Loading...
HomeMy WebLinkAboutPermit D08-449 - CASCADE YARNS - WINDOWSCASCADE WARNS 1224 ANDOVER PK E D08 -449 Parcel No.: Address: Suite No: Owner: Name: Address: Phone: doc: IBC -10/06 1224 ANDOVER PK E TUKW Tenant: Name: CASCADE YARNS Address: 1224 ANDOVER PK E , TUKWILA WA Cityilf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Contact Person: Name: VICKI SOMPPI Address: 22002 64 AVE W STE 2C , MOUNTLAKE TERRACE WA 98043 Phone: 425 - 670 -6706 X 101 Contractor: Name: DYNA TECH CONSTRUCTION CORP Address: 1829 188TH N.E. , ARLINGTON, WA 98223 Phone: Contractor License No: DYNATCC088CR DESCRIPTION OF WORK: PROVIDE NEW WALL OPENING (EXTERIOR) AND STOREFRONT WINDOWS Value of Construction: $3,500.00 Fees Collected: $209.92 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: III -B Occupancy per IBC: 0008 * * continued on next page ** Permit Number: D08 -449 Issue Date: 02/12/2009 Permit Expires On: 08/11/2009 Expiration Date: 06/18/2010 D08 -449 Printed: 02 -12 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: Land Altering: Volumes: Cut Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied The granting of this permit does not pres construction or the perfgrmance of work. doc: IBC -10/06 City ATukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N Start Time: End Time: Private: Profit: N Private: 0 c.y. • Permit Number: Issue Date: Permit Expires On: Size (Inches): 0 End Time: Fill 0 c.y. Public: Non - Profit: N Public: D08 -449 02/12/2009 08/11/2009 Date: DA i /ft ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating II authorized to sign and obtain this development permit. / g Date: �-// / / Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -449 Printed: 02 -12 -2009 Parcel No.: Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1224 ANDOVER PK E TUKW CASCADE YARNS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of arty other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** Permit Number: D08 - 449 Status: ISSUED Applied Date: 09/30/2008 Issue Date: 02/12/2009 doc: Cond -10/06 D08 -449 Printed: 02 -12 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: doc: Cond -10/06 D08 -449 Date: 2// 2-A ordinances governing or local laws regulating Printed: 02 -12 -2009 Contact Person: E -Mail Address: Company Name: f.( A Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION King Co Assessor's Tax No.: 23 CI- Site Address: 1224 A N pp i t= a. "Pik-eK Suite Number: 1 2.2 1 Floor: Tenant Name: `ileXi4VG y N New Tenant: LI .... Yes Property Owners Name: 1.4 ft -12 i ce. .(., t I4 Mailing Address: 51(0o I, A CONTACT PERSON -- who do we act when your permit is ready to be issued Name: V lC C',Okxppi Day Telephone: .425—(D Wir)(1) )( f1)1 Mailing Address: 2-2_ WZ (pi, 7)1 jive Ske 2C, M t k. -- rei'Y - : KA C/ City State Zip E -Mail Address: ' f (C,k) S 0. 00(111415 IC.f) , C ()M Fax Number: - x{25 - 771 _ S 2 ) 9 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5));' Company Name: fl! Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: lib1 {fie I/ Or990 Mailing Address: 2-2-CDC) TFt Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** vi Ck+ ` Vice Col/ neildesk(» con() Q:\Applications\Forms - Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh MFG 1SLiAl\i0 City Building Pernilt No. 9 1 +4 c7 Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) WA State Zip City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City State Zip Day Telephone: 12s- (g -O(D k r/D Fax Number: 25 - 74 - ENGINEER OF RECORD -'All plans must be mped by Engineer of Record Mailing Address: cit Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFORNTION — 206- 431 -3670 Valuation of Project (contractor's bid price): $ , 5Q 0 Existing Building Valuation: $ Scope of Work (please provide detailed information): )V14. ¥\L & (A) (1 1 (Dpn't C\ 11 ex -e vi ci 1'") UYld -oye- - w \vv-doc,) S Will there be new rack storage? ❑.... Yes Uncovered Deck ].. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 2 "° Floor Floor Floors thru Basement Accessory Structure *' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Interior Remodel Addition to Existing Structure Type of Construction per IBC lit— Type of Occupancy per IBC Ise PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft):'14 1 Q?, Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 14C C V)C't 0 Compact: N 0 C 1/1 1V R C Handicap: No i hwy Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑ None ❑ Other (specify) Page 2 of 6 PERMIT APPLICATION NO1 — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit k` The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each,'; -The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: ) t.1 ') 1 ■ Date:' 3() = ?c - (i Print Name: \i 1 `- .)L i t , I'fir' d Day Telephone: ''1 2 . L / '6' rO f -' i Mailing Address: ZZcx , (oTT-t Ave v.), f ..2.0.- M4-11, -(Q tA.111 c i City State Zip Date Application Accepted: 9 -3o -0e Q:\Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: Staff Initials: Page 6 of 6 PLUvIBING AND GAS PIPINk ERMIT INFORMATION - 206 -43- 670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration N Fixture Type: Bathtub or combination bath /shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Building sewer or trailer park sewer Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Valuation of Plumbing work (contracto - arice): $ Valuation of Gas Piping work (contractor's : ce): $ Scope of Work (please provide detailed informat Building Use (per Intl Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outl - eing installed and th Qty Fixture Type: Drinking fountain o r . er cooler (per head) Food -waste gri commercial Floor drai Shower, _Ie head trap Lavat ater system — per n (inside building) epair or alteration of water piping and /or water treating equipment Q.