Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-503 - WESTFIELD SOUTHCENTER MALL - WETZEL'S PRETZELS - KIOSK
WETZEL' S PRETZELS 2800 SOUTHCENTER MALL K-9240 D08-503 Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Tenant: Name: WETZEL'S PRETZELS Address: 2800 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Phone: Contact Person: Name: TED ROLLOLAZO Address: 624 SW 293 ST , FEDERAL WAY WA 98023 Phone: 253 320 -1894 Contractor: Name: ENDURABUILT INC Address: 851 SE SOMERS DR , SHELTON WA 98584 Phone: 360 - 427 -1581 Contractor License No: ENDURI *930BH CitAf Tukwila • DESCRIPTION OF WORK: INSTALL KIOSK (PLUMBING AND ELECTRICAL WORK TO BE UNDER SEPARATE PERMIT) Value of Construction: Type of Fire Protection: Type of Construction: doc: IBC -10/06 $2,500.00 DEVELOPMENT PERMIT * *continued on next page ** Permit Number: D08 -503 Issue Date: 12/23/2008 Permit Expires On: 06/21/2009 Expiration Date: 01/08/2011 Fees Collected: $180.23 International Building Code Edition: 2006 Occupancy per IBC: 0019 D08 -503 Printed: 12 -23 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Signature: doc: IBC -10/06 City of/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N L i t ,..0 Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: Water Main Extension: Private: Public: Water Meter: N Permit Number: D08 - 503 Issue Date: 12/23/2008 Permit Expires On: 06/21/2009 End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Permit Center Authorized Signature: L -k.Q1 Date: 1)--?-3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of s p: t doe not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction • the - rfo of work. I am authorized to sign and obtain this development pe 't. Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -503 Printed: 12 -23 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: WETZEL'S PRETZELS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 2800 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: D08 -503 ISSUED 11/25/2008 12/23/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1)(Post address on kiosk per approved Westfield standards.) 13: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 D08 -503 Printed: 12 -23 -2008 doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us * *continued on next page ** • D08 -503 Printed: 12 -23 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 D08 -503 Date: ordinances governing or local laws regulating Printed: 12 -23 -2008 SITE LOCATION. King Co Assessor's Tax No.: 4' L il�t�' - 77) i, � S- c M ,t \ Tenant Name: I ' S i -x, 2e- IS Property Owners Name: 7 /e l /C7/c Z v Mailing Address: Cl `i 5 a- . 213 c - ra-j & 14.4 9,1) 23 State Zip Site Address: Name: Company Name: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: Mailing Address: Contact Person: E -Mail Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIL1 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** R vll® Q:\Applications\Porms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Suite Number: ¥— 1,2J 'U Floor: /1114 City New Tenant: ©.... Yes ❑ ..No z-•[.) Day Telephone: 3 3 - Mailing Address: 2- 2.13 ` 5t (ei &/a/ &may a(} fee 23 / City / State Zip E -Mail Address: ///e/ T o G / ae i°1G . s f • ' I ' c ' 7 Fax Number: ( 2 5 3 ) A( P5 3 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5 Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCLIIT] 11 Mans mist be wet: stamped by. Archlte t S f ( r 310 tAAltlbl roeiel I jk Ix 7c1I W W C t I City State Zip Day Telephone: Fax Number: City Day Telephone: Fax Number: (411- (0 1 u ' e we "t sta ped by Engineer r of e State Zip Page 1 of 6 tUILDING PERMIT Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): ON - .206 -431 -3670 Existing Building Valuatipn: $ v�� — �cl��t ilA�,6rl~ P Will there be new rack storage? ❑.... Yes MX If yes, a separate permit and plan submittal will be required. e All Building Areas in Square Footage Belo S t TA Fl Acces :ruc Attache Detached- .Gara; po A C Detached Car Covered '. eck Unl overed D ck /60 Type of Occupancy per II3C PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 PERMIT AP LI( 'ATIOIV NtTE. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extensioh shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AUTHORIZED GENT: Signature: Print Name: 7.-er) Mailing Address: 62. ci $Z) 29 Date Application Expires: Date Application Accepted: Q:\Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Applicable to a thi appli Date: /0 — 5W / Day Telephone: gS- >3Z-G7'7'cP91 zz a7 City State Zip Staff Initials: Page 6 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath /shower Drinking fountain or w. cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder commercial Receptor, indirect aste Clothes washer, domestic Floor drain , ks Dental unit, cuspidor Shower, si a head trap Ur . Is Dishwasher, domestic, with independent drain Lavatory ; Wat Closet Building sewer or trailer park sewer Rai ater system — per d ; ' (inside building) Water h ; er and/or vent Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors epair or alteration of water piping and /or water treating equipment Repair or alteation of drainage or t piping Medical gas piping system serving one to five inlets /outlets for specific gas MBING AND GAS PIPIN( ERMIT INFORMATR) PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: State cit Contact ' erson: Day Telephone: E -Mail A • ess: Fax Number: Contractor R stration Number: Expiration Date: Valuation of Plumbing ork (contractor's bid price): $ Valuation of Gas Piping k (contractor's bid price): $ Scope of Work (please provi •'4 • etailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping out Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Sewer: g installed and the quantity below: Page 5 of 6 Receipt No.: R08 -03827 Initials: JEM User ID: 1165 Payee: TED L ROLLOLAZO City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Permit Number: D08 -503 Address: 2800 SOUTHCENTER MALL TUI{W Status: PENDING Suite No: Applied Date: 11/25/2008 Applicant: WETZEL'S PRETZELS Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8012 180.23 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT Total: $180.23 Payment Amount: $180.23 Payment Date: 11/25/2008 03:34 PM Balance: $0.00 106.50 69.23 4.50 9930 11/25 9707 TOTAL 180.23 doc: Receipt-06 Printed: 11 -25 -2008 Project: -tic T7_, S' 2 Type of Inspection: / No Address: • Bad / '77 4 / Date Called: Special Instructions: Date Wantedt:/ �+ Y— 7— Q`-7 p.m Requester: Phone No: 3C4 - 1 -/z 3 beg-se 5 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Date: 60.00 REINSPECTI01( FEE R9 UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: (xL ❑ Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: hiAz,,J(- 4M /AJS P e",1,14-ovi.04/4tysR;a 1 / 4=-'71.4.4/ d7e- Project: _ n) T e of Ins ection :' Are Alarm: Address: .„ )23,et, S.0 . Suite #: A- a !o )8 I- Contact Person: CvA; i Hood & Duct: et.) Monitor: Special _Instructions, rYet 1.- Phone No.. 3 4 : 5 b - - > S' -3 .Needs Shift Inspection: n) Sprinklers: 'P.5 Are Alarm: /`') WI- t- Hood & Duct: et.) Monitor: rYet 1.- Pre -Fire: Permits: iN . 4 Occupancy Type: i INSPECTION NUMBER 4 pproved. per applicable codes. INSPECT/ION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT . Word /Inspection Record Form.Doc 1/13/06 '. -So.? . PERMIT NUMBERS 444 Andover Park East TukwilaWa. 98188 206 -575 -4407 Corrections required prior to approval. COMMENTS: evr, ,(L A' e clk l Inspector: ? e Date: 3 -/.// 0 7 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P 113 I December 3, 2008 Ted Rollolazo 624 SW 293 St Federal Way, WA 98023 Dear Mr. Rollolazo, R)AQ'4amdn- Bill Rambo Permit Technician Enclosures File: D08 -503 • City of Tukwila RE: Letter of Incomplete Application # 1 Development Permit Application D08 -503 Wetzel's Pretzels — 2800 Southcenter Mall, #K -9240 • Department of Community Development This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 25, 2008, is determined to be incomplete. Before your application can continue the plan review process the following items from the following department need to be addressed: Building Department: Allen Johannessen at 206 -433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted throuMh the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, P:\Permit Center\Incomplete Letters\2008\D08 -503 Incomplete Ltr #1.DOC wer Jim Haggerton, Mayor Jack Pace, Director 6. ?00 .Snuthrenter Rnn1P.vard..Svita. #100 o Tukwila_ Wa.shinutnn 08188 • Phnnp: 2015- 4.31 -. ?h70 • Fauf 206- 411 - ?hhS • Determination of Completeness Memo Date: December 2, 2008 Project Name: Wetzel's Pretzels Permit #: D08 -503 Plan Review: Allen Johannessen, Plans Examiner 3. Specify safety glazing where glazing is shown in the kiosk. Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a clear floor plan of the mall corridor where the Kiosk shall be placed. Provide dimensions to clearly show minimum horizontal separation between kiosks or groupings thereof and other structures within this vicinity of the mall that shows the kiosk has a minimum 20 foot clearance between kiosks and structures or 10 feet clearance on each side of this kiosk. (IBC 402.10) 2. Plans shall identify type of materials used for the kiosk i.e. fire retardant treated wood complying with IBC Section 2303.2, foam plastics having maximum heat release rate not greater than 100kW (105 Btu/hr) when tested in accordance with the exhibit booth protocol in UL 1975 and Aluminum Composite Materials (ACM) having flame spread index not more than 25 and smoke - developed index not more than 450 per ASTM E84. Please specify type of materials used for this kiosk in compliance code requirements indicated above. (IBC 402.10) Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 - 3670. No further comments at this time. DEPARTMENTS: Q, Build g Division Complete Comments: TUES/THURS R UTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 • • ER If PLAN REVIEW /ROUTING SLIP t' ACTIVITY NUMBER: D08 -503 DATE: 12 -10 -08 PROJECT NAME: WETZEL'S PRETZELS SITE ADDRESS: 2800 SOUTHCENTER MALL - K9240 Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention Public Works ( Structural Q Z, DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Structural Review Required n Planning Division n Permit Coordinator DUE DATE: 12-11 -08 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required DATE: DUE DATE: 01 -08 -09 Not Approved (attach comments) n DATE: Not Applicable u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D08 - 503 PROJECT NAME: WETZEL'S PRETZELS SITE ADDRESS: 2800 SOUTHCENTER MALL, K -9240 X Original Plan Submittal Response to Correction Letter # DATE: 11 -25 -08 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: � �� 2'06 n Q Ivl I n Buil Public Works � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete L J Comments: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 �I ( ,0Jtci 1 Fire Prevention Incomplete j- It& It -2 -of) Plar'ining Division ❑ Permit Coordinator TUES/THURS ROUTING: Please Route n Structural Review Required ❑ No further Review Required ❑ DATE: DATE: DUE DATE: 12-02-08 Not Applicable ❑ • Permit Center Use Only • - • . INCOMPLETE LETTER MAILED: � Z"' O LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg lir Fire ❑ Ping ❑ PW ❑ Staff Initials: tkik APPROVALS OR CORRECTIONS: DUE DATE: 12-30-08 Approved n Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: 12/84/2888 18:52 2539419583 City of Tukwila Department of Commtud y Development 6300 Sonthcceiter Boulevard,: Suite #t00 Tukwila, Washington 981X$ Phone: 206-431-3670 Fax: 206-431-3665 Web site: / sage: /hvirmot.iukwila.wv,us Revision submittals mast be submitted is person at the Permits Curter. Revisions 1411 not he accepted through the ema4 forty etc. Date: Plan Check/PermitNnmber: 1)08 -503 • Response to Incomplete Letter # I ❑ Response to Caiiectian Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans *owner Project Name: WETZEL'S S PRETZELS Project Address: 2 00 SOUTHCENTER MALL -- K-9240 Contact Person: l ACV c Phone Number :( � 22-g Summary of Revision: Ap. I - Ae. nr v . n R,r,�n stk a r+at, . e . 44 le h Inc 1� 41.1 - 4414e4 e.� owe ID1�l.A .3 1 +./15 4�.s..r # br4 . ct /7 1 i I( Ott e4 te .7M"I we. �i. 1 � Z� AoLt aerie 4-o SIree.1 k j_ I (rnett.x 1 3' 4e(o1cJ io4e. Jo 5jeteL 1e1.! (►�ee+c Sheet Number(s): AO. I , A t I "Cloud" or highlight all areas of revision ineludhq Received at the City of Tukwila Permit Center by: 'Q- in Permits Plus on l 1 applicaltiooslforrr >e-evpReations on iinolra ieiiou submittal Created: 8- 134004 Rased: • • RDLLOLAZO LEE INC PAGE 84 Steven M Muller. Mayor Steve Lancaster. Director C Tu>= I DEC 10 2003 7 cairgh Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 I Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 ' ? , (✓ Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 teil King County Department of Natural Resources and Parks Wastewater Treatment Division • Non - Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type kAlVailk "WA- on City State ZIP Owner's Alife//d 2 jfe / /o/aza a;fr/ fie - r Subdivision Name Subdiv. # Building Name (if applicable) ( ) Please report any demolitions of pre - existing building on this property. Owner's Phone Number (with Area Code) Credit for a demolition may be given under some circumstances. Demolition of pre- existing building? ❑ Yes [I1No ( ) Was building on Sanitary Sewer? i' 'es ❑ No Property Contact Phone Number (with Area Code) Owner's Mailing Address Was Sewer connected before 2/1/90? O Yes Ell o Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? ❑ Yes ❑ No A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units _ 20 Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206 - 684 -1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of correct t. f• , . - - ination of a revised capacity charge. Signature of Owner /Representa Date i 2-- Print Name of Owner /Representative 1058 (Rev. 9/07) Total Fixture Units 2, S � RCE Lot # Block # For King County ',Only Account # No. of RCEs Monthly Rate Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility /Process: Estimated Wastewater Discharge: Gallons /days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal /day) _ 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE White - Kin() County Yellow - Local Sewer Acency Pink - Sewer Customer RCE Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 OHIO CAS INS CO BH00953052113 06/08/2008 06/08/2009 01 /08/2007 $1,000,000.0006 /02/2008 1 OHIO CAS INS CO BH00753052413 06/08/200606/08 /2008 $1,000,000.0005 /25/2007 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG1707 12/14/2006 Until Cancelled 01 /08/2007 $12,000.00 01/08/2007 Name Role Effective Date Expiration Date LAWSON, CRAIG PRESIDENT 01/08/2007 LAWSON, MARCIA SECRETARY 01 /08/2007 LAWSON, MARCIA VICE PRESIDENT 01 /08/2007 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ENDURABUILT INC 3604271581 851 SE SOMERS DR SHELTON WA 98584 MASON CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License ENDUR * *964CQ Next License Associated License Specialty 1 GENERAL Specialty 2 UNUSED 602673124 ACTIVE ENDURI *930BH CONSTRUCTION CONTRACTOR 1/8/2007 1/8/2011 Business Owner Information Bond Information Insurance Information • • Page 1 of 1 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= ENDURI* 930BH 12/23/2008 0 EXISTING L = LANDLORD DESCRIPTION 0 = OWNER 0 NEW C = CONTRACTOR FURNISH BY INSTALL BY GENERAL L o C L o C BUILDING PERMIT BY TENANT (PICKED UP AND PAID FOR BY T.G.C.) • PLAN CHECK FEES ALL OTHER PERMITS • INSPECTIONS AND INSURANCE • TEMPORARY POWER • • BARRICADE, IF REQUIRED • • CLEAN UP • CONCRETE SLAB 0 0 CONCRETE SLAB WORK —SAW CUT SLAB & CORE DRILLING • • KIOSK • • • KITCHEN EQUIPMENT (REFER TO KITCHEN EQUIPMENT SCHEDULE) e • MALL FLOORING ® KIOSK AS REQUIRED 0 • 0 • ILLUMINATED KIOSK SIGN GENERAL CONTRACTOR TO COORDINATE INSTALLATION WITH VENDOR • 411 KIOSK ANCHORAGE TO FLOOR • • KIOSK INTERIOR /EXTERIOR TILE BASE • • PREZEL MOSAIC ON EXTERIOR OF KIOSK FACE(S) • • I PROJECT TEAM WETZELS PRETZELS FRANCHISEE ARCHITECT: LANDLORD: PROJECT MANAGER: PROJECT ADDRESS: TENANT OCCUPANCY: NUMBER OF STORIES: APPLICABLE CODES: PROPOSED USE: KIOSK LEASE AREA: NUMBER OF EMPLOYEES (AT ONE TIME): EGRESS REQUIREMENTS: TOILETS REQUIRED: I BUILDING INFORMATION CHAT CHAO 10821 RAINIER AVENUE SOUTH SEATTLE, WA 98178 TEL: (206) 228 -1498 MICHAEL R. BLACK 3100 E. RANDOL MILL RD. ARLINGTON, TX TEL: (817) 701 -4819 FAX: (817) 633 -4153 WESTFIELD, LLC 11601 WILSHIRE BLVD., 14TH FLOOR LOS ANGELES, CA 90025 ATTN: SUZANNE ESCABAR PHONE: (310) 689 -5643 LAURIE KEYS 11 WELLINGTON PLACE ALISO VI CA 92656 PHONE FAX (949) 2161 SOUTHCENTER MALL 633 SOUTHCENTER KIOSK SPACE #9240 SEATTLE, WA 98188 M, MERCANTILE LEVEL 2 OF 2 FOOD RETAIL 180 SQUARE FEET 3 MAX. 1 REQUIRED, 1 PROVIDED PUBUC RESTROOMS PROVIDED BY LANDLORD ABBREVIATIONS ABV ADJ AFF ACT A/C ALT ARCH BLKG BD BLDG CLR CLG CONC COL CMU CONST DTL DIAM DIM DR DWG DISP (E), EX EA EL, ELEV ELECT EQ EXT FES FF Fr FLR FLUOR FOF FOS FIN FRP FO GA GC GL GYP HORIZ INT INSUL MAX MECH MIN (� NIC NTS 0/ O.C. O.S.C.I. PSI PLAM PLYWD R.C.P. SHT SIM SQ SS TBD TYP UBC UON UTR V1F WH BUILDING: 2006 INTERNATIONAL BUILDING CODE MECHANICAL: 2006 INTERNATIONAL MECHANICAL CODE PLUMBING: 2006 INTERNATIONAL PLUMBING CODE ELECTRICAL: 2005 NATIONAL ELECTRICAL CODE FIRE: 2006 INTERNATIONAL FIRE CODE ENERGY: 2006 WA STATE ENERGY CODE ABOVE ADJACENT ABOVE FINISHED FLOOR ACOUSTICAL CEIUNG TILE AIR CONDITIONING ALTERNATE ARCHITECTURAL) BLOCKING BOARD BUILDING CLEAR CEIUNG CONCRETE COLUMN CONCRETE MASONRY UNIT CONSTRUCTION DETAIL DIAMETER DIMENSION DOOR DRAWING DISPENSER EXISTING EACH ELEVATION ELECTRICAL EQUAL EXTERIOR FIXTURE EQUIPMENT SUPPLIER FINISHED FLOOR FEET FLOOR FLUORESCENT FACE OF FINISH FACE OF STUD FINISH(ED) FIBERGLASS REINFORCED PANEL FACE OF GAUGE GENERAL CONTRACTOR GLAZING, GLASS GYPSUM HORIZONTAL INTERIOR INSULATION MAXIMUM MECHANICAL MINIMUM METAL NEW NOT IN CONTRACT NOT TO SCALE OVER ON CENTER OWNER SUPPLIED/ CONTRACTOR INSTALLED POUNDS PER SQUARE INCH PLASTIC LAMINATE PLYWOOD REFLECTED CEIUNG PLAN SHEET SIMILAR SQUARE STAINLESS STEEL TO BE DETERMINED TYPICAL UNIFORM BUILDING CODE UNLESS OTHERWISE NOTED UP THROUGH ROOF VERIFY IN FIELD WATER HEATER I KEY PLAN FRESH PRETZELS LEMONADE HOT DOGS VENDOR LIST KIOSK: SOUTHCENTER MALL SEATTLE, WA EQUIPMENT: I SCOPE THE CARRIAGE WORKS, INC. 1877 MALLARD LANE KLAMATH FALLS, OR 97601 ATTN: DAN DAWSON PHONE: (541) 882 -0700 EDWARD DON & CO. 2500 S. HARLEM AVE. N. RIVERSIDE, IL 60546 ATTN: STEVE WISHON PHONE (800) 677 -4366 EXT. 8526 INSTALLATION OF U.L. AND N.S.F. LISTED KIOSK. UTILITIES TO KIOSK BY LANDLORD. FINAL CONNECTIONS BY G.C. G.C. SHALL PATCH /REPAIR MALL FLOORING AT NEW PLUMBING /ELECTRICAL WORK. ALL MATERIALS NOT PART OF PREFABRICATED KIOSK, SUPPLIED /INSTALLED BY G.C. G.C. SHALL TURN —OVER FULLY OPERATIONAL KIOSK. RECEIPT OF OWNER PROVIDED ITEMS NOTE: ITEMS PROVIDED BY TENANT: THE TENANTS GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIPT AND SUBSEQUENT PROTECTION OF ALL ITEMS WHICH ARE FURNISHED BY TENANT AND ARE TO BE INSTALLED BY TENANT'S GENERAL CONTRACTOR. ITEMS PROVIDED BY TENANT WILL BE INDICATED ON THE EQUIPMENT RESPONSIBILITY SCHEDULE SHEET AND THE MECHANICAL AND ELECTRICAL SCHEDULE SHEET. IN AN EFFORT TO BETTER ASSIST YOU IN THE EVENT OF POSSIBLE FREIGHT DAMAGE, WE ARE REQUESTING THAT YOU DO THE FOLLOWING PRIOR TO SIGNING THE CARRIER'S PROOF OF DEUVERY. WITHOUT ANY NOTATION OF DAMAGES ON THIS DOCUMENT, WE CANNOT PURSUE THE CARRIER FOR REPLACEMENT AND /OR REPAIR COSTS FOR THE ITEM(S). IN THE EVENT THAT DAMAGES ARE NOT NOTED, EDWARD DON & COMPANY WILL NOT BE HELD LIABLE FOR THESE ASSOCIATED COSTS. • INSPECT, THOROUGHLY, THE OUTER PACKAGING OF THE FOOD SERVICE EQUIPMENT PRIOR TO SIGNING THE CARRIER'S PROOF OF DEUVERY. • IF THERE IS VISIBLE DAMAGE TO THE PACKAGING, NOTE THE EXCEPTION, IN DETAIL, THE DAMAGE WHICH SHOULD INCLUDE THE MAKE, MODEL, AND QUANITY. THERE SHOULD NEVER BE STATEMENTS WRITTEN SUCH AS "JUST A SCRATCH, OR DAMAGED BOX ". STATEMENTS LIKE THESE GIVES THE CARRIER JUSTIFICATION FOR DENYING CLAIMS IF WE HAVE TO REPLACE OR REPAIR THE DAMAGED ITEM. • IF THE SHIPMENT IS LABELED AS "FRAGILE ", YOU HAVE THE RIGHT TO OPEN AND INSPECT THE CONTENTS BEFORE SIGNING THE CARRIER'S PROOF OF DEUVERY. THIS SHOULD ALWAYS BE THE CASE WHEN YOU ARE RECEIVING DISPLAY GLASS CASES. • APPARENT EXTREME DAMAGES TO FREIGHT SHOULD ALWAYS BE REFUSED. IF FREIGHT IS REFUSED, EDWARD DON & COMPANY SHOULD BE NOTIFIED IMMEDIATELY SO THAT WE CAN ENSURE THAT A REPLACEMENT IS SHIPPED. • DAMAGES TO TRUE SHIPMENTS SHOULD ALWAYS BE REFUSED. NOTIFY EDWARD DON Sc COMPANY AND A REPLACEMENT WILL BE SHIPPED. • IT IS IMPERATIVE THAT ALL FREIGHT BE OPENED WITHIN 15 DAYS OF DEUVERY. THIS IS THE CUT —OFF POINT FOR RUNG FREIGHT CLAIMS IN THE EVENT OF A CONCEALED DAMAGE ISSUE. AFTER THIS 15 DAY TIME PERIOD HAS LAPSED, WE HAVE NO RECOURSE IN FILING A FREIGHT CLAIM AGAINST THE CARRIER. EDWARD DON & COMPANY WILL NOT BE HELD LIABLE IN THE EVENT THAT WE ARE NOT NOTIFIED OF CONCEALED DAMAGES WITHIN 15 DAYS OF THE DEUVERY. \ Wafters PretzeLs FRESH PRETZELS LEMONADE HOT DOGS KIOSK SPACE #9240 VICINITY MAP I DRAWING INDEX ARCHITECTURAL A0.1 RESPONSIBILITIES, INDEX, AND BLDG. INFO A0.2 SPECIFICATIONS A0.3 SPECIFICATIONS A1.1 MALL KEY PLAN AND STORAGE PLAN KI.1 KIOSK DRAWINGS K1.2 KIOSK DRAWINGS K1.3 KIOSK DRAWINGS K1.4 KIOSK DRAWINGS ELECTRICAL El POWER PLAN AND LIGHTING PLAN ES1 ELECTRICAL SPECIFICATIONS PLUMBING P1 PLUMBING PLANS AND DETAILS PS1 PLUMBING SPECIFICATIONS AND DETAILS I RESPONSIBILITIES � I � I ,� ,� fil VJ j , ,,,1 111111; lll lll i, MAPQU E 'ST.; 34- JL { I p 154111 s 53rd Aye 3 57th 5[ S 166kh Ln NS 2r}04 f.Zi](?CIIJYSI Ifi C. n F Permit No. Plar review approval Is subject to errors and om!sSions. Approval of construction documents does not authorize the violation of any adopts code or ordinance. Receipt of approved Id Copy a d conditions is acknowledged: ci 0i Tukwila BUILDING DMSBON PREVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal • and may include additional plan review fees. 5151sq St 1 p t "'S 5 1530_ SEPARATE PERMIT REQUIRED FOR: g r g iMechanical L . .t Electrical Lines Li Gas Piping City of Tukwila [3UILDINO DIVISION Strand2r.34M1 rreck i}r zoct ICI f E Oo8 50 3 Do oa is RECEIVED DEC I 02008 PERMIT CENTEF N INCOMP ETE LTR# 3100 East Rondo' Mill Road Arlington, Texas 76011 817.633.4200 p • 817.633.4153 f This document contains information proprietory to PUNS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Revisions Date A A A Issue Date N r 3 Sea 9205 Drawn By Appv'd By Sheet Title CO O 0 w 0 0 2 w J Sheet Number 10/14/08 Description By A 12/09/08 CITY COMMENTS MTC O CV m t 4( c � V V s a N v en . 