Loading...
HomeMy WebLinkAboutPermit D08-426 - WELLS FARGO - PARTITION WALLS AND DOORWELLS FARGO 6815 S 180 ST D08 -426 Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: Tenant: Name: WELLS FARGO Address: 6815 S 180 ST , TUKWILA WA Contact Person: Name: KATHRYN TAYLOR Address: 1932 1ST AVE #408 , SEATTLE WA 98104 Phone: 206 -720 -7001 Contractor: Name: POE CONSTRUCTION Address: PO BOX 1838 , AUBURN WA 98071 -1838 Phone: 253 833 -2400 Contractor License No: POECOI *247QZ doc: IBC -10/06 Cityllif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: FIRST INTER BNK- KIRKLAND Address: WELLS FARGO BANK - 92685 , PO BOX 63931 94163 Phone: DEVELOPMENT PERMIT Permit Number: D08 - 426 Issue Date: 10/29/2008 Permit Expires On: 04/27/2009 Value of Construction: $5,000.00 Fees Collected: $239.63 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2006 Type of Construction: III-B Occupancy per IBC: 0008 DESCRIPTION OF WORK: NEW PARTITION WALLS, (1) NEW DOOR , 83 SQ FT TO BE CONSTRUCTED IN EXISTING OFFICE SPACE * *continued on next page ** Expiration Date: 05/01/2009 D08 -426 Printed: 10-29 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 4Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Permit Number: D08 - 426 Issue Date: 10/29/2008 Permit Expires On: 04/27/2009 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Private: Public: Profit: N Non - Profit: N Private: Public: Permit Center Authorized Signatu I hereby certify that I have read - d ex- ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be comp d th, whether specified herein or not. The granting of this permit does not • • = ume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • r perf rmance of w • k. I am autl�prized to sign and obtain this development permit. Signature: iL I_ .� Date: / Print Name: A- I'7 C l fct- r\J F 1�--- Date: P v dcb This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC-10/06 D08 -426 Printed: 10 -29 -2008 Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: Tenant: WELLS FARGO 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: D08 - 426 Status: ISSUED Applied Date: 09/05/2008 Issue Date: 10/29/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Cond -10/06 D08 -426 Printed: 10 -29 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us • 14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tulcwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 25: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire d.etectors. 26: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) doc: Cond -10/06 D08 -426 Printed: 10 -29 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 30: When walls and ceilings are required to be of fire resistive or noncombustible construction, interior finish materials shall meet the requirements of International Building Code 803. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D08 -426 Printed: 10 -29 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us J EP Date: doc: Cond -10/06 D08 -426 Printed: 10 -29 -2008 SITE LOCATION S S �Q King Co Assessor's Tax No.: VP 23 019 Y Site Address: I Suite Number: Floor: Tenant Name: \N FT 4 -1 0 New Tenant: ❑ Yes P!. No Property Owners Name: W Fl,(--S y P J-9 (7 ,, - TOM Mailing Address: go( 9 3 I�CVQ. � YGl e (}] ct E 10 f Zip CONTACT PERSON - who d contact hen your permit is ready to be issued K.c0 j y. �sct.0 Y Day Telephoner 20(.0 - 5 2/2 700 Mailing Address: l 32 St' At/e # 