Loading...
HomeMy WebLinkAboutPermit D08-439 - ABU-BAKR ISLAMIC CENTER - TENANT IMPROVEMENTABU -BAKR ISLAMIC CENTER 14101 TUKWILA INTERNATIONAL BL D08 -439 City Tukwila Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Issue Date: 03/02/2009 Suite No: Permit Expires On: 08/29/2009 Tenant: Name: ABU -BAKR ISLAMIC CENTER Address: 14101 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: ABU -BAKR ISLAMIC CENTER OF Address: PO BOX 18067 , SEATTLE WA 98118 Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: YOUNG KIM Address: 3828 FOURTH AVE S #7 , SEATTLE WA 98134 Phone: 206 - 355 -9686 Contractor: Name: SEATTLE BUILDERS INC Address: 9707 18 AV CT S #S -3 , TACOMA WA 98444 Phone: 206 375 -8160 Contractor License No: SEATTBI922QQ doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** • Expiration Date: 11/18/2010 DESCRIPTION OF WORK: CLEAN UP AND ADD OFFICES, BATHROOMS. REPAIR PLUMBING FIXTURES, INTERIOR WALLS AND DOORS. PUBLIC WORKS ACTIVITIES INCLUDE STREET USE, FOG LINE STRIPING ALONG NORTH SIDE OF S. 141st STREET and UPGRADE OF FIRE DEPARTMENT CONNECTION (FDC) WITH KNOX LOCK. Value of Construction: $30,000.00 Fees Collected: $13,852.05 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: V -B Occupancy per IBC: 0005 D08 -439 Printed: 03 -02 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N I hereby certify that I have read and e governing this work will be complied doc: IBC -10/06 City ofTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i Permit Number: D08 - 439 Issue Date: 03/02/2009 Permit Expires On: 08/29/2009 Permit Center Authorized Signature: 1 , (V 1 . Date: The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. am authorized to sign and obtain this development permit. Signature: Date: ` 1— Print Name: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -439 Printed: 03 -02 -2009 1: ** *BUILDING DEPARTMENT CONDITIONS * ** b City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS • Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 09/19/2008 Tenant: ABU -BAKR ISLAMIC CENTER Issue Date: 03/02/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or doc: Cond -10/06 D08 -439 Printed: 03 -02 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 20: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 21: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 22: Each door in a means of egress from an occupancy of Group A or E having an occupant load of 50 or more and any Group H occupancy shall not be provided with latch or lock unless it is panic hardware or fire exit panic hardware on rated fire doors. (IFC 1008.1.9) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Doors shall swing in direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. (IFC 1008.1.2) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having doc: Cond -10/06 D08 -439 Printed: 03 -02 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 30: Every room or space that is an assembly occupancy shall have the occupancy load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible permanent design and shall be maintained by the owner or authorized agent. (IFC 1004.3) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 34: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 35: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 36: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 37: Fire Department lock boxes shall be provided for access to all fire alarm panels and sprinkler risers. The appropriate key(s) for access shall be placed in the lockbox. Lockbox order forms must be obtained from the Tukwila Fire Department. The lockbox should be mounted so that it is readily visible and not over 60 inches high. (City Ordinance #2051) 38: The Tukwila Fire Department has changed keybox manufacturers, from Supra to Knox. Install a fire department Knox keybox. Contact the Tukwila Fire Prevention Office at 206 - 575 -4407 for ordering information. 39: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 40: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth doc: Cond -10/06 D08 -439 Printed: 03 -02 -2009 City of Tukwila in Table No. 803.5 of the International Building Code. 47: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 50: ** *PLANNING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 41: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 42: In occupancies of Groups A, E, I and R -1 and dormitories in Group R -2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall be flame resistant in accordance with NFPA 701 or be noncombustible. Where required to be flame resistant, decorative materials shall be tested by an approved agency and pass Test 1, as described in NFPA 701, or such materials shall be noncombustible. Reports of test results shall be prepared in accordance with NFPA 701 and furnished to the fire code official upon request. (IFC 805.1, 805.2) 43: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 44: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 45: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 46: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 48: Minimum 48 hours in advance applicant shall call (206) 433 -0179 to schedule a Public Works pre - construction meeting. The applicant must notify the City Project Inspector at (206)433 -0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. Exact fog line location shall be determined and approved in the field by the Public Works Project Inspector based on temporary pavement marking. Work affecting traffic flows shall be closely coordinated with the City Public Works project Inspector. Traffic Control Plan shall be submited to the inspector for prior approval. Contractor performing work inside the City Right of Way shall obtain a Tukwila Business License from Tukwila City Clerks office at 206 433 -1854 prior to any work in the Right of Way. Applicant shall execute a Right of Way Hold Harmless Agreement prior to permit issue. Applicant shall submit to Public Works a current copy of Insurance Certificate naming City of Tukwila as additional insured . Appli 49: Applicant shall replace existing siameese or Stortz Fire Department Connection (FDC) with a 5" Locking Storz Cap(s) manufactured by Knox. Please contact Tukwila Fire Department at (206) 575 -4404 to obtain and order form, since they must be ordered through Tukwila Fire Department office. They can also be ordered from the Knox website after obtaining the code from the Fire Department. 51: All site improvements including striping and landscaping proposed with this project shall be completed prior to final occupancy being issued by the City. No worship services or other functions are allowed to occur on the property until a certificate of occupancy is issued by the City. D08 -439 Printed: 03 -02 -2009 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 52: No modifications shall be made the approved landscaping plant without prior approval of the City. 53: Prior to occupancy the Mosque shall provide a minimum of 114 parking spaces. The parking area shall comply with the design standards specified in TMC 18.56. Since the required number of parking stalls will be located over two tax parcels the applicant shall establish and have recorded a Shared and Covenant Parking Agreement between the Mosque property and the Pawn X -Change property. The language of the Shared and Covenant Parking Agreement shall be approved by the City and shall be consistent with TMC 18.56.070. The Shared and Covenant Parking Agreement shall be recorded with King County Department of Records prior to final occupancy of the building. The applicant could also choose to combine the two parcels through a lot consolidation process. 54: Prior to the certificate of occupancy being issued for the proposed mosque the applicant shall provide a lighting plan which demonstrates compliance with the lightings standards of Tukwila International Blvd Design Manual. 55: A separate sign permit is required for all outdoor signs on the site. 56: The applicant shall comply with all requirements contained in the Department of Community Development's Notice of Decision regarding Parking issued on September 10, 2008. doc: Cond -10/06 * *continued on next page ** D08 -439 Printed: 03 -02 -2009 Signature: Print Name: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D08 -439 Date: • 0 / ordinances governing or local laws regulating Printed: 03 -02 -2009 King Co Assessor's Tax No.: Re ( 000 D () 5 Site Address: I l ICI rU K-vv q- 4 IN r A 'N/k L BLVD Suite Number: Floor: Tenant Name: ANA " E,14-1Z 15 LA MI Ci reg_.Dr" WA-- New Tenant: / Z.:. Yes 0 ..No Property Owners Name: JA-1 U Pi A Ail Ail 4 I- JA Y 1- t_ A f2 Mailing Address: 1 X1 5 -1 1 (ANN / 's V &- 14.E r Nj VpJ Name: Mailing Address: Mail Address: Company Name: 1 ei) Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Yo r\l( k I M OL Mailing Address: City Day Telephone: Fax Number: 1J v P.0 H ire- Kt= 3q 2 4 11- A Va s - �7 City State Zip Contact Person: ' WN 14/ Day Telephone: ®G f 353 — `l k E -Mail Address: k n w ti hcYl cor ,.Fax Number: 2 C4;) &2.9 — 03 01 Q:\Applications\Forms- Applications On Linel3 -2006 - Permit Applieation.doc Revised: 9 -2006 bh City Expiration Date: State Day Telephone: 2 0 6) 3 5 5 •— . ` 6 6 City State Zip Fax Number: w6) 6 Z 1 4 "3 G State ci t C . Zip Zip Company Name: ' 4ailing Address: Zip Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Page I of 6 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Will there be a change in use? ❑ Yes Q:\Applications\Fonns- Applications On Lined -2006 - Permit Application.doc Revised: 9 -2006 bh i ebb Existing Building Valuation: $ 2 M I L (-lean L ADD OFFICES . PA -i`1-1 teoo.mS gel* ID FLWc'1Bl (, r 1 — utzes iNT u)A- - 14 A RD Doop..,s Will there be new rack storage? 0.... Yes No If yes, a separate permit and plan submittal will be required. Provide All:Biuildi stpiFt) ng ..' • 13.2401 erior. Rem � , 2- C., idt to rtsting ttt cture V- a Type o f occupancy per A3 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Scope of Work (please provide detailed information): (Alecto (M , A -w Dpi c &s A-t f3 pLi,{vt ?ltJ 62 xtURES, (1Jr 1)JM,( " A-ND Pleaserefento PtibliC #1�for fees ?and'esfiinateesti'eet: Water District ri :..Tukwila 0... Water District #125 ❑ ...Water Availability Provided Call before you Dig: 1- 800 -424 -5555 ❑ .. Highline Sewer District Tukwila ❑... ValVue ❑ .. Renton 011...Sewer Use Certificate 0... Sewer Availability Provided MS, 12E-_1,24i rL 12S ❑ ...Renton ❑...Seattle r' Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Ri -of -wa Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill FINANCE INFORMATION Fire Line Size at Property Line cubic yards cubic yards ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ...Water Main Extension Public ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ft ff WO # WO # WO # Private Private ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use - Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage Number of Public Fire Hydrant(s) - ❑ ...Water ❑ ... Sewer ❑ ...Sewage Treatment Monthly Service Billing to: ❑...Traffic Impact Analysis ❑...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Mailing Address: Q:Wpplicationaomis- Applications On Line' -2006 - Permit Applica ion.doc Revised: 9 -2006 bh City Day Telephone: City State State Zip Zip Page 3 of 6 'v.:00 41K • : Qty+. 'giii e, � �rYL •� o � ;.,. , . i . , ;I�}i�„�ype� �(�ry it : : r: Boiler /GoQp�a °,�; Furnace<100K BTU Air Handling Unit > ;000 CFM Fire Damper 0 -3 HP /100,000 BTU E Furnace>100K BTU Evaporator Coo i` i er 3 -15 HP/500,000 BTU Floor Furnace Ventilation F Connected to Single D Th =•. ostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilate System Wo. • : Stove 30-50 HP/1,750,000 BTU Appliance Vent Hoo d Duct Emergen Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System cinerator - Domestic Other Meehan Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/md . MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Mechanical wo (contractor's bid price): $ Scope of Work (please provide ' etailed information): Use: Residential: New ....CI lacement .... D Commercial: New .... Rep cement .... 0 Fuel Type: Electric fl Gas .... Indicate type of mechanical work being installed and the Q: Applications\Fomu- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh ty below: City Day Telephone: Fax Number: State rip Expiration Date: Page 4 of 6 � IO r PP calerto ittp r p �;T L A 1N T'E :{� � z s� aPl '' .�!C' � } 1� ` �; ti r. -' R ':. a;• : �XS'.,,.� .,... •�.:tt: :cc � fv':F Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitatirl Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). , I HEREBY CERTIFY THAT I HAVE O� �TA ET OF THIS AND AM AKNOW ORIZED TO APPLY � TRUE THIS PERMIT. PENALTY OF PERJURY BY THE LAW BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: N(0 U (O ! I M Mailing Address: Q:\ pplicationsWortnrApplications On Line U-2036 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: 2at1ie City Date: 206 3 55 - 9 651 State 5113 Zip • Date Application Accepted: 9 _(q_ ©S Date Application Expires: . . (q _ cot Staff Initials: Go f Page 6 of 6 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: : ailing Address: Contact Person: E -Mail Address: Contractor Registration Number. Valuation of Plumbing ork (contractor's bid price): $ j 3, 000 — Valuation of Gas Piping (contractor's bid price): $ Scope of Work (please provi detailed information): le •i- I re- I hl(, ' L-U M !; 1 I\l gPD I,t-w Building Use (per Int'l Building Code): A - 3 l (p i Occupancy (per Int'l Building Code): Utility Purveyor: Water: LI r t e t7 rtt : W f L. A Indicate type of plumbing fixtures and/or:gas piping ou . ,- is be x.- FUtfure TU'P.O.OVAItI thtub or combination oath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain • Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor drain Shower, single d trap Lavatory Rain wat drain ( Repa Pip 0' 1Applications Forms -Applications .On Line\3 -2006 - Pemit Application.doc Revised: 9-2006 bb system – per ide building) or alteration of water and/or water treating pment � n !Ts' xtu Sewer: installed and the quantity below: 130.0gb;Ty Wash fountain Receptor, indirect waste inks als Closet Water'. .ter and/or vent Repair or of drainage piping eration vent city Day Telephone: Fax Number: Expiration Date: C4 a LA- 10 S A. T(.4 RCS Si s LE t M Gas piping outlets Additional medical gas inlets/outlets – six or more Medical gas piping system serving one to five inlets/outlets for specific gas Zip PAL Page 5 of 6 Receipt No.: R09 -01165 Initials: User ID: WER 1655 Payee: ALI AHMED Payment Cash Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES e City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: 03/02/2009 TRANSACTION LIST: Type Method Descriptio Amount 60.00 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 • Payment Amount: $60.00 Payment Date: 07/24/2009 04:14 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -24 -2009 Receipt No.: R09 -00924 Initials: User ID: Payee: WER 1655 ALI Payment Cash Authorization No. ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: 03/02/2009 TRANSACTION LIST: Type Method Descriptio Amount 60.00 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 Payment Amount: $60.00 Payment Date: 06/19/2009 10:55 AM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -19 -2009 Receipt No.: R09 -00510 Initials: WER User ID: 1655 Payee: ABU -BAKR ISLAMIC CENTER 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 60.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: ISSUED Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: 03/02/2009 Account Code Current Pmts 000/345.830 60.00 Total: $60.00 Payment Amount: $60.00 Payment Date: 03/31/2009 02:46 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 03 -31 -2009 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: Receipt No.: R09 -00344 Payment Amount: $11,483.50 Initials: LAW Payment Date: 02/27/2009 04:17 PM User ID: 1632 Balance: $0.00 Payee: ABU -BAKR ISLAMIC CENTER OF WA TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5508 11,483.50 ACCOUNT ITEM LIST: Description BUILDING - NONRES PW BASE APPLICATION FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW STATE BUILDING SURCHARGE TRAFFIC MITIGATION FEES Account Code Current Pmts 000/322.100 000/322.100 000/342.400 000/345.830 640.237.114 104.367.120 Total: $11,483.50 0906101-1 0223 03/02/2009 001 101 Di_[•' Perri Plus - General Fund $867.00 567.00N. $ 1 0) 250.00/ 25.00 25.00 4.50 10,612.00 doc: Receiot -06 Printed: 02 -27 -2009 Receipt No.: R08 -03989 Initials: LAW User ID: 1632 ACCOUNT ITEM LIST: Description BONDS /DEPOSITS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payee: ABU -BAKR MOSQUE OF WASHINGTON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1524 2,000.00 RECEIPT Account Code Current Pmts 000/386.908 2,000.00 Total: $2,000.00 Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUICW Status: APPROVED Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: Payment Amount: $2,000.00 Payment Date: 12/30/2008 12:28 PM Balance: $11,483.50 0907 12/30 9707 TOTAL 2000.00 doc: Receipt-06 Printed: 12 -30 -2008 p Receipt No.: R08 -03308 Initials: WER User ID: 1655 Payee: ABU -BAKR MOSQUE ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 1610000125 Permit Number: D08 -439 Address: 14101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 09/19/2008 Applicant: ABU -BAKR ISLAMIC CENTER Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1087 368.55 Account Code Current Pmts 000/345.830 368.55 Total: $368.55 Payment Amount: $368.55 Payment Date: 09/19/2008 03:19 PM Balance: $571.50 r • 7.'r2 y -,r.- T .' T l ' 6 doc: Receipt-06 Printed: 09 -19 -2008 Project: y .821_'36//R.2:stA/O'C Type of Inspection: Fi Al i9 I Address: /'- v/ - FT 5 Date Called: Special Instructions: Date Wanted: 9- 23 - 05 p.m. Requester: Phone No: a2.0‘-2 6 / - 4 /9s14, !0 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: INSPECTION RECORD Retain a copy with permit - t 'r 0.14 Ctf,' > L± / F:iJ A D . te: • - 2.3 REINSPECTION FEE R: QUIRED. • rior to inspection, fee ust be t 6300 Southcenter Blvd , Suite 100. Call to schedule reinspection. Rec =ip No.: (Date: COMMENTS: p 0 / f t 4 6) t, 41 7 /_ i o e,l I sg ie / ? i n 1 2 , A , 9 C Q44✓r -epi, 1 ',(2.) Ao 4-,?4„,,) 76 3 RatJ61s6 4 3)9 -S i 1 lJ 1902>~'4 a 4i" 8l#U'L. 40,0, i b i s has 4t ), _.(9 ir►z+av " i 5 I Vof A . d . 7'/i4 ) .2 s/o / ■TAile- 1 44)0 Re- 7r9,mot/A 6c, 4 r / I /Z , rr /e /r5 ( . 7 /) e •v 2 -/ 1 / , 4A1.) k, FOOS •;.W arrl i1 d) 6J 1*'evielf 7 iI(sN5 Id 4;), S / pe r Pm awin / /0 d,' ('/4 3/ T 4I G v g) / e 0.1 1 14 , 4 tcy aie-ndirnek - icifi/e'Vr- / - ZIA (/ -S �'l) /C, �/ \ Project: Ago gA Est , c_ Type of s pectio ' , n I Q u + Address: _...� , fl Date Called: Special Instructions: Date Wanted: a.m Requester: Phone No: 7.f) -33/ - /Gl i• o g -431 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 El Approved per applicable codes. sp tor: Receipt No.: E REQUIRE . P = Corrections required prior to approval. 3 Date: Date: $60.00 REINSPECTION rior to inspection, fee must be paid at 6300 Southcente r vd. Suit 100. Call to schedule reinspection. Pro'ez U 3s ^I! Type of Inspection: p c`�N� Chit, X5 Ad ress: )41 r) Date Called: Special Instructions: Date Wanted: �3 /2s /0 5 ri 0 Requeste : Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 f›e - yi PERMIT NO. 14 1— (206)431 -3670 0 Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: fr,, (A gay " - Lis 14-i4Ai wS5 i - 3 c-► -��i a,/ �r-� kA tJ�- � S 60-n4 v oiri tGr: I Date � 6 .00 REINSPECTION FEE REOUII ED. Prior to inspection, fee must be d at 6300 Southce er Blvd., Suite 100. Call to schedule reinspection. Recei . t No.: 'Date: COMMENTS. i p. r etr n • ype of Inspection: �� ?c e. -Ay■ ..1)(/ e A i S. -- A T AC - l( IeJJ ( ' Aer.4 5p/ f -er 1.)-JI J r l t A. P p . 60 S 6 511.------7 4 4 2 -D .0 '\ Special Instructions: ., � ` n e A (l ! ' �l . f Date Wanted: )i -- Ae'P I-7r r: , a p.m. 14 . n cP, elleALL fk e t 1 9 Gad P4 A n e. t kePl 41. C ddt� , (1, e- j � uJ n . f .P if 11I t 'dA i.► - Pro'ect: pp p 1 / ype of Inspection: 4 j A Address: (4i E Datelle Special Instructions: Date Wanted: )i -- 14 i� 7 , a p.m. Requester: Phone No: i . INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R ' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. 0,A4C Inspfctor: Date: . $60.'00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENT Qr 7 - 0 new FMe. z1e..A C L,' 1A ALAS Pc_rJA c o4r/G c f 51Ik1I /3L r re P�r Me r t Nike* v:s A • EA S a c a r s L A-1 , .+ ri'A i/ S e i -i-I Mort Co i7Y F. ` el Jt c 1 YID F r M;'1; A..... An 1 c.,4 -A, (E__ tri,./ 0ky i\o,,.Y'" 61 TI AIR_ W A ` (An (-? 4 r Si, ( AJM (eJeJ MJie f-k�TJ 1.,‘�.je (C' l ,u.fp.4 Lis r c war 4 1 01_, 5 (2 rty,, „A MA,,. uCc_, -,h - /Jit4l ---` S i /' A k rn pit, ; "- A l c c-is: to s. J 1 ;n- b 't A` sq. g- J am " 11 ` 4 Nt�A414- ,Jars f aA ea ' (r � .s _ Project: 6� Type o Inspection: C re - 3a : ( A '/4 ! Elio f Address: T om-,,- 2 Date Called: Special Instructions: _ ^ eOP 'iYv(..At 0 6Dftes e �P S (� k.e. 1 L) / C� . . _ 5 % )- e 3 0 u k /AA (j �� � 5 AM C t.s:4 AS v� Date Wanted: & - /4" Cl ca p.m. Requester: Phone No ■-'''..---- CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. El Approved per applicable codes. D38-43? Corrections required prior to approval. Inspecpr:, Date: -(1 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: IDate: 4r-r7-5--As - c ArI l T W k A c I :),g Ur e M 1 5' 6o 1 5 a 1 Pr o t: j a Li g - . IA Type o . nspection: . �r� � ^ Address: I4(0( g Date Called: Special Instructions: / Date Wanted: 1 -21- Q '1 l P.m. Requester: Pho ne1A 33 ! _/ (0 (49(5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. P- (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: I Project: n /( Type of Inspection: A64 : / .a L( ,e • I/1"r Date C #ed`t I/1 / s't/ C Spec" Qstructionvf � 8 Date Wanted: a.m. C Requester. _„ — ( / Phone No: '1 n INSPECT! •N NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION I(z- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. COMMENTS: P ) o 7c / 6 ca 70 I Ilispetb• $ REIN PECTION FF t 6300 Southcenter Blvd., QUIR .� uite 1 Date: 3 rior to inspection, fee ust be 0. Call to schedule reinspection. Rec . t No.: 'Date: 2 . — YG�c`r Corrections required prior to approval. Ame Project: 4 a2/ -,. iglz P - Ts IA/r/C. Type of Inspection: tebog ----- /2? 4fi /iv 6 Address: Date Called: Special Instructions: Date Want / _ .m Requester: Phone No: n2 '5 3 - 0 62 -I/80Y INSPECTION RECORD /3 INSPEC Retain a copy with permit vop T ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 114 r ,414jedi ocr S-eI 0 ,.5 , 6 7 -5 ❑ $60.00 REINSPECTION F REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: I COMMENTS: + J am'" t '- `..- D ,,, s7_, €A ) pi `1 0- < k: ! _ 1,i(-. (--1" (--1" t?-6J AS L Al Date Wanted: i a.m. 3 - - z7 -cam DP r,-4Ak 1 -- ) A1( `'/a( pf 4>J - -- n\ Vt. M1 S ct e tAis a trF -.. 1 e _i t i e ' G e I �, �� ��- -- ( Pd. I t it- ,,.,,rr e .A r(e. 'T - b Ad 3 vi . 2) 'at-TA, 1 SG, ts wr je i ' ,1,„ `mac + 1 3) fart /3( ik p 1ia6 ) 1 0 1 i a/ . •1 ,`0Ar . k *1 ( J eir + K De-A f 7A Project: Type of Inspection: Address: I IC 1 1 P Date Called: Special Instructions: Date Wanted: i a.m. 3 - - z7 -cam Requester: Phone No - 4- 432 - 1- �3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 , Approved per applicable codes. Inspector, DOS-439 Corrections required prior to approval. - I Date:3 -2? ~ �� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: Project i .e2J - �3A ZsMei Tye of Ins ction: / .' /� - e ' cr —/ Address: /we Tl Date Called: Special Instructions: Date Wanted: — Li t'c p.m. Requester: Phone No: .253-282- Wag c4l INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 . 