\Applications\Forms- Applications On Line\3- 2006 - Permit Application.doc Revised: 9 -2006 bh Q ty ewer: Fixture Type: Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Water heater and /or vent Repair or alteration of drainage or vent piping City Day Telephone: Fax Number: Expiration Dat uantity below: Qty e Fixture Type: Gas piping outlets Additio medical gas inlets/outl . — six or more Medical gas • ing system serving one to '' . e inlets /outlets for s cific gas Zip QtY Page 5 of 6 Parcel No.: Address: 1224 ANDOVER PK E TUKW Suite No: Applicant: CASCADE YARNS Receipt No.: R08 -03392 Initials: WER User ID: 1655 Payee: CONNELL DESIGN City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.cidukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15860 209.92 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000/322.100 000/345.830 000/386.904 RECEIPT Account Code Current Pmts Total: $209.92 • Permit Number: D08 -449 Status: PENDING Applied Date: 09/30/2008 Issue Date: Payment Amount: $209.92 Payment Date: 09/30/2008 10:22 AM Balance: $0.00 124.50 80.92 4.50 77.2 )9/7, 7707 73TP.:.. 2:)9.72 dot: Receipt -06 Printed: 09 -30 -2008 COMMENTS: k0,4_1 1,, cked r /x Type of Inspection: \ F:11 B� ,' t �-' M ( (....�1 f-e , J , s-, ( .4- ABC Date Called: (, M . ^ 1 l A., ri z, /-1( c. p o . f c d .m. 6 _ t -del p.m. Requester: Phone _______, n , Project: (AC A 4- �� I Type of Inspection: \ F:11 B� ,' t �-' Address: 1 ? ZA AnOo Gam+' Date Called: (, M . ^ 1 l Special Instructions: nn 3-41 z U 5 sk CA� (t 4 " kq c/ r-,‘ n ,k r -er- i Date Wanted: c d .m. 6 _ t -del p.m. Requester: Phone FfO ` 00Y-5 3 INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12- ■" - • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3610 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. Inspectg Date: L ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. d i Receipt No.: 'Date: COMMENTS: yi,v^i Type of Inspectio 0 (1 t) 1-- e', . Date Called: _ Special Instructions: J+) J Ll � Date Wanted: — i t C � a.m, ` d T p.m. Requester: ' .7: (7 Phone o: 2.5 q ivie/.. c. r 1 1 1 `` LG \\ \1 Project: (.. Are,frile yi,v^i Type of Inspectio Address: ^ (2 21 /'`I / p 1e.. e Date Called: _ Special Instructions: J+) J Ll � Date Wanted: — i t C � a.m, ` d T p.m. Requester: Phone o: 2.5 q '065- INSPECTION NO. INSPECTION RECORD Retain a copy with permit Oo -44 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. Inspector: Date: 1 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: (Date: COMMENTS: Type of Inspection: r, AA( ) , ( A 1 Address: Adao Jer r �. 177. t'.^�� Date Called: CO < ;C 11J (Lop IT Fi 6 Ak S e.--: A ( i2,-S P. c -- J A fdlLi : C• eate . tP,"c1 O 6I0g5 /u o 1 ` r A II 1 Project: (ASC-A ■14✓ Type of Inspection: r, AA( ) , ( A 1 Address: Adao Jer r �. 177. t'.^�� Date Called: � Special Instructions: e yt. Date Wanted: 'A - (, q m . P.m J , f �� j1 . � � CJVIC I Pr z _ i p C C T 1( .S� . A( P P ' J '‘( Requester: Phone No: O 6I0g5 INSPECTION RECORD ���� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. t ai E] $60.00 REINSPECTION FEE REQUIRED. rior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. AkA. Inspect r: Date: / 4 Receipt No.: Date: COMMENTS: (J ,/1_ 11 i ¢1 Type � I /4 t 2 //1/ �� i Q,9vn1k)t, - APnO (Air-0 Sit kir94 -- 4 0 - 1 -- P4. -4 LA b r H f e Not..9 , P Aw 5 Pe P - .t. :1 c Date ?anted: / >�� G . -.2 /// :3) O,1,4L/ v.) 0 - Requester: 1 OA// flfN4IU/h #J fs4 L41 h'9 gra1/ /( '(-/ ..;:; /// N Pro , /l //IX �f ,91� Type � I /4 t 2 //1/ Address Called: Special Instructions: Date ?anted: / >�� G . -.2 /// P.m. Requester: Phone No: �2 - 76 6 • 6017.3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1}�, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Insp;cto d)/(5 Corrections required prior to approval. Dagq/p 60.00 REINSPECTION FEE RE UI D. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Engineering o Consulting o Testing June 10, 2009 Attn: Mr. Terry Proctor Dyna -Tech Construction 1829 188 Ave NE Arlington, WA 98223 Subject: Dear Mr. Proctor: Information To Build On Final Letter Special Inspection and Testing 742 -90032 Cascade Yarn 1224 Andover Park East Tukwila, Washington NPermitiNCID.0:8 -1 49 qE r JUN 10 200 Guivi;d,u■It )1 D eveLOPMENT In accordance with your request and authorization, Professional Service Industries, Inc. (PSI) has performed special testing and inspection services for the above referenced project. The special inspections provided on this project were: 0 Load Test of Anchors Inspection To the best of our knowledge, all work listed above that PSI was scheduled on -site to verify, has been found to be in general accordance with the approved plans and specifications, approved changes from the FOR and Chapter 17 of the 2006 International Building Code. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 589 -1804. Respectfully submitted, Professional Service Industries, Inc. .(. J. _ Angela J. Bonney Project Manager /ajb 9 1CC1Ctfl1Twkwil4 Professional Service Industries. Inc. • 10025 South Tacoma Way. #H1 • Tacoma, WA 98499 • Phone 253/589-1804 • Fax 253/589 -2136 ED AND NICK ON SITE FOR LOAD TESTING OF ANCHORS INSTALLED IN THE NORTH ELEVATION. CONTACTED ALLAN TUCKER OF ENGINEERS NORTHWEST FOR LOAD VALUE OF 20008. TESTED 2 ANCHOR OF 16 TOTAL - ONLY 4 ANCHORS PER STRONG BACK WERE ACCESSIBLE AT MEZZANINE LEVEL - LOWER AREA WAS COVERED. 