Loading...
HomeMy WebLinkAboutPermit D08-374 - OLANDRES RESIDENCE - ADDITIONOLANDRES RESI 1 ENCE 14257 MACADAM RD S D08 -374 Parcel No.: 1523049171 Address: 14257 MACADAM RD S TUICW Suite No: Tenant: Name: OLANDRES ADDITION Address: 14257 MACADAM RD S , TUKWILA WA Owner: Name: OLANDRES PERFECTO B +ELSA Address: 14257 MACADAM RD S , TUI{1NILA WA 98168 Phone: Contact Person: Name: PERFECTO OLANDRES Address: 14257 MACADAM RD S , TUKWILA WA 98168 Phone: 360 990 -0199 doc: IBC -10/06 Citylef Tukwila M Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contractor: Name: OWNER AFFIDAVIT - PERFECTO B OLANDRES Address: Phone: Contractor License No: DEVELOPMENT PERMIT Permit Number: D08 - 374 Issue Date: 08/25/2008 Permit Expires On: 02/21/2009 Value of Construction: $27,167.14 Fees Collected: $897.15 Type of Fire Protection: NONE International Building Code Edition: 2006 Type of Construction: VB Occupancy per IBC: 22 Expiration Date: DESCRIPTION OF WORK: SECOND FLOOR ADDITION. REMOVE EXISTING OLD ROOF, ATTIC, AND WALLS. INSTALL NEW ROOF WITH 4:12 PITCH, NEW INSULATION, WALLS, JOIST, RAFTERS, WINDOWS, DOOR, ACCESS STAIRS, AND LIGHTS. * *continued on next page ** D08 -374 Printed: 08-25 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Permit Center Authorized Signature: Print Name: doc: IBC -10/06 Pt City oinukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Water Main Extension: Water Meter: N I hereby certify that I have read and x governing this work will be complie wi FE ci o O L 4- AJDTZES Permit Number: D08 - 374 Issue Date: 08/25/2008 Permit Expires On: 02/21/2009 Number: 0 Size (Inches): 0 Start Time: End Time: Volumes: Cut 0 c.y. Fill 0 c.y. Start Time: End Time: Private: Public: Profit: N Non - Profit: N Private: Public: Date: O 1 "∎ 1 ed this permit and know the same to be true and correct. All provisions of law and ordinances h, whether specified herein or not. The granting of this permit does no • resume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performan - of work. I am authorized to sign and obtain this development permit. Signature: ••: � Date: c V g This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -374 Printed: 08 -25 -2008 Parcel No.: 1523049171 Address: Suite No: Tenant: doc: Cond -10/06 14257 MACADAM RD S TUKW OLANDRES ADDITION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 7: All wood to remain in placed concrete shall be treated wood. 13: ** *FIRE DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -374 ISSUED 07/15/2008 08/25/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: Adequate ground ladder access to rescue windows shall be provided. Landscape a flat, 12' deep by 4' wide area below D08 -374 Printed: 08 -25 -2008 each required rescue window. • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 16: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D08 -374 Printed: 08 -25 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -10/06 Date: g/2-rio8 D08 -374 Printed: 08 -25 -2008 Site Address: Property Owners Name: PEg 5c () /J41= 9 Tenant Name: Mailing Address: (4 v C Amt 79Kto Name: Mailing Address: E -Mail Address: Company Name: Mailing Address: Contact Person: PE PF - C- i�O I.J D E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 42 1 U,4-C,4 -pA R 2 PE R E c o O 1-1 S coo F Q:\Applications\Forms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh Building Permit No. Mechanical Permit No. Public Works Permit No. Project No. Plumbing /Gas Permit No. King Co Assessor's Tax No.: Suite Number: New Tenant: (For office use only) IG1 —°1111 Floor: ❑ .... Yes ❑ ..No City State Zip on et CONTACT PERSON iben your permit i dy to be issued Day Telephone: 56Q-9RO Q 1 U <t4,1L»e City J�, State tp F lv 4 �l_ yadrb, (,3t Fax Number: GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4): for Plumbing and Gas Piping (pg 5)) City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF Rl All plans must et stamped by!Archifec o Record Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip INEER OF REC Al[ plan taped" by Eng City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORM " rION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ ,6 -- 7© 1) Existing Building Valuation: $ Scope of Work (please provide detailed information): 2A.I ''161),ka / 7 R EMOV Q1--D POOF, 1-!7 714. k)A2.L , I STA1:;__. ,fit = . d (� IC k)/7+ 4.'/2 P l TC N cc1 /41 5 U L A ' �IA) .. � 9 Gc)11)Dr'` ;Dory= ,+CcE, C 7 1F,.._. 