Loading...
HomeMy WebLinkAboutPermit D08-388 - RESIDENCE INN - STORAGE SHEDRESIDENCE IIoTN 16201 WEST VALLEY HY D08 -388 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: 0005800006 16201 WEST VALLEY HY TUKW RESIDENCE INN 16201 WEST VALLEY HY , TUKVVILA WA GRAND PRIX TUKWILA LLC C/O HEMA GANDHI , 340 ROYAL POINCIANA WAY #306 33434 Contact Person: Name: TERRY CAMPBELL Address: 17500 WEST VALLEY HY , TUKWILA WA 98188 Phone: 425 - 251 -8833 Contractor: Name: TUFF SHED INC Address: 8939 SOUTH 190TH STREET, #D , KENT, WA 98031 Phone: Contractor License No: TUFFSI *038RZ DESCRIPTION OF WORK: BUILD 240 SQ FT DETACHED STORAGE SHED Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 V -B City' Tukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us $8,858.40 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Expiration Date: 07/02/2009 Fees Collected: International Building Code Edition: Occupancy per IBC: D08 -388 08/18/2008 02/14/2009 $358.43 2006 26 D08 -388 Printed: 08-18 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature I hereby certify that I have read and governing this work will be complie The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the he performance of work. I am authorized to sign and obtain this development permit. i Signature: Print Name: doc: 18C -10/06 City oPTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D08 -388 Issue Date: 08/18/2008 Permit Expires On: 02/14/2009 Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. Date: V OR This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -388 Printed: 08 -18 -2008 • City of Tukwila Parcel No.: 0005800006 Address: 16201 WEST VALLEY HY TUKW Suite No: Tenant: RESIDENCE INN 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: D08 - 388 Status: ISSUED Applied Date: 07/30/2008 Issue Date: 08/18/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Thkwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** D08 -388 Printed: 08 -18 -2008 doc: Cond -10/06 • City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: 1 1 2 -1 2 — e--4M P a Date: D08 -388 Printed: 08 -18 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:!i,tiriv.ci trrttitirila. Property Owners Name: (LpN'b. P '(L\ x. 1 t.t.) A L P L IBC. Mailing Address: Sc►y-\F Name: Mailing Address: 1'7 S O k1J --E- \ V E -Mail Address: 1 t .v-AQ iSEU- q, -- OF 5rS ■aeD • cc wl Company Name: Mailing Address: "Tv FF -St-\80O tr)c. 1,I A O a Contact Person: T (..p-'W Y L1i� E -Mail Address: T L -e --WF LL _— uF -S \> -C .GotM Contractor Registration Number: TV FFS T,-O'3 YLZ Contact Person: E -Mail Address: Q Apphcanons\Fonns- Appluanons On L11163-2006 - Permit Apphcation.doc Revised 9-2006 bh Building Permit No. 30 - 8 Mechanical Permit No. Plumb ing /Gas. Permit No. Public. Works Permit No. Project No. (Fo office use Only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATIO King Co Assessor's Tax No.: 00 0'S% 0000 Co Site Address: L 0 \ W eST V p t: / 1 Wu Suite Number: Tenant Name: (Z. S t t) C, I N 1J / " -0 NI City New Tenant: El State CONTACT PERSON;'--: who do:we contact when your permit is ready to be issued; • Day Telephone: A-VS - 7i' \ O - % a \ 8 k gS cS City State Zip Fax Number: /1/4-1-6- - ZS \ - c -1 of S GENERAL CONTRACTOR INFORMATION' - (Contractor Information for Mecha'nical.(pg 4) for Plumbing and Gas Piping (pg 5)) ' City State Floor: Yes ❑..No Zip Zip Day Telephone: A-2 5- ' \ - c633 Fax Number: 1 1 - ? 5 0 1 5 Expiration Date: - Z.- C) �( ARCHITECT OF RECORD; = Atl'plans must be wet stamped •by Architect:of Record Company Name: Mailing Address: city Day Telephone: Fax Number: State Zip ENGINEER OF All planslmu be wet stamp e d'liy Engiiieer of Record { e 4. • Company Name: M t ,C 1 >1■3 sJ \ S S Mailing Address: 1‘,1( > -) SST v & 'b • L. 14;) V"l \ S S Ou \ 6" 13 \ Contact Person: C t .) � 1 1.1 t•-) E -Mail Address: Fax Number: City State Zip Day Telephone: 3 \ ' 4-b 9 - G4-60 Page 1 of 6 BUILDING PERMIT INFORMATION - 206 =431 -3670 Valuation of Project (contractor's bid price): $ ( 5 -.. 43 O Scope of Work (please provide detailed information): 1c� •A ED Sk b Will there be new rack storage? ❑ Yes 0 Provide All Building Areas in Square Footage Below _ , PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. .Q: ApplicationsToems- Apphcaboms On Lme'3 -2006 - Permit Apphcabon.doc Revised: 9 -2006 bh Existing Building Valuation: $ �SSC�C If yes, a separate permit and plan submittal will be required. Page 2 of 6 Existing ' Interior Remodel Addition to' Existing. _ • Structure? / '. New : .' -Type of Construction per • IBC - * . , Type'of ' : , Occupancy per: ' °' „' IBC G 1 '2", -0:4•. .i• 4'. - _ , 3;d`Floor;', . Floors'z , . - `fhru_ : ', Basements : ,,;i; ` . Accessory: Structure«''. - P, 0 ':Attached - Garage „ Detached°Garage ': ,Attached -Detached'Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 =431 -3670 Valuation of Project (contractor's bid price): $ ( 5 -.. 43 O Scope of Work (please provide detailed information): 1c� •A ED Sk b Will there be new rack storage? ❑ Yes 0 Provide All Building Areas in Square Footage Below _ , PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If 'yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. .Q: ApplicationsToems- Apphcaboms On Lme'3 -2006 - Permit Apphcabon.doc Revised: 9 -2006 bh Existing Building Valuation: $ �SSC�C If yes, a separate permit and plan submittal will be required. Page 2 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTBOrlIZED AGENT: Signature: ` � Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Mailing Address: ` 5 00 '- - v Pu -Y 'W`l Q:\Applications\Fonns- Applications On Line \I-2006 - Permit Applicationdoc Revised: 9 -2006 bh Date: g Day Telephone: .4-25- - 2- 4- 5 - 1 Fs 33 City State Zip Date Application Accepted: Date Application Expires: 1 -3U -d9 Staff Initials: Page 6 of 6 Parcel No.: 0005800006 Permit Number: D08 -388 Address: 16201 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 07/30/2008 Applicant: RESISDENCE INN Issue Date: Receipt No.: R08 -02784 Initials: WER User ID: 1655 Payee: ANTHONY TRENTACOST ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1013 358.43 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $358.43 Payment Date: 07/30/2008 11:13 AM Balance: $0.00 214.50 139.43 4.50 Total: $358.43 5462 07/30 9710 TOTAL 358.43 doc: Receipt -06 Printed: 07 -30 -2008 COMMENTS: Type of Insio4tion: f ,,ii4 :: O 6TI "-I Rt) (if ?L P4 L) M A / 692a/ /V / k e�'K"( ' 1 A I-1 AA, A , 6 ee.i. 1\-\ N J P-70 t, 4 i\ Ie 9. i : �J` 64A 1� ` :� (AV uk A 1 q� ) p.m. Requester: Phone No: ) Lj C-0 p pi cei ii.r Art.