2 ANCHORS = 10% PER CONTRACTOR - 4 1/2" EMBEDMENT WITH 5/8 ALL - THREAD UTILIZING HILTI HY 150 ADHESIVE. BOTH TESTS UTILIZED AN ENER PACK RCH 121 12 TON RAM WITH A 1000 PSI GAUGE LOADED TO 680 PSI WHICH EQUALS 2000# T. BOTH TESTS CONSIDERED RESTRAINED DUE TO STRONG BACK PLATES IN PLACE. 2 MAN CREW CALIBRATION DATA ATTACHED. 4 TOTAL HOURS 4 EQUIPMENT IDENTIFICATION AND SIN #: COPIES TO: INSPECTOR: DATE: :,:: ITEM : INS P CrT. U; :::::.: ::.::.';:;::;:.:.:: AP02O00:PLANS:ARE : ' :. :.: .. :', ,::::`.` ' • > < ::• :CONFORMIN :: X : ::::::. CLIENT ENGINEER ARCHITECT CONTRACTOR BUILDING DEPT. SUPPLIER NICK JACKSON ED SMITH May 19 2009 X _ FIELD CONTACT: I I DATE: . . : ...,..._..:: : NONCONFO ,0 ED AND NICK 2 MAN CREW 4 TOTAL HOURS 4 Information To Build On Etfraibloorie • Consideing • Mo SEATTLE DIVISION 24113 50TH AVE W MOUNTLAKE TERRACE, WA 98043 (425) 248 -2400 • FAX (425) 248-2401 6002 0 tint TACOMA DIVISION Cl3A ^ A 8499 WAY, SUITE H7 SO MA, WA (253) 569 -1804 • FAX (253) 589 -2136 Dyna -Tech Construction 1829 188th Ave. NE Arlington WA. 98223 PROJECT NO: PERMR:NO. MVN1 IP141;iTY :: ENGIINfEii; >::: . ARC.HkTECT .:' CONTRACTOR PROJECT:ADDRESS.:: 742 -90032 DATE May 19 2009__ _ _ W.O 1224 Andover Park E. - Tukwila RT 'TN* report is provided for the information of the client only. The reproduction of this report, by any method, one Its transmittal to a third party by any means, except In full, without the lull permission of Professional Service I00usuies. Inc., Is prohibited' 'This certification attests to the accuracy of the results obtained from the actual lest performed and/or obseNations mode wllNn the defined scope or the work. Certification shall not tie construed to represent an inspection, approval or acceptance of other associated work Or Warranty Of design or worttabilay of the specification requirements • Certified Report by Professional Service Industries: EDWARD A. SMITH TS - 98 -1 ZO'd 9S: 600Z S cant 'KTZ- 68S-SZ:XP NAME Date FR 63755 ❑ PORTLAND DIVISION 6032 NO. CUTTER CIR. SUITE 480 PORTLAND, OR 97217 (503) 289 -1778 • FAX (503) 289-1918 ON OFF ST OT May 19, 2009 ISd MILES TO: . L ∎ v . L - , \ c. FROM: ...tx.cv, 9 \ , cNr.S SUBJECT; r DATE: DATE: — �' I FAX # (?o lo I- k\ – 36 105 # OF PGS, INCLUDING COVER 2 Ji r iaw Information ToBuild On Engineering • Consulting • Testing FAX t0025 South Tacoma Way - Suite HI Lakewood, Washington 98499 V (253) 589.1804 F (253) 589.2136 If You Have Questions Concerning This Transmittal Or Do Not Receive This Document In Its Entirety i0 'd 9S: 2I 600Z S unf Please contact us at 253-5 CONFIDENTIALITY NOTICE The documents accompanying this telecopy transmission contain information that is legally privileged. The information is intended only for the use of the recipient named above only. If you have received this telecopy in error, please notify us immediately by telephone to arrange for the return of the telecopy document to us. You are hereby notified that any unauthorized disclosure; copying distribution or reliance on the telecopy information is strictly prohibited. 92IZ- 68s— � SZ:XPJ ISd CLIENT : ADDRESS ON SITE FOR LOAD TESTING OF ANCHORS INSTALLED IN THE NORTH ELEVATION. CONTACTED ALLAN TUCKER OF ENGINEERS NORTHWEST FOR LOAD VALUE OF 2000 #. TESTED 2 ANCHOR OF 16 TOTAL - ONLY 4 ANCHORS PER STRONG BACK WERE ACCESSIBLE AT MEZZANINE LEVEL - LOWER AREA WAS COVERED. 2 ANCHORS = 10% PER CONTRACTOR - 4 1/2" EMBEDMENT WITH 5/8 ALL - THREAD UTILIZING HILT! HY 150 ADHESIVE. BOTH TESTS UTILIZED AN ENER PACK RCH 121 12 TON RAM WITH A 1000 PSI GAUGE LOADED TO 680 PSI WHICH EQUALS 2000# T. BOTH TESTS CONSIDERED RESTRAINED DUE TO STRONG BACK PLATES IN PLACE. W.O. ArlinnVon, WA. 98223 CALIBRATION DATA ATTACHED. ATTENTION P,O.: NO: PROJECT...:...:. :. .. • ENGINEER::. TOTAL HOURS Mr. S octor ARCHITECT D08 -449 CONTRACTOR .::::: ::::: — EQUIPMENT IDENTIFICATION AND SIN #: COPIES TO: INSPECTOR: DATE: ITEMS:INSPECTED.TO:: : : APPROVED PLANS ARE: CLIENT ENGINEER ARCHITECT CONTRACTOR BUILDING DEPT. SUPPLIER NICK JACKSON ED SMITH May 19, 2009 FIELD CONTACT: I DATE: CONFORMING • . . NONCONFORMING CLIENT : ADDRESS Dyna -Tech Construction PROJECT:NO :.:` ::. 742 -90032 DATE May 19, 2009 1829 188th Ave. NE PERMIT.NO:... .: W.O. ArlinnVon, WA. 98223 MUNICIPALITY:: ATTENTION P,O.: NO: PROJECT...:...:. :. .. • ENGINEER::. TOTAL HOURS Mr. S octor ARCHITECT D08 -449 CONTRACTOR .::::: ::::: — Cascade.Y n PROJECT ADDRESS:::: 1224 Andover Park E. - Tukwila ED AND NICK 2 MAN CREW 4 TOTAL HOURS 4 ® Information ® _ To Build On En • Canssaiting • Thenting SEATTLE DIVISION 24113 56TH AVE W MOUNTLAKE TERRACE, WA 98043 (425) 248 -2400' FAX (425) 248 -2401 17 , E!VED f M ISI S 1 Q 0 n j ;' . SUITE HI TAP MA WA 98499 ,.,e 53) 589 -2136 'This report is provided for the information of the client only. The reproduction of this report, by any method. and as transmittal to a third party. by any means. except in full, without the full permission of Professional Service industnes, Inc., is prohibited.' This certification attests to the accuracy of the results obtained from the actual test performed and/or observations made within the defined scope of :he work. Certification shall not be construed to represent an inspection approval or acceptance of other associated work or a warranty of design or workability of the specification requirements' Certified Report by Professional Service Industries: EDWARD A. SMITH TS-98-1 NAME Date FR 63755 PORTLAND DIVISION 6032 NO CUTTER CIR. SUITE 480 PORTLAND, OR 97217 (503) 289-1778 • FAX (503) 289 -1918 ON OFF ST OT May 19, 2009 MILES We get buildings built. STRUCTURAL ENGINEERS Engineers Northwest Inc., P.S. b Cascade Yarn Office Remodel 1224 -1226 Andover Park E TUKWILA, WASHINGTON ADDITIONAL OPENING STRUCTURAL CALCULATIONS September 2008 ENW JOB NO. 88134008 _ II .. L �D ^..