Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D08-509 - ANDREW'S SPACE - OFFICE PHASE II
ANDREW'S SPACE 3415 S 116 ST D08 -509 Parcel No.: 1023049043 Address: 3415 S 116 ST TUKW Suite No: Tenant: Name: ANDREW'S SPACE Address: 3415 S 116 ST , TUKWILA WA Owner: Name: TTA/E PROPERTY TAX DEPT 207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Phone: 206 433 -8997 Contractor: Name: PRECISION BUILDERS INC Address: PO BOX 98609 , DES MOINES WA 98198 -0609 Phone: 206 878 -2948 Contractor License No: PRECIBI151C2 doc: IBC -10/06 CitAbf Tukwila • DEVELOPMENT PERMIT DESCRIPTION OF WORK: PHASE II: INSTALLING NEW OFFICE TENANT IMPROVEMENTS WITH INTERIOR NON - BEARING PARTITIONS AND SUSPENDED ACOUSTICAL CEILING. Value of Construction: $23,500.00 Fees Collected: $803.93 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: * * continued on next page ** Permit Number: D08 -509 Issue Date: 12/17/2008 Permit Expires On: 06/15/2009 Expiration Date: 01/19/2010 D08 -509 Printed: 12 -17 -2008 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 4 Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D08 -509 Issue Date: 12/17/2008 Permit Expires On: 06/15/2009 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: doc: IBC -10/06 Date: ‘12 D O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: I2 7 `" G.9 Print Name: I (gh�c..' t l This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -509 Printed: 12 -17 -2008 Parcel No.: 1023049043 Address: 3415 S 116 ST TUKW Suite No: Tenant: ANDREW'S SPACE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -509 Status: ISSUED Applied Date: 12/03/2008 Issue Date: 12/17/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila doc: Cond -10/06 D08 -509 Printed: 12 -17 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(Office areas) 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3- 2.1)(Warehouse areas) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the doc: Cond -10/06 D08 -509 Printed: 12 -17 -2008 nearest visible exit sign. (IFC 1011.1) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 31: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 32: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 33: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 34: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinlder work shall commence without approved drawings. (City Ordinance #2050) 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) doc: Cond -10/06 D08 -509 Printed: 12 -17 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 41: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 42: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 43: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * * continued on next page ** D08 -509 Printed: 12 -17 -2008 i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: '- d ( --- Date: / L — /7-e Y Print Name: J- i Zh�t. J . /fi doc: Cond -10/06 D08 -509 ordinances governing or local laws regulating Printed: 12 -17 -2008 SITE LOCATION 1 "` ' I 1 L ,� I' King Co Assessor's Tax No.: /OA 8049 0 #3 Site Address: 3445 - J(��i I h 410 ��/' e �� Suite Number: /d)J Floor: Tenant Name: Andrews Spa °, - Ph aSc.Ti»o Property Owners Name: Q � F Mailing Address: I X1-1 4 ii (6? Etat,t' )A state 9811,6 City CONTACT PERSON - who do we contact when your permit is ready to be issued Name: LQ V i d 7 'eh l Q, 1910 nav- bri r t 6 W d IhehluA,rch, wrn Mailing Address: E-Mail Address: CITY OF TUKWIt Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print** GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: - qq t d ALAI/ i � A'rch i k I d- Mailing Address: / "1 / �D 6t0/1 t i l �1�i V J W Contact Person: 101 E -Mail Address: d V P.h I P,To d ,on-) Company Name: Mailing Address: Building Permit No. _ PO I> _ 71 Mechanical Permit No Plumbing/Gas Permit No. • , Public Works Permit' • Project No. r: . (For o,�"zce use only) - -- - -- _ Day Telephone: to 0 I - k egg City Fax Number: ..Sect tat WA g 8 J I [o City State /- Zip Day Telephone: �lOCO - '7"33 - S 9 Fax Number: dot" - A4-4.0 - 83(01 ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record City Contact Person: E -Mail Address: Fax Number: QMpplicetionsWocros- Applications On Line\3 -2006 - Permit Applivation.doc Revised: 9-2006 bh New Tenant: ❑ Yes WA . 9 8 , II l' State Zip State State Zip zip 0 Day Telephone: Page 1 of 6 BUILDING PERMIT INFO TION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ !/ /f . OD Existing Building Valuation: $ Scope of Work (please provide detailed information): Tn &htLki T Lt) 4-enQi in(Qrn(l emo,,n 5 W14-h inttrior non - bea/ i a,r Iz h o (LS 6 e.n a!e tL ac Gt.Sk, c_>✓i l �n 9 �' Will there be new rack storage? ❑ Yes. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None Q:'Applications\Fotms- Applications On Lino3-2006 - Permit Application.doc Revised: 9 -2006 bh Handicap: Other (specify) Will there He storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l Floor l 1, 000 I,'4-1 V B 4-51 2 Floor 3 Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFO TION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ !/ /f . OD Existing Building Valuation: $ Scope of Work (please provide detailed information): Tn &htLki T Lt) 4-enQi in(Qrn(l emo,,n 5 W14-h inttrior non - bea/ i a,r Iz h o (LS 6 e.n a!e tL ac Gt.Sk, c_>✓i l �n 9 �' Will there be new rack storage? ❑ Yes. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None Q:'Applications\Fotms- Applications On Lino3-2006 - Permit Application.doc Revised: 9 -2006 bh Handicap: Other (specify) Will there He storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x II " paper including quantities and Material Safe ata Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Date Application Accepted: Signature: ,,L / I,, 1 Print Name: t/"/ U e 16 Mailing Address: on l�,er GENT: Drive. 31N Date: /A- x,-08 Day Telephone: c O (D • � '.3 -8 .SP.att t l.