- d Proj ct: / es tefeet mac% Type of Insio4tion: f ,,ii4 A / 692a/ /V / Date Called: Special Instructions: Date Wanted: 3 / ' c G 7 p.m. Requester: Phone No: J;tzf INSPECTION NO. INSPECTION RECORD Retain a copy with permit D4f- .8 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspector i Date:3 — D7 $60.00 REINSPECTIbN FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Prod j°/l -rt/( J\1 Type of spection:- F/2 7/41 A /r/ ���s /4 Date Called: Special Instructions: Date Wanted: _ Q /6 - 6. C_..i � a a� m. Requester: Phone No: C OM A� t €NTS: \ : j ) 51) A WI r te.? 4, _App✓oveL L r R.e. 6246^ (.4 ( h4(f c (4 Fr V ill ; -1 - 11 r V 'Q- ` Inspecto Jam_ Date: f '' ..• INSPECTION RECORD Retain a copy with permit INSPECTION NO. } PERMIT NO. CITY OF TUKWILA BUILDING DIVISION & 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3(6 pproved per applicable codes. Corrections required prior to approval. NSPECTION FEE f MIRED Prior to inspection, fee must be p d at • 300 Southcenter Blvd., Suite O. Call to schedule reinspection. Receip o.: !Date: Project: 1Ze : S: )'cAt -L LFuA) Type of Inspection: 1/4e1 • J,k)/l( 5k f- t`" v( /f Address: (1 ZD ( /A) : 1 t .-. Date Called: ` Special Instructions: D e Wanted: a J 0 3 Off p.m. Requester: Phone No: s — z.5 r - - A T,3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector( Date: to- 3 , J / EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: -A e S . Jest 4.E SU/� Type of Inspection: {I 06 F' Stt.e .` V Address: / f (, 7,0 ( Li v Alfa -t^ 7 Date Called: Special Instructions: • ye Wanted: v .. 3 - °� �a�,. p.m. Requester: Phone No: S— — Z S / — 33 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. D Corrections required prior to approval. �Z COMMENTS: Inspe for: (� :3. Lk Dater 3 , )r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Protect: S . , r a / Type of p ect( i vi Address* /0. w - Date Called: ; Special Instructions: { Dat Wanted: (2, L a.m� 0 p.m. Requester: r Phone O G ; I7 (-3 `4 '�A 1r INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • t- . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 '(206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: • J { Ins ector \ LvW • Date: z or / El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Q Ol Nipw a � Gp' �SZOi n` `OWN DESIGN LOADS: TOP CHORD LIVE LOAD = 40 PSF TOP CHORD DEAD LOAD = 10 PSF TOP CHORD LATERAL LOAD = 35 PSF MEMBER FORCES: 1 - 2 1300 Ibs 2 - 3 1300 Ibs r ;- D08- 388 NOTES: 1997 UBC, 2003 IBC, 2006 IBC, 2007, CBC TRUSSES TO BE SPACED @ 24" OC MATERIAL TO BE 2X4 HEM -FIR GRADE #2 OR BETTER Drawn By: JSA Date Drawn:10 /9/2007 Checked By: FILE COPY Permit No. 5' -0" 1/4" =1 5 ;415 NOTE: TRUSS MAY BE USED ON BUILDING LENGTHS UP TO 20FT UNLESS CEILING JOIST OR OTHER TENSION TIE IS PROVIDED 3X4 20 GA PLATES 1 EACH SIDE 1 6 " RECEIVED JUL 3.0 2008 PERMIT CENTEF Date Revised: Scale: 1/4" = 1-0" ®Title: FRAMING DETAIL TUFF SHEll 10' RANCH PRO SHED TRUSS Storage Buildings & Garages Jeff Austin 15425 1 McGinnis and Associates ; 10 Foot Ranch Truss Oct 9, 2007 at 2:41 PM 1 3d View of 10'x20' Ranch Pro Rafters w/ 1/2" Sheathing 1OftRanchPro_24.r3d Loads: LC 1, Gravity McGinnis and Associates Jeff Austin 15425 10 Foot Ranch Truss Gravity Loads: 10psf DL + 40psf LL (equiv. area) 1 i Oct 9, 2007 at 2:43 PM 1 10ftRanchPro_24.r3d • Y .X Member Code Checks Displayed Results for LC 1, Gravity McGinnis and Associates Jeff Austin 10 Foot Ranch Truss 15425 I Unity Check of Worst Case Rafter Under Gravity Loads 1 oftRanchPro_24.r3d Code Check _ No Catc >1.0 90-1 0 .75 -.90 .50 -.75 0:.50 Oct 9, 2007 at 2:45 PM - .018k/ft .245 1i127k /ft_. Loads: LC 2, Wind McGinnis and Associates Jeff Austin 15425 - .018k/ft 10 Foot Ranch Truss Oct 9, 2007 at 2:43 PM Lateral Loads: 10psf DL + 35psf WL (equiv. area) 1oftRanchPro_24.r3d .Y Member Code Checks Displayed Results for LC 2, Wind McGinnis and Associates Jeff Austin 15425 10 Foot Ranch Truss Unity Check of Worst Case Rafter Under Lateral Loads 10ftRanchPro_24.r3d Oct 9, 2007 at 2:46 PM Code Check No Calc > 1.0 .90 -1.0 .75 -.90 .50 -.75 0. -.50 Roof Load Summary Roof Support: Trusses @ 24 in. c/c Truss Span (ft): 10 Roof Dead Load (psf): 10 Roof Live Load (psf): 30 Roof Snow Load (psf): 30.00 Governing Total Load (psf): 40 See Calculations to Follow I McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 FILE COPY JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 1 OF 13 CALC. BY CJD DATE 7/22/2008 Structural Calculat for: Residence Inn Tuff Shed Project No. 170 - 561964 Building Dimensions: Overall Building Width: Overall Building Length: Building Overhangs: Consider Vertical Dead Loads: Live Loads: Snow Loads: REVIEWED FOR ;ODE COMPLIANCE APPROVED AUG 14 2008 I .'4 p r J �_yt � �6 f S1!7 0_561964 Of Tukwila Plate Heights: Loads: Roof Dead Load: Wall Dead Load: Roof Pitches: Peak Roof Height Mean Building Height: Roof Live Load: Roof Snow Load: IB := 101 IL := 241 (Boyer 6in Finished Floor Elevation: Top of Plate Elevation: Roof Angle: 4 pitch := 12 — Project Location: Building Code: Tukwila, WA 2006 IBC hpeak 10ft + 3 2 in IDLroof IOps1l f DLwall 8 ps1 (LLroof = 30 psI ISLroof 30psfi Roof End Reactions: tX* 388 (nb. ridge runs parallel to Length) I I-over 6 in hfloori 6ir hfloor 8ft + Oirj O := atan(pitch) hmean (hfloor + hpeak) IRroof_DL = 110 lb I IRroof_LL = 330 lb I hplate hfloor IO = 18.43 degl Ihmean = 9.15 ft Dead Load: Rroof DL CB + Bove) DLroofrtspacing " SL Total Load: Rroof LL I B + Bove 1 max roof rtspacing \ LLroof)) RECEIVED JUL 3 0 2008 PERMIT CENTER Concentrated Load Data Number DL (kips) LL (kips) a dist. (ft) Description P1 0.00 0.00 0.00 0.06 P2 0.00 0.00 0.00 w2 P3 0.00 0.00 0.00 0.00 P4 0.00 0.00 0.00 0.00 P5 0.00 0.00 0.00 0.00 P6 0.00 0.00 0.00 Uniform Load Data Number DL (kip/ft) LL (kip/ft) a dist. (ft) c dist. (ft) trib. wt. (ft) Description w1 0.02 0.06 0.00 0.00 2.00 Roof Load w2 0.00 0.00 0.00 0.00 0.00 Max Live Load Deflection (in) w3 0.00 0.00 0.00 0.00 0.00 3207 w4 0.00 0.00 0.00 0.00 0.00 w5 0.00 0.00 0.00 0.00 0.00 w6 0.00 0.00 0.00 0.00 0.00 Shears, Moments, & Deflections Maximum Shear Stress (psi) Commercial Grade 18 # of Mem. Allowable Shear Stress (psi) d 173 OK MaAamum Bending Stress (psi) E 189 (in) Allowable Bending Stress (psi) (in) 975 OK Max Dead Load Deflection (in) No.2 0.003 10655 Max Live Load Deflection (in) 3.5 0.008 4587 Max Tatal peflection (in) 1300 0.011 3207 . > . _iib • • USE 2 - 2x4 Selected Member Properties Species Commercial Grade Member Size # of Mem. b d Area S I E (in) (in) (in (in) (in) (ksi) Hem - Fir No.2 2x4 2 1.5 3.5 10.50 6.13 10.72 1300 Reactions Beam Design Data Member: TL (kips) 2x4 Beam Span (ft): 3 # of Memb: Right End 2 0.09 Unbraced Length (ft): 3 Adjustment Factors - NDS Table 2.3.1 C0 CM Ct CL Ci C 1.15 1.00 1.00 See Below 1.00 1.00 Reactions DL (kips) LL (kips) TL (kips) Left End 0.04 0.09 0.13 Right End 0.04 0.09 0.13 