0 2 mb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARIJNGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 REGISTERED ARCHITF.tfT ICHAEL R. BLACK STATE OF WASHINGTON /10 Job Number 080294 ds RER Responsibilities, Drawing Index & Bldg. Info. A0.1 A Date Description By A A A A A DIVISION 1 - GENERAL REQUIREMENTS Section 0100 - General Notes A. The "General Conditions" and "Supplementary General Conditions" form a part of the Contract and shall govern the work performed under each section of the Specifications. B. The following General Requirements Supplement supersedes the foregoing General and Supplementary Conditions for Contract work and are hereby considered a part of the Contract Documents. C. All work is to be accomplished in compliance with these plans and specifications. All changes must be approved in writing by WETZEL'S or the owner's representative. All costs incurred by WETZEL'S or the owner's representative as a result of unauthorized changes are the responsibility of the individual(s) making the change. Section 01010 - Summary of the Work A. References and Definitions 1. The Contractor: Is the person or entity identified as such in the Owner- Contractor Agreement, (and is referred to throughout the Contract Documents as if singular and masculine). The term Contractor means the Contractor or his authorized agent. 2. A Subcontractor: Is a person or entity who has a direct contract with the Contractor to perform any work at the site. The term Subcontractor is referred to throughout the Contract Documents as if singular in number and masculine in gender and means a subcontractor or his authorized representative. The Subcontractor does not include any separate contractor. 3. Installer: Is the person or entity engaged by the Contractor or his Subcontractor of sub /subcontractor in the performance of a particular unit of work at the project site, including installation erection, application and similar operations, as installer may be a Subcontractor. 4. In the Plans, Specifications, addenda, and other Contract Documents, the abbreviation "GCC" or "GC" or "TGC" is used. These shall be taken to mean the Contractor. 5. The term "Owner's Representative" shall be taken to have the same meaning as Owner (as if singular and masculine.) The term Owner means the Owner or his authorized agent. 6. The Drawings and Specifications are complementary each to the other and what called for by one shall be as binding as if called for by both. However, the Drawings and Specifications shall be considered inseparable documents and Contractor shall consider both instruments in order to perform the work in accordance with their combined intent. 7. In case of discrepancies in the Contract Documents, Contractor shall first consult with the Owner for clarifications, revision, or further action as may be required prior to starting work affected by the discrepancy. 8. Dimensions shall govern over scale sizes, large scale or full size details over small scale Drawings, and Specifications over Drawings. 9. The Contractor, Subcontractor and installers are cautioned not to scale drawings. Should a dimension not be known or shown, consult the Owner's Representative for advise. B. Project /Work Summary 1. General: The work of this Contract involves and includes the construction of a new WETZEL'S retail store in a leased space at the location specified in the title block. WETZEL'S is referred to herein as, the Owner. 2. Contract Documents indicate the work of the Contract, and related provisions project which may include but are not necessarily limited to the following: a. Existing site conditions and restrictions: (1) Survey and Layout of Work: Contractor shall check carefully all levels and conditions and shall call attention in writing to any discrepancies, before proceeding with the work. Any discrepancies in the information provided on the Drawings or found within the owner's survey shall be reported immediately to the Owner. Contractor will obtain and follow Landlord's construction requirements at no additional cost to the bids. b. Requirements for Owner occupancy at the established date of "Substantial Completion" and prior to final completion of work of Contract. c. Other work to be performed concurrently by Owner. d. Owner - purchased and furnished material/ equipment to be installed under the work of this Contract. 3. This Contract may also include (but are not yet specifically stated herein): a. Pre - negotiated material /equipment orders assigned as work of Contract. b. Pre- purchased subcontracts for Contract, with subcontract amount included Sum. 4. Summary by Reference: Work of Contract can be summarized by reference to the Contract, Instructions to Bidders, Supplementary Conditions, Specification sections as listed in the bound herewith, Drawings as listed in "Schedule of Drawings" bound herewith, addenda and modifications to the Contract Document issued subsequent to the initial printing of this Project Manual, and including, but not necessarily limited to, printed matter referenced by any of these. It is recognized that work of Contract is also unavoidably affected or influenced by governing regulations, natural phenomenon including weather conditions, and other forces outside the Contract Documents. 5. Abbreviated Written Summary: Briefly, and without force and effect upon Contract Documents, work of Contract can be summarized as follows: a. The work includes construction of a retail store on the site as shown, doors, hardware, glazing interior finishes and furnishings including architectural woodwork, floor finishes, acoustical ceilings, and a portion of the signage. b. The work also includes: plumbing, fire protection, heating - ventilating -air conditioning, electrical systems, lighting, and security systems. 6. The Owner will furnish certain materials and equipment However, the work of this Contract includes certain support systems to receive and service Owner's equipment These items will be summarized in the Instructions to General Contractors, in limited fashion, but are also called out in detail under various sections of the work. Section 01011 - Examination of Contract Documents A. Before submitting proposal, each Bidder should carefully examine all Drawings, Specifications, addenda (if any) and all other Contract Documents. B. Submission of proposal implies that Bidder is fully informed regarding all requirements of the Contract Documents, also all site conditions. No additional compensation will be paid to the Contractor due to this failure to be fully informed regarding requirements of the Contract Documents. C. Protection and the safety of persons using the site, parking areas and existing facilities shall be paramount, as well as the non - disruption of essential services. Section 01016 - Owner Occupancy A. The Owner reserves the right to take initial occupancy of the building at the earliest possible date, particularly with regard to delivery and installation of store fixtures, and merchandise. Depending on the progress of the general contractor's work, this may or may not create some inconvenience. The general contractor should anticipate this possibility. Claims for time delays and /or extra costs due to such inconvenience will not be allowed. Section 01017 - Pre - Negotiated Orders A. General: Prior to date of Contract, and for purpose of expediting delivery and for other purposes in Owner's interests, Owner may negotiate costs or make other commitments to be indicated with suppliers of materials /equipment that may be incorporated into the work by Contractor. Those orders and commitments will be assigned to Contractor, and costs place in Contract Sum. Contractor's responsibilities are same as if Contractor has negotiated purchase orders, including responsibility to renegotiate purchases if necessary and to execute final purchase order agreements. A "Schedule of Pre- Negotiated Prices" (if any) will be given to the Contractor or successful bidder, as the case may be. Section 01041 - Supervision, Coordination and Layout A. All work included in the Contract shall be under the constant supervision superintendent who has been employed directly by the General Contractor for a the preceding 6 (six) months. All work shall be in compliance requirements and accomplished within the Base Bid. B. The Contractor shall submit the name of all Subcontractors to Representative for approval prior to awarding of the subcontract work• right to approve or disapprove of any Subcontractors. C. In order to maintain proper coordination and continuity of all branches of work, job superintendents or foreman shall not be changed during the course of the project without prior notice to and approval of the Owner's Representative. D. The Contractor and Subcontractors sha'l carefully examine ALL Drawings and Specifications for the total project and coordinate hi r work with others to avoid delay and shall be responsible to ascertain that the work he installs does not interfere, or it shall be corrected at the installing Contractor's expense. Preoccupation of space by any Contractor or Subcontractor does not give him the right of priority to the space. E. When piping, conduits, ducts or other items are to run in the same general direction, elevation or location, the Subcontractors involved shall request the GC to arrange a conference to determine the proper allocation of the space or position. F. When work is to be installed above ceilings, adequate clearance must be maintained to allow for access, repairs, and removal of all devices. Each Subcontractor shall be responsible for protecting his /her installation from being blocked off by others. Should a conflict occur, he /she shall bring the matter to the attention of the General Contractor for resolution. of a qualified minimum of with Landlord's rules and the Owner's The Owner reserves the G. Each Contractor shall be responsible for any layout associated with the performance of his work. Should a Subcontractor's work be subsequent to and contingent upon layout by another, he shall check said layout prior to proceeding with his work, reporting any discrepancies to the GC. Proceeding with the layout shall be considered as acceptance of the layout. Section 01045 - Cutting and Patching A. Each Subcontractor shall be responsible for the condition and contents of the tenant space. Each Subcontractor shall be responsible to provide all cutting and patching required is to perform and install their respective work. Cutting shall be in a neat, workmanlike manner, and shall be done with coreboring equipment wherever possible. Patching shall be performed carefully, and where necessary shall be done by skilled labor of the respective trade of work being patched. Each Subcontractor shall restore the work to "as new" condition. B. Sleeves, inserts, boxes, etc., for plumbing and heating pipes and electrical conduits will be furnished and installed as specified under the various sections of that work. In case such sleeves are not furnished in time, the Contractor shall form openings in the work, after coordinating with the trades involved `or propel location, and the Subcontractor shall be held responsible for any cutting and patching thereafter in connection with same. All voids between pipes, conduits, etc., and sleeves shall be sealed to comply with Fire Code requirements. C. Each Subcontractor shall do all cutting promptly and shall make all repairs necessary to leave the entire work herein mentioned in a proper condition. D. Portab'e Fire Extinguishers: Supplied by GC - during construction and supplied new at Project Completion - including mounting bracket and sign. E. One standard listed multipurpose dry chemical fire extinguisher, per local code, should be provided and located for each 3,000 square feet of new construction floor or fraction of thereof. Additional extinguishers shall be provided at locations as shown on the drawings, or as directed by Fire Marshal. F. NOTE: The above requirement is the maximum permitted area of coverage per fire extinguisher location. Depending on partition arrargements, amount and location of barricades, obstructions, and combustible materials, additional fire extinguishers may be required. Sound engineering judgment should be used to assure adequate coverage. G. All workers should be instructed in the proper use of fire extinguishing equipment. H. No Contractor or Subcontractor shall endanger and /or damage any work by cutting, drilling, digging or other actions. No Contractor or Subcontractor shall cut or alter the work of other Contractors or Subcontractors without prior written approval by the Owner's Representative. I. Any cost caused by defective and /or ill -timed work shall be borne by the Subcontractor responsible therefore. J. In no case shall any Contractor or Subcontractor cut into any base building components, structural element, beam or column without prior written approval from the Landlord and the Owner. K. Each Subcontractor shall be responsible to follow the progress of the project to in assure that his portion of the work is installed at the appropriate time to avoid unnecessary cutting, patching p ng modifications to his work and /or the work of other Contractors. L. In case any Contractor is required to cut existing work in order to install the work required under his portion of the contract, the Contractor requiring the cutting shall bear the expense of the cutting and all subsequent repairs, patching, and /or replacement. All cutting, patching, repairing, and /or replacing shall meet with the approval of the Owner's Representative. Section 01060 - Permits, Regulations, Codes & Standards A. The Contractor shall secure and pay for all required permits necessary for the execution of his work, except as otherwise stated .herein. B. The Contractor will file plans and pay the filing fee for the building permit. The Contractor shall obtain the building permit and file in all necessary documents as required by local custom. Subcontractors shall file for and pay all fees for their respective permits. C. Contractor shall give all notices and comply with all laws, ordinances, rules and regulations bearing on the conduct of the work as drawn or specified. D. All work installed by the Contractors or Subcontractors shall be in compliance with governing Federal, State and Local Codes. All electrical work shall comply with the National Electrical Code (NEC -date of issue as adopted by local jurisdiction); except where more stringent local or other codes must govern. If any portion of work called for in the Specifications or shown on the Drawings is deemed contrary to the codes and requirements, Subcontractor shall be required to bring the matter to the attention of the GC prior to roughing in so that same can be reviewed for clarification or revision. Installations made without regard to code requirements must be corrected by the Contractor or Contractors without an increase in the contract amount. E. This Contractor shall apply for, pay all fees and obtain the Certificate of Occupancy (C of 0). F. Any "Standard" (ASTM, ASA, etc.) referenced in these Specifications shall be based on the edition and /or amendments of the Standard as specified herein. In cases where the edition or date of the "Standard" is not specified, the edition and /or amendments of the Standard which are current on the date the bids are submitted shall govern. Should a more current edition of a Standard become effective during construction, the Contractor may, with the approval of the Owner, apply the latest edition of the specified Standard. Section 01100 - Alternates /Alternatives A. Specified Manufacturer's Substitutions and Alternatives 1. The following provisions shall govern the bidding of all work. The provisions specified below shall not relieve the Contractor from meeting other requirements set forth elsewhere in the Bidding or Contract Documents. 2. When a brand name is not specified: a. Product used shall meet the specified standards, such as ASTM, etc., if indicated, and shall be of the appropriate design, configuration, type and finish as required to meet the requirement of the intended service. b. Submittal data for products in this category may be in the form of a typed List of Materials and /or Equipment. The list, if used, shall include the name of the item, the proposed manufacturer, the standard of compliance (ASTM, etc.), and a brief description of the pertinent features, as applicable. The Owner reserves the right to request and receive additional submittal data on any item prior to approval. 3. When two (2) or more brand names are specified without further qualifying stipulations: a. In all cases, the first named brand or manufacturer's equipment should be used for the basic design and to determine the space requirements. b. First named brand should be bid unless it will not fit or is not available. c. Should other than the first named brand be used in preparation of the bid, the Contractor shall be responsible to determine and assure that the product of equipment being bid will fit and function in the space allocated. Submission of shop drawings shall be construed as evidence of fit and function in the allocated space. d. In all cases, the product used shall meet the requirements of the intended service, including specified optional accessories, performance, and basic feature. Should one of the named manufacturers offer a range of quality for a particular item, the Contractor shall provide the selection of equal or greater quality than the first named brand in the Specifications. All equality determinations rest with the Owner's Representative and his decisions shall be final. 4. When one (1) brand name only is specified without further qualifying stipulations: a. Contractor's base bid price shall be based on the product specified. 5. Substitutions a. Any material, product, or equipment (other than specified materials, brand, or manufacturers) proposed by the Contractor may be considered by Owner for review. b. In order to qualify for review by the Owrer for a decision on approval, a substitution shall be submitted at the time of the bidding. The proposed substitution shall be clearly identified and shall include the respective add or deduct to the contract base bid amount as defined above. When requested, the Contractor shall submit complete data (including samples, if requested) regarding the substitution to the Owner for review and decision. c. Any substitution must be approved in writing by Owner prior to being used by the Contractor. 