1 !,�' /6 -A' Will there be new rack storage? E.... Yes Number of Parking Stalls Provided: Standard: Q:\Applications\Forms- Applications On Line\3.2006 - Permit Application.doc Revised: 9 -2006 bh o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below l Floor 3t Floor Floors " thru Basement Accessory. Structure* A ed Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck Addition -to Existing Structure Type of struction per IBC Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area ft : ' principal dwelling: z (s 9 ) Floor area of p p g: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm r' None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ;j No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Date Application Accepted: 1 (� I A Date Application Expires: ��Y 6 Staff Initials: ro I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER R A HORIZED AGENT: Signature: Print Name: fZFe arm ©L,f04 DR.E-S Mailing Address: /4 2 $7 M eA birt -t S Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh 7 /LA City Date: Day Telephone: 360 99O-69)99 State Zip Page 6 of 6 ` �, Fixture Type: Qty Fixture Type: Fixture Type: Qty . Fxture, Type: Qty Bathtub or combination bath /shower Drinking fountain o ater cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste gri er, commercial R ptor, indirect was Clothes washer, domestic Floor drai Sinks Dental unit, cuspidor Shower, gle head trap Urinals Dishwasher, domestic, with independent drain Lavato Water Cl Building sewer or trailer park sewer R ' water system — per in (inside building) Water heater d /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors epair or alteration of water piping and /or water treating equipment Repair or alterati of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING 1 RMIT INFORMATION — 206- 431 -Jo70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Nu ber: Valuation of Plumbing work (cont ctor's bid price): $ Valuation of Gas Piping work (contra or's bid price): $ Scope of Work (please provide detailed ' formation): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outl Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh bei installed and the quantity below: City State Zip Day Telephone: Fax Number: Expiration Date: Page 5 of 6 Parcel No.: 1523049171 Address: 14257 MACADAM RD S TUI{W Suite No: Applicant: OLANDRES ADDITION Receipt No.: R08 -03044 Initials: JEM Payment Date: 08/25/2008 11:22 AM User ID: 1165 Balance: $0.00 Payee: PERFECTO OLANDRES TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 537.15 ACCOUNT ITEM LIST: Description BUILDING - RES STATE BUILDING SURCHARGE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/386.904 RECEIPT 532.65 4.50 Total: $537.15 • Permit Number: D08 - 374 Status: APPROVED Applied Date: 07/15/2008 Issue Date: Payment Amount: $537.15 doc: Receipt -06 Printed: 08 -25 -2008 Parcel No.: 1523049171 Address: 14257 MACADAM RD S TUI{W Suite No: Applicant: OLANDRES ADDITION Receipt No.: R08 -02566 Payee: PERFECTO OLANDRES BUILDING - RES PLAN CHECK - RES • City of Tukwila ACCOUNT ITEM LIST: Description Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 360.00 RECEIPT Account Code Current Pmts 000/322.100 8.35 000/345.830 351.65 Total: $360.00 Permit Number: D08 -374 Status: PENDING Applied Date: 07/15/2008 Issue Date: Payment Amount: $360.00 Initials: JEM Payment Date: 07/15/2008 09:52 AM User ID: 1165 Balance: $537.15 4834 07/15 9711 TOTAL 360.00 doc: Receiot -06 Printed: 07 -15 -2008 COMMENTS: pe_r m: /,,f0 kA . ,t. Address: l LI 2-57 [(el Pre A bA Date Called: P-0 4 D 0 Nio 05c_ 1-0 k e�P i 6 1-- '`tA( Oc u�c1 rrSS 1A.�; l,Js o0 Aj r L &i t\ AAS A) 00 � T ,/.." r Requester: n y __ r � �l 1 A r Project: Type of Inspection: Address: l LI 2-57 [(el Pre A bA Date Called: P-0 Special Instructions: V Date Wanted: — q --OCI p.m. Requester: Phone No: 3AO n — o icrc i INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. D Corrections required prior to approval. Inspec 6r: �R �{ Date: , v El $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reispection. Receipt No.: 'Date: /I 19 COMMENTS: Type of Inspection: C /24M /F4, 4 ; 1; re nom � r - „ - ”" Address: /4'257 /lAw9t.» l Date Called: Ge (1' ,- 1 10( -- TIN, M n ) A 5LM( MDT be vS (- 1 1 ;u . /-4fA. ,o/e LT 1)-i _ i ji11401,i SI Ili ' ; s o Vr (, 1L X 1 A Ik€ (/\ 1 d/ 6\-16 A. T 2--t ` s) S , . 