Loading...
HomeMy WebLinkAboutPermit D08-459 - LA PANZANELLA - STORAGE RACKSLA PANZANELLA 18475 OLYMPIC AV S D08 -459 Parcel No.: 7888900111 Address: 18475 OLYMPIC AV S TUKW Suite No: Tenant: Name: LA PANZANELLA Address: 18475 OLYMPIC AV S , TUKWILA WA Owner: Name: RRP LA PANZANELLA LLC Address: 1808 PARKSIDE DR E , SEATTLE WA 98112 Phone: Contact Person: Name: DAVID KEHLE Address: 1916 BONAR DR SW , SEATTLE WA 98116 Phone: 206 433 -8997 Contractor: Name: OWNER AFFIDAVIT IN FILE Address: Phone: Contractor License No: Cit* Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DESCRIPTION OF WORK: INSTALL STEEL UPRIGHT RACKING PER PLAN AND ENGINEERING Value of Construction: $0.00 Fees Collected: $299.03 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: doc: IBC -10/06 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D08 -459 Issue Date: 07/08/2009 Permit Expires On: 01/04/2010 Expiration Date: D08 -459 Printed: 07 -08 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby c gave The gr construe Signature: Print Name: doc: IBC -10/06 City d�Tukwila � Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N e� Tfy that I ha this work will ting of this p : ion o the • erfo e read and examined this permit and know the same to be true and correct. All provisions of law and ordinances e complied with, whether specified herein or not. d • :: s not • esume to Ove authority to violate or cancel the provisions of any other state or local laws regulating ce o k: I am alu horized to sign and obtain this development permit. Date: 7/e q Permit Number: D08 - 459 Issue Date: 07/08/2009 Permit Expires On: 01/04/2010 Private: Public: Profit: N Non - Profit: N Private: Public: ( Date: Or /a/o 9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -459 Printed: 07 -08 -2009 Parcel No.: 7888900111 Address: 18475 OLYMPIC AV S TUKW Suite No: Tenant: LA PANZANELLA 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -459 ISSUED 10/08/2008 07/08/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final' report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following :concerns: 11: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so D08 -459 Printed: 07 -08 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (1FC Chapter 10) 19: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 24: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, doc: Cond -10/06 D08 -459 Printed: 07 -08 -2009 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 25: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 26: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 27: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: Clearance between ignition sources, such as light fixtures, heaters, and flame - producing devices, and combustible storage shall be maintained in an approved manner. (IFC 305.1) 32: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinlder at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 33: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 34: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 36: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 37: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 38: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D08 -459 Printed: 07 -08 -2009 doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** D08 -459 Printed: 07 -08 -2009 • • City of Tukwila I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be-eom • lied with, whether specified herein or not. The gran constru Signature: Print Name: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Rin of this pe ion or the pe 't does not pre time to give authority to violate or cancel the provision of any other work or local laws regulating rmance of ' ork. Date: / doc: Cond -10/06 D08 -459 Printed: 07 -08 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap://www.cl tuhvila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Building Permit No. Poq — 1 10 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) SITE LOCATION King Co Assessor's Tax No.: lb 5 - 01 11 Site Address: I 54 j . (rrfiG /Aft Tenant Name: 14 I H e Property Owners Name: Value Ri o I /o 1.4 V 14-ei Mailing Address: lbetici eltiftvc. ./Ak. licumw City Suite Number: Floor. ` New Tenant: ❑ Yes 40c.No CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 10 KOL Mailing Address: Ivl E -Mail Address:Aey I-e 2 d kel � e Uyrdt . £D 4t. GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mee- Contact Person: E -Mail Address: Contractor Registration Number: Company Name: o to GIE i , 1.V.611 Mailing Address: W/ rtat Contact Person: avi0 E -Mail Address: 4 K2 1 1 e k i £V'4t ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: 12 `r 1. �.t`k 4 U '..I€ ILi4 Mailing Address: 2 V1 Contact Person: 4 M41 I') Wt E -Mail Address: Q:UpplicatiomfYmnn- Application On Lind -2006 - Pamit Appli®rian.doe Revised: 9.2006 bh Day Telephone: "t t ,, -- t'"` - tAh. eMI hvsttrE City Stare ����..yy Zip Fax Number: '/x.10 4440 " P &o Mailing Address: City State Day Telephone: Fax Number. Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record 605itrir wo. t City Sram�, /� Zip Day Telephone. Fax Number:19 ' ' bSta I City �y Day Telephone: Number. 6.1D - State ZiP 1170+ ZIP Page 1 of6 • BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Q :UpplicationsaramsAppliouoa1 On Line U-2006 - P m t Appliration.doc Rcvix t: 9-2306 bh S Existing Buildin • Valuation: S 14t W c 4 Will there be new rack storage? NI Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: I Will there be a change in use? ❑ Yes 154 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: `e Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor ,u i 4 , XV I �/ y i E/'r 2 Floor 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck • BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): S Scope of Work (please provide detailed information): Q :UpplicationsaramsAppliouoa1 On Line U-2006 - P m t Appliration.doc Rcvix t: 9-2306 bh S Existing Buildin • Valuation: S 14t W c 4 Will there be new rack storage? NI Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: I Will there be a change in use? ❑ Yes 154 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: `e Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 I Date Application Accepted 1 O I O V I o$ Date Application Expires: � Ia I t1 Staff Initials: PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. BUILDING OWi Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: /� Print Name: 44V t7 h '66 AGENT: Mailing Address: 4 I o 9 Q: \Applications \Fotms-Applicationa On lircV -2006. Permit Applicmioc.doc Reviscd: 9 -2006 bh Date: I`-' 1 Day Telephon WO— j State egFlika Page 6 of 6 Parcel No.: 7888900111 Address: 18475 OLYMPIC AV S TUKW Suite No: Applicant: LA PANZANELLA Receipt No.: R09 - 01052 Initials: User ID: LAW 1632 Payee: RON HACKER TRANSACTION LIST: Type Method Descriptio Amount Payment Cash Authorization No. ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT 183.00 Account Code Current Pmts 000/322.100 178.50 640.237.114 4.50 Total: $183.00 0918901-1 0125 07/0R/2009 001 101 DCD Pern F'lu_. - General Fund $176.50 Permit Number: D08 -459 Status: APPROVED Applied Date: 10/08/2008 Issue Date: Payment Amount: $183.00 Payment Date: 07/08/2009 01:54 PM Balance: $0.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -08 -2009 Receipt No.: R08 - 03475 Payee: DAVID E. KEHLE ARCHITECT ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7888900111 Permit Number: D08 -459 Address: 18475 OLYMPIC AV S TUKW Status: PENDING Suite No: Applied Date: 10/08/2008 Applicant: LA PANZANELLA Issue Date: Initials: JEM Payment Date: 10/08/2008 02:05 PM User ID: 1165 Balance: $183.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 18423 116.03 Account Code Current Pmts 000/345.830 116.03 Total: $116.03 Payment Amount: $116.03 dot: Receiot -06 Printed: 10 -08 -2008 Project: L\ Pa ti7— An L.1. A Type of Inspection: Fl N A L Address: 1 8 u - 7 5 0 L t-(na o f (° Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: L12:6- 11, - L i t (9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit flog - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R-- 6300 Southcenter Blvd., #100 Tukwila WA 98188 (206)431 -36P Approved per applicable codes. Corrections required prior to approval. COMMENTS: { / I -Pc_ 7 a-►..r A A ❑ $60.00 REINSPECTION FEE REQ IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: Type of Inspection: /A/4L Addr / /75 i/ 'v ,9 » S U . $gQe 1 -i1 ve:- 7 JA ~ A-A c a f l! '' LT) ,/ j 4/1/4 ( , (9 (--; '44 ( -e ild , - , Phon c No: 3 ,Ae 3�v<3 S` A4.1 n�` r , P ey D^ 1�, tic r Le. re( k 0 I [I Project: / 4-4 P a l N 2 4 A I r a 4 Type of Inspection: /A/4L Addr / /75 i/ 'v ,9 » S to Called: Special Instructions: Date r d: // t� � n p.m. Requester: Phon c No: INSPECTION NO. Approved per applicable codes. INSPECTION RECORD Retain a copy with permit &C.5 4 9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Corrections required prior to approval. ❑ $60.00 REINSPECTION FEE REQUIREb. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspect r: Date: Receipt No.: IDate: COMMENTS: vj� — h�E /j `e-4-47 ` i Type Ins Q! I / � / � � v B'z.c.ii+ -' c_ /7 607 .S'rhe cif /„v/ 7---.5 Q /5 A C --,4) ,A, eyed- evAc. Special In tr tions: cl,e) ,i,e/ o /e- 7 D 4;f-j'; / /'L- ; , !,, '9 / Date Wanted: 7 31 4 2) (�..J / c - e .S - `' -/i.s Ar G,, 7 ...��� r-t-- srh ®,Ll../.i. Phone N — 3(8. 2,410 Projgct: \/ Z e l l ,� (, P� I Type Ins Q! I � c,�� Address: C Date Called: Special In tr tions: cl,e) ,i,e/ o /e- 7 Date Wanted: 7 31 a.m. Requester: Phone N — 3(8. 2,410 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 EI Approved per applicable codes. Corrections required prior to approval. 