0 A Approved per applicable codes. C6rrections required prior to approval. COMMENTS: N El $60.00 REINSPECTION FEE REQ 14 RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., S ite 100. Call to schedule reinspection. Receipt No.: Date: Project: Type of Inspection Adffress: 1 d 4 1 » 7 P Date Called: 7 Special Instructions: Date Wanted: 9 — 1 ` ate . . - 9 p.m Requester: PhortiAD _ Il0 `o tDoir 437 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ( 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COMMENTS: 311 .9 — plist, 17) 1( \) c I-r, Inspector: Approved per applicable codes. Corrections required prior to approval. Date: h ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: P��t. IA - n�. -� k. + Type of PXY0— �+ ic ( Address: 11 TI-L. Date Called gjo Special Instructions: ) Date Wante J CI JJ C �^ rF P Req a ter: i iti N1 33 , ...... tete g Y�' Su Approved per applicable codes. Dog INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: — V fo444IkoI PFDPl(n .1y). — ;v \ — 6 -b fe—teArc bzvvl . Inspector: 95 (Date: (R to ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ss COMMENTS: Type of Inspection: Firc,L Address: /4401 - Suite #: Contact Person: Special Instructions: Phone No.: Monitor: V.cYt I Pkg.-v., Ck,..--\ .c.< Pre-Fire: a- t1) . 1 . `C` 0 ■(__ Occupancy Type: 164,- Z._ ...... C. kv, 47..., &SA., -;\.. - - -- • - . - - - — . . " - • 1 .. l it . -1EIVN;c^ ..- t ( 0 b .. . . . . . L(NC-kCA SA '.., ....- . \- • Project: A ev - R - -is\cnviy„Gi-te- Type of Inspection: Firc,L Address: /4401 - Suite #: Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: y e 3 1-46„,,, Sprinklers: tees Fire Alarm: w\o,„,, ..k._ Hood & Duct: Monitor: V.cYt I Pkg.-v., Ck,..--\ .c.< Pre-Fire: Permits: N4 0 , a, , Occupancy Type: 164,- Z._ INSPECTION RECORD ' Redin a dopy with permit PERMIT NUMBERS INSPECTION N BER CITY OF TUKVVILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 ,g[Approved per applicable codes. \.r n Corrections required prior to approval. TY\ 5\ Date: ioke\k() eHrs.: t $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F,P. 113 • Project: ' A.A�c,-' 13 i R _1: Awl i s Type of Inspection: S e( u .9. Address: / D I Suite #: - Contact Person: Special Instructions: Permits: Phone No.: Needs Shift Inspection: ' Sprinklers: Firplarm: Hood & Duct: - Monitor: Pre -Fire: Permits: .Occupanc' Type: INSPECTION NUMBER • •Y INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 A pproved per applicable codes. n Corrections required prior to approval. COMMENTS: -w, Inspector: f ,- t s " I Date: 2- /d 7 Hrs.: l n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 COMMENTS: , Type of Inspection: - 5 P / C64- r , Address: i carp .— Suite #: j Contact Person: Special Instructions: Permits: Phope No.: if 4/f itlaono LA2,t 5 oaf. le i " p - -_L fi efs a - c __ 9 ,eo)�L ke... 54v4 G.-p .. - �� ` gyp( y: g` _ _ WQjej nay i di 4 f"' SIe o Fbgts i x ?TV , �^'� A 1 I e ! ! /4 -R,P1 ( y w ` ]?Ti /_e / 1o5;aC 'T Y: ! 3. Pir U , do . 4 ice., i di Atiti ;4v - i _Irat 1 J - /N4 C+ r . . ti _iyt,i- .,t 4 k i , Fr ?- t,,,i- i m Kin Per rep i. a b- Amu , ` - • Project: `41. - _- to 1. g, . -I IArii + c a , Type of Inspection: - 5 P / C64- r , Address: i carp .— Suite #: j Contact Person: Special Instructions: Permits: Phope No.: Needs Shift Inspection: Sprinklers: Are Alarm: _ - Hood & • Duct: Monitor: Pre -Fire: Permits: Occupancy Type: yr �' _•.:a ;? ��:�X_JL:d -xewa - �.�cCie�. h7:Gi:.bsgAmla'f ti. < -:-h l�f✓:'!: '= }'+3p� 'RwK 4w^!tr.;" "yc.it:xi.'.l .aT 5:ti4 Mf „.. u cfek 3 INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Doge q,5 R Y PERMIT NUMBERS 206- 575 -4407 tR Corrections required prior to approval. Inspector: Date: � I e; d Hrs.: k j14'1 I $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Wont /Inspection Record Form.Doc 1/13/06 T:F.AD`. Form F.P. 113 INITIAL TEST DCVA / RPBA CHECK VALVE LEAKED CLOSED TIGHT 2.0 #1 ❑ DCVA / RPBA CHECK VALVE LEAKED CLOSED TIGHT 2.0 #2 ❑ RPBA RELIEF VALVE OPENED: PSID PVBA / SVBA AIR INLET OPENED: PSID PASSED X FAILED TO OPEN: AIR GAR OK? FAILED ❑ X PSID X FAILED TO OPEN: ❑ pry) ❑ NEW PARTS AND REPAIRS CLEAN I REPLACE PART CLEAN / REPLACE ❑ ❑ PART CLEAN / REPLACE ❑ ❑ PART PVBA /SVBA CHECK HELD AT PSID ❑ ' ` ❑ ❑ ❑ O ❑ D LEAKED ❑ 0 ❑ ❑ ❑ ❑ CLEANED ❑ REPAIRED ❑ ❑ ❑ ❑ ❑ ❑ ❑ TEST AFTER REPAIRS REPAIRS PASSED ❑ FAILED [ LEAKED CLOSED TIGHT LEAKED CLOSED TIGHT ❑ ❑ P9D OPENED AT: PSID AIR INLET: PSID ❑ PSID CHK VALVE PSID Pd� 4/b° BACKFLOW PREVENTION ASSEMBLY TEST REPORT CERTIFIED BACKFLOW ASSEMBLY TESTING WA. ST. CONT. LIC. # CERTBRT951BR 253 - 565 -2728 OFC 888 -718 -0500 TOLL FREE SPEC. PLMB. LAC. # FREDEPE980P 1 ACCT / FILE# METER # PERMIT#: PREMISE ABU -BAKR ISLAMIC CENTER COMMERCIAL ® RESIDENTIAL 0 SERVICE ADDDRESS: 14101 INTERNATIONAL BLVD CITY: TUKWILA ZIP 98168 CONTACT PERSON: PHONE: FAX: ASSY. LOCATION: GREEN IRR. BOX BEHIND BUILDING HAZARD TYPE: PREMISE ISOLATION DCVA © RPBA ❑ PVBA ❑ SVBA DCDA ❑ NEW INSTALL: ® EXISTING: ❑ REPLACED: ❑ OLD SN#: PROPER INSTALL: YES © NO ❑ MAKE ASSY: WATTS MODEL: 007M2QT SER. NO: A08833 SIZE: 1.25 AIRP INP EC IION SUPPLY PIPE DIAMETER " SEPARATION: TUKWI l'UbLIC; WO WATER FOUND: 0 I certify DETECTOR METER READING: PASS LINE PRESSURE 80 248 - 290 -4W approved methods and test equipment. NO.: B3415 DATE 18 AUG 09 FAIL U TESTER SIGNATURE PRINTED NAME: PAUL E. FREDERICK TEL. NO.: ( 253) 565-2728 REPAIRED BY: PAUL E. FREDERICK CERT. NO.: FREDEPE980P1 DATE: B3415 DATE: FINAL TEST BY: CERT. NO.: METER CAL DATE 28 JULY 09 MAKE /MODEL: BARTON 247 METER SERIAL NO: 216398 INITIAL TEST DCVA/ RPBA CHECK VALVE LEAKED CLOSED TIGHT 1.9 #1 ❑ DCVA/ RPBA CHECK VALVE LEAKED CLOSED TIGHT 1.8 #2 ❑ RPBA RELIEF VALVE OPENED: PSID PVBA / SVBA AIR INLET OPENED: PSID PASSED X FAILED TO OPEN: AIR GAP: OK? ❑ ❑ X X FAILED TO OPEN: ❑ FAILED pSID psi) NEW PARTS AND REPAIRS CLEAN / REPLACE PART CLEAN / REPLACE ❑ ❑ PART CLEAN / REPLACE ❑ ❑ PART PVBA /SVBA CHECK HELD AT: PSID ❑ I 1 ❑ ❑ ❑ ❑ ❑ ❑ LEAKED ❑ D O D O D O CLEANED ❑ ❑ ❑ ❑ ❑ ❑ ❑ REPAIRED TEST AFTER REPAIRS PASSED ❑ LEAKED CLOSED TIGHT [] ❑ PSID LEAKED CLOSED TIGHT OPENED AT: PSID AIR INLET: PSID ❑ P9D CHK VALVE PSID FAILED BACKFLOW PREVENTION ASSEMBLY TEST REPORT CERTIFIED BACKFLOW ASSEMBLY TESTING WA. ST. CONT. LIC. # CERTBAT951BR 253 - 565 -2728 OFC 888 -718 -0500 TOLL FREE SPEC. PLMB. LIC. # FREDEPE980PI ACCT / FILE# METER # PERMIT #. PREMISE ABU -BAKR ISLAMIC CENTER COMMERCIAL ® RESIDENTIAL fl SERVICE ADDDRESS: 14101 INTERNATIONAL BLVD CITY: TUKWILA ZIP 98168 CONTACT PERSON: ASSY LOCATION: GREEN IRR. BOX BEHIND BUILDING HAZARD TYPE: PREMISE ISOLATION DCVA © RPBA PVBA ❑ SVBA ❑ DCDA ❑ NEW INSTALL: ® EXISTING: ❑ REPLACED: ❑ OLD SN#: PROPER INSTALL: YES © NO ❑ MAKE ASSY: WATTS MODEL: OO7M2QT SER. NO: Al 9983 SIZE: 1.5 AIR GAP INSPECTION: SUPPLY PLPE DIAMETER " SEPARATION: WATER FOUND: ON I certify TESTER SIGNATURE METER CAL DATE PHONE: FAX: DETECTOR METER READING: LINE PRESSURE 80 AC 248-290 -490 approved methods and test equipment. PASS ❑ FAIL CERT. NO.: 83415 DATE 18 AUG 09 PRINTED NAME PAUL E. FREDERICK TEL. NO.: ( 253) 565 -2728 REPAIRED BY: PAUL E. FREDERICK CERT. NO.: FREDEPE98OP1 DATE: FINAL TEST BY: CERT. NO.: B3415 DATE 28 JULY 09 MAKE /MODEL: BARTON 247 METER SERIAL NO: 216398 Closet & Urinal Repairs, Elkay, Halsey Taylor, Haws, drinking fountains, Flushometer Our MailingLst tolreceive�discount j8` special offers Quick Search: All Manufacturers NEVI WED FOR CODE COMPLIANCE APPROVED MAY 2 0 2000 Cityaf Tukwila BUILDIItG DIVISION j -act Iubrr� p.+ec : ae YOUR ONLINE PLUMBING REPAIR PARTS SPECIALISTS" Online Catalog Catalog Home > Drinking Fountains > Elkay Elkay • Drinking Fountains $526.50 Qty: 1 Home I Catalog I About I Request I Order I Contact I Links I Site Map Copyright © 2009, All Rights Reserved. FILE COPY Permit Nn. CORRECTION Page 1 of 1 EHFSA8LIZ Water cooler, wall mount adult ADA legacy model, no lead design, barrier -free ADA design, one piece backsplash and basin, light touch controls, flexi -guard anti - microbial safety bubbler. Comes with light gray granite vinyl clad cabinet, and impact resistant vinyl coating Extra Shipping Charges Apply RECEIVED CITY OF TUKWLA APR 2 2 2009 PERMIT CENTER tv1SION NU. 2 v °S1 http:// www. pacplumbing .com /catalog.html ?iID= 5172 &dID = 715 &pdID = 715 &DeptName =... 4/22/2009 ICC /ANSI A117.1 -2003 601 General Chapter 6. Plumbing Elements and Facilities Chapter Plumbing Elements and Facilities 601.1 Scope. Plumbing elements and facilities re- quired to be accessible by scoping provisions adopted by the administrative authority shall comply with the applicable provisions of Chapter 6. 602 Drinking Fountains 602.1 General. Accessible drinking fountains shall comply with Sections 602 and 307. 602.2 Clear Floor Space. A clear floor space com- plying with Section 305, positioned for a forward ap- proach to the drinking fountain, shall be provided. Knee and toe space complying with Section 306 shall be provided. The clear floor space shall be centered on the drinking fountain. EXCEPTIONS: 1. Drinking fountains for standing persons. 2. Drinking fountains primarily for children's use shall be permitted where the spout is 30 inches (760 mm) maximum above the floor, and a parallel approach complying with Sec- tion 305, centered on the drinking fountain, is provided. 3. In existing buildings, existing drinking foun- tains providing a parallel approach comply- ing with Section 305, centered on the drink- ing fountain, shall be permitted. 4. Where specifically permitted by the adminis- trative authority, a parallel approach comply- ing with Section 305, centered on the drink- ing fountain, shall be permitted for drinking fountains that replace existing drinking foun- tains with a parallel approach. 602.3 Operable Parts. Operable parts shall comply with Section 309. 602.4 Spout Outlet Height. Spout outlets of wheel- chair accessible drinking fountains shall be 36 inch- es (915 mm) maximum above the floor. Spout out- lets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1090 mm) maximum above the floor. 602.5 Spout Location. The spout shall be located 15 inches (380 mm) minimum from the vertical sup- port and 5 inches (125 mm) maximum from the front 5 max 125 380 L 1 (a) Forward Approach 3 max 89 (b) Parallel Approach 15 min Fig. 602.5 Drinking Fountain Spout Location edge of the drinking fountain, including bumpers. Where only a parallel approach is provided, the spout shall be located 3 inches (89 mm) maxi- mum from the front edge of the drinking fountain, in- cluding bumpers. 602.6 Water Flow. The spout shall provide a flow of water 4 inches (102 mm) minimum in height. The angle of the water stream from spouts within 3 inch- es (76 mm) of the front of the drinking fountain shall be 30 degrees maximum, and from spouts between 3 inches (76 mm) and 5 inches (125 mm) from the front of the drinking fountain shall be 15 degrees maximum, measured .horizontally relative to the front face of the drinking fountain. 45 Project Info Project Addres Date s 24 , o b `- Ate- 14101 'TO-441 LA It' TG F.N# i oNIA L 61_4 P , For Building Department Use ,� .„" —,-,, «, - ruK-V1 lLA t WA ©16I Cg, Applicant Name: N12, yo G r■1 VIM � rt_'r Applicant Address: 5fl ^ { &T �g j 3� h}} ' 0z) 3z Applicant Phone: Gj 55 , c l ,g� - Project Description • New Building • Addition K Alteration • Plans ;nc.uded ----- Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive Y'( Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) • No changes are being made to the lighting jg Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft Allowed x Area NOCAuC PL' '{ R-- - A PrAct1 -I) 15 0 0z) 3z 11 -, r�v�o� rt CODE COMPLIANCE ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1 4 1 3 , 2_0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed NOCAuC , fWo R T 15 0 0z) 3z 11 -, r�v�o� rt CODE COMPLIANCE Drc 17 90e: CiLy Of Tukw a BUILDING DW STOry Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts c f 00 I 'CITY OF TUKWILA - BUILDING DIVISION 2Q06 Wasington State Nonresidential Energy Code Compliance Form interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Revised Jul 2007 Proposed Lighting Wattage Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED OCT 2 9 2008 PERMIT CENTER CORRECTION b0B-93`i Use LPA (W /st) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall'" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: Warehouses, storage areas or aircraft storage hangers Other O 0 Q ualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans.' If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) "" • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw - in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG-INT State 2006 Washington Revised July 2007 Nonresidential Energy Code Compliance Forms -1 Ufll (AWer Allowance 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. r t 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor alga not covered by rack$ plus the vertical face area (access side only) of the racks. The height �rtt� wan efiQed�in footnyt�2 a llies ,orflyo the floor area not covered by racial. 4 Location (floor /room no.) Occupancy Description Allowed Watts per ft ** Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft Fl 0 1 Fr 4,5o. zo 2, ii 5. 141.TI I,2 SIIIPY Ci A-ss R-o - Ms I .Z- 1,527.6. 6 • I,0 131 -z.60 5T a. -K 2 6-.0 0 v-rireAll I, 3 3 38 , o u _-( It D 6 15.o0 1 1,1 3z -8.80 PP t, - 1.1- z,4 Z.Z0 0-- U • v 1, 0 4 -16.80 41 s o. F /M. iniASrl 0.S 3 81. Z° 00 qe. 1 .Z V z zo6 . ob CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form LTG -LPA , Power Allowance Adjustments 2006 Washington State Nonresidential Energy Code Compliance Forms Adjusted Lighting Power Allowances (Interior - base on exceptions listed in footnotes Revised July 2007 Project Address kIo► TtAKA1LA ►N1 R -t4Wflc AL F LQ(). Date (0.21, Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Featuring Baldwin er C.Ou�?drl lscoun re a, l k � 4 Free Shipping! t On all orders over $299 L use coupon code' FAt.5HIP Home Categories Home> Brands> Baldwin> Levers > Dummy Set Search Results r #s %(!$ Filter Results Finish 564$ 9147 +4) %.8.% 5# +e°4 %) : — %, &% 5 0 + 8 ' 4 % o !- +5vr460u4$%9) #B4 %/4.% o ! - +)4 16#+18 4 %:l <4 46.C% See More Options Series 01:6 4- E:94+FG:64 %H•% D1:6 4 -E' : --1 •946.% 01:6 4 -E°.8= I #/:=948.% D1:6 4- E11#+41 Q):) 2 %,8% 01 :6 4- E'Q'- 4/' %,H% See More Options Price $J to CORRECTION °t0$- 439 HANDLES ETS Your Online Door Hardware Store s ire 5 %e `° -M t { Schlage &.Ives orders over $99. ' - In•the world on Emtekl E tvi T:E'K use coupon code SAVESCHLAGE use coupon = 1 r — • — • Brands Shop By Room Help 1 2°644% Showing:h hh lbeh Rhsie al tR nh Sort By: w� x $ Click tabs to ch;: nge viev �i . I 7 /1P j Baldwin 5455.FD ecCdhh Soh k : Motidtalli hMrMi 01 Price From: $45.00 Baldwin 5440.FD e cCdh h $$RSoh k : Md?tZhI5 RhMrMi26 Price From: $42.08 Baldwin 5452.FD e cCdh h $ Soh k : Md)dh06 hMrMi26 Price From: $60.00 Baldwin 5485.FD e cCdh h $ Soh k : MmQhlti hMrMi2e Price From: $57.60 Baldwin 5447.FD e cCdh h $$ Soh k : Mdland67hMrMi26 Price From: $34.80 MY ACCOUNT I CUSTOMER SUPPORT I PARTNERS I HELP I Add Search VIEW CART (0 items) CHECK OUT Call Toll Free: (888) 649 -0865 CODE COMPLIANCE APPROVE • PCu61 h O : bCi h : C • SaritMs hoaOOphPCt • PCuOi hOO: bCith edeMd • SarltMe hoaOOphPCt • PCual h00: bCith.aitMl • SarltMe hoaOOphPCt • PCuSA 1190 bCithP6e • SarltMe hoe °OphPCt • PCuerl 1O0: bCietwCt2tbC • SarltMe hoaOOphPCt f Tukwila G r , a IV O F j ,r Page Page 1 of 2 s:bC h8 Baldwin 5460.FD e cCdh h $SRSoh k : Md)dlrtil hMrMi Ui Price From: $42.08 • PCuBI h9O: bCith ertCO eu:up • SarltMe h®OOphPCt argYeiail RECEIVED OCT 292000 PERMIT CENTEF http : / /www.handlesets.com/index.cfin ?page= search: browse &categorylD =57 &manufacturer... 8/6/2008 Fixture Type Model No. Description Battery not connected EZ -21 Two - headed emergency unit (✓) Options (add suffix to model number) -A2 I AC line cord - 120VAC operation (r/) Accessory Items (order separately) Transfer circuit fault WGEL Wire guard VRS Vandal - resistant shield Red Status LED Code Description One brink ON/pause Battery not connected Two brinks ON/pause Battery fault Three blinks ON/pause Charger fault Four brinks ON/pause Transfer circuit fault Five blinks ON/pause _ Lamp head fault Initiating Action Test Cycle Press test switch once 1 minute Press test switch twice 5 minute Press test sw it h 3 times 30 minute Press test switch 4 times 60 mfrute DUAL LITE Dimensions CORR eurioN LTR # Self - Testing /Self - Diagnostic Electronics System �o f 14" MEM 111MU '` ANHUI Unit Features O Fully automatic, 90- minute operation O Compact, low- profile design 0 Easy installation O Injection - molded, flame- rated, thermoplastic housing O Universal mounting plate ▪ Low power consumption © Universal 120/277VAC operation O Maintenance -free battery O Fully automatic, solid -state electronics El Fully adjustable, glare -free lighting heads lid Temperature range: 20 °C to 30 °C (68 °F to 86 °F) ® UL924 Listed (Emergency Lighting) Spectron Features O Meets UL standards for self - testing/self- diagnostic models ® Provides automatic self- diagnostic monitoring and testing of unit operation El Automatically performs routine maintenance and assures operational readiness at all times O Monitors battery, charger, transfer and lamp operation ® Routine discharge cycles insure optimum battery performance and maximum useful life O Automatic 1- minute self -test every 28 days and 30- minute self -test every 6 months O Automatic battery protection O Automatic unit transfer in brownout conditions El Automatic AC lockout circuit "0 Temperature compensated charger O 15- minute retransfer delay O Flashing LED indication of unit malfunction or test cycle Ei All detected malfunctions retained in memory until corrected and retested ® Test switch allows a programmable 1, 5, 30 or 60- minute system check at any time (35.5 cm) Product Selector Decorative and efficient emergency lighting unit designed for fast, easy installation. FILE C RECEIVED OCT 2 9 2008 PERMIT CENTER 2TM Series I Patented: U.S. Patent No. 4,799,039. Foreign Patents Pending. r*S1 ODE COMPLIANCE APPROVED DEC 1 '7 200a City Of Tukwila B TIDING DIVISION Spectron Electronics The Spectron self - testing/self- diagnostic electronics provide: ® Visual indication of AC power status El Visual Indication of all self- diagnostic test cycles 61 Visual indication of unit malfunctions including: • Battery fault • Charger fault • Transfer fault • Lamp fault LED Indicators Red Status LED Under normal operating conditions, the red Status LED indicator will remain off. In the event the Spectron Controller detects a malfunction, the red Status LED will indicate the fault per the table at right. Manual Tests Using the unit test switch, users can initiate 1, 5, 30 or 60- minute diagnostic/discharge cycles per the table at right. Green Status LED The green Status LED serves as both an AC power and a self -test indicator. During normal operation, the green status LED will be constantly illuminated, indicating the presence of AC power. During all automatic or manual self -test cycles, the green Status LED will blink at a 1 cycle per second rate. Hubbell Lighting, Inc. Specifications • Construction Unit and Lamp Housings: Unit housing, back plate, lamp housings and swivels constructed of flame- rated, UV stable thermoplastic Finish: Textured off-white finish Illumination Lamp Type: Incandescent sealed beam type Lamp Voltage: 6 volts Lamp Wattage: 72 watts Rated Lamp Life: 100 hours Photometrics 6 volt, 7.2 watt SBT lamp (Horizontal Isofootcandle Distribution) Photometrics measured by independent testing laboratory Installation Unit Wall Mounting: Unit mounts to 3 ", 4" octagon, or 4" square outlet boxes and standard plaster rings. Back plate provides a universal knockout pattern for mounting to outlet box. Keyholes provided for securing unit housing to wall surface. Knockout provided on top of housing for surface wiring connection. Wiring: Pre - stripped AC input leads provided. All AC connections made inside unit housing. Operating Temperature Range EZ - 21 model: 20 °C to 30 °C (68 °F to 86 °F) Electronics Input: 120/277VAC, 60 Hz. (standard) Charger: Constant voltage, current limited, temperature compensated type Transfer: Solid -state design Built - in Protection: AC lockout, transformer isolation, low battery voltage disconnect, brownout protection and 15- minute retransfer delay Battery Recharge Cycle: Per UL time standards Test Means: Integral test switch Self- Diagnostic Operation LED Indicators: Red "Service Alert" LED indicator and Green "Operating Status" LED indicator Visual Fault Indications: Battery fault, charger fault, transfer fault and lamp fault Service Alert Memory: All detected malfunctions remain in memory until corrected and retested Self- Testing Operation Automatic Test Cycles: 1- minute self -test every 28 days( t 3.5 hours) and a 30 minute self -test every 6 months (± 1 day) Manual Tests: Test switch allows a programmable 1, 5, 30 or 60 minute system check at any time Battery Type: Maintenance -free, Lead -Acid Power Consumption 120VAC: 6.7 watts 277VAC: 72 watts Compliances UL 924 NFPA -101 Dual -Lite a www .dual.lite.com A Hubbell Lighting Inc. brand with representatives' offices in principal cities throughout North America. Copyright° Dual -Lite, All Rights Reserved - Specifications subject to change without notice. Printed in U.S.A. Warranty Unit and Electronics: 5 years full Battery: 10 years (5 years full, 5 years pro-rata) EZ-2TM Series I Decorative Emergency Lighting Unit Suggested Specifications Self-contained emergency lighting unit shall be Dual -Lite Model EZ-2I constructed entirely of flame -rated thermoplastic in textured off-white finish and designed for easy installation. A universal mounting plate shall allow fast, easy wall installation to standard electrical boxes. A universal transformer shall allow operation for 120 or 277VAC, 60 Hz source. Lamp housings shall be fully directional. Emergency illumination shall be provided by two 6 volt, 7.2 watt sealed beam type lamps of glare -free design. Emergency power source shall be a fully rechargeable, maintenance -free, lead-acid battery. SPECTRON electronics operation shall be fully automatic. Accidental discharge of the unit battery prior to energization will be prevented by an AC lockout circuit. The unit's green Status LED located on the Spectron display panel will illuminate to indicate the presence of AC power. The unit's red Status LED will blink after application of AC power if the battery connection is not completed. During normal operation, the unit's charging circuit will maintain the battery at full capacity and the Spectron Controller shall constantly monitor charger performance. Should the terminal voltage vary from design parameter values, the unit's red Status LED will blink, indicating a malfunction of the battery or charger. Upon interruption of normal AC power, or brownout conditions exceeding a 20% drop from nominal voltage, the Spectron Controller shall automatically switch the emergency lighting load to the battery. Emergency power will be provided for a minimum of 90 minutes. During emergency operation, the battery shall be protected from deep discharge by a low- voltage battery disconnect circuit. Upon return of normal utility power the unit will remain in emergency mode for a period of 15 minutes and the charger shall then begin a recharge cycle. The charger will bring the battery to full capacity within acceptable UL time standards. The Spectron Controller will automatically initiate a one minute discharge/diagnostic test every 28 days *3.5 hours and a 30- minute discharge/diagnostic test every 6 months ± 1 day. These tests will be designed to exercise the unit's battery and allow the SPECTRON Controller to analyze emergency operation performance. Any malfunction of the unit's transfer circuit or emergency lamps will cause the red Status LED on the unit's display panel to blink. Under normal operation, all red Status LED blinking indications of unit malfunction shall remain latched until corrected and retested. A manual test switch will allow a user - programmable 1, 5, 30 or 60- minute diagnostic/discharge test at any time. During all automatic and user initiated self- tests, the unit's green Status LED will blink to indicate a diagnostic cycle in process. User self -tests can be canceled at any time by pressing the test switch. 