural Review Required n Raining Division ❑ ❑ Permit Coordinator n No further Review Required � l DUE DATE 08/19/08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAI L®: LETTER O F CO M PLETBV ESS MAI L®: Departments determined incomplete: Bldg ❑ Fre ❑ Ping ❑ PW ❑ Staff Initials TUBSITHURSROUTING: Please Route REVIEWBR'S INITIALS DATE DUE DATE 09/16/08 APPROVALS O CO RRBCTI O N S Approved Approved with Conditions❑ Not Approved (attach comments) ❑ Notation: DATE Permit Center Use Only CO WT1 O N LETTER MAI LID: Departments issued corrections Bldg ❑ Fre ❑ Ping ❑ PW ❑ Staff Initials ACTIVITY NUMBER: D08 -366 DATE: 07 -15 -08 PROJECT NAME: VACANT SPACE SITE ADDRESS: 381 STRANDER BL Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: �'7� ���` �1 ge Bull ingC7i�Nsion Public o f i 1_ , ik i, 3 f � ) t' Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 "PERMIT COORD COPY 0 PLAN REVIEW /ROUTING SUP Fire Prevention Incomplete n TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: n n ❑ Permit Coordinator n Planning Division DUE DATE: 07 -17-08 Not Applicable ❑ Permit Center'Use Only ' : INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DATE: n DUE DATE: 08-14-08 Approved ❑ Approved with Conditions n Not Approved (attach comments) Vn Notation: REVIEWER'S INITIALS: Permit Center Use. Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW Staff Initials: C/ DEPARTMENTS: Bui g Ives o �J Public Works "EMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D08 -366 PROJECT NAME: VACANT SPACE SITE ADDRESS: 381 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # DATE: 07 -09 -08 Revision # After Permit Issued NOD AV/ 11 Fire Prevention IR --1� Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete n i Kit 140-°6 Planning Division lb Permit Coordinator DUE DATE: 07-1 0-08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 n DATE: DUE DATE: 08-07 -08 Not Approved (attach comments) n DATE: n Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Revision # • City of Tukwila Response to Incomplete Letter # Response to Correction Letter # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: VACANT SPACE Project Address: 381 Strander B1 Contact Person: Nanc Kloth Summary of Rev%on: AlinnW ala Sheet Number(s): / reA) / "Cloud" or highlight all areas of revision including date of revision � C =30'-- 4' 4/0 J �1 Received at the City of Tukwila Permit Center by: /Entered in Permits Plus on 000 \applications\forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Plan Check/Permit Number: D08 -366 Phone Number: D 7 - RECEIVED CRY OF TUKWI A AUG 1'4 2008 PERMrT t;Enr� aely/ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7// ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: VACANT SPACE Project Address: 381 Strander B1 Contact Person: Nancy K1th \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Plan ChecWPermit Number: D08 -366 1 2008 JUL ��hN117 GENTEh Phone Number: 5 j Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: l ci Entered in Permits Plus o ( KI Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 OP Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 / ,16 Water closet, tank or valve, >1.6 GPF 8 4 1411King County Department of Natural Resources and Parks Wastewater Treatment Division Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type j ti" t►eet Add es a' /d. tale wne State ZIP •V / 7 u s N e Subdivision Name,:cDv ie°� /r it Z City or Sewer District Block # Date of Connection Building Name ,P # i - r i/ / / Side Sewer Permit # Owe ) 7 v' ^'G ' 767-?9‘3 Owne s Phone Num er with Area Code) Credit for a demolition may be given under some circumstances. Subdiv. # (sag ) 6 „ 761 ,„ C�' U ! _ „ � E , � i y , molition of pre-existing building? ❑Yes No Property Contact Phone Number (with Area Code) as building on Sanitary Sewer? Yes ❑ No Owner's Mailing A dress Was Sewer connected before 2/1/90? D Yes