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 2 OF 13 CALC. BY CJD DATE 7/22/2008 3 Foot Opening Header 'Calculated Adjustment Factor I C I0.9977I Effective Length Factor k E. 1.84 (Ref NDS Table 3.3.3) L := k • L L = 5.52 ft P L L W 11,1111iiI L R I P: \O_PR OJ E CTS\ 1600M16300 16322TS 170_561964 Concentrated Load Data Number DL (kips) LL (kips) a dist. (ft) Description P1 0.00 0.00 0.00 0.17 P2 0.00 0.00 0.00 w2 P3 0.00 0.00 0.00 0.00 P4 0.00 0.00 0.00 0.00 P5 0.00 0.00 0.00 0.00 P6 0.00 0.00 0.00 Uniform Load Data Number DL (kip/ft) LL (kip/ft) a dist. (ft) c dist. (ft) trib. wt. (ft) Description w1 0.06 0.17 0.00 0.00 5.50 Roof Load w2 0.00 0.00 0.00 0.00 0.00 278 w3 0.00 0.00 0.00 0.00 0.00 w4 0.00 0.00 0.00 0.00 0.00 w5 0.00 0.00 0.00 0.00 0.00 w6 0.00 0.00 0.00 0.00 0.00 Shears, Moments, & Deflections Maximum Shear Stress (psi) 83 Member Size Allowable Shear Stress (psi) 328 OK Maximum Bending Stress (psi) 1,649 I,, Allowable Bending Stress (psi) 3,184 OK Max Dead Load Deflection (in) 0.153 943 Max Live Load Deflection (in) 0.365 395 Max Total Load Deflection (in) 0.517 278 USE 2 - 1.75x7.25LVL Selected Member Properties Species Commercial Grade Member Size # of Mem. b d Area S. I,, E (in) (in) (in (in (in (ksi) Microllam LVL N/A 1.75x7.25LVL 2 1.75 725 25.38 30.66 111.15 1900 Beam Design Data Member: 1.75x7.25LVL Beam Span (ft): 12 # of Memb: 2 Unbraced Length (ft): 2 Adjustment Factors - NDS Table 2.3.1 CD CM C, CL C; C 1.15 1.00 1.00 See Below 1.00 1.00 Reactions DL (kips) LL (kips) TL (kips) Left End 0.41 0.99 1.40 Right End 0.41 0.99 1.40 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 3 OF 13 CALC. BY CJD DATE 7/22/2008 12 Foot Opening Header (Calculated Adjustment Factor I C 1 0.9945 I Effective Length Factor: k = 1.84 (Ref NDS Table 3.3.3) L := k•L L = 3.68 ft R r Trchr R P L �n w b II L P: \O_PROJECTS \16000 \16300 \16322 TS170 561964 Main Windforce Resisting System Loads: p. (ASCE 7 Figure 6 -2) Horizontal Loads (psf) Vertical Loads (psf) Interior Zone: Wall Roof Interior Zone: Windward Roof Leeward Roof Transverse 10.3 -2.4 Transverse -9.6 -7.2 Longitudinal 7.6 -3.5 Longitudinal -9.6 -6.1 Calculated Wind Loads Horizontal Loads (psf) Vertical Loads (psf) Interior Zone: Wall Roof Interior Zone: Windward Roof Leeward Roof Transverse 12.4 10.0 Transverse -11.6 -8.7 Longitudinal 10.0 10.0 Longitudinal -11.6 -7.4 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 4 OF 13 CALC. BY CJD DATE 7/22/2008 IBC Lateral Loads Determine Wind Loads: Basic Wind Speed (3 second gust): Wind Load Importance Factor: Exposure Category: Height and Exposure Coefficient Basic Wind Pressures: Project Location: Building Code: Tukwila, WA 2006 IBC Vwind 85mpd I := 1.0 Exposure := "CnI 1, = 1.21 nb. intermediate roof angles are interpolated Calculated Wind Pressures: (10psf minimum wall load, Opsf minimum roof lateral load). Wind Loads Transverse Direction: Trib_arearoof t hpeak — hfloor hplate Trib_areawall t - 2 Transverse wind forces: Wind Loads Longitudinal Direction: IB = 10ftI IB= 10 ft I hplate Trib_areawall_I (hmean — hfloor + 2 Longitudinal wind forces: Force at roof: Fwind I Pwhlw•B•Trib_areawall I Distributed forces at root IL =24ft Trib_arearooft = 2.29 ft Trib_areawall t = 4 ft Force at roof: F wind t PwhtrL- Trib_arearoof t+ P L- Trib_area t IL =24ft I Trib_areawall_I = 5.15 ft Fwind I = 514.58 lb Ihpeak = 10.29 ft Ihmean = 9.15 ft Fdwindl Pwhlw'Trib_areawall I Fdwind I = 51.46 plf Fwind t = 1744.94 lb Distributed forces at roof: Fdwind_t PwhtrTrib_arearoof_t + P Trib_area Fdwind_t = 72.71 plf P10 PROJECTS11 600011 630011 632 2 TS170 561964 MCGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Buildino - PPRS #170 - 561964 NO. 16322 SHEET NO. 5 OF 13 CALC. BY CJD DATE 7/22/2008 Determine Seismic Loads: Seismic Use Group: Max Considered Earthquake Coefficients: Seismic Site Class: Seismic Importance Factor: Site Coefficients: {tables 1615.1.2(1 -2)) Adjusted Max considered Earthquake: Design Spectral Response Acceleration: Structural System: Response Modification Factor: Approximate Fundamental Period: T :_ .020• Seismic Design Category: Determine structural dead load: Ws Floor and Roof Dead Loads: Area of Roof & Floor: Total Roof Dead Load: Exterior Wall Dead Loads Length of wall: Wall Dead Load: Total Structural Dead Load: IR := 6.1 ISDC = " I Wroof shear Use_Group := I IS s := 1.411 I Site_Class := "D "I IIE := 1. 1 IFa -1 I ISms = 1.42 I ISds = Basic_Structural_System := "Bearing Wall System" Seismic_Resisting_System := "Light Framed Walls w/ Wood Shear Panels" {table 1617.6) hpeak I ft ) Ts (Sd1 - Sd •sec Area := (L + 2Lover)•(B + 2Bover) Wroof Area • DLroof IS 1 := 0.485 IF = 1.52 ISm1 = 0.73 I ISd1 = 0.49 IT 0.11 IT 5 = 0.52 s I Sds 1 r Sds 0 . 5 •S1)) Seismic Response Coefficient: C := if S1 < 0.6, max 0.01 , max10.01 , R- IE) R- IE , R- IE)) Si-roof > 30, Area• DLroof+ psf Wall load tri butary to roof: Lwall:= L +B +L +B hmean Wwall shear= DLwall•Lwalt• — Wwall of DLwall Ws_shear Wroof shear + Wwall_shear Ws_ot Wroof + Wwall_ot 2 Area = 275 ft 2 Wroof = 2.75 kip SLroof) 5 ) Wroof ICS = 0.15 Lwall = 68 ft Wwall shear = 2.49 kip Wwall of = 4.98 kip IWs_shear = 5 kip/ IWs_ot = 7.73 kip/ P:\O_PROJECTS\16000\16300\16322_TS170_561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 6 OF 13 CALC. BY CJD DATE 7/22/2008 Determine Total Base Shear Forces: Compare Seismic Forces at Roof: Wind & Seismic Forces: Use Maximum Forces: Roof Diaphragm Design: Controlling Lateral Load: Strut Reaction, R: Uniform Shear in Strut, v: Chord Forces (T = C): Vd Diaphragm Chord /Drag: Area of Chord: Allowable Tension in Chord: Load duration factor: Consider Drag Strut dragspacing FEQ = 0.8 kip FdEQ_t = 31.72 pl1 FdEQ I = 76.12 plf L Rroof Fdroof t' 2 Rroof B Diaphragm and Fasteners Design Strength: Roof deck is 1/2" wood floor sheathing with 8d common nails @6" o.c. at edges. Use 8d common nails @12" o.c. for interior nailing. FEQ Cs'Ws shear FdEQ t FEQ _ L FdEQ I FEQ _ B Froof_t max FEQ , Fwind_t) Fdroof_t max(FdEQ_t, Fdwind_t) (Wind Governs Transverse Load. (Transverse Load Governs Diaphragm Design. Fdroof t'L 2 Tchord 8B Achord 5.25in 2 Ft := 400psi CD := 1.6 Pa Ft'Achord•CD B Rroof _ vfastener Fwind_t = 1.7 kid Fdwind_t = 72.71 p11 IRroof = 872 lb I (vd = 87 plf ITchord = 523 lb Ivallow 197p11 (Since vatiow = 197 lb /ft >= v = 87 lb/ft OK I chord := "Double 2x4 Hem Fir Top Plate" Fastener type: Number of Nails Required: IPa = 3360 lb I Use Double 2x4 Hem Fir Top Plate with 4 - 16d nails each side of splice minimum. 