0601102 11/05 LIGHT OUTPUT EQUIVALENCY To dotermini, .whirsh ENERGY STAR quelifiod iif{Mt.butb Zv i peovide the sianvl nrriOu of tight cs your wren, int:ondeseent ti h1 bulbr,ectnsuit the :4 wirl{i c1 rc 40 75 100 150 450 1,100 - "x *(1 2,600 iatZget 9 -13 :13 -15 18 -25 23 -30 30-52 Page 1 of 1 http: / /www.energystar.gov /ia/ products / lighting /cfls/LightOutput_Equival_Chart jpg 9/29/2008 Haws Equipment Page 1 -A Haws 1105 Wall Mounted Drinking Fountains Y E n a^r O P( Permit moo, Model 1105 is a wall mounted stainless steel drinking fountain with 18 gauge type 304, no. 4 satin finish that includes push button valve, polished chrome plated brass bubbler head and waste strainer, vandal resistant bottom plate and 1 -1/4" NPT trap. It offers durability and maintenance, ideal for many locations. It features a one piece stamping with a rounded bowl. Haws manufatures drinking fountains, electric water coolers and electric drinking fountains to be lead free by all known definitions including ANSI/NSF Standard 61, Section 9, California Proposition 65 and the Federal Safe Drinking Water Act. Components: Bubbler Head: Model 5703M, polished chrome plated forged brass, integral basin shank, shielded, anti - squirt, vandal resistant bubbler head. In -Line Strainer: Model 6420, bowl type strainer with positive rubber seals molded onto a fine 60 micron mesh screeen. Valve: Model 5872, push button activation, front adjustable, automatic diaphragm pressure regulation with fully adjustable flow. Waste Strainer: Model 6462, polished chrome plated brass, vandal resistant combination waste strainer and tailpiece assembly. Push Button: Model PBA2, push button assembly has a polished chrome plated finish. Bottom Plate: Model PBM1105, bottom plate with vandal resistant screws. Trap: Model 0005982900, low profile trap. Options & Accessories (Additional Cost) Wall Mounted Drinking Fountain: Model 1105BP, single bubbler, wall mounted with back panel, stainless steel drinking fountain with no. 4 satin finish. Wall Mounted Drinking Fountain: Model 1109, single bubbler, wall mounted, barrier free, stainless steel drinking fountain with no. 4 satin finish. Wall Mounted Drinking Fountain: Model 1119, dual height, wall mounted stainless steel drinking fountain with no. 4 satin finish. Barrier Free Electric Drinking Fountain: Model HI 109.8, barrier free, wall mounted stainless steel electric water cooler with no. 4 satin finish. Filter: Model 6426, 12" x 2" in -line lead removal element that reduces lead from incoming water to levels below 15 ppb for up to 500 gallons. Mounting: Model 6700, mounting plate with all thread studs, nuts and washers. Support Carrier: Model 6800, in -the -wall struts for fountains that may be subjected to excessive leverage. Must be used with mounting plate (not included with carrier). Chiller: Model HCR8, chiller provides for instantaneous cooling to meet a continuous demand for chilled water. cm CORRECTION LTR #_ —L_e X08 4 39 • IC.cV COVIP tiC 11" ROVIE COD DEc 1 ' 2008 hltn: / /www western cafPty nom / hawcnPu rfn»ntainc/ha.x,cpn „i„mPnt., l, t..,i Page 1 of 2 RECEIVED OCT 29 PERMIT CENTE t n Haws Equipment Page 1 -A Page 2 of 2 -i/4 in TRAP (suPPt:o) SUPPLY STOP AND_: 3/Fr AD SUPPLY (BY OTHERS) MOOR UN WALL FACE tJ2 I S APPLY {8r OP -VtS) BAG PANEL (OPTCNAL) (MODEL 1105BP) hltn' / /www.westerneafety cnm/hawcnewfrnlntai c/hawcerm rim entr.a1 _a html 1 n /7n /')nnQ NW ARCHITECTURE 3828 4 AVE S., STE. 7 SEATTLE, WA 98134 T: (206) 355 -9686 / F: (206) 624 -5604 Date: 4/22/09 To: Mr. Dave Larson, Bldg. Dept. cc: Owner, Contractor From: Young Kim Project No. /Name: ABU - BAKR ISLAMIC CENTER (D08 - 439) 14101 Tukwila International Blvd., Tukwila, WA 98168 Total # of pages: # (including cover) Subject: 4/8/09 Review Comments Dear Mr. Larson, thanks for your review comments and please refer below responses. 1. Drawings: A2.2, A2.2A, A2.4, A4.1: Response: Yes, Please refer the submitted. 2. Drinking Fountain: Response: Yes, three fountains are provided. Please refer A2.1 revision 6 cloud. Also, please refer the attached spec. sheet and ANSI A117.1 -2003 copy. 3. 18" vertical grab bar: Response: Pls refer5a/ A1.1. Please feel free to ask further if you have more questions. Thank you. Sincerely, o ng Kim, AIA • • Transmittal April 8, 2009 Young Kim 3828 Fourth Avenue S, #7 Seattle, WA 98134 RE: CORRECTION LETTER #1 to Revision #2 Development Application Number D08 -439 Abu -Bakr Islamic Center —14101 Tukwila International BI Dear Mr. Kim, Department of Community Development Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time, the Fire, Planning and Public Works Departments have no comments. Building Department: Dave Larson at 206 - 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, -- I ,:t 0 .--- Z a/ie S D Bill Rambo Permit Technician encl File No. D08 -439 P:\Permit Center\Correction Letters \2008\D08 -439 Correction Ltr #1 TO Rev #2.DOC wer Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo • Date: April 8, 2009 Project Name: Abu -Bakr Islamic Center Permit #: D08 -439 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. All pages of the approved plans affected by the proposed revisions need to be updated to show the changes. Page A2.2 has been submitted showing revisions that have not been changed on pages A2.2, A2.2A, A2.4, and A4.1. Please revise these pages as well to make the complete set of approved plans accurate. 2. The drinking fountains shown need to serve a person in a wheelchair and a standing person. Please provide details for a combination water fountain or show two water fountains at each location. An elevation view of the proposed water fountain would be helpful to check required measurements. 3. The current codes require an 18 inch vertical grab bar on the side wall of the toilet space. This bar was not shown on the detail originally provided. Please add this bar to the elevation detail and give placement measurements show that it is clear to the installer as to where it is to be located. These measurements can be found on page 48 of ICC /ANSI A117.1 -2003 Accessibility Standards. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. 02 -02 -2009 YOUNG KIM 3828 FOURTH AVE S #7 SEATTLE WA 98134 RE: Permit Application No. D08 -439 14101 TUKWILA INTERNATIONAL BL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 09/19/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 03/18/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 03/18/2009. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Mars all Technician Permit File No. D08 -439 Guy of f 7'idkW1 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 DATE: CONTACT: RE: ADDRESS: ZONING: PLANNING DIVISION COMMENTS December 15, 2008 Young Kim D08 -439, Conditions 14101 TIB NCC The Planning Division of DCD has reviewed the above permit application. The application as submitted is approved subject to the following condition(s): 1. All site improvements including striping and landscaping proposed with this project shall be completed prior to final occupancy being issued by the City. No worship services or other functions are allowed to occur on the property until a certificate of occupancy is issued by the City. 2. No modifications shall be made the approved landscaping plant without prior approval of the City. 3. Prior to occupancy the Mosque shall provide a minimum of 114 parking spaces. The parking area shall comply with the design standards specified in TMC 18.56. Since the required number of parking stalls will be located over two tax parcels the applicant shall establish and have recorded a Shared and Covenant Parking Agreement between the Mosque property and the Pawn X- Change property. The language of the Shared and Covenant Parking Agreement shall be approved by the City and shall be consistent with TMC 18.56.070. The Shared and Covenant Parking Agreement shall be recorded with King County Department of Records prior to final occupancy of the building. The applicant could also choose to combine the two parcels through a lot consolidation process. 4. Prior to the certificate of occupancy being issued for the proposed mosque the applicant shall provide a lighting plan which demonstrates compliance with the lightings standards of Tukwila International Blvd Design Manual. 5. A separate sign permit is required for all outdoor signs on the site. 6. The applicant shall comply with all requirements contained in the Department of Community Development's Notice of Decision regarding Parking issued on September 10, 2008. December 2, 2008 Young Kim 3828 Fourth Avenue S, #7 Seattle, WA 98134 RE: CORRECTION LETTER #2 Development Application Number D08 -439 Abu -Bakr Islamic Center —14101 Tukwila International Bl Dear Mr. Kim: If you have any questions, please contact me at (206) 431 -3670. Sincerely, 7 Bill Rambo Permit Technician encl File No. D08 -439 S P:\Permit Center\Co,rection Letters ‘2008008-439 Correction Ur #2.DOC wer Department of Community Development In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Jim Haggerton, Mayor This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Planning Department. At this time, the Building, Fire and Public Works Departments have no comments. Planning Department: Brandon Miles at 206 -431 -3684 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 DATE: CONTACT: RE: ADDRESS: ZONING: Please note: December 2, 2008 Young Kim D08 -439, Correction Letter #2 14101 TIB NCC PLANNING DIVISION COMMENTS The Planning Division of DCD has reviewed the above permit application. The application as submitted cannot be approved. 1. Eliminate parking stall number 56 on sheet A1.2. The parking stall is too close to the access from TIB. 2. The details provided need to be updated in order for all parties to have a clear understanding of the work being preformed along S. 141 Street. Provide a cross section showing the following, center line of S. 141 Street, proposed fog line, curb line, property line and landscaping area. Public Works does not allow diagonal pavement striping. To delineate the edge of the vehicular travel lane the applicant shall install a solid white thermoplastic four inch wide fog (edge) line per WSDOT standard specifications. Exact fog line location shall be approved in the field by PW project inspector prior to placement. Please add appropriate notes on the plans. 3. As noted, in comment #2 the proposed shaded area along S. 141 Street needs to be replaced with a fog line. The fog line needs to be consistent with City of Tukwila design standards. 4. Wheel stops will need to be added along the compact stalls along the northern landscaping area. This is needed in order to prevent cars from damaging trees and shrubs in the landscaping island. 5. A lighting plan needs to be provided for the parking area. The plan needs to show the illumination standards for both parcels and comply with the conditions specified in the Conditional Use Permit. 6. The existing Fire Department connection (FDC) mounted on the south building wall shall be replaced with Storz Knox Cap(s) manufactured by Knox Corporation. Prior to final occupancy of the building, either shared parking agreement shall be reviewed by the City and recorded with King County or the two parcels that make up the subject site shall be consolidated into one lot. Please remember that this needs to be done so that final occupancy is not delayed. 4 October 13, 2008 Young Kim 3828 Fourth Avenue S, #7 Seattle, WA 98134 Dear Mr. Kim: Sincerely, Brenda Holt Permit Coordinator encl File No. D08 -439 O Department of Community Development RE: CORRECTION LETTER #1 Development Application Number D08 -439 Abu -Bakr Islamic Center —14101 Tukwila International BI This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Planning Departments. At this time, the Fire and Public Works Departments have no comments. Building Department: Dave Larson at 206 - 431 -3678 if you have questions regarding the attached comments. Planning Department: Brandon Miles at 206 - 431 -3684 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. P:\Pennit Center\Correction Letters\2008\DO8 -439 Correction Ltr #1.DOC wer Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 o Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 Building Division Review Memo Date: October 1, 2008 Project Name: ABU -BAKR ISLAMIC CENTER Permit #: D08 -439 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The 3830 sq. ft. Pray / Worship room exceeds 500 occupants and therefore would require three exits. As shown this room only has two viable exits. The 82 sq. ft. main entrance is one. The other is through the 145 sq. ft. hall in the northwest corner of the space. The hallway is considered a separate room and therefore the exit from the Pray / Worship room would be considered the entrance to the hall. This counts as one exit even though there are two exits in the hall. Please provide a third exit from this space that complies with code requirements. 2. Please modify the means of egress plan or fire exit plan on sheet A2.4. We prefer to see the means of egress depicted as a shaded path through the space connecting at least two exits when two or more exits are required. The common paths leading to the means of egress should not be shaded. The maximum distance a person can travel from a most remote point to the means of egress is per section 1014.3 IBC, 1014.4.2 IBC and 1025.8 IBC. Once a person reaches the means of egress pathway, they need to be able to travel in at least two distinct directions to an exit. The means of egress path is required to have emergency lighting along its entire length at intensity levels per section 1006.4 IBC. Please show compliance with this requirement on plans. This plan is also a good place to show placement of lighted exit signage. The width of the means of egress path shall be per section 1005.1 IBC and shall be indicated on the plan. This pathway must be maintained as a clear and unobstructed path to the exits and therefore should not be shown as passing through pray areas unless a clear aisle can be maintained. 3. Accessible drinking fountains are required as well as drinking fountains for people in the standing position. Please show compliance with section 1109.5 IBC. Please note that drinking fountains installed in a hallway must not reduce the minimum required width for exiting purposes. 4. Per section 1109.2 of the IBC, toilet and bathing rooms are to be accessible unless meeting one of the five exceptions noted in the same section. At least one of each type of fixture provided needs to be accessible. The shower in the mens washroom will need to be accessible. A toilet compartment and a lavatory sink and associated dispensers and grab bars should be shown on the plans for the main mens and womens toilet/bathing rooms. • 5. The door schedule will need to include the specific hardware proposed for each door. 6. One emergency light fixture is needed on the exterior side of each exterior exit door. Please show this on the plans. Also, note that the interior emergency lighting needs to be aligned with the egress path discussed in item 2 above. The interior exit lighting shall provide an average of 1 foot — candle, but not less than .1 ft. candle along the main egress paths. 7. Please provide details for location and description of all required barrier free signage. 8. Bathroom exhaust fans are shown as exhausting 50 CFM. See table 403.3 of the international Mechanical Code under public spaces. Required outdoor ventilation air is 75 cfm per water closet or urinal. Please change notes on plans as necessary to comply. 9. Occupant load signage needs to be posted for A occupancies. Show location and description of signs to be posted per section 1004.3 IBC. 10. The lighting budget was not completed and not correctly filled out. Totals for allowed and proposed were not filled in. Under allowed wattage use .8 watts per sq. ft. for halls, toilet facilities and washrooms. Use 1 watt per sq. ft. for office spaces and 1.2 watts per sq. ft. for assembly uses. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. DATE: CONTACT: RE: ADDRESS: ZONING: Please note: 0 October 10, 2008 Young Kim D08 -439 14101 TIB NCC PLANNING DIVISION COMMENTS • The Planning Division of DCD has reviewed the above permit application. The application as submitted cannot be approved. 1. The proposed application proposes to install parking on the south side of the existing Pawn X- Change Building, provide the degree angle for the proposed parking and ensure that the parking complies with TMC 18.56.040. 2. Provide a detail sheet for the site work along the north portion of the property along S. 141 Street. Provide details on type of curbing and striping of the pedestrian path. 3. Update sheet A2.2 to reflect the net pray area. 4. Update sheet A2.2A to reflect the net pray area. 5. Sheet A1.2 and sheet L -1 conflict with each other. For example sheet A1.2 shows parallel parking along the front setback, yet this is not shown on the landscaping plan. 6. A condition of the CUP approval was to submit a lighting plan which must meet the City's TIBDG lighting standards, please provide the lighting plan as part of the building permit submittal. 1. The City reviewed an earlier copy of sheet A2.1 as part of the conditional use permit (CUP) process. Sheet A2.1 that was submitted with the building permit is not the same as the verision reviewed with the CUP application. The building permit version does not impact the square footage of the prayer and worship areas, however the City's did attempt to provide comments related to building code issues as part of the CUP process given that the floor plan has changed those initial comments are not longer relevant. 2. Prior to final occupancy of the building, either shared parking agreement shall be reviewed by the City and recorded with King County or the two parcels that make up the subject site shall be consolidated into one lot. Please remember that this needs to be done so that final occupancy is not delayed. 0 Joanna Spencer - Fwd: Abu Bakr Traffic Impact Fees From: Joanna Spencer To: yknwa @yahoo.com Date: 12/29/2008 4:30 PM Subject: Fwd: Abu Bakr Traffic Impact Fees FYI, Cyndy • Page 1 of I »> Cyndy Knighton 12/29/2008 4:25 PM »> The TIA that was dated on April 29, 2008 is the last information received with trip generation information. I commented on it on May 12, 2008 with corrections. In my comments, I determined that the trip generation for this site, for the pm peak hour, is 10 trips. Since no other information has been presented to the city in the contrary, I will use this number to calculate impact fees. The project site is in Zone 3 and is assessed at $1,061.20 per new pm peak hour trip, making the impact fee due for this project $10,612.00. PERMANENT FILE COPY DOS file• //( AO< ;mil 1 n+„ v_r„ n; l42nn _,,.,1nn12114A11PASR1 \(W1 nnnn1 N 17/7o/7nfR Joanna Spencer - Abu Bakr Mosque Page 1 :'. From: Cyndy Knighton To: Brandon Miles; Joanna Spencer Date: 05/12/2008 6:55 pm Subject: Abu Bakr Mosque CC: Minnie Dhaliwal My comments on the most recently submitted report, Trip Generation and Parking Analysis, are as follows. 1. Parking generation: I didn't review this section closely. Parking requirements are under the purview of DCD. However, I am disappointed that they chose to include a mosque in a densely urban area (downtown Seattle) as a comparable mosque. I would have thought that the mosque in my neighborhood in north Seattle (Northgate area) would have been a better choice as it's much more similar in neighborhood makeup to the site here in Tukwila. But that is irrelevant at this point. 2. I am troubled by this report's use of an AVO that differs from the standard definition. The intent of this requested study was to determine the need for parking supply as well as site access impacts. While it is useful to know how many people have taken alternate modes of transportation to attend the Friday prayers, those transit, pedestrian, and other non - passenger /vehicular trips are extraneous. I cannot glean from the data presented the total number of passenger vehicles generated by site without some sense of doubt as to whether they include pedestrians, buses, taxis, and so forth. That really must be clarified before their application comes in. We need to know the number of car trip ends. Identifying the number of transit users and pedestrians is also necessary to support any claims for reduced trip generation, but they absolutely must be separately identified. 3. There is no supporting evidence or data to this report, or the previous report, for the application of a 25% trip generation reduction for pass -by trips. The ITE trip generation manual, which this report is using, also does not have any supporting data for the application of ANY reduction for pass -by trips. Therefore, no reduction will be allowed. 4. Use of the ITE Trip Generation Manual for the PM peak hour trips is acceptable but it must be applied to the entire building size. This report shows that correctly. But as described above, no allowance for pass -by trips will be given. Therefore the PM Peak Hour trip generation is established at 0.66 times 14,360 sf divided by 1,000 or 10 trips (9.47 rounded up to 10 trips). 5. If I have interpreted the number of vehicles correctly, then the worst case scenario for trip generation for the peak of the site would be 40.5 trips per thousand square feet of assembly area. This is the average of all the number of vehicles divided by the assembly area multiplied by 2 for both incoming and outgoing. No solid data was presented to guide me in determining how much of the trip generation would be outside of the peak one hour -- just commentary about some people arriving early or staying late. This then yields a trip generation of 154 trips for the site's peak on Friday prayers. Site access will need to be designed to accommodate this trip generation if it's not already there. Cyndy PERMANENT FILE COPY 0 7-o .