Loading...
HomeMy WebLinkAboutPermit D08-477 - CITY OF TUKWILA - NORTHFIELD CARWASH - DEMOLITIONNORTHFIELD CARWASH DEMOLITION 14224 TUKWILA INTERNATIONAL BL D08 -477 CRAW Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1523049096 Permit Number: D08 -477 Address: 14224 TUKWILA INTERNATIONAL BL TUKW Issue Date: 02/19/2009 Suite No: Permit Expires On: 08/18/2009 Tenant: Name: NORTHFIELD CARWASH DEMO Address: 14224 TUKWILA INTERNATIONAL BL , TUKWILA WA Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKWILA WA 98188 Phone: DEVELOPMENT PERMIT Contact Person: Name: MIKE CUSICK Address: 6300 SOUTHCENTER BL, STE 100 , TUKWILA WA 98188 Phone: 206 431 -2441 Contractor: Name: PACIFIC NW EARTHWORKS LLC Address: PO BOX 351 , FALL CITY WA 98024 Phone: (425)222 -0874 Contractor License No: PACIFNE943LE Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 $40,000.00 * * continued on next page ** Expiration Date: 07/05/2010 DESCRIPTION OF WORK: DEMOLITION OF 1260 SF BUILDING. PROJECT ON VALLEY VIEW SEWER AND WATER DISTRICT #125 WATER. PUBLIC WORKS ACTIVITIES INCLUDE EROSION CONTROL , SEWER CAPPING, REMOVAL OF 0/W SEPARATOR. Fees Collected: $1,754.55 International Building Code Edition: 2006 Occupancy per IBC: D08 -477 Printed: 02 -19 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: doc: IBC -10/06 City oiTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Y N Private: Public: Profit: N Non - Profit: N Private: Public: Permit Number: D08 -477 Issue Date: 02/19/2009 Permit Expires On: 08/18/2009 Date: 04M/09 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli- • -, -they specified herein or not. The granting of this • t does not presume • give authority to violate or cancel the provisions of any other state or local laws regulating construction or t •erformance of work. authorized to sign and obtain this development permit. Date: O4 /bQ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -477 Printed: 02 -19 -2009 Parcel No.: 1523049096 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14224 TUKWILA INTERNATIONAL BL TUKW NORTHFIELD CARWASH DEMO 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: D08 -477 ISSUED 10/23/2008 02/19/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 8: The applicant must notify the City Project Inspector at (206)433 -0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 9: Any material spilled onto any street shall be cleaned up immediately. 10: Temporary erosion control measures shall be implemented as the first order of business to prevent sedimentation off-site or into existing drainage facilities. 11: The site shall have permanent erosion control measures in place as soon as possible after final grading has been completed and prior to the Final Inspection. 12: Applicant shall coordinate with Valley View Sewer District for the location of the sewer stub serving the carwash. 13: The oil/water separator tank shall be removed and the area shall be backfilled with 5/8 crushed top course flush with existing pavement. doc: Cond -10/06 * * continued on next page ** D08 -477 Printed: 02 -19 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit not presu construction or the pe . o ance of work Signature: Print N • - : fit' ///-11 S C2 doc: Cond -10106 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us to give authority to violate or cancel the provision of any other work or local laws regulating Date: Z /a D08 -477 Printed: 02 -19 -2009 SITE LOCATION Site Address: Tenant Name: Property Owners Name: C I Mailing Address: (.• . 00 ...504./711 C 7�-yti Name: ( - ko CITY OF TUKWII Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwcitukwila.wa.us 1424 i.1 13 d'Ilh ( ?(Vt.'usllTh-- 1 7 f w 'L 4 t C3Gu Mailing Address: Sv f we> E -Mail Address: Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Company Name: C i T I T?/!C w 1 L 4 Mailing Address: C 3C•c C9t Contact Person: "ii `� � e.sr c 4 r E -Mail Address: Sa 'r»CC".:m -{ Q: \Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh 13 - v12 Building Peri1..c No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** King Co Assessor's Tax No.: Suite Number: New Tenant: / 3 (t 4 (- j4 State City 901 (Fur of,ice use only) f523D4 g 242 D/ Floor: .... Yes ..No j 2,1 Zip Day Telephone: 2 Qi zi 3/ ° 2 yy / City State Zip Fax Number: 20C — 3(.65- GENERAL CONTRACTOR INFORMATION — (Contractor Informat for Mechanical (pg 4) fo Plu tubing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State State 13 L., / 00 174 /c4 4. City State Zip be w ARCHITECT" OF 1 stamped by Ar Company Name: Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD : All plans c t be Wet stamped by Engn Zip Day Telephone: 5,097'"L C Fax Number: Page 1 of 6 BUILDING PERMIT INFORITION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ 'r Jl/ GUG Existing Building Valuation: $ Scope of Work (please provide detailed information): 7 � r o A424 Pi r 16"-c-ro 0.4-r Will there be new rack storage? ❑.... Yes Number of Parking Stalls Provided: Standard: Q:\Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below 1" Floor Floo. Floors Basement Accessory Structure Attache Garage Detached Garage Attached Carport ;ached Carport Covered Deck Uncovered Deck Addition to Existing Structure Type of Construction per IB+C Type of Occupancy per IBC PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOT Applicable to all permits in this ap . 