Loading...
HomeMy WebLinkAboutPermit D08-427 - HILLCREST APARTMENTS - DECKSHILLCREST APARTMENTS BLDG A 14901 INTERURBAN AV S D08 -427 Parcel No.: 3597000422 Address: 14901 INTERURBAN AV S TUKW Suite No: Tenant: Name: HILLCREST APTS BLDG A Address: 14901 INTERURBAN AV S , TUKWILA WA Owner: Name: HILLCREST ASSOCIATES Address: C/O GRAN INC , 1021 1ST AVE W 98119 Phone: Contact Person: Name: ALICE HART @ GRAN INC Address: 10211 1ST AVE WEST , SEATTLE WA 98119 Phone: 206 - 283 -4720 Contractor: Name: GRAN INC Address: 1021 1ST AV N , SEATTLE WA 98119 Phone: 206 - 283 -4720 Contractor License No: GRANT * *997NF Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 Cit34f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us $69,000.00 DEVELOPMENT PERMIT Permit Number: D08 -427 Issue Date: 09/11/2008 Permit Expires On: 03/10/2009 Fees Collected: $1,651.20 International Building Code Edition: 2006 Occupancy per IBC: DESCRIPTION OF WORK: SHORE UP EXISTING DECKS WITH PIN PILES TO SPEC, FOOTINGS ANSD HEADERS. PLEASE SEE CONSTRUCTION NOTES ON ENGINEERED PLANS * *continued on next page ** Expiration Date: D08 -427 Printed: 09 -11 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City c*7Cukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D08 -427 Issue Date: 09/11/2008 Permit Expires On: 03/10/2009 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signatur Print Name: doc: IBC - 10/06 I hereby certify that I have read an examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli vJith, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction the performance of work. I am authorized to sign and obtain this development permit. Signature: VN-9- nn Date: �'l ( k l ( N. \4', 1■3.ss� Date: 0 ILL IVD This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -427 Printed: 09 -11 -2008 Parcel No.: 3597000422 Address: Suite No: Tenant: 14901 INTERURBAN AV S TUKW HILLCREST APTS BLDG A 1: ** *BUILDING DEPARTMENT CONDITIONS * ** City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -427 ISSUED 09/08/2008 09/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 5: Special Inspection of pipe piling installation is required. 6: Special inspection shall be performed by W.A.B.O. certified special inspector. 7: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 8: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: Cond -10/06 * *continued on next page ** D08 -427 Printed: 09-11 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Print Name: Signature: QP- c Date: l I t (.12 M , VA \o doc: Cond -10/06 D08 -427 ordinances governing or local laws regulating Printed: 09 -11 -2008 SITE LOCATION King Co Assessor's Tax No.: 3 2:2- Site Address: 1 Taterur•oti kve S Suite Number&LJA Floor: Tenant Name: )--1-iiicre.st- Apar-Frverth-s New Tenant: D Yes 0 „No Property Owners Name: i-teler) I- rig irwes7'rriertis.5 , c.c..c.. Mailing Address: IL/693 Triferdrhar) &Le S. #(.0 72,/ bo# 98/( e City State Zip CONTACT PERSON - who'do:ve ntact when your pnit is ready to be issued Airez In L. Day Telephone: 101 ( St- 4 e54-- 5-6-H4e . wig- 9 8// allee9raoiric_.eOm Cit Number: 2e) 123. 5:4 E-Mail Address: z Name: Mailing Address: GENERAL CONTRACTOR,1NFOR.MATION.+:- • • (Contractor Information forAtechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Gtiou 102/ / /1 uks 3 ea IAJ4 93//9' Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hnp: //www.ci. tubs ila. Iva. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** City State Zip Ae W42a.&.17 Day Telephone: 2/Z0 , 2P-,3. 