Loading...
HomeMy WebLinkAboutPermit D08-400 - WESTFIELD SOUTHCENTER MALL - APPLE STORAGE - DEMISING WALL, DOOR AND FRAMEAPPLES '. 0 GE 821 SOUTHCENTER MALL Parcel No.: 6364200010 Address: 821 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: APPLE STORAGE Address: 821 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: LISA WINTERHALTER Address: 119 S MAIN ST #410 , SEATTLE WA 98104 Phone: 206 624 -3210 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Phone: 206 718 -0960 Contractor License No: BNBUII *990K3 Cityllf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Permit Number: D08 - 400 Issue Date: 09/04/2008 Permit Expires On: 03/03/2009 Expiration Date: 09/12/2009 DESCRIPTION OF WORK: CONSTRUCTION OF NEW DEMISING WALL. DEMOLITION TO ALLOW FOR NEW WALL. INSTALL NEW DOOR AND FRAME. (THIS STORAGE SPACE IS BEHIND TENANT SPACE FOR TORRID.) Value of Construction: $15,000.00 Fees Collected: $536.63 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: lIB Occupancy per IBC: S doc: IBC -10/06 * *continued on next page ** D08 -400 Printed: 09 -04 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City oil/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: DO8 -400 Issue Date: 09/04/2008 Permit Expires On: 03/03/2009 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: Print Name: doc: IBC-10/06 g t Mme: Date: `` 6 `10C2 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: c t /, `OE. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -400 Printed: 09 -04 -2008 Parcel No.: 6364200010 Address: 821 SOUTHCENTER MALL TUKW Suite No: Tenant: APPLE STORAGE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 400 Status: ISSUED Applied Date: 08/12/2008 Issue Date: 09/04/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: doc: Cond -10/06 D08 -400 Printed: 09 -04 -2008 City of Tukwila 16: Maintain fire extinguisher coverage throughout. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 19: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 20: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 21: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 22: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 23: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D08 -400 Printed: 09 -04 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doc: Cond -10/06 Date: /c' ordinances governing or local laws regulating D08 -400 Printed: 09 -04 -2008 Site Address: Contact Person: Hie _ 12.0 14 VS I� Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Q: lApptication.VFonns- Appuicatione On Line3-2006 - Permit Application.doc Revised: 9 -2006 Building Permit No. Mechanical Perini : No Plwrubin Ga Permit No. Public or Permit No. Protect No. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Tenant Name: AD•P P 1- `.��f - 6 GRA a- Property Owners Name: 4 SISIT Mailing Address: f l CP 01 1/4 Rs buy n Name: LA SA �.1 N'�'t1�.�— tAs✓T-C�2 Mailing Address: 1% a SCE • M q 10 E -Mail Address: \ \Saw Q 1)14:1 C) • r C) w King Co Assessor's Tax No.: CO . 