'cation Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY HE Lam, S OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 HORIZED AGENT: Signature. Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). be- G> s/c e Mailing Address: Ci :300 ,.sean1Ct — TL-- M'vlln Date Application Accepted: Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Date: 4 /23% 0 Day Telephone: ?a- 4/3/ — 2 qt. f3[ l/0 7Z/4 State Zip Staff Initials: j-- Date Application Expires: 014 1,1,291 i Page 6 of 6 Fixture Type: Qty Fixture Type: sty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or wat cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder commercial Receptor, indirect aste Clothes washer, domestic Floor drain ks Dental unit, cuspidor Shower, sin: ead trap U ' als Dishwasher, domestic, with independent drain Lavatory Wat- Closet Building sewer or trailer park sewer Rain :ter system — per dra' (inside building) Water .ter and /or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors ' • air or alteration of water 'Ting and /or water treating equipment Repair or a - ration of drainage • vent piping Medical gas piping system serving one to five inlets /outlets for specific gas ( PLUMBING AND GAS PIPIN ERMIT INFORMATION - 206 - 431 J70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration ' umber: Valuation of Plumbing work (c, tractor's bid price): $ Valuation of Gas Piping work (co • actor's bid price): $ Scope of Work (please provide detai • information): Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlet Q: 1Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: Expiration Date: installed and the quantity below: State Z ip Page 5 of 6 Receipt No.: R09 -00288 Initials: LAW User ID: 1632 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1523049096 Permit Number: D08 -477 Address: 14224 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 10/23/2008 Applicant: NORTHFIELD CARWASH DEMO Issue Date: Payee: PUBLIC WORKS ACCT 302.00.594.190.41.01 TRANSACTION LIST: Type Method Descriptio Amount Payment Other 600.00 ACCOUNT ITEM LIST: Description PW BASE APPLICATION FEE PW PERMIT /INSPECTION FEE PW PLAN REVIEW Account Code Current Pmts 000/322.100 000/342.400 000/345.830 (00'009)$ sP'i J . - snid .5 4iwiej 037 RECEIPT Total: $600.00 00905101 -1 0024 02/20/2009 001 101 DCD Permits Plus - General Fund $600.00 Payment Amount: $600.00 Payment Date: 02/19/2009 02:01 PM Balance: $0.00 250.00 175.00 175.00 doc: Receiot -06 t �J t l ULI 6:00Z706/ 101060 Printed: 02 -19 -2009 Parcel No.: 1523049096 Permit Number: D08 -477 Address: 14224 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/23/2008 Applicant: NORTHFIELD CARWASH DEMO Issue Date: Receipt No.: R08 -03596 Initials: JEM User ID: 1165 Payee: PUBLIC WORKS ACCT 302.00.594.190.41.01 TRANSACTION LIST: Type Method Descriptio Amount Payment Other 1,154.55 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $1,154.55 Payment Date: 10/23/2008 01:44 PM Balance: $0.00 697.00 453.05 4.50 Total: $1,154.55 doc: Receiot -06 Printed: 10 -23 -2008 Project: _,_{ c ! nn �� 0h1 fr\ rr e_16 cArwA-SC\ Type of Inspection: `` gv � �'l tle A Address: 14/OA . S Date ai d: Special Instructions: o3 '� 00 �Q1 L 3 (1.. .._. Date Wanted: / _ 0 1 ( m. �pm. Requester: Phone 6 ....4 8 1 z44) INSPECTION RECORD Retain a copy with permit vF1 -477 1 �� U�1 PERMRN . PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 lived per applicable codes. Corrections required prior to approval. COMMENTS: ri $60.00 REINSPECTION FEE RE IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., ite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: Der 0 / clike 6,,. W Type of Inspection: r,,..44 . (--- Address: ,r22q T Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: F Inspector /' Q ✓S'v lDat G7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: =. ` s - s - elaNe.A.ya.