HomeMy WebLinkAboutPermit M08-004 - SEATTLE CHOCOLATESSEATTLE CHOCOLATES 1180 ANDOVER PK W M08 -004 Parcel No.: 3523049085 Address: Suite No: 1180 ANDOVER PK W TURIN CitAf Tukwila Tenant: Name: SEATTLE CHOCOLATES Address: 1180 ANDOVER PK W , TUKWILA WA Owner: Name: DANELLIE LLC Address: 4664 95TH AVE NE , YARROW POINT WA Contact Person: Name: ROBERT DAVY Address: 2701 152 AV NE , REDMOND WA Contractor: Name: TRI MECHANICAL INC Address: P.O. BOX 444 , REDMOND WA Contractor License No: TRIMEI *044KB Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us MECHANICAL PERMIT DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT M06 -186. INSTALL HVAC SYSTEM FOR TENANT IMPROVEMENT PROJECT Value of Mechanical: 118,675.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Fees Collected: $1,168.76 International Mechanical Code Edition: 2006 EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 4 0 0 0 0 0 0 0 * *continued on next page ** M08 -004 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425- 391 -6016 Phone: 425 391 -6016 Expiration Date: 05/02/2009 M08 -004 04/04/2008 10/01/2008 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 Printed: 04 -04 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us s,d1L Permit Number: MO8 -004 Issue Date: 04/04/2008 Permit Expires On: 10/01/2008 Date: 4 --u - oS I hereby certify that I have r -ad and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this p- does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p o ance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: Print Name: % This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -004 Printed: 04 -04 -2008 Parcel No.: 3523049085 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1180 ANDOVER PIC W TUKW SEATTLE CHOCOLATES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 4: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS * * continued on next page ** Permit Number: Status: Applied Date: Issue Date: 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. M08 -004 ISSUED 01/04/2008 04/04/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M08 -004 Printed: 04 -04 -2008 I hereby certify that I have this work will be complied The granting of this permi construction or the perfo Signature: Print Name: doc: Cond -10/06 read these conditions and will comply with them as outlined. All provisions of law and ordinances governing with, whether specified herein or not. I • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us does not presume to give authority to violate or cancel the provision of any other work or local laws regulating ance of ork. 7 ied--P-A( M08 -004 Printed: 04 -04 -2008 Name: Contact Person: E -Mail Address: CITY OF TUKWIL'' Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Mailing Address: 277 if f �j P l 'E E -Mail Address: 2 2t 'y/1 1 C 1 C G 1. cp Contact Person: E -Mail Address: Contractor Registration Number: Q:4lpplications\Forms- Applications On Linel3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Mec hanical Permit No. Proiecf No. . (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.:....52.3c -t —j O T Site Address: t F l y, Suite Number: � Floor: Tenant Name: 3t a ,. ( C �j E New Tenant: ^.... Yes El ..No Property Owners Name: p�-vv e-L2 1 L 7 � Mailing Address: f 1 ) A J) t4- Ia . 1 4 /r - Ti) K 14)11 IAA c l S ar City State Zip CONT i RSON - wt► do we cents t when your permit is ready Day Telephone: 1 -41, 3c 1 • (./O I (% kvl nn),) jit a j �S 2 Sta Zip ¥f2SS City Fax Number: CHANICAL CONTRACTOR IN` Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: State l ed by Ar Company Name: Mailing Address: City Day Telephone: Fax Number: State Zip Zip 6• Company Name: 1k- `I��/l-j, - 2 C Din U1?NA, CS (hc..., q Mailing Address: 1 1 4, ) t'f v E 37 r ,J Z-E kir+ /(9/b City State Zip Contact Person: -. f FF ►J 1C I - C Day Telephone: 2 .e ` lY 2 z 4 D E -Mail Address: e 0 ' 0 I .,' / at /. • d Fax Number: O CPZZ- - S 7 L 7 Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Li Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ I `g Co l S • OZ) Scope of Work (please provide detailed information): I k i I (V j ` \LS jn/( rOYL To/IA-AR vv ). 