4O Q Ge_ t✓ LO Y - - ! S 1 O f `, , /� �y�► �y State Zip K_� ol 1 V � �'r"Q ' L Fax Number Zap- 7LO - 251 Name: E -Mail Address: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.vva.us Bu Perm No. be . ' l Plumbing /Gas Permit No. Public Works Permit No. riVO OV1 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** City State 'Oe GDIOS uC.11013 1 w V'Ule y --0/ S ■c 1e (,) - q8 ID City State Day Telephone: 02 S 3 - 29 0 O k�lea7 potc614, - od io .S-3- Q3 - 1PRO S Zip ale Contact Person: E -Mail Address: Contractor Registration Number: ?OE/10L2-1 2, I ' l al 2009 Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 0 132- 1 S r- 8 $- ectt't e. t�l'VI r 4In T � r City Day Telephone: 0(k-et I ,� I - , LC G(� �/ t 9 r -T avekikL ( 'ax Number: u Dyi. 9 P (0I State Zip Zcl - �Lo -7001 2oCo Z_a4 cj cord ENGINEER OF RECORD - All plan must be wet stamped by Engineer of R V/ Contact Person: E -Mail Address: Q:\Applications \Fortes- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh cit Day Telephone: Fax Number: Page 1 of 6 State Zip BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ ( 000 Existing Building Valuation: $ s i : 5Bk3(CX:20 Scope of Work (please provide detailed information): N FAA) PAIaTIT 0 U\D PcLL5 Cl) VU W Grp 12 — e a - 6 SF - '['p 1;5E- C 3QS o► tN YtSTl N)(3 o rF1( ---= SPA . Will there be new rack storage? ❑ Yes PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes El No If "yes ", explain: FIRE PRO TECTION /HAZARDOUS MATERIALS: Sprinklers X Automatic Fire Alarm ❑ None ❑ Other (specify) Will tl{ere be storage or use of flammable, combustible or hazardous materials in the building? El Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. Provide All Building Areas in Square Footage Below Q:\Applications \Fortes- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh No If yes, a separate permit and plan submittal will be required. 611 SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction, per IBC Type of Occupancy per IBC 1 Floor ( O l 3 0 11B 2 Floor 3r Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ ( 000 Existing Building Valuation: $ s i : 5Bk3(CX:20 Scope of Work (please provide detailed information): N FAA) PAIaTIT 0 U\D PcLL5 Cl) VU W Grp 12 — e a - 6 SF - '['p 1;5E- C 3QS o► tN YtSTl N)(3 o rF1( ---= SPA . Will there be new rack storage? ❑ Yes PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes El No If "yes ", explain: FIRE PRO TECTION /HAZARDOUS MATERIALS: Sprinklers X Automatic Fire Alarm ❑ None ❑ Other (specify) Will tl{ere be storage or use of flammable, combustible or hazardous materials in the building? El Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. Provide All Building Areas in Square Footage Below Q:\Applications \Fortes- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh No If yes, a separate permit and plan submittal will be required. 611 SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicab e to all per its in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER I R • UT; !