()A . 93 the City State Zip Date Application Expires: TX2io'hlo.61 Q:\Apphe ons\Fons- Apphemons On rnneO -2006 - Pant Apph®tion.doc Revised: 9 -2006 bh Page 6 of 6 Receipt No.: R08 - 03946 Initials: WER User ID: 1655 Payee: PRECISION BUILDERS ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 1023049043 Permit Number: D08 -509 Address: 3415 S 116 ST TUKW Status: APPROVED Suite No: Applied Date: 12/03/2008 Applicant: ANDREW'S SPACE Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21790 489.00 Account Code Current Pmts 000/322.100 484.50 000/386.904 4.50 Total: $489.00 Payment Amount: $489.00 Payment Date: 12/17/2008 08:38 AM Balance: $0.00 0606 12/17 9707 TOTAL 489.00 doc: Receiot -06 Printed: 12 -17 -2008 Parcel No.: 1023049043 Address: 3415 S 116 ST TUKW Suite No: Applicant: ANDREW'S SPACE Receipt No.: R08 -03859 Payee: DAVID E. KEHLE ARCHITECT ACCOUNT ITEM LIST: Description don. Ranaint -f16 PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Payment Check 18467 314.93 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Initials: JEM Payment Date: 12/03/2008 12:00 PM User ID: 1165 Balance: $489.00 Account Code Current Pmts 000/345.830 314.93 Total: $314.93 Permit Number: D08 - 509 Status: PENDING Applied Date: 12/03/2008 Issue Date: Payment Amount: $314.93 0133 12/03 9707 TOTAL 314.93 Printart 19- f13-9lf1R Project: #2N( /Yeu5 SPIT Type of Inspection: ri ,ti I/ l Address: 3z/(5 s // G „9 „9 Date Called: Special Instructions: Date me 7 p.m. Requester: Phone No: ,20 -�C( / 3 () INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION P^' - V 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 70 COMMENTS: Wy-01; - /(4-714,Weok;), / pa 60 0 REINSPECTION EE RE UIRED. Prior to inspection, fee must be at 6300 Southcenter Blvd /Suite 100. Call to schedule reinspection. Re Eeipt No.: 'Date: Approved per applicable codes. Corrections required prior to approval Project: r _ AA ( re � .3 5 f Type of Inspection: F�Aeo A . (, , Address: � c / / j Y� h l to -17 12a J r e Called: 'Special Instructions: Date Wanted: ` Requester: Phone N 3 / �1 �Q (p -�S INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: / „' 7 C7 C_A L c L{ 1i-_ Inspector :( Date: 2 — ( - Q El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project i iifw.- Type of Insp ction: �P,/ $ .. x7. ,,��f?' Addr ss: ``� -. '//._.! //G, S "f Date Called: Special Instr,6 j Date Wanted: .. p.m. Requester: Phone No: INS ECTION NO. INSPECTION RECORD Retain a copy with permit /) PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: i 0 ds0 REINSPECT ON FEE REQUIRE . Prior to inspection, fee ust be Id at 6300 Sout center Blvd., Suit 100. Call to schedule reinspection. Receipt No.: !Date: Projea f?/W / /fW5 -�If9 Type of Inspection: <1/5/cA/A M/ Date Called: d Address: 5 S _ //Z .-5--, Special Instructions: Date Wanted: et ( �r p.m. Riquester: Phone No '39, /33' 14 Approved per applicable codes. Corrections required prior to approval. COMMENTS: aye; Sx/5�1r,.dJ /. �-".4 /� pr v-.61 & s_ti. el' -7' _Jo a-, : i - e i i 4'h N ,.......-Th \ INSPECTION RECORD '1 Retain a copy with permit / f8 t- 5— Si INSPE ION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0.00 REINSPECTIO FEE REQUI ° ED. Prior to inspection, fee must be aid at 6300 Southce ter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: 1 ANkOkre. 4 c Srk( e Type of Inspection: li 1 • sus .� Ce,� i Address: 3415 S ) J7Date Called:P Special Instructions: 0 2 3 Date Wanted: / a.m. / - 22 — a1 `- p " Requester: Phone No: / `3 7 (0— /30 Inspec INSPECTION NO. Approved per applicable codes. COMMENTS: r: INSPECTION RECORD Retain a copy with permit pair PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 2- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. k J 1 (i ) r'Jt- .se(. JC.kei Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: Ar _w s f ,�-e_ Type o`0 11 -il -A f � , ,� ...� -, ` � f1�t � o A Addr s: I5 S. III° — ` Date Called: /^ Special Instructions: S u ' 1V 1 2 Z / . Date Wanted: q -di ��� p.m. Requester: Phone No: 1 J —15-25 INSPECTION RECORD r Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspecto Date: tir -01 ❑ $60.00 REINSPECTION FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Sdite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: AlQC SPA Type of Inspection: 0p e., Address : 3 S ► 1 (o src Date Called: Special Instructions: Date Wanted: I v _ U p.m. Requester: Phone No: .2.0 6 - 3C C - 1 _ 5 INSPECTION RECORD Retain a copy with permit b O o `" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 COIW1rTS: 0.00 REINS ECTION FEE aid at 6300 Southcenter Bl r eceipt No.: Date . Prior to inspection, fee must be 100. Call to schedule reinspection. Date: Approved per applicable codes. El Corrections required prior to approval. Project: A IA Cif .' t...i Spar c Type of Inspection: \J /e/lit1' eicy i.,41.44--, Address: 3115" Suite #: J J/t Sr Contact Person: Pre-Fire: Special Instructions: Occupancy Type: Phone No.: .20‘ • .W6 . ./C- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: . • ' • „ Ui INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT #06),P- So 7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Approved per applicable codes. Corrections required prior to approval. COMMENTS: I 1 • t j .0 ir 0; OP • F.. •,f ; '4 I Y y 7 1 I 1 t 1 . -i- /- i f • •- roe Inspector: Date: z.-10r Hrs.: / $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: Nt 5 S Ai. e Type of Inspection: L Address: 241/5" ' Suite #: )3 z S )11 Contact Person: Special Instructions: Occupancy Type: - Phone No.: 6- 3i &V 1530 Needs Shift Inspection: - Sprinklers: - _ Fire Alarm: Hood & Duct: Monitor: - --- - - - - -- -- Pre -Fire: Permits: Occupancy Type: - INSPECTION NUMBER INSPECTION .RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 S APproved per applicable codes. n Corrections required prior to approval. COMMENTS: ‘1 • F Inspector: Date: 2/g47. r Hrs.. \ 0:00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Project: 4o 5 e pc o6 Tye of Inspection: Address: 1)M t 4 h • 1W' I P Suite #: h.1 Contact Person: (, a (;.,rk Special Instructions: Phone No.: Needs Shift I n spection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: i `�ti2 , lci.'