3 Co L i 2=0 O I 0 Suite Number: 5-5 Floor: New Tenant: ❑ Yes ZI .. No t .ngPkt4ACL✓'SS eA ( 3 00 7-S - City Ate Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: 2.0 co ev 2 q 3 2I GEa•,> iiA 9TPIo/ City State ' l Fax Number: 20 Co Co Z `i 3 . 2) 3 GENERAL. CONTRACTOR INFORM = (Contractor Information f or f or (pg 4) for Plumbing and Gas Pipin } ) Company Name: P4.1 I*) 1 L#C) F Z S Mailing Address: Z. CP O 1 if A.•V a # 3 •T O S S":11-LE Q , W A*C -1 t' , 21 State Zip Day Telephone: - 20 CO 3 92. 314 of Ri ARCHITECT OF RECORD -- All j plans trust be wet stamped by Arch City E -Mail Address: IMOI rAi... ro n t' r tt CJ bn by •ACIvt Y"S • CO ry ax Number: Contractor Registration Number: Expiration Date: Company Name: P �� d Mailing Address: \ICI. SO . M1 IV ST. *4%0 Contact Person: USX. W 1( -‘,"• T e12- E -Mail Address: 1 S a w P + r o VV \ s A 92910q City w State Zip Day Telephone: 20 CO cD 2 . ` -/ 3 21 0 Fax Number: 2 2.0 es Co 2 �I 32.143 I ENGINEER OF RECORD - AIt plans must be we stamped bey Engineer of Record City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORMATION -- 206- 431 -3670 Will there be new rack storage? ❑ Yes Valuation of Project (contractor's bid price): $ t5 I (C) U Existing Building Valuation: $ t 10111,4 �'s es- — Scope of Work (please provide detailed information): (CI N e T Y2' el- r1 OP C'A\51 N Q► DP-rn©t.,.111ot.a Au T-O 2- aT-»3 ki) _ N4.21-fp., _v■_.) e, +2. 44 faA`M p4 .. No If yes, a separate pennit and plan submittal will be required. Provide Al{ Building Areas hi Squ re on 1' Floor 2 Floor Fl Floor Acec Attacl Garage Detached 0 tgc,;;' A C. Covered Uncovered' ition to iting Structure Type of Construction per 1 Type of Occupancy per IBC 5 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑....... Yes No If `yes ", explain: SEPTIC SYSTEM Department. FIRE PROTECTION/HAZARDOUS MATERIALS: X Sprinklers ❑ Automatic Fire Alarm ❑ None Will there be storage or use of flammable, combustible or hazardous materials in the building? If ”yes', attach list of materials and storage locations on a separate 8 -112 "x 11 " paper including quantities and Material Saf Q)Appbeationsatme- Applications on Iieet3 -2066 - Permit Appticanon.doe Revised: 9 -2066 bb Handicap: Other (specify) ❑ Yes r tY No to Sheets. ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Page 2 of 6 PERMIT APPLICATION NOTES = Applicable to all permits in, this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BITILDINFOVNIR O AU v ,� Signature: Print Name: LAG 1 - Mailing Address: 11 q SO . Date Application Expires: b21121 Date Application Accepted: AGENT Q:4lppbcalion Womse- Applications On Lm&3 -2006 - Petmit npplicuion.doc Revised: 9 -2006 bb ■24.)K1s t ) ( AC •i' 14% N 1 E-v-f iAt --'T C YZ. Day Telephone: 20 CoZLi 3 Z) O 9'29 4y Cit State Zip Date: e> CCP • te7 Staff Initials: Page 6 of 6 i Payee: B N BUILDERS ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 36185 327.00 000/322.100 000/386.904 RECEIPT Parcel No.: 