Loading...
HomeMy WebLinkAboutPermit D08-512 - MICROSOFT - DOORS, WALLS AND LIGHTINGMICROSOFT 3355 S 120 PL EXPIRED 08-10-09 D08 -512 Parcel No.: 1023049069 Address: 3355 S 120 PL TURIN Suite No: Tenant: Name: MICROSOFT Address: 3355 S 120 PL , TUKWILA WA Contractor: Name: DAVIS SCHUELLER INC. Address: 20700 44 AV W , LYNNWOOD WA 98036 Phone: 206 775 -9400 Contractor License No: DAVISSI105PN doc: IBC -10/06 City Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Contact Person: Name: JOAN HATCHEL Address: 10202 FIFTH AV NE, STE 102 , SEATTLE WA 98125 Phone: 206 547 -1940 DEVELOPMENT PERMIT Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA 98168 Phone: DESCRIPTION OF WORK: MODIFY DOORS, WALLS, AND LIGHTING IN PORTION OF EXISTING INTERIOR SPACE. Value of Construction: $57,000.00 Fees Collected: $1,473.00 Type of Fire Protection: SPRINKLERS AFA International Building Code Edition: 2006 Type of Construction: IA Occupancy per IBC: 0008 * *continued on next page ** Permit Number: D08 -512 Issue Date: 02/11/2009 Permit Expires On: 08/10/2009 Expiration Date: 07/01/2010 D08 -512 Printed: 02 -11 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: City (*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: • End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli The granting of this p -rmit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructi •. or the rformance of work. I a a thorized to sign and obtain this development permit. Signature: / __� Date: Z/ /e74: Print Name: doc:IBC - 10/06 N ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. W Permit Number: D08 -512 Issue Date: 02/11/2009 Permit Expires On: 08/10/2009 Date: 02- locl This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -512 Printed: 02 -11 -2009 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Tenant: MICROSOFT 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: D08 -512 Status: ISSUED Applied Date: 12/08/2008 Issue Date: 02/11/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) doc: Cond -10/06 D08 -512 Printed: 02 -11 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 22: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 23: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot -candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) The path of egress shall require emergency lighting until exit discharge is accomplished. 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) doc: Cond -10/06 D08 -512 Printed: 02 -11 -2009 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 28: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 29: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 31: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 32: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 33: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 34: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 35: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** D08 -512 Printed: 02 -11 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 D08 -512 • Date: Z /C7 9 ordinances governing or local laws regulating Printed: 02 -11 -2009 SITE LOCATION King Co Assessor's Tax No.: 1 623 04 O 49 Site Address: S S S S S. l a. -Tr 'P LAGS Suite Number: Tenant Name: MAC-00361 Property Owners Name: S A Be: -.1 LAC::•2Pb241rf t c� Mailing Address: CONTACT PERSON - who do we contact when your permit is ready to be issued Name: .\ (- — Ce--∎40- L- Mailing Address: I C. 2 OZ. - ci P A...!e r.-4. SJ,-r \c.Z S tr °L$ (2s City State Zip Fax Number: 2C)C. - S41 - ES 2.1 Z E -Mail Address: Mailing Address: k ca2c'Z. Contact Person: E -Mail Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwatukwila.wa.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** 22x1 tLa t(.- tt -I fvL'-JCC) ,�4 toc�'Z� SECT- State Zip CA% 1 (a Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) City Floor: 2. it New Tenant: ❑ Yes X..No Day Telephone: 2c>Co - tct a GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: T a . t Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: k t\ P, S Q:Wpplications\Ponns- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh L a our S, • s. g (.-1; City State Zip Day Telephone: - 2-e7 - S 41- l°t 4 Fax Number: 'Z0 Cp - S47 -%2 (2. ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: 1,-1 As Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 6 - BUILDING PERMIT INFOION — 206 - 431 -3670 • Valuation of Project (contractor's bid price): $ S7, 0 00 Existing Building Valuation: $ Scope of Work (please provide detailed information): MoPITY t)00 AS / WALLS / LIGN-77,4(7 1't� f 6!Z ?o N/ of EXI ST,..16 /II?"Egiog SrACE, Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) NA *For an Accessory dwelling, provide the following: Lot Area (sq ft): N Floor area of principal dwelling: /4/A Floor area of accessory dwelling: N �A *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Na GNAtJ6E. Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers g Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On line \3-2006 - Permit Application.doc Revised: 9 -2006 bit 1 . No If yes, a separate permit and plan submittal will be required. Compact: Di GAG t- Handicap: /JO G/IA4I' E. No If "yes ", explain: Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l Floor g g 2VL 2" Floor 1 S 3, z9 2- I o(o cAl 0 t -A e>, F - I 3 Floor I i3, 1.5 1, (006 15 Floors thru I ,! 0 9 c qf 95 1- A 5 PE+1T740v,SE Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck - BUILDING PERMIT INFOION — 206 - 431 -3670 • Valuation of Project (contractor's bid price): $ S7, 0 00 Existing Building Valuation: $ Scope of Work (please provide detailed information): MoPITY t)00 AS / WALLS / LIGN-77,4(7 1't� f 6!Z ?o N/ of EXI ST,..16 /II?"Egiog SrACE, Will there be new rack storage? ❑ Yes Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) NA *For an Accessory dwelling, provide the following: Lot Area (sq ft): N Floor area of principal dwelling: /4/A Floor area of accessory dwelling: N �A *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Na GNAtJ6E. Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers g Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\Applications\Forms- Applications On line \3-2006 - Permit Application.doc Revised: 9 -2006 bit 1 . No If yes, a separate permit and plan submittal will be required. Compact: Di GAG t- Handicap: /JO G/IA4I' E. No If "yes ", explain: Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR a;_.. ORIZED AGEN Date: i 0.