2' Inspecto REINSPECTION FEE R UIRE Prior to inspection, fp4 must be 6300 Southcenter Blvd., " I • 100. Call to schedule reinspection. No.: INSPECTION RECORD Retain a copy with permit Date: 7- 3/- 'Date: flog -A 5ei PERMIT NO. (206)431- Project: 44 ('s*, 7,40.7 X14,, Type of Inspection: ie yd w is 4fra.,.1 Address: J 7,1 Suite #: c3.4.414 G i40 I. i /Sar, Contact .Person: - fi e. re `r4.( Special Instructions: Occupancy Type: Phone, No.: .hoc • -. 76 • 3" f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: _ Pre -Fire: Permits: Occupancy Type: 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT .09P- 'i.5 d9 - PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 =575 -4407 Approved per applicable codes. I - I Corrections required prior to approval. COMMENTS: g_.S 21 b . l :. I Inspector: • Date: 8Ic/p Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Calk to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 OTTO ROSENAU & ASSOCIATES, INC. • Geotechnical Engineering, Construction Inspection & Materials Testing Report Number: 103965 Description: Anchor Bolts CONSTRUCTION INSPECTION REPORT Project: La Panzanella Bakery Permit Number: D08 -459 Address: 18475 Olympic Ave S, Tukwila Job Number. 08 -0620 Client: La Panzanella Client Address: 612 S Alaska St, Seattle, WA 98108 Inspector and Date Remarks Darren Reid Performed inspection of previously placed Simpson Strong Bolts at metal shelving x 4 places per ICC 8/17/2009 ES ESR 1771. Torque testing was done on a minimum of 80% of the bolts and all bolts tested met 60 foot -pound torque required per Simpson specifications. Conforms Copies to: X Client Contractor Architect X Building Dept. Technical Responsibility: X Engineer RED' ` c_D 'AUG 3 1 2009 CG,rru !ry DEVELOF'w1ENT / //All f er H 't , Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725 -4600 or 1- 888 - OTTO -4-US — Fax (206) 723 -2221 Form No.: ADMIN -63 -01 (Rev 05/03) OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Report Number: 103961 Description: Anchor Bolts CONSTRUCTION INSPECTION REPORT Project: La Panzanella Bakery Permit Number: D08 -297 Address: 18475 Olympic Ave S, Tukwila Job Number: 08 -0620 Client: La Panzanella Client Address: 612 S Alaska St, Seattle, WA 98108 Inspector and Date Remarks Darren Reid On site for wedge anchor torque test. Contractor not on site, bolts not tight. Cancel without notice. 8/11/2009 Copies to: X Client Contractor Architect X Building Dept. Technical Responsibility: X Engineer zrri 'ter C H n n, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 - 4600 or 1 888 - OTTO - 4 - US - Fax (206) 723 - 2221 Form No.: ADMIN -63 -01 (Rev 05/03) FP -1 I " MATTHEW 99E I % � A9 NOTED FIRE SPRINKLER SYSTEM =arra* wAyeousa EWE MY krA - SEC 11•021, • PM MAY talCO I Are a I SimplexGrierrell Security re WY HO SEM 206,11-400 SERVICE: 208411-1sco °M II 4 V; LA PANZANELLA SOS OLYWC AVENUE ......... WA 95113 .0,...,10: FAX: 200.1.1500 AMP= `• Z 1! 1 1 g 7! X II 2 I. 1 11 ' .1' I 1 . • FILE COPY - Penult No. Plan review approval is subject to error* nr4 nrnte-elfulr' 0117-c Arrrovat of 111 11s! I ii J i TIT ! ill fit,. _J 1 P r 11 IF ITT ir 2 r9IP in !IC! 9!=: !p 1' Fill it Ii , pril ;Al it!! Ft I41 FP iiI fij jfj Er 11 1fil liii Pel e.,00 "e cpeo: o • a" 9 O 2 ° CIL o cJ; o icr ® o o _jj . . 1 ) Q ° 0 0 ! I 0 a 14, 0 10 a 0 • 0. • 6 1 . ti• 0 .!P . fle — I EWE WED FOR 1 ODE COMIN .I. 7 __ A a r . I er I . I , ,, i:.00 . itYof 'lbw a IF C - 1 • . c_ z r.s,) o rCT3 1 411/ 11 III [i .11! lei II ER fflI tri1 TI 11 1 1 I 14 141: I t I I El! 1110 W ap! 1 I ;141 Fr Ill ° i/: . : 0 O.; tj. 0 j1.0 .. 0, 9P 'Dan Packaging material will consist of the follow types: rPVipy, Plastic bags (2000 count) in corrugated boxes Cardboard boxes (400count) in corrugated boxes Corrugated boxes bundled in 375 to 500count Finished goods - Cracker in poly over wrap — in a plastic bag box (12count) Poly over wrap — 501b rolls - 27 rolls per pallet REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 6 2009 City of Tukwila BUILDING DIVISION CORRECTION LTR #,1__. X08 �S9 permit No co — in a corrugated RECEIVED OCT 232008 PERMIT CENTER 10/22/2008 09:25 BY G. OHANIAN DATE . 19 -9 -08 SUBJECT COLUMN ANALYSIS 3" 100% LOAD t L.L.= 2 x 3 . 5 x =3.5 K 2 coy. COMBINED STRESS RATIO - +7-6- = 1<1.33 P M 7 BASE PLATE ANCH. TENSION ANCHOR SHEAR (2) -1/2 "0 HILTI KB -TZ ANCHORS ESR -1917 OR APPROVED EQUAL SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 7/16 "0 RIVET A =.1 Fy = 79 1(51 Va = .1x79x.4 = 3 K Ma =3Kx4 "x1.33 =16 K CONN. 818 -240 - 3813 Fy =55 KSI A= .8 S r =1.2 r =1.1 13— (3.7x3 ") _ .31K 6 " = x =. 14K RAdK DEOIcN Sc ENdINEERINd d0. 412 WE T BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 W =.2 = 3.7 K 3 PIN CONN. {CI 90x1.7_128 r 1.2 = - =40 Y • Max =Sx •Fb =26 "K RACK DESIGN PAGE 02/02 8.5 'K Fe= 4 - 1 --a- 6 - - 18 r F F =18 P =F xA= 14 P Pn _7K O 1.92 - 3 SHEET NO. 3 JOB NO RD -13692 7 3 /4 "xS "x3/8" BASE PLATE RECEIVEr OCT 232008 PERMIT CENTEI g� ' G. OHANIAN DATE 19 -9 -0 8 SUBJECT. STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: LAPANZAN ELLA 18475 OLYMPIC AVE. TUKWILLA, WA. 98188 STORAGE RACKS CAPACITY: 3500 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -13692 RACK DEOIGN & EN(INEERING CO. 412 WEPT BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 6 2009 City of Tukwila BUILDING DIVISION PER IBC 2006 EDITION EXPIRES 12 -26 -09 SHEET NO. 1 . RD -13692 JOB NO. Peril* NO COpY RECEIVED CITY OF TUKWLA OCT 0 8 2008 PERMIT CENTER PO 1-19 BY. G. OHANIAN DATE 19 -9 -08 SUBJECT 144" & 94" 5 1/8" BEAM M= 144 "x2K .36•K 8 S R — 33 = 1.09 <1.25 FRONT VIEW 0— 5xWxL3 =.69 "< 144 = .80" 384x1 xE 180 SEISMIC DESIGN S v_ — Rx 1.4 WORK NG STRESS 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED S =. (USGS WEBSITE, SITE CLASS "0 ") W =D.L.+ 3 L.L. LOAD PER COLUMN L.L. = 2 x x3.5K =2.3K 3 2cm W =.2 D.L 2.3L 2.5 K V = .95x1x2.5 = .29K LONGIT. 6x1.4 = .95x1x2.5 43K V TRANS. 4x1.4 • RACK DESIIGN & ENGINEERING CO. 412 WEST BROADWAY, BUTTE #204 dLENDALE, CIA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 3500 #1 LEVEL +25% IMPACT LOAD 2000 #1 BEAM I x =3.36 S, =1.25 FY = 55 KSI. IBC 2006 ASCE 7 -05 (SEC 15.5.3), RMI SPECS. LONGIT. SEISMIC .29 K SIDE VIEW 4" BEAM M= 94 "x2 K = 23.K 8 S R = 33 K= .71 <.85 A- 5xWxL3 =.35 "< 94 = xE 180 13 "K SHEET NO. 2 JOB NO.. RD - 13692 I =1.84 S=.85 FY =55 1(51. B y • G. OHANIAN DATE. 19 -9 -08 SUBJECT. COLUMN ANALYSIS x- 100% LOAD 3' t =.os L.L.= 2x3 =3.5 K 2 COL COMBINED STRESS RATIO P +M — 3.7 +13 = 1 <1.33 P M ox 7 26 MOMENT AT BEAM CONNECTION 7/16 "O RIVET A =.1 Fy = 79 KSI Va = .1 x79x.4 = 3 K Ma =3 "x1.33 = 16 "K CONN. Fy =55 KSi A =.8 S =.8 r =1.2 r =1.1 BASE PLATE ANCH. TENSION = 13— (3 ") — .31K ANCHOR SHEAR = •2 —, 14 K 2 (2) -1/2 "o HILT! KB —TZ ANCHORS ESR -1917 OR APPROVED EQUAL RACK DEMON & ENGINEERING CO. 412 WE BROADWAY. QUITE #204 L ENDALE, dA. 91204 TEL:(818)240 -3810 FAX :(818)240 -3813 W =.2 D. L 3.5 3.7 K 3 PIN CONN. ICI = 90x1.7 _ 128 r 1.2 KI = � =40 r Max =Sx •Fb =26 'K 8.5 'K 2 Fe= 1T F =F 18 KSI P =F„ xA= 14 P = n — P a 1.92 — 3.7 K 13j SHEET NO. 3 RD - 13692 JOB NO. 7 3/4 "x5 "x3/8" BASE PLATE • ' BY ' G. OHANIAN DATE 19 - - 08 SUBJECT OVERTURNING TOP LEVEL LOADING (100% LOAD) M OT = •43 "x.5x1.15 = 72"K MR = 2.5 K x44" = 110 "K NO UPLIFT LOAD TO DIAGONAL P = .43 K x2x 5 8 = 1.1 K 44 FY =50 KSI A =.31 r, =.48 Q =.74 L= 58" CHECK WELDS Fa= 10.6 KSI P = 3.3 K 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K CHECK SLAB 3700 0' 1000 — 3. 3.7x144=533 °" Viii=23" M= ( ) x 1000x 2 x12=1500 "# S 12x5 = 50 6 1500 = 30 < 1.6 200 =80 50 RACK DEMON & ENGINEERING CO. 412 WE BROADWAY, f UITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 L.L. = 1x3.5K= 1.8K 2 coL W= .2 +1.8 = 2K V _ .95x1 x2 =. 33K TRANS. 4x1.4 BOTH SIDES TYP. x x t =.07" 3700 6 M = .33 "= 96 " K MR =2 Kx44" = 88 " K UPLIFT = 9 4 = . 18 K SHEET NO 4 RD -13692 JOB NO. 5" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL COMMUNITY DEVELOP A.A.R. Testing Lab Inc. P.O. Box 2523 Redmond, WA 98073 425 881 -5812 425 586 -5538 FAX Agra Earth•& Environmental 11335 NE. 122nd Way #100 Kirkland, WA 98034-6918 425 820 -4669 Ext. 3095 425 821 -3914 FAX Anvil Corporation 1675 W. Baker View Rd Bellingham, WA 98226 360 671 -1450 360 821 -391.4 FAX Cascade Testing Lab 12919 NE 126 Place Kirkland, WA 98033 425 823 -9800 425 586 -2203 FAX x B uilding Services 220 4th Avenue South Kent, WA 98032 - 5895 (253) 856 -5400 FAX: (253) 856 -6454 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 6 Z009 City of Tukwila BUILDING DIlim'r CTL crh, I s4-t r1 Lab 10111 S. Tacoma Way #D -7 Tacoma, WA 98499 253 383- 8178 3s 3-- 8 - 1 d c' Ph-r - Y2-- , ZS?)- 3 o3 -u31 GeolTest Services Inc. 741 Marine Dr. Bellingham, WA 98225 360 733 -7318 360733 -7418 FAX CORRECTION LTR# Testing Labs Materials Testing Laboratories Authorized to Perform Special Inspection per UBC Section 1701 Krazan & Assoc. " $ 25418 74th AV S If Co Kent, WA 9A °32 ° t N O p 253 854-133V `' '. ,, - • 253 8541757 FAX Materials Testing & Consulting 1687 Old Hwy 99 S MT Vernon, WA 98273 360 428 -0900 360 428 -6082 FAX Mayes Testing Engineers, Inc. 917 134th St. SW Suite A -1 Everett, WA 98204 425 742 -9360 425 745 -1737 FAX Otto Rosenau and Associates 6747 Martin Luther King Way S. Seattle, WA 98118 206 725 -4600 206 723 -2221 FAX Professional Service Industries /PSI (formerly Pacific Testing Laboratories) 3257 16th Ave W. Seattle, WA 98119 206 282 -0666 206 282 -0710 FAX . 