592p X' eze Contact Person: E-Mail Address: V7-/5v? &J7//k! , ,e Fax Number: 2e6 - 26 9 .513 Contractor Registration Number:_aejtA)Z Expiration Date: /00/z6etsics ARCHITECT OkitECORD - All plans must lieWf#t•stamped by Architect of Record ••• Company Name: Mailing Address: Contact Person: E-Mail Address: ENGINEER OF RECORD - All plons'inn4.be wet stamped by Engineer of ROOM . ".. • Company Name: Mailing Address: CG 6r) lieftri 25r, v n ue -Se Sie Zo/7 98O20 City State :Building Permit No.. tO 'Mechanical Plumbing/Gas Permit N • • Public Works Permit No Project No. (For office use only) • City State Zip Day Telephone: Fax Number: Zip Contact Person: 6ree 61il/en Day Telephone: 778 , 8.56C7 E-Mail Address: Fax Number: 7 78 55 Q: \ Applications \ Forms-Applications On Line\3-2006 - Permit Application:doe Revised: 9-2006 Page 1 of 6 bh BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 6 600 Existing Building Valuation: $ U Scope of Work (please provide detailed information): 5 here « »x115-}7 C)eeJ1/4-5 W/ pine VS - 3 % goal a V1- l; friS See. elSr15 tia)'a✓1 n O `S plates. I Will there be new rack storage? ❑ Yes Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Q:Wpplications \Forms - Applications On Line\3 -2006 - Permit Application.doc Revised' 9 -2006 bh • • If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: No If "yes ", explain: um*" hatre (o4err by s rv«ke El Other (specify) C e PC Y') FIRE PROTECTION /HAZARDOUS MATERIAL ❑ Sprinklers ❑ Automatic Fire Alarm None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material afety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing . Interior Remodel . _ Addition to ',Existing °,. ' Structure .. , New ., •.Type of • Construction per IBC Type of Occupancy per ' IBC I Floor 41 / C 7 ee 2 " Floor It/ 409 ^ � � 3` Floor "ti 009 Floors thru Basement Accessory Structure* Attached Garage Detached. Garage • Attached Carport' •°• ° { : . Detached. Carport Covered Deck Uncovered Deck : .. ''� ' ' BUILDING PERMIT INFORMATION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 6 600 Existing Building Valuation: $ U Scope of Work (please provide detailed information): 5 here « »x115-}7 C)eeJ1/4-5 W/ pine VS - 3 % goal a V1- l; friS See. elSr15 tia)'a✓1 n O `S plates. I Will there be new rack storage? ❑ Yes Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Q:Wpplications \Forms - Applications On Line\3 -2006 - Permit Application.doc Revised' 9 -2006 bh • • If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: No If "yes ", explain: um*" hatre (o4err by s rv«ke El Other (specify) C e PC Y') FIRE PROTECTION /HAZARDOUS MATERIAL ❑ Sprinklers ❑ Automatic Fire Alarm None Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material afety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOT-ES.;- Applicable to all � ,permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Ccnter to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE T ' U OR • ED AG IT: Signature: Print Name: 4/i Mailing Address: /02/ / Sf Av ), )e 5 — Date Application Accepted: Q:\Applications \Fors- Applications On Ltne\3 -2006 - Permit Application. doe Revised: 9 -2006 bh • • Date Application Expires: Date: q /0 8 Day Telephone: Cal- � I )4 pie,/7 City State Zip 34-07 Staff Initials: WIL Page 6 of 6 Receipt No.: R08 -03178 Payee: GRAN INC ACCOUNT ITEM LIST: Description BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE City of Tukwila Department ojfCommunity Development 6300 Southcenter