WhNo ewe_ 5 > • /Ve- ✓vr- ffefore 4)5 A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 L • DOB- 3(0(0 RCE • For King County Use Only Account # No. of RCEs Monthly Rate Property Tax ID # AVID E ! i 6q Party to be Bill e (if different from owner) Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? D Yes oNo B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Proce s: () fine ergm/ sir/0/11 Estimated Wastewater Discharge: of l3 j is MteGallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B 0 ,qv White - Kino County Yellow - Local Sewer Aoercv P nk - Sewer Cusio re JUL 092 PERMIT CENTER ?e6400 f- /1ne- RCE Va re5 rev L oic Ua *o m RCE 51192 10 // ' .va r /rcr 1 Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should • - referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is co rect. I /erstand that : r .: acity charge levied will be based on this information and any deviation will require resubmission of orrer data fo1 r -1 . /� ' 1. on of a revised capacity charge. Signature of Owner / Representativ- di, , all Date , Print Name of Owner /Representative _ .� /g 1f4 L/ •iA• Name Role Effective Date Expiration Date WIBBELMAN, LAUREN E Cancel Date 01/01/1980 Bond Amount WIBBELMAN, LOU ANN 7 01/01/1980 SD8696 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 CBIC SD8696 11/02/2001 Until Cancelled 09/22/2008 $12,000.0011 /16/2001 6 CBIC SD8696 07/11/200111/02 /2001 $6,000.00 07/26/2001 5 AMWEST SURETY INS CO 1299320 12/10/1997 Until Cancelled 08/07/2001 $6,000.00 4 AMWEST SURETY INS CO 1299320 12/10/199412/10 /1997 $6,000.00 3 UNITED PACIFIC U144148412/10/198912/10/1994 $6,000.00 Untitled Page General /Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County NORTHWEST COMMERCIAL IMPR INC 5096745969 4190 TEANAWAY RD MF CLE ELUM WA 98922 KITTITAS Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 600620338 ACTIVE NORTHCI147RS CONSTRUCTION CONTRACTOR 12/10/1986 2/21/2009 COMMEI`158RS GENERAL UNUSED Business Owner Information ID • Bond Information https: / /fortress. w a. gov /lni/bbip/Detai 1. aspx ?License= NORTHCI 147RS Page 1 of 2 08/21/2008 NO 11ci l -GS J.Ik 2d 1 e0/1.01 1-0 r,RAINN: .!Z GHEGK: GP ..NOB NO 5020 GENERA:, N TES L ALL CONSTRUCTION SHALL CONFORM TO THE 2006 EDITION OF THE INTERNATIONAL BUILDING CODE 2. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THESE PLANS AND PROJECT SPECIFICATIONS. 3. GENERAL CONTRACTOR IS RESPONSIBLE FOR PERMITS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN THE PLANS AND SPECIFICATIONS NOTIFY THE ARCHITECT IMMEDIATELY. 4. SEPARATE PERMITS ARE REQUIRED FOR, BUT NOT LIMITED TO, PLUMBING, ELECTRICAL, SIGNS, REFRIGERATION EQUIPMENT, SEWER HOOK -UPS AND OFFSITE IMPROVEMENTS, SUCH AS SIDEWALKS, CURBS AND GUTTERS, WATER MAINS, CURB CUTS FOR DRIVEWAYS, STORM DRAINAGE, STREET LIGHTING AND STREET SIGNS. THE BUILDING INSPECTION/PERMITS SECTION WILL BE RESPONSIBLE FOR THE INSPECTION AND ENFORCEMENT OF MQUIREMENTS OF BUILDING, PLUMBING, HEATING, ELECTRICAL, OCCUPANCY, FIRE RESISTIVE CONSTRUCTION, PARKING, SIGNS AND ANY OTHER BUILDING REQUIREMENTS NOT SPECIFICALLY PROVIDED FOR BELOW. SPECIAL INSPECTORS SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO CONSTRUCTION. 6. THE BUILDER'S COPY OF THE APPROVED SET OF PLANS MUST BE AVAILABLE TO INSPECTOR'S AT THE JOBSITE 1. FIRE SAFETY DURING CONSTUCTION SHALL COMPLY WITH 2006 INTERNATIONAL FIRE CODE CHAP 14, THERE THE CODE STATES "WHERE REQUIRED ". SUCH SECTIONS .ARE REQUIRED UNLESS A WRITTEN EXEMPTION TO THE SECTION HAS BEEN SUBMITTED TO 114E DEPARTMENT AND APPROVED. a FINISH FLOOR REFERENCE DATUM EQUALS (0' -0 "). REFER TO TOPOGRAPHIC SURVEY FOR ACTUAL SITE ELEVATION. 9. ALL DIMENSIONS ARE TO FACE OF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES UNLESS NOTED OTHERWISE. 10. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD OF ANY SPECIES OR FOUNDATION GRADE CEDAR OR REDWOOD. ALL MARKED BY AN APPROVED TESTING AGENCY. 