-/S/2-0 Day Telephone: ZO(o. 547. /7 40 Mailing Address: IOZoZ 5 71.4 Ave- me_, SUITE 10.2- SC 4t ( L E 9 -5 Print Name: MI C7LSG Date Application Expires: _r _ n f 0 ,„ Date Application Accepted: 1210.1 Lot Q:\Applications\Forms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh City State Staff Initials: Zip Page 6 of 6 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: MICROSOFT Receipt No.: R09 - 00230 Initials: JEM User ID: 1165 Payee: KDW ARCHTECTURE ENGINEERING TRANSACTION LIST: Type Method Descriptio Amount Payment Check 36242 894.50 ACCOUNT ITEM LIST: Description doe: Receiot -06 BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/322.100 890.00 640.237.114 4.50 Total: $894.50 S Permit Number: D08 -512 Status: APPROVED Applied Date: 12/08/2008 Issue Date: Payment Amount: $894.50 Payment Date: 02/11/2009 11:32 AM Balance: $0.00 PAYMENT RECEIVED Printed: 02 -11 -2009 Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: MICROSOFT Receipt No.: R08 -03891 Initials: JEM User ID: 1165 Payee: KDW, PS • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 35920 578.50 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIPT Account Code Current Pmts 000/345.830 578.50 Total: $578.50 Permit Number: D08 -512 Status: PENDING Applied Date: 12/08/2008 Issue Date: Payment Amount: $578.50 Payment Date: 12/08/2008 10:39 AM Balance: $894.50 0289 12/08 9707 TOTAL 578.50 doc: Receiot -06 Printed: 12 -08 -2008 Project Info Project Address 3355 S 120th Place Date 12/8/2008 Tukwila, WA 98168 For Building Department Use Fr" �� v L -an; �n9 O y 3 / A Applicant Name: PP Joan Hatchel Applicant Address: 10202 5th Avenue NE, Suite 102, Seattle, WA 98125 Applicant Phone: 206 -547 -1940 Project Description 891.0 ❑ New Building ❑ Addition -' Alteration ✓ Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting . Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Location (floor /room no.) Occupancy Description Allowed Watts per ft Area in ft Allowed x Area 3 / 308 22 Conference Room 1.12 891.0 999.7 3 / 309B 280.0 Conference Room 1.12 93.0 104.3 3 / 309C 2' Linear Fluorescent, 1 T -5 lamp, elect. dimming ball. Conference Room 1.12 93.0 104.3 4' Fluorescent sconce, 2 T -8 lamps, elect. dimming bal htlif 64.0 64.0 3 / 309C 4' Fluorescent sconce, 2 T -8 lamps, elect. dimming ba r4 Yr LOD vitip , - 64.0 a rr . 64.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1208.4 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 3 / 308 4' Linear Fluorescent, 1 T -5 lamp, elect. dimming ball. 22 28.0 616.0 3 / 308 4' Linear Fluorescent, 1 T -5 lamp, elect. dimming ball- 10 28.0 280.0 3 / 308 2' Linear Fluorescent, 1 T -5 lamp, elect. dimming ball- 4 13.0 52.0 3 / 308 2' Linear Fluorescent, 1 T -5 lamp, elect. dimming ball. 2 13.0 26.0 3 / 3098 4' Fluorescent sconce, 2 T -8 lamps, elect. dimming bal htlif 64.0 64.0 3 / 309C 4' Fluorescent sconce, 2 T -8 lamps, elect. dimming ba r4 Yr LOD vitip , - 64.0 a rr . 64.0 OM Paiit; pr cce:1 DEC 1 e 200 Total Proposed Watts may not exceed Total Allowed Watts or Inte s.. -- o¢ Tu o . ' � • •_ed alts o 1102.0 Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Maximum Allowed Lighting Wattage Proposed Lighting Wattage 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), numb'er`df- _�, u lah,• ur , and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, an: • . 41 ormation. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. CITY 0��ELA 0 8 20U8 PER M CENTE Notes: 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Use' LPA (W /sf) Use' LPA (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) " 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars 1.3 Post office 1.1 Dormitory 1.0 Retail retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries 1.3 Plans Submitted for Common Areas Only Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers *Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw - in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -1 Unit Li htin Power Allowance (LPA Footnotes for Table 15 -1 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. Project Info Prof Addres' 3355 S 120th Place Date 12/8/2008 Tukwila, WA 98168 For Building Department Use Name: Joan Hatchel Appl. Name 10202 5th Avenue NE, Suite 102, Seattle, WA 98125 Appl. Phone 206 -547 -1940 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Non - Tradable Locations Description Allowed Watts per ft or per If Area (ft perimeter (If) or # of items Allowed Watts x ft (or x If) Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Tradable Maximum Allowed Lighting Wattage Tradable Proposed Lighting Wattage Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Non - Tradable Proposed Lighting Wattage Proposed Watts may not exceed Allowed Watts for Category O C44 A t4 U- S o f k J 4— Total Allowed Watts Revised July 2007 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Total Proposed Watts Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft Stairways 1.0 W /ft Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/ft Street frontage for vehicle sales lots in addition to "open area" allowance 20 W /linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W /ft for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft Drive -up windows at fast food restaurants 400W per drive - through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG-EXT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 Location (floor /room no.) Occupancy Description Allowed Watts per ft Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft 3 / 308 Conference Room 1.10 10.0 feet 9 feet 1.12 3 / 309B Conference Room 1.10 10.0 feet 9 feet 1.12 3 / 309C Conference Room 1.10 10.0 feet 9 feet 1.12 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA Project Address 1 3355 S 120th Place Date 12/8/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft Carry the Adjusted LPA to the corresponding "Allowed Watts per ft location on LTG -SUM. Adjusted Lighting Power Allowances (Interior ** From Table 15 -1 based on exceptions listed in footnotes Revised July 2007 Lighting, Motor, 2006 Washington State Nonresidential and Transformer Energy Code Compliance Forms Permit Plans Checklist LTG -CHK Revised July 2007 Project Address 3355 S 120th Place 'Date 12/8/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations A - G - 02 n.a. 1513.2 Area controls Maximum limit per switch n. a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations A - G - 02 n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning A -G -02 EXIT SIGNS (Section 1514) yes I 1514 IMax. watts 'Indicate watts for each exit sign IA -G -02 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture A -G -02 n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers (Indicate size and efficiency I I • 2006 Washington State Nonresidential Energy Code Compliance Form If "no" is circled for any question, provide explanation: EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or 2006 Washin ton State Nonresidential Ener• Code Corn • fiance Form • Lighting, Motor, and Transformer 2006 Washington State Nonresidential Energy Code Compliance Forms Permit 1Plans Checklist LTG -CHK Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft or 5% of the building footprint for footprints over 100,000 ft whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). JOAN HATCHEL 10202 FIFTH AV NE, STE 102 SEATTLE WA 98125 RE: Permit No. D08 - 512 3355 S 120 PL TUKW Dear Permit Holder: -or- Sincerely, c Bill Rambo Permit Technician File: Permit File No. D08 -512 City of Tukwila Department of Community Development Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/10/2009. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period. 