00 S-'1 -604o* !wiz, RECEIVE' OCT23 PERMIT CENTEI bsd10 53 2:101 p. 1 of 1 I IiH' tqco'Ffre & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series ELO -231 Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description The 11.2 K- factor, Series ELO -231, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the fusible solder type. They are "standard response - spray sprin- klers" that produce a hemispherical water distribution pattern below the deflector. The 11.2 K- factor, ELO -231 Sprinklers were subjected to full scale, high -piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K- factor standard spray sprinklers for the protection of high -piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K- factor, ELO -231 Sprinklers — mak- ing their use highly advantageous in high density applications, such as the protection of high -piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO -231 sprin- klers beyond that which would other- wise be obtained when exposed to corrosive atmospheres. Although wax and lead coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all pos- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- ' stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. sible corrosive atmospheres. Conse- quently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resis- tant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemi- cals, and gas /chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An upright intermediate level version of the Series ELO -231 Sprinklers for in -rack applications can be obtained by utilizing the Series ELO -231 Up- right Sprinkler with the WSG -2 Guard & Shield, and a pendent intermediate level version of the Series ELO -231 Sprinklers can be obtained by utiliz- ing the Series ELO -231 Pendent Sprinkler with the WS -2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G -2 Guard can be added. WARNINGS The 11.2 K- factor, Series ELO -231 Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in comp document, as well as ble standards of the tection Association, i standards of any othe ing jurisdiction. Failu Impair the performa vices. The owner is respons ing their fire protectio vices in proper ope The installing contra tuner should be con questions. Installation of Series ELO -231 Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and /or Listings. wr le for maintain - syste $ d de- ting r ', .- F ILE Co Permit No. P n review approval ip si hi0-4 ED PLIANCE auth OV ED i RECEIVED LA t CITY s E A e o osom =y ce of t►j�e d- 6 2009 JUN 2 3 71 ing Tukwila PERMIT CENTER DIVIRION I CORRECTION LTR # _�= Y Page 1 of 6 MARCH, 2007 TFP340 Page 2 of 6 NOTES: 1 Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL Listed). 3. Approved by Factory Mutual Research Corporation (FM Approved). 4. Approved by the City of New York under MEA 291 -04 -E. (a). Listed /Approved for a maximum ceiling temperature of 150 °F /66 °C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K- FACTOR SERIES ELO-231 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Technical Identification Data Numbers TY5111 TY5211 TY5811 TY5111 TY5211 TY5811 - Upright 11.2K, 3/4 "NPT - Pendent 11.2K, 3/4 "NPT - Upright 11.2K, 112 "NPT is a redesignation for C5111. is a redesignation for C5211. is a redesignation for C5811. Approvals UL and C -UL Listed. FM and NYC Ap- proved.(Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 11.2 GPM /psi / (161,4 LPM /bar Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame Bronze Seal Disc Copper Cap Bronze Strut Assembly . Solder, Bronze, Stainless Steel Bronze Bronze Stainless Steel Nickel Stainless Steel Compression Screw Deflector Helper Spring ... Ejector Spring Strut Clip TFP34O Design Criteria UL and C -UL Listing Requirements The 11.2 K- factor, Model ELO -231 (TY5111, TY5211 & TY5811) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area /density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies, as well as high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not lim- ited to Class I -IV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. FM Approval Requirements The 11.2 K- factor, Model ELO -231 (TY5111, TY5211 & TY5811) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity /area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C -UL Listing criteria.) SPRINKLER FINISH TYPE TEMPERATURE FRAME COLOR NATURAL BRASS CHROME PLATED LEAD WAX COATED COATED WAX OVER LEAD UPRIGHT 165 °F /74 °C Unpainted 1, 2, 3, 4 (TY5111 212 °F /100 ° C White 1, 2, 3, 4 & 286 °F /141 °C Blue 1, 2, 3, 4 I 1(a) , 2(8), 3(a), 4(a) TY5811) 165 °F /74 °C Unpainted 1, 2, 4 PENDENT 212 °F /100 ° C White 1, 2, 3, 4 (TY5211 286 °F /141 °C Blue 1, 2, 4 I 1(a) , 2(a), 4(a) Page 2 of 6 NOTES: 1 Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL Listed). 3. Approved by Factory Mutual Research Corporation (FM Approved). 4. Approved by the City of New York under MEA 291 -04 -E. (a). Listed /Approved for a maximum ceiling temperature of 150 °F /66 °C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K- FACTOR SERIES ELO-231 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Technical Identification Data Numbers TY5111 TY5211 TY5811 TY5111 TY5211 TY5811 - Upright 11.2K, 3/4 "NPT - Pendent 11.2K, 3/4 "NPT - Upright 11.2K, 112 "NPT is a redesignation for C5111. is a redesignation for C5211. is a redesignation for C5811. Approvals UL and C -UL Listed. FM and NYC Ap- proved.(Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 11.2 GPM /psi / (161,4 LPM /bar Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame Bronze Seal Disc Copper Cap Bronze Strut Assembly . Solder, Bronze, Stainless Steel Bronze Bronze Stainless Steel Nickel Stainless Steel Compression Screw Deflector Helper Spring ... Ejector Spring Strut Clip TFP34O Design Criteria UL and C -UL Listing Requirements The 11.2 K- factor, Model ELO -231 (TY5111, TY5211 & TY5811) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area /density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies, as well as high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not lim- ited to Class I -IV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. FM Approval Requirements The 11.2 K- factor, Model ELO -231 (TY5111, TY5211 & TY5811) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity /area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C -UL Listing criteria.) TFP340 Temperature rating is Indicated on deflector. ** Pipe thread connections per ISO 7/1 can be provided on special request. 2- 13116 "_ (71,4 mm) TYP. it 7/16" (11,1 mm) NOMINAL MAKE -IN UPRIGHT TY5811 T - 1/2" (12,7 mm) NOMINAL MAKE -IN UPRIGHT TY5111 1/2" (12,7 mm) NOMINAL MAKE -IN PENDENT TY5211 CROSS SECTION Components: 1 - Frame 2 - Seal Disc 3 - Cap 4 - Strut Assembly 5 - Compression Screw 6 - Deflector * 7 - Helper Spring 8 - Ejector Spring 9 - Strut Clip FIGURE 1 11.2 K- FACTOR SERIES ELO-231 UPRIGHT - 3/4 " NPT (TY5111), UPRIGHT - 1/2" NPT (7Y5811), AND PENDENT - 3/4" NPT (TY5211) SPRINKLERS Operation A fusible alloy is sealed into a bronze actuating rod (center strut) by a stain- less steel ball. When the alloy melts at its rated temperature, the ball is forced upward into the center strut, releasing the two ejectors and operating the sprinkler. Installation The Series ELO -231 Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon plate by under- or over - tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series ELO -231 Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W -Type Page 3 of 6 "FITTING SIDE" TOWARDS SPRINKLER FITTING FIGURE 2 W -TYPE 3 SPRINKLER WRENCH WRENCH RECESS (END "A ") 3 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1, the W -Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench fiats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen Page 4 of 6 TFP340 the wrench jaws before removing the wrench. After installation, the sprinkler wrench flats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one -half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO -231 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied or over - heated sprinklers must be replaced. Care must be exercised to avoid dam- age to the sprinklers — before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close -up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and /or national code. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and /or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, Including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties gf merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. 110 UPRIGHT 3/4" NPT (TY5111) 112 PENDENT 3/4" NPT (TY5211) 210 UPRIGHT 1/2" NPT (TY5811) TFP34O Page 5 of 6 Ordering Procedure A Part Number (P /N) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K- factor, (specify temperature rating), Series ELO -231 Standard Response (specify Pendent or Upright) Sprinkler with (specify finish), P/N (specify from Ta- ble B). Sprinkler Wrench: Specify: W -Type 3 Sprinkler Wrench, P/N 56- 895 - 1-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries ELO -231 Sprinklers, P/N (spec- ify). Red for 165 °F P/N 56-065 -1 -155 Blue for 212 °F and 286 °F P/N 56 -065-1 -288 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286 °F sprinklers is the same as for 212 °F sprinklers, and, therefore, the 286 °F sprinkler is limited to the same maximum ceiling tempera- ture as the 212 °F sprinkler (i.e., 150 °F). TYPE P/N 50 - XXX - X - XXX 1 9 6 7 8 SPRINKLER NATURAL BRASS CHROME PLATED WAX COATED LEAD COATED WAX OVER LEAD l 165 212 286 TEMPERATURE RATING 165 °F /74 °C 212 °F /100 °C 286 °F /141 °C TABLE B PRODUCT SYMBOL NUMBER SELECTION 11.2 K- FACTOR SERIES ELO-231 STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Page 6 of 6 TFP34O TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 La Panzanella Job Name: La Fanzanella Location: 18475 Olympic Avenue South Tukwila, WA 98188 Permit No. Drawing Date: 03 -12 -09 Remotp r p.Number: 1 Contractor: Simplex Grinnell Teleppone : D' ` ?Imm bi§ subiert SYSTEM DESIGN Code:NFPA 13 Area of Sprinkler Oper. Density (gpm /sq ft) Area per Sprinkler Hose Allowance Inside Hose Allowance Outside WATER SUPPLY Drawing Date:03 -12 -09 5/12/09 