• *:S�h� PBS October 15, 2008 Engineering + Environmental Mr. Michael Cusick City of Tukwila Public Works Department 6300 Southcenter Boulevard Tukwila, WA 98188 RE: 14224 Tukwila International Boulevard (Northfield Car Wash) Asbestos - Containing Materials and Lead Paint Survey PBS Project No. 40407.012 ECE$V CITY R OF TU ' LA OCT 2 3 2008 PERMIT CENTER Dear Mr. Cusick: PBS Engineering + Environmental (PBS) performed an inspection of the former Northfield Car Wash at 14224 Tukwila International Boulevard in Tukwila, Washington for the presence of asbestos - containing materials (ACMs) and lead- containing paint (LCP). According to your information, this project is in conjunction with a proposed demolition of the site structure. The site structure is a one -story concrete block building with eight car wash bays built on a concrete slab. The structure contains a total of approximately 1,260 square feet. The car wash has recently been taken out of operation. Interior concrete slab floor. The roof is corrugated exposed et metal over a barrier of s � plywood ceilings, and conc polyethylene sheeting. Asbestos - Containing Materials (ACM) The intent of this letter is to ensure that the City of Tukwila Public Works Department is in compliance with the Puget Sound Clean Air Agency and Washington State Department of Labor and Industries' requirement that a "good faith" inspection for ACM be performed prior to renovation or demolition activities. While PBS has endeavored to identify all ACM, unidentified ACM may exist in concealed or inaccessible locations. Inaccessible areas-are defined as those requiring selective demolition, fall protection or confined -space entry protocols to gain access. PBS recommends that concealed components and materials be sampled for asbestos prior to impact. Suspect materials were sampled on October 8, 2008 by AHERA- accredited Inspector, Janet Murphy (Certification #129790, exp. June /18/09). Samples were assigned unique identification numbers and analyzed according ord Laboratories, (NVLAP using were g Polari ed Light Microscopy (PLM), which has a analyzed according to EPA Method limit of quantification of 1% asbestos by volume. Bend I Boise I Coquille I Eugene I Portland I Seattle I Tri•Cities I Vancouver 2517 Eastlake Avenue East, Suite 100, Seattle, A 8102 206.762.4780 Fax www.pbsenv.com 4114- Mr. Michael Cusick City of Tukwila Public Works Department Asbestos and Lead Paint Survey of 14224 Tukwila International Boulevard The attached bulk sample chain -of- custody forms identify tto contain asbestos during PBS b y materials that were PBS and analyzed for asbestos. The following materia ls were found survey: • No materials sampled were found to contain asbestos The following materials in which laboratory analysis detected no asbestos include the following: • Sealant on electrical mast on roof • Brick Mortar • Door sealant • Insulation on pipes and conduits • Rockwooi insulation with paper • Fiberglass insulation with paper • Wire insulation • Gypsum board Lead - Containing Paint (LCP) Representative painted coatings were sampled and analyzed o determine a lead content. determine the extent samples of were analyzed by Atomic Absorption Lead Analysis for total LCP in the substrate. Ten (10) paint chip samples were collected from representative substrates and analyzed. Lead was detected in concentrations above the lyti contain limitn of lead coot in eight of the pa chips samples analyzed. The following building P on • Green paint on the fascia board around the exterior trim (0.087% -0.23 %) • White paint over the exterior concrete block wall (0.016 %) • Blue paint on exterior doors (0.40%) • White paint on exterior door jam (<0.0036%) • Yellow on the ceiling of the storage room ( <0.0084 %) • White on the ceiling in the car wash bays (0.020 %) No lead was detected above laboratory detection limits in the white painted exterior door jam or the yellow painted storage room ceiling. The green paint on the exterior fascia is in poor con ure are in relatively good condition Based on the subsurface. The other painted surfaces in the structure results of representative coatings, it may be assumed that all similar coatings on building materials within the project site contain lead. See attached laboratory analysis report. painted presence d in of lead in ainted coatings requires construction work to be pe f orme aint and pliiances with State and Federal regulations. Employers of personnel impacting lead- con ertraining, res iratory are required to perform a negative exposure as outlined in WAC 296155 vide proper P protection and medical surveillance Mr. Michael Cusick City of Tukwila Public Works Department Asbestos and Lead Paint Survey of 14224 Tukwila International Boulevard Based on lead concentrations detected to date, it is not anticipated that demolition debris will require disposal as "dangerous" per WAC 173 -303, Dangerous Waste Regulations. However, waste stream characterization for lead by TCLP analysis should be performed by the contractor prior to construction debris disposal. Respectfully, Harry Goren Project Manager AHERA Building Inspector Certification #1027762, expiration 2/6 /2009 Attachments PLM Laboratory Reports and Chain - Custody Lead paint Laboratory Reports and Chain -of- Custody Janet Murphy AHERA Building Inspector Certification #129790, exp. June /18/09 AIHA Environmental Lead & Industrial HYgiene See afNSIgap.org for details NVL LAB0RAT0RIS. INC 4706 AURORA AVE N SEATTLE. WA 98103.6516 TEL 306.517.0100 FAX 206.834.1936 nvlIabsll evil abs.Com October 9. 