Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-375 - WESTFIELD SOUTHCENTER MALL - AMERICAN EXPRESS - EXHIBITION CENTER
AMEX GLASS BOX 3648 SOUTHCENTER MALL D08 -375 Parcel No.: 6364200010 Address: 3648 SOUTHCENTER MALL TUKW Suite No: Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Phone: 206 718 -0960 Contractor License No: BNBUII *990K3 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF NEW MALL SPACE doc: IBC -10/06 CityIllf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Tenant: Name: AMEX GLASS BOX Address: 3648 SOUTHCENTER MALL , TUKWILA WA DEVELOPMENT PERMIT Contact Person: Name: MARCIA PEDDICORD Address: 633 SOUTHCENTER MALL TRAILER #3 , TUKWILA WA 98188 Phone: 818- 402 -8923 * *continued on next page ** Permit Number: D08 -375 Issue Date: 07/22/2008 Permit Expires On: 01/18/2009 Expiration Date: 09/12/2009 Value of Construction: $150,000.00 Fees Collected: $3,054.00 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: II-B Occupancy per IBC: 0019 D08 -375 Printed: 07 -22 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: doc: IBC -10/06 City orI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Thee: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N LAY Permit Number: D08 - 375 Issue Date: 07/22/2008 Permit Expires On: 01/18/2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rformance w . I am thorized to sign and obtain this development permit. Signature: ` - ( � Date: -1 Z 2 , O q3 Print Name: Ni r - - 4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -375 Printed: 07 -22 -2008 Parcel No.: 6364200010 Address: 3648 SOUTHCENTER MALL TUKW Suite No: Tenant: AMEX GLASS BOX 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -375 Status: ISSUED Applied Date: 07/15/2008 Issue Date: 07/22/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: doc: Cond -10/06 D08 -375 Printed: 07 -22 -2008 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 nun) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of the means of egress system shall not be diminished along the path of egress travel (IFC 1003.6) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 25: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: All sprinlder system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212 -80) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) doc: Cond -10/06 D08 -375 Printed: 07 -22 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 33: Call the Tukwila Fire Department at 206/575 -4407 for approval of any system shut down. Have job site address, name and the Tukwila Fire Department Job Number available to confirm shut down approval. (City Ordinance #2051) 34: Walls of corridors serving an occupant load of 30 or more shall be of not less than one -hour fire resistive construction and the ceilings shall not be less than that required for a one -hour fire resistive floor or roof system. (IBC 708.1(4)) (IBC 1016.1 Table 1016.1)) 35: Required fire resistive construction, including occupancy separations, area separation walls, exterior walls due to location on property, fire resistive requirements based on type of construction, draft stop partitions and roof coverings shall be maintained as specified in the Building Code and Fire Code and shall be properly repaired, restored or replaced when damaged, altered, breached, penetrated, removed or improperly installed. (IFC 703.1) 36: When fire resistive floor or floor ceiling assemblies are required to prevent the vertical and horizontal spread of fire and smoke, the assembly shall be maintained. (IBC 712.4.2) 37: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 0700. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * * continued on next page ** D08 -375 Printed: 07 -22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Y ■ - C t, .. Print Name: t•-/k iNr2 - A . 1,--1 f L- L-1 A - (2., doc: Cond -10/06 D08 -375 Date: J U L - 1 2.2 0, ordinances governing or local laws regulating Printed: 07 -22 -2008 Tenant Name: /- t.a4C - � la s 5 R V Property Owners Name: 1,(J e s/- � e f� 6 crer r Mailing Address: ( / (6l 1,,t) , 16 // , re_ — 810 A. 11 fn t lent/ Site Address: Name: Mailing Address: 6 Sept P__., E -Mail Address: hl ed Contact Person: T \Ar2 - 1. 1 - 1 4 g- P E -Mail Address: N4. LII t:1.fA1Zp BOILREP 9 Contractor Registration Number: b t4B 13 i l ' 1.10K3 Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwcitukwila.wa.us Y k e"=d e--( 17, L R G re t f ( q . ( be) 1 t.t Y ii JC°., -t to Jef-c P ing Permi. Mec Permit No. Plumb ing/Gas Pe No rmit .N Pub lic Wor Perm No. Proj ect No. .1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: (-, = .2b , 4.30 i 0 Suite Number: City CONTACT PERSON who do we contact when your permit is ready to be issued Day Telephone: 'Tra, /4?