11. ALL WOOD FORMS USED FOR CONCRETE, IN THE GROUND OR BETWEEN FOUNDATION SILLS AND THE GROUND SHALL BE REMOVED. 12. CONCEALED SPACES 2006 SEC 111- PROVIDE HORIZONTAL FIREBLOCKING IN ALL WOOD FRAME WALLS AT I0' -0" ON CENTER AND WHERE FRAME WALLS PENETRATE CEILINGS. FIREBLOCK ENCLOSED ATTIC SPACES SHALL BE DIVIDED INTO HORIZ. AREAS NOT EXCEEDING 3000 SF. OR NOT REQUIRED IF BUILDING IS SPRINKLERED 2006 IBC 111A. DRAFT STOP CONSTRUCTION: THESE AREAS SHALL BE DIVIDED BY PARTITIONS EXTENDED FROM THE CEILING TO THE UNDERSIDE OF THE ROOF DECK MATERIAL SHALL BE 1/2" GYP. BD. OR 3/8" PLYWD. OR OTHER APPROVED MATERIAL. OPENINGS N THE PARTITIONS SHALL BE PROTECTED BY SELF CLOSING WITH AUTO LATCHES, PER 2006 IBC 111.3.1 13. AN AUTOMATIC SPRINKLER SYSTEM THAT CONFORMS WITH ALL RECOMMENDATIONS OF AN APPROVED RATIN BUREAU AND NFPA PAMPHLET NO. 13 AND IS CONNECTED TO AN ALARM RECEIVING FACILITY AS APPROVED BY THE CITY OF TUKWILA FIRE MARSHALL SHALL BE INSTALLED. ACTIVATION OF THE FIRE SPRINKLER SYSTEM SHALL ACTIVATE THE FIR= ALARM SYSTEM. GUARDS TO BE PROVIDED THROUGHOUT PREMISES TO PROTECT HEADS FROM ACCIDENTAL IMPACT. A SEPARATE PERMIT AND PLAN REVIEW SUBMITTAL IS REQUIRED FOR 714E INSTALLATION OF THE FIRE SPRINKLER SYTEM. ALL SHOP DRAWINGS SHALL BE SUBMITTED AND APPROVED BY THE FIRE MARSHALL PRIOR TO THE START OF INSTALLATION. ALL WORK INCLUDING DESIGN AND INSTALLATION SHALL BE PERFORMED BY A WASHINGTON STATE LICENSED FIRE SPRINK.ERD CONTRACTOR 14. THE BUILDING SHALL BE PROTECTED BY AN APPROVED AUTOMATIC FIRE ALARM SYSTEM AND EMERGENCY vOICE /ALARM COMMUNICATION SYSTEM. A SEPARATE PERMIT ANP PLAN REVIEW SUBMITTAL IS REQUIRED FOR THE INSTALLATION OF THE FIRE ALARM SYSTEM. WORK SHALL NOT COMMENCE UNTIL THE PLANS HAVE BEEN APPROVED AND 714E PERMIT HAS BEEN ISSUSED. 15. PROVIDE (1) 2A -10BC FIRE EXTINGUISHER (WALL MOUNTED) FOR EACH 3000 SQUARE FEET OF FLOOR AREA. MAXIMUM TRAVEL DISTANCE SHALL BE 15 FEET TO AN EXTINGUISHER TOP OF CABINET • 60" APP. MAX. PORTABLE FIRE EXTINGUISHER HAYING A MINIMUM RATING CLASS 'K' SHALL BE INSTALLED WITHIN 30 FEET OF COMMERCIAL FOOD HEAT- PROCESSING EQUIPMENT AS MEASURED ALONG AN UNOBSTRUCTED PATH OF TRAVEL IN ACCORDANCE WITH 2006 INTERNATIONAL FIRE CODE SEC 906. (PROVIDE MINIMUM 1 FIRE EXTINGUISHER PER TENANT LEASE SPACE.) . EXTINGUISHERS SHALL BE INSTALLED IN CABINETS AT CERTAIN LOCATION IF REQUIRED BY THE CITY. 16. ALL DECORATIVE MATERIALS ARE REQUIRED TO BE MAINTAINED IN A FLAME - RETARDANT CONDITION. POST "NO SMOKING" SIGNS IN ACCORDANCE W/ WASHINTON STATE SMOKING IN PUBLIC PLACES ACT 10.1601450 11. EXPOSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE WALL OR CEILING SURFACE FINISH 2006 1.13C. 1193. AT BUILDING ENVELOPE WHERE INSULATION IS INDICATED ON THE PLANS, SECTIONS AND DETAILS, PROVIDE A FIR= RESISTIVE FOIL FACED INSULATION OR VAPOR BARRIER AT WARM FACE OF INSULATION. 18. PROVIDE BUILDING ADDRESS ON EXTERIOR FACE OF BUILDING IN THE LOCATION ILLUSTRATED ON PLANS, LETTERING AND / OR NUMERALS TO BE 12" NIGH MINIMUM. SYMBOLS SHALL BE OF HIGH DENSITY STYROFOAM WITH METALLIC OR LAMINATE FACE. LEASE UNITS TO BE PROVIDED WITH LETTERS OR NUMBERS OVER EACH ENTRY DOOR LETTERING TO BE APPROVED BY ARCHITECT PRIOR TO APPLICATION. LAYOUTS SHOWN FOR LEASE SPACES ARE PRELIMINARY ONLY AND ARE FOR PURPOSES OF ASSIGNING ADDRESSES, DETERMINING EXIT REQUIREMENTS, AND LOCATING TOILET ROOMS. FINAL LAYOUT TO BE SUBMITTED AS TENANTS ARE SELECTED. PROVIDE ILLUMINATED EXIT SIGNS AS INDICATED ON THE REFLECTED CEILING PLAN AND SPECIFICATIONS. LEASE SPACES REQUIRING SEPARATE SANITYARY FACILITIES FOR EAC14 SEX WILL BE INDICATED ON TENANT IMPROVEMENT. 