12 vEtii -5t1 f' 1 ( CT Use: Residential: New .... Replacement .... Commercial: New ....b Replacement .... Fuel Type: Electric Indicate type of mechanical work being installed and the quantity below: PLAIT A 'PL CA 'ION NOTES - Applicable Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW AUTHORIZED AGENT: Signature: C:71 Date: Print Name: Mailing Address: Date Application Expires: , g . Date Application Accepted: Gas ....0 Other: frevol 5//0910- 11V fiviif 4' Wes" Q:\ Applications \Forms- Applications On Line \3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh I24 7 _ Day Telephone: 2 / 204 ' 2b 74w /2A City I /kJ/ 4 ) - State Zp Staff Initials: uk Page 2 of 2 Parcel No.: 3523049085 Address: 1180 ANDOVER PK W TUKW Suite No: Applicant: SEATTLE CHOCOLATES Receipt No.: R08 -00025 Initials: WER User ID: 1655 Payee: SEATTLE CHOCOLATES ACCOUNT ITEM LIST: Description MECHANICAL - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 15505 485.50 Account Code Current Pmts 000/322.100 485.50 Total: $485.50 • Permit Number: M08 -004 Status: PENDING Applied Date: 01/04/2008 Issue Date: Payment Amount: $485.50 Payment Date: 01/04/2008 11:12 AM Balance: $0.00 6814 01/04 9710 TOTAL 485.50 doc: Receiot -06 Printed: 01 -04 -2008 Pro§ 9 a ox Type o I ,,, ion: Address: I -80 A i/e, pie. Date Called: 4 Specia Instructions: : Date Wanted:._ zi ' 0 � _ p.m. Requester: Phong No: 2 - 2 4 -27/Y CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. R Z Approved per applicable codes. Corrections required prior to approval. 0 $58. INSPECTION FEE RgQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 COMMENTS: F-r4„/ Ue Inspector: Date: Receipt No.: Date: ACTIVITY NUMBER: M08 -004 DATE: 01 -04 -08 PROJECT NAME: SEATTLE CHOCOLATES SITE ADDRESS: 1180 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: B g ivi i o n u t� n g Ivlsln Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route F,1 REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP s„ Pitk Q Fire Prevention Structural n Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n Response to Incomplete Letter # Revision # After Permit Issued DATE: DATE: Planning Division n Permit Coordinator DUE DATE: 01 -08-08 Not Applicable n No further Review Required n ■_./ DUE DATE: 02-05-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License TRIMEI *044KB Licensee Name TRI MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601709252 Ind. Ins. Account Id #6 Business Type CORPORATION Address 1 1824 BOTH AVE Address 2 City BELLEVUE County KING State WA Zip 98005 Phone 4253916016 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/2/1996 Expiration Date 5/2/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 CBIC LC0466 05/01/2006 Until Cancelled 01/01/1980 $12,000.00 03/09/2006 Business Owner Information Name Role Effective Date Expiration Date HILDERBRAND, KURT E 01/01/1980 JOHNSON, DAVE 01/01/1980 JENSEN, RONALD 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail • 4 110 Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= TRIMEI *044KB 04/04/2008 ♦ DESIGNED BY: JN DRAWN BY: ~ RH DATE: 8/17/06 APPROVED BY: JN SCALE: None FILE NAME: 306252 MO.1 _ PROJECT No: 3- 030252 SHEET TITLE: Mechanical Legend SHEET NUMBER: MO.1 t A B C D SYMBOL SINGLE DOUBLE LINE LINE ct --�I �--©I 45 D ' it '. _, ---� )J_ 2 I t - -- 1 n^ i© iQ aa�air aQlra� c 4 ^ (- - --V. i'-_ -2 • NOTE: NOT ALL REQUIRED CHANGES IN DIRECTION ARE SHOWN ON THE DRAWINGS. M E C HAN I CAL SYMBOLS LEGEND (NOT ALL SYMBOLS ARE USED ON THESE DRAWINGS) DESCRIPTION HVAC DUCT CONNECTION TO SUPPLY DIFFUSER, REFER TO DETAILS DUCT CONNECTION TO RETURN GRILLES, REFER TO DETAILS DUCT CONNECTION TO EXHAUST GRILLES, REFER TO DETAILS SUPPLY AIR (SA) ELEVATION CHANGE (SOLID LINE UP, BROKEN LINE DOWN) RETURN AIR (RA), RELIEF AIR OR EXHAUST (SOLID LINE UP, BROKEN LINE DOWN) DUCT RISE /DROP WITH 9O ELBOWS (RECTANGULAR DUCTS) DUCT RISE /DROP W/ 45' ELBOWS (RECTANGULAR DUCTS) DUCT RISE /DROP W/ 90' ELBOWS (OVAL DUCTS) DUCT RISE /DROP W/ 45' ELBOWS (ROUND OR OVAL DUCTS) DUCT RISE /DROP W/ 90' ELBOWS (ROUND DUCTS) RADIUS ELBOW SQUARE ELBOW WITH TURNING VANES SQUARE /RECTANGULAR BRANCH TAKE --OFF Y4 W OR 6" MIN. RECTANGULAR /ROUND, ROUND /ROUND BRANCH TAKE -OFF RADIUS TEE SQUARE TEE W/ TURNING VANES BULLHEAD TEE TRANSITION - ECCENTRIC (15' MAX. SUPPLY) (30' MAX. RETURN /EXHAUST) TRANSITION - CONCENTRIC 15' MAX. SUPPLY) (30• MAX. RETURN /EXHAUST BOOT TEE TAKE OFF FROM THE BOTTOM OF THE DUCT BOTTOM OF THE DUCT 45 DEG. RADIUS ELBOW BELLMOUTH TAKE OFF WITH VOLUME DAMPER BOOT --TEE TAKE OFF WITH VOLUME DAMPER FLEXIBLE DUCT CONNECTOR VOLUME DAMPER MOTORIZED DAMPER BACKDRAFT DAMPER OPPOSED BLADE DAMPER PARALLEL BLADE DAMPER ACCESS PANEL DUCT LINER FLEXIBLE DUCT t SYMBOL w �w ■ L CFM SIZE AFF AP AVTR AHU AD BDD CC CUH DIFF DG DF D TR EWC EC ELEV EEW ES EAT EWT EXH (E) ESP FTR FCO FD GC GCO GR IJS IE KEC LAV LAT LWT MH MVD MC MA MB MD ML (N) NC NO N.I.C. OA OD RA RG RD SH S SA SG TSP UH UV UR VAV VTR WC WCo DESCRIPTION WORK DEFINITION CONNECTION TO EXISTING DISCONNECTION FROM EXISTING GRILLE, REGISTER AND DIFFUSER CALLOUT INDICATES DETAIL AND SHEET NUMBER WHERE ADDITIONAL INFORMATION ABOUT DETAIL CAN BE FOUND MECHANICAL EQUIPMENT CALLOUT; REFER TO MECHANICAL EQUIPMENT SCHEDULE INDICATES SECTION AND SHEET NUMBER WHERE SECTION CAN BE FOUND FIXTURE CALLOUT DETAIL /FLAG NOTE REVISION SYMBOL REMOVE EXISTING MECHANICAL EQUIPMENT /WORK ABBREVIATIONS ABOVE FINISH FLOOR ACCESS PANEL ACID VENT THROUGH ROOF AIR HANDLING UNIT AREA DRAIN BACK DRAFT DAMPER CONTROL CONTRACTOR CABINET UNIT HEATER DIFFUSER DOOR GRILLE DRINKING FOUNTAIN DUCT THROUGH ROOF ELECTRIC WATER COOLER ELECTRICAL CONTRACTOR ELEVATION EMERGENCY EYEWASH /SHOWER EMERGENCY SHOWER ENTERING AIR TEMPERATURE ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERNAL STATIC PRESSURE FIN TUBE RADIATION FLOOR CLEAN OUT FLOOR DRAIN GENERAL CONTRACTOR GRADE CLEAN OUT GRILLE IN JOIST SPACE INVERT ELEVATION KITCHEN EQUIPMENT CONTRACTOR LAVATORY LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE MANHOLE MANUAL VOLUME DAMPER MECHANICAL CONTRACTOR MIXED AIR MOP BASIN MOTORIZED DAMPER MOTORIZED LOUVER NEW NORMALLY CLOSED NORMALLY OPEN NOT IN CONTRACT OUTSIDE AIR OVERFLOW DRAIN RETURN AIR RETURN GRILLE ROOF DRAIN SHOWER SINK SUPPLY AIR SUPPLY GRILLE TOTAL STATIC PRESSURE UNIT HEATER UNIT VENTILATOR URINAL VARIABLE AIR VOLUME VENT THROUGH ROOF WATER CLOSET WALL CLEAN OUT E E 23' --6" AFF 16' -0" AFF EAST ELEVATION \ PLAN VIEW 20 720" OSA W/ SL 6"/36" FAN COIL UNIT DETAIL NOT TO SCALE 23' -6" AFF 16' -O" AFF RA $ #RA FCU 03 NORTH ELEVATION rI In I Il III II UI LJ I II Ill II I III Li PLAN VIEW 20 730" OSA W/ SL 4') FAN COIL UNIT DETAIL pul NOT TO SCALE WEST ELEVATION BIRD SCREEN ROOF ANGLE CEILING L PREFABRICATED ROOF CURB / ROOF MOTORIZED DAMPER OR BACKDRAFT DAMPER AS REQUIRED DUCT SIZE EQUAL TO THROAT SIZE 3 RELIEF /INTAKE HOOD DETAIL NOT TO SCALE G !ti[n�YiQn� F;s�n r•r; —: I • $eQUI Ch9CQI9fe ] CIF MULTI k&fnrd ioGgeml thag, le,r,S vd l>q9, d a6xrd pP9 Iri.7 : � 7 n. �,sl pxr SYSTEM SCHEMATIC DWC. II UIU V l . { > i P* - scscnn E 2 AREA OF WORK THIS PERMIT (TENANT IMPROVEMENTS -- NEW HVAC) nn~ k•l 5 1' , _ , ,,j � I a y,a f Pt ,. le. . s '. 4 a 5 u, 4 ,. a, F 7,ili•N yy. .+ 7nF :M 4 . . H use (SI P Pt4�'ICiIU -1. �� 051 i !-r-----. ..._ .. r-i gg55 L. re I, - : a.75mm 20 A'W 5 : betwS n 5 vn 4 AkG) c rtd O.75mn (YA A19G). fl1�L SUPPt L Jj PIFPARm 9N 20P6�02 SYSTEM DIAGRAM NOT TO SCALE FILE • S : \\ e 1 - —' —' dally QFrlC& �,.' , ' ratswoK x a h 4 £,.$ I �•..... -'r:�r7taa�:,+ =- �:^'.:i..•'`y�Ls•1:.I... - 'ty;� _ -.