6. Alternates a. When requested in the Specifications or on the Drawings, Contractor shall include the appropriate add or deduct to the Contract amount for the alternate as specified. b. All alternates must be approved in writing by Owner prior to being used by the Contractor. Unless said approval is received by Contractor, it is assumed that the Contractor's total bid is based upon specified materials and equipment. c. For alternates to be approved, cut sheets and samples are to be provided. d. It shall be further understood that the use of any approved substitution other than the first named brand in the Specifications shall involve no extension of the project completion date and/ or shall not cause delays in the work of other Contractors unless otherwise stipulated in writing with respective Contractor's bid and /or proposal for Substitution. Section 01150 - Measurement and Payment A. Payments 1. a. Based upon the Applications for Payment submitted to the Owner by the Contractor, the Owner shall make progress payments to the Contractor equal to (90) percent of the value of the material received at the site and work completed at the site in the month for which the request is made. 1. b. Prior to the Final Payment request, the Contractor shall submit a conditional lien waiver for each scheduled value along with the Application for Payment. 2. The Owner shall pay the Contractor on or before (30) days following the receipt of the Application for Payment. Contractor warranty that all material for it is requesting payment have been provided and that all work for which it is requesting payment has been done. 3. The Contractor's payment request shall be made on the Owner's Application for Payment form. 4. The final Payment Request covering the retained percentage will be paid on or before (30) days following the completion of project close -out procedures and receipt of the payment request. Section 01200 - Project Meetings Section 01201 - Site Inspection A. Each Bidder shall visit the project site prior to the preparation of his bid to investigate and determine all conditions on and near the site which could affect the execution of the work. Any Contractor's failure to fully acquaint himself with existing conditions under which the work is to be performed will not be justification for additional compensation. B. The location of the underground utilities, such as sewers, electrical power, water piping, conduits, etc., indicated on the Drawings is as exact as can be determined from available information but its accuracy or completeness cannot be guaranteed. Exact location of these utilities shall be verified by the Contractor prior to excavation. Contractor shall exercise special care when excavating at or near the general location of underground utilities for the safety of workers, as well as for the protection of the utility services. C. Any connections to or relocation of any existing existin utility line requiring re uirin temporary P Y discontinuation of utilities which are in active use shall be scheduled and coordinated with the utility companies and /or the representatives of the Owner. All overtime required for the installation of any such connection and /or relocation shall be included in Contractor's bid. In no case shall the utilities be left disconnected at the end of a working day or weekend unless authorized by representatives of the Owner in writing. Any existing utilities damaged due to the operation of any Contractor shall be repaired to the satisfaction of the Owner or utility company or agency, by the Contractor causing the damage, at no increase in the Contract cost. Section 01203 - Job -Site Administration A. As -Built Drawings 1. The Contractor and the Subcontractors shall maintain at the job -site current, accurate marked -up prints indicating the "as- built" conditions of the representative work. 2. Reproducibles of "as- built" drawings will be sent to Owner prior to submitting for final payment. B. Certificates 1. The Contractor shall secure all certificates of Inspection and of occupancy that may be required by authorities having jurisdiction over the work, including all State, City, and County Departments, the American Insurance Association, Factory Mutual or Insurance Agencies having jurisdiction. The Certificate of Occupancy shall be in force on the same day of construction completion. Section 01310 - Construction Schedule A. The Contractor must prepare and present a "Completion Schedule" for construction at the time of submitting the bid to Owner. Such schedule shall show all items of work, date of start, date of completion and duration of work. All major and critical delivery items shall be flagged and the earliest delivery and latest delivery shall be noted on such schedule. This schedule shall be presented, discussed, and approved by the Owner prior to Contract execution Ability of Contractor to provide such a schedule showing completion within the required time schedule shall be a condition prerequisite to the signing of the Contract. Inability of the Contractor to produce a logical, well thought out schedule shall be cause for rejection of the Contractor's proposal. B. Such schedule shall be approximately 8 -1/2" x 14" and prepared on reproducible material such as vellum or mylar so that revisions and copies can be made. Provide space for the Contractor's name and date. C. It is the intention this be made part of the Contract and shall be maintained, updated and the actual progress charted thereon during the course of the job. Section 01340 - Shop Drawings A. The Contractor shall furnish two blueline copies of Shop Drawings to Owner's Representative as required by the Contract Documents. Delete information which does not apply to the Project. Show dimensions and other selected characteristics. Furnish catalog cuts, if appropriate, in triplicate. Delete material which does not apply to this job. Shop drawings shall be reviewed, noted, and stamped by the Contractor prior to submittal to Owner's Representative. A 5" x 3" space free of graphics or verbage shall be provided on the submittal for the review stamp of Owner's Representative. B. The Contractor shall furnish one each (unless otherwise noted) of material samples required by the Contract Documents to Owner's Representative. C. Submit reports of inspections, tests and approvals required by the Contract Documents to Owner's Representative in duplicate. D. The Contractor shall see that these Drawings are maintained and current, and at the conclusion of the job, all such marked -up prints shall be turned over to the Contractor for transferal of all fo in rmation to one Master Set of reproducible mylar prints of the job. Each Subcontractor shall sign the Master Set attesting to the accuracy of their respective installed work as shown on this set. The GC shall provide and pay for the set of mylar reproducibles of the Contract Drawings. Sepias are not acceptable. E. Upon completion of the "punch list" the contractor shall submit the "as- builts" to the Owner's Representative. The retainage will not be paid until the "as- builts" are submitted and approved. Section 01340 - Sprinkler Shop Drawing Approval A. The Contract Sprinkler Drawing indicates a layout derived from pipe size schedules and tables in accordance with NFPA requirements. The Sprinkler Subcontractor shall provide an approved "calculated" sprinkler system layout. Drawings and calculations for such system shall be submitted to the Landlord's insurance agency for review (prior to fabrication of any material) and approval prior to submission of the Code Review Authority, Engineer or Architect. Drawings and calculations must also be signed and sealed by an Engineer licensed in the state where the subject building is located. All costs for review, permit, signing and sealing of drawings and calculations shall be borne by the Sprinkler Subcontractor. B. Sprinkler heads: All Sprinkler Heads to be semi - recessed, custom color only if Concealed is specified. Section 01400 - Quality Control A. Application of material and /or equipment to work by others constitutes acceptance of that work. Contractor assumes full responsibility for satisfactory application and /or installation. Contractor shall, prior to starting the specific application, notify, in writing, the Owner's Representative of any unsatisfactory work, defect or deficiency which would impair complete and satisfactory application of installation of the work. Section 01410 - Test and Inspections A. The Owner shall pay for all testing. However, the Contractor will be responsible for the cost of test reports that are substandards, or failed, and all appropriate retesting. If the provision of the Contract, Specifications, or any law, building ordinance or code, rule, utility requirement, order or regulation prescribed by any legally constituted public authority, having jurisdiction, require that any work performed by the Contractor or any material therefore, whether complete or incomplete, by tested or inspected, then the Contractor shall have said tests or inspections made, and shall pay all costs incurred by the testing laboratory in connection therewith. B. All tests shall be made by a self established independent testing laboratory, having the facilities to make the test required, and which is satisfactory to the Owner's Representative. C. The testing laboratory shall report the results of all tests in writing to the General Contractor and the Owner's Representative. Section 01500 - Construction Facilities and Temporary Controls A. Scope: Provide and complete all preliminary work and temporary construction as may be reasonably required by the Scope of the Work or as indicated elsewhere in the Contract Documents. B. Temporary Services: 1. Light and Power: Provided by Contractor from location of Landlord's temporary service on -site to be used by all Owner's Contractor(s) to subject space. 2. Heat: Provided by Contractor as necessary to protect the work of all Owner's Contractor(s) and Subcontractors against damage from dampness and cold. System shall be sufficient to maintain a minimum temperature of 50 deg. F except as may otherwise be required in subsequent specification sections. Section 01514 - On -Site Telephone A. The General Contractor is required to maintain an on- site telephone for the use of all parties having any legal responsibility for any portion of the work. All users shall reimburse the GC for all long- distance use. With the exception of such use, all costs for installation, maintenance, operation, and removal of this telephone is the responsibility of the GC. The telephone will remain connected until all work is complete or the store telephone is installed. Must be a land line capable of receiving faxes (cell phones do not qualify) fax machine must be set up on job. Section 01520 Construction Aids Section 01522 - Temporary Enclosures and Protection of Premises A. Contractor shall provide all fences, barricades, guards or such other protection around the work as required by Local, State or Federal (OSHA) regulations or as may be necessary, and shall assume all responsibility for the same, and keep them in repair during the course of the work. All are to be kept free of advertising signs. B. Provide where necessary to protect the public, to provide security to the store, and to confine all dust u and odor to the construction area. C. Barricades shall be built of materials and anchored to structure in a manner approved by Landlord. After removal of barricades, all adjacent structures and finishes shall be restored to their original condition during the entire operation. The Contractor shall make good at his own expense any damage done and leave adjoining property in as good condition as found when building operations were started. D. Welding: 1. Where electric or gas welding or cutting work is done above or within ten (10) feet of combustible material or above space that may be occupied by persons, interposed shields of incombustible materials shall be used to protect against fire damage or injury due to sparks and hot metal. 2. Tanks supplying gases for gas welding or cutting shall be placed at not greater distance from the work than is necessary for safety, securely fastened and maintained in an upright position where practicable. Such tanks, when stored for use, should be remote from any combustible material and free from exposure to the rays of the sun or too high temperatures. 3. Suitable fire extinguishing equipment shall be maintained near all welding and cutting operations. When operations cease for the noon hour or at the end of the day, the surroundings adjacent to welding and cutting operations should be thoroughly wet down. 4. A workman equipped with suitable fire extinguishing equipment shall be stationed near welding and cutting operations to see that sparks do not lodge in floor cracks or pass through floor or wall openings or lodge in any combustible material. The workman shall be kept at the source of work with special hazards for 30 minutes after the job is completed to make sure that smoldering fires have not been started. 5. A qualified electrician shall be in charge of installing and repairing electric or arc welding equipment. Section 01700 - Contract Closeout Section 01710 - Cleaning A. The Contractor shall, prior to the date the Owner's merchandise arrives, comply with c Owner requirements as follows: 1. Remove paint, putty and labels from all glass and wash and polish all glass surfaces. 2. Replace, at Contractor's own expense, all damaged, broken or scratched glass. 3. Remove all marks, stains, soil or dirt from all painted, tiled or laminated surfaces. 4. Vacuum all carpeted areas with commercial type equipment. 5. Clean all new fixtures and equipment and restore to original finish. 6. When any area of the space is used as a shop, storeroom, etc., the Contractor will be held responsible for any repairs, patching, or cleaning arising from such use. 7. The Plumbing Subcontractor shall thoroughly clean all plumbing fixtures removing all paint, stickers, rust stains, and other foreign matter or discoloration, leaving every part in an acceptable condition and ready for use. 8. The Mechanical Subcontractor shall clean all surfaces of all coils, fan housing, fan wheels, and clean or repair air filters, leaving the installation in first -class condition. 9. The Electrical Subcontractor shall wash and otherwise clean all lighting fixtures. Including diffusers. B. Cleaning up by the Subcontractor: 1. During construction, the Contractor shall be responsible for cleanliness of the premises at all times. All Subcontractors shall immediately, upon completion of their work for each phase of construction, room or area, remove all loose debris and leave the area clean and orderly. 2. Cleaning Standards: The standard of acceptability of final cleaning operations shall be equivalent to a professional janitorial cleaning service. C. Cleaning of all painted and finished work: 1. Remove all dirt marks, stains, finger marks and other soil or dirt. D. Removing all temporary protection: 1. Remove all temporary protections and clean surfaces. E. Cleaning of hardware: 1. Clean all hardware, including removal of all stains, dust, dirt, paint, etc. 2. Cleaning of all fixtures and equipment. 3. Each Subcontractor shall, during the process of his work, keep the premises free from rubbish, debris, etc., caused by his workmen. 4. Should any Subcontractor, following the completion of the cleanup work, mar or litter any areas or materials, he shall be held responsible and shall clean the affected areas again. The Contractor shall have the respective Subcontractor replace marred materials and reimburse him for the expended cost. F. cleanup and Debris Removal: 1. At completion of the work and before final acceptance, the entire premises shall be. thoroughly cleaned of all rubbish, debris, etc., caused by this work, both inside and outside. Section 01715 - Certificate of Occupancy A. The General Contractor shall obtain the Certificate of Occupancy on the construction completion date. B. The General Contractor shall obtain and follow Landlord construction guidelines. Section 01720 - Project Closeout Procedure A. Final Inspection: 1. As the work nears completion, each Contractor shall review the requirements of the Contract Documents, inspect the work, and inform all parties involved of work to be corrected or completed before the project can be deemed substantially complete. 2. When, in the opinion of the Contractor, the project is substantially complete, he shall notify the Owner's Representative in writing of this fact, listing those items of work remaining incomplete, the reason incomplete, the reason therefore, and the anticipated date that all remaining work will be completed. Final inspection of the project will then be scheduled. 3. The Owner's Representative reserves the right to cancel and reschedule the inspection if considerably more work remains to be completed or corrected than indicated in the written request for inspection. 4. A representative of the Contractor must be present at the time of inspection. 5. GC to set up mall final inspection with Landlord's Tenant Coordinator to correspond with the Owner's final inspection. 6. Deliver to the Owner's Representative the following items prior to processing the final payment: a. Final Unconditional Waivers. b. All guarantees & Warranty. c. List of Subcontractors address and phone numbers. d. Air balance report. e. Signed off punch list from Owner's Representative and, if applicable, the Landlord Tenant Coordinator. f. All extra materials (per spec.) turned over to store manager. equipment. contacts. g. h. J. Cause the store manager to become familiar with all systems and As -built Drawings. Certificate of Occupancy. All extra equipment to be returned to Owner's Representative. C.C.'S Maintenance policy with phone #'s including after hours/ weekend Section 01740 - Guarantees A. General Guarantee: 1. The Contractor and /or his Subcontractor shall guarantee his work in writing including labor and material, for a period of one (1) year or longer if so specified from the date of final completion of the Contract by the Contractor or from full occupancy of the tenant space by the Owner, whichever date is earlier. However, if at the time of full occupancy of the tenant space by Owner, a portion of the work has not been completed or is found to be defective, the starting date or guarantee for the defective or incomplete portion shall become effective only after same has been complete or corrected by the Contractor. 2. If a portion of the tenant space and /or the work is turned over to the Owner for occupancy and /or operation prior to the completion of the work under contract, the beginning of the guarantee period for the portion occupied will begin from the date of occupancy. In order to receive an adjustment in the guarantee period, the Contractors involved shall each submit a written certificate describing the portion of the work involved. The certificate shall be submitted for signature and shall be effective when signed by the authorized representative of the Owner. 3. Defective work and all damages resulting from same occurring within one (1) year from date of completion of the work under Contract shall be corrected by the responsible Contractor at his own expense. 4. Contractor shall use Owner's Guarantee form. B. Specific Warranty: 1. Manufacturer's equipment warranty shall be for at lease a period of one (1) year as defined in the General Guarantee paragraph. When a manufacturer's standard warranty is for a longer period, or a longer period is called for in the specific equipment Specification, then the longer warranty period as defined by the manufacturer shall govern. In any case the overall effective guarantee period shall not be shorter than the one (1) year period dating from the substantial completion date of the Contract. 