1 Idragspacing = 12.24 in Fwind_I = 0.5 kip Fdwind_I = 51.46 plf Froof I max(FEQ , Fwind_I) Fdroof I max(FdEQ_I, Fdwind_l) (Seismic Governs Longitudinal Load. I v RC)::r ugri w R N 1 Nfasteners -> v fastener := "16d nails" Allowable shear per fastener: vfastener 891b Tchord vfastener CD P :10_PROJ E CTS116000\16300\16322_TS 170_561964 Selected Member Properties Species Commercial Grade Member Size # of Mem. b d Area S. I E (in) (in) (in (in) (in) (ksi) Hem -Fir Stud 2x4 1 1.5 3.5 5.25 3.06 5.36 1200 Adjustment Factors - NDS Table 2.3.1 C M C, CF C, C r CT 1.00 1.00 1.00 1.00 1.15 1.00 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 7 OF 13 CALC. BY CJD DATE 7/22/2008 Consider 2x Wood Studs - Plate Height Iht := hplate - 4.5irl Compression Parallel to Grain Non - Adjusted Design Value: Grading Adjustment Factor: Coefficient Used for Column Stability Factor. Maximum Bending Unbraced Length: Determine the allowable axial compressive stress per NDS Section 3.6 Modified Modulus of Elasticity: Stress used for column stability factor: Column stability factor. Allowable axial compression design stress w/ no lateral load: Maximum Allowable Axial Load w/ no lateral load: Allowable axial compression design stress with lateral load: IL := 12ir1 'Member := "2x4"1 Unbraced Length Factor: IF = 800 psi IKcE 0 . 3 Effective Length Factor: (Ref NDS Table 3.3.3) E':= E -Cm •Ct•Ci• K Ik := 1.t F := 2 kl 1 ddressed (id)) FcE) 1+ — F c Cp 2 •c ICD := 1.15 ICD:= i.1 No of Members: (See NDS Section 3.7.1) (See NDS Section 3.7.1) 1+ 'n := 1 Unbraced Length: kl := k•ht k := 1.84 L := k • L L = 1.84 ft ( FcE) -2 F c •c FcE F C F'c_No_LL Fc•CD•CM•Ct•CF•Ci - Cp Pallow_No_LL A(id)•F'c_No_LL F'c_w_LL := Fc•CD•CM •Ct•CF•Ci•CP E' = 1200000 psi FcE = 526.74 psi Cp = 0.54 Ikl = 7.63 ft ' IF'c_No_LL = 492 psi rallow_No_LL = 2585 lb I IF'c_w_LL = 685 psi P:\0 PROJECTS \16000 \16300 \16322 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 8 OF 13 CALC. BY CJD DATE 7/22/2008 Determine the allowable bending stress per NDS Section 3.3 Determine the slenderness ratio: RB := if > 0•ft, Le •ddressed(id) 1 bdressed (id) Coefficient used for beam stability factor: Tabulated bending design value from Table 4A: Tabulated bending design value multiplied by applicable adjustment factors: Beam stability factor: Allowable bending stress: Lateral pressure: Maximum moment due to lateral pressure: Maximum bending stress: Find the maximum compressive stress to satisfy the bending and axial compression interaction equation. Solving for the compressive stress results in: Maximum allowable axial load w/ lateral load: Controlling allowable axial load: Required axial load capacity: Stud deflection @ midheight: KbE := 0.439 Fb material = 675 psi Fbstar Fb material CL := i Mmax fb := Sx(id) Ifc = 284 psi Prequired lateral L > 0•ft, Pwhtw = 12.45 psi Pallow_w_LL A(id) f Fallow = 1490 lb I Stress value used for beam stability factor: FbE 1+ Fbstar) 1.9 Fb_allow Fb_material•CM•Ct•Ci Mmax Pwhtw twidth•ht fc 1 F c 5 Pwhtw 4 384.E-1 RB = 5.86 Tributary width of member: Rroof DL + . LL rtspacing _ twidth Mmax fb = 473 psi fb Fb allow• FbE FbE 1+ Fbstar) Fbstar , 1.0 1.9 0.95 = 121 lb-ft 1— FcE) fc IPallow_w_LL = 1490 lb I Alateral = 0.2 in KbE • E FbE := 2 FbE = 15.34 ksi RB IFb_allow = 1237 psi I Itwidth 16in CL= 1 5. 1.0 (NDS equation 3.9-3) Axial load w/ lateral load governs Prequired = 183.33 lb ht — 466 A lateral P' \0 PROJECTS116000\1630011 63 2 2 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Buildino - PPRS #170 - 561964 NO. 16322 SHEET NO. 9 OF 13 CALC. BY CJD DATE 7/22/2008 Shear Wall Design: Consider Wall A: Percentage of lateral force taken by wall A: Total Panel Length: Shear Length: Shear Stress: Fastener type (penny weight): Fastener spacing at edge: Hem -Fir Studs Used? Use wind increase? Sheathing Applied Directly? Adjustment for perforated shearwall: Check Uplift: Overturning Moment: Roof Tributary Area: Resisting Moment: Tension Required: Ilwall 6f� I lshearwall 61 vv1 Froof t•Percent At := 2f1 Ishearwall nail_size := 8 edge_spacing := 6in HF_reduction := "yes" {18% reduction if hem -fir studs are used) wind_increase := "no" direct_applied := "yes" Imax_height_opening := Ofl Iperforated_multiplier = 1.00 For 0.469 in. Wood Structural Panel applied directly to framing w/ 8d nails @ 6 in. edge spacing. 'Since v„ = 145 lb /ft <= va1Iow = 230 lb /ft OK I Mot Froof t Percent •hplate 2 2 'wall 'wall 31 wall ' wall 2 Mres DLroof 2 + Pwvti 8 + Pew 8 ) At + DLwall 2 hmean 'Since M res 1.3 k -ft < Mot 7.0 k -ft Uplift. Check tension. tension :_ Mot — Mres ( wall — 6in (Froof t = 1744.94 lb (Percent := 50 %1 vv1 = 145.41 plf Sheathing grade: Sheathing thickness: M = 6.98 kip-ft Mres= 1.29 kip•ft 'Wind Governs Transverse Load. sheathing := "Wood Structural Panel" 15 thickness := — in 32 {40% allowable increase permitted per 2306.4.1) {Per IBC Table 2305.3.7.2) Ivallow = 230 pit 21 tension = 1035.37 lb (Since Tension 1035.4 lb > 750.0 lb Use Simpson PHDTs. I P: \O_PROJECTS \16000 \16300 \16322 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 10 OF 13 CALC. BY CJD DATE 7/22/2008 Shear Wall Design: Consider Wall C: Percentage of lateral force taken by wall C: Total Panel Length: Shear Length: Froof 2.Percent Shear Stress: v := v = 87.25 plf Ishearwall Fastener type (penny weight): nail_size := 8 Fastener spacing at edge: Hem -Fir Studs Used? Use wind increase? wind increase :_ "no" Sheathing Applied Directly? Adjustment for perforated shearwall: For 0.469 in. Wood Structural Panel applied directly to framing w/ 8d nails @ 6 in. edge spacing. Check Uplift: Overturning Moment: Mot Froof_t•Percent•hplate Roof Tributary Area: Resisting Moment: Tension Required: Ilwall I Off l lshearwall loft IAt:= 2ft Mres edge_spacing := 6in HF_reduction := "yes" {18% reduction if hem -fir studs are used) direct_applied := "yes" IFroof t = 1744.94 lb [Percent := 50 ° /d Sheathing grade: 'max_height_opening := Of1 Iperforated_multiplier = 1.00 Since v„ = 87 lb/ft <= vauow = 230 lb /ft OK I 21 2 ( wall 'wall 3 lw all 'wall DLroof + PSI + Pte, • 8 At + DLwall 2 hmean 2 2 2 8 ■ Mot – Mres tension :_ 'wall – 6in Sheathing thickness: M = 6.98 kip .ft 'Wind Governs Transverse Load. Mres = 3.57kip'ft tension = 358.91 lb sheathing := "Wood Structural Panel" 15 thickness := —in in {40% allowable increase permitted per 2306.4.1) {Per IBC Table 2305.3.7.2) Ivallow = 230 pl! 'Since Mres 3.6 k -ft < M = 7.0 k -ft Uplift. Check tension. 