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 08/10/2009, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Jim Haggerton, Mayor 6.3nn .cn„thrpntpr Rnulevard. Suite #100 o Tukwila. Washington 98188 o Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 ACTIVITY NUMBER: D08 -512 DATE: 12 -08 -08 PROJECT NAME: MICROSOFT SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT: filA Building Division Public Woks 4- lq- i E ERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete E Comments: � PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP Fire 611 Prevention APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Structural Incomplete ❑ DATE: DATE: Planning Division Permit Coordinator Not Applicable TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DUE DATE: 01-06 -09 Not Approved (attach comments) ❑ DUE DATE: 12-09-08 El Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Permit Center Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ' ill111IIIUi 1111 II' Iuu1 i La- [ cri [ J T Lj ELLIOTT BAY PROJECT SITE M.S. Project No. P. 1 1540 0 11 CODES FOR EXIST. BLDG.: CODES FOR THIS PROJECT: ZONING: SEISMIC ZONE: 3 CEO CODE INFORMATION PARCEL NO.: 1023049069 CONSTR. TYPE: TYPE 1 -A 1997 UBC 1997 UFC 1997 UMC 1994 WA. STATE ENERGY CODE 1994 WA. STATE BARRIER FREE CODE 2006 INTERNATIONAL BUILDING CODE 2006 INTERNATIONAL FIRE CODE 2006 INTERNATIONAL MECHANICAL CODE 2006 UNIFORM PLUMBING CODE 2005 NATIONAL ELECTRIC CODE 2006 WA. STATE ENERGY CODE 2006 WA. STATE INDOOR AIR QUALITY CODE MIC /H (MANUFACTURING INDUSTRIAL CENTER /HEAVY) GENERAL NOTES E 4. WORKING HOURS ARE TO BE COORDINATED WITH CLIENT. BUILDING AREA: OCCUPANT LOAD: PARKING: SCOPE OF WORK: 1. VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING WORK. INFORMATION FOUND IN THESE DOCUMENTS DO NOT NECESSARILY REFLECT EXISTING CONDITIONS, AND SHOULD NOT BE HELD ACCOUNTABLE FOR THEIR CONTENT OR ANY IMPACT ON PROJECT MISCOORDINATION. FOR AREAS OF CONCERN FIELD VERIFICATION IS NECESSARY. 5. THE INTENT OF THE DRAWINGS IS TO SHOW GENERAL SCOPE AND INTENT OF THE WORK. METHODS AND MATERIALS NOT EXPLICITLY IMPLIED ARE INTENDED TO BE BUILDER DESIGNED. 9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY PRECAUTIONS TO PROTECT OWNERS FACILITIES FROM DUST, DEBRIS AND WATER DAMAGE DUE TO WORK DONE IN THIS CONTRACT. PROVIDE TEMPORARY DUST AND MOISTURE PROTECTION WHETHER OR NOT INDICATED ON PLAN. 10. PROVIDE FIRE CAULK AND DAMPERS TO MAINTAIN RATED SYSTEMS AT ALL PENETRATIONS. O FIRST FLOOR: 188,222 SQ.FT. SECOND FLOOR: 183,292 SQ.FT. SECOND FLOOR: 183,292 SQ.FT. PENTHOUSE: 1,109 SQ.FT. TOTAL: 555,915 SQ.FT. 11. MICROSOFT CORPORATION HAS FIRST SALVAGE RIGHTS TO ALL STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL AND LANDSCAPE ITEMS NOT BEING UTILIZED IN THIS SCOPE OF WORK. VERIFY SALVAGE DESIRES PRIOR TO DISPOSAL. NO CHANGE TO EXISTING OCCUPANT LOADS. REFERENCE COORDINATION SHEETS. NO CHANGE TO EXISTING PARKING. TENANT IMPROVEMENTS IN BUILDING #5 TO AREA "A" OF EXISTING DATA CENTER. WORK INCLUDES MINOR MODIFICATIONS TO DOORS AND WALLS. OCCUPANCY: B (OFFICE) B (UPS ROOM QUALIFYING UNDER IFC 608) F -1 (DATA ROOMS - RAISED FLOOR AREA) H -3 (GENERATOR ROOM) 2. ALL EXISTING WORK DAMAGED BY WORK IN THIS CONTRACT AND SCHEDULED TO REMAIN SHALL BE REPAIRED TO MATCH ADJACENT FINISHES AND IS SUBJECT TO REVIEW AND APPROVAL BY ARCHITECT AND OWNER 3. COORDINATE ALL WORK WITH OTHER TRADES. PROVIDE FOR NECESSARY NEW OPENINGS FOR WORK ITEMS PASSING THROUGH WALLS, FLOORS AND CEILINGS AS REQUIRED. PATCH AND REPAIR AS REQUIRED. MAINTAIN ALL RATED SYSTEMS. 6. QUALITY OF MATERIALS AS SPECIFIED SHALL 'BE CONSIDERED MINIMUM AND ANY CHANGE SHALL BE OF DEMONSTRATED EQUAL OR BETTER QUALITY UNLESS SPECIFICALLY RELEASED BY OWNER AND APPROVED BY THE BUILDING DEPARTMENT. MATERIALS NOT SPECIFIED SHALL BE OF A HIGH QUALITY INTENDED FOR COMMERCIAL USE.. MATERIALS ARE TO BE INSTALLED IN A PROFESSIONAL MANNER TO THE HIGHEST INDUSTRY STANDARDS, ALL PARTS TO BE COMPLETE AND OPERATIONAL. 7. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO AVOID INTERFERENCE BETWEEN DIVISIONS OF THE WORK. WHERE INSTALLATION AND /OR CONNECTION OF EQUIPMENT IS NOT SPECIFIED AND WHERE SUCH CONNECTION AND /OR INSTALLATION IS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR SUCH CONNECTION AND /OR INSTALLATION. 8. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWING AND ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE FOUND. n SECOND FLOOR SCALE: 1/32" = 1' -0" QO O 0 LEGAL DESCRIPTION LOT 5: THAT PORTION OF GOVERNEMTN LOT 15 AND THE SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER, SECTION 10 AND THE SOUTHEAST QUARTER, SECTION 9, ALL IN TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: COMMENCING AT THE WEST ONE- QUARTER CORNER OF SAID SECTION 10; THENCE SOUTH 01 °46'02" WEST ALONG THE WEST LINE THEREOF A DISTANCE OF 107.22 FEET TO A POINT ON SAID LINE; THENCE LEAVING SAID LINE SOUTH 87 °33'12" EAST A DISTANCE OF 512.24 FEET; THENCE SOUTH 01 °46'02" WEST A DISTANCE OF 402.93 FEET; THENCE NORTH 88 °13'58" WEST A DISTANCE OF 402.96 FEET; THENCE SOUTH 3Z09'15" EAST A DISTANCE OF 26.64 FEET; THENCE SOUTH 2Z04'16" EAST A DISTANCE OF 220.58 FEET TO A POINT ON THE WEST LINE OF SAID GOVERNEMNT LOT 15; THENCE LEAVING SAID WEST LINE SOUTH 20 °30'45" EAST A DISTANCE OF 471.28 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 88°14'26" EAST A DISTANCE OF 363.52 FEET; THENCE SOUTH 01 °46'06" WEST A DISTANCE OF 80.08 FEET; THENCE SOUTH 88 °13'58" EAST A DISTANCE OF 227.95 FEET; THENCE SOUTH 01 °46'02" WEST A DISTANCE OF 38.13 FEET; THENCE SOUTH 89 °18'50" EAST A DISTANCE OF 50.01 FEET TO THE EASTERLY MARGIN OF THE VACATED 35TH AVENUE SOUTH AS VACATED BY CITY OF TUKWILA ORDINANCE NO. 1978; THENCE SOUTH 01 °46'02" WEST ALONG SAID MARGIN A DISTANCE OF 613.65 FEET TO THE SOUTHEASTERLY CORNER OF SAID ROAD VACATION; THENCE NORTH 89°18'50" WEST A DISTANCE OF 270.10 FEET; THENCE SOUTH 01°46'02" WEST A DISTANCE OF 73.78 FEET; THENCE NORTH 89 °18'50" WEST A DISTANCE OF 50.02 FEET TO THE NORTHEAST CORNER OF LOT 10, DONALDSON ADDITION, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 20 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, WASHINGTON; THENCE NORTH 01 °46'02" EAST A DISTANCE OF 247.71 FEET; THENCE NORTH 88'13'58" WEST A DISTANCE OF 321.41 FEET; THENCE NORTH 01 °46'02" EAST A DISTANCE OF 562.98 FEET TO THE TRUE POINT OF BEGINNING. SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING, STATE OF WASHINGTON ABBREVIATIONS © AT CENTERLINE # NUMBER SQUARE FEET X° DEGREE(S) ACOUS. ACOUSTICAL AC.T. ACOUSTICAL TILE ADJ. ADJACENT ADJUS. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR ALT. ALTERNATE APPROX APPROXIMATE ARCH. ARCHITECT BD. BOARD BET. BETWEEN BLDG. BUILDING BLK. BLOCK BLKG, BLOCKING BOT. BOTTOM CAB. CABINLI CER. CERAMIC CIRC. CIRCLE CLG. CEILING CLR. CLEARANCE) COL. COLUMN CONST. CONSTRUCTION CONT. CONTINUOUS CONTR. CONTRACTOR CORR. CORRIDOR CPT. CARPET CTR. CENTER DEMO. DET. DIAM. DIM. DEMOLITION DETAIL DIAMETER DIMENSION DN. DR. DWG. EA. EL. ELEV. EQ. EQUIP. EXH. EXIST. EXT. F. E. F.E.C. FIN. FT. G.B. GEN. GL. G.W. B. GYP. H.C. HD. HDR. HDWR. H.M. HORIZ. HR. HT. H.V.A.C. INSUL. I NT. JAN. JT. NORTH 3 14 DOWN DOOR DRAWING EAC H ELEVATION ELEVATOR EQUAL EQUIPMENT EXHAUST EXISTING EXTERIOR FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH(ED) FLR. FLOOR FOOT/FEE! GAGE GRAB BAR GENERAL GLASS/GLAZING GYPSUM WALL BOARD GYPSUM HOLLOW CORE HEAD HEADER HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATING & AIR CONDITIONING INSULATION INTERIOR JANITOR JOINT LAV. LAVATORY L.H. LEFT HAND LIN. LINOLEUM MAX. MAXIMUM MECH. MECHANICAL MTL. METAL MEZZ. MEZZANINE MFR. MANUFACTURE(R) MIN. MINIMUM MISC. MISCELLANEOUS MTD. MOUNTED OH. OPNG. OPP. P. BD. PLAM PLWD. PNL. PR. PTN. RAD. REF. REFL. REQ. N. NORTH N.I.C. NOT IN CONTRACT NO. NUMBER NOM. NOMINAL N.T.S. NOT TO SCALE O.A. OVERALL O.C. ON CENTER O.D. OUTSIDE DIAMETER O.F.O.I. OWNER FURNISHED/ OWNER INSTALLED OVERHEAD OPENING OPPOSITE PARTICLE BOARD PLASTIC LAMINATE PLYWOOD PANEL PAIR PARTITION RADIUS REFERENCE REFLECTED REQUIRED www11821 � i, 1: wu sr- 111111111N110111111 ,. ���''' 1111111111 uoiu" 1111 i A REA QF W ORK _. !uuuuoum u I (12 c-AJ6 R.H. RIGHT HAND R.O. ROUGH OPENING S. SOUTH S.C. SOLID CORE SCH. SCHEDULE SECT. SECTION SIM. SIMILAR SPEC. SPECIFICATION SQ. SQUARE S.STL. STAINLESS STEEL STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURE SUSP. SUSPENDED TEL TELEPHONE TEMP. TEMPERED THK. THICKNESS T.V. TELEVISION TYP. TYPICAL UNFIN. UNFINISHED U.N.U. UNLESS NOTED OTHERWISE VCT VEN. VERT. VEST. VFY. V.W.C. W. W/ WD. W/0 WSCT. WT. VINYL COMPOSITE TILE VENEER VERTICAL VESTIBULE VERIFY VINYL WALL COVERING WEST / WIDE WITH WOOD WITHOUT WAINSCOT WEIGHT VICINITY MAP SYMBOLS -M - DETAIL / PLAN REFERENCE F2 (24) A SECTION REFERENCE ELEVATION REFERENCE NORTH REFERENCE ROOM NUMBER SEA -TAC INT'L AIRPORT DOOR NUMBER SECURITY CARD READER WALL TYPE CONSTRUCTION KEY NOTE REFERENCE DATUM POINT BREAKLINE SYMBOL REVISION REFERENCE 0 SPRINKLER HEAD 0 S.P. C, (D) (E) (N) NEW (R) RELOCATED STAND PIPE EXIT LIGHT DEMOLISH EXISTING 'MO Q 9 BA 0 F.E.C. FIRE EXTINGUISHER CABINET THIRD FLOOR SCALE: 1 /32" = V-0" O O ® 00 PROJECT TEAM PROJECT MANAGER JAMIE VANEK GRUBB & ELLIS MANAGEMENT SERVICES, INC. MICROSOFT CORPORATION 425 - 882 -8080 ARCHITECT DOUGLAS A. DIEL KDW, PS ARCHITECTURE /ENGINEERING 10202 5TH AVE NE SEATTLE, WA 98125 206 - 547 -1940 CONTRACTOR T.B.D. SHEET INDEX SEPARATE PERMIT REQUIRED FOR: i electrical Plumbin 4rJ Gas Piping City of Tukwila BUILDING DIVISIO 00 NORTH 0 `9 12 13 14 F Permit Flo. Pia review approval is subject to errors and on i . si f pprO.!a of construction docurnent3 doe3 not auh thr \!iolatiOf1 of any adopted code or ordinaWWO. Re . o{ Epprov€;d Field 'py and conditions is aefznc otP:;f By /�_ Date: Z City of TuIvarila BU LDiN1 D1VPI A -A -01 - COVER SHEET AND FLOOR PLANS A -B -01 - SITE PLAN A -F -01 - FURNITURE PLANS A -G -01 - SECOND FLOOR ENLARGED PLANS A -G -02 - THIRD FLOOR ENLARGED PLANS A -G -03 - FINISH PLANS A -M -01 - DETAILS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j RECEIVE CITY OF T / 1%A DEC 0 8 2008 PERMIT CENTER 0 ci? (2_ Drawn TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 Revisions No. Dote Description 12 -1 -08 CONSTRUCTION DRAWINGS 12 -8 -08 BUILDING PERMIT ARCHITECTURE ENGINEERING IIMEMEMISIMINEMESErl Design Team Design JOAN HATCH EL AB Checked DOUGLAS A. DIEL Date 12 -08 -08 Internal Project No. K -08 -00445 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Registration 3912 REGISTERED ARCHITECT G(AS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title apte COVER SHEET AND FLOC , LANs PERMIT DRAWINGS 12 -08 -08 Sheet Title A -A -01 u) U) H. IMES PP CD L. J 0, 1 .7.) or; - if; j 0 cs 1 =05 R=1265.90' [=126.32' Cr 0 589'16'42"E OCCUPANCY F v I—FR SPRINKLERED PARKING 1/1000=188 156.0' .C RY ,.Agell,,.4,,,7777*::77.7-7p740.:';d!! V wh'..x 4 .,:e%% // ROCKERY NO) CF::q r 7/ Iftr—CTILC)1- Pr 224.42' _ ■ A41 FH 3311 S. 120TH PL. - EXIST:NC PASK PH 1 /1 -- 1 3333 S. 120TH PL. T7111 1 1 BUILDING 2 107,489 S.F. OCCUPANCY S PARKING 1/1000=108 V-N SPRINKLERED BUILDING 3 161,445 S.F. OCCUPANCY F PARKING 1/1000=161 V-N SPRINKLERED CHAIN MU( FENCE N89' ia'sol'w 300.00' (.SITE PLAN SCALE: 1" . 100 I -"A te„-- IIIII III!II II ii 11/ 1 4_ H t 11 LL 1-i-U— BLDG. #5 SWITCH GEAR az — , -- :L... _ _r---- , ----_-:_-__ _. ---- — r- _ . ---.--- --- - -------- . -____„.------.- ____________ _ _ • -- _____ ----------. 1 1 1 1 1 1 1 1 WML PUMP STATION SWITCH & ALARM NORTH METRO TRANSIT BASE CA1ED Eolg2,1zU H.1.AF 12S ' r7A LOADIR RAMP EX BLDG rn SALMON EGG \ BARREL '0 SIR AM 55CAL. 3411 S. 120TH PL. N89'18'15"W I - ( -- • - kfT(7.1 CPD 3433 S. 120TH PL. BUILDING 4 115,895 S.F. OCCUPANCY F PARKING 1/10 0 0=116 V-1 HR SPRINKLERED 2 — S - T — R — E — E — T — Al 1 219.99' rIT1 CO PP BUILDING 1 98,564 S.F. OCCUPANCY F PARKING 1/1000=99 V-N SPRINKLERED FIVER POLE 4 L00 2 H EXISTING BUILDING - P C E 1 3 2 511 67 H PL. - BLDG. 6 r EXISTING BUILDING J FH WETLA D METRO TRANSIT BASE I I EX ISLUG ■ ADO 0 9 2009 DOB 512 RECEIVED CITY OF TUKWILA DEC 0.8 2008 PERMIT CENTER "': ' S'ex •F . n i ;• `'S. , :% • •■4Mem TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 No. Date Description 12-1-08 CONSTRUCTION DRAWINGS 12-8-08 BUILDING PERMIT ARCHITECTURE ENGINEERING Design Team Design JOAN HATCH EL Drawn AB Checked DOUGLAS A. DI EL Date 12-08-08 Internal Project No. K-08-00445 M.S. Project No. P. 11540 MMEIMINEMEIMMINEEDEr Revisions KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Registration 3912 REGISTERED ARCNI TEC GLAS A. Of EL STATE OF WASHINGTON )C-t .. \ti 4%4(7,00' ... , Irlmill1 717 1m ,. 111--- Key Plan Sheet Title SITE PLAN PERMIT DRAWINGS 12-08-08 Sheet Title A-B-01 a z ,-a• < 2uJ !A Z w 0 ) 0 [1: J 1. a. JAN 0 r BULLETIN BD, FIRST AID Q' 0 1' 2' 4 PARTIAL SECOND FLOOR FURNITURE PLAN SCALE: 1/2" = 1' — SF:24 309D 309B SCALE: 1/4" = 1' — SF:48 0 1 2 4 8 VE\ DING R P' PARTIAL THIRD FLOOR FURNITURE PLAN OFFICE L306j WC VACH IN ES /N POP POPCORN MACHINE 9TYP. OPEN OFFICE 309 4' OFFICE 305 5 0 MA NFERENCE 309A I II M TYP. N/\/\/\/\/\/\/\/\/\/\ 00 3'-6" rt OFFICE [30J 1 V BD CONFERENCE ROOM 308 20'-0" — 1 j L H / / N N N 33c TYP. ELEV. EQPM. ACCESS 304 UP 7/ 315 314 COPIER HP 8100 ELEV. #1 —I a L S U U ' 1 R \ 15 16 ()KEY NOTES: 2. MS STANDARD TRASH LINERS. PROVIDE (3) LINERS PER RECYCLE CABINET. OKEY NOTES: 7. (6) MS STANDARD CONFERENCE ROOM CHAIRS. 8. 42" DIAMETER TABLE. 9. (3) KEILHAUER 'CELIA' CHAIRS 10. (3) SIDE TABLES, KEILHAUER 'CAL' 11. (3) STEELCASE 'MOVE' SIDE CHAIR 12. 36" x 72" KI PORTICO TABLES 13. (8) MICROSOFT STANDARD TASK CHAIRS. SCOPE OF WORK BY WORKPLACE DEVELOPMENT. G.C. TOO COORDINATE. 1. KI (3) SECTION MS STANDARD 24" DEEP RECYCLE CABINET WITH MAPLE TOP Sc (2) BACK FILLER PANELS. PROVIDE AND INSTALL MICROSOFT STANDARD RECYCLE STICKERS. SCOPE OF WORK BY WORKPLACE DEVELOPMENT. G.C. TOO COORDINATE. 1. 20' MS WEDGE CONFERENCE TABLE. TABLE TO COME FROM EXISTING MS WAREHOUSE STOCK, COORDINATE WITH G.C. DELIVERY OF TABLE TO SITE FOR ELECTRICAL AND A/V WORK. 2. KI (3) SECTION MS STANDARD 24" DEEP RECYCLE CABINET WITH MAPLE TOP & (2) FILLER PANELS. PROVIDE AND INSTALL MICROSOFT STANDARD RECYCLE STICKERS. 3, MS STANDARD TRASH LINERS. PROVIDE (6) LINERS FOR RECYCLE CABINET. 4. (13) EXISTING CONFERENCE ROOM CHAIRS IN ROOM 308 TO REMAIN. PROVIDE (7) NEW CONFERENCE ROOM CHAIRS TO MATCH EXISTING. 5. (8) EXISTING SIDE CHAIRS TO REMAIN IN CONFERENCE ROOM 308. 6. 