Loading...
HomeMy WebLinkAboutPermit D08-518 - FATIGUE TECHNOLOGY - STORAGE RACKSFATIGUE TECHNOLOGY 401 ANDOVER PK E D08 -518 Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Tenant: Name: FATIGUE TECHNOLOGY INC Address: 401 ANDOVER PK E , TUKWILA WA Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST , RENTON WA 98057 Phone: 206 818 -4488 CitAIK Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Owner: Name: GIBSON PROPERTIES L L C Address: PO BOX 88909 , SEATTLE WA 98138 -2909 98138 Phone: DEVELOPMENT PERMIT Permit Number: D08 - 518 Issue Date: 01/05/2009 Permit Expires On: 07/04/2009 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET , RENTON, WA 98055 Phone: 206 255 -0500 Contractor License No: NORTHWH275JF Expiration Date: 10/09/2009 DESCRIPTION OF WORK: INSTALLATION OF NEW AND USED RACKING FOR STORAGE OF SMALL STEEL PARTS STOCK. Value of Construction: $0.00 Fees Collected: $99.05 Type of Fire Protection: SPRINIC,ER/AFA International Building Code Edition: 2006 Type of Construction: Occupancy per IBC: doc: IBC -10/06 * * continued on next page ** D08 -518 Printed: 01 -05 -2009 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City 4 Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Signature: Print Name: .q doc: IBC -10/06 - ,Yr)„,a Permit Number: D08 - 518 Issue Date: 01/05/2009 Permit Expires On: 07/04/2009 Date: l`‘S '00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance o •_•rk. I am authorized to sign and obtain this development permit. Date: l/ ° This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D08 -518 Printed: 01 -05 -2009 Parcel No.: 0223400050 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 401 ANDOVER PK E TUKW FATIGUE TECHNOLOGY INC 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: D08 -518 ISSUED 12/23/2008 01/05/2009 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. D08 -518 Printed: 01 -05 -2009 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: }4 s Off' s an • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond -10/06 D08 -518 Date: //570 ordinances governing or local laws regulating Printed: 01 -05 -2009 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: t www. ci. tukwila. wa. us SITE LOCATION Site Address: y01 4r140Ver Park . Tenant Name: Fa l Q to Property Owners Name: F�1 1 i (iii C Mailing Address: 401 ,'orir 1 Name: /' 1ke ...S sCr'1 Mailing Address:1 /00 ..S• W• 7 Contact Person:' k _S;r-e rt S c E -Mail Address: t l SC6-7 6 h CA4A S • (0 rx Contractor Registration Number: Al c H R.. . `� ) Mailing Address: Contact Person: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** it C E -Mail Address: - Q \Applications\Forms- Applications On Line \3 -2006 - Permit Application.doc Revised. 9 -2006 bh Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) King Co Assessor's Tax No.: Suite Number: Floor: / New Tenant: ❑ Yes [B`No City 01-2) Do ;D State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: .-0G-�ls _ i(Yeg c`fOs7 City State Zip E -Mail Address: Vfl S O r rz✓t S V) w S et_v,n.1 Fax Number: 4 )-e- 6 9 %/C. GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name:,&Jor - +t ■ U 0 n./1 /1 �y vim s Mailing Address: I t O() 5. Af 7" S T J 'C.c?rtie -p-1 NO S 7 City State Zip Day Telephone: 6 " t. - Yy f a' L i t Fax Number: ( S z9' (j `i y% Expiration Date: /O 7? / . c 9 ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: Mailing Address: cit Contact Person: Day Telephone: E- al Address: Fax Number: State Zip ENGINEER OF RECORD— All plans must be wet stamped by Engineer of Record Company Name: R/A Le 'Dos . w G=+ 6_ C4 Cit State Zip // /'''J t�n 4N/ rth Day Telephone: Err ?171c 3gio lI Fax Number: erg a'YQ -P873 Page 1 of 6 [ PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ I a 06 t 00 Existing Building Valuation: $ Scope of Work (please provide detailed information): 211 S ict (I ci c" c ) /1 rz ' v -10 t t /'k Ckv -C. j 4.4 .5;144 /� Sf`e.