�.eca. _ ...-.� v RECEIVED SEP 3 0 2008 PERMIT CENTEF • • • • C C OMPLIANCE APPROVED OCT 0 9 2009 City ILO 6869 Woodlawn Avenue NE • Seattle, WA 98115 206.525.7560 • fax 206.522.6698 www.enwseattle.com N DIVISION ONA . • ,. ^r^1 JOB # 8000067.000 FOR : - DESIGN of Square Tube Steel (HSS) Strong backs @ new wall openings, etc. WALL STRONG BACK LOCATION:- WALL HSS. STRONGBACK OPENING Conn. must occur between 1st. conn. above top of door & floor (60" o/c max.) Input cells = Property of Engineers Northwest, Inc., Seattle - Use by others unlawful u 9.67 I 2.00 I 0.00 ft _ Trial Sq. HSS size = I PROVIDED = IRE= .= S PROVIDED = SREQ'D.= ACTUAL DEFLECTION = ALLOWABLE DEFL.(12H /150) = ENGINEERS - NORTHWEST INC. P.S. 6869 WOODLAWN AVE. N.E. (SUITE 205) SEATTLE, WA. 98115 w ft z - Existin • North Elevation w/ New Relite HSS TOP = 16.33 ft. , ., , . W3 ft _ 3 - 15X5X5/16 1 19 in. 18.05 in. 7.61 in . 3.06 in . 1.82 in. 1.92 in. JOB NAME :- Cascade Yarn y Strongback Pagel ft_ h3— h ft = z -hft - h Duration factor = wind Toad = seismic load = lateral design load = T =C= T =C= M ExIST = M TUBE = SHEET ROOF ( Wall support ht. ) 0.33 4.00 3.00 9.00 H uPLF= 1 35 1.33 18.50 19.70 19.70 2979 2575 9695 10301 24.00 strength psf psf psf # (conn.just above door) # (top connection) ( IN WALL HEIGHT "H" ) # -ft 2979 # @ WALL CONNS 1616 # @ TS BASE CONN. WALL WITH HSS 5X5X5/16 STRONG BACK IS OK FOR LATERAL LOAD SHOWN HSS 5X5X5/16 weighs 19.08 plf OF Rev. 6/25/04 loading 8/20/2008 STRBACK.XLS J Input = Job number : Job name : Cascade Yarn Controls Wall design at high roof at low roof Controls Wall Parapet only design Non-Structural Wall Element Force ( Non - Bearing - Non-Shear Walls Property of Engineers Northwest, Inc., Seattle - Use by others unlawful 08000067 Walls - ASCE 7 -05 Section 12.11.1 & 2 also Section 13.3, 4 & 5 In s ut Wall weight , Ww = Are the walls bearing or shear walls? Ip = ap = Rp = Top of wall elevation (parapet) = Elevation of top of wall lateral support (max.) = Elevation of top of wall lateral support (min.) = IE Sds = Seismic Design Category (SDC) = Is Diaphragm considered Flexible? z/h = ENGINEERS - NORTHWEST, INC.P.S. 6869 WOODLAWN AVE. N.E. (SUITE 205) SEATTLE, WA. 98115 Fpu = Fp = Fp = M design = M design = M design = M design = ASCE 7 -05 Section Fpu = Fpu = Fpu = Fpu = Fp design = Fp design = M design = M design = Shaded cells 2.5 31 31 31 1 0.933 D Y 1.0 Output SHEET OF psf Walls are (Structural) Section 11.2 ASCE 7 -05 Section 13.1.3 Parapets braced to framing below its cg. ASCE Table 13.5 -1) Parapets braced to framing below its cg. ASCE Table 13.5 -1) ft. from " ASCE EQ." Sheet ft. ft. Wall Anchorage & Parapets Section 13.3.1 Ww = wall weight (psf) ASCE 7 -05 Section 1211.1 Concrete & Masonry Wall Lateral Loading - Out -of -plane force. 0.373 *Ww Main wall design (USD) 0/62 *Ww Main wall design (ASD @ 0.7 *E) 19.7 psf ASD 2366 ( #- ft. /ft.) (ASD) simple span (neglecting parapet) 2366 (#- ft. /ft.) (ASD) reduced for cantilevered parapet 2366 (#- ft./ft.) (ASD) simple span (neglecting parapet) 2366 (#- Rift.) (ASD) reduced for cantilevered parapet 13.3.1 Concrete & Masonry Parapets - Out-of -plane force. 1.120 *Ww (Eq. 13.3-1) 1.493 *Ww (Eq. 13.3 -2) maximum 0.280 *Ww (Eq. 13.3 -3) minimum 1.120 *Ww USD - Controls 0.784 *Ww Working (0.7*E factor ) 58.8 psf (ASD @ 0.7*E 0 (ft-ft./ft.) (ASD @ 0.7*E) min. parapet @ 0 ft. high 0 (ft-ft./ft.) (ASD @ 0.7 *E ) max. parapet @ 0 ft. high ASCE 7 -05 Sections 12.11.1, 12.11.2 & 13.3.1- Concrete & Masonry Wall Anchorage - Out -of -plane force. Wall Fpu = 280 (plf) Minimum USD @ point of anchorage Controls Anchorage Force Cs = 1.120 Wall anchorage Tributary Weight = 1163 (plf) Max.@ point of anchorage Fpu = Cs * Tributary Weight Fpu = 1302 (plf) USD @ point of anchorage Fp design = 912 (plf) (ASD @ 0.7 *E) at point of anchorage ASEC 7 -05 Section 13.3.1 Non - Structural Wall Elements - Out -of -plane force. ap /Rp = 0.4 Wall Element ASCE Table 13.6 -1 Fpu = 0.448 *Ww (Eq. 13.3 -1) Fpu = 1.493 *Ww (Eq. 13.3 -2) maximum Fpu = 0.280 *Ww (Eq. 13.33) minimum Fpu = 0.448 *Ww USD - Controls Fp design = 0.314 *Ww (ASD @ 0.7*E) Wall Anchorage - NOTE:- 1.) For wall anchors that are not embedded 8 diameters minimum multiply the above wall anchorage factor by 2.0 for the anchor loa 2.) For design of steel elements of the wall anchorage system multiply the above anchorage loads by a factor of 1.4. Sec.12.11.2 3.) For design of wood elements of the wall anchorage system the minimum net thickness of these wood elements must be 2 -1/2 ". 