Permit D08-478 - OAKWOOD HOUSING - STORAGE RACKS
OAKWOOD HOUSING 3225 S 116 ST EXPIRED 10 -20 -09 D08 -478 Parcel No.: 0923049066 Address: 3225 S 116 ST TUKW Suite No: Tenant: Name: OAKWOOD HOUSING Address: 3225 S 116 ST , TUKWILA WA Owner: Name: TTA/E PROPERTY TAX DEPT 207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Phone: doc: IBC -10/06 CRAM' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: BRIAN FERRICK Address: 7373 SE MILWAUKIE EXP , PORTLAND OR 97222 Phone: 503 - 519 -3043 Contractor: Name: B & B INSTALLATIONS INC Address: 14401 S GLEN OAK RD , OREGON CITY OR 97045 Phone: 503 722 -8155 Contractor License No: BBINSI *135B3 DEVELOPMENT PERMIT Permit Number: D08 -478 Issue Date: 03/06/2009 Permit Expires On: 09/02/2009 Value of Construction: $0.00 Fees Collected: $239.63 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: Expiration Date: 03/18/2009 DESCRIPTION OF WORK: 768 SF OF STORAGE RACKS CLASS I - IV. MOSTLY I AND II STORAGE HEIGHT, LESS THAN 12' HIGH TO OF COMMODITY. * *continued on next page ** D08 -478 Printed: 03 -06 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Water Meter: Permit Center Authorized Signature: Signature: Print Name: doc: IBC -10/06 City dinukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: N I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting f this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction the perforn ice of wgrk. A l authorized to sign and obtain this developmen4permit. b co, CA -- woAa Permit Number: D08 -478 Issue Date: 03/06/2009 Permit Expires On: 09/02/2009 Date: 3 lO q Date: This permit shall become n and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -478 Printed: 03 -06 -2009 Parcel No.: 0923049066 Address: Suite No: Tenant: 3225 S 116 ST TUKW OAKWOOD HOUSING 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 8: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -1 0/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -478 ISSUED 10/24/2008 03/06/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 11: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 min) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 12: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) D08 -478 Printed: 03 -06 -2009 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 13: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 14: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 15: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13- 12.3.1.14.1) 16: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 17: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 18: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 19: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: Sprinlder coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2007 edition). 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 23: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D08 -478 Printed: 03 -06 -2009 Signature: Print Name: 0 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D08 -478 Date: 340 0 ordinances governing or local laws regulating Printed: 03 -06 -2009 1 SITE LOCATION E -Mail Address: Company Name: Mailing Address: • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Q: Applications \ Form - Application On knell -2006 - Permit Applimtion.doc Revised: 9 -2006 bh City ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record • Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print ** �� 1 A King Co Assessor's Tax No.: 01„.720 ct G 2 � Site Address: 7a ✓bath / / L , l'i -if' . Suite Number: 1/ 7 Floor: Tenant Name: 0 /,k woad , -- �1 New Tenant: ❑ Yes ❑..No Property Owners Name: J Mailing Address: State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: r 1 Ct ,') rr / G Day Telephone: ..