-.. , -yam.. o- crc�i'7a: - -- _ 1 -- _ - , N4VYF Pl1F,1 1{t;ST - — . i; PLAN SITE Q NOT TO SCALE f a C,rwr..ri v w s 1:m3, H° - - 519&h 51 Pl review 8p 1oVel i9 subject to errors and tth TTT e � rr ��� f olation of any dopted code or brdCl . = of red :d and i = ..a B + /C L - tk QS:V �,� a ,Ja.n a. S , Iin( r ' VICINITY PLAN: -P144IWN -A U54 u t.. —. - 3 , - ICd WIC, g y•Fbha' 7 NORTH n rnw ru . yap 9 MOS -do`+ REV!SIONS No changes shall be mad of work without prior a Tukwila Building Di NOTE: Revisions will require a n and may include additional pl Penult No. _4 -. _a4-a. . t°' Eu E I � I f �r v wnrx ,. a S I a41h 5t i 1_.• of Tukwa bIN DIVISION SEpARAT PERMIT REQUIR ED Iv ec tan1Ca Iectn lumbing [Gas Piping qty of Tukwila BUf;DlNG siVIS ON C. w.ru S 4 to the scopQ proval of ision w p!an submi#fel n review fees t .9 - JAW 04 2008 - - ERM!T Cr'I . r O N Co I— Q' N ry n 0 0 _ a LL s W c I o a 0 . Co � N a �In Wr � o U W I _J �_ N w W P ` DESIGNED BY: JN S DRAWN BY: RH DATE: 8/17/06 APPROVED BY: JN SCALE: None FILE NAME: 306252 MO.2 PROJECT No: 3- 030252 SHEET TITLE: Mechanical Specifications ~ SHEET NUMBER: M O2 ... .. UE RECORD 1 e DESCRIPTION I N Lf N • 1 2 3 4 5 6 7 A B C D SECTION 15010 - GENERAL REQUIREMENTS PART 1 - GENERAL 1.01 FURNISH ALL MATERIALS, EQUIPMENT, TOOLS, AND LABOR RELATED TO THE INSTALLATION OF THE MECHANICAL WORK AS INDICATED ON THE DRAWING AND SPECIFICATION HEREIN. CONNECT ALL FACILITIES TO BE INSTALLED FOR A COMPLETELY COORDINATED AND INTEGRATED MECHANICAL SYSTEM. IT IS THE INTENT AND PURPOSE OF THESE DRAWINGS AND SPECIFICATIONS THAT UPON COMPLETION OF PROJECT, THE MECHANICAL INSTALLATION, INCLUDING ALL SYSTEMS, SHALL BE COMPLETE AND OPERABLE IN ALL RESPECTS. 1.02 NEW WORK SHALL BE OF THE HIGHEST INDUSTRY STANDARD. THE GOOD APPEARANCE OF THE FINISHED WORK SHALL BE OF EQUAL IMPORTANCE WITH ITS MECHANICAL EFFICIENCY. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ACCEPTABLE INDUSTRY PRACTICES. 1.03 THE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND INDICATE THE GENERAL ARRANGEMENT OF MECHANICAL WORK, BUT DO NOT INDICATE EVERY REQUIRED OFFSET, FITTINGS, OR ACCESSORY. LOCATIONS ARE APPROXIMATE AND SHALL BE SUBJECT TO MINOR MODIFICATIONS. FIELD VERIFY ALL CRITICAL COMPONENTS AND DIMENSIONS. RECORD MODIFICATIONS ON "AS- BUILT "DRAWINGS. 1.04 CERTAIN VERTICAL AND HORIZONTAL OFFSETS ARE SHOWN IN DUCTS AND PIPING TO INDICATE THE GENERAL POSITION RELATIONSHIP OF THE SYSTEMS WITHIN THE SPACE AVAILABLE FOR SYSTEM INSTALLATION. PROVIDE ADDITIONAL OFFSETS AS REQUIRED TO COORDINATE WITH INSTALLATION REQUIREMENTS OF OTHER SYSTEMS. 1.05 ARRANGE AND PAY FOR ALL NECESSARY PERMITS, FEES, INSPECTION SERVICES, TAXES, AND ROYALTIES IN CONNECTION WITH THE MECHANICAL WORK ON THIS PROJECT. 1.06 ALL WORK, MATERIALS, AND EQUIPMENT SHALL COMPLY WITH THE RULES AND REGULATIONS OF ALL CODES AND ORDINANCES OF THE LOCAL, STATE, AND FEDERAL AUTHORITIES. SUCH CODES, WHERE APPLICABLE, SHALL TAKE PRECEDENCE OF THESE PLANS AND SPECIFICATIONS. 1.07 MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2003 EDITIONS OF THE INTERNATIONAL BUILDING CODE, INTERNATIONAL MECHANICAL CODE, UNIFORM PLUMBING CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, , THE NATIONAL ELECTRICAL CODE, 2003 INTERNATIONAL FUEL GAS CODE, AND LOCAL CODES AND ORDINANCES. 1.08 IN THE EVENT OF A CONFLICT OR INCONSISTENCY BETWEEN ITEMS INDICATED ON THE PLANS AND /OR SPECIFICATIONS OR WITH CODE REQUIREMENTS, THE NOTE, SPECIFICATION, OR CODE THAT PRESCRIBES AND ESTABLISHES THE MORE COMPLETE JOB OR THE HIGHER STANDARD SHALL PREVAIL. 1.09 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING CURRENT REQUIREMENTS WITH THE MANUFACTURER OF THE PRODUCTS USED ON THE PROJECT. NOTIFY THE ENGINEER IF ANY DISCREPANCIES ARE FOUND BEFORE ANY WORK TO INSTALL THE PRODUCT IS PERFORMED. 1.10 WHEREVER MORE THAN ONE (1) MANUFACTURER'S PRODUCT IS SPECIFIED, THE FIRST -NAMED PRODUCT IS THE BASIS FOR THE PROJECT DESIGN AND THE USE OF ALTERNATIVE NAMED MANUFACTURER'S PRODUCTS OR SUBSTITUTES MAY REQUIRE MODIFICATIONS IN THE PROJECT DESIGN AND CONSTRUCTION. IF SUCH ALTERNATIVES ARE PROPOSED BY THE CONTRACTOR AND ARE FAVORABLY REVIEWED BY THE RESPONSIBLE DESIGN PROFESSIONAL, THE CONTRACTOR SHALL ASSUME ALL COSTS REQUIRED TO MAKE NECESSARY REVISIONS AND MODIFICATIONS TO THE ORIGINAL PROJECT DESIGN INCLUDING ADDITIONAL COSTS FOR EVALUATIONS OF THE MODIFICATIONS BY THE RESPONSIBLE DESIGN PROFESSIONAL. 