2. Contractor shall be required to turn over manufacturer's written guarantee to Owner's Representative prior to receiving finul payment. DIVISION 2 - SITE WORK Section 02050 - Demolition A. The Owner's general contractor is responsible for any and all demolition. The general contractor or his demolition sub contractor shall field verify the existing conditions and the extent of demolition required prior to submitting base bid. There will be no additional compensation for demolition required to do the work. B. Work includes demolition, removal and legal disposition necessary to complete the new work. This typically includes work noted or indicated in the drawings as "remove ", "replace ", "patch ", etc. Cut, patch, and modify existing work, i.e., ceiling, partitions, wall finishes, floor finishes, tile, plumbing, ductwork, piping, lights, wiring, casework, doors /frames, etc., which is shown on the drawings or necessary to do the new work. C. Ail work to be done by skilled workmen, and surfaces patched to receive new work. Contractor to protect all adjacent surfaces and existing building. Erect temporary barricades and dust barriers. Perform noisy and other objectionable work at such times to avoid disturbing other tenants. Remove debris from premises as soon as possible. Do all cutting, fitting and patching to make new work come together. Mechanical or electrical contracts shall re- route any necessary piping ductwork or wiring and sprinklers. No "dead end" sewer, vents or water piping from existing work will be allowed. Coordinate all work with Landlord's Representative. D. Should any hazardous material be encountered during demolition operations, suspend work and notify Owner immediately. RECEIVED DEC 10 2008 PERMIT CENTEF 1 i pa - a-Padign grow] 'PS p 3100 East Rondo' Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions N 3 Seal Drawn By Appvid By Sheet Title cn CO 0 0 I- 0 w C 0 w Sheet Number 10/14/08 mb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 REGISTERED ARCHITECT OV Job Number 080294 ds RER Specifications A0.2 DMSION 3 - CONCRETE Section 03320 - Concrete Floor A. B. ahe on all Scopn: 1. Beady- 'nixe.d wr re e i\S1vl (:94 -69 Materials: F'.irtland Cement: Type 1, As M Fine Aggregate: A=TM 933 -69 Coarse Aggregate: Tulbe IT size 5"/ ASiM 33 69 4. Water: Potable, table lean, and fit to drink Bar Reinforcement: Grade 4O AI:1M AE16 68 Welded Wire baldric. AS IM A18.5 1119 Admixtures: F <.iith Or equal as; Manufactured by Ma ter Builders Co. Exec .rtilan. 1. I r)pi = "tl n . ii r ote d elopnie:ot 35 psi at 28 dm snoop 1 Mardrnu, Dement _ortent 1 I bads (F "' /r) ;er its yard. No water is to tae •:tided arler mixing ono slump tesh r reinforcements: s n` place as ppr e i h:. I II lord aria as required Jrtal_ 24" an st zit SpLc cl u us _ r:. _l:'I IrTer rut vapor banire. be n %r sb._ib Install 6x6 No T each direction weld ci xis:, dipped 12" and tied. Welded mire tabriC: to be '.::et on chairs r ss - , ,." -. .t mid thu_knri.,� point ur . I:Ib at t�., c in both directicms. Finish slabs to a level condition to accomodate finished materials as shown in these drawings. Finish material el shorts shall rte flush with molls finish material surface with no noticeable ramping or elevation changes. 9. Curs, _slabs with chlorinated rubber liquid InaembranP curino / hardening compound to the exposed concrete. 19. Float ;tab and Finish surfaces with steel trowel atter , rooter .heed has disappeared, dusting with dry sand on cement is not permitted. 11. Provide covering, heaters and or fans to assure optimal curing conditions for the first seven days as per ASTM standards. 1 b.. Install control joints cit each column line no more than Pt : ' . __r . ° r - ne and nc .Yule than �_ J in e_ICh direction. 13. Install expansion joints as required by mall conditions. 14. Contractor is responsible to flash patch, scrape car trod the new or existing concrete, slab to provi(tte 0 smooth surface free from holes, bumps, ridges, valleys, or racks prior to the application of any finish flooring materials. 15. Contractor t :a:;k fill any new or existing trench a slab to it's original condition or better if required for floor finisher. DMSION 4 - MASONRY al - I rove a mlaximurid required to return the DMSION 5 - METALS Section 05100 - Structural Metal Framing A. Scope: 1. Contractor shall thoroughly examine drawings for all items which may be required hereunder. The following is a list of items for the bidder's convenience only: Clip angles, pipes, anchor bolts, lead shield, sheet metal. B. Materials: 1. Furnish all miscellaneous metal work indicated or required for a complete installation, with all devices required for properly and permanently securing all items in their appropriate location. C. Execution: 1. Form true to detail with joints of close fit, all in accordance with approved standards of the trade. Provide 24 gauge sheet metal, galvanized for exterior use. Exposed edges of sheet metal to be hemmed. Paint all items of steel after thoroughly cleaning with shop coat or red oxide zinc chromate phenolic resin vehicle primer. DMSION 6 - WOOD AND PLASTIC Section 06050 - Fasteners and Supports A. Materials and methods to secure wood elements together and to other construction. Includes nails, screws, metal connectors, etc. , as may be required herein and /or shown on the plans. Section 06100 - Rough Carpentry A. Scope: 1. Furnish and install all framing as may be required for interior partitions, soffits, ceilings, storefront, cabinets, etc., all as noted and where shown, using materials and methods as indicated and required by standard trade practice, local codes and other applicable standards. B. Materials: 1. Dimension Lumber and Boards: Non - combustible No. 2 Pine or No. 1 Fir, sound, thoroughly seasoned, free from warp. Construct as required for framing, blocking, furring, etc. 2. Plywood: Douglas Fir conforming to DFPA standards, exterior type. Use plywood of Sitka spruce veneer of compressed flake core for substrate for high pressure plastic laminate surfacing. 3. Fastening Devices: Furnish all anchors, bolts, screws, etc., as may be required; non - corrosive and non - staining if exposed to exterior. 4. Preservative: Pressure treat all wood to be permanently fastened into place with "Non -Corn" chemical process as manufactured by Koppers Company, Inc., Forest Products Division, complying with Underwriters Laboratories, Inc., fire hazard classifications of flame spread 15 or less, all such wood to be properly labeled prior to delivery. C. Execution: 1. Use only sound, thoroughly seasoned, new, first quality materials of longest practical lengths and sizes to minimize jointing. 2. Cut and fit all framing members accurately, true to line, level and square, avoiding shims. 3. Coordinate location of all framing, furring, blocking, grounds, and similar carpentry items with all trades. 4. Verify all dimensions, conditions, and shop drawing requirements prior to proceeding with work. 5. Avoid delay of work of other trades dependent upon or affected by carpentry work. 6. Protect all carpentry from damage by work of other trades during construction. Section 06200 - Finish Carpentry A. Scope: 1. In coordination with Owner's Vendor, noted on drawings, all finish carpentry including, doors, finish trim, paneling, high pressure plastic accessories. (Refer to Responsibility Schedule). B. Material: 1. Solid Stock Wood: suit. as required, furnish and /or install, as but not necessarily limited to, frames, laminates, finish hardware, and A. Oak: Select red oak for exposed edges, trim, fascia, drawer sides, etc. Sizes and shapes as detailed. B. Pine: Pine for blocking, etc., mill stamped fire retardant treated. 2. Plywood: A. Oak faced plywood, rotary cut, "A" face grade, ply or lumber core, thickness as detailed. B. Melamine, where exposed as part of fixtures or shelving. C. Birch or maple, where requiring fire code rated. A -C faces, exterior glue, thickness as detailed. C. Execution: 1. All finish materials shall be brought into installation area and allowed to precondition for 48 hours or more. Do not subject materials to direct sunlight, rain, or wide variations in ambient conditions. 2. Install and secure all materials plumb level and true to line, variations in plane in excess of 1:240 shall be removed and reinstalled at Contractor's expense. 3. Moldings to receive transparent finish shall be selected for compatibility of grain and color. 4. No warped or twisted molding shall be allcwed. 5. All moldings to be set plumb, level and true. 6. Moldings shall be installed in muximum lengths possible to minimize joints. 7. All field joints to be tightly fitted and flush. 8. Field joints in running trim to be diagonal ( "scarfed ") joints. 9. Exposed ends of running trim shall have profiled or self mitered returns. 10. All exposed fastening (nails or trim head screws) shall be keep set. 11. All factory finished wood moldings and trim shall be back primed. 12. Blind nailing and concealed type fasteners to be used whenever possible. 13. Large piece or multi- membered moldings to be installed with back blocking to 14. Cope or miter inside corners where applicable, to produce tight fitting joints. Section 06424 - Laminated Plastic (Plastic Laminate) A. Scope: 1. Furnish all necessary materials, labor, and equipment for the complete installation of laminated plastic as shown on the drawings and specified herein. B. Materials: 1. See material schedule. C. Execution: 1. All finish materials shall be brought into installation area and allowed to precondition for 48 hours or more. Do not subject materials to direct sunlight, rain, or wide variations in ambient conditions. 2. Install and secure all materials plumb, level, and true to line, variations in line, or plane in excess of 1:240 shall be removed and reinstalled at Contractor's expense. 3. High pressure plastic laminate to be trimmed with router equipped with edge trimmer. Section 06650 - Solid Polymer Fabrications A. Scope: 1. Furnish all necessary materials, labor, and equipment for the complete installation of solid surfacing material as shown on the drawings & specified herein. B. Materials 1. Homogenous sheet material composed of acrylic resins, fire - retardant filler materials, and coloring agents. See material schedule. C. Execution 1. All finish materials shall be brought into installation area and allowed to precondition for 48 hours or more. Do not subject materials to direct sunlight, rain, wide variations in ambient conditions. 2. Install and secure all materials plumb, level, and true to line, variations in line, or plane in excess of 1:240 shall be removed and reinstalled at Contractor's expense. Section 06600 - Fiberglass Reinforced Polyester A. Scope: 1. Sanitary wall and ceiling panels. B. Materials 1. All sanitary wall panels shall be: Marlite brand FRP(S1000), Marlite brand harmonizing moldings as required, Marlite brand C -375 or C -551 as required. C. Execution 1. Preparation: Sanitary wall panels must be applied over smooth, solid, flat subwall such as drywall or plaster. 2. Conditioning: Panels should be opened and allowed to acclimate for 48 hours prior to installation. 3. Installation: a. Install all panels in stria accordance with manufacturer's installation instructions. b. All moldings must provide for a minimum 1/8" expansion joint to insure proper installation. c. Marlite brand #C -375 or C# -551 adhesives are the only recommended adhesives. 4. Maintenance: Wipe down using a damp cloth and mild soap solution. Refer to manufacturer's specific cleaning recommendations. DMSION 7 - THERMAL AND MOISTURE PROTECTION Section 07200 - Insulation A. Scope: 1. Furnish all necessary materials, labor, and equipment for the complete installation of insulation where specified in the drawings per manufacturer's instructions. B. Materials: 1. Glass fiber thermal insulation for (roof) (ceiling) (wall) assembly as drawings as manufactured by Owens /Corning. 2. All insulation shall meet local fire codes and be non- combustible. C. Execution: 1. Comply with manufacturer's instructions for particular conditions of installation each case. 2. The "R" value of insulation to be of an acceptable level for the given area of the country, in no case shall it be less than Ri 1. indicated in Section 07900 - Sealants A. Scope: 1. Execute all caulking indicated or required. In general, all exposed joints between dissimilar materials. B. Materials: 1. Sealant: Fed. Spec. TT -C -00598 and TT -S -00230 Mono - Lasti -Meric (silicone type), one part Acrylic Terpolymer by Tremco Manufacturing Company in clear or color to match adjacent finish (Submitt sample for approval). 2. Joint Filler: Ethafoam in size and appropriate. C. Execution: 1. Install in strict accordance with the manufacturer's written instructions. Do not apply when temperature is below 40 degrees F without proper heating enclosure. DMSION 8 - DOORS AND WINDOWS Section 08100 - Metal Doors and Frames A. Hollow metal doors shall consist of two flush faces r,f 'li,; gauge, level, one piece quality niece. =;oiararl insulated core b . :ri:l ' r try ath f': . for) and c ement 0 gays hall be 1 gang. Provide t oe rri Hall t, weather trippe s r +h b s_ nvl _r town a tight sea „eal.J it Finish hardware furnished undo metal rolled sheet steel with o nastic. l corner r doors bottom chann; aluminum thr€ mitered, welds floor clip and rs. H or 3M type Y 1743 w\ather label rating or as approved by local code. installed by Contractor. Finish painting incuded in Section 09900. Section 08200 - Wood Doors and Frames A. General Requirements: All wood doors shall meet or exceed the ANSI/NWWDA Industry y Standard I.S. 1 -A Series and AWI Quality Standard for Architectural Flush Doors Species and grade of lumber and wood veneers shall be as described in these standards the moisture content of rII wood r `moor its shall avernre IrrrrF ft r coca owl - flail he at equilibrium dth th sac . re a • hum � y cundit�l at B. Core Cr line or described in the latest er I ion of ANSI A008.1 "Ma torrned equal. 2. Fire Doors: Shall have a mineral _:or rating. (Specify one) Section 08400 - Entrances and Storefronts B. Mlateri 1. Framing Sys polished 1. IrrticleL lyd: ai! net orl+xceed le c rbr ,. UrU E C. Execution: Section 08700 - Hardware edg' to th face Elevations. Detail sections of typical members. Anchorages rind reinforcements. Expansion provisions. iazin vailable f led then position core with 45, 6C' or 90 minute Section 08100 and A. Scope: 1. Furnish all necessary materials, labor, and equipment for the rurn installation equipment (< installation of aluminum framing and tempered glazing, storefront as shown on the drawings and specified herein. 2. Submit manufacturer's product specifications, technical product data, standard details, and installation recommendations for each type of storefront product required Include fabrication methods, finishing, and accessories. Crisp drawings :shall include the tal-owiing: ea, 0 a. 1 -3/4 " nominal dimension; Non- Thermal: Corder Glazed; Screw Spline, Sheer Block or Stick Fabrication. b. System includes perimeter trims, stools, access and perimeter sealing of storefront units. Tempered Glass 1 ' thickness on all storefront clash xcinc � p / a� 1 with glass 01 ,s, edges. brims and anchors, I All glass framing shall be et in correct locations as shown on the irawing:a and shall he level, square, plumb, and in alignment with other avork in accordance with the manufacturer's installation instructions and the Flat Class Marketing Association's FOMA) r,;i,;rrent Glazing Manual. A. Note: Refer to Door Schedule for doors and hardware groups. Section 08800 - Glazing Glass zi nr A. _Ia,.- and Glazing 1. Storefront glazing shall be fully tempered and conform '.o ANSI 297.1, federal standard 16 CFR, categories I and II, cast well as all local authorities have jurisdiction over project. 2. Warpage: Vertical bow or wrap of glass panels shall nct exceed 1/4 in 120" or or prorated amount as measured from glazing head to sill with a straight edge parallel to glass. Glass panes adjoining each other shall be level with no noticeable bowing. 3. The following tolerances are used to assure high duality surface appearances and consistency in edge -work. (Where glazing edges are exposed). A. Seamed edges: The minimum edge work for tempered glass is the removal of the sharpness of a clean cut edge by approximately 1/32" (0.8 MM) to 1/16" (1.6 MM) by seaming the edge. Chips Brie or greater than 1/32" beyond MM) n band the seam , is the surface r �a cn a -i� r r, are e u fac_ of o. glass r , ) J t a e not kernai stable. B. Flat ground edge: Grinding produces a dull matte finsh_ The glass edge is carefully machined flat, with a ground finish. Then a ground (sean1d edr ' , oplii glass to cc pie' e Imo;. ble r all glaz g thic all tl Iishe; The similar 4. Storefront glass panes on this project shall not have gags greater than 3/16" between panes and any glass pane and the adjoining wall surface. 5. Glass shall be cleanly cut, free of chips, bubbles, scrat cries or irregular cleavage, to prevent built -in fatigue or stress patterns. 6. Mirrors shall be 1/4" quality float glass with no noticeratle bubble's, chips , ,varpage or imperfections in the reflecting surface. Mirrors shall rnee't or exceed Federal Specifications DD- C -45FD with satin steel "J" Stylemark on all edges with mitered corners. B. See Section 08400. DMSION 9 - FINISHES Section 09100 - Metal Support Systems A. Scope: Metal non -load bearing framing systems and ceiling suspension systems. Includes furring systems. 1. Metal Studs: All interior partitions shall be constructed as follows: For partitions up to and including 16' -0" in height, use 3 5/8" 20 GA., studs at 16" o.c.; for partitions above 16' -0" in height, use 3 5/8 ", 18 GA., studs at 16" o.c.; all partitions to have 5/8" fire code Gyp. Board. Framing on all partitions designated on plans as "Partition to deck above" shall extend to the bottom of the deck above and shall be sealed air tight with non - combustible materials. 2. Furring Channel: Metal (same material as studs). 3. Align runners along floor, ceiling, and at top of partitions, anchor runners 24" o.c. in 4. Studs to be plumb and true at indicated spacing, do not splice studs; studs and runner flange to have positive screw engagement at each joint. 5. Studs located maximum of 2" from door or window jambs, partition corners, and adjacent partitions. Double studs at all door and window frames. 6. Over door and other framing use a "cut -to- length door head runner" with web flange bend at each end, securely screwed to adjacent jamb studs. Install studs from ceiling runner over door to door head runner and secure at both ends. 7. Reveals shall be sized as noted on drawings. All reveals shall be 16 Ga. minimum metal or aluminum. All shall be pre- finished interior and exposed edges. Install all reveals so edges are flush with finished surface. 8. All exposed sheet metal shall be 20 Ga. galvanized. 9. Any recessed metal strapping for support or wall standards shall be 18 Ga. 10. Framing for any deck shall be 18 Ga. 6" metal studs at 12" o.c. 11. Hanger wire: 9 Ga. galvanized and 16 Ga. tie wire with USG clip anchorage or 12. Storefront steel: Shall be 1/4" thick cold rolled steel as listed on these drawings. B. B. Materials: interf iaStcat work Materials: 13. Connectors: A. Screws on clear anod. alum. sheeting: 1/2" counter sink w/ zinc finish. B. Lag Bolts: 3/4" x 1 1/2" hexhead zinc by Crown Metal. No exposed markings on bolt head. 14. Holes in other work: Provide holes required for securing other work to structural steel members, as approved by landlord, and for passage of other work through steel members. Cut, drill, or punch holes perpendicular to metal surfaces. Do not flame cut holes or enlarge holes by any burning methods. Section 09250 - Gypsum Wallboard A. Scope: 1. Provide all work in accordance with manufacturer's directions, as required herein and as shown on the drawings, for complete erection and finishings for drywall partitions, soffits, column enclosures, etc., including metal studs and accessories as may be required. B. Materials: 1. Products herein specified are identified by reference to United States Gypsum Company. However, similar products of the National Gypsum, and Georgia- Pacific Companies will be acceptable. a. Gypsum Wallboard (Gyp. Bd.): Taper edge 48" wide in lengths as required. Fire Shield 5/8" - one hour fire rating. b. Joint Treatment: Perf -A -Tape and cement. c. Corner Bead: Standard or multiplex types. d. Casing Bead: #200 and #300 only, in sizes as appropriate for edges and recess of board, where exposed. e. Perf -A -Bead and Edge Trim: Perf-A -Trim f. Fasteners: Type S, Bugle head self - drilling, self- tapping, in lengths as required. Use with power screwdriver. C. Execution: 1. Coordinate work with Divisions 5 and 6. Non- combustible wood blocking must be in place prior to installation of gypsum wallboard. 2. Gypsum wallboard to be applied vertically or horizontally to framing with joints centered over framing member flanges. Use wallboard of maximum practical lengths to minimize end joints. Stagger end joints. Place joints on opposite sides of partitions on different studs. 