Loading...
HomeMy WebLinkAboutPermit D08-485 - WESTFIELD SOUTHCENTER MALL - CHAMPS - STORAGE RACKSCHAMPS 1030 SOUTHCENTER MALI. D08 -485 Parcel No.: 6364200010 Address: 1030 SOUTHCENTER MALL TUKW Suite No: Tenant: Name: CHAMPS Address: 1030 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: JENNIFER MIRELES Address: 1327 POST AV #H , TORRANCE CA 90501 Phone: 310 328 -6300 X 105 Contractor: Name: L & L RETAIL CONSTRUCTION LLC Address: 3750 W MAIN ST STE 4A , NORMAN OK 73072 Phone: 405 360 -2775 Contractor License No: LLRETCL954QQ DESCRIPTION OF WORK: RACKING PERMIT FOR RACK STORAGE doc: IBC -10/06 Cityif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us DEVELOPMENT PERMIT Value of Construction: $0.00 Fees Collected: $685.13 Type of Fire Protection: International Building Code Edition: 2006 Type of Construction: IIB Occupancy per IBC: 0019 * *continued on next page ** Permit Number: D08 - 485 Issue Date: 01/15/2009 Permit Expires On: 07/14/2009 Expiration Date: 11/18/2009 D08 -485 Printed: 01 -15 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Signature: Print Name: doc: IBC -10/06 City 6411Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N - '^ Permit Center Authorized Signature: Date: 1 -1S I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Date: Permit Number: D08 - 485 Issue Date: 01/15/2009 Permit Expires On: 07/14/2009 This permit shall become null and void if the work is n commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the 1 pection. D08 -485 Printed: 01 -15 -2009 • City of Tukwila Parcel No.: 6364200010 Address: 1030 SOUTHCENTER MALL TUKW Suite No: Tenant: CHAMPS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 - 485 Status: ISSUED Applied Date: 11/05/2008 Issue Date: 01/15/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Installation of high- strength bolts shall be periodically inspected in accordance with AISC specifications. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 10: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 D08 -485 Printed: 01 -15 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface m accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 19: Extinguishers shall be located m conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 20: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 21: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 22: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 23: Remove the top shelf from all shelving units to maintain maximum storage height to be under 12 feet. 24: Clearance between ignition sources, such as light fixtures, heaters and flame - producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 25: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinldered areas of buildings. (IFC 315.2.1) 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D08 -485 Printed: 01 -15 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us * * continued on next page ** doc: Cond -10/06 D08 -485 Printed: 01 -15 -2009 Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. A..)-- Q kA ' A J v Pt- 1 e___A-L-P rii doc: Cond -10/06 D08 -485 Date: ordinances governing or local laws regulating Printed: 01 -15 -2009 Site Address: CITY OF TUKWI Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tulcwila.wa.us n I ,� nv Ce, i Tenant Name: l AIVS CONTACT PERSON - who do we contact when your permit is ready to be issued GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5) Contact Person: E -Mail Address: Contractor Registration Number: Company Name: _N /k Company Name: LO" ' o Q:WpplicationsWorats- Applications On drol3-2006 - Permit Apphcation.doc Revised: 9-2006 bh 'N.Gvi vie 4 Building Permit No. Mechanical Permit No. City Property Owners Name: Mailing Address: SITE LOCATION pplications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax * *Please Print** Name: An i I Y c Day Telephone: Mailing Address:[ 2- x7 1 1 ?Qs'r A- • Plumbing/Gas Permit No. Public Works Permit No Project No. FOS P (For office use only) King Co Assessor's Tax No.: (SAM 7_ `^ t D Suite Number: ?). Floor: New Tenant: ❑ Yes ❑ ..No State 'TCvvaM . A_ 0O50 City r State Zip s E -Mail Addres tQAtin � 4 O1 P'f 4'MI t ( CW1 Fax Number: 2f 0 31 03 Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State ENGINEER OF RECORD - AU plans must be wet stamped by Engineer of Record Mailing Address: Contact Person: cI Ocf/19t ,� I ( E -Mail Address: Fax Number: Di 32-Le City State Zip Zip 32,2-0 Zip Day Telephone: (,P f t4 • ?-,24,P • z-61)14 Page 1 of 6 5 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. .113 coTTRIMMIIII■ 11e. L BUILDING 0 R 0 Signature: Print Name: 11 // 4 %rite/ Mailing Address :[ea ! P -/ ` u - H Date Application Expires: tg Date Application Accepted: l� (04, Q:\Applications\Fonns- Apphmtcons On Line O-2006 • Perim Applic ation.doc Revised: 9-2006 bh Terri-4/1 e/t- City • Date: oN a Day Telephone: VO 3 (1/ ax/45 Ci 42619/ State Zip Staff Initials: Page 6 of 6 Parcel No.: 6364200010 Permit Number: D08 -485 Address: 1030 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/05/2008 Applicant: CHAMPS Issue Date: Receipt No.: R09 - 00077 Initials: User ID: Payee: WER 1655 ACCOUNT ITEM LIST: Description L & L RETAIL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 31253 582.68 BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 000/322.100 000/345.830 000/386.904 RECEIPT Account Code Current Pmts Payment Amount: $582.68 Payment Date: 01/15/2009 11:56 AM Balance: $0.00 412.50 165.68 4.50 Total: $582.68 1524 01/15 9707 TOTAL 582.68 doc: Receiot -06 Printed: 01 -15 -2009 RECEIPT NO: R08 -03689 SET RECEIPT Initials: JEM Payment Date: 11/05/2008 User ID: 1165 Total Payment: 932.50 Payee: WJCA INC. SET ID: S000001127 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -484 830.05 4EVEQ.0"NO 102.45 TOTAL: 830.05 TRANSACTION LIST: Type Method Description Amount Payment Check 10237 932.50 TOTAL: 932.50 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 TOTAL: 932.50 932.50 Project ("h Afros Type of Inspection: 1---,,,v4 / Address: /d d 11/4/( Date Called: S,ecial Instructions: Date Wanted: 3 - S— o� Cll.