1 -; I f .i1.I ( Nl IQ v C- -; R.e.. C., f\ J n i.N A" 5 r ls -44O9 `i` c_n 0\4 I (- i . . (it A ,p,.A_A Project: p[�,�/v 4Jvrnon/ Type of Inspection: C /24M /F4, ibZ j Address: /4'257 /lAw9t.» l Date Called: Ge (1' ,- . • Special Instructions: Date Wante /: /4 /0 7 Requester: Phone No 6 9V- 6 (L- Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Da--37 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ons Gir io r b appro I. Inspector: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 3 _ � . (I) �j l Receipt No.: 'Date: Project: 4.Zip NraelSS 12 )/7frn/ Type of Inspec 'on N 4 e e /' , ' Address: /5/257 mi 14 V) Date Called: .S ' Special Instructions: _Ne (t_b Date Wanted: a.m. ,,,2 — 5-05 cps: Requester: Phone No: „...,.., , ,,,, t c5 ,�34'U INSPECTION RECORD Retain a copy with permit INSPECTION NO PERMI NO. CITY OF • UKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 jDate: 2 4• -5 -� ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: codes. "OA ctions required prior to approval. Aoilirr A roved per applicable ENTS: _Ne (t_b (, e 2k, Pt, - T.NeLs. A .1 4 ( e.....c. -P CT, 1 ()F- J r lid: A ..,0 ..,(' P. If . -- � Ji ;r r C - A ea IWIS ,-) - , mss INSPECTION RECORD Retain a copy with permit INSPECTION NO PERMI NO. CITY OF • UKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 jDate: 2 4• -5 -� ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: /On/ F(24f 7/N( - ( deer -~t --� �e7 e -+ - t `o 44-AA.J e .P*T'V ` !v r f 4 t (. A p.m. Requester: l 7 - a /9' v l (4I /400 , -) s . 9 Project: OZ AAJ A'S '9i) Type of Inspection: /On/ F(24f 7/N( Address: 7 Date Called: Special Instructions: Date Wanted: /— / Z — a p.m. Requester: Phone No: _3 G 4,-- 9 5`0 - a /9' INSPECTION RECORD ` Retain a copy with permit DM : 3 7z/1 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 t (206)431 - 3670 ❑ Approved per applicable codes. Corrections required prior to approval. Date: V r 7 —`'4 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: i, r I � Al t kl AB�.I �f w sa : - — Type of Inspection: �/204n //1/zi oAC.. s� e . 1)A w.� iR �r s dared( ems — ACT _ 34J' ,AA 'P\ T) 3k '` _' Address: �4'z. AJj..j 7 l'•/I _ ,'AJv (4'1 \ 1 1 4 Date e- C �' I, (/ -41 D I h l-ef — LA Ff4 : «.r fled. ^J - ..* , •\_cf).P../± -- 4 -- - -, I a.m. Requester: A Project: ()LA,VL ( 42) / Type of Inspection: �/204n //1/zi Address: �4'z. v 4g� M Date e- C �' I, . Special Instructions: Date Wanted: a.m. Requester: Phone No: 4 INSPECTION RECORD Retain a copy with permit £ 37q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. El Approved per applicable codes. Corrections required prior to approval. InspQEtor: T1 Date: 4 • El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: / / � - "G / /ix, t��O/ / // Cr !I, .�/!�'v/ // /U` S(9 e" / H 5 die? / / 1 ,m.�1 4/ / // / / 4 / Lv -.pvw .L /L. /• i...-:,./ 0.---- ,I /7�. ---- ,fro, I. Aig7/1• 1 t kr, / o G. /• /Ni 7 /7r1 G V/ - ,4 ir4 / G /�c Special Instructions: Date Wanted: /2 _ „v- p1-- p.m. Requester: Phone No: 36 o >9O -0/9 9 Project: / - Apr 'i ili '(v4.- Type of Inspection: . 4/6)°7 TT. 04 61,,, < r". Address: / /9 7 /lac 4 Date Called: Special Instructions: Date Wanted: /2 _ „v- p1-- p.m. Requester: Phone No: 36 o >9O -0/9 9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431-3670 ❑ Approved per applicable codes. Corrections required prior to approval. Date: $58.00 REI PECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6 00 Southcenter Blvd.. Suite 100.,Call the schedule reinspection. !Receipt No.: 'Date: • 61 4 r 5.' . - u 'it $4404u ttitsAr' • 4.- • w __ '._ 4 �m .� b aa�t 'µ10.24r r- Lt. a..' Project: (Yam/ kw , �- Type of Inspe : ' �2 T(dv Z r ' A g -7 4�� n � Date Called: Special Instructions: Date Wanted: /2' b te —O? p.m. Requester: Phone No: 160 — 97o -- t / l S'- 77y PERMIT NO. CITY OF TUKWILA BUILDING DIVISION fz- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit COMMENTS: Inspector Datej��� a I"pproved per applicable codes. O Corrections required 'prior to approval. El 60.00 REINS A CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 outhcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: /wk /0/1/%00v Type of spection: - 6G —4b/ / ..j N Address: //�� % G � /y?5" 7 /raO" v ti �G -�r Date Called: Special Instructions: • Date Waned: /3 - .7 04.1' p.m. Requester: Phone No: 3 (60 - ? %' -o /97 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval COMMENTS: P, 7 (e) z4e Date: - ��� ri 60.00 REI ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6 I Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • u�= Li COMMENTS: & k (-119 ZlLf U (A — t — L " Add i ,1 ress: ZJ 1 v, rr7 J A e.Ac Q Date Called: 1 eAr & b. )t,-)/\ 'Tv r y rol.,.p , .A - !STA er Requester: Phone 3- (0 6 - 5q Q _ o ( Q J- A .. . - ... - - ' pJf ( t t x )14 �. (.... t 42 -4 r oar c ,.i : P Axe,f5 6 /\ 61/4_ Jt) 0 r 5 - I r i i + -. -- DO f p-1" 1 A S L-e. (\ Di" `c ' S ryk- t t L.: li : A 6 r 6 4 fkoe -' 0:‘ \ 1. e... per Art' Project: O LArkiiiteS Type of Inspection: Add i ,1 ress: ZJ 1 v, rr7 J A e.Ac Q Date Called: Special Instructions: Date Wanted, O - C)y a.m. p.m. Requester: Phone 3- (0 6 - 5q Q _ o ( Q J- i INSPECTION RECORD Retain a copy with permit - PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspector I( . 