'Since Tension 358.9 lb <= 750.0 lb Sill Plate will Suffice. P:\O 60 0 011 630011 6 3 22 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 11 OF 13 CALC. BY CJD DATE 7/22/2008 Shear Wall Design: Consider Wall B: Percentage of lateral force taken by wall B: Total Panel Length: Shear Length: Shear Stress: Ilwall 6ft vv1 Fastener type (penny weight): Fastener spacing at edge: Hem -Fir Studs Used? Use wind increase? Sheathing Applied Directly? Adjustment for perforated shearwall: Check Uplift: Overturning Moment: Roof Tributary Area: Resisting Moment: Tension Required: I 'shearwall 61 Froof J.Percent tension :— Ishearwall nail_size := 8 edge_spacing := 6in HF_reduction := "yes" wind_increase := "no" direct_applied := "yes" I At := 5ft + 6irl (Froof I = 761.21 lb 'Percent := 25 %I v = 31.72 plf 'max_height_opening := 0fi) Iperforated_multiplier = 1.00 I For 0.469 in. Wood Structural Panel applied directly to framing w/ 8d nails @ 6 in. edge spacing. (Since v = 32 lb/ft <= va1Iow = 230 lb /ft OK I Mot Froof J.Percent •hplate 2 2 21 2 wall 'wall i 31 wall 'wall Mres DLroof 2 + Pwvll 8 + Pwvlw 8 ) At + DLw 2 hplate 'Since Mres 1.1 k -ft < M 1.5 k -ft Uplift. Check tension. I Mot - Mres 'wall — 6in M = 1.52 kip .ft Mres= 1.1 kip•ft Seismic Governs Longitudinal Load. 1 {Note: 2 - 6' panels each resist 25% of lateral force = 50% total} Sheathing grade: sheathing := "Wood Structural Panel" Sheathing thickness: thickness := 55 in 32 {18% reduction if hem -fir studs are used} {40% allowable increase permitted per 2306.4.1} tension = 77.38 lb {Per IBC Table 2305.3.7.2} Ivallow = 230 pIt (Since Tension 77.4 lb <= 750.0 lb Sill Plate will Suffice. P: 10 PROJECTS116000 \16300 \16322 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 12 OF 13 CALC. BY CJD DATE 7/22/2008 Shear Wall Design: Consider Wall D: Percentage of lateral force taken by wall D: Total Panel Length: Shear Length: Shear Stress: Fastener type (penny weight): Fastener spacing at edge: Hem -Fir Studs Used? Use wind increase? Sheathing Applied Directly? Adjustment for perforated shearwall: Check Uplift: Overturning Moment: Roof Tributary Area: Resisting Moment: Ilwall 24fi Ilshearwall 24f1 vv1 Froof j -Percent shearwall wind increase := "no" direct_applied := "yes" 'Percent := 50%1 v = 15.86 plf nail size := 8 Sheathing grade: edge_spacing := 6in Sheathing thickness: HF_reduction := "yes" {18% reduction if hem -fir studs are used} (max_height_opening := Ofij 'perforated_multiplier = 1.00' For 0.469 in. Wood Structural Panel applied directly to framing w/ 8d nails @ 6 in. edge spacing. 'Since v = 16 lb /ft <= N./ = 230 lb /ft OK Mot Froof_I hplate IAt := 5ft + 6irl Mres IFroof I = 761.21 lb Seismic Govems Longitudinal Load. I sheathing := "Wood Structural Panel" 15 thickness := —in in {40% allowable increase permitted per 2306.4.1) M = 3.04kip•ft {Per IBC Table 2305.3.7.2) wallow = 230 p11 2 2 21 2 !wall lwal 31 wall !wall DI-roof 2 + Pwvll. 8 + Pwvlw 8 ) .At + DI-wall 2 •hplate Mres = 17.55 kip•ft Since Mres 17.5 k - ft >= Mot = 3.0 k -ft OK P: \0 PROJECTS116000\16300\16322 TS170 561964 McGINNIS & ASSOCIATES Consulting Engineers, Inc. 1110 Westmark Drive Saint Louis, Missouri 63131 -1735 JOB: TS Accessory Building - PPRS #170 - 561964 NO. 16322 SHEET NO. 13 OF 13 CALC. BY CJD DATE 7/22/2008 Overall Overturning: Driving Forces: Overturning Moments: Uplifting Moment: Combined Driving Moment: Resisting Moment: B B Muplift —Pwvtw•L•3 8 - Pwvtl'L• 8 Mdriving max(Mot1 + Muplift Mot2) B1 Mres Ws_ot• ) .0.6 Tension Required: hpeak Mot1 Pwhtr L 2 Mot2 FEQ•hplate 'Since M res 23.2 < Mdriving 25.8 Uplift. Check tension. I Mdriving — Mres tension :— B (Since Tension 259.3 lb <= 1000.0 lb Sill Plate will Suffice. Foundation Design: Max allowable bearing pressure: Roof Tributary Width: Consider Continuous Wall Footings: IFb := 1500psl Required Frost Depth: B twroof 2 + Boyer Ihplate = 8 ft Wall Height: Max axial load per foot of wall: Pmax TLrooftwroof+ DLwall•hplate Minimum footing width required: Pmax bfooting Fb (bfooting = 2.3 in (footing 12in I Use 8" wide x 12" deep footing minimum. I IP max = 284 plf 'Mot' = 12.71 kip.1 IMot2 = 6.09 kip •fj IM uplift = 13.06 kip•1 (Mdriving = 25.77 kip•fi IMres = 23.18 kip.f 'tension = 259.31 lb P: \0 PROJECTS \16000 \16300 \16322 TS170 561964 03 -02 -2008 TERRY CAMPBELL 17500 WEST VALLEY HY TUKWILA WA 98188 RE: Permit No. D08 -388 16201 WEST VALLEY HY TUKW Dear Permit Holder: city of zu 'la Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/04/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, uv� xc: fer Marshall, t Technician Permit File No. D08 -388 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 July 31, 2008 Terry Campbell 17500 West Valley Hy Tukwila, WA 98188 Dear Mr. Campbell, Brenda Holt Permit Coordinator Enclosures File: D08 -388 • City of Tukwila Department of Community Development RE: Letter of Incomplete Application # 1 Development Permit Application D08 -388 Residence Inn — 16201 West Valley Hy Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, P:U'ermit CenterUncomplete Letters \2008008-388 Incomplete Ltr # I.DOC jem 0 Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you that your permit application received at the City of Tukwila Permit Center on July 30, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Public Works Department: Joanna Spencer at 206 431 -2440 if you have any questions concerning the attached comments. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 DATE: July 30, 2008 • 0 PUBLIC WORKS DEPARTMENT COMMENTS PROJECT: Residence Inn 16201 W Valley Hwy PERMIT NO: D08 - 388 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) On your site plan please mark the location of proposed shed and show dimensions from the property lines or from the existing building. P: joanna/comments 1 D08 -388 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -388 PROJECT NAME: RESIDENCE INN SITE ADDRESS: 16201 WEST VALLEY HY Original Plan Submittal Response to Correction Letter # DATE: 08 -05 -08 X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: �► b uil ing 'vision ubllc_ Works „li Structural Fire Prevention n Pi 6.1 Planning t ivision U Permit Coordinator X G ERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 08 -07 -08 Complete Comments: Documents/routing slip.doc 2 -28 -02 u Incomplete APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: Not Applicable ❑ Permit Center Use .Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 09 -04 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -388 DATE: 07 -30 -08 PROJECT NAME: RESIDENCE INN SITE ADDRESS: 16201 WEST VALLEY HWY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public W rks 1411-'11-06 Structural c� iwi . ¢� DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 1 X 17 LETTER OF COMPLETENES A / ICED: Ping ❑ PW Di Staff Initials: Departments determined incomplete: Bldg ❑ Fire ❑ TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 P ERMIT COORD COPY af° PLAN REVIEW /ROUTING SLIP jl D1DD gi rJ41/V) Fire Prevention ►� ❑ Structural Review Required Planning Division ❑ Permit Coordinator DUE DATE: 07 -31 -08 Not Applicable No further Review Required DATE: DATE: El DUE DATE: 08 -28 -08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: R- _0 Plan Check/Permit Number: D08-388 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: RESIDENCE INN Project Address: 16201 West Valley Hy Contact Person: Terry Campbell Summary of Revision: 0 'lTE P1—W W u C___1__sz 5 - v \ L\ tOCIS S EC IVED AUG 05 2008 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: gr Entered in Permits Plus on 06/(15/4 c \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: h Phone Number: 4 25 1-- g6S3 Name Role Effective Date Expiration Date SAUREY, TOM Cancel Date 01/01/1980 Bond Amount LANGTON, STEVE 3 01/01/1980 019S103129048BCMQ06/26/2002 PROLOW, LEE Until Cancelled 01/01/1980 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CASUALTY Et SUR CO OF 019S103129048BCMQ06/26/2002 Until Cancelled $12,000.00 06/28 /2002 2 TRAVELERS CASUALTY Et SURETY CO 19S103129048BCM 11/30/199806/26 /2002 $6,000.00 UNITED Until Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. TUFF SHED INC Business and Licensing Information Name TUFF SHED INC UBI No. 601645132 Phone 4252518833 Status ACTIVE Address 17500 W VALLEY HWY STE License No. TUFFSI`038RZ 100 Suite /Apt. License Type CONSTRUCTION CONTRACTOR City TUKWILA Effective Date 12/9/1997 State WA Expiration Date 7/2/2009 Zip 981885500 Suspend Date County KING Separation Date Business Type CORPORATION Previous License Parent Company Next License Associated License Specialty 1 GENERAL Specialty 2 UNUSED Business Owner Information • • Bond Information Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License = TUFFSI * 03 8RZ 08/18/2008 • Legal description MEADER HENRY D -C #46 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RI 8501030748 SD SHORT PLAT OAF - POR NW 1/4 OF SEC 25 -23 -04 - BAAP ON WLY R VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HW TH FR SD POB ALG SD WLY R/W LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -C AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON I STRANDER BLVD TH ALG SD NLY RIW LN TANGENT TO PRECEDING CURVE S 81 -C TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TX LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LN S 87 -12 -48 E 194.01 FT Ti OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08 -52 -29 E 165.06 FT TO TPOI 62c. 1 `v i • V�l_t 000 6 0000 Cn Lc. P (Le F` 4• 44- f\cAE5 1JNI S k-k : • • . ".Q . Tt • r. *- „...q..„.., N s•. •••••••••1.,• • � • ,, • "M.•y .••3 • " •, •M '" .• MT 4, NOT tQ • • I, • • . .#1, ..#1, A .//,r,%;,. Y be.0 i • •' •+:r• lir I mo• • 1� • off S • •• A 'I • • ^r , . i �: 4451 /4211%449212; t AT.l , tt t + t A ►," err, . tj* G t(r ItiNt 1 P t •t.hh swum �•��17fi+;i AK* +�rM N,� n� asp � A n1�;�4 ,,�,,, hfi W iiz i�f:'i'+I�I Ktt. •j tall t4? R+C►yti LS Ater ft: i3�i )tllp Y "tot i4i ?64 t�4 31• ,Ar4r.r 1Aiit1�l 5 •• •, M • o •• cvb • .A,.•• IIP4H. l • = • •S'"yir.� tjj ..t ww tM 41.: 41111: / 4 44 11.91: 11 tiM1 ••►.r1 y l 1 •.Ip•• r •MrIMH• .14 • 7 •? � ,, w ma* so tr 1 , 4, , � •PV'u1AM • •• '• •� 1 �.•.r.. •..r w •q , w►•n•N••b1 ..• rI. it . 644 ••• "..114,1 "..114,1 � • .�•• 1p1.4. K..•.• ;• r• • t• 7. ip 11.1 oft ItO•11111 . 1: • : C. i , s'... / 111414A0WW* 0,14$•041 , .t>�� *. , •. I 45, . i / ,4t/,if41e 44 ,,... Y ,� "s meet, K• 1 t s . j/11/ tr y 'v. •. • 1 1j•••d•Ir• • � ! • J . M V• ••'�tiiRt�.`�»N f''}/• A • yy , •... yh i 1: • .IA ,1�•.. • r., s .., ? t t 4 , .. � M • ,� y 1 r I •• ♦•ww•.IH04.4• t.• • ••wp ••M,• „• • tint $ 4 4 t • w • • • •af ••M,••. ; • ��•�• 11 • q1.•�w. 1,w ••y . .••.4•V w1 � ••.. MI1.• f• .••yylY ' ••M•M,1.V' • ?.b .• • IV ,4 j1RKrf 1r o.isn+ye 4; ot• • w. 1•, • Jrfll 0:1101: I R _�- N o changes shall be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions will require a new plan submittal and may.include additional plan review fees. -I ,, ..�..... -J •% • ' I. • •� • � . r r �I '� u � / �1,+V •• i M . •It 1 {I - • •• E '' i.•'• • •.I v (4 411* t i i s.t4` .4* set 0 1•4141 pie �'.. �lktt , ,. �r •p j� '' �, : ott Att.fela .4:44 re 1 It O . .•I.. 3 . '1 ` ... 'G, • t 1 ••i f,y1 f tv r. •1 ; 4 1 1, . ..Y . 1� 44 .• 1 • SEPARATE PERMIT REQUIRED FOR: i iMechanical U Electrical I /Plumbing iJ Gas Piping City of Tukwila BUILDING DIVISION • t I , ., tr•. M. 44 41/,•, J IU.••• kije • I • �• 4 .4 c +5:11441 ' • • J.'� t�� ` ..1... , • 1 I �•..y y.`dli_r.''.r.� 4•••4440;4626;x1‘; '•.• err ± �.� r..r • . • •MI�fI ••. � Ir 1 .4 Lt .:1.. ��. r'; •�If �w, • » •I�•�r�ly i ^ 1,� 1 ' ► MWIN' ~ , R nJ�iN.....•..1vl.i '''. • • L v�.vruu,+.Jr '�rt•�rw�!,1�• �" :wrwM�,5. �� f !1 . 1 • FILE COPY Permit No. 0 94 Plar review approval Is subject to errors and omissions. Approval of construction documents does not authoize• the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledge`'' B Date: City e? Tu Tukwila r 1. ' , 1 , ? LI1vISII 11 f 1 ,14' •; 1 tY, tlglrnv r ryt +, � + '+ rw ;7'9'>r•'. irii/ r'�:•� • . �� •i,•!/�r+�,y f� r.aw � x;•�:�h't• ; , •. e.14 : 7 • 42/r 6 'ij .• iltle41,, Ir i ' t it ,fiii. t:•5 N7 Ve-% � i • . • �t� ,rse.), . • /kite 901 • f� 94 1 t• .'41, : lIfit /«�, . sr��lld /42 0/ j is•f .•vJ• '. !'�'Ik,iiiyi ft;er•� // , '•Rh 7 11 =T .. .. 4. • : .1 • . • • t 4 .f • 1: INCOMPLETE . 1) 0 8 41. 3 8 8 RECEWED AUG 0520 PERMIT CENTER WALL A ELEVATION WALL C ELEVATION FINISHED GRADE FINISHED GRADE ACCESSORY BUILDING -PPRS DRAWING INDEX Al - PROJECT NOTES, ELEVATIONS A2 - PLANS, SHEAR WALL SCHEDULE A3 - SECTIONS, DETAILS 10' X 24' = 240 SQ FT /1 ■ a ■ ■ 2% DOWNSLOPE FOR 5' MINIMUM ON ALL SIDES FINISHED GRADE 2% DOWNSLOPE FOR 5' MINIMUM ON ALL SIDES FINISHED GRADE 6" 6" WALL B ELEVATION WALL D ELEVATION 1270 DOOR 12' -0" 24' -0" 24' -0" 0 6" 6" DESIGN REQUIREMENTS 1. GOVERNING CODES: 2006 IBC OCCUPANCY REQUIREMENTS: GROUP U CONSTRUCTION TYPE: V -B 2. DESIGN SCHEDULE A. BUILDING SIZE WIDTH: 10' -0" LENGTH: 24' -0" SIDE WALL HEIGHT: 8' -0" TOTAL HEIGHT: 10' -3 1/2" B. BUILDING LOADS ROOF LIVE LOAD: 30 PSF ROOF DEAD LOAD: 10 PSF C. DESIGN WIND 3 SECOND GUST, V3 s: 85 MPH WIND EXPOSURE: C D. SEISMIC DESIGN CATEGORY: D2 E. SITE CLASS: D F. ROOF PITCH: 5/12 PROJECT NOTES 3. ROOFING SCHEDULE A. ROOF SHEATHING SHALL BE APA RATED 15/32" THICK 4 -PLY CDX PLYWOOD. STAGGER LAYOUT PER APA CONDITION 1. B. PI #32/16 MIN UNBLOCKED. C. MIN GRADE PLYWOOD AT OVERHANGS TO BE CDX OR 1X T &G SHEATHING. D. SHEATHING NAILING SHALL BE PER NAILING SCHEDULE. E. 20 YEAR FIBERGLASS SHINGLES (CLASS A) (U.N.O.). F. 15 LB. ROOFING FELT. G. TYPE 'D' METAL DRIP EDGE FLASHING REQUIRED ALL SIDES. H. TRUSSES SHALL BE SPACED @ 24" OC. J. SEE SEPARATE TRUSS SHEETS FOR TRUSS FRAMING AND MATERIALS. K. TRUSS CONNECTION PLATES 'EAGLE METAL PLATES' ICC #ESR 1082. L. THE TRUSS PLATE INSTITUTE (TPI) (NER QA 430) IS THE INSPECTION AGENCY RESPONSIBLE FOR IN -PLANT INSPECTIONS. M. TRUSS MANUFACTURER: TUFF SHED, INC. 4. WOOD FRAMING B. ALL WALL FRAMING MEMBERS SHALL BE STUD GRADE OR BETTER WITH TH FOLLOWING DESIGN VALUES: Fb = 675 PSI, Ft = 400 PSI, Fv = 75 PSI Fc = 800 PSI PARALLEL TO GRAIN, E = 1,200,000 PSI. C. STUDS SHALL BE SPACED @ 16" OC. D. FASTEN EXTERIOR WALL SHEATHING TO FRAMING PER NAILING SCHEDULE. E. PROVIDE SOLID BLOCKING AT ALL HORIZONTAL JOINTS OCCURRING IN BRACED WALL PANELS PER 2308.9.3. F. SHEAR WALL MATERIAL SHALL BE AS SPECIFIED IN SHEAR WALL SCHEDULE G. SHEAR WALL NAILING SHALL BE AS SPECIFIED IN SHEAR WALL SCHEDULE. 