�. r r s" S> C (C'. � � ,Fe 2 <n ' 4 (Gad el P G tv . I / n y s Will there be new rack storage? 'Yes ❑.. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Provide All Building Areas in Square Footage Below Q:\Applicationaorms- Applications On Line \3.2006 - Permit Application.doc Revised: 9 -2006 bh Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. cn Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes le—No If "yes ", explain: FIRE PROT CTION /HAZARDOUS MATERIALS: Sprinklers Q' Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Iti+."' No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IB Type Occupancy IB of per l Floor y 22 Floor 3 Floor Floors thru I Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck [ PERMIT INFORMATION - 206- 431 -3670 Valuation of Project (contractor's bid price): $ I a 06 t 00 Existing Building Valuation: $ Scope of Work (please provide detailed information): 211 S ict (I ci c" c ) /1 rz ' v -10 t t /'k Ckv -C. j 4.4 .5;144 /� Sf`e.�. r r s" S> C (C'. � � ,Fe 2 <n ' 4 (Gad el P G tv . I / n y s Will there be new rack storage? 'Yes ❑.. No If yes, a separate permit and plan submittal will be required. PLANNING DIVISION: Provide All Building Areas in Square Footage Below Q:\Applicationaorms- Applications On Line \3.2006 - Permit Application.doc Revised: 9 -2006 bh Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. cn Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes le—No If "yes ", explain: FIRE PROT CTION /HAZARDOUS MATERIALS: Sprinklers Q' Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Iti+."' No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Date Application Accepted: � A Date Application Expires: Staff Initials: � 1 PERMIT APPLICATION NOTES — Applicable to all permits in this, application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED ; T: Signature: Print Name: Mailing Address: 1/00 S. w 71s S Qi\ApplicationsWorms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: /49 6/occ-- Day Telephone: m /8 — c- ' k City State Zip Page 6 of 6 Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Applicant: FATIGUE TECHNOLOGY INC Receipt No.: R09 -00002 Payee: MIKE SORENSON ACCOUNT ITEM LIST: Description BUILDING - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Initials: WER Payment Date: 01/05/2009 01:57 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7168 61.80 Account Code Current Pmts 000/322.100 000/386.904 RECEIPT Permit Number: D08 -518 Status: APPROVED Applied Date: 12/23/2008 Issue Date: Payment Amount: $61.80 57.30 4.50 Total: $61.80 1110 01/05 9707 TOTAL 172.80 doc: Receipt -06 Printed: 01 -05 -2009 Parcel No.: 0223400050 Address: 401 ANDOVER PK E TUKW Suite No: Applicant: FATIGUE TECHNOLOGY INC Receipt No.: R08 -03962 Payee: MICHAEL J. SORENSON ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Initials: JEM Payment Date: 12/23/2008 11:41 AM User ID: 1165 Balance: $61.80 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7164 37.25 Account Code Current Pmts 000/345.830 37.25 Total: $37.25 • Permit Number: D08 -518 Status: PENDING Applied Date: 12/23/2008 Issue Date: Payment Amount: $37.25 0689 12/23 9716 TOTAL 37.25 r1nr.: RarAint -f1R Printari• 12 -23 -7008 