-7- 3 To ( <lc City e --4-( Fax Number: GENERAL CONTRACTOR INFORMATION ` — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 1, PI\l8(lt -PE4 r Mt. Mailing Address: 2604 FOop(F hOSWO6 r Surf 350 '56At'C c i 9810 State Zip City Day Telephone: Z�. 3,5Z- - 34 Y 3 Fax Number: Z DG • 3R2 . 3 Expiration Date: t /I Z / ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 7 Se Me toit 87q City State Zip Day Telephone: 20‘-- `144., (- .) Fax Number: i ar'o we use only) New Tenant: Floor: .3 Yes ❑ ..No State 3 Zip k/ - * 2 - 723 60>4 State ° 44 (- q mil' ENGINEER OF RECORD -; All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q: \Applications.FomtrApplications On Line3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Zip Page 1 of 6 BUILDIiNG PERMIT INFORI ION .- 206 -431 - 3670 Valuation of Project (contractor's bid price): $ / S be-� Existing Building Valuation: $ Scope of Work (please provide detailed information): 0-17 ki S4 r LL, eft ere 6 P h e.g.., re 1-4; S,t'J Will there be new rack storage? ❑ Yes Provide All Building Areas in Square'Footage Below 1�`.Floor: 2 " Floor 3'":.Floor • Floors .Basement .Accessory Structure* • Attached Garage •• Detached Garage :Attached Carport . • •Detached Carport Covered Deck ':i • Uncovered Deck • Existing Interior Remodel Addition; to Existing • Structure . . ' New / 834 Type of ` Construction, per LL -1 Type of Occupancy per IBC •'. . PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes ra No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: [�� Sprinklers �� Automatic Fire Alarm Q: tApplicationstFomu- Applications On Line'3 -200h - Penmt Applicahon.doc Revised: 9.2006 bh 0.. No If yes, a separate permit and plan submittal will be required. Handicap: ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes p No !f "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOT Applicable to all permits Date Application Accepted: Q: \Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 Sh in t ] City is ap, J .,ticati i Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 1UTHORJZED AGENT: Signature: i � l Date: 7 /1/ /oB Print Name: (`` N) 4 Day Telephone: 2 06 • 7f ?) C 7 e, 4 --1 Mailing Address: 7(0 ( 1,.y,,. Aki F Cc>P c p State Zip Date Application Expires: Staff Initials: ( W Page 6 of 6 1 Receipt No.: R08 -02698 Initials: WER User ID: 1655 Payee: MARK HILLIARD ACCOUNT ITEM LIST: Descript PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: D08 -375 Address: 3648 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/15/2008 Applicant: AMEX GLASS BOX Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11482 360.00 Account Code Current Pmts 000/345.830 360.00 Total: $360.00 Payment Amount: $360.00 Payment Date: 07/22/2008 01:13 PM Balance: $0.00 5178 07/22 9710 TOTAL 360.00 doc: Receipt -06 Printed: 07 -22 -2008 Receipt No.: R08 -02565 Payee: BNBUILDERS ACCOUNT ITEM LIST: Description lion.! Raraint -OA BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 35128 2,694.00 000/322.100 000/345.830 000/386.904 RECEIPT Parcel No.: 6364200010 Permit Number: D08 -375 Address: 3648 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/15/2008 Applicant: AMEX GLASS BOX Issue Date: Initials: WER Payment Date: 07/15/2008 09:51 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 1,630.00 1,059.50 4.50 Total: $2,694.00 Payment Amount: $2,694.00 4847 07/15 9711 TOTAL 2694.00 Printwri 07 -15-2008 COMMENTS: Type of Inspection: ?v `�' t � : 1� Address: 36-4il Sc 4/41 I Date ed tJs S . M err ,t Ai AA A .•.' 2-2--ti/ p.m. Requester: i. ; P' r .: ( 'C� 4 . t . ' ., t 1 p .if t1 Project: ., 1 iaiT f on A AA- (1 - � 1)rc t'r Type of Inspection: ?v `�' t � : 1� Address: 36-4il Sc 4/41 I Date ed tJs S , , Q `1 c�vl Special Instructions: • Date Wanted: .•.' 2-2--ti/ p.m. Requester: Phone ,: _ w q j _....q(40.70 INSPECTION N0. INSPECTION RECORD O Q�, -3 ? + Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION (P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Q PERMIT NO. Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspect Date: + Receipt No.: Date: COMMENTS: Type of Inspection: - -I 1"- Pi p 7'r1YrirAtv5...- r A)e. )4----ii 3 / ram Ai A 4 f /0 e ass A/,1/ /r- �`'P-C/ i i rrl/Cf /4/–‹/4/41 1 / 3 A/el m. Requester: /14rr/ r'gS /4 Lt.'4 // /0 re .C3 - 0 rip) /rn s/I /2- t o -d-g Proje t : P f v i AJ ' , &*5 Type of Inspection: - -I 1"- Pi Addres • 3 Lip) f 1 A ( ( Date Called: nstructions: Special Instructions: . - . - / . Date Wan d: ` 1 I -2D /Q P m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION tF 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. INSPECTION_RECORD Retain a copy with permit 1 !Date: D°-37 PERMIT NO. Date: /1 Id 7 17$60 REINSPECTION FEE 5EQUI D. Prior to inspection, fee must be pa j t 6300 Southcenter Blvd., Sui a 100. Call to schedule reinspection. COMMENTS: / �/� 24) --3.