(u 3 3 9 .7a 0/ 7 Mailing Address: 73 7 3 f 4' x 1 , /dr7 /U h(J O / _ / city I state zip g )3 Pe , r (b if Aka , G On--, Fax Number: fU 3 h 3- ?$3 t7 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plum, big and Gas Piping (pg 5)) (j 13 1 /6t. / /G,}: pan pit/ j 6 der 06 k ( / dl efor, O/ 97o City tate zip Contact Person: $ 1.-- 7 UGt, f Day Telephone: /7) 3 7 f3/,1 n � D E -Mail Address: C G - / S J ($ 1.75 Fax Number: 3 3 7 r (� / 3 "� Contractor Registration Number: Expiration Date: 3 / 1e) la q ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: C u rr/ n, — (,h / / Mailing Address: 730 E M&, s 7 51/,',/e / U �-3i �� h v g T -� /o$ - / / city state zip Contact Person: )3 (� h R C,h / Day Telephone: '/ U 02 t b .7 9 E -Mail Address: C I�(/ y /ere A I E T /h /1 /eC Fax Number: `i /� b a ..r 9 n C7'O Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E-Mail Address: Fax Number: Page 1 of 6 4 ti BUILDING PERMIT INFORII�TION - 206- 431 -3670 • Valuation of Project (contractor's bid price): $ y-5—°0 r, 00 Scope of Work case provide detailed information): , 7 V I /6.r tee Existing Building Valuation: $ > S I e S$ *Iv o ,;?z C ti m iw9t/4 Will there be new rack storage? g Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 51- ray e _ le ,, / a h /1 h I Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) i (�1 C 116 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes tn No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantifies and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Upplicatiom\Fomu- Application. On line'3-2006 - Permit Application:doe Revised: 9-2006 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1* Floor »7t.IA'e tee },� 07 /'tt1if l n Floor Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck 4 ti BUILDING PERMIT INFORII�TION - 206- 431 -3670 • Valuation of Project (contractor's bid price): $ y-5—°0 r, 00 Scope of Work case provide detailed information): , 7 V I /6.r tee Existing Building Valuation: $ > S I e S$ *Iv o ,;?z C ti m iw9t/4 Will there be new rack storage? g Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DMSION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 51- ray e _ le ,, / a h /1 h I Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) i (�1 C 116 Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes tn No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantifies and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:Upplicatiom\Fomu- Application. On line'3-2006 - Permit Application:doe Revised: 9-2006 bh Page 2 of 6 L PIIIMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all eases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.32 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.43 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: 7 / JP-‘t Mailing Address.2 7� _ / ,7 Gt ✓�2 i �O D ate Application Accepted: iolv-t1 Q: Appli tFomu- Application on Liae\1 -2006 - Permit Appti®6oadoc Revised: 9-Z006 bh Day Te1ep ir City State Zip • Date Application Expires: ottitoi Date: 4 v DL5 one: SPY LC/ 1 312 v. 4 1 . 71 22— Staff Initials: Page 6 of 6 Payee: R. BRIAN FERRICK ACCOUNT ITEM LIST: Description don: RAr.Aint -OR BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4077 239.63 000/322.100 000/345.830 000/386.904 RECEIPT Parcel No.: 0923049066 Permit Number: D08 -478 Address: 3225 S 116 ST TUKW Status: PENDING Suite No: Applied Date: 10/24/2008 Applicant: OAK WOOD HOUSING Issue Date: Receipt No.: R08 -03617 Payment Amount: $239.63 Initials: JEM Payment Date: 10/24/2008 04:32 PM User ID: 1165 Balance: $0.00 Account Code Current Pmts 142.50 92.63 4.50 Total: $239.63 • Printad• 1n- 74 -7nfR Project: : ,' -) Ty nspection: Address: -A S -•- ,S //.4, Suite #: Contact Person: Special Instructions: • Phone N•.: ao6- E.3C- V3Jj Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre - Fire: Permits: p Occupancy Type: INSPECTION NUMBER ri Approved per applicable codes: INSPE TION RECORD Retain a copy With permit . CITY OF TUKVVILA FIRE DEPARTMENT b.