**63gobe, Trip Generation & Parking Analysis Abu Bakr Islamic Center /Mosque April 29, 2008 10 °111 : SU Prepared for: we City of Tukwila Department of Community Development No. p Pment RE07 -051 Prepared by Mohammad Jalalyar, PE 1954 Union Ave. NE Renton, WA 98059 Cell: (206) 799 -1379 PERMANENT FILE COPY RECEIVED MAY 0 7 2008 TUKWILA PUBLIC WORKS Work Location: Indemnification and Hold Harmless and Permit Temporary in Nature and Permit Number(s) of Related Document(s): D08 -439 Grantor /Borrower: A L I I ASS A N -I\ fi MED 1`1 S 21_6 11 Ave.. s , , (,l? A q Y U 1 Grantee /Beneficiary: CITY OF TUKWILA, a municipal corporation of King County, Washington 5: 1 4 1 ST. Abbreviated Work Description: -r itd51H F06, L TrjC INtER`SE 01 '1 or T I B 10 THE I•1✓`:)T Fp -UpCk TY CekNE:K ON THE 5GL Tfj 51PE OF Tli 51 NOW, THEREFORE, the parties agree as follows: The Permittee shall indemnify, defend and hold harmless the City, its officers, agents and employees, from and against any and all claims, losses or liability, including attorney's fees, arising from injury or death to persons or damage to property occasioned by any act, omission or failure of the Permittee, its officers, agents and employees, in using the City's right -of -way under this permit. This indemnification and hold harmless shall not apply to any damage resulting from the sole negligence of the City, its agents and employees. To the extent any of the damages referenced by this paragraph were caused by or resulted from the concurrent negligence of the City, its agents or employees, this obligation to indemnify, defend and hold harmless is valid and enforceable only to the extent of the negligence of the Permittee, its officers, agents, and employees. Further, the right -of -way permit herein is wholly of a temporary nature and it vests no permanent right to use whatsoever to the Permittee. Page _ of DATED this GRANTEE: By: Print Name: Its: 31 st STATE OF WASHINGTON COUNTY OF KING day of CITY of TUKWILA carrlaa.u. -Tsicetsust......) James Morrow Public Works Director , 200 On this day, before me personally appeared JIM MORROW to me known to be the PUBLIC WORKS DIRECTOR for the City of Tukwila, and executed this instrument on behalf of the City of Tukwila in his capacity as PUBLIC WORKS DIRECTOR and acknowledged that he is authorized to do so at his free and voluntary act and deed, for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. i:;/` a6(}}ta, Name: � e 4 L Je/ NOTARY PUBLIC, in and for the State of Washington, residing at My commission expires: .2$-9-(() DATED this m ) day of b , 200 iK GRANTOR(s): GRANTOR(s): individual(s) STATE OF WASHINGTON COUNTY OF KING On this .3c day of i t , 2008 , before me a Notary Public in and for thg State of Washington, personally appeared A- , , and , to me known to be the individual(s) that executed the foregoing instrument, and acknowledged it to be the free and voluntary act of said individual(s), for the uses and purposes mentioned in this instrument, and on oath stated that he /she /they was /were authorized to execute said instrument. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. , ij Scuv . gcnr.K 4 40(,1 - Name: ss. NOTARY PUBLIC, in and for the State of Washington, residing at i My commission expires: Page _1 oLI_ )0 I 19 l DEPART ENTS: Lidding Di 'sion Public Works n Complete Comments: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents /routing slip.doc 2 -28 -02 • PERMIT PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -439 DATE: 06 -19 -09 PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 3 After Permit Issued APPROVALS OR CORRECTIONS: Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: Structural Review Required Approved Approved with Conditions Notation: REVIEWER'S INITIALS: AA AM- ti0 -3-09 1.� Fire Prevention Planning Division Permit Coordinator DUE DATE: 06-23-09 Not Applicable No further Review Required DATE: DUE DATE: 07 -21 -09 Not Approved (attach comments) DATE: rV ►2 n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -439 DATE: 04 -22 -09 PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 X Revision # 2 After Permit Issued DEPARTMENTS: P ilding D ion Public Works DETERMINATI Complete Comments: Permit Center Use Only, • ' INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R TING: Please Route Structural Review Required — No further Review Required El REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP Fire Prevention Structural OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ El DATE: ❑ Permit Coordinator Approved ❑ Approved with Conditions _ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Planning Division Not Applicable DUE DATE: 04-23-09 DUE DATE: 0521-09 Permit Center Use Only - CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Building Division Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 0 PERMIT CORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 - 439 DATE: 04 - - PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 2 After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator Not Applicable Approved Approved with Conditions n Not Approved (attach comments) lier Notation: REVIEWER'S INITIALS: DUE DATE: 04-07-09 Pi DUE DATE: 05-05-09 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: I-1-8 Bldg thr Fire ❑ Ping ❑ PW ❑ Staff Initials: u2 ACTIVITY NUMBER: D08 - 439 DATE: 03 - - PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENT /� Bui ing Division O Public Works ❑ Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ u DATE: DATE: Planning Division Permit Coordinator DUE DATE: 03-31-09 Not Applicable Permit Center. Use Only • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW El Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required H No further Review Required DUE DATE: 04 -28-09 Approved Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -439 DATE: 12 -10 -08 PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works DETERMINATION 0 COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -11 -08 Complete Comments: TUES/THURS ROUTING: Please Route Documents /routing slip.doc 2 -28 -02 t Ell r rl , a, Rjt PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: Fire Prevention Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: 1 Pla ning Division n Permit Coordinator Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DATE: DUE DATE: 01 -08 -09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08439 DATE: 10-29-08 PROJECT NAME: ABU4EIAKR !ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: :kW B lik-a) Edcrig Division Public Works 111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: Notation: Documents/routing slip.doc 2-28-02 'P ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP REVIEWER'S INITIALS: Fire Prevention Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved El Approved with Conditions LI Lil DATE: DATE: Planning Division Permit Coordinator Not Applicable No further Review Required • &I 11- DUE DATE: 10-30-08 Comments: Perrilit Ceitedit. Vier:4113K: ' • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 DUE DATE: 11-27-08 L. Fr Not Approved (attach comments) Permit dearere brif4s.' • • • - • • : e • •; P.. 4 . CORRECTION LETT ER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW 0 Staff Initials: DEPART ENTS: Btli? k g s n Public orks Complete Comments: E ice! • .MIT COORD COPY PLAN REVIEW /ROUTING SLIP i rY I ACTIVITY NUMBER: D08 -439 DATE: 09 -19 -08 PROJECT NAME: ABU -BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued Fire Prevention Structural Incomplete DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Plannini Division Permit Coordinator DUE DATE: 09 -23 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R TING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 DATE: DATE: DUE DATE: 10 -21 -08 Approved _ Approved with Conditions n Not Approved (attach comments) I" I Notation: REVIEWER'S INITIALS: Permit Center Use Only /�, ��^� CORRECTION LETTER MAILED: 0 (/ - Ob i Departments issued corrections: Bldg I? Fire ❑ Ping ( PW ❑ Staff Initials: u REVISION NO. DATE RECEIVED STAFF INITIALS STAFF INITIALS ISSUED DATE .3 STAFF INIT ALS 1 o 1 o Summary of Revision: frpOunv kin, 107 e otod, W ae. o u f w \ - 3r' - Received by: 1 4LP SS, ' / Aildeo f Received by: Summary of Revision: w6—yi/ o2 4/ pa, vvvo Vrirap Received by: j-k(sS e l 0 A L i ' REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITL4LS �N( .3 DA . 0 01 : (9 Summary of Revision: frpOunv kin, 107 e otod, W ae. o . nI\AcAX . " A GIWP^Cl., Received by: 1 4LP SS, ' / Aildeo f REVISION NO. DATE RECEIVED STAFF ISSUED DATE STAFF nvlT�(s 1-- .3 Co-1 -Coq Litt 1-,2Lf -D Summary of Revision: r v y A " or („J crw r I o J o ww► �c k 9 livveCtAR4/1; cid Summary of Revision: Received by: Z W. AY--/ &7) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION . NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S ummary of Revision: Received by: PROJECT NAME: SITE ADDRESS: • 05.1A -pKvA,p- iNID■ 'f18 REVISION LOG ORIGINAL ISSUE DATE: 05 PERMIT NO: (please print) (please print) (please print) (please print) ease print) o2-12ob7 Date: ( 0 ° I ' 0 9 Project Name: Sheet Number(s): Az, City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Received at the City of Tukwila Permit Center by: Entered in Permits Plus on l9 19,_0/ Plan Check/Permit Number: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # Response to Correction Letter # rx Revision # 3 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner At31.1 —gAK12 ISLAMI Project Address: 14 (01 -U W i LA I NT ' L -g LV Contact Person: Y U lI G K ly Phone Number: 7.o/) 12, S 6 - q 6 P6 Summary of Revision: OCC (1 A N c`' k' AO 00 A-KCJitrE cFu 1eA L 1J g4 w U J c - r o MATcI w ( Mc)-(\ pL cA1 . pt 11 500 @M. PIT RIA , o @ -l✓M ALE P M-`f 1200)1 OF A I JUN ,1 2009 PERMIT CPt TF "Cloud" or highlight all areas of revision including date o revision 1 6oS - ti39 City of Tukwila Revision submittals must be submitted in person at the Permit Center: Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D08 -439 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 • Revision # 2 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Proj ect Name: ABU -BAKR ISLAMIC CENTER Project Address: 14101 Tukwila International B1 Contact Person: ' IOU t`l(o k tfk_ Phone Number: ZO 6 p, l 6 n -, Summary of Revision: i) (13 cu rn■ ) (A)as' r_rmvvt _ _ is e on re-(o eci s h eel=s 2) Orin n u v\ ; - n a pe r_. aCce -ss_ h -J _, --t- 3) \ rti c d t b bars. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: / 0, W∎c, Entered in Permits Plus on \applications \forms= applications on line\revision submittal Created: 8 -13 =2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206. 431 =3665 Web site• http..//www=ei=taInvila: Steven M. Mullet, Mayor Steve Lancaster, Director OF ro ftvitA APR 22 2009 PERM,rcERrER Date: Created: 8 -13 -2004 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Received at the City of Tukwila Permit Center by: Entered in Permits Plus on k lapplieations\forms- applications on linelrevision submittal Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # k j Revision # ' L, after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director R CITY p tA APR 02 2009 QEVrati Project Name: ANA - 64 / -- 1SLAMIC Ce'Nir U-- Project Address: \ 4- W 0 I — 1 — k-A K.-Lo I LA I N T L $ L l/ P Contact Person: )01.1 i AA Phone Number: 20 4 ) 3 56 - 6 �b Summary of Revision: ACrL Q I of() ii J a,_< k r67)1AA -- ri'xivrP 5.. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: &‘°1 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: CRY p Ch MAR 3 0 Z009 ;A 6 U- B /� IZ 14 L 4�-1 ' I G PERMIT C EA P k L\J D r i t/\ Phone Number: (. 2() Summary of Revision: I NT W X1,5 a Sheet Number(s): ,4 Z _1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ( 1 7 9 19 A lapplications\fornu- applications on linekevision submittal Created: 8 -13 -2004 Dw...A• Steven M. Mullet, Mayor Steve Lancaster, Director Date: i'Z k 1 0 ' r» Summary of Revision: City of Tukwila \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http : //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc 3 Plan Check/Permit Number: DoP) ❑ Response to Incomplete Letter # J' Response to Correction Letter # 2 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: /obi,(- t LA-M Project Address: ( t r i o . t r t i I L( Contact Person: `(0 U, N (o K l h'\ Phone Number: 2_o(, 3 5 5 G 6 a-6 ?GlrKivic Lot 56 3e Ietec( 2.. C.i2o SS 5'r_cri ot.l � l (� �v I �' I st St 4. LiJt eel fps 5 . i ' Ate' 6 Lor L 601 M i'n FLA0 : TAP fekrPfI pert f • 6 - R re Dept : R Sheet Number(s): A- I • Z "Cloud" or highlight all areas of revision includinidate of revision Received at the City of Tukwila Permit Center by: IEr Entered in Permits Plus on (0 Steven M. Mullet, Mayor Steve Lancaster, Director 43R RECEIVED env OFTUKWIlA DEC 10 200a t'li)4MIT CENTER City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10 "[ Plan Check/Permit Number: D08 -439 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ABU -BAKR ISLAMIC CENTER Project Address: 1 4101 Tukwila International B1 Contact Person: Young Kim Phone Number: Summary of Revision: RECEIVED CRY OF TUKWILA OCT 2 9 2008 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including dat of revision ' Received at the City of Tukwila Permit Center by: 1 Entered in Permits Plus on (0- g \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 3 6 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 tO 4, f) Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 8 3 4 5 30 Water closet, tank or valve, >1.6 GPF la Department of oof N atural Resources and Parks Wastewater Treatment Division Non-Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type P ! )O1 A u ( LA IN T" 1- TuK1LA WA. City State Mr . M14 li AMgp TA Owner's Name Subdivision Name Lot # Subdiv. # Block # Building Name A ' BAKP— ISLAMit cr IA/4 Of applicable) ( ?4 ) `1q - 1-3161 Owner's Phone Number (with Area Code) ( `2 - '-j q q - 1 Property Contact Phone Number (with Area Code) Owner's Mailing Address ItIO l -r'li id 1o. L eLVv. Kwl VGA- cal A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Total Fxture Units r ib Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units 20 Signature of Owner /Representative �b u iJ • 3.8 D S i t 3 q For King County Us Only RCE BLVD ZIP Account # No. of RCEs Monthly Rate Property Tax ID # b ( 0 1 © © © 1 Party to be Billed (if different from owner) City or Sewer District ("AD( c - - K(+) I L-R Date of Connection Side Sewer Permit # Please report any demolitions of pre - existing building on this property. Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes ❑ No Was building on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B 3,6 3,8 RCE RCE RECEIVED SEP 'I 9 2008 PERMIT CENTEF. Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for determination of a revised capacity charge. Date 9 t o.0P Print Name of Owner /Representative - ! 1058 (Rev. 9/07' - White - K:nr, Count" Ye:Pow - : ;cap Sewe ace' . Pink - Sewer C;:s'orrer Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 COLONIAL AM CAS SURETY OF M LPM4077329 11/17/2008 Until Cancelled Date Date $12,000.00 11 /18 /2008 Name Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date LLOYDS OF 1 LONDON A1Q91068511/03/200811/03/2009 $1,000,000.0011 /18/2008 (UNDERWRITER Name Role Effective Date Expiration Date Yim, Hee G PRESIDENT 11/18/2008 Yim, Hee G VICE PRESIDENT 11/18/2008 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Seattle Builders Inc 2063758160 9707 18th Ave Ct S #S -3 TACOMA WA 98444 PIERCE Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602872297 ACTIVE SEATTBI922QQ CONSTRUCTION CONTRACTOR 11/18/2008 11/18/2010 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • Page 1 of 1 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= SEATTBI922QQ 03/02/2009 - REQ'D PROV'D ZONING: NCC NCC CONDITIONAL USE PERMIT CONDITIONAL USE PERMIT CONDITIONAL USE PERMIT PARKING (FIG. 18 -7): (PRAY & MULTIL RM) 1/4 SEATS OR 1/100 SF (5,691 SF) 114 PROV'D (107 LOTS + 7 LOTS) BIKE RACK (1/50 PARK'G LOTS): 3 REQ'D 3 PROV'D HEIGHT N/A N/A SETBACK N/A N/A LANDSCAPE YES YES O RD GENERAL NOTES 1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC., AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 2. ALL CONSTRUCTION SHALL COMPLY WITH THE SEATTLE 2006 INTERNATIONAL BUILDING CODE, WASHINGTON STATE REGULATIONS FOR BARRIER FREE DESIGN, WASHINGTON STATE ENERGY CODE ('06 IBC), AND ALL APPLICABLE LOCAL CODES, ORDINANCE, AND STANDARDS. 3. ALL ITEMS MARKED "N.I.C." ARE NOT PART OF THIS CONTRACT. 4. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 5. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. CONTRACTOR SHALL CONSULT OWNER'S REPRESENTATIVE WHEN ADDRESSING QUESTIONS OF MATERIALS, METHODS, DETAILS OR WORKMANSHIP NOT COVERED IN THE CONTRACT DOCUMENTS. 6. ALL DIMENSIONS SHOWN ON DRAWINGS ARE TO FACE OF STUD, OR FACE OF FOUNDATION UNLESS OTHERWISE NOTED. 7. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE SAME AS FOR OTHER SIMILAR WORK. 8. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 9. CONTRACTOR SHALL VERIFY ALL "BUILDING STANDARDS" WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHERE SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF WORK. CONTRACTOR SHALL REQUEST VERIFICATION FROM UTILITY COMPANIES OF UNDERGROUND UTILITY LOCATIONS PRIOR TO BEGINNING EXCAVATIONS. 1 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. 12. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 13. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. 14. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 15. OWNER SHALL PROVIDE BUILDING PERMIT TO THE CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. 16. CONTRACTOR SHALL SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE, CONSTRUCTION, LABOR, HEALTH AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS FORWARDING PROOF OF SUCH ACTION TO THE OWNER PRIOR TO COMMENCEMENT OF CONSTRUCTION. 17. CONTRACTOR SHALL SECURE AND PROVIDE ALL PERMITS FOR OCCUPANCY, UTILITIES AND ANY OTHERS REQUIRED BY GOVERNING AUTHORITIES BEYOND THE BASIC BUILDING PERMIT, MAKING TIMELY APPLICATIONS AND INQUIRIES, PAYING ALL FEES AND POSTING ALL BONDS TO BE RELEASED AT THE COMPLETION OF CONSTRUCTION. 18. CONTRACTOR SHALL PROVIDE DRAWINGS, SHOP DRAWINGS AND CALCULATION AS REQUIRED FOR OWNER APPROVAL AND PERMITTING OF THE FIRE ALARM DETECTION / MONITORING SYSTEM, HVAC SYSTEM, AND ALL OTHER SYSTEMS REQUIRING BIDDER DESIGN. SUCH REVIEW AND APPROVAL SHALL BE BY THE OWNER. ALLOW A MINIMUM OF TWO WEEKS FOR REVIEW. \OTES SCALE - MIRROR OF LAV. `-- SANITATION CONSTRUCTION MIN. 2' -0" @ FRONT & SIDE, TYP. z 0 Cr) N TYP. TOILET ELEVATIO\ SCALE 3/8 " =1' -0" ACCESSIBLE LAVATORY W/ GRAB BAR INSULATED BOOT OVER PIPES c LAV c_ OF WATER CLO'ET TYP. 6" COVE UP, NO RUBBER BASE ALLOWED. WOOD TRIM N) 5A 00 N) W • ctt. MIN. 6 " -18' MIN. /MTN. 2' -O" 12" 16"-18" A FRONT TYP. TOILET ELEV. SCALE 3/8 " =1' -0" 19. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA, AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. THESE MODIFICATIONS SHALL BE TRANSFERRED TO A SET OF REPRODUCIBLES AND GIVEN TO THE OWNER PRIOR TO FINAL PAYMENT. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETE. 21. ALL WORK SHALL BE GUARANTEED FOR THE PERIOD OF ONE (1) YEAR AFTER COMPLETION UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 22. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE, VIBRATION, HAZARD OR OTHER CAUSES. IN ADDITION, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OR VIBRATION. ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST, DEBRIS, AND CONSTRUCTION MATERIALS AT ALL TIMES. 23. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE '06 I.B.C. 24. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. 25. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE '06 I.B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS (42 CFR 1426; 16 CFR PART 1201) 26. THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 27. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. 28. ELECTRICAL ROUGH -IN AND REFLECTED CEILING PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED. 29. EXIT SIGNS AND EMERGENCY EXIT ILLUMINATION SHALL CONFORM TO THE '06 I.B.C. CHAPTER 10 AND JURISDICTION FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTNING AS REQUIRED BY THE JURISDICTION FIRE AND BUILDING DEPARTMENTS. CONFIRM ACCEPTABILITY OF LOCATIONS WITH OWNER'S REPRESENTATIVE BEFORE INSTALLATION AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS 30. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 31. FIRE EXTINGUISHERS: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED BY NFPA 10 MOST RECENT EDITION AND APPROVED BY FIRE DEPARTMENT. CONFIRM ACCEPTABILITY OF LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 32. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN NFPA STANDARD 30 AND THE CURRENT UNIFORM FIRE CODE. PERMIT MAY BE REQUIRED. 33. ALL DRAPES, HANGINGS, CURTAINS, DROPS, AND ALL OTHER DECORATIVE MATERIALS, THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NON- FLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHALL. PROVIDE A CERTIFICATION TO THIS EFFECT. B. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. C. MINIMUM FLAME SPREAD CLASSIFICATION OR INTERIOR FINISHES SHALL BE PER TABLE 803.5 OF '06 I.B.C. N rn oo 0 ) r) N) 2 c 39 " -41" MAX 42" MIN -9 " z SEAT B SIDE 56 MIN FOR TYPE 1 STD. ST ALL COVER DISP. 5B P A ; REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SCALE 3/8 " =1' -0" LAVATORY D IAG RA FACE OF WALL V 34. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER '06 I.B.C. SECTION 803.9, AND GWB. CEILING SHALL BE INSTALLED PER '06 IBC SECTION. 2504, 2508.5 35. THE LIVE LOADS FOR EACH FLOOR, OR PART THEREOF, WHICH HAVE BEEN DESIGNED FOR A COMMERCIAL OR INDUSTRIAL BUILDING, SHALL BE CONSPICUOUSLY POSTED BY THE OWNER IN THAT PART OF EACH STORY IN WHICH THEY APPLY USING DURABLE METAL SIGNS. IT SHALL BE UNLAWFUL TO REMOVE OR DEFACE SUCH NOTICES. THE OCCUPANT OF THE BUILDING SHALL BE RESPONSIBLE FOR KEEPING THE ACTUAL LOAD BELOW THE ALLOWABLE LIMITS. 36. SOUND INSULATE ALL PLUMBING WALLS AND LINES. 37. ALL GYPSUM WALLBOARD SHALL BE 5/8, TYPE "X" UNLESS NOTED OTHERWISE. 38. TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA COMMUNICATIONS CABLING SYSTEM. CONTRACTOR TO COORDINATE TIMING AND OTHER REQUIREMENTS WITH TENANT. 39. PROVIDE AS -BUILT MODIFICATIONS TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE AND SMOKE MONITORING DETECTION SYSTEMS ON REPRODUCIBLES SUPPLIED BY THE OWNER. SUCH AS -BUILT DRAWINGS WILL BE COMPLETED, SUBMITTED AND APPROVED BY THE OWNER PRIOR TO TO THE FINAL PAYMENT. 40. PROVIDE BLOCKING IN ALL WALLS TO SUPPORT CABINETRY, SHELVING, BATHROOM FIXTURES, DISPLAY RAILS AND ALL OTHER EQUIPMENT OR IMPROVEMENTS AS REQUIRED. 41. THE CONTRACTOR SHALL CONSULT ALL PLANS AND DRAWINGS OF ALL TRADES FOR OPENINGS THROUGH SLABS, FLOOR SYSTEM, ROOF SYSTEMS, WALLS, CEILING AND CHASES FOR CUTS, PIPES, CONDUITS AND EQUIPMENT; AND SHALL VERIFY SIZE, WEIGHT AND LOCATION WITH RESPECTIVE SUBCONTRACTORS. 42. ALL WORK PERFORMED BY ALL SUBCONTRACTORS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 43. PROJECT OWNER AND CONTRACTOR TO VERIFY HAZARDIOUS MATERIALS AS NECESSARY, SUCH AS ASBESTOS, AND HIRE SPECIAL CONSUNTANT AND CONTRACTOR(S) BEFORE PERFORMING REGULAR CONSTRUCTION WORKS. 44. CODES AND REGULATIONS ON "ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES" ARE COMPLIED BY ICC /ANSI. A117.1 -2003. IF THERE ARE DISCREPENCIES, NOTIFY ARCHITECT IMMEDIATELY FOR CORRECTIONS. 