Project: F4T GAL' � 6 U1 Type of 1 lion: I f N >f\ ( Address: 9 01P w,✓ Pe F Date Called: Special Instructions: Date Wanted: Cro-' '-- 1 c a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3 TA Approved per applicable codes. El Corrections required prior to approval. COMMENTS: v w ; -t C l 14 ' /F#sri Dave: 0.00 REINSPECTION FED REQUIED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Su to 100. Call to schedule reinspection. ceipt No.: 'Date: Project: �„_ F AT 'G �£ 1 Type of Ispection: - r�L1 t )A/?1' 1 e Pe ill 01 - r Lt 6 Address: . -. , -G - 1 -( uv 4 e PIL Date Called: Special Instructions: T2 1 �c.., J 1 _ Date Wanted: 1 - 2 p -o trrim.. p.m. Requester: 4.4.6 za: /h 7 : -i iolv 1 ./ea Phone 20 - ES -L( ry a COMMENTS: / )A/?1' 1 e Pe ill 01 - r Lt 6 Aiecci ( 448 Aso. � ,,' e , ("owPi rf..., d / To ,?T if -, L ?,') / /e % %e // Ar7 - 4.4.6 za: /h 7 : -i iolv 1 ./ea Inspe or: / ! e , A • Date: 2 8 ..., re 79, INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved. per applicable codes. Date: bo -see PERMIT NO. VW (206)431 3670 Corrections required prior to approval. 60.00 REINSPECT! N FEE RE IRED. Prior to inspection, e must be paid at 6300 Southce ter Blv , Suite 100. Call to schedule einspection. r eceiPt No.: t Project: fa-c\ 00 - t. l t: «rte o L-0 �y Type of Inspection: Address: y u A-I9 C Suite # Contact Person: M : 5L ta Special Instructions: Phone No Needs Shift Inspection: Sprinklers; Fire Alai: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER cak Facr Tukwila_ ;W�_ QR1RR 206 -575 -4407 ,,,V per applicable codes. COMMENTS: SAC V N Pk QI 6J-01C4t.. Mint N to eet,042 ( ;vT , weto Tilt, Date: 1 /77 /0 / Fi : I .00 REINSPECTION FEE REQUIRED. You will receive an invoice from fi'l City of Tukwila Finance Department. Call to schedule a reinspection. Inspector. 4 Q &a I S Word /Inspectiion Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS Corrections required prior to approval. Hrs.. T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry A s p h a l t Roofing P i l i n g S t e e l S o i l s W o o d June 25, 2009 File: 09 -123 City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Fatigue Technology Address: 401 Andover Park E. Permit No.: D08 -518 This is to advise you that special inspections are completed on the above referenced project. The following inspections were required and copies of those reports have already been sent. 1 Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Kimberle Anderson President `JUN 2 9 2009 i cc: NorthWest Handing Systems, Inc. -Mike Sorenson, Rob Prather A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY Tel: (425) 881 -5812 Fax (425) 881 -5441 • 7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 n FEB 2 7 1009 COMMUNITY DEVELOPr1E T A.A.R. Testing Laboratory, Inc. 7126 180th Ave.N.E., Park 180, Suite C101, Redmond, WA 98052 Phone 425.881.5812 Fax 425.881.5441 Client: NorthWest Handling Systems, Inc. 1100 SW 7th St. Renton, WA 98055 -2939 Contact: Rob Prather Inspection Performed: Date: 1/27/2009 Distribution: Distribute Client Distribute Engineer _ i %• Distribute Municipality Distribute Architect Field Report Project Number: Permit #: Project Name: Address: Time: 1:35:00 PM Verified anchors to be Hilti KB -TZ 1/2 "x4 1/2" wedge type anchors. Verified holes to be blown to a clean state. Verified 3 1/4" embedment depth into existing slab. Torque was confirmed to meet or exceed manufacturer's recommendation of 40 ft/lbs with calibrated wrench #132. All work found completed in conformance with approved plans, manufacturer's