5. SOIL A. MIN. REQUIRED SOIL TYPE SHALL BE CLAY, SANDY CLAY, SILTY CLAY, OR CLAYEY SILT (CL, ML, MH & CH). PRESCRIPTIVE ALLOWABLE SOIL BEARING PRESSURE USED IN DESIGN IS 1500 PSF AT 12" DEEP. VALUES ARE PER TABLE 1804.2. B. IN THE EVENT OF THE DISCOVERY OF EXPANSIVE SOILS, FOUNDATION WILL EXTEND MIN. 2' -0" BELOW GRADE. C. ALL FOOTINGS SHALL BE FOUNDED ON UNDISTURBED NATURAL SOIL. D. IN THE EVENT EXCAVATIONS REVEAL UNFAVORABLE CONDITIONS, THE SERVICES OF A SOILS ENGINEER MAY BE REQUIRED. 6. PERMIT A. PLRMIT APPLICATIONS, WHERE NO PERMIT IS ISSUED, SHALL EXPIRE PER LIMITVIONS SET BY LOCAL CODES. SECTION 105.5. B. JC3 CARD REQUIRED TO BE AVAILABLE FOR SIGNATURE AT JOB SITE GENERAL NOTES 1. GENERAL: A. ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. BUILDER SHALL PROTECT ALL ADJACENT PROPERTY, STRUCTURES, T'; ZEES, UTILITIES, ETC. B. BUILDER IS RESPONSIBLE FOR SAFETY OF BUILDING DURING CONSTRUCTION. PROVIDE ALL SHORING OR BRACING AS REQUIRED AND PER GOVERNING REGULATIONS. C. ALL WOOD CONSTRUCTION CONNECTORS REFERENCED IN THIS DRAWING SHALL BE SIMPSON 'STRONG -TIE' OR EQUIVALENT. D. GREEN VINYL SINKER NAILS DO NOT MEET THE NAILING REQUIREMENTS OF COMMON NAILS. 2. PLYWOOD DIAPHRAGMS PRODUCT STD PS 1 -95, DOUGLAS FIR - LARCH, STRUCTURAL 1 (OR CDX). 3. MATERIAL EVALUATION REPORT IDENTIFICATIOND A. TRUSS CONNECTION PLATES BY EAGLE METAL PLATES PER ICC ES REPORT #ESR -1082. B. DURATEMP SIDING BY STIMPSON LUMBER COMPANY IS APPROVED FOR USE WITHOUT UNDERLAYMENT PER ICC ES REPORT #ER -4856. C. HARDIPANEL SIDING BY JAMES HARDIE BLDG PRODUCTS PER NES REPORT #NER -405 D. SMARTSIDE SIDING BY LP CORPORATION PER ICC REPRT #ESR -1301. E. LAMINATED VENEER LUMBER (LVL) PER ICC ES REPORT #ESR -1387. F. PHD PRE - DEFLECTED HOLDOWNS BY SIMPSON PER ICC ES REPORT #ER -5328. G. SSTB ANCHOR BOLTS BY SIMPSON PER ICC ES REPORT #ER -4935. D08- 388 RECER/Fr JUL- 3 0 2008 PERMIT CENTEr r ' 6y ca 6„ / r co f \` .1, cr,D, U f - C F \ � . 6 U Pl '0 I I UUNNULLINU LNtiINtt.KJ, INU. 1110 WESTMARK DRIVE SAINT LOUIS, MISSOURI 63131 PHONE: (314) 469 -6460 #16322 IC I III PO No. 561964 Inv No. 383864 Customer: RESIDENCE INN Description: ACCESSORY BUILDING -PPRS 10' X 24' = 240 SQ FT Site Address: 16201 WEST VALLEY HWY TUKWILA, WA 98188 I DRAWINGS ARE FOR A BUILDING TO BE SUPPLIED AND BUILT BY TUFF SHED. ANY OTHER USE IS romow c 1 2 1 \kj .......t .j ■ ■ - - ■ - - Storage Buildings & Garages ( , 1 TUFF SHED, INC. 17500 W. VALLEY HWY TUKWILA, WA 98188 t a. Drawn By: N.B. Date: 07/15/08 Checked By: CJD Date: 07/22/08 Revised: Revised: Title: PROJECT NOTES ELEVATIONS Scale: 1/4" = 1' -0" Sheet: Al Sheet 1 of 3 WALL A ELEVATION WALL C ELEVATION FINISHED GRADE FINISHED GRADE ACCESSORY BUILDING -PPRS DRAWING INDEX Al - PROJECT NOTES, ELEVATIONS A2 - PLANS, SHEAR WALL SCHEDULE A3 - SECTIONS, DETAILS 10' X 24' = 240 SQ FT /1 ■ a ■ ■ 2% DOWNSLOPE FOR 5' MINIMUM ON ALL SIDES FINISHED GRADE 2% DOWNSLOPE FOR 5' MINIMUM ON ALL SIDES FINISHED GRADE 6" 6" WALL B ELEVATION WALL D ELEVATION 1270 DOOR 12' -0" 24' -0" 24' -0" 0 6" 6" DESIGN REQUIREMENTS 1. GOVERNING CODES: 2006 IBC OCCUPANCY REQUIREMENTS: GROUP U CONSTRUCTION TYPE: V -B 2. DESIGN SCHEDULE A. BUILDING SIZE WIDTH: 10' -0" LENGTH: 24' -0" SIDE WALL HEIGHT: 8' -0" TOTAL HEIGHT: 10' -3 1/2" B. BUILDING LOADS ROOF LIVE LOAD: 30 PSF ROOF DEAD LOAD: 10 PSF C. DESIGN WIND 3 SECOND GUST, V3 s: 85 MPH WIND EXPOSURE: C D. SEISMIC DESIGN CATEGORY: D2 E. SITE CLASS: D F. ROOF PITCH: 5/12 PROJECT NOTES 3. ROOFING SCHEDULE A. ROOF SHEATHING SHALL BE APA RATED 15/32" THICK 4 -PLY CDX PLYWOOD. STAGGER LAYOUT PER APA CONDITION 1. B. PI #32/16 MIN UNBLOCKED. C. MIN GRADE PLYWOOD AT OVERHANGS TO BE CDX OR 1X T &G SHEATHING. D. SHEATHING NAILING SHALL BE PER NAILING SCHEDULE. E. 20 YEAR FIBERGLASS SHINGLES (CLASS A) (U.N.O.). F. 15 LB. ROOFING FELT. G. TYPE 'D' METAL DRIP EDGE FLASHING REQUIRED ALL SIDES. H. TRUSSES SHALL BE SPACED @ 24" OC. J. SEE SEPARATE TRUSS SHEETS FOR TRUSS FRAMING AND MATERIALS. K. TRUSS CONNECTION PLATES 'EAGLE METAL PLATES' ICC #ESR 1082. L. THE TRUSS PLATE INSTITUTE (TPI) (NER QA 430) IS THE INSPECTION AGENCY RESPONSIBLE FOR IN -PLANT INSPECTIONS. M. TRUSS MANUFACTURER: TUFF SHED, INC. 4. WOOD FRAMING B. ALL WALL FRAMING MEMBERS SHALL BE STUD GRADE OR BETTER WITH TH FOLLOWING DESIGN VALUES: Fb = 675 PSI, Ft = 400 PSI, Fv = 75 PSI Fc = 800 PSI PARALLEL TO GRAIN, E = 1,200,000 PSI. C. STUDS SHALL BE SPACED @ 16" OC. D. FASTEN EXTERIOR WALL SHEATHING TO FRAMING PER NAILING SCHEDULE. E. PROVIDE SOLID BLOCKING AT ALL HORIZONTAL JOINTS OCCURRING IN BRACED WALL PANELS PER 2308.9.3. F. SHEAR WALL MATERIAL SHALL BE AS SPECIFIED IN SHEAR WALL SCHEDULE G. SHEAR WALL NAILING SHALL BE AS SPECIFIED IN SHEAR WALL SCHEDULE. 5. SOIL A. MIN. REQUIRED SOIL TYPE SHALL BE CLAY, SANDY CLAY, SILTY CLAY, OR CLAYEY SILT (CL, ML, MH & CH). PRESCRIPTIVE ALLOWABLE SOIL BEARING PRESSURE USED IN DESIGN IS 1500 PSF AT 12" DEEP. VALUES ARE PER TABLE 1804.2. B. IN THE EVENT OF THE DISCOVERY OF EXPANSIVE SOILS, FOUNDATION WILL EXTEND MIN. 2' -0" BELOW GRADE. C. ALL FOOTINGS SHALL BE FOUNDED ON UNDISTURBED NATURAL SOIL. D. IN THE EVENT EXCAVATIONS REVEAL UNFAVORABLE CONDITIONS, THE SERVICES OF A SOILS ENGINEER MAY BE REQUIRED. 6. PERMIT A. PLRMIT APPLICATIONS, WHERE NO PERMIT IS ISSUED, SHALL EXPIRE PER LIMITVIONS SET BY LOCAL CODES. SECTION 105.5. B. JC3 CARD REQUIRED TO BE AVAILABLE FOR SIGNATURE AT JOB SITE GENERAL NOTES 1. GENERAL: A. ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. BUILDER SHALL PROTECT ALL ADJACENT PROPERTY, STRUCTURES, T'; ZEES, UTILITIES, ETC. B. BUILDER IS RESPONSIBLE FOR SAFETY OF BUILDING DURING CONSTRUCTION. PROVIDE ALL SHORING OR BRACING AS REQUIRED AND PER GOVERNING REGULATIONS. C. ALL WOOD CONSTRUCTION CONNECTORS REFERENCED IN THIS DRAWING SHALL BE SIMPSON 'STRONG -TIE' OR EQUIVALENT. D. GREEN VINYL SINKER NAILS DO NOT MEET THE NAILING REQUIREMENTS OF COMMON NAILS. 2. PLYWOOD DIAPHRAGMS PRODUCT STD PS 1 -95, DOUGLAS FIR - LARCH, STRUCTURAL 1 (OR CDX). 