l3oulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us TRANSACTION LIST: Type Method Descript:io Amount Payment Check 2352 1,651.20 000/322.100 000/345.830 000/386.904 RECEIPT Parcel No.: 3597000422 Permit Number: D08 -427 Address: 14901 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 09/08/2008 Applicant: HILLCREST APTS BLDG A Issue Date: Account Code Current Pmts Payment Amount: $1,651.20 Initials: WER Payment Date: 09/08/2008 01:59 PM User ID: 1655 Balance: $0.00 998.00 648.70 4.50 Total: $1,651.20 7065 09;00 T707 TOTAL 1651.20 doc: Receiot -06 Printed: 09 -08 -2008 Project: Type of Inspection: k; t 5ult Address: 0 - 1/\_1 - C_/ ), b� /�� 1&JF_ Date Called: Special Instructions: Date Wanted: -- l .. / t 0 - O a.m p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 1 lnsp4r: LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 3 ] INSPECTION RECORD Retain a copy with permit • �..er MAC ke r 'Date: D a S PERMIT NO. rR-, (206)431 -3670 Date: 1' to oS Project: 1 t (U err- / y ArT ° Type of spection: 7' I.. �l A Address: (, j_,,,,, -,.,, i 4v, A Date Called: ✓e. 7 Speci • I Instr ctions: Date Wanted: Requester: Phone N S -gip. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: j INSPECTION RECORD Retain a copy with permit Date: 'Date: DC8 4V) PERMIT NO. (206)431 -3670 COMMENTS: Type of inspection: spection: . e -/'a At , Al � i irAkre J ,{ tzk O jq t3 "lAJ" c , e I Date Called: A A Date Wanted: f ~ m ' - J r -0 p.m. r k s . -pJ S 40e SPI'ces - 1 Z Ss _ L)/\ r , it-t, t rva Dp.S dt ivt a^ ,t^e.-I . AL) J e 1 1)/1 J efr` 21% -- ri) LeAMS. p J) 1 7 , cyR 11Yr 1 --e-tv4 _-. 1 a 1 Pro'ect: t l ��r s � .u-� a�r.�c1 Type of inspection: spection: . e -/'a At , Al Address: U - 1- / 1 ,7 r U,_■i Av1 Date Called: Special Instructions: /� �1 V a. C-- 1 - 0 Date Wanted: f ~ m ' - J r -0 p.m. Requester: Phone No X25 - - 1 Z Ss CITY OF TUKWILA BUILDING DIVISION { INSPECTION RECORD T ' .1 Retain a copy with permit INSPECTION NO. PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 • El Approved per applicable codes. gerniEtions required prior to approval. Inspectot: t A �I\ (Date: 1 � {-- ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: J Projec :. /fief — Type of Insp ct ion: real 17Air address: :. c6 / nt /6 Date Called: Special Instructions: Date anted: ranted - /b — p&j a. m . Requester: Phone No: L // 5.~ % / - •2 INSPECTION"I E CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. 0 Corrections required prior to approval. 1/49._ COMMENTS: Receipt No.: INSPECTION RECORD 'Retain a copy with permit Da e: .� ) D- /6-0e ❑ $60.0 EINSPECTION F REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: nog-itz`7 PERMIT NO. 4 (206)431 -3670 Project: f -i � i ( 0 «s - 4 Ain A. Typ of Inspection: w e we S Date Called: ) c i oi Address 1 L1 CO l. 1\de ( -It abei Special Instructions: Date Wanted: a. m Requester: Phone No: • INSPECTION RECORD etain a copy with permit • INSPEEIT NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 Receipt No.: bot3 42 Date: / 'VA .., ... /0- iC 0 $6g ' i REINSPECTION FEE R QUIfD. Prior to inspection, fee must be pid - 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l 'Date: COMMENTS: Type of Inspection: Address /moo/ 7 //b", t» ; r ( f'--1 a i .f - Q c ( pp A ' etc / f o 1 1)3IN ,.f I I 6 6 f AO L. 1' e .I1, ., ic_i Ai c rt Nn c Ph 94/6/ c .. 0.5 ____ Ali r Project j Type of Inspection: Address /moo/ 7 //b", Date Called: Special Instructions: Date Wanted: ld- /d a. Requester: Ph 94/6/ c .. 