recommendations and ESR #1917. Areas inspected as noted for above permit on FT -2 of drawings. Distribute Contractor Distribute Owner Distribute Other Distribute Other Report #: 49378 09 -123 D08 -518 Fatigue Technology Inc. 401 Andover Park E. Temperature: Inspector: Chandler, Loren Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden SITE ADDRESS: TENANT NAME: DATE: APPLICANT: e Material Handling Experts 401 Andover Park E. Fatigue Technology Inc. December 16, 2008 Mike Sorenson / (206) 818 -4488 5. Commodities stored in racks: Small parts of steel stock. 7. Smoke and heat vents are in place. 8. Building exits indicated on attached drawings. f Le COQ Prt c 1100 SW 7th St Renton, WA 98055 (425) 255-0500 ph (425) 228-6946 fax ATTN: BUILDING DEPARTMENT AND FIRE DEPARTMENT RACK INFORMATION SUPPLEMENT �e�lcde��. �-�� CODE COMPLLNCE APPP®1 D JAN 0'4 [uud 0I Of Tukwila JEDING DIVISION 1. Load application and rack configuration drawings attached. 2. Attached plans and engineering detail the rack locations, dimensions, and specifications. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 6. Sprinkler System Information: .60 GPM / 2500 square feet. Sprinkler head temperature: 165 degrees. RECEIVED CITY OF TUKWILA DEC 2 3 2008 PERMIT CENTER POg BY G. OHANIAN DATE . 12 -10 -08 SUBJECT STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FATIGUE TECHNOLOGY INC. 401 ANDOVER PARK EAST TUKWILA, WA. 98188 PER IBC 2006 EDITION STORAGE RACKS CAPACITY: 2000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -13850 RAdK DEOI(N & ENOINEERINGI do. 412 WEBT BROADWAY, QUITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 SHEET NO 1 JOB NO. RD - 13850 ,,,oprPke COPY EXPIRES 12 - - �L�IybC6� 6'ly6�t DROVE CE JAN 0 2 2008 aty0f Tukwila - 3UILDING DIVISION RECEIVED CITY OF TUKWILA DEC 2 3 2008 PERMIT CENTER BY , G. OHANIAN DATE. 12 -10 -08 SUBJECT SEISMIC DESIGN _ S xl p V- Rx1.4 WORKING STRESS 108" & 54" { FRONT VIEW BEAM M= 108 "x1.2K =16 K 8 S 33 "K= .49 <.77 _ 5xWxL 3 108 �, 384x1 xE -'35 < 180 = .60 So =.94 (USGS WEB SITE, "SITE CLASS D ") W =.2p.( 5.3Lif. 5.5 K V _ .94x 1x5.3 = 59 K LONGR. 6x1.4 • v = .94x 1x5.3 = 89 K TRANS. 4x1.4 • RAdK DENIG N & EN(4INEERIN( CO. 412 WEOT BROADWAY, QUITE #204 GLENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 N N N LO IN In 2000 #/ LEVEL +25% IMPACT LOAD 1200 #/ BEAM M _ .59 K x24" -7 'K COL 2 I =1.63 S=.77 F Y 55 KSI. IBC 2006 ASCE 7 -05 (SEC. 15.5.3) PER RMI SPECS. Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4536 Longitude = — 122.2501 Spectral Response Accelerations SMs and SM1 SMs = Fax Ss and SM1 = Fv x S1 Site Class D — Fa = 1.0 ,Fv = 1.517 Period Sa (sec) (g) 0.2 1.413 (SMs, Site Class D) 1.0 0.733 (SM1, Site Class 0) 1 =1 NO PUBLIC ACCESS R =6 MOM. CONN. R =4 BRACED W =D.L.+ 3 L.L. Conterminous 48 States 2005 ASCE 7 Standard Latitude = 47.4536 LOAD PER COLUMN Longitude = — 122.2501 Design Spectral Response Accelerations SDs and SDI L.L. =? x 8x2 =5 3 K SDs = 2/3 x SMs and SDI = 2/3 x SM1 3 2 Cod Site Class D — Fa = 1.0 ,Fv = 1.517 Period Sa (sec) (g) 0.2 0.942 (SDs, Site Class D) 1.0 0.488 (SD1, Site Class 0) SHEET NO, 2 JOB NO.. RD - 13850 BY...., G. OHANIAN DATE. 12 - 10 - 08 SUBJECT COLUMN ANALYSIS M x- 3 - t =.09` P= 8x2 =8 K 1 00% LOAD 2 COL W .2..