1 tte, Q 0 Y ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: of Insp tion: R A•�tik.) C� Address: -^� 1 4 ZS / YMA ,J) C.,.c' 4r. c eaP `? t' el , ;r P—or oJeTL .0•s 1 '0 e u J aA. i f. J -- ,ce_c e ' A a-ALA 4 I. r— ; - s c - jr : ,s....--\ . Special Instructions: • 7 , , 7) (& i a L- c \ r c CP ex - re) . i``o i t, i . 1 I n o cA r\ •-•- 0JS l trji L1AJ.� 4 3 G- \ r 1 1 , -- S .PA ( (7 t, . A i .P 4ji c 5 u, 04 t Ain UL: _ _ c_ C A" ,i .S Al L ,J ' ,) k Project: , C)LAN l <c of Insp tion: R A•�tik.) C� Address: -^� 1 4 ZS / YMA Add V1 Date allgd c�t. Special Instructions: • Date Wanted • m- Requester: Phone► c 5 u, 04 4+4 INSPECTION NO. a Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. Inspector (Date: q El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 1;00. Call to schedule reinspection. Receipt No.: !Date: / p Jo( COMMENTS: Type f Inspec 'on: shPa -thiWc. Address: I Li ? 7 r A btlYn Date Called: ,..,. Special Instructions: Date anted: 7 I Done/ s in i-i ( , i L 'i j /ii'J t' I.J ; d P ' en v r,, � G , - y - ( I �o� c - /- A r 6 ( 6 � 1 Project: O(, A lv P R, Type f Inspec 'on: shPa -thiWc. Address: I Li ? 7 r A btlYn Date Called: ,..,. Special Instructions: Date anted: a Requester: Phone No: l INSPECTION RECORD Retain a copy with permit . D08-374 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. Inspector Date: 9 _ 69 _ J � $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: I naivr a _ _ - - -"°" voss�n '�` .�`� =�- - -• " .e.� km.1,a --- __ COMMENTS: 1.1 ( .S G.e It, ,r1 A epl, ✓ i ‘f . - luo r'f- : ,Jb' e r/ { di - ,'A,.p .' �l, otJn eI 51 i( !P - w -la %-fjjJ4 S 0 72. , - t 73. P • / 4 t: r� Av f v1 "I X(.9 / (') r , ? 0 ��` /�_"( S - 4 0 A./a7 h d( A: • -)1 jr i J1-( 2 X(o I t 4-l J �— f v r' ,J/!7 ( iG Z,!r• �' AC't) T L,-- Vn -P'�c ST :. ' I A 'J A- 3 �( `� Tiv; S f h-LL r 3/\ c,-/ti/,d r b e vSf J Ai 44 . 6+'1* Proje t: L I 1 Y 1 � S Type of Inspection: LA A S. hP AV) iA6 /s t'V Address: 4 Th ; C mAP WI Date Called: Special Instructions: Date Wanted: a:m"' C _- 1 t- Oe p.m. Requester: Phone No: 1 INSPECTION NO. I INSPECTION RECORD Retain a copy with permit i °v 3 L( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 pproved per applicable codes. EI Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Ait IDate _ , th Project: _�, f )' A,tSt1's .L / / 7` Type of Inspection: 0 , t i 9dI efh4 ess / 112 s .2 /774-1 - Date Called: Special Instructions: Air Date Wanted: 9 /..5 oS Requester: - g Phone 60 0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING /DIVISION 06300 Southcenter Blvd., #100, Tukwila, WA 98188 E RMrT NO. (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. /Z COMMENTS: 41 ,) &< Inspecto EINSPECTION FEE ` EQUIRED ' rior to inspection, fee must be 6300 Southcenter Blvd., Suite 1 ' 0. Call to schedule reinspection. Receipt No.: 'Date: Project: 0 L., / iiJ `e J n 1 I' � °� Typa Inspection: JI (i�. e µo,r� MI) V.1 i( Address: n r L`J / l� ��� Date Called: IL - Sp 141_1S - 9 a Instructions: Date Wanted: ` 2 1 1 - , r/ _a m (9- t„n p.m. Requester: Phone 60 5q0 1 9/ D - 3 ? 4 t - INSPECTION RECORD R etain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1, " 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. `COMMENTS: Inspec J\kr (Date: . . U $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: 6 Project: 014 b ier Ad o14-bh Sprinklers: Type of Inspection: Fa h.1 Address: Suite #: J y A444 dm., S Contact Person: Pc feu , CSI 4 . t, ir e ..� Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm:, Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 V Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 co PERMIT' NUMBERS ri Corrections required prior to approval. COMMENTS: Inspector: • Date : _0 9 Hrs.: n $80.00: REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 01 -02 -2009 BRUCE DEES 222 E 26 ST 3202 TACOMA WA 98421 RE: Permit No. D08 -372 14800 STARFIRE WY TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 02/07/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, J nnif r Marshall, Pe Technician xc: Permit File No. D08 -372 City of kwi Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 August 14, 2008 Perfecto Olandres 14257 Macadam Road S Tukwila, WA 98168 • • Ciz of Tukwila Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Application Number D08 -374 Olandres Residence —14257 Macadam Road S Dear Mr. Olandres: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time the Building, Fire, and Public Works Departments have no comments. Planning Department: Stacy MacGregor at 206 433 -7166 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, 1491e Brenda Holt Permit Coordinator encl File No. D08 -374 P:\Pennit Center\Correction Letters \2008\D08 -374 Correction Ur #1 .DOC wer mix Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: APPLICANT: RE: ADDRESS: • August 11, 2008 Perfecto Orlandres D08 -374 14257 Macadam Rd S PLANNING DIVISION COMMENTS Please review the following comments listed below and submit your revisions accordingly. If you have any questions on the requested revision, Stacy MacGregor is the planner assigned to the file and can be reached at 206 - 433 -7166. 