19. MECHANICAL, ELECTRICAL, PLUMBING, LIGHTING 70 BE DESIGN BUILD. CONTRACTOR RESPONSIBLE FOR ALL PERMITS AND APPROVALS. ELECTRICAL: ELECTRICAL RESISTANCE HEAT OR ROMEX WIRING IS NOT ALLOWED. MECHANICAL:TOILET ROOMS SHALL HAVE SEPARATE AND INDIVIDUAL EXHAUST SYSTEMS IN SEPARATE SHAFT 2006 INTERNATIONAL MECHANICAL CODE CHAP 5.714E MECHANICALLY OPERATED EXHAUST SYSTEM SHALL BE CONNECTED DIRECTLY TO THE OUTSIDE, AND 714E POINT OF DISCHARGE SHALL BE AT LEAST 3' FROM ANY OPENING WHICH ALLOWS AIR ENTRY INTO OCCUPIED PORTIONS OF THE BUILDING. THE MECHANICAL EXHAUST SYSTEM SHALL PROVIDE A MINIMUM OF ONE AIR G -IANGE EVERY 15 MINUTES. TOILET ROOMS MAY BE UNDER COMMON SYSTEM IF SYSTEM HAS NEGATIVE AIR PRESSURE IN ALL DUCTS. FIRE /SMOKE DAMPERS SHALL BE INSTALLED IN DUCTS PENETRATING PROTECTIVE ELEMENTS OF FIR= RATED CORRIDOR WALLLS AND CEILINGS PENETRATION OF FIR= RESISTIVE ASSEMBLIES SHALL BE PROTECT PER 2006 IBC SEC 112. TYPES OF MATERIALS AND PROTECTIVE SYSTEMS SHALL BE DESIGNED AND APPROVED UNDER DEFERRED SUBMITTAL. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT (I.E. NO DEAD BOLTS, SURFACE BOLTS, THUMB SCREWS, ETC .). 2006 IBC 100818 THE MAIN EXIT ONLY MAY HAVE A KEY LOCKING DEVICE IF THERE IS A SIGN ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." WHEN UNLOCKED, THE DOOR SHALL BE FREE TO SWING WITHOUT THE USE OF ANY LATCHING DEVICE. AUTOMATCI FLUSH BOLTS ARE ALLOWED ON PAIRS OF DOORS, PROVIDEPTHE DOOR WITH THE FLUSH BOLT HAS NO KNOBS OR SURFACE- MOUNTED HARDWARE, AND THE UNLATCHING OF ANY LEAF REQUIRES ONLY A SINGLE OPERATION 2006 IBC 1008183. ALL EXTERIOR EXIT DOORS WITH AUTOMATIC CLOSERS SHALL HAVE A MAXIMUM OPENING FORCE OF 8 1/2 POUNDS(5 POUNDS FOR INTERIOR DOORS) CONTRACTOR TO VERIFY THAT ALL GLAZING UNITS USED IN HAZARDOUS AREAS 2006 IBC. 24063 SHALL PASS THE TEST REQUIREMENTS OF CPSC 16 CFR 1201, 2006 IBC 2406.11 ALL DOORS 51-1ALL SWING TO THE FULLY OPEN POSITION WHEN AN OPENING FORCE NOT TO EXCEED 30LB8 IS APPLIED TO 744E LATCH SIDE.ROOF DRAINS AND GUTTERS SHALL BE CONNECTED TO THE SITE DRAINAGE SYSTEM. FOOTING DRAINS TO BE CONNECTED TO THE SITE DRAINAGE SYSTEM. 20. CONTRACTOR SHALL COORDINATE INSTALLATION OF IRRIGATION LINES AND SLEEVES AT ALL PAVEMENT AREAS. DE INF 2006 INTERNATIONAL BUILDING 2006 INTERNATIONAL FIRE CODE 2006 UNIFORM PLUMBING CODE 2006 WASHINGTON STATE ENERGY CODE 2006 INTERNATIONAL MECHANICAL CODE WASHINGTON STATE AMENDMENTS JECT CT RY ARCI- 11TECT. CPA + PIRSCHER ARCHITECTS, INC. 20011 BALLINGER WAY NE STE 200 / PO BOX 55429 SEATTLE, WA 98155 PHN: (206) 368 -9668 F: (206) 368 -9558 CONTACT: JILL ZULON CONTRACTOR NCI CONSTRUCTION 41W TEANAWAY RD. MIDDLE FORK, CLE ELUM, WA 98922 P: 509 - 614 -5969 F: 509 -614 -1625 CONTACT: LAUREN WIBBELMAN CLIENT. NCI CONSTRUCTION 41W TEANAWAY RD. MIDDLE FORK, CLE ELUM, WA 98922 P:509- 614 -5969 F :509 -614 -1625 CONTACT: LAUREN WIBBELMAN 381 STRANDER BLVD. TUKWILA, WA 98188 IPELVITTIT SET DEFERRED SUBMHTTALS: MECHANHCAL, ELECTRICAL, PLUMBHNG, ALARM, TENANT IMPROVEMENT REVIEWED FOR CODE COMPLIANCE APPROVED A'.113 1 8 2008 City Of 1 1 ; a E GILDING DI 15roI d LS ROOM SYMBOL OFFICE < ROOM NAME ROOM NUMBER 101 1A2 950 SQFT. BUILDING SECTION SECTION IDENTIFICATION LOCATED ON SHEET- WALL SECTION SECTION IDENTIFICATION LOCATED ON SHEET_ DETAIL DETAIL IDENTIFICATION LOCATED ON SHEET INTERIOR ELEVATION ELEVATION IDENTIFICATION LOCATED ON SHEET ROOM MATERIAL CODES 187 No FLOOR/BASE 2nd No WALLS/WAINSCOT 3rd No CEILING CEILING HEIGHT SQUARE FOOTAGE GRID MARKERS LETTERS IN ONE DIRECTION NUMBERS IN THE OTHER DOOR SYMBOL POOR NUMBER WALL SYMBOL WALL IDENTIFICATION WINDOW SYMBOL � < WINDOW IDENTIFICATION MATCI -I L INE SHADED PORTION IS THE SIDE CONSIDERED CENTER LINE PROPERTY LINE CENTER LINE OF STREAM �11 EXISTING CONTOUR x--11 'i °' ORATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping P+ii., ..l "I%ateu,fin NORTH ARROW ELEVATION MARKER FINISH GRADE ELEVATION TOP OF CURB BUILDING DIVISION TOP OF PAVEMENT NEW CONTOUR REVISION CLOUD IDENTIFYING NUMBER 1.10.060 ABD NS AND L ANGLE • AT CENTERLINE DIAMETER OR ROUND L PERPENDICULAR • POUND OR NUMBER A8. ANCHOR BOLT ACOUS. ACOUSTICAL A.P.F. ABOVE FINISH FLR