--- -7,-,- 4- X9/7/, / . „,, Sj• 4A7 i)/� 4.-„,/,/69,/, _.2-4/40ref i /tom `e 4v.s... / . Date Called: ' 7 /t'5 JAit /47 'r V 2 j) ] ` ?/ 111' ��i e �>x 0. 14�� T ox r616) Te d TO �► -30 -64 Phone No: C 4 G 1 --- g 0 i ,.. .---), Probe t: ,'2 ref/ t g /s C Type of Inspection: / /iv" L v Address: G/0 in 4 / / Date Called: Special Instructions: Date 1p(antec(: _ az 0. 5- % g/ Phone No: C 4 G 1 --- g 0 r INSPECTION RECORD Retain a copy with permit D08-375 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - ❑ Approved per applicable codes. r ec ipt No.: gel Corrections required prior to approval. 4 1/ E l .00 REINSPECTION FE EGU inspection, Prior to ins ection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. * I specto Date _ /e ” 'Date: Project: PIti .(11), 63 4- .1,5,.4 Type of Inspection: ! ' 1.ta Addrre Pl iC Date Called: Special Instructions: Date Wanted: /{ Q a.m � . Requester: 1/114-r dd Phone No: 2 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ' R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -361(0 ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 12.A. 1 0 Tar 30 a is LZ - '4 , t2 M H.„,.f5 air T r ) ©fr ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: Prooj Type of Inspection: U Address: 36411( mil Date Called: Special Instructions: - Date Wanted: 2 3" off �p Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Cgj Approved per applicable codes. nos -3 (206)431 -367 Corrections required prior to approval. f� COMMENTS: r im. :.•� �r� Date: " o ( Inspector: fl $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: a..).0 :\ - -4 Id A C - . A.vc.4. - .: Type of Inspection: 1�^ �-- EA , . r� �<_ C AL.- Address: 2 4 yg 'Suite #: .S •C . r-NdtL L. Contact Person: Special Instructions: Hood & Mitt: Phone o.: Needs Shift Inspection :. _ Sprinklers: $ Fire Alarm: Hood & Mitt: Monitor: (,,; p, n/ Pre -Fire: . ' - Permits: p •` -,, Occupancy Type: A a.-. 1 M.a 5� ahM .Arab G'ci , Niziea " 1.:_CA'v �A':a�tii INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila. Wa. 98188 206 -575 -4407 Approved per applicable codes. ;OM M ENTS: g/ L- ` �r� I1.1 • 1 Date: gk/ H 4 Inspector: 6;j y/ 1 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from • • the City of Tukwila Finance Department. Cali to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 Retain a copy with permit bo 3 - PERMIT NUMBERS n Corrections required prior to approval. T.F.D. Form F.P. 113 Project: 'S - jam,,, e , t e_ ' Type of Inspection: L.- Fire Alarm: Address: 3 6.413 s t Q . i, Suite #: tact Person: v`i L.0 " Permits: Special Instructions: Phone No.: • Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: . Monitor: Pre -Fire: Permits: Occupancy Type: - •izx.'as�sus. w. esr , . :tszwmex:vst'n,�@e.;x:?'sw� INSPECTION NUMBER El Approved per applicable codes. IIn v aj s INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 CITY OF TUKWILA FIREDEPARTMENT 1 Date: /lb )45 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 rororrections required prior to approval. COMMENTS: ._.._�..,.�..�... _.___ �.. _.._ w.�.���.... -. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from ity of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 s. • Project: f -r r x 64..Ass 1 , Type / o f f Inspection: ,A Address: N se , Suite #: i n Contact Person: +74r10 Hi i Special Instruc Permits: Phone No.: za*- ?a- igg, Needs Shift Inspection: - Sprinklers: • Fif&Alarm: Hood & Duct: Monitor: • Pre -Fire: Permits: Occupancy Type: ' INSPECTION NUMBER NSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 COMMENTS: p�►�+ fi r' - O/& - h 409144 ' W/ delifE Sj2'WAWA-5 I MI4'L, -W_ — It proved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 n Corrections required prior to approval. n $8.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Cali to schedule a reinspection: T.F.D. Form F.P. 113 Project: frineA kOL,W14.-. Type of Inspection: Cauca, . Address: 3 bL/g S c m e2L Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: , Sprinklers: . Fire Alarm: y - Hood & Duct: ,c/ Monitor: , Pre -Fire: Permits: ' Occupancy Type: ... I J4.' 4L£ V�IiCW^+• lrtL." t+ waliKVt"' �VUw� 'Y1sk"4.Ni^rrwlGk'3 + %x'i'ik t±�?YS9f.Wt".;4tifu'i+=' ': i" s41wtC+' i! :v.'+ibr.':ei!"i�5's:"wYSLtetl sf'.d10E% ^i'Pn`a'h+.'+tr.; .i'wsC'f.X,`" n++. u+{ eiN4k:, r! a'' f1FTG' M�a�MMI A•xn!W?