-17 L1178 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Word /Inspection Record Form.Doc 1/13/06 rrections required prior to approval. COMMENTS: Pr 'rkeArt ' 4 pm-60r 1 i S s /i ©>t CoAld 4410d /I.z ►ye1)A; /) i a A �"it I+Ntq�L ti '.�_a b c�" 'fib q lC e l y 5P Date: 1A3 /d 7 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 OTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing Report Number: 100384 Description: Expansion Anchors Project: Oakwood Corporate Housing Address: 32255 S 116 St, Suite 117, Seattle Client: Norlift of Oregon, Inc. CONSTRUCTION INSPECTION REPORT D08 -478 TiTCEIVED IAN 22 2051 c`O,�M, hIJIW r `"':t�s'; ' Permit Number: Job Number: Client Address: PO Box 68348, Portland, OR 97268 Inspector and Date Remarks Wayne Barker On site to inspect the torquing of Hilti KB -TZ wedge anchors installed at the corners of the racks. 10/31/2008 Anchors torqued to 40 foot pounds. Conforms to ICC ESR #1917. Conforms to Engineer's RFI; No Permit/City Approved Plans on Site Copies to: X Client Contractor Architect X Building Dept. Technical Responsibility: X Engineer Jeff Rabe, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of 1 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725 - 4600 or 1 888 - OTTO - 4 - US - Fax (206) 723 - 2221 Form No.: ADMIN -63 -01 (Rev 05/03) FROM : illar ' iii MI IS II imr tars vir •� at I: 7 I Milk Al OF OREGON, INC. Material Handling Specialists City of Tukwila 6300 Southcenter Boulevard Tukwila WA 98188 206 -431 -3670 Al Metzler Thank you Brian Ferrick Cell phone 503-519-3043 FAX NO. : RECEIVED j FEB 9 9 2009 /°12-, Suite 1001TY OF TUKWILA CITY CLERK s _, CJ In regards to Oak Wood Housing at 3225 SW 116 Street suite 117 Permit # D08 -478 The product to be stored is house wares, small house old items to set up an apartment for short term. Dishes, silverware, micro waves, linens, coffee makers pictures. The material will not be stored above 12' high The items will not be encapsulated They will be on racks with open wire decking with a 2" X 4" or larger pattern which is widely used and a very common industry standard Vertical and longitudinal flue spaces will be provided. The racks are 48" deep with an 8" flue space between double rows there are no multiple rows There will also be spacing at each upright The total square footage of racking storage including the aisles is approximately 2000 SQ FT or less and non public accessible The aisles between the racks are 5' , 10' and 12' There will be 1 fire extinguisher for every 3000SQFT of warehouse space or 1 every 75' of travel. The sprinkler system is .39GPM /5600 SQFT FILE COPY Permit No.3) O 6- y11 a Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize }I�r v% %1 firer. "4 - «. - mina +01e4 ,rd' nr nreli»nnnn Danoirl} CORRECTION! boa - 478 �� , Ie NISSAN �__ f/NGHE /NR /CH (Kalmar Feb. 17 2009 11:00AM P2 7373 S.E. M!Iwaukie Expressway Portland, Oregon 97222 P.O. Box 68348 • Portland, Oregon 97268 (503) 659-5438 • FAX (503) 653 -6966 1- 800 -452 -0050 www.nor /Iffor.cam PRINCETON REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 3 2009 City of Tukwila DIVISION RECEIVE FEB 2 0 2009 PERMIT CENTS, CLgRK JLU f BRACE z X J 0 U 4' -0' UPRIGHT z X D J 0 U 14GA THK 10' -0' 1 -5/8' LOAD BEAM 0.11'x 3'x 4' BASEPLATE (1) 1/2'0 ANCHOR 1/8 " 1 -1/2' EA FACE COLUMN & BASE PL 3/4'H x 1' W STEP 14 GA THICK 1 7 PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED CONSPICUOUS LOCATI ❑N STATING ACITY @ 8', 60', 120' /O 00 -24+- C t�C n, t P- 8' -0' LOAD BEAM ELEVATION C 1.5 x 1.25 1.5 14 GA THK n 2' OF 1/8' FILLET WELD EA END TO