18" Milk /, • • MIR x N 0 �r- LAV. N N ROR WALLS WITHIN 2 FT. OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 FT. ABOVE THE FLOOR. TEMPERATURE SHIELDING FRONT ELEVATION SEPARATE PERMIT REQUIRED FOR: Mechanical Ri Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION x N) PROJECT DESCRIPTION CONDITIONAL USE PERMIT FOR: TENANT IMPROVEMENT (T.I.) WORK FROM CASINO (A -3) TO MOSQUE (A -3) PROJECT ADDRESS: 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 MUHAMMAD JALYALAR: 206) 799 -1379 PARCEL TAX NO: 161000 0125 SEC /TOWNSHIP /RANGE: SW 15 23 4 LEGAL DESCRIPTION CLARKS JAMES GARDEN ADD E 5 FT OF LOT 4 TGW ALL LOTS 5 & 6 TGW N 89 FT OF LOT 1 TGW N 100 FT OF LOT 12 - PORTION OF PARCEL A OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L99 -0072 RECORDING NO 19991007002061 ZONING: NCC LAND USE: COMMERCIAL CODE: '06 IBC OCCUPANCY: A -3 OCCUPANT LOAD: SEE BELOW TYPE OF CONSTRUCTION: V -B, SPRINKLER OCCUPANCY SUMMARY: (SEE FL. PLAN) SEE A2.1 OCCUPANCY SUM. PLUMBING SUM. ('06 IBC TABLE 2902.1): SEE A2.1 OCCUPANCY SUM. ""- City Of fu Wily BUILDING .. WSION PARKING: 1 PER EVERY 4 FIXED SEATS OR 100 SF OF ASSEMBLY AREA LOT SUMMARY: SPRINKLER: EXIST, MODIFY PER NEW WALL LOCATION HVAC SYSTEM (HEATING & COOLING): DEFERRED (A SEPERATE PERMIT BY CONTRACTOR AS REQ'D) MECH (HVAC) /ELEC. /PLUMB. /FIRE ALARM /SPRINKLER PERMITS: DEFERRED (A SEPERATE PERMIT BY CONTRACTOR AS REQ'D) PROJECT INFORVATION SCALE - CODE SUMMARY 7"" MIN FACE OF WALL SIDE ELEVATI O REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2008 TEMPERATURE HIELDING KICK SPACE 1 PROPERTY OWNER ('S REPRESENTATIVE) ABU -BAKR ISLAMIC CENTER 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 T: 206) 799 -1376 PROJECT OWNER ('S REPRESENTITIVE): MUHAMMAD JALYALAR: T: 206) 799 -1379 1954 UNION AVE NE., RENTON, WA 98059 GENERAL CONTRACTOR: TBD ARCHITECT: NW ARCHITECTURE 3828 4TH AVE S. SEATTLE, WA 98134 T: (206) 355 -9686 - YOUNG KIM, AIA TABLE OF CONTENTS: A1.1: PROJECT INFO., VICINITY MAP, NOTES, BATHROOM DETAILS A1.2: SITE PLAN A2.1: FLOOR PLAN, SCHEDULES, NOTES, WALL SEC., WASHROOM A2.2 .: ENLARGED PLAN -NORTH A2.2A: ENLARGED PLAN -SOUTH A2.3 DEMO. PLAN A2.4: FIRE EXIT PLAN A3.1: ELEV. (NO CHANGE) A4.1: REFLECTED CLG. PLAN L -1: LANDSCAPE PLAN L -2: IRRIGATION PLAN L -3: IRRIGATION DETAILS 2 \OT USED J SCALE - C S 140TH ST. VINCI \ITY SCALE N.T.S. t O 8 13 9 S 142TH ST. w TOILET PAPER DISPENSERS SHALL BE MIN. 7" TO MAX. 9" IN FRONTOF THE TOILET. THE OUTLET OF THE DISPENSER SHALL BE 15" MIN. TO 48" MAX. ABOVE FLOOR. THERE SHALL BE A CLEARANCE OF 1.5" MIN. BELOW AND 12" MIN. ABOVE THE GRAB BAR. OTHER DISPENSERS AND DISPOSAL FIXTURES SHALL BE LOCATED 40" MAX. ABOVE THE FLOOR OR GROUND TO ANY RACK, OPERATING CONTROL, RECEPTACLE OR DISPENSERS. FLOORS, TOILET AND BATH RM. FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 FT. ABOVE THE FLOOR. z 1 :1M-H S 141 TH ST. VAR 6 "x14 GA PLATE NOTCHED INTO STUDS 3/8" 0 TOGGLE BOLT ELEV. Pe Plar revle approval Is subject to errors and omissions. Approval o construction documents does not authorize the violation of any adopted code orr o Receipt of approved Field Copy and con / is acknowled By Date: ,. 71 77eL , r` I FIL C It No. Clay of Tukwila BUILDING DIVISION REVISION PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL., BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 - 1379 GRAB BAR SCALE 3/8 " = 1' REGISTRATION NWA PROJECT NO. DRAWN BY SCALE TITLE NUMBER PERMIT SET Ameramisososrmommesasurou NW ARCHITECTURE A R C H I T EC Y U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9 = 0 OF `WASHINGTON RECEIVED SEP,19 2008 PERM CENTEF hl . DATE 301 -305 CHK BY YK • 9/18/2.008 AS NOTED PROJECT INFO., MAP, NOTES,;ESTROOM DTLS iziermancv Al L COPY RICH TIGHTS RFS n GARAGE 5.00' N87 ° 11'08 "W EXIST. LANDSCAPE TO REMAIN W/O CHANGE RASH ENCLOS PROJECT BLDG. 14,360 SF COVERED EV 1,436 SF LANDSCAPE AREA (TYP.) EXIST. BLDG. (PAWN X- CHANGE) 4,908 SF EXIS . BUS SHE TER EXIST. LANDSCAPE w to ° z SITE PLAN N 87 ° 11'06" W SCALE 1 "= 20' - 0" 501 SF N C.L. OF\14 ST ST. PEDESTRIAN CONNECTION N 87 ° 11'06" W FOG LINE, SEE SECTION AND ENLARGED PLAN. STOPPERS FENCE "C" CURB NOTE: 1. LANDSCAPE PLAN: SEE LANDSCAPE DWG. 2. TRIP GENERATION & PARK'G ANALYSIS: BY ENG., SEE THE SUBMITTED. a a DR)VE ,WAY 50 50 CO -J z 0 NN w -J -§" LL au 4" SOLID WHITE THERMOPLASTIC FOG LINE PER WSDOT SPEC.. EXACT FOG LINE LOCATION TO BE DETERMINED AND APPROVED IN THE FIELD BY PUBLIC WORKS PROJECT INSPECTOR BASED ON TEMPORARY PAVEMENT MARKING," VARIES zy KNOX BOX: PER PH. MTG. W/ FIRE DEPT. BY YKIM 11.20.08 GET A SEPARATE PERMIT FROM FIRE DEPT. FOR KNOX BOX AND OTHER FIRE RELATED ISSUES BY CONTRACTOR. KNOX BOX: 1- 800 - 552 -5669 KNOX CODE NO.: PS -10- 275 -12 -06 MODEL NO. /PART NO.: 3261 BLACK LOT S U M v1ARY: LOT SIZE: TOTAL BLDG AREA: MOSQUE: - PORCH - PAWN SHOP: TOTAL: BLDG AREA: LAN DSCAPE AREA: PARKING LOT ISLAN (200 SF: UP TO 40 LOTS 900 SF: 60 PAR<'G STALLS x 15 SF /EA) 1,100 SF REQ'D TOTAL: 11,:411, "1.011 4" SOLID WHITE THERMOPLASTIC FOG LINE, SEE NOTE AT SECTION, TYP. PLAN VIEW 11.00' 20' HALF RIGHT 89,101 SF 14,360 SF 1,436 SF 4,908 SF 20,70L SF 23.2 9,261 SF 5: 2,793 SF 12,439 SF PROV'D (13.7 % OF LOT SIZE) N �- OF WAY rcr.VbvftL FOR CODE COMPLIANCE APPROVED DEC 2 6 2003 City Of Tukwila 3 UILDING DWISION N.T.S. EX. PAVED SURFACE 9.00' 4 -INCH "C" CURB (TYP,) 1r; -% / /// /f /, REMOVE EXISTING PAVEMENT UNDER THE LANDSCAPE AREA AND FILL WITH NATIVE SOIL. SECTION @ S. 141ST. STREET N.T.S. Final acceptance is subject to field inspection by the Public Works utilities inspector. Date: By /2/ (Y5 CORRECTION L IR &.. 08 -L-13 RECEIVED DEC 1020 PERMIT CENTER 12/9/08 plans have been reviewed by the Public \\'orks Department for conformance with current City standards. Acceptance is subject to errors ar omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequac - of the design rests totally with tl designer. Additions, deletions - or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. 1 --.. LANDSCAPE NO. REGISTRATION 5.00' iii REVIEW COMMENTS REVIEW COMMENTS REVISION PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6. 3 55.9 6 8 6 REGISTERED ARCHITECT STATE OF WASHINGTON NWA PROJECT NO. w DRAWN BY DATE SCALE TITLE NUMBER 9/18/ AS NOTED SITE PLAN 12/9/08 10/21/08 DATE PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 301- -305 CHK BY YK 2008 A1 ALL COPY RICHT RIGHTS R S WED ase HEIGHT ABOVE FLOOR TO BASELINE OF CHARACTER HORIZONTAL VIEWING DISTANCE MINUMUM CHARACTER HEIGHT 40" (1015 MM) TO LESS THAN (1780 OR EQUAL TO 70" 1780 MM) LESS THAN 6' -0" (1830 MM) 5/8" (16 MM) 6' -0" 1830 MM) AND GREATER 5/8" (16 MM), PLUS 1/8" (3,2 MM) PER FOOT (305 MM) OF VIEWING ABOVE C-0" (1830MM) GREATER THAN 70" (1780 MM) TO LESS THAN OR EQUAL TO 120" (3050 MM) LESS THAN 15' -0" (4570 MM) 2" (51 MM) 15' -0" (4570 MM) AND GREATER 2" (51 MM), PLUS 1/8" (3.2 MM) PER FOOT (305 MM) OF VIEWING DISTANCE ABOVE 15' -0" (4570 MM) GREATER THAN 120" (3050 MM) LESS THAN 21' -0" (6400 MM) 3" (76 MM) 21' -0" (6400 MM) AND GREATER 3" (76 MM), PLUS 1/8" (3.2 MM) PER FOOT (305 MM) OF VIEWING DISTANCE ABOVE 21' -0" (6400 MM) NOT USED SCALE v v • 00 0 • ° p 00000 i4 0_0 o r o�C o• • " !o . o o , eoOg 0. 5 I — YP. PIPE BOLLARD SCALE 3/4 " =1' -0" (--- TEXTURED CONC. PATTERN EXTERIOR WALL 6" CONC. CURB (TYPICAL) 6"0 STL PIPE, CONC FILLED & CAPPED 2' DIAMEI ER CONC FOOTING Ar SLOPE CURB : ACC /ANSI A117.1 -2003 TABLE 703.2.4 — VISUAL CHARACTER HEIGHT 703.3.1 GENERAL. TACTILE CHARACTERS SHALL COMPLY WITH SECTION 703.3, AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION 703.4. 703.3.2 DEPTH. . TACTILE CHARACTERS SHALL BE RAISED 1/32" (0.8 MM) MIN. ABOVE THEIR BACKGROUND. 703.3.3 CASE. CHARACTERS SHALL BE UPPERCASE. 703.3.4 STYLE. CHARACTERS SHALL BE SANS SERIF. CHARACTERS SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. 1:12 M 4" CONC WALK REINFORCING MESH #4 CONT TOP & BTM 000 °a000a 0000 , MIN. 4' -0 " ACCESSIBLE CURVE CUT SCALE 1/4 " =1' -0" IIIIIIIIIIIIIIIIIIIIIIIIl111 ,111111111:911111111111 11111111111 • co .O O 0 0 ° 0G ^rpo 6 TYP 8" CURVE/ DRIVE SCALE 3/4 " =l' —O" SECTION Oo 00 o o o ro „ PLAN TRUNCATED DOMES 1:12 A CONSTRUCTION JNT EASE EDGE AC PAVEMENT CHAPTER 7 - ICC /ANSI A117.1 -2003 ti LVTIME111 E co FIG. 703.3.5 CHARACTER HEIGHT SLOPE CURB O „ ////////////// / / / / / / / / / / / / / / / / / / / / / // / / / / /// ELEVATION 2" CLEARANCE / (TYP.) ( # BARS • 6" 8" MIN. 10" MAX : ° pm o 04 0,1) 4 CURVE/ PLANTER SCALE 3/4 " =1' -0" HOLES PLAN 3:1 SAND & CEMENT GROUT 1" DEPTH A. CONC. #4 CONT PAVEMENT TOP & BTM (2) #3 BARS 6' -0" (2) #6 BARS SECTION CO \CRETE STOPPER SCALE 1"=1' —0" EASE EDGE co me 111►111111111111111111111 I X llllllllll111IIIllillll � ' Oo 000000 �• . -0 " 9, .., 9 / CONC. PAVEMENT W/ THICKENED EDGE, TYP. A/C PAVEMENT W/ THICKENED EDGE, TYP. CONC./ A/C PAVEMENT SCALE 3/4 " =1' -0" rn 703.3.5 CHARACTER HEIGHT. THE UPPERCASE LE. IIER "I" SHALL BE USED TO DETERMINE THE ALLOWABLE HEIGHT OF ALL CHARACTERS OF A FONT. THE HEIGHT OF THE UPPERCASE LETTER "I" OF THE FONT, MEASURED VERTICALLY FROM THE BASELINE OF THE CHARACTER, SHALL BE 5/8" (16 MM) MIN., AND 2" (51 MM) MAX. EXCEPTION: WHERE SEPARATE TACTILE AND VISUAL CHARACTERS W/ THE SAME INFORMATION ARE PROVIDED, THE HEIGHT OF THE TACTILE UPPERCASE LE.I I ER "I" SHALL BE PERMITTED TO BE 1/2" (13 MM) MIN. 703.3.6 CHARACTER WIDTH. THE UPPER CASE LEI IER "0" SHALL BE USED TO DETERMENT THE ALLOWABLE WIDTH OF ALL CHARACTERS OF THE FONT. THE WIDTH OF THE UPPERCASE LE I I ER "0" OF THE FONT SHALL BE 55% MIN. AND 110% MAX. OF THE HEIGHT OF THE UPPER CASE "I" OF THE FONT. 703.3.7 STROKE WIDTH. TACTILE CHARACTER STROKE WIDTH SHALL COMPLY WITH SECTION 703.3.7. THE UPPERCASE LEI I ER "I" OF THE FONT SHALL BE USED TO DETERMINE THE ALLOWABLE STROKE WIDTH OF ALL CHARACTERS OF A FONT. 703.3.7.1 MAXIMUM. THE STROKE WIDTH SHALL BE 15% MAX. OF THE HEIGHT OF THE UPPERCASE "I" MEASURED AT THE TOP SURFACE OF THE CHARACTER, AND 30% MAX. OF THE HEIGHT OF THE UPPERCASE LETTER "I" MEASURED AT THE BASE OF THE CHARACTER. 703.3.7.1 MINIMUM. WHEN CHARACTERS ARE BOTH VISUAL AND TACTILE, THE STROKE WIDTH SHALL BE 10% MIN. OF THE HEIGHT OF THE UPPERCASE LEI IER "I ". 703.3.8 CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS OF ADJACENT TACTILE CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL TACTILE CHARACTER SHALL BE 1/8" (3.2 MM) MIN. MEASURED AT THE TOP SURFACE OF THE CHARACTERS, 1/16" (1.6 MM) MIN. MEASURED AT THE BASE OF THE CHARACTERS, AND FOR TIMES THE TACTILE CHARACTER STROKE WIDTH MAXIMUM CHARACTERS SHALL BE SEPARATED FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8" (9.5 MM) MIN. NOTES: SEE SITE PLAN FOR HANDICAPPED PARKING LOCATION STATE DISABLED PARKING PERMIT REQUIRED II VAN ACCESSIBLE v 8" MIN SCALE 1"=1'-0" ACCESSIBLE PAR —PUT ONLY @ VAN PARKING LOT PROPOSED GRADE r. 10/21/08 KING SIGN a PROPOSED GRADE V N STATE DISABLED PARKING PERMIT REQUIRED 4. 8" MIN. N 0) 703.3.9 LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF TACTILE CHARACTERS WITHIN A MESSAGE SHALL BE 135% MIN. AND 170% MAX. OF THE TACTILE CHARACTER HEIGHT. 703.3.10 HEIGHT ABOVE FLOOR. TACTILE CHARACTERS SHALL BE 48" (1220 MM) MIN. ABOVE THE FLOOR, MEASURED TO THE BASELINE OF LOWEST TACTILE CHARACTER AND 60" (1525 MM) MAX. ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST TACTILE CHARACTER. EXCEPTION: TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 703.3.10. 703.3.11 LOCATION. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE, LEAF. WHERE A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAVES, THE SIGN SHALL BE TO THE RIGHT OF THE RIGHT —HAND DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE OF A SINGLE DOOR, OR TO THE RIGHT SIDE OF DOUBLE DOORS, SIGNS SHALL BE ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR AREA 18" (455 mm) MIN. BY 18" (455 MM) MIN., CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45° OPEN POSITION. EXCEPTION: SIGNS WITH TACTILE CHARACTERS SHALL BE PERMITTED ON THE PUSH SIDE OF DOORS WITH CLOSERS AND WITHOUT HOLD —OPEN DEVICES. 703.3.12 FINISH AND CONTRAST. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NONGLARE FINISH. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND, OR DARK CHARACTERS ON A LIGHT BACKGROUND. EXCEPTION: WHERE SEPARATE TACTILE CHARACTERS AND VISUAL CHARACTERS WITH THE SAME INFORMATION ARE PROVIDED, TACTILE CHARACTERS ARE NOT REQUIRED TO HAVE NONGLARE FINISH OR TO CONTRAST WITH THEIR BACKGROUND. AREA OF REFUGE 00'8•431 FIG. 703.3.10 HEIGHT OF TACTILE CHARACTERS ABOVE FLOOR OR GROUND cCEss i 131_ a - 14.T. AREA OF REFUGE INTERNATIONAL SYMBOL OF ACCESSIBILITY: PAINTED SYMBOL: WHITE TRAFFIC PAINT 3" MIN. WIDE STRIPE PAINTED FIELD: BLUE TRAFFIC PAINT 3 —0" SQUARE WITH 3" RADIUS CORNERS NJ z E 0 N N 00 C 4- ACCESSIBLE PAR SCALE 1 " =1' -0" 2' -8 1/4" EQ. TO EDGE OF STALL BACK EDGE OF STALL OF STALL & SYMBOL EQ. TO EDGE OF STALL NOTES: 1. SEE SITE PLAN FOR HANDICAPPED PARKING LOCATIONS. 2. SIGNAGE SHALL CONFORM TO THE WASH. STATE ADMIN. CODE RECEWEP OM 2 9 2000 PERMIT CENTEr KING SIGN NO. REVIEW COMMENTS REVISION 10/21/08 DATE PROJECT TITLE /OWNER ABU —BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799- 1379 PERMIT SET �cV1tWLI.) rvp, CODE COMPLIAPf CE DEC 2 6 2008 DIVI fO NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 REGISTRATION 8171 ( • REGISTER D ARCHIT !' 0 WASHING ON NWA PROJECT NO. Ld DRAWN BY DATE SCALE TITLE NUMBER 301 -305 CHK BY YK 9/18/2008 AS NOTED DETAILS A1.3 ALL COPY RIGHT RIGHTS RESERVED STUDY 8 COMM. SVC. 1840 SF OCCU:1 23 STUDY 5 STUDY 6 PPLY SF STUDY 7 D112 HALL 77 SF VENT TO OUTSIDE (50 CFM) VENT TO KITCH. (BREAK) ®OUTSIDE (100 CFM) 5' -0 BATH / / / / / // / / / / / / / (/ / /0/ / / ° 7 / P3•, 83hv 0 x'oSF •snP ' OCCa2J'SF: L�'.5!] PR U 2 Y L OFC -IMAM OFC (AC COAT 85 SF POST SIGN © DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 130." 31' -2 3/4" EXIST. CANOPY_ POST SIGN © DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 252." 64 -1 1/4" POST SIGN @ DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 543." UTIL. H 15 SF FLOOR PLAN SCALE 1/8 " =1' -0" VENT TO OUTSIDE - / (50 CFM) STUDY 1 94 SF HALL 522 SF DRINK'G FNTN . EXIST. ELEC. 111 SF MOP SINK F. WASH 359 SF VENT TO ' OUTSIDE (50 CFM) GROSS FL. AREA: 14,310 SF (FRONT EVE: NOT INCLUDED): 1,431 SF EXIST. BOILER 62 SF r� 7 --- DRINK'G FNTN HALL 242 SF D112 M. WASH 125 SF FI HALL 218 SF r VENT TO OUTSIDE -, (125 CFM EA.) VENT TO OUTSIDE (50-0) DRINK'G FNTN NOTES 1. ALL LUMBERS IN CONTACT WITH CONC. TO BE PRESSURE TREATED. 2. NO STRUCTURAL CHANGES. 3. NO CHANGES AT EXTERIOR. 4. SEPARATE MECH. /ELEC. /FIRE PERMIT TO BE APPLIED. 5. A SEPARATE SPRINKLER PERMIT BY CONTRACTOR TO BE APPLIED AS NECESSARY. 6. SEE FIRE EXIT PLAN (A2.4) FOR EXIT LIGHT INSTALLATIONS. 7. ALL EXIT LIGHTS AND FIRE ALARM SYSTEMS TO BE DONE BY LICENSED CONTRACTOR. 8. ALL DOOR HARDWARES TO BE LEVER TYPE AS REQUIRED, TYP., BALDWIN 5460 OR BETTER. 9. MIN. 50 CFM AT BATHROOM, TYP. SEE FL. PLAN FOR REQ'D CFM. 10. NO COOKING AT KITCHEN /BREAK RM. 11. EXIST. PLUMBING FIXTURES TO REMAIN WITH NECESSARY REPAIR WORKS. 12. A SEPARATE PLUMBING PERMIT FOR THE NEW WORKS TO BE APPLIED. 13. ALL EXIT DOORS TO HAVE PANIC HARDWARE, TYP. t4. .5e. AZ.2, A2.2� � Moi�lr o�TAIL IN FO or OFC. -ADMIN 2 190 SF OFC.- ADMIN. 1 170 SF CORR. 145 SF NEW CONSTRUCTION OCCUPANCY SUMMARY ROOM SQFT. OCCU. PRAY /WORSHIP 3,801 543 MULTI /W. PRAY 1,763 252 COMM. SVC. (15) 1,840 123 TOTAL STUDY (20) 1,273 64 TOTAL OFC. 1,342 14 TOTAL STORAGE 50 1 KITCHEN 260 2 SUPPLY 95 1 TOTAL ENT. 274 - BOILER /ELEC. 173 1 TOTAL HALLWAYS 1,311 - TOTAL BATH 596 - F. /M. WASH 484 - SUBTOTAL 13,262 1,001 MALE FEMALE W.C. LAV. W.C. LAV. REQ'D 4 2 4 2 (PRINCIPAL ASSEM. AREA) REQ'D 1 1 2 1 (ED. & ACT. AREA) TOTAL REQ'D 5 3 6 3 TOTAL PROV'D 7 5 6 5 DOOR SCHEDULE NO. SIZE(W x H) INT D101 3 x 7' -0 YES D 102 D103 D104 D105 D106 D118 \� U D 7' -4 x 7' -0 NO WINDOW SCHEDULE NO. SIZE(W X H) INT W101 4' -0 X 4' -0 YES W102 W103 W104 W105 U W106 5' -0 X 4' -0 W107 W108 U W109 4' -0 X 4' -0 W110 4' -0 X 4' -0 v EXIST. CON STRUCTION TYP. WALL SCALE 1 1/2"=1' -0" SCALE 3/8 " =1' -0" ROOF ASSEMBLY 3/8" DEFLECTION SPACE FIRE STOP SEALANT AT FIRE RATED PARTITIONS., TYP. ACOUSTICAL SEALANT AT SOUND RATED PARTITIONS, TYP. LOCATED AT INNER LAYER OF GWB 5/8" TYPE 'X" GWB ON BOTH SIDES (USE WATER RESISTANT BOARD AT KITCHEN AND BATH RM.) FIRE BLOCKING AT MID OF WALL METAL STUDS © 16" O.C. GALVANIZED MTL STUDS WHERE IN CONTACT W/ CONC., TYP. KICVItlitftU t-UK CODE COMPLIANCE APPROVED DEC 2 6 2OO8 EGRESS WIDTH PER OCCU. SERVED (TABLE 1005.1): 0.15 x 130 =. 19.5" . REQ'D OCT 2 9 2000 PERMIT CENTER S.D.: SOUP DISPENSER P.T.D.: PAPER TOWEL DISPENSER REVIEW COMMENTS REVISION PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6. 3 5 5. 9 6 8 6 REGISTRATION 8A 71 REGISTERED / ARCULTECV NWA PROJECT NO. DRAWN BY SCALE TITLE NUMBER 9/18/2008 AS NOTED FLOOR PLAN, WALL SEC] WASHROOM ELEV. ALL COPY RIGHT RIGHTS RESERVED �I I SHEEP I NWA PROJECT NO. Olik o� , G7 D , _„, o rn (74 o z A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 NUMBER TITLE SCALE DATE DRAWN BY REVIEW COMMENTS A2.2 ALL COPY RICHT RIGHTS RESERVED ENLARGED FLOOR PLAN AS NOTED 9/18/2008 CHK BY I 10/21/081 YK I. (EXIST.) 70 SF 7" : F (BREAK) ENO M 7111 0 FD FA: 799 SF 2' -6" / // EXIST. ENT. 100 SF VENT TO FD OUTSIDE (100 CFM) „ 0 -0” 5 -0" B. 53 SF VENT TO OUTSIDE (50 CFM) DIAPER \ VENT TO OUTSIDE (100 CFM) CNI 3 -0" O D118 r WH EXIST. BOILER 62 SF I, D11 DRINK'G FNTN HALL 242 SF 6' -8 1/2" 0 N N N OFC. (ACCOUNT) ▪ 85 SF N N N N N N N V) / i / OFC. (AUDIO) 140 S EXIST co D115A 11 '— " \\\ \\\ \N\\ \\\ FLOOR PLA\ SCALE 1/4 " =1' -0" UTIL. 15 SF HALL 218 SF 3 ' -5 3/4" 2' -6" 9" 3' -0" / VENT TO MALE WASH o OUTSIDE 125 SF FD (50 CFM) / 3' -0" 4' VENT TO OUTSIDE (125 CFM) M. (EXIST.) 267 SF 0 10/21/08 —10" N VENT TO OUTSIDE (50 CFM) ENT. 82 SF 0 FD 5' -5 1/2" 3' -0" 5' -0' M 53 SF VENT TO OUTSIDE (125 CFM) o) ACCESSIBLE BATHROOM SIGNAGE, SEE TABLE ON A1.3 0 3' -10" / I / / PRAY /WORSHIP 3,830 SF / /CCU: 543 ' NET PRAY AREA: 2,422 SF / / / C:5 DRINK'G FNTN \ o � N) 1 N - 13' -5 1/2" OFC. —ADMIN 2 190 SF OFC. —ADMIN 1 170 SF 0 I 0 I / 13' -2 1/4" 16' -6 1/4" CORRIDOR 145 SF N) 5' -0" 3' -0" 4'' 10/21/08 OFC. —IMAM 161 SF lea I t= el 1:3 rf t\, n i 10 El op 0 z two a ril f CD z r) M 9111]0 !Mind SHEET NWA PROJECT NO. 4 D = \ _ (7 rn M - M A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 NUMBER TITLE SCALE DATE DRAWN BY REVISION REVIEW COMMENTS A2.2A ALL COPY RIGHT RICHIS RESERVED ENLARGED FLOOR PLAN AS NOTED 9/18/2008 CHK BY 301 -305 10/21/081 YK t7"' 0 co r STUDY STUDY 8 145 SF CONF.OFC. 1 175 SF OFC. 2 99 SF OFC. 3 99 SF STUDY 2 144 SF OFC. 4 132 SF HALL 522 SF STUDY 4 189 SF STUDY 6 188 SF i 16' -9" LACCESSIBLE BATHROOM SIGNAGE, SEE TABLE ON A1.3 STUDY 5 188 SF COMM. SVC. 1,840 SF OCCU: 123 VENT TO OUTSIDE (50 CFM) DRINK'G FNTN UNISEX 53 SF HALL 107 SF 0 STUDY 7 169 SF ACCESSIBLE BATHROOM SIGNAGE, SEE TABLE ON A1.3 WOMEN 170 SF D110 6'{ 4' -O" HALL 77 SF OFC. 91 SF D112A ACCESSIBLE BATHROOM SIGNAGE, SEE TABLE ON A1.3 VENT TO OUTSIDE (100 CFM) STOR. 50 SF 9, -5" FLOOR PLA\ SCALE 1/4 " =1' -0" 0 , 0 W. (EXIST.) 170 SF KITCH. (BREAK) 209 SF / � i l � MULTI (W. PRAY 1,763 SF OCCU: 24 NET PRAY AREA: 799 SF EXIST. ENT. 100 SF 2' -6" 9" 3' -0" VENT ° ED OUTSIE (100 t VENT OUTSI (50 C VEN1 OUT (100 5 E C C O O O 0 O DEMO PLAN 0 SCALE 1/8 " =1' -O" ®®® O o Q m O ® a uu DEMO EXIST. CONSTRUCTION CODE COMP 4 N, APPROVED I DEC 2 6 2 0 1 13 City or Tukwila URDIRO DIMStoo b0 &43`1 v®® NO. REVISION PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 REGISTRATION 8171 REGISTERED ARCHITECT/ • TATE 'F WASHINGT N SEP 19 2000 PERMIT CENTEF NWA PROJECT NO. 301 -305 DRAWN BY DATE SCALE TITLE NUMBER CHK BYf YK 9/18/2008 AS NOTED DEMO PLAN A2.3 L CO 'Y RIGHT RIGHTS R S RVED 41 I an EXIT SIGN N EW CONSTRUCTION ---- EXIST CONSTRU IDOS -439 rs !E C %JED ocr 292008 PERMIT CENTER F A REVIEW COMMENTS 10/21/08 NO. REVISION DATE PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 PERMIT SET NW ARCHITECTURE ARCHITECTURE 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6 . 3 5 5 . 9 6 8 6 REGISTRATION 8171 REGISTERED / ARC ITE / .4 i kl i STATE OF WASHIN ON NWA PROJECT NO. 301-305 DRAWN BY - CHK BY YK DATE 9/18/2008 SCALE AS NOTED TITLE FIRE EXIT PLAN NUMBER A2 .4 ALL COPY RIGHT RIGHTS RESERVED 41 I an EXIT SIGN N EW CONSTRUCTION ---- EXIST CONSTRU IDOS -439 rs !E C %JED ocr 292008 PERMIT CENTER F cD N EAST ELEVATION SCALE 1/8"=1' -0" (Th \ORTH ELEVATION 2 SCALE 1/8"= 1' -0" C WEST ELEVATION 3 SCALE 1/8"= 1' -0" - ) \1.) k tiit l `" 8" HEIGHT LL I I ERINGS TYP. cc _ Nt Vi 0 ii-uk CODE CO /to MPLIA A PPROVED NCE DEC 2 6 2008 City Of NO. PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 PERMIT SET NW ARCHITECTURE ARCH I T EC T UR E 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6 . 3 5 5 . 9 6 8 6 REGISTRATION 8171 REGISTERE ARCHITE U KIM STATE OF WASHINGTON NWA PROJECT NO. DRAWN BY DATE SCALE TITLE NUMBER REVISION RECE WED SEP, 1 9 2006 PERMIT CENTER ELEV. 9/1 AS NOTED A3.1 DATE 301-305 CHK BY YK ,-.11 COPY RIGHT RIGHT' RESERVED \/ MASJID 9 -BAKR ACTIF Hkll. ABU IC CENTER O W SitINGTON Tht *I / FA2\2°"°.m2 MASJ q : U-BAKR RELY - ....1 I — r ____ _ I \ --a cD N EAST ELEVATION SCALE 1/8"=1' -0" (Th \ORTH ELEVATION 2 SCALE 1/8"= 1' -0" C WEST ELEVATION 3 SCALE 1/8"= 1' -0" - ) \1.) k tiit l `" 8" HEIGHT LL I I ERINGS TYP. cc _ Nt Vi 0 ii-uk CODE CO /to MPLIA A PPROVED NCE DEC 2 6 2008 City Of NO. PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 PERMIT SET NW ARCHITECTURE ARCH I T EC T UR E 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6 . 3 5 5 . 9 6 8 6 REGISTRATION 8171 REGISTERE ARCHITE U KIM STATE OF WASHINGTON NWA PROJECT NO. DRAWN BY DATE SCALE TITLE NUMBER REVISION RECE WED SEP, 1 9 2006 PERMIT CENTER ELEV. 9/1 AS NOTED A3.1 DATE 301-305 CHK BY YK ,-.11 COPY RIGHT RIGHT' RESERVED ROOM SQFT. LPA (W/SF) MAX. WATTS PRAY/WORSHIP 3,801 1.2 4,561.20 MULTI/W. PRAY 1,763 1.2 2,115.60 COMM. SVC. (15) 1,840 1.2 2,208.00 TOTAL STUDY (20) 1,273 1.2 1,527.60 TOTAL 0 EC. 1,342 1.0 1,342.00 TOTAL STORAGE 50 0.5 25.00 KITCHEN 260 1.3 338.00 SUPPLY 95 1.0 95.00 TOTAL ENT. 274 1.2 328.80 BOILER/ELEC. 173 1.4 242.20 TOTAL HALLWAYS 1,311 0.8 1,048.80 TOTAL BATH 596 0.8 476.80 F./M. WASH 484 0.8 387.20 SUBTOTAL 13,262 14,396.20 ;15:I=VZICS:MS.:S= _ g tIF=C=:S:S:S=S=5:=VEY EXIST. EMERGENCY LTG. V.I.F. EXIST. EMERGENCY LTG. V.I.F. SCALE '-0" 12J REFLECTED CEILING PLA\ Ti rtit= 7=7=777 - 77 - 1 0=0 1 1 111111 EXIST. BATHROOM LIGHT FIXTURES TO REMAIN WITHOUT CHANGE 0 EXIST. EMERGENCY it LTG. V.I.F. on EXIST. BATHROOM LIGHT FIXTURES TO EXIST. EMERGENCY REMAIN WITHOUT CHANGE LTG. V.I.F. Eigg 0 EXIST. LIGHT FIXTURES AT FRONT PORCH TO REMAIN WITHOUT CHANGE 1 / 0 f) aR.qaNcY p.xir 1-.C.. TYR 1 i / / / / / rh / / / 0 / L EXIST. EMERGENCY LTG. V.I.F., ry P - 1 • EXIST. n EMERGENCY I-ILTG, V I F . . . NEW CONSTRUCTION LIGHTING BUDGET SUMMARY (MAX. ALLOWED) OCCUPA LIGHTING SUMMARY FLUORESCENT: (2)32 WATTS x 150 EA = 9,600 WATTS PROV'D EMERGENCY LIGHTING CALC. (0.1 WATT/SF) 13,261 SF x 0.1 = 1,326 WATTS REQ'D 60 WATTS x 29 = 1,740 WATTS PROV'D 10/21/08 CLG NOTE 1. ALL MECHIPLUM./ELEC/FIRE PERMITS TO BE DEFERRED PERMITS 2. LIGHTING FIXTURES W/ SHATTERPROOF LIGHT SHIELDING USED IN KITCHEN 3. LIGHTING FIXTURE TO BE AT MINIMUM OF 9'-O HEIGHT FROM A.F.F 4. EXIST. CLG TO REMAIN WITHOUT CHANGE, TYP. 5. RELOCATE LIGHTING FIXTURES PER NEW LAYOUT, TYP. 6. CONTRACTOR TO VERIFY THE REQ'D EMERGENCY LIGHT ILLUMINATION LEVEL., TYP. (1 FC/SF OR 0.1 WATTS/SF) CEILING HEIGHT A.F.F. GWB CEILING 2x4 FLUORESCENT LIGHTS- (2) 32 WATTS EACH 0 TRACK LIGHTS bos-.431 FAN/LIGHTS EMERGENCY CIRCUIT (2) 32 WATTS i l ricvlt....vvi.A., run CODE COMPLIANCE APPROVED DEC 2 6 200d Oty Of Tukwila BUILD ING_DIVISION RCENT' � 2 9 AO PERMIT Cart L: EMERGENCY LIGHTING WALL-HUNG INCANDESCENT: 15 WATTS C) INCANDESCENT - 15 WATTS (RECESSED OR PENDENTED) OM EXIT LIGHT 0 SMOKE DETECTOR NO. REVIEW COMMENTS REVISION 10/21/08 DATE PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKVVILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 PERMIT SET NW ARCHITECTURE ARCHITECTURE 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6 . 3 5 5 . 