- 8.0 8.2 COMBINED STRESS RATIO + — M ax + 26 = .68 <1.33 ax — BASE PLATE ANCH. TENSION = 7— (8.2x3 ") 6" ANCHOR SHEAR = • 29 2 3 K (2)-1/2"0 ANCHORS HILTI KWIK BOLT —TZ ESR -1917, SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 7/16 "0 RIVET A =.1 Fy = 79 KSI Va = .1x79x.4 = 3 K Ma =3Kx4 "x1.33 = 16" K 3 PIN CONN. CONN. RACK DENIGIN & ENdINEERINGt CO. 412 WE BROADWAY, !MITE #204 LENDALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 Fy =55 KSI A =.78 S x =.80 r =1.2 r =1.1 =0 KI x =2 .27 =34 r K1 - � - 47 Y • Max =S .F =26 'K 6.9 'K Fe= ( K j = 128 T Fn =Fy(1— 4F ) =49 P =F xA= 38 K P _ P n —20 K P, 1.92 = 82 K 7 " SHEET NO. 3 JOB NO. RD - 13850 7 3/4 "x5 "x3/8" BASE PLATE , By . G. OHANIAN DATE. 12 -10 -08 SUBJECT OVERTURNING = .89 "x.5x1.15 =196 M OT MR = 5.3 K x44" = 233 'K NO UPLIFT LOAD TO DIAGONAL P = .89 Kx2x 4 = .57 K F =55 Ks1 A =.31 r =.48 Q =.74 L= 58" CHECK WELDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 K CHECK SLAB 8200 1000 — 8 . 2 °' l0 =34" F = 10.3 KS1 P ° = 3.3 8.2x144=1180 °'' M= (12 )2x1000x 2 x12 = 4166 "# s= 12x6 = 72 6 4166 = 58 <1.6 2 =80 72 RAdK DEfiIIC N & ENdINEERINGI do. 412 WE BROADWAY, QUITE #204 =DALE, dA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 TOP LEVEL LOADING (100% LOAD) L.L. =1 x2 K =2 K W . 2LL 2.2 V _ .94x1x2.2 = 36 K TRANS. 4x1.4 • BOTH SIDES TYP. fl X 4 t =.07" 8200 6 SHEET NO. 4 JOB NO.. RD -13850 MOT = .36Kx192 "= 69 'K MR= 2.2Kx22 " =48 'K UPLIFT = 69-48 .48 K 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL 06 -03 -2009 MIKE SORENSON 1100 SW 7 ST RENTON WA 98057 RE: Permit No. D08 -518 401 ANDOVER PK E TUKW Dear Permit Holder: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 07/26/2009 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician xc: Permit File No. D08 -518 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 0 Fax: 206 - 431 -3665 DEPs ' TMENTS: Bui sin Divisio Public Works Complete Comments: APPROVALS OR CORRECTIONS: Documentshouting slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D08 -518 DATE: 12 -23 -08 PROJECT NAME: FATIGUE TECHNOLOGY SITE ADDRESS: 401 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response,to Incomplete Letter # Revision # After Permit Issued U Structural ❑ Permit Coordinator DETERMINA N OF COMPLETENESS: (Tues., Thurs.) Permit Center Use Only ; I INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS RO TING: Please Route Structural Review Required U No further Review Required n REVIEWER'S INITIALS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: OA 0" Fire revention Incomplete ❑ Planning Division DUE DATE: 12 -30-08 DATE: DATE: Not Applicable DUE DATE: 01 -27-09 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 TRAVS 81S103354822BCM10/01/2001 KOSTY, CLARK R Can Cancelled 01/01/1980 $12,000.00 10/09/2001 5 TRAVELERS CASUALTY Et SURETY 815103354822BCM 10/01/200010/01 /2001 $6,000.00 01/04/2001 4 UNITED PACIFIC U2160121 10/01/199710/01 /2000 $6,000.00 3 UNITED PACIFIC INS CO U2160121 10/01/199310/01 /1997 $4,000.00 2 FIDELITY & DEPOSIT CO 30132992 04/06/198810/01 /1993 54,000.00 1 GREAT AMERICAN INS CO 9740689 04/06/198104/06 /1988 Name Role Effective Date Expiration Date FRANCK, JAMES J 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Untitled Page General /Specialty Contractor A business registered as a construction contractor with Lftl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County KING NORTH WEST HANDLING SYS INC 4252550500 1100 SW 7TH ST RENTON WA 980552939 Business Type CORPORATION Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 600051641 ACTIVE NORTHWH275JF CONSTRUCTION CONTRACTOR 4/6/1973 10/9/2009 GENERAL UNUSED Business Owner Information Bond Information • • Page 1 of 2 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= NORTHWH275JF 01/05/2009 z � z 0 0 C 0 (0 F N fA CO = :.. a . a cu p i a to 8 13 al g < 5 fit AIM. ' FSOCtEr m y C v Q ► ea 3D 0 c 33 a m m 0 33 • coe L(1 TPS 33 m cn 0 cn z SHEET DESCRIPTION TYPE "K" 65X122 TYPE "J" 65X122 TYPE "J" 65X122 TYPE "J" 65X122 TYPE "K" 65X122 A 1 O'_2" ^ � X `. • t� 3 c c Li ri SCALE AS SHOWN REVISIONS /1 X 0 s w. " ' f v � ! : O to 1:3 ' 0 ' ' < . .a < • Qg E•* 1 TI 0 A 0 W a (a Z C � ! r .81 Er 0 c 8 8 E a -..