2008 Harry Goren PBS Environmental (Seattle) 2517 Eastlake Ave E, Suite 100 Seattle, WA 98102 RE: Bulk Asbestos Fiber Analysis, NVL Batch # 2812872.00 Dear Mr. Goren, Sincerely, Ni 'cal Director NVLAP Lab Code 102063 -0 Enc.: Sample Results 112LARD001 MM8111614L7 ,AANACEAIENT • TRAINING • Lan SERVICES INVILM L A B S HAZARDOUS M A T E R I A L S S E R V I C E S Enclosed please find test results for the bulk samples submitted to our laboratory for analysis. Examination of these samples was conducted for the presence of identifiable asbestos fibers using polarized light microscopy (PLM) with dispersion staining in . accordance with U.S. EPAI600/R- 93/116 Test Method. For samples: containing more than one separable layer of materials, the report will include findings for each layer (labeled Layer 1 and Layer 2, etc. for each individual layer). The asbestos concentration in the sample is determined by visual estimation. For those samples with asbestos concentrations between 1 and 10 percent based on visual estimation, the EPA recommends a procedure known as point counting (NESHAPS, 40 CFR Part 61). Point counting is a statistically more accurate means of quantification for samples with low ,concentrations of asbestos. If you would like us to further refine the concentration estimates of asbestos in these samples using point counting, please .let me know. This report is considered highly confidential and will not be released without your approval. Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks. Thank you for using our laboratory services. Please do not hesitate to call if there is anything further we can assist you with. WWW.nvllabs.com 1.888.NVL.LABS (683.5227) NVL Laboratories Inc. 4708 Aurora Ave. N., Seattle, WA 98103 Tel: 206.547.0100,�vl F 206 634.1936 10 For the scope of accreditation under NVLAP Lab Code 102063 - Client: PBS Environmental (Seattle) Address: 2517 Eastlake Ave E, Suite 100 Seattle, WA 98102 Attention: Mr. Harry Goren Project Location: Northfield Car Wash Bulk Asbestos Fibers Anal sis By Polarized Light Microscopy Batch #: 2812872.00 Client Project #: 40407.012 Date Received: 10/08/2008 Samples Received: 8 Samples Analyzed: 8 Method: EPA1600R- 93/116 Lab ID: 28082175 Client Sample #: 1 Location: Northfield Car Wash Layer 1 of 1 Description: Off -white soft material Other Fibrous Materials:% Non - Fibrous Materials: None Detected ND Binder /Filler Lab ID: 28082176 Client Sample #: 2 Location: Northfield Car Wash Layer 1 of 1 Description: Off-white hard brittle material r Fibrous Materials:% Other Materials: None Detected ND Fine particles, Binder /Filler, Mineral grains Lab ID: 28082177 Client Sample #: 3 Location: Northfield Car Wash Layer 1 of 1 Description: Off -white soft material with paint Non- Fibrous Materials: Fine particles, Binder /Filler, Paint Lab ID: 28082178 Client Sample #:.4 Location: Northfield Car Wash Layer 1 of 1 Description: Black soft material Non- Fibrous Materials: Synthetic/Binder Lab ID: 28082179 Client Sample #: 5 Location: Northfield Car Wash Layer 1 of 2 Description: Tan fibrous material with black asphaltic sphalttiii . mah Fibrous Materials' /o Asbestos Type: Non = Fibrous Materials: Cellulose 55% None Detected ND Fine particles, Asphalt/Binder,.Mastic/Binder, Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND Other Fibrous Materials:% Asbestos Type: % None Detected ND •None Detected ND Other Fibrous Materials:% Asbestos Type: None Detected ND None Detected ND Sampled by: Client Tory s azhnyuk Date: 10 /09/2008 i.��� Analyzed by: Nadezhda Pry Y , Reviewed by: Nick Ly Date: 10 /09/2008 Nick e . Islimited sam tes are not homogeneous,. then subsamples of the components were analyzed separately. All bulk samples analyzed using EPA 6001 Note: If p measurement uncertainties for reported of th -60%). This report relates on ly to Method with the folln to the re orted le was not collected by NVt. personnel, then ((1%=04%, 5% with n the accuracy 1 - %, 10%°5 - 15%, 0%,= 3%, 5 the % -60%). the items tested, If camp royal of NVL Laboratories, Inc. I methodology and acuity of the sample collector. This report shalt not be reproduced except in full, out written app shall Pace t t or 2 not be used to claim product endorsement by NVtAP or any other agency of the US Government. (AV 1 2 NVL Laboratories Inc. For the scope of accreditation under NVLAP Lab Code 102063 -0 4708 