15:54 HYDRAULIC DESIGN INFORMATION SHEET 9520 10th Avenue South, Suite 100 �� 0 P'r+r, rimi Seattle, WA 98108 Designer: 206 - 291 -1500 Calculated By:SprinkCAD www.sprinkcad.com 451 N. Cannon Ave. Lansdale, PA 19446 Construction: Flammable Reviewing Authorities:City of Tukwila Hazard:EXTRA HAZAD System Type:y City of T u k wila LI NGDIV I,S►pn 2000 sq ftl Sprinkler or Nozzle 0.600 l Make: TYCO 98.7 sq ftl Model: ELO -231 0 gpm I K- Factor:11.20 500 gpm I Temperature Rating: 286 CALCULATION SUMMARY 23 Flowing Outlets gpm Required: 2094.9 psi Required: 85.5 @ City Supply Water Flow Test I Pump Data Date of Test 03 -11 -09 1 Rated Capacity 0 gpm Static Pressure 150.0 psi I Rated Pressure 0.0 psi Residual Pres 20.0 psi 1 Elevation 0 At a Flow of 4563 gpm 1 Make: Elevation 0" 1 Model: Location: Location J SOuth Olympic Avenue Source of Information: Tukwila Public Works SYSTEM VOLUME 1162 Gallons Notes: Storage area only Occupancy:Extra Hazard CORRECTION T R # . FILE COPY CO���C A PPgo FD JUL 0 6 2009 RECVED C EI ITY OF TU�KwWWLA duN 73 2009 PERMIT CENTER La Fanzanella Drawing Date:03 -12 -09 HYDRAULIC CALCULATION DETAILS HYDRAULIC QTY DESCRIPTION LENGTH C ID Hydr Ref W Required at Hyd Area 1 1595 Elevation Change 22'2" 1 8" Grvd 90 Ell 18' 120 8.071 1595 1 Pipe 8" 10x25 18' 120 8.249 1595 1 8" Flngd Alarm Valve "F" CHART LOSS 1595 1 8" Flngd Gate Valve "721U" PIV 4' 120 8.071 1595 1 8" Companion Flange 0' 120 8.071 1595 1 Pipe 8" DIx18 Cl 350 1' 140 8.488 1595 1 8" Grvd Coupling 0' 120 8.071 1595 1 Pipe 8" 10x25 1' 120 8.249 1595 1 8" Companion Flange 0' 120 8.071 1595 Hydr Ref R1 1 Pipe 8" DIx18 Cl 350 1 10" Flngd 90 Ell 1 Pipe 10" DIx18 Cl 350 1 12" x 10" Flngd Reducer 1 12" Flngd Tee Total Loss for Riser Required at Base of Riser 6' 140 8.488 22' 120 10.140 30' 140 10.518 0' 120 11.938 60' 120 11.938 Fixed Flow Outside Hose Stream 5/12/09 15:54 FLOW LOSS gpm psi TOTALS 9.6 0.4 0.3 0.9 0.1 0.0 0.0 0.0 0.0 0.0 1595 1595 0.1 1595 0.2 1595 0.1 1595 0.0 1595 0.2 500 gpm Total Loss for Underground 0.5 psi Hydr Ref R2 Required at City Supply 2095 85.5 psi Water Source150.0 psi static, 20.0 psi residual @ 4563 gpm 2095 gpm 119.2 psi SAFETY PRESSURE 33.7 psi Available Pressure of 119.2 psi Exceeds Required Pressure of 85.5 psi This is a safety margin of 33.7 psi or 28 % of Supply Maximum Water Velocity is 35.8 fps 73.7 psi 11.3 psi 85.0 psi La Panzanella NOTES: ABBREV. NAME Drawing Date:03 -12 -09 5/12/09 15:54 FITTING NAME TABLE C Coupling E 90' Standard Elbow F 45' Elbow S Straight Flow Thru Tee T 90' Flow Thru Tee ✓ Valve LEGEND HYD REF Hydraulic reference. Refer to accompanying flow diagram. K FACTOR Flow factor for open head or path where Flow (gpm) = K x - \/P Qa Flow added or subtracted Qt Total flow DIA Actual internal diameter of pipe C Hazen Williams pipe roughness factor Pf /ft Friction loss per foot of pipe PIPE Length of pipe FTNG'S Number of fittings. See table above. TOTAL Total length (PIPE + FTNG'S) Pt Total pressure (psi) at fitting Pe Pressure due to change in elevation where Pe = 0.433 x change in elevation Pf Friction loss (psi) to fitting where Pf = 1 x 4.52 x (Q /C) ^1.B5 / ID ^4.87 Pv Velocity pressure (psi) where Pv = 0.001123 x Q ^2 /ID ^4 Pn Normal pressure (psi), where Pn = Pt - Pv - Pressures are balanced to 0.01 psi. Pressures are listed to 0.1 psi. Addition may vary by 0.1 psi due to accumulation of round off. - Calculations conform to NFPA 13. - Velocity Pressures are not considered in these Calculations Page 3 La Fanzanella Drawing Date:03 -12 -09 5/12/09 15:54 NODE NUMBER ELEVATION 1 23.42 2 23.42 3 23.42 4 23.42 5 23.42 6 23.42 7 23.42 8 23.42 9 23.42 10 23.42 11 23.42 12 23.42 13 23.42 14 23.42 15 23.42 16 23.42 17 23.42 18 23.42 19 23.42 20 23.42 21 23.42 22 23.42 23 23.42 50 23.42 51 23.42 52 23.42 53 23.42 54 23.42 60 23.42 61 23.42 62 23.42 63 23.42 64 23.42 65 23.42 66 23.42 67 23.42 68 23.42 69 23.42 110 23.42 Al 22.17 A2 22.17 A3 22.17 A4 22.17 AS 22.17 A6 22.17 A7 22.17 A8 22.17 A9 22.17 B5 22.17 B6 22.17 Cl 22.17 SPRINKLER K- FACTOR (FT) (GPM /(PSI^%%)) 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 11.20 Page 4 PRESSURE ACTUAL MINIMUM ACTUAL FLOW FLOW DENSITY (GPM) (GPM) (GPM /SQ.FT) (PSI) 28.0 28.9 35.1 36.3 40.6 32.5 33.6 37.6 37.4 38.7 43.3 36.4 37.6 42.1 38.6 39.9 44.7 37.5 38.8 43.4 42.1 43.5 48.7 51.7 39.1 57.8 59.5 66.6 72.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3 72.3 63.4 65.7 65.8 67.6 67.8 69.4 69.5 70.2 72.9 72.9 72.9 72.9 59.2 59.2 0.60 60.2 59.2 0.61 66.4 59.2 0.67 67.5 59.2 0.68 71.4 59.2 0.72 63.8 59.2 0.65 64.9 59.2 0.66 68.7 59.2 0.70 68.5 59.2 0.69 69.7 59.2 0.71 73.7 59.2 0.75 67.5 59.2 0.68 68.7 59.2 0.70 72.7 59.2 0.74 69.6 59.2 0.71 70.7 59.2 0.72 74.8 59.2 0.76 68.6 59.2 0.69 69.7 59.2 0.71 73.8 59.2 0.75 72.7 59.2 0.74 73.9 59.2 0.75 78.2 59.2 0.79 La Panzanella W Drawing Date:03 -12 -09 NODE ELEVATION SPRINKLER PRESSURE NUMBER K- FACTOR (FT) (GPM /(PSI ^)) (PSI) 22.17 73.7 Max velocity of 35.77 occurs in the pipe from 23 TO 54 5/12/09 15:54 Page 5 ACTUAL FLOW (GPM) MINIMUM ACTUAL FLOW DENSITY (GPM) (GPM /SQ.FT) La Panzanella HYD. REF POINT 1 5 Al DIA. 'I Qt Pf /ft Qa 59.22 1.610 C =120 59.22 0.120 Drawing Date:03 -12 -09 Tyco Fire Products FITTING TYPES PIPE Pt FTNG'S Pe TOTAL Pf PATH 1 FROM HYDRAULIC REFERENCE 1 TO W (PRIMARY PATH) UNITS - DIAMETER (INCH) LENGTH (FOOT) 5/12/09 15:54 Page 6 Pt Pv * * * * * ** NOTES * * * * * ** Pn 8.00 28.0 28.0 K = 11.20 0.00 0.0 0.0 8.00 1.0 28.0 Vel = 9.42 60.23 1.610 lE 11.00 28.9 28.9 K = 11.20 2 C =120 1T 12.00 0.0 0.0 119.45 0.441 23.00 10.1 28.9 Vel = 19.01 133.91 2.067 3.00 39.1 39.1 51 C =120 0.00 0.0 0.0 See PATH 3 253.36 0.525 3.00 1.6 39.1 Vel = 24.46 71.39 2.067 1T 3.35 40.6 40.6 K = 11.20 C =120 10.00 0.0 0.0 324.75 0.830 13.35 11.1 40.6 Vel = 31.35 197.37 2.469 1T 1.25 51.7 51.7 50 C =120 12.00 0.5 0.0 See PATH 2 522.13 0.841 13.25 11.1 51.7 Vel = 35.33 3.260 10.33 63.4 63.4 C =120 0.00 0.0 0.0 522.13 0.217 10.33 2.2 63.4 Vel = 20.27 4.260 2.00 65.7 65.7 A2 C =120 0.00 0.0 0.0 522.13 0.059 2.00 0.1 65.7 Vel = 11.87 420.75 4.260 10.33 65.8 65.8 A3 C =120 0.00 0.0 0.0 See PATH 4 942.88 0.176 10.33 1.8 65.8 Vel = 21.43 5.000 2.00 67.6 67.6 A4 C =120 0.00 0.0 0.0 942.88 0.081 2.00 0.2 67.6 Vel = 15.56 427.30 5.000 10.33 67.8 67.8 AS C =120 0.00 0.0 0.0 See PATH 6 1370.18 0.161 10.33 1.7 67.8 Vel = 22.61 6.357 2.00 69.4 69.4 A6 C =120 0.00 0.0 0.0 1370.18 0.050 2.00 0.1 69.4 Vel = 13.99 FLOW (GPM) PRESSURE (PSI) La Panzanella Drawing Date:03 -12 -09 Tyco Fire Products HYD. REF POINT Qa DIA. ,, Qt Pf /ft 224.76 6.357 A7 C =120 1594.94 0.066 FITTING TYPES PIPE Pt FTNG'S Pe TOTAL Pf PATH 1 FROM HYDRAULIC REFERENCE 1 TO W (PRIMARY PATH) 10.33 0.00 10.33 69.5 0.0 0.7 69.5 0.0 69.5 5/12/09 15:54 Pt Pv * * * * * ** NOTES * * * * * ** Pn See PATH 8 Vel = 16.28 8.249 1T 103.13 70.2 70.2 A8 C =120 38.92 0.0 0.0 1594.94 0.019 142.05 2.7 70.2 Vel = 9.67 8.249 1E 26.44 72.9 72.9 A9 C =120 20.02 0.0 0.0 1594.94 0.019 46.46 0.9 72.9 Vel = 9.67 W 1594.94 PATH 2 FROM HYDRAULIC REFERENCE 6 TO 50 6 7 8 50 197.37 PATH 3 FROM HYDRAULIC REFERENCE 3 TO 51 3 63.81 1.610 C =120 63.81 0.138 66.40 1.610 C =120 66.40 0.149 UNITS - DIAMETER (INCH) LENGTH (FOOT) 73.7 K = 185.75 8.00 32.5 32.5 K = 11.20 0.00 0.0 0.0 8.00 1.1 32.5 Vel = 10.15 64.88 1.610 8.00 33.6 33.6 K = 11.20 C =120 0.00 0.0 0.0 128.69 0.506 8.00 4.0 33.6 Vel = 20.48 68.68 1.610 1T 4.65 37.6 37.6 K = 11.20 C =120 8.00 0.0 0.0 197.37 1.116 12.65 14.1 37.6 Vel = 31.41 51.7 K = 27.44 8.00 35.1 35.1 K = 11.20 0.00 0.0 0.0 8.00 1.2 35.1 Vel = 10.57 Page 7 FLOW (GPM) PRESSURE (PSI) La Fanzanella HYD. REF POINT PATH 3 FROM HYDRAULIC REFERENCE 3 TO 51 CONTINUED 4 51 133.91 Qa DIA. "C" Qt Pf /ft 67.51 1.610 C =120 133.91 0.545 Drawing Date:03 -12 -09 Tyco Fire Products FITTING TYPES PIPE FTNG'S TOTAL PATH 4 FROM HYDRAULIC REFERENCE 12 TO A3 Pt Pe Pf 5/12/09 15:54 Pt Pv * * * * * ** NOTES * * * * * ** Pn 5.00 36.3 36.3 K = 11.20 0.00 0.0 0.0 5.00 2.7 36.3 Vel = 21.31 39.1 K = 21.43 67.54 1.610 8.00 36.4 36.4 K = 11.20 12 C =120 0.00 0.0 0.0 67.54 0.153 8.00 1.2 36.4 Vel = 10.75 68.67 1.610 8.00 37.6 37.6 K = 11.20 13 C =120 0.00 0.0 0.0 136.21 0.562 8.00 4.5 37.6 Vel = 21.68 72.66 1.610 1T 4.65 42.1 42.1 K = 11.20 14 C =120 8.00 0.0 0.0 208.86 1.239 12.65 15.7 42.1 Vel = 33.24 211.89 2.469 1T 1.25 57.8 57.8 52 C =120 12.00 0.5 0.0 See PATH 5 420.75 0.564 13.25 7.5 57.8 Vel = 28.47 A3 420.75 PATH 5 FROM HYDRAULIC REFERENCE 9 TO 52 9 65.8 K = 51.88 68.52 1.610 8.00 37.4 37.4 K = 11.20 C =120 0.00 0.0 0.0 68.52 0.158 8.00 1.3 37.4 Vel = 10.90 69.67 1.610 8.00 38.7 38.7 K = 11.20 10 C =120 0.00 0.0 0.0 138.19 0.577 8.00 4.6 38.7 Vel = 21.99 UNITS - DIAMETER (INCH) LENGTH (FOOT) Page 8 FLOW (GPM) PRESSURE (PSI) La Panzanella HYD. REF POINT 11 Qa 52 211.89 DIA. C Qt Pf /ft 73.70 1.610 1T C =120 211.89 1.273 Drawing Date:03 - 12 - 09 Tyco Fire Products FITTING TYPES PIPE FTNG'S TOTAL PATH 6 FROM HYDRAULIC REFERENCE 18 TO A5 Pt Pe Pf PATH 5 FROM HYDRAULIC REFERENCE 9 TO 52 CONTINUED 5/12/09 15:54 Pt Pv * * * * * ** NOTES * * * * * ** Pn 3.35 43.3 43.3 K = 11.20 8.00 0.0 0.0 11.35 14.5 43.3 Vel = 33.72 57.8 K = 27.88 68.59 1.610 8.00 37.5 37.5 K = 11.20 18 C =120 0.00 0.0 0.0 68.59 0.158 8.00 1.3 37.5 Vel = 10.92 69.74 1.610 8.00 38.8 38.8 K = 11.20 19 C =120 0.00 0.0 0.0 138.33 0.578 8.00 4.6 38.8 Vel = 22.01 73.78 1.610 1T 4.65 43.4 43.4 K = 11.20 20 C =120 8.00 0.0 0.0 212.11 1.275 12.65 16.1 43.4 Vel = 33.76 215.18 2.469 1T 1.25 59.5 59.5 53 C =120 12.00 0.5 0.0 See PATH 7 427.30 0.581 13.25 7.7 59.5 Vel = 28.91 A5 427.30 PATH 7 FROM HYDRAULIC REFERENCE 15 TO 53 UNITS - DIAMETER (INCH) LENGTH (FOOT) 67.8 K = 51.91 69.59 1.610 8.00 38.6 38.6 K = 11.20 15 C =120 0.00 0.0 0.0 69.59 0.162 8.00 1.3 38.6 Vel = 11.07 70.75 1.610 8.00 39.9 39.9 K = 11.20 16 C =120 0.00 0.0 