5/21/07 Controls Wall design Controls Parapet only design Controls Com . • vent Seismic 8/20/2008 Walls Copy of ASCE7- 05Seismic.xls HEIGHT OF PARAPET, hp = WIND VELOCITY, v = SITE EXPOSURE _ IMPORTANCE FACTOR, I = TOPOGRAPHIC FACTOR, Kzt = DIRECTIONALITY FACTOR, Kd = VELOCITY PRESSURE COEFF. Kz = Roof Design height for (qh) = Parapet Design height for (qh) = ENGINEERS - NORTHWEST, INC.P.S. SHEET OF 6869 WOODLAWN AVE.N.E. (SUITE 205) 5/25/07 SEATTLE, WA. 98115 PROJECT NUMBER: 08000067 PROJECT NAME: Cascade Yarn LOCATION: Tukwila, WA Property of Engineers Northwest, Inc., Seattle - Use by others unlawful Wind on Component & Cladding (Walls & Parapets) - ASCE 7 -05 Section 6.5.12.4.4 INPUT from Sheet 1 qp = qp = INPUT from Sheet 2 Effective Wall Wind Area "A" = OUTPUT 11.12 psf 11.12 psf = Positive pressure from Wall Figure 6 -11A to the front of the parapet = Negative pressure from Roof Figure 6 -11 B to D to the back of the parapet = Negative pressure from Wall Figure 6-11 A to the front of the parapet FIg 6 -11A Positive Wall Pressure Zones 4 & 5 Front Wall Design @ 272 sq.ft. trib. (Inward) = 9.47 psf Wall Design 272 sq.ft. trib. (Outward) = -10.47 psf Wall Design @ 272 sq.ft. trib. (Outward at Corners) = -10.94 psf At top of parapet At top of parapet for Zones 4 & 5 At roof height for Zones 2 & 3 Parapet Load Case A Section 6.5.12.4.4 p = qp ( GCP -0Cpi) (Eq. 6 * ' GCpi is not included as the parapet is assumed to be nonporus FIg. 6 -11 B to D Fig 6 -11A Negative Roof Negative Wall Pressure Pressure Zone 2 or 3 Zone 4 or 5 Back Front Location Gcp Gcpi * p Positive: Zones 4 & 5 per Fig 6-11 A Parapet 0.6721 0.00 7.47 psf Negative : Zone 5 per Fig 6-11A Parapet -0.8042 0.00 -8.94 psf Negative : Zone 4 per Fig 6-11A Parapet -0.7621 0.00 -8.47 psf Negative : Zone 3 per Fig 6 -11 B,C or D Roof comers -0.9900 0.00 -11.01 psf Negative : Zone 2 per Fig 6-11 B,C or D Roof - 0.9900 0.00 -11.01 psf Components & Cladding p design Parapet Load Case A Total wind pressure at corners = 18.48 psf Total wind pressure not at corners = 18.48 psf Parapet Load Case B Use for Parapet Design Total wind pressure at corners = 16.41 psf Total wind pressure not at corners = 15.95 psf Use for Wall Design Parapet Load Case B Section 6.5.12.4.4 Not At corners At corners GCp GCp 0.6721 0.6721 - 0.9900 -0.9900 - 0.8042 -0.7621 FIg 6 -11A Positive Wall Pressure Zones 4 & 5 Back 8/20/2008 Copy of ASCE7- 05WindMeth2.xls 02 -02 -2009 VICKI SOMPPI 22002 64 AVE W STE 2C MOUNTLAKE TERRACE WA 98043 RE: Permit Application No. D08 -449 1224 ANDOVER PK E TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 09/30/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 03/29/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 03/29/2009. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: fer Marshall t Technician Permit File No. D08 -449 • Cizy of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter .Boulevard, Suite #100 0 Tukwila, Washington 98188 • Phone: 206- 431 -3670 0 Fax: 206- 431 -3665 iERIN9T COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -449 PROJECT NAME: CASCADE YARNS SITE ADDRESS: 1224 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # DATE: 09 -30 -08 After Permit Issued DEPARTMENTS: B visi P blic Works i r: Structural � 1-Y '`'�4 , Ib -2-o, DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Documents/routing slip.doc 2 -28 -02 Fire ' Preventio � b' 'Zr Incomplete REVIEWER'S INITIALS: TUESITHURSROUTING: Please Route v Structural Review Required n DATE: DATE: Planning Division Permit Coordinator DUE DATE: 10-02-08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 10-30-08 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions a Not Approved (attach comments) Notation: REVIEWER'S INITIALS: 1_ Permit Center Use CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 24345409 02/11 /2002 Until Cancelled $12,000.00 01/18/2002 3 WESTERN SURETY CO 24345409 02/11/2001 02/11/2002 $6,000.00 12/18/2000 2 DEVELOPERS INS CO 178240C 02/11/1995 Until Cancelled 03/18/2001 $6,000.00 02/16/2001 1 CBIC 632371 02/11/199202/11 /1995 $6,000.00 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 21 JAMES RIVER INS 00024838 06/18/200806/18 /2009 $1,000,000.00 06/17/2008 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Led to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company DYNA TECH CONSTRUCTION UBI No. CORP 3606527375 Status 1829 188TH N E License No. License Type ARLINGTON WA 98223 SNOHOMISH Corporation Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601369875 ACTIVE DYNATCC088CR CONSTRUCTION CONTRACTOR 2/19/1992 6/18/2010 GENERAL UNUSED Business Owner Information Name PROCTOR, HAROLD L Role Effective Date 01/01/1980 Expiration Date Bond Information Insurance Information • • Page 1 of 3 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= DYNATCC088CR 02/12/2009 CASCADE Y EXTERIOR RELJTE R4 ,,, - .0y r ENG'D: A.TUCKER DWN: D.G. JOB NO: 08000067 PARTIAL PLAN / � , � k DATE: 08 -20 -08 SHEET: S1 SKI NORTHWEST, INC. ENGINEERS NORT , 6869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 98115 '�b��°ii 1 g10NAL % gl /OP EXISTING 6" TILT UP CONC. PANEL r r e F COPY 9' -8" R.O. NEW OPNG 3' -6" PARTIAL PLAN Q tO8 '*(9 — I rttdIt � PLIAN CODE COMPLIANCE O ®!IE® APPR OCI 0 9 008 ity Of Tu ila B ILDIN DIVISION RECEIVED SEP 3 0 2008 PERMIT CENTEI- t CASCADE YARN EXTERIOR REM - . . , . .. # Aso � � A * Ibcl 1 oxeL ENG'D: A.TUCKER DWN: D.G. JOB 08000067 SECTION A -1 '— DATE: 08 -20 -08 SHEET: S Si ENGINEERS NORTHWEST, INC. SEATT E, WASHINGTON 98115 Li co E 00 v 1 rn 0 O I i rn 0 0 N co 0 0 0 0 co I (0 Y 0 0) c 2 r N N } 0 v ce W " 0 m ° 0 0 0 IX W4 Do Zo Est4 CLAP Ft EA. H. - S. . WELD ALL UND) 44 [15'-al H.S.S. CO 5x5x EA. SIDE OPNG. EQ. EQ. 9' -8" MAX. R.O. SECTION SYMM. lialL OR TO H.S.S. F ICATION COMB. VERIFY THE H.S . & CORNS. WILL MI ROOF FRAMIN MEMBERS & CONNS. [16' -01 DETAIL a2 SIM. ABOVE DOOR EXIST. CONCRETE WALLS DETAIL a2 DETAIL a2 DETAIL (VIEWED FROM INSIDE) i " }� e 1.