. - 'hi �w '�a�+..- �.._ +e,...,s• _..-e s .- .. r.a� •:.serts^¢e'�t *a+..)r�Tt FS 'Y•�v,,+�.F"�- 5'- !^Nti';HS?.+m. ':`1.:, fi?4.^.SS::a..,,,.+3ivf:`i��F.w irh.x ..." -'.Y3v e++si -M- �.� -. <- �+.Aia- .il.i: .. sv��, 3+ k" Y^ �nFSai ..ea +as!�- •caa;t:.r].�1'�.4 a INSPECTION NUMBER . INSPECTION RECORD Retain acopy with permit Word /Inspection Record Form.Doc Approved per applicable codes. CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 PERMIT NUMBERS 444 And over Park East, Tukwila,Wa. 98188 206 -575 -4407 I I Corrections required prior to approval. COMMENTS: Inspector: • dA 15 11 • Date: � /07 Mrs:: r $8 0 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. tY P P T.F.D. Form F.P. 113 Project: -A ki bit "f4 Q 66 Type of Inspection: Address: 3%415 5 . Suite #: 12:5 I t ( sT Contact Person CA c chet)t,. Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: • ----------- - - - - - -- Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ti I INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andov r Park East, Tukwila, Wa. 98188 206 -575 -4407 I - 1 Approved applicable codes. INSPECTION RECORD . Retain a copy with permit Date: ii3/ Dee - 't; PERMIT NUMBERS ...VI required prior to approval. COMMENTS: • Att.a v,-r o A t - nA-c cot) 8 prweA. Lt tai `' . Inspector:,,,,, is it. $ REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Hrs.: 4ord /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Location (floor /room no.) Occupancy Description Allowed Watts per ft " Area in ft Allowed x Area I/ 1 a Z Mil* 1 Ifo I o i - From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1. **0 Location _ (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 1 - 1 r 2 1t Vb ritWItc. isle[ c 5-y 1 14 lP i I citv1tvvw rut( COMPLIANCE CODE CEIVED F ThKWLA APPROVED CIT s DEC 0 CENTER DEC 11 2093 PERT Of Tukwila DING DIVISION Total Prop ay no exceed Total wed Watts for Interior Total Proposed Watts [� tet—ti w s Interior Lighting Summary 2008 Washington State Nonresidential Energy Code Compliance Forms Project Info Project Address ;19 Project Description 2006 Washington State Nonresidential Energy Code Compliance Form Applicant Name: ' I V ` � Et j � Applicant Address: , 1 .o4e 142,3 ( Applicant Phone: ' - 4-,3 - A61q: ) Maximum Allowed Lighting Wattage Proposed Lighting Wattage Date iy For Building Department Use Revised July 2007 ❑ New Building ❑ Addition P Alteretipn. ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning retwire t'ierrts::.;,,, Compliance Option Prescriptive ( Lighting Power Allowance 0 Systems 'Analysis" • (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. PO Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) . 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments', restaurants/bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'` 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Cleary indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elect tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms -1 Unit Lighting Power Allo ( LPA 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Lighting, Motor,; and *Transfor,mer 2006 Washington State Nonresidential Energy Code Compliance Forms Permit Plans Checklist ' LTG -CHK Revised July 2007 Project Address � �' (Date le Il/J of 1 necessary to check a permit application for compliance with the lighting, motor, and transformer Nonresidential Energy Code. B requirements The following information is in the 2006 Washington State Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) II/ 1513.1 Local controVaccess Schedule with type, indicate locations -T 1513.2 Area controls Maximum limit per switch -,, 1 f_I 4 � 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) I 1514 IMax. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) 1 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture a n 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, Completed ballasts, watts per fixture MOTORS (Section 1511) MIA I 1511 lElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I 1 TRANSFORMERS (Section 1540) 11' A I 1540 'Transformers 'Indicate size and efficiency I I 2006 Washin• on State Nonresidential Ener• Code Compliance Form If "no" is circled for any question, provide explanation: Project Info Project Address 4 # 1�y, Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing / / 11 X 100 = �( Date j7 .� f l� O yes Check here if using this option and if project meets all requirements for the Concrete/Masonry no Option. See Decision i Flowchart (over) for qualifications. Enter requirements for each qualifying assembly 0..3 - • For Buuul 01:12)(2k. c ing Department Use FIL �� Applicant Name: r�AY � / • , /+v� -tl 1 Applicant Address: 1 A 0 ; , *a � v `' r l u M , W6' i i' it fl a �_ �__� Applicant Phone - 4'33 e�1� Space Heat Type 0 Electric resistance AA All other (see over for definitions) Glazing Area Calculation Note: Below grade walls may be included in the Gross Exterior Wall Area if they are insulated to the level required for opaque walls. Total Glazing Area Electronic version: these values are automatically taken from ENV -UA -1. (rough opening) Gross Exterior (vertical & overhd) divided by Wall Area times 100 equals % Glazing / / 11 X 100 = �( Concrete/Masonry Option O yes Check here if using this option and if project meets all requirements for the Concrete/Masonry no Option. See Decision i Flowchart (over) for qualifications. Enter requirements for each qualifying assembly O yes Check here if using semi- heated