1. Rear yard setbacks are 10'. The proposed stair cannot be constructed in the rear yard setback area. July 21, 2008 Perfecto Olandres 14257 Macadam Road S Tukwila, WA 98168 Dear Mr. Olandres, • City of Tukwila RE: Letter of Incomplete Application # 1 Development Permit Application D08 -374 Olandres Residence —14257 Macadam Road S • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 15, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, -63tatip,„ 144.— Brenda Holt Permit Coordinator Enclosures File: D08 -374 P:\Permit Center\lncomplete Letters\2008\DO8 -374 Incomplete Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Determination of Completeness Memo Date: July 17, 2008 Project Name: Olandres Addition Permit #: D08 -374 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Plan provided indicates a construction of a storage room. However the cover sheet shows storage /office. Please be more specific throughout the plan as to the intended use. Be specific about the type of items that shall be stored. The plan shall specify that the room shall not be used as a bedroom or living space. 2. Cover sheet shall specify current code compliance with 2006 IRC, 2006 IBC and 2006 WSEC. 3. Identify existing lower building construction i.e. wall framing, floor construction, size of foundation and provide a floor plan of the existing building as built before the addition of the upper structure. Identify rooms below. 4. Exterior walls are shown as 2x4 framing with R -21 insulation. R -21 insulation for exterior walls shall be placed in 2x6 wall construction. New exterior wall construction for heated spaces shall be constructed of 2x6 framing. Revise plan to show compliance with the current building and energy codes. 5. Provide more specific information or details for the roof construction either identifying the roof system as a manufactured roof or provide and engineered detail for the roof system. 6. Identify mechanical connections and specify nailing pattern for sheathing and framing members including specifications for roof truss mechanical connections. 7. Plan shows 2x6 floor joist spanning 13 feet. Identify grade of lumber and show the joist shall be sufficient for the span and sized for the floors intended use. 8. Provide details for the ledger connections where the floor ledger board connects to the existing house. Ledger shall be attached to a baring wall. Identify all mechanical fasteners and spacing. 9. All exterior walls shall meet wall bracing requirements. The wall with the window adjacent to the door including the opposite side panel next to the other window does not meet the minimum for wall bracing of 32 inches. Please revise drawing to show all wall bracing and connections meet building codes. Identify fasteners and spacing for all framing members and sheathing (IRC Chapter 6 & Table R602.3 [1]). 10. Show how the new wall and roof construction shall connect to the existing building. Provide details. 11. Specify type and size of windows including the exterior door. 12. Provide complete details for the stairway construction identifying dimensions for step and rise including handrail specifications. Show the total run of the stairway. Show a landing at the top and bottom of the steps. 13. Specify if this space shall be heated. Show source of heat. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D08 -374 DATE: 08 -18 -08 PROJECT NAME: OLANDRES RESIDENCE SITE ADDRESS: 14257 MACADAM RD S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works DETERMINAT ON OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 APPROVALS RJR CORRECTIONS: F ire Prevention Structural Incomplete ❑ TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved J Approved with Conditio s Notation: REVIEWER'S INITIALS: C DATE: DATE: 7In �I�b� Planning Division ❑ Permit Coordinator No further Review Required DUE DATE: 08-2 1 -08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 09-18-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -374 DATE: 08 -05 -08 PROJECT NAME: OLANDRES RESIDENCE SITE ADDRESS: 14257 MACADAM RD S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ` �� 1 • ing (vision Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08-07 -08 Complete Comments: Please Route o PERMlT COORD COPY • PLAN REVIEW /ROUTING SLIP Permit Center Use .Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS R UTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Prevention Structural Incomplete Structural Review Required n Planning - D'vision Permit Coordinator Not Applicable No further Review Required DATE: DATE: DUE DATE: 09-04 -08 4 Approved ❑ Approved with Conditions I Not Approved (attach comments) Fr Permit Center Use Only . . CORRECTION LETTER MAILED: 0' 14.0D Departments issued corrections: Bldg ❑ Fire ❑ Ping (� PW ❑ Staff Initials: `PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -374 DATE: 07 -15 -08 PROJECT NAME: OLANDRES ADDITION SITE ADDRESS: 14257 MACADAM RD S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: 11 B g CSTvision LEI 1 1- IAA Public Works p , p Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Comments: Please Route Complete Incomplete Permit Center Use Only ' INCOMPLETE LETTER MAILED: 14 Departments determined incomplete: Bldg TUES/THURS ROUTING: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 Structural Review Required Planning Division C Permit Coordinator LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 07-17-08 Not Applicable n DATE: DATE: No further Review Required n DUE DATE: 08-14-08 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only : CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: r City of Tukwila Sheet Number(s): V PA Eg-J J 2 � � , g 744 "Cloud" or highlight all areas of revision including d ate of revision Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Received at the City of Tukwila Permit Center by: Entered in Permits Plus on b. t \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • REVISION ' SUBMITTAL i Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: A 1,57/ 2 tg Plan Check/Permit Number: D08 -374 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued R [1] Revision requested by a City Building Inspector or Plans Examiner 'O j cD AUG 18 Project Name: OLANDRES RESIDENCE app,, ?119 Project Address: 14257 Macadam Road S Contact Person: Perfecto Olandres Phone Number: 9O"0/9 Summary of Revision: /. gEvlsED /iv,OE)( 7a IORA -0/A$ To R 1= FL EcT R6v /sio TO PRO-7E56 STAY . 2. REVISED PA E _1 � 2 � 3 / G.7 6 Tb sow i(1Gu� ( pe-tA T7t�� OF 116POSEv ,STA -112 PROPOr /AAIDIAIG A lEct3 LO ,4TJOAI blc ,DOOR UDOtoS , ,QELOC, l E- Ll T CIA. / AS Sitawd o/./ )A-t & 3 . City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us i REVISION SUBMITTAL pgr / of3) Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Au6-- , 2.00e) Plan Check/Permit Number: D08 -374 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: OLANDRES RESIDENCE Project Address: 14257 Macadam Road S Received at the City of Tukwila Permit Center by: Entered in Permits Plus on O' /05/0 r \ applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: RECEIVED CITY OFTUKWILA AUG 0 . 5: 200B PERMIT CADITR Contact Person: Perfecto Olandres Phone Number: CJ 60) 4'9 ^ 0199 Summary of Revision: CoRREcTED A- DP /TlbiJ OF S7DRA-4& &ZDOA vAi EA -TAD mor /41TE VEb FOR USE AS LI v /a9G- S f,CE ► EE COVE i2 SI/ 2, C'o0E Con L/thOCb c4.2/7Zt- Zoe 1PC 2006 TEC O 2C04, kJ EC SP /FI ED 8N (vER //-EET , i �X /STl �tl�r Lex0Ele 6 U/Wrlog GE•o$TRocrio4 IS . // J,0 P46,E Ca n P *GE 7. 'I , CORREcTEL O/J PA-GE 9 t 1 ()NH-EA - TEO SP *cE b REVISE. OAJ PACE 9 kiMAMFA-C goof Cm /srR uc,T,Or1 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision 1: • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E - mail: tukplanPci.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ) ss. Owner Signed and sworn to before me this Z'T day of YP Residing at Name as commissioned: My commission expires: Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 - 0 1 79 Planning Division 206 431 -3670 PERMIT NO: P99) J P/ FE c o O , states as follows: [please print] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under No. 12 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have . nder state law in any decision to engage an unregistered contractor to perform construction w BLIC in and for the State of Washington Coun '16 1 9 -� d � 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: i. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; i6. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; . i8. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perforili plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. INDEX TO DRAWING: PAGE 1 - PAGE 2 - PAGE 3 - PAGE 4 - PAGE 5 - PAGE 6- PAGE 7- PAGE 8- PAGE 9- VICINITY MAP AND FLOOR PLAN R EY 3 FRONT AND REAR ELEVATION, REV 3 RIGHT AND LEFT ELEVATION; LIGHTS ELECTRICAL, REV 3 FRAMING AND BRACING DETAILED ATTACHMENT TO EXISTING SFR. AS -BUILT FLOOR PLAN OF EXISTING SFR. Rev 3 EXISTING LOWER BLDG FRAMING & PLAN Ike v3 STAIR DETAIL � REV 3 FOUNDATION AND CROSS SECTION SITE ADDRESS: 14257 MACADAM RD. S. , TUKWILLA, WA 98168 PROJECT DESCRIPTION: 2 FLOOR STORAGE ADDITION. THE EXISTING SFR IS CURRENTLY HAVE A ROOF PITCH OF 8:12 WITH A HEIGHT OF 20' FROM GROUND TO THE RIDGE OF THE ROOF. THE PROPOSED 2 FLOOR STORAGE ADDITION WILL BE ADDED BEHIND THE EXISTING SFR ABOVE THE LAUNDRY/UTILITY ROOM OF 21'W X 13'L SIZE. THIS PROPOSED ADDITION IS UNHEATED AND WILL BE IN ACCORDANCE WITH 2006 IRC, 2006 IBC AND 2006 WSE C I_F_ APPLICABLE THRU THE HELP AND GUIDANCE OF THE DCD BUILDING DEPARTMENT. ITEMS THAT WILL BE STORED IN THIS ADDITION ARE: COLLECTIONS OF SMALL FIGURINES /ANTIQUES; COMMON HOUSE HOLD ITEMS; TOOLS; ETC. THE ADDITION IS NOT INTENDED FOR LIVING SPACE. GENERAL NOTES 1. ALL WORKS SHALL COMPLY WITH IBC, IRC AND WSEC.Et""L2 Dy O 2. THE OWNER IS RESPONSIBLE TO CHECK THE PLANS. 3. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE DRAWINGS. 4. DESIGN LOADS: (LIVE) ROOF 25 PSF; FLOOR 40PSF; STAIR 100PSF. 5. INSULATION: ROOF R -38; EXTERIOR WALL R -15 OR BETTER; FLOOR OVER UNHEATED SPACE 6. THE ABOVE VALUES ARE A MINIMUM AND MAYBE INCREASED IF DESIRED. 7. ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING OF LESS THAN 25 AND SMOKE DENSITY RATING < 4.50. 8. PROVIDE INSULATION BAFFLES AT EAVE VENTS BETWEEN RAFTERS. FRAMING NOTES: 1. ALL EXTERIOR WALL OPENINGS AND BEARING WALL OPENINGS TO HAVE A 4X8 HEADERS UNLESS OTHERWISE INDICATED._ 2. JOISTS THAT ARE ATTACHED TO FLUSH BEAMS ARE TO BE HUNG WITH SIMPSON U -210 OR EQUIVALENT. 3. PROVIDE DOUBLE JOISTS UNDER. 4. PROVIDE FIREBLOCKING, DAFTSTOPS AND FIRESTOPS AS NEEDED. 5. LUMBER SPECIES: A. POST, BEAMS, HEADERS, JOISTS, RAFTERS B. SILLS, PLATES, BLOCKING, BRIDGING C. STUDS D. POST & BEAM DECKING E. PLYWOOD SHEATING F. GLU -LAM BEAMS 6. NAILING SCHEDULE: JOIST TO SILL OR GIRDER BRIDGING TO JOIST 2" SUBFLOOR TO GIRDER SOLE PL. TO JOIST TOP PL. TO STUDS STUD TO SOLE PL. DOUBLE STUDS DOUBLE TOP PL. CONTINUOUS HEADER CLG. JST. TO PL. CLG. JST LAP OVER PL. CLG. JST TO RAFTER RAFTER TO TOP PL . BUILT -UP CORNER STUDS PLYWOOD SUBFLOOR PLY WALL & ROOF SHT. TOP PL. AT INTERS ECTIONS_ MULTIPLE JOISTS 1X6 SPACED SHEATHING PROPOSED 2 FLOOR STORAGE 14257 MACADAM RD. S. , TUKWILLA, WA 98168 3 -8 2 -8 2 =16d 16d @16" 2 -16D 2 -I6d 16d@16" 16d @16" 16d @16" 3 -8d 3 -16d 3 -16d 3 -18d 16d@24" 8d @6" (10") 8(10P6" (12 ") 2 -16d 16d @15" 2 -8d TOE NAIL TOE NAIL BLIND AND FACE FACE NAIL END NAIL END NAIL FACE NAIL FACE NAIL EDGE NAIL TOE NAIL FACE NAIL FACE NAIL TOE NAIL FACE NAIL EDGE NAIL(INTERIOR) EDGE NAIL(INTERIOR) FACE NAIL STAGGER NAIL FACE NAIL MANUFACTURED TRUSS JOIST MAY BE SUBSTITUTED FOR 2X JOISTS WHERE APPLICABLE C, Om CC im v SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila (BUILDING DIVISION, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE PY Pam* N ®. ,S01:,====. NO.2 DOUGLAS FIR NO.3 DOUGLAS FIR STUD GRADE E lt4r revfew app ®� I s i omissions. UTILITY GRADE D.F. W+ " 'h CDX PLY, 32/16 Approval of consbuodon documents doss not authodze .,p Fb -2400, DRY ADH. the violation of any ar east= o'app ed r City of Tukwila a BUILDING DIVISION ktvltWED FOR ` i CODE COMPLIANCE APPROVED AUG 2 2 2 C ity B10IN REv 3 i /l 7 /o4 ukwila DIVISION 0 r osimunimitul PAGE 1— VICINITY MAP /FLOOR PLAN 6 U U 53' PROPERTY LINE Revision Proposed Stair Landing NORTH PROPERTY LINE Y � ii ..£`.1 '- .. Z-.£ I 111111•11 y11111■11 6-.9 W W in 0 8 X'-.. X cx ';', v o m N .. N Q .. 6I, - . £ =j. y. .. £ 'I' . `k—..tr. V ----i. 1, ..06-.6 ..0'.6Z • ..9 /I 06.55 tl • U Q 97' Fire Hydrant 40' from PL k1V1tWED FOR CODE COMPLIANCE APPROVED City Of Tukwila B ILD N DIVISION i AUG 2 2 2008 E~ O r- N • 14251 Macadam Rd. Tukwilla WA 98168 Rev3 08/17/08 Perfecto 0J411cjr0 fot - M Propose 2nd FIr. Storage 3 %0 " .� 2' -6" X 3' Window Low -E PROPOSED STAIR i I REV 3 a "' r $sa c&' (Wine S 7' -3" PAGE -2 FRONT & REAR ELEVATION 12 30 YR ROOFING Existing SFR Proposed Storage 1 26' -8" xistinQ Lower Level �.