3. Space screws 12" o.c. into studs and 8" o.c. in joint studs, and on ceiling application. Stagger screw placement to anchor wallboard. Do not place screws within 3/8" of board edge. 4. Install metal bead as indicated and as required. 5. Mix and apply joint cement in accordance with manufacturer's directions. 6. Fill joints evenly and fully with cement, center moistened tape on joints and press into cement with board knife leaving sufficient cement under tape for proper bond. Cover with thin cement coat for flush board /tape finish, fill screw heads. Allow to dry. 7. Apply two additional cement coats (allowing 24 hours between coats) where gypsum board will be exposed and scheduled for finish. All joints to be feathered a minimum of 9" on each side from center of joint. Sand to smooth finish. Section 09330 - Ceramic Tile A. Scope: 1. Provide and install ceramic tile, and ceramic wall tile as scheduled. Provide all miscellaneous base and trim shapes as may be required for a complete installation. Install at storefront base and as indicated on plans. Install all trim pieces necessary for completion of tile installation. 1. Ceramic Tile: a. Refer to plans and schedule for locations. 2. Sanded grout for finishing tile joints. Refer to plans for specifications. 3. Penetrating grout sealer. C. Execution: 1. Perform all tile work in accordance with ANSI A108.4. 2. Tile work shall not begin until new concrete is thoroughly cured. 3. Installation of tile work on any surface constitutes acceptance of surface as suitable and Subcontractor accepts full responsibility for results of finish work. 4. Cut or shape tile accurately to accommodate vertical surfaces (e.g., walls, curbs, drains, etc.). File cut edges smooth. 5. Allow tile to set 24 hours prior to grouting. 6. Mix and apply grouting according to manufacturer's direction. 7. Allow grout to set 72 hours after all tile work is completed and cover with 1/8" plywood during construction to prevent damage and wear. 8. Stained, broken or damaged tile is unacceptable. Section 09500 - Acoustical Treatment A. Scope: 1. Provide all Labor arid supply materials and equipment required to install all lay -in tile and Donn suspension system, including wire hangers, main tee runners, cross angle molding, and hold - down clips, if required. 1. Acoustical Ceiling: (A.C.T.; Acoustical Ceiling Tiles) Refer to plans for specifications. 2. Contractor to provide one extra unused carton of each type of ceiling tiles to be storied at the project for Owner's future use. C. Execution: othe ceiling sh eS accept Section 09660 - Resilient tile Flooring USG tees, tentiat caution of Ir, >tall ; - _ . ,Ion syslm accordir nan> ,re ct _ nstall suspension system to comply with all codes for seismic forces, in seismic zones. 3. Secure hangers to structural steel and framing members using metal clips designed for this purpose. Loop and wire tying directly to members is acceptable. Avoid contract with ducts, pipes, etc. Splay only when impossible to install hangers plumb to suspension system.. 4. Secure main runners to hangers 48" a.c. and not more than 6" from ends. Level (not more than 1/8" in 12' -0 ") with hangers taut to prevent displacement under load, Hangers shall not be kinked or bent 5. Provide additional hangers as needed at light fixture locations. 6. Attach cross tees to main runners using manufacturer's clips, maintaining tight contact with main tees with exposed faces in same plane. Connectors must resist twisting. 7. Provide additional hangers cis needed at light fixture locations. 8. Install perimeter molding at junction of ceiling and vertical surfaces. Secure to framing in wall 16" o.c. and not more than .3" from ends. Use lead shield anchors, toggle bolts, or bugle head screws depending on wall condition. Miter cut all corners. Install level (not more than 1/8" in 12' -0 "). 9. Run directionally textured tiles (or patterns) in one direction as shown on plans. 10. Cut panels accurately as required to fit non- standard grid openings. 11. Do field cutting in a neat, inconspicuous manner (no frayed edges). Section 09900 - Painting A. Scope: 1. Provide complete painting and finishing of materials indicated in this section as well as other sections of these specifications and drawings. Conform with the standards of the latest edition of "Specifications of the Painting and Decorating Contractors of America" except as may be modified herein. 2. DO NCT paint the following unless otherwise indicated: Metal surfaces with factory finish; aluminum; wall surfaces not exposed behind store fixtures. B. Materials: 1. See Finish Schedule for materials. Colors are as specified on plans. C. Execution: 1. Remove or protect items not requiring paint. Apply all materials in strict conformance with the manufacturer's printed instructions. Use only admixtures and thinners as appropriate of a type recommended by the manufacturer of the particular paint or stain product. 2. Paint all exposed portions of grilles and louvers the same color as adjacent surfaces, including roof - mounted equipment, support frames, and related surfaces requiring painting. 3. Gypsum board walls must receive one coat of Latex primer prior to finish coats. 4. Metal surfaces must receive one coat of oil base primer prior to finish coats. 5. Treat all galvanized iron to be painted by washing with mineral spirits, followed by one coat of good commercial metal etch. 6. Remove all splatterings and leave work in a clean and finished condition. Section 09990 - Adhesives A. Scope: 1. Furnish all necessary materials, labor, and equipment for the complete application of adhesives for laminated plastic products and various finishes per manufacturer's recommendations. B. Materials: 1. Miracle Adhesives Corporation brand #27 contact adhesive for bonding decorative laminates, etc. (1- 800 - 647 - 2253). C. Execution: 1. Brush, roller coat, or spray separately both surfaces, allow to dry. 2. Bond both surfaces together. 3. Trim excess finish material. 4. Clean up any excess adhesive off laminated plastic finish using manufacturer's recommended solvent. Test on material to check for damage or discoloration prior to clean -up of adhesive. DMSION 10 - SPECIALTIES A. Scope: 1. The following specialties are to be either provided and installed by the General Contractor per plans and the following specifications, or furnished and installed by the Owner's Vendor. 2. Install according to drawings and manufacturer's directions for each substrate encountered. 3. All fastening devices must be of sufficient number and type to accessories in place when subject to normal use. 4. Replace all damaged items, Section 10400 - Signage A. Storefront Sign: 1. The General Contractor is responsible storefront sign and logo. The storefront sign and Owner's Vendor. a. Contractor to provide electrical service; 120V - 20A with shut -off switch located within 6' -0" of sign (above ceiling). b. Contractor to provide adequate access and wall support to hold one person on ladder to allow installation /maintenance of sign equipment. radius rout Advance C 2. Special Notes: c. General Contractor and possible structural requirements. Additional unless otherwise stated. Section 10426 - Plaque Signage A. Toilet Room Pictogram: 1. The General Contractor b. sign 60" above f Section 10521 - Portable Fire Extinguishers A. Dry Chemical 10 #ABC fire extinguisher, as shown on fixture /equipment plan building codes. Mount as required by local code with surface mounted hangers. Section 10800 - Toilet and Bath Accessories A. Scope: 1. The following specialties are to be either provided and installed by the General Contractor per plans and the following specifications, or furnished and installed by the Owner's Vendor. 2. Install according to drawings and manufacturer's directions for each substrate encountered. 3. details. 4. details. details. 4. 5. 6' C ack backs 7 East yr Moun list Rohn door wit tap, ished floor and adjacent to latch side of door. 7. Bobrick brand equipment pion. 8. Bobrick brand logo is furnished will furnish and install sign. ictogram: white syn sue, St. P 3. All fc eninr' ' "s n of sufj•:ient •umt cd ' a ' old accessorie pla mai use. liii opera ►IV9. :vvw r 'Gb COMPLIANCE leaving accessories clean and open tional. APPROVE ! DEC 1 7 2008 to coordinate the installati n of t h° e Of Tukwila and in st l le V RI DIVISIO installer to coordinate sign installation schedule and support to be provided by General Contractor and per local B. MatL1 - ials: 1. Bobrick brand Toilet Tissue Dispenser, Double Roll, Model B -6867, as shown on toilet room details. 2. Bobrick brand Paper Towel Dispenser, Model B -2621, as shown on toilet room details and equipment plan. Bobrick brand Grab Bar, Model B -5507 x 36, Satin finish, as shown on toilet room Bobrick brand Grab Bar, Model B -5507 x 42, Satin finish, as shown on toilet room Bobrick brand 18" x 36" Mirror, Model B -165, as shown on toilet room details. 6. REI RigidRak Coat hook 988SC, mount to back of toilet room door @ 48" o.f.f. Soap Disp., Model B -2111, as shown cm toilet room details and Sanitary Disposal Box, Model B -270, as shown on toilet room RECEIVED OEC 10 2008 PERMIT CENTEF This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Welsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions Date A 0 0 0 0 0 N 3 MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Seal 9205 ICHAEL R. BLACK '.TATE OF WASHINGTON Job Number Drawn By Appv d By Sheet Title Sheet Number 'PS n % au 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f CD O 0 I- O 2 w 0 0 2 w J 10/14/08 Description mrb REGISTERED ARCHITEC PIO 080294 ds RER Specifications A0.3 By FINISH SCHEDULE ROOM /AREA FLOOR BASE WALLS CEILING CEIUNG HEIGHT REMARKS REMARKS (E) MALL FLOORING REFER: KIOSK DRAWINGS REFER: KIOSK DRAWINGS OPEN OPEN TO MALL CEIUNG SEE KIOSK DRAWINGS I 01 KIOSK W WASTE EXISTING CONCRETE 4" RUBBER BASE PAINT EXISTING LAY —IN V.I.F. G.C. SHALL REPLACE BROKEN OR MISSING TILE PAINT: BENJAMIN MOORE (SEMI — GLOSS) COLOR BRILLIANT WHITE I 02 I REMOTE STORAGE I P -5 I MK. DESCRIPTION SUPPLIER QTY. BASE REMARKS/ MANUFACTURER ELECTRICAL REQUIREMENTS PLUMBING REQUIREMENTS REMARKS VOLTS H.P. AMPS PHASE CONN CW HW FIN W WASTE INDIRECT 0 NOT USED (--) NOT USED O METAL STORAGE LOCKER KEC/T 1 O SHELVING— 4 TIER HIGH KEC/T 3 SETS LEGS 18" DEEP X 4' —O" WIDE S.S. SHELV'G ® 1 DR. UPRIGHT FREEZER KEC /T 1 CASTERS TRUE T -23F SINGLE DOOR 115 1/2 9.5 1 C 15AMP CIRCUIT ® 1 DR. UPRIGHT REFRIGERATOR KEC /T 1 CASTERS TRUE T -23 115 1/3 7.5 1 C 15AMP CIRCUIT KITCHEN EQUIPMENT SUPPLIER TO PROVIDE CUT — SHEETS ON ALL SUPPLIED EQUIPMENT TO T.G.C. 10 Date 12/09/08 Description CITY COMMENTS By MTC A A A A A .� WETZEL'S PRETZELS Remote Storage SPACE #52305C I 02 I (E) REMOTE STORAGE II 7 II 7 II I II II FREEZER Scale 1/4' =1' -0' L 12' —O" VERIFY IN FIELD 4 8_x 1 L \ \ )9220 (E) Remote Storage Floor Plan UP TO L3 P° f) Uuutrnd TERRACE Scale 1/4' =1' -0' KITCHEN EQUIPMENT SCHEDULE T TENANT / OWNER KEC KITCHEN EQUIPMENT CONTRACTOR TGC TENANTS GENERAL CONTRACTOR C CHORD D DIRECT CONNECT G.C. SHALL CLEAN/ RE —LAMP EXISTING LIGHTS. VERIFY PROPER WORKING ORDER. (E) Remote Storage RCP EXISTING LAY —IN CEIUNG GRID AND ACCOUTICAL TILES TO REMAIN. G.C. SHALL REPLACE BROKEN, STAINED, OR DAMAGED TILES. • Storage Location 102 sq ft i,nna+r' ) M SEARS 14 44 WETZEL'S PRETZELS Kiosk Space #9240 0 Second Level Mall Key Plan No Scale r macys // de • • analailatataallaalgad R IBOYE woo 20'—O" WAN. FUTURE KIOSK NOTE: G.C. TO CONFIRM EXACT PLACEMENT OF KIOSK W/ MALL MGMT. PRIOR TO START OF CONSTRUCTION. ELEVATOR EXIT TO PAFIKING GARAGE K e r'm` e _ __ / 1 OPEN TO BELOW / / I / I / / MALL PUBLIC RESTROOMS CODE COMPLIANCE APP O ED DEC 1 7 2008 CI Tukwila BUILDIN5 DIVISION I • / • I I I I RECEWED DEC 10 2008 PERMIT CENTER pdles deign group This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents moy not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsels Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions N 3 Seal 9205 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f Job Number Drawn By Appv'd By Sheet Title CD 0 0 F- 0 w 0 0 2 w Sheet Number 10/14/08 HAE R. BLACK iE OF WASHINGTON A1.1 rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 REGISTERED ARCHITECT Pi 080294 ds RER Mall Key Plan and Storage Plan 0 Date 12/09/08 Description CITY COMMENTS By MTC A A A A A 2' -1 CARRIAGE WORKS KIOSK CONSTRUCTION SCOPE AND RESPONSIBILITY CARRIAGE WORKS WILL PROVIDE ALL MATERIALS TO BUILD THE KIOSK IN A PROFESSIONAL MANNER AS PER APPROVED PLANS. PROVIDE ONE CARRIAGE WORKS PROJECT MANAGER AT THE LOCATION TO HELP IN THE SUPERVISION OF INSTALLATION OF THE KIOSK FOR NOT MORE THAT 8 HOURS, WITHOUT PRIOR ARRANGEMENTS. THE KIOSK WILL BE CONSTRUCTED OF FIRE — RETARDANT — TREATED MATERIAL IN COMPLIANCE WITH SECTION 2303.2 ALL FOAM PLASTICS WILL HAVE A MAXIMUM HEAT RELEASE RATE NOT GREATER THAN 100kW (105 Btu /h) WHEN TESTED IN ACCORDANCE WITH THE EXHIBIT BOOTH PROTOCOL IN UL 1975 ALL ALUMINUM COMPOSITE MATERIAL WILL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE — DEVELOPED INDEX OF NOT MORE THAN 450 WHEN TESTED AS AN ASSEMBLY IN THE MAXIMUM THICKNESS INTENDED FOR THE USE IN ACCORDANCE WITH ASTM E 84 ALL GLASS WILL BE " TEMPERED SAFETY GLASS CARRIAGE WORKS PLUMBING SCOPE OF WORK AND RESPONSIBILITY 1. FURNISH A.O.SMITH WATER HEATER MODEL # ECJN -40 The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. fl The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. \ / L L LL L L L LLL L L LLL_L LLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLL 0 2. PLUMB FROM WATER HEATER TO THE 3 COMPARTMENT AND HAND SINK FAUCETS ONLY 3. SUPPLY A 3 COMPARTMENT SINK FROM ADVANCE TABCO MODEL # 94— K6 -18D WITH FAUCETS 4. SUPPLY AND INSTALL A HAND SINK FROM REVERE MODEL # KQ1515D5PBS2 WITH SOAP DISPENSER AND FAUCET 5. ALL OTHER ROUGH AND FINAL PLUMBING TO BE DONE BY G.C. 18' I DOOR CAk'/A SE CAkk//t SE SCOPE AND INDEX PAGE 1 DECK VIEW 2 FRONT ELEVATION 3 BACK ELEVATION 4 END ELEVATIONS 5 OPERATOR'S 1 6 OPERATOR'S 2 7 FINISH CALLOUT 1 8 FINISH CALLOUT 2 9 EQUIPMENT 10 EQUIPMENT SCHEDULE 11 ELECTRICAL LAYOUT 12 ELECTRICAL SCHEDULE 13 / /OAKS h \WETZEL'S PRETZELS BACK 18' FRONT 8" f 3' — 1877 Mallard Ln. Klamath Falls, Oregon 541) 882 -0700 5 ' 8' 10' SINK 1877 Mallard Ln. Klamath Falls, Oregon J ` / (541) 882 -0700 WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED REVISION / ISSUE ND. DATE PROJECT NAME WESTFIELD SOUTHCENTER INDEX 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 1 DRAWN BY— V BRUHN WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED i °N / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTHCENTER FRONT ELEVATIONS 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 3 DRAWN BY— V BRUHN PROJECT NAME WESTFIELD SOUTHCENTER The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. J J � CAPP/ GE CAPP/AGE 1877 Mallard Ln. Klamath Falls, Oregon (541) 882 -0700 ( 1 877 Mallard Ln . Klamath Falls, Oregon (541) 882 -0700 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 2 DRAWN BY— V BRUHN 5 ' 2 8 r- - 22 - -I C -X03 8' -3" 3' -8" 1 8' 8" 3 "-- LLLI_LLI_l_LLLI_LLI_LLI_L _ LLLLLLLLLLLLLLLLLLL _ LLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLL _ LLLLLLLLLLLLLLLLLLL LLLLLLLLLLLLLLLLLLL _ LLLLLLLLLLLLLLLLLLL I I I I I I I I I I I I I I I I I I I 7 , — 4 „ 5' 3' -6" 8 8 FINAL NOTES - APPROVED BY ;x r WETZEL'S MALL UL & NSF LISTED ttEVISION / ND- DAT j PROJECT NAME WESTFIELD SOUTHCENTER BACK ELEVATIONS 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 4 DRAWN BY— V BRUHN kb/lb/VW rum CODE COMPLIANCE APPROVED DEC 1 7 2008 City Of Tukwila BUILDING DIVISION_ RECEIVED DEC 10 2000 PERMIT CENTEF Revisions Seal C Job Number Drawn By Appv'd By Sheet Title Sheet Number 3100 East Rondo! Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Dote co CD 0 0 H- 0 w 0 0 w K1.1 10/14/08 0 N IL Q C V m V v D N v N —V tn h 0 S2 rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 0% REGISTERED ARCH) fEG!/ ICHAEL R. BLACK TATE OF WASHINGTON a. 080294 ds RER Kiosk Drawings 3' -6" LLLLLLLL LL_L_L_L_L_L_L LLLLLLLL . LLLLLLLL LLLLLLLL LLLLLLLL LLLLLLLL 0 3'- 1 2„ 1 0' The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. _LLL _LLL _LLL _LLL _LLL _LLL _LLL I I I The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. 3 1 0 „ y / 3' - L 8” f ICE T 7'-4” L2' -8 "-J L3' 58" 6 ' -9 2" SINK WALL 18' 0110 _• l ( I BACK COUNTER VIEW 10' -8" WATER HEATER 8' 5 FINAL NOTES INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S36I9T (B &W WHITE TILES) DONE BY G.C. WETZEL'S MALL APPROVED BY UL & NSF LISTED ( tI VISION / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTHCENTER OPERATOR'S 2 r I' -2" 2' -4" 2' -4" 8 CA/A3J CAk7/A 3i 8 L 8" - I'' l 4 2 0'- 04" //o INC MAIN LUG LOAD CENTER OPENING 1877 Mallard Ln. Klamath Falls, Oregon 541) 882 -0700 —� X I 877 Mallard Ln. Klamath Falls, Oregon (541) 882 -0700 IOXI8 KIOSK WETZEL'S PRETZELS I 0 -09 -08 PAGE 5 DRAWN BY— V BRUHN IOX20 KIOSK WETZEL'S PRETZELS I 0 -09 -08 PAGE 7 DRAWN BY— V BRUHN WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED &tEVISICN / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTH CENTER END ELEVATIONS J OPENING FOR ADA TURN AROUND 00 8' DOOR VIEW 2' -24" 3' -62" 2' 32" 2' -5 "� FRONT COUNTER VIEW 0 '-6 0 FINAL NOTES INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S3619T (B &W WHITE TILES) DONE BY G.C. WETZEL'S MALL APPROVED BY UL & NSF LISTED i ttEVISION / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTH CENTER OPERATOR'S I ( The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. 1 _2 CA/A WO INC, D3 1 1877 Mallard Ln . Klamath Falls, Oregon `541) 882 -0700 I OX 1 8 KIOSK WETZEL'S PRETZELS I 0 -09 -08 PAGE 6 DRAWN BY— V BRUHN J CODE COMPLIANCE PPROVE DEC 1 ` 7 7.0 Cad B pit c XM1.Cti RECEIVE DEC I 0 2000 (JERMlT CENTER pins deep irou 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p 0 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions Date A A A A A A Seal u) O ci O 2 w 0 z O w J 10/14/08 Description 0 N Q C V m V N ter. v D � v V ) ..1Ic V) 0 2 m"b MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARUNGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Job Number Drawn By App'/d By 9205 Sheet Title Sheet Number REGISTERED ARCHITEf;v .iICHAEL R. BLACK TATE OF WASHINGTON 080294 ds RER Kiosk Drawings K1.2 By Pte EQUIPMENT SCHEDULE Date • ITEM MODEL VOLTS AMPS COMMENTS RECESSED LIGHTING IN BEAM LIGHT BOX — I PEPSI DISPENSER CORNELIUS IMPULSE I -6W- - 120 2. NSF APPROVED MID UL LISTED SUPPLIED AND INSTALLED BY OTHERS 2 GOURMET ICE SYSTEM BUNN MD# ULTRA -2 120 22 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I ICE MAKER MANITOWOC MO# QY -0274A 120 I0 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I OVEN BAKERS PRIDE MD# P44S 206 35.4 UL LISTED SUPPLIED AND INSTALLED BY OTHERS I OVEN CART SEDLE CRAFTS'EN #WPMOC SUPPLIED AND INSTALLED BY OTHERS HAND SINK 15 X 15 304 STAINLESS STEEL WITH SOAP DISPENSER NSF APPROVED IIMBIN SUPPLIED BY CARRIAGE WORKS 'SEE PAGE I FL SCOPE OF WORK I HOT WATER MACHINE BUNN MD# H5E- 18-120 120 15.4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I WATER HEATER A.O.SMITH ECJN -40 240 18.8 UL LISTED SEE PAGE I PLUMBING SUPPLIED BY CARRIAGE WORKS SCOPE CF WORK 1 3 COMPARTMENT SINK ADVANCE TABCO D# 948-18D M — K NSF APPROVED SEE PAGE I PLUMBING SUPPLIED BY CARRIAGE WORKS SCOPE OF WORK 4 24- DRYING RACK METRO WALL MOUNT NSF APPROVED SUPPLIED AND INSTALLED BY CARRIAGE WORKS I MOP SINK SUPPLIED AND INSTALLED BY OTHERS MDO:R HOBART MD# HL200 120 8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I MIXER CART SEETLE CRAFTSMEN CO. #WPMOC NSF APPROVED SUPPLIED AND INSTALLED BY OTHERS 1 MICROWAVE AMANA COMMERIAL PRODUCTS MD# RCS IODA 120 13.8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 REFRIGERATOR BEVERAGE —AIR MD# UCR27 -3 115 4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 HEATED DISPLAY WITH 1 ADDITIONAL WIRE RACK A. J. ANTUNES & CO. ROUNDUP MD# DCH -320 115 15 Ell- LISTED SUPPLIED AND INSTALLED BY OTHERS I JET SPRAY CORNELIUS MD# EJI —A8851 1 15 5 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 4 LIGHT BOX EDGELIT LIGHT BOX 22- X 28' 115 2 SUPPLIED AND INSTALLED BY CARRIAGE WORKS A Date Description By I / - RECESSED LIGHTING IN BEAM LIGHT BOX — A I _ L L L L L L L L L L L L L L L L L L L_ L L _LLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLL LLLLLLLL _LLLLLLL_LLLLLLL LLLLLLL _LLLLLLLLLLLLLLLLLLLLLL / / \ A Date Description By A A A A A TOP OF WALLS, INSIDE WALLS, AND ALL CABINETS ARE WILSONART #10776 -60 KENSINGTON MAPLE FROSTED GLASS WITH WETZEL'S PRETZELS CLEAR ETCHED TILE DONE BY OTHERS LED LIGHTING ABOVE 8" KICK The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. SWING DOORS SIGNAGE PEPSI DISPENSER GOURMET ICE SYSTEM JET SPRAY LLLLLLLL L LLLLLLL LLLLLLLL LL LLLL LL LLLLL L LLLLLL LLLLLL r The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. I I I — LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _ LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLL LLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL a 0 TILE DONE BY OTHERS LED LIGHTING ABOVE 8" KICK ` LED LIGHTING LETTERS ARE SINTRA BLUE WITH ABOVE 8" KICK SINTRA BRIGHT YELLOW BACK \WETZEL'S PRETZELS / GROUND LIGHT BO RECESSED LIGHTING IN BEAM HEATED DISPLAY _LLL _LLL _LLL _LLL _LLL _LLL _LLL I I I CAkR/A 3E — GOURMET ICE SYSTEM EPSI BOX RACK SPACE OVEN CART PAPER TOWEL HOLDER UNDER COUNTER WATER HEATER ICE MAKER DOOR IS CHEMETAL #927 LIGHT STAINLESS CAk'/A6E CHEMETAL #927 LIGHT STAINLESS I ENDER COUNTER / REFRIGERATOR WETZEL'S PRETZELS MAN SIGNAGE GLASS WITH VINYL BACKING (SEMI GLOSS) VIVA GOLD LIGHT BOX LIGHT BOX CHEMETAL #927 LIGHT STAINLESS / /OAKS INC 15" X 15" HAND SINK WITH SOAP DISPENSER IIOT WATER MACHINE —GLASS WITH VINYL BACKING SEMI GLOSS VIVA GOLD UNDER COUNTER MICROWAVE CLEAR GLASS WETZEL'S PRETZEL FROSTED ETCHED TRIM IS CORIAN LINEN DENJAMIN MOORE 2020 -50 MELLOW YELLOW PAINTED WITH GLASS COVER 1877 Mallard Ln . Klamath Falls, Oregon (541) 882 -0700 IGNAGE 4 24" WIRE DRYING SHELVES WALL MOUNT RACKS ON WALL ABOVE SINK MIXER ON A CART MOP SINK DROP SHELF INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S3619T (B &W WHITE TILES) DONE BY G.C. WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED l TISION / ISSUE NO DAZE PROJECT NAME WESTFIELD SOUTHCENTER FINISH CALLOUT j IOX18 KIOSK WETZEL'S PRETZELS I 0-09-08 PAGE 8 DRAWN BY— V BRUHN WETZEL'S MALL FINAL NOTES APPROVED BY ■ UL & NSF LISTED \ J I- EVISION / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTHCENTER EQUIPMENT J 2 1877 Mallard Ln . Klamath Falls, Oregon (541) 882 -0700 IOX18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 10 DRAWN BY— V BRUHN BACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD LIGHT BOX BACK PAINTE GLASS SHERWI WILLIAM SEMI GLOS VIVA GOL BACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD CORIAN LINEN LIGHT BOX LED LIGHTING ABOVE 8" KICK LED LIGHTING ABOVE 8" KICK WETZEL'S PRETZELS MURAL W ETZEL'S PRETZEL SIGNAGE COVERING ELECT. DOOR CHEMETAL #927 LIGHT STAINLESS ACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD CHEMETAL # 927 LIGHT STAINLESS IGHT BOX TILE DONE BY OTHERS FINAL NOTES INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S3619T (B &W WHITE TILES) DONE BY G.C. wFTZEL'S MALL APPROVED BY UL & NSF LISTED IS°N / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTH CENTER FINISH CALLOUT 2 The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. I- The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. 