6364200010 Permit Number: D08 -400 Address: 821 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/12/2008 Applicant: APPLE STORAGE Issue Date: Receipt No.: R08 -03134 Payment Amount: $327.00 Initials: WER Payment Date: 09/04/2008 11:47 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 322.50 4.50 Total: $327.00 .5914 39/04 7- ' Tr1L 327.X doc: Receiot -06 Printed: 09 -04 -2008 Receipt No.: R08 -02903 Payee: MARK RONISH ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payment Check 2032 209.63 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 6364200010 Permit Number: D08 -400 Address: 821 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 08/12/2008 Applicant: APPLE STORAGE Issue Date: Initials: JEM Payment Date: 08/12/2008 09:40 AM User ID: 1165 Balance: $327.00 Account Code Current Pmts 000/345.830 209.63 Total: $209.63 • Payment Amount: $209.63 6004 08/12 0 710 .10 TOTAL 209.63 doc: Receiot -06 Printed: 08-12 -2008 Project / t` v �� Type of Inspe n: Addr f e //F /J pate Called: per / Special nstructions: Date Wanted: . . / a.m. p.m. Requester: Sri Phone NQ1 -7�J/C./ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Y 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: o dozi ,/ $60.dO P E1NSPECTIO ' FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: »3 Project: Type of Inspettio N.. u ( Al:iy Add re Date Called: Special Instructions: _ * 0 pri X 1 v e AA 7 J d1 , j eequester: - "A-Th . i<< c Date Wanted: " c4/ P.M. Ph one No: 7,a‘0 -11 1. r -%9d Jai - - f° ) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Ei Approved per applicable codes. COMMENTS: Mai. «hf /4/ e:4 Re rro -fritv (.4•47 //j A) ,m, A* 0 ,fin igi, Corrections required prior to approval. • Inspector: Date: ,„y c - �j ri $60.00 REINSPECT! f NN FEE RE6UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Proje 49 I� J eR . Type of Inspectio • 4 ice ter Addle l i , // S c d Ci.. / / ' , Date Called: Special Instructions: / Dates Wanted: % 7.- ,�-- (] P.m. Requester: Phone No: 1-06 -- 4 ' 5 /-- cC9 INSPECTION NO. ,CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 222»1/ 2 PERMIT NO. V pproved per applicable codes. Corrections required prior to approval. COMMENTS: zil X; (0 Inspector: Date: 2.i. $58.00 REINSP ON FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: il PA Sprinklers: Type of Inspection: 5e , Address: 13 Z i Suite #: c' . M 4- Contact Person: 7- --- - - - - -- - -- - -- Special Instructions: Occupancy Type: Phone No.: 2'•q1- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: I • INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Approved per applicable codes. COMMENTS: riec 6;41_ I $80.00 REINSPECTIION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc CITY OF TUKWILA DEPARTMENT 1/13/06 '4. i)t - LO PERMIT NUMBERS Corrections required prior to approval. T.F.D. Form F:P. 113 ARCHITECTURAL GROUR1P.S. September 8, 2008 City of Tukwila Department of Community Development 6300 Southcenter Blvd #100 Tukwila, WA 98188 RE: Permit #D08 -400 Apple Storage Southcenter Mall Tukwila, Washington Please note a minor correction to the approved plans for the Apple Storage Room TI at the Southcenter Mall. The walls indicated as being demolished under this permit have been removed from the scope and will be demolished under a separate permit at a later date. We have also clarified the notes regarding the existing corridor walls. All new walls at the existing corridor will match the existing rating levels of the existing walls. Please feel free to contact me if you have any questions or comments regarding these adjustments. Sincerely, `7rc(� �i%G L Lisa M. Winterhalter Project Architect PKJB Architectural Group cc: BN Builders Attachment 119 SOUTH MAIN STREET #410 SEATTLE, WA 98104 206 624 -3210 FAX 624 -3243 112 OLDS STATION ROAD, SUITE B WENATCHEE, WA 98801 509 664 -5181 FAX 665 -8750 RECEIVED SEu, ,i 1 MOO PERMIT CENTER ACTIVITY NUMBER: D08 - 400 PROJECT NAME: APPLE STORAGE SITE ADDRESS: 821 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 08 -12 -08 Response to Incomplete Letter # Revision # after Permit Issued Alr 661 u (ding Division lic Woks s - f Complete I V Comments: Notation: Documents/routing slip.doc 2 -28-02 PLAN REVIEW /ROUTING SLIP I REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: r PERMIT COORD COPY 611 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n -At Planning Division Permit Coordinator Not Applicable DUE DATE: 08-14-08 Permit Center Use Only . • INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Approved I Approved with Conditions IT n No further Review Required DATE: DUE DATE: 09-11-08 Not Approved (attach comments) n DATE: Permit Center. Use Only • ; . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS & SURETY CO 10335590008/30/2001 09/07/200709/07 Until Cancelled $12,000.00 09/06/2001 2 TRAVELERS CAS & SURETY CO 10335590001/01/2001 08/30/2001 $6,000.00 02/05/2001 1 UNITED PACIFIC INS CO 6877797 09/07/2000 Until Cancelled 04/27/2001 $6,000.00 Name Role Effective Date Expiration Date BASTIAN, BRAD PRESIDENT 05/23/2001 Amount NIELSEN, JEFF VICE PRESIDENT 05/23/2001 TBKZ91442966027 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 WAUSAU BUSINESS INS CO TBKZ91442966027 09/07/200709/07 /2008 $1,000,000.00 09/05/2007 WAUSAU Untitled Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company B N BUILDERS INC UBI No. 2067180960 Status 2601 4TH AVE STE 350 SEATTLE WA 98121 KING CORPORATION License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602056687 ACTIVE BNBUII *990K3 CONSTRUCTION CONTRACTOR 5/23/2001 9/12/2009 BASTINB000OJ PURODSI984JN GENERAL UNUSED Business Owner Information Bond Information Insurance Information S I Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= BNBUII* 990K3 09/04/2008 GENERAL NOTES 1. THE APPROVED PLANS SHALL NOT BE CHANGED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OFFICIAL. THE APPROVED PLANS ARE REQUIRED TO BE ON THE JOB SITE 2. CONTRACTOR SHALL VERIFY AND CHECK ALL CONDITIONS AND DIMENSIONS AT THE BUILDING. REPORT ANY INCONSISTENCIES TO NE ARCHITECT 3. ALL WORK SHALL MEET LOCAL CODES AND ORDINANCES. 