- 4' +lII}5 ^G•.?'u.Se. INSPECTION NUMBER INSPECTION RECORD ,'Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT - PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Approved per applicable codes. Corrections required prior to approval. COMMENTS: IL — i , ra cep P eet-' -L 5 .aJ 49 sr p, e , ;A &. ju / - s< i1 t' OK- i . e'r'e e , r�r.�r,�J �' ' ? l i 9ii / /».�.ts c,frtit Inspector: • Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance De fartrnent. Call to schedule a reinspection. Word /I ispection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 1 RECEIVED CITY OF TULA JUL 212008 PERMIT CENTER r : -. . _.. _. ANF & ASSOCIATES Consulting Structural Engineers STRUCTURAL CALCULATIONS 4 bCil4-ll.S For FILE COPY Pertmlt No. REVIEWED FOR CODE COMPLIANCE APPROVED BUILDING DLY $ION, C C.D u O cfc-GLG N C, s►-.w-r rLvo 4y ? L T ‘ 2DL Ar t 4 Architect k) cr f 1 ELo El E5 L4 N Co 14518- u-c- to r�.l 6 100I Cut (.401/Le C-vo it - L-CIS A e C.c— S c-/? 00 25 (1 4 S - 445 0() CORRECTION 9420 Telstar Avenue, Suite 118, El Monte, California 91731 Tel: (626) 448 -8182 Fax: (626) 448 -8092 Email: anf1688 @pacbell.net LT R# 1-s Dot- Tel: (626) 448 -8182 ANF & ASSOCIATES Fax: (626) 448 -8092 Consulting Structural Engineers E -mail: ant1688@pacbell.aet 9420 Telatar Avenue, Suite 118,131 Monte, CA 91731 C Lc t O C t LC N �-� J O &1 t2-o f 11-0 `rO C� (L LO I A. 4 , � s4ta i..- tticwft4 C. s lv I eta) 'rl2 ACGt -s�-r 1 4 -at/Lewd) pop Joe No U TV\ C BY v DATE ?1 n a $K OF 6si Yr 11 18 Vin -c.0 H ernom.. 4 ?loop lt.w►vruv'j ■+ C.-et wei w L grf-- Ce- .1-1 NC = C(1)( I1, = 3 el 1t04( 1 =`2-,1 0_k C.b ry n) To C) M c-c Sc-i-T- D n t. G scr r....J To -- ) 1g q A t1 ST - ,9e -t-k f"L � - re , . (4* c G t:M ?rrer.-t t(kL., '°'''') ANF & ASSOCIATES Consulting Structural Engineers 9420 Telster Avenue, Suite 118, El Monte, CA 91731 a x tzT H c'ZA -c _ v 0 Tel: (626) 448 -8182 Fax: (626)448 -8092 E -mail: aof1688@pacbell.net 3(). co> GIA/St-K +44.11 STMT • / b ®� Win- 4 - / 0 r & . A -A Lo A,'J = 5,( 5' Joe No. 2S1 O tiO S° 7 CCznrr- By DATE SH. OF Pi . E= G 0' CL M4-. 502,6-K q c, 0 -F el.- i L° @ k1Q - 540,40 1 0.1c k c7 S 14.7feovr t- c & 1.1 t tdc( el- &sr- vit S�. cl .s i p �F- U 3 .67 m, 7© 02L < ? /; o % . Tel: (626) 448 -8182 A N F & ASSOCIATES Fax: (626) 448 -8092 50 Consulting Structural Engineers E-mail: anf1688@Pacbell.net 9420 TelatarAvenue, Suite 118, E1 Monte, CA 91731 CLr, C riLt.4I (�sT -cN C ! ,o e s-1 L X 1 I' X 7) = I . o /2-p = 2.5 , � s ! o.85 * Gui; 33'S •D 1..5/ t. ea X3 ( + # Joe Na ZS 0(p Br P DATE -4) - �8 S►� OF • z5 prvD v 10 4- - o '2/6 S S1<. , •7/6 0 3_,) Gu 6 c-e Goatac t N Te-ftistew '1i - JO 8w Two 82-21-cc - -e ms _ � f C D vc -H y elvcoil In) - ! — !.vc P v�- c - ° X (. ?3 GONN - Wt/l-e 1 -1 - cE T° fct 1 - L C-E-- 1.Ltt mac_, -€'r 2 5 e t f. 1) n- cc -crcN 5s TeJJtN ANF & ASSOCIATES Consulting Structural Engineers Tel: (626) 448 -8182 Fax: (626)448 -8092 E -mail: ant1688@pacbell.net 9420 Ulster Avenue, Suite 118, El Monte, CA 91731 GL-0 L 1 /V C , GDS tf Joe No. By DATE 7- 16 - 4 ' 8 SH._OF Calkir eft-- n l l Att-' T = 3 x 4 Ga x • ec A( . 272) Tel: (626) 448 -8182 ANF & ASSOCIATES Fax: (626) 448 -8092 5 6 u2-04 Ce-J -r�V Consulting Structural Engineers B -mail: anf1688@pacbell.aet 9420 Telstar Avenue, Suite 118,131 Monte, CA 91731 Jos No. ° `F' By DATE SH. .OF 1 1 1 5 , It.ce u-foteyriul -L- ►L� c�rJ :�/ cc.A+tp . t.--w ►1-rr 7 "DIP ( pi7tstNp-rr) Gt1Qt$-i nv-i - r 2 e ; 4LL t , (-n4-i• L0 A- J S '2401- a-o w 4 = 7-2-0 r k 4; G ir C� M t Ne., v -1t La 000 o 't co- G , () ano u+ � 61 '4-'1 4! D v `�f ""tr1 .i v o `o ` (E)t - vc- s o b 1 - Z g t P Y bbo C 4 C --eye a4) y a Au_ - 11.1.11-tsft-CAO o� 4- o 0-c • w•2: en-. 5 (-1.- (}.euse,;) F Lo I�r� S usionsim mmoimmomfolmou i as Emassins ,WRILIIMEMEIr 542- t 7 . B CZ 5k 3- O71&05 p c_ArNi LA-r 43 S dO S -fort° e4-1 tc.t CLo u..4 t 'd,c2 t Sr n-u 7 o" &A- c.vgNi �I °7 0 d z o m x x a a 1 03 0 6 H 1 dhi it i�' & s dazi ci10 �� g L 1 0001 4 , .44c7/ si 4_6 (''1a - r / 0-VQ -7 14-1i 04 I n/17 J- v- ill/x.0 6 N 0—rICI--)7 N a: al9f4 8°' L ° Z�s I - c - fo),_.11.- 4' k e3k -t-2 1 - - yrpo i N y) .1.r►a - � S l ►�u �N�'t ooa i d -(0 Cad Its/ o, d ):1 1M-u i N-r v4o 1 l i) Q S'u 1 r J 1 $ 1 Li. i d Larnukc . . WOI d . Tel: (626) 448 -8182 ANF & Assocr s az ( S o ufc c &JT Consulting Structural Engineers 9420 roister Avenue, Suite 118, El Monte, CA 91731 C &iLlw4 C -Lo t�J 5 ( r)(2•T lg 4 A ,�i 1_/ •c�P� M &IAL. dOcK t Z $ IlAtJcen, te'T€ et-t? oLT AN �I- Jos No. Z C BY DY DATE 7 - (6 , 0 8 "4 3/ Pu- -Ltn epr+oc-0 T© (s) D Ck 4 9 Ict p J' July 18, 2008 Marcia Peddicord 633 Southcenter Mall Trailer #3 Tukwila, WA 98188 RE: CORRECTION LETTER #1 Development Application Number D08 -375 Amex Glass Box — 3648 Southcenter Mall Dear Ms. Peddicord: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messen;aer service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, ( 10/S9 , t051 Brenda Holt Permit Coordinator encl File No. D08 -375 • City of Tukwila Department of Community Development Jack Pace, Director P:Pennit Center\ Correction Letters\2008\D08 -375 Correction Ltr #I.