1 � CAkk'/A E3E CAk'k'/A Ei / /OP K5 INC / 1877 Mallard Ln . Klamath Falls, Oregon / `541) 882 -0700 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 9 DRAWN BY— V BRUHN FINAL NOTES APPROVED BY PROJECT NAME WESTFIELD SOUTHCENTER SHEET 1 877 Mallard Ln. Klamath Falls, Oregon 97601 (541) 882 -0700 10 X 18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE II DRAWN BY— V BRUHN CODE p 3 va WED �. DEC Ng Orfultvilla lt BUILDING VISION RECEIVED DEC 10 2008 PERMIT CE'NTEF I p s °e gT© l 1 N 3 Seal 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date 10/14/08 Revisions rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 Job Number Drawn By Appv'd By Sheet Title Cr) 0 0 0 I— O W 0 Z 0 w J Sheet Number REGISTERED ARCHITE HAEL R. BLACK TINE OF WASHINGTON 080294 ds RER Kiosk Drawings K1.3 PI o EQUIPMENT SCHEDULE Date # ITEM MODEL VOLTS AMPS COMMENTS A I PEPSI DISPENSER moans DrPULSE 1 -8UF —I 120 2. NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 2 GOURMET ICE SYSTEM BUNN MD# ULTRA -2 120 22 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS ICE MAKER MANIIOWOC MD# QY -0274A 120 10 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS OVEN BAKERS PRIDE MD# P44S 208 35.4 UL LISTED SUPPLIED AND INSTALLED BY OTHERS I OVEN CART SEEYLE CRAFTSMEN! CO. #WPMOC NSF APPROVED SUPPLIED AND INSTALLED BY OTHERS I HAND SINK 15 X 15 304 STAINLESS STEEL WITH SOAP DISPENSER NSF APPROVED SEE PAGE I PLIILEBING SUPPLIED BY CARRIAGE WORKS \SCOPE OF WORK I HOT WATER MACHINE BUNN MD# H5E— I8—I20 120 13.4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 WATER NEATER A. O. SMITH ECJN -40 240 18.8 UL LISTED SEE PAGE I PLUMBING SUPPLIED BY CARRIAGE WORKS SCOPE OF WORK 3 COMPARTMENT SINK ADVANCE TABCO MD# 94— K8-18D NSF APPROVED SEE PAGE I PLUMBING SUPPLIED BY CARRIAGE WORKS SCOPE OF WORT( 4 24- DRYING RACK METRO WALL MOUNT NSF APPROVED SUPPLIED AND INSTALLED BY CARRIAGE WORKS I MOP SINK SUPPLIED AND INSTALLED BY OTHERS 1 MIXER HOBART MD# HL200 120 8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS MIXER C ART SIEYLE CRAFTSMEN CO. #WPMOC NSF APPROVED SUPPLIED AND INSTALLED BY OTHERS 1 MICROWAVE AMANA COMMERIAL PRODUCTS MD# RCS IODA 120 13.8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I REFRIGERATOR BEVERAGE —AIR MD# UCR27 -3 115 4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I HEATED DISPLAY WITH I ADDITIONAL WIRE RACK A. J. ANTUNES & CO. ROUNDUP MD# DCH -320 115 15 ETL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 JET SPRAY CORNEIIUS MD# EJI —A8651 115 5 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 4 LIGHT BOX EDGELIT LIGHT BOX: 22- X 28' 115 2 SUPPLIED AND INSTALLED BY CARRIAGE WORKS A Date Description By A A A A A CARRIAGE WORKS ELECTRICAL SCOPE OF WORK AND RESPONSIBILITY I, TO SUPPLY AND INSTALL ONE SIEMENS 200 AMP 120 / 240 VOLT SINGLE— PHASE, 4 WIRE, BREAKER PANEL MODEL# G2040 MB200 MAIN LUG LOAD CENTER 2. TO SUPPLY AND WIRE ALL GFI RECEPTACLES FOR REQUIRED EQUIPMENT PER DRAWINGS 3. RUN WIRE FOR HOT WATER HEATER TO JUNCTION BOX. ANY OTHER REQUIRED WIRING AND FINAL HOOK UP DONE BY G.C. FOR WATER HEATER. 4. WIRE TRACK LIGHT AND SIGNAGE SWITCHES 5. ALL WIRING RAN THROUGH FLEX CONDUIT. ALL WIRE, RECEPTACLES, AND JUNCTION BOXES TO BE NEC STANDARD AND UL APPROVED 6. ALL FINAL JUNCTION BOXES AND BREAKER PANEL HOOK UP TO BE DONE BY G.C. 7. ALL PHONE LINES TO BE BY G.C. GOURMET ICE SYSTEM— EPSI ICE MAKER JET SPRAY The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Corriage Works, Inc.. G OURMET ICE SYSTEM PEPSI P MPS DmG 111 —P OS J � em VEN JUNCTION BC FOR KIOSK A SWITCHES I FOR TRACK LIGHTS I FOR SIGNAGE `— MICROWAVE EATED DISPLAY EFER NOTES ALL WIRING TO MEET NEC CODE CAiIA6[ GFI 115 15 AMPS SINGLE PLUG 220 50 AMPS JUNCTION BOX 4 FLEX 115 15 AMPS SWITCH FLEX CONDUIT OT WATER MACHINE WATER HEATER JUNCTION BOX SSEMBL'T ACCESSORY MIXER 200 AMP MAIN LUG LOAD CENTER MARKED WIRES TO BE CONNECTED INTO THE MAIN LUG LOAD CENTER MAIN PANEL BOARD WILL BE LABELED. ALL CIRCUITS AND JUNCTION BOXES T BE COLOR COATED . ALL RECEPTACLES BE GFI \ 1877 Mallard Ln. Klamath Falls, Oregon \ 541) 882 -0700 / WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED &RVtUM / ISSUE NO- DATE PROJECT NAME WESTFIELD SOUTHCENTER ELECTRICAL LAYOUT 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 12 DRAWN BY— V BRUHN The data in this document incorporates proprietary The Carriage Works, Inc.. Any party accepting this does so in confidence and agrees that it shall not in whole or in part, nor disclosed to others without of The Carriage Works, Inc.. rights of document be duplicated the consent CAJ7A SE / /010( _5 LNG 877 Mallard Ln. Klamath Falls, Oregon 97601 (541) 882 -0700 FTNAI FINAL NOTES APPROVED BY S. PROJECT NAME WESTFIELD SOUTHCENTER SHEET 10 X 18 KIOSK WETZEL'S PRETZELS I 0-09-08 PAGE II DRAWN BY— V BRUHN Pa CODE COMPLIANCE APPROVED DEC 7 20 OW Of Tukwila i BUILDDIGIVI REDEW EP DEC 10 2000 PERMIT CENTEI I eco :rou 3100 East Rondo! Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date 10/14/08 Revisions Seal C 9205 Drawn By App'1d By Sheet Title CI) CO 0 0 0 S w 0 z 0 w J rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Job Number Sheet Number REGISTERED ARCHITEC CHAEL. R. BLACK (ATE OF WASHINGTON 080294 ds RER K1.4 Kiosk Drawings 2ND FLOOR 1ST FLOOR / B / / -11 II � II Keyed Notes: EXISTING ELECTRICAL JUNCTION BOX. VERIFY IN FIELD EXACT LOCATION. T.G.C. SHALL VERIFY IF EXISTING CONDMONS MATCH KIOSK ELECTRICAL ENTRANCE. OTHERWISE PROVIDE NEW STUB —UP LOCATION COORDINATED WITH KIOSK ELECTRICAL SERVICE ENTRANCE OPENING. ELECTRICAL SERVICE FEEDER AND CONDUIT CONTINUES TO ELECTRCIAL ROOM AND LANDLORD PANEL. VERIFY CONDUIT SIZE, ROUTING, AND DISTANCE IN FIELD. PROVIDE RECEPTACLE ON EXISTING DEDICATED CIRCUIT. COORDINATE EXACT LOCATION WITH CONSTRUCTION MANAGER IN FIELD PRIOR TO CONSTRUCTION. CONTRACTOR SHALL VERIFY EXISTING CONDIONS AND NOTIFY ARCHITECT IF A DISCREPANCY EXISTS. EXISTING LIGHTING BY LANDLORD TO REMAIN. VERIFY EXISTING CONDITIONS IN FIELD. GENERAL CONTRACTOR TO PROVIDE AND INSTALL ONE CAT -5 DATA UNE FOR EACH POS /CASH REGISTER LOCATION FROM THE POINT OF INTERNET SERVICE PROVIDER ENTRY LOCATION TO EACH POS /CASH REGISTER LOCATION TERMINATING IN AN OUTLET BOX WITH A FEMALE RJ -45 PLUG FOR EACH POS /CASH REGISTER. ALL SERVICE CONDUCTORS, FEEDERS AND BRANCH CIRCUITS SHALL BE GROUNDED AS REQUIRED BY THE 2002 NATIONAL ELECTRICAL CODE. CONTRACTOR SHALL VERIFY LOCATION OF LANDLORD'S DISTRIBUTION IN FIELD BRIOR TO BID. t A HIDDEN UNE REPRESENTS EQUIPMENT WHICH IS EXISTING OR BY THE LANDLORD A SCUD UNE REPRESENTS NEW EQUIPMENT TO BE INSTALLED BY THE ELECTRICAL CONTRACTOR FREEZER ANY ALUMINUM WIRING THAT IS DISCOVERED DURING ELECTRICAL RECONFIGURATION SHALL BE REMOVED FROM THE PREMISES AND REPLACED WITH COPPER CONDUCTORS. Storage Room Power Plan SCALE 1/4" = T-0" T.G.C. SHALL VERIFY 100 AMP 24 CIRCUIT PANEL WITH 100 AMP MAIN BREAKER AS PROVIDED AND INSTALLED BY KIOSK VENDOR. T.G.C. SHALL VERIFY PANEL LOADS ARE BALANCED. 4 #2 THW & 1 #8 GROUND BY T.G.C. IN EXISTING 2" C. T.G.C. SHALL VERIFY LENGTH OF FEEDER RUN IN FIELD PRIOR TO BID. METER AND METER BASE IN LANDLORD'S DISTRIBUTION ROOM BY POWER COMPANY. (VERIFY IN FIELD) CIRCUIT BREAKER IN LANDLORD'S DISTRIBUTION ROOM BY T.G.C. ELECTRICAL CONTRACTOR SHALL SUPPLY 100 AMP 30 CIRCUIT BREAKER AS REQUIRED BY LANDLORD. CONTRACTOR SHALL VERIFY IN FIELD LANDLORDS DISTRIBUTION EQUIPMENT. CONTRACTOR SHALL PROVIDE BREAKERS OR FUSES AS REQUIRED TO COORDINATE LANDLORDS DISTRIBUTION EQUIPMENT WITH THIS RISER DIAGRAM. Kiosk Riser Diagram SCALE None 1. General Notes: "VERIFY IN HELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E.EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDTION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED. IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. 2. WHERE EXISTING EQUIPMENT (LIGHTS, DIFFUSER, TOILETS, ETC) ARE TO BE REUSED, WHETHER IT IS RELOCATED OR REUSED IN THE EXISTING LOCATION, EXTREME CARE SHALL BE TAKEN TO PREVENT DAMAGE DURING THE RENOVATION OF THE STORE. WHERE DAMAGE OCCURS, THE EQUIPMENT SHALL BE REPLACED TO THE SATISFACTION OF THE ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER. ALL ITEMS TO BE THOROUGHLY CLEANED, IF REQUIRED, PAINTED, AND ANY OTHER MAINTENANCE NEEDED TO BRING EQUIPMENT UP TO LIKE NEW CONDITION. THIS INCLUDES RELAMPING ALL LIGHTS REUSED. 3. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO THE BUILDING STRUCTURE OR BUILDING UTIUTIES CAUSED BY ANY SLAB PENETRATIONS. IT IS RECOMMENDED THE FLOOR BE X —RAYED PRIOR TO ANY SLAB PENETRATIONS. 4. THE GENERAL CONTRACTOR AND ELECTRICAL SUB — CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENANTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM, AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. r - -' K I T.G.C. RESPONSIBLE FOR ELECTRICAL I SERVICE UP TO PANEL IN KIOSK AND FOR FINAL CONNECTION TO ELECTRICAL PANEL �— LZ PANEL AND CIRCUITS WITHIN THE KIOSK BY KIOSK VENDOR. J EXISITNG JUNCTIIN BOX. RELOCATE IF NECESARY TO MATCH KIOSK ELECTRICAL SERVICE OPENING LOCATION. DISCONNECT SWITCH LEGEND EP #/#/# QUANTITY OF POLES FUSE RATING SWITCH RATING (TERMINALS) Kiosk C Power Plan CODE COMPLIANCE APP WED DEC Cif Tuktlila BUILDING DIVISION / F = = L _ I- O RECEIVED DEC 10 2008 PERMIT CENTS E 0 u N rs deep grow] 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction, This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 10/14/08 Description Issue Date Revisions Date A A A A A A Seal cD 0 D O w 0 z 0 LJJ mb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARUNGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 REGISTERED ARCHITE (� CHAEL R. BLACK ATE OF WASHINGTON Job Number Drawn By Appv d By Sheet Title Sheet Number JLP DAR Power Plans E1 080294 By GENERAL SCOPE EACH CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH THE CONSTRUCTION DETAILS BEFORE SUBMITTING BID. NO ALLOWANCES WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. THE GENERAL CONDITIONS OF THE GENERAL SPECIFICATIONS, ALONG WITH ALL APPUCABLE INSTRUCTIONS TO BIDDERS SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. REQUIREMENTS FOR BIDDERS AND CONTRACTORS WHICH ARE CONTAINED IN OTHER SECTIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED BINDING UNDER THIS SECTION, UNLESS OTHERWISE NOTED HEREIN. INSPECTION OF SITE PROPOSALS ARE ACCEPTED WITH THE ASSUMPTION THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTIITY LOCATIONS. THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. PERMITS ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. CODE REQUIREMENTS ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS AND OWNER'S INSTRUCTIONS, AND SHALL SATISFY ALL APPUCABLE CODES, ORDINANCES, OR REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT. ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. MATERIALS AND WORKMANSHIP 1. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS AND, UNLESS OTHERWISE SPECIFIED, SHALL BE NEW AND FREE FROM ANY DEFECTS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. 2. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION AND, UPON COMPLETION, THE INSTALLATION SHALL BE THOROUGHLY CLEANED AND ALL DEBRIS REMOVED FROM THE SITE. CODES AND REGULATIONS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN OR SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE WITH SUCH CODES, HE /SHE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY 1. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS WORK. HE /SHE SHALL MAKE GOOD ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS /HER CONTROL AND NOT TO HIS /HER FAULT OR NEGLIGENCE. HE /SHE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. 2. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE JOB AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF /HERSELF, OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGES IN THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE ADEQUATE TIME AT THE PROPER STAGE OF CONSTRUCTION TO FULFILL HIS /HER CONTRACTS. THE OWNER SHALL BE CONSULTED TO RESOLVE ANY QUESTIONS WHICH MIGHT ARISE BETWEEN TRADES AS TO THE PLACING OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OF STRENGTH OF THE STRUCTURE. SUBSTITUTION OF MATERIALS MANUFACTURER'S NAMES ARE LISTED HEREIN TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF NE TENANT, THE SUBSTITUTE MATERIAL IS OF A QUALITY AS GOOD OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, THE PURPOSE FOR WHICH THE ITEMS SPECIFIED WERE INTENDED. SHOP DRAWINGS SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND SUCH OTHER ILLUSTRATIVE MATERIAL AS MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THE CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING CONSTRUCTION. DRAWINGS AND SPECIFICATIONS 1. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROWNG THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL OR ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. 2. SHOULD THE CONTRACTOR DEEM IT NECESSARY TO MAKE CHANGES TO ITEMS SHOWN ON CONTRACT DRAWINGS, THE SHOP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL RESPONSIBILITY THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS /HER CONTRACT. HE /SHE SHALL PRODUCE COMPLETE FINISHED OPERATING SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS /HER WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THE SUB - CONTRACTOR WITHOUT ADDITIONAL CHARGE TO THE TENANT. ELECTRICAL GENERAL ALL WIRING SHALL MINIMALLY CONFORM TO THE STANDARDS OF THE NATIONAL ELECTRIC CODE AND MEET ALL LOCAL REGULATIONS. UGHTING AND POWER PANELS ALL LIGHT AND POWER PANELS SHALL BE GENERAL ELECTRIC OR SQUARE D UTILIZING BOLTED BREAKERS WITH INTEGRAL MAIN BREAKER SIZE PER PLANS. STEP DOWN TRANSFORMERS STEP DOWN TRANSFORMERS SHALL BE EQUAL TO GENERAL ELECTRIC OR SQUARE D 600 VOLT CLASS, "DRY TYPE ", SINGLE OR THREE PHASE PER PLANS, CLASS "R" INSULATION WITH MULTIPLE TAPS ABOVE AND BELOW RATED VOLTAGE. OUTLET BOXES OUTLET BOXES SHALL BE PRESSED STEEL KNOCKOUT TYPE CASE IRON WITH DRILLED, TAPPED, AND PLUGGED HOLES OR PVC. CAST IRON BOXES SHALL BE HOT DIPPED GALVANIZED OR SHERARDIZED. ALL BOXES SHALL BE OF PROPER CODE SIZE FOR THE NUMBER OF WIRES OR CONDUITS PASSING THROUGH OR TERMINATING THEREIN. STANDARD SIZE SHALL BE 4" SQUARE. ALL COVER PLATES /SWITCH PLATES SHALL BE G.E. THERMOPLASTIC "WHITE ". CONDUIT 1. ALL CONDUIT SHALL BE RUN CONCEALED IN FINISHED AREAS. ALL CONDUIT UNDER GROUND OR IN CONCRETE SLAB SHALL BE RIGID CONDUIT. ALL OTHER CONDUIT MAY BE "THIN WALL ". ALL OUTLETS SHALL BE FLUSH MOUNTED. ALL CONDUITS SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO THE BUILDING CONSTRUCTION AND SHALL BE LEVEL 2. CONTRACTOR WILL PROVIDE NECESSARY CABLES, JUMPERS, ETC. TO INSURE CONTINUOUS GROUND IN CONDUIT SYSTEM. 3. E.C.R.'S REQUIRE TRUE THREE WIRE DEDICATED AC LINES. THIS IS A TRUE GROUND NOT A NEUTRAL CONDUIT MUST NOT BE USED AS THE ONLY GROUNDING MEANS. 4. ALL WIRING CONDUITS, ETC. REQUIRED FOR THE PROPER CONTROL OF THE HVAC SYSTEMS SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL SUB - CONTRACTOR. THE MECHANICAL SUB - CONTRACTOR SHALL SUPPLY THE CONTROLS AND WIRING DIAGRAMS TO THE ELECTRICAL SUB - CONTRACTOR. ALL UNITS SHALL BE PROVIDED WITH INDIVIDUAL DISCONNECTS AT EACH UNIT IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. 5. WHERE STORE IS ON ANY LEVEL BUT GROUND LEVEL, THE TENANT'S GENERAL CONTRACTOR SHALL RUN ALL CONDUIT FOR ELECTRICAL FLOOR OUTLETS AND TELEPHONE FLOOR OUTLETS TIGHT AGAINST THE UNDERSIDE OF THE SECOND FLOOR LEVEL THE SECOND FLOOR STRUCTURAL SLAB SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS SHOWN ON THE PLANS. 6. ALL TELEPHONE WIRE SHALL BE INSTALLED IN CONDUIT. ALL WIRE SHALL BE COPPER. CONDUCTORS 1. NO ALUMINUM WIRING IS ACCEPTABLE. 2. NO. 10 AND SMALLER, SOLID CONDUCTOR, COPPER TYPES, TW, THW, THWN, R, RH, RHW, WITH IDEAL WINGNUTS AND SCOTCHLOCK CONNECTORS. 3. NO. 8 AND LARGER, STRANDED CONDUCTOR, COPPER TYPES, THW, THWN, RHW, WITH SOLDERLESS BOLTED PRESSURE CONNECTORS. 4. FIXTURE WIRING, WIRING IN CHANNELS OF FLUORESCENT FIXTURES SHALL BE EITHER RHH ON THERMOPLASTIC "APPLIANCE WIRE" - 105 DEGREE C COPPER (CSA TYPE THW). 5. MINIMUM SIZE, SHALL BE NO. 12 AWG, TYPE THWN, EXCEPT FOR CONTROL CIRCUITS. EQUIPMENT IDENTIFICATION 1. IDENTIFY ALL EQUIPMENT AND APPARATUS WITH ENGRAVED BAKELITE NAMEPLATE OR IMPRESSED, PLASTIC NAME STRIP. 2. FURNISH A TYPEWRITTEN CIRCUIT DIRECTORY CARD It' ALL LIGHTING AND POWER PANELS. TIME CLOCK ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL SEVEN (7) DAY 24 HOUR TIME CLOCK FOR STOREFRONT SIGNAGE. TIME CLOCK SHALL BE AMF PARAGON 7000 SERIES 7- DAY TIME CONTROL WITH MANUAL HAND TRIP OR EQUAL. RECEPTACLES 1. CONVENIENCE OUTLETS /RECEPTACLES SHALL BE NEMA 5 -15R RATED AT 125VAC/15A AS MANUFACTURED BY HUBBELL, LEVITON, PASS AND SEYMOUR, OR EQUAL. RECEPTACLE FACE SHALL BE WHITE WITH A STAINLESS STEEL COVER PLATE. 2. OUTLETS /RECEPTACLES FOR DEDICATED CIRCUITS WITH ISOLATED GROUNDS SHALL BE 20A /125VAC, NEMA 5 -20R AS MANUFACTURED BY HUBBELL (OR EQUAL) WITH ORANGE NYLON RECEPTACLE FACE AND MATCHING ORANGE THERMO PLASTIC WALL PLATE WITH THE WORDS "ISOLATED GROUND" ENGRAVED THEREON.. 3. ALL DUPLEX RECEPTACLES AND OVERHEAD GRILLE SWITCH PLATES SHALL BE LOCATED 15" A.F.F. TO CENTERLINE OF RECEPTACLE UNLESS OTHERWISE NOTED ON PLANS. 4. GROUND FAULT INTERRUPTER RECEPTACLES SHALL BE AS FOLLOWS: A. FOR INTERIOR APPLICATIONS: INSTALL GFI RECEPTACLE DESIGNATED TO TRIP AT 5 MA IN 1 /30th OF A SECOND RATED AT 115VAC /20A AS MANUFACTURED BY HUBBELL OR EQUAL. B. FOR EXTERIOR APPLICATIONS, INSTALL GFI RECEPTACLE AS DESIGNED FOR TRIP AND RATING ABOVE. RECEPTACLE SHALL BE MOUNTED IN A BOX RATED NEMA 3R AND SHALL COVER PLATED AS MANUFACTURED BY HUBBELL OR EQ. 5. LOW PROFILE SERVICE 3OSD �R C PTAC�E �I WITH COVER PLATES SS309DS & S 19B AN HUAN HU BE L C 1 LO ELL FRAME HOUSING SC3098 ES GF5352 RECEPTACLE. TEMPORARY SERVICES C THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS OF TEMPORARY SERVICES: TELEPHONE - THE TENANT'S GENERAL CONTRACTOR SHALL INSTALL A JOB SITE TELEPHONE AND NOTIFY TENANT AS LISTED ON SHEET A -1 OF THE TELEPHONE NUMBER AND THE NAME OF THE SUPERINTENDENT. 