path and if project meets all requirements for semi- heated spaces Semi-Heated Path as defined in section 1310. Requires other fuel heating and qualifying thermostat Only wall At no insulation requirement is reduced (2006 change). Only available in prescriptive path. 2006 Washington State Nonresidential Energy Code Compliance Form En ;Climate Zone;1 EN -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Envelope Requirements (enter values as applicable) Minimum Insulation R- values Roofs Over Attic All Other Roofs Opaque Walls' Below Grade Walls Floors Over Unconditioned Space Slabs -on -Grade Radiant Floors Opaque Doors Vertical Glazing Overhead Glazing Maximum U- factors 1 ��1✓4O Maximum SHGC (or SC) Vertical/Overhead Glazing 1. Assemblies with metal framing must comply with overall U- factors Notes: ❑ New Building ❑ Addition IgrAlteratibn ❑.Charige of Use Revised July 2007 Project Description Compliance Option 1:1 Component Performance ee Decision Flowchart (over) for qualifications) ❑ Seattle EnvStd ❑ Systems Analysis Opaque Concrete /Masonry Wall Requirements Wall Maximum U -factor is 0.15 (R5.7 continuous ins) CMU block walls with insulated cores comply If project qualifies for Concrete/Masonry Option, list walls with HC >_ 9.0 Btu /ft'•°F below (other walls must meet Opaque Wall requirements). Use descriptions and values from Table 10 -9 in the Code. Wall Description (including ir� a tio R - value & position) U- factor J. 008 Envelope Summary . (back) Climate Zone 1 •ENV - 2006 Washington State Nonresidential Energy Code Compliance Forms Decision Flowchart for Prescriptive Option Use this flowchart to determine if project qualifies for the optional Prescriptive Option. If not, either the Component Performance or Systems Analysis Options must be used. 1302 Space Heat Type: For the purpose of determining building envelope requirements, the following two categories comprise all space heating types: Other. AN other space heating systems including gas, solid fuel, oil, and propane space heating systems and those systems listed in the exception to electric resistance. (continued at right) 4--N No] All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door Yes AG Mass Wall Insulation Req. Mass Wall CMU Block Wood Frame Metal Framed U0.15 /R5.7ci Ins. Cores R19 R19 r , 2006 Washington State Nonresidential Energy Code Compliance Form R -10 R -19 R -30 R -21 R -19 R -10 R -10 U -0.60 es Glazing Vert OH Area % UVaI UVaI SHGC 0-30% 0.55 0.70 0.45 30-45% 0.45 0.60 0.40 >45% Not Allowed No w Glazing Criteria Met? Glazing Area % 0 -30% >30 Prescriptive Path Allowed Component Performance, Systems Analysis, or EnvStd Required Electric Resistance: Space heating systems which use electric resistance elements as the primary heating system including baseboard, radiant, and forced air units where the total electric resistance haat capacity exceeds 1.0 W/ft of the gross conditioned floor area. Exception: Heat pumps and terminal electric resistance heating in variable air volume distribution systems. Yes Glazing Cnteria Met? Yes fJ Yes V All Insulation Installed? Below Grd Wall (ext) Below Grd Wall (oth) Roof Over Attic All Other Roof Raised Floor Slab -On -Grade Radiant Floor Opaque Door Wood R -10 R -19 R -38 R -30 R -30 R -10 R -10 U -0.60 Metal R -10 U -0.062 U -0.031 U -0.034 U -0.029 R -10 R -10 U -0,60 Ye Yes— Vert OH UVal UVaI SHGC 0.40 0.60 0.40 Not Allowed No Yes Concrete/Masonry Option* Assembly Description Wall Heat Capacity (HC) Assy.Tag HC" Totals Area (sf) Area weighted HC: divide total of (HC x area) by Total Area HC x Area N Revised July 2007 No-► • AG Mass Wall Insulation Req. Mass Wall U0.15 /R5.7ci CMU Block Ins. Cores Wood Frame R19 Metal Framed U0.062 if the area weighted heat capacity (HC) of the total above grade wall is a minimum of 9.0, the Concrete Masonry Option may be used. For framed walls, assume HC =1.0 unless calculations are provided; for all other walls, use Section 1009. Building Permit Plans Checklist 2008 Washington State Nonresidential Energy Code Compliance Forms ENV -CHK Revised July 2007 Project Address :1 i t7s L ,, IDat i l The following information is necessary to check a building permit application for compliance with the building envelope requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes GENERAL REQUIREMENTS (Sections 1301 -1314) 1301 Scope Unconditioned spaces identified on plans if allowed LII 1302 Space heat type: If "Other", indicate on plans that electric resistance heat is not allowed - j ' 1��1r ` 13102 Semi- heated spaces Semi - heated spaces identified on plans if allowed 1311 Insulation t t ,/ 1311.1 Instil. installation Indicate densities and c l e a r a n c e s "1 i 1 J 1311.2 Roof /ceiling insul. Indicate R -value on roof sections for attics and other roofs; Indicate clearances for attic insulation; Indicate baffles if eave vents installed; Indicate face stapling of faced batts s-- t " ill 1311.3 Wall insulation Indicate R -value on wall sections; Indicate face stapling of faced batts; Indicate above grade exterior insulation is protected; Indicate loose -fill core insulation for masonry walls as necess; Indicate heat capacity of masonry walls if masonry option is used F73; 1311.4 Floor insulation Indicate R -value on floor sections; Indicate substantial contact with surface; Indicate supports not more than 24" o.c.; Indicate that insulation does not block airflow through foundation vents 1311.5 Slab-on -grade floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 24" from top: Indicate above grade exterior insulation is protected 1311.6 Radiant floor Indicate R -value on wall section or foundation detail; Indicate slab insulation extends down vertically 36" from the top; Indicate above grade exterior insulation is protected; Indicate insulation also under entire slab where req'd. by Official V 1312 Glazing and doors Provide calculation of glazing area (including both vertical vertical and overhead) as percent of gross wall area 13121 U -factors Indicate glazing and door U- factors on glazing and door schedule (provide area - weighted calculations as necessary); Indicate if values are NFRC or default, if values are default then specify frame type, glazing layers, gapwidth, low-e coatings, gas fillings I - f C ` e � 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing schedule (provide area - weighted calculations as necessary) 1313 Moisture control kl/ 1313.1 Vapor retarders Indicate vapor retarders on warm side ,' . 