60" DIAMETER TABLE, KI DATA LINK WITH POWER MODULE FOR DATA & A/V IN TABLE TOP. 14. PROVIDE AND INSTALL MS STANDARD SIGNAGE FOR ROOMS 309 A—D; A1.1 NAMEPLATE 51/2" WIDE. PROVIDE INSERT WITH ROOM NAMES AS NOTED ON PLANS. AUG 0 9 moo too8c* RECEIVED CITY OF TUKWILA Ike 0 81O05 PERMIT CENTER ---- 1111111111=2119111MMENINSERF -- TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 Revisions No Dote Description 12-1-08 CONSTRUCTION DRAWINGS 12-8-08 BUILDING PERMIT ARCHITECTURE ENGINEERING Design Team Design JOAN HATCHEL Drawn AB Checked DOUGLAS A. DIEL Date 12-08-08 Internal Project No. K-08-00445 M.S. Project No. P. 11540 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f vvww.kdw.net 3912 Registration REGISTERED OOtI GI.AS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title FURNITURE PLANS PERMIT DRAWINGS 12-08-08 Sheet Title A-F-01 on C) BULLET' \ BD. FIRST AID P' VENDI\G MACHI PARTIAL SECOND FLOOR ENLARGED PLAN SCALE:1/2" = 1' - SF:24 0 1' 2 4' 0 1' 2 4' P' r C iS POP POPCORN MACHINE PARTIAL SECOND FLOOR ENLARGED REFLECTED CEILING PLAN SCALE:1/2" = 1' - SF:24 RECYCLE L _L 0 L I Q WOMEN 212 0 0 r - 209B N N / 7' -1" 7 / / / / / OFFIC 207A SF: 98 OLF: 100 OL: 1 0 Q' Q' 8 HP 8100 N N R R HALLWAY L2_ 13 206 161 ®KEY NOTES: 0-, ARCHITECTURAL 1. DEMO EXISTING COUNTER, CABINET BASE AND UPPER CABINETS. ADD FINISHED END AT UPPER CABINET, PL-3/A-M-01. 2. NEW WALL FROM FLOOR TO SUSPENDED CEILING. 3. PROVIDE NEW CABINET AND COUNTER - SEE ELEVATION 4. EXISTING COPIER AND PRINTER TO REMAIN 5. PROVIDE CORNER GUARDS AT ENTRANCE TO ROOM, 1" SATIN STAINLESS, 48" HIGH 6. PROVIDE NEW CABINET FOR POPCORN MACHINE 7. EXISTING HR BOARD TO REMAIN. 8. EXISTING VCT FLOOR TO REMAIN. PROVIDE NEW WALL BASE. MATCH EXISTING IN ROOM. PAINT ALL WALLS. SEE FINISH SCHEDULE A-M-01 AND A-C -03 FOR EXTENT OF WORK. 9. EXISTING JOB RACK AND SHRED CABINETS RELOCATED ELEC. 8c COMM. 10. EXISTING POWER AND DATA PACK TO REMAIN FOR COPIER AND PRINTER 11. PROVIDE DUPLEX AT 42"AFF ABOVE COUNTER FURNITURE & SIGNAGE (COORDINATE WITH WORKSPACE DEVELOPMENT) SEE A-F-01 12. REMOVE EXISTING FURNITURE (2) BOOKCASES, (1) MAIL CABINET (3) FREESTANDING TRASH CONTAINERS WALL TYPE LEGEND: \/\/\./ /\/\/\/\/\/\/ OKEY NOTES: 1. RELOCATE (1) LIGHT FIXTURE AS SHOWN. SWITCH WITH BREAKROOM LIGHTS. 2. RELOCATE HVAC AS REQUIRED BY CODE AND MS STANDARDS. 3. RELOCATE SPRINKLERS AS REQUIRED BY CODE. SYMBOLS LEGEND: lIJJp c=b DEMOLISHED WALLS NEW PARTIAL HEIGHT WALL TO SUSPENDED CEILING EXISTING WALL TO REMAIN FOCAL POINT AVENUE A FAVA-NS-1T5-1C-120-D-G1-WH-2' FOCAL POINT AVENUE A FAVA- NS- 1 T5- 1 0-1 20--D-G1 -WH -4' FOCAL POINT AVENUE B LINEAR FLUORESCENT FAVB-PL- 1 T5- 1 C-1 20- D(ECO- 1 0)--T1T-L835-WE FOCAL POINT AVENUE B LINEAR FLUOESCENT FAVB- PL-- 1 T5- 1 C-1 20-D(ECO- 1 (3)--ri T-L835-WH---zr FOCAL POINT FS6 WALL SCONCE FS6-1'-1BS18-1C-120-E-WM-L835-WH 2X4 RECESSED FLUORESCENT LIGHT FIXTURE EMERGENGY LIGHT FIXTURE EMERGENGY EXIT LIGHT FIXTURE LCSO LIGHTING CONTROL STATION AUO 0 9 ZUU4 O8 5/2 0 8 n< HVAC DIFFUSERS HVAC AIR RETURN HVAC AIR RETURN CEILING MTD PROJECTOR CEILING MTD PA SPEAKER CEILING MTD CONF. RM SPEAKERS MOTION DETECTOR SPRINKLER HEAD SMOKE DETECTOR LIGHT SWITCH RECEIVED CITY OF TUKWILA UEC 0 8 2008 PERMIT CENTER --- MESEffnnnninagtigtNnnl Revisions No. ARCHITECTURE ENGINEERING Design Drawn Checked AB Date 12-08-08 Internal Project No. M.S. Project No. P. 11540 3912 Design Team JOAN HATCH EL DOUGLAS A. DIEL K-08-00445 Registration REGISTERED ARCHITECT DO UGLAS A. DIEL STATE OF WASHINGTON Key Plan Bar Code Sheet Title PERMIT DRAWINGS 12-08-08 Sheet Title TUKWILA 5 3355 S. 120th PLACE TUKWILk WA 98168 Dote Description 12 CONSTRUCTION DRAWINGS 12-8-08 BUILDING PERMIT C. KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net SECOND FLOOR ENLARGED PLANS A-G-01 JAN FOCUS 309C SF: 93 OLF: 100 OL: 1 O �� OFFICE 309B SF: 93 OLF: 100 OL: 1 OPEN CE =MBE / �N�U / EllaillE11111 / ER //// II la I m° 1111 II 11111.111111M11 111111111111111111111M11111111111111 3|M. OFFICE 309A SF: 138 OLE: 100 OL: 2 OFFICE EQUAL ELEV. EQPM. ACCESS VESTIBULE 301 TUKWILA 5 3355 S. 120th PLACE �������� ��" U�����UU TUKWILA, A W A 98168 OntigNEMBEEZZEMEM Revisions No . Dote Description 12-1-08 CONSTRUCTION DRAWINGS 12-8-08 BUILDING PERMIT _ � h CL O 1 ' 2' 4' 8. PARTIAL THIRD FLOOR ENLARGED PLAN SCALE: ' ----. ' 8 . PARTIAL THIRD FLOOR ENLARGED REFLECTED CEILING PLAN / / / / / L S kACE_ PROJECT D O -�8 7- U�U.L . -_ [-- 3 ' T 304\ , / 315 314 ` U 15 16 15 16 MICROSOFT . REFERENCE DOCUMENTATION FOR THIS PROJECT: MEDIUM http://psdg.refdg.com/ version: Sept/Oct. 2008 (MSAV Conference Room Guidelines 10.0\ OKEY NOTES: a. NEW 3'-0" X 8'-O" MAPLE WOOD DOOR AND H.M. FRAME, DOORS CLEAR FINISH, WITH FULL GLASS PANEL PANEL. FRAMES - PAINT TO MATCH EXISTING ON FLOOR. b. PROVIDE AND INSTALL NEW LOCKS (4 (2) EXISTING DOORS. ARCHITECTURAL 3. EXISTING FLOOR-TO-CEILING VINYL 'WALLTALKERS' WALL COVERING TO REMAIN. DEMO ALL WIREMOLD AT NORTH WALL • NEW GWB WALLS FROM FLOOR TO SUSPENDED CEILING. ROOM 309. PROVIDE AND INSTALL Y.4 GWB AT NORTH WALL OF ROOMS 309A, B & C FROM FLOOR TO 2-9) AFF. INSTALL ON TOP OF EXISTING VINYL 'WALL TALKERS' WALL COVERING. TOP WITH TRAY RAIL. CLEAN EXPOSED 'WALLTALKERS' WALL COVERING. ADD NEW FROM WALL TALKERS FROM SURPLUS IN ROOM 308. VERIFY EXTENT OF SCOPE WITH ARCHITECT. . PROVIDE AND INSTALL . 2-9Y4." AFF. INSTALL ON TOP OF -_-' FROM _-- EXISTING VINYL 'WALL TALKERS' WALL COVERING. PROVIDE AND INSTALL NEW 'WALLJALKER' . WALL CUVLH|N � ��U�8 |U� OF TRAY RAIL TO SUSPENDED CEILING. RUN HORIZONTALLY. 5. PROVIDE AND INSTALL NEW CUSTOM CASEWORK WITH P-LAM COUNTER AND BACKSPLASH, SEE ELEVATION A-W-01 6. EXISTING CARPET TO REMAIN, PROVIDE AND INSTALL NEW WALL BASE AT NEW WALLS. MATCH EXISTING. 7. RELOCATE FLAT PANEL DISPLAY FROM CONFERENCE ROOM 508 TO ROOM 309A. PROVIDE AND INSTALL CHIEF MANUFACTURING FLAT PANEL WALL MOUNT, COORDINATE WITH MS AV AND ELECTRICAL. . PROVIDE CORE DRILL AND PATHWAY FOR POWER, DATA AND AV AT LOCATION OF NEW MEDIAL TABLE LEG AND SMALL CONFERENCE ROOM TABLE. FIRESTOP PENETRATION TO MAINTAIN REQUIRED 2-HOUR FLOOR RATING. . PROVIDE AND INSTALL DECORATIVE PLAN WALL PANELS FROM FLOOR TO 48" A.F.F. INSTALL S|LH0UL||E, CLEAR TRIM IN ALL PROFILES AS REQUIRED FOR A COMPLETE AND FINISHED INSTALLATION. PL-6, SEE A-M-01 FOR MATERIALS SCHEDULE. GENERAL NOTES: 10. PATCH AND PREP ALL EXPOSED GWB WALL SURFACES TO RECEIVE NEW PAINT. 11. PROVIDE AND INSTALL CONTINUOUS WOOD TRAY RAIL. SEE DETAIL & ELEVATIONS A-K1-01. 12. PROVIDE AND INSTALL FABRIC WRAPPED ACOUSTICAL PANELS WITH SQUARE EDGE, BIAS TENSIONED SNAP-TEX TRACK AND MOUNTING SYSTEM, SEE ELEVATIONS A-M-01 13. EXISTING VERTICAL BLINDS TO REMAIN 14. PROVIDE AND INSTALL DIGITAL WALL CLOCK, MASTERCLOCK NTD24, RED DISPLAY COLOR, BLACK CASE. WALL MOUNT WITH FLUSH MOUNT BEZEL FM24N ON TOP OF FABRIC WRAPPED ACOUSTICAL PANELS. SEE ELEVATION ELEC.. & COMM.. . 15. RELOCATE AND/OR INSTALL NEW WALL MOUNTED FIRE SAFE|Y DEVICES IN ROOMS 309A. B & C. FIRE SAFE|Y DEVICES DEVICES AS REQUIRED B CODE. IN ROOMS 308 & 309 ARE EXISTING. LOCATE NEW AND EXISTING 16. PROVIDE POWER AND IP CONNECTION FOR DIGITAL CLOCK PER MS AV CONFERENCE ROOM GUIDELINES. 17. a. PROVIDE EMT CONDUITS AS REQUIRED FOR POWER, DATA AND A/V FROM FLUSH MOUNT FLOOR BOX TO CEILING PLENUM. EXTEND ALL CONDUITS UP TO 18" ABOVE SUSPENDED CEILING GRID. PROVIDE PULL STRING IN ALL RACEWAYS FOR A/V WIRING. PROVIDE FLUSH MOUNTED FLOOR BOX WITH (1) 120V/20A DUPLEX OUTLET. CONNECT POWER, NETWORK , ROUNDTABLE PHONE AND AV TO MEDIA � TO WALL-MOUNTED �_-_ _ --_-_^. b. PROVIDE PER NOTE 17a EXCEPT FLOOR BOX AND DATA A/V CONNECTION GO |O �ALL-�UUN|�U �L8_ | SCREEN. 