_ I ENT: � - Signature: � /Aril , i _ we - Date Application Accepted: 491-wi n v► ficu,�(cn- I�32 I 4- Ave_ -* 4 Q:AApplications \Forms - Applications On Line A3 -2006 - Permit Application.doc Revised: 9 -2006 hh Day Telephone: City Date: 0 9/ 4 —Tw — O/ c 4m °(lb 3 State Zip Date Application Expires: Staff Initials: g_ Page 6 of 6 Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: Applicant: WELLS FARGO Receipt No.: R08 -03163 Payee: CRAFT ARCHITECTS ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE ID City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3695 239.63 RECEIPT Initials: WER Payment Date: 09/05/2008 03:41 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000/322.100 000/345.830 000/386.904 142.50 92.63 4.50 Total: $239.63 • Permit Number: D08 -426 Status: PENDING Applied Date: 09/05/2008 Issue Date: Payment Amount: $239.63 7072 N/08 ° <707 TOTAL 239.63 doc: Receiot -06 Printed: 09 -05 -2008 Project: Project: � le Type of Inspection: / 7o a F,,., et ( Address: ill S i4 S/- Date Called: Special Instructions: - . r i „/, ?• 'C> v 4,... 030&70 - 0 J Date Wanted: 42 — 9 m. Requester: Phone No: _ 1 -0‘• ---- 5 s - / — /377 INSPECTION NO. CITY OF TUKYVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved pet applicable codes. Corrections required prior to approval. COMMENTS: INSPECTION RECORD Retain a copy with permit Date: PERMIT NO. (206)431 -3670 El $60.00 REINSPEC:TION FEE REQUIRED. Prior to inspectiorf, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Project:_ e ) Type ofpectiotl: v Address: ' ,. . JOAtl f &a .s'r Date Called: / / Special Instructions: a.3 542 Fr Dr-f e. .e Stite_. Date Wanted: � Z — s a.m. Requester: Phone No: 7.0.5— 5 i t — 397 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- N 0 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect a-' :l Date: /2 - s El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Type of Inspection: Ad ess: 1641 n-� J� Date Called: «f Special Instructions: Date Wanted: J 1--/ 2 - () ` aa. p.m. Requester: Phone No: 7,1)c4 — Sn — X 377 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r 60.0 ' EINSPECTION FE � UIRED. Prior to inspection, fee must be pal . -t 6300 Southcenter Bl , Suite 100. Call to schedule reinspection. Date: 1/ -2—`) , !Date: PER T NO. Complete Comments: ACTIVITY NUMBER: D08 -426 PROJECT NAME: WELLS FARGO SITE ADDRESS: 6815 S 180 ST X Original Plan Submittal Response to Incomplete Letter # Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Response to Correction Letter # DEPARTMENTS: „�p,pg p,,,,� 'ot. rCf V�� R _ Building ivlsion Fire Prevention P Words, glior) Structural n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions I Notation: REVIEWER'S INITIALS: n DATE: 09 -05 -08 Revision # After Permit Issued DUE DATE: 09-09-08 DUE DATE: 10-07-08 Not Approved (attach comments) ❑ DATE: JP- q -q -ob Planning Division Permit Coordinator Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: u Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 SAFECO INS CO OF AMERICA 5698019 05/01/2002 Until Cancelled 03/12/2003 $12,000.00 03/05/2002 3 SAFECO INS CO 5698019 05/01/1998 05/01/2002 01/16/2006 REIFSCHNEIDER, CAROL M $6,000.00 01/01/1980 2 SAFECO INS CO OF AMERICA 5698019 05/01/1992 05/01/1998 POE, FRED W $6,000.00 01/01/1980 1 AMERICAN INS CO SLR6355162 11 /09/1981 05/01/1992 $4,000.00 Name Role Effective Date Expiration Date POE, CHARLES E PRESIDENT 03/01/1996 PETERSON, ALAN D SECRETARY 04 /25/2000 FRY, KYLE R TREASURER 03/12/2003 WILLIAMS, WAYNE W VICE PRESIDENT 03/01/1996 CLARK, DENNIS M CHIEF OPERATING OFFICER 07/09/2003 01/16/2006 REIFSCHNEIDER, CAROL M SECRETARY 01/01/1980 07/09/2003 WELFRINGER, SUZANNEM TREASURER 11/09/1976 07/09/2003 POE, FRED W 01/01/1980 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Bond Information POE CONSTRUCTION