1.11 A. SUBMIT THREE (3) COPIES OF SUBMITTAL DATA FOR MECHANICAL MATERIAL AND EQUIPMENT TO THE ENGINEER FOR REVIEW PRIOR TO ORDERING OR FABRICATION OF THE MATERIAL OR EQUIPMENT. B. SUBMITTALS WILL BE REVIEWED BY ENGINEERING ECONOMICS, INC. ONLY FOR THE PURPOSE OF DETERMINING THAT THE MATERIALS, EQUIPMENT AND INSTALLATION METHODS ARE IN ACCORDANCE WITH THE PROJECT DESIGN CONCEPTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SPACE REQUIREMENTS, CONFIGURATIONS, PERFORMANCE, BASES, SUPPORTS, STRUCTURAL MEMBERS AND OPENINGS IN STRUCTURE, AND OTHER APPARATUS THAT MAY BE AFFECTED BY THE MATERIAL,EQUIPMENT OR INSTALLATION. C. NOTE ANY DEVIATIONS FROM SPECIFIED REQUIREMENTS. D. ORGANIZE SUBMITTALS TO INCLUDE AS A MINIMUM THE FOLLOWING: COVER SHEET INDICATING GENERAL CONTENTS BY APPLICABLE SPECIFICATION SECTION NUMBER AND ITEM NAME. E. THE DATA FOR EACH ITEM SUBMITTED SHALL BE THOROUGHLY EDITED FOR THE SPECIFIC EQUIPMENT AND INTENDED APPLICATION AND OPERATION. F. INCLUDE CURRENT PUBLISHED CATALOG AND SPECIFICATION SHEETS PERTAINING TO PROPOSED MATERIAL AND EQUIPMENT. INCLUDE ELECTRICAL CHARACTERISTICS, WIRING AND CONTROL DIAGRAMS. G. IDENTIFY EACH ITEM WITH IDENTIFICATION CODE IDENTICAL TO THOSE USED ON THE DRAWINGS AND IN THE SPECIFICATIONS. 1.12 A. LOCATIONS AND SIZES OF EXISTING UTILITIES ARE SHOWN IN ACCORDANCE WITH THE EXISTING BUILDING RECORD DRAWINGS AND ON -SITE OBSERVATIONS. CHECK AND VERIFY ALL DATA GIVEN, AND VERIFY EXACT LOCATIONS OF ALL UTILITIES PERTAINING TO THE WORK. B. THE CONTRACTOR SHALL VISIT THE EXISTING BUILDING(S) AND GROUNDS AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS. EXISTING RECORD DRAWINGS ARE AVAILABLE IN THE FACILITIES DEPARTMENT FOR CONTRACTOR REVIEW. NO SUBSEQUENT ALLOWANCE ON BEHALF OF THE CONTRACTOR WILL BE MADE FOR OMISSIONS, ERRORS, OR NEGLIGENCE ON THE CONTRACTOR'S PART FOR NOT FAMILIARIZING THEMSELVES WITH EXISTING CONDITIONS. C. VERIFY AT PROJECT SITE EXACT SIZE, LOCATION, AND CLEARANCES OF EXISTING SERVICES AND MECHANICAL AND ELECTRICAL EQUIPMENT. D. THE CONTRACTOR SHALL REMOVE, RELOCATE, REPLACE WITH NEW AND /OR RECONNECT ALL EXISTING SERVICES AS REQUIRED BY NEW CONSTRUCTION. 1.13 CLEARANCES AND ACCESS SHALL BE MAINTAINED ON ALL NEW AND EXISTING EQUIPMENT TO ENSURE PROPER EQUIPMENT MAINTENANCE. 1.14 THE CONTRACTOR SHALL MAKE THEIR OWN PROVISIONS FOR DELIVERY AND SAFE STORAGE OF ALL MATERIALS AND SHALL ASSUME FULL RESPONSIBILITY FOR CONDITIONS AND /OR SAFEKEEPING OF MATERIALS, FURNISHED BY OTHERS UPON ACCEPTANCE OF SAME. 1.15 A. THE CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR SAFETY OF ALL PERSONS ON OR ABOUT THE CONSTRUCTION SITE, IN ACCORDANCE WITH APPLICABLE LAWS AND CODES. GUARD ALL HAZARDS IN ACCORDANCE WITH THE SAFETY PROVISIONS OF THE LATEST MANUAL OF ACCIDENT PREVENTION. B. COORDINATE AND SCHEDULE ALL WORK WITH THE FACILITY INCLUDING CONSTRUCTION ACCESS AND STORAGE. THE CONSTRUCTION SCHEDULE AND HOURS OF WORK SHALL BE APPROVED BY THE FACILITY PRIOR TO THE START OF CONSTRUCTION. C. ALL UTILITIES REQUIRED FOR THE CONTINUOUS OPERATION OF ALL EXISTING FACILITIES MUST BE MAINTAINED IN SERVICE AT ALL TIMES EXCEPT AS REQUIRED FOR NEW SYSTEMS CONNECTION. COORDINATE SHUTDOWN WITH RESPONSIBLE FACILITY PERSONNEL. D. ALL SERVICE SHUTDOWNS AND START -UPS SHALL BE SCHEDULED A MINIMUM OF 72 HOURS IN ADVANCE AND SUPERVISED BY THE FACILITY ENGINEERING STAFF. 1.16 ALL REMOVED ITEMS DEEMED TO HAVE VALUE BY THE OWNER SHALL BE DELIVERED TO A PLACE OF STORAGE AT THE SITE AS DIRECTED. ALL OTHER ITEMS MUST BE DISPOSED OF OFF -SITE IN A LEGAL MANNER. 1.17 WHERE EXISTING CONSTRUCTION IS CUT, DAMAGED, OR REMODELED, PATCH WITH MATERIALS TO MATCH IN KIND, QUALITY, AND PERFORMANCE. 1.18 ALL PIPE AND DUCT SIZES ARE IN INCHES. 1.19 CLEAN ALL NEW SURFACES AND NEW EQUIPMENT AFTER THE COMPLETION OF THE INSTALLATION. 