4. ALL NAILING SHALL COMPLY WITH NAILING SCHEDULE OF IBC 5. COMPLIANCE CARD TO BE POSTED VERIFYING INSULATION INSTALLED IN WALLS, CEILINGS AND FLOORS (IF REQUIRED) 6. PROYIDE METAL NAIL STOPPERS TO COVER HOLES IN STUDS WHERE NAILS COULD PUNCTURE PLUMBING AND WIRING 7. MAINTAIN 3' MIN. CLEARANCE BETWEEN CEILING FIXTURES AND INSULATION a ALL WOOD COMING IN CONTACT W/ CONC. SHALL BE PRESSURE TREATED (DECAY RESISTANT). 9. CONTRACTOR DESIGNED ELECTRICAL. SUBMIT TO BUILDING DEPARTMENT FOR PERMIT. 10. CONTRACTOR DESIGNED MECHANICAL. SUBMIT TO BUILDING DEPARTMENT FOR PERMIT 11. METAL DUCTS TO BE INSULATED AND JOINTS TO BE TAPED. 12. BATT INSULATION SHALL HAVE ALL TEARS AND JOINTS SEALED WITH TAPE 13. WALLS TO BE FIRE STOPPED PER ALL CURRENT CODES 14. ALL INTERIOR WALLS ATTACHED TO EXISTING SUSPENDED CEILING SYSTEM TO MEET THE REQ.'S OF CURRENT BUILDING CODES 15. IF ANY ERRORS, OMISSIONS OR INCONSISTENCIES APPEAR IN NE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY NE OWNER OR ARCHITECT IN WRITING OF SUCH OMI5510N5, ERROR OR INCONSISTENCIES BEFORE PROCEEDING WITH THE WORK, OR ACCEPT FULL RESPONSIBILITY FOR COSTS TO RECTIFY SAME. 16. CONTRACTOR SHALL VERIFY CONDITIONS OF EXISTING SUBSTRATE TO RECEIVE NEW FINISHES AND SHALL BE RESPONSIBLE FOR PREPARING THEM TO RECEIVE NEW FINISHES. It ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN ON PLANS ELEVATIONS, SECTIONS AND DETAILS, lS. ALL EXIT DOORS TO BE OPERABLE FROM INSIDE THE BUILDING WITHOUT KEYS OR SPECIAL KNOWLEDGE. l9. WORK RELATED TO THIS TENANT IMPROVEMENT REQUIRING COORDINATION AND MODIFICATION TO NE EXISTING CONSTRUCTION SHALL BE INCLUDED IN THIS PROJECT BY THE GENERAL CONTRACTOR FOR BIDDING AND CONTRACTUAL AGREEMENT. 20. FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA'10, OR REQUIREMENTS OF LOCAL FIRE OFFICIALS. 21. ALL INTERIOR WALL COVERING MATERIALS SHALL BE FIRE RESISTIVE OR SHALL BE TREATED TO BE FIRE RESISTIVE, 50 AS TO RESULT IN A FLAME SPREAD RATING OF AT LEAST CLASS III FOR GENERAL AREAS AND CLASS II FOR EXIT -WAYS DELIYER CERTIFICATE TO LOCAL FIRE DEPARTMENT AS REQD. 22. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS ARE TO BE FIRE STOPPED 23. REPLACE ALL DAMAGED ACOUSTICAL CEILING TILE A5 REQUIRED IN EXISTING CEILING GRID. 24. COORDINATE WITH TENANT FOR LOCATION OF ELECTRICAL, MECHANICAL, AND PLUMBING. 25. EVERY ROOM I5 TO RECEIVE ITS OWN SWITCH. 26. THE ARCHITECT OF RECORD AND /OR THE ENGINEER OF RECORD ARE THE PERSONS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL SUBMITTALS INCLUDING THOSE PREPARED BY OTHERS 4 SUBMITTING THEM FOR AFTER A PERMIT IS ISSUED. THEY ARE RESPONSIBLE FOR REVIEWING THE SUBMITTALS ITEMS 4 INDICATING THAT REVIEW IN WRITING TO THE BUILDING OFFICIAL STATING THAT THE PLANS COMPLY WI THE DESIGN CONCEPT AND CODE REQUIREMENTS. VICINITY MAP SATE & BLDG. STATS TENANT LANDLORD /OWNER TAX ID PROJECT ADDRESS