2. TEMPORARY ELECTRICITY - TEMPORARY ELECTRIC SERVICE REQUIRED IN THE PERFORMANCE OF THE CONTRACT SHALL BE FURNISHED AND PAID FOR BY THE CONTRACTOR WHO SHALL FURNISH, INSTALL, AND MAINTAIN ALL TEMPORARY OVERHEAD CONSTRUCTION, METERS, DROPS, AND OTHER WIRING AND FITTINGS FOR BOTH LIGHT AND POWER AT LOCATIONS REQUIRED IN THE WORK AND SHALL BEAR THE COST OF MAKING THE SERVICE CONNECTIONS. BEFORE FINAL ACCEPTANCE, TEMPORARY ELECTRICAL SERVICE FACILITIES INSTALLED BY THE CONTRACTOR SHALL BE REMOVED, AND THE SERVICE CONNECTIONS SEVERED IN ACCEPTABLE MANNER. 3. COST OF LANDLORD PROVIDED UTILITY SERVICES - IF THE LANDLORD ELECTS TO PROVIDE TEMPORARY UTILITY SERVICES, THE CONTRACTOR WILL BE SO INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE PROVISIONS OR COORDINATE WITH LANDLORD'S GENERAL CONSTRUCTOR TO PAY THE COST OF SAID TEMPORARY CONSTRUCTION AND UTILITY SERVICES. NOTE FOR TENANT GENERAL CONTRACTOR: IT IS THE RESPONSIBILITY OF THE TENANTS GENERAL CONTRACTOR TO MAKE USE OF APPLICABLE NOTES & SPECIFICATIONS LISTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. E. EXISTING L LANDLORD C. TENANT'S GENERAL CONTRACTOR RESPONSIBILITIES T. TENANT V. TENANT VENDOR x cn � N w A ELECTRICAL A -1 A B A -2 A -3 A -4 A -5 A -6 A B C D E A -7 A -8 A -•9 A -10 A -11 A -12 A -13 A -14 A -15 A B C D A -16 A B MAIN ELECTRICAL SERVICE MAIN SERVICE CONDUIT FROM LANDLORD ELECTRICAL ROOM TO SPACE MAIN ELECTRICAL SERVICE CONDUCTORS BRANCH MONITORING CIRCUIT BREAKER (IN LANDLORD ELECTRICAL ROOM) ELECTRICAL PANELS STEP DOWN TRANSFORMER CONTACTORS & TIME SWITCH V V ALL LAMPS & BULBS V V LIGHT FIXTURES KIOSK STORAGE AREA OFFICE TOILET EXIT ROUGH -IN TO KIOSK LIGHT FIXTURES FINAL CONN. TO KIOSK LIGHT FIXTURES KIOSK CONVENIENCE OUTLETS SIGN OUTLET FINAL CONN. TO SIGN rums- 4."." A A fe A T R FINAL CONN. TO HVAC EQUIP. FINAL CONN. TO EWH TEMP CONTROL WIRING DEC 1 7 YUUi TELEPHONES PLYWOOD PANEL BOARDS I- EQUIPMENT -.Al- FLOOR BOXES & EMPTY 3/4" COND. (IF REQ'D) I .. k.ICyVI_ ILINVVIICI WALL BOXES & EMPTY 3/4" COND. 1.1:At- PIN UIVI 1UN FLOOR OUTLETS EMPTY COND. & FLOOR BOXES (IF REQUIRED) FINAL WIRING L C V V V V V V V V T V L C V V V V V V V V V C V RESPONSIBILITY NOTES 1. ALL WIRING, CONDUITS, ETC., REQUIRED FOR H.V.A.C. CONTROLS SYSTEMS SHALL BE THE RESPONSIBILITY OF THE LANDLORDS ELECTRICAL SUBCONTRACTOR. THE LANDLORD'S H.V.A.C. CONTRACTOR SHALL SUPPLY THE CONTROLS AND WIRING DIAGRAMS. 2. THE LANDLORD SHALL PROVIDE 3. ELECTRICAL SERVICE SHALL BE 2" CONDUIT W/ PULL STRING 120/208, 30, 4W 4. THE LANDLORD'S GENERAL CONTRACTOR SHALL RUN SERVICE CONDUITS AND PLUMBING LINES TIGHT TO THE SECOND FLOOR STRUCTURE. THE FLOOR SLAB SHALL BE CORED AS REQUIRED TO INSTALL SERVICE STUBS, FLOOR BOXES, ETC. 5. IF DRAWINGS CALL FOR THE REUSE OF EXISTING EQUIPMENT, THE T.G.C. SHALL VERIFY THAT ALL SUCH EQUIPMENT IS IN PROPER WORKING ORDER, OR TAKE THE NECESSARY STEPS TO ACCOMPLISH SUCH. IF REPLACEMENT IS REQUIRED, USE THE EQUIPMENT AND HARDWARE AS SPECIFIED ON THESE SCHEDULES OR AS CALLED OUT IN THE SPECIFICATIONS ON THIS SHEET. ALL SUCH ITEMS MUST MEET ALL GOVERNING CODES AND STANDARDS OF PRACTICE. SYMBOL LEGEND 0 C 4- X €H nj 0 c 0 • SD GFI WP NL EM CONDUIT (ELECTRICAL METALLIC TUBING -- E.M.T.) CONCEALED IN CEILING, WALLS OR ROUTED TIGHT TO THE UNDERSIDE OF FLOOR SLAB IF LEASED SPACE IS LOCATED ON A LEVEL ABOVE THE GROUND FLOOR. HOMERUN TO PANEL (PANEL I.D. & CCT ADDRESS AS SHOWN) CONDUCTORS CONTINUE IN EMT TO OTHER EQUIPMENT ON CCT. TELEPHONE SIGNAL CONDUCTORS IN COND. W /GALV. PULL WIRE. CONDUIT (RIGID METAL CONDUIT - -RMT) CONCEALED IN SLAB. INCANDESCENT FIXTURE - TYPE INDICATED - RECESSED IN CEILING INCANDESCENT FIXTURE - TYPE INDICATED - WALL MOUNTED INCANDESCENT FIXTURE - TYPE INDICATED - SURFACE MOUNTED FLUORESCENT FIXTURE - TYPE INDICATED - RECESSED IN CEILING FLUORESCENT FIXTURE - TYPE INDICATED - SURFACE MOUNTED FLUORESCENT FIXTURE - TYPE INDICATED - CROSSHATCHING INDICATES A FIXTURE ON 24 HOUR 'LOCK -ON' CCT. FIXTURE IS EQUIPPED WITH BATTERY PACK BALLAST FOR EMERGENCY LIGHTING. INCANDESCENT TRACK HEAD - TYPE INDICATED - SURFACE MOUNTED. INCANDESCENT TRACK - SURFACE MOUNTED TO CEILING. EXIT LIGHT ON 24 HOUR 'LOCK -ON' CCT. EQUIPPED WITH BATTERY BACK -UP. JUNCTION BOX. EQUIPMENT CONNECTED AND LOC. INDICATED WALL SWITCH DISCONNECT SWITCH (DISC. SW.)- FUSED OR NON -FUSED PROGRAMMABLE TIME CONTROL SWITCH. THERMOSTAT. AS SPECIFIED AT MS1. SINGLE RECEPTACLE OUTLET (SIMPLEX). DUPLEX RECEPTACLE OUTLET. RECESSED FLOOR SIMPLEX. MAY APPEAR WITH DUPLEX AND QUADRUPLEX SYMBOLS AS INDICATED. TELEPHONE OUTLET. WALL/CABINET MOUNTED AS INDICATED. TELEPHONE OUTLET RECESSED IN FLOOR. MOTOR. (LOCATION /EQUIPMENT CONNECTION AS INDICATED.) SMOKE DETECTOR IN RETURN AIR STREAM. 'GROUND FAULT INTERRUPT'. 'GFI' MAY APPEAR WITH ANY RECEPTACLE SYMBOL WEATHER - PROOF. 'WP' MAY APPEAR WITH ANY EQUIPMENT. NIGHT LIGHT EMERGENCY LIGHT RECEIVE DEC '1 0 SUMO PERMIT CENTEI "pins ee :r©u Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Revisions Date A A 0 A 0 A Issue Date 1 0/14/08 N 3 Seal 0 0 a I- O w a z O w 9205 Job Number Drawn By Appv d By Sheet Title Sheet Number Description REGISTERED ARCHITE (tt ICHAEL R. BLACK STATE OF WASHINGTON JLP DAR ES1 080294 Electrical Specifications 3100 East Rondo! Mill Road Arlington, Texas 76011 817.633.4200 p • 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and moy not be reproduced or disclosed to others without the prior written consent of PDMS Design Group By rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 KIOSK PLUMBING FDCTURE SCHEDULE DESCRIPTION MANUFACTURER MODEL # ACCESSORIES PLUMBING REMARKS WASTE I.W. VENT HAND SINK PROVIDED AND INSTALLED BY KIOSK VENDOR TBD — — 2" — INDIRECT WASTE CONNECTION BY T.G.C. FLOOR SINK JOSAM 49000 SERIES — 3" — 2" PROVIDE FLANGE AS REQUIRED. MOP SINK STERN — WIWAMS MTB -2424 T -10 —VB SINK FITTING 3" — 2" FAUCET SHALL INCLUDE INTEGRAL VACUUM BREAKER 3 —COMP SINK PROVIDED AND INSTALLED BY KIOSK VENDOR TBD — — 3" — INDIRECT WASTE CONNECTION BY T.G.C. WATER HEATER PROVIDED AND INSTALLED BY KIOSK VENDOR TBD — — 3/4" — INDIRECT WASTE CONNECTION BY T.G.C. SODA DISPENSER PROVIDED AND INSTALLED BY KIOSK VENDOR TBD — — 3/4" — INDIRECT WASTE CONNECTION BY T.G.C. GREASE TRAP SHIER PRODUCTS PATG -2025 INTEGRAL FLOW CONTROLLER 3" — 2" 25 GPM, 98 LB, 3" INLET. PROVIDE EXTENSION TO GRADE AS REQUIRED. 1. General Notes: "VERIFY IN FIELD" OR "EXISTING" MEANS THE CONTRACTOR IS TO CONFIRM THE ITEM SHOWN ON THE DRAWING (I.E.EQUIPMENT, DUCT, WIRE, ETC.) EXISTS AT THE SITE AND IS IN GOOD WORKING CONDITION. SHOULD THE CONTRACTOR FIND THAT THE EQUIPMENT, DUCT, WIRE, ETC. IS NOT THE EQUAL TO THAT SHOWN ON THE DRAWING, IT IS TO BE REPLACED. IF THE CONTRACTOR HAS ANY QUESTION ABOUT WHETHER IT IS EQUAL TO WHAT IS SHOWN ON THE DRAWING, THE CONTRACTOR IS TO CONTACT THE DESIGN ENGINEER AND TENANT'S PROJECT MANAGER FOR APPROVAL, CONTRACTOR IS TO NOTIFY TENANT'S PROJECT MANAGER AND DESIGN ENGINEER IN WRITING OF ALL REPLACEMENT ITEMS PRIOR TO CONSTRUCTION. 2. THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO THE BUILDING STRUCTURE OR BUILDING UT1UTIES CAUSED BY ANY SLAB PENETRATIONS. IT IS RECOMMENDED THE FLOOR BE X —RAYED PRIOR TO ANY SLAB PENETRATIONS. 3. THE GENERAL CONTRACTOR AND MECHANICAL SUB — CONTRACTOR SHALL VERIFY AND INCLUDE IN THEIR FINAL BID ALL LIFE SAFETY, SMOKE /FIRE ALARM SYSTEMS NEEDED TO BRING TENENTS SPACE COMPATIBLE WITH THE LANDLORD'S SYSTEM, AND CURRENT WITH LOCAL AND STATE CODES. FAILURE TO DO SO SHALL RESULT IN NO EXPENSE TO THE TENANT. Keyed Notes: O CONNECT TO EXISTING DOMESTIC WATER PIPING PROVIDED BY LANDLORD. COORDINATE EXACT LOCATION FOR STUB —UP WITH KIOSK MANUFACTUERER. O SINKS ARE PROVIDED BY KIOSK MANUFACTURER WITH KIOSK. PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL INDIRECT WASTE AND VENT UNES. O AIR ADMITTANCE VALVE OR "STUDOR" VENT IF ACCEPTABLE TO LOCAL AUTHORITY HAVING JURISDICTION (AHJ). STUDOR VENT SHALL BE ACCESSIBLE FOR POSSIBLE FUTURE REPLACEMENT. CONTRACTOR SHALL VERIFY VENTING REQUIREMENTS WITH AHJ AND PROVIDE ISLAND LOOP VENT IF REQUIRED BY THE AHJ. ® WATER HEATER PROVIDED AND INSTALLED BY KIOSK VENDOR. PROVIDE DRAIN PAN WITH DRAIN UNE. T.G.C. SHALL VERIFY CLEARANCE REQUIREMENTS AND ADJUST LOCATION AS REQUIRED. O CONNECT NEW SANITARY WASTE UNE TO EXISTING LANDLORD SERVICE. COORDINATE EXACT LOCATION FOR STUB —UP WITH KIOSK MANUFACTUERER. VERIFY ELEVATIONS OF PIPE ALLOWS FOR PROPER SLOPE OF WASTE UNES. HAND SINK SODA DISP. FLOOR SINK GREASE TRAP MOP SINK 3 —COMP 31 Kiosk Sanitary Sewer Riser SCALE None O NOTE: CONTRACTOR SHALL COORDINATE ROUTING OF ALL WASTE PIPING WITH KIOSK MANUFACTURER PRIOR TO INSTALLATION. ALL SANITARY SEWER PIPING IS CAST IRON. DO NOT USE P.V.C, SANITARY PIPING IS TO SLOPE AT 1/4" PER FOOT, PIPE LEGEND COLD WATER (TYPE 'L' COPPER) HOT WATER (TYPE 'L' COPPER) FILTERED WATER (TYPE 'L' COPPER) VENT (DWV COPPER, CAST IRON, OR PVC IF ALLOWED) SANITARY SEWER (DWV COPPER, CAST IRON, OR PVC IF ALLOWED) CONNECTION TO EXISTING / COORDINATE WITH KIOSK VENDER — XACT LOCATION OF WATER SERVICE EIRANCE OPENING. O Kiosk C Plumbing Plan 1 SCALE 1/4 - 1-0 KICV ALIN J rut', CODE COMPLIANCE AIM O DEC 1 7 2U08 City Tukwila BUILDING DIVISION ® ® � Y Y 6 7 = W M 0 0 i M MOP SINK RECEIVED DEC 102000 PERMIT CENTER p Th ogo groo 3100 East Rondo! Mill Road Arlington, Texas 76011 817.633.4200 p • 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and moy not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date 1 0/14/08 Revisions Date A A A A A A Seal 0 0 H- 0 w 0 z 0 w Description 0 CN C� V u DN a 0 C/) -.1L cn 2 mb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARUNGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 9205 REGISTERS() �RCHI ECT Job Number Drawn By Appv'd By Sheet Title Sheet Number CHAE R. BLACK ATE OF WASHINGTON J LP DAR 080294 Plumbing Plans and Details P1 By GENERAL PLUMBING RESPONSIBILITIES THE GENERAL CONDITIONS OF THE CENERAL SPECIFICATIONS, ALONG WITH ALL APPLICABLE INSTRUCTIONS TO BIDDERS, SHALL FORM A PART OF THIS SECTION OF THE SPECIFICATIONS. REFERENCE IS MADE TO REQUISITES FOR BIDDERS AND CONTRACTORS UNDER OTHER SECTIONS OF THESE SPECIFICATIONS, WHICH SHALL BE CONSIDERED BINDING, UNLESS OTHERWISE NOTED, UNDER THIS SECTION. SCOPE - EACH CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED WITH THE CONSTRUCTION DETAILS BEFORE SUBMITTING BID. NO ALLOWANCES WILL BE MADE BECAUSE OF THE CONTRACTOR'S UNFAMILIARITY WITH THESE DETAILS. ALL PERFORMANCE OF CONSTRUCTION SHALL BE AS REQUIRED BY THE PACE OF THE GENERAL CONSTRUCTION. PROPOSALS ARE ACCEPTED WITH THE ASSUMPTION THAT CONTRACTOR IS FAMILIAR WITH JOBSITE CONDITIONS AND UTILITY LOCATIONS. THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. PERMITS ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE SUBCONTRACTOR INVOLVED. CODE REQUIREMENTS ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS AND OWNER'S INSTRUCTIONS, AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, OR REGULATIONS OF THE GOVERNING BODIES, WHETHER SO SHOWN OR NOT. ALL MODIFICATIONS REQUIRED BY SUCH AUTHORITIES SHALL BE MADE BY THE CONTRACTOR WITHOUT ANY ADDITIONAL COST TO THE OWNER. MATEtIAISANDWORKMANSHIP 1. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY THE MANUFACTURERS AND, UNLESS OTHERWISE SPECIFIED, SHALL BE NEW AND FREE FROM ANY DEFECTS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURE AND QUALITY UNLESS OTHERWISE SPECIFIED. 2. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY COMPETENT WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. WORK SHALL BE PROPERLY PROTECTED DURING CONSTRUCTION AND, UPON COMPLETION, THE INSTALLATION SHALL BE THOROUGHLY CLEANED AND ALL DEBRIS REMOVED FROM THE SITE. CODE AND REOl1lAT10NS EACH SUBCONTRACTOR SHALL COMPLY WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS BEARING ON THE CONDUCT OF THE WORK AS DRAWN OR SPECIFIED. IF A SUBCONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT A VARIANCE WITH SUCH CODES, HE /SHE SHALL PROMPTLY NOTIFY THE GENERAL CONTRACTOR AND THE TENANT IN WRITING. IF ANY SUBCONTRACTOR PERFORMS ANY WORK KNOWING IT TO BE CONTRARY TO LAWS, ORDINANCES, RULES AND REGULATIONS AND WITHOUT GIVING SUCH NOTICE, THE SUBCONTRACTOR SHALL BEAR ALL COSTS ARISING THEREFROM. PROTECTION OF WORK AND PROPERTY 1. EACH SUBCONTRACTOR SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS /HER WORK FROM DAMAGE AND SHALL PROTECT THE OWNER'S PROPERTY FROM INJURY OR LOSS ARISING FROM HIS /HER WORK. HE /SHE SHALL MAKE GOOD ANY SUCH DAMAGE, INJURY, OR LOSS, EXCEPT SUCH AS MAY BE DIRECTLY DUE TO CAUSES BEYOND HIS /HER CONTROL AND NOT TO HIS /HER FAULT OR NEGLIGENCE. HE /SHE SHALL ADEQUATELY PROTECT ADJACENT PROPERTY AS WELL. 2. EACH SUBCONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS FOR THE SAFETY OF THEIR EMPLOYEES ON THE JOB AND SHALL COMPLY WITH ALL PROVISIONS OF FEDERAL, STATE AND LOCAL BUILDING CODES AND SAFETY LAWS TO PREVENT ACCIDENTS OR INJURY TO PERSONS ON OR ADJACENT TO THE PREMISES WHERE THE WORK IS BEING PERFORMED. EACH SUBCONTRACTOR SHALL MAINTAIN ALL INSURANCE REQUIRED TO PROTECT HIMSELF /HERSELF, OWNER AND TENANT FOR THE DURATION OF THE WORK AGAINST PROPERTY DAMAGE AND PUBLIC LIABILITY. CHANGE N THE WORK THE TENANT, WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. COOPERATION ALL WORK UNDER THESE SPECIFICATIONS SHALL BE ACCOMPLISHED IN CONJUNCTION WITH OTHER CONTRACTORS AND TRADES OF THIS PROJECT IN A MANNER WHICH WILL ALLOW EACH CONTRACTOR AND TRADE ADEQUATE TIME AT THE PROPER STAGE OF TO FULFILL HIS /HER CONTRACTS. THE OWNER SHALL BE CONSULTED TO RESOLVE ANY QUESTIONS WHICH MIGHT ARISE BETWEEN TRADES AS TO THE PLACING OF LINES, DUCTS, CONDUITS, FIXTURES, OR EQUIPMENT, OR SHOULD IT APPEAR DESIRABLE TO REMOVE ANY GENERAL CONSTRUCTION WHICH WOULD AFFECT THE APPEARANCE OF STRENGTH OF THE STRUCTURE. SUBSTITUTION OFMATERIMS MANUFACTURER'S NAMES ARE LISTED HEREIN TO ESTABLISH A STANDARD. THE PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE, IF IN THE OPINION OF THE TENANT, THE SUBSTITUTE MATERIAL IS OF A QUALITY AS GOOD OR BETTER THAN THE MATERIAL SPECIFIED, AND WILL SERVE WITH EQUAL EFFICIENCY AND DEPENDABILITY, THE PURPOSE FOR WHICH THE ITEMS SPECIFIED WERE INTENDED. SHOP DRAWINGS SHOP DRAWINGS AND CATALOG DATA ON ALL MAJOR ITEMS OF EQUIPMENT AND SYSTEMS, AND SUCH OTHER ILLUSTRATIVE MATERIAL AS MAY BE CONSIDERED NECESSARY BY THE TENANT, SHALL BE SUBMITTED BY THE CONTRACTOR IN ADEQUATE TIME TO PREVENT DELAY AND CHANGES DURING CONSTRUCTION. DRAWINGS AND SPECFICATIONS 1. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL OR ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. 2. SHOULD THE CONTRACTOR DEEM IT NECESSARY TO MAKE CHANGES TO ITEMS SHOWN ON CONTRACT DRAWINGS, THE SHOP DRAWINGS, DESCRIPTIONS, AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE OWNER FOR APPROVAL. RESPONSBLITY THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE SATISFACTORY AND COMPLETE EXECUTION OF ALL WORK INCLUDED IN HIS CONTRACT. HE /SHE SHALL PRODUCE COMPLETE FINISHED OPERATING SYSTEMS AND PROVIDE ALL INCIDENTAL ITEMS REQUIRED AS PART OF HIS /HER WORK, REGARDLESS OF WHETHER SUCH ITEM IS PARTICULARLY SPECIFIED OR INDICATED. GUARANTEE ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIONAL AND ACCEPTANCE BY TENANT SHALL BE A CONDITION OF THIS CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL BE REPAIRED OR REPLACED BY THE SUB — CONTRACTOR WITHOUT ADDITIONAL CHARGE TO THE TENANT. MAMMALS 1. SANITARY SEWER — CAST IRON OR COPPER PIPING MAY BE USED EXCEPT THAT ALL PIPING BELOW GRADE SHALL BE CAST IRON. VENTS TWO INCHES (2 ") IN SIZE AND SMALLER MAY BE EITHER SCHEDULED 40 GALVANIZED STEEL OR COPPER PIPING. 2. DOMESTIC WATER AND HOT WATER PIPING SHALL BE TYPE "L" COPPER INSULATED WITH 1" ARMAFLEX OR EQUIVALENT. 3. GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL WITH SCREWED FITTINGS. 4. CHILLED WATER SUPPLY AND RETURN PIPING SHALL BE GALVANIZED STEEL PIPE (STANDARD WALL) OR TYPE "L" HARD COPPER TUBING. ALL PIPING SHALL BE INSULATED WITH 1" THICK OWENS CORNING FIBERGLASS 25 ASJ /SSL OR EQUAL. � � 1. SCREWED PIPE SHALL BE MADE UP WITH PIPE COMPOUND APPLIED TO THE MALE THREAD WITH NOT MORE THAN TWO THREADS LEFT EXPOSED PIPE SHALL B REAMED AFTER THREADING. 2. BELOW GRADE SANITARY PIPING SHALL BE CAST IRON PIPE AND SHALL BE OF THE HUB AND SPIGOT OR NO —HUB TYPE. INSTALLATION MUST MEET ALL PROVISIONS OF APPLICABLE CODE. ABOVE GRADE MAY BE PVC ONLY IF CODE AND LANDLORD E - EXISTING L - LANDLORD C - TENANT'S GENERAL CONTRACTOR T - TENANT K - KITCHEN EQUIPMENT CONTRACTOR V - TENANT VENDOR FURNISH I I llv1SNI RESPONSIBILITY NOTE' A PLUMBING A-1 WATER CLOSETS A A WATER CLOSETS — — B UNDERSLAB ROUGH —IN — — C FINAL CONN. & VENTS — — A LAVATORIES A LAVATORIES B UNDERSLAB ROUGH —IN — — C FINAL CONN. & VENTS — — A 3 MOP SINK A MOP SINK C C B UNDERSLAB ROUGH —IN C C ALLOW. 3 COPPER JOINTS SHALL BE MADE UP WITH 95 -5 SOLDER. (LEAD FREE) HANGERS AI HORIZONTAL PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED 10' -0" WITH SWIVEL SPLIT PIPE HANGERS EQUAL TO CRANE NO. 199E OR GRINNELL NO. 104. VERTICAL PIPING SHALL BE SUPPORTED BY MEANS OF WROUGHT IRON CLAMPS SUSPENDED FROM THE UNDERSIDE OF STRUCTURE WITH HANGER RODS. CLEANOUTS SHALL BE AS MANUFACTURED BY JOSAM, ZURN MFG. CO. OR EQUAL AND SHALL BE INSTALLED AT ALL BENDS, ANGLES, AND ENDS OF ALL WASTE AND SEWER LINES, AS CALLED FOR ON THE DRAWINGS, AND AS REQUIRED BY LOCAL CODES. ALL CLEANOUTS SHALL BE BROUGHT TO GRADE, AND IN ALL CASES, SHALL BE PROVIDED WITH SUFFICIENT SPACE FOR RODDING. VALVES ALL VALVES SHALL BE BRASS AND MANUFACTURED BY CRANE, NIBCO, STOCKHAM, LUNKENHEIMER, NORDSTROM, GRINNELL OR EQUAL. FOR SECOND LEVEL STORES, THE TENANT'S GENERAL CONTRACTOR SHALL RUN ALL LINES REQUIRED FOR PLUMBING ROUGH —INS TIGHT AGAINST THE UNDERSIDE OF THE SECOND FLOOR LEVEL. THE SECOND FLOOR STRUCTURAL SLAB SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS SHOWN ON THE PLANS. C FINAL CONN. & VENTS C C M FLOOR SINK A FLOOR DRAINS C C B UNDERSLAB ROUGH —IN C C C FINAL CONN. & VENTS C C CLEANOUTS A CLEANOUTS C C B UNDERSLAB ROUGH —IN C C C FINAL CONN. & VENTS C C A THREE COMPARTMENT SINK A THREE COMPARTMENT SINK V V B INDIRECT WASTE C C C FINAL CONNECTION C C A-7 ELECTRIC WATER HEATERS A ELECTRIC WATER HEATER V V B FINAL CONN. V V C INSULATION — HOT WATER LINE V V A HANDWASH SINK A HANDWASH SINK V V B INDIRECT WASTE C C C FINAL CONNECTION C C A.-9 MISCELLANEOUS A WATER METER DEPOSIT ONLY (IF REQUIRED) C C B TELE. SVC. TO /INCL PREMISES C C SPRINKLER SYSTEM C HOT WTR. SUP. & RET. PIPES & INSUL. — — D CONTROLS — CH. & HOT WTR. PIPING — — E ALL TAP FEES (IF REQ'D.) C C 1. SHOP DRAWINGS: THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE RATING BUREAU FOR THEIR APPROVAL. A COPY OF THE APPROVAL LETTER FROM THE RATING BUREAU SHALL BE FORWARDED TO THE TENANT AND TO THE LANDLORD. 2. SPRINKLER HEADS: SPRINKLER HEADS IN ENTRY AND SALES AREA SHALL BE CONCEALED TYPE WITH A WHITE CAP. STORAGE TOILET AND WORK AREAS WITH CEILINGS — BRASS PENDANT TYPE. STORAGE AND WORK AREAS WITHOUT CEILINGS — BRASS UPRIGHT TYPE. 3. ALL ADDITIONS TO OR MODIFACATIONS OF THE SPRINKLER SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13 AND LOCAL CODES. A-10 SPRINKLER SYSTEM A ENGINEERING — — B EQUIPMENT — — A GREASE TRAP A GREASE TRAP C C B UNDERSLAB ROUGH —IN C C C FINAL CONN. & VENTS C C RESPONSIBILITY NOTES 1. ROOF OPENINGS FOR PLUMBING AND RELATED WORK SHALL BE THE RESPONSIBILITY OF THE PLUMBING SUBCONTRACTOR. HE SHALL EMPLOY THE LANDLORD'S ROOFER FOR THIS WORK TO MAINTAIN THE ROOF BOND. 2. SANITARY SEWER AND DOMESTIC WATER, STUBBED INTO THE PREMISES BY THE LANDLORD. REFER TO SHEET P -1 FOR LOCATIONS. FIELD VERIFY LOCATIONS. 3 . THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE RATING BUREAU FOR APPROVAL. A COPY OF THE APPROVAL LETTER FROM THE RATING BUREAU SHALL BE FORWARDED TO THE TENANT AND LANDLORD AS LISTED ON SHEET T1. 4. THE TENANT'S GENERAL CONTRACTOR (T.G.C.) SHALL RUN PLUMBING LINES TIGHT TO THE SECOND FLOOR STRUCTURE. THE FLOOR SLAB SHALL BE CORED AS REQUIRED TO INSTALL SERVICE STUBS, FLOOR BOXES, ETC. 5 . IF DRAWINGS CALL FOR THE REUSE OF EXISTING EQUIPMENT, THE TENANT'S GENERAL CONTRACTOR SHALL VERIFY THAT ALL SUCH EQUIPMENT IS IN PROPER WORKING ORDER, OR TAKE THE NECESSARY STEPS TO ACCOMPLISH SUCH. IF REPLACEMENT IS REQUIRED, USE THE EQUIPMENT AND HARDWARE AS SPECIFIED ON THESE SCHEDULES OR AS CALLED OUT IN THE SPECIFICATIONS ON THIS SHEET. ALL SUCH ITEMS MUST MEET ALL GOVERNING CODES AND STANDARDS OF PRACTICE. V `�.i Ma ®,y -- "tila i fa I RECEIVE DEC 1 02000 PERMIT C NTEfI TEMPORARY SERVICES THE CONTRACTOR SHALLPROVME THE FOLLOVNG MIMIC arms OFTEMPORARY SERVICE: 1. TEMPORARY WATER R — E WATER REQUIRED IN THE PERFORMANCE OF THE CONTRACT SHALL BE PROVIDED AND PAID FOR BY THE CONTRACTOR. WATER USED FOR HUMAN CONSUMPTION SHALL CONFORM TO REQUIREMENTS OF STATE AND LOCAL AUTHORITIES FOR POTABLE WATER. 