COLUMN BRACE (2) PIN CONN 0 LOAD BEAM CONNECTOR LOAD BEAM CONNECTOR LOAD BEAM LOAD BEAM 1- 0_ w 1/8' BRACE 5' -0' 4' -4' (2) AISI A502 -2 RIVETS 7/16'0 4'oc HOOK THRU SLOTS IN COLUMN Z0 1 -5/8x 3x 3/16' THK CONNECTOR 1 /8 VERT EDGES z f J 0 U BRACE CONN COLUMN 1/8 rI -1/2' EA SIDE z E -J 0 U 5 COLUMN -BEAM CONN Ali, u l 1n,5 1( l& (Iii ,(,b-‘ up) or ,6g /45 -71r7 (L e91e/.e-- aoor FILE COPY Permit No. b....12E5,2ft... Plan review approval is subject to errors and moons. Approval of construction documents does not authorize 0.11x 3x 4 BASEPLATE (1) 1/2'0 ANCHOR 3.25' FF 5' CONCRETE SLAB ON GRADE COLUMN BASE X- SECTION SAFETY PIN TO RESIST 1000# UPLIFT LOAD REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 3 2009 -' W City of Tukwila DUILDtNG DIVISION V) 1- 0 z I I I I II I I I I W u GO Q o6 0 A \D O O CU CZ LJ 0_ LJ Z N LJ .-i (U RECEIVED CI 1 i OF TUB` OCT 2 4 2005 PERMIT CENTER 4- V (/) A o A o ce �o dj L j i °w�w LJ 0 Ow X Q v) Ui W 0 D W (/) 0 ce W x O A wozZ (/) JQ J Q W 1- 4: ( lf) F- 0 0_ LJ CZ 0 PU 0 OC LJ 11 L 0 z(- CD O I V ) cJ 0 LLJ F (4 Ln (Y) LJ 0 Calculations for : OAKWOOD CORP. HOUSING TU KWI LLA, WA Loading: 1000 #load levels allet levels © 8,60,120 Seismic per IBC 2006. 100% Utilization Sds = 1.000 Sdl = 0.520 I = 1.00 96 " Load Beams Uprights: 48 " wide C 3.000x 1.625x 0.075 Columns C 1.500x 1.250x 0.075 Braces 3.00x 4.00x 0.110 Base Plates with 1- 0.500in x 3.25in Embed Anchor /Column 2.75x 2.750x 0.075 Load beams w/ 2 -Pin Connector by : Ben Riehl Registered Engineer WA# 21008 10/17/2008 E.,.,.S,e 10/2 /D i REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 3 2009 City of Tukwila BUILDING DIVISION Conterminous 48 States 2003 NEHRP Seismic Design Provisions Latitude = 47.4988 Longitude = - 122.2904 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.501 (Ss, Site Class B) 1.0 0.518 (S1, Site Class B) Conterminous 48 States 2003 NEHRP Seismic Design Provisions Latitude = 47.4988 Longitude = - 122.2904 ' Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 =FvxS1 Site Class D- Fa= 1.0 ,Fv = 1.5 Period Sa (sec) (g) 0.2 1.501 (SMs, Site Class D) 1.0 0.777 (SM1, Site Class D) IBC 2006 LOADING SEISMIC: Ss= 150.1 % g S1= 51.8 %g Soil Class D Modified Design spectral response parameters Sms= 150.1 % g Sds= 1 00.1 % g Sm1= 77.7 % g Sdl= 51.8 % g Seismic Use Group 1 Seismic Design Category D or D le = 1 AC► •i .. 7726 ; R= ; 4 R = 6 f 01-1,:,i_j'•0' ..-', :;CS=i; i 0.2502 W Cs= 0.1668 W 03 v �. ng, Working Stress Design V = Cs - W/1.4 ,. ;;, ,; V= : 0.1787 W V= . 0.1191 W • 1 . ,. r'`.' ` t � i. I Depth 3.000 in Flange 1.625 in Lip 0.750 in Thickness 0.0750 in R 0.1000 in Blank = A = Ix = Iy = a a bar b b bar c c bar u gamma R' Section Removing: 0.640 inch slot 0.375 inch hole A- = 0.152 in2 I'x = I'y = Depth Flange Lip Thickness R Blank = A = Ix = Iy = a a bar b b bar c c bar u gamma R' Cold Formed Channel Cold Formed Channel 1.500 in 1.250 in 0.000 in 0.0750 in 0.1000 in 3.73 in 0.280 in2 0.106 in4 0.046 in4 1.1500 1.4250 1.0750 1.2125 0.0000 0.0000 0.2160 0.0000 0.1375 Fy = 55 ksi 7.21 in wt = 1.8 plf 0.541 in2 0.750 in4 Sx = 0.500 in3 Rx = 1.177 in 0.217 in4 Sy = 0.223 in3 Ry = 0.633 in 2.6500 2.9250 1.2750 1.5500 0.5750 0.7125 0.2160 1.0000 0.1375 Web w/t 35.3333 Flg w/t 17.0000 x bar 0.6139 m 0.9488 x0 - 1.5627 J 0.0010 x web 0.6514 x lip 0.9736 h/t 38.0000 0.75 inches each side of center on web 0.87 inches from web in each flange A' = 0.389 in2 x bar = 0.728 in 0.573 in4 S'x= 0.382 in3 R'x= 1.213 in 0.172 in4 S'y= 0.184 in3 R'y= 0.665 in Fy = 55 ksi wt = 1.0 plf Sx = 0.141 in3 Rx = 0.614 in Sy = 0.056 in3 Ry = 0.403 in Web w/t 15.3333 Flg w/t 14.3333 x bar 0.3946 m 0.5298 x0 - 0.9244 J 0.0005 x web 0.4321 x lip 0.8179 h/t 18.0000 COLUMN SECTION BRACE SECTION HEIGHT OF BEAM MAT'L THICKNESS