18. SURFACE MOUNTED CONDUIT FOR EMERGENCY LIGHT AT WEST WALL OF ROOM 308 TO BE RELOCATED INSIDE WALL AT SAME LOCATION. 19. PROVIDE AND INSTALL 4-PLEX RECEPTACLE AT WEST WALL. INSTALL AT 36" AFF FOR USE AT TABLE. SEE A-F-01 FOR FURNTIURE PLACEMENT. 20. PROVIDE AND INSTALL MS STANDARD POWER AND DATA PACKS. VERIFY BUILDING STANDARD. 21. PROVIDE DUPLEX, DATA AND CAN AT LOCATION OF WALL MOUNTED FLAT PANEL DISPLAY. INSTALL AT 66" AFF, COORDINATE WITH AV. FURNITURE & SIGNAGE COORDINATE WITH WORKSPACE DEVELOPMENT 22. REMOVE EXISTING FURNITURE NOT REQUIRED FOR NEW LAYOUT, SALVAGE AS DIRECTED BY MICROSOFT. STORE EXISTING FURN|TURE, REQUIRED FOR NEW LAYOUT, FOR REUSE. 23. PROVIDE AND INSTALL MS STANDARD SIGNAGE FOR ROOMS 309 A-D; SEE A-F-01 FOR EXTENT OF WORK. A1.1 NAMEPLATE 5Y" WIDE. PROVIDE INSERT WITH ROOM NAMES AS NOTED ON PLANS. WALL TYPE LEGEND: ()KEY NOTES: I. I L_J EMERGENGY LIGHT FIXTURE DEMOLISHED WALLS LCSU LIGHTING CONTROL STATION NEW PARTIAL HEIGHT WALL TO SUSPENDED CEILING = � EXISTING WALL TO REMAIN �X|�||N6 �8LL |U �� ������ SYMBO LEGEND: 0��� ��ew�� QQ FOCAL POINT AVENUE A 2' AU0 0 9 4 FAVA-NS-1T5-1C-120-D-G1-WH W/ 1 13W T-8 4' FOCAL POINT AVENUE A FAVA-NS-1T5-1C-120-D-G1 W/ 1 28W T-8 2' FOCAL POINT AVENUE B LINEAR FLUORESCENT FAVB-PL-1T5-1C-12O-D(EC0-1O)-T1T-L835-YYH W/ 1 13W T-8 4' FOCAL POINT AVENUE B LINEAR FLUOESCENT F/A/B-PL-1T5-1C-120-D(EC0-10)-T1T-U535-VVH W/ 1 28W T-8 WALL SCONCE - COOPER METALUX BAU - 2 32W T8 LAMPS, WHITE HOUSING W/ BLACK TRIM. COORD. W/ MOTION SENSOR 2X4 RECESSED FLUORESCENT LIGHT FIXTURE EMERGENGY EXIT LIGHT FIXTURE O85/2m. � � ° \ \ » \ � K�8���������«« �~- � APPROVED 1 �� DEC 1 6 MB � uu° K :St------YC221C:;rnurfitOV 1. DEMO ALL LIGHT FIXTURES IN CONFERENCE ROOM 308 SALVAGE AS DIRECTED BY MICROSOFT. 2. PROVIDE AND INSTALL NEW LINEAR FLUORESCENT (FOCAL POINT AVENUE B) AND WALL WASH (FOCAL POINT AVENUE A) LIGHT FIXTURES AS SHOWN. PROVIDE ALL FIXTURES WITH LUTRON ECD-1O DIMMING UALLASCj._UNE.ECu-�|u^.Ba.�u\S| IS FOR EACH OF THE FOUR CHANNELS. FLUORESCENT LAMPS TO BE 3500k, 85 CRI. (AVENUE MS STANDARDS - NEW APPROVED FIXTURE PER RE&F) RELOCATE EXISTING EXIT - WATTS OR LESS. WATTS, REPLACE WITH NEW EXIT SIGN WITH INPUT POWER OF RELOCATE 2x4 RECESSED TROFFER LIGHT FIXTURE AS SHOWN. PROVIDE AND INSTALL WALL SCONCE LIGHT FIXTURE. MOUNT AT 6'-6" AFF TO CENTERLINE OF FIXTURE. CENTER ON WALL, REINFORCE WALL AS REQUIRED TO SUPPORT FIXTURE. PROVIDE AND INSTALL WALL SWITCH MOTION SENSOR. ��[TST0PPER PW-100. OCCUPANCY SENSORS SHALL BE COMMISSIONED AS REQUIRED BY SECTION 1513.7 OF THE 2006 ..`.,_- _ ..-'__ -- - - WASHINGTON ST ENERGY CODE. 7. PROVIDE AND INSTALL LUTRON GRAFIK-EYE 3000 SYSTEM WITH GRX-RS232 CONTROL _ INTERFACE | CONFERENCE ^ ROOW TO NORTH WALL ALL OFF. . COORDINATE LOCATION OF NEW CEILING MOUNTED PROJECTOR WITH AV VENDOR. PROVIDE SEISMIC MOUNTED FRAME ABOVE CEILING FOR PROJECTOR SEE A-M-01. PROVIDE DUPLEX & DATA IN CEILING FOR PROJECTOR. AV TO MEDIA TABLE AND CEILING MOUNTED PROJECTOR. COORDINATE TO INSTALL WIRE FROM PROJECTOR |u � . WITH AV & ELECTRICAL. 9. RELOCATE HVAC DIFFUSERS AND/OR RETURN AIR AS REQUIRED. ALL AIR RETURNS TO HAVE ACOUSTICAL BOOTS. 10. EXISTING SPRINKLERS ARE SHOWN. RELOCATE AND/OR PROVIDE NEW AT ROOMS 309 A, B & C. DESIGN BUILD CONTRACTOR TO OBTAIN ALL PERMITS, DESIGN AND INSTALL AS REQUIRED BY LOCAL CODES. 11. PROVIDE CEILING MOUNTED VISONIC 360 OCCUPANCY SENSOR AND MS STD CONFERENCE ROOM SPEAKERS PER CONFERENCE ROOM DESIGN GUIDELINES. VERIFY QUANTITY WITH MS AV. _OCCUP8NCY_SENSURS_Snm-L BE COMMISSIONED AS REQUIRED BY SECTION 1513.7 OF THE 2006 W 12. EXISTING EMERGENCY LIGHT FIXTURE TO REMAIN, RELOCATE EXISTING SURFACE MOUNTED CONDUIT INSIDE WALL. 13. PROVIDE 2'X2' CEILING GRID AND 2'X2' ACOUSTICAL CEILING TILE. ARMSTRONG OPTIMA #3354 14. RELOCATE EXISTING MOTORIZED PROJECTION SCREEN FROM TUKWILA 2, ROOM 180. INSTALL NEW WALL SWITCH. otriwo HVAC DIFFUSERS HVAC AIR RETURN HVAC AIR RETURN CEILING MID PROJECTOR CEILING MTD PA ~�,�.~�� �rc�^cn O CFU|NQ MTD CON� RM CS ---- -- ,� �� ��=^ucoc �rc�nu`� MOTION DETECTOR SPRINKLER HEAD SMOKE DETECTOR LIGHT SWITCH ARCHITECTURE ENGINEERING Design Team Design JOAN HATCHEL Drown AB Checked DOUGLAS A. DIEL Date 1 7-OR-OR Internal Project No. K-08-00445 M.S. Project No. P. 11540 ��� .~^,""` . ^^ 1O�O������� '""-°��"'"^"�'~`- Seattle, WA 98125 206.547.1940 p 206.547.8212 �����'' f ��^�. ��m . �� \&�/VV.=""[l=` Registration 3912 REGISTERED ARCHITECT L ikax STATE OF WASHINGTON Key Plan Bar Code RECEIVED CITY OF LA U���O ��70OR --- ~ ^.~- PERMIT CENTER Sheet Title THIRD N N 0�� 0 � �� N � �� ���� m m m m m m =°� � �� `*� �^~ ° ° ENLARGED S ��������U�� �-������KK � DRAWINGS � ����� �� �� �� K�� ��������� Sheet Title Amiam02 � 0 PARTIAL SECOND FLOOR FURNITURE PLAN SCALE: 1/4" = 1' - SF:48 J PAINTED STRIPES P-LAM WAINSCOT WALL BASE P' 1/4" = 1' - SF:48 0 1 2 4 8 PARTIAL THIRD FLOOR FURNITURE PLAN SCALE: HALLWAY ELEVATION SCALE: 1/2" = V - SF:24 0 1 2 4' 207 P 4 POPCORN WCHINE 311 P 1 3 0 / P 5 -1' • 207 309B . 1 / z \,/ v '' ',/ z \ ‘ ;', . ,.' A X. x ,/,,;/,,, , \/''' </. / '/ `,K / x ,/K/ x /./ >/' \/ x ,/ ‘,,71_4 I 6 / >,' ',.( / 7 :, K / / 7 ., 2 ,. \ 7 / „ / , 7, / .„ ./.., „,, ' x \ X / / , \ / „ /: ><" „/ ‘,/,/\ ‘, ,/ / \ ‘,, ' > , / / xv „,„ \ / / / //‘, , - - . - , \ /Y , / / \ /K ,, . ' ' , / /K/ / „,,/ / ,/ ../ , / - / / / ‘,: \ / ‘/ , „/ / >/ X '/x /, \ i / / \ 2 , / \ / '/ X/ .,%\/\/ /K T R 309C /\ / 306 309B P 5 I 309 P 5 m 5 I 1 I 305 I 309A I P U / /\ / / \ /\ \ z \ \ / ,./ S -- r 1 U P 6 304 r .<> S 308 P P 1 2 SEE A-M-01 ELEVATION FOR EXTENT OF PAINTING S T -G 304 U P _ II F T 315 I 314 rr U U' 16 N N N N N N U U GENERAL NOTES: ALL WALLS NOT NOTED IN AREA OF WORK TO BE P-5 • !Da AU Q 9 OM bp 8-5 12. RECEIVED CITY OF TUKWILA DEC 0 8 2008 PERMIT CENTER --1511111 mimm11111111•1•Ellr - --- TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 ------ 301111E1NEEmmemmon Revisions No. Date Description 12-1-08 CONSTRUCTION DRAWINGS 12-8-08 BUILDING PERMIT ARCHITECTURE ENGINEERING Design Drawn Dote 12-08-08 Internal Project No. M.S. Project No. P. 11540 3912 KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Design Team JOAN HATCH EL AB Checked DOUGLAS A. DIEL K-08-00445 Registration REGISTERED ARCHITECT %I.IGLAS A. DIEL STATE Of WASHINGTON - 1111111.6111111.11111Emumi Key Plan Bar Code Sheet Title FINISH PLANS PERMIT DRAWINGS 12-08-08 Sheet Title MATERIAL SCHEDULE ..