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo • • Date: July 18, 2008 Project Name: AMEX Glass Box Permit #: D08 -375 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24,06; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide an engineered design to show how the clouds shall be braced to resist seismic forces. Include a design detail to show how the clouds shall be mechanically fastened to the structure above. (IBC 1604.1, 1604.2 & 1604.9) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. July 11, 2008 Mr. Robert Benedicto Building Official City of Tukwila Department of Community Development 6300 Southcenter Boulevard Tukwila, WA 98188 -2544 RE: Request for Overtime Plan Review Amex -Glass Box, #3648 Southcenter Mall, Tukwila, WA 98188 Dear Mr. Benedicto: Sincerely, Cc: Tenant file esffleld Westfield, LLC 633 Southcenter Mall Trailer #2 Seattle. WA 98188 Telephone (206) 802 -6010 Facsimile (206) 246 -7043 To expedite the plan review process, please use this letter as my formal request to utilize the overtime plan review procedure at the City of Tukwila. I understand that the cost of this service is 1.5 times the standard hourly rate and I will be billed for a minimum of four hours. I agree to review and respond to any and all plan comments in an expeditious manner in order to keep the plan review process moving quickly. I will assume all payment for the overtime plan review. Said cost will be accumulated during the plan review process and when the plans are approved, the City of Tukwila will require that the overtime cost be paid on or before the building permit and approved plans are picked up. I request that this overtime review process be initiated immediately for this set of plans only. RECEIVEr JUL 15 2008 PERMIT CENTER ACTIVITY NUMBER: D08 -375 DATE: 07 -21 -08 PROJECT NAME: AMEX GLASS BOX SITE ADDRESS: 3648 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: o 1 Bui .(n uivision Public Works Complete Comments: Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: • PERMIT COORD COPY • OPY Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ DATE: DATE: Planning Division TUES/THURS ROUT G: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: ❑ Permit Coordinator ❑ DUE DATE: 07 -22-08 Not Applicable ❑ Perini'f.Cenfer °U�Se.Orily : ' , INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 08-19-08 Approved ❑ Approved with Conditions [1 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center .Use'Only r. CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -375 DATE: 07-15-08 PROJECT NAME: AMEX GLASS BOX SITE ADDRESS: 3648 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENT . : ilec6 : • 11 % in ' ivlsion Public Works ► Structural 9/6 NA, I DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUES/THURS RO TING: Please Route • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing slip.doe 2 -28-02 nt1 cv foci l Fire Prevention Incomplete Structural Review Required ,M,e- /Wu 1-11'01' Planning Division !� Permit Coordinator DUE DATE: 07 -17 -08 Not Applicable Comments: r:'P`rilflppt'Cel�tsf t�lseOnly /� e` � • ;�.. _ ., • F ti M - :� •'Y : a'�:� °7 �� .". '-��'"�... +•`r n'�� ..i . ..., , !.. )11T.;:.......-;:z.1 ; l � .,.., �. ? ~` .;'A ;"' ; v, • • .. • .. ' I:' :+e. fir '�'• ` ,: INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 08 -14 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Er Notation: REVIEWER'S INITIALS: DATE: ' "Permit Centet•. Use Only' . ^. • CORRECTION LETTER MAILED: - >. N • Date: /A. • City of Tukwila \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us �r RJ+at'arar.rss' 31..09%!.14 RR KIK i SUB, tIT . A Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. 6(- - - Responseio Incomplete-Lett ice_ (x( Response to Correction Letter # q�p ❑ Revision # after Permit is Issued �JUC ❑ Revision requested by a City Building Inspector or Plans Examiner 21 48"71..4 PF or rEH Plan Check/Permit Number: Project Name: 1k r 61.4655 X Project Address: , 6 ,- 36 NPR JCAC - Nr Frr rA l r VA Q 'el ` O Contact Person: r'iN Phone Number: - Zi5 C 71 tee71 Summary of Revision: � T - �lcv`^? D C pl S , Fc,c `c - - r S€ i -' \L ,N�c. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Cv\c X ( T N Entered in Permits Plus on jti 2 t Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS l3 SURETY CO 10335590008/30/2001 Until Cancelled $12,000.0009/06 /2001 2 TRAVELERS CAS ft SURETY CO 103355900 01/01/2001 08/30/2001 $6,000.00 02/05/2001 1 UNITED PACIFIC INS CO 6877797 09/07/2000 Until Cancelled 04/27/2001 $6,000.00 Name Role Effective Date Expiration Date BASTIAN, BRAD PRESIDENT 05/23/2001 NIELSEN, JEFF VICE PRESIDENT 05/23/2001 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. B N BUILDERS INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company B N BUILDERS INC UBI No. 2067180960 Status 2601 4TH AVE STE 350 SEATTLE WA 98121 KING CORPORATION License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602056687 ACTIVE BNBUII *990K3 CONSTRUCTION CONTRACTOR 5/23/2001 9/12/2009 BASTINB000OJ PURODSI984JN GENERAL UNUSED Business Owner Information Bond Information Insurance Information • Page 1 of 2 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= BNBUII* 990K3 07/22/2008 GENERAL G0.0 COVER SHEET AND SHEET INDEX G0.1 CODE STUDY ARCHITECTURAL A2.1 PLANS, ELEVATION 1. 2. 3. GENERAL NOTES S AND DETAILS 15. R- VALUES AND U- VALUES LISTED HERE ARE 1vINIMU INSULATION: ROOF: MINIMUM R -38 FRAv1ED WALL MINIMUv SLAB ON GRADE: R10 INDEX OF DRAWINGS TYP. FIN. FL. EL. 6. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL WOOD BLOCKING IN ALL WALL ATTACHED ITEMS. 7. ALL PENETRATIONS THROUGH WALLS SHALL BE SEALED WITH FIRE STOPPING RATING AND SMOKE STOPPAGE. : R13 + R3.8ci SOUTHCENTER MALL RENOVATION 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 SUMMARY OF WORK GLAZING WINDOWS UP TO 30% GLAZING FRACTION: U -VALUE .55 WINDOWS UP TO 45% GLAZING FRACTION: U -VALUE .45 Westfield lass Box THE WORK INCLUDES THE FOLLOWING: A TENANT FIT OUT OF AN EXISTING SHELL SPACE AT SOUTHCENTER v1ALL, TUKWILA, WASHINGTON. CONSTRUCTION WILL INCLUDE THE FOLLOWING ELEv1ENTS: FINISHED SURFACE ON EXISTING NEW FINISHED SURFACE ON EXISTING CONCRETE FLOOR, INSTALL NEW GYPSUM "CEILING CLOUD" SYSTEv, INSTALL NEW GYPSUM BOARD PROJECTION WALL AND STOREFRONTS, AND INTERIOR PAINT FINISHES. INSTALL NEW LIGHT FIXTURES, EXTENDING DUCTWORK FOR v1ECHANICAL GRILLES. GENERAL NOTES APPLY TO ALL SHEETS: ALL DIVE \SIONS ARE ACTUAL AND ARE TO FACE OF STUDS, FACE OF CONCRETE WALLS, FACE OF C OF COLUM \S, U \LESS NOTED OTHERWISE. FLOOR SPOT ELEVATIONS ARE SHOWN THROUGH SPECIFICATIONS MAY EXCEED THESE VALUES. PROVIDE VALUES AS LISTED ON DRAWINGS OR SPECIFICATIONS. 16. CONTRACTOR SHALL VISIT THE SITE. FAMILIARIZE HIM /HER SELF WITH EXISTING CONDITIONS AND REVIEW AND UNDERSTAND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND CONDITIONS PRIOR TO BEGINNING ANY WORK AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCY. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CORRECTIONS AND REPAIRS REQUIRED DUE TO HIS /HER FAILURE TO DO S0. v1U WALLS, FACE OF FRA v1ES. OR CENTERLINE 4. ALL WALLS SHALL EXTEND TO UNDERSIDE OF FLOOR OR ROOF DECK ABOVE UNLESS NOTED OTHERWISE. 5. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NONBEARING 'WALLS FOR 1 -INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE SAFING INSULATION OR FIRE STOPPING v1ATERIALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. METAL STUD PARTITIONS FOR THE PROPER ANCHORAGE OF MATERIAL AS REQUIRED TO ACHIEVE THE RESPECTIVE FIRE - RESISTIVE 8. T E OWNER SHALL BE RESPONSIBLE FOR PROVIDING THE CONTRACTOR WITH ROUGH -IN INFORv1ATI0N NECESSARY TO ACCOMMODATE THE INSTALLATION OF OWNER FURNISHED AND INSTALLED OR CONTRACTOR INSTALLED ITEMS. 9. THE CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR INSTALLED ITEMS IN THE CONSTRUCTION SCHEDULE, AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEv1S. 10. GENERAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL WORK WITH THE v1ECHANICAL CONTRACTOR. 11. GENERAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL WORK WITH THE ELECTRICAL CONTRACTOR. ON PLANS. 12. DIMENSIONS FOR DOOR AND WINDOW OPENINGS ARE SHOWN NOMINAL. ALLOW FOR 1/4 -INCH (SHIv AND SEALANT OF EXTERIOR FRAIvES. 13. SCRIBE GYPSU vl BOARD OF WALL AND PARTITIONS TO IRREGULARITIES OF DECK ABOVE. SEAL TIGHTLY AROUND ANY PARTITIONS. 14. ARCHITECTURAL FINISHED FLOOR ELEVATION O' -0 ". M VALUES ONLY REQUIRED BY CODE. INSULATED v1ATERIAL INDICATED IN DRAWIN PERMIT SET 08 -11 -2008 GS AND VICINITY MAP PROJECT LOCATION 17, SOLELY AS A CONVENIENCE TO THE OWNER AND CONTRACTOR, THE ARCHITECT v1AY INCLUDE DOCUMENTS PREPARED BY CERTAIN CONSULTANTS (OR I \CORPORATE THE RECOMMENDATIONS OF SAND CONSULTANTS INTO DOCUMENTS PREPARED BY THE ARCHITECT WITHIN THE SET OF DOCUMENTS ISSUED BY THE ARCHITECT). IT IS EXPRESSLY UNDERSTOOD, THAT BY SUCH ISSUANCE, THE ARCHITECT ASSUMES NO LIABILITY FOR THE SERVICES OF SAID CONSULTANTS. 