INSIDE RADIUS WIDTH STEEL YIELD L LONG SIDE 2.4000 TOP 1.4000 STEP SIDE 0.4750 STEP BOTT 0.7250 SHORT SID 1.6500 BOTTOM 2.4000 CORNERS 2 3 4 5 6 AREA = CENTER GRAVITY = Ix = Sx = Rx = Cold Formed Section 2.750 INCHES 0.075 INCHES 0.100 INCHES 2.750 INCHES 55.0 KSI STEP 0.750 INCHES HIGH ABOUT THE HORIZONTAL AXIS Y LY LY2 Ii 1.3750 3.3000 4.5375 1.1520 2.7125 3.7975 10.3007 0.0000 2.3375 1.1103 2.5954 0.0089 1.9625 1.4228 2.7923 0.0000 1.0000 1.6500 1.6500 0.3743 0.0375 0.0900 0.0034 0.0000 0.2160 2.6625 0.5751 1.5311 0.0004 0.0875 0.0189 0.2160 2.6625 0.5751 1.5311 0.0004 1.6625 0.3591 0.2160 2.0125 0.4347 0.8747 0.0004 1.8000 0.3888 0.2160 1.9125 0.4131 0.7900 0.0004 2.6625 0.5751 0.2160 0.0875 0.0189 0.0017 0.0004 2.6625 0.5751 0.2160 0.0875 0.0189 0.0017 0.0004 0.0875 0.0189 TOTALS 10.3459 18.8500 13.4063 26.6096 0.776 IN2 1.296 INCHES TO BASE 0.808 IN4 Iy = 0.556 IN3 Sy = 1.021 IN Ry = 1.000 INCHES WIDE LOAD BEAM ABOUT THE VERTIC X LX 0.0375 0.0900 0.8750 1.2250 1.7125 0.8134 2.2125 1.6041 2.7125 4.4756 1.3750 3.3000 1.5376 17.8875 13.4439 1.299 INCHES TO LONG SIDE 0.825 IN4 0.569 IN3 1.031 IN RIVETS BEAM END CONNECTOR COLUMN MATERIAL THICKNESS = 0.075 IN LOAD BEAM DEPTH = 2.75 IN TOP OF BEAM TO TOP OF CONN= 0.000 IN WELD @ BTM OF BEAM = 0.000 IN LOAD = 1000 LBS PER PAIR CONNECTOR VERTICAL LOAD = 250 LBS EACH 2 RIVETS @ 4 " oc 0.4375 " DIA A502 -2 1st @ 1 "BELOW TOP OF CONNECTOR AREA = 0.150 IN2 EACH Fv = 22.0 KSI Vcap = 3.307 KIPS EACH RIVET BEARING Fb = 65.0 KSI BRG CAP= 2.133 KIPS EACH RIVET TOTAL RIVET VERTICAL CAPACITY = 4.266 KIPS 6% CONNECTOR 6 " LONG CONNECTOR ANGLE Fy = 50 KSI 1.625 " x 3 " x 0.1875 " THICK WELDS S = 0.131 IN3 Mcap = 3.924 K -IN W/ 1/3 INCREASE = 5.232 K -IN RIVET MOMENT RESULTANT @ 1.5 IN FROM BTM OF CONN M = PL L = 1.75 IN Pmax = Mcap /L = 2.989 KIPS RIVET LOAD DIST MOMENT P1 2.844 3.500 9.953 RIVET OK P2 0.000 -0.500 0.000 P3 0.000 0.000 0.000 P4 0.000 0.000 0.000 TOTAL 2.844 9.953 CONNECTOR OK 0.125 " x 2.750 " FILLET WELD UP OUTSIDE 0.125 " x 2.000 " FILLET WELD UP INSIDE 0.125 " x 0.750 " FILLET WELD UP STEP SIDE 0 " x 1.000 " FILLET WELD STEP BOTTOM 0 " x 2.750 " FILLET WELD ACROSS BOTTOM 0 " x 1.750 " FILLET WELD ACROSS TOP USE EFFECTIVE 0.075 " THICK WELD L = 5.50 IN A = 0.413 IN2 S = 0.189 IN3 Fv = 26.0 KSI Mcap = 4.92 K -IN W /1/3 INCR= 6.55 K -IN Weight Overturning Anchors: Braces: V = In Upright Plane Seismic Load Distribution per 2006 IBC Ca = 0.400 Use : Tcap = I = 60 # per level frame weight Columns @ 48 " Levels Load WiHi Fi FiHi Column: (inches) ( #) (k -in) ( #) (k -in) C 3.000x 1.625x 0.075 120 1060 127 243 29 60 1060 64 121 7 8 1060 8 16 0 KLx = 13.6 in 0 0 0 0 0 KLy = 50 in 0 0 0 0 0 A= 0.389 in 0 0 0 0 0 Pcap = 10506 lbs - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 3180 199 380 37 Column 22% Stress Max column load = 2352 # Min column load = 304 # T = OTM = Brace height = Brace width = Length = P = 1.33 Allowable Stress Increase 1.00 R = 4.0 V = (2.5 *Ca *I) /(R *LF) *P1 *.67 LF = 1.4 36.6 K -IN X 1.15 = RM = REQUIRED HOLD DOWN = 42.0 K -IN 76.3 K -IN 0.00 KIPS Special Inspection(Y or N)? YES 0 No uplift anchors req'd 1 0.5 " diameter Hilti TZ 3.25 "embedment in 2500 psi concrete 4356 # 0% Stressed 190 # per leg Vcap = 5678 # = COMBINED = 50 " 48 " 69 " 549 # C 1.500x 1.250x 0.075 A = 0.280 in L/r = 172 Pcap = 1920 # 29% OK 2 2 3% Stressed 3% Stressed T per 2006 IBC Ca = 0.400 Weight Overturning Anchors: Braces: V = In Upright Plane Seismic Load Distribution TOP LOAD ONLY Use : Tcap = I = 60 # per level frame weight Max column load = 1108 # Min column load = 72 # T = OTM = Brace height = Brace width = Length = P = C 1.500x 1.250x 0.075 A = 0.280 in L/r = 172 Pcap = 1920 # 1.33 Allowable Stress Increase 1.00 R = 4.0 V = (2.5 *Ca *I) /(R *LF) *P1 LF = 