Aurora Ave. N., Seattle, WA 98103 Tel: 206.547.0100, Fax: 206.634.1936 Bulk Asbestos Fibers Anal sis www.nvllabs.cam By Polarized Light Microscopy Client: PBS Environmental (Seattle) Address: 2517 Eastlake Ave E, Suite 100 Seattle, WA 98102 Attention: Mr. Harry Goren Project Location: Northfield Car Wash Description: Gray fibrous material Non - Fibrous Materials: Fine particles, Glass beads Lab ID: 28082180 Client Sample #: 6 Location: Northfield Car Wash Layer 1 of 3 Description: Tan fibrous material with foil Non - Fibrous Materials: Fine particles, Adhesive /Binder, Metal foil Layer 2 of 3 Description: White woven fibrous material wit Non- Fibrous Materials: Fine particles, Mastic/Binder Layer 3 of 3 Description: Yellow fibrous material Non- Fibrous Materials: Fine particles Lab ID: 28082181 Client Sample #: 7 Location: Northfield Car Wash Layer 1 of 1 Description: Off -white soft material Non - Fibrous Materials: Calcareous particles, Binder /Filler Lab ID: 28082182 Client Sample #: 8 Location: Northfield Car Wash Layer 1 of 1 Description: Off - white chalky material with paper Other Fibrous Materials:% Non-Fibrous Materials: Gypsum/Binder Cellulose 27% Glass fibers 5% Layer 2 of 2 Other Fibrous Materials:% Glass fibers 80% Other Fibrous Materials:% Cellulose 55% h mastic Other Fibrous Materials:% Glass fibers 96% Other Fibrous Materials :% Glass fibers .98% Other Fibrous Materials :% None Detected ND Batch #: 2812872.00 Client Project* 40407.012 Date Received: 10/08/2008 Samples Received: 8 Samples Analyzed: 8 Method: EPAI600R- 93/116 Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND Asbestos Type: % None Detected ND � APO t Sampled by: Client Date: 10/09/2008 Analyzed by: Nadezhda Prysyazhnyuk Reviewed by: Nick Ly Date: 10/09/2008 Nick Ly, P Note: If samples are not homogeneous, then subsamples of the components were r A bestos 1°6=43 %,.5 i bu9%a10%=5-15%, are 0 %d usin ° E EPA 5035=40 - 93/116 Method with the following measurement uncertainties for the reported ersonnel, then the accuracy of the results Is !'united y -60 %). This report relates only to the items tested. If sample was not collected by NVL p methodology. and acuity of the sample collector. This report shall er prod ced except cemmenll, without written approval of NVL Laboratories, Inc. It shall not be used to claim product endorsement by NVLAP or any agency Page 2 of 2 Project: N f;eN Car 1.4).0.5A Analysis requested: Pz.Th Relinq'd by/Signature: Received by /Signature: E f ' 4 . ; results to: ❑ Brian Stanford ❑ Ernest Edwards ❑ Mark Tilley ❑ Gregg Middaugh TURN AROUND TIME: ❑ 1 Hour ❑ 2 Hours ❑ 4 Hours (�/ Janet Murphy Qj Harry Goren ❑ Mike Smith ❑ Prudy Stoudt -McRae ❑ 24 Hours D 48 Hours PBS BATCH ID 2812872.00 - 7 k./ $1 or o f r rooms, r'aonol ve, Lab # Sample# 2 3 L/ Material ,.Jetol4 ;1t Io (1ori4r Door Sea S)of'acyP P.00 00or Coo tiLia A -row.) C n v 7;04 tls`• f- A b4i.c (Ua c! Roe ( PA: I k Aajr,c I 1'oe 14“, e// µ per lA �Ove. Ca, 11,a6 /) a D . r 1C� 14'$3 ape'•( 7r () i',�n�G >l�f, (Ai; r P n h5t 1 L; o, . On t,i, Pe .s / e, L-C bays S Location Lab Ciecif.;caI Pole- Oh' cks Q% out S:1Mut.r A bastos'LabChaio-of•Castody.doe PBS Ii.WIRONMENFAL .1717 Eastlake Avg B• Soho 100.5BATILF, WASHINGTON 96102. (206)433-9629. FAX: (2061.7624780 Project #: L /0'1 a7. 0 / , Date: /C/6/0 Date/Time: / /C 45 Date/ Time: 8709 I(: S i ❑ Willem Mager ❑ Tim Ogden ❑ Ferman Fletcher ❑ Other ❑ 5 Days 13 Other 3 Da y5 qYk 0 ACCRIEDITED LABORATORY AIHA - IH 8101861 NVL LABORATORIES.INC 4708 AURORA AVE N SEATTLE. WA 98103.6516 TEL 206.547.0100 FAX 206.634.1936 nvllabsenvllabs.Com October 13, 2008 Harry Goren PBS Environmental (Seattle) 2517 Eastlake Ave E, Suite 100 Seattle, WA 98102 RE: Metals Analysis; NVL Batch # 2812871.00 Dear Mr. Goren, Enclosed please find the test results for samples submitted to our laboratory for analysis. Examination of these samples was conducted using analytical instruments in accordance to U.S. EPA, NIOSH, OSHA and other ASTM methods. For matrix materials submitted as paint, dust wipe, soil or TCLP samples, analysis for the presence of total metals is conducted using published U.S. EPA Methods. Paint and soil results are usually expressed in mg /Kg which is equivalent to parts per million (ppm). Lead (Pb) in paint is usually expressed in 'mg /Kg (ppm) , Percent ( %) or mg /cm by area. Dust wipe sample results are usually expressed in ug/wipe and ug /ft TCLP samples are reported in mg /L (ppm). For air filter samples, analyses are conducted using NIOSH and OSHA Methods. Results are expressed in ug /filter and ug /m Other matrix materials are analyzed accordingly using published methods or specified by client. The reported test results pertain only to items tested. Lead test results are not blank corrected. For recent regulation updates pertaining to current regulatory .levels or permissible exposure levels, please call your local regulatory agencies for more details. This report is considered highly confidential and will not be released without your approval. Samples are archived for two weeks following analysis. Samples that are not retrieved by the client are discarded after two weeks. Thank you for using our laboratory services. if you need further assistance please feel free to call us at 206 -547 -0100 or 1- 888 - NVLLABS. Sincerely, Nick Ly, Technical Director Enclosure: gala M 3 T tt . 