INC 2538332400 PO BOX 1838 AUBURN WA 980711838 KING CORPORATION Business Owner Information • UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 171004362 • ACTIVE POECOI *247QZ CONSTRUCTION CONTRACTOR 11/9/1976 5/1/2009 GENERAL UNUSED https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= POECOI *247QZ Page 1 of 3 10/29/2008 FA FBO FCIC V 0 J L rt AB AC A/C ACP ACT ADH ADJ ADJT AF AFF AL ALT AP APPROX ARCH ASPH BD BETW BLDG BLK BLDG BM BRG BOT BSMT BUR CAB CB CBU CEM CER CFM CFT CG CHBD CI CJT CLF C LG CJ CLK CLO CLR CM U CNTR CO COL CONC CONSTR CONT CORR CPT CT CTR CY DBL DEPT D ET DF DIA D TAG DIM DISP DN DR DWR DS DW DWG E EA EB EJ EL ELEC ELEV EM EMER ENCL EP EWC EPX EQ EQPT EST EX EXIST EXT FCTY FD FDN FE FEC FIN ABBREVIATIONS ANGLE CENTER LINE DIAMETER OR ROUND NUMBER OR POUND PENNY PERPENDICULAR PLATE ANCHOR BOLT ACOUSTICAL OR AIR CONDITIONING ACOUSTICAL PANEL ACOUSTICAL TILE ADHESIVE ADJACENT ADJUSTABLE ACCESS FLOOR ABOVE FINISH FLOOR ALUMINUM ALTERNATE ACCESS PANEL APPROXIMATE ARCHITECTURAL ASPHALT BOARD BETWEEN BUILDING BLOCK BUILDING BEAM BEARING BOTTOM BASEMENT BUILT UP ROOF CABINET CATCH BASIN CEMENTITIOUS BACKER UNIT CEMENT CERAMIC CUBIC FEET PER MINUTE CONDUCTIVE FLOOR TILE CORNER GUARD CHALK BOARD CAST IRON CONTROL JOINT CHAIN LINK FENCE CEILING CONSTRUCTION JOINT CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT COUNTER CLEANOUT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CORRIDOR CARPET CERAMIC TILE CENTER CUBIC YARD DOUBLE DEPARTMENT DETAIL DRINKING FOUNTAIN(W /0 COOLER) DIAMETER DIAGONAL DIMENSION DISPENSER DOWN DOOR OR DRAIN DRAWER DOWNSPOUT DISHWASHER DRAWING EAST EACH EXPANSION BOLT EXPANSION JOINT ELEVATION ELECTRIC ELEVATOR ENTRY MAT EMERGENCY ENCLOSURE OR ENCLOSED ELECTRICAL PANEL ELECTRIC WATER COOLER EPDXY EQUAL EQUIPMENT ESTIMATE EXPANSION EXISTING EXTERIOR FIRE ALARM FURNISHED BY OTHERS FURNISHED BY CONTRACTOR INSTALLED BY CONTRACTOR FACTORY FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FL FLG FLUOR FM FOC FOF FOI C F010 FOS FS FT FTG FTC FTIO FURR FUT FUTURE - RIO FX FIXED GA GALV GB GL GLBM GEN CONTR GND GR GWB HB HC HDR HDWD HDWE HM HORIZ HR HT HTG HVAC HWH ID IG IHM IN INCL INSUL INT JAN JT KIT KO KS LAM LAV LB LF LG LH LKR LT MACH MAIL MAX MECH MET OR MEZZ MFR MH MIN MIR MISC MLD MRGWB MTD MULL NIC NOM NTS OA OC OD OFF OH OPH OPNG OPP PERP PFN PL P LAM PLYWD PNL PNT PR FLOOR FLASHING FLUORESCENT FACTORY MUTUAL FACE OF CONCRETE FACE OF FINISH FURNISH BY OWNER INSTALL BY CONTRACTOR FURNISH BY OWNER INSTALL BY OWNER FACE OF STUD FULL SIZE FEET FOOTING FURNISHED BY TENANT INSTALLED BY CONTRACTOR FURNISHED BY TENANT INSTALLED BY OWNER FURRING FUTURE FUTURE ROUGH IN ONLY GAGE GALVANIZED GRAB BAR GLASS OR GLAZING GLU -LAM BEAN GENERAL CONTRACTOR GROUND GRADE GYPSUM WALL BOARD HOSE BIB HOLLOW CORE OR HANDICAP HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING H EATING /VENTI LIATIO N/ AIR CONDITIONING HOT WATER HEATER INSIDE DIAMETER/ DIMENSION INSULATED GLAZING INSULATED HOLLOW METAL INCH INCLUDE INSULATION INTERIOR JANITOR JOINT KITCHEN KNOCK OUT KNEE SPACE LAMINATE LAVATORY LAG BOLT LINEAL FOOT LENGTH LEFT HAND LOCKER LIGHT MACHINE MATERIAL MAXIMUM MECHANICAL MTL METAL MEZZANINE MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS MOLDING MOISTURE RESISTANT GYP BD MOUNTED MULLION NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER/ DIMENSION OFFICE OVERHEAD OPPOSITE HAND OPENING