1.4 Columns @ 48 " Levels Load WiHi Fi FiHi Column: (inches) ( #) (k -in) ( #) (k -in) C 3.000x 1.625x 0.075 120 1060 127 204 24 60 60 4 6 0 8 60 0 1 0 KLx = 13.6 in 0 0 0 0 0 KLy = 50 in 0 0 0 0 0 A= 0.389 in 0 0 0 0 0 Pcap = 10506 lbs 1180 131 211 25 Column 111 Stress 24.9 K -IN X 1.15 = RM = REQUIRED HOLD DOWN = Special Inspection(Y or N)? YES 2 5 # 2 1 0.5 " diameter Hilti TZ 3.25 "embedment in 2500 psi concrete 4356 # 01 Stressed 105 # per leg Vcap = 5678 # = COMBINED = 50 " 48 " 69 " 304 # 161 OK 28.6 K -IN 28.3 K -IN 0.01 KIPS 21 Stressed 21 Stressed MSU STRESS -11 VERSION 9/89 - -- DATE: 10/17/:8 - -- TIME OF DAY: 15:31:59 INPUT DATA LISTING TO FOLLOW: Structure Storage Rack in Load Beam Plane 3 Levels Type Plane Frame Number of Joints 14 Number of Supports 8 Number of Members 15 Number of Loadings 1 Joint Coordinates 1 0.0 8.0 S 2 0.0 60.0 S 3 0.0 120.0 S 4 49.5 0.0 S 5 49.5 8.0 6 49.5 60.0 7 49.5 120.0 8 148.5 0.0 S 9 148.5 8.0 10 148.5 60.0 11 148.5 120.0 12 198.0 8.0 S 13 198.0 60.0 S 14 198.0 120.0 .5 Joint Releases 4 Moment Z 8 Moment Z 1 Force X Moment Z 2 Force X Moment Z 3 Force X Moment Z 12 Force X Moment Z 13 Force X Moment Z 14 Force X Moment Z Member Incidences 1 1 5 2 2 6 3 3 7 4 4 5 5 5 6 6 6 7 7 8 9 8 9 10 9 10 11 10 5 9 11 9 12 12 6 10 13 10 13 14 7 11 15 11 14 Member Properties 1 Thru 3 Prismatic Ax 0.776 Ay 0.543 Iz 0.808 3 7 2 6 1 5 4 11 10 9 8 9 PAGE 1 14 13 12 MSU STRESS -11 VERSION 9/89 - -- DATE: 10/17/:8 - -- TIME OF DAY: 15:31:59 4 Thru 9 Prismatic Ax 0.389 Ay 0.194 Iz 0.573 10 Thru 15 Prismatic Ax 0.776 Ay 0.543 Iz 0.808 Constants E 29000. All G 12000. All Tabulate All Loading Dead + Live + Seismic Joint Loads 5 Force Y -0.53 6 Force Y -0.53 7 Force Y -0.53 9 Force Y -0.53 10 Force Y -0.53 11 Force Y -0.53 5 Force X 0.006 6 Force X 0.040 7 Force X 0.081 9 Force X 0.006 10 Force X 0.040 11 Force X 0.081 Solve PROBLEM CORRECTLY SPECIFIED, EXECUTION TO PROCEED Seismic Analysis per 2006 IBC wi di widi2 fi fidi # in # 1060 0.0138 0 12 0.2 6 12 1060 0.1891 38 80 15.1 40 80 1060 0.3627 139 162 58.8 81 161 0 0.0000 0 0 0.0 0 0 0 0.0000 0 0 0.0 0 0 0 0.0000 0 0 0.0 0 0 3180 178 254 74.1 g = 32.2 ft /sec2 T = 0.4949 sec I = 1.00 Cs = 0.1663 or 0.4000 Cv = 0.52 Cs min = .14 *Sds= 0.1400 or 1.5' R = 6 Cs = 0.1663 LF = 1.4 V = (Cs *I) /(LF) *W *.67 V = 0.118750 W *.67 = 253 # PAGE 2 253 100% MSU STRESS -11 VERSION 9/89 - -- DATE: 10/17/:8 - -- TIME OF DAY: 15:31:59 Structure Storage Rack in Load Beam Plane 3 Levels Loading Dead + Live + Seismic MEMBER FORCES MEMBER JOINT AXIAL FORCE SHEAR FORCE MOMENT 1 1 0.000 -0.043 0.00 1 5 0.000 0.043 -2.11 2 2 0.000 -0.050 0.00 2 6 0.000 0.050 -2.48 3 3 0.000 -0.024 0.00 3 7 0.000 0.024 -1.20 4 4 1.584 0.126 0.00 4 5 -1.584 -0.126 1.01 5 5 1.055 0.120 3.23 5 6 -1.055 -0.120 3.00 6 6 0.527 0.078 2.11 6 7 -0.527 -0.078 2.58 7 8 1.584 0.128 0.00 7 9 -1.584 -0.128 1.02 8 9 1.055 0.122 3.27 8 10 -1.055 -0.122 3.08 9 10 0.527 0.084 2.26 9 11 -0.527 -0.084 2.78 10 5 0.000 -0.043 -2.14 10 9 0.000 0.043 -2.13 11 9 0.000 -0.044 -2.16 11 12 0.000 0.044 0.00 12 6 -0.002 -0.053 -2.62 12 10 0.002 0.053 -2.60 13 10 0.000 -0.055 - 13 13 0.000 0.055 0.00 14 7 0.003 -0.027 -1.38 14 11 -0.003 0.027 -1.30 15 11 0.000 -0.030 -1.48 15 14 0.000 0.030 0.00 APPLIED JOINT LOADS, FREE JOINTS PAGE 3 'MSU STRESS -11 VERSION 9/89 - -- DATE: 10/17/:8 - -- TIME OF DAY: 15:31:59 JOINT 5 6 7 9 10 11 2 3 4 8 12 13 14 FORCE X FORCE Y 0.006 -0.530 0.040 -0.530 0.081 -0.530 0.006 -0.530 0.040 -0.530 0.081 -0.530 MOMENT Z 0.00 0.00 0.00 0.00 0.00 0.00 REACTIONS,APPLIED LOADS SUPPORT JOINTS JOINT FORCE X FORCE Y 1 0.000 -0.043 2 0.000 -0.050 3 0.000 -0.024 4 -0.126 1.584 8 -0.128 1.584 12 0.000 0.044 13 0.000 0.055 14 0.000 0.030 FREE JOINT DISPLACEMENTS JOINT X- DISPLACEMENT 5 0.0138 6 0.1891 