* o rri o� cf2 as 3 • H1:\ ij A A ap --4 In V 4. ce Z c� a g® r , cr co N PALLET RACK PERMIT 44X5 44X96 44X54 44X96 44X54 44X96 n \: } .. \Z .1.' O\\,\.. \\\ Cdr \< H 0 \\- 414. 7„ed l.i. Z - 70 D = z z H PROJECT TITLE »4x90 mx94 adAL »►x94 ..a.. 3dAJ. »4x94 a,. 3dAJ. ri►xOP ..3., adA.L ft x94 3dU »3x94 a" ad.S 114x94 "3,, adA.L »1x94 ,3, 3dA.L »4x94 a , aaA.L t'1 it Nit 0 1 II • r OCX 0000.r II z r 1 rnirn 1 C)C)000C)00 .° t o L_.1 1 6 N 14' H • a 44x106 44X106 44x106 44X106 44x106 44x166 A05 /1157 FATIGUE Alr TECHNOLOGY INC. :8 H 113x6► ..3.. 3dA.L 113x60 ..3.. adA.L H 143x60 3.. adA.l »1x94 3dAl, PP WOO ..3,.ad.AL »4x94 ri►xw aduJ. ..3" 3d.0 1,1x64 ..3,. adA.L mx94 ,.a, adA.L $1.1x91 a., adA.L »►x90 ..a" UAL a" adA.L ri a,. a4A.L trim ..a" aaA.L ri }x90 a" adA.L ritx9r ..3,. 3dA1 ri►x9r adA3. »4x94 a,. adA.L ?Met "3.. 3dA.L a,. iLU »►x90 a,. adAJ NOT PUBLISHED. ALL RIGHTS RESERVED. THESE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTS THEREBY ARE AND SHALL REMAIN THE PROPERTY OF NWHS. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISCLOSED OR DISTRIBUTED TO OTHERS, SOLD PUBLISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF NORTHWEST HANDLING SYSTEMS. : MOM „n ad mos 6, aaAJ. e °L adAL ..a a� ,.M a dA.1. .$21. 3 d dA A.L , M 3 a aau 0 24x72 24x60 ECECEMEIEE 24x60 24x60 24x60 24x6. 24x60 24x60 1 24x72 1 24x72 1 24x72 I 24x72 24x72 24x72 1 24x721 24x721 24x72 P • .H • • • • 1100 SW 7TH STREET RENTON WA 98055 (425) 255 -0500 1T N0RTHWEST ANCHORAGE PORTLAND SPOKANE EUGENE YAKIMA 0 BOTH SIDES TYP. t =.07" SEC. A -A BRACING DETAIL FRONT VIEW SIDE VIEW 7/16 "0 RIVET ASTM A576 -90B 3 PIN CONNECTION 108" & 54" 11 1( 11 1 Jl JI J( JL 4. 4. 4. 4. • a d� DD cV N 2 00\ 44" 3 : 3 6 6 6 6 N) 3 t =.09" LO (2)-1/2 ANCHOR BOLTS PER BASE PLATE 3 1/4" EMB., (SEE NOTE NO. 4) TYP t =3/8" co A .4 SSS : < A , 4, • . .. • Q O Gmi . ' e ' . E . �. • d d • GENERAL CONFIGURATION NOTES: 1— DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2006 EDITION 2 —STEEL FOR ALL SHAPES FY =55 KSI. ASTM A607 -85 GR.55 (EXCEPT AS NOTED) 3 —NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES) 4 —ALL ANCHORS HILTI KWIK BOLT —TZ (ESR -1917) SPECIAL INSPECTION IS REQUIRED, IN ACCORDANCE WITH SECTION 1704.13 OF THE CBC 2007. THE SPECIAL INSPECTOR SHALL VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, HOLE DIMENSIONS, HOLE CLEANING PROCEDURES, ANCHOR SPACING, EDGE DISTANCES, CONCRETE THICKNESS, ANCHOR EMBEDMENT, AND TIGHTENING TORQUE. 5— CONCRETE SLAB 6" THICK 2500 PSI. SOIL BEARING CAPACITY 1000 PSF 6— STORAGE RACK CAPACITY 2000 #/ LEVEL 7 —RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (SEE NOTE NO. 6) 8— STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF 1/2" IN 10' -0" OF HEIGHT 9 —THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. RECEIVED CITY OF TUKWILA DEC 2 3 2008 PERMIT CENTER EXPIRES 12 -26 -09 A REV. DATE SCALE: NONE DATE: 12 -10 -08 PROJECT: STORAGE RACK DETAILS OLCu I rUfft E COMPLIANCE APP JAN 0 2 2008 aty Of Tukwila N ORISON REVISION RACK DESIGN AND ENGINEERING 412 WEST BROADWAY, SUITE #204, GLENDALE, CA. 91204 FATIGUE TECHNOLOGY, INC. 401 ANDOVER PARK EAST, TUKWILA, WA. 98188 DRAWN BY: JOB NO. RD -13850 SHEET NO. 1 OF 1