13 C S CIA LE3 • VI P1174 • :.-0 %WIC' L A S H A Z A R O O U S MATERIALS scavrcts www.nrllabs.com 1.888.NVL.LABS (685.52271 i .�h NVL Laboratories Inc. 4708 Aurora Ave. N., Seattle, WA 98103 Tel: 206.547.0100, Fax: 206.834.1936 www.nvllabs.com Lab ID 28082165 28082166 28082167 28082168 28082169 28082170 28082171 28082172 28082173 28082174 Client: PBS Environmental (Seattle) Address: 2517 Eastlake Ave E, Suite 100 Seattle, WA 98102 Attention: Mr. Harry Goren Project Location: Northfield Car Wash Client Sample # Pb1 Pb2 Pb3 Pb4 Pb5 Pb6 Pb7 PbB Pb9 Pb10 Anal AIHA - IH # 101861 sis Report WA-00E# C1765 Total Lead (Pb) Sampled by: Client Analyzed by: Michael Dougherty R eviewed by: Nick.Ly Date Analyzed: 10/13/2008 Date Issued: 10/13/2008 Sample RL in Results Results in Weight mglKg in mg /Kg percent 0.2555 33.0 200.0 0.0200 0.0996 84.0 < 84.0 < 0.0084 0.0907 93.0 4000.0 0.4000 0.2011 42.0 1 0.0160 0.2317 36.0 < 36.0 < 0.0036 0.2531 33.0. 1200.0 0.1200 0.1580 53.0 2300.0 0.2300 0.1852 45.0 .2200.0 0.2200 0.2275 37.0 870.0 '0.0870 0.2525 33.0 1300.0 0.1300 mg/ Kg = Milligrams per kilogram Percent = Milligrams per kilogram / 10000 Note : Method QC results are acceptable unless stated otherwise. Unless otherwise indicated the condition of all sam les wa s acceptable at time of receipt. 0 A te... ACCRBD1TBD• LABORATORY Batch #: 2812871.00 Matrix: Paint Chips Method: EPA 7000B Client Project #: 40407.012 Date Received: 10/08/2008 Samples Received: 10 Samples Analyzed: 10 RL = Reporting Limit 4 = Below the reporting Limit Page 1of1 1K;� 1. 4'v. .-� �1�. 'IE:1 L�= '" yi ! r ' « S ' , +"'��. S x� 1 F. 1 'rL 5 �r ' . ti • V .1, Vii. 1.0 :til' ; .1:,s fMlf is• 'fi • 40tW �Cf�l . Lab # Sample '# n Material". / r S Location .La b Pb I PO - L . ; to /luau Ce i; .J n go .1 Car ti!GSh Iay Ceil stera • Pb2 Pa ; A1 , /`voD /Ye //cio Pb3 far.1/ /v' efat Cx71fr ;o!' Door P bH Pa,( /'/;ie C l"v Cy fir, or a// rb5 Pa,n1 /frf'' 1/ f'a / )4,.fl Ph F P � ? r'Ge n � ��t G.�h; t hum-) t l �r �X"� r; o��T7 *rY1 �Aa gacr r .. /Wcv 6;4 e. r; or ilr;vv. 3rd Au ri, 8 fainil !`Ub cat;r 1rir \ Lt IA 6a P16 I f; .Jj/tz4 oil, ic e I . i -W., or I fin" '1 ttiQ i Ch la 4 -ef it x - Cr l , F 1 rift, Z4-1ca I Project: A/ i,4 -f ; /d Car (4/a3, Analysis requested: L ed e / /L5 Relinq'd by/Signature: Received by /Signature: On I : C A A ; f results to: ❑ Brian Stanford ❑ Ernest Edwards ❑ Mark Hiley ❑ Gregg Middaugh TURN AROUND TIME: 0 0 0 1 Hour 2 Hours 4 Hours ❑ 24 Hours ❑ 48 Hours PBS Janet Murphy Harry Goren ❑ Mike Smith ❑ Pnidy Stoudt -McRae BATCH ID 28 12871.00 Project #: I f° yo /0 /C/6 /0h/0 5(- 10;01 Date: Date/Time: Date/Time: S:1MastenVtsbestos ab C1taLw[•Custody.doe PUS ENvIROT0M8M'Al.25 7 Euilikc Ave S. Sege IGO. SEAMS. WASHINGTON 9802. (206)71 3-9639. FAX: (206)7621780 IbJr3 /or 8 ❑ Willem Mager ❑ Tim Ogden ❑ Ferman Fletcher ❑ .Other - ❑ 5 Days ta- Other 3 D ay 5 Instructor 1-PA Provider Cert. Number: 1085 Certificate of Completion Irbig tO to certifp dot Janet Murphy bas catidattoritp contpieteb 4 fours of refreober training ao an Asbestos Building Inspector to tom* With the training requireinentg of TbeZt Title 3131 / 40 Qtjfl& 763 (13Q30 Expiration Date: Jun 18. 2009 19(8) W. Nickerson. Suite 315 • Seattle. Washington • 98I 19 • (206) 285.3373 • fax (206) 285.3927 Candidate Results One Parcel Found: Parcel Number Address 3348400784 5022 S 118TH ST I A Search Menu Page 1 of 1 Inn 7 MIKE CUSICK 6300 SOUTHCENTER BL, STE 100 TUKWILA WA 98188 RE: Permit No. D08 - 477 14224 TUKWILA INTERNATIONAL BL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/18/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/18/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, N'l Bill Rambo Permit Technician File: Permit File No. D08 -477 City of 7 'u la Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 .Snuthrenter Rnrrlevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 USG u1G gJvaLC1 LPL LL1‘I aIA..ICL•c..a�/u QUANTITY IN CUBIC YARDS au.. .v .... - - -_ —. RATE Up to 50 CY Free 51— 100 $23.50 101— 1,000 $37.00 1,001— 10,000 $49.25 10,001— 100,000 $49.25 for 1 10,000, PLUS $24.50 for each additional 10,000 or fraction thereof. 100,001— 200,000 $269.75 for 1 100,000, PLUS $13.25 for each additional 10,000 or fraction thereof. 