0.0 140.34 0.594 8.00 4.8 39.9 Vel = 22.33 Page 9 FLOW (GPM) PRESSURE (PSI) La Panzanella HYD. REF POINT 53 215.18 Qa DIA. " Qt Pf /ft FITTING TYPES 72.70 1.610 21 C =120 72.70 0.176 Drawing Date:03 -12 -09 Tyco Fire Products PIPE FTNG'S TOTAL Pt Pe Pf PATH 7 FROM HYDRAULIC REFERENCE 15 TO 53 CONTINUED PATH 8 FROM HYDRAULIC REFERENCE 21 TO A7 59.5 5/12/09 15:54 Pt Pv * * * * * ** NOTES * * * * * ** Pn 74.84 1.610 1T 3.35 44.7 44.7 K = 11.20 17 C =120 8.00 0.0 0.0 215.18 1.310 11.35 14.9 44.7 Vel = 34.24 K = 27.89 8.00 42.1 42.1 K = 11.20 0.00 0.0 0.0 8.00 1.4 42.1 Vel = 11.57 73.90 1.610 8.00 43.5 43.5 K = 11.20 22 C =120 0.00 0.0 0.0 146.60 0.644 8.00 5.2 43.5 Vel = 23.33 78.15 1.610 1T 4.65 48.7 48.7 K = 11.20 23 C =120 8.00 0.0 0.0 224.76 1.419 12.65 17.9 48.7 Vel = 35.77 2.469 1T 1.25 66.6 66.6 54 C =120 12.00 0.5 0.0 224.76 0.177 13.25 2.3 66.6 Vel = 15.21 A7 224.76 69.5 K = 26.95 UNITS - DIAMETER (INCH) LENGTH (FOOT) Page 10 FLOW (GPM) PRESSURE (PSI) S I 280 240 200 P 160 120 80 40 Job La Panzanella 18475 Olympic Avenue South Tukwila, WA 98188 Remote Area: 1 10.1 psi 500 gpm hose Supply 600 900 1200 Water Static Pres: 150.0 psi Resid. Pres: 20.0 psi Flow: 4563 gpm Date: 03 -11 -09 Loc: Location J SOuth Olympic 1500 1800 Required Pressure: 85.5 psi Sys Flow: 1595 gpm Sys +Hose: 2095 gpm Safety Pres: 33.7 psi Hd Ely Pres: 10.1 psi 2100 Flow (gpm) Hose Allowance In: 0 gpm Out: 500 gpm 2400 2700 3000 nnnnn mnnnnnnnnnnnuunmm11mumnmuunnnunmm11nmm11nnnnnnnunnnnnnnmuumumnnnnnnnnnumnnumuuum Jennifer Marshall Permit Technician City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite 100 Tukwila, WA 98188 -2599 I env O TtiKwu • !JUN 2 3 2009 PERMIT CENTER Jennifer, In response to your rejection of our 90 day extension -because we did not respond to the October 17, 2008. I am• very sorry I did not realize that I needed to respond — I just worked with Al to answer the questions and send us on a path to get the permit accepted by the city of Tukwila. Please find attached the final decision on the classification of plastic and our documentation to support our racking configuration that was found to be acceptable to Mr. Metzler. Simplex - Grinnell has put in for a permit to replace all the sprinkler heads in our building — as I understand' it we are about two weeks from that being signed off — once they get the approval we are going to make our facility available so the work can start immediately. Once they have replaced the sprinkler heads we will be ready•to have our inspection. I ask respectfully to have our Permit D08 -459 extended another 90 days. Thank you Ronald Hacker La Panzanella 425- 318 -2410 18475 Olympic .goe. cs. - JuJ.w,fa, 7.0 - 9Gone (206 903 -0500 — Jax (206) 903 -0698 — www.lapanzanella. corn n u June 15, 2009 Ron Hacker La Panzanella 18475 Olympic Av S Tukwila, WA 98188 RE: Request for Application Extension #2 Development Permit Application No. D08 -459 La Panzanella — 18475 Olympic Av S Dear Mr. Hacker: This letter is in response to your written request for an additional extension to Application Number D08- 459. The Building Official has reviewed your letter and considered your request to extend the above referenced permit and will not be extending the expiration date. A previous 90 day extension was granted in order to provide time for a response to the correction letter mailed out on October 17, 2008. No response has been received and therefore no extension will be granted. Any work on this project will require a new application submittal including a clean set of plans, specifications, and calculations as required. Please note that new permit fees will be assessed accordingly. Sincerely, File: ifer M. rshall it Technician Permit No. D08 -459 • City of Tukwlla Department of Communi4/ Development W:'Permit Center1Extension Letters \Denials\Applications\D08 -459 Application Ext Denial.doc jent • Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 ® Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 IIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIII Bill Rambo Permit Technician City of Tukwila Department of Community Development 6300 Southcenter Boulevard Suite 100 Tukwila, WA 98188 -2599 RE: Permit No. D08 -404 and D08 -459 18475 Olympic AV S TUKW Bill, I am working with the fire department to complete a request they have. I have settled on the contractor to fix our fire system to meet the requirement as laid out by the City of Tukwila fire department. They are putting in for a permit and once that clears we are going to have them complete the work as quickly as possible. Once that is completed we can have the fire department sign off and we can close out all of our permits. We are asking for a 90 day extension so we can finish the final items. Thank you for you consideration in this matter Ron Hacker La Panzanella LLC 425- 318 -2410 De 0L1 j i3O 1 061 b �sq )- Lj - OR •E v 'S l . rQ y-e4 J . - b Dc- 212-Do , res ;L -4A e ers v' re41 ued- IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII of Av RECENED CITY OF TU!(WIL,A IJUN 1 0 2009 PERMI f "r 18475 Olympic . cs. - 7ulzcurfa ✓1 98188 - _`/ one (206 903 -0500 - :7ax (206 903 -0698 - www. /apanzanella. corn • 06 -03 -2009 DAVID KEHLE 1916 BONAR DR SW SEATTLE WA 98116 RE: Permit Application No. D08 -459 18475 OLYMPIC AV S TUKW Dear Permit Applicant: • City of Tu/ is • Department of Commonliy Development Jim Haggerton, Mayor Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 10/08/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 07/05/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/05/2009. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. D08 -459 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 March 12, 2009 Ron Hacker La Panzanella 18475 Olympic Av S Tukwila WA 98188 RE: Request for Application Extension #1 Development Application No. D08 -459 La Panzanella —18475 Olympic Av S Dear Mr. Hacker, This letter is in response to your written request for an extension to Permit Application Number D08 -459. The Building Official has reviewed your letter and considered your request. It has been determined that the City of Tukwila will be extending the permit application expiration date an additional 90 days, through July 4, 2009. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, i At(TA er Marshall Technician File: Permit No. D08 -459 S • Department of Community Development P:\Permit Center\Extension Letters \Applications\2008\D08 -459 Application Extension.doc jem Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 a Fax: 206 - 431 -3665 uNINNNNNINNNNNNINNNNNNNNNIIINNNNNNNNNNNNNNNNNNNINNNNNNNNIIINNNNNNNNNNNNNNNNNINNNNlNNN1 tra Jennifer Marshall City of Tukwila Department of Community Development 3201 l Ave S #209 l (i o�, Seattle, WA 98134 04112 -k 040(0 0-1 RE: Permit No. D08 -404 and 108 -459 18475 Olympic AV S TUKW IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1111I,NNII iteee MAR 1 11009 PERma cErvrEI1 Jennifer, I am working with the fire department to complete a request they have. I need an outside service come in and do an analysis on our fire protection system, then I can get with the city of Tukwila fire department to evaluate the method of storage for some of the materials we plan on having in our building. We are asking for a 90 day extension so we can finish the final few items. Thank yo for you consi • eration in this matter V Ron Hacker La Panzanella LLC 425- 318 -2410 an, 40.&%totied 2 .-zziezmi_ceai dal° o yi0/oy M475 Olympic gue. cS. - ✓uumrla, Zg98188 - JKsone (206) 903 -0500 - ax (206) 903 -0698 - mazy. Japanzanella. corn 03 -02 -2008 DAVID KEHLE 1916 BONAR DR SW SEATTLE WA 98116 RE: Permit Application No. D08 -459 18475 OLYMPIC AV S TUKW Dear Permit Applicant: • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current permit application files, it appears that your permit application applied for on 10/08/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 04/06/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/06/2009. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall Technician Permit File No. D08 -459 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 November 17, 2008 David Kehle 1916 Bonair Drive SW Seattle, WA 98116 RE: CORRECTION LETTER #2 Development Application Number D08 -459 La Panzanella —18475 Olympic Avenue S Dear Mr. Kehle: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Fire Department. At this time the Building Department has no comments. Fire Department: Al Metzler at 206 -575 -4404 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messen,4er service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, fer Marshall t Technician encl File No. D08 -459 P:\Pennit Center \ Correction Letters \2008\D08 -459 Correction Ltr #2.DOC jem • • Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 e Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 Project Name: La Panzanella 18475 Olympic Av S Permit File No.: D08 -459 Date: November 12, 2008 • • FIRE DEPARTMENT REVIEW COMMENTS Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575 -4407 1. Commodities memo indicates a significant quantity of plastics which will be stored on 16 ft. high racks with an unknown total storage height. The specific types of plastics, i.e. Group A. Group B are not known as well as the breakdown on quantities of each. 2. Provide an engineering analysis prepared by a licensed Fire Protection Engineer indicating this storage arrangement will have adequate fire protection per NFPA 13, 2007 edition, including appropriate sprinkler densities. • Lt kehJe October 23, 2008 City of Tukwila 6200 Southcenter Blvd. Tukwila, Washington 98188 Attn: Ms. Brenda Holt Re: La Panzanella, LLC — D08 -459 18475 Olympic Avenue So. Dear Brenda, I am in receipt of your Correction Letter #1 dated October 17, 2008 and the following addresses the comment letters from Allen and Al. A. Building Division: Allen Johannessen 1. Attached is the 8 -1/2 x 11 calculation (Sheet 3) with the note "Special Inspection is required" (at anchor spec.). Please attach to the sets. In addition I have added a note to Sheet T -1 referring to the calculations and specifying special inspections required. 