-^ 30 YR ROOFING FRONT ELEVATION 21' REAR ELEVATION I ItVitWID FOR CODE COMPLIANCE APPROVED 3' -5" AUG 2 2 2008 City Of Tukwila I D N D]IVI I s N I X 4 CORNER TRIM 14251 Macadam Rd. S. Tukwilla WA 98168 Rev3 08 /17/08 Perfecto Olandres PAGE 3 RIGHT /LEFT ELEVATION & LIGHTS ELECTRICAL 3'x6' -8" VINYL STEEL MANUFA DOOR Proposed Storage Existing Lower Level 3' WINDOW LOW-E Proposed Storage Existing Lower Level \ 4 u 13' -0" EXISTING SFR 11 II RIGHT ELEVATION Existing SFR 29'-0 1116" LEFT ELEVATION Proposed Storage 2nd Floor LIGHTS /ELECTICAL 30YEAR COMPOSITION ROOF 5' -10" 14251 Macadam Rd. S. Tukwilla WA 98168 Rev.3 08/17/08 Perfecto Olandres BRACE PANEL DEFINITION BRACE PANEL CONSTRUCTED AS PER IRC 2006 NOT LESS THAN 48 INCHES WIDE OR MORE THAN 1 -FEET HIGH BRACE PANEL SHEATHING MIN. T -1- 11 3/8 PLYWOOD ONE SIDE NAIL W/ 8d @ 6" O.C. ON THE EDGES AND 8d @ 12" O.C. ON THE FIELD. PROVIDE PERIMETER MEMBERS AT OPENINGS. PROVIDE FRAMING MEMBERS OR BLOCKING AT EDGES OF ALL PLY- WOOD SHEETS. PROVIDE HOLD DOWNS AT EACH END OF EACH BRACE PANEL PAGE 4 - FRAMING AND BRACING Edge Blocking 8' • 8' 4— 30" min. On openings ' w 30" min. On openings Header for Door Opening Header Post (2) Dbl. 2X4 Studs BRACE PANEL DETAIL 2nd FLOOR BRACE PANEL DETAIL I st FLOOR Min 3/8 Plywood OR 2MW Particle Bd. One Side 8d @6" O.C. Edges 8d @ 12" O.C. Field Simpson or Equiv. HD2A w/ 5/8 Dia Bolts/Nuts/Washer OR Lap Joint for Sheathing Lap Sheathing over sill to Middle of Rim Joist at Bottom. Lap Joint for Sheathing Lap Sheathing over sill to Middle of Rim Joist at Top. Edge Blocking Min 3/8 Plywood OR 2MW Particle Bd. One Side 8d @6" O.C. Edges 8d @ 12" O.C. Field All Horizontal Joist to be Blocked with Flat 2X stock REVIEWED FOR CODE COMPLIANCE APPROVED AUG 2 2 2008 City Of Tukwila ' ILDIN DIVISION 14251 Macadam Rd. S. Tukwilla WA 98168 Perfecto Olandres PAGE -.9- CONNECTION DETAIL OF NEW WALL TO EXISTING Existing Roof and Truss New Roof with 2' OverHang Flashing Typical: Step or Continuou New 2x Stud : Nail New Wall to Existing St Use Simpson Strap to join new and old studs Existing 2x Stud CODE COINp FOR ������ ONCE AUG 2 2 2008 City Of Tukwila 14251 Macadam Rd. S. Tukwilla WA 98168 Perfecto Olandres 16' co N CD Page -6 AS -BUILT FLOOR PLAN OF EXISTING PL RkInEYVWD FU 75' -0" • I . Crh N x 4' -0" 3' -0 x 6' -8" Dinning Kitchen 0"x2'2 11' -9" x 6' -8" CO Master Bedroom 2' -4 "x4' ndow Low -E Window Low -E Revision • 3 M 00 00 zer -7L U, PropertyLine 4 %0" Laundry Area BathRoom x 5' Window Low -E 2' -4" x 5' x Window Low -E 4'x4' of Window Low -E 1%4 75' 6%11" 3' -0" x 2'- X IL Living Room 1 -0 " DECK Existing N M 3' -0" x 6' -8" 3 . -0 " x 6' -8" 21'- 4" 13' -3 1/2" 1• cri EXISTING SFR (AS- BUILT) 3 10' -9" Bedroom2 4' -0 1/2" 12'-4" I NCE A PPROVED AUG 2 2 2008 City Of Tuk BS LDIN Dn/ISION 4'x4 Window Lo 14251 Macadam Rd. S. Tukwilla WA 98168 Rev. 3 08/17/08 Perfecto Olandres 1 -tyLine 2x Stud (wall) Existing Lower Building Framing 2 (DBL) 2X4 Studs K ,+ Existing 2X Floor Joist Page -7 EXISTING LOWER BLDG FRAMING & PLAN Existing Lower Building Floor Plan EVIEWED FOR`_` E COMPLIANCE APPROVED AUG 2 2 2008 City Of Tukwila ILD N DIVISION 4x 6 Solid Wood Support Beam 14251 Macadam Rd. S. Tukwilla WA 98168 Rev3 08/17/08 Perfecto Olandres Newel Post Exposed 4 X 4 Treated ■ Oi 3 Lag Screw Skirt Board n !7 '! Stringer c O m �i■'■ Riser -I M CO CG Lag Screw o i;1 CO Notched Newel PAGE 8- STAIR DETAIL Angle Bracket 4 - 3/4 7 -1/2" NEWEL REVISED STAIR DETA 3' Typical Hand Rail 2x2 Pickets @ 4 1/2" O.C. Tread Stringer RV1CW D FOR - CODE COMPLIANCE APPROVED AUG 2 2 2008 B ThThFfujia �IN r i k ....... Starting Newel 2nd Level it u• Edge of Tread II — Face of Stringer 1411 Pickets Center line Bottom of Newel Post Exposed 4 X 4 Treated 14251 Macadam Rd. S. Tukwilla WA 98168 Rev.3 08/17/08 Perfecto Olandres 0 OM O CC gv ROOF CONSTRUCTION ROOFING OVER FELT PAPER 1/2" OSB OR PLYWOOD Insulation Baffle Vented 2X Block Insulation or Solid Blocking Facia, Gutter, Down Spouts PAGE 9- FOUNDATION AND CROSS SECTION Window/Door Opening With Casing Anchor 1/2" Dia. 7" Embedment 6' O.C. space with I /4 "x 3 "x3 "washer Sill Plate 2 Bolts per plate. One Bolt located 12" from end 12" min below Undistu grade Typical 2x 4 Siding Exterior Wall: T1 -11 Siding Building Tyvec Wrap 1/2" Sheating RF30 OF Insulation 2x4 Upper Plate Continuous Rim Joist 2x4 Lower Plate Existing 1st Floor 2x4 Stud 16" O.C. I #4 continuous 15" min width FOUNDATION AS -BUILT Headers 8" Concrete Wall (PRESUMITIVE) 2X4 Studs @ 16" O.C. R15/R18 Batt Insulation 1/2" Gypsum Baseboard Typical Floor System: 1" T &G Plywood 2x Floor Joist @ 16" OC Cross Bridging or Blocking TYPICAL CROSS SECTION DESIGN 1500psf presume soil load bearing Manufactured Roof Trusses 2X Truss or Roof Framing R38 Attic Insulation 1/2" DryWall KtVltWJJ f-OK CODE COMPLrLNCE APPROVED AUG 2 2 2008 City Of Tukwila BUILD �. ®MS IQN DRAWING #DCD H008 APPROVED REV #2 DRAWING #DCI) H009 APPROVED REV #2 14251 Macadam Rd. S. Tukwilla WA 98168 Perfecto Olandres