( Requester: Phon e No: 07 S6'/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 .1)6S-vg PERMIT NO. (206)431 -3670 COMMENTS: C. 'c :7"/ c-h° I specto : Dat e: $6 0 REINSPECTION FEE t'iEQUIRED /Prior to inspection, fe¢ must be R a i at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: Date: • Approved per applicable codes. El Corrections required prior to approval. Project: C H 4 ,3 . • Sprinklers: Type of Inspection: Ai v4-4_ R „ . A I Address: jp gc 5 .., Suite #: ,.„..,,,, 0 ,44,/ 4 Contact Person: Special Instructions: Permits: Phone No.: Occupancy Type: Needs Shift Inspection: . • Sprinklers: Fire Alarm: Hood & Duct: ` Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila. Wa. 98188 206 - 575 -4407 Approved per applicable codes. COMMENTS: #L'4 . ' F, P ' -14 I r v p l e2P- R Inspector: 5 w $/ Hrs:: • . I Date: 3/s'10 fPX $80.00 REINSPECTION FEE REQUIRED. You-will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit ilvot CITY OF TUKWILA FIRE DEPARTMENT - 44-1 PERMIT NUMBERS Corrections required prior to approval. 1/13/6 • T.F.D. Form F.P. 113 STRUCTURAL CORRECTION D08- 985 FIE V Pc rrnIt PREPARED FOR: PREPARED BY: STORE #14498 SOUTHCENTER MALL 633 SOUTHCENTER - SPACE #324 TUKWILA, WA 98188 �' LEWIS ENGINEERING, INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD., SUITE 5 COLUMBUS, OHIO 43220 (614) 326 -2806 (PH) (614) 326 -2805 (FX) TOTAL NO. SHEETS (NOT INCLUDING THIS SHEET): 9 DATE: 10/30/2008 REV1: 12/3/2008 RECEIVED DEC 10 PERMIT CENTER 41i 7{TIONS REVIEWED FORM CODE COMPLIANCE APPROVED DEC 1 6 2008 LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614- 326 -2806 Fx: 614- 326 -2805 Design Code: 2006 International Building Code Referenced Standards ESR -1385 — Hilti Kwik Bolt 3 concrete anchors ESR -5623 — Self drilling screws ESR -2215 — Mestek Metal Studs Fixed Stock Shelving & Hang Rod Units Design Loads Unit Weights (max case): Unit = 12'- 0 "Hx4'- 0 "Lx1' -0 "W= 150 Ib 8 Shelves w/ 40 lbs. Capacity Each Seismic: (per ASCE 7 -05 section 15.5.3) S = 1.473 S, = .507 Site Class = D (assumed) F =1.0 F„ =1.5 SDS = (2 /3)F = .982 SD1 = (2/3)F„S = .507 Occupancy Category = II Seismic Design Category = D I= 1.0,h„= 12'- 0 ",C,= .02,x =.75, T= T =C,hn = .129,R =4 CS = SDS 245 Csmin =.01 O.K. V = C W =.245W Seismic Overturnin Consider two cases: Case 1 = Wgt of Case 2 = Wgt of 1 D E Csmax D1 983 O.K. 11R/ ) or if S, z .6, then Csmin = ' .063 ( /)_. unit plus all levels loaded to 67% capacity. unit plus top shelf only loaded to 100% capacity. Case 1: CG = .5(12' -0 ") = 6' -0" above floor y = 6.0', x = .5(1') = .5' D = W = (150 Ib) +(8)(40 Ib)(.67) = 364 Ib E = .245 W = (.245)(364 Ib) = 89 Ib E M =(E/1.4)(Y)— (.9D)(x) + R (w) = 0 R Ib (leg uplift) EF R D -R y1 = 583 Ib (If R >= 0, no overturning, if R < 0 = overturning occurs) EF = R = E/1.4= 64 Ib 1 Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington O.K. LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614 -326 -2806 Fx: 614- 326 -2805 Fixed Stock Shelving & Hang Rod Units (cont'd) Seismic Overturning (cont'd) Case 2: Ez Y1 = 6.0', y = 12', x = .5(1') =.5' D = W + W2= (150 Ib) +(1)(40 Ib) = 190 Ib E = .384 W = (.245)(150 Ib) = 37 Ib E2 = .384 W2 = (.245)(40 Ib) = 10 Ib M =(E1/1.4)(y1)+ (E .4)(y - (.9D + R =0 R = -147 Ib (leg uplift), F = R ye = 337 Ib F = R = E +E 33 Ib • 1 D ► '► D Ry' w R Case 1 controls uplift, shear and leg downward load. P = 219 Ib, P down(design) = 583 Ib, Pl = 64 Ib P resisted by 2 leg connections per rack = (1/2)(219 Ib) = 109 Ib per leg Pdown resisted by 2 leg connections per rack = (1/2)(583 Ib) = 292 Ib per leg Pl resisted by 4 leg connections per rack = (1/4)(64 Ib) = 16 Ib per leg Anchorage To Floor Base Plate /Clip - 1-3/4"x1-314x1/8" thick bent plate, 3" wide P = 109 Ib (per leg), B = plate width = 3 ", b = moment arm = .75 ", Fy = 36 ksi t = 6Pb _ 067" O.K. 75F AB) Pdown = 292 Ib (per leg), Aplate = 5.25 ", f = P/A = .056 ksi, N = 1.75 ", bf = 3 ", d = 1.5" n= 1/2(B- .8b =.3 in. t req =2n = .042" F O.K. n' =1/4 db = .53 in. (n = max of n and n') .8bf 2 Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614 -326 -2806 Fx: 614- 326 -2805 Fixed Stock Shelving & Hang Rod Units (cont'd) Anchorage To Floor (cont'd) Plate Connection To Post — (2) 1 /4 "0 TEK Screws P = 109 Ib (per leg) /2 screws = 55 Ib /screw Pdown = 292 Ib (per leg) /2 screws = 146 Ib /screw P lat = 16 Ib (per leg) /2 screws = 8 Ib /screw Vtot = VPmax (up,down) + P I S , = 146 Ib /screw 1 /4' Tek Screw: Vallow (in 14 ga)= 673 Ib OK Wedge Anchors — (2) 1/4 "® Hilti Kwik Bolt 3 Assume normal- weight concrete: fc = 3000 psi Anchor Embedment = 2" Plat = V = 16 Ib, P = T = 109 Ib 2 anchors per plate, therefore: Vanchor = 8 Ib Tanchor = 55 lb Anchor allowable loads: V allow = 449 Ib Tallow = 335 Ib (no spec. insp. req.) (ESR -1385, COLA # RR 25577) Anchor spacing requirements: Spacing required for full allowable = s = 4-1/2" Min spacing required, Smin = 2" (60 % of full Tallow, 90% of full Vallow) Spacing provided = 2 ", therefore by interpolation: Vallow = 404 Ib Tallow = 201 Ib 5 5 Anchor Interaction: V 3 + T 3 = .116 s 1.0 O.K. V allow V allow T allow Check Concrete Slab Puncture Pdown = 292 Ib V = (1.7) 292 Ib = 496 Ib Slab t = 4 ", f'c = 3000 psi (min.) Base Plate Dimensions: B 3 ", B 1.75" Concrete shear area = 2(B + B2 )t = 38 in OV„ = (.85)2 TA, = 3538 Ib O.K. 3 Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington (ER -5623) LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614 -326 -2806 Fx: 614- 326 -2805 Fixed Stock Shelving & Hang Rod Units (cont'd) Check Unit Members Double Rivet Beam Type 2 Per Acro Industries: t = 14 GA = .0747" Ix = 0.03 in. ^4 Sx = 0.02 in. "3 Fy = 36 ksi Load / Level = 40 Ib +20 Ib (Self Weight) = 60 Ib Load / Beam = 30 Ib Max. Beam Span = 4' -0" M = (30 Ib)(48 ")/4 = 0.360 in -k b/t = (0.9375 ")/(0.0747 ") = 12.55 < 76 /NIFy = 12.67, therefore Fb = .6Fy = 21.6 ksi Sreq. = (0.360 in- k)/(21.6 ksi) = 0.017 in ^3 < Sx min. = 0.02 inA3 Double Rivet Beam Type 1 Per Acro Industries: t = 14 GA. Ix = 0.22 in. "4 Sx= 0.13in. "3 Fy = 36 ksi By inspection of Type 2 calcs, Type 1 beam is O.K. T -Shape Unit Upright Per Acro Industries: t = 14 GA. = .0747 A = 0.40 in. "2 Smin = 0.08 in. "3 Rmin = 0.54 in. Fy = 36 ksi L= 12ft Lateral load per leg = 16 Ib Vertical load per leg = 292 Ib (see overturning calculations above) Bending: Distributed lateral load per leg = (16 Ib)/12' = 1.33 plf Mmax = (1/8)(1.33 plf)(12') = 23.9 Ib -ft = .287 k -in f = M/S = 3.59 ksi I = unbraced length = 48" (max), I /r = (48 ")/(0.54 ") = 89, Cb = 1.0 1 1102,000 Cb /F = 53 1 1510,000C b /F = 119 2 F /r Fb F = 17.32 ksi 3 1,530,000 C Or = 0.60F 16.2 ksi (controls) O.K. Axial: f = P/A = (292 Ib) /(.40 in = .729 ksi kl /r = (1.0)(48 ")/(0.54 ") = 89 < C' = 1 12Tr 2 E/QF y = 146 F = 11.8 ksi (AISC equations E2 -1 and A- B5 -11) Combined Axial & Bending: Unity Check = .28 < 1.0 (Equation H1 -3) O.K. 4 - Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington O.K. Imin = 0.117 in. ^4 Q = Qs = 0.75 LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614 -326 -2806 Fx: 614 -326 -2805 Fixed Stock Shelving & Hang Rod Units (cont'd) Check Unit Members (cont'd) 3/4" x 16 GA. Strap X- Bracing w/ 1/4" Bolt Ea. End Strap: Theta = tan -1 (4'/12') = 18.43 degrees Lateral seismic load = 64 Ib Tmax = (64 Ib) /(sin 18.43 deg) = 202 Ib Storefront Framing Assume bolt hole = .375" diameter Agross = (.75 ")(.0598 ") = .045 in Anet = .045 in — (. 375 ")(.0598 ") _ .022 in Tall= .6F = 0.60(36 ksi)(.045 in = 969 Ib Tall= . = 0.50(58 ksi)(.022 in = 650 Ib Bolt: (1/4" dia. A307 bolt, Fv = 10 ksi) Aw = (rr)(0.25 " ^2)/4 = .049 in Vall = (10 ksi)( .049 in = 491 Ib O.K. Design Loads Seismic: (per ASCE 7 -05 section 15.5.3) (See page 1 for additional info) I= 1. 0, hn= 15'- 0", Ct= .02,x= .75, T C „ = .152,R =2 C S ( S DS 49 V= C =.49W Tube Steel Beams — HSS4x4x1 /4 F = 46 ksi, S = 3.90 in w = 12 plf 1/2” Glass Weight = 8 psf Soffit framing + finish weight = 8 psf Span (worst case) = 13' -6" w = .7( (8 psf)(16' -0 ") + (8 psf)(5'-0 ")+ (2)(12 pif)) = 90 plf Seismic lateral load = .49w = 44 plf Mmax = (1/8)(44 plf)(13' -6 ") = 1.00 k -ft = 12.0 k -in f = M /S = ( 12.0 k -in) /(3.90 in = 3.08 ksi < Fb = .6F = 27.6 ksi Tube Steel Columns — HSS4x4x1 /4 Total Seismic Load = (44 plf)(36 ft) = 1584 Ibs Seismic shear load per column = (1/6)(1584 Ibs) = 264 Ibs Base moment = (264 Ibs)(15' -0 ") = 3.96 k -ft = 47.5 k -in f = M /S = (47.5 k -in) /(3.90 in = 12.2 ksi < Fb = .6F = 27.6 ksi (see attached for base anchorage design) 5 O.K. Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington O.K. O.K. LEWIS ENGINEERING INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD. SUITE 5 COLUMBUS, OH 43220 Ph: 614- 326 -2806 Fx: 614- 326 -2805 Storefront Framing (cont'd) Box Beams — (2) 4 "x16 GA box beams ' / %" Glass Weight = 8 psf Span (worst case) = 10' -0" Lateral Load w = 1 /2 (8 psf)(14' -6 ") = 41 plf Seismic lateral load = E = .7(.49w) = 20 plf Mmax (lateral) = (118)(20 plf)(10' -0 ") = . 25 k -ft < Mallow = 2.178 k -ft (ESR -2215) Vertical Load w = (8 psf)(4' -0 ") = 32 pif Mmax (vertical) = (1/8)(32 plf)(10' -0 ") = . 4 k -ft < Mallow = 2.483 k -ft (ESR -2215) Structural Calculations Champs Sports Southcenter Mall Tukwila, Washington O.K. O.K. User application PROFIS Anchor 1.11.20 httn: /Awm..ushi Iti .com! Company. Lewis Engineering Inc. Specifier. SMD Address Phone/Fax: -/- E -Mail: Sheet 7 Projed: Contract No.: laspons ble: Location/Date: -/ 12/2/2008 Specifiers torments: Anchor type and size: Kwik Bolt 3 (KB3) 3/4 Effedive embedment depth: h 5.59 in. Material: Carbon Steel Proof: Standoff installation: Anchor plate: Base material: Reinforcement Anchor Loading Goveming loads[I b, in.-lb] N =0 Mp 0 desgnmethod: lilt ASD from lilti Product Technical Guide e = 0.00 in. (no stand-oft); t = 0.50 in. CUSTOM; f =36000 pa; I 10.00x10.00x0.50in. unaacled concrete 3000, f = 3000 pa; h = 8.00 in. Geometry fin,l plan view O 393.70 3 A O 4 0 0 7.50 2 393.70 y x secti A 4 m c 0 U 93 section A t:150 h =5.59 x section B v 0 M 48384 4 7 Z2Y. V 288 M? 0 Goveming loads[lb, in.-lb] N v v M. M M, 0 268 0 0 48384 0 Eccentricity (structural section) [in.] e = 0.00; e = 0.00 Input data and results must be checked for agreement with the existing con0tions and be plausibility! PRGFIS Anchor( c ) 2003 Hilti AG, FL-0494 Schaan Hilti is a registered Trademark of Hilt AG, Schaan Il i II Userapplication PROFIS Anchor 1.11.20 Company: Levis Blgineering Inc. Sheet 8 Spedfier: SMD Project: Address Contract Kb.: Phone/Fax: -/ - Fevondble: JULtammuabilami E-Mail: Location/Date: -/ 12/2/2008 Load case (governing): Anchor reactions obi Tension force: (+Tendon -Pressure) 0 3 4 Tendon Compression * 1 1 Anchor Tendon force Shear force •- N el a 3051 0 3051 0 67 67 67 67 max. conaete compressive strain NI: 0.13 max. concrete compressive dress [pd]: 498 resifting tendon force [Ib]: 6104 resifting compredzion force [Ib]: 6104 Loads on the critical anchor 1 Design values [lb] Utilization [%] Proof Load Strength ON/Ov Status Tendon load 3052 3102 98 / - OK Shear load (no bending) 67 4782 -/ 1 OK Contained torsion and shear loads 0 N 0 V a Uilization I NV [ Status 0.984 0.014 1.667 97 OK 13;1+1 Details fAN f A3/ fRN fR I nd shew.thread 0.617 0.896 1.000 1.000 0 . 0: llear thibugh the bolt 1: shear through the threads all Nalb] all V[lb] all N all V, all M[in.-lb] NNAlbl V„,p b] 5030 5340 - - 2455 3102 4782 Fastening meets the design criteria! Input data and results must be chected for agreement with the misting conditions and for plausibility! PROFIS Anchor( c )2003 Hilt AG, FL4494 Schaan Hint is a registered Ttedemantol KM AG. Schaan �, User application PROFIS Anchor 1.1120 C1 Company. Lewis Engineering Inc. Sheet9 Specifier. SMD Project: Address Contract No.: Phone/Fax: -/ - Fesponsble: h(Tp: //wvwv.ushiIti.com! E-Mail: Location/Date: -/ 12/2/2008 Anchorplats, steel: C 1DM; f = 36000 psi Section type: Square hol low sedion - liSS4X4X25 (4.00 x 4.00 x 0.25) I- ble diameter d, =0.81 in. Recommended plate thickness: not calculated A y 0 3 0 0 N N x 4 0 0 0 . 