0.5 ____ INSPECTION RECORD Retain a copy with permit INSPECTI N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ell Approved per applicable codes. orrections required prior to approval. Date: J J , Y ❑ $60.00 REINSPECTION FEE REQUIR D. Prior to inspection, f e must be paid at 6300 Southcenter Blvd., Suite 100. Call to scheduler inspection. Receipt No.: 'Date: DATE I - ZS -vg CERT. NO. 0 8t)7 - 6/ PROJECT fl /LC.Js r A tr beck AEPfi,1tZ LOCATION 14'R / I arek /OA a,) f1 1/C S . BLDG. PERMIT NO. I d A `/ OWNER WEATHER Licht /" Ote &C R / #J TEMP. AT AT AM PM ENGINEER ARCHITECT CONTRACTOR TO: ATTN: THE FOLLOWING WAS NOTED: Ta crsi Pia) P, te F2 Pi La NLI./M 2 t aq G IvL, 5 au�t -f 'T"o Na�T Ft MfrEca./ arLS .4. Si) Z a Mpg' 7 Lew; - 14 INT &At4L SL/ P tog., anti4 5 2 - / 1 10 18 PA/ , 1 Fro c MaM0 - F/N P ILE- PtitcEb if Sub -RA ) Vg. I" 1 O K L.E5 5 o F F a- Du a-10 IRET SSAL) Poiu PI LE *r 3- -e- = 13- Re F��RL. r 5 = 19: acEdsA-L 6 RE ^ ofe 7 20% REFUSAL 4r 6 19- P1te REVISED 1/02 CASCADE TESTING LABORATORY. INC. TESTING & INSPECTION 129 19 N.E. 126TH PLACE KIRKLANO.WASHINGTON 98034 (425) 823 -9800 EVERETT (425) 259 -0817 FIELD REPORT Los If,E0 u IL-D }/1e, (l�cc'a> Qdkc 111 s' c l,LAg% 4' BIZ 1 = 1 9 Z = ZD V TEST RESULTS APPLY ONLY TO THE ITEMS HEREIN TESTED. THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL WITH- OUT THE WRITTEN APPROVAL OF CASCADE TESTING LABORATORY. INC. 19 /6 zo =-1 12 INSPECTOR SIGNATURE SIGNED BY COPIES TO: r 741C »c(6-,or PREVIOUS REPORT No. FEe'T Ito bEfTt1 = RE F,./SAL 9 - ' - # 1 0 - /Y' _ 2sFa$A L I I - 1 _ PeFusA L No 58663' BLOC A 1 tag 2 AP! SL g /AsT A 53 /8 ,t iaY 6 116TWeEt1 Siericlos) qL ) S I 1 /'.ciarr OF 5arriuir Et lbR ?V 3 INSPECTOR(S), NAME(S) PRINTED ml G If �J L Melia V E E R RECEI OCT, 1. 2" aE °ELop ENT ACTIVITY NUMBER: D08 -427 DATE: 09 -08 -08 PROJECT NAME: HILLCREST APTS - BLDG A SITE ADDRESS: 14901 INTERURBAN AVE S X Original Plan Submittal Response to Correction Letter # DE PPARTMENTS: Budding Dlvlsi n Public Works Approved Notation: Documents/routing slip.doc 2-28-02 • PLAN P F � �VI EW % SLIP Fire Prevention _ Planning Division DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09 -09-08 Complete Incomplete ❑ Not Applicable ❑ Comments: Structural Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved with Conditions REVIEWER'S INITIALS: DATE: Response to Incomplete Letter # Revision # After Permit Issued n Permit Coordinator u DUE DATE: 10-07-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 AMERICAN STATES INS CO 6438691 07/31/ Z006 Until Cancelled $12,000.00 08/21/2006 1 DEVELOPERS SURETY a INDEM CO 855777C 07/31/2001 Until Cancelled 09/21/2006 $12,000.0008/06 /2001 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 FIREMANS FUND INS CO MXX80881746 11/01/2007 11/01/2008 $1,000,000.0012 /03/2007 7 COLONY INS CO GL163630 12/01/200612/01 /2007 $1,000,000.0003 /15/2007 Name Role Effective Date Expiration Date NAKATA, NELSON S PRESIIDENT 08/06/2001 Untitled Page General /Specialty Contractor • • A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GRAN INC UBI No. 601638695 Phone 2062834720 Status ACTIVE Address 1016 2ND AVE W License No. GRANI * *997NF Suite /Apt. License Type CONSTRUCTION CONTRACTOR City SEATTLE Effective Date 8/6/2001 State WA Expiration Date 10/16/2010 Zip 98119 Suspend Date County KING Previous License Business Type CORPORATION Next License Parent Company Associated License Specialty 1 GENERAL Specialty 2 UNUSED Business Owner Information Bond Information Insurance Information