1.20 WARRANTY: THE CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP, MATERIALS, AND EQUIPMENT FURNISHED AND INSTALLED HEREUNDER FOR A PERIOD OF 365 CALENDAR DAYS FROM THE DATE OF FINAL ACCEPTANCE OF WORK BY OWNER, AGAINST ALL DEFECTS AND FAULTY WORKMANSHIP. PARTIAL OCCUPANCY OF PROJECT SITE BY OWNER SHALL NOT BE CONSTRUED AS FINAL ACCEPTANCE OF WORK. CONTRACTOR SHALL REPAIR AND /OR REPLACE ALL DEFECTIVE AND /OR FAULTY WORKMANSHIP, MATERIALS, AND /OR EQUIPMENT, AND SHALL REPAIR AND /OR REPLACE ALL OTHER WORK DAMAGED AS A RESULT OF SUCH DEFECTIVE AND /OR FAULTY WORKMANSHIP, MATERIALS, AND /OR EQUIPMENT WITHOUT CHARGE TO OWNER DURING WARRANTY PERIOD. 1.21 CONTRACTORS SHALL MAINTAIN RECORDED "AS- BUILT" INFORMATION ON ALL EXISTING SERVICES /EQUIPMENT RELATED TO THE PROJECT UNCOVERED DURING CONSTRUCTION AND ALL NEW WORK INSTALLED DURING CONSTRUCTION AND IT SHALL BE CLEARLY MARKED IN COLORED PENCIL ON A PRINT OF PRODUCT DRAWINGS. RECORDED INFORMATION SHALL INCLUDE ROUTING, ACTUAL LOCATIONS, POINTS OF CONNECTIONS, ELEVATIONS, OR OTHER INFORMATION THAT DEVIATES FROM THE ORIGINAL DESIGN DRAWINGS. THE CONTRACTOR SHALL TURN RECORDED "AS- BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. 1.22 PROVIDE PERMANENT, COMMERCIAL QUALITY PRE - PRINTED IDENTIFICATION ON ALL NEW EQUIPMENT, TERMINAL UNITS, VALVES, DUCTWORK, AND PIPING. E SPECIFICATIONS SECTION 15060 - MECHANICAL SUPPORTS PART 1 - GENERAL 1.01 DO NOT SUPPORT PIPING OR VALVES FROM PIECES OF EQUIPMENT. 1.02 SECURELY FASTEN ALL PIPING AND DUCTWORK WITHIN STRUCTURES TO THE BUILDING CONSTRUCTION BY MEANS OF HANGERS, SUPPORTS, GUIDE ANCHORS, AND SWAY BRACE SEISMIC RESTRAINTS TO MAINTAIN ALIGNMENT, TO PREVENT SAGGING, AND TO PREVENT NOISE AND EXCESSIVE STRAIN DUE TO MOVEMENT UNDER OPERATING CONDITIONS. 1.03 PIPE SUPPORTS SHALL BE DESIGN TO INCLUDE THE WEIGHT OF THE PIPE AND THE WEIGHT OF THE CONTENTS OF THE PIPE. 1.04 ALL MECHANICAL EQUIPMENT SUPPORTS SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER AND SHALL COMPLY WITH THE INTERNATIONAL BUILDING CODE SEISMIC REQUIREMENTS. 1.05 PROVIDE CALCULATIONS AND DETAILS FOR THE SUPPORT AND BRACING OF ALL PIPES, DUCTS, AND CONDUITS, OR PROVIDE SUPPORT AND BRACING PER OSHPD ANCHORAGE PRE - APPROVAL NO. R -0010, THE SMACNA "GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS" OR OSHPD ANCHORAGE PRE-APPROVAL NO. 0003 "THE SUPERSTRUT SEISMIC RESTRAINT SYSTEM FOR PIPES AND CONDUIT ". SECTION 15080 - MECHANICAL INSULATION PART 1 - GENERAL 1.01 INSULATE DUCT AND BUILT UP PLENUM PER THE LATEST EDITION OF WASHINGTON STATE ENERGY CODE, AND THE MECHANICAL MATERIALS SCHEDULE. PART 2 -- PRODUCTS 2.01 ALL PIPING AND DUCTWORK INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. PART 3 -- EXECUTION 3.01 PROVIDE CONTINUOUS INSULATION AROUND ALL PIPE FITTINGS AND ACCESSORIES. PROVIDE UNBROKEN VAPOR SEAL ON ALL COLD SURFACES. PROVIDE ONE -PIECE PVC PLASTIC JACKETING ON FITTINGS. ALL HANDLES, PLUGS AND OTHER MAINTENANCE ITEMS SHALL BE ACCESSIBLE WITHOUT DAMAGING INSULATION. SECTION 15100, 15400 PIPING / PLUMBING PART 1 - GENERAL 1.01 PIPE INSTALLATION SHALL COMPLY WITH THE MECHANICAL CONTRACTING FOUNDATION INC'S "GUIDELINES FOR QUALITY PIPING INSTALLATION ", LATEST EDITION, EXCEPT A SPECIFICALLY NOTED, AND THE 2003 UNIFORM PLUMBING CODE. 1.02 INSTALL ALL PIPING TO BEST SUIT FIELD CONDITIONS AND COORDINATE WITH THE INSTALLATION WORK OF OTHER TRADES. THE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION OF PIPING. PART 2 -- PRODUCTS 2.01 PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. PART 3 - EXECUTION 3.01 PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 3.02 VALVES, SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. 3.03 THE PLUMBING CONTRACTOR SHALL PROVIDE AND LOCATE ALL REQUIRED FLOOR, WALL SLEEVES. 