0 0 0 in 0 00 1 2 n! 1.250 1.250 5.000 5.000 [n] y x y Coorcinates Anchor (in] Anchor x y Anchor x y Anchorpiate x 1 -3.75 -3.75 3 -3.75 3. 75 -5.00 5.00 5.00 -5.00 2 3.75 -3.75 I 4 3.75 3.75 5.00 5.00 -5.00 5.00 Input data and results must be checiad for agreementwith the existing conddone and for plausibility) PRCFIS Anchor( c ) 2003 Hilfi AG, FL-9494 Schaan Hila is a registered Trademarkaf Mb AG, Schaan November 17, 2008 Jennifer Mireles 1327 Post Ave #H Torrance, CA 90501 Dear Ms. Mireles, Fire Department: Sincerely, 1- R o :a Bill Rambo Permit Technician encl File No. D08 -485 • city of Tukwila If you have any questions, please contact me at (206) 431 -3670. Department of Community Development Jack Pace, Director RE: CORRECTION LETTER #1 Development Application Number D08 -485 Champs -1030 Southcenter Mall P:\Pennit Center\Correction Letters \2008\D08 -485 Correction Ltr #1.DOC wer This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building and Fire Departments. Building Department: Allen Johannessen at 206 - 433 -7163 if you have questions regarding the attached comments. Al Metzler at 206 -575 -4404 if you have questions regarding the attached comments. 1) Provide a floor plan which details shelving locations 2) Indicate on plans what exact maximum storage height is to be Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 Building Division Review Memo Date: November 7, 2008 Project Name: Champs Permit #: D08 -485 Plan Review: Allen Joharmessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner • • The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a floor plan for the shelving. S1.0 sheet provided with the shelving permit is not applicable; eliminate S1.0 sheet from the shelving permit. Only provide sheets specifically relative to the shelving permit. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: D08 -485 DATE: 12 -10 -08 PROJECT NAME: CHAMPS SITE ADDRESS: 1030 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Public Works ❑ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-11-08 Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROICJTING: Please Route REVIEWER'S INITIALS: 0 PER D �� , 4 * PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 Incomplete Structural Review Required Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: 6)) A'Wv t2 -/ . -05 Fire Prevention u DATE: DATE: Planning Division Permit Coordinator Not Applicable ❑ No further Review Required n DUE DATE: 01 -08 -09 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 - 485 DATE: 11 - - PROJECT NAME: CHAMPS SITE ADDRESS: 1030 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMEN to,i , Oke Building Division Public Works PERMIT COORD COPY 44 PLAN REVIEW /ROUTING SLIP DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 ill 1440 )Il -o) Fire Prevention Structural ❑ Incomplete ❑ DATE: DATE: Planning Division Permit Coordinator DUE DATE: 11-06-08 Not Applicable Permit Center Use Only . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ DUE DATE: 12-04 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire Ping ❑ PW ❑ Staff Initials: Date: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www,ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: CHAMPS Project Address: 1030 SOUTHCENTER MALL Contact Person: 3 G 0 )E L 5 Phone Number: 644 - 724. -2166 Summary of Revision: Plan Check/Permit Number: D08-485 Sheet Number(s): 5 ` -6 "Cloud" or highlight all areas of revision including date of rev lo vw r I Received at the City of Tukwila Permit Center by: 10— Entered in Permits Plus on LI— t 0 K \application\ ooms- applications co line4evision submittal Steven M. Mullet, Mayor Steve Lancaster. Director RECEIVED arvOF T'UKWIIA I DEC 10 2000 PgRAA'T CENTCR Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS a SURETY CO 104644232 11/10/2005 Until Cancelled $12,000.00 11 /18/2005 Name Role Effective Date Expiration Date LISCHKA, STEPHEN C PARTNER /MEMBER 11/18/2005 Amount Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 CENTRAL MUTUAL CLP8454110 07/11/2008 07/11/2009 $1,000,000.0007 /15/2008 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L&tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company LEtLRETAIL CONSTRUCTION LLC 4053602775 3750 W MAIN ST STE 4A NORMAN OK 73072 OUT OF STATE LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602372596 ACTIVE LLRETCL954QQ CONSTRUCTION CONTRACTOR 11/18/2005 11/30/2009 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • 0 Page 1 of 2 https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= LLRETCL954QQ 01/15/2009 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 2'X12' 4'X12' 4' 4' 4'X12' 4' 4' 4' 4' 4'X12' 4' 4'X12' 4'X12' 2'X12' 4' 4' 4' 4' 4' 4' 4' 4' 3' -9 1/4" UTILITY CH -MW5 4'x12' (5514) TRAININC1 4'x12' (55H) 3' C1-4-M1-15 C1-4-M1-15 C1-4-M1-15 ' 4' L' X 12' 4' 4' DOUBLE 1-IUNG APP. 4' 4' 7 4'X12' 4' 4'__L2 2 4' 4'X12' 4' DOUBLE HUNCH APP. 1 EV0MMA )(o)M1 �LrIJ 4'X12' 4' 4'X12' 4' 4' D U5LE 4' 4' DOUBLE 1-IUNG APP. 4' 4'X12' 4' 4' 4' 4' 4' 4' 4' 4'X12' 4' 4' 4' 4'X12' 4' 3' 12'X12' 4' L' X IT 4' 4 ' X-122 4' 4' 4' 4' 4' 'X12' 4' 4'X12' 4' 4' 4'X12' 4' 4'X12' 4' 4' 4' 4' 4'X12' 3' 3' 1 4' 4' 4'X12' 1 4'X12' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' X 12' 2'X12' (NATION e exit dis t shall be din . s ace served by the e mean c egress illumination level shit 44 be less than 1 oot =car at the wlkin ag Ievelj 1 C 1006. 11 umination emergency pow 3 he powe : upply for means of egress ills. r ination shall normally bi F ovided by the premises' elects iCE I u In the ever t ( f power supply failure, an er i arc E ncy electrical system shy II . utomatically illuminate the fo I )w r g areas: 1. Aisle a d unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements 5. Exterior laAdjngs ;';for 'exit'djkcharge'_ MEANS OF EGRESS ILL IBC 1 06.1 Illumination required The n can of egress, including illumi ated at all times I the buil means of a ress i IBC 4 S1.0 0 w w X 1/2" = 1' -0" M` _r(o)gM RIM 6" = 1' -0" D) 4' -0" COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1/4" DIA. BOLT EA. END METAL SHELVING UNIT "T" UPRIGHT a 0_ 0 w X 0 4 M ]LaIRTIR °J(o)I MMmm D 1 3/32" t = 14 GA 0 0 J Li 0 0 0 1- 0 0 J 1- 0 D z M z 0 o� N 'TYPE 1 - DOUBLE RIVET 2r 3' -0" OR 2' -0" i:M °, M (0)M E D) COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. \ BRACE ATTACHMENT 1 LOCATION (TYP.) TYP. 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END (TYP.) METAL SHELVING UNIT "T" UPRIGHT TYPE 2 - DOUBLE RIVET LOW PROFILE LM TYP. S1.0/ 0 w w V) X rs 51.0 NOTES: 1. REF. ARCH. FIXTURE PLAN FOR SHELVING PLAN LAYOUT. 2. WHEN SHELVING UNIT IS INSTALLED AGAINST WALL, ANCHOR UNIT TO FLOOR & ATTACH TO WALL @ TOP AND EVERY 4' -0" O.C. A.F.F. T -SHAPE POST �J� JIEVZIMI 1 6" = 1 -0" 4' -0" COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END METAL SHELVING UNIT "T" UPRIGHT 14 "x1a "x$" THICK CLIP ANGLE x 3" LONG SHELVING UNIT UPRIGHT z cL 0 CC X ; "o TEK SCREW (TYP.) 3000 PSI CONCRETE - 4" MINIMUM THICKNESS (2) 1/4" DIA. X 2" EMBED. HILTI KWIK BOLT 3 EXPANSION ANCHOR (ICC# ESR -1385, COLA #RR25577, (SPECIAL INSPECTION NOT REQUIRED) U 0 J STRUCTURAL NOTES: A. GENERAL 1. THE STRUCTURE IS DESIGNED TO BE SELF - SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER THE COMPLETION OF THE PROJECT. 2. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. 3. EQUIPMENT FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO HVAC, PLUMBING, OR ELECTRICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF THE INVOLVED TRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. EXCESS COST RELATED TO VARIATION IN THESE REQUIREMENTS TO BE BORNE BY THE APPROPRIATE CONTRACTOR. 4. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN. 5. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR AND SHALL CONFORM TO THOSE SHOWN ON THE ARCHITECTURAL DRAWINGS. 6. EXISTING BUILDING: PROVIDE TEMPORY SUPPORTS AND OTHER MEASURES AS REQUIRED TO PREVENT DAMAGE TO THE EXISTING BUILDING DURING CONSTRUCTION. FIELD VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS WHICH AFFECT THE NEW CONSTRUCTION. B. GOVERNING CODE: 2006 INTERNATIONAL BUILDING CODE 1. EARTHQUAKE DESIGN DATA: A. SEISMIC IMPORTANCE FACTOR = 1.0 B. SEISMIC USE GROUP = 1 C. Ss = 1.473, Sr =0.507 E. SITE CLASS = D F. Sos = .982, Sol = .507 G. SEISMIC DESIGN CATEGORY = D F. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE 2. INTERIOR LATERAL LOAD = 5 PSF C. STRUCTURAL STEEL 1. MATERIALS: A. SQUARE & RECTANGULAR TUBING: ASTM A500, FY = 46 KSI HIGH STRENGTH BOLTS: ASTM A325 OR A490 ANCHOR BOLTS: ASTM A307 OR A36 EXPANSION ANCHORS: HILTI "KWIK BOLT II's" OR APPROVED EQUA WELDING ELECTRODES: SERIES E70. 2. SPECIFICATIONS: A. WELDING PERSONNEL AND PROCEDURES ARE TO BE QUALIFIED PER AWS D1.1. UNLESS SPECIFICALLY SHOWN OTHERWISE, DESIGN, FABRICATION AND ERECTION TO BE GOVERNED BY: 1 . AISC ASD SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (JUNE 1 , 1 989). 2. AISC CODE OF STANDARD PRACTICE (MARCH 7, 2000). 3. STRUCTURAL WELDING CODE, AWS D1.1 -2002 OF THE AMERICAN WELDING SOCIETY. 4. SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS (JUNE 23, 2000). 3. CONNECTIONS: A. FOLLOW INSTRUCTIONS ON DRAWINGS FOR GENERAL ARRANGEMENT OR PARTICULAR DETAILS. FIELD CONNECTIONS NOT OTHERWISE NOTED TO BE BOLTED. SHOP CONNECTIONS NOT OTHERWISE NOTED TO BE WELDED OR BOLTED. CONNECTIONS TO BE DESIGNED BY THE FABRICATOR TO DEVELOP FULL STRENGTH OF MEMBER. 4. PAINT: A. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED; ASPHALTIC PAINTS ARE NOT ACCEPTABLE. 5. GALVANIZING: A. ALL SHELF ANGLES, LINTELS IN EXTERIOR WALLS, AND ALL EXTERIOR STEEL EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. REVISIONS N changes shall be made to thel scope 1 of work without prior app Tukwila Building Division. ' NOTE: Revisions will require a new i w fee ittai and rnay include additional plan SEPARATE PERMIT REQUIRED FOR: Mechanical VIElectrical �� umbing G as Piping City of Tukwila BUILDING DIVISION 3' -0" OR 2' -0" 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END (TYP.) COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) METAL SHELVING UNIT "T" UPRIGHT Pl r review approval Is subject to errors and om!ssfons. Appro 1 of construction documents does not authorize the violation of any adopted code or ordinanco. R z ipt 0{ approved Field Copy and conditions is acr'J or l cified: COPY Permit No Date: City of Tukwila . BU opir D "f S!O INTERMEDIATE SHELF BEAM ATTACH W/ 1/4 "0 BOLTS EACH END 3/4 "X16 GA. FLAT STRAP SHELVING POST _ U/r=2) U /1\g RE V LI 6. MISCELLANEOUS: A. PROVIDE HOLES FOR OTHERS. IF OPENING IS NOT SHOWN ON THE STRUCTURAL DRAWINGS, OBTAIN PRIOR APPROVAL. B. GROUT UNDER BEARING PLATES, BASE PLATES, AND SETTING PLATES TO BE NON- SHRINKING TYPE. C. STEEL BELOW GRADE TO BE PROTECTED BY A MINIMUM OF 3 INCHES OF CONCRETE. D. PROVIDE HEAVY WASHERS AT ALL ANCHOR BOLTS. E. FINISH ENDS OF ALL COLUMNS, STIFFENERS, AND ALL OTHER MEMBERS IN DIRECT BEARING. F. EMBEDMENT LENGTH OF EXPANSION BOLTS INTO SOLID MASONRY OR CONCRETE SHALL BE AS FOLLOWS: 1/2 INCH DIAMETER BOLTS - -- 2 1/4 INCHES EMBEDMENT 5/8 INCH DIAMETER BOLTS - -- 2 3/4 INCHES EMBEDMENT D. LIGHTGAGE METAL FRAMING 1. MATERIALS A. STUDS AND TRACKS: ASTM A446 GRADE D, Fy = 33 KSI. 2. SPECIFICATIONS: A. WELDING PERSONNEL AND PROCEDURES ARE TO BE QUALIFIED PER AWS. DESIGN, FABRICATION, AND ERECTION TO BE GOVERNED BY LATEST REVISIONS OF: 1. AISC SPECIFICATIONS OF THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS. 2. STRUCTURAL WELDING CODE, AWS D1 .3 -98 OF THE AMERICAN WELDING SOCIETY. 3. PROPERTIES: A. LIGHTGAGE FRAMING MEMBERARE BASED ON CSJ (1 5/8" FLANGE) STUDS WITH DIETRICH INDUSTRIES SECTION PROPERTIES AND ALLOWABLE RESISTING MOMENT CAPACITY. ALTERNATE MANUFACTURES'S FRAMING SIZES SHALL MEET THE MINIMUM SECTION PROPERTIES AND ALLOWABLE RESISTING MOMENT CAPACITY OF THE MEMBERS INDICATED ON THE DESIGN DRAWINGS. 4. CONNECTIONS A. ALL CONNECTIONS TO BE #10 TEK SCREWED OR FIELD WELDED. 5. FINISH: A. ALL MATERIALS TO BE GALVANIZED COATED IN ACCORDANCE WITH ASTM A525 G -6 B. TOUCH UP FIELD WELDS WITH ZINC RICH PAINT. 6. MISGELANEOUS: ' A. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION B. DEFLECTION LIMIT •= L/36 C. ALL FIELD CUTTING TO BE PERFORMED WITH A SAW. D. WELD SIZES TO BE 3/32" WITH AWS TYPE 6013 OR 7014 ROD. E. TRACKS TO BE SECURELY ANCHORED TO THE SUPPORTING STRUCTURE. F. PROVIDE CONTINUOUS HORIZONTAL BRIDGING AT 4' -0" O.C. MAXIMUM FOR WALLS G. PR RV DOUBLE STUDS UNDER BEAM AND LINTEL BEARING, UNLESS SHOWN E. WELL JN RWISE. 1. REFERENCES: A. AWS D1.1-2002 - "STRUCTURAL WELDING CODE - STEEL" B. AWS D1.3 -98 - "STRUCTURAL WEDLING CODE - SHEET STEEL" F. SPEC 1. SPECIAL INSPECTION IS TO BE PROVIDED IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE DEPARTMENT OF BUILDING SAFETY AND SHALL NOT BE CONSTRUED TO RELIEVE THE OWNER OR THEIR AUTHORIZED AGENT FROM REQUESTING THE PERIODIC AND CALLED INSPECTIONS REQUIRED BY THE BUILDING CODE. SPECIAL INSPECTIONS SHALL BE PAID BY THE OWNER. 2. REQUIRED SPECIAL INSPECTIONS: A. IN ADDITION TO THE REGULAR INSPECTIONS, THE FOLLOWING ITEMS WILL ALSO REQUIRE SPECIAL INSPECTIONS IN ACCORDANCE WITH THE BUILDING CODE. 1. FIELD WELDING 2. HIGH STRENGTH BOLTS B. SPECIAL INSPECTOR SHALL MEET THE QUALIFICATIONS AS STATED IN THE BUILDING CODE AND SHALL PERFORM THE DUTIES AND RESPONSIBILITITES AS OUTLINED IN THE BUILDING CODE. "T" UPRIGHT O DOUBLE RIVET DOUBLE RIVET SHELF MATERIAL (PARTICLE BOARD) ING BY_,AWS QUALIFIED OPERATORS. NOTE: Install masonite end panels on end shelving units. 51.0 NO SCALE SHELVING \OT 5. EARTHQUAKE DESIGN DATA: A. SEISMIC IMPORTANCE FACTOR I = 1.0 B. Ss = 1.473, Si = .507 C. SITE CLASS = D (ASSUMED) D. Sos = .982, Sol = .507 E. SEISMIC DESIGN CATEGORY = D 1/4 NUT MASONITE ES (3 0- {fi(o)MM °-�U(o)m or4 CORRECTION 1/4 WASHERS 1 /4" DIA. BOLT TYP. TYP. EACH CORNER TYP. EACH LEVEL TYP. TYP. TYP. SHELVING IS 1 2' HIGH MAX. W/ w/ 8 SHELVES / 7 OPENINGS PARTICLE BOARD SHELVES. • 1. LIGHT DUTY STORAGE UNITS DESIGNED PER THE 2006 INTERNATIONAL BUILDING CODE. 2. STORAGE CAPACITY: 40# PER LEVEL 3. POST LOAD SIGN AT CONSPICUOUS LOCATIONS DEPICTING THE DESIGN CAPACITY OF THE RACK USING PERMANENT PLAQUE NOT LESS THE 50 SQ. INCHES 4. MATERIALS: A. UNIT MEMBERS: ASTM A570, Fy = 36 KSI MIN. B. BOLTS: ASTM A307 C. WELD ELECTRODES: SERIES E70 D. WEDGE ANCHORS: HILTI KWIK BOLT 3 WEDGE ANCHOR (ESR -1385, COLA #RR25577) OR APPROVED EQUAL 6. CONCRETE TO BE MIN. 4" THICK NORMAL - WEIGHT WITH A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI X68 - 1 -i 8,5 DATE: 10 -30 -08 JOB NO: 5857 DRAWN: RCH CHECKED: SMD GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. ENGINEER: LEWIS ENGINEERING, - INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD., SUITE 5 Columbus, Ohio 43220 (614) 326 -2806 (PH) (614) 326 -2805 (FAX) STORE NO. z uJ 0 0 0 REVISIONS RECEIVED DEC 10 PERMIT CANTER SHEET NUMBER z Champs: 14498 NO. 1 DESCRIPTION LL COMMENTS /OWNER CHANGES DATE 12/03/08 SHELVING SEISMIC DETAILS AND GEN. STR. NOTES S1.0 Y / 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 2'X12' 4'X12' 4' 4' 4'X12' 4' 4' 4' 4' 4'X12' 4' 4'X12' 4'X12' 2'X12' 4' 4' 4' 4' 4' 4' 4' 4' 3' -9 1/4" UTILITY CH -MW5 4'x12' (5514) TRAININC1 4'x12' (55H) 3' C1-4-M1-15 C1-4-M1-15 C1-4-M1-15 ' 4' L' X 12' 4' 4' DOUBLE 1-IUNG APP. 4' 4' 7 4'X12' 4' 4'__L2 2 4' 4'X12' 4' DOUBLE HUNCH APP. 1 EV0MMA )(o)M1 �LrIJ 4'X12' 4' 4'X12' 4' 4' D U5LE 4' 4' DOUBLE 1-IUNG APP. 4' 4'X12' 4' 4' 4' 4' 4' 4' 4' 4'X12' 4' 4' 4' 4'X12' 4' 3' 12'X12' 4' L' X IT 4' 4 ' X-122 4' 4' 4' 4' 4' 'X12' 4' 4'X12' 4' 4' 4'X12' 4' 4'X12' 4' 4' 4' 4' 4'X12' 3' 3' 1 4' 4' 4'X12' 1 4'X12' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' X 12' 2'X12' (NATION e exit dis t shall be din . s ace served by the e mean c egress illumination level shit 44 be less than 1 oot =car at the wlkin ag Ievelj 1 C 1006. 11 umination emergency pow 3 he powe : upply for means of egress ills. r ination shall normally bi F ovided by the premises' elects iCE I u In the ever t ( f power supply failure, an er i arc E ncy electrical system shy II . utomatically illuminate the fo I )w r g areas: 1. Aisle a d unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements 5. Exterior laAdjngs ;';for 'exit'djkcharge'_ MEANS OF EGRESS ILL IBC 1 06.1 Illumination required The n can of egress, including illumi ated at all times I the buil means of a ress i IBC 4 S1.0 0 w w X 1/2" = 1' -0" M` _r(o)gM RIM 6" = 1' -0" D) 4' -0" COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1/4" DIA. BOLT EA. END METAL SHELVING UNIT "T" UPRIGHT a 0_ 0 w X 0 4 M ]LaIRTIR °J(o)I MMmm D 1 3/32" t = 14 GA 0 0 J Li 0 0 0 1- 0 0 J 1- 0 D z M z 0 o� N 'TYPE 1 - DOUBLE RIVET 2r 3' -0" OR 2' -0" i:M °, M (0)M E D) COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. \ BRACE ATTACHMENT 1 LOCATION (TYP.) TYP. 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END (TYP.) METAL SHELVING UNIT "T" UPRIGHT TYPE 2 - DOUBLE RIVET LOW PROFILE LM TYP. S1.0/ 0 w w V) X rs 51.0 NOTES: 1. REF. ARCH. FIXTURE PLAN FOR SHELVING PLAN LAYOUT. 2. WHEN SHELVING UNIT IS INSTALLED AGAINST WALL, ANCHOR UNIT TO FLOOR & ATTACH TO WALL @ TOP AND EVERY 4' -0" O.C. A.F.F. T -SHAPE POST �J� JIEVZIMI 1 6" = 1 -0" 4' -0" COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END METAL SHELVING UNIT "T" UPRIGHT 14 "x1a "x$" THICK CLIP ANGLE x 3" LONG SHELVING UNIT UPRIGHT z cL 0 CC X ; "o TEK SCREW (TYP.) 3000 PSI CONCRETE - 4" MINIMUM THICKNESS (2) 1/4" DIA. X 2" EMBED. HILTI KWIK BOLT 3 EXPANSION ANCHOR (ICC# ESR -1385, COLA #RR25577, (SPECIAL INSPECTION NOT REQUIRED) U 0 J STRUCTURAL NOTES: A. GENERAL 1. THE STRUCTURE IS DESIGNED TO BE SELF - SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER THE COMPLETION OF THE PROJECT. 2. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. 3. EQUIPMENT FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO HVAC, PLUMBING, OR ELECTRICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF THE INVOLVED TRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. EXCESS COST RELATED TO VARIATION IN THESE REQUIREMENTS TO BE BORNE BY THE APPROPRIATE CONTRACTOR. 4. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THESE STRUCTURAL NOTES, THE SPECIFICATIONS, OR WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN. 5. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR AND SHALL CONFORM TO THOSE SHOWN ON THE ARCHITECTURAL DRAWINGS. 6. EXISTING BUILDING: PROVIDE TEMPORY SUPPORTS AND OTHER MEASURES AS REQUIRED TO PREVENT DAMAGE TO THE EXISTING BUILDING DURING CONSTRUCTION. FIELD VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS WHICH AFFECT THE NEW CONSTRUCTION. B. GOVERNING CODE: 2006 INTERNATIONAL BUILDING CODE 1. EARTHQUAKE DESIGN DATA: A. SEISMIC IMPORTANCE FACTOR = 1.0 B. SEISMIC USE GROUP = 1 C. Ss = 1.473, Sr =0.507 E. SITE CLASS = D F. Sos = .982, Sol = .507 G. SEISMIC DESIGN CATEGORY = D F. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE 2. INTERIOR LATERAL LOAD = 5 PSF C. STRUCTURAL STEEL 1. MATERIALS: A. SQUARE & RECTANGULAR TUBING: ASTM A500, FY = 46 KSI HIGH STRENGTH BOLTS: ASTM A325 OR A490 ANCHOR BOLTS: ASTM A307 OR A36 EXPANSION ANCHORS: HILTI "KWIK BOLT II's" OR APPROVED EQUA WELDING ELECTRODES: SERIES E70. 2. SPECIFICATIONS: A. WELDING PERSONNEL AND PROCEDURES ARE TO BE QUALIFIED PER AWS D1.1. UNLESS SPECIFICALLY SHOWN OTHERWISE, DESIGN, FABRICATION AND ERECTION TO BE GOVERNED BY: 1 . AISC ASD SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (JUNE 1 , 1 989). 2. AISC CODE OF STANDARD PRACTICE (MARCH 7, 2000). 3. STRUCTURAL WELDING CODE, AWS D1.1 -2002 OF THE AMERICAN WELDING SOCIETY. 4. SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS (JUNE 23, 2000). 3. CONNECTIONS: A. FOLLOW INSTRUCTIONS ON DRAWINGS FOR GENERAL ARRANGEMENT OR PARTICULAR DETAILS. FIELD CONNECTIONS NOT OTHERWISE NOTED TO BE BOLTED. SHOP CONNECTIONS NOT OTHERWISE NOTED TO BE WELDED OR BOLTED. CONNECTIONS TO BE DESIGNED BY THE FABRICATOR TO DEVELOP FULL STRENGTH OF MEMBER. 4. PAINT: A. ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED; ASPHALTIC PAINTS ARE NOT ACCEPTABLE. 5. GALVANIZING: A. ALL SHELF ANGLES, LINTELS IN EXTERIOR WALLS, AND ALL EXTERIOR STEEL EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. REVISIONS N changes shall be made to thel scope 1 of work without prior app Tukwila Building Division. ' NOTE: Revisions will require a new i w fee ittai and rnay include additional plan SEPARATE PERMIT REQUIRED FOR: Mechanical VIElectrical �� umbing G as Piping City of Tukwila BUILDING DIVISION 3' -0" OR 2' -0" 3/4" X 16 GA. DIAGONAL BRACE @ EACH VERT. SECTION ON REAR FACE ONLY. ATTACH W/ 1 /4" DIA. BOLT EA. END (TYP.) COMPOSITE WOOD SHELF W/ METAL EDGE @ DIAG. BRACE ATTACHMENT LOCATION (TYP.) SECURE WALL SHELVING TO CONT. HORIZ. FURRING @ PERIMETER WALL. COMPOSITE WOOD SHELF W/ METAL EDGE CONNECTED TO UPRIGHT, ADJUSTABLE SHELF HEIGHT (TYP.) METAL SHELVING UNIT "T" UPRIGHT Pl r review approval Is subject to errors and om!ssfons. Appro 1 of construction documents does not authorize the violation of any adopted code or ordinanco. R z ipt 0{ approved Field Copy and conditions is acr'J or l cified: COPY Permit No Date: City of Tukwila . BU opir D "f S!O INTERMEDIATE SHELF BEAM ATTACH W/ 1/4 "0 BOLTS EACH END 3/4 "X16 GA. FLAT STRAP SHELVING POST _ U/r=2) U /1\g RE V LI 6. MISCELLANEOUS: A. PROVIDE HOLES FOR OTHERS. IF OPENING IS NOT SHOWN ON THE STRUCTURAL DRAWINGS, OBTAIN PRIOR APPROVAL. B. GROUT UNDER BEARING PLATES, BASE PLATES, AND SETTING PLATES TO BE NON- SHRINKING TYPE. C. STEEL BELOW GRADE TO BE PROTECTED BY A MINIMUM OF 3 INCHES OF CONCRETE. D. PROVIDE HEAVY WASHERS AT ALL ANCHOR BOLTS. E. FINISH ENDS OF ALL COLUMNS, STIFFENERS, AND ALL OTHER MEMBERS IN DIRECT BEARING. F. EMBEDMENT LENGTH OF EXPANSION BOLTS INTO SOLID MASONRY OR CONCRETE SHALL BE AS FOLLOWS: 1/2 INCH DIAMETER BOLTS - -- 2 1/4 INCHES EMBEDMENT 5/8 INCH DIAMETER BOLTS - -- 2 3/4 INCHES EMBEDMENT D. LIGHTGAGE METAL FRAMING 1. MATERIALS A. STUDS AND TRACKS: ASTM A446 GRADE D, Fy = 33 KSI. 2. SPECIFICATIONS: A. WELDING PERSONNEL AND PROCEDURES ARE TO BE QUALIFIED PER AWS. DESIGN, FABRICATION, AND ERECTION TO BE GOVERNED BY LATEST REVISIONS OF: 1. AISC SPECIFICATIONS OF THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS. 2. STRUCTURAL WELDING CODE, AWS D1 .3 -98 OF THE AMERICAN WELDING SOCIETY. 3. PROPERTIES: A. LIGHTGAGE FRAMING MEMBERARE BASED ON CSJ (1 5/8" FLANGE) STUDS WITH DIETRICH INDUSTRIES SECTION PROPERTIES AND ALLOWABLE RESISTING MOMENT CAPACITY. ALTERNATE MANUFACTURES'S FRAMING SIZES SHALL MEET THE MINIMUM SECTION PROPERTIES AND ALLOWABLE RESISTING MOMENT CAPACITY OF THE MEMBERS INDICATED ON THE DESIGN DRAWINGS. 4. CONNECTIONS A. ALL CONNECTIONS TO BE #10 TEK SCREWED OR FIELD WELDED. 5. FINISH: A. ALL MATERIALS TO BE GALVANIZED COATED IN ACCORDANCE WITH ASTM A525 G -6 B. TOUCH UP FIELD WELDS WITH ZINC RICH PAINT. 6. MISGELANEOUS: ' A. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION B. DEFLECTION LIMIT •= L/36 C. ALL FIELD CUTTING TO BE PERFORMED WITH A SAW. D. WELD SIZES TO BE 3/32" WITH AWS TYPE 6013 OR 7014 ROD. E. TRACKS TO BE SECURELY ANCHORED TO THE SUPPORTING STRUCTURE. F. PROVIDE CONTINUOUS HORIZONTAL BRIDGING AT 4' -0" O.C. MAXIMUM FOR WALLS G. PR RV DOUBLE STUDS UNDER BEAM AND LINTEL BEARING, UNLESS SHOWN E. WELL JN RWISE. 1. REFERENCES: A. AWS D1.1-2002 - "STRUCTURAL WELDING CODE - STEEL" B. AWS D1.3 -98 - "STRUCTURAL WEDLING CODE - SHEET STEEL" F. SPEC 1. SPECIAL INSPECTION IS TO BE PROVIDED IN ADDITION TO THE INSPECTIONS CONDUCTED BY THE DEPARTMENT OF BUILDING SAFETY AND SHALL NOT BE CONSTRUED TO RELIEVE THE OWNER OR THEIR AUTHORIZED AGENT FROM REQUESTING THE PERIODIC AND CALLED INSPECTIONS REQUIRED BY THE BUILDING CODE. SPECIAL INSPECTIONS SHALL BE PAID BY THE OWNER. 