GOVERNING CODE BUILDING TYPE OCCUPANCY TYPE SITE AREA PA AREA UNDER THIS PERMIT DESCRIPTION OF WORK WALL SCHEDULE I D NSELEIL ARCHITECT CONTRACTOR WESTFIELD 11601 WILSHIRE BLVD 14th FLOOR LOS ANGELES, CA 90025 6364200010 SOUTHCENTER MALL 1068 SOUTHCENTER BLVD. SPACE #5 -40 TUKWILA, WASHINGTON S8 EXISTING WALL OR SCHEDULE MEET ALL BUILDING STANDARDS PROJECT TEAM PKJB ARCHITECTURAL GROUP 603 STEWART STREET *707 SEATTLE, WA 98101 206 - 624 -32I0 BN BUILDERS 2601 4th AVENUE "350 SEATTLE, WA 98121 206- 352 -3443 DRAWING LIST SD.1 COYER AND DATA SHEET ALI FLOOR PLANS, REFL CEILING PLAN, DETAILS II SPRI I ED S -I (ACCESSORY TO M) EXISTING - UNCHANGED EXISTING PARKING TO REMAIN UNCHANGED 611 ± 5F (FOR BUILDING DEPT. USE) 23' - 6't LINEAL FEET OF DEMISING WALL DEMOLISH EXISTING WALLS PER PLANS. CONSTRUCT NEW DEMISING WALL FOR NEW STORAGE ROOM. INSTALL NEW RATED DOORS PER PLAN Q 3'- 0'X7' -0' (PAIR) DOOR PER BUILDING STANDARDS DOOR HARDWARE: 3 PAIR BUTTS LEYER HANDLES WALL STOPS KICK PLATES EACH SIDE CLOSER PEEP HOLE 1 -1/2 HOUR ASSEMBLY MECHANICAL, ELECTRICAL AND FIRE PROTECTION UNDER SEPARATE PERMIT BY OTHERS 6' MTL STUD WALL 16' O .C. WITH 5/6' TYPE 'X' GM EA. SIDE. TAPE AND SAND SMOOTH - SOUND BATCS AS REQD ONE HOUR RATED WALLS PER DETAILS MTL STUD WALL 16' D.C. WITH 2 LAYERS 5 /S' TYPE 'X' GM EA SIDE. TAPE AND SAND SMOOTH - SOUND BATTS AS REQD TWO HOUR RATED WALLS PER DETAILS EXISTING WALLS TO BE REMOVED HARDWARE: DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE WRIST TO OPERATE AND SHALL BE READILY OPENABLE FROM EGRESS SIDE WITHOUT USE OF A KEY OR OTHER SPECIAL KNOWLEDGE OR EFFORT. LOCKS AND LATCHES: SHALL BE PERMITTED TO PREVENT OPERATION OF DOORS WHERE THE LOCKING DEVICE 15 READILY DISTINGUISHED AS LOCKED OiLNER WESTFIELD 11601 WILSHIRE BLVD LOS ANGELES, CA 90025 11556e1 X ST 40. H" 111111111111111111 III APPLE COMPUTER NEW STORAGE ROOM for SCALE: NTS SOUTHCENTER MALL IMP n PP PP N�� C 4/ \ \ \ 4 " (J r nil r EXISTING MALL SITE PLAN ' SEPARATE P R iT REQUIRED Mechanical s lectrical m Laing City of Tukwila las Piping Ga s i ��ILOIR�SC O3Vl�iC''a o JI r 7 J 0Ed r REVIEWED FOR CODE COMPLIANCE APPROVED 2 8 2008 aJr Ci Of Tukwila BUILDING DIVISION REVISIONS No changes shall 6e merle to thr- ccrar r of work withol.Jt prior approval of Tukwila Building Division. NOTE: Revisions will require a new PI?n si.lhrni+ +il - and may include additional plan revirsw fees. 1 FILE COPY r � r Permit No. net atditadZI iar review approval is subject to errors end ��r ,pprovat of construction documents does the violation of any adopted code or r L °1 approved Field Co and iirMiiliilos r B c /01/ y of T BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 12 2008 PERMIT CENTER J 0 a a z z w I- w z 0 Ix 0 U_ 0 w 1- CO D rn SEATTLE OFFICE 119 SOUTH MAIN STREET #410 SEATTLE, WASHINGTON 98104 (206) 624 - 3210 FAX 624 -- 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE 0 WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 4879 DRAWN LMW CHECKED GAP DATE 