1 tIl ) 1� 1313.2 Roof /ceiling vap.ret Indicate vapor retarder on roof section; Indicate yap. retard. with sealed seams for non -wood struc. f ` 1313.3 Wall vapor retarder Indicate vapor retarder on wal. section t— l 1313.4 Floor vapor retarder Indicate vapor retarder on floor section I► l( � '`� 1313.5 Crawl space vap. ret Indicate six mil black polyethylene overlapped 12" on ground 1314 Air leakage 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasr eting, and weatherstripping �'1 1314.2 Glazing/door sealing Indicate weatherstripping 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing 1314.4 Recessed Lighting Fixtun Indicate IC rating, ASTM E283 :xrtification, and gasketing or caulking to ceiling PRESCRIPTIVE/COMPONENT PERFORMANCE (Sections 1320 -23 or 1330-34) Y Provide Envelope Sum. Form Completed and attached. component performar+ce worksheet if necessary If "no" Id shown for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washin ton State Nonresidential Ener Code Com.liance Form Building Permit Plans Checklist ' ENV -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Envelope - General Requirement 1311 Insulation 1311.1 Installation Requirements: All insulation materials shall be installed according to the manufacturer's instructions to achieve proper densities, maintain clearances and maintain uniform R- values. To the maximum extent possible, insulation shall extend over the full component area to the intended R- value. 1311.2 Roof /Ceiling Insulation: Open -blown or poured loose -fill insulation may be used in attic spaces where the slope of the ceiling is not more than 3/12 and there is at least 30 inches of clear distance from the top of the bottom chord of the truss or ceiling joist to the underside of the sheathing at the roof ridge. When eave vents are installed, baffling of the vent openings shall be provided so as to deflect the incoming air above the surface of the insulation. Where lighting fixtures are recessed into a suspended or exposed grid ceiling, the roof /ceiling assembly shall be insulated in a location other than directly on the suspended ceiling. EXCEPTION: Type IC rated recessed lighting fixtures. Where installed in wood framing, faced batt insulation shall be face stapled. 1311.3 Wall Insulation: Exterior wall cavities isolated during framing shall be fully insulated to the levels of the surrounding wails. When installed in wood framing, faced batt insulation shall be face stapled. Above grade exterior insulation shall be protected. 1311.4 Floor Insulation: Floor insulation shall be installed in a permanent manner in substantial contact with the surface being insulated. Insulation supports shall be installed so spacing is not more than 24 inches on center. Installed insulation shall not block the airflow through foundation vents. 1311.5 Slab -On -Grade Floor: Slab -on -grade insulation installed inside the foundation wall shall extend downward from the top of the slab a minimum distance of 24 inches or to the top of the footing, whichever is less. Insulation installed outside the foundation shall extend downward a minimum of 24 inches or to the frost line, whichever is greater. Above grade insulation shall be protected. EXCEPTION: For monolithic slabs, the insulation shall extend downward from the top of the slab to the bottom of the footing. 1311.6 Radiant Floors (on or below grade): Slab -on- grade insulation shall extend downward from the top of the slab a minimum distance of 36 inches or downward to the top of the footing and horizontal for an aggregate of not less than 36 inches. If required by the building official where soil conditions warrant such insulation, the entire area of a radiant floor shall be thermally isolated from the soil. Where a soil gas control system is provided below the radiant floor, which results in increased convective flow below the radiant floor, the radiant floor shall be thermally isolated from the sub - floor gravel layer. 1312 Glazing and Doors 1312.1 Standard Procedure for Determination of Glazing and Door U- Factors: U- factors for glazing and doors shall be determined, certified and labeled in accordance with Standard RS -31 by a certified independent agency licensed by the National Fenestration Rating Council (NFRC). Compliance shall be based on the Residential or the Nonresidential Model Size. Product samples used for U- factor determinations shall be production line units or representative of units as purchased by the consumer or contractor. Unlabeled glazing and doors shall be assigned the default U- factor in Table 10-6. 1312.2 Solar Heat Gain Coefficient and Shading Coefficient: Solar Heat Gain Coefficient (SHGC), shall be determined, certified and labeled in accordance with the National Fenestration Rating Council (NFRC) Standard by a certified, independent agency, licensed by the NFRC. EXCEPTION: Shading coefficients (SC) shall be an acceptable alternate for compliance with solar heat gain coefficient requirements. Shading coefficients for glazing shall be taken from Chapter 31 of Standard RS -1 or from the manufacturer's test data 1313 Moisture Control 1313.1 Vapor Retarders: Vapor retarders shall be installed on the warm side (in winter) of insulation as required by this section. EXCEPTION: Vapor retarder installed with not more than 1/3 of the nominal R -value between it and the conditioned space. 