2. REQUIRED SPECIAL INSPECTIONS: A. IN ADDITION TO THE REGULAR INSPECTIONS, THE FOLLOWING ITEMS WILL ALSO REQUIRE SPECIAL INSPECTIONS IN ACCORDANCE WITH THE BUILDING CODE. 1. FIELD WELDING 2. HIGH STRENGTH BOLTS B. SPECIAL INSPECTOR SHALL MEET THE QUALIFICATIONS AS STATED IN THE BUILDING CODE AND SHALL PERFORM THE DUTIES AND RESPONSIBILITITES AS OUTLINED IN THE BUILDING CODE. "T" UPRIGHT O DOUBLE RIVET DOUBLE RIVET SHELF MATERIAL (PARTICLE BOARD) ING BY_,AWS QUALIFIED OPERATORS. NOTE: Install masonite end panels on end shelving units. 51.0 NO SCALE SHELVING \OT 5. EARTHQUAKE DESIGN DATA: A. SEISMIC IMPORTANCE FACTOR I = 1.0 B. Ss = 1.473, Si = .507 C. SITE CLASS = D (ASSUMED) D. Sos = .982, Sol = .507 E. SEISMIC DESIGN CATEGORY = D 1/4 NUT MASONITE ES (3 0- {fi(o)MM °-�U(o)m or4 CORRECTION 1/4 WASHERS 1 /4" DIA. BOLT TYP. TYP. EACH CORNER TYP. EACH LEVEL TYP. TYP. TYP. SHELVING IS 1 2' HIGH MAX. W/ w/ 8 SHELVES / 7 OPENINGS PARTICLE BOARD SHELVES. • 1. LIGHT DUTY STORAGE UNITS DESIGNED PER THE 2006 INTERNATIONAL BUILDING CODE. 2. STORAGE CAPACITY: 40# PER LEVEL 3. POST LOAD SIGN AT CONSPICUOUS LOCATIONS DEPICTING THE DESIGN CAPACITY OF THE RACK USING PERMANENT PLAQUE NOT LESS THE 50 SQ. INCHES 4. MATERIALS: A. UNIT MEMBERS: ASTM A570, Fy = 36 KSI MIN. B. BOLTS: ASTM A307 C. WELD ELECTRODES: SERIES E70 D. WEDGE ANCHORS: HILTI KWIK BOLT 3 WEDGE ANCHOR (ESR -1385, COLA #RR25577) OR APPROVED EQUAL 6. CONCRETE TO BE MIN. 4" THICK NORMAL - WEIGHT WITH A 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI X68 - 1 -i 8,5 DATE: 10 -30 -08 JOB NO: 5857 DRAWN: RCH CHECKED: SMD GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. ENGINEER: LEWIS ENGINEERING, - INC. CONSULTING STRUCTURAL ENGINEERS 2000 W. HENDERSON RD., SUITE 5 Columbus, Ohio 43220 (614) 326 -2806 (PH) (614) 326 -2805 (FAX) STORE NO. z uJ 0 0 0 REVISIONS RECEIVED DEC 10 PERMIT CANTER SHEET NUMBER z Champs: 14498 NO. 1 DESCRIPTION LL COMMENTS /OWNER CHANGES DATE 12/03/08 SHELVING SEISMIC DETAILS AND GEN. STR. NOTES S1.0 I5' -(o" A.F.F. HSS4x4x4 14' - 6 " A.F.F. ATTACH TRACK /STUD TO TUBE WITH (2) .145" DIA. FASTENERS a 16" O.C. 13'-0" A.F.F. 38 "x18 GA. STUD FRAMING a 16" O.G. (TYP. U.N.O.) (4) #10 TEKS SCREWS (TYP.) I0' -0" A.F.F. LEASE LINE (2) #10 TEKS EACH SIDE 10 TEK SCREW INTO JOIST AT EACH END ROOF JOIST BEYOND I/8 HS52Zx2zx4 6 4S" o.c. MAX. 33 "x18 GA. STUD BRACE 6 48" O.G. 16 GA. FRAMING CLIP. ATTACH TO BEAM UITH ( .145" DIA. P.A.F. 3 Lir'n 3/4" = 1' -0" 6 � 3/4" = 1' -0 STUD COLUMN - (2) 3 -5/8 "x18 GA. STUDS BOXED WITH 3 -5/8 "x18 GA. TRACKS. SEE 1/S2.0. BOX BEAM (LOW - SEE V-10" l'-0" 6 " -I8 GA STUD (TYP. OF 2) HSS4x4x4 8 x47HtG 1 ATTACH TRACK TO TUBE WITH (2) .145" DIA. FASTENERS 16" O.C. 9'-0 I /S" 16 GA TRACK ATTACHED TO ROOF JOIST'WITH (2) 10 TEKS TOP 4 BOTTOM. SEE 8/S2.0 SECTIONS) 11' -4 3/8" 33 "x18 GA. STUD BRACE 48" O.G. (4) #10 TEKS EXIST'G STRUCTURE BEAMS V.IF. STUD BRACE FROM BELOW 23' -3" O'V'(o) 1/ = 1' — BOX BEAM: (2) 6 " -IS GA STUDS BOXED WITH 3- 5/8 " -I8 GA TRACKS TOP 4 BOTTOM. SEE 1/52.0 FOR BEAM CONSTRUCTION. ATTACH BEAM TO ROOF JOISTS AT EACH END PER DETAIL 8/52.0 16 GA. FRAMING CLIP. ATTACH TO BOX BEAM AND STUD BRACE WITH (4) #10 TEKS EACH. 1-15S4x4x4 COLUMN (TYP. OF 6) SEE DETAIL 2/S2.0 FOR BASE ATTACHMENT HS BOX BEAM • BOX BEAM: (2) fx16 GA. ST DS BOXED WITH 3- 518 "x16 GA TACKS TOP AND BOTTO SEE 1/52.0. ATTACH TO COLUMN BEYOND PER 9/S2.0 13' -6" 35' -I0 1/2" LEASE DIMENSION A.F.F. HSS4x4x4 0 14' - 6 " A.F.F. ATTACH TRACK /STUD TO TUBE WIN (2) .145" DIA. FASTENERS 6 16" O.C. 38"x18 GA. STUD FRAMING 6 16" O.C. (TYP. UN.0.) (4) #10 TEKS SCREWS (TYP.) 13' - 0" A.F.F. LEASE LINE I' -2 1/2" 16 GA. FRAMING CLIP. ATTACH TO BEAM WITH (4) .145" DIA. P.A.F. 3/ = 1' - 0" 1 -1/2" = 1' -0" 11' -6 5/8" Am. Am. HSS4x4x4 BOX BEAM (LOW - SEE SECTIONS) HSS4x4x4 145S4x4x (tG117 11' -5" 10' -3 5/8" ATTACH TRACK TO TUBE WITH (2) .145" DIA. FASTENERS a 16" 0.0, 130X BEAM: (2) 11 "x16 GA. STUDS BOXED WITH 3 -5 8 "x16 GA TRACKS TOP AND BOTTOM . SEE 1/S2.0. ATTACH TO COLUMN BEYOND PER 9/S2.0 1'-10" _ES 4 f- ROOF JOIST (2) "10 TEKS - TYP. TOP 4 BOTTOM 16 GA. TRACK (3) #10 TEKS EACH SIDE OF BEAM BOX BEAM STUD COLUMN - (2) 3 -5/8 "x18 GA. STUDS BOXED WITH 3 -5/8 "x18 GA. TRACKS. SEE 1/52.0. 38 "x18 GA. STUD BRACE 6 48" O.C. (4) #10 TEKS EXIST'G STRUCTURE BEAMS V.IF. 33 "x18 GA. STUD FRAMING a 16" O.C. lig' (o)M 1 -1/2" DEEP TRACK - WIDTH AS SPECIFIED. MATCH STUD GA. (TYP. TOP AND 150T) Qvvizacal[I: mow 2 "x18 GA. STUD FRAMING 16" O.C. 15' -6" AFF. LEASE LINE EXISTING TOPPING SLAB (2 -1/2" NICK) EXISTING STRUCTURAL SLAB (9 -I/2" THICK) BOX BEAM HSS4x4x4 I4'-3" A.F.F. " DIA. THREADED ROD -TYP OF 3 2"x18 GA. STUD FRAMING 0 16" O.C. 0 13' -0" AFF 33 "x18 GA. STUD FRAMING 6 16" O.C. (TYP. UN.0.) (4) #10 TEKS SCREWS (TYP.) REF. SIGN VENDOR r 38 "x18 GA. STUD BRACE 6 48" O.G. 16 GA. FRAMING CLIP. ATTACH TO BEAM WITH (4) .145" DIA. P.AF. STEEL COLUMN OR STUD COLUMN 33" X 16 GA. X 4" LG. TRACK W /2" LEG. SECURE TO COLUMN W /(2) ROWS OF(3) #10 TEK SCREWS SECURE TO BEAM WITH (3) "10 TEK SCREWS EACH SIDE. 2 I.30 1 -1 = I- 1A°J PJ 3/4" = 1' —O" U HSS4x4x4 ATTACH TRACK TO TUBE WITH (2) .145" DIA. FASTENERS a 16" O.C. HSS4x4x4 I I/4" 1 1/2" 11/4" (4) 10 TEKS 10 "x10 "xi" BASE PLATE (4) a" DIA. HILTI KWIK BOLT 3 (4) i" DIA. HILTI KWIK 50LT 3 ANCHORS W11H N" EMBED. INTO EXISTING STRUCTURAL SLAB. (EXISTING SLAB IS 9? THICK) NOTCH EXISTING TOPPING 5LAB A5 REQUIRED TO RECESS BASEPLATE ( +/ -22" IF NECESSARY, NOTCH STRUCTURAL SLAB AS REQUIRED). PROVIDE THIN LAYER OF GROUT FOR A SMOOTH LEVEL SURFACE. INFILL WITH NEW CONCRETE. EXIST'G STRUCTURE BEAMS V.IF. 38 "x18 GA. STUD BRACE 48" O.G. 38 "x18 GA. STUD FRAMING 0 16" O.C. BOX BEAM: (2) 4 "x16 GA. STUDS BOXED WITH 3 -5/8 "x16 GA TRACKS TOP AND BOTTOM. SEE 1/52.0. ATTACH TO COLUMN BEYOND PER 9/52.0 DATE: 10 -30 -08 JOB NO: 5857 DRAWN: RCH CHECKED: SMD GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. LEWIS ENGINEERING, INC. CONSULTING STRUCTURAL ENGINEERS STORE NO. ENGINEER: 2000 W. HENDERSON RD., SUITE 5 Columbus, Ohio 43220 (614) 326 -2806 (PH) (614) 326-2805 (FAX) Champs: 1 4498 REVISIONS SHEET NUMBER RECEIVED DEC 10 PERMIT CENTER STOREFRONT FRAMING PLAN AND SECTIONS DESCRIPTION LL COMMENTS /OWNER CHANGES 12/0