3.04 PROVIDE VALVES AND OTHER PIPING SPECIALTIES SAME SIZE AS LINE SIZE SHOWN UNLESS OTHERWISE NOTED. SECTION 15910 - CONTROLS PART 1 - GENERAL 1.01 EQUIPMENT TO BE FURNISHED WITH STAND ALONE FACTORY CONTROLS TO PROVIDE COMPLETE TEMPERATURE AND OPERATIONAL CONTROL OF THE UNITS. SEE MECHANICAL SCHEDULE FOR SELECTED EQUIPMENT OPTIONS. SECTION 15950 - AIR / HYDRONIC BALANCING PART 1 - GENERAL 1.01 BALANCING OF THE HVAC SYSTEM WILL BE PERFORMED BY A NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB) CERTIFIED BALANCING CONTRACTOR IN ACCORDANCE WITH ASHRAE SYSTEMS HANDBOOK, CHAPTER ON TESTING ADJUSTING, AND BALANCING, AND NEBB GUIDELINES. 1.02 CONTRACTOR SHALL WORK WITH BALANCER TO CORRECT DEFICIENCIES IN WORK. 1.03 BALANCING CONTRACTOR TO PROVIDE SHEAVES, BELTS AND REBALANCING AS NEEDED TO ACHIEVE THE NECESSARY SYSTEM PERFORMANCE. WASHINGTON STATE ENERGY CODE 1416.4 SYSTEMS COMMISSIONING 1416.4.1 SIMPLE SYSTEMS: FOR SIMPLE SYSTEMS, AS DEFINED IN SECTION 1421, AND FOR WAREHOUSES AND SEMI-HEATED SPACES, HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS PARAGRAPH. 1416.4.2.1 DOCUMENTATION: DRAWING NOTES SHALL REQUIRE COMMISSIONING IN ACCORDANCE WITH THIS SECTION. DRAWING NOTES MAY REFER TO SPECIFICATIONS FOR FURTHER COMMISSIONING REQUIREMENTS. PLANS AND SPECIFICATIONS SHALL REQUIRE TESTS MANDATED BY THIS SECTION BE PERFORMED AND THE RESULTS RECORDED. PLANS AND SPECIFICATIONS SHALL REQUIRE PREPARATION OF PRELIMINARY AND FINAL REPORTS OF TEST PROCEDURES AND RESULTS AS DESCRIBED IN SECTION 1416.4.2.2. PLANS AND SPECIFICATIONS SHALL IDENTIFY THE FOLLOWING FOR EACH TEST: 1. EQUIPMENT AND SYSTEMS TO BE TESTED, INCLUDING THE EXTENT OF SAMPLING TESTS, 2. FUNCTIONS TO BE TESTED (FOR EXAMPLE CALIBRATION, ECONOMIZER CONTROL, ETC.), 3. CONDITIONS UNDER WHICH THE TEST SHALL BE PERFORMED (FOR EXAMPLE WINTER DESIGN CONDITIONS, FULL OUTSIDE AIR, ETC.), 4. MEASURABLE CRITERIA FOR ACCEPTABLE PERFORMANCE. 1416.4.2.2 COMMISSIONING REPORTS 1416.4.2.2.1 PRELIMINARY COMMISSIONING REPORT: A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED. THE PRELIMINARY REPORT SHALL IDENTIFY: 1. DEFICIENCIES FOUND DURING TESTING REQUIRED BY THIS SECTION WHICH HAVE NOT BEEN CORRECTED AT THE TIME OF REPORT PREPARATION AND THE ANTICIPATED DATE OF CORRECTION. 2. DEFERRED TESTS WHICH CANNOT BE PERFORMED AT THE TIME OF REPORT PREPARATION DUE TO CLIMATIC CONDITIONS 3. CLIMATIC CONDITIONS REQUIRED FOR PERFORMANCE OF THE DEFERRED TESTS, AND THE ANTICIPATED DATE OF EACH DEFERRED TEST. 1416.4.2.2.2 FINAL COMMISSIONING REPORT: A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. 1416.4.2.3 ACCEPTANCE: BUILDINGS OR PORTIONS THEREOF, REQUIRED BY THIS CODE TO COMPLY WITH THIS SECTION, SHALL NOT BE ISSUED A FINAL CERTIFICATE OF OCCUPANCY UNTIL SUCH TIME THAT THE BUILDING OFFICIAL DETERMINES THAT THE PRELIMINARY COMMISSIONING REPORT REQUIRED BY THIS SECTION HAS BEEN COMPLETED. REVIEWED FOR CODE COMPLIANCE APPROVED APR - 3 2008 Clay Of Tukv4tla BUILDL G DM . I S rnriv D JAN iJ4 PL. 104 l C A NTEF 0 z z 0 F- z 0 0 Q Q F- Q Y z z z o r-- CO CO ro CT) WAREHOUSE-PACKAG1NG AREA SEATTLE CHOCOLATES MATERIALS SCHEDULE ITEM MATERIAL DESCRIPTION JOINING METHOD REFERENCE STANDARDS INSULATION THICKNESS NOTES REFRIGERANT HOT GAS PIPE TYPE L ARC REFRIGERANT GRADE BRAZED aw_w MIN. 0 ' A ' CFM 1" ELASTOMERIC FOAM ELECTRICAL REFRIGERANT SUCTION PIPE TYPE L ARC REFRIGERANT GRADE BRAZED LAT ( .F 1" ELASTOMERIC FOAM NOTES CONDENSATE PIPE GREENHECK - FABRA HOOD r . . l , 3 - FC -01 SUPPLY AIR DUCTWORK RECTANGULAR GALVANIZED STEEL, LOCK FORMING QUALITY WITH A ZINC COATING OF 1.25 OUNCES PER SQUARE FOOT ON EACH SIDE PER APPLICABLE SMACNA DUCT MANUAL. ALL JOINTS TO BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT (NO DUCT TAPE) SMACNA - GAUGE PER APPLICABLE SMACNA DUCT MANUAL, USE +1" PRESSURE CLASS DUCT SOUNDLINING (WHERE ON THE ON FIBERGLASS DUCT LINING COATED VELOCITIES UPITO 4 08 0 0 ( FPM 3 ASTM -C1071 1" K VALUE= .27 © 75' F DENSITY= 3 LBS /CU FT r- AN - COIL.UNIT�SC / HEDULE CODE MANUFACTURER AND MODEL TYPE CODE MANUFACTURER MODEL OVERALL DIMENSIONS HxWxL MIXING BOX STYLE MB -4) FY CFM aw_w MIN. 0 ' A ' CFM ESP (IN. ELECTRICAL TOTAL COOLING BTU /HR SENS COOLING BTH/ EAT (,F) LAT ( .F EQUIPMENT WEIGHT LBS NOTES IH -02 GREENHECK - FABRA HOOD VOLTS ® PH FLA FC -01 MITSUBISHI PEFY - P72NMHU -E 18.53x49.22x44.13 RFOT 1,950 200 0.3 208 3 4.94 64,170 43,980 70 50 221 1, 2, 3, 4, 5 FC-02 MITSUBISHI PEFY- P54NMHU -E 14.97x47.25x35.43 RTOF 1,400 140 0.3 208 1 3.78 48,130 33,430 70 48 155 1, 2, 3, 4, 5 FC -03 MITSUBISHI PEFY - P54NMHU -E 14.97x47.25x35.43 RTOF 1,400 140 0.3 208 1 3.78 48,130 33,430 70 48 155 1, 2, 3, 4, 5 FC -04 MITSUBISHI PEFY- P72NMHU -E 18.53x49.22x44.13 RFOT 1,950 200 0.3 208 3 4.94 64,170 43,980 70 50 221 1. 