18. ALL WO=RK AND MATERIALS SHALL CONFORvI TO THE LATEST ADOPTED 2003 INTERNATIONAL BUILDING CODE AS Av1ENDED, ALL ORDINANCES AND REGULATIONS OF THE CITY OR COUNTY WITH JURISDICTION AND SPECIAL REQUIREMENTS INDICATED IN THE BUILDING SUMMARY OR THESE GENERAL NOTES. 19. WHEN REQUIRED EXIT DOORS SWING OUT OVER AN EXTERIOR LANDING. THE LANDING SHALL BE v10RE THAN 1/2" BELOW FINISHED FLOOR. 20. CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS AND COMPLY WITH SAFETY REGULATIONS AND RESTRICTIONS AS REQUIRED FOR WORKERS AND PEDESTRIAN PROTECTIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT. PROVIDE PROTECTIONS AS REQUIRED TO PREVENT ANY DAMAGE TO EXISTING CONSTRUCTION WITHIN AND ADJACENT TO JOB SITE WHERE DAMAGE OCCURS. THE CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED AREA AND /OR v1ATERIAL AS REQUIRED TO THE OWNER'S APPROVAL AT NO ADDITIONAL COST. THIS REQUIREMENT SHALL APPLY CONTINIOUSLY AND NOT BE LIMITED TO NORMAL WORK HOURS. 21. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TOOLS, TRANSPORTATION, UTILITIES, OTHER SERVICES AND RELATED TASKS NECESSARY FOR PROPER EXECUTION OF THE CONSTRUCTION REQUIRED BY CONTRACT DOCUMENTS. 22. ANY REVISION OR ADDITIONAL WORK REQUIRED BY FIELD CONDITIONS OR LOCAL GOVERNING AUTHORITIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. 23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS, LICENSES, INSPECTIONS AND TESTING INDICATED ON THE PLANS AND SPECIFICATIONS OR REQUIRED BY ANY GOVERNvENT AGENCY. 24. UNLESS OTHERWISE INDICATED ON THESE DRAWINGS AS BEING "N.I.C. ", ALL ITEMS, v1ATERIALS, ETC. AND I\ SAME ARE PART OF THE CONTRACT DEFINED BY THESE DRAWINGS. 25. THE BUILDING AND FACILITY IS TO BE ACCESSIBLE TO AND FUNCTIONAL FOR THE PHYSICALLY DISABLED PUBLIC IN ACCORDANCE WITH THE AMERICANS DISABILITIES ACT (ADA) AND ALL OTHER STATE /FEDERAL GOVERNING AGENCIES. 26. THIS PROJECT MEETS THE ADA REQUIREv1ENT 27. PROVIDE FIRE RETARDANT WOOD FIREBLOCKING WITH A v WALLS. AXIv MEP TO BE DESIGN BUILD OWNER WESTFIELD CORPORATION, INC. 11601 WILDHIRE BOULEVARD, 12TH FLOOR LOS ANGELES, CALIFORNIA 90025 T: 206.802.6076 F: 206.246.2856 C: MIKK SEPP E: VSEPP @WESTFIELD.COM ARCH ITECTU RAL DLR GROUP, INC. 900 FOURTH AVENUE, SUITE 700 SEATTLE, WA 98164 T: 206.461 .6000 F: 206.461 .6049 C: JEFF WASSERVIA\ E: JWASSERv1AN @DLRGROUP.COM TSALLATION OF THE UM SPACING OF 10' -0" HORIZONTAL AND VERTICAL IN ALL FRAMED 28. ALL LEGAL EXITS SHOWN ON THE PLAN SHALL BE OPERABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ANY SPECIAL LOCKING DEVICE SHALL BE OF APPROVED TYPE. FLUSH BOLTS ARE NOT ALLOWED. MAXIv1UM EFFORT TO OPERATE EXIT DOORS SHALL NOT EXCEED 8.5 LBS FOR EXTERIOR DOORS. 5 LBS FOR INTERIOR DOORS AND 15 LBS FOR FIRE RATED DOORS. 29. FIRE SAFETY DURING CONSTRUCTION, ALTERATION OR DEMOLITION SHALL COMPLY WITH ARTICLE 87 OF THE UNIFOR BUILDING CODE. PROJECT SUMMARY PROJECT TEAM vl NFPA RATE PERMIT REQUIRED FOR: 'Mechanical ��lectrical Cr Plumbing to Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made tot scope of work without prior app o Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. X08- 375 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 20 8 Of Tukwila BUILDING DIVISION FILE COPY Permit No. Piar review approval is subject to errors and omissions. Approval of construction documents does not the violation of any adopted code or ordinance. Receipt of approved Field Copy and con' , t . wledged: By Date: City of Tukwila BUILDING DIVISION RECEIVED JUL 1 52008 PERMIT GENIE!' (, X I-11 0 Z m F- (19) w cn w 2 J CI) 0 D Et Q W Z w = Ct �n = w D oO U (n 0 0 e L 0 •L a) 0) c c co 0 0) - L a) 0) w 31 A2.1 3/8" THREADED ROD, TIE TO EXISTING STRUCTURE. PROVIDE NUT AND 3 "0 SUPPORT PLATE TYP. EQUALLY SPACED LOCATIONS PER CLOUD, PAINT BLACK STEEL BACK PLATE GYPSUM BOARD CONSTRUCTION OVER METAL FRAMING © 24" O.C., MIN. FINISHED EDGE HORIZONTAL STUDS ® EACH VERTICAL STUD, TOP AND BOTTOM SOFFIT EL = 15' -9 "AFF CORNER /EDGE TRIM OR EQUAL © ALL CORNERS, TYP. 16GA MIN STUD BLOCK BTWN HORIZONTAL STUDS © PLATE 11 A2.1 21 A2.1 RECESSED LIGHT FIXTURE SOUND ATTENUATION BATTS BETWEEN STUDS YPSUM BOARD (PAINT) OVER 3 %" METAL FRAMING ® 16" O.C. 8" MTL STUD FRAMING TO EXISTING STRUCTURE, PROVIDE LATERAL SUPPORT © 24" OC PROVIDE POCKET NOTCH FOR GLASS AT CEILING PER MANUFACTURER'S RECOMMENDATIONS STAINLESS STEEL GLASS PANEL CLIPS WITH 1Y" DIA STAINLESS STEEL FINISH HANDRAIL ATTACHMENT I- tali "CLOUD" DETAIL