AGGR AGGREGATE ALUM. ALUMINUM ANOD. ANODIZED APPROX. APPROXIMATE ARCH. ARCHITECTURAL ASPH. ASPHALT BD. BLDG. BLK BLK'G. 1 t1. SOT. B1.1.R. BOARD BUILDING BLOCK BLOCKING BEAM BOTTOM BUILT UP ROOF CAB. CABINET C.B. CATCH BASIN GEM. CEMENT CH. CHANNEL C.J. CONTROL JOINT CLG. CEILING CLR CLEAR C.O. CLEAN OUT COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONSTR. CONSTRUCTION CONT. CONTINUOUS C.T. CERAMIC TILE CTR CENTER CTSK COUNTER SUNK DBL. DEPT. DET. DIA. DIM. DN. DR D.S. DWG. E. EA. E.IF .S. E.J. EL. ELEC. ELEV ENCL. E.P. DOUBLE DEPARTMENT DETAIL DIAMETER DIMENSION DOWN DOOR DOWNSPOUT DRAWING EQ. EQUIP. EXIST. EXPO. EXT. F.O.I.C. F.D. F.E. F.N. FIN. FLASH. FLR FLUOR. FOUND. FRKG. FT. FTG. PURR GA. GALV. G.C. GL. GND. GR. GP. GJJJ.B. GYP. 1-1DWR. HDCP. 14DWD. H.B. H.C. NM. HORIZ. HR HT. INST. INSUL. INT. LAM. LB. LOC. MATL. MAX. MFR M.N. EAST MECI -I. EACH MIN. EXTERIOR INSULATION MISC. FINISH SYSTEM MTD. EXPANSION JOINT MTL. ELEVATION ELECTRICAL N. ELEVATOR NJ.C. ENCLOSURE NO. ELECTRICAL PANEL N.T.S. EQUAL OG. EQUIPMENT 0/ EXISTING OPP. EXPOSED EXTERIOR PL. FURNISHED BY OWNER PLYWP. INSTALLED BY CONT'R P.P. FLOOR DRAIN PLAIN FIRE EXTING- UISHER R FIRE HYDRANT RD. FINISH REC. FLASHING REF. FLOOR REINF. FLUORESCENT REQ'D. FOUNDATION RM. FRAMING FOOT OR FEET S. FOOTING S.C. FURRING SCI GAUGE SHT. GALVANIZED SHT'G. GENERAL CONTRACTOR SIM. GLASS SPEC. GROUND SQ. GRADE STD. GROUP STL. GYPSUM WALL STOR BOARD STR,IC. GYPSUM SUSP. 5.4 V. HARDWARE HANDICAP HARDWOOD HOSE BIBS HOLLOW CORE HOLLOW METAL HORIZONTAL HOUR HEIGHT INSTALLATION INSULATION INTERIOR LAMINATED POUND LOCATION MATERIAL MAXIMUM MANUFACTURER MANHOLE MECHANICAL MINIMUM MISCELLANEOUS MOUNTED METAL NORTH NOT IN CONTRACT NUMBER NOT TO SCALE SVC. SYM. S/UJ T. T.C. TEL. T.4 G. THK T.0.P. T.P. T.UJ. TYP. U.B .C. UHF. U.ON. VERT. W. w/ WD. wPW. w/0 W.P. W.R WSCT. WT. ON CENTER OVER OPPOSITE PLATE PLYWOOD POWER POLE PLASTIC LAMINATE RADIUS OR RISER ROOF DRAIN RECOMMENDED REFERENCE REINFORCED REQUIRED ROOM SOUTH SOLID CORE SCHEDULE SHEET 5HEATHING SIMILAR SPECIFICATIONS SQUARE STANDARD STEEL STORAGE STRUCTURAL SUSPENDED STAIN AND VARNISH SERVICE SYMMETRICAL SIDEWALK TREAD TOP OF CURB TELEPHONE TONGUE AND GROOVE THICK TOP OF PLATE TOP OF PAVEMENT TOP OF WALL TYPICAL UNIFORM BUILDING CODE UNFINISHED UNLESS OTHERWISE NOTED VERTICAL WEST WITH WOOD WINDOW WITHOUT WATERPROOF WATER RESISTANT WAINSCOT WEIGHT T:TLE INDEX ARCS- IITECTURAL T -0.1 COVER SHEET T -1.1 SITE PLAN - FOR REFERENCE ONLY T -2.1 DEMO AND PROPOSED FLOOR PLAN A JATA SITE DATA JURISDICTION: ZONE: PARCEL AREA: TAX PARCEL NO.: BUILD ING DATA CITY OF TUKWILA TUC 5.66 ACRES 2623049064 Date: j CONSTRUCTION TYPE: TUC PROPOSED AREA: 1,018 SF OCCUPANCY AND OCCUPANCY LOAD TO BE DETERMINED AT THE TIME OF TENANT IMPROVEMENT. F U copy Permit No. V' "� ( x Plar review approval is subject to error and omission', Approval of construction documents does not authoriz the violation of any a •ted code or anco. Recoil• of approve a ' - C. y an • , c - acknowledge f , City of Tukwila BUILDING DIViS!CN NOTE: PER TBL 1015.1 IN THE I15C, ONE EXIT IS REQUIRED (OCCUPANCY LOAD IS LESS THAN 50). LEG ° L DESCR:PrON THAT PORTION OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SECTION 2C TOWNSHIP 23 NORTH, RANGE 4 EAST, OF THE WILLIAMETTE MERIDIAN: IN KING COUNTY, WASHINGTON. COMMENCING AT THE SOUTHWEST CORNER OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER OF SAID SECTION 26: THENCE NORTH 01' 10'24" EAST, ALONG SAID WEST LINE OF SAID SOUTHWEST QUARTER 1 ,293.51 FEET TO THE SOUTH MARGIN OF STRANDER BOULEVARD: THENCE SOUTH 88' 15' 33" EAST, ALONG SAID MARGIN, 665.00 FEET TO THE TRUE POINT OF BEGINNING OF THIS DESCRIPTION. THENCE SOUTH 01 44'21" WEST, 63.00 FEETTO A POINT OF TANGENT CURVATURE CONCAVE TO THE NORTHEAST HAYING A RADIUS OF 130140 FEET: THENCE SOUTH 88' 15'33" EAST, 212.11 FEET THENCE SOUTH 01' 44'21" WEST, 62 .00 