2 TEMPORARY HEAT — WHEN ,REQUIRED FOR PROPER INSTALLATION OR PROTECTION OF ANY PORTION OF THE WORK, THE CONTRACTOR SHALL FURNISH AND INSTALL TEMPORARY HEATING UNITS AS APPROVED BY THE LANDLORD OR LOCAL AUTHORITY. 3. COST OF LANDLORD PROVIDED UTILITY SERVICES — IF THE LANDLORD ELECTS TO PROVIDE TEMPORARY UTILITY SERVICES, THE CONTRACTOR WILL BE SO INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE PROVISIONS OR COORDINATE WITH LANDLORD'S GENERAL CONSTRUCTOR TO PAY THE COST OF SAID TEMPORARY CONSTRUCTION AND UTILITY SERVICES. NOTE FOR TENANT GHNBGIL CONTRACTOR: IT IS THE RESPONSIBILITY OF THE TENANTS GENERAL CONTRACTOR TO MAKE USE OF APPLICABLE NOTES & SPECIFICATIONS LISTED ON THIS SHEET AS THEY MAY PERTAIN TO THE SPECIFIC JOB. r s ....•�- A Date Description By A A A A A T.G.C. TO CORE DRILL SLAB AS INDICATED — LOCATION TO BE COOR— DINATED W /L.L.'S SITE REPRESENTATIVE. EXISTING SLAB. TOP OF STRUCTURE AT FIRST FLOOR. NEOPRENE SEAL CLEANOUT PLUG FINISHED FLOOR WATERPROOF MEMBRANE WATERPROOF SEALANT CONCRETE SLAB SEALANT FINISHED FLOOR CONCRETE SLAB TOP OF FIRST FLOOR STRUCTURE 3" CAST IRON DRAIN PIPE W/P —TRAP TO TENANT'S SANITARY SEWER. Penetration Detail SCALE: None O Clean Out Detail SCALE: None Floor Drain Detail SCALE: None 7 — LEMONADE TOWER ICE BIN FILL W /SEALANT CONTINUOUS, WATERTIGHT & FIREPROOF. SCHEDULE 40 GALV. PIPE SLEEVE - 2" MINIMUM ABOVE CONC. SLAB. PIPE OR CONDUIT. 4" CAST IRON PIPE TO TENANT'S SANITARY SEWER `.; ■�11111111111111111111111r .iA I ` j iii I■■ 1111 3/8" COPPER LINE TO TRAP PRIMER AIR GAP 10 GALLON REMOVABLE WASTE Ice Bin Section Detail ` `t J SCALE: None Q■ daorgn %BOO a This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Seal Job Number Drawn By Appv'd By 0 0 0 w 0 0 2 w J Sheet Number 10/14/08 Itt'6,SI .F EO ARCHITECT IVIIC IAL` -L R. BLACK STATE OF WASHINGTON JLP DAR 080294 Sheet Title Plumbing Specifications and Details PS1 la9 o/5 FRESH PRETZELS O EXISTING L = 1 A NDLORD DESCRIPTION 0 = OWNER NEW C = DONTRACTOR FURNISH BY INSTALL BY GENERAL L 0 C L 0 C BUILDING PERMIT BY TENANT (PICKED UP AND PAID FOR BY T.G.C.) e A PLAN CHECK FEES • A ALL OTHER PERMITS • INSPECTIONS AND INSURANCE • TEMPORARY POWER • • BARRICADE, IF REQUIRED • • CLEAN UP _.. �___ ✓,,,, �, CONCRETE SLAB ,...- • 0 0 CONCRETE SLAB WORK —SAW CUT SLAB & CORE DRILLING • • KIOSK . • • • KITCHEN EQUIPMENT (REFER TO KITCHEN EQUIPMENT SCHEDULE) • • MALL FLOORING 0 KIOSK AS REQUIRED 0 • 0 • ILLUMINATED KIOSK SIGN GENERAL CONTRACTOR TO COORDINATE INSTALLATION WITH VENDOR e II KIOSK ANCHORAGE TO FLOOR • • KIOSK INTERIOR /EXTERIOR TILE BASE • • PREZEL MOSAIC ON EXTERIOR OF KIOSK FACE(S) • • A Date Description By A A A A A [ROJECT TEAM WETZELS PRETZELS FRANCHISEE ' ARCHITECT: LANDLORD: PROJECT MANAGER: I BUILDING INFORMATION PROJECT ADDRESS: TENANT OCCUPANCY: NUMBER OF STORIES: APPUCABLE CODES: PROPOSED USE: KIOSK LEASE AREA: NUMBER OF EMPLOYEES (AT ONE TIME): EGRESS REQUIREMENTS: TOILETS REQUIRED: CIiAI CHAO 10821 RAINIER AVENUE SOUTH SEATTLE, WA 98178 TEL: (206) 228 -1498 MICHAEL R. BLACK 3100 E. RANDOL MILL RD. ARLINGTON, D( TEL: (817) 701 -4819 FAX: (817) 633 -4153 WESTFIELD, LLC 11601 WILSHIRE BLVD., 14TH FLOOR LOS ANGELES, CA 90025 ATTN: SUZANNE ESCABAR PHONE: (310) 689 -5643 LAURIE KEYS 11 WEWNGTON PLACE AUSO VI CA 92656 PHONE FAX (949)421501 1187 SOUTHCENTER MALL 633 SOUTHCENTER KIOSK SPACE #9240 SEATTLE, WA 98188 M, MERCANTILE LEVEL 2 OF 2 ABV ADJ AFF ACT A/C ALT ARCH BLKG BD BLDG CLR CLG CONC COL CMU CONST DTL DIAM DIM DR DWG DISP (E), EX EA EL, ELEV ELECT EQ EXT FES FF FT FR FLUOR FOF FOS FIN FRP FO GA GC GL GYP HORIZ INT INSUL MAX MECH MIN MTL (N) NTS 0/ O.C. O.S.C.I. PSI PLAM PLYWD R.C.P. SHT SIM SQ SS TBD TYP UBC UON UTR VIF WH BUILDING: 2006 INTERNATIONAL BUILDING CODE MECHANICAL 2006 INTERNATIONAL MECHANICAL CODE PLUMBING: 2006 INTERNATIONAL PLUMBING CODE ELECTRICAL: 2005 NATIONAL ELECTRICAL CODE FIRE: 2006 INTERNATIONAL FIRE CODE ENERGY: 2006 WA STATE ENERGY CODE FOOD RETAIL 180 SQUARE FEET 3 MAX. 1 REQUIRED, 1 PROVIDED PUBLIC RESTROOMS PROVIDED BY LANDLORD ABBREVIATIONS ABOVE ADJACENT ABOVE FINISHED FLOOR ACOUSTICAL CEIUNG TILE AIR CONDITIONING ALTERNATE ARCHTTECT(URAL) BLOCKING BOARD BUILDING CLEAR CEIUNG CONCRETE COLUMN CONCRETE MASONRY UNIT CONSTRUCTION DETAIL DIAMETER DIMENSION DOOR DRAWING DISPENSER EXISTING EACH ELEVATION ELECTRICAL EQUAL EXTERIOR FIXTURE EQUIPMENT SUPPUER FINISHED FLOOR FEET FLOOR FLUORESCENT FACE OF FINISH FACE OF STUD FINISHED) FIBERGLASS REINFORCED PANEL FACE OF GAUGE GENERAL CONTRACTOR GLAZING, GLASS GYPSUM HORIZONTAL INTERIOR INSULATION MAXIMUM MECHANICAL MINIMUM METAL NEW NOT IN CONTRACT NOT TO SCALE OVER ON CENTER OWNER SUPPUED/ CONTRACTOR INSTALLED POUNDS PER SQUARE INCH PLASTIC LAMINATE PLYWOOD REFLECTED CEIUNG PLAN SHEET SIMILAR SQUARE STAINLESS STEEL TO BE DETERMINED TYPICAL UNIFORM BUILDING CODE UNLESS OTHERWISE NOTED UP THROUGH ROOF VERIFY IN FIELD WATER HEATER ICY PLAN FRESH PRETZELS LEMONADE HOT DOGS VENDOR LIST KIOSK: EQUIPMENT: SCOPE SOUTHCENTER MALL SEATTLE, WA THE CARRIAGE WORKS, INC. 1877 MALLARD LANE KLAMATH FALLS, OR 97601 ATTN: DAN DAWSON PHONE: (541) 882 -0700 EDWARD DON & CO. 2500 S. HARLEM AVE. N. RIVERSIDE, IL 60546 ATTN: STEVE WISHON PHONE (800) 677 -4366 EXT. 8526 RECEIPT OF OWNER PROVIDED REMS NOTE: wee•: Pretzels / FRESH PRETZELS LEMONADE HOT DOGS KIOSK SPACE #9240 INSTALLATION OF U.L AND N.S.F. USTED KIOSK. UTILITIES TO KIOSK BY LANDLORD. FINAL CONNECTIONS BY G.C. G.C. SHALL PATCH /REPAIR MALL FLOORING AT NEW PLUMBING /ELECTRICAL WORK. ALL MATERIALS NOT PART OF PREFABRICATED KIOSK, SUPPUED /INSTALLED BY G.C. G.C. SHALL TURN —OVER FULLY OPERATIONAL KIOSK. ITEMS PROVIDED BY TENANT: THE TENANTS GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIPT AND SUBSEQUENT PROTECTION OF ALL ITEMS WHICH ARE FURNISHED BY TENANT AND ARE TO BE INSTALLED BY TENANT'S GENERAL CONTRACTOR. ITEMS PROVIDED BY TENANT WILL BE INDICATED ON THE EQUIPMENT RESPONSIBILITY SCHEDULE SHEET AND THE MECHANICAL AND ELECTRICAL SCHEDULE SHEET. IN AN EFFORT TO BETTER ASSIST YOU IN THE EVENT OF POSSIBLE FREIGHT DAMAGE, WE ARE REQUESTING THAT YOU DO THE FOLLOWING PRIOR TO SIGNING THE CARRIER'S PROOF OF DEUVERY. WITHOUT ANY NOTATION OF DAMAGES ON THIS DOCUMENT, WE CANNOT PURSUE THE CARRIER FOR REPLACEMENT AND /OR REPAIR COSTS FOR THE ITEM(S). IN THE EVENT THAT DAMAGES ARE NOT NOTED, EDWARD DON & COMPANY WILL NOT BE HELD UABLE FOR THESE ASSOCIATED COSTS. • INSPECT, THOROUGHLY, THE OUTER PACKAGING OF THE FOOD SERVICE EQUIPMENT PRIOR TO SIGNING THE CARRIER'S PROOF OF DELIVERY. • IF THERE IS VISIBLE DAMAGE TO THE PACKAGING, NOTE THE EXCEPTION, IN DETAIL, THE DAMAGE WHICH SHOULD INCLUDE THE MAKE, MODEL, AND QUANFTY. THERE SHOULD NEVER BE STATEMENTS WRITTEN SUCH AS "JUST A SCRATCH, OR DAMAGED BOX ". STATEMENTS LIKE THESE GIVES THE CARRIER JUSTIFICA1 ION FOR DENYING CLAIMS IF WE HAVE TO REPLACE OR REPAIR THE DAMAGED ITEM. • IF THE SHIPMENT IS LABELED AS "FRAGILE ", YOU HAVE THE RIGHT TO OPEN AND INSPECT THE CONTENTS BEFORE SIGNING THE CARRIER'S PROOF OF DEUVERY. THIS SHOULD ALWAYS BE THE CASE WHEN YOU ARE RECEIVING DISPLAY GLASS CASES. • APPARENT EXTREME DAMAGES TO FREIGHT SHOULD ALWAYS BE REFUSED. IF FREIGHT IS REFUSED, EDWARD DON & COMPANY SHOULD BE NOTIFIED IMMEDIATELY SO THAT WE CAN ENSURE THAT A REPLACEMENT IS SHIPPED. • DAMAGES TO TRUE SHIPMENTS SHOULD ALWAYS BE REFUSED. NOTIFY EDWARD DON & COMPANY AND A REPLACEMENT WILL BE SHIPPED. • IT IS IMPERATIVE THAT ALL FREIGHT BE OPENED WITHIN 15 DAYS OF DELIVERY. THIS IS THE CUT —OFF POINT FOR HUNG FREIGHT CLAIMS IN THE EVENT OF A CONCEALED DAMAGE ISSUE. AFTER THIS 15 DAY TIME PERIOD HAS LAPSED, WE HAVE NO RECOURSE IN FlUNG A FREIGHT CLAIM AGAINST THE CARRIER. EDWARD DON & COMPANY WILL NOT BE HELD UABLE IN THE EVENT THAT WE ARE NOT NOTIFIED OF CONCEALED DAMAGES WITHIN 15 DAYS OF THE DEUVERY. N VICINITY MAP i 161st 6t' DRAWING INDEX ARCHITECTURAL A0.1 RESPONSIBILTIIES, INDEX, AND BLDG. INFO A0.2 SPECIFICATIONS A0.3 SPECIFICATIONS A1.1 MALL KEY PLAN AND STORAGE PLAN KI.1 KIOSK DRAWINGS K1.2 KIOSK DRAWINGS K1.3 KIOSK DRAWINGS K1.4 KIOSK DRAWINGS ELECTRICAL El POWER PLAN AND UGHTING PLAN ES1 ELECTRICAL SPECIFICATIONS PLUMBING P1 PLUMBING PLANS AND DETAILS PS1 PLUMBING SPECIFICATIONS AND DETAILS RESPONSIBILITIES MMAaPOUE iG7 yz.;i a ti �i n — Y N IVlill�ili�lilillil II Vi pl I PO I�,�1 ggp . .r��r.:i rn 5 t St S 166th Ln 2448 MaRQus.-511nc. . 5 15.1.1 :et 17 APPLICANT COPY APPROVED SUBJECT TO ORDINANCE 3EA L - KIN Go � — 0epi o b Ic Health 51_ ti ok By )), - "4. , ° . NOV 2r 2008 ANE AGASI +i b'PECT1O B`v C .; . i " Y HEALTH D PRIG ANT PLAN - t CVILVV w rum CODE COMPLIANCE APPROVED DEC 1 7 2053 City Of Tukwila Bo L®J G_DIVISiQJ r11a11�k.IIIiIIIIcGi' IpnIIV �.00 m•. I eDO tt C. li4 f:k tar Baker Blasi Strander 8tvd L. Y resk ir R' Map data 7 ?446 NAV 74'lµr^d. -, ¢' 4.1414 n �. CITY NOV 2 5 2008 PERMIT CENTER N i p ds oo o roup 3100 East Randal Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions 0 0 H- 0 w 0 0 w rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Seal Drawn By Appy'd By Sheet Title Job Number Sheet Number Lui w a w 10/14/08 ds 080294 RER A0.1 U U HAEL R ATE OF WASHING ION Responsibilities, Drawing Index & Bldg. Info. FINISH SCHEDULE ROOM /AREA FLOOR BASE WALLS CEILING CEILING HEIGHT REMARKS REMARKS (E) MALL FLOORING REFER: KIOSK DRAWINGS REFER: KIOSK DRAWINGS OPEN OPEN TO MALL CEILING SEE KIOSK DRAWINGS 01 I KIOSK DIRECT WASTE EXISTING CONCRETE 4" RUBBER BASE PAINT EXISTING LAY —IN V.I.F. G.C. SHALL REPLACE BROKEN OR MISSING TILE PAINT: BENJAMIN MOORE (SEMI — GLOSS) COLOR BRILLIANT WHITE I 02 I REMOTE STORAGE 11_'-5 1 MK. DESCRIPTION SUPPLIER QTY. BASE REMARKS/ MANUFACTURER ELECTRICAL REQUIREMENTS PLUMBING REQUIREMENTS REMARKS VOLTS H.P. AMPS PHASE CONN CW HW FIN DIRECT WASTE INDIRECT wasrE Ot NOT USED ® NOT USED O METAL STORAGE LOCKER KEC/T 1 O4 SHELVING— 4 TIER HIGH KEC/T 3 SETS LEGS 18" DEEP X 4' —O" WIDE S.S. SHELV'G 5, i KEC /T 1 CASTERS TRUE T -23F SINGLE DOOR 115 1/2 9.5 1 C 15AMP CIRCUIT 6 1 v ozgagoaREEME o KEC /T 1 CASTERS TRUE T -23 115 1/3 7.5 1 C 15AMP CIRCUIT KITCHEN EQUIPMENT SUPPLIER TO PROVIDE CUT - SHEETS ON ALL SUPPLIED EQUIPMENT TO T.G.C. A Date Description By A A A A A WETZEL'S PRETZELS Remote Storage SPACE #52305C (E) Remote Storage Floor Plan Scale 1/4' =1'-0' 3 0"-4" 80sf 22' -1a" TERRACE TRASH 496sf 600 sf 41 SFC10 1233sf SFC9B Ct CO t KITCHEN EQUIPMENT SCHEDULE T TENANT / OWNER KEC KITCHEN EQUIPMENT CONTRACTOR TGC TENANTS GENERAL CONTRACTOR SUBJECT o ORDINANCE SE Dept By NOV 2 r 2O 19220 l•u St�rc� 3 (')f e Ili OVA 1 t t7" 1�nrol� C CHORD D DIRECT CONNECT Scale 1/4' =1 -0' G.C. SHALL CLEAN/ RE —LAMP EXISTING LIGHTS. VERIFY PROPER WORKING ORDER. EXISTING LAY —IN CEILING GRID AND ACCOUTICAL TILES TO REMAIN. G.C. SHALL REPLACE BROKEN, STAINED, OR DAMAGED TILES. (E) Remote Storage RCP Kiosk Space #9240 xt— u r .r,r u.r nr as a— _n y c r .4' JO. L,r r� ,l, Uo .n Ir r � 6 � �3 Second Level Mall Key Plan No5a6 I WETZEL'S PRETZELS ELEVATOR EXIT TO PAVING GARAGE I NOTE: G.C. TO CONFIRM EXACT PLACEMENT OF KIOSK W/ MALL MGMT. PRIOR TO START OF CONSTRUCTION. MALL PUBLIC RESTROOMS CODE COMPLIA IC ApP V l City Of Tukwila O at dezjan group 3100 East Rondo! Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f This document contains information proprietary to PDMS Design Group and is fumished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 Issue Date Revisions 1 N 3 Drawn By Appv'd By Sheet Title C') 0 0 0 w 0 0 2 w (int, MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 Seal M CHAR. R, @LACK ATE OF WASIiNGRtIN Job Number Mall Key Plan and Storage Plan Sheet Number 10/14/08 REGISTERF A CHI (E 080294 ds RER Al .l 0 CNA Q V m V v DN N V) 2 2 EQUIPMENT SCHEDULE Date • ITEM MODEL VOLTS AMPS COMMENTS A 1 PEPSI DISPENSER CORNELIUS IMPULSE I -6UF —I 120 2. NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 2 GOURMET ICE SYSTEM BUNN MD# ULTRA -2 120 22 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 ICE MAKER MANIIOWOC MD# QV-0274A 120 10 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I OWN BAKERS PRIDE MD# P44S 208 35.4 UL LISTED SUPPLIED AND INSTALLED BY OTHERS I OVEN CART MENU CO. #WPMOC NSF APPROVED SUPPLIED AND INSTALLED BY OTHERS I HAND SINK 15 X 15 304 STAINLESS STEEL WITH SOAP DISPENSER NSF APPROVED SEE PAGE I PLLIIDDI SUPPLIED BY CARRIAGE WORKS SCOPE OF WORK I' HOT WATER MACHINE BUNN MD# H5E— I6-120 120 15.4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 WATER HEATER A.O.SMITH ECJN -40 240 18.8 UL LISTED SEE PAGE 1 PLUMEIDr SUPPLIED BY CARRIAGE WORKS SCOPE OF WORK I 3 COMPARTMENT SINK ADVANCE TABCO MD# 94— K6—I80 SEE PAGE I PLUMBING NSF APPROVED RK SUPPLIED BY CARRIAGE WORKS SCOPE OF WO 4 24- DRYING RACK METRO WALL MOUNT SUPPLIED AND INSTALLED BY CARRIAGE WORKS I MOP SINK SUPPLIED AND INSTALLED BY OTHERS 1 MIXER HOBART MD# HL200 120 8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS I MIXER CART SEEYI.E CRAFTSMEN CO. #WPMOC NSF APPROVED SUPPLIED AND INSTALLED BY OTHERS ° MICROWAVEk`I AMANA COMMIERIAL PRODUCTS MD# RCS IODA 120 13.8 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS tto *AREFRIGERA BEVERAGE —AIR MD# UCR27 -3 115 4 NSF APPROVED AND UL LISTED SUPPLIED AND INSTALLED BY OTHERS HEATED DISPLAY -al WITH I ADDITIONAL WIRE RAC( A. J. ANTUNES & CO. ROUNDUP MD# DCH -320 I I5 I5 ETL LISTED SUPPLIED AND INSTALLED BY OTHERS 1 JET SPRAY CORNELIUS MD# EJ I —A8651 I 15 5 NSF APPROVED AND UL LISTED SUPPLIED AHD INSTALLED BY OTHERS 4 LIGHT BOX EOGELIT LIGHT BOX 22- X 28' 115 2 SUPPLIED MID INSTALLED BY CARRIAGE WORKS A Date Description By A RECESSED LIGHTING IN BEAM LIGHT BOX A A 1 I _ LLLI_I_ L L LI_ LLLL LL L— LLLLL _LLLLLLLL_LLLLLLLLLLLLLL _LL_LLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLL LLLLLLLL _LLLLLLLLLLLLLLLLLLLLLL 1 A Date Description By A A A A A TOP OF WALLS, INSIDE WALLS, AND ALL CABINETS ARE WILSONART #10776 -60 KENSINGTON MAPLE FROSTED GLASS WITH WETZEL'S PRETZELS CLEAR ETCHED TILE DONE BY OTHERS LED LIGHTING ABOVE 8" KICK LLLLLLLL LLLLLLLL LLLLLLLL LL LLLL LL LLLLL L LLLLLL L LLLLLL LIGHT B _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLLLLLLLLLLLLLLLLL _LLLLLLLL�LLLLLLLLLLLLLLL _LLLLLLLL LLLLLLLLLLLLLL ° TILE DONE BY OTHERS LED LIGHTING ABOVE 8" KICK _LL _LLL _LLL _LLL _LLL _LLL _LLL 1 RECESSED LIGHTING IN BEAM CHEMETAL #927 LIGHT STAINLESS zz WETZEL'S PRETZELS MAN SIGNAGE GLASS WITH VINYL BACKING (SEMI GLOSS) VIVA GOLD IGHT BOX LIGHT BOX CHEMETAL #927 LIGHT STAINLESS DOOR IS CHEMETAL #927 LIGHT STAINLESS -- LED LIGHTING LETTERS ARE SINTRA BLUE ABOVE 8" KICK WITH SINTRA BRIGHT YELLOW BACK \WETZEL'S PRETZELS / GROUND GLASS WITH VINYL BACKING SEMI GLOSS VIVA GOLD CLEAR GLASS WETZEL'S PRETZEL FROSTED ETCHED TRIM IS CORIAN LINEN DENJAMIN MOORE 2020 -50 MELLOW YELLOW PAINTED WITH GLASS COVER INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S3619T (B &W WHITE TILES) DONE BY G.C. WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED VISION / ISSUE NO DA1E PROJECT NAME WESTFIELD SOUTHCENTER FINISH CALLOUT I The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. BE A D A VISED THAT THE NEW WASHINGTON STATE FOOD CODE REQUIRES COMMERCIAL REFRIGERATION TO HOLD FOOD AT 41 DEGREES FAHRENHEIT OR BELOW !!! (DOWN FROM 45 DEGREES) / • DRAINBOARDS, UTENSIL RACKS, OR TABLES LARGE ENOUGH TO , ACCOMMODATE ALL SOILED AND CLEANED ITEMS SHALL BE PROVIDED FOR NECESSARY UTENSIL HOLDING ...BEFORE CLEANING AND AFTER SANITIZING. SWING DOORS SIGNAGE PEPSI DISPENSER GOURMET ICE SYSTEM JET SPRAY The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this document does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. / CA/RiA 3E SERVICE D ERVICE OPERATION AREA FLOORS, O FLOOR COVERINGS, WALLS, WALL COVERINGS, AND CEILINGS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED SO THEY ARE SMOOTH, DURABLE AND EASILY CLEANABLE. WAREWASHING /DISHWASHING SINK COMPARTMENTS SHALL BE LARGE ENOUGH TO ACCOMMODATE IMMERSION OF THE LARGEST EQUIPMENT AND UTENSILS. —GOURMET ICE SYSTEM PAPER TOWEL HOLDER UNDER COUNTER WATER HEATER ICE MAKER IHEATED L`,DISPLAY / —PEPSI BOX RACK SPACE Opt CART' 0 CAkk7A SE / /OAKS INC, FOOD, FOOD O PREPARATION AND FOOD SERVICE EQUIPMENT STORAGE AREAS ARE PROHIBITED UNDER SEWER LINES THAT ARE NOT SHIELDED TO INTERCEPT POTENTIAL DRIPS. - --DNDER COU.( ER ■ REERIGER,EIQB, 1 5" X I 5" HAND SINK WITH SOAP DISPENSER IIOT WATER MACHINE L_ UNDER COUNTER MICROWAVE / /OAKS I / 1877 Mallard Ln. Klamath Falls, Oregon (541) 882 -0700 Food equipment hat is certified for sanitation by an American Standards Institute (ANSI) - accredited certfication program will comply with ' the food code equipment& utensil material ' construction and design requirements. HOT WATER GENERATION AND DISTRIBUTION SYSTEMS SHALL BE SUFFICIENT TO MEET THE PEAK HOT WATER DEMANDS THROUGHOUT THE FOOD ESTABLISHMENT. PLUMBING SYSTEMS SHALL BE DESIGNED, CONSTRUCTED AND INSTALLED ACCORDING TO LAW (APPLICABLE LOCAL, STATE, AND FEDERAL STATUES, REGULATIONS AND ORDINANCES) • SIGNAGE 4 24" WIRE DRYING SHELVES WALL MOUNT RACKS ON WALL ABOVE SINK IXER ON A CART MOP SINK DROP SHELF 1877 Mallard Ln. Klamath Falls, Oregon `541) 882 -0700 IOX18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 8 DRAWN BY– V BRUHN . C LOCKERS OR OTHER SUITABLE FACILITIES SHALL BE PROVIDED FOR THE ORDERLY STORAGE OF EMPLOYEES' CLOTHING AND OTHER POSSESSIONS. RESTROOM & KITCHEN HAND WASH SINKS SHALL BE EQUIPPED TO PROVIDE WATER AT A TEMPERATURE I OF AT LEAST 100 DEGREES FAHRENHEIT THROUGH A MIXING VALVE OR COMBINATION FAUCET. SELF CLOSING OR METERING FAUCETS SHALL PROVIDE A FLOW OF WATER FOR AT LEAST 15 SECONDS. •ETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED EQUIPMENT J i TISION / ISSUE NO DATE PROJECT NAME WESTFIELD SOUTHCENTER 10X18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 10 DRAWN BY– V BRUHN 2 APPROVED SUBJECT TO ORDINANCE N 2 Z(E DIAN A;" ID - (lu2-• s1Z lC`1o1�3' NO CHANGES SHALL BE MADE WITHOUT HEALTH DEPARTMENT APPROVAL BACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD LIGHT BOX BACK PAINTE GLASS SHERWI WILLIAM SEMI GLOS VIVA GOL BACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD CORIAN LINEN LIGHT BOX The data in this document incorporates proprietary rights of The Carriage Works, Inc.. Any party accepting this Jocument does so in confidence and agrees that it shall not be duplicated in whole or in part, nor disclosed to others without the consent of The Carriage Works, Inc.. The data in this document incorporates proprietary The Carriage Works, Inc.. Any party accepting this does so in confidence and agrees that it shall not in whole or in part, nor disclosed to others without of The Carriage Works, Inc.. LED LIGHTING ABOVE 8" KICK WETZEL'S PRETZEL SIGNAGE COVERING ELECT. DOOR / CHEMETAL #927 WETZEL'S PRETZELS MURAL LIGHT STAINLESS LED LIGHTING ABOVE 8" KICK PE i0`1OH BY .t r ld rights of document be duplicated the consent / I GfiKl'llt6E /V0P1(_5 INC, FINAL NOTES APPROVED BY PROJECT NAME WESTFIELD SOUTHCENTER SHEET CAJR/A SE //o INC1 ACK PAINTED GLASS SHERWIN WILLIAMS SEMI GLOSS VIVA GOLD CHEMETAL # 927 LIGHT STAINLESS TILE DONE BY OTHERS �1 877 Mallard Ln. Klamath Falls, Oregon (541) 882 -0700 1 l877 Mallard Ln. Klamath Falls, Oregon 97601 / (541) 882 -0700 LIGHT BOX 10 X 18 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE I I DRAWN BY– V BRUHN INSIDE BASE OF KIOSK IS CERTIFIED 6 "HIGH SLIMFOOT TILE COVE BASE, CERAMIC TOPSET S3619T (B &W WHITE TILES) DONE BY G.C. WETZEL'S MALL FINAL NOTES APPROVED BY UL & NSF LISTED REVISION / ISSUE NO DALE PROJECT NAME WESTFIELD SOUTHCENTER FINISH CALLOUT 2 IOXI8 KIOSK WETZEL'S PRETZELS 10 -09 -08 PAGE 9 DRAWN BY– V BRUHN J c 6 i gtg6 1 1 %- itike Pmp DEG i P1 on JA—DING DIVISION mot u pd TS eo Qn a © This document contains information proprietary to PDMS Design Group and is furnished in confidence for the limited purpose of evaluation, bidding, review, or construction. This document or its contents may not be used for any other purpose and may not be reproduced or disclosed to others without the prior written consent of PDMS Design Group Project Address Wetsel's Pretzels Southcenter 633 Southcenter Kiosk Space #9240 Seattle, WA 98188 .1 Issue Date 10/14/08 Revisions 1 rrrb MICHAEL R. BLACK, AIA 3100 E. RANDOL MILL ARLINGTON, TEXAS 76011 817.701.4819 WASHINGTON REGISTRATION NO.: 9205 REGISTERED ARCHITECT IV1C HAIL R. BLACK Si ATE OF 'WASHINGTON Job Number Drawn By App /d By Sheet Title 3100 East Randol Mill Road Arlington, Texas 76011 817.633.4200 p o 817.633.4153 f V) C`3 0 0 0 w 0 Z 0 w J Sheet Number (010 080294 ds RER Kiosk Drawings K1.3