-0" MIN. INT0"0 HOLES FILLED i USE HIT —150 ADHESIVE. PLACE ALL—THREAD 90 TO FACE OF WALL w /HILTI 2.) DO liar SUBSTITUTE OTHER ADHESIVES FOR THE HILTI HIT HY -150 WITHOUT PRIOR WRC17EPI AUTHORIZATION FROM E.N.W. 3. HOLD H.S.S. " MAX. FROM WALL. 4. ANCHOR H THRU ANGLE TO BE 1 ' x 1 }�' HORIZ. SLOT CTR'D ON THE 4- DIM. 5. ANCHORS TO BE PLACED • 90' TO WALL 6. PROVIDE SPECIAL INSPECTION FOR ADHESIVE ANCHORS PER I.C.B.O. REPORT ER5193. 7. NO VERTICAL PANEL JOINTS ARE TO OCCUR WITHIN 24" OF Mai DOOR (ROUGH) OPENING. I. PER DTL a2 PER SECT. A -1 L's4x4x x 0' -4' DE H.S.S. w "0 ANCHORS SEE "NO #4' BELOW ELEV. A -1 TTYYPP i" x S.S. WIDTH + 1" re. w 2— "0 ALL— THREAD B ti" MIN. INTO "0 HO FILLED w/HIT —150 ADHESIVE. INSTALL & PROVIDE SPECIAL. INSPECTION PER I.C.B.O. ER5193 MAX. R.O. PER 9" SECT A -1 MIN. MAX. R.O. PER SECT A -1 w DETAIL a H.S.S. EA. SIDE OF OPNG. SEE SECT. A -1 FOR SIZE PAIR SECT. DETAIL a2 JIM NO R.O. 0 a2 SIM. DETAIL a3 TOP, BOT. & NEAR SIDE TYP. • ALL ANGLES 1�!! ltvtvlOCE CODE 0C1 o Cit11 e 8 I`p RECEIVEr SEP 3 0 2008 PERMIT CENTEI GENERAL NOTES ABBREVIATIONS PROJECT DATA DRAWING INDEX I. ALL. CONSTRUCTION SHALL COMPLY WITH THE CURRENT REGULATORY GODES FOR THE STATE OF WASHINGTON AND THE LOCAL JURISDICTIONS. SEE PROJECT DATA SECTION FOR CURRENT APPLICABLE CODES. 2. CONTRACTOR 15 TO VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC., AND NOTIFY THE DESIGNER OF ANY AND ALL. DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 3. CONTRACTOR SHALL VERIFY ALL. "BUILDING STANDARDS" WITH BUILDING LANDLORD PRIOR TO BEGINNING ANY WORK. HOW EVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS WITHOUT THE DESIGNER'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD THE DESIGNER HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 4. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS SHALL BE LEFT IN A GLEAN (BROOM) CONDITION AT ALL TIMES. 5. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 6. ALL OPERATIONS CONDUCED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASES, SMOKE, VIBRATION, HAZARD OF OTHER CAUSES. IN ADDITION, THE CONTRACTOR SHALL MINIMIZE DISRUPTIONS OF ADJACENT TENANTS DUE TO NOISE, ODOR, CORRIDOR FUMES OR VIBRATION. ALL COMMON LOBBY AND CORRIDOR SPACE SHALL BE KEPT CLEAR OF DUST, DEBRIS AND CONSTRUCTION MATERIALS AT ALL TIMES. 1. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 8. ALL DIMENSIONS ARE TO FACE OF GYPSUM W E ALL BOARD UNLESS OTHERWISE NOTED. a. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK IN THE SAME BUILDING. 10. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO PROPERLY COMPLETE THE WORK. II. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL. EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE .CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF HIS WORK. 12. THE CONTRACTOR WILL VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS OTHERWISE NOTED IN THE PLANS AND SPECIFICATIONS. 13. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND - WORKERS AT ALL TIMES. 14. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE JOB 15 IN PROGRESS AND UNTIL THE JOB IS COMPLETED. 15. ALL AFTER SHALL BE GUARANTEED FOR A PERIOD OF ONE (I) YEAR AFR COMPLETION, UNLESS OTHERWISE SPECIFIED AND SHALL BE 50 STA I tli IN CONTRACTOR'S W E RITN PROPOSAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS AND DISCREPANCIES ETC., MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (5) DAYS AFTER NOTICE IS GIVEN. 16. LATHING, PLASTER AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO THE CHAPTER 25 OF THE 2003 I .B.G. 17. ALL EXPOSED GYPSUM BOARD TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS. I. ALL GLASS AND GLAZING. SHALL COMPLY WITH THE 2003 I.B.G.. AND THE U.S. PRODUCT SAFETY COMMISSIONS: SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS. • Ict. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE SPECIFIC RATING. 20. EXIT SIGNS AND ILLUMINATION SHALL CONFORM TO THE 2003 I.B.G. CHAPTER 10 AND LOCAL FIRE MARSHAL REQUIREMENTS. 21. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 22. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATI WITH THE FIRE MARSHAL. CONTRACTOR TO SUPPLY FIRE EXTINGUISHERS AND CABINETS AS REQUIRED. 23. ELECTRICAL ROUGH -IN AND REFLECTED CEILING PLAN ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS SHOULD BE VERIFIED. 24. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED OR DISPENSED IN THIS OCCUPANCY PERMI MAY BE REQU RN N'F.P.A. STANDARD 30 AND THE CURRENT UNIFORM FIRE GODS. 25 INCLUDING CHRISTMAS TREES THAT WO� D END TO INCREASE REA E HE AND PANIC HAZARD SHALL BE MADE FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT SOLUTION OR PROCESS APPROVED BY THE COUNTY FIRE MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT. A. EXIT DOORS, EXIT LIGHTS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONGEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. B. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER THE 2003 I .B.G. 26. ALL LAY -IN ACOUSTICAL CEILING GRIDS SHALL BE INSTALLED AND SECURED PER THE 2003 I .B.G. STANDARDS FOR EARTHQUAKE ZONE D, ASME 0635, 0636. 21 PROVIDE OR MODIFY AS NEEDED SPRINKLER, ALARM AND SMOKE DETECTION SYSTEM PER APPLICABLE CODES, INCLUDING IF NECESSARY FIRE HORNS, STROBE LIGHTS, CONTROL PANEL CONNECTIONS, SMOKE DETECTORS, AUDIO VISUAL ALARMS. SUBMIT SHOP DRAWINGS TO THE FIRE MARSHAL FOR APPROVAL. s 28. TENANT TO PROVIDE AND INSTALL THE TELEPHONE AND DATA COMMUNICATION CABLING. CONTRACTOR TO COORDINATE SCHEDULING AND OTHER REQUIREMENTS WITH TENANT. 2Q. MEGHANIGAL SYSTEM: CONTRACTOR SHALL VERIFY AND PROVIDE A COMPLETE HVAG SYSTEM WHIGH CONFORMS TO THE OWNER'S HVAG SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ROOF PENETRATIONS AND PATCHING, ANY SCREENING OF ROOF - MOUNTED MEGHANIGAL UNIT REQUIRED BY GOVERNING JURISDICTION. 