8/06/2008 SCALE AS NOTED JOB No. 08084 D L() J L1.J z 0 rib- 0 Z J U) (7) Q ❑ W J_ § L1.1 oW U I I— 0 REGISTERED AB6HITECT GR A. PERCICH STA WASHINGTON - pp$-ypp SD.1 FiLIN■im OVERALL MALL KEY PLAN 20 GA CONT. HEAD TRACK ATTACHED TO UNDERSIDE OF EXISTING METAL DECK W/ (3) * S SCREWS 6 24' ci �I��Y ' � mrurrulairu� ±j�u::; .r; 6' 20 GA. MTL. STUDS 6 24' OC W/ ONE (I) LAYER OF 5/8' TYPE 'X' GWB EA SIDE. WALL TO FIT INSIDE TRACK HOLD CLEAR I' - DO NOT ATTACH STUDS OR WALL BOARD TO SLIP TRACK PANT GWB SMOOTH FINISH W/ NSUL. AS REQ. BY OWNER OR TENANT. UL'465 XDNI POWER DRIVEN HILTI FASTENER 6 24' OC EMBED 1 -1/2' EXIST. CONC FLOOR TO REMAIN. I ' =1' - ' 1 EXISTING STEEL JOISTS (AS OCCURS) - CUT awe AROUND JOISTS AND FILL ALL GAPS WITH FIRE SAFNG OR ROCK WOOL DEMISING WALL DETAIL I HOUR 20 GA 3' DEEP CONT. HEAD TRACK ATTACHED W/ (3) * S SCREWS Q 24' OC. HOLD TOP OF STUDS 1' FROM TRACK FOR DEFLECTION. 6' 20 GA. MTL. STUDS e 24' OC W/ TWO LAYERS OF 5/5' TYPE 'X' GWB EA SIDE GA FILE UP-1522 XDNI POWER DRIVEN HILTI FASTENER 6 24' OC EMBED I -1/2' EXIST. CONC FLOOR TO REMAIN. A 1 ' =1' - 3' =1' -0" FILL ALL GAPS WITH FIRE SAFING OR ROCK WOOL z CHANNEL X 20 GAUGE 5CTION 1 /4-2 RATED WALL DETAIL DOORFRAME UNDERSIDE OF STRUCTURE EXISTING TRUGTURE 2 POUR METAL STUDS AND (2) LAYERS TYPE 'X' GM EACH SIDE FOR 2 HOUR WALL PER GA FILE ill/P-1522 11/2 HOUR RATED DOOR, FRAME AND HARDWARE SILICONE RUBBER SEAL TYP AT HEAD AND JAMBS '30 MINUTE RATED DOOR PER MALL STANDARD P PLATE DOOR JAMB SIMILAR 2 POUR SCALE: 1/6'. l' -0' NEW LIGHT NG LAYOUT TO BE CONFIRMED WITH TENANT. ELECTRICAL PERMIT BY OTHERS. LIGHTING TO MEET WA. STATE ENERGY CODE ADJACENT AREAS - NO CHANGE, TYPICAL NEW EXIT LT - PARTIAL RCP T I I I I fi � EXISTING STOREFRONT TO REMAIN - NO CHANGES UNDER THIS PEWIT VACANT TENANT SPACE NO CHANGES UNDER THIS PEWIT FUTURE WORK IN ADJACENT AREA UNDER SEPARATE PERMIT NEW DEMISII` x WALL NEW TENANT SPACE I � PROVIDE 5/8' TYPE 'X' GWB AT NEW i WALL. TAPE AND SAND SMOOTH 'WHITE BOX' LEVEL OF FINISH. J EXISTING 1 ELECT EQUIP. NO WORK OE SCALE: 1/S' -1' -0' 1 EXIST. CORRIDOR T DOS- 'ioo REVIEWED FOR — CODE COMPLIANCE APPROVED AUG 2 8 2103 City Of Tukwila BUILDING DIVISION EXISTING 2 HR CORRIDOR WALLS TO REMAIN DEMO EXISTING WALLS AS REQUIRED FOR INSTALLATION OF NEW DEMISING WALL NEW 2 HOUR INFILL REMODEL FLOOR PLAN r REMOVE PORTION OF WALL AND INSTALL NEW RATED DOUBLE DOORS AND FRAME EXISTING RECEIVED ELECTRICAL CITY OF TUMI LA EQUIPMENT AUG 12 2008 PERMIT CENTER • J Q o'm a ¢ Z cn I- ¢ Z W 0 O CD 0 Z o m j w Et Et 0 0 w A A 4 Z � � n CO CO —' V7 U7 m CO 0 tf) aD CO 0 n m Z Z Z 2 Z 0 ❑ 0 ❑ 0 v7 V)V) V) V) > > > > > W W W W D! D' W x D! P K J B SEATTLE OFFICE 119 SOUTH MAIN STREET #410 SEATTLE, WASHINGTON 98104 (206) 624 - 3210 FAX 624 - 3243 WENATCHEE OFFICE 112 OLDS STATION RD. SUITE B WENATCHEE, WASHINGTON 98801 (509) 664 - 5181 FAX 665 -8750 MIME 4879 REGISTERED A ITECT GR A. STA F WASHINGTON DRAWN LMW CHECKED GAP DATE 8/06/2008 SCALE AS NOTED JOB NO. 08084 Al FILE: