Loading...
HomeMy WebLinkAboutPermit D08-495 - WASHINGTON STATE NURSES ASSOCIATION - EXPANSION AND BUILD OUTWASHINGTON STATE NURSES ASSOCIATION 575 ANDOVER PK W 1308-495 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Phone: 2623049144 575 ANDOVER PK W TUKW Contractor: Name: S G A CORPORATION Address: 1501 N 200 ST , SHORELINE WA 98133 Phone: 206 778 -2191 Contractor License No: SGACO * *084BS DESCRIPTION OF WORK: TENANT IMPROVEMENT EXPANSION AND BUILDOUT Value of Construction: $14,000.00 Type of Fire Protection: AFA Type of Construction: V -B S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us WASHINGTON STATE NURSES ASSOCIATION 575 ANDOVER PK W , TUKWII,A WA SOUTHCENTER CORPORATE SQUAR 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 DEVELOPMENT PERMIT Contact Person: Name: TAMARA GENZALE Address: 635 ANDOVER PK W SUITE 107 , TUKVVILA WA 98188 Phone: 206 - 903 -0662 * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: Expiration Date: 01/10/2010 Fees Collected: International Building Code Edition: Occupancy per IBC: D08 -495 11/26/2008 05/25/2009 $506.93 2006 0008 doc: IBC -10/06 D08 -495 Printed: 11 -26 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: Print Name: C1/01 on Permit Number: D08 -495 Issue Date: 11/26/2008 Permit Expires On: 05/25/2009 Date: i1�GO 0 I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o e performance of work. I am authorized to sign and obtain this development permit. Date: 11 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D08 -495 Printed: 11 -26 -2008 Parcel No.: 2623049144 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 575 ANDOVER PK W TUKW WASHINGTON STATE NURSES ASSOCIATION 1: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: D08 -495 ISSUED 11/17/2008 11/26/2008 2: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 3: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 4: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 5: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 6: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 7: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 8: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 9: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 10: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 11: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 12: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) doc: Cond -10/06 1308 -495 Printed: 11 -26 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 13: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 14: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 16: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. 23: ** *BUILDING DEPARTMENT CONDITIONS * ** 24: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 25: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 26: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 27: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 28: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 29: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the doc: Cond -10/06 D08 -495 Printed: 11 -26 -2008 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 30: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 31: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. * *continued on next page ** doc: Cond -10/06 008 -495 Printed: 11 -26 -2008 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: � Date: k i I Print Name: , Ino� V V o1 n tV I eV doc: Cond -10/06 ordinances governing or local laws regulating D08 -495 Printed: 11 -26 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: %ii p ww. ci. tukwila. wa. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ■0-2kg t 4 [�� 4 om Site Address: 71 tJ w "t OaV� west Suite Number: 1 I ‘ Floor: I V Tenant Name: Wial'ti gtw State N V(c P /4' 1tY/'l New Tenant: ❑ Yes 4.. No Property Owners Name: �dJV� V CQJ(1 C�/I a•}e Iva V P < Vt /C, Mailing Address: 167 Anctovelr Pa {r- V'J tt s T-k- /)1 tot V\1A- 0 1(a / 5 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: - fiAIMGiYG1 Oet ut t-e Day Telephone: 2-Ob 03 - ObbZ Mailing Address: to INTOCAeV t VVesfi imi t- 1W-4/0 V\if* o[g Bg City State Zip Fax Number: ' 2.- C )1 = 2 't o3 — DUO E -Mail Address: t o124 'e 9 vv wic • Cyin GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: Sao\ COV 7V1ratti 0 Vl tscA N. 7-co G -t smote l ►'V1G WA- Contact Person: 1Y C V 011C E -Mail Address: tO1l c Q S jC CoV' . C 'NY) Contractor Registration Number: S A co** O`64'( ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City State Zip r., Day Telephone: 2 " 4.4 I - 1449 t E -Mail Address: t 9ol s{-€ - Q VYot1� rGtei tit •CTW1 Fax Number: 2 k -- 441 Contact Person: 1 Ac vvi 1n s-jiv v` fcco -t-es , wL 222- onn Aver v2 Sect - -- e. tts( Istc -tom Q\Applicalions\Forms- Applications On Line \3 -2006 - Permit Application. doc Revised. 9 -2006 66 Building Permit No. 9- 9 01S Mechanical Permit No. Plumbing/Gas Permit No. Public (For, office use only) King Co Assessor's Tax No.: City State Zip Day Telephone: 20b" tt 1t3 Fax Number: Expiration Date: ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Contact Person: Day Telephone: E -Mail Address: Fax Number: 2 5 -?mot 0 11c7 11 1012ot o wry qs 121 Company Name: , Mailing Address: City State Zip Page I of 6 S BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ It 4,, 000 Existing Building Valuation: $ Scope of Work f (please provide detailed information): 1 �-Y) �t 'IVY) O pans( 1121 00 Will there be new rack storage? ❑ Yes ❑.. No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square. Footage Below: : PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes.... No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers 'f., Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications \Forms - Applications On Line\3 -2006 - Permit Application.doc Re% ised 9 -2006 bh Page 2 of 6 Existing Interior Remodel Addition to; Existing Structure New Type :of_ . Construct u •. IBC per : Type of OeettiAitcy per ` c' IBC 1S Floor '�1(o 6 1 At 6 vklat tAta v-' loffice 2n Floor 3` Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport... Detached Carport Covered Deck .- Uncovered Deck S BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ It 4,, 000 Existing Building Valuation: $ Scope of Work f (please provide detailed information): 1 �-Y) �t 'IVY) O pans( 1121 00 Will there be new rack storage? ❑ Yes ❑.. No if yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square. Footage Below: : PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes.... No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers 'f., Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications \Forms - Applications On Line\3 -2006 - Permit Application.doc Re% ised 9 -2006 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits.: in this application Value of Construction -- In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall he requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING t " 1 ' • UT J' 1 i ► AGENT: Signature: Print Name: I Date Application Accepted: Date Application Expires: Staff Initials: (Ade • Date: 110-a f % V y Day Telephone: 1/012 6� - otOb$ Mailing Address: ��� f �' OVV P C; " (- W eS 1 t S� -- e o i t1\1 P\' 41 City State Zip Q:WpplicationslEorms- Applications On Line13 -2006 - Permit Application doc Revised: 9 -2006 bh Page 6 of 6 Receipt No.: R08 -03768 • City of Tukwila Payee: SOUTHCENTER CORP SQUARE ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Parcel No.: 2623049144 Permit Number: D08 -495 Address: 575 ANDOVER PK W TUKW Status: PENDING Suite No: Applied Date: 11/17/2008 Applicant: WASHINGTON STATE NURSES ASSOCIATION Issue Date: Initials: WER Payment Date: 11/17 /2008 10:10 AM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2193 506.93 Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Payment Amount: $506.93 304.50 197.93 4.50 Total: $506.93 • 9655 11/17 9707 TOTAL 506.93 doc: Receiot -06 Printed: 11 -17 -2008 Project: ,//)5 S - Mif ./14/ZCCS Type of Inspection: cmhl 7 Address: .-5 76 44/i / /-VB/ P ' cc.: Date Called: Special Instructions: Date Wanted: /...) era a.m L: uester: i Y Req Phone No: ,l 4Q o ` 7/8 -66 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Ap proved per applicable codes. ❑ Corrections required prior to approval. CO MENTS: l R cei No.: A PiVemaz INSPECTION RECORD Retain a copy with permit ii6 `S5 ci k--(e ,/n L PERMIT NO. (206)431 -3670 Date: $60 00 REINSPECTION E REQUIRED. rior to inspection, fee must be pai. at 6300 Southcenter lvd., Suite 100 Call to schedule reinspection. 'Date: qiL Project: 6/4h1 .5/4/ ,lkiisf5 Type of Ins ection: 5''6PC 7(/0/711/e Address: .5'75 /2N ( /i/ "/ A G D t o Called: Special Instructions: Date Wanted: / 6- 4 � p.m. Requester: Phone No // : / —6077 INSPECTION NO. INSPECTION RECORD b PERMIT NO. Retain a copy with permit g S CITY OF TUKWILA BUILDING DIVISION 4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval.? COMMENTS: L - NZ- A F Ins Date: # (_ Q ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: p Pr jec : VA) kl AO`k) Type of Inspection: A- il At 1 &U& NC) Address: 513 A NO a t' -1 Pv-tA Date Called: ) Special Instructions: / Date Wanted: (2 ( f! 6 1 (.6 ra- P.m. Requester: Phone No: '7 g INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 too a -ACS PERMIT NO. Y T (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: 1 2 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: C Project: j p p tA (rs'.5 Type of Inspection: CAD k.) e ' Fire Alarm: \ Address: c y r A e b.-I Suite #: At Contact Person: - 1 - 6 tf it 1 '... Special Instructions: N. • Phone No.: 0 5 95' S q b 7 • Needs Shift Inspettion: Sprinklers: . Fire Alarm: \ Hood & Duct: Monitor: 1 '... Pre-Fire: Permits: ... Occupancy Type: 1 INSPECTION NUMBER 444 Andover Park East, Tukwila Wa. 98188 206-575-4407 r Fg -Approved per applicable codes. COMMENTS: tot ,e9A. I f ' INSPECTION RECORD Retain a copy with permA CITY OF TUKWILA FIRE DEPARTMENT (1??- s- 3b - s PERMIT NUMBERS n Corrections required prior to approval. • Inspector: I V I Date: / 2 / (4 fa Hrs.: L • ,ti di $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from 'the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 Project: -- --' WA CT Nu ,t Ptt Aiur • Type of Inspection: /C Pig!! //ri/l/gi Sprinklers: Address: Al 69 5 Suite #: jo / ' OW Contact Person: ,.�� . h aa�c.rN - ,fir Special Instructions: Phone No.: • Y . 2qv- !W5 Permits: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: t. '/t �f `Occupancy Type: . 1 5sa'\ iv :1?1.tiF+s'.'�1+3.•fiwi�H�y.a. Y"v3Y:iw -: 2 INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 1/13/06 PERMIT NUMBERS CITY OF TUKWIILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 F7 Corrections required prior to approval. Inspector: 1 Date :. /// y/0 n $80 Q0►pEIiNSPECTION FEE REQUIRED. You will receive an invoice from the Citt i&Tukwila,, iniance Department. Call to schedule a reinspection. . L 1 • 'L .114., L ys e Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 COMMENTS: oz_ .SP,e,wr at h OR- IA' Abu- , off- I. ' ) rs.. (11/24/2008) Joanna Spencer - Re: Fwdly State Nurses Assoc @ 575 APW D0.5 Page 1 From: Han Kirkland To: Spencer, Joanna; Still, Bryan Date: 11/24/2008 1:16 PM Subject: Re: Fwd: WA State Nurses Assoc @ 575 APW D08 -495 Joanna, Per Bryan, backflows and meters are all up to date at this location. Thank you, Han »> Joanna Spencer 11/24/08 10:16 am »> Are they current on the backflows ? I forgot to put the address the first time, so it might be a duplication. Thanks, Joanna PERMANENT FILE COPY ACTIVITY NUMBER: D08 -495 DATE: 11 -17 -08 PROJECT NAME: WASHINGTON ST NURSES ASSOCIATION SITE ADDRESS: 575 ANDOVER PK W - SUITE 101 X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: I , � I,b � f u ding 'Dlvlsion Public Wor, t• Complete Comments: Please Route Documents/routing slip.doc 2-28-02 • PER ," IT COORD COPY PLAN REVIEW /ROUTING SLIP ry DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Fire Prevention TUES/THURS ROUTING: REVIEWER'S INITIALS: Incomplete Permit Center Use Only 'r �` • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required Response to Incomplete Letter # Revision # After Permit Issued 611 4114c, vikk. ► Planning Division Structural ❑ Permit Coordinator DUE DATE: 11 -18 -08 ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -16 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Not Applicable • Permit Center`Use • • • : • : • ''T ` ": • • • : ' . :t , CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Name Role Effective Date Expiration Date ABBOTT, JAMES W PRESIDENT 01/14/1991 Bond Amount MERISKO, BRIAN J VICE PRESIDENT 01/14/1991 52BSBC14979 SYLVESTER, JAMES R VICE PRESIDENT 11/27/2002 KOSNEY, SEAN N CHIEF EXECUTIVE OFFICER 01/10/2002 12/08/2004 LAYMAN, JOSEPH S TREASURER 01/14/1991 01/10/2002 MINNIEAR, GEORGE N VICE PRESIDENT 01/14/1991 01/10/2002 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 HARTFORED FIRE INS 52BSBC14979 01/10/2005 til Ca C ancelled $12,000.00 12/14/2004 4 FIRE INS CO HARTFORD SUN403819 01/10/2002 Until Cancelled 01/10/2005 $12,000.00 01/04/2002 3 HARTFORD FIRE INS CO SUN403819 01/10/199601/10 /2002 $6,000.00 2 FIREMANS FUND INS CO 11141449451 01/10/199201/10 /1996 $6,000.00 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£ti to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Business Owner Information Bond Information I SGA CORPORATION 2065332191 1501 N 200TH ST SHORELINE WA 98133 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601292201 ACTIVE SGACO * *084BS CONSTRUCTION CONTRACTOR 1/10/1992 1/10/2010 STEPHGA099BP GWINNMC007KJ GENERAL UNUSED https:// fortress .wa.gov /lni/bbip/Detail.aspx ?License = SGACO* *084BS • Page 1 of 3 11/26/2008 CS 0 C) 0 a) U) 0 CO 0 0 N z cn U) 0 0 U 0 U) U) a) 0 U) p -- Q 0 c) U) a) 0 0 M Q N I N cncn Cr) C.) cn 00 CD 0 0 N V) co 0_ > o II LL 0. .6 . 6 (13. 4 6' . E 0 CD STANDARD TENANT PARTITION PROVIDE 4' -0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING AT CORRIDOR PARTITIONS ACOUSTIC BATT INSULATION BETWEEN STUDS AT CORRIDOR PARTITIONS ACOUSTIC BATT INSULATION BETWEEN STUDS AT CORRIDOR PARTITIONS + 8' -3" A.F.F. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK PROVIDE ACOUSTIC BATT INSULATION BETWEEN STUDS AT CORRIDOR PARTITIONS IIIIf111111)1 SEISMIC BRACING PER 9 /TI -1 1/4" NON -COMB. WD FILLER UNDER MAIN RUNNERS CONTINUOUS CEILING GRID - DO NOT CUT. LINE OF CEILING GRID BEYOND, SEE REFLECTED CEILING PLAN CONT. 'L' METAL TRIM W/ PAPER WING CONT. 25 GA. TRACK W/ (2) #10 SCREWS @ 24" O.C. HEAD SECTION 5/8" GWB, TYPE 'X' EACH SIDE, TYP. BASE, AS SCHEDULED. CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN DIRECT FASTENING XZF2OTHP /35 COMBO FASTENER WITH 3/4" MIN. EMBEDMENT @ 24" O.C. OR SIMILAR. BASE SECTION 31/2 x 25 GA. GALV. STEEL STUD @ 24" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE. PLAN VIEW TENANT & CORRIDOR PARTITION iHr-c ALIGN EXISTING B/S CORRIDOR PARTITION NEW B/S CORRIDOR PARTITION. SEE DETAIL 8/TI -1. EXISTING B/S TENANT INTERIOR PARTITION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 7/TI -1, NEW WINDOW WITH SAFETY GLAZING AT 48" AFF. (WIDTH NOTED ON PLAN) NEW B/S INTERIOR DOOR 13 . CONSTRUCTION LEGEND SEISMIC BRACING DETAIL ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FN FLR FLUOR FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT JT ABBREVIATIONS SOUND PARTITIONS ONLY: 4' -0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE / HUNG CEILING - REVEAL (PAINT BLACK) 1/8" BLACK FOAM TAPE HOLD BACK 1/4" FROM EDGE OF TRACK SCHEDULED BASE 6" UNLESS OTHERWISE NOTED ACOUSTICAL CEILING TILE ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR / CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING, EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FIRE RATED FEET FURNISH I FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JOINT 12 DOOR SCHEDULE HARDWARE a. B/S LATCHSET. b. B/S LOCKSET W/ CLOSER. DOOR NUMBER TYPE OF DOOR A. NEW B/S 3' -0" WIDE x FULL HEIGHT S.C. WOOD DOOR IN B/S WOOD FRAME. LL @TE LF MAX MECH MFR MIN MISC MTD MTL MW N NA NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTN R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TBD TEL TYP UNO VCT W W/ W/O WC WD BY LANDLORD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE OVEN NORTH, NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS, REMOVE, RELOCATE RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION I REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TO BE DETERMINED TELEPHONE TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE WEST WITH WITHOUT WALLCOVERING WOOD 1/4" NON -COMB. WD FILLER UNDER MAIN RUNNERS HEAD SECTION SEISMIC BRACING PER DETAIL 9 /TI -1 CONTINUOUS CEILING GRID - DO NOT CUT LINE OF CEILING GRID BEYOND, SEE REFLECTED CEILING PLAN CONT. 'L' METAL TRIM W/ PAPER WING CONT. 3 5/8" x 1 1/4" 25 GA. TRACK W/ (2) #10 SCREWS @ 24" O.C. 3 5/8" x 25 GA. GALV. STEEL STUD @ 24" O.C. WITH 5/8" TYPE 'X' GWB EACH SIDE PLAN VIEW 5/8" GWB, TYPE 'X' EACH SIDE, TYP. CONT. 25 GA. GALV. STEEL RUNNER CHANNEL - ANCHOR TO FLOOR AS REQ'D. HILTI POWER DRIVEN FASTENER 3/4" MIN EMBEDMENT SCHEDULED BASE BASE SECTION EXISTING DOOR TO REMAIN NOTES: 1. PROVIDE W.S.B.F. COMPLIANT HARDWARE. 2. RE -USE EXISTING DOORS SCHEDULED FOR REMOVAL WHEREVER POSSIBLE. DOORS TO BE RE -USED ARE TO BE TOUCHED UP TO BRING INTO "LIKE NEW" CONDITION. 3. THRESHOLDS AT DOORWAYS SHALL BE 1/2" MAX. IN HEIGHT. 4. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MINIMUM AND 48" MAXIMUM ABOVE THE FINISH FLOOR. 5. FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. THE MAXIMUM FORCE FOR PUSHING OPEN OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: 1. INTERIOR HINGED DOOR: 5.0 POUNDS (22.2 N) 2. SLIDING OR FOLDING DOOR: 5.0 POUNDS (22.2 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. NOT A LEGAL SURVEY SITE PLAN VICINITY MAP BLDG 3 UPLAND D MIDLAND D TRILAND D MINK R ELVD. MINKLER BLVD. STRANDER BLVD. FIRE LIFE SAFETY NOTES: SINGLE TENANT TO OCCUPY ENTIRE FIRST FLOOR OF A TYPE V -N SPRINKLED BUILDING OCCUPANT LOAD & EXITING INFORMATION: 8,012 SF @ 1:100 = 80 OCCUPANTS 2 EXITS REQUIRED: 2 PROVIDED CONTINUOUS CEILING MSS ISM 111 ! 11111 , f 1 Akt ARUM MI ENS GRID - DO NOT CUT (2) #10 SCREWS LATERAL BRACING TENANT WALLS (NO CASEWORK) 8' MAX 8' MAX 8' MAX 8' MAX X X HVAC NOTES: 1. RECONFIGURE AS REQUIRED FOR ALTERATIONS. 2. REBALANCE HVAC SYSTEM. 3. CLEAN ALL EXISTING GRILLES. 4. VERIFY AND RELOCATE THERMOSTATS AS NECESSARY. LATERAL BRACING PER PART. PLAN DETAIL ABOVE (TYP.) NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT INTERSECTIONS WITH WALLS THAT ARE AT LEAST 4 FT. LONG. (PER TYP. PART. PLAN) 2. TEMPORARY ATTACHMENT OF PARTITION TOP TRACK TO THE CEILING GRID IS PERMITTED TO ALIGN AND SET THE WALL UNTIL PERMANENT BRACING IS IN PLACE. REMOVAL OF THE TEMPORARY HOLDING SCREWS IS AT THE DISCRETION OF THE SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO VERIFY. 3. LATERAL BRACING IS TO BE INSTALLED ON ANY TENANT PARTITION THAT IS NOT PERMANENTLY ATTACHED TO THE CEILING GRID. 1. ALL FIRE EXTINGUISHERS, HORN STROBES, EXIT SIGNS AND SPRINKLER HEADS, ETC. TO MEET REQUIREMENTS PER CURRENT CODE. 2. VERIFY FINAL LOCATION WITH INSPECTOR AND TENANT. 14 HVAC & FIRE LIFE SAFETY NOTES SUSPENDED CEILING METAL STUDS STAGGERED @ 8' -0" 0.C. FOR ALL UNERACED STRAIGHT RUNS OF WALL OVER 12' -0" - ATTACH TO STRUCTURE ABOVE W/ APPROPRIATE POWER DRIVEN FASTENERS KEY PLAN WITH OCCUPANCY LOAD CALCULATION INSTALLATION • NO CHANGE IN OCCUPANCY • NO CHANGE IN USE • NO INCREASE IN BUILDING AREA • NO CHANGE IN EXITING • NO CHANGE TO BUILDING CORE AND SHELL SUSPENDED CEILING SUPPORT DATA COMMON PATH OF TRAVEL = 33' -9" 118" DIAMETER x 3" CONCRETE EYE SCREW TO STRUCTURE VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4' -0" O.C. OR NO. 10 GAUGE @ 5' -0" O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE "PIN ". VERTICAL STRUT STABLING BAR @ 12' -0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. HEAVY DUTY MAIN RUNNER AT 4-0" O.C. (4) LATERAL SUPPORT WIRES AS NOTED (BELOW). VERTICAL STRUT FASTENED TO MAIN RUNNER. AREA OF WORK/ EXPANSION INSTALL PER INTERNATIONAL BUILDING CODE SECTION 803.9.1.1. AND 1621.1 "SUSPENDED ACOUSTICAL CEILINGS" AND ASCE 7 -02. LATERAL SUPPORT SHALL BE PROVIDED BY FOUR WIRES OF MIN. 12 U.S. GAUGE SPLAYED IN FOUR DIRECTIONS, 90 DEGREES APART AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORTS SHALL BE PLACED 12' -0" O.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' -0" FROM EACH WALL. PROVIDE LATERAL BRACING AT ALL CEILING AREAS GREATER THAN 144 S.F. SURROUNDED BY WALLS THAT CONNECT DIRECTLY TO STRUCTURE ABOVE. VERTICAL SUPPORTS SHALL BE NO. 8 U.S. GAUGE WIRE TO SUPPORT A MAX. 16 SQ. FT. OF CEILING AND SADDLE -TIED AROUND MAIN RUNNERS, PER 2003 IBC SECTION 803.9.1.1. CROSS RUNNERS ATTACHED TO MAIN RUNNERS BY SADDLE -TYING WITH ONE STRAND NO. 16 U.S. GAUGE TIE WIRE, OR APPROVED EQUIVALENT, PER 2003 IBC SECTION 803.9.1.1. DISCONTINUOUS ENDS OF CROSS- RUNNERS AND MAIN RUNNERS TO BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH DISCONTINUITIES AS MAY OCCUR WHERE CEILING IS INTERRUPTED BY A WALL. CEILINGS OVER 2,500 S.F. MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HT PTNS THAT BREAK THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 S.F. FOR CEILINGS W/O RIGID BRACING, SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS: OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMODATE 1" OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID AND UPGRADE TO DETAILS SHOWN. NOTES: 1. POWER DRIVEN FASTENERS SHALL NOT BE USED FOR TENSION LOAD APPLICATIONS. 2. THE GRID SHALL BE ATTACHED AT TWO ADJACENT WALLS. SUSPENDED CEILING SUPPORT DATA NTS 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, AND LOCAL BUILDING AND FIRE CODES AS REQUIRED. 2. CONTRACTOR SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN CONTRACT DRAWINGS AND SPECIFICATIONS FOR BUILDING. 3. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND NOTIFY MS&A OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK. 4. DIMENSIONS TO AND OF ELECTRICAL & TELEPHONE OUTLETS INDICATES MAXIMUM OF 6" FROM CENTERLINE OF ELECTRICAL OUTLET TO CENTERLINE OF TELEPHONE OUTLET. 5. CONTRACTOR TO OBTAIN ALL PERMITS AND APPROVALS, UNLESS NOTIFIED OTHERWISE. 6. WALLS AND CEILINGS TO BE INDEPENDENTLY SUPPORTED, FOR SEISMIC CONDITIONS, IN BUILDING JURISDICTIONS WHERE APPLICABLE. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INDICATED IN THE CONTRACT DRAWINGS & SPECIFICATIONS FOR THIS PROJECT. 8. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, FIRE ALARM &SECURITY SYSTEM RENOVATIONS SHALL BE PROVIDED UNDER SEPARATE PERMITS. 9. CONTRACTOR TO PROVIDE BLOCKING AT ALL WALL - MOUNTED ITEMS. 10. CONTRACTOR SHALL ALIGN OR FURR ALL INTERIOR PARTITIONS SO THAT FINISHES REMAIN FLUSH IN ROOMS AND CORRIDORS REGARDLESS OF DIFFERENCES IN PARTITION WIDTHS. 11. CONTRACTOR TO PROVIDE LEVELING THROUGHOUT THE SPACE FOR PROPER INSTALLATION OF EQUIPMENT, PARTITIONS, DOORS, GLUE -DOWN CARPET, ETC. TOLERANCE OF 1/4" IN 10' -0" DIFFERENCE IS ACCEPTABLE. GENERAL NOTES 1/16" =1' -0" SCOPE OF WORK: MINOR TENANT IMPROVEMENT TO AN EXISTING OFFICE SPACE ON THE FIRST FLOOR. BUILDING INFORMATION: SITE ADDRESS: 575 ANDOVER PARK WEST, TUKWILA, WA 98188 CONSTRUCTION TYPE: V -N, SPRINKLED AREA OF SUITE: AREA OF EXPANSION: OCCUPANCY: NUMBER OF STORIES: APPLICABLE CODES: LEGAL DESCRIPTION: TENANT: DESIGNER: • ''�'� i 4 CEILING NOTES: 8,012 USF ± 1,000 SF B- OFFICE ALL THAT CERTAIN REAL PROPERTY SITUATED IN THE CITY OF TUKWILA, COUNTY OF KING STATE OF WASHINGTON, BEING A PORTION OF THE EAST 1/2 OF THE NORTHWEST 1/4 OF THE SOUTHEAST 1/4 OF SEC. 26, T.23N, R.4E, W.M., AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE INTERSECTION OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4 WITH THE WESTERLY MARGIN OF ANDOVER PARK WEST (59TH AVENUE SOUTH), DISTANT ALONG SAID NORTHERLY LINE N88 ° 05'42 "W 1369.34 FEET FROM THE NORTHWEST CORNER OF SAID SOUTH- EAST QUARTER; THENCE FROM SAID POINT OF BEGINNING ALOND SAID WESTERLY MARGIN S01 °47'29 "W 451.30 FEET; THENCE LEAVING SAID WESTERLY MARGIN TANGENT TO THE PRECEDING COURSE ALONG THE ARC OF A CURVE TO THE RIGHT HAVING A RADIUS OF 50.00 FEET AND A CENTRAL ANGLE OF 90 °06'49 ", AN ARC LENGTH OF 78.64 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 501.40 SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID PARALLEL LINE N88 ° 05'42 "W 180.90 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH AND 261.00 FEET WESTERLY OF THE EAST LINE IF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 136.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 365.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE S88 °05'42 "E 37.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 223.50 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 100.00 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 265.40 FEET SOUTHERLY OF THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG LAST SAID PARALLEL LINE N88 °05'42 "W 12.50 FEET TO A POINT ON A LINE THAT IS PARALLEL TO AND 236.00 FEET WESTERLY OF THE EAST LINE OF SAID EAST 1/2; THENCE ALONG LAST SAID PARALLEL LINE N01 °47'29 "E 265.40 FEET TO A POINT ON THE NORTHERLY LINE OF SAID SOUTHEAST 1/4; THENCE ALONG SAID NORTHERLY LINE S88 °05'42 "E 206.00 FEET TO THE POINT OF BEGINNING AND CONTAINING 2.408 ACRES OF LAND MORE OR LESS. WASHINGTON STATE NURSES ASSOCIATION 575 ANDOVER PARK WEST SEATTLE, WA 98188 CONTACT: JUDY HUNTINGTON TEL: (206) 575 -7979 EMAIL: jhunting @wsna.org MARVIN STEIN & ASSOCIATES, LLC 2221 FIFTH AVENUE SEATTLE, WA 98121 CONTACT: LISA BOLSTER TEL: (206) 441 -1449 FAX: (206) 441 -4361 EMAIL: (.bolster @marvinstein.com TI -1 COVER SHEET & DETAILS 16 SHEET INDEX INTERNATIONAL BUILDING CODE, 2006 EDITION INTERNATIONAL FIRE CODE, 2006 EDITION WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 -11 WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY CODE (WSVIAQ) BUILDING REPRESENTATIVE: AMERICAN MANAGEMENT SERVICES DBA PINNACLE SEATTLE, WA 98104 CONTACT: TAMARA GENZALE TEL: (206) 903 -0662 FAX: (206) 903 -0668 EMAIL: tgenzale @prmc.com CONTRACTOR: EXISTING GWB CEILING TO REMAIN T.B.D. (TO BE DETERMINED) PROJECT INFORMATION EXISTING CEILING GRID AND TILES TO REMAIN 11 CEILING LEGEND & NOTES Kt .Vit.VVCU t UR CODE COMPLIANCE APPROVED NOV 2 5 008 EXISTING B/S 2x4 RECESSED FLUORESCENT FIXTURE EXISTING B/S 2x4 RECESSED FLUORESCENT FIXTURE TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL. EXISTING 8/S DOWNLIGHT TO BE REMOVED IEA B/S LIGHT SWITCH • EXISTING B/S ILLUMINATED EXIT SIGN. (DIRECTIONAL WHERE SHOWN) 'N' NEW Of Tukwila UILDIN DIVI ION EXISTING GWB CEILING TO BE REMOVED AND REPLACED WITH NEW GRID AND TILES TO MATCH SURROUNDING EXISTING CEILING GRID AND TILES TO BE REMOVED AND REPLACED WITH NEW GWB CEILING TO MATCH SURROUNDING 1. PRIOR TO INSTALLING ANY LIGHT FIXTURES ON THIS PROJECT, THE ELECTRICAL CONTRACTOR IS TO FIELD CHECK FOR ANY CONFLICTS WITH EXISTING MECHANICAL DUCT WORK, ELECTRICAL CONDUIT, PIPES, ETC. AT EVERY LIGHT FIXTURE LOCATION AS SHOWN ON THE REFLECTED CEILING PLAN. IF A CONFLICT EXISTS, THE ELECTRICAL CONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR IS TO NOTIFY MS &A OF THE CONFLICT(S) SO A NEW LAYOUT CAN BE GENERATED. NO LIGHT FIXTURES ARE TO BE INSTALLED UNTIL ALL CONFLICTS ARE RESOLVED. 2. CONTRACTOR SHALL DESIGN & PROVIDE EMERGENCY PATHWAY LIGHTING PER CODE. DESIGN PROVIDED IN THESE DRAWINGS IS CONCEPTUAL ONLY. 3. CONTRACTOR SHALL VERIFY LATERAL BRACING AT EXISTING CEILING GRID & UPGRADE TO CURRENT CODES AS NECESSARY. 4. CONTRACTOR TO UPGRADE AUDIBLE AND VISUAL ALARMS TO CURRENT CODES AS NECESSARY. 5. THERE SHALL BE 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF V.A.V. BOXES. IF LIGHTING LAYOUT CREATES A CONFLICT, NOTIFY MS&A PRIOR TO ANY INSTALLATION. THIS IS TO INSURE NO FIELD REVISIONS WILL BE REQUIRED. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING ANY DAMAGED CEILING TILES AND GRID OR EXTENDING ACT CEILING OR GWB CEILING AS NECESSARY TO MATCH EXISTING AS REQUIRED. 7. DAYLIGHT ZONE CONTROL: ALL DAY LIGHTED AS DEFINED IN CHAPTER 12, BOTH UNDER OVERHEAD GLAZING AND ADJACENT TO VERTICAL GLAZING, SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, WHICH CONTROLS THE LIGHTS INDEPENDENT OF THE GENERAL LIGHTING AREA PER 1513.3 OF THE WASHINGTON STATE ENERGY CODE. 8. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF FIRE SPRINKLERS DESIGN AND CONSTRUCTION. IN THE EVENT OF A CONFLICT REGARDING NEW LIGHTS, WALLS, SOFFITS, AND OTHER FIXTURES, THE SPRINKLER HEADS MUST BE MOVED. 9. COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUTOFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TES PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS NOTE. SWEEP CONTROLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. TI -2 DEMOLITION, CONSTRUCTION & REFLECTED CEILING PLANS SOUTHCENTER CORPORATE SQUARE 575 ANDOVER PARK WEST TUKWILA, WA 98188 Pier review approval Is subject to errors and cn`ssfon . Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is ackilo w1cs gcd: By Date: REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j SEPARATE PERMIT REQUIRED FOR: (Mechanical (Electrical [eIumbing Vas Piping City of Tukwila E UII,.DING DIVISION Marvin Ste planning DRAWN BY: MW CHECKED BY: LB REVISIONS /ISSUANCE: H 2( 0 City or Tukwila E LDiNe Di : iSION NO. REVISIONS INDICATED THUS A TENANT: SHEET TITLE: REGISTERED A IH%7f FT GL` -O: GE H. r • ►, LLOW III REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. sociates, LLC design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 JOB NO.: 99135.062 DATE: 11 /12/08 PERMIT SET SCALE: AS NOTED DATE WASHINGTON STATE NURSES ASSOCIATION BUILDING 3 - FIRST FLOOR COVER SHEET & DETAILS RECEsvF ' NOV 1 7 2003 PEHMIT GEN TL J U J d W El C) C 0 0 co 0 0 N (f) C 0 • 0 U 0 co co U) 0 C) C 0 Cl Cr C 0 0 c.2 L V 0 ® C9) DEMOLITION PLAN 1/8" =1' -0" 5' 10' 20' 30' L DEMOLITION NOTES: 1. A CLEAR PATH SHALL REMAIN OPEN AT ALL TIMES DURING TENANT IMPROVEMENT. 2. DISRUPTION OF BUILDING WATER, ELECTRICAL POWER, FIRE ALARM & SECURITY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & BUILDING OWNER/MANAGEMENT. NORTH DEMOLITION KEY NOTES: 0 RELOCATE DOORS TO NEW ENTRY DOOR LOCATION. SEE 2/TI -2. 0 RELOCATE DOOR TO NEW OFFICE #106. SEE 2/TI -2. O REMOVE CORRIDOR RELITE AND PLACE IN PROPERTY MANAGEMENT STORAGE. 0 RELOCATE RELITE TO NEW OFFICE #102. SEE 2/TI -2. OFFICE 0 CONSTRUCTION PLAN 1/8" = 1'-0" 5' 10' EXISTING SUITE 20' CONSTRUCTION NOTES: 6 n MIN. DIM. 1. PATCH AND REPAIR FLOORING AS NECESSARY TO MATCH ADJACENT CONSTRUCTION. CONFERENCE (EXISTING) 101 RECEPTION 30' 103 1 NORTH i I OH EXPANSION OFFICE (EXISTING) OFFICE (EXISTING) OFFICE MINN - I - - I 11■,• CONSTRUCTION KEY NOTES: 0 ALIGN NEW WALL AT CORNER OF EXISTING WALL 0 DOOR RELOCATED FROM EXISTING OFFICE. SEE 1/TI -2. O RELOCATED ENTRY FROM EXISTING ENTRY. SEE 1/TI -2. 0 RELITE RELOCATED FROM EXISTING OFFICE. SEE 1/TI -2. 0 1/8" =1' -0" 5' 10' CEILING NOTES: EXISTING SUITE 20' 30' 1. ALL EXISTING 2'x4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. THERE IS NO CHANGE IN WATTAGE. REFLECTED CEILING PLAN NORTH TH i I EXPANSION 103 W I NN L ! 1 __ I III■ MUNIEEMEIEM sAVII CEILING KEY NOTES: 0 EXISTING GWB CEILING TO REMAIN. MENEM 1111=1 104 105 106 KcyiL:WtU FOR CODE COMPLIANCE APPROVED EXISTING GWB CEILING TO BE REMOVED AND REPLACED 0 WITH NEW CEILING GRID AND TILES TO MATCH SURROUNDING. NOV 2 5 2008 City Of Tukwila 8 : I�DI NNNNN m DIVIC N RECEIVED NOV 17 20 PEHIMIT CENTEP NO. SOUTHCENTER CORPORATE SQUARE DRAWN BY: 575 ANDOVER PARK WEST TUKWILA, WA 98188 Marvin Ste planning CHECKED BY: LB REVISIONS /ISSUANCE: 2 REVISIONS INDICATED THUS A TENANT: SHEET TITLE: EGISTF; -iE ARCI 5EOR(IE H. Gtr ,/ FELL STATE OF W ASHING EC f sociates, LLc design 2221 Fifth Avenue, Seattle, Washington 98121 (206) 441 -1449 MW JOB NO.: 99135.062 REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MS &A, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MS &A 2008. DATE: 11/12/08 PERMIT SET SCALE: AS NOTED DATE WASHINGTON STATE NURSES ASSOCIATION BUILDING 3 - FIRST FLOOR DEMOLITION, CONSTRUCTION & REFLECTED CEILING PLANS TI -2 OF 2