30. PROVIDE OR MODIFY AS NEEDED EMERGENCY LIGHTING. 31. ALL ITEMS MARKED *N.I .G.* ARE NOT PART OF THIS CONTRACT. 32. ABBREVIATIONS THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED 15 NOT INTENDED TO BE COMPLETE OR REPRESENTATIVE OF CONDITIONS OR MATERIALS ACTUALLY USED ON THE PROJECT. THE DESIGNER WILL DEFINE THE INTENT OF ANY IN QUESTION. 33. DO NOT SCALE DRAWINGS. IF A DIMENSION DISGREPENGY IS NOTED, CONTACT DESIGNER. 34. IF BUILDING STANDARDS HAVE NOT BEEN ESTABLISHED OR HAVE BEEN ESTABLISHED OR HAVE BEEN CHANGED FOR DOORS, RECITES, HARDWARE , DOOR AND RECITE FRAMES OR OTHER STANDARD DETAILS, THEN CONTRACTOR MUST VERIFY WITH DESIGNER AND OWNER PRIOR TO CONSTRUCTION. 35. ALL ACCESSIBILITY SIGNAGE SHALL COMPLY WITH REQUIREMENTS FOR IGG /ANSI A111.1 -2003 SECTION 703 - SIGNS FOR VISUAL CHARACTERS, TACTILE CHARACTERS, BRAILLE, PICTOGRAMS, AND SYMBOLS. THESE SHALL BE PROVIDED FOR ROOM IDENTIFICATIONS, WAY - FINDING AND EXITING ACCOUS. ACOUSTIC /ACOUSTICAL LAM. LAMINATED /LAMINATE ACT. ACOUSTICAL TILE LAV. LAVATORY ADJ. ADJUST /ADJUSTABLE L. LENGTH A.F.F. ABOVE FINISHED FLOOR LTG. LIGHTING APPROX. APPROXIMATELY LT. LIGHT ARCH. ARCHITECTURAL LG. /L. LONG BLK. BLOCK /BLOCKING MAT MATERIAL T. BD. BOARD BLDGJBLD. BUILDING MAX. MAXIMUM B/5 BUILDING STANDARD MFG. MANUFACTURER MECH. MEGHANIGAL GAB. CABINET MED. MEDIUM CLG. /GLDG. CEILING MIN. MINIMUM GL OR G CENTER LINE MIN. MINIMUM GLKG. CAULKING M15G. MISCELLANEOUS COL. COLUMN MTD. MOUNTED CONT. CONTINUOUS MTL. METAL GONG. CONCRETE MW. MICROWAVE CONST. CONSTRUCTION CONTR. CONTRACTOR N. NORTH CPT. CARPET N.I.G. NOT IN CONTRACT G.W. GOLD WATER N.T.S. NOT TO SCALE NO. NUMBER D. DEEP DEPT. DEPARTMENT OFF. OFFICE DET. DETAIL O.G. ON CENTER DIAL. DIAGONAL O.F. OWNER FURNISHED DIA. DIAMETER o.F.G.I. CONTRACTOR INSTALLED DIM. DIMENSION O.F.O.I. OWNER FURNISHED DBL. DOUBLE 'OWNER INSTALLED DWG. DRAWING D.F. DRINKING FOUNTAIN PNL. :PANEL (INW DIFF. DIFUSSER PT. PAINT (EP) D.N. - DOWN PART. PARTITION P.P.L. POLISHED PLATE GLASS E. EAST PL. PLATE EA. EACH P. LAM. PLASTIC LAMINATE ELEV. ELEVATION (BLDG.)/ PLY. PLYWOOD ELEC. ELECTRICAL EMER. EMERGENCY Q.T. QUARRY TILE QTY. QUANTITY EXT. EXTERIOR EQ. EQUAL R.B. RUBBER BASE EQPT. EQUIPMENT EXIST. EXISTING R. RISER RANGE RAP. RADIUS REF. REFERENCE F.1.0 FURNISHED 4 READ. REQUIRED INSTALLED BY OTHER REV. REVISED /REVISION F.A. FIRE ALARM R.O. ROUGH OPENING F.E. FIRE EXTINGUISHER RM. ROOM F.E.C. FIRE EXTINGUISHER CABINET FIN. FINISH 5. STAIR FIXT. FIXTURE SECT. SECTION F.D. FLOOR DRAIN SHT. SHEET FLR. FLOOR SIM. SIMILAR F.O.1.G. FURNISHED BY OTHER SPEC. SPECIFICATIONS/ INSTALLED BY SPECIFIED CONTRACTOR 5. SOUTH FT. FOOT OR FEET STL. STEEL 55T. STAINLESS "STEEL GA. GAUGE STD. STANDARD GALV. GALVANIZED STOR. STORAGE GL. GLASS /GLAZING /GLAZED STRUG. STRUCTURAL G.W.B. GYPSUM WALL BOARD SUSP. SUSPEND /SUSPENDED GYP. GYPSUM 5W. SWITCH H. HIGH HCP. HANDGAP TEL TELEPHONE HD.WD. HARD W OOD TEMP. T HD. HEAVY DUTY TYP. TYPICAL ' HM.- - HOLLOW METAL HT. y HEIGI ONTAL "" U'L' LABORATORY . U.P.G. UNIVERSAL PLUMBING HVAG. HEATING, VENTALATING CODE AIR CONDITIONING H.W. HOT WATER VOL. VOLUME VAR. VARIABLE/VARIES .B.G. NTERNATIONAL BUILDING Y.G.T. VINYL COMPOSITION TILE CODE VERT. VERTICALNERTIGALLY NW. NGANDESGENT V.P. VENEER PLASTIC NGL. NGLUDE NFO. NFORMATION W.B. WOOD BASE NSUL. NSULATE (D)(ING) W:G. WALL COVERING NTR. NTERIOR WD. WOOD INN WEIGHT JAN. JANITOR yI DE J B JOINT JUNCTION VITH CATER HEATER WEIGHT PROJECT ADDRESS: 1224 ANDOVER PARK EAST TUKWILA, WA GOVERNING CODE: 2006 I.B.G. (STATE OF WASHINGTON AMENDMENTS) U5E ZONE: - OCCUPANCY: 5/S -2 CONSTRUCTION TYPE: 3 -5 - (FULLY- SPRINKLERED) ENERGY CODE: 2003 WASHINGTON STATE ENERGY GORE (W/ SEATTLE AMENDMENTS FOR C ITY OF SEATTLE) ACCESS GORE: I GG /ANSI A117.1 -2003 PLUMBING CODE: 2006 U.P.G. CONTRACTOR: TO BE DETERMINED PRIOR TO PERMIT ISSUANCE MEGHANIGAL: BIDDER DESIGN (UNDER SEPARATE PERMIT) ELECTRICAL: BIDDER DESIGN (UNDER SEPARATE PERMIT) SPRINKLER SYSTEM: BIDDER DESIGN (UNDER SEPARATE PERMIT) . SITE AREA: 44,253 SF - 1.02 ACRES NORTH OFFICE AREA - EXISTING: 1,510 5F (SUITE 1222) SOUTH OFFICE AREA- REMODEL: 2,660 5F (SUITE 1224) WAREHOUSE AREA- EXISTING: 20,0'13 5F TI COVER SHEET AI.O BUILDING PLAN AND WINDOW LOCATION PLAN WITH ENGINEER'S PACKAGE /CALCULATIONS •- LEGAL DESCRIPTION /PARCEL MAP TAX PARCEL NUMBER: 3523044011 ft LEGAL DESCRIPTION: t 13023040 ;Di PORTION OF GL.I OF SECTION 35 -23 -05 OAF- BEGINNING 36'231•t9.09a AT THE NORTHEAST CORNER OF THE SD SECTION 35 THEN NORTH 87 -44 -08 WEST ALONG THE NORTH LINE OF € 35230190/6 S17 SECTION 44'1.48 FEET THEN SOUTH OI -51 -3a WEST 512.21 FEET THEN SOUTH 88 -OS -21 EAST 30 F EET TO THE POINT OF BEGINNING THEN CONTINUE SOUTH 88 -OS -21 EAST 253 FEET THEN SOUTH OI -51 -3a WEST 3523049 7 112.83 FEET THEN NORTH 88 -OS -21 WEST 253 FEET THEN NORTH 0I-3q-3q EAST 172.83 FEET TO THE PROINT OF BEGINNING. f" a = ja�� s,,13u Tukwila 3023049074 3,2ao,t5�tJr / -. - -• . a., - - eso 44I 352304084 :k',230,10-060 :3623049 )06 i ? ,, ,, «smy , o ®s tt . .. � �` -` SITE PLAN SCALE 1 " -30' _ ---� �� '' ��I pL NEC telk ' OCC 0 9 20th$ . / ... -- ' C t 'YIA 04 �, q � G N • , �'. d (� r � I O o I3 ssub ci �' fS tO � 0v ru;tio O f 0 "`3 flO %t ats Ot'� Q a s 'ty °. �z1 provat v vw.� ;'i�lt1 CLAY and t�t� is �nC t . bJ$ L , / ` - r EXIT EXIT n r VICINITY MAP STE 1222 . EXISTING TRUCK WELL o a WAREHOUr E 20 043/500 =41 OGG. p r re'' tl�� ��ita'atior� w t 0 rf n � , ::171 L Renton -T_ _ _ Y4a { o appr� � ` -- + " ;; • f---•• $ • ` Triland Dr -� I ! " ~: fir, Y _, °" W - . " ' Q F i � 1224 Andover i '' s -180th _ 1 ' Ordlia St d •° Park E, IS ' Date: City of Tukwila BJII DING DIVISION W 0 , ,,,,...