® NO MAT'L MANUFACTURER EMEMIIIIMIIIIMECMill PROGRESSION, W403 F -1 FABRIC KNOLL COLOR #: 5 COLOR NAME: BEECH NO MAT'L MANUFACTURER STYLE #: FB -1 FORBO FORBO BULLETIN BOARD COLOR #: 2067 COLOR NAME: SAND NO MAT'L MANUFACTURER STYLE STYLE #: PL -1 P -LAM NEVAMAR - -- COLOR #: PR5002T COLOR NAME: PAPIER CACHE NO. MAT'L MANUFACTURER STYLE PL -2 P -LAM WILSONART - -- COLOR #: 10776 -60 COLOR NAME: KENSINGTON MAPLE NO. MAT'L MANUFACTURER STYLE STYLE #: PL -3 P -LAM NEVAMAR - -- COLOR #: ES2002T COLOR NAME: HONEYTONE ESSENCE NO. MAT'L MANUFACTURER STYLE STYLE #: PL -4 P -LAM MATCH EXISTING - -- COLOR #: BLACK COLOR NAME: NO. MAT'L MANUFACTURER STYLE STYLE #: PL--S NO P -LAM PIONITE . - -- COLOR #: MAT'L AB081 MANUFACTURER COLOR NAME: STYLE AZZURRA STYLE #: P L--6 P -L■M FORMICA COLOR #: 3505 -SR COLOR NAME: STORM SOLIDI NO. MAT'L MANUFACTURER STYLE STYLE #: WALLTALKERS KORO -RITE #KRP1 -05 COLOR #: 05 CO e A al ' y A Hggitl Wm", NO MAT'L TYPE z ,d' =a . WD -1 WOOD MAPLE, CLEAR PAINT SCHEDULE NO. MANUFACTURER COLOR COLOR NAME 131.1 P -1 BENJAMIN MOORE 1095 OAKWOOD MANOR P -2 BENJAMIN MOORE 1040 SPICE GOLD P -3 ICI #Al293 SMOKED TURQUOISE P -4 ICI #A0949 THYME P -5 ICI #A0941 MODERN MEDITATION P -6 ICI #A0896 HEATHROW P -7 ICI #A1929 PEPPER TREE P -8 ICI #A0292 CRANBERRY ZING I EXISTING POPCORN 7 -M -01 SIM. a a ") I- N M 1 0 0 o ADJ. SHELVES 1 ' I ,, r- r � r 1 1 1 I 1 j 1 li \ 1 ii J -M -01 DOOR TO HALLWAY CASEWORK DRAWER GLIDES INTERIORS: WHITE MELAMINE co 4 -0" DOOR TO HALLWAY IN OPEN POSITION P 2 WEST ELEVATION - CONFERENCE ROOM 308 SCALE:1 /2" = 1' -- SF:24 0 1' 2' 4 EAST ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 0 1 2 4 00.00 I / /77:77:;7, I\ /N, / x , » ( / /N _ / \/v/ y / /'/Z 10 / i / / X 18' -1" SITE VERIFY (6) EQUAL SECTIONS CHAIR RAIL @ ACOUSTICAL PANELS SCALE:6" = 1' - SF:2 0 3" 6" 7 y / x P / \ / 1" FABRIC WRAPPED ACOUSTICAL PANEL F PROVIDE ANCHOR BOLTS AS REQUIRED SOLID STOCK WOOD WD 1 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD FABRIC WRAPPED ACOUSTICAL PANEL SPECIFICATION: COMPOSITE BOARD; Y2" USG PERFORATED MICORE LAMINATED TO %8" 4.5 lb SEMI RIGID FIBERGLASS. PANELS TO BE SQUARE EDGE, BIAS TENSIONED SNAP -TEX TRACK IN THE APPROPRIATE DEPTH FOR APPLICATION. WHERE FABRIC PANELS ARE TO BE INSTALLED AT WALLS WITH CASEWORK BACKSPLASH, USE THINNER FIBERGLASS AS REQUIRED TO OBTAIN 3 /4" OVERALL THICKNESS OEC 14' -9" i >: N/ LENGTH OF FABRIC, ti / ✓ u SCALE:6" = 1 - SF:2 0 3 " P 2 7 P 0 9 RAIL @ WALL COVERING /DOOR TO 309A 6 " ACOUSTICAL FABRIC PANELS F P LAM COUNTER, RETURN BACKSPLASH BOTH SIDES PL 2 P -LAM BASE CABINETS WITH ADJUSTABLE SHELF PL 5 B WALL TALKERS VINYL WALL COVERING INSTALLED OVER EXISTING VINYL W S.S. FLAT BAR — A" THICK 1 N/EASED EDGES, ROUTE INTO WOOD, STOP 2" BEFORE EACH END. SOLID STOCK WOOD 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD 1 PROVIDE ANCHOR BOLTS AS REQUIRED NEW Y4" GWB NEW DIGITAL CLOCK EXISTING EMERGENCY LIGHT ACOUSTICAL FABRIC PANELS. RUN WIDTH OF FABRIC HORIZONTALLY r LIGHTING CONTROL EXISTING THERMOSTAT SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL EXISTING BASE KI RECYCLE UNITS WITH MAPLE TOP sic -M -01 5� MAIL SLOTS (7) REQ'D - OFFICE SUPPLIES PL MAIL i 1 1 - MAIL EXPRESS ;' EXPRESS 13 "W I \ i 13 "W 11 "H ' l i 11 "H 18 "D ) 18 "D ALIGN FORBO� TACKBOARD OPEN FOR PAPER STORAGE SUPPORTS N 0 N r) N N N 0 SCALE: 1" = 1' - SF:12 0 6"" 1' 2 2' -6" 0 6" 1 2 CASEWORK ELEVATION - COPY ROOM 207A 3' -6" PROJECTOR MOUNTING SUPERSTRUCTURE SCALE:1 " = 1' - SF:12 NEW SEAM CUT CLNG TILE TO FIT AROUND POST. CONCEAL CUT EDGE WITH CEILING GROMMET -EXISTING `,- SEAM NEW 'WALL TALKERS' VINYL WALL COVERING W 1 1 NORTH ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 OL. -l-1, �" - -._� 4' ADJ. SHELVES DUPLEX RECEPTACLE G 42 "AFF COUNTER TOP PL 4 OPEN ADJUSTABLE SHELVING PL WALL BASE B 1/2"s THREADED ROD TO STRUCTURE ABOVE, TYP. OF 4 SEISMIC BRACE UNISTRUT TWO DIRECTIONS WITH METAL STUDS 1 -5/8" UNISTRUT 96" LONG (x2) a: 1 5/8" UNISTRUT 12" LONG WITH SPRING NUT TO ALLOW FUTURE Q w J ADJUSTMENT. U rn ` METAL POST EXTENDS BELOW SUSPENDED CEILING, ATTACH TO MOUNTING PLATE, COORD. DIA. AND LENGTH OF POST WITH DIV. 27 WORK. PAINT POST FLAT BLACK. PROJECTOR MOUNTING PLATE TO COORDINATE WITH PROJECTOR MODEL TO BE INSTALLED. 2' -1" 1' -7" CASEWORK SECTION SCALE: 1 " = 1' - SF:12 37' -0" SITE VERIFY 1' -2" CLEAR I ..�J 2, 0 In 1' -5" ANGLE BRACE TOP OF WALL TO STRUCT. PER IBC REQUIREMENTS ANCHOR 8' 0.0. MAX. MTL. EDGE BEAD 0 6 "" 1' 2 NON- COMBUSTABLE BLOCKING - BLACK TOP RUNNER ANCHOR MAX. 4' O.C. 2-1/2" - 25 GA. MTL. STUDS MIN. 2' O.C. W/5/8" TYPE "X" GWB EA. SIDE MAX. HEIGHT 10` -0" CONT. MTL. RUNNER ANCHORED TO FLOOR, MAX. 4' O.C. WALL BASE, TYP. EXISTING FINISHED FLOOR ----BACKER ROD & CAULK 3' -0" 11 WALL SECTION - NON - STRUCTURAL SCALE:3" = 1' •- SF:4 0 6" 1' 1 ' -5" EXIST. SUSP. CLG. 10' -0" A.F.F. CASEWORK ELEVATION - BREAKRM. SCALE: 1" = 1' - SF:12 FREESTANDING COUNTER PL 4 TWO DRAWERS WITH HEAVY DUTY DRAWER GLIDES 7--FINISHED BLACK PLAM BASE. RUBBER BASE BY G.C. B L 4" P -LAM EDGE, RN SPLASH IDES PL 2 W 2' -1y4" O 0 a 0 O 0 O 0 a 0 ADJ. 0 SHELVES 0 0 0 0 0 0 1 z X ACOUSTICAL PANE 1 -1/ SELF RETU BAC K AT S 0 SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL AND S.S. BAR EXISTING BASE CASEWORK SECTION SCALE: 1" = 1' - SF:12 CODE E°V 1PLIAt APPROVE {' -00445 � 1 li M C1 Proj Nn P. 11540 AU Q 9 #100 TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 Revisions No. Date 12 -1 -08 12 -8 -08 ARCHITECTURE ENGINEERING Design Team Design JOAN HATCH EL Drawn AB gtlm *-0. P. 11540 ' w• 1 ��+.� Uri Description RECEIVED CITY OF TUKWILA Ike 0 8 2008 PERMIT CENTER CONSTRUCTION DRAWINGS BUILDING PERMIT KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Checked DOUGLAS A. DIEL Date \ 12 -08 -08 Internal Project No. Registration 3312 REGISTERED ARCHITECT /7 DOUGLAS A. 01E1 STATE Of WASHINGTON Key Plan Bar Code Sheet Title DETAILS PERMIT DRAWINGS 12 -08 -08 Sheet Title AM-01 EXISTING POPCORN 7 -M -01 SIM. N -M -01 DOOR TO HALLWAY CASEWORK DRAWER GLIDES INTERIORS: WHITE MELAMINE co 4 -0" DOOR TO HALLWAY IN OPEN POSITION P 2 WEST ELEVATION - CONFERENCE ROOM 308 SCALE:1 /2" = 1' -- SF:24 0 1' 2' 4 EAST ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 0 1 2 4 00.00 I / /77:77:;7, I\ /N, / x , » ( / /N _ / \/v/ y / /'/Z 10 / i / / X 18' -1" SITE VERIFY (6) EQUAL SECTIONS CHAIR RAIL @ ACOUSTICAL PANELS SCALE:6" = 1' - SF:2 0 3" 6" 7 y / x P / \ / 1" FABRIC WRAPPED ACOUSTICAL PANEL F PROVIDE ANCHOR BOLTS AS REQUIRED SOLID STOCK WOOD WD 1 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD FABRIC WRAPPED ACOUSTICAL PANEL SPECIFICATION: COMPOSITE BOARD; Y2" USG PERFORATED MICORE LAMINATED TO %8" 4.5 lb SEMI RIGID FIBERGLASS. PANELS TO BE SQUARE EDGE, BIAS TENSIONED SNAP -TEX TRACK IN THE APPROPRIATE DEPTH FOR APPLICATION. WHERE FABRIC PANELS ARE TO BE INSTALLED AT WALLS WITH CASEWORK BACKSPLASH, USE THINNER FIBERGLASS AS REQUIRED TO OBTAIN 3 /4" OVERALL THICKNESS OEC 14' -9" i >: N/ LENGTH OF FABRIC, ti / ✓ u SCALE:6" = 1 - SF:2 0 3 " P 2 7 P 0 9 RAIL @ WALL COVERING /DOOR TO 309A 6 " ACOUSTICAL FABRIC PANELS F P LAM COUNTER, RETURN BACKSPLASH BOTH SIDES PL 2 P -LAM BASE CABINETS WITH ADJUSTABLE SHELF PL 5 B WALL TALKERS VINYL WALL COVERING INSTALLED OVER EXISTING VINYL W S.S. FLAT BAR — A" THICK 1 N/EASED EDGES, ROUTE INTO WOOD, STOP 2" BEFORE EACH END. SOLID STOCK WOOD 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD 1 PROVIDE ANCHOR BOLTS AS REQUIRED NEW Y4" GWB NEW DIGITAL CLOCK EXISTING EMERGENCY LIGHT ACOUSTICAL FABRIC PANELS. RUN WIDTH OF FABRIC HORIZONTALLY r LIGHTING CONTROL EXISTING THERMOSTAT SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL EXISTING BASE KI RECYCLE UNITS WITH MAPLE TOP sic -M -01 5� MAIL SLOTS (7) REQ'D - OFFICE SUPPLIES PL MAIL i 1 1 - MAIL EXPRESS ;' EXPRESS 13 "W I \ i 13 "W 11 "H ' l i 11 "H 18 "D ) 18 "D ALIGN FORBO� TACKBOARD OPEN FOR PAPER STORAGE SUPPORTS N 0 N r) N N N 0 SCALE: 1" = 1' - SF:12 0 6"" 1' 2 2' -6" 0 6" 1 2 CASEWORK ELEVATION - COPY ROOM 207A 3' -6" PROJECTOR MOUNTING SUPERSTRUCTURE SCALE:1 " = 1' - SF:12 NEW SEAM CUT CLNG TILE TO FIT AROUND POST. CONCEAL CUT EDGE WITH CEILING GROMMET -EXISTING `,- SEAM NEW 'WALL TALKERS' VINYL WALL COVERING W 1 1 NORTH ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 OL. -l-1, �" - -._� 4' ADJ. SHELVES DUPLEX RECEPTACLE G 42 "AFF COUNTER TOP PL 4 OPEN ADJUSTABLE SHELVING PL WALL BASE B 1/2"s THREADED ROD TO STRUCTURE ABOVE, TYP. OF 4 SEISMIC BRACE UNISTRUT TWO DIRECTIONS WITH METAL STUDS 1 -5/8" UNISTRUT 96" LONG (x2) a: 1 5/8" UNISTRUT 12" LONG WITH SPRING NUT TO ALLOW FUTURE Q w J ADJUSTMENT. U rn ` METAL POST EXTENDS BELOW SUSPENDED CEILING, ATTACH TO MOUNTING PLATE, COORD. DIA. AND LENGTH OF POST WITH DIV. 27 WORK. PAINT POST FLAT BLACK. PROJECTOR MOUNTING PLATE TO COORDINATE WITH PROJECTOR MODEL TO BE INSTALLED. 