7 0.3627 9 0.0138 10 0.1891 11 0.3627 JOINT X- DISPLACEMENT 1 0.0138 0.1891 0.3627 0.0000 0.0000 0.0138 0.1891 0.3627 MOMENT Z 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Y- DISPLACEMENT - 0.0011 - 0.0060 - 0.0088 - 0.0011 - 0.0060 - 0.0088 SUPPORT JOINT DISPLACEMENTS Y- DISPLACEMENT 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 ROTATION - 0.0015 - 0.0019 - 0.0010 - 0.0015 - 0.0018 - 0.0009 ROTATION 0.0007 0.0007 0.0002 - 0.0018 - 0.0018 0.0008 0.0011 0.0007 / 2 PAGE 4 Beam - Column Check C 3.000x 1.625x 0.075 A = 0.389 in2 Sx = 0.382 in3 Rx = 1.213 in kx = 1.70 Stress Factor 1.333 Point P M Lx Ly Pcap Mcap Ratio 9 1.6 1.0 8.0 50.0 10.91 16.79 21% 10 1.1 3.3 52.0 50.0 10.91 16.79 30% 11 0.6 2.8 60.0 50.0 9.92 16.79 23% 0 0.0 0.0 60.0 50.0 9.92 16.79 0W 0 0.0 0.0 60.0 50.0 9.92 16.79 0% 0 0.0 0.0 60.0 50.0 9.92 16.79 0% Load Beam Check 2.75x 2.750x 0.075 Fy = 55 ksi A = 0.776 in2 E = 29,500 E3 ksi Sx = 0.556 in3 Ix = 0.808 in4 Length = 96 inches Fy = 55 ksi w/ 25% added to one pallet load M = .282 PL = 6.77 k -in Ry = ky = Pallet Load 1000 lbs Assume 0.5 pallet load on each beam M = PL /8= 6.00 k -in fb = 10.80 ksi Fb = 33 ksi Mcap = 18.34 k -in 24.45 k -in with 1/3 increase Defl = 0.24 in = L/ 397 0.665 in 1.00 33% 37% /3 Shear : Column Load Allowable Soil Assume Footing Soil Pressure Base Plate Design 1.8 kips 1500 psf basic 13.2 in square on side 1488 psf Bending: Assume the concrete slab works as a beam that is fixed against rotation at the end of the base plate and is free to deflect at the extreme edge of the assumed footing, but not free to rotate. Mmax = w1'2/3 Use 3 "square footprint w = Load factor = Footprint Bearing 5 in thick slab f'c = s = 4.17 in3 fb = Fb = 5(phi) (f'c'.5) = Beam fv = Punching fv = 10.3 psi 1.67 2.28625 in2 Bearing: 0.787 ksi 1 = M = 18 psi Fv = 12 psi Fv = 5.1 in 150 # -in 2500 psi 36 psi 163 psi 85 psi 170 psi Use 0.11 " thick 7.75 inches long under column section 0.295 inches wide OK !! OK !! OK !! 1.750 ksi Allowable /4 BRIAN FERRICK 7373 SE MILWAUKIE EXP PORTLAND OR 97222 RE: Permit No. D08 -478 3225 S 116 ST TUKW Dear Permit Holder: Gity of Tukwila Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/20/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 10/20/2009, your permit: will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. D08 -478 Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 03 -02 -2008 BRIAN FERRICK 7373 SE MILWAUKIE EXP PORTLAND OR 97222 RE: Permit Application No. D08 -478 3225 S 116 ST TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 10/24/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Building Code and/or the International Mechanical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and. void. Your permit application expires on 04/22/2009 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 04/22/2009. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and :your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Mar .11 t Technician Permit File No. D08 -478 • Ciiy of Tukwila • Department of Community Development Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Project Name: Oakwood Housing 3225 S 116 St. Permit File No.: D08 -478 Date: November 13, 2008 FIRE DEPARTMENT REVIEW COMMENTS Reviewer: Al Metzler Fire Protection Project Coordinator (206)575 -4407 1. Provide detailed information on the commodities to be stored in the racks to verify chosen class 1 -4 commodity classification. 2. Indicate existing fire sprinkler system density. ACTIVITY NUMBER: D08 -478 DATE: 02 -20 -09 PROJECT NAME: OAKWOOD HOUSING SITE ADDRESS: 3225 S 116 ST Original Plan Submittal X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works C DETERMINATION 0 COMPLETENESS: (Tues., Thurs.) DUE DATE: 02 -24 -09 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROrUTING: Please Route Documents /routing slip.doc 2 -28 -02 EMT C OH C ., 7 • PLAN REVIEW /ROUTING SLIP Structural Incomplete ❑ Not Applicable Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: AWC- a44 .