2, 3, 4, 5 RELIEF /INTAKE HOOD SCHEDULE CODE MANUFACTURER AND MODEL TYPE CFM TSP THROAT IN. x IN. HOOD SIZE IN. x IN. R WEIGHT ( NOTES IH-01 GREENHECK - FABRA HOOD INTAKE HOOD 1,950 .07 20 "/20" 28 "/28" 52 2 IH -02 GREENHECK - FABRA HOOD INTAKE HOOD 2,800 .07 20 "/30" 28 "/38" 65 2 IH -03 GREENHECK - FABRA HOOD INTAKE HOOD 1,950 .07 20720" 28 "/28" 52 2 RH -01 GREENHECK - FABRA HOOD RELIEF HOOD 6,700 .07 20 "/84" 28 "/92" 150 1, 2 o GRILLE /REGISTER/DIFFUSER SCHEDULE CODE MANUFACTURER AND MODEL SERVICE FACE TYPE MOUNTING TYPE DAMPER MATERIAL NOTES A TITUS MODEL 300 RS FC -02 & FC -03 2" PLUS NECK SIZE DUCT FLANGE FIELD STEEL 2 B TITUS MODEL 300 RS FC -01 & FC -04 2" PLUS NECK SIZE 61 FIELD STEEL 2 AIR COOLED CONDENSING UNIT SCHEDULE _ CODE MANUFACTURER - MITSUBISHI MODEL NUMBER: SERVES INDOOR FAN COIL UNITS NOMINAL COOLING CAP MBH BTH /H ACTUAL COOLING MBH ELECTRICAL WEIGHT (LBS) NOISE LEVEL DBA EER NOTES MCA CU -01 PURY- P144TGMU FC--01 & FC-02 144.0 112.4 208/3 43.8 672 61 10.1 INSTALL ON GRADE CU -02 PURY- P144TGMU FC -03 & FC-04 144.0 112.4 208/3 43.8 672 61 10.1 INSTALL ON GRADE DESIGNED BY: JN DRAWN BY: RH DATE: 8/1 7/06 APPROVED BY: JN SCALE: As Noted FILE NAME: 306252 M1.1 PROJECT No: 3- 030252 SHEET TITLE: Partial Mechanical Floor 1 SHEET NUMBER: M111 N • 1 5 6 7 A B 650 CFM 18710" SPECIFIC SCHEDULE NOTES: 1. AMBIENT TEMPERATURE IS 95 DEG. F FOR SUMMER. 2. EER RATING CALCULATED FOR SYSTEM BY MANUFACTURER. 3. REFRIGERANT R410A, 4. PROVIDE REQUIRED CLEARANCES AROUND EQUIPMENT PER MANUFACTURER. WAREHOUSE - PACKAGING 20720" UP TO IH-01 GENERAL SCHEDULE NOTES: 1. ALL MATERIALS REQUIRED FOR THIS PROJECT MAY NOT BE LISTED IN SCHEDULE. 2. REFER TO MECHANICAL SPECIFICATIONS AND APPLICABLE STANDARDS FOR FURTHER INFORMATION. C GENERAL SCHEDULE NOTES: 1. MAX NOISE CRITERIA NC SHALL BE NC = 30 UNLESS NOTED OTHERWISE. 2. SEE DRAWINGS FOR CFM AND NECK SIZE. (DIFFUSER INLET TO BE SAME SIZE AS FLEX DUCT) 3. PROVIDE BORDER TYPE TO MATCH CEILING. 4. PROVIDE 24x24 OR 24x12 PANEL FOR LAY -IN CEILING APPLICATION. 0 4 8 16 32 48 FT. 1/16" = 1 460 CFM ion/ion 20 "/20" UP TO IH -03 20 "/30" UP TO IH -02 2O "/84" UP TO RH -01 LEADER POINTS TO G -R -D CODE NECK SIZE NEW WALL 460 CFM ion /10" 1 PARTIAL WAREHOUSE PLAN G � FC 04 NORTH D 650 CFM 18 "/10" :7 (SHOWN ON DRAWING) USE WHEN MORE THAN ONE IDENTICAL G -R -D IS USED IN THE SAME AREA. E 7 -- NEW WALL AT MEZZANINE (Ei F 0 4 8 16 SPECIFIC SCHEDULE NOTES: 1. CAPACITY LISTED IS BASED ON DESIGN CONDITIONS. 70' F EAT DB /59' F WS COOLING. 2. FACTORY ADDED ECONOMIZER BOX. (RFOT= RETURN AIR FRONT, OUTSIDE AIR TOP. RTOF= RETURN AIR TOP, OUTSIDE AIR FRONT. 3. SEE AIR COOLED CONDENSING UNIT SCHEDULE FOR SYSTEM EER. 4. MIXING BOXES COMPLETE WITH 1" FILTER FRAME AND FILTER. 5. MINIMUM OSA BASED ON 12,000 SF WAREHOUSE FLOOR AREA x 0.05 CFM /SF PER WASHINGTON STATE VENTILATION CODE. 6, R410A REFRIGERANT. SPECIFIC SCHEDULE NOTES: 1. PROVIDE BACKDRAFT DAMPER. 2. PROVIDE CURB PER DETAIL 3 SHEET M0.1. 3. PROVIDE REQUIRED CLEARANCES AROUND EQUIPMENT PER MANUFACTURER. G 1 /16 " = 1 - 0 " ROOF 2 PARTIAL ROOF PLAN �= 32 48 FT. NORTH SPECIFIC NOTES THIS SHEET: PROVIDE CONDENSATE PIPING CONNECTION, 1 - %2" CONNECTION FROM DRAIN PAN (1 -Y4" NOMINAL PIPE) AND TRAP (PER MANUFACTURER). CONNECT TO EXTERNAL CONDENSATE PUMP AND ROUTE CONDENSATE DISCHARGE TO Os; n F 6 . IMC 307.2.1 Condensate disposal. Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Condensate shall not discharge into a street, alley or other areas so as to cause a nuisance_ g� p p, a C' APPROVED - 3 20 �� Tu�i ppR 08 City VI 10% JAN 04 2006 co a: aD rn