200,001 or more $402.25 for 1 200,000, PLUS $7.25 for each additional 10,000 or fraction thereof. BULLETIN A2 TYPE C PERMIT FEE ESTIMATE PLAN REVIEW AND APPROVAL FEES DUE WITH APPLICATION PW may adjust estimated fees ,� X08 PROJECT NAME y IV,iDV QX l t4i 2 - PERMIT # If you do not provide contractor bids or an engineer's estimate with your permit application, Public Works will review the cost estimates for reasonableness and may adjust estimates. 1. APPLICATION BASE FEE 2. Enter total construction cost for each improvement category: Mobilization Erosion prevention Water /Sewer /Surface Water - i c)i Road/Parking/Access A. Total Improvements 3. Calculate improvement -based fees: B. 2.5% of first $100,000 of A. C. 2.0% of amount over $100,000, but less than $200,000 of A. D. 1.5% of amount over $200,000 of A. 4. TOTAL PLAN REVIEW FEE (B +C +D) 5. Enter total excavation volume cubic yards Enter total fill volume cubic yards Use the following table to estimate the grading plan review and permit fee. GRADING Plan Review and Permit Fees TOTAL PLAN REVIEW AND APPROVAL FEE DUE WITH PERMIT APPLICATION (1 +4 +5) $ 5 The Plan Review and Approval fees cover TWO reviews: 1) the first review associated with the submission of the application/plan and 2) a follow -up review associated with a correction letter. Each additional review, which is attributable to the Applicant's action or inaction shall be charged 25% of the Total Plan Review Fee. Approved 09.25.02 Last Revised Jan. 2008 1 $250 (1) p „ i H1 e - C u s ,'c k.) $ S ° i (4) $ (5) ACTIVITY NUMBER: D08 -477 PROJECT NAME: NORTHFIELD CARWASH DEMO DATE: 10 - 23 - 08 SITE ADDRESS: 14224 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bull Ing Division Public Worlds -, ' V� -' Q(UIL (�I/U D Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP Ell r 10— Fire Prevention Structural TERMINATION OF COMPLETENESS: (Tues., Thurs.) Approved with Conditions Incomplete ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: LETTER OF COMPLETENESS MAILED: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required ❑ 6144 14_ 1,1Y1A Planning Division ❑ Permit Coordinator ❑ DUE DATE: 10-28-08 Not Applicable No further Review Required ❑ DATE: DUE DATE: 11- 25-08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 AMERICAN STATES INS CO 6578555 06/02/2008 Until Cancelled 06/05/2006 06/05/2006 $12,000.00 06/03 /2008 1 AMERICAN STATES INS CO 6428649 06/16/2006 Until Cancelled 08/05/2008 $6,000.00 07/05/2006 Name Role Effective Date Expiration Date TRAVERSO, PAUL PARTNER /MEMBER 07/05/2006 Amount TRAVERSO, MARK PARTNER /MEMBER 07/05/2006 PACIFIC NORTHWEST EARTHWORKS L PARTNER /MEMBER 06/05/2006 06/05/2006 Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&l to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company FALL CITY WA 98024 KING Limited Liability Company Business Owner Information Bond Information Insurance Information • PACIFIC NW EARTHWORKS LLC 4252220874 P.O. BOX 351 UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 1 602616523 ACTIVE PACIFNE943LE CONSTRUCTION CONTRACTOR 7/5/2006 7/5/2010 GENERAL UNUSED https: / /fortress.wa. gov /lni/bbip/Detail.aspx ?License= PACIFNE943LE Page 1 of 2 02/19/2009 KING COUNTY TUKWILA VILLAGE NORTHFIELD CAR WASH DEMO JOAN HERNANDEZ I" It OF - 1 1 1J KWI L KATHY HOUGARDY BOB GIBERSON, P.E. CITY ENGINEER PROJECT Nom. 00 BG -22 CITY FFICIALS MAYOR HAGGERTON JOE H. DUFFIE DE!SEAN QUINN COUNCIL JIM MORROW, P.E. DIRECTOR OF PUBLIC WORKS REVISIONS No changes shall be made to t h e l of of work without prior app Tukwila Building Division. NOTE: may i additional al plan e and review fees. PAMELA CINDER WASHINGTON VERNA GRIFFIN 10 29_ FILE Permit No. Plan review approval Is subject to errors eyed omissions. Approval of construction does not authorize the violation of = ► opted code o • rd!narrce• Receipt of approved oaa is acknowledged: City of Tukwila BUILDING DIVISION ' KtVltvvcu ruts CODE COMPLIANCE APPROVED A OCT 31 n 2008 City Of Tukwila BUILDING DMSION These plans have been reviewed by the Public Works Department for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards or ordinances. The responsibility for the adequacy of the design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field inspection b the Public Works utilities inspector -_ Date: _= By CITY CLERK CITY ADMINISTRATOR RECEIVED CITY OF TUKWILA OCT 2 , 3 2008 PERMIT CENTER DE NIS ROBERTSON DOSH41- CHRISTY O'FLAERTY RHONDA BERRY GENERAL NOTES Locations shown for existing utilities are approximate. At least 48 hours before starting project site work, notify the Utilities Inspector at 206- 433 -0179. 3. Request a Public Works utility inspection at least 24 hours in advance by calling 206- 433 - 0179. 