9 6 8 6 REGISTRATION ONE WAY SWITCH TWO WAY SWITCH 8 17 REGISTERED aU N G f Y 70 22, TATE OF WASHINGTON AR HI. CT NWA PROJECT NO. uJ (f) DRAWN BY DATE SCALE TITLE NUMBER 301-305 CHK BY YK 9/18/2008 AS NOTED REFLECTED CLG. PLAN A4.1 COPY RIGHT RICHT R R` PLANT LIST Botanical Name Common Name Size & Remarks Quantity Acer rubrum 'Pacific Sunset' Pacific Sunset Maple 2" C., street tree* 12 Pyrus calleryana 'Red Spire' Red Spire Pear 2" C., street tree* 12 *matched form, meet minimum ANSI standards Berberis thunbergii 'Crimson Pygmy' Crimson Pygmy Barberry 1 gal. 70 Erica carnea 'Springwood White' Springwood White Heather 1 gal. 86 Helictrotrichon sempervirens Blue Oat Grass 1 gal. 55 Ilex x 'Mondo' Little Rascal Holly 3 gal. 48 Pmnus I. 'Otto Luyken' Otto Luyken Laurel 5 gal. 59 Spiraea bumalda 'Goldflame' Goldflame Spirea 5 gal. 17 PROJECT B 14,360 SF 6-Springwood White Heather I - Redspire Pear 4- Little Rasca holly No Work in Existing Landscape Bed - Seed disturbed areas 9- Goldflame Spirea 4- Redspire Pear 16- Little Rascal Holly 32- Springwood White Heather 4- Little Raseal .Holly 'I [ edspire Pear 6- Springwood White Heather ' t .r. � � , Oy '' m +� �, r� rr vin ,i �iGi4,21 •rv'�q .i� a .,t` . n iii bili��i r rF h� 1 J 2 I - Spnngwood White heather 4 Goldflame Spirea 1 2-Little Rascal Holly 3- Redspire Pear 2)-Springwood 1 White Heather`, 3- Redspire Pear 12- Little`\ Holly EXIST. BLDG. (PAWN )(- CHANGE) 4,008 SF Lou o�d � �II/dI ,/1.L:-�,/.�.�,� ®��" .ate+; �� lCi>�[p»; � s[Gl[t� C�tCll[C1i( ©r+, � \\ t(O rlltgf• � . 86.00' 23- Crimson Pygmy Barberry 5.00` N87° 11 08 "W EXIST. LANDSCAPE TO REMAIN W/O CHANGE ME MMMMM N 8 7 ° 11'06" W No Work in Existing Landscape Bed N 87 ° 11'06" W FENCE No Work in Existing Landscape Bed Limit. of Work 0 47- Crimson Pygmy Barberry 3 1 Blue Oat Grass 38 -Otto Luyken Laurel 7- Pacific Sunset Maple I I EXIS 9 ". BUS SHELTER L RIVE WAY Limit of Work MMMMM WM MI INN MI LANDSCAPE NOTES: I . Refer to details and irrigation plan for additional information. 2. Refer to architectural and civil plans for additional information. 3. No work in existing landscape beds. 4.Distribute 6" depth imported topsoil mix in all landscape areas and at depths indicated for crowing and berming of areas per landscape details. Topsoil mix shall be composed of 2/3 sandy loam and 1/3 compost (Groco or equal as available from Sawdust Supply Co., Seattle, WA (206) 622 -432 I or Great Western Supply, Olympia, WA (360) 754 - 3722.) 5. All new landscape areas shall receive topsoil mix, whether indicated on plans or not, so that finish grades of all shrub beds shall be 2" below tops of adjacent curbs and pavement. Structural fill areas: Any landscape areas occurring within structural fill zones shall have structural fill materials excavated to a depth of I 2" below finish grades in shrub areas and replaced with specified topsoil mix. Dispose of excavated material off site. G. Fertilizer tablets for all plants shall be Agriform (20- I 0 -5) 2 I gram or I 0 gram tablets distributed as follows: All trees: 4 -2 I gram tablets; All shrubs (except I gals): 3 -2 I gram tablets; All I gallons: I -2 I gram tablet; All 2 %" and 4" pot ground covers: I - I 0 gram tablet each. Set tablets directly next to rootball. 7.AI1 shrub beds shall receive a 3" depth of "Fine Grind" hem /fir bark mulch as top dressing. 8.All plants shall be guaranteed for one full year from date of project acceptance. All replacements shall be made within 2 I days of receiving written notice from the Owner. Contractor shall not be responsible for plants dying clue to Owner neglect or vandalism. 9. Plant list quantities are shown for reference only. Contractor is responsible for verifying all quantities in list with actual plan call -outs, and installing plantings per the landscape plan. 10. Contractor to meet all local codes $ ordinances. I I . Field adjust planting plan to reflect actual field conditions. 12. The property owner shall be responsible for maintaining all plants in a healthy growing condition for the life of the project. I I I, I I I I i I I PLANTING PIT SHALL BE A MIN. OF TWICE THE ROOTBAL DEPTH 2" @ SHRUB BEDS, FLUSH @ LAWN AREA ASPHALT PAVING SITE KEY PLAN 3" SHRUB PLANTING DETAIL (CONT., B $ B) 8" ROOTBALL MIN WIDTH rT <0 8' PLANTING PIT - SHALL BE A MINIMUM OF TWICE THE KOOTBALL WIDTH. TREE PLANTING DETAIL FINISH GRADE (INCLUDING BED MULCH) CONCRETE CURB OR ADJACENT PAVEMENT PLANTING PI SHALL BE A MINIMUM OF TWICE THE ROOT - BALL DEPTH d MULCH 2" MULCH IN BASIN FERTILIZE AT TIME OF PLANTING. 3" WATER RETENTION BASIN (IN SHRUB AND GROUNDCOVER AREAS ONLY) FERTILIZER TABLETS REMOVE BURLAP FROM TOP 2/3 OF ROOT BALL. BACKFILL SOIL MIX NOTE: REMOVE TREATED OR SYNTHETIC BURLAP COMPLETELY. NTS WATERING BASIN BERM FERTILIZER TABLETS, 2 " -C" DEPTH PEEL BURLAP BACK FROM TOP HALF OF ROOT BALL AFTER PLACING SHRUB IN PLANTING HOLE (REMOVE COMPLETELY IF FIBERGLASS OR TREATED). BACKFILL SOIL MIX NOTE: GENERAL CONTRACTOR SHALL SAWCUT AND REMOVE EXCESS ASPHALT PAVEMENT AND SUBBASE MATERIAL DOWN TO NATIVE SOIL. PARKING ISLAND PLANTER DETAIL NTS TREE TIES. AREA FOR SPACING ADJUSTMENT THREE 2X2 WOOD STAKES ARRANGED IN TRIANGULAR SPACING AROUND TREE. LIMITS OF TREE PIT WIDTH VARIES REFER TO PLAN 1 UHh1 ; f� - 3" MIN.; REFER TO PLAN FOR SPECIFIC BERM $ CROWN HTS. SUB -BASE MATERIAL NATIVE SOIL TOPSOIL FILL - REFER TO SPECIFICATIONS FOR SOIL TYPE A Revision to parking lot layout at Southwest corner. No landscape. plan revisions. ThIS PLAN IS A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OR PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. TRIANGULAR SPACING WITHIN PLANTING BED SPECIFIED PLANT SPACING = "X" INDIVIDUAL PLANTS REPRESENTED AS: PLANT SPACING DETAIL NTS TREE STAKING DETAIL CONTINUOUS OUTER ROW OF PLANTS SPACED "X" ON CENTER AND SET BACK FROM THE PLANTING BED EDGE 2/3 "X" 2/3 "X" EDGE OF PLANTING BED 2/3 "X" -I- NORTH NTS tita elk etwirogair:41 - litraiont NOTE: INSTALL TREE STAKES ONLY AS NEEDED. IMPORTANT. REMOVE TREE STAKES AFTER ONE YEAR. r CVJIVU � rg\ C ODE C©MPLIA APPROVE DES; 2 6 20G3 QtY Of f-- ►k iila BUILDING DIVISION for Permit 0 I 0' 20' 40' GO' SCALE: I " = 20' -0" sIMMININIMM MIN. DEPTH INTO UNDISTURBED SUBGRADE NTS RECD IVE OCT ,2 9 2008 PERMIT CENTEF G" DEPTH TOPSOIL placed in planting beds .. ;: ,, CONCRETE see civil plans for more information - - -- SLEEVE LOCATION ---- 4" Typical unless otherwise specified PROJECT B 14,360 SF 6-Springwood White Heather I - Redspire Pear 4- Little Rasca holly No Work in Existing Landscape Bed - Seed disturbed areas 9- Goldflame Spirea 4- Redspire Pear 16- Little Rascal Holly 32- Springwood White Heather 4- Little Raseal .Holly 'I [ edspire Pear 6- Springwood White Heather ' t .r. � � , Oy '' m +� �, r� rr vin ,i �iGi4,21 •rv'�q .i� a .,t` . n iii bili��i r rF h� 1 J 2 I - Spnngwood White heather 4 Goldflame Spirea 1 2-Little Rascal Holly 3- Redspire Pear 2)-Springwood 1 White Heather`, 3- Redspire Pear 12- Little`\ Holly EXIST. BLDG. (PAWN )(- CHANGE) 4,008 SF Lou o�d � �II/dI ,/1.L:-�,/.�.�,� ®��" .ate+; �� lCi>�[p»; � s[Gl[t� C�tCll[C1i( ©r+, � \\ t(O rlltgf• � . 86.00' 23- Crimson Pygmy Barberry 5.00` N87° 11 08 "W EXIST. LANDSCAPE TO REMAIN W/O CHANGE ME MMMMM N 8 7 ° 11'06" W No Work in Existing Landscape Bed N 87 ° 11'06" W FENCE No Work in Existing Landscape Bed Limit. of Work 0 47- Crimson Pygmy Barberry 3 1 Blue Oat Grass 38 -Otto Luyken Laurel 7- Pacific Sunset Maple I I EXIS 9 ". BUS SHELTER L RIVE WAY Limit of Work MMMMM WM MI INN MI LANDSCAPE NOTES: I . Refer to details and irrigation plan for additional information. 2. Refer to architectural and civil plans for additional information. 3. No work in existing landscape beds. 4.Distribute 6" depth imported topsoil mix in all landscape areas and at depths indicated for crowing and berming of areas per landscape details. Topsoil mix shall be composed of 2/3 sandy loam and 1/3 compost (Groco or equal as available from Sawdust Supply Co., Seattle, WA (206) 622 -432 I or Great Western Supply, Olympia, WA (360) 754 - 3722.) 5. All new landscape areas shall receive topsoil mix, whether indicated on plans or not, so that finish grades of all shrub beds shall be 2" below tops of adjacent curbs and pavement. Structural fill areas: Any landscape areas occurring within structural fill zones shall have structural fill materials excavated to a depth of I 2" below finish grades in shrub areas and replaced with specified topsoil mix. Dispose of excavated material off site. G. Fertilizer tablets for all plants shall be Agriform (20- I 0 -5) 2 I gram or I 0 gram tablets distributed as follows: All trees: 4 -2 I gram tablets; All shrubs (except I gals): 3 -2 I gram tablets; All I gallons: I -2 I gram tablet; All 2 %" and 4" pot ground covers: I - I 0 gram tablet each. Set tablets directly next to rootball. 7.AI1 shrub beds shall receive a 3" depth of "Fine Grind" hem /fir bark mulch as top dressing. 8.All plants shall be guaranteed for one full year from date of project acceptance. All replacements shall be made within 2 I days of receiving written notice from the Owner. Contractor shall not be responsible for plants dying clue to Owner neglect or vandalism. 9. Plant list quantities are shown for reference only. Contractor is responsible for verifying all quantities in list with actual plan call -outs, and installing plantings per the landscape plan. 10. Contractor to meet all local codes $ ordinances. I I . Field adjust planting plan to reflect actual field conditions. 12. The property owner shall be responsible for maintaining all plants in a healthy growing condition for the life of the project. I I I, I I I I i I I PLANTING PIT SHALL BE A MIN. OF TWICE THE ROOTBAL DEPTH 2" @ SHRUB BEDS, FLUSH @ LAWN AREA ASPHALT PAVING SITE KEY PLAN 3" SHRUB PLANTING DETAIL (CONT., B $ B) 8" ROOTBALL MIN WIDTH rT <0 8' PLANTING PIT - SHALL BE A MINIMUM OF TWICE THE KOOTBALL WIDTH. TREE PLANTING DETAIL FINISH GRADE (INCLUDING BED MULCH) CONCRETE CURB OR ADJACENT PAVEMENT PLANTING PI SHALL BE A MINIMUM OF TWICE THE ROOT - BALL DEPTH d MULCH 2" MULCH IN BASIN FERTILIZE AT TIME OF PLANTING. 3" WATER RETENTION BASIN (IN SHRUB AND GROUNDCOVER AREAS ONLY) FERTILIZER TABLETS REMOVE BURLAP FROM TOP 2/3 OF ROOT BALL. BACKFILL SOIL MIX NOTE: REMOVE TREATED OR SYNTHETIC BURLAP COMPLETELY. NTS WATERING BASIN BERM FERTILIZER TABLETS, 2 " -C" DEPTH PEEL BURLAP BACK FROM TOP HALF OF ROOT BALL AFTER PLACING SHRUB IN PLANTING HOLE (REMOVE COMPLETELY IF FIBERGLASS OR TREATED). BACKFILL SOIL MIX NOTE: GENERAL CONTRACTOR SHALL SAWCUT AND REMOVE EXCESS ASPHALT PAVEMENT AND SUBBASE MATERIAL DOWN TO NATIVE SOIL. PARKING ISLAND PLANTER DETAIL NTS TREE TIES. AREA FOR SPACING ADJUSTMENT THREE 2X2 WOOD STAKES ARRANGED IN TRIANGULAR SPACING AROUND TREE. LIMITS OF TREE PIT WIDTH VARIES REFER TO PLAN 1 UHh1 ; f� - 3" MIN.; REFER TO PLAN FOR SPECIFIC BERM $ CROWN HTS. SUB -BASE MATERIAL NATIVE SOIL TOPSOIL FILL - REFER TO SPECIFICATIONS FOR SOIL TYPE A Revision to parking lot layout at Southwest corner. No landscape. plan revisions. ThIS PLAN IS A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OR PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. TRIANGULAR SPACING WITHIN PLANTING BED SPECIFIED PLANT SPACING = "X" INDIVIDUAL PLANTS REPRESENTED AS: PLANT SPACING DETAIL NTS TREE STAKING DETAIL CONTINUOUS OUTER ROW OF PLANTS SPACED "X" ON CENTER AND SET BACK FROM THE PLANTING BED EDGE 2/3 "X" 2/3 "X" EDGE OF PLANTING BED 2/3 "X" -I- NORTH NTS tita elk etwirogair:41 - litraiont NOTE: INSTALL TREE STAKES ONLY AS NEEDED. IMPORTANT. REMOVE TREE STAKES AFTER ONE YEAR. r CVJIVU � rg\ C ODE C©MPLIA APPROVE DES; 2 6 20G3 QtY Of f-- ►k iila BUILDING DIVISION for Permit 0 I 0' 20' 40' GO' SCALE: I " = 20' -0" sIMMININIMM MIN. DEPTH INTO UNDISTURBED SUBGRADE NTS RECD IVE OCT ,2 9 2008 PERMIT CENTEF 1 G" DEPTH TOPSOIL placed in planting beds :, 4' CONCRL I E see civil plans for more information - - -- SLEEVE LOCATION 4" Typical unless otherwise specified 1 13.33 1" 2 30.29 1 1/2" 3 15.19 1" P.O.C. @ I" Irrigation meter (installed by city.) System Designed for static pressure @ 65 p.s.i. Contractor' to verify location static pressure. Rainbird ESP -MC controller. Contractor to provide I I 0 power conduit to landscape. Field verify location with owner. No Work in Existing Landscape Bed PROJECT BL 14,360 SF This Plan is diagramatic. All mainline and irrigation equipment to remain inside property line and to be placed in shrub beds where possible. 4" Sleeve No Work in Existing Landscape Bed- Seed disturbed areas 4" typ. Property Line 19 This Plan is diagramatic. All mainline and irrigation equipment to remain inside property line and to be placed in shrub beds where possible. 3 tyr. This Plan is diagramatic. All mainline andv irrigat equipment to remain inside property line and to be placed in shrub beds where possible. Limit of Work EXIST. BLDG. (PAVVN X- CHANGE) 4,908 SF Limit of Work 86.00' 4"typ• 4" Sleeve �w i�►� ��,�Zir DRIVE ti LANDSCAPE GARAGE Limit of Work 5.00' N87° 11'08 "V\ / Limit Of-Work EXIST. LANDSCAPE TO REMAIN VV /O CHANGE ■ N 87 ° 11'06 6 W No Work in Existing Landscape Bed I N 87 °11'06" W FENCE No Work in Existing Landscape Bed \ Limit of Work 50 ;T. BUS SHELTER ER 1 1 1 f 1 I I I I II I i i I VE WAY I IRRIGATION LEGEND IRRIGATION SHEET NOTES: I . This plan is diagrammatic; all piping, valves, etc. shall be installed in shrub beds where possible and shall follow the plan as close as is practical. 2. Refer to civil plans for location of I" irrigation meter, installed by city. 3. Refer to irrigation details for additional information. 4. No irrigation to be installed in "existing landscape beds." 5. Verify controller location with general contractor. General contractor to provide power to the controller and provide conduit from the controller to the landscape. G. Locate all mainlines within the project limits and in shrub beds where possible. 7. Landscape contractor to coordinate and install sleeving with general contractor. 8. All manual, gate and electrical valves and other underground equipment shall be housed in Nelson, Ametek or equal rectangular valve boxes. 9. All pipe shall have a firm uniform bearing for the entire length of each line, free of rocks or debris. All trenches containing pipe and /or wires shall be backfilled with clean topsoil, free of all lumber, rubbish and rocks over I " in size, or clean sand if clean topsoil is not available. 10. Contractor shall supply and install all equipment shown on the plans and indicated in the specifications to achieve proper operation of said equipment. All equipment installations, electrical and plumbing connections shall be in conformance with all applicable codes and ordinances, these specifications, and the manufacturers recommendations whether indicated on the drawing or not. I I . Contractor shall guarantee in writing on his company letterhead all materials and workmanship for a period of one full year following acceptance of system installation. 12. Backflow preventer shall be inspected and tested by a certified backflow device inspector. Provide Owner with one copy of approval certificate. 13. Any irrigation lines placed within tree protection zones or existing landscape areas established for the project must be installed in such a manner as to not cause damage to the root protection zone, such as by cutting roots, digging trenches, operation of machinery, etc. Special care must be taken (hand digging trenches, designing lines to stay out of these areas where possible, etc.) to ensure damage to the trees does not occur. SITE BEY PLAN VALVE CHART VALVE GPM SIZE A Revision to parking lot layout at Southwest corner. No Irrigation plan revisions. THIS PLAN IS A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OK PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. /t-- COMPLIANCE ��•L+ AP PROVED BP 26nf) City Of ukvvila I.JJNG DIVISI / 0 10' 20' bO6LI ?:ct for Permit N OKTI 40' SCALE: I " = 20' -0" RECEIVE:17 OCT 2 9 2000 PERMIT CENTEI GO' <-<<1 SYMBOL MFR. CATALOG NO. DESCRIPTION DTL. RAINBIRD 1806 - PRS -15SST 15 STRIP SERIES, SHRUB 6" POP -UP 1806- PRS -I5EST N FEBCO 805Y 1 1/2" DOUBLE CHECK VALVE BACKFLOW PREVENTOR 0 RAINBIRD XBV BRASS BALL VALVE (MATCH LINE SIZE) ® RAINBIRD 3RC QUICK COUPLER VALVE 1 - - ANGLE VALVE FOR MANUAL DRAIN O RAINBIRD PESB 1 1/2" ELECTRIC REMOTE CONTROL VALVE 0 RAINBIRD PESB 1" ELECTRIC REMOTE CONTROL VALVE c RAINBIRD ESP -MC 8 STATION ELECTRO -MECH CONTROLLER NOT SHOWN - - SECURITY CONTROLLER ENCLOSURE 4- --- -- -4 PRESSURE MAINLINE, SCH. 40 PVC PIPE, INSTALL © 18" DEPTH (24" UNDER PAVED AREAS) AREAS) , 5 LATERAL LINES, CLASS 200 PVC PIPE, INSTALL © 12" DEPTH (24" UNDER PAVED 5 CLASS 200 PVC PIPE SLEEVES, INSTALL © 24" DEPTH NOT SHOWN #14 -AWG DIRECT BURIAL LOW VOLTAGE WIRE. RFD= SIGNAI WHITR =mNAKAnml P.O.C. @ I" Irrigation meter (installed by city.) System Designed for static pressure @ 65 p.s.i. Contractor' to verify location static pressure. Rainbird ESP -MC controller. Contractor to provide I I 0 power conduit to landscape. Field verify location with owner. No Work in Existing Landscape Bed PROJECT BL 14,360 SF This Plan is diagramatic. All mainline and irrigation equipment to remain inside property line and to be placed in shrub beds where possible. 4" Sleeve No Work in Existing Landscape Bed- Seed disturbed areas 4" typ. Property Line 19 This Plan is diagramatic. All mainline and irrigation equipment to remain inside property line and to be placed in shrub beds where possible. 3 tyr. This Plan is diagramatic. All mainline andv irrigat equipment to remain inside property line and to be placed in shrub beds where possible. Limit of Work EXIST. BLDG. (PAVVN X- CHANGE) 4,908 SF Limit of Work 86.00' 4"typ• 4" Sleeve �w i�►� ��,�Zir DRIVE ti LANDSCAPE GARAGE Limit of Work 5.00' N87° 11'08 "V\ / Limit Of-Work EXIST. LANDSCAPE TO REMAIN VV /O CHANGE ■ N 87 ° 11'06 6 W No Work in Existing Landscape Bed I N 87 °11'06" W FENCE No Work in Existing Landscape Bed \ Limit of Work 50 ;T. BUS SHELTER ER 1 1 1 f 1 I I I I II I i i I VE WAY I IRRIGATION LEGEND IRRIGATION SHEET NOTES: I . This plan is diagrammatic; all piping, valves, etc. shall be installed in shrub beds where possible and shall follow the plan as close as is practical. 2. Refer to civil plans for location of I" irrigation meter, installed by city. 3. Refer to irrigation details for additional information. 4. No irrigation to be installed in "existing landscape beds." 5. Verify controller location with general contractor. General contractor to provide power to the controller and provide conduit from the controller to the landscape. G. Locate all mainlines within the project limits and in shrub beds where possible. 7. Landscape contractor to coordinate and install sleeving with general contractor. 8. All manual, gate and electrical valves and other underground equipment shall be housed in Nelson, Ametek or equal rectangular valve boxes. 9. All pipe shall have a firm uniform bearing for the entire length of each line, free of rocks or debris. All trenches containing pipe and /or wires shall be backfilled with clean topsoil, free of all lumber, rubbish and rocks over I " in size, or clean sand if clean topsoil is not available. 10. Contractor shall supply and install all equipment shown on the plans and indicated in the specifications to achieve proper operation of said equipment. All equipment installations, electrical and plumbing connections shall be in conformance with all applicable codes and ordinances, these specifications, and the manufacturers recommendations whether indicated on the drawing or not. I I . Contractor shall guarantee in writing on his company letterhead all materials and workmanship for a period of one full year following acceptance of system installation. 12. Backflow preventer shall be inspected and tested by a certified backflow device inspector. Provide Owner with one copy of approval certificate. 13. Any irrigation lines placed within tree protection zones or existing landscape areas established for the project must be installed in such a manner as to not cause damage to the root protection zone, such as by cutting roots, digging trenches, operation of machinery, etc. Special care must be taken (hand digging trenches, designing lines to stay out of these areas where possible, etc.) to ensure damage to the trees does not occur. SITE BEY PLAN VALVE CHART VALVE GPM SIZE A Revision to parking lot layout at Southwest corner. No Irrigation plan revisions. THIS PLAN IS A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OK PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. /t-- COMPLIANCE ��•L+ AP PROVED BP 26nf) City Of ukvvila I.JJNG DIVISI / 0 10' 20' bO6LI ?:ct for Permit N OKTI 40' SCALE: I " = 20' -0" RECEIVE:17 OCT 2 9 2000 PERMIT CENTEI GO' <-<<1 IRRIGATION LEGEND SYMBOL MFR. CATALOG NO. DESCRIPTION DTL. 5ET VALVE BOX FLUSH W/ SURROUNDING FINISHED GRADE G" DIA. CLASS 200 SLEEVE (LENGTH AS REQ'D.) CUT OPENING IN SIDE TO ACCOMODATE NIPPLE FROM MAINLINE (MIN. I" GAP) ( II) MANUAL DRAIN VALVE I "X4" SCH. 80 NIPPLE ±3 CF DRAIN ROCK SUMP NOTES: I . CENTER VALVE BOX OVER VALVE TO FACILITATE REMOVAL AND SERVICING, 2. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 3. AVOID OVER COMPACTING SOIL AROUND VALVE BOXES TO PREVENT COLLAPSE AND DEFORMATION OF VALVE BOXES. I 1 1:1 1 s ' o� >I►'�'i c�iOGo ©DO I ( I —/ I � Oa0oOo0o0o0oC3DOoUD I I I — �oD ©�OUG000U�0000Ont� �I � DO �O OpDO U DO Q o O v oO�O v oG`L= I I :I i 1 = °D� .Le 0 ° o �0 ( 54) ( 530 ( T - Ili. Qo 000 0000©O©O oo0 o ° � ° ©° c � ° o ° � `� ° o ° ©° o ° =III = i 0 -?, o� 2c 0- 0-d Gd o � o� Gsl 111 1='oo © o Q 0- p o 6nr):1 1 111 I IOOo0o0 © o0oO�0o0o0°00 I� 0- o Q © °o ° G0 °o fl °� 1 I; I=OgODGoO oO� Go(-I I I — - ? °� C) CE O O ° rIII i � o��pOp o 1 I =1 ;: 4 .Q a ' II MANUAL DRAIN VALVE 12" NTS VALVE BOXES (TYPICAL) 12" 1419 I "XC" SCH. 80 NIPPLE MAINLINE * TEE WELL COMPACTED SUBGRADE 12" 1419 VALVE BOX INSTALLATION N LATERALA // LINE PIPING 1324 I, NTS /� /���/ KW \\' TRENCH BACKFILL \/, TRENCH DETAIL EDGE OF PAVING OR GRAVEL AREA FINISH GRADE PER SPECIFICATIONS TRACE WIRE TAPED TO TOP OF ALL LATERALS AND MAINLINE @ I 0' O.C. CONTROL WIRE TAPED TO BOTTOM OF MAINLINE @ I 0' O.C. MAINLINE PIPING EDGE OF PLANTING BED OR LAWN AREA NTS 0 W z z 2 z w 0 PVC SCH. 40 MAINLINE W/ MIPT ADAPTERS VALVE BOX: REFER TO IRRIGATION SHEET NOTES OR SPECIFICATIONS 0 0 ✓ PVC MAINLINE U I 0" DIA. VALVE BOX SET FLUSH W/ GRADE VALVE BOX COVER DOUBLE CHECK VALVE 1 -11 1 - 1 — I ` 11 = =i 11 =11 H :11 i =11 i� - 111 - -11..__1! 1-- 111- - 11 GATE VALVE ® " G C" MIN. CLEARANCE) ® o� Q ' 0 _ 0 0Q BACKFLOW PREVENTOR. PEA GRAVEL (INSTALL MIN. 2 CU. F I . BELOW BACKFLOW PREVENTOR) NOTES: I . ALL WIRE INSTALLATIONS WILL BE IN COMPLIANCE W/ APPLICABLE CODES. 2. TAPE AND BUNDLE WIRE EVERY 15 FEET. 3. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. 4. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. 5. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 (EXCEPT UNIONS $ NIPPLES). C . VALVE BOX SHALL NOT REST ON PIPES - PROVIDE 1" CLEAR AROUND ALL PIPES. SET VALVE BOX FLUSH WI SURROUNDING FINISHED GRADE FINISH GRADE AT LIP OF BOX IN TURF AND PAVED AREAS ( I " BELOW LIP IN ALL OTHER AREAS) — 1111 (I �,{I1) II I 0 • - -. Wei SCH. 80 UNION W/ BRASS INSERT GALV. NIPPLES BOX TO CLEAR PIPE BY I " MIN. (TYP.) SCH. 40 MALE 0" 08',D08')(40 80o0°oOo CONTINUOUS BRICK I — !II —��° -- 1I I I I OR FT LUMBER AROUND BASE ADAPTER AUTOMATIC VALVE (I - 1/2" or larger) NTS e rl = — I I I 2" DEPTH OF PEA GRAVEL 1 —1111 1 (6,nI�- •• -111Ui I !, G "DIA. PVC PIPE - 12 "LONG; )0=11 — _ UTILIZE AMETEK 20" DEEP ?>® t (1 i ROADWAY BOX BOTTOM IF MAINLINE DEPTH IS 24" NTS FINISH GRADE LINE SIZED GATE VALVE WELL COMPACTED SUBGRADE NT5 STANDARD CONTROL VALVE BOX -18" DEPTH 3" IN 0'6 no 0-o 0-G oob eO 60 DQ � G � G� G C�c 8 00- 0 O- #4 REBAR W/ S.S. CLAMPS MAINLINE PIPE JUNCTION BOX SCH. 40 CONDUIT FOR POWER SUPPLY WASHED PEA GRAVEL (3" MIN. DEPTH) 4" SCH. 80 NIPPLE W 0 NOTES: I . VALVE KEY HANDLE TO CLEAR TOE OF BOX BY 2" MINIMUM. 