OPPOSITE PERPENDICULAR PREFINISHED PLATE OR PROPERTY LINE PLASTIC LAMINATE PLYWOOD PANEL PAINT PAIR PS PSF PSI PT PTD PTD /R PTN PTR PVMT R RA RAD RB R &S RD RD /0 REBAR REF REFR REINF REQ'D REV RH RESIL RM RO RT RUB RVS RW RWL PAINT SYSTEM POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH PRESSURE TREATED PAPER TOWEL DISPENSER PAPER TOWEL DISPENSER AND RECEPTABLE PARTITION PAPER TOWEL RECEPTABLE PAVEMENT QT QUARRY TILE RISER RETURN AIR RADIUS RESILIENT BASE ROD & SHELF ROOF DRAIN ROOF DRAIN OVERFLOW REINFORCING BAR REFERENCE REFRIGERATOR REINFORCED REQUIRED REVISION RIGHT HAND OR ROBE HOOK RESILIENT ROOM ROUGH OPENING RESILIENT TILE RUBBER REVERSE RAIN WATER RAIN WATER LEADER S SOUTH SC SOLID CORE SCD SEAT COVER DISPENSER SCHD SCHEDULE SD SOAP DISPENSER OR SECT SECTION SF SQUARE FEET SHTG SHEATHING SIM SIMILIAR SK SINK SLR SEALER SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SNT SEALANT SPEC SPECIFICATION SQ SQUARE SST STAINLESS STEEL SSK SERVICE SINK ST STONE /STONE TILE STA STATION STC SOUND TRANSMISSION CLASS STD STANDARD STL STEEL STOR STORAGE STRL STRUCTURAL SUSP SUSPENDED SV SHEET VINYL SYM SYMMETRICAL T TREAD TB TOWEL BAR T &B TOP & BOTTOM TG TEMPERED GLASS THK THICK THR THRESHOLD TIG TEMPERED INSULATED GLAZING TO TOP OF TOC TOP OF CONCRETE TOP TOP OF PAVEMENT TOS TOP OF STEEL TOSL TOP OF SLAB TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPH TOILET PAPER HOLDER TPTN TOILET PARTITION TS TUBULAR STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITERS LABORATORY UNF UNFINISHED UON UNLESS OTHERWISE NOTED UR URINAL VAR VARIES VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VIN VINYL VWC VINYL WALL COVERING W WEST W/ WITH W/O WITHOUT WC WATER CLOSET WD WOOD WF WIDE FLANGE WG WIRE GLASS WP WATER PROOF WR WATER RESISTANT WSCT WAINSCOT WT WEIGHT XFMR TRANSFORMER YD YARD 11 REVISION CLOUD AROUND REVISION SYMBOLS COLUMN LINE /GRID LINE DOOR NUMBER TO COORESPOND TO ROOM ENTERING KEY NOTE PARTITION TYPE MATCH LINE SHADED PORTION IS THE SIDE CONSIDERED WORK POINT, CONTROL POINT OR DATUM POINT EQUIPMENT NUMBER GENERAL NOTES BUILDING SECTION (IDENTIFY ON PLAN) SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN SECTION IDENTIFICATION SHEET WHERE SECTION IS DRAWN WALL SECTION (IDENTIFY ON ELEVATIONS) DETAIL DETAIL IDENTIFICATION SHEET WIIERE DETAIL IS DRAWN 9 , -0 " OFFICE 102 68.5 „ INTERIOR ELEVATION(S) ELEVATION IDENTIFICATION SHEET WHERE ELEVATION IS DRAWN ROOM IDENTIFICATION ROOM NAME ROOM NO. ROOM FINISH GRADE EXISTING GRADE PROPERTY LINE NEW OR FINISHED CONTOURS EXISTING CONTOURS TOP OF WALL TOP OF CURB TOP OF PAVEMENT ACTUAL NORTH DENOTES CHANGE IN E LEVATION 1. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS ON THE JOB SITE, INCLUDING THE SAFETY OF ALL PERSONS, PROPERTY, AND FOR ALL NECESSARY INDEPENDENT ENGINEERING REVIEWS OF THESE CONDITIONS, AND FOR COMPLIANCE WITH O.S.H.A. SAFETY STANDARDS. ARCHITECTS AND THEIR CONSULTANTS' JOB SITE OBSERVATIONS ARE NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES. 2. EACH CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH ALL SPECIFIED PRODUCTS RELATING TO THEIR WORK. THEY ARE TO SUBMIT WRITTEN OBJECTIONS PRIOR TO BIDDING, IF THE CONTRACTOR HAS AN OBJECTION TO ANY PRODUCT AND /OR DISCREPANCIES BETWEEN DRAWINGS AND SPECIFICATIONS. 3. THE GENERAL CONTRACTOR SHALL COORDINATE THEIR WORK WITH THAT OF OTHER SEPARATE CONTRACTS SUCH AS SIGNS, & OWNER FURNISHED ITEMS, WHICH ARE BEING DONE BY OTHERS. 4. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE FIELD. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS. ALL WORK IN THAT AREA SHALL BE HELD UNTIL SUCH DISCREPANCIES ARE RESOLVED. 5. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, A.I.A. DOCUMENT A201, THE LATEST EDITION, SHALL BE INSPECTED AT THE ARCHITECTS OFFICE. 6. SEPARATE PERMITS, WHEN REQUIRED AND /OR WHEN WORK ITEMS ARE DESIGN /BUILD IN NATURE, SHALL BE OBTAINED BY THE CONTRACTOR FOR MECHANICAL, PLUMBING, FIRE SPRINKLERS,ELECTRICAL AND FIRE ALARM. DESCRIPTIVE, DETAILED DESIGN AND REQUIRED SUBMITTAL DOCUMENTS INFORMATION SHALL BE PROVIDED FOR REVIEW BY THE REGULATING AUTHORITIES AND BY THE OWNER /TENANT /ARCHITECT FOR APPROVAL PRIOR TO ANY WORK BEING PERFORMED. SEE SPECIFICATIONS FOR REQUIREMENT FOR DESIGN /BUILD FRE SPRINKLER SYSTEM. SUBMIT PLAN TO AND OBTAIN PERMIT FROM THE FIRE PREVENTION BUREAU FOR FIRE SPRINKLER SYSTEM INSTALLATION OR MODIFICATION. 7. COMPLETE FIRE SPRINKLER DRAWINGS WILL BE SUBMITTED BY THE FIRE PROTECTION CONTRACTOR. 8. THE INSTALLATION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE 9. SPECIAL INSPECTIONS WHERE REQUIRED BY THE BUILDING OFFICIAL SHALL BE PERFORMED BY INSPECTORS APPROVED BY THE BUILDING OFFICIAL. 10. ALL WORK DONE SHALL BE IN CONFORMANCE WITH THE APPROVED PLANS AND PROJECT SPECIFICATIONS. THE APPROVED, PERMITTED, STAMPED PLANS ARE TO REMAIN ON SITE AT ALL TIMES. 11. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS OTHERWISE NOTED. 12. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. 13. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF QUESTIONS CAN NOT BE RESOLVED IN THIS MANNER, CONTACT THE ARCHITECT PRIOR TO PROCEEDING. 14. GENERAL CONTRACTOR SHALL PROVIDE OWNER WITH DETAILED CRITICAL PATH SCHEDULE FOR REVIEW AND APPROVAL PRIOR TO START OF CONSTRUCTION. UPDATES OF SCHEDULE SHALL BE MADE AS NECESSARY WITH COPIES PROVIDED TO OWNER. 15. ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE LATEST RULES AND REGULATIONS OF THE INTERNATIONAL BUILDING CODE, NATIONAL ELECTRICAL CODE AND ALL OTHER APPLICABLE STATE OR LOCAL LAWS AND REGULATIONS. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED AS TO PERMIT WORK WHICH IS NOT CONFORMING TO THE PREVIOUS LISTED CODES. 16. PROTECTIVE MEASURES SHALL BE TAKEN BY THE CONSTRACTOR TO PROTECT ADJACENT PROPERTY AT ALL TIMES DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL COMPLY WITH ALL CURRENT APPLICABLE LOCAL ORDINANCES FOR UTILITY SERVICES. 18. LIGHT AND VENTILATION SHALL COMPLY WITH I.B.C., SECTION 1203, 1204 & 1205. 19. FIRE BLOCKING SHALL BE PROVIDED AT ALL FRAMED WALLS AT 10' -0" 0.c. AND ALSO AT ANY LOCATION WHERE WALL FRAMING PENETRATES CEILINGS. REFER TO IBC SEC. 708 FIRE BLOCKING AND DRAFT STOPS FOR CONSTRUCTION. 20. ALL WATER FIXTURES MUST COMPLY WITH WAC 51 -26 -180 WATER CONSERVATION AND /OR ANY JURISDICTION'S PERFORMANCE STANDARDS. 21. WHEN CHANGES TO THE MECHANICAL SYSTEM REQUIRE A MECHANICAL PERMIT THEY SHALL COMPLY WITH THE MOST CURRENT UNIFORM MECHANICAL CODE AND WITH ANY LOCAL JURISDICTION REQUIREMENTS. 22. PROVIDE ILLUMINATED EXIT SIGNAGE AT ALL REQUIRED EXITS. 23. PATCH AND REPAIR ALL EXISTING WALLS FLOORS AND CEILINGS THAT ARE ADJACENT TO AND AFFECTED BY NEW CONSTRUCTION. 24. CONTRACTOR IS TO COMPLY WITH CHAPTER 33 OF THE INTERNATIONAL BUILDING CODE CONCERNING PROTECTION OF PEDESTRIANS DURING CONSTRUCTION. 