https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License = GRANT* *997NF Page 1 of 2 09/11/2008 BASE MATERIAL ANCHOR SIZE MINIMUM EMBEDMENT ALLOWABLE TENSION ALLOWABLE SHEAR CONC. 1/2" ROD 4 1/4" 2,838 1,935 CONC. 5/8" ROD 5" 4,320 • 3,025 CONC. 3/4" ROD 6 5/8" 5,356 4,355 CONC. . #4 BAR 4" 2,768 2,615 CONC. #5 BAR 5" 3,638 4,125 CONC. # BAR 7" 6,258 6,200 NOTES: 19 1. THE ABOVE VALUES ARE BASED ON THE HIL11 HIT HY 150 INJECTION ADHESIVE ANCHORING SYSTEM INSTALLED IN NORMAL WEIGHT CONCRETE, f c = 2500 PSI. CONTRACTOR MAY USE ENGINEER APPROVED EQUAL. 2. ROD STEEL IS A36, Fy=36 KSI Fu =58 KSI 3. REBAR STEEL IS A615, Fy=60 KSI Fu =90 KSI 4. ALLOWABLE SHEAR AND TENSION LOADS ARE THE LESSER OF THE BOND STRENGTH OR THE STEEL STRENGTH. 5. SPECIAL INSPECTION IS REQUIRED PRIOR TO GROUTING HOLES PER NE MANUFACTURER'S ICBO REPORT. 6. THE ABOVE VALUES ARE BASED ON AN EDGE DISTANCE GREATER THAN 12" AND A MINIMUM SPACING OF 14 ". CONTACT ENGINEER FOR OTHER CONDITIONS. f c = 2500 PSI PERIODIC DEVELOPMENT LENGTH LAP SPUCE BAR SIZE TENSION COMPRESSION TENSION COMPRESSION TOP BARS OTHER BARS ALL BARS TOP BARS OTHER BARS ALL BARS #3 24 18 9 30 23 12 #4 31 24 12 41 31 15 1200 39 30 15 51 39 19 47 36 18 61 47 23 # 68 53 21 89 68 27 # 78 60 24 102 78 30 NOTES: ARE IN INCHES. ARE CLASS B. ARE HORIZONTAL REINFORCEMENT PLACED SUCH NAT MORE OF CONCRETE IS CAST IN THE MEMBER BELOW THE BAR. 1. ALL LENGTHS 2. ALL LAP SPLICES 3. "TOP BARS" THAN 12 INCHES OPERATION `'°°- --- -CdNT: PERIODIC REMARKS---' ' '''' '' SOILS FOOTINGS 2500 PSI 0.45 PIPE PILING INSTALLATION N/A X 2500 PSI PIUNG REFUSAL VERIFICATION 5 SACK X ALL OTHER CONC. CONCRETE 0.45 5 SACK N/A ADHESIVE ANCHORS X 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR NOTE; ALL ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH 2006 IBC CHAPTER 17. SPECIAL INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY NE OWNER. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL RESULTS. ANY INSPECTION FAILING TO MEET NE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF NE DESIGN TEAM. 850 TYPE TY CONY OF f c MAXIMUM WATER /CEMENT RA110 MIN. CEMENT CONTENT PER CUBIC YARD MAXIMUM SHRINKAGE STRAIN FOOTINGS 2500 PSI 0.45 5 SACK N/A GRADE BEAMS 2500 PSI 0.45 5 SACK N/A ALL OTHER CONC. 2500 PSI 0.45 5 SACK N/A SIZE CLASSIFICATION NAIL SHANK 0 MIN. LENGTH 8d COMMON 0.1310 2 1/2" SHANK 10d COMMON 0.1480 3 SHANK 12d COMMON 0.1480 3 1/4" SHANK 16d COMMON 0.1620 3 1/2" SHANK - 6x AND LARGER BEAMS AND STRINGERS SIZE CLASSIFICATION SPECIES GRADE STUD Fb (PSI) 776 (REP) Fc (PSI) 800 LIGHT FRAMING (STUDS) HEM -AR 2x JOISTS AND PLANKS HEM -FIR #2 978 (REP) - PLATES AND BLOCKING HEM -FIR # 850 - 6x AND LARGER BEAMS AND STRINGERS DOUG -FIR #2 875 - 4x AND SMALLER BEAMS AND STRINGERS HEM -FIR # 850 ALL POSTS AND TIMBERS DOUG -FIR #1 1200 1000 STRUCTURAL NOTES (THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS). CODE ALL MATERIALS, WORKMANSHIP, DESIGN AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS AND THE INTERNATIONAL BUILDING CODE (IBC), 2006 EDITION. SPECIFICATIONS AND STANDARDS WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. DESIGN LOADS DEAD LOADS: ROOF FLOOR DECK 15 PSF 12 PSF 19 PSF LIVE LOADS: ROOF (SNOW LOAD) 25 PSF RESIDENTIAL 40 PSF (LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.9). QUALITY ASSURANCE PLAN A QUALITY ASSURANCE PLAN SHALL BE IMPLEMENTED TO VERIFY INSPECTIONS AND OBSERVATIONS ARE COMPLETED AS REQUIRED FOR THE LATERAL FORCE RESISTING SYSTEMS IN ACCORDANCE WITH SECTIONS 1705 