FEET THENCE SOUTH 88' 15'33" EAST, 9140 FEET THENCE SOUTH 01' 44'21" WEST, 62.00 FEET THENCE NORTH 88' 15'33" WEST, 133.00 FEET THENCE SOUTH 01' 44'21" WEST, 150.00 FEET THENCE SOUTH 88' 15'33" EAST, 29982 FEET THENCE SOUTH 34' 33'18" EAST, 204.52 FEET THENCE SOUTH 88' 15'33" EAST, 116.14 FEET TO THE WEST MARGIN OF ANDOVER PARK WEST: THENCE NORTH 01' 03'25" EAST ALONG SAID WEST MARGIN 515.42 FEET TO THE SOUTH MARGIN OF STRANDER BOULEVARD: THENCE NORTH 88' I5'34" WEST ALONG SAID SOUTH MARGIN, 64113 FEET TO THE TRUE POINT OF BEGINNING AND TERMINUS OF THIS LEGAL DESCRIPTION. TOGETHER WITH AND SUBJECT TO AN OPERATION AND EASEMENT AGREEMENT BETWEEN DAYTON HUDSON CORPORATION AND S- H- BENOLIEL- ROMNEY •119, RECORDED AT KING COUNTY UNDER FILE NUMBER 8902211002, AND ANY EASEMENTS AND RESERVATIONS OF RECORD. i, , REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED CITY OF TUKWILA JUL 1 2008 PERMIT CENTER V:CHNETY MAP INCOMPLETE VICINITY MAP LTR# NOT TO SCALE r � 0 a 0 CDA P 1 RSCHER ARCHITECTS ODA + Pirscher Architects 1q500 Ballinger Way NE, Suite 200 Seattle, Washington 98155 (206)368 - Fax (206)368 -61558 N L I G I .L .1. al*Va e0 /LO /1-O DRAWN: JZ CHECK: GP JOB NO: 8O2O (IN SITE PLAN z7 NOT TO 5C4LE ST AND FOR REFERENCE ONLY EQL-L VAD R V b/V W "WR CODE COMPLIANCE APPROVED AUG 1 8 2008 City Of Tukwila BIJILDIN_ DIVISION W _ RECEIVED CITY OF TUKWILA JUL 15 2008 PERMIT CENTER !fig 3Cob CDA PIRSCHER ARCHITECTS GDA + Pirscher Architects 14500 Ballinger Way NE, Suite 200 Beattie, Washington 48155 (206)368 -4668 Fax (206)368 -4558 SHEET: T LI OF: SHEETS SIGN 1 SIGN 2 SIGN 3 SIGN 4 ALL LOCATIONS WHERE FIRE EXTINGUISHERS ARE PROVIDED WHITE SYMBOL 3 " =1' -0" 8210.011 3 " =1' -0" 8210.03310 TYP. \\ �' FIRE EXTINGUISHER BLUE BACKGROUND TYP. SIGN TYPE go/1.°A.° WOMEN .. .. ... .... ...... • '..'. '. "..' • • '. AND BRA I LLE TYP. BLACK MEN SIGN TYPE PICTOGRAPH SIGN LOCATION BACKGROUND TYP. •• • •. .... ...... • '. ��..� '. SIGN TYPE SIGN TYPE LOCATION 5 SIGN MATERIAL PICTOGRAPH SIGN MATERIAL VISUAL BRAILLE PICTOGRAPH SIGN MATERIAL VISUAL BRAILLE PICTOGRAPH SIGN MATERIAL ACRYLIC PLASTIC ACRYLIC PLASTIC ACRYLI PLASTIC ACRYLIC PLASTIC NO 11d Ia',G .mss ii wd WOOD DOOR HEAD ( 2 Woo DOOR SILL 3 " =1' -0" 8210.011 3 " =1' -0" 8210.03310 go/1.°A.° ��Vw PRAWN: JZ GHEGK: CP JOB NO: 8020 r 1 - WOOD DOOR HEAD ( 2 Woo DOOR SILL 3 " =1' -0" 8210.011 3 " =1' -0" 8210.03310 1. E ELEVATION PAPER TOWEL DISPENSER 3' WIDE DOOR WITH LEVER HANDLE AT 36 " -42 ", TYP. PLAN SCALE: 1/4"=V-0" SIZE/TI -IK 3' -0" X I' -0" 3' -0" X 1' -0" DOOR TYPES FIN. FLR P -LAM OR APPROVED WAINSCOT 0 1-- A FLUSH CONTROL TO BE ON OPEN SIDE OF TANK, NOT MORE THAN 44" AFF. TOILET PAPER DISPENSER TOILET PAPER 42" GRAB DISPENSER TYP BAR FLOORING TO COME UP 6" ONTO WALL - FLOORING TO BE DETERMINED • TIME OF T.I. RESTROOM PLAN WOOD NOTE: ALL DOORS TO BE HANDICAP ACCESSIBLE. A. FLUSH WOOD O d) 0 a1 PAINT dl 36" GRAB BAR N 12" MAX. 4' -6" 40" 4)-t4) r- -0 !n DOOR MARK DOOR SCkEULE GENERAL NOTES VINYL WOOD DOOR NOTES F.F. PAINT 0 T -2.1 LIGHT FIXTURE TO BE DETERMINED AT TIME OF T.I. 3/4" PLYWOOD SHEATHING BEHIND GIU.B. THIS WALL ONLY INSULATE EXPOSED SUPPY AND DRAIN LINES. INSTANTANEOUS WATER HEATER DETAIL Ea T -2.1 d) 2 T -2.1 FF = FACTORY FINISH SA/ = STAIN 4 VANISH Six.: SEMI -GLOSS ANOD= FACTORY ANODIZED ALUMINUM LAM= LAMINATE REMARKS EXISTING 3,4,6,11,21,23 ,24 IN A GROUP A OCCUPANCY HAVING AN OCCUPANT LOAD OF 300 OR LESS, GROUPS B, F, M AND 6, MD IN CHURCHES, ONLY ONE, MAIN EXTERIOR DOOR (OR ONE, MAN, EXTERIOR PAIR -OF- DOORS) MAY UTILIZE 2006 IBC 1006.1.83 ITEM 2 WHICH STATES • "THE LOCKING DEVICE SHALL BE READILY DISTINGUISHABLE AS LOCKED," • A READILY VISIBLE DURABLE SIGN SHALL BE POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHIM BUILDING IS OCCUPIED THE SIGN SHALL BE IN LETTERS 1 INCH 141614 ON A CONTRASTING BACKGROUND. 