3. MATERIAL EVALUATION REPORT IDENTIFICATIOND A. TRUSS CONNECTION PLATES BY EAGLE METAL PLATES PER ICC ES REPORT #ESR -1082. B. DURATEMP SIDING BY STIMPSON LUMBER COMPANY IS APPROVED FOR USE WITHOUT UNDERLAYMENT PER ICC ES REPORT #ER -4856. C. HARDIPANEL SIDING BY JAMES HARDIE BLDG PRODUCTS PER NES REPORT #NER -405 D. SMARTSIDE SIDING BY LP CORPORATION PER ICC REPRT #ESR -1301. E. LAMINATED VENEER LUMBER (LVL) PER ICC ES REPORT #ESR -1387. F. PHD PRE - DEFLECTED HOLDOWNS BY SIMPSON PER ICC ES REPORT #ER -5328. G. SSTB ANCHOR BOLTS BY SIMPSON PER ICC ES REPORT #ER -4935. D08- 388 RECER/Fr JUL- 3 0 2008 PERMIT CENTEr { ` i I J 9 ! C r- � O Drawn By: N.B. Date: 07/15/08 Checked By: CJD Date: 07/22/08 Revised: Revised: Title: PLANS SHEAR WALL SCHED NAILING SCHEDULE Scale: 1/4" = 1' -0" Sheet: A2 Sheet 2 of 3 NAILING SCHEDULE CHORD SPLICE NAILING: 8 - 16d NAILS EACH SIDE OF SPLICE. TRUSS BLOCKING: (4) - 16d (TOENAILED) FRAMING NAILING: STUD TO TOP PLATE, 2 -16d END NAIL STUD TO SILL PLATE, 2 -16d END NAIL OR 4 -8d TOENAIL DBL. HEADER 16d @ 16" OC ALONG EACH EDGE HEADER TO KING STUD 4 -8d TOENAIL OR 4 -16d END NAIL UNLESS SPECIFIED HEREIN, ALL NAILING SHALL BE PER 2006 IBC TABLE 2304.9.1. UPLIFT TRANSFER: PROVIDE 3 -16d TOENAILS AT EACH END OF TRUSSES. U JVIDE'2X4 SOLID BLOCKING ON ALL UNSUPPORTED EDGES OF PLYWOOD ON SHEAR WALLS. UNBLOCKED ROOF DIAPHRAGM )OF SHEATHING NAILING: BORDER: 8d COMMON @ 6" OC EDGE: 8d COMMON @ 6" OC FIELD: 8d COMMON @ 12" OC A N B 10' -0" SSTB16 SEE FOOTING DETAIL CF -1 REFERENCE SECTION 3/A3 FOR ANCHOR BOLT SIZE, SPACING, AND ADDITIONAL REQUIREMENTS. 87 197 HOLD -DOWN ANCHORS SHALL BE SET AND POSITIONED IN PLACE FOUNDATION P LAN FOUNDATION INSPECTION. BEFORE CALLING FOR SHEAR WALL SCHEDULE 2X4 FRAMING. SHEATHE EXTERIOR WITH 1/2" DURATEMP. 10' -0" LONG TOTAL. 6' USED FOR SHEAR. NAILING: EDGE: 8d COMMON @ 6" OC FIELD: 8d COMMON @ 12" OC PROVIDE SIMPSON PHD2 HOLDOWNS ATTACHED TO END STUDS AND SSTB16 ANCHOR BOLTS. 2X4 FRAMING. SHEATHE EXTERIOR WITH 1/2" DURATEMP. 10' -0" LONG TOTAL. 10' USED FOR SHEAR. NAILING: EDGE: 8d COMMON @ 6" OC FIELD: 8d COMMON @ 12" OC NO HOLDOWNS REQUIRED. N CALC. SHEAR LOAD (lb/ft) 145 87 2X4 TREATED SOLE PLATE TYPICAL ALL WALLS (U.N.O.) ALLOW. SHEAR LOAD (lb/ft) 230 230 B D FLOOR PLAN SHEAR WALL SCHEDULE 2X4 FRAMING. SHEATHE EXTERIOR WITH 112" DURATEMP. 24' -0" LONG TOTAL. (6' +6') = 12' USED FOR SHEAR. NAILING: EDGE: 8d COMMON @ 6" OC FIELD: 8d COMMON @ 12" OC NO HOLDOWNS REQUIRED. TOENAIL BLOCKING TO TOP PLATE: 3 - 8d/ BLOCK 2X4 FRAMING. SHEATHE EXTERIOR WITH 1/2" DURATEMP. 24' -0" LONG TOTAL. 24' USED FOR SHEAR. NAILING: 2 EDGE: 8d COMMON @ 6" OC FIELD: 8d COMMON @ 12" OC NO HOLDOWNS REQUIRED. TOENAIL BLOCKING TO TOP PLATE: 3 -8d/ BLOCK A B 1-o "I 3' -0" 3' -0" x 6-8" DOOR 6' -0" -PHD2 "HOLDOWNS SHALL BE RE- TIGHTENED JUST PRIOR TO COVERING THE WALL FRAMING." 2315.5.6 WALL FRAMING STUDS @ 16" OC D 10' -0" CALC. SHEAR LOAD (lb/ft) 32 16 ALLOW SHEAR LOAD (Ib /ft) 230 150 230 150 A C TO1 r � r L01 A T01 V L01 w C9 0 TRUSSES @ 24" OC DOUBLE TOP PLATES INTERLOCK AT CORNERS N 3' -0 "HEADER 2- 2X4 HF #2 OR 2 -1 3/4 X 3 1/2" LVL ROOF FRAMING PLAN PROVIDE 2X4 BOTTOM CHORD AT TRUSS WITH 6 -16d NAILS @ EACH END. DOUBLED HEADER NAILING: NAIL W/16d @16 "OC ALONG EACH EDGE spa -388 RECEIVED JUL 30 2006 PERMIT CENTEF TOP PLATES CRIPPLES (AS REQ.) SPACER (IF REQ.) DOUBLED HEADER STUD TRIMMER SOLE PLATE FOR OPENINGS UP TO 5' -11 1/2" UNLESS OTHERWISE NOTED NAILING: HEADER TO STUD - 4 -8d TOENAIL OR 4 -16d END NAIL DOUBLED HEADER - 16d @ 16" STAGGERED FACE NAIL REFERENCE TABLE 2304.9.1 HEADER DETAIL NOT TO SCALE FOR OPENINGS 6' -0" AND WIDER UNLESS OTHERWISE NOTED 2X SOLID BLOCKING BETWEEN TRUSSES NAIL SHEATHING TO WALL STUD PER SHEAR WALL SCHEDULE TOP PLATES CRIPPLES (IF REQ.) SPACER (IF REQ.) DOUBLED HEADER STUD DOUBLE TRIMMERS SOLE PLATE SHEAR TRANSFER NOTES: 1. REFERENCE SHEAR WALL SCHEDULE FOR NAILING AND HOLDOWN REQUIREMENTS. 2. REFERENCE ROOFING SCHEDULE FOR MATERIAL AND NAILING REQUIREMENTS. NAIL SHEATHING TO SOLE PLATE PER SHEAR WALL SCHEDULE EDGE NAILING SHINGLES 3/4" = 1' - 0" SEE PROJECT NOTES FOR MATERIALS NAIL TO INTERMEDIATE FRAMING MEMBERS - REFERENCE NAILING SCHEDULE /A2 4'x8' CDX DRIP EDGE RAFTERS AND OR TRUSSES. REFERENCE NAILING SCHEDULE /A2 DIAPHRAGM BOUNDARY TRIM PANEL EDGE IS NOT SUPPORTED BY BLOCKING - UNLESS NOTED. SIDING ROOFING SHEATHING NAILING DTL SHEAR TRANSFER DETAIL TOP PLATES RAFTER OR TRUSS BLOCKING TOENAIL WITH (3) 16D NAILS (2) ONE SIDE (1) OTHER SIDE SHED RAFTER TOE NAILING DETAIL STUDS AS NOTED IN SHEAR WALL SCHEDULE. USE (2) 2X OR (1) 3X OR GREATER STUD. SDS1 /4X3 SCREWS HEX NUT PHD HOLDOWN TREATED SILL PLATE SSTB ANCHOR FOUNDATION SSTB & PHD INSTALLATION NOT TO SCALE 1/4" = 1' - 0" CEILING AND WALLS SHALL BE LEFT UNFINISHED 10' -0" ROOF RIP MUST BE ATTACHED AFTER SOFFIT BOX IS INSTALLED ROOF SHEATHING 1/2" OSB 2x4 BLOCK FASCIA TRIM UNDEREAVE SIDING SIDE CORNER TRIM ATTACH SOFFIT BOX ASSEMBLY TO SIDE WALL & RAFTERS WITH 3" NAILS av STUD RAFTER GABLE TRIM TOP OF SOFFIT BOX MUST ALIGN WITH TOP OF RAFER END CORNER TRIM BUILDING SECTION ATTACH EACH END OF EACH TRUSS TO TOP PLATES WITH H2.5 OR EQUIV CLIPS. WALL FRAMING TO BE 2X4 HF STUD GRADE @ 16" OC. NOT TO SCALE ATTACH 15/32" CDX PLYWOOD SHEATHING TO TRUSSES PER NAILING SCHEDULE. REFERENCE TABLE 2306.3.1. MIN. 3 NAILS PER RAFTER ROOF RIP MIN. OF 2 NAILS PER BLOCK 34" FORESTRIM FASCIA OVERHANG DETAIL DURATEMP SIDING 2X4 BLOCKS 12" O.C. RAFTER SOFFIT BLOCKING 2x4 BLOCK GABLE TRIM END CORNER TRIM U FINISH •h GRADE 3/ 3 CLR. TYP. 4. 1' -0" MIN. 3/4" = 1' -0" or 1/16 scale IRC a UNHEATED GARAGE SPACE #4 CONTINUOUS TOP & BOTTOM CONCRETE FLOG y 4 /�/\\ </i WWF PER NOTES BELOW MONOLITHIC FOUNDATION CONTINUOUS FOOTING NOTES 1. TOP OF SLAB TO BE 6" MIN. ABOVE GRADE. SLAB REINFORCEMENT SHALL BE WWF 6X6 W10xW10 PER ASTM A185. LOCATE AT MID -DEPTH OF SLAB. 2. ALL FOOTING FORMS SHALL BE INSPECTED FOR SIZE AND REINFORCING BEFORE POURING CONCRETE. 3. FOOTINGS SHALL BEAR ON UNDISTURBED NATURAL, COMPETENT SOIL,OR PROPERLY COMPACTED STRUCTURAL FILL. ALLOWABLE SOIL BEARING PRESSURE IS 1500 PSF AT 12" BELOW GRADE. 4. CONCRETE: MINIMUM 28 DAY COMPRESSIVE STRENGTH, fc = 2500 PSI. 5. REINFORCING STEEL: A615, GRADE 40 OR GRADE 60. ALL REINFORCING STEEL SHOWN TO BE CONTINUOUS MAY BE LAPPED A MINIMUM OF 38 BAR DIAMETERS OR 24" MINIMUM, WHICHEVER IS LARGER. 6. SEISMIC DESIGN CATEGORY: D2 A. ATTACH PRESSURE TREATED SOLE PLATE TO THE FOOTING USING 5/8" DIA X 10" LONG 'L' BOLTS WITH NUTS AND 3 "X3 "X1/4" PLATE WASHERS. B. ANCHOR BOLTS SHALL BE EMBEDDED AT LEAST 7" INTO THE CONCRETE AND SHALL BE SPACED NOT MORE THAN 6' OC. C. THERE SHALL BE A MINIMUM OF 2 BOLTS PER SOLE PLATE PIECE WITH 1 BOLT LOCATED NOT MORE THAN 12" NOR LESS THAN 7 BOLT DIAMETERS FROM EACH END OF EACH PIECE. CF -1 FOUNDATION DETAIL THICKENED SLAB D68 RECEIVED JUL 3 0 2008 PERMIT CENTER a 0 Z �. N = ILI }} m w co c & N Revised: Revised: Title: SECTIONS DETAILS Scale: NONE Sheet: Drawn By: N.B. Date: 07/15/08 Checked By: CJD Date: 07/22/08 N Cr) A3 Sheet 3 of 3