25. PRIOR TO FINAL INSPECTION, A CERTIFICATE OF CONSTRUCTION COMPLIANCE SHALL BE READY FOR THE INSPECTOR. THE CERTIFICATE SHALL STATE "BASED UPON PERSONAL KNOWLEDGE, THAT THE WORK APPEARS TO HAVE BEEN PERFORMED, AND THE MATERIALS USED AND INSTALLED APPEAR IN EVERY MATERIAL RESPECT IN COMPLIANCE WITH THE PLANS ". THE CERTIFICATE MUST BE SIGNED BY ONE OR MORE OF THE FOLLOWING: (A) OWNER, (B) GENERAL CONTRACTOR, (C) AN APPROVED INDEPENDENT INSPECTOR OR INSPECTION AGENCY. 26. ASBESTOS AND HAZARDOUS WASTE EXCLUSION: THE ARCHITECT HEREBY STATES, AND THE OWNER ACKNOWLEDGES, THAT THE ARCHITECT HAS NO PROFESSIONAL LIABILITY OR OTHER INSURANCE, (AND IS UNABLE TO REASONABLY OBTAIN SUCH INSURANCE FOR CLAIMS ARISING OUT OF THE PERFORMANCE OF OR THE FAILURE TO PERFORM PR OAFE S SIONAL S I NC L D ING BUT NOT BUT TO, HE PREPARATION OF REPORTS, DESIGNS, DRAWINGS, AND SPECIFICATIONS, AND PROJECT DIRECTORY ARCHITECT /CONTACT: CRAFT ARCHITECTS, PLLC. 1932 FIRST AVENUE, STE. 408 SEATTLE, WASHINGTON 98101 ARCHITECT OF RECORD: TENANT /OWNER: GENERAL CONTRACTOR: TAX PARCEL # 3623049095 ZONING DISTRICT: CODE EDITION: CONSTRUCTION EXISTING OCCUPANCY CLASSIFICATION: TYPE OF CONSTRUCTION: SPRINKLER SYSTEM: ACTUAL FLOOR AREAS: 1ST FLOOR: OFFICE (B - EXISTING) NEW SERVER ROOM (WITHIN EXISTING OFFICE) TOTAL ACTUAL FLOOR AREA: OCCUPANT LOAD: (SEC. 1004.1 TABLE 10 A) 1ST FLOOR: OFFICE TOTAL OCCUPANCY LOAD ELECTRICAL, MECHANICAL KATHRYN M. CRAFT WELLS FARGO BANK 999 THIRD AVENUE SEATTLE, WA 98104 LEGAL DESCRIPTION POE CONSTRUCTION 1519 W VALLEY HW. STE 103 KENT, WA PROJECT DESCRIPTION EXISTING PARKING LOT PORS OF GL 4 & OF GL 1 IN SEC 35 LY S OF 1s LN EXTND DAF BEG AT NW COR OF SEC 36 TH S ALG W LN THOF 1355.89 FT TO TPOB & S MGN OF S 180TH ST TH ELY ON CRV LFT CTR BRG N 02 -45 -45 E RAD 336 FT C/A 01 -32 -04 A DIST OF 9 FT TO S LN OF N 36 FT OF SD GL 4 TH S 88 -46 -19 E ALG SD S LN 274.81 FT TH ON CRV RGT RAD 50 FT C/A 90 -00 -00 A DIST OF 78.54 FT TH S 01 -13 -41 W 58 FT TH N 88 -46 -19 W TO SWLY LN OF GL 1 IN SEC 35 TH NWLY ALG SD SWLY LN TO WLY EXT OF N LN OF SD GL 4 TH S 88 -46 -19 E ALG SD WLY EXT TAP 142.38 FT W OFNW COR SD GL 4 TH ON CRV LFT CTR BRG N 27 -59 -36 E RAD 336 FT 147.96 FT TO TPOB TUKWILA URBAN CENTER (TUC) 2006 IBC TENANT IMPROVEMENT OFFICE - (B STORAGE - S -2) IIIB YES SPRINKLERS, YES FIRE ALARM 20,197 SQ FT 83 SQ FT 20,197 SQ FT 20,197 SQ FT / 100 = 202 20,197 SQ FT = 202 EXIT REQUIREMENTS: (SEC. 1019 TABLE 1019.1) NUMBER REQ'D NUMBER PROVIDED ACCESSIBLE PROVIDED 1ST FLOOR: OFFICE 2 2 1 SEPARATE PERMIT SUBMITTALS NEW PARTITION WALLS AND NEW DOOR TO BE CONSTRUCTED IN EXISTING OFFICE BUILDING. Contact: KATHRYN TAYLOR Phone: (206) 720 -7001 Fax: (206) 720 -2949 Contact: TOM DAWES Phone: (206) 292 -3181 Fax: (206) 292 -3475 Contact: KYLE FRY Phone: (253) 833 -2400 Fax: (253) 939 -4805 SITE PLAN NTS EXISTING OFFICE BUILDING AREA OF WORK PROJECT INFO WELLS FARGO OFFICE BUILDING 18035 SPERRY DRIVE TUKWILA, WA 98188 INDEX OF DRAWINGS T1.1 GENERAL INFORMATION A2.1 FLOOR PLAN, REFLECTED CEILING PLAN WALL TYPES,D ETAI LS PARKING REQUIRMENTS SCOPE OF WORK WILL NOT AFFECT PLUMBING FIXTURE REQUIREMENTS By. Date:.,../ v F, tai i n�IS . No changes shall be made to the hal core of work without prior approval Building Division. i NO`T`E: Revisions will require a new plan subm "1 +al and may include additional plan rev fees. DosLIz b E PER, iI I REQUIRED FOR: L iVIF)chanical LLElectrical Plumbin Gas Piping RMATION City of Tukwila DIVISION SCOPE OF WORK WILL NOT AFFECT PARKING REQUIREMENTS PLUMBING FIXTURE REQ'S City of Tul calla BUILDING MOON CO E VI C E 0 v COMPLIANCE E CONSULTANT APPROVED SEP 16 . 