2. DOOR SURFACE WITHIN 10 INCHES OF THE FLOOR, MEASURED VERTICALLY SHALL BE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR PARTS CREATING HORIZONTAL OR VERTICAL JOINTS IN SUCH SURFACE SHALL BE WITHIN I/5" OF THE SAME PLANE AS THE OTHER. 3. PAIR -OF -DOORS HARDWARE: MANUAL OPERATED FLUSH BOLTS NOT PERMITTED. APROVED AUTOMATIC FLUSH BOLTS TO EE USED AND NO DOORKNOB OR SURFACE- MOUNTED HARDWARE FOR TI- E DOOR LEAF HAYING THE AUTOMATIC FLUSH BOLTS. 4. THRESHOLDS AT DOORWAYS: IF PROVIDED THRESHOLDS AT DOORWAYS SHALL 8E I" INCH MAXIMUM IN HEIGHT. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 302 AND 303. 5. HARDWARE HEIGHT: HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATION DEVICES SHALL BE INSTALLED 34 INCI-ES MIN. AND 2S INCHES MAX ABOVE THE FLOOR 6. DOOR HARDWARE CONFIGURATION: HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT 16 EASY TO GRASP WITH ONE WAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. 1. DOOR OPENING / CLOSING FORCE: THE OPENING FORCE FOR INTERIOR SIDE- SWINGING DOORS, WITHOUT CLOSETS SHALL NOT EXCEED A 5 -POUND FORCE. FOR OTHER SIDE - SWINGING, SLIDING, AND FOLDING DOORS, THE DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15 -POUND FORCE. THE DOOR SHALL BE SET N MOTION WHEN SUBJECTED TO A 30 -POUND FORCE. THE DOOR SHALL SWING TO A FULL -OPEN POSITION WHEN SUBJECTED TO A 15 -POUND FORCE. FORCES SHALL BE APPLIED TO THE LATCH SIDE. WITHIN AN ACCESSIBLE ROUTE, AT EXTERIOR DOORS WHERE ENVIRONMENTAL CONDITIONS REQUIRE A CLOSING PRESSURE GRATER THAN 85 POUNDS, POWER OPERATED DOORS SHALL EE USED WITHN THE ACCESSIBLE ROUTE OF TRAVEL. 8. SPEED OF DOOR WITH CLOSER DOOR CLOSURES SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MNITIIM. 9. SPEED OF DOOR WITH SPRING HINGE& DOOR SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 10 DEGREES, THE DOOR SHALL MOVE TO THE CLOSED POSITION N 15 SECONDS MINIMUM. 10. A TACTILE SIGN STATING EXIT AND COMPLYIN GIWTH ICC A111.1 SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN EGRESS STAIRWAY, AND EXIT PASSAGEWAY AND THE EXIT DISCHARGE. 0 MIRROR 1. TOILET ROOM PLAN AND ELEVATIONS ILLUSTRATED ABOVE, ILLUSTRATE FIXTURE CLEARANCE DIMENSIONS, MOUNTING HEIGHTS, AND ACCESSORY PLACEMENT. ACTUAL LAYOUT MAY VARY, SEE FLOOR PLAN FOR CORRECT LAYOUT. 2. LOWER EDGES OF LAVATORY NOT TO EXCEED 2' -5" FROM FINISH FLOOR. 3. MIRROR MINIMUM 4' -6 ", MAXIMUM 3' -4" ABOVE FINISH FLOOR. 4. GRAB BARS 1 1/4" - 1 1/2" MOUNTED 1 1/2" FROM WALL. BARS 51-1ALL BE CAPABLE OF SUPPORTING 300 LBS. LIVE LOAD WITHOUT PERMANENT DEFLECTION. 5. LAVATORY RIM HEIGHT 33 " -34" ABOVE FINISH FLOOR. 6. LAVATORY TO NAVE LEVER HANDLE LOCATED NO MORE THAN 11" FROM FRONT EDGE OF LAVATORY. 1. FLOORS SHALL BE SMOOTH, HARD, NON - ABSORBENT SURFACE. FLOORING TO BE DETERMINED AT TIME OF T.I. 8. DIMENSIONS, NOTES, AND EQUIPMENT TYPICAL FOR ALL TOILET ROOMS UNLESS OTHERWISE NOTED. 9. TOILET PAPER DISPENSERS SHALL BE LOCATED 1 " MINIMUM AND 9" MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER THE OUTLET OF THE DISPENSER SHALL BE 15" MINIMUM AND 48" MAXIMUM ABOVE THE FLOOR, AND SHALL NOT BE LOCATED BEHIND THE GRAB BARS. DISPENSERS SHALL NOT BE OF A TYPE THAT CONTROL DELIVERY, OR THAT DO NOT ,ALLOW CONTINUOUS PAPER FLOW 10. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. 11. GYPSUM BOARD APPLIED TO PLUMBING WALLS SHALL BE WATER - RESISTANT. 