SCALE: 1 1/2" = 1'--0" TEMPERED GLASS WINDOW SYSTEM BASE RAIL SUSPENDED GYPSUM BOARD CEILING SYSTEM, (PAINT) EVENT SPACE SCALE: 3/4" = 1' -0" SCALE: 3" = 1' -0" BTM OF STEEL EL = 23' -9" CLNG GRID SYSTEM EL = 20' -5" BTM OF CLOUDS EL = 15' -9" SCALE: 1/4" = 1' -0" SOFFIT DETAIL NOTE: COORDINATE WITH MALL EXPANSION SOFFIT AND CEILING RECESSED LIGHT FIXTURE TIE FRAMING TO EXISTING STRUCTURE AS REQUIRED CORNER /EDGE TRIM OR EQUAL ® ALL CORNERS, TYP. TEMPERED GLASS DOOR WINDOW BASE DETAIL INTERIOR ELEVATION REFER TO 32/A2.1 NON- ILLUMINATED SIGNAGE rZ ---- • ON BASE PLATE PROVIDED BY MALL OWNER OR TENANT - PROVIDE POWER FOR FUTURE GRAPHIC 0' -O" UPLIGHTING COVE FIXTURE FINISHED EDGE TOP OF SIGN BAND EL. = 12' -0" AFF FIN SOFFIT EL. = 10' -0" AFF CO PROVIDE WOOD BLOCKING AS REQUIRED CEILING /SOFFIT \______SEE RCP O GYPSUM BOARD CEILING FIN FLOOR \ / I REFLECTED CEILING PLAN SCALE: 1/8" = 1' -0" \ / 1. /' //, / /i/ : //, /// /ii / / / J / / �- -- -'...7 / J EQ EQ 0 / / / . / / / / // / / / // / / , \\ / \\ / / / / / / / / / / / , / / BTM OF STEEL EL. = 16' -7" BTM OF SOFFIT EL. = 12' -0" TOP OF GLASS EL. = 10' -0" 10 FINISH FLOOR EL. = 0' -0" C 27 m N 0 SCALE: 1/4" = 1' -0" / SCALE: 1/4" = 1' -0" NOTE: COORDINATE WITH MALL EXPANSION SOFFIT AND CEILING / EN'AN /T LOGO / / / INTERIOR ELEVATION , �-� INTERIOR ELEVATION // Wesifleki V / / i \ \/ / / / I r 24' -8" (TBD) / / / / / , S I G N A G E L O C A T I O N NOTE: COORDINATE WITH MALL EXPANSION SOFFIT AND CEILING BTM OF SOFFIT EL. = 12' -0" FINISH FLOOR EL. = 0' -0" TOP OF CLNG EL. = 15 -0" FINISH FLOOR EL. = 0' -0" BTM OF CANOPY /PORTALO EL. -- 10 -6" SCALE: NTS / / / / / / / / \ / / / / / 4' -0" \ \ \ 7'' 7" 0' '0 / / 4' -0" \ / / / / / GLASS DOOR ELEVATION PIVOT HINGE CLEAR TEMPERED GLASS DOORS MALL STANDARD 36" OR 48" TUBULAR HANDLES PROVIDE SPEC FOR L.L. APPROVAL 4" HIGH STAINLESS STEE BASE TO MATCH (GLAZING BASE). PROVIDE SLEEVE FOR LOCK BOLT. 0 O NEW 3'- 0 "x7' -0" WOOD DOOR AND FRAME MOUNTED FLUSH WITH INTERIOR FACE OF WALL. PROVIDE ADA APPROVED LEVER HARDWARE. O NEW PAIR 4' -0 "X10' -O" CLEAR TEMP FRAMELESS GLASS DOORS. STAINLESS STEEL HARDWARE AND TRIM. REFER TO 55/A2.1. 0 NOT USED O EXISTING CONCRETE FLOOR TO BE STAINED. COLOR TBD. PRICE AS ALTERNATE: WOOD FLOOR FINISH. O O O KEY NOTES RELOCATED DOOR AND FRAME EXISTING DOORS TO REMAIN NEW STAINLESS STEEL HANDRAIL EXISTING COLUMNS TO REMAIN AND ENCLOSED WITH METAL STUD AND GYPSUM WALL BOARD FINISH O EXISTING ROOF DRAIN AT THIS LOCATION TO REMAIN 0 NEW CLEAR TEMPERED GLASS SET IN 4" STAINLESS STEEL BASE WITH 1/2" BUTT JOINTS 0 EXISTING TO REMAIN 12 INFILL DEMO'D DOOR OPENING TO MATCH ADJACENT SURROUND WALL, PAINT TO MATCH 13 INSTALL NEW COMMUNICATIONS /ELECTRICAL /DATA POWER BOX e EXISTING TUBE STEEL COLUMN TO REMAIN 1' -0" HIGH NEW ENTRY CANOPY /PORTAL 16 PROVIDE TRANSITION STRIP AT FLOOR FINISH CHANGE 17 PROJECTION WALL AREA. PROVIDE LEVEL 4 PAINT FINISH. NO EXPOSED CONDUIT IN THIS AREA, 18 1 "X4" WOOD BASE PAINTED, TYP FOR BASES 19 NEW LIGHT BOX COLUMN FOR GRAPHIC ELEMENT BY OWNER. REMOVABLE PANEL FOR ACCESS AND ELECTRICAL JUNCTION BOX FOR POWER 20 NEW GYPSUM BOARD CEILING AT THIS AREA ® 12' -0" AFF, PAINT WHITE 21 OPEN TO STRUCTURE ABOVE. PAINT UNDERSIDE OF DECK AND JOIST BLACK 22 4'- 0 "X4' -0" METAL CEILING GRID SYSTEM, PAINTED BLACK UNISTRUT P2000 - BASIS OF DESIGN 23 GYPSUM BOARD CEILING "CLOUD" WITH RECESSED CEILING CANS © 15' -9" AFF, PAINT WHITE 24 EXPOSED HVAC DUCTWORK, PAINT BLACK 25 GYPSUM BOARD SOFFIT © THIS AREA © 10' -0" AFF, PAINT WHITE. SEE DETAIL 21/A2.1. 26 HOLLOW METAL DOOR AND FRAME - PAINT TO MATCH ADJACENT SURFACE /WALLS 27 ETCHED VINYL LOGO APPLIED TO INSIDE GLAZING SURFACE, PROVIDED BY TENANT OR MALL MANAGEMENT 28 LOW PROFILE RECESSED CAN LIGHT FIXTURES - PAR LAMPS 29 QUAD ELECTRICAL RECEPTACLE MOUNTED TO BACK SIDE OF STEEL COLUMN LEGEND I ci F® EXISTING TO REMAIN NEW CONSTRUCTION DUPLEX OUTLET TELEPHONE OUTLET DATA EMERGENCY STROBE LIGHT /HORN © 84 "AFF EXIT LIGHT ROOM FINISH NOTES 1. ALL NEW INTERIOR WALL TO BE PAINTED WHITE (LEVEL 4) FINISH. RCP GENERAL NOTES 1. RUN /ATTACH ELECTRICAL CONDUIT, PAINTED BLACK AT TOP OF EACH GRID ABOVE "CLOUD ". INSTALL QUAD RECEPTACLE ON TOP OF EACH "CLOUD" RCP LEGEND O RECESSED CAN LIGHTS MECHANICAL DIFFUSERS ELECTRIC- ROLL DOWN BLIND SYSTEM - BLIND "ROLL" BOXES TO BE ATTACHED TO BACK OF HORIZONTAL MULLIONS OF WINDOW SYSTEMS. BOTTOM OF BLIND ROLL IS FLUSH WITH BOTTOM OF MULLION SYSTEM. 1yo 8 -37s RECEIVED JUL 1 5 2008 PERMIT CENTER J F W co D CO (i) Z Q Q (i) 0 Z � O Lil Q ~ > Z w W � U w = Q = J 0 d fn W `0 Cle: U N c L . 0 IINIMINI U CC 1::::) U o L o N 0 L O U 15 a ED CL •L U