4. The Contractor assumes sole responsibility for worker safety, and damage to structures and improvements resulting from construction operations. The Contractor shall have the perm it(s) and conditions, the approved plans, and a current copy of City of Tukwila Development Guidelines and Design and . Construction Standards available at the job site All work shall conform to these approved drawings. Any changes from the approved plans require pre- approval from the owner, the engineer, and the City of Tukwila. 7. All methods and materials shall meet City of Tukwila Development Guidelines and Design and Construction Standards, unless otherwise approved by the Public Works Director. 8. Contractor shall maintain a current set of record drawings on- site. 9: .C— i -approval. J$ 10. Provide traffic control and street maintenance plan for Public Works approval before implementation. 11. All surveying for public facilities shall be done under the direction of a Washington licensed land surveyor. Vertical datum shall be NAVD 1988. Horizontal datum shall be Washington State (grid) Coordinates, North Zone, using NAD 83/91 survey control and tied to any two City of Tukwila Horizontal Control Monuments. For projects within a flood control zone, the Permittee shall provide conversion calculations to NGVD 1929. 12. Replace or relocate all signs damaged or removed due to construction. 13. Retain, replace or restore existing vegetation in rights —of —way, easements, and Access Tracts. SHEET I\ EX COVER SHEET DEMO PLAN UTILITY PROVIDERS: SANITARY SEWER VALLEY VIEW SEWER DISTRICT 3460 S 148TH ST, SUITE 100 TUKWLIA WA 98168 PH # ( 206) 242 -3236 WATER WATER DISTRICT /125 3460 S 148TH ST, SUITE 110 TUKWLIA, WA 98168 PH # (206) 242 -9547 NATURAL GAS PUGET SOUND ENERGY P.O. BOX 97034 BELLEVUE, WA 98009 -9734 PH # (425) 462 -3381 CONTACT: KATHY JOHNSON STORM DRAINAGE CITY OF TUKWILA 6300 SOUTHCENTER BLVD DEPARTMENT OF PUBLIC WORKS TUKWILA, WA 98188 PH # (206) 433 -0179 FAX # (206) 433 -3665 POWER SEATTLE CITY LIGHT 700 FIFTH AVE SUITE 3300 P.O. BOX 34023 SEATTLE, WA 98124 PH # (206) 386 -1671 CONTACT: MARILYN BOLAND TELEPHONE INTEGRATELECOM INC. 1303 120TH AVE NE BELLEVUE, WA 98009 PH # (206) 812 -3300 CONTACT: BOB ROBERTSON SURYEYOR: LARRY MCANDREWS 12507 BEL -RED ROAD SUITE 101 BELLEVUE, WA 98005 PHONE 425 637 -3693 aar W UNDERGROUND WATER LOCATED BY PAINT SS UNDERGROUND SEWER LOCATED BY PAINT SD UNDERGROUND STORM LOCATED BY PAINT G(L) — UNDERGROUND GAS LOCATED BY PAINT TL OVERHEAD TELEPHONE — P(L) — UNDERGROUND POWER LOCATED BY PAINT PO OVERHEAD POWER FENCE CULVERT ROCKS VEGETATION FOUND MONUMENT IN CASE TRAFFIC BOLLARD SEWER MAN HOLE LIGHT POLE WATER VAULT POWER VAULT CABLE TV VAULT GAS METER FIRE HYDRANT 3 a FIRE DEPT. CONNECT TRAFFIC SIGN WATER VALVE POST INDICATOR GAS VALVE CATCH BASIN WATER METER YARD LIGHT TELEPHONE PEDESTAL TELEPHONE MANHOLE -0- POWER POLE E— GUY Q CATCH BASIN 2 0 0 YD 0 Q CPP RCP LEGEND CONCRETE CURB GUARD RAIL RIGHT OF WAY CENTER LINE FOG LINE ASPHALT GRAVEL CONCRETE RETAINING WALL FLOW LINE HANDICAP HAND HOLE YARD DRAIN BLOW -OFF VALVE PEDESTRIAN SIGNAL POLE OVERHEAD SIGNAL LIGHT DECIDUOUS CONIFER SHRUB HAND HOLE CORRIGATED PLASTIC PIPE REINFORCED CONCRETE PIPE • KtVlrwLi) rum CODE COMPLIANCE 1 APPROVED OCT 3 1Ma City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 2 3 2008 PERMIT CENTER CITY OF TUKWILA PUBLIC WORKS DEPT. ENG IN EERING- STREET'S- WATER - SEWER- PARKS - BUILDING- designed drawn checked roj eng pro,j dir Ield bk n by ■ ■ ■ date 10/08 10/08 NORTHFIELD CAR WASH DEMO COVER SHEET date revisions scale date 10/6/2008 - ENGINEERING - STREETS- WATER - SEWER - PARKS- BUILDING- designed drawn checked proj eng proj dr field bk no cPIRE: v 1424 TU \ \ \ CONC WALL RTHFILE7 CAR WASH <WILA I \TER\ATI \AL BLVD, 4 t 7 - 110 . ltvvr� ru E COMPLIA !P ROVED OC T 3 1 2003 City Of Tu 1) ING DIVISIO SCALE IN FEET O to p t , 0 15, T. 23 l ) \TY WAS R. 4 F ,, I \:3T Ri<OcifIDE SEDIMENT T`6A IN C3 W v CE CONSTRUCTION KEY NOTES 1. EXISTING POWER POLE TO REMAIN. 2. DEMO VAC/ TRASH STATION. REMOVE CONCRETE TO BARE GROUND. BACK FILL AREA WITH 5/8" CRUSHED TOP COURSE. 3. COORDINATE WITH PSE FOR REMOVAL OF GAS METER. PSE TO CA GAS MAIN LINE AT ROW LINE. 4. NOT USED. 5. DEMO SIGN. 6. COORDINATE WITH WD #125 FOR REMOVAL OF THE WATER METE EXISTING METER SET TO REMAIN. 7. COORDINATE WITH VALLEYVIEW SEWER DIST. FOR THE LOCATION OF THE STUB SERVING THE CARWASHING. DIG DOWN A MAX OF 15' AND CAP THE SIDE SEWER. BACK FILL TRENCH WITH NATIVE MATERIAL. THE LOCATION OF THE STUB IS NOT IN TIB AND. TRAFFIC CONTROL IS NOT REQUIRED. 8. DEMO CARWASH AND CONCRETE SLAB. BACKFILL AREA WITH 5/ CRUSHED TOP COURSE FLUSH WITH EXISTING PAVEMENT. 9. REMOVE OIL SEPARATOR TANK. BACKFILL AREA WITH 5/8 CRUSHE TOP COURSE FLUSH WITH EXISTING PAVEMENT. RIV GIN O TUKWL OCT 23 2 PERMIT CENTER R