12. TOILET FLUSH VALVE TO BE ON OPEN SIDE OF TANK 13. PROVIDE BLOCKING AS REQUIRED TO SUPPORT ALL FIXTURES, FURNISHINGS AND EQUIPMENT INDICATED. REMA GENERAL D EMOL ITION NOTES; WHEN PATCHING TO MATCH EXISTING ADJACENT SURFACES AFTER REMOVAL OF ARCHITECTURAL, MECHANICAL, ELECTRICAL OR STRUCTIRAL ITEMS, PATCHING SHALL BE DONE WITH FULL PIECES OF SURFACING MATERIAL TO GET A UNIFORM APPEARANCE. PROTECT ADJOINING BUILDING SPACES FROM DUST, NOISE, ETC. DURING ALL PHASES OF CONSTRUCTION. REMOVE WALLS AS SHOWN. PATCH FLOOR. PATCH AND PAINT ADJACENT SURFACES, PATCH WALLS AND CEILING. PRIOR TO DEMOLITION, VERIFY THAT ALL ACTIVE MECHANICAL, ELECTRICAL AND TELEPHONE SERVICES CAN BE TURNED OFF WITHOUT DISRUPTING OTHER ADJACENT AREAS OF THE BUILDING. CAREFULLY REMOVE AND STORE ITEMS TO BE RELOCATED FOR REINSTALLATION IN NEW CONSTRUCTION. VERIFY RELOCATION OR TERMINATION OF SERVICES IN ALL WALLS TO BE REMOVED, COORDINATE WITH ELECTRICAL AND MECHANICAL, TRADES PRIOR TO DEMOLITION. PROTECT AGAINST DAMAGE ANY ITEMS TO REMAIN. SALVAGE AND STORE ALL USABLE ITEMS PER OWNERS REQUEST FOR FUTURE USE. PATCH WALLS AND FLOOR AFTER REMOVAL OF ARCHITECTURAL, MECHANICAL AND ELECTRICAL ITEMS. CAP WASTE, VENT AND WATER LINES IN WALLS OR BELOW FLOOR WHERE PLUMBING FIXTURES ARE BEING REMOVED. KEY NOTES; l!J RKS: REMOVE EXISTING WALL. REMOVE EXISTING DOOR AND DOOR FRAME. REMOVE ALL EXISTING FLOOR MATERIAL. PREP SURFACE FOR FUTURE TENANT. PREP ANY EXISTING DRYWALL, TO REMAIN, FOR FUTURE TENANT. REMOVE EXISTING RUBBER BASE. REMOVE EXISTING DROP CEILING, LIGHTING FIXTURES AND VENT COVERS. REPLACE EXISTIG ELECTRICAL PANEL WITH A NEW 200 AMP PANEL. EXISTING ELECTRICAL OUTLETS AND PHONE JACKS TO BE ABANDONED. U EXISTING DOORS TO REMAIN. 00 1. PROVIDE DECAL SIGN WITH 1" WHITE LETTERS ON CLEAR BACKGROUND READING: THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS'. LOCATE ON TI-IE INSIDE OF TRANSOM. 2. SELF CLOSING WITH CONCEALED CLOSURE. 3. PROVIDE AND INSTALL 6" SQUARE INTERNATIONAL SYMBOL OF ACCESS SIGN. THE SIGN SHALL BE ALONGSIDE THE DOOR AT THE LATCH SIDE. TACTILE CHARACTERS SHALL BE 48" MIN. ABOVE THE FLOOR MEASURED TO THE BASELINE OF THE LOWEST TACTILE CHARACTER AND 60" MAX ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST TACTILE CHARACTER PER ICC /ANSI A111.1 -2003 SECTION 1033.10 4. SOLID CORE. 5. PROVIDE DEAD BOLT WITH THUMB TURN. 6. PROVIDE LEVER HANDLES ON ALL MAN DOORS (EXCEPT STOREFRONT). 1. U VALUE MAX = 020 FOR SYSTEM TESTED AS UNIT ASSEMBLY (SOLID DOORS). S. PROVIDE PUSH BUTTON LOCK 9. SELF CLOSING WITH CLOSER 10. LOCK FUNCTION. II. ORBIT HANDLE. 12. CHAIN STOP WITH HOLD OPEN. 13. PASSAGE LATCH. 14. PUSH PLATE. 15. SELF CLOSING. 16. HOLD OPEN. 11. PRIVACY LATCH. 18. GASKETING. 19. FLUSH PULLS. 20. LATCH GUARD. 21 DOOR STOP. 22. CI4AIN I-IOIST 23. PROVIDE SIGNAGE PER CODE. 24. PROVIDE SIGNAGE INDICATING ROOM USE. INTERIOR SICN CHART 0 9 SCALE: 1/4" = 1' -0" EXISTING WALL WALL TO BE DEMOL ISHED NEW WALL egg DEMO 4 E>dSTNC FLOOR PLAN PROPOSED FLOOR PLAN SCALE: I/4•• , I' -0• WALL INDEX: 52' -0" JAMB SIMILAR 1/2" UV TRIM WOOD DOOR 4 FRAME PER SCHEDULE 3' -9" 4' -5" COD- COMPLIANCE SCE PROVO 1 8 2000 City 0fTu .0 DINT; Dr 7C .. NEW 200 AMP ELECTRICAL PANEL 8' -6" SEWER LINE TO BE STUBBED OUT AND CAPPED FOR FUTURE TENANT. LNE TO BE CONNECTED TO EXISTING SEWER WOOD DOOR PER SCHEDULE WOOD FRAME o WALL TYPES SCALE: 1- 1/2 =1' -0" SOUND ATTENUATION BLANKET R -11 (IN RESTROOMS) 5/8" TYPE "X" GJUJ3. 4" 20g8 METAL STUDS s 24" O.C. SAME AS WALL TYPE "A" EXCEPT 6" STUD INSTEAD OF 4" STUD. NOTES: 1 ALL FRAMING MEMBERS SHALL BE AS MANUFACTURED BY THE MILCOR DIVISION OF INRYCO, OR APPROVED EQUAL, AND SHALL BE OF THE TYPE AND SIZE AS SNOUJN ON NE DRAWINGS. 2. ALL GALVANIZED 20 GAUGE STUDS, AND ALL GALVANIZED TRACK, BRIDGING, END CLOSURES AND ACCESSORIES SHALL BE FORMED FROM STEEL THAT CORRESPONDS TO THE REQUIREMENTS OF A.5TM. A -446, GRADE "A" WITH A MINIMUM YIELD OF 33 ,000 P.S.I. 3. ALL GALVANIZED STUDS AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G -60 GALVANIZED COATING. 4. FASTEN PARTITION WALLS TO FLOOR WITH 3" EXPANSION BOLTS WITH WASHER • 24" O.C. 5. WALL FINISH TO BE GIU.B. TAPED, TEXTURED, PRIMED AND PAINTED. RECEIVED CITY OF TUKWILA JUL 1 2008 PERMIT CENTER FLOOR COVERING FLOOR COVERING RK O z O O LL W L CDA P 1 RSCHER ARCHITECTS GDA + Plrscher Architects 19500 Ballinger Way NE, Suite 200 Seattle, Ytiashington 98155 (206)368 -9665 Fax (206)368 -9558 SHEET: OF : SHEETS poOF .3&142 PROPOSED 1-IR RATING