2. I have enclosed a Special Inspection Form. B Fire Department: Al Metzler 1. Information on Commodities Stored: I have attached a memo from the owner listing what they are storing. The plan tells what is in the rack (finished goods, packaging, etc.) which tie to his memo. I trust this will suffice to issue the permit for the above project. If you have any further questions or comments, please call. David Kehle DK/mt Enclosure: Two Sets of Plans cc: Mr. Ron Hacker 0804/citylet10-23-08 1916 Bonair Drive S.W. Seattle, WA 98116 CORRECTION LTR# 1O8 RECE WED OCT 23 2008 PERMIT CENTEI- L i q (206) 433 -8997 fax (206) 246 -8369 email: dkehle @dkehlearch.com October 17, 2008 David Kehle 1916 Bonair Drive SW Seattle, WA 98116 RE: CORRECTION LETTER #1 Development Application Number D08 -459 La Panzanella —18475 Olympic Avenue S Dear Mr. Kehle: This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Fire Department: Al Metzler at 206 - 575 -4404 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, twat -10 Brenda Holt Permit Coordinator encl File No. D08 -459 Department of Community Development P:\Permit Center\Correction Letters\2008\D08 -459 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: October 13, 2008 Project Name: La Panzanella Permit #: D08- 459 Plan Review: Allen Johannessen, Plans Examiner • Tukwila Building n Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Engineer calculations specify HILTI KB -TZ anchors for securing storage rack base plates. Calculations reference bolt installation per ESR -1917 where the report specifies "Special Inspection is required ". Please provide notes on the plans and in the engineer's calculations that specify special inspection requirements for the storage rack installation. (IBC 1704 -13 & 1707.6) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. Project Name: La Panzanella 18475 Olympic Av S Permit File No.: D08 -459 Date: October 15, 2008 • • FIRE DEPARTMENT REVIEW COMMENTS Reviewer: Al Metzler Fire Protection Project Coordinator (206)575 -4407 1. Provide detailed information on the commodities to be stored on the racks including the type of packaging and bags (ie. paper, corrugated cardboard, plastic, etc.) and the quantities. DEPARTMENTS: Building Division Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 flO PERMIT COORD COPY I PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -459 DATE: 06 -23 -09 PROJECT NAME: LA PANZANELLA SITE ADDRESS: 18475 OLYMPIC AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 3/ Revision # After Permit Issued U Approved Li Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Structural DETERMINATIO iN OF COMPLETENESS: (Tues., Thurs.) Incomplete Planning Division Permit Coordinator Not Applicable n DUE DATE: 06-25-09 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incdmplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TOES /THURS RO TING: Please Route Structural Review Required I I No further Review Required n REVIEWER'S INITIALS: DATE: DUE DATE: 07-23-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -459 PROJECT NAME: LA PANZANELLA SITE ADDRESS: 18475 OLYMPIC AV S Original Plan Submittal Response to Incomplete Letter # . X Response to Correction Letter # 1 DATE: 10 -23 -08 Revision # After Permit Issued DEPARTMENTS: Buil i n g Divisio 1 Public Works ❑ Complete TUES/THURS ROItfTING: Please Route �ERM9T COOK S COPY • PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2 -28 -02 ivr Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 0-28-08 Incomplete Structural Review Required [ Bldg ❑ Fire Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 11 -25 -08 Approved ❑ Approved with Conditions ❑ Not Ap proved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Ping ❑ PW ❑ Staff Initials: J f ACTIVITY NUMBER: D08 -459 DATE: 10 -08 -08 PROJECT NAME: LA PANZAN ELLA SITE ADDRESS: 18475 OLYMPIC AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1 / Buil�� g�ori y Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 171 Incomplete n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ro Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ip PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP �?! t CiAttl I V i-t25 Fire Prevention Structural n Planning Division ❑ Permit Coordinator n DUE DATE: 10-09-08 No further Review Required DATE: DUE DATE: 11-06-08 Approved I Approved with Conditions Not Approved (attach comments) 1i Notation: REVIEWER'S INITIALS: DATE: Not Applicable El Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire e Ping ❑ PW ❑ Staff Initials: a),I City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us eREVISION SUBM Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: aQ 11- I 01 ❑ Response to Incomplete Letter # RECEIVED Response to Correction Letter # I CITY OF TUpWLA ❑ Revision # after Permit is Issued JUN 2 3 nog ❑ Revision requested by a City Building Inspector or Plans Examiner PERMIT CENTER Project Name: Project Address: Contact Person: Summary of Revision: Plan Check/Permit Number: PWhtdVhalq 1`bH1-C D �i A � Pin 1�tU,�.r„f OQy W, (,i 1nrn 41,7 Phone Number: I °V, O Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received a t the City of Tukwila Permit Center by: ) ' ' Entered in Permits Plus on \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: t01/11 tog 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: LA PANZANELLA Project Address: 18475 Olympic Avenue S Contact Person: David Kehle Phone Number: lag- Summary � of Revision: e els atiumear 41tree. Sheet Number(s): Vi c 4 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D08 -459 "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Entered in Permits Plus on W CITY OF TUKWILA OCT 2 3 2008 PERMIT-CENTER 1908 COUNTY OF KING ( 1 - ?k) , N04-15 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (2n6) 431 -0670 Rey (nob) 43 - 366 5 E -mail: tukplanPci.tukwila.wa.us AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. CAI 2-- , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number _, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. . • . roposed electrical work is not for the construction of a new building for rent, sale or lease I understand that I may be waiving certai rights that I might to engage an unregistered contractor to p rform constructio er stat therwise ha e u ork. er /Owner's Agent* Signed and sworn to before me this day of , 20 O/ . e-‘60.- a (-JAA_ Residing at Permit Center /Building Division 206 431 -3670 Public Works Department 206 433 - 0179 Dl.. ". g Division rb LlvlJlVr1 206 431 -3670 PERMIT NO: cbO - /16? TA Y PUBLIC in and for the State of Washington , County Name as commissioned: My commission expires: l) 5 - a9 -/ O aw in any decision 'Lti 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or politic corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; ii. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12. Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who hobs a valid electrical contractor's license under chaptei•'19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter:19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. I. BUILDING CODE: 2. ZONING: 3. SITE AREA: 4. BUILDING AREA: BUILDING AND SITE STATISTICS 5. CONSTRUCTION TYPE: 6. OCCUPANY GROUP: 1. AREA OF REMODEL: 8. PARKING: 9. PARKING SHOWN ON SITE: TAX ID. 188890 -0111 PROPERT' WNER: SURVEYOR: 2006 INTERNATIONAL BLDG. CODE (IBC) CL1 51,331 SF ( 1.18 AC. ) APPROX. 21,488 SF FIRST FLOOR I, 652 SF SECOND FLOOR V -B SPRINKLERED F -1 - FACTORY (FORMER MEAT PACKING) B - OFFICE (ACCESSORY USE) 8,000 S.F. ± FACTORY 6 1/1500 FOR 21,184 SF : 18 CARS' OFFICE 9 1/1000 FOR 5,930 ' SF : 6 CARS' SCOPE OF WORK: INSTALL UPRIGHT STEEL RACKING FOR PRODUCT STORAGE WITH SEISMIC TIE DOWNS, SEE STRUCTURAL. TOTAL READ. 24 CARS 31 STALLS (1 WC) PAUL PIGOTT C/O LA PANZANELLA 612 SO. ALASKA ST. SEATTLE, WA 98108 GEODATUM, INC. 1505 NW MALL STREET ISSAQUAH, WA 98021 (425) 831 -8083 LEGAL DE5c1RIPT THAT PORTION OF LOT 11 SOUTHCENTER SOUTH INDUSTRIAL PARK ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 91 OF PLATS, PAGES 22, 23, 24 AND 25, INCLUSIVE, RECORDS OF KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF SAID LOT 11± THENCE SOUTH 11 °23'50” WEST ALONG TI-4E EAST LINE OF SAID LOT II, A DISTANCE OF 19.42 FEET TO THE TRUE POINT OF BEGINNING± THENCE CONTINUING SOUTH 11 °23'50" WEST A DISTANCE OF 106.11 FEET± THENCE ALONG A CURVE TO TI-1E RIGHT HAVING A RADIUS OF 50.00 FEET, AN ARC DISTANCE OF 69.62 FEET THROUGH A CENTRAL ANGLE OF 19 °41'00 "± THENCE NORTH SS °49'10" WEST A DISTANCE OF 215.51 FEET± THENCE NORTH 15 °31'46" WEST A DISTANCE OF 66.01 FEET± THENCE ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 45928 FEET, AN ARC DISTANCE O 114.60 FEET THROUGH A CENTRAL ANGLE OF 14°11 THENCE NORTH 01 °19'58" WEST A DISTANCE OF 28.00 FEET± THENCE SOUTH 18°36'10" EAST A DISTANCE OF 328.25 FEET TO THE TRUE POINT OF BEGINNING. SITUATE IN COUNTY OF KING, STATE OF WASHINGTON co \� 0 M 0. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila PUIIl..D1Na S78 °36' 10 "E 328.26' PROJECT SITE 1 1"=20.00' So. 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal "l may include additional plan review fees. S0. 