1313.2 Roof /Ceiling Assemblies: Roof /ceiling assemblies where the ventilation space above the insulation is less than an average of 12 inches shall be provided with a vapor retarder. (For enclosed attics and enclosed rafter spaces, see Section 1203.2 of the International Building Code.) Roof /ceiling assemblies without a vented airspace, allowed only where neither the roof deck nor the roof structure are made of wood, shall provide a continuous vapor retarder with taped seams. EXCEPTION: Vapor retarders need not be provided where all of the insulation is installed between the roof membrane and the structural roof deck. 1313.3 Walls: Walls separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.4 Floors: Floors separating conditioned space from unconditioned space shall be provided with a vapor retarder. 1313.5 Crawlspaces: A ground cover of six mil (0.006 inch thick) black polyethylene or approved equal shall be laid over the ground within crawispaces. The ground cover shall be overlapped 12 inches minimum at the joints and shall extend to the foundation wall. EXCEPTION: The ground cover may be omitted in crawl spaces if the crawlspace has a concrete slab floor with a minimum thickness of 3-1/2 inches. 1314 Air Leakage 1314.1 Building Envelope: The requirements of this section shall apply to building elements separating conditioned from unconditioned spaces. Exterior joints around windows and door frames, openings between walls and foundation, between walls and roof and wall panels; openings at penetrations of utility services through walls, floors and roofs; and all other openings in the building envelope shall be sealed, caulked, gasketed or weatherstripped to limit air leakage. 1314.2 Glazing and Doors: Doors and operable glazing separating conditioned from unconditioned space shall be weatherstripped. Fixed windows shall be tight fitting with glass retained by stops with sealant or caulking all around. EXCEPTION: Openings that are required to be fire resistant. 1314.3 Building Assemblies Used as Ducts or Plenums: Building assemblies used as ducts or plenums shall be sealed, caulked and gasketed to limit air leakage. 1314.4 Recessed Lighting Fixtures: When installed in the building envelope, recessed lighting fixtures shall by Type IC rated, and certified under ASTM E283 to have no more than 2.0 cfm air movement from the conditioned space to the ceiling cavity. The lighting fixture shall be tested at 75 Pascals or 1.57 Ibs/ft pressure difference and have a label attached, showing compliance with this test method. Recessed lighting fixtures shall be installed with a gasket or caulk between the fixture and ceiling to prevent air leakage. ACTIVITY NUMBER: D08 -509 DATE: 12 -03 -08 PROJECT NAME: ANDREW'S SPACE SITE ADDRESS: 3415 S 116 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: u 11-6-0D Builds ion X] Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: • PLAN REVIEW /ROUTING SLIP Structural Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documems/roming slip.doc 2 -28 -02 II I 0v 1/ 04.3e, Prevention Incomplete n • 0 1 tit IZ.--D brt Planning Division ❑ Permit Coordinator n DUE DATE: 12-04-08 DATE: Not Applicable DUE DATE: 01-01-09 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: • � F •�� �.. �'.�lfi.' � •� rte �• ..�.�s ;;F:... Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 DEVELOPERS INS CO 415171C 01 /19/2002 Until Cancelled Date Date $12,000.00 01/14/2002 3 DEVELOPERS SURETY It INDEM CO 415171C 01/19/1998 01/19/2002 $6,000.00 08/08/2001 2 DEVELOPERS INS CO 415171C 01/19/199601/19 /1998 $6,000.00 1 AMERICAN STATES INS CO EX516759 01/19/1985 01/19/1996 $6,000.00 Name Company Policy Effective Expiration Cancel Impaired Received Insurance Name Number Date Date Date Date Amount Date Name Role Effective Date Expiration Date SANBURN, SCOT D AGENT 02/22/1985 Untitled Page General /Specialty Contractor A business registered as a construction contractor with L£tI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company PRECISION BUILDERS INC 2068782948 PO BOX 98609 DES MOINES WA 981980609 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 600553713 ACTIVE PRECIBI151C2 CONSTRUCTION CONTRACTOR 2/22/1985 1/19/2010 PRECIB *163BR WESTCBI133M3 GENERAL UNUSED Business Owner Information Bond Information Insurance Information • • Page 1 of 2 https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= PRECIBI151 C2 12/17/2008 VICINITY MAC N.T.S. IOW SITE M4F N.T.S. ENERGY CODE NOTES I) NEAT IS VIA GAS, NO ELECTRIC NEAT ALLOWED -NO CHANGE TO ENVELOPE 2) PROVIDE VAPOR ON ALL IUALL TO THE WARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING WEATHER- STRIPPING AT ALL EXTERIOR DOORS. 4) MAXIMUM ALLOWABLE LOAD FOR SWITCH IS 80% OF 20 AMP CIRCUIT. 5) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR WINDOWS BUILDINCz 8 517E STATISTICS TAX PARCEL NUMBER: BUILDING CODE: TENENT AREA: CONSTRUCTION: OCCUPANCY GROUP: ZONE: AREA OF WORK: - BUILDING AREA TOTAL BUILDING AREA= 21,150 S.F. - TENANT AREA AFTER IMPROVEMENTS: SUITE 123 OFFICE: WAREHOUSE= MANUF. TOTAL= 11,000 S.F. - OCCUPANT LOAD: SUITE 123 OFFICE: WAREHOUSE MANE TOTAL: SCOPE OF WORK (PHASE TWO): 1023049043 2006 IBC W/ WA STATE AMENDMENTS SUITE 123 11,00 SF. V - FULLY SPRINKLED RED OFFICE± S -1 FOR. C /LI (COMMERCIAL / LIGHT INDUSTRIAL) 1,441 S.F. 2,980 SF. 5,664 SF. 2,356 S.F. 2,980 SF. /100= 29 OCC. (2 EXIT- TRAVEL DISTANCE) 5,664 S.F. / 500: 11 (1 EXIT) 2,356 SF. /200= 12 (1 EXIT) INSTALLING NEW OFFICE TENANT IMPROVMENTS W/ INTERIOR NON - BEARING PARTITIONS, AND SUSP. ACOUSTIC CEILING LEGAL DESCRIPTION 102304 43 LOT 2 OF CITY OF TUKWILA SHORT PLAT NO 90 -2 -SS RECORDING NO 9003121482 SD SHORT PLAT DAF FOR OF GOV LOT 3 & OF SE 1/4 OF NE 1/4 OF SEC 09 -23 -04 TGW PM OF GOV LOT 6 & OF SW 1/4 OF NW 1/4 OF SECTION 10 -23 -04 - BAAP 70 FT RGT OF ENGR STA H 556 +57.3 BEING A PT ON NELY MGN SHEET 1 OF 7 FOR R/W SR 99 S 118TH ST TO JUNCTION SSH NO 1 -K APPROVED JULY 23, 1957 SD PT BEING PT OF TANGENCY OF CURVE THRU POINT BEARING N 42 -02 -03 E 748,51 FT TH SELY ALG SD MGN & SAID CURVE THRU C/A OF 04 -26 -56 ARC DISTANCE OF 58.12 FT TH N 41 -57 -30 E 49981 FT TH N 15 -27 -21 E 75.56 FT TO PUB TH S 74 -32 -39 E 212,89 FT TH S 78 -39 -54 E 128.28 FT TH S 81 -20 -44 E 447.24 FT TAP OF CURVE CONCAVE TO N TH ELY ALG SD CURVE RAD OF 170 FT THRU C/A OF 15 -51 -28 ARC DIST OF 47,05 FT TH N 82 -47 -48 E 101.13 FT TO WLY MGN OF FOR OF SECTION 9 CONDEMNED IN SUPERIOR COURT CAUSE NO 646697 TH S 07 544,81 FT ALONG WESTERLY MARGIN TO A LN 60 FT N OF & PLW ENGR B -LINE AS SHOWN ON SHEET 1 OF 7 FOR R/W SR 99 SOUTH 118TH ST TO JUNCTION SSH 1 -K APPROVED JULY 23, 1957 TH N 88 -10 -42 W 630,87 FT TAP 60 FT RGT OF ENGR STA B 548 +00 SAID R/W PLANS TH N 79 -41 -19 W 359,21 FT TAP 70 FT RGT OF ENGR STA H 551 +64.4 SD PT ALSO BEING PT OF CUVE CONCAVE TO NORTH RAD PT BEARING N 10 -18 -41 E 748.51 FT TH NWLY ALG SD CURVE THRU C/A OF 30 -03 -04 ARC DISTANCE OF 392.59 FT TH N 41 -57 -30 E 499.81 FT TH N 15 -27 -21 E 75.56 FT TO POD REQUIRED FOR: Mechanical in Electrical lumbin Gas Piping City of Tukwila CUI, DIVISIODIVISION 44'�S L r W C Permit No. Plat review approval is subject to crioT3 Y n�1 ,n c , r3. / of construction documdocument dog the violation of any adopted code or orc n n o, Rcc ,t o{ approved Field Cop and conditions is acka° ovA ? cl: City of Tukwila BUILDING DIVISION 51 OCCUPANTS CODE COMPLIANCE APPROVE DEC 11 2 t �pf Tu('i N � EVlsic� nls No changes shall made to the scope of work without prior approval of Tukwila Building in . of NOTE: Revisions will require Drew plan submitt al and may include additional plan revi fees. SEPARATE PERMIT � RECEIVED CITY OF TUKWMLA DEC 0.3 2UUU PERMIT CENTER CO9 � rn rnco o o 000 to I I ro co ro N c0 c0 N w 0 1< rZ u- \ \WKST - 4 \Documents \CAD \1987- 1989 \8734- 5\ANDREWS SPACE SUITE 123 \CD'S PHASE TWO \SD- 1,T- 1,T- 2.dwg, 12/1/2008 10:27:48 AM, DesignJet 500 MAIN.pc3 C) SID-1 LENS FI ROOM AGE 0 I I 0 3TROOM LEGEND • EXIT 0 0 EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE CF CEILING EX. STEEL STUD WALL, BLOW IN SOUND INSULATION CAULK AT BASE, PURR WALL INSIDE EXISTING WALL OR DOOR TO 13E REMOVED. NEW DOOR EXISTING DOOR FOUR -FLEX OUTLET DUPLEX OUTLET WALL TELEPHONE OUTLET, MUDRING, CONDUIT AND PULL STRING ONLY. 24' -2i" 0 i 1' -b 24' -b" INTEGRATION ROOM • TRAVEL D IST. UNDER 100 L.F. 24' -b" 1 EXIT ► =1 E EXISTING N NEW DEDICATED $ SWITCH EX, OFFICES NO CHANGES MCC RM. A DATA OUTLET QJ J -BOX FOR POWER AND /OR PHONE ILLUMINATED EXIT SIGN 15' -0" v v DIMENSIONS ARE APPROXIMATE, VERIFY IN FEILD FLOOR PLAN SCALE I /8 " ■ 1' REV 11-13-08 2' X 4' NEW OR RELOCATED 3 -TU13E FLUORESCENT,PARABOLIC ELCTRONIC BALLAST 2' X 4' NEW OR RELOCATED 2 -TUBE FLUORESCENT 2' X 4' EXISTING 3 -TUBE FLUORESCENT TO REMAIN WAREHOUSE TESTING 24' -b" EXIT 0 0 24'-0" / I 11 LIGHTING CALCULATIONS NEW SPACE 1,550 OF X Im WOE = 1,550 WATTS ALLOWED NEW 2X4 - 11 X S8 WATTS = I,496 WATTS INSTALLED NOTE NEW ROOMS TO NAVE NEW SWITCHING PER ROOM MAX. 80% OF 20 AMP CIRCUIT PER SWITCH BUILDING ENVELOPE, ENTIRE SPACE IS HEATED AND COOLED USED PERSCRIPTIVE ON NEW SPACES ROOM SCHEDULE 1 FLOOR: EXISTING EXPOSED CONCRETE SEALED BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW GYP. BD. PAINT, +9 -6" FLOOR: NEW VCT BASE: NEW RUBBER BASE WALL: NEW GYP. BD. PAINT CEILING: NEW SUSPENDED ACOUSTICAL CEILING AT +9'-6" AFF WITH R -30 INSULATION NS ROOM 0 'R I 1 EXIT 0 A FLAT STUD WALL BRACNG FROM TOPS OF WALL, 8' oc TYR. OBL STUD BRACE FULL HEIGHT FLAT STUD WALL BRACNG FROM TOPS OF WALL, 8' OC TYP. EXP. TO STRUCTURE ABOvE v v / DBLSTUD BRACE PU� HEIGHT 1. 2. El 1. MODIFY SWITCHING A5 REQ'D WALL TYPES 6" X 20 GA. STEEL STUD © 24" O.C. TO +12' AFF WITH 5/8" GYP. BD. EACH SIDE W/ R -19 INSULATION FULL HEIGHT W/ VAPOR BARRIER OF WARM SIDE. (BRACE AS REQUIRED). 3 5/8" X 20 GA STEEL STUD @ 24" O.C. TO +9'- 6"'AFF WITH %' GYB. BD. , EACH SIDE. DOOR SCHEDULE (MATCH EXISTING) (LEVER HANDLE ON NEW DOORS) ( RE -USE EXISTING IF POSSIBLE) Ex. DOORS, NO CHANGES NEW 3' -0" X 7' -0" S.C. WOOD (STAINED) WITH TIMELY METAL JAMBS, 1 1/2 PAIR BUTTS, LOCKSET, SILENCERS, WALL STOP 2. PAIR OF 3' -0" X 7' -0" S.C. WOOD DOORS WITH TIMELY METAL JAMBS, LOCKSET, CLOSER, COOORDINATOR, 3 POINT LOCK SYSTEM, THRESHOLD, WEATHERSTRIP. EXISTING SUSP. ACOUSTIC CEILING NO CHANGES v v SCALE Ya" = 1' W -- - - 1 I 1 NEW GYP. BD CEILING ON b "X 20 GA STEEL JOISTS AT 24" O.C. W/ R -30 INSULATION EXIT A 0 x K :Vit.VV CODE COMPLIANCE APPROVED DEC 11 2008 City Of Tukwila BUILP1 . ,T DIVISION X08 - sd � A A EFLECTED CEILING • RECEIVED CITY OF TUKWILA DEC. 0 3 2008 PERMIT CENTER N O )) a) 10 GO c0 I I r7 c0 .4 c0 c0 N N TYP. FLAT STUD BRACING HORIZ. AT 8' O.C. E W V1 _ � W 1 c o z a+ A :a V1 rn c 1-1E-4 A Nz o rn 4-1 cY) C Ems+ 0 6.. \ \WKST -4 \Documents \CAD \1987 -1989 \8734 5\ANDREWS SPACE SUITE 123 \CD'S PHASE TWO \SD- 1,T- 1,T- 2.dwg, 12/1/2008 10:28:50 AM, DesignJet 500 MAIN.pc3 5/8" GYP. ED. BOYN SIDES STEEL STUDS r DETAIL: DOOR JAM13 SPACER BAR OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART WALL TYPE ONE 414 EX. ROOF STRUCTURE WITH R -11 INSULATION FLAT STUD WALL BRACE BEYOND TYP. POWDER DRIVEN PIN ANCHORED WALL TRACK, NILTI OR APPROVED, I" EMBEDMENT, 0.131 "DIA. �4'I,MIN AT UN- ATTACHED WALLS MN. 2" UALL ANGLE NOTE: ATTACH CEILING MD GRID TO WALL ANGLE (MOULDING) AT TWO ADJACENT WALLS VIA POP RIVETS. 4 12 GA. WIRES WITHIN 2" OF CROSS TEE CONNECTION ARRANGED AT 90' FROM EACH OTHER AND AT M ANGLE NOT EXCEEDING 45'. LOCATE RESTRAINT PANELS AT 12' O.C. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. SUS'''. CEILING UV R -30 CROSS - SECTION NOTES: I) MAIN BEAMS TEES AND CROSS TEES MUST BE HEAVY DUTY W/ CONNECTION STRENGTHS OF 100 POUNDS IN COMPRESSION 4 TENSION. 2) CEILING AREAS GREATER THAN 1000 SF MUST HAVE LATERAL FORCE BRACING VIA DIAGONAL SPLAY WIRES, LIMITING MOVEMENT TO LESS THAN 1/4" AT POINT OF ATTACHMENT. RESTRAINED CEILING DETAILS (MEETS IBC 2003 SEC 1621 AND CISCA 3 -4 ASTM C635 ASTM C636 ASCE 1 -02) i •I• �$ i P e 3 AIR GAP t t ' j 4' L IG 4T F I PROTECTION SCALE 1 . 2 . 2 . 2.2.2• :•2.2.2.2.2.1.2.2.202.2.2 0 . 0. 0. 0•0•0•0•0•0•044•2•2•2•2•2•50 0.1• :WA•MMA•MAIdek ,_-_•_•_•_-_-_•_•_-_•_•_•---•-Nraij•-•-•-•-•-•-•-•-•-•-•-•-• WIRES TO ROOF STRUCTURE ABOVE NOT SHOUJN FOR CLARITY EX. CONC. SLAB INTEGRATION ROOM NOTE: SUSPENSION WIRES TO BE 12 GAGE AT 4' O.C. WI ATTACHMENT DEVICES CAPABLE OF SUPPORTING 100 POUNDS. HANGER 4 PERIMETER WIRES MUST BE PLUMB WITHIN I IN b UNLESS COUNTER SLOPING WIRES ARE PROVIDED INSULATION 1/2" GYP. BD. OR CEILING TILES BRACED OR STRAPPED TOGETHER TO PROVIDE AIR TIGHT ENCLOSURE W /INSULATION ABOVE - STEEL STUD FRAMING AS REQUIRED PRISMATIC LENSED FLUORESCENT FIXTURE FOR RECESSED LIGHTS IN AN INSULATED SUSPENDED CEILINGS 3) LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO MAIN AND CROSS TEES. AND IF OVER 56! MUST BE INDEPENDENTLY SUPPORTED. 4) PARTITIONS GREATER T14416' TALL NEED INDEPENDENT BRACING VIA SPLAY WIRES (SEPARATE FROM ANY OTHER WIRES). PARTITIONS 6' OR LESS NO ATTACHMENT IS REQUIRED. 5) SPRINKLER HEAD PENETRATIONS MUST HAVE 2" OVERSIZED TRIM TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS. 6) MANUFACTURER CERTIFICATION OF COMPONENT PERFORIANCE AND PERIODIC SPECIAL INSPECTION OF ANCHOR SYSTEM IS REQUIRED. 1) FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL HEIGHT WALL PARTITION NAT BREAKS THE CEILING SHALL BE PROVIDED. 8) ALL CROSS TEES SHALL BE CAPABLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO Y OF ITS SPAN. 9) ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 INCH. SECTION b08 5 0 ? Rb E C COD OMPLIANCE APPROVED DEC 11 2008 City Of Tukwila BumoN5 DIVISION WALL + 9' -6" AFF W/ INSULATION GYP BD CEILING W/ R -30 INSULATION EX. OFFICE RECEIV CITY OF TU LA DEC, 0: 3`2008 PERMIT CENTER N CD rn� COCO re) c0 N 0 0 N N LU z o Q a_ L_ 0 \ \WKST -4 \Documents \CAD \1987- 1989 \8734- 5\ANDREWS SPACE SUITE 123 \CD'S PHASE TWO \SD- 1,T- 1,T- 2.dwg, 12/1/2008 10:29 :04 AM, DesignJet 500 MAIN.pc3 �nr wsa »• NEW TENANT IMPROVEMENT AT GATEWAY NORTH - - F` .: 1 - ' . . 1 ; r .: ' L E I r, i fAViD E. KEHLE PROJECT 5134 -5 DRAWN BY DAVE I 80 - 5Z - 6O 31v0 CHECKED BY DAVE 31`d0 DESCRIPTION offll ESVI 40 m3IA3Z1 NO 1 I I { ornl 35'dHd .i11.1N3d NO4 £I1.19fl 3140 �80 -1-11 8O-to-ZI LjIAS 5/8" GYP. ED. BOYN SIDES STEEL STUDS r DETAIL: DOOR JAM13 SPACER BAR OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING APART WALL TYPE ONE 414 EX. ROOF STRUCTURE WITH R -11 INSULATION FLAT STUD WALL BRACE BEYOND TYP. POWDER DRIVEN PIN ANCHORED WALL TRACK, NILTI OR APPROVED, I" EMBEDMENT, 0.131 "DIA. �4'I,MIN AT UN- ATTACHED WALLS MN. 2" UALL ANGLE NOTE: ATTACH CEILING MD GRID TO WALL ANGLE (MOULDING) AT TWO ADJACENT WALLS VIA POP RIVETS. 4 12 GA. WIRES WITHIN 2" OF CROSS TEE CONNECTION ARRANGED AT 90' FROM EACH OTHER AND AT M ANGLE NOT EXCEEDING 45'. LOCATE RESTRAINT PANELS AT 12' O.C. IN EACH DIRECTION AND WITHIN 6' OF EACH WALL. SUS'''. CEILING UV R -30 CROSS - SECTION NOTES: I) MAIN BEAMS TEES AND CROSS TEES MUST BE HEAVY DUTY W/ CONNECTION STRENGTHS OF 100 POUNDS IN COMPRESSION 4 TENSION. 2) CEILING AREAS GREATER THAN 1000 SF MUST HAVE LATERAL FORCE BRACING VIA DIAGONAL SPLAY WIRES, LIMITING MOVEMENT TO LESS THAN 1/4" AT POINT OF ATTACHMENT. RESTRAINED CEILING DETAILS (MEETS IBC 2003 SEC 1621 AND CISCA 3 -4 ASTM C635 ASTM C636 ASCE 1 -02) i •I• �$ i P e 3 AIR GAP t t ' j 4' L IG 4T F I PROTECTION SCALE 1 . 2 . 2 . 2.2.2• :•2.2.2.2.2.1.2.2.202.2.2 0 . 0. 0. 0•0•0•0•0•0•044•2•2•2•2•2•50 0.1• :WA•MMA•MAIdek ,_-_•_•_•_-_-_•_•_-_•_•_•---•-Nraij•-•-•-•-•-•-•-•-•-•-•-•-• WIRES TO ROOF STRUCTURE ABOVE NOT SHOUJN FOR CLARITY EX. CONC. SLAB INTEGRATION ROOM NOTE: SUSPENSION WIRES TO BE 12 GAGE AT 4' O.C. WI ATTACHMENT DEVICES CAPABLE OF SUPPORTING 100 POUNDS. HANGER 4 PERIMETER WIRES MUST BE PLUMB WITHIN I IN b UNLESS COUNTER SLOPING WIRES ARE PROVIDED INSULATION 1/2" GYP. BD. OR CEILING TILES BRACED OR STRAPPED TOGETHER TO PROVIDE AIR TIGHT ENCLOSURE W /INSULATION ABOVE - STEEL STUD FRAMING AS REQUIRED PRISMATIC LENSED FLUORESCENT FIXTURE FOR RECESSED LIGHTS IN AN INSULATED SUSPENDED CEILINGS 3) LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO MAIN AND CROSS TEES. AND IF OVER 56! MUST BE INDEPENDENTLY SUPPORTED. 4) PARTITIONS GREATER T14416' TALL NEED INDEPENDENT BRACING VIA SPLAY WIRES (SEPARATE FROM ANY OTHER WIRES). PARTITIONS 6' OR LESS NO ATTACHMENT IS REQUIRED. 5) SPRINKLER HEAD PENETRATIONS MUST HAVE 2" OVERSIZED TRIM TO ALLOW 1" MOVEMENT IN ALL DIRECTIONS. 6) MANUFACTURER CERTIFICATION OF COMPONENT PERFORIANCE AND PERIODIC SPECIAL INSPECTION OF ANCHOR SYSTEM IS REQUIRED. 1) FOR CEILING AREAS EXCEEDING 2500 SF, A SEISMIC SEPERATION JOINT OR FULL HEIGHT WALL PARTITION NAT BREAKS THE CEILING SHALL BE PROVIDED. 8) ALL CROSS TEES SHALL BE CAPABLE OF CARRYING THE DESIGN LOAD WITHOUT EXCEEDING DEFLECTION EQUAL TO Y OF ITS SPAN. 9) ALL WIRE TIES ARE TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN 3 INCH. SECTION b08 5 0 ? Rb E C COD OMPLIANCE APPROVED DEC 11 2008 City Of Tukwila BumoN5 DIVISION WALL + 9' -6" AFF W/ INSULATION GYP BD CEILING W/ R -30 INSULATION EX. OFFICE RECEIV CITY OF TU LA DEC, 0: 3`2008 PERMIT CENTER N CD rn� COCO re) c0 N 0 0 N N LU z o Q a_ L_ 0 \ \WKST -4 \Documents \CAD \1987- 1989 \8734- 5\ANDREWS SPACE SUITE 123 \CD'S PHASE TWO \SD- 1,T- 1,T- 2.dwg, 12/1/2008 10:29 :04 AM, DesignJet 500 MAIN.pc3 �nr wsa »• NEW TENANT IMPROVEMENT AT GATEWAY NORTH