•..... r' -- -~ R ��(i�10i` i S sc o pe t0 th. s hall - rovai of ch �BS Without p rio r a o f d o r k piv isi on B Sub n T :19:1Cni:111,..9 la u i ld in g ne plan m itta a • NO o . EXI5T1N6 WEU - - 4 - pk ` S `n S 182nd 1 y 3 ' W ;=- _ __ ( /' .. ' 1 =r • + i' W C. / } r r ` { + r ' a ;. 1 ' s 188tH St ' C- (;Iarirr - St -- St �' a -6 i J e a- _t____-__.y, (111) - s -184th St! 1 1 .� -0� 11111 CI Z a y ; N � i nn Ce � 1 � Q w f ees . • e will require n ade additi P i - . 'rmifilliii N n - : " - r I- - - ► 1 �, c� �I4El '. NEW WINDOW LOCATION 6xlBnNb orrice) _ _ TE PERIIIIT R EQUI R E D FO SEPARA Mechanical ( Electrical LeiPlumbing t.J Gas Piping City of Tukwila BUILDING DIVISION NO NO CHA GHAN6E5 oo• OCC. 1610/100. w = 2660 5F (OFFICE TI) CONTRACT T1+19 - 266OIIOO .Al n - - - IIIIII�� EXIT EXIT ONE VN/AY < . Y1, � fr Y fr 7 t 1b0 8 . LI 4 1 SHEET NO. REGISTRATION 8694 PROJECT NAME DESIGN TEAM PROJECT NO.: 08.132 PRINCIPAL: VS DRAWN BY: EC CHECKED BY: CK PROJECT CONSULTANTS CON planning interiors architecture DESIG 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425 - 670 -6706 F: 425 - 774 -8219 SHEET TITLE COVER SHEET DAVNA STATE OF WASHNGTON EXF': •03 =03=09 CASCADE YARNS EXTERIOR WINDOWS ANDOVER PARK EAST TENANT IMPROVEMENT SUITE 122 1224 ANDOVER PARK EAST TUKWILA, WASHINGTON ISSUED /REVISIONS 9 -30 -08 ISSUED FOR PERMIT RECENT SEP 3 0 2006 PERMIT CENT& T1.0 RELITE LOCATION IN OFFICE NTS RELITE LOCATION IN NO. WALL NTS RELITE LOCATION IN NO. WALL NTS EXISTING WINDOW LOCATIONS FOR REFERENCE B/S STOREFRONTS NTS NEW LOCATION FOR STOREFRONT WINDOWS EXISTING STOREFRONT TO MATCH W/ CURRENT CODE COMPLIANT STOREFRONT DEMOLITION NOTES SCALE :I /8 " =1' -m" WHERE DEMOLITION OCCURS, ALL REMAINING WALLS ARE TO BE PATCHED, SANDED SMOOTH AND PREPARED FOR FINISHING AS REQUIRED. REMOVE EXISTING FLOOR FINISHES. PATCH AND PREPARE FLOORS AS REQUIRED FOR SMOOTH, LEVEL FINISH. ALL EXISTING WALL FINISHES TO BE REMOVED. WALLS ARE TO BE PATCHED, SANDED SMOOTH AND PREPARED FOR NEW FINISHES AS REQUIRED. WHERE NEW PARTITION MEETS EXISTING FURRED COLUMN OR GORE WALL, REMOVE CORNER BEAD, ALIGN, TAPE AND SPACKLE NEW PARTITION TO EXISTING GYPSUM BOARD. ALL CONSTRUCTION TO REMAIN AND AFFECTED BY DEMOLITION SHALL BE PATCHED AND SPAGKLED AND BE PROPERLY MEMBERED AND ALIGNED 50 AS TO LEAVE NO EVIDENCE OF PATCHING OR REPAIRS. EXISTING ELECTRICAL AND TELEPHONE OUTLETS LOCATED ON DEMOLISHED WALLS ARE TO BE REMOVED INCLUDING CONDUIT AND WIRING BACK TO JUNCTION BOX. LOCATIONS ARE TO BE PATCHED AND REPAIRED TO BE FLUSH WITH. ADJACENT WALL SURFACE. ALL EXISTING CONSTRUCTION WHERE INDICATED INCLUDING ELECTRICAL, TELEPHONE, PLUMBING AND MECHANICAL DEVICES NOT OTHERWISE INDICATED ON THESE CONSTRUCTION DRAWINGS SHALL BE REMOVED IN A CAREFUL MANNER SO AS NOT TO DAMAGE ADJOINING CONSTRUCTION. PARTITION NOTES CONTRACTOR TO VERIFY ALL DIMENSIONS. ALL DISCREPANCIES MUST BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DIRECTION. ALL PARTITIONS, UNLESS OTHERWISE NOTED, SHALL BE CONSTRUCTED WITH METAL STUDS AT 24" O.G. WITH 5 /S" TYPE 'X' GYPSUM WALLBOARD EACH 510E. THERE SHALL BE NO EXPOSED PIPE, CONDUIT, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONGEALED OR FURRED AND FINISHED, UNLESS OTHERWISE NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS. OFFSET STUDS, WHERE REQUIRED, SO THAT FINISHED PARTITION SURFACE WILL BE FLUSH, UNLESS OTHERWISE NOTED. PROVIDE FURRING AT EXISTING PARTITIONS AS REQUIRED TO INSTALL ELECTRICAL ITEMS AS INDICATED ON THE DRAWINGS. DOOR AND CASED OPENINGS WITHOUT LOCATION DIMENSIONS ARE TO BE SIX INCHES FROM FACE AT HINGE SIDE OF DOOR TO ADJACENT PARTITIONS. CONTRACTOR TO REMOVE ANY WALL MOUNTED FIXTURES/FURNITURE PRIOR TO INSTALLATION OF NEW EXTERIOR STOREFRONT OPENING. VERIFY W/ TENANT PRIOR TO REMOVAL FOR RECONFIGURATION DETAILS. EXISTING WAREWOUSE 1 101 1 E O FF IIC E. 1 102 1 1 103 1 e . �r cn 0 EXISTING OFFICE KEY NOTES EXISTING OFFICE 1 109 PARTITION LEGEND O 0 EXISTING OFFICE 1 104 1 EXISTING EXIST BRE AK 1 107 I I L J BUILDING PLAN AND WINDOW LOCATION PLAN EXISTING PARTITION TO REMAIN. B/5 PARTIAL HEIGHT DOUBLE SAFETY GLASS RELITE —MATCH EXISTING B/5 FRAME COLOR AND TYPE OF STOREFRONT MULLIONS. SEE PICTURES AND VERIFY ON SITE CONDITIONS W/ BLD. OWNER/TENANT. 1. PROVIDE B/5 EXTERIOR RELITES WHIGH MEET CURRENT ENERGY CODES FOR LOW E, ARGON GAS FILLED DUAL PANE STOREFRONT RELITES. ALIGN MULLION W/ EXISTING OFFICE WALL AS SHOWN. SEE DETAIL I PROVIDED FOR MULLION TO WALL CONDITIONS. (BID ALT. PROVIDE OPERABLE PANEL IN RELITE) GLAZING EXISTING WALL: 5/8" G.W.B. EA. SIDE OF METAL STUD. "J" BEAD AT EA. END. SILL LINE PAINT EXPOSED STUD BLACK 2" WIDE BLACK GASKETING MULLION WALL SECTION AT MULLION SCALE: N.T.S. U L--J EX X 1051 COD COMPLIAN C WOO 0 0 0 9 20 Tukwila ILDING.. 8 C planning DESIG 22002 - 64th Avenue W., Suite 2C Mountlake Terrace, WA 98043 T: 425 - 670 -6706 F: 425 - 774 -8219 REGISTRATION 8694 PROJECT NAME CASCADE YARNS EXTERIOR WINDOWS ANDOVER PARK EAST TENANT IMPROVEMENT SUITE 1224 1224 ANDOVER PARK EAST TUKWILA, WASHINGTON DESIGN TEAM PROJECT NO.: 08.132 PRINCIPAL: VS DRAWN BY: VSS CHECKED BY: CK ISSUED /REVISIONS 9 -30 -08 ISSUED FOR PERMIT PROJECT CONSULTANTS SHEET TITLE BUILDING PLAN WINDOW LOCATION SEP 3 0 AKA PERMIT CENTEI SHEET NO. NELL interiors \ architecture DAVNA WILLIAMS STATE OF WASI-NGTON EXP. 03 -03-09 A1.0