180th SO. 180th s• VICINITY MAP NOT TO SCALE Site Plan CORR LTR# c boLIs9 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 6 2009 PL City of T i!a BUILDING IVISION o ° d N LE COPY Plan review approval is subject to errors and tuntsslons. Approval n docu ents does not authorize the via tion of ar adopt +1 cO ► e or o inane. Receipt of ap Ted Fl C f, , and_ i~ t ion s acknowledged' Date: L1 City Of Tukwila BUILDING DIVISION RECEIVED OCT 23 2008 PERMIT CENTEF, Cr) rn CO 00 t� 0 am - N (0 (0 O 0 N N C° U) i- LA > Z, O (f) o!� Q Z W co l— 00 Z ~ (O Q O < 0) w Q- LL. .- Ma) ■ • 0 0 II O <4' LcD 00 sED =1 Z: \CAD \2008 \0804 LA PANZENELLA \RACK PLAN \SD- 1.dwg, 10/8/2008 9:02 :12 AM, Designiet 500 MAIN.pc3 SYM DATE DESCRIPTION PROJECT 09-25-0E3 SUBMIT FOR OWNER REVIEUJ DRAWN BY TERED 10-01-0E3 REV LAYOUT PER OWNER DK ARC-leT . 10-08-05 5USMIT FOR RACK PERI-11T DATE 09-25-0E3 DAVID E.. KE LE CHECKED BY STATEOF WA6141iGTON DATE OLYMPIC i = - i 70' -0" 0 .. _ NON -BRG TO BE REMOVED WALLS — ■ — — ■ r GREASE INTECEPTOR SE , CIVIL, s • , ' « i °I TS r ■ i L • t . ■ ■ - - DOORS - v 0 T CUT IN NEW OVERHEAD 70' -0" •• 0 �� r - `•• P. 9 U 0 • T Access to Public ROW II I ' ' ❑ U I7 „0-7X _ 2 ?' -O" .. r J 1 v 0. o 0 " S LO UNDER ......J6'- Proposed silo a) w 0 a 00 aca EW SEPERATE PERM Ngg °4 ,10 „ 215.5,1' yam. sO, F] Permit No, :_ ._ ._ _ ._ 205' ._ ._ ,_ ._. 20 _ ,. I. BUILDING CODE: 2. ZONING: 3. SITE AREA: 4. BUILDING AREA: BUILDING AND SITE STATISTICS 5. CONSTRUCTION TYPE: 6. OCCUPANY GROUP: 1. AREA OF REMODEL: 8. PARKING: 9. PARKING SHOWN ON SITE: TAX ID. 188890 -0111 PROPERT' WNER: SURVEYOR: 2006 INTERNATIONAL BLDG. CODE (IBC) CL1 51,331 SF ( 1.18 AC. ) APPROX. 21,488 SF FIRST FLOOR I, 652 SF SECOND FLOOR V -B SPRINKLERED F -1 - FACTORY (FORMER MEAT PACKING) B - OFFICE (ACCESSORY USE) 8,000 S.F. ± FACTORY 6 1/1500 FOR 21,184 SF : 18 CARS' OFFICE 9 1/1000 FOR 5,930 ' SF : 6 CARS' SCOPE OF WORK: INSTALL UPRIGHT STEEL RACKING FOR PRODUCT STORAGE WITH SEISMIC TIE DOWNS, SEE STRUCTURAL. TOTAL READ. 24 CARS 31 STALLS (1 WC) PAUL PIGOTT C/O LA PANZANELLA 612 SO. ALASKA ST. SEATTLE, WA 98108 GEODATUM, INC. 1505 NW MALL STREET ISSAQUAH, WA 98021 (425) 831 -8083 LEGAL DE5c1RIPT THAT PORTION OF LOT 11 SOUTHCENTER SOUTH INDUSTRIAL PARK ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 91 OF PLATS, PAGES 22, 23, 24 AND 25, INCLUSIVE, RECORDS OF KING COUNTY, WASHINGTON DESCRIBED AS FOLLOWS: BEGINNING AT THE NORTHEAST CORNER OF SAID LOT 11± THENCE SOUTH 11 °23'50” WEST ALONG TI-4E EAST LINE OF SAID LOT II, A DISTANCE OF 19.42 FEET TO THE TRUE POINT OF BEGINNING± THENCE CONTINUING SOUTH 11 °23'50" WEST A DISTANCE OF 106.11 FEET± THENCE ALONG A CURVE TO TI-1E RIGHT HAVING A RADIUS OF 50.00 FEET, AN ARC DISTANCE OF 69.62 FEET THROUGH A CENTRAL ANGLE OF 19 °41'00 "± THENCE NORTH SS °49'10" WEST A DISTANCE OF 215.51 FEET± THENCE NORTH 15 °31'46" WEST A DISTANCE OF 66.01 FEET± THENCE ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 45928 FEET, AN ARC DISTANCE O 114.60 FEET THROUGH A CENTRAL ANGLE OF 14°11 THENCE NORTH 01 °19'58" WEST A DISTANCE OF 28.00 FEET± THENCE SOUTH 18°36'10" EAST A DISTANCE OF 328.25 FEET TO THE TRUE POINT OF BEGINNING. SITUATE IN COUNTY OF KING, STATE OF WASHINGTON co \� 0 M 0. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila PUIIl..D1Na S78 °36' 10 "E 328.26' PROJECT SITE 1 1"=20.00' So. 0 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal "l may include additional plan review fees. S0. 180th SO. 180th s• VICINITY MAP NOT TO SCALE Site Plan CORR LTR# c boLIs9 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 0 6 2009 PL City of T i!a BUILDING IVISION o ° d N LE COPY Plan review approval is subject to errors and tuntsslons. Approval n docu ents does not authorize the via tion of ar adopt +1 cO ► e or o inane. Receipt of ap Ted Fl C f, , and_ i~ t ion s acknowledged' Date: L1 City Of Tukwila BUILDING DIVISION RECEIVED OCT 23 2008 PERMIT CENTEF, Cr) rn CO 00 t� 0 am - N (0 (0 O 0 N N C° U) i- LA > Z, O (f) o!� Q Z W co l— 00 Z ~ (O Q O < 0) w Q- LL. .- Ma) ■ • 0 0 II O <4' LcD 00 sED =1 Z: \CAD \2008 \0804 LA PANZENELLA \RACK PLAN \SD- 1.dwg, 10/8/2008 9:02 :12 AM, Designiet 500 MAIN.pc3 SYM DATE DESCRIPTION PROJECT 09-25-0E3 SUBMIT FOR OWNER REVIEUJ DRAWN BY TERED 10-01-0E3 REV LAYOUT PER OWNER DK ARC-leT . 10-08-05 5USMIT FOR RACK PERI-11T DATE 09-25-0E3 DAVID E.. KE LE CHECKED BY STATEOF WA6141iGTON DATE OLYMPIC ACKI.AGING C MEANS OF EGRESS PATHWAY, MIN 44" IN WIDTH WITH LIGHTING AT +/- f4 I 1 I L_ _J 36' TRENCH DRAIN FINISHED GC1ODS 36 SPOTS FINISHED G 36 SPOTS EX. FAN EX. FAN INTAKE EX. I= o I I I — 0300 CFM 0 400 CFM O 3�0 CFM I SI- CURVED CONVEYOR 1 NEW PRODUCT STRAIGHT CONVEYOR 4' X 44.6' ION AND STOR, I I I I I I I L_J NEW OVERHEAD DOOR W/ 6" TUBE STEEL COL. OVEN LINE TWO CURRENT EX. PAIR OVERT -IEAD DOOR CRACKER 3'S" X -I' UCT I ON at 36' TRENCI -I DRAIN NEW' DOUGH RESTING TEMP CONTROL AND HUMIDITY NEW MIXIN NEW STORAGE NOTE I. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF I FOOT - CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT - CANDLE MEASURED ALONG THE P4714 OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0.6 FOOT- CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT - CANDLE AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO- MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO I SHALL NOT BE EXCEEDED. 2. EMERGANCY LIGHT FIXTURES TO HAVE BATTERY BACK UP TO TO MAINTAIN REQUIRED LIGHT LEVELS FOR A MINIMUM 90 MINUTES. 3. NE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL AT ALL TIMES THE BUILDING IS OCCUPIED BE ILLUMINATED. SEE FLOOR PLANS ON SHEET T -1. 4. VERIFY THAT THERE ARE ILLUMINTED EXIT SIGNS AT ALL REQUIRED EXITS. PATHWAY LIGHTING 4 BATTERY BACKUP INTERNAL ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING 4 BATTERY BACKUP R EVIEWED FOR E k CODE C P RO 1/ED � APP. JUL 0 6 2009 City of Tukwila BUILDING DIVISION SEW RACK PLAN SCALE: 1/8 " =1' -0" REV 4 -15 -08 REV 4 -23 -08 REV 07 -14 -08 REV 09 -25 -08 ADD RACKS REV 10 -01 -08 MOVE RACKS SINK STRUCTURAL NOTE: PROVIDE 2 - V1 dia. HILT! KB-17 ANCHORS ESR -1911 OR APPROVED EQUAL AT EACH FOOT PLATE. PROVIDE SPECIAL INSTPECTIONS PER IBC 1104 -13 AND I101k. RECE .W r. OCT 23 2000 PERMIT CEINTEF, o CD 00 N N w Z O Q EL w ErAd • 411 LC . 0 co •0 >z z O m 1- co F- CD Q V) CT) 0 = 1 RACKS \ \Wkst-4 \Documents \CAD \2008 \0804 LA PANZENELLA \RACK PLAN \T -1 RACKS.dwg, 10/23/2008 1:49:32 PM, DesignJet 500 MAIN.pc3 1 1 1- 0 fY w 0 > cii N 1 J_ ACKI.AGING C MEANS OF EGRESS PATHWAY, MIN 44" IN WIDTH WITH LIGHTING AT +/- f4 I 1 I L_ _J 36' TRENCH DRAIN FINISHED GC1ODS 36 SPOTS FINISHED G 36 SPOTS EX. FAN EX. FAN INTAKE EX. I= o I I I — 0300 CFM 0 400 CFM O 3�0 CFM I SI- CURVED CONVEYOR 1 NEW PRODUCT STRAIGHT CONVEYOR 4' X 44.6' ION AND STOR, I I I I I I I L_J NEW OVERHEAD DOOR W/ 6" TUBE STEEL COL. OVEN LINE TWO CURRENT EX. PAIR OVERT -IEAD DOOR CRACKER 3'S" X -I' UCT I ON at 36' TRENCI -I DRAIN NEW' DOUGH RESTING TEMP CONTROL AND HUMIDITY NEW MIXIN NEW STORAGE NOTE I. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF I FOOT - CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT - CANDLE MEASURED ALONG THE P4714 OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0.6 FOOT- CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT - CANDLE AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM -TO- MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO I SHALL NOT BE EXCEEDED. 2. EMERGANCY LIGHT FIXTURES TO HAVE BATTERY BACK UP TO TO MAINTAIN REQUIRED LIGHT LEVELS FOR A MINIMUM 90 MINUTES. 3. NE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL AT ALL TIMES THE BUILDING IS OCCUPIED BE ILLUMINATED. SEE FLOOR PLANS ON SHEET T -1. 4. VERIFY THAT THERE ARE ILLUMINTED EXIT SIGNS AT ALL REQUIRED EXITS. PATHWAY LIGHTING 4 BATTERY BACKUP INTERNAL ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING 4 BATTERY BACKUP R EVIEWED FOR E k CODE C P RO 1/ED � APP. JUL 0 6 2009 City of Tukwila BUILDING DIVISION SEW RACK PLAN SCALE: 1/8 " =1' -0" REV 4 -15 -08 REV 4 -23 -08 REV 07 -14 -08 REV 09 -25 -08 ADD RACKS REV 10 -01 -08 MOVE RACKS SINK STRUCTURAL NOTE: PROVIDE 2 - V1 dia. HILT! KB-17 ANCHORS ESR -1911 OR APPROVED EQUAL AT EACH FOOT PLATE. PROVIDE SPECIAL INSTPECTIONS PER IBC 1104 -13 AND I101k. RECE .W r. OCT 23 2000 PERMIT CEINTEF, o CD 00 N N w Z O Q EL w ErAd • 411 LC . 0 co •0 >z z O m 1- co F- CD Q V) CT) 0 = 1 RACKS \ \Wkst-4 \Documents \CAD \2008 \0804 LA PANZENELLA \RACK PLAN \T -1 RACKS.dwg, 10/23/2008 1:49:32 PM, DesignJet 500 MAIN.pc3 BEAM,. CONNECTION GENERAL: CONFIGURATION 3 ROW SPACER BOTH SIDES 1 TYP. 7/i s "o RIVET ASTM A354 -79 t =0.06" t 3/16" (2)-1/2"0 ANCHOR BOLTS PER BASE PLATE 3 1/4" EMB., (SEE NOTE NO. 4) RACK DESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE +r204, GLENDALE, CA. 91204 SCALE: NONE DATE: 19 -9 -08 REVISION LAPANZAN ELLA 18475 OLYMPIC AVE. TUKWILLA, WA. 98188 DRAWN BY: A.KH. 144" do 94" FRONT VIEW SIDE VIEW • 4 • . • • • • 4 .. '4 A •••••• . • � •• • A • • b � . '. .. • • I • A . • . • • • • • t• • 4 a go �� -.- EXPIRES 12- 26''09 0 0 r VIEWE D F :i E COMPLIANCE PPROVED f G. 0 6 2009 y o f Tukwila ING DIVISION , STORAGE RACK DETAILS Mak 1- DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2006 EDITION 2 -STEEL FOR ALL SHAPES FY =55 KSI. ASTM A570 -85 GR.55 (EXCEPT AS NOTED) 3 -ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES) 4 -ALL ANCHORS HILTI KB -TZ ESR -1917 OR APPROVED EQUAL 5- CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6- STORAGE RACK CAPACITY 3500 #/ LEVEL 7 -ALL RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD OF 3500 #/ LEVEL 8- STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10' -0" OF HEIGHT RECEW'VEr OCT 2 3 2008 PERMIT CENTEt JOB NO. RD -13692 SHEET NO. 1 OF 1 I IMPORTANT In localities subject to freezing conditions, it is the owners responsibility to provide heat throughout wet pipe sprinkler systems areas and in enclosures for dry pipe deluge and other types of valves controlling water supplies to sprinkler systems. This drawing and the information and design application herein contained is the property of TYCO FIRE & SECURITY SimplexGrinnell and/or its p p y p subsidiaries and is loaned upon express conditions that the same be returned to SimplexGrinnell upon request; all information herein contained shall be treated as secret, and confidential; no reproduction of this drawing or any part thereof shall be made without written consent of SimplexGrinnell. Created by the SimplexGrinnell "All rights reserved ". ` Copyright by SimplexGrinnell 2005 CONTRACT RESPONSIBILITIES ITEM SimplexGrinnell/BY OTHERS SYMBOLS I I Hydraulic Reference Point - - Flow Switch (FS) Gate Valve - N.R.S. (CV) Fire Dept.Conn.