AND 1706 OF NE IBC. SUPPORTING DOCUMENTATION SHALL BE PROVIDED BY NE CONTRACTOR TO NE BUILDING OFFICIAL TO ACKNOWLEDGE THEIR AWARENESS OF THESE REQUIREMENTS. FREQUENCY AND DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEE• D BUILDING OFFICIAL 35 PCF + ANY APPLICABLE SURCHARGE 35 PCF + 10 PSF * WALL HEIGHT LATERAL EARN PRESSURE: UNRESTRAINED: RESTRAINED: FOUNDATIONS: PIN PILES SOILS REPORT: NOT AVAILABLE AT TIME OF DESIGN ALLOWABLE 2 "0 PILE CAPACITY: 4000 LBS PASSIVE EARTH PRESSURE: 300 PCF 'f euail'GoNS oPif esav iNitaina.1 IMPORTED STRUCTURAL FILL AND BACKFILL MATERIAL SHOULD CONSIST OF CLEAN, WELL GRADED GRANULAR MATERIAL FREE OF DEBRIS OR ORGANICS WITH A MINIMUM PARTICLE DIAMETER OF THREE INCHES AND NO MORE THAN 10% FINES (PASSING THE #200 SIEVE). FILL AND BACKFILL MATERIAL SHOULD BE PLACED IN LEVEL LIFTS NOT EXCEEDING TWELVE (12 ") INCHES IN LOOSE THICKNESS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AS DETERMINED BY ASTM TEST METHOD D1557 -00. BACKFILL BEHIND ALL RETAINING WALLS WITH WELL- DRAINING, GRANULAR ALL AND PROVIDE FOR SUBSURFACE DRAINAGE. PROVIDE DAMPPROOFING AT EXTERIOR FACE OF ALL FOUNDATION WALLS EXPOSED TO EARTH PER ARCHITECTURAL SPECIFICATIONS. 2.0 PIPE PIUNG INSTALLATION SCH. 80 PIPE SHALL CONFORM TO ASTM A35, FY = 35 KSI PIPE PILING SHALL BE DRIVEN INTO THE SUBGRADE TO A POINT OF REFUSAL BY MEANS OF A PNEUMATIC HAMMER OR OTHER SIMILAR HYDRAULIC HAMMER SYSTEM. THE PNEUMATIC HAMMER SHOULD WEIGH AT LEAST 140 POUNDS. REFUSAL SHALL BE DEFINED AS 1" OR LESS OF PENETRATION DURING 1 MINUTE OF SUSTAINED DRIVING. PIPE SECTIONS SHALL BE CONNECTED WIN INTERNAL SLIP COUPUNGS. THE CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1 -800- 424 -5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. IT IS THE SOLE RESPONSIBIUTY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY ALL UTILITIES WHICH MAY BE AFFECTED BY NE IMPLEMENTATION OF THESE DRAWINGS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY AND ALL DAMAGE TO UNDERGROUND U11U11ES RESULTING FROM THEIR OPERATION. CONCRETE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH SECTION 1905 OF THE IBC AND NE AMERICAN CONCRETE INSTITUTE'S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACT 301). ALL CONCRETE SHALL BE STONE- AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS PER CUBIC FOOT. CONCRETE STRENGTHS AT 28 DAYS (f c) AND MIX CRITERIA SHALL BE AS FOLLOWS: THE MINIMUM AMOUNT OF CEMENT USTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. NE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER, AND ADMIXTURES AS WELL AS NE WATER - CEMENT RATIO, SLUMP, CONCRETE YIELD, AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH IBC SECTION 1905. ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR - ENTRAINED IN ACCORDANCE WITH IBC TABLE 1904.2.1 FOR MODERATE EXPOSURE CONDITION. REINFORCING STEEL REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy = 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WIN ASTM A615 MAY BE WELDED IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE SUBMITTED. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. PROVIDE WELDED WIRE FABRIC IN SHEETS NOT ROLLS. LAP WELDED WIRE FABRIC 12" AT SIDES AND ENDS. REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH SP66(94) AND ACI 318R -O2. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE PER SCHEDULE. MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON NE DRAWINGS, SHALL BE BY AN ICBO APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE INSTALLED IN ACCORDANCE WIN THE MANUFACTURER'S RECOMMENDATIONS. REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET- SETTING EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. REFER TO IBC SECTION 1907 FOR OTHER . REINFORCING STEEL REQUIREMENTS. MINIMUM LAPS AND EMBEDMENT . UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED BELOW: CONCRETE COVER ON REINFORCING CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: CONCRETE EXPOSED TO EARN AND WEATHER: #6 BARS AND LARGER #5 BARS AND SMALLER CONCRETE NOT EXPOSED TO EARN OR WEATHER: SLABS, WALLS AND JOISTS COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 3" 2" 1 1/2" 3/4" 1.1 /2" A HAVE ANCHORS CONCRETE GENERAL NOTES VERTICAL BARS SHALL START FROM TOP OF FOOTING. HORIZONTAL BARS SHALL START A DISTANCE OF 1/2 THE NORMAL BAR SPACING FROM TOP OF FOOTING AND TOP OF FRAMED SLABS. IN ADDITION, THERE SHALL BE A HORIZONTAL BAR AT A MAXIMUM OF 3 INCHES FROM TOP OF WALL AND BOTTOM OF FRAMED SLABS. PROVIDE CORNER BARS TO MATCH THE HORIZONTAL REINFORCING: WITH TENSION LAP SPLICE AT EACH SIDE PER TABLE, OR BEND ONE SIDE OVER TO PROVIDE TENSION LAP. PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF NOT MORE THAN 400 SQUARE FEET EACH. AREAS TO BE AS SQUARE AS PRACTICAL AND HAVE NO ACUTE ANGLES. JOINT LOCATIONS TO BE APPROVED BY THE ARCHITECT. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED BEYOND JOINT. SEE ARCHITECTURAL DRAWINGS AND MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF OPENINGS IN CONCRETE WALLS, FLOORS AND ROOF. UNLESS INDICATED OTHERWISE, REINFORCE AROUND OPENINGS GREATER THAN 12" IN EITHER DIRECTION WITH (2) -5 EACH SIDE AND (1) -#5 x 4' -0" DIAGONAL AT EACH CORNER. EXTEND BARS 2'-0 BEYOND EDGE OF OPENING. IF 2'-0" IS. UNAVAILABLE, EXTEND AS FAR AS POSSIBLE AND HOOK. HOOK ALL REINFORCING INTERRUPTED BY OPENINGS. BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS NOTED. LUMBER ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: REFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. ALL LUMBER IN CONTACT WITH CONCRETE, MASONRY, OR WITHIN 8" OF SOIL SHALL BE PRESSURE - TREATED. jEPABATE PERMIT REQUIRED FOR V Mechanical M Electrical 11,Iumbing tif Gas Piping City of Tukwila ; iii e ,Di -fG DIVISION b. Oa: eul ALL NAILS SHALL CONFORM TO NE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER IBC TABLE 2304.9.1 NAILING SCHEDULE. ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: 10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING MEMBERS MAY BE NAILED WITH 16d SINKERS (0.131"0 x 3-1/4"), BUT ONLY 16d COMMON NAILS SHALL BE USED WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR NE SHANK AND THREADED PORTIONS PER NDS 9.1.2. CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH NE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY NE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE -HALF OF THE NAILS, SCREWS, OR BOLTS IN EACH MEMBER. INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. GENERAL STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. CONTRACTOR TO SEE ARCHITECTURAL, CIVIL, ELECTRICAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF PIPE, ,VENT, DUCT AND OTHER OPENINGS AND DETAILS NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. CONTRACTOR- INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. CUD'S COMPLIPAC APPROVED SEP 11 2008 O� y pf Tuk \NW BUILDINUMIS FILE ; O Y Permit No PI r review approval Is subject to ens and omissions. � F,ppraval of construction documents does not authorize Receipt the violation of any adopted c ode or ordinance. of approved Field Copy and is acknowledged: B City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope o work without prior approval Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pla rev e' 1 fees. .