� --n Fire Prevention 1 _! Response to Incomplete Letter # _ Planning Division ❑ Permit Coordinator ❑ No further Review Required DATE: r • DUE DATE: 03 -24 -09 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 -478 DATE: 10 -24 -08 PROJECT NAME: OAKWOOD HOUSING SITE ADDRESS: 3225 S 116 ST DEPARTMENTS: to 4f) Building Drivision 6 rg Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued Comments: Permit Center Use Only • y �`.X' 4.•1: ` INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: ❑ Structural ❑ Permit Coordinator PLAN REVIEW /ROUTING SLIP P PERMIT COORD copy. Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Doruments/routing slip.doc 2- 213-02 1f t 74 ' Fire PY�ve�itlo it4, I/' 1 1 -06 Incomplete ❑ Planning Division Bldg ❑ Fire. Ping ❑ PW ❑ Staff Initials: DUE DATE: 10-28-08 Not Applicable ❑ DUE DATE: 11-25-08 tce FROM : City of Tukwila FAX NO. : • eb. 17 2009 11: 01AM P5 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tulrwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: hun: //www,ci.tukwila.wa•us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc. Date: x1/7/al Plan Cheek/Permit Number: D08 -47$ ❑ Response to incomplete Letter # Response to Correction Letter # 1 O Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: OAKWOOD HOUSING Project Address: 3225 S 116 ST Contact Person: 1( ze^1 f l'/, c, 4- Phone Number: r 3 ,7I J' Summary of Revision: ter !•.ta Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 2 '� giplicationsli'orms- appiicabons on iinolzevision submittal Created: 8-13-2004 Revised: Steven M Mullet, Mayor Steve Lancaster, Director RECEIVED FEB 2 0 2009 PERMIT- CENTEF Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CBIC 619338 01/12/2002 Until Cancelled $6,000.00 03/18/2002 3 CBIC 619338 01/12/1998 01/12/2002 $4,000.00 /15/2008 2 CBIC 619338 01/12/1989 01/12/1998 $4,000.00 1 CBIC 619338 01/12/1987 01/12/1989 Insurance Company Name policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 15 HARTFORD CAS INS CO 52uuniv2510 02/17/200902/17 /2010 $1,000,000.0002 /17/2009 14 CONTINENTAL WESTERN INS CNP2737678 02/17/200802/17 /2009 $1,000,000.0002 /15/2008 Name Role Effective Date Expiration Date BRUCKER, BRETT H 01/01/1980 BAILEY, STUART J 01/01/1980 Untitled Page General /Specialty Contractor • • A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company B & B INSTALLATIONS INC 5037228155 14401 S GLEN OAK RD OREGON CITY OR 97045 OUT OF STATE Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601002894 ACTIVE BBINSI*135B3 CONSTRUCTION CONTRACTOR 1/23/1987 3/18/2009 STEEL /ALUMINUM ERECTORS UNUSED Business Owner Information Bond Information Insurance Information https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= BBINSI* 135B3 Page 1 of 2 03/06/2009 DOOR SCHEDULE DOOR STOR ONT DOOR panel i DOOR b 1 MEM OVARIAO rotas DOOR SCUD CON SOD DOOR 1 JAM CLOW mar REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal end may include additional plan review faes. j REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 3 2009 City of Tukwila BUILDING DIVISION GO GM TAK MOM DV \\Wkst HOUSING CORP SUITE FILE COPY Permit No.bOe � ^I? B Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approveceield Cop and conditions is acknowledged: By 4WC Date: 3- City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW ILA OCT 242008 PERMIT CENTER • DO ( NM DOOR ✓ DRIVE IN DOOR 117 \CD'S \T- l.dwg, 7/8/2008 4:47:22 PM, Acroba APPROVED PALLET RACK DRAWING NO, NB CODE COMPLIAN E APPROVED G MAR 0 3 2009 City of Tukwila BUILDING DIVISION OAKW00D