2008 City Of Tukwila BUILDING DIVISION Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinanco. Receipt of approved Feld opy conditions is acknowledged; RECEIVED SEP 0520 PERMIT CENTER Terminal Sales Building. 1932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206,720.2949 Fax www, c ra fta rch itects, co m REGISTERED ARCHITECT KATH CRAFT STATE OF WA ISSUE 7052 09 -05 -08 FOR PERMIT Revisions: Sheet Title: Date: Design: Drawn: Project No: Approved: Sheet No: Architect of Record z Q W M II co (3O> a: Q W� _J co W r GENERAL INFORMATION 09/03/08 KMC KLT 08- 161.06 KMR Original drawing is 24" x 36 ". Scale entities accordingly if reduced COPYRIGHT CRAFTARCHITECTS 2008 T1.1 DOOR /RECITE TYPE c, LOCK -BOX SPACE (SHADED AREA) 3' -0" F (FLUSH) DOOR TO MATCH EXISTING OFFICE SINGLE DOORSCOPE, ASB PLASTIC, CHARCOAL, BY G.C. y CENTER IN DOOR FRAME TYPE 1 FRAME TO MATCH EXISTING 3/4" , STUDS, OR WIRE @ 6' -0" O.C. MAX. SECURE TO STRUCTURE ABOVE & FLATTEN TO ATTACH TO STUDS PER MFR'S RECOMMENDATIONS & TO MEET UBC SEISMIC REQUIREMENTS ItmnunMUIREunmf mllfnnnnlll1nmtiDMmm111n1mff1nf EXISTING ACP CEILING 5/8" GWB, - OVER 3 -5/8 "X20 GA. MTL. STUDS @ 16" O.C. W/ SOUND BATTS. SERVER ROOM INTERIOR PARTITION MTL STUD RUNNER ATTACHED TO EXST. CONC. SLAB W/ 5/32" DIA. LOW - VELOCITY POWER- DRIVEN FASTENER W/ 1 1/4" PENETRATION MIN. PER STUD MANUFACTURER'S RECOMMENDATIONS WALL TYPES NTS F1 1/4" = 1' -0" 1 1/2" = 9 EXISTING STORAGE ROOM 108 NEW SERVER ROOM 109 BUILDING FLOOR PLAN REFLECTED CEILING PLAN 1/4" = 1' -0" EXISTING OFFICE 101 1/4" = 1' -0" EXISTING OPEN OFFICE 100 // OFFICE FLOOR PLAN EXISTING STORAGE ROOM 102 NEW SERVER ROOM 103 GENERAL NOTES: 1. ALL EXISTING BUILDING COLUMNS, EXTERIOR WALLS, EXTERIOR WINDOWS, AND STRUCTURAL MEMBERS TO REMAIN, U.O.N. 2. ALL NEW PARTITION WALLS TO BE WALL TYPE 3. EACH ROOM SHALL HAVE SEPARATE SWITCHING BY ELECTRICAL DESIGN /BUILD TO MEET WSEC 1513. 4. ALL FLOORS AND FINISHES EXISTING TO REMAIN. 5. ALL 2X4 LAY -IN FLUORESCENT LIGHTS ARE EXISTING TO REMAIN U.O.N. 6. ALL DOORS SHOWN ARE EXISTING TO REMAIN U.O.N. LEGEND: KEY NOTES: • 0 0 EXISTING EXIT 2X4 LAY -IN FLUORESCENT LIGHT EXISTING PARTITION WALL NEW PARTITION WALL, FINISHED TO MATCH EXISTING ADJACENT EXISTING EXTERIOR WALL, TYP. NEW DOOR WITH LEVER STYLE HARDWARE, CLOSER, ELECTRIC STRIKE, AND CONTROLLED CARD ACCESS. DOOR AND FRAME FINISH AND STYLE TO MATCH EXISTING. EXISTING LIGHT FIXTURE TO BE RELOCATED RELOCATED LIGHT FIXTURE, IN EXISTING CEILING GRID ALIGN EXISTING DOOR TO BE REMOVED ROOM FINISH NOTES: 1. ALL NEW GWB WALLS SHALL RECEIVE A SMOOTH WALL FINISH. 2. PAINT TO MATCH EXISTING bO892 R V1I VVED FOR CODE COMPLIANCE APPROVED SEP 1 6 2008 City Of Tukwila BUILDING DIVISION_ , U.O.N. C a r c h i t e c t s Terminal Sales (Building 1932 First Avenue Suite 408 S e a t t l e , WA 9.8 1 0 1 206.720,7001 phone 206.720.2949 fax www. craftarchitects,crarn CONSULTANT RECEWED SEP 052000 PERMIT CENTEh Sheet No: Architect of Record ISSUE 09 - 05 - 08 FOR PERMIT Revisions: Sheet Title: Date: Design: Drawn: Project No: Approved: FLOOR PLANS 09/03/08 KMC KLT 08- 161.06 KMR Original drawing is 24" x 36 ". Scale entities accordingly if reduced COPYRIGHT CRAFTARCHITECTS 2008 A2.1