(FDC) - (yam OS &Y Gate Valve (oS & Y) Post Indicator Valve (PIV) B Monitor switch x24 Fire Hydrant (3 Way) Line Deal nation rl Butterfly Valve _1, Thrust Block 1 g t-► ►Earthquake Bracing M AKE TYPE MODEL SIN NPT SPRINKLERS K FACTOR TEMP. FINISH ESCUTCHEON NOTES SYMBOL QTY. REM• AREA NAME NO. HYDRAULIC HAZARD CLASSIFICATION DENSITY GPM /SQ.FT. DESIGN AREA OF APPUC. HOSE ALLOW. DATA S Q. FT . /HD. TOTAL GPM SYSTEM PSI REQUI REMENTS AT ABBREVIATIONS AC -Above Finished Ceiling A FF - Above Finished Floor BC - Below Finished Ceiling Boe - Bottom of Beam BOD - Bottom of Deck BO J - Bottom of Joist BOP - Bottom of Purlin HV -Hoee Valve N - Not in Co NTS - Not to Scale OBJ -Open SP - standpipe T OB -Top of Bar Beam TOP - Top of Purlin TOS - Top of Steel UON - Unless Otherwise Noted WET SYSTEM TYPE SPECIAL REQUIREMENTS ❑ DOMESTIC PIPE ❑ SCHEDULE 40 ❑ SCHEDULE eo ❑ GALVANIZED PIPE ❑ GALVANIZED FiTTiNGs ❑ GALVANIZED MATERIALS SPECIAL FITTINGS ❑ F.M. MATERIAL ❑ OTHER J 0 DELUGE _❑ DRY ❑ PREACiION STREET WATER CONNECTION N/A TYCO UPRIGHT ELO -231 TY5111 11 286 BRASS WRENC W TYPE 3 225 _❑ UNDERGROUND WATER MAINS N/A EX HAZARD 0.60 2042 500 98.7 2094.9 85.5 SUPPLY ❑ qTY �fl, ❑ FM ❑ APPROVALS 2 EXTRA HAZARD 0.60 20 42 500 98 2439 93 . SUPPLY SUPPLY EXCAVATIONS N A / I -/- Hanger Alarm Valve (ALV) Ke y Gate Sectional Valve w ith Roadway B ox BACKFILL N/A WIRING N/A A Main Designation U nion g - °l, - gElectrlc Bell q OUT IN screwed Cap Fire Hoee Assembly o® * Grooved Cap $ Water Motor Gong (WMG) 13 ¢ of Pipe Below Bott of Deck -- 11) p -DI Wafer Check Valve -� Inspectors Test -- Screwed Plug +12' - of Pipe Above Ref. Plane _0_ Grooved Coupling -N- Swing Check Valve -5- Globe Valve Fire Dept.Conn.(Standard)(FDC) Angle Valve Elevation Chan a in Pipe -a- Flanged Connection - -� P AINTING N A / OUT IN WATER SUPPLY INFORMATION. STATIC PRESSURE RESIDUAL PRESSURE 1 50 PSI 20 PSI. WITH 4683 tp� FLOY1NG OUT IN TEST LOCATION: OLYMPIC AVE S. ®S. GLACIER ST. (LOW) C (HIGH) OUT IN (not thru floor) � ® System Riser Fire Dept.Conn.(Flush) (FDC) Dry Pipe Valve - TOTAL THIS SHEET - 225 BY: TUKWVILA PUBLIC WORKS TEST DATE: 03-11-09 A C D E F G H 1 I 2 I 3 I. r t `24/ \ 6 j (32 j Tk Tk Q b Q REMOTE AREA 2 (). b C65 2 v A 2 . 2 A v 2 ,.. s, _�8 - _S_- .__._.._7_ � L7>, 4 f�7 3-� =' L N . % 0-6 ( 6s # ) 47) X101) � ,I 0-4 �, 64 JJ �I DA ti ;AI oa I (27 I \ 33 / I I t . ' 4 /56 - ' 4- I ±1.-1 .1 % : 57 L- -6-0-- 6-0 2. ......1. �1 - . -__ -4 \ 25� - N is I d X 28) I ( ' 4 ) I - � 63 IM t1) \ --' '. m 42 / 0 ,7 it N / \ 23'7 "AFF 103 A NI 1 BOD 1 #2 I P 10-4 23'7"AFF ~ i RI - I ^ ( 62 . 'I 0 1'4 # 1 �v 1 # 2 Lu X4 / 'I y'L 61 \ T 1 an N ° . '- 011-4 'I ( B5 y ,ti 7 - N N 914 2 R',"S .4 5 1 -111- 76 7 :0 - 0 5 - " 8-0 6K 10-4 B4)_2c8„,1 5 -8 ' � 46 l - 0-6. 62 __)( B3 5R 4 / 5 1 10-4 2-0 N I 3`'.A 7 d ✓ o b 6 r- e- REMOTE AREA 2 REMOTE AREA 1 3 9- 9- L 112 6-0 ' 23'7 "AFF �5 �NI p 1'4 "BOO 1 -8 3 Q N , ; 1"(t:: > N1 :14616 X45 I 0 3 I ■ I (\_44:/ 1 31 10-4 c - 9 9 _ b * :`J r REMOTE AREA 1 DRAIN r.� (102 104 i # A SKYLIGHT REMOTE AREA 2 N 1 4 66 " 0-6 \ B6) w�1 6 G r a 8 2 -1 i i NI b NI (10 I X 16 .� 1 3 l_°b - a, - 1 -12" HOSE VALVE PC =ME 11111.191= I 14 6-� 1 0-4 N 23'7 "AFF V• N I C -r°1, I 23'7 AFF I 14B OD b I 23'7 "AFF ' 146 ` -- -- -( \ A6/ LI NI 'o , 3 I b 23'7"AFF 148 6 7 A: . ROTE IgREA 1 23 > • `- NI I A 22/ I 0 i 13 NI CD I°b \ I 21) 6�b REMOTE AREA 1 6 8 NOT TO SCALE NOTE: THE OVER-HEAD SPRINKLER SYSTEM iS EXISTING. FOR iNSTALLAT'ION OF TENANT iMPPOVEMENT UJOPK ONLY. 9 r 4 1 I ct 1 1 0 1 1 I I 23''rAFF I 14 800 N. .r f4. 0 8 -c . 1 I 4- �I 1 I i 4 1 0 I1 1 3 1 T ---- N I 1 6- SAMMY SUPER SCREW III -21211 PIPE: GST 20 1 311 -411 PIPE: GST 30 yl 12 -4 Q NI 23'7 "AFF 1'4"BOD 23'YAFF 1 4 B N '" I,jnjy 8 4 1•- IANGER #1 - SAMMY SCREW, ROD $ RING I 2STAFF .. 1'4 "BOD I^ „ , IN b rL,�,'S 8 1 -6 L. _ 1 r�• .- 13-10 1 -712 I N �I 24'AFF 9BD NI I 0 I ( ; )1 1 1 �I a 23'7"AFF 14BOD NI 6- ALL THREAD ROD 10 +10 1 -12" H ISE VALVE 5-8 ADJUSTABLE RING HANGER NI O I 23'7 "AFF 23'7"AFF I 14 BOD 14 BOD 7 , M1 �� 8 23'7 "AFF 1'4 "60D 12 -4 5 FIRE SPRINKLER PIPING PLAN SCALE V8' • 1 -0 0 2' 4' 8' 16' (1111 I GRAPHIC SCALE r a 01 11.1- 31 _,- ;LI 16 1 I NI O 1 11 23'rAFF 1'4 "BOD I I^ 1 N�9 8 1' 8 d 19 o N C W) a•h co 6 -� 22'2 "AFF 4'9 "BOD 8 F- F- ^ SAMMY SIDEWINDER I -4 PIPE: SWDR kA W/ RETAINING NUT NI O 6- STRUCTURAL STEEL ALL THREAD ROD ADJUSTABLE RING HANGER 23'7"AFF 1'4 "BOD � � 8 NI NI CD 1 23'7"AFF 11480 6 23'7 "AFF NI r.. 141300 'I I^ V I I I 23'7 "AFF I 148 N w Z 8 10 4. 60 1 -12-4-- - 1 4 I 0 I �I b 6- a 12{-4 MANGER #2 SAMMY SIDEWINDER, ROD $ RING NOT TO SCALE 23'7 "AFF NI 14 BOD • - I r' N � N 1 1. 1, 3 OI l:J - b NI O 8 12 -4 7 I 23'7"AFF N 1'4 "BOO •�_'I I b I 1� NI rL,,� 0 al X :I,�. 1 • O 1 00 I 13 I 1 i I ▪ b I I I - 23'7 "AFF 1 23'7"AFF 11'4 I1'4BOO pA N 6 6 - 12 -4 4 NI ; (I Y 1 N I s (;) 23'7 "AFF 141460 7_1 I 23'7'AFF I 14 BOO v �I AJSLI,�,'S 6 8 (;) I 23'7'AFF s 1'4 "BOD N I ^ 5 5 -_ F24 .__.._ 10- 4 _ 1 N NI I I 23'7"AFF I 1'4 N I ��M1 7- I , j I 7-Tit 6- 5 -11 -4 EXISTING PIPE: NEW PIPE: X X X - X ADDED UPRIGHT SPRINKLER: REPLACE UPRIGHT SPRINKLER: O 0 2 7 "AFF I ' 1 BOD I^ I (I P � 7-2 1:1 FIRE SPRINKLER LEGEND 7i, NI 0 9 vulluy Ptldva taath It I 4.titt 74i mot st 19 4 si lb V40eit dr Ronton nst Ottt rat WO vital ill AK* I* rasoft OWNER / OCCUPANT LA PANZANELLA 18475 OLYMPIC AvENUE SOUTH SITE CONTACT: RON HACKER 425-318-2410 VICINITY MAP NOT TO SCALE Remote Area 1 Wet / Dry Hazard Code Construction WET EXTRA HAZARD NFPA 13 FLAMMABLE PSI Avail at Source 119.2 PSI Req'd at Source 85.5 Safety PSI 33.7 Flowing Heads 23 Density 0.60 Area 2042 Len/Wid Ratio 1.2 Max Velocity 35.8 Source Name or Location CITY SUPPLY OLYMPIC AVE S Start Head PSI 28.0 Start Head GPM 59.2 SQFT per Head 98.7 Elev-lid to Riser (") PSI -Hd to Riser GPM Req'd at Source 2094.9 lInside Hose X Duration of Source 120 Outside Hose 500 Req'd Source Volume X NOTES: Design: 0.60/ 2000 sq.ft. NFPA-13 (2007) 17.2.1.2(d) sub-note 2 - Ceiling only protection shall not be permitted for this storage configuration except where K-11.2, K-14, or K-16.8 spray sprinklers listed for storage use are installed. In-rack sprinklers shall not be required, provided the ceiling sprinkler discharige criterion is increased to 0.6 gpm/ft sq over 2000 ft sq and the ceiling height in the protected area does not exceed 27 ft. 10 1 REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION GENERAL DESCRIPTION/DESIGN REQUIREMENTS EXTRA HAZARD, GROUP A PLASTICS, STABLE, COMMODITY CLASS STORAGE - 19560 SQ. FT SOURCE OF WATER SUPPLY TUKWILA PUBLIC WORKS 1 TEST LOCATION - OLYMPIC AVE S. & S. GLACIER ST. 2 12" WATER MAIN GROUND ELEVATION 20' 3 STATIC PRESSURE 150 PSI 4 RESIDUAL PRESSURE 20 PSI 5 FLOW CAPACITY 4563 GPM 6 TEST PERFORMED BY TUKWILA PUBLIC WORKS 7 TEST PERFORMED 03-11-09 SCOPE ADD (6), REPLACE (219) SPRINKLERS WITH 11.2K FACTOR SPRINKLERS FOR EXTRA HAZARD STORAGE AREA IN AccORDANCE WITH N.F.P.A. 13-2007 EDITION AND THE REQUIREMENTS OF CITY OF TUKWILA FIRE DEPARTMENT. GENERAL NOTES 1 SPRINKLER SYSTEM DESIGN PER N.F.P.A. ii13 2 ALL MATERIALS SHALL BE NEW AND UL AND/OR F.M. APPROVED 3 FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH N.F.P.A. #13 4 IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE owNERs RESPONSIBILITY TO PROVIDE HEAT THROUGHOUT THE WEY PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS 5 FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF 6 ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS 7 SPRINKLERS sHALL BE INSTALLED AT LEAST 4" FROM EDGE OF CEILING TILES 8 ALL DIMENSIONS ON PIPING ARE CENTER TO CENTER FOR SUBMITTAL DRAWINGS 9 ALL DIMENSIONS ON PIPING ARE CUT LENGTHS FOR INSTALLATION DRAWINGS 20FT MAXIMUM RACK STORAGE WITH 5 TO 10 FT CLEARANCE TO CEILING 0.60 GPM/2000 SQ FT W/ CEILING SPRINKLERS REPLACED WITH 11.2K FACTOR SPRINKLERS ACCORDING TO NFPA 13 2007 17.2.1.2(d) SUB-NOTE 2. Remote Area 2 Flowing Heads 29 Wet / Dry WET Hazard EXTRA HAZARD Code NFPA 13 Construction FLAMMABLE Density 0.60 Area 2042 Len/Wid Ratio 1.2 Max Velocity 40.4 Start Head PSI 27.7 Start Head GPM 58.9 SQFT per Head 98.7 Elev-Hd to Riser (") PSI -Hd tO Riser Source Name or Location CITY SUPPLY OLYMPIC AVE S PSI Avail at Source 109.2 GPM Reg'd at Source 2439.2 lInside Hose X PSI Req'd at Source 93.8 Duration of Source 120 Outside Hose 500 Safety PSI 15.4 Req'd Source Volume X NOTES: Design: 0.60/ 2000 sq.ft. NFPA-13 (2007) 17.2.1.2(d) sub-note 2 - Ceiling only protection shall not be permitted for this storage configuration except where K-11.2, K-14, or K-16.8 spray sprinklers listed for storage use are installed. In-rack sprinklers shall not be required, provided the ceiling sprinkler discharsge criterion is increased to 0.6 gpm/ft sq over 2000 ft sq and the ceiling height in the protected area does not exceed 27 ft. CORRECTION po LTR# 11 RECEIVED CITY OF TUKVVILA JUN 2 3 2009 PERMITCENTER I- 12 m Lu Ci co 0 CO c co 0) Lo CD CD 0 CD rraM c cv -t4 rx1 rn ce 0 _J Z .„W CL ii*k t SCALE: AS NOTED DRAWN BY: CHECKED BY: ALAN MAHAFFIE DATE: 05 14-09 CONTRACT NUMBER: SHEET NUMBER: FP-1 SHEET 1 OF 1 ce 0 a CJI 12 A