2. THREADED ONE END NIPPLE * SOLVENT JOINT NIPPLES TO BE SCHEDULE 80. 3. SUPPLY LINE TEE, THREADED ONE END NIPPLE * SOLVENT JOINT NIPPLES NOT INCLUDED IN PRE- FABRICATED SWING JOINT KIT. I" PVC NIPPLE - LENGTH AS NECESSARY TO ACCOMODATE 45° ANGLE (SOLVENT JOINT) QUICK COUPLER SCH. 40 90° ELL SCH. 40 MALE ADAPTER MAINLINE W/ TEE SCH. 80 UNION (BOTH SIDES OF VALVE) WELL COMPACTED SUBGRADE FIELD VERIFY LOCATION CONTROLLER DETAIL INSTALL WITH 30 -45° ANGLE BOX TO CLEAR PIPE BY I " MIN. (TYP.) LATERAL CONTINUOUS BRICK OR PT LUMBER AROUND BASE RAINBIRD CONTROLLER SCH. 40 PVC FITTINGS * JUNCTION BOX (If") CONTROL ; COMMUNICATION WIRES TO VALVES *SENSORS (PROVIDE 1 COVER @ BURIED CONDUITS) QUICK COUPLING VALVE SET TOP OF BOX FLUSH W /FINISH GRADE FINISH GRADE —\ II �I1 - II I 0 "0 VALVE BOX NOTES: I . ALL WIRE INSTALLATIONS WILL BE IN COMPLIANCE W/ APPLICABLE CODES. 2. TAPE AND BUNDLE WIRE EVERY 15 FEET. 3. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. 4. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. 5. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 (EXCEPT UNIONS * NIPPLES). C. VALVE BOX SHALL NOT REST ON PIPES - PROVIDE I " CLEAR AROUND ALL PIPES. SET VALVE BOX FLUSH W/ SURROUNDING FINISHED GRAD • 111 E. I lal Ir � 1111 " " ►►•11 I D__ , 1111 -III 1 1I1 II1 w z z Q 2 SCH. 40 MALE ADAPTER I " U.S. THREADED ONE END PVC NIPPLE (MIPT) AS RISER I "'LASCO' OR EQUAL PRE- FABRICATED SWING JOINT (SCHEDULE 80) USE SECOND MALE ADAPTER (FROM SWING JOINT KIT) AND SOLVENT JOINT PVC NIPPLE INTO SOLVENT JOINT SUPPLY LINE OUTLET TEE OR ELL NTS NTS STANDARD CONTROL VALVE BOX- I 8" DEPTH I I 0 0 C ��O 0 O�0 i II_I i I 00 I') n o0 oO— I I I — I I : 06 111 0a - w 0,t ` 0060b00°0(.1=1 (l ! I III N 2 Iil--i -- 1--..17_•7•91•43 �jQ •9‹ AUTOMATIC VALVE (I -1/4" or smaller) NTS 3" NOTE: TOE OF SPRINKLER HEAD SHALL BE FLUSH WITH FINISH GRADE li" 1 I II i . m11 1 1 .II 10.110411=1 .1 - 1 r IN. Y PVC TEE OR ELL POLYETHYLENE SWING PIPE (18" MAX. LENGTH) SCH. 40 MALE ADAPTOR w 0 3" M ARLEX STREET ELL W /MALE BARBED ELBOW OR ADPT. SCH. 40 90° ELL MAINLINE W/ TEE WELL COMPACTED SUBGRADE SPRINKLER SHRUB* LAWN SPRAYS OR ROTORS (PGP, T -BIRD OR SIM.) MARLEX STREET ELL W /MALE BARBED ELBOW OR ADPT. PVC LATERAL SPRINKLER HEADS (SPRAY AND ROTOR) NTS OO8'139 ThI5 PLAN 15 A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OR PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. for Permit NORTH 0 x' xx' xx' xx' SCALE: NTS l i.vi.Vvt L , ODE COMPLIANCE APPROV DEC 2 r 1r City Of l BUILDING D I SION WALK OR CURB R CE V1 -v OCT 29 Mb PERMIT CEN I LLJ H- W CO 11 -- Z J cD co O to O O m 0 0 z lk 2 • 0 CZ << L RAINBIRD 1806 – PRS -15SST 15 STRIP SERIES, SHRUB 6" POP –UP 1806 – PRS - 15EST 4 FEBCO 805Y 1 1/2" DOUBLE CHECK VALVE BACKFLOW PREVENTOR 0 RAINBIRD XBV BRASS BALL VALVE (MATCH LINE SIZE) ® RAINBIRD 3RC QUICK COUPLER VALVE 1 – – ANGLE VALVE FOR MANUAL DRAIN Q RAINBIRD PESB 1 1/2" ELECTRIC REMOTE CONTROL VALVE Q RAINBIRD PESB 1" ELECTRIC REMOTE CONTROL VALVE c RAINBIRD ESP –MC 8 STATION ELECTRO –MECH CONTROLLER NOT SHOWN – – SECURITY CONTROLLER ENCLOSURE 5– PRESSURE MAINLINE, SCH. 40 PVC PIPE, INSTALL © 18" DEPTH (24" UNDER PAVED AREAS) AREAS) — — –i) C, LATERAL LINES, CLASS 200 PVC PIPE, INSTALL © 12" DEPTH (24" UNDER PAVED 5 CLASS 200 PVC PIPE SLEEVES, INSTALL © 24" DEPTH NOT SHOWN #14 –AWG DIRECT BURIAL LOW VOLTAGE WIRE, RED = SIGNAL WHITE = COMMON IRRIGATION LEGEND SYMBOL MFR. CATALOG NO. DESCRIPTION DTL. 5ET VALVE BOX FLUSH W/ SURROUNDING FINISHED GRADE G" DIA. CLASS 200 SLEEVE (LENGTH AS REQ'D.) CUT OPENING IN SIDE TO ACCOMODATE NIPPLE FROM MAINLINE (MIN. I" GAP) ( II) MANUAL DRAIN VALVE I "X4" SCH. 80 NIPPLE ±3 CF DRAIN ROCK SUMP NOTES: I . CENTER VALVE BOX OVER VALVE TO FACILITATE REMOVAL AND SERVICING, 2. SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO EDGE. 3. AVOID OVER COMPACTING SOIL AROUND VALVE BOXES TO PREVENT COLLAPSE AND DEFORMATION OF VALVE BOXES. I 1 1:1 1 s ' o� >I►'�'i c�iOGo ©DO I ( I —/ I � Oa0oOo0o0o0oC3DOoUD I I I — �oD ©�OUG000U�0000Ont� �I � DO �O OpDO U DO Q o O v oO�O v oG`L= I I :I i 1 = °D� .Le 0 ° o �0 ( 54) ( 530 ( T - Ili. Qo 000 0000©O©O oo0 o ° � ° ©° c � ° o ° � `� ° o ° ©° o ° =III = i 0 -?, o� 2c 0- 0-d Gd o � o� Gsl 111 1='oo © o Q 0- p o 6nr):1 1 111 I IOOo0o0 © o0oO�0o0o0°00 I� 0- o Q © °o ° G0 °o fl °� 1 I; I=OgODGoO oO� Go(-I I I — - ? °� C) CE O O ° rIII i � o��pOp o 1 I =1 ;: 4 .Q a ' II MANUAL DRAIN VALVE 12" NTS VALVE BOXES (TYPICAL) 12" 1419 I "XC" SCH. 80 NIPPLE MAINLINE * TEE WELL COMPACTED SUBGRADE 12" 1419 VALVE BOX INSTALLATION N LATERALA // LINE PIPING 1324 I, NTS /� /���/ KW \\' TRENCH BACKFILL \/, TRENCH DETAIL EDGE OF PAVING OR GRAVEL AREA FINISH GRADE PER SPECIFICATIONS TRACE WIRE TAPED TO TOP OF ALL LATERALS AND MAINLINE @ I 0' O.C. CONTROL WIRE TAPED TO BOTTOM OF MAINLINE @ I 0' O.C. MAINLINE PIPING EDGE OF PLANTING BED OR LAWN AREA NTS 0 W z z 2 z w 0 PVC SCH. 40 MAINLINE W/ MIPT ADAPTERS VALVE BOX: REFER TO IRRIGATION SHEET NOTES OR SPECIFICATIONS 0 0 ✓ PVC MAINLINE U I 0" DIA. VALVE BOX SET FLUSH W/ GRADE VALVE BOX COVER DOUBLE CHECK VALVE 1 -11 1 - 1 — I ` 11 = =i 11 =11 H :11 i =11 i� - 111 - -11..__1! 1-- 111- - 11 GATE VALVE ® " G C" MIN. CLEARANCE) ® o� Q ' 0 _ 0 0Q BACKFLOW PREVENTOR. PEA GRAVEL (INSTALL MIN. 2 CU. F I . BELOW BACKFLOW PREVENTOR) NOTES: I . ALL WIRE INSTALLATIONS WILL BE IN COMPLIANCE W/ APPLICABLE CODES. 2. TAPE AND BUNDLE WIRE EVERY 15 FEET. 3. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. 4. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. 5. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 (EXCEPT UNIONS $ NIPPLES). C . VALVE BOX SHALL NOT REST ON PIPES - PROVIDE 1" CLEAR AROUND ALL PIPES. SET VALVE BOX FLUSH WI SURROUNDING FINISHED GRADE FINISH GRADE AT LIP OF BOX IN TURF AND PAVED AREAS ( I " BELOW LIP IN ALL OTHER AREAS) — 1111 (I �,{I1) II I 0 • - -. Wei SCH. 80 UNION W/ BRASS INSERT GALV. NIPPLES BOX TO CLEAR PIPE BY I " MIN. (TYP.) SCH. 40 MALE 0" 08',D08')(40 80o0°oOo CONTINUOUS BRICK I — !II —��° -- 1I I I I OR FT LUMBER AROUND BASE ADAPTER AUTOMATIC VALVE (I - 1/2" or larger) NTS e rl = — I I I 2" DEPTH OF PEA GRAVEL 1 —1111 1 (6,nI�- •• -111Ui I !, G "DIA. PVC PIPE - 12 "LONG; )0=11 — _ UTILIZE AMETEK 20" DEEP ?>® t (1 i ROADWAY BOX BOTTOM IF MAINLINE DEPTH IS 24" NTS FINISH GRADE LINE SIZED GATE VALVE WELL COMPACTED SUBGRADE NT5 STANDARD CONTROL VALVE BOX -18" DEPTH 3" IN 0'6 no 0-o 0-G oob eO 60 DQ � G � G� G C�c 8 00- 0 O- #4 REBAR W/ S.S. CLAMPS MAINLINE PIPE JUNCTION BOX SCH. 40 CONDUIT FOR POWER SUPPLY WASHED PEA GRAVEL (3" MIN. DEPTH) 4" SCH. 80 NIPPLE W 0 NOTES: I . VALVE KEY HANDLE TO CLEAR TOE OF BOX BY 2" MINIMUM. 2. THREADED ONE END NIPPLE * SOLVENT JOINT NIPPLES TO BE SCHEDULE 80. 3. SUPPLY LINE TEE, THREADED ONE END NIPPLE * SOLVENT JOINT NIPPLES NOT INCLUDED IN PRE- FABRICATED SWING JOINT KIT. I" PVC NIPPLE - LENGTH AS NECESSARY TO ACCOMODATE 45° ANGLE (SOLVENT JOINT) QUICK COUPLER SCH. 40 90° ELL SCH. 40 MALE ADAPTER MAINLINE W/ TEE SCH. 80 UNION (BOTH SIDES OF VALVE) WELL COMPACTED SUBGRADE FIELD VERIFY LOCATION CONTROLLER DETAIL INSTALL WITH 30 -45° ANGLE BOX TO CLEAR PIPE BY I " MIN. (TYP.) LATERAL CONTINUOUS BRICK OR PT LUMBER AROUND BASE RAINBIRD CONTROLLER SCH. 40 PVC FITTINGS * JUNCTION BOX (If") CONTROL ; COMMUNICATION WIRES TO VALVES *SENSORS (PROVIDE 1 COVER @ BURIED CONDUITS) QUICK COUPLING VALVE SET TOP OF BOX FLUSH W /FINISH GRADE FINISH GRADE —\ II �I1 - II I 0 "0 VALVE BOX NOTES: I . ALL WIRE INSTALLATIONS WILL BE IN COMPLIANCE W/ APPLICABLE CODES. 2. TAPE AND BUNDLE WIRE EVERY 15 FEET. 3. PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN VALVE BOX. 4. COMPACT SOIL AROUND VALVE BOX TO SAME DENSITY AS UNDISTURBED ADJACENT SOIL. 5. ALL PIPE AND FITTINGS WILL BE SCHEDULE 40 (EXCEPT UNIONS * NIPPLES). C. VALVE BOX SHALL NOT REST ON PIPES - PROVIDE I " CLEAR AROUND ALL PIPES. SET VALVE BOX FLUSH W/ SURROUNDING FINISHED GRAD • 111 E. I lal Ir � 1111 " " ►►•11 I D__ , 1111 -III 1 1I1 II1 w z z Q 2 SCH. 40 MALE ADAPTER I " U.S. THREADED ONE END PVC NIPPLE (MIPT) AS RISER I "'LASCO' OR EQUAL PRE- FABRICATED SWING JOINT (SCHEDULE 80) USE SECOND MALE ADAPTER (FROM SWING JOINT KIT) AND SOLVENT JOINT PVC NIPPLE INTO SOLVENT JOINT SUPPLY LINE OUTLET TEE OR ELL NTS NTS STANDARD CONTROL VALVE BOX- I 8" DEPTH I I 0 0 C ��O 0 O�0 i II_I i I 00 I') n o0 oO— I I I — I I : 06 111 0a - w 0,t ` 0060b00°0(.1=1 (l ! I III N 2 Iil--i -- 1--..17_•7•91•43 �jQ •9‹ AUTOMATIC VALVE (I -1/4" or smaller) NTS 3" NOTE: TOE OF SPRINKLER HEAD SHALL BE FLUSH WITH FINISH GRADE li" 1 I II i . m11 1 1 .II 10.110411=1 .1 - 1 r IN. Y PVC TEE OR ELL POLYETHYLENE SWING PIPE (18" MAX. LENGTH) SCH. 40 MALE ADAPTOR w 0 3" M ARLEX STREET ELL W /MALE BARBED ELBOW OR ADPT. SCH. 40 90° ELL MAINLINE W/ TEE WELL COMPACTED SUBGRADE SPRINKLER SHRUB* LAWN SPRAYS OR ROTORS (PGP, T -BIRD OR SIM.) MARLEX STREET ELL W /MALE BARBED ELBOW OR ADPT. PVC LATERAL SPRINKLER HEADS (SPRAY AND ROTOR) NTS OO8'139 ThI5 PLAN 15 A CONCEPTUAL DRAWING AND DUE TO EXISTING SITE CONDITIONS, FIELD ADJUSTMENTS MAY BE NECESSARY. ALL NATURAL PRODUCTS AND /OR PLANT MATERIAL MAY VARY IN SIZE AND SHAPE. for Permit NORTH 0 x' xx' xx' xx' SCALE: NTS l i.vi.Vvt L , ODE COMPLIANCE APPROV DEC 2 r 1r City Of l BUILDING D I SION WALK OR CURB R CE V1 -v OCT 29 Mb PERMIT CEN I LLJ H- W CO 11 -- Z J cD co O to O O m 0 0 z lk 2 • 0 CZ << L ROOM SOFT. OCCU. W.C. PRAY /WORSHIP 3,830 543 REQ'D (PRINCIPAL ASSEM. AREA) MULTI /W. PRAY 1,763 252 2 COMM. SVC. (15) 1,588 106 2 TOTAL STUDY (20) 1,397 70 3 TOTAL OFC. 1,453 15 7 TOTAL STORAGE 50 1 SUPPLY — — D106 KITCHEN 260 2 5' -0 X 4' —O TOTAL ENT. 274 — W107 BOILER/ELEC. 173 1 TOTAL HALLWAYS 1,309 — TOTAL BATH 596 — D118 F./M. WASH 484 — D119 7' -4 x 7' -0 NO SAFET D120 SUBTOTAL 13,177 990 NO. MALE FEMALE W.C. LAV. W.C. LAV. REQ'D (PRINCIPAL ASSEM. AREA) 4 2 4 2 REQ'D (ED. & ACT. AREA) 1 1 2 1 TOTAL REQ'D 5 3 6 3 TOTAL PROV'D 7 5 6 5 NO. SIZE(W x H) INT D101 3' -0 x 7' -0 YES D102 W102 D103 W103 D104 SAFETY W104 U D105 SAFETY D106 W105 W106 5' -0 X 4' —O SAFETY W107 SAFETY W108 U SAFETY W109 D118 U U SAFETY D119 7' -4 x 7' -0 NO SAFET D120 3'0" x 7' -0 YES VERIF NO. SIZE(W X H) INT W101 4' -0 X 4' -0 YES SAFETY W102 FE W103 SAFETY W104 U SAFETY REGUL) W105 W106 5' -0 X 4' —O SAFETY W107 SAFETY W108 U SAFETY W109 4' -0 X 4' -0 SAFETY W110 4' -0 X 4' -0 \/ SAFETY .- STUDY 8 229 SF CONF. OFC 1 275 SF STUDY 2 144 SF VENT TO OUTSIDE (50 CFM) � n STUDY 1 94 SF STUDY 4 124 SF STUDY 5 188 SF STUDY 6 188 SF D107 D109 COMM. SVC. 1,588 SF OCCU:106 CO STUDY 7 276 SF EXIS . ELEC. MOP SINK D112 HALL 77 SF VENT TO OUTSIDE — (100 CFM EA.) F. WASH 359 SF VENT TO A2.1 111,,„ � ►.. OUTSIDE • i (50 CFM) 5'2-0 I i; \BATN �_.� �r [P 3 Sl STOR, 50 SF DIAPER UTSIDE 100 CFM EXIST. BOILER 62 SF — LILT $1D.E (125 CFM EA.) ilbragomMliftaimilTw6_ UTIL. 15 SF HALL 83 SF '4 TJ VI. WASH PI OFC.— ADMIN. 1 170 SF OFC 4 208 SF 47' -9 1/4 POST SIGN (4 DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 130." 0 FC 91 SF 3/20/09 1 � I FLOOR PLAN AL\ GROSS FL. AREA: 14,310 SF SCALE 1/8"=1' —0" (FRONT EVE: NOT INCLUDED): 1,431 SF 1,7 OCCU:252 799 SF NE Y PRAY AREA 31 -2 3/4" EXIST. CANOPY 1,431 SF 143' -1 1/4" EXIST. ENT. 100 SF D11 DRINK'G FNTN HALL 431 SF D112 115 OFC (AUDIO) 140 SF — POST SIGN ® DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 252." SEPARATE PERMIT REQUIRED FC2: G: c" asa BUIL DIVISION ENT. 82 SF VENT 10 DRINK'G FNTN D11 64 —1 1/4" POST SIGN © • DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUR ED." "MAX. OCCUPANCY LOAD 543." NOTES 1. ALL LUMBERS IN CONTACT WITH CONC. TO BE PRESSURE TREATED. 2. NO STRUCTURAL CHANGES. 3. NO CHANGES AT EXTERIOR. 4. SEPARATE MECH. /ELEC. /FIRE PERMIT TO BE APPLIED. 5. A SEPARATE SPRINKLER PERMIT BY CONTRACTOR TO BE APPLIED AS NECESSARY. 6. SEE FIRE EXIT PLAN (A2.4) FOR EXIT LIGHT INSTALLATIONS. 7. ALL EXIT LIGHTS AND FIRE ALARM SYSTEMS TO BE DONE BY LICENSED CONTRACTOR. 8. ALL DOOR HARDWARES TO BE LEVER TYPE AS REQUIRED, TYP., BALDWIN 5460 OR BEIIER. 9. MIN. 50 CFM AT BATHROOM, TYP. SEE FL. PLAN FOR REQ'D CFM. 10. NO COOKING AT KITCHEN /BREAK RM. 11. EXIST. PLUMBING FIXTURES TO REMAIN WITH NECESSARY REPAIR WORKS. 12. A SEPARATE PLUMBING PERMIT FOR THE NEW WORKS TO BE APPLIED. 13. ALL EXIT DOORS TO HAVE PANIC HARDWARE, TYP. 14. SEE A2.2, A2.2A FOR MORE DETAIL INFO CORR. 145 SF OFC —IMAM 161 SF REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. NEW CONSTRUCTION /OCCUPANCY SUMMARY PLUMBING SUMMARY ('06 IBC TABLE 2902.1) DOOR SCHEDULE WINDOW SCHEDULE IN FIELD O NOTES: 1. DOOR AND WINDOW FRAMES TO BE HOLLOW METAL. 2. DOOR HARDWARES TO BE LEVER TYPE OR DETERMINED BY OWNER 3. PLUMB'G FIXTURES AND HARDWARES, ACCESSARIES TO BE DETERMINED BY OWNER EXIST. CONSTRUCTION GALVANIZED MTL STUDS WHERE IN CONTACT W/ / / / / / / / / / 7/ / /2 / / / / CONC., TYP. 3 1 2 - 13 / 6 9 2 TYP. WALL I SCALE 1 1/2"=1'-0" P.T.D. S.D. r 7 4 / ROOF ASSEMBLY 3/8" DEFLECTION SPACE FIRE STOP SEALANT AT FIRE RATED PARTITIONS., TYP. ACOUSTICAL SEALANT AT SOUND RATED PARTITIONS, TYP. LOCATED AT INNER LAYER OF GWB 5/8" TYPE 'X" GWB ON BOTH SIDES (USE WATER RESISTANT BOARD, AT KITCHEN AND BIN RM.)'` FIRE BLOCKING AT MID OF WALL METAL STUDS © 16" 00: 2' -6" TYP. WASHROO SCALE 3/8 " =1' -0" V EGRESS WIDTH PER OCCU: SERVED (TABLE 1005.1): 0.15 x 130 = 19.5" REQ'D i S.D. (WADO) By S, � --aS Date: 3/''3/ / City Of 1'�kwila BUILDING DIVISION REccmgL CITY OF flimit.A IiAK 3 0 2009 PERMIT CENTER P.T.D. S.D. r FILE COPY Permit No. � J1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: REVISION NO.__ IX/ REVIEWED FOR CODE COMPLIANCE APP OV'ED MAR 3 :t 2009 oir City of Telkwila BUILDING DIVISION CERAMIC TILES AT FLOOR AND WALLS, TYP. S.D.: SOAP DISPENSER P.T.D.: PAPER TOWEL DISPENSER CHANGE BY OWNER BID INFO NO. BID INFO REVIEW COMMENTS REVIEW COMMENTS REVISION 3/20/09 1/26/09 1 12/9/08 10 DATE PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 2 0 6. 3 5 5. 9 6 8 6 CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION • REGISTERED ARCHITECT TATE OF WASHINGT 8171 NWA PROJECT NO. DRAWN BY — w DATE SCALE TITLE NUMBER 301 -305 CHK BY YK 9 /18/20 08 AS NOTED FLOOR PLAN, WALL SEC. WASHROOM ELEV. A2.1 ALL COPY RIGHT RIGHTS RESERVED / \ CHANGE BY OWNER 3/20/09 1/26/09. A BID INFO 1/8/09 BID INFO /\ REVIEW COMMENTS 12/9/08 0 NO. REVIEW COMMENTS 10/21/08 DATE REVISION PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 BEFORE CONSTRUCTION CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION o 1711 REGISTER , ARCHITE _ e !! *f ‘Z - d STA OF WASHINGT' NWA PROJECT NO. 301 -305 I3 HS I DRAWN BY - CHK BY YK DATE 9/18/2008 SCALE AS NOTED TITLE ENLARGED FLOOR PLAN NUMBER A2.2A All COPY RIGHT RIGHTS RESERVED 3N1 HOIVW COI CXe I I . U W J W V) X W 0 Li. (!) „Z/ L L L —,L •-- 0 N p X w LL. LID • Q L :D > O�. a U- 0 L0 La I, O w O � m = Q d � w w m LLJ v N UJ z¢ C.) Q cn O J J Li 0 © L : Q • U O w D Ln > O.� vo L La , 21\ � II/II��I / z :a [L LLLa 101/1 � 10,14 tto- 1 i Gi rrAwardirdwaf ,„ I \ ^ U- C!) LCD - 4 „O-,C t - b 0 1 N) to I CO 0 \� n .�..�..��A.. 0 LO All 00 C t-- ✓ ) (!) C3) „ t / „0—‘1. NEI / L 2 — ,Z „Z — ,9 L 0 OZ 1.0 „t/ L 0L-,LL „t7 /2 - b t` >- 0 H- LL_ (0 N- N 90 LM 90LM >- LL 00 00 IIIIIIIIIIIIIIIIIIII. A/ � )/ „0 — tg „0 — t L „0 — t2 „6 D t ram 0 I I I I I I D I F P I/ / / // / /II /IIII / /�/ /IIII / / / /I/ /I /NIAV�/J %1 .• 0 AAL • i • IIII n �i�lt/lll!►� „ , Z L O w CD CC Q - I- mw w J � m LU (n < W C.) V CD < C!) z O 0 N- 0 IC / ,OL —,6L C!) Lr) N- V r ,V V 170 LM „0-,2 „ CC 0 0 „o -,C „0 -, L „0 - 9 N (.3 00 Lt_ O r) £OLM „6 — ,g 0 „0 -, „O — , „O—, i „0 6 17 ./ . ////IIII O REVIEWED FOR CODE COMPLIANCE APPROVED MAR 31 2009 City of Tukwila BUILDING DIV1S1f Nl I LO LM 0 Li CO 0 N z w X W O LL (!) Cn 0 0) „ - 9 E VtSI' 4 7 , ? A '3; � ` O... 9, o b 0 8 Li 3 3N1 HOIVW CITY MAR 3 0 2009 PERMIT CENTER /\ CHANGE BY OWNER 3/20/09 1/26/09 A BID INFO BID INFO 1/8/09 \ REVIEW COMMENTS 12/9/08 10/21/08 \ REVIEW COMMENTS NO. REVISION DATE PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION '171 REGISTE'ED Al3 IT T l) ∎, I ST OF WASHINF ON NWA PROJECT NO. 301 -305 133HS DRAWN BY - CHK BY YK DATE 9/18/2008 SCALE AS NOTED TITLE DEMO PLAN NUMBER ,A2.3 N,L COPY RIGHT RIGHTS RESERVED O DEMO PLAN Q SCALE 1/8 "4-0" Jul O 3/20/09 J O O gc Lgic g]c 0 O a a LI I I L — DEMO 0 EXIST. CONSTRUCTION EVISI DO8 REVIEWED R CODE COMPLIANCE APPROVED MAR 31 2009 City of Tukwila BUILDING DIVISION a R CITY MAR 3 0 2009 PERMIT CENTER EXIST. EMERGENCY TG. V.I.F. EXIST. EMERGENCY LTG. V.I.F. 5 3/20/09 REFLECTED CEILING PA(\ SCALE 1/8 " =1' -0" EXIST. BATHROOM LIGHT FIXTURES TO REMAIN WITHOUT CHANGE EXIST. EMERGENCY LTG. V.I.F. EXIST. LIGHT FIXTURES AT FRONT PORCH TO REMAIN WITHOUT CHANGE EXIST. BATHROOM LIGHT FIXTURES TO REMAIN WITHOUT CHANGE r — 1 I 1 EMERGENCY LTG, TYP. 1 7 f LT I 0 EXIST. EMERGENCY LTG. V.I.F. 1 I , EXIST. EMERGENCY LTG. V.I.F., TYP. f EXIST. EMERGENCY U LTG. V. I .F. NEW C()NSTRI_iC uuuuriIVI. I JuiviIVINR I 3,830 1,763 1,588 1,397 1,453 50 260 274 173 1,309 596 484 13,177 06 IBC T X. ALLOWED) LPA (W /SF) 1.2 1.2 1.2 1.2 1.0 0,5 1.3 1.0 1.2 1.4 0.8 0.8 0.8 MAX. WATTS 4,561.20 2,115.60 2,208.00 1,527.60 1,342.00 25.00 338.00 95.00 328.80 242.20 1,048.80 476.80 387.20 14,396.20 • it : MULTI /W. PRAY COMM. SVC. (15) TOTAL STUDY (20 TOTAL OFC. TOTAL STORAGE SUPPLY KITCHEN TOTAL ENT. BOILER /ELEC. TOTAL HALLWAYS TOTAL BATH F. /M. WASH SUBTOTAL ET._S-UM PLUMBING SUMMARY (' MALE LIGHTING SUMMARY FLUORESCENT: (2)32 WATTS x 150 EMERGENCY LIGHTING 13,261 SF x 0.1 = 60 WATTS x 29 = 1/8/ EA = 9,600 WATTS PROV'D CALC. (0.1 WATT /SF) 1,326 WATTS REQ'D 1,740 WATTS PROV'D CLG NOTE 1. ALL MECH. /PLUM. /ELEC /FIRE PERMITS TO BE DEFERRED PERMITS 2. LIGHTING FIXTURES W/ SHATTERPROOF LIGHT SHIELDING USED IN KITCHEN 3. LIGHTING FIXTURE TO BE AT MINIMUM OF 9' -0 HEIGHT FROM A.F.F 4. EXIST. CLG TO REMAIN WITHOUT CHANGE, TYP. 5. RELOCATE LIGHTING FIXTURES PER NEW LAYOUT, TYP. 6. CONTRACTOR TO VERIFY THE REQ'D EMERGENCY LIGHT ILLUMINATION LEVEL., TYP. (1 FC /SF OR 0.1 WATTS /SF) '— ' CEILING HEIGHT A.F.F. b b GWB CEILING 2x4 FLUORESCENT LIGHTS — (2) 32 WATTS EACH b TRACK LIGHTS FAN /LIGHTS EMERGENCY CIRCUIT (2) 32 WATTS 1)084-439 REVIEWED FOR CODE COMPLIANCE APPROVED 1 MAR 3 1 2009 City of Tukwila I BUILDING DIVISION GINLA MAR 3 0 2009 PERMIT CENTER coo 0 SD /\ CHANGE BY OWNER BID INFO BID INFO REVIEW COMMENTS REVIEW COMMENTS REVISION NO. EMERGENCY LIGHTING WALL —HUNG INCANDESCENT: 15 WATTS INCANDESCENT — 15 WATTS (RECESSED OR PENDENTED) EXIT LIGHT SMOKE DETECTOR ONE WAY SWITCH TWO WAY SWITCH 3/20/09 1/26/09 1/8/09 12/9/08 10/21/08 DATE PROJECT TITLE /OWNER ABU —BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. NWA PROJECT NO. DRAWN BY — w DATE SCALE TITLE NUMBER 301 -305 CHK BY YK 9/ 18/2008 AS NOTED REFLECTED CLG. PLAN A4.1 ALL COPY RIGHT RIGHTS RESERVED - REQ'D PROV'D ZONING: NCC NCC CONDITIONAL USE PERMIT CONDITIONAL USE PERMIT CONDITIONAL USE PERMIT PARKING (FIG. 18 -7): (PRAY (Sc MULTIL RM) 1/4 SEATS OR 1/100 SF (5,691 SF) 114 PROV'D (107 LOTS + 7 LOTS) BIKE RACK (1/50 PARK'G LOTS): 3 REQ'D 3 PROV'D HEIGHT N/A N/A SETBACK N/A N/A LANDSCAPE YES YES GENERAL NOTES 1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC., AND NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 2. ALL CONSTRUCTION SHALL COMPLY WITH THE SEATTLE 2006 INTERNATIONAL BUILDING CODE, WASHINGTON STATE REGULATIONS FOR BARRIER FREE DESIGN, WASHINGTON STATE ENERGY CODE ('06 IBC), AND ALL APPLICABLE LOCAL CODES, ORDINANCE, AND STANDARDS. 3. ALL ITEMS MARKED "N.I.C." ARE NOT PART OF THIS CONTRACT. 4. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 5. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. CONTRACTOR SHALL CONSULT OWNER'S REPRESENTATIVE WHEN ADDRESSING QUESTIONS OF MATERIALS, METHODS, DETAILS OR WORKMANSHIP NOT COVERED IN THE CONTRACT DOCUMENTS. 6. ALL DIMENSIONS SHOWN ON DRAWINGS ARE TO FACE OF STUD, OR FACE OF FOUNDATION UNLESS OTHERWISE NOTED. 7. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE SAME AS FOR OTHER SIMILAR WORK. 8. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 9. CONTRACTOR SHALL VERIFY ALL "BUILDING STANDARDS" WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHERE SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF WORK. CONTRACTOR SHALL REQUEST VERIFICATION FROM UTILITY COMPANIES OF UNDERGROUND UTILITY LOCATIONS PRIOR TO BEGINNING EXCAVATIONS. 1 1. THE CONTRACTOR SHALL VERIFY AND CONFIRM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. 12. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT SO THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 13. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES. 14. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 15. OWNER SHALL PROVIDE BUILDING PERMIT TO THE CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. 16. CONTRACTOR SHALL SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE, CONSTRUCTION, LABOR, HEALTH AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS FORWARDING PROOF OF SUCH ACTION TO THE OWNER PRIOR TO COMMENCEMENT OF CONSTRUCTION. 17. CONTRACTOR SHALL SECURE AND PROVIDE ALL PERMITS FOR OCCUPANCY, UTILITIES AND ANY OTHERS REQUIRED BY GOVERNING AUTHORITIES BEYOND THE BASIC BUILDING PERMIT, MAKING TIMELY APPLICATIONS AND INQUIRIES, PAYING ALL FEES AND POSTING ALL BONDS TO BE RELEASED AT THE COMPLETION OF CONSTRUCTION. 18. CONTRACTOR SHALL PROVIDE DRAWINGS, SHOP DRAWINGS AND CALCULATION AS REQUIRED FOR OWNER APPROVAL AND PERMITTING OF THE FIRE ALARM DETECTION / MONITORING SYSTEM, HVAC SYSTEM, AND ALL OTHER SYSTEMS REQUIRING BIDDER DESIGN. SUCH REVIEW AND APPROVAL SHALL BE BY THE OWNER. ALLOW A MINIMUM OF TWO WEEKS FOR REVIEW. cI: NOTES SCALE - MIRROR ACCESSIBLE LAVATORY W/ GR INSULATED BOOT OVER PIPES OF LAV. TYP. TOILET ELEVATION SCALE 3/8 " =1' -0" SANITATION CONSTRUCTION ./- MIN. 2' -0" © FRONT & SIDE, TYP. 0 W N z\ 2'- B BAR c. OF WATER CLO�ET 12' LAV TYP. 6" COVE UP, NO RUBBER BASE ALLOWED. WOOD TRIM CO nrso 5A oJ V) MIN. 2'-0" 0 r 19. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA, AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. THESE MODIFICATIONS SHALL BE TRANSFERRED TO A SET OF REPRODUCIBLES AND GIVEN TO THE OWNER PRIOR TO FINAL PAYMENT. 20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETE. 21. ALL WORK SHALL BE GUARANTEED FOR THE PERIOD OF ONE (1) YEAR AFTER COMPLETION UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 22. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE, VIBRATION, HAZARD OR OTHER CAUSES. IN ADDITION, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OR VIBRATION. ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST, DEBRIS, AND CONSTRUCTION MATERIALS AT ALL TIMES. 23. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 25 OF THE '06 I.B.C. 24. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. 25. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE '06 I.B.C. AND THE U.S. PRODUCT SAFETY COMMISSION: SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS (42 CFR 1426; 16 CFR PART 1201) 26. THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURERS. 27. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. 28. ELECTRICAL ROUGH -IN AND REFLECTED CEILING PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED. 29. EXIT SIGNS AND EMERGENCY EXIT ILLUMINATION SHALL CONFORM TO THE '06 I.B.C. CHAPTER 10 AND JURISDICTION FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND EXIT LIGHTNING AS REQUIRED BY THE JURISDICTION FIRE AND BUILDING DEPARTMENTS. CONFIRM ACCEPTABILITY OF LOCATIONS WITH OWNER'S REPRESENTATIVE BEFORE INSTALLATION AND LICENSING. CONTRACTOR SHALL FURTHER POST ALL BONDS 30. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 31. FIRE EXTINGUISHERS: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHALL REQUIREMENTS. CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE EXTINGUISHERS REQUIRED BY NFPA 10 MOST RECENT EDITION AND APPROVED BY FIRE DEPARTMENT. CONFIRM ACCEPTABILITY OF LOCATION WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. 32. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCUPANCY EXCEPT AS PROVIDED IN NFPA STANDARD 30 AND THE CURRENT UNIFORM FIRE CODE. PERMIT MAY BE REQUIRED. 33. ALL DRAPES, HANGINGS, CURTAINS, DROPS, AND ALL OTHER DECORATIVE MATERIALS, THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM NON- FLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTION OR PROCESS APPROVED BY THE FIRE MARSHALL. PROVIDE A CERTIFICATION TO THIS EFFECT. B. EXIT DOORS, EXIT LIGHTS, AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. C. MINIMUM FLAME SPREAD CLASSIFICATION OR INTERIOR FINISHES SHALL BE PER TABLE 803.5 OF '06 I.B.C. et. MIN. 1 " -18 7 M1N. 12" i 6 3q CT) A FRONT - YP. TOILET ELEV. SCALE 3/8 " =1' -0" CO r) rr) 12' ID AX 42" MIN B SIDE 5 39 " -41" U x " MIN FOR PE 1 STD. SHALL / / SEAT COVER DISP. SEPARATE PERMIT REQUI ED FOR: to' ohanical ectricat Pumbing 'as Piping City of Tukwila BUILDING DIVISION PLAN AVATORY DIAGRA SCALE 3/8 " =1' -0" FACE OF WALL 34. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER '06 I.B.C. SECTION 803.9, AND GWB. CEILING SHALL BE INSTALLED PER '06 IBC SECTION. 2504, 2508.5 35. THE LIVE LOADS FOR EACH FLOOR, OR PART THEREOF, WHICH HAVE BEEN DESIGNED FOR A COMMERCIAL OR INDUSTRIAL BUILDING, SHALL BE CONSPICUOUSLY POSTED BY THE OWNER IN THAT PART OF EACH STORY IN WHICH THEY APPLY USING DURABLE METAL SIGNS. IT SHALL BE UNLAWFUL TO REMOVE OR DEFACE SUCH NOTICES. THE OCCUPANT OF THE BUILDING SHALL BE RESPONSIBLE FOR KEEPING THE ACTUAL LOAD BELOW THE ALLOWABLE LIMITS. 36. SOUND INSULATE ALL PLUMBING WALLS AND LINES. 37. ALL GYPSUM WALLBOARD SHALL BE 5/8, TYPE "X" UNLESS NOTED OTHERWISE. 38. TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA COMMUNICATIONS CABLING SYSTEM. CONTRACTOR TO COORDINATE TIMING AND OTHER REQUIREMENTS WITH TENANT. 39. PROVIDE AS -BUILT MODIFICATIONS TO ARCHITECTURAL, MECHANICAL, ELECTRICAL, FIRE AND SMOKE MONITORING DETECTION SYSTEMS ON REPRODUCIBLES SUPPLIED BY THE OWNER. SUCH AS -BUILT DRAWINGS WILL BE COMPLETED, SUBMITTED AND APPROVED BY THE OWNER PRIOR TO TO THE FINAL PAYMENT. 40. PROVIDE BLOCKING IN ALL WALLS TO SUPPORT CABINETRY, SHELVING, BATHROOM FIXTURES, DISPLAY RAILS AND ALL OTHER EQUIPMENT OR IMPROVEMENTS AS REQUIRED. 41. THE CONTRACTOR SHALL CONSULT ALL PLANS AND DRAWINGS OF ALL TRADES FOR OPENINGS THROUGH SLABS, FLOOR SYSTEM, ROOF SYSTEMS, WALLS, CEILING AND CHASES FOR CUTS, PIPES, CONDUITS AND EQUIPMENT; AND SHALL VERIFY SIZE, WEIGHT AND LOCATION WITH RESPECTIVE SUBCONTRACTORS. 42. ALL WORK PERFORMED BY ALL SUBCONTRACTORS SHALL BE IN COMPLIANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 43. PROJECT OWNER AND CONTRACTOR TO VERIFY HAZARDIOUS MATERIALS AS NECESSARY, SUCH AS ASBESTOS, AND HIRE SPECIAL CONSUNTANT AND CONTRACTOR(S) BEFORE PERFORMING REGULAR CONSTRUCTION WORKS. 44. CODES AND REGULATIONS ON "ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES" ARE COMPLIED BY ICC /ANSI A117.1 -2003. IF THERE ARE DISCREPENCIES, NOTIFY ARCHITECT IMMEDIATELY FOR CORRECTIONS. FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field ' ' , y and conditions is a .: owledged: By Data: .04/4/2_ ,7 City ofn,kwna BUILDING DMSION MIRROR TEMPERATURE SHIELDING FRONT ELEVATION REVISIONS No changes snail be mad to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitt I and may include addi ' . I I,n ., c„- WALLS WITHIN 2 F'T: OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 F. ABOVE THE FLOOR. x Q 7 .• r N N N N PROJECT DESCRIPTION CONDITIONAL USE PERMIT FOR: TENANT IMPROVEMENT (T.I.) WORK FROM CASINO (A -3) TO MOSQUE (A-3) PROJECT ADDRESS: 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 MUHAMMAD JALYALAR: 206) 799 -1379 PARCEL TAX NO: 161000 0125 SEC /TOWNSHIP /RANGE: SW 15 23 4 LEGAL DESCRIPTION CLARKS JAMES GARDEN ADD E 5 FT OF LOT 4 TGW ALL LOTS 5 & 6 TGW N 89 FT OF LOT 1 TGW N 100 FT OF LOT 12 - PORTION OF PARCEL A OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO L99 -0072 RECORDING NO 19991007002061 ZONING: NCC LAND USE: COMMERCIAL CODE: '06 IBC OCCUPANCY: A -3 OCCUPANT LOAD: SEE BELOW TYPE OF CONSTRUCTION: V -B, SPRINKLER OCCUPANCY SUMMARY: (SEE FL. PLAN) SEE A2.1 OCCUPANCY SUM. PLUMBING SUM. ('06 IBC TABLE 2902.1): SEE A2.1 OCCUPANCY SUM. LOT SUMMARY: PARKING: 1 PER EVERY 4 FIXED SEATS OR 100 SF OF ASSEMBLY AREA SPRINKLER: EXIST, MODIFY PER NEW WALL LOCATION HVAC SYSTEM (HEATING & COOLING): DEFERRED (A SEPERATE PERMIT BY CONTRACTOR AS REQ'D) MECH (HVAC) /ELEC. /PLUMB. /FIRE ALARM /SPRINKLER PERMITS: DEFERRED (A SEPERATE PERMIT BY CONTRACTOR AS REQ'D) N N N PROJECT INFOR ' J SCALE - N CODE SUMMARY FACE OF WALL 7" MIN ' MA / X A MI SION N0J-___ N TEMPERATURE SHIELDING KICK SPACE SIDE ELEVATION VATIO\ 1 CORRECTION LTR#_ i PROPERTY OWNER ('S REPRESENTATIVE) ABU -BAKR ISLAMIC CENTER 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 T: 206) 799 -1376 PROJECT OWNER ('S REPRESENTITIVE): MUHAMMAD JALYALAR: T: 206) 799 -1379 1954 UNION AVE NE., RENTON, WA 98059 GENERAL CONTRACTOR: TBD ARCHITECT: NW ARCHITECTURE 3828 4TH AVE S. SEATTLE, WA 98134 T: (20• 5 -' a - YOU IM, AIA TABLE OF CONTENTS: A1.1: PROJECT INFO., VICINITY MAP, NOTES, BATHROOM DETAILS A1.2: SITE PLAN A1.3: DETAILS A2.1: FLOOR PLAN, SCHEDULES, NOTES, WALL SEC., WASHROOM ELEV. A2.1F-A: OUTLET PLAN (BID INFO.) A2.1 F -B: FIN. PLAN (BID INFO.) A2.2: ENLARGED PLAN -NORTH A2.2A: ENLARGED PLAN -SOUTH A2.3 DEMO. PLAN A2.4: FIRE EXIT PLAN A2.5: B. RM. PLAN, W. RM. ELEV. (BID INFO.) A3.1: ELEV. (NO CHANGE) A4.1: REFLECTED CLG. PLAN L -1: , LANDSCAPE PLAN L -2: IRRIGATION PLAN L -3: IRRIGATIO DETAILS 5C \OT USED SCALE - S 140TH ST. 0 S 142TH ST. VINCI \I - Y VIAP SCALE N.T.S. GRAB BAR SCALE 3/8 " =1'- `z -I m z S 141TH ST. Q TOILET PAPER DISPENSERS SHALL BE MIN. 7" TO MAX. 9" IN FRONTOF THE TOILET. THE OUTLET OF THE DISPENSER SHALL BE 15" MIN. TO 48" MAX. ABOVE FLOOR. THERE SHALL BE A CLEARANCE OF 1.5" MIN. BELOW AND 12" MIN. ABOVE THE GRAB BAR. OTHER DISPENSERS AND DISPOSAL FIXTURES SHALL BE LOCATED 40" MAX. ABOVE THE FLOOR OR GROUND TO ANY RACK, OPERATING CONTROL, RECEPTACLE OR DISPENSERS. FLOORS, TOILET AND BATH RM. FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 FT. ABOVE THE FLOOR. 6"x14 GA PLATE NOTCHED INTO STUDS 3/8" 0 TOGGLE BOLT » 1/6/ PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1 379 BEJORE CONSTRUCTION CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS CLARIFICATIONS. REGISTRATION NO BID INFO BID INFO REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 0 2009 b`-City bl- City of Tukwila BUILDING DIVISION REVIEW COMMENTS REVIEW COMMENTS REVISION PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 a 1 71 REGISTERE ARCHITECT J� 6 i, i''ou t' /T. , 4 :STAY OF INGTO NWA PROJECT NO DRAWN BY DATE SCALE TITLE NUMBER RECEIVED CITY OF TUKWILA APR 2 2 2009 PERMIT CENTER 9/18/2008 AS NOTED 1/26/09 1/8/09 12/9/08 10/21/08 DATE 301 -305 CHK BY PROJECT INFO., MAP, NOTES, RESTROOM DTLS A1.1 YK ALL COPY RIGHT RIGHTS RESERVED ROOM SQFT. OCCU. W.C. PRAY /WORSHIP 3,830 543 REQ'D (PRINCIPAL ASSEM. AREA) MULTI /W. PRAY 1,763 252 2 COMM. SVC. (15) 1 ,588 106 2 TOTAL STUDY (20) 1,397 70 3 TOTAL OFC. 1,453 15 7 TOTAL STORAGE 50 1 SUPPLY — — D106 KITCHEN 260 2 5' -0 X 4' -0 TOTAL ENT. 274 — W107 BOILER /ELEC. 173 1 TOTAL HALLWAYS 1,309 — TOTAL BATH 596 — D 118 F./M. WASH 484 — W110 D119 7' -4" x 7' -0" NO SAFET SUBTOTAL 13,177 990 YES NO. MALE FEMALE W.C. LAV. W.C. LAV. REQ'D (PRINCIPAL ASSEM. AREA) 4 2 4 2 REQ'D (ED. & ACT. AREA) 1 1 2 1 TOTAL REQ'D 5 3 6 3 TOTAL PROV'D 7 5 6 5 NO. SIZE(W x H) INT D101 3' -0" x 7' —O" YES D102 -- SAFE PT D103 W103 6' -0 X 4' -0 D104 SAFETY W104 4' -0 X 4' -0 D105 SAFETY 4' -0 X 4' -0 D106 W105 RCGULI W106 5' -0 X 4' -0 SAFETY W107 SAFETY W108 \/ SAFETY W109 D 118 V SAFETY W110 D119 7' -4" x 7' -0" NO SAFET e 'e" ' 0 YES VERIF D121 6' -0" x 7' -0" YES TO M, NO. SIZE(W X H) INT W101 4' -0 X 4' -0 YES SAFELY -- SAFE PT W-1-G2 W103 6' -0 X 4' -0 SAFETY W104 4' -0 X 4' -0 SAFETY 4' -0 X 4' -0 W105 RCGULI W106 5' -0 X 4' -0 SAFETY W107 SAFETY W108 \/ SAFETY W109 4' -0 X 4' -0 SAFETY W110 4' -0 X 4' -0 U SAFETY STUDY 3 154 SF STUDY 8 229 SF CONF. OFC 1 275 SF STUDY 2 144 SF OFC 2/3 318 SF OFC 4 208 SF D10 0 D105 FLOOR PLAN SCALE 1/8 " =1' -0" 39' —8 3/4" STUDY 1 94 SF HALL 573 SF STUDY 4 124 SF STUDY 5 188 SF STUDY 6 188 SF VENT TO OUTS! (50 CFM) 47' -9 1/4 N 0 0 D108 I,J DR∎KG� FNTN D107 D109 COMM. SVC. 1,588 SF OCCU:106 O UNISE 53 p 00 0 STUDY 7 276 SF D11, EXIST. ELEC. 111 SF x MOP SINK HALL 77 SF POST SIGN © DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 14." 40' -7 1/4" — VENT TO OUTSIDE — F. WASH 359 SF VENT TO ® OUTSIDE (50 CFM) OFC 91 SF GROSS FL. AREA: 14,310 SF (FRONT EVE: NOT INCLUDED): 1,431 SF (100 CFM EA.) 143'-1 1/4" W. (EXIST.) ° 170 SF FD QQQ \TYP. A2.1 W ENT TO OUTSIDE \ — — 150 '° -V IT`T0 KITCH. (BREAK) ®OUTSIDF,, 260 SF (100 CFM)' MULTI .PRA 1,763 SF OCCU:252 799 SF NE PRAY AREA STOR. 50 SF 31 -2 3/4" EXIST. CANOPY 1,431 SF EXIST. ENT. 100 SF DIAPER D118 EXIST. BOILER 62 SF DRINK'G FNTN HALL 431 7 V / / / / / / / / / / / / / / / / / / / / / OFC (AUDIO) 140 SF IV 40 6114 STOR\ UTIL. 15 SF A. WASH POST SIGN © DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 252." — Si E (125 CFM EA.) HALL 83 SF ®� M. (EXIST. 267 SF FD ENT 82 SF 62' -9 1/4" 1'f - /I( 5'. ® j / 0 VENT TO OUTSIDE 6' -4 3/4 � DRINK'G FNTN NOTES 1. ALL LUMBERS IN CONTACT WITH CONC. TO BE PRESSURE TREATED. 2. NO STRUCTURAL CHANGES. 3. NO CHANGES AT EXTERIOR. 4. SEPARATE MECH. /ELEC. /FIRE PERMIT TO BE APPLIED. 5. A SEPARATE SPRINKLER PERMIT BY CONTRACTOR TO BE APPLIED AS NECESSARY. 6. SEE FIRE EXIT PLAN (A2.4) FOR EXIT LIGHT INSTALLATIONS. 7. ALL EXIT LIGHTS AND FIRE ALARM SYSTEMS TO BE DONE BY LICENSED CONTRACTOR. 8. ALL DOOR HARDWARES TO BE LEVER TYPE AS REQUIRED, TYP., BALDWIN 5460 OR BEI I ER. 9. MIN. 50 CFM AT BATHROOM, TYP. SEE FL. PLAN FOR REQ'D CFM. 10. NO COOKING AT KITCHEN /BREAK RM. 11. EXIST. PLUMBING FIXTURES TO REMAIN WITH NECESSARY REPAIR WORKS. 12. A SEPARATE PLUMBING PERMIT FOR THE NEW WORKS TO BE APPLIED. 13. ALL EXIT DOORS TO HAVE PANIC HARDWARE, TYP. 14. SEE A2.2, A2.2A FOR MORE DETAIL INFO OF FL. PLAN. OFC. —ADMIN 2 190 SF OFC. — ADMIN. 170 SF l � q ( . �`Li 0, �L O / / / P'AY WO SHIP / / 3,830 SF / NET PRAY AREA 64 —1 1/4" POST SIGN © DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUP ED." "MAX. OCCUPANCY LOAD 543." OFC —IMAM 161 SF 0 0 cD od NEW CONSTRUCTION OCCUPANCY SUMMARY PLUMBING SUMMARY ('06 IBC TABLE 2902.1) DOOR SCHEDULE WINDOW SCHEDULE IN FIELD O CU N (ON TCH IN DIMS AND COLOR ETC. 1/8/09 NOTES: 1. DOOR AND WINDOW FRAMES TO BE HOLLOW METAL. 2. DOOR HARDWARES TO BE LEVER TYPE OR DETERMINED BY OWNER 3. PLUMB'G FIXTURES AND HARDWARES, ACCESSARIES TO BE DETERMINED BY OWNER E CONSTRUCTION GALVANIZED MTL STUDS WHERE IN CONTACT W/ // CONC., TYP. TYP. WALL SCALE 1 1/2 " =1'— P.T.D S.D. ROOF ASSEMBLY 3/8" DEFLECTION SPACE FIRE STOP SEALANT AT FIRE RATED PARTITIONS., TYP. ACOUSTICAL SEALANT AT SOUND RATED PARTITIONS, TYP. LOCATED AT INNER LAYER OF GWB 5/8" TYPE 'X" GWB ON BOTH SIDES (USE WATER RESISTANT BOARD AT KITCHEN AND BATH RM.) FIRE BLOCKING AT MID OF WALL METAL STUDS © 16" O.C. TYP. WASHROOM (WADO) SCALE 3/8 " =1' -0" REV' D0f3g-- 439 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 0 2009 City of Tukwila BUILDING DIVISION EGRESS WIDTH PER OCCU. SERVED (TABLE 1005.1): 0.15 x 130 = 19.5" REQ'D RECEIVED CITY OF TUKWILA APR 2 2 MY PERMIT CENTER f P.T.D. S.D. CERAMIC TILES AT FLOOR AND WALLS, TYP. S.D.: SOAP DISPENSER P.T.D.: PAPER TOWEL DISPENSER NO. ADD IN FO. REVISION 03/31 /09 DATE PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION w 8171 41. DRAWN BY DATE SCALE TITLE NUMBER REGISTERE ARCHITEC ATE •F /WA'HINGT N ,Z v NWA PROJECT N6. 301 -305 CHK BY YK 9 AS NOTED FLOOR PLAN, WALL SEC. WASHROOM ELEV. A2.1 ALL COPY RIGHT RIGHTS RESGRVGD EXIST. ENT. 100 SF DIAPER WH EXIST. BOILER 62 SF DRINK'G FNTN E HALL 242 SF A2.5 UNIT VENT TO OUTSIDE (100 CFM) OFC. (ACCOUNT) 85 SF > VENT TO MALE WASHY OUTSIDE 125 SF 50 CFM , FD- -. -0 " FD ( ) i5i 53 SF ��� ' E� EL �, i' 'l4'i TYP. III 0115A EXIST. FLOOR P_AN SCALE 1/4 " =1' -0" UTI L. 15 SF HALL 218 SF VENT TO 'ASH OUTSIDE UNIT (50 CFM) / / / / / / / / / / 0 / / / / / / / / / / / / / / / / / / ENT. 82 SF ACCESSIBLE BATHROOM SIGNAGE, SEE TABLE ON A1.3 DRINK'G FNTN N) SHWR. UNIT S A2.5 DTLS. E EV. OFC. -ADMIN 2 190 SF OFC. -ADMIN 1 170 SF CORRIDOR 145 SF :NIl HOIVW W F ZD O U a z W r A 0 ► U W W F-- cn >< W 0 I x V) LC) „Z/ L L L 0 Lti >o'— LOLa mormems s s ■w= .r s s I' / / V) I/ 0 n b 0 1.0 ,L O IJ 0 J � m = Q Q rr BililiflUINESIMI r MEW ra - W J � w M ( W < < (-) cn o „Z/ L 0 L —,9 © O LLL ..� i► , 0- I. q 1 1 n 0 r21rii..1114.- 0 OZ La „ 9 ,Z „0 -,q „0 „0 -,� LOLM LC) 00 0 F- Cn Cn 00 co «7 /L £ -,ZL ‘ ,17/1. O L —, L L LL Cn o) N N LL V) rn O N „Z -,9 L 0 W 0 rz m .CC Q ~ CO W Pr) CO 0 90IM 1 O a fI 0 /////////// ri 1 /,I' / „ — Ig „0 - I I16 0 r A • i r II / : £ - I 90LM �— Z L 0 W O J m = Q Q m W W W J � m wr2 O � W < CD < cn 0 0 / L - ,6L Li C/) 10 N ,V V MIA o— II 0 0 C) I) N Ca U- 0 C/) 00 Pr) IIO — I` II L — { L I<O - 2 t {O 1. „0 — I 9 £0LM „0L -,ZZ II ,g 101 0 V -,L III C 0 - ( II LC) 0 a f L0LM Cs LL 0 Li CO O N REVISI b 0 8 3 LL Cn a LC) I/ / /I / / /II/ ]Nn �-' HOIVW ol 0 W C) REVIEWED FOR CODE COMPLIANCE APPROVED NAY 2 0 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 2 2 ?009 PERMIT CENTER re e NO PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION S 8171 REGISTER ARQH1IE CHANGE BY OWNER BID INFO BID INFO REVIEW COMMENTS REVIEW COMMENTS REVISION ■ 2 STA OF WASHINGT 3/20/09 1/26/09 1/8/09 12/9/08 10/21/08 DATE NA PROJECT w DRAWN BY DATE SCALE TITLE NUMBER 301 -305 CHK BY YK 9/18/2008 AS NOTED ENLARGED FLOOR PLAN A2.2A ALL COPY RIGHT RIGHTS R EES U H H 3, 3 t f N r• 3 3 f H / I ' 1 ...... i i ‘ '••-,,,„ I e 43 011M111■ 4-, cb 8 ---- ' - -3, ■■• INNIMINO ••■•••• 1••■••■• 4■•■ MMINIMMIM. ■•■•■■■■■ 01•111101•1= 1 i - '1 T 1 (rp" : lt;ri , V , i ' - ' -.., 33 0 ° ...-- .3 33-377:3 L i f MEMINIMMO F TcL TT s CM) 0 31 t - , .31 ,c a A Lr E:3'33 0 . 7A 1 144UPW" -• 3 .111=1■P SCALE 1/8=1 >=111•111•• I FIRE EXIT PLAN I / § p CI +– I — [No I I B I I 1 1 I -- 1 /I i \ A ,„ ,,,. i i '1 -1 t Iii I N C30 NSIR UCT 0 N 0:0 EMERGENCY EXIT. UGHT. ILLUMINATION. EXIT SIGN EXIST3 CG1E:',31TO )N RN NO bo8"i3c1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 0 2009 City of Tukwila BUILDING DIVISION I RECEIVED APR 22 2009 PERMIT CENTER 5 /i9/1 /6\ ADD'L INFO. 03/31/09 NO. REVISION DATE PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 PERMIT SET , NW ARCHITECTURE ARCHITECTURE 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 1EFORE CONSTRUCTION CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION 8171 REGISTERED ARCHITECT ( '11 S TATE OF WASHINGTI NWA PROJECT NO. 301-305 _, P I3HS -1 DRAWN BY - CHK BY YK DATE 9/18/2008 SCALE AS NOTED TITLE FIRE EXIT PLAN NUMBER A2.4 ALL COPY RIGHT RIGHTS RESERVED U H H 3, 3 t f N r• 3 3 f H / I ' 1 ...... i i ‘ '••-,,,„ I e 43 011M111■ 4-, cb 8 ---- ' - -3, ■■• INNIMINO ••■•••• 1••■••■• 4■•■ MMINIMMIM. ■•■•■■■■■ 01•111101•1= 1 i - '1 T 1 (rp" : lt;ri , V , i ' - ' -.., 33 0 ° ...-- .3 33-377:3 L i f MEMINIMMO F TcL TT s CM) 0 31 t - , .31 ,c a A Lr E:3'33 0 . 7A 1 144UPW" -• 3 .111=1■P SCALE 1/8=1 >=111•111•• I FIRE EXIT PLAN I / § p CI +– I — [No I I B I I 1 1 I -- 1 /I i \ A ,„ ,,,. i i '1 -1 t Iii I N C30 NSIR UCT 0 N 0:0 EMERGENCY EXIT. UGHT. ILLUMINATION. EXIT SIGN EXIST3 CG1E:',31TO )N RN NO bo8"i3c1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 0 2009 City of Tukwila BUILDING DIVISION I RECEIVED APR 22 2009 PERMIT CENTER /\ CHANGE BY OWNER 3/20/09 1/26/09 1/8/09 /4\ BID INFO cA A 1 BID INFO REVIEW COMMENTS 12/9/08 REVIEW COMMENTS 10/21/08 DATE NO. REVISION PROJECT TITLE /OWNER ABU —BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799- 1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 II CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REGISTRATION 5171 REGISTER - Q A; H T 4:r K1M STATE OF WASHING ON NO PROJECT N0. 301 -305 = DRAWN BY — CHK BY YK DATE 9/18/2008 SCALE AS NOTED TITLE REFLECTED CLG. PLAN NUMBER A.4.1 ALL COPY RIGHT RIGHTS RESERVED EXIST. EMERGENCY TO. V.I.F. EXIST. EMERGENCY LTG. V.I.F. rim [:21' 5 3/20/09 REFLECTED CEILING P_AN SCALE 1/8"=1 —O EXIST. BATHROOM LIGHT FIXTURES TO REMAIN WITHOUT CHANGE (EN 0 / EXIST. EMERGENCY LTG. V.I.F. f r 0:0 r V EXIST. LIGHT FIXTURES AT FRONT PORCH TO REMAIN WITHOUT CHANGE EXIST. BATHROOM LIGHT FIXTURES TO REMAIN WITHOUT CHANGE EMERGENCY LTG, TYP. I EL1 ' 1 EXIST. EMERGENCY LTG. V.I.F. / EXIST. EMERGENCY LTG. V.I.F., TYP. EXIST. EMERGENCY 0 LTG. V.I.F. NE" C NSTRUCTION vl.lwrilvli I JvwIIVU -N I 11 3,830 1,763 1,588 1,397 1,453 50 260 274 173 1,309 596 484 13,177 06 IBC T AX. ALLOWED) LPA (W /SF) 1.2 1.2 1.2 1.2 1.0 0.5 1.3 1.0 1.2 1.4 0.8 0.8 0.8 MAX. WATTS 4,561.20 2,115.60 2,208.00 1,527.60 1,342.00 25.00 338.00 95.00 328.80 242.20 1,048.80 476.80 387.20 14,396.20 PRAY /WORST TIP MULTI /W. PRAY COMM. SVC. (15) TOTAL STUDY (20) TOTAL OFC. TOTAL STORAGE SUPPLY KITCHEN TOTAL ENT. BOILER /ELEC. TOTAL HALLWAYS TOTAL BATH F. /M. WASH SUBTOTAL PLUMBING SUMMARY (' MALE LIGHTING SUMMARY FLUORESCENT: (2)32 WATTS x 150 EA = 9,600 WATTS PROV'D EMERGENCY LIGHTING CALC. (0.1 WATT /SF) 13,261 SF x 0.1 = 1,326 WATTS REQ'D 60 WATTS x 29 = 1,740 WATTS PROV'D 1/8/09 CLG NOTE 1. ALL MECH. /PLUM. /ELEC /FIRE PERMITS TO BE DEFERRED PERMITS 2. LIGHTING FIXTURES W/ SHATTERPROOF LIGHT SHIELDING USED IN KITCHEN 3. LIGHTING FIXTURE TO BE AT MINIMUM OF 9' -0 HEIGHT FROM A.F.F 4. EXIST. CLG TO REMAIN WITHOUT CHANGE, TYP. 5. RELOCATE LIGHTING FIXTURES PER NEW LAYOUT, TYP. 6. CONTRACTOR TO VERIFY THE REQ'D EMERGENCY LIGHT ILLUMINATION LEVEL., TYP. (1 FC /SF OR 0.1 WATTS /SF) 11' -c) CEILING HEIGHT A.F.F. 6 GWB CEILING RE\Il 2x4 FLUORESCENT LIGHTS — (2) 32 WATTS EACH 6 TRACK LIGHTS FAN /LIGHTS EMERGENCY CIRCUIT (2) 32 WATTS t)08 deb 31 REVIEWED COD E COMPLIANCE APPROVED MM 2 0 2009 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA PR 2 2 2009 PERMIT CENTER CEO EMERGENCY LIGHTING WALL —HUNG INCANDESCENT: 15 WATTS 0 INCANDESCENT — 15 WATTS (RECESSED OR PENDENTED) ® EXIT LIGHT SMOKE DETECTOR ONE WAY SWITCH TWO WAY SWITCH ROOM SOFT OCCU. �`� _ PRA WORSHIP 3,830 Sptl REQ'D (PRINCIPAL ASSEM. AREA) LTI /W. PRAY 1,763 . 2 COMM. SVC. (15) 1,588 106 2 TOTAL STUDY (20) 1,397 70 3 TOTAL OFC. 1,453 15 7 TOTAL STORAGE 50 1 SAFETY SUPPLY - - D106 KITCHEN 260 2 5' -0 X 4' -0 TOTAL ENT. 274 - W107 BOILER/ELEC. 173 1 TOTAL HALLWAYS 1,309 - TOTAL BATH 596 - 4' -O X 4' -0 F./M. WASH 484 - D119 7' -4" x 7' -0" NO SAFE e SUBTOTAL 13,177 X44- . NO. MALE FEMALE W.C. LAV. W.C. LAV. REQ'D (PRINCIPAL ASSEM. AREA) 4 2 4 2 REQ'D (ED. & ACT. AREA) 1 1 2 1 TOTAL REQ'D 5 3 4 3 TOTAL PROV'D 7 5 6 5 NO. SIZE(W- x H) INT D101 - 3' 4" x 7' -0" YES -D1 SAFETY D103 W103 D104 SAFETY W104 4' -0 X 4' -0 D105 SAFETY 4' -0 X 4' -O D106 - REGUIJ W105 W106 5' -0 X 4' -0 SAFETY W107 U W108 U SAFETY D118 4' -O X 4' -0 / U SAFETY D119 7' -4" x 7' -0" NO SAFE e ' e " 0 YES VERIF D121 6' -0" x 7' -0" YES TO MI NO. SIZE(W X H) INT W101 4' -0 X 4' -O YES SAFETY SAFETY W102 W103 6' -0 X 4' -0 SAFETY W104 4' -0 X 4' -0 SAFETY 4' -0 X 4' -O - REGUIJ W105 W106 5' -0 X 4' -0 SAFETY W107 SAFETY W108 U SAFETY W109 4' -O X 4' -0 SAFETY W110 4' -0 X 4' -0 U SAFETY STUDY 3 154 SF OCCU: 8 STUDY 8 229 SF OCCU: 12 CONF. OFC 1 275 SF OCCU: 3 STUDY 2 144 SF OCCU: 7 OFC 2/3 318 S OCCU: 3 OFC 4 208 SF OCCU: 2 D10 0 - D10 - - FLOOR PLAN SCALE 1 /8 " =1' -0" 39' -8 3/4" VENT TO OUTSIDE - (50 CFM) F STUDY 1 94 SF OCC J HALL 573 SF STUDY 4 124 SF OCCU: 6 STUDY 5 188 SF OCCU: 10 STUDY 6 188 SF OCCU: 19 A2.1 5 �\ DRINK'G FNTN TYP. COMM. SVC. 1,588 SF OCCU:106 0 UNISE' 53 SE 0 �- STUDY 7 276 SF OCCU: 23 D109 (D11 EXIST. ELEC. 111 SF x MOP SINK D112 HALL 77 SF POST SIGN @ DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 106." OFC 91 S 40' -7 1/4" GROSS FL. AREA: 14,310 SF (FRONT EVE: NOT INCLUDED): 1,431 SF - VENT TO OUTSIDE - (100 CFM EA.) F. WASH 359 SF VENT TO � OUTSIDE (50 CFM) \--FD STOR. 50 SF W (EXIST.) 170 SF FD ®Q CQ MULTI .PRA 1,763 SF OCCU: `ifl NE % SF PR. 31 -2 3/4" EXIST. CANOPY 431 SF 143'-1 1/4" Y 799 F 799 / EXIST. ENT. 100 SF IAPER D118 VENT TO -OUTSIDE (50 CFM) VENT KITCH. (BREAK) ®OUTSIDE 260 SF (100 CFM) EXIST. BOILER 62 SF CD - DRINK'G FNTN HALL 431 SF SEE A2.5 STOR D112 D115 OFC (AUDIO) 140 SF UTIL. 15 SF K 83 SF i1. WASH POST SIGN @ DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 0 - .MENT_I9 ..QUJ S!QE (125 CFM EA.) M. - (EXIST.). 267 SF FD ENT. 82 SF 62' -9 1/4" VENT TO OUTSIDE (50 CFM) - -...... 6' -4 3/4 DRINK'G FNTN D11 OFC. -ADMIN 2 190 SF W109 OFC.- ADMIN. 1 170 SF 64 -1 1/4" POST SIGN 9 DOOR FRAME "THIS DOOR MUST REMAIN UNLOCKED DURING OCCUPIED." "MAX. OCCUPANCY LOAD 5 00 NOTES 1. ALL LUMBERS IN CONTACT WITH CONC. TO BE PRESSURE TREATED. 2. NO STRUCTURAL CHANGES. 3. NO CHANGES AT EXTERIOR. 4. SEPARATE MECH. /ELEC. /FIRE PERMIT TO BE APPLIED. 5. A SEPARATE SPRINKLER PERMIT BY CONTRACTOR TO BE APPLIED AS NECESSARY. 6. SEE FIRE EXIT PLAN (A2.4) FOR EXIT LIGHT INSTALLATIONS. 7. ALL EXIT LIGHTS AND FIRE ALARM SYSTEMS TO BE DONE BY LICENSED CONTRACTOR. 8. ALL DOOR HARDWARES TO BE LEVER TYPE AS REQUIRED, TYP., BALDWIN 5460 OR BETTER. 9. MIN. 50 CFM AT BATHROOM, TYP. SEE FL. PLAN FOR REQ'D CFM. 10. NO COOKING AT KITCHEN /BREAK RM. 11. EXIST. PLUMBING FIXTURES TO REMAIN WITH NECESSARY REPAIR WORKS. 12. A SEPARATE PLUMBING PERMIT FOR THE NEW WORKS TO BE APPLIED. 13. ALL EXIT DOORS TO HAVE PANIC HARDWARE, TYP. 14. SEE A2.2, A2.2A FOR MORE DETAIL INFO OF FL. PLAN. CORR. 145 SF OFC -IMAM 161 SF CM CO CM NEW CONSTRUCTION OCCUPANCY SUMMARY PLUMBING SUMMARY ('06 IBC TABLE 2902.1) DOOR SCHEDULE WINDOW SCHEDULE NOTES: 1. DOOR AND WINDOW FRAMES TO BE HOLLOW METAL. 2. DOOR HARDWARES TO BE LEVER TYPE OR DETERMINED BY OWNER 3. PLUMB'G FIXTURES AND HARDWARES, ACCESSARIES TO BE DETERMINED BY OWNER 0 IN FIELD TCH IN DIMS AND COLOR ETC. 1/8/09 EXIST. CONSTRUCTION N - YP. WALL SCALE 1 1/2 " =1' -0" SCALE 3/8 " =1' -0" FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fiw' a py and nditions is acknoww* ged: GALVANIZED MTL STUDS WHERE IN CONTACT W/ CONC., TYP. P.T.D S.D. r EGRESS WIDTH PER OCCU. SERVED (TABLE 0.15 x 130 = 19.5" REQ'D bo8 ROOF ASSEMBLY 3/8" DEFLECTION SPACE FIRE STOP SEALANT AT FIRE RATED PARTITIONS., TYP. ACOUSTICAL SEALANT AT SOUND RATED PARTITIONS, TYP. LOCATED AT INNER LAYER OF GWB 5/8" TYPE 'X" GWB ON BOTH SIDES (USE WATER RESISTANT BOARD AT KITCHEN AND BATH RM.) FIRE BLOCKING AT MID OF WALL METAL STUDS @ 16" O.C. WASHROOvI (WADO) City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 3 2009 City of Tukwila BUILDING DIVISION � REVISION N0.3 1005.1) : RECEIVED JUN 1 9 2009 PERMIT LENTEN L13 P.T.D. - CERAMIC TILES FLOOR AND WAL .. P. SOAP DISPENSER P.T.D.: PAPER TOWEL DISPENSER 76\ N0. b /I5 /oq 03/31/09 DATE dcC 0(40 ADD'L INFO. REVISION PROJECT TITLE /OWNER ABU -BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799 -1379 PERMIT SET NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 BEFORE CONSTRUCTION CONTRACT IS SIGNED, OWNER OR CONTRACTOR NOTIFY ARCHITECT OF ANY DISCREPENCIES, CONFLICTS, CLARIFICATIONS. REG TRATION V) 8171 REGI TEED ARCHITECT G NG TA 0' ' ' SHINGTO NWA PROJECT NO. DRAWN BY DATE SCALE TITLE NUMBER iPa 301 -305 CHK BY 9/18/2008 AS NOTED FLOOR PLAN, WALL SEC. WASHROOM ELEV. A2.1 YK ALL COPY RICHT RIGHTS RESERVE°