2' -1" 1' -7" CASEWORK SECTION SCALE: 1 " = 1' - SF:12 37' -0" SITE VERIFY 1' -2" CLEAR I ..�J 2, 0 In 1' -5" ANGLE BRACE TOP OF WALL TO STRUCT. PER IBC REQUIREMENTS ANCHOR 8' 0.0. MAX. MTL. EDGE BEAD 0 6 "" 1' 2 NON- COMBUSTABLE BLOCKING - BLACK TOP RUNNER ANCHOR MAX. 4' O.C. 2-1/2" - 25 GA. MTL. STUDS MIN. 2' O.C. W/5/8" TYPE "X" GWB EA. SIDE MAX. HEIGHT 10` -0" CONT. MTL. RUNNER ANCHORED TO FLOOR, MAX. 4' O.C. WALL BASE, TYP. EXISTING FINISHED FLOOR ----BACKER ROD & CAULK 3' -0" 11 WALL SECTION - NON - STRUCTURAL SCALE:3" = 1' •- SF:4 0 6" 1' 1 ' -5" EXIST. SUSP. CLG. 10' -0" A.F.F. CASEWORK ELEVATION - BREAKRM. SCALE: 1" = 1' - SF:12 FREESTANDING COUNTER PL 4 TWO DRAWERS WITH HEAVY DUTY DRAWER GLIDES 7--FINISHED BLACK PLAM BASE. RUBBER BASE BY G.C. B L 4" P -LAM EDGE, RN SPLASH IDES PL 2 W 2' -1y4" O 0 a 0 O 0 O 0 a 0 ADJ. 0 SHELVES 0 0 0 0 0 0 1 z X ACOUSTICAL PANE 1 -1/ SELF RETU BAC K AT S 0 SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL AND S.S. BAR EXISTING BASE CASEWORK SECTION SCALE: 1" = 1' - SF:12 CODE E°V 1PLIAt APPROVE {' -00445 � 1 li M C1 Proj Nn P. 11540 AU Q 9 #100 TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 Revisions No. Date 12 -1 -08 12 -8 -08 ARCHITECTURE ENGINEERING Design Team Design JOAN HATCH EL Drawn AB gtlm *-0. P. 11540 ' w• 1 ��+.� Uri Description RECEIVED CITY OF TUKWILA Ike 0 8 2008 PERMIT CENTER CONSTRUCTION DRAWINGS BUILDING PERMIT KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Checked DOUGLAS A. DIEL Date \ 12 -08 -08 Internal Project No. Registration 3312 REGISTERED ARCHITECT /7 DOUGLAS A. 01E1 STATE Of WASHINGTON Key Plan Bar Code Sheet Title DETAILS PERMIT DRAWINGS 12 -08 -08 Sheet Title AM-01 EXISTING POPCORN 7 -M -01 SIM. ADJ. SHELVES \ -M -01 DOOR TO HALLWAY CASEWORK DRAWER GLIDES INTERIORS: WHITE MELAMINE co 4 -0" DOOR TO HALLWAY IN OPEN POSITION P 2 WEST ELEVATION - CONFERENCE ROOM 308 SCALE:1 /2" = 1' -- SF:24 0 1' 2' 4 EAST ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 0 1 2 4 00.00 I / /77:77:;7, I\ /N, / x , » ( / /N _ / \/v/ y / /'/Z 10 / i / / X 18' -1" SITE VERIFY (6) EQUAL SECTIONS CHAIR RAIL @ ACOUSTICAL PANELS SCALE:6" = 1' - SF:2 0 3" 6" 7 y / x P / \ / 1" FABRIC WRAPPED ACOUSTICAL PANEL F PROVIDE ANCHOR BOLTS AS REQUIRED SOLID STOCK WOOD WD 1 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD FABRIC WRAPPED ACOUSTICAL PANEL SPECIFICATION: COMPOSITE BOARD; Y2" USG PERFORATED MICORE LAMINATED TO %8" 4.5 lb SEMI RIGID FIBERGLASS. PANELS TO BE SQUARE EDGE, BIAS TENSIONED SNAP -TEX TRACK IN THE APPROPRIATE DEPTH FOR APPLICATION. WHERE FABRIC PANELS ARE TO BE INSTALLED AT WALLS WITH CASEWORK BACKSPLASH, USE THINNER FIBERGLASS AS REQUIRED TO OBTAIN 3 /4" OVERALL THICKNESS OEC 14' -9" i >: N/ LENGTH OF FABRIC, ti / ✓ u SCALE:6" = 1 - SF:2 0 3 " P 2 7 P 0 9 RAIL @ WALL COVERING /DOOR TO 309A 6 " ACOUSTICAL FABRIC PANELS F P LAM COUNTER, RETURN BACKSPLASH BOTH SIDES PL 2 P -LAM BASE CABINETS WITH ADJUSTABLE SHELF PL 5 B WALL TALKERS VINYL WALL COVERING INSTALLED OVER EXISTING VINYL W S.S. FLAT BAR — A" THICK 1 N/EASED EDGES, ROUTE INTO WOOD, STOP 2" BEFORE EACH END. SOLID STOCK WOOD 2 "x2" CLEAR ANODIZED ALUMINUM ANGLE SOLID STOCK WOOD WD 1 PROVIDE ANCHOR BOLTS AS REQUIRED NEW Y4" GWB NEW DIGITAL CLOCK EXISTING EMERGENCY LIGHT ACOUSTICAL FABRIC PANELS. RUN WIDTH OF FABRIC HORIZONTALLY r LIGHTING CONTROL EXISTING THERMOSTAT SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL EXISTING BASE KI RECYCLE UNITS WITH MAPLE TOP sic -M -01 5� MAIL SLOTS (7) REQ'D - OFFICE SUPPLIES PL MAIL i 1 1 - MAIL EXPRESS ;' EXPRESS 13 "W I \ i 13 "W 11 "H ' l i 11 "H 18 "D ) 18 "D ALIGN FORBO� TACKBOARD OPEN FOR PAPER STORAGE SUPPORTS N 0 N r) N N N 0 SCALE: 1" = 1' - SF:12 0 6"" 1' 2 2' -6" 0 6" 1 2 CASEWORK ELEVATION - COPY ROOM 207A 3' -6" PROJECTOR MOUNTING SUPERSTRUCTURE SCALE:1 " = 1' - SF:12 NEW SEAM CUT CLNG TILE TO FIT AROUND POST. CONCEAL CUT EDGE WITH CEILING GROMMET -EXISTING `,- SEAM NEW 'WALL TALKERS' VINYL WALL COVERING W 1 1 NORTH ELEVATION - CONFERENCE ROOM 308 SCALE: 1 /2" = 1' - SF:24 OL. -l-1, �" - -._� 4' ADJ. SHELVES DUPLEX RECEPTACLE G 42 "AFF COUNTER TOP PL 4 OPEN ADJUSTABLE SHELVING PL WALL BASE B 1/2"s THREADED ROD TO STRUCTURE ABOVE, TYP. OF 4 SEISMIC BRACE UNISTRUT TWO DIRECTIONS WITH METAL STUDS 1 -5/8" UNISTRUT 96" LONG (x2) a: 1 5/8" UNISTRUT 12" LONG WITH SPRING NUT TO ALLOW FUTURE Q w J ADJUSTMENT. U rn ` METAL POST EXTENDS BELOW SUSPENDED CEILING, ATTACH TO MOUNTING PLATE, COORD. DIA. AND LENGTH OF POST WITH DIV. 27 WORK. PAINT POST FLAT BLACK. PROJECTOR MOUNTING PLATE TO COORDINATE WITH PROJECTOR MODEL TO BE INSTALLED. 2' -1" 1' -7" CASEWORK SECTION SCALE: 1 " = 1' - SF:12 37' -0" SITE VERIFY 1' -2" CLEAR I ..�J 2, 0 In 1' -5" ANGLE BRACE TOP OF WALL TO STRUCT. PER IBC REQUIREMENTS ANCHOR 8' 0.0. MAX. MTL. EDGE BEAD 0 6 "" 1' 2 NON- COMBUSTABLE BLOCKING - BLACK TOP RUNNER ANCHOR MAX. 4' O.C. 2-1/2" - 25 GA. MTL. STUDS MIN. 2' O.C. W/5/8" TYPE "X" GWB EA. SIDE MAX. HEIGHT 10` -0" CONT. MTL. RUNNER ANCHORED TO FLOOR, MAX. 4' O.C. WALL BASE, TYP. EXISTING FINISHED FLOOR ----BACKER ROD & CAULK 3' -0" 11 WALL SECTION - NON - STRUCTURAL SCALE:3" = 1' •- SF:4 0 6" 1' 1 ' -5" EXIST. SUSP. CLG. 10' -0" A.F.F. CASEWORK ELEVATION - BREAKRM. SCALE: 1" = 1' - SF:12 FREESTANDING COUNTER PL 4 TWO DRAWERS WITH HEAVY DUTY DRAWER GLIDES 7--FINISHED BLACK PLAM BASE. RUBBER BASE BY G.C. B L 4" P -LAM EDGE, RN SPLASH IDES PL 2 W 2' -1y4" O 0 a 0 O 0 O 0 a 0 ADJ. 0 SHELVES 0 0 0 0 0 0 1 z X ACOUSTICAL PANE 1 -1/ SELF RETU BAC K AT S 0 SOLID STOCK WOOD CHAIR RAIL WITH SOLID STOCK WOOD TRAY RAIL AND S.S. BAR EXISTING BASE CASEWORK SECTION SCALE: 1" = 1' - SF:12 CODE E°V 1PLIAt APPROVE {' -00445 � 1 li M C1 Proj Nn P. 11540 AU Q 9 #100 TUKWILA 5 3355 S. 120th PLACE TUKWILA, WA 98168 Revisions No. Date 12 -1 -08 12 -8 -08 ARCHITECTURE ENGINEERING Design Team Design JOAN HATCH EL Drawn AB gtlm *-0. P. 11540 ' w• 1 ��+.� Uri Description RECEIVED CITY OF TUKWILA Ike 0 8 2008 PERMIT CENTER CONSTRUCTION DRAWINGS BUILDING PERMIT KDW, PS 10202 5th Ave NE Seattle, WA 98125 206.547.1940 p 206.547.8212 f www.kdw.net Checked DOUGLAS A. DIEL Date \ 12 -08 -08 Internal Project No. Registration 3312 REGISTERED ARCHITECT /7 DOUGLAS A. 01E1 STATE Of WASHINGTON Key Plan Bar Code Sheet Title DETAILS PERMIT DRAWINGS 12 -08 -08 Sheet Title AM-01