� T0& 917 RECEWED SEP 0 8 2008 PERMIT CENTER c ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778 -8500 FAX (425) 778 -5536 w I- 0 0 CO r7 0 DESIGN: JMS DRAWN: MGV CHECK: GAG JOB NO: 07148.12 DATE: 03/18/08 V) W F- 0 z SHEET: S1.1 - J 1 a _J PARTIAL FOUNDATION PLAN (TYPE A) SCALE: 1/4* = 1' -0" 6x6 HF# 2 P.T. I•I „ 6x8 DF 11111_. L L 2' -0" x 2' -0" FTG W/ (2) - #4 BOT. EA WAY, TYP. U.N.O. L__J 2 "0 PILE TYP. EX. SLAB ON GRADE SAW CUT EX. CONC. SLAB, TYP. L J 6x8 DF #1 P.T. I , 1 ' -0 2' - 6 " TYP. , TYP. 1'-6" x 4' -0" FTG. W/ (2) - #4 CONT. TOP& BOT. 7 O 16 O.C. 2 PARTIAL FONDATION PLAN (TYPE B SCALE: 1/4 = 1 ' -0 1 EX. 2x10 JOISTS O 16" O.C. J -EX. T TO JOTSTS 16" O.C. EX. 2x10 JOISTS r I•I • I•' -0" TYP. - 6x6 HF# 2 P.T. 6x8 DF I1 P.T. L r L r L EX. 2x10 JOISTS O 16* O.C. EX. 2 1 JETS O 16" O.C. O 16A O.C. LJ EX. 2x10 JO STS Lm EX. SLAB ON GRADE 1' -6" x 7' -0" GRADE BEAM W/ (2) - #4 CONT. TOP & BOT. LJ 2 "0 PIN PILE, TYP. 6x8 DF #1 P.T. 1' -6" x 4' -0" FTG. W/ (2) - #4 CONT. TOP & BOT. 1' -6" x 1-0» GRADE BEAM -J W/ (2) -#4 CONT. TOP & BOT. 1 J L • 1 •i J r J 1 J r 6x6 HF# 2 P.T. 6x8 D 1 P.T TYP. 1' -0" LJ EX. SLAB ON GRADE EX 0 L! 6x8 DF #1 P X 1'-0" TYP. 2'x2'FTG (2) -#4 BOT. EA. WAY 1' -6" x (-0" FTC. W/ (2) - #4 CONT. TOP & BOT. EX. 2x10 JOISTS 0 16" O.C. 2x10 • JOI 16" O.C. EX. 2x10 JOISTS 0 16" O.C. J I•I [COTE: CONTRACTOR SHALL TEMP. SHORE & SUPPORT DECKS DURING CONSTRUCTION. SIMPSON A24 EA. SIDE POST. W/ 1/2"0 MEN SCREW INTO CONCRETE & 1 /2 "0 LAG SCREW INTO POST. EX. CONC. TOPPING SLAB SECTION SCALE: 1" = 1' -0" ` _ffl[E l EX. JOIST PER PLAN SIMPSON AB46 P/T POST PER PLAN A U re) (3) - #4 BARS PER PILE °° OR 6" SQ. o � SIZE & REINF. PER PLAN SIZE & REINF. PER PLAN BEAM PER PLAN SIMPSON AC6 COLUMN CAP EA. SIDE SIMPSON AC6 POST CAP EA. SIDE 7 -- COL PER PLAN SIMPSON AB46 POST BASE EX. CONC. TOPPING SLAB EX. JOIST PER PLAN GRADE BEAM PER PLAN EX. CONC. SLAB UNDISTUBED SOIL T.O. GRADE ELEV. (3) -#4 BARS PER PILE 8" PIPE PILING PER PLANS & STRUCT. NOTES - STEEL PIPE PILING PER PLAN AND STRUCTURAL NOTES SECTION KL VitVVLO I CODE COMPLIANCE APPROVED SEP 1 1 2003 City Of Tukwila BUILDING DIVISION 1D OB L1Z7 RECEIVED SEP 0 8 20 PEHIVIII CENTER I= • ENGINEERING /6/6g EXPIRES: 9/5/2009 1 I- 0 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778 -8500 FAX (425) 778 -5536 2 DESIGN: JMS DRAWN: MGV CHECK: GAG JOB NO: 071 48.1 2 DATE: 03/18/08 w Q z Q z 0 (f) aQ Z t.t.l o 0 CS SHEET: S2.1 s VRFY /PROVIDE 6x6 HF# 2 P.T. 6x8 DF #1 P.T. SCALE 1/4' = 1' -O' PARTIAL 2ND & 3RD FLOOR PLAN EX. 2x10 JOISTS O 16" O.C. EX. 2x10 JOIST O 16" O.C. EX. 2x10 JOISTS O 16 O.C. EX. 2x10 JOISTS O 16 O.C. O 16" O.C. EX. 2x10 J O 16 O.C. L ISIS VRFY /PROVIDE 6x6 HF# 2 P.T. CENTER TYP. L 6x8 D 1 P.T. EX. 2x10 JOISTS O 16" O.C. �c. 0 CENTER TYP. 2x10 JOIS 6" O.C. EX. 2x10 JOISTS O 16 O.C. 0 CONTRACTOR SHALL TEMP. SHORE & SUPPORT DECKS DURING CONSTRUCTION. CODE COMPLIANCE APPROVE SEP V! Cif �+Tukvilda • BuIloI NG rMSIO.. RECEIVED SEP 08 2008 PERMIT CENTER c ENGINEERING 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778 -8500 FAX (425) 778 -5536 ahtios IEWIRES: 9/5/2009 I w F- 0 2 I- CC W CL Co co M DDB Li 27 SHEET S2.2 DESIGN: JMS DRAWN: MGV CHECK: GAG JOB NO: 07148.12 DATE: 03/18/08 s v) z LL z ct 0 w 0