HomeMy WebLinkAboutPermit M08-008 - WESTFIELD SOUTHCENTER MALL - CLAIRE'SCLAIRE'S
2836 SOUTHCENTER MALL
M08 -008
Parcel No.:
Address:
Suite No:
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
DESCRIPTION OF WORK:
MECHANICAL FOR NEW TI
City. If Tukwila
Value of Mechanical: $11,000.00
Type of Fire Protection: SPRINKLERS
doc: IMC -10/06
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
6364200010
2836 SOUTHCENTER MALL TUKW
CLAIRE'S
2836 SOUTHCENTER MALL , TUKWILA WA
WEA SOUTHCENTER LLC
11601 WILSHIRE BLVD , LOS ANGELES CA
PAUL LANDA
2932 NORTHWESTERN AV , RACINE WI
AIRE PRO INC
2921 MERIDIAN AV E , EDGEWOOD WA
Contractor License No: AIREPI *000DA
Furnace: <100K BTU
>100K BTU
Floor Furnace
Suspended/Wall/Floor Mounted Heater
Appliance Vent
Repair or Addition to Heat/Refrig /Cooling System....
Air Handling Unit <10,000 CFM
>10,000 CFM
Evaporator Cooler
Ventilation Fan connected to single duct
Ventilation System
Hood and Duct
Incinerator: Domestic
Commercial/Industrial
MECHANICAL PERMIT
EQUIPMENT TYPE AND QUANTITY
0
0
0
0
0
1
0
0
0
0
0
0
0
0
* *continued on next page **
M08 -008
•
Permit Number:
Issue Date:
Permit Expires On:
Expiration Date: 03/01/2010
M08 -008
06/26/2008
12/23/2008
Phone:
Phone: 262 633 -9900 X 1257
Phone: 253 848 -2626
Fees Collected: $281.10
International Mechanical Code Edition: 2006
Boiler Compressor:
0 -3 HP /100,000 BTU 0
3 -15 HP /500,000 BTU 0
15 -30 HP /1,000,000 BTU.. 0
30 -50 HP /1,750,000 BTU.. 0
50+ HP /1,750,000 BTU 0
Fire Damper 0
Diffuser 0
Thermostat 0
Wood/Gas Stove 0
Water Heater 0
Emergency Generator 0
Other Mechanical Equipment 2
Printed: 06 -26 -2008
Permit Center Authorized Signature:
Signature:
Print Name:
doc: IMC -10/06
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
II hereby certify that I have . d seed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will • - .'' plied t whether specified herein or not.
The granting of this pe '� . es not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the pe ce of work. I am authorized to sign and obtain this mechanical permit.
S ::' ( elec4 4 e. "
•
Permit Number: M08 -008
Issue Date: 06/26/2008
Permit Expires On: 12/23/2008
Date: 61 (Nt'
Date:
6-zc, -ccei
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
M08 -008 Printed: 06 -26 -2008
•
City of Tukwila
Parcel No.: 6364200010
Address: 2836 SOUTHCENTER MALL TUKW
Suite No:
Tenant: CLAIRE'S
1: ** *BUILDING DEPARTMENT CONDITIONS * **
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
PERMIT CONDITIONS
Permit Number: M08 - 008
Status: ISSUED
Applied Date: 01/08/2008
Issue Date: 06/26/2008
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Manufacturers installation instructions shall be available on the job site at the time of inspection.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
9: ** *FIRE DEPARTMENT CONDITIONS * **
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned
in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051)
12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be
equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the
air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors
shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the
manufacturer's installation instructions. (IMC 606.1, 606.2.1)
13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051)
14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051)
15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051)
doc: Cond -10/06
M08 -008 Printed: 06-26 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
•
16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this
project.
18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page **
doc: Cond -10/06 M08 - 008 Printed: 06 -26 -2008
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing
this work will be complied , �a whether specified herein or not.
The granting of this pe s not presume to give authority to violate or cancel the provision of any other work or local laws regulating
construction or the perf •�;y , ce of work.
Signature: Date: 6- ZOO `�'v
Print Name: XmtT ••�`,_,-
doc: Cond -10/06 M08 -008 Printed: 06-26 -2008
SITE LOCATION
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://winv.ci.tultivila.lvaus
Site 2 32 Sp 26k1tm. MALL)
Tenpnt Nnme., gM
Pronerty Owner 7.41tne• ittitirrad) C 7.0
oFfb.P.Ik
Mailing Address:
i 101 WI L5i71
Name: PAUL- L-AiJDA.
Mailing Address: 32._ i\ei4ttitkeilevri
E-Mail Address: pa 610Sti
Cornr:-Iny Mime: — 1 5
Mailing Address:
Contact Person:
E-1`,1.111
Conti.:4(17-T Pgi5trntion 1■Jlirrthor
Contact Person:74
Company NarneW P ME ALA ZWIC
Mailing Address: n TT itv • 1\15 M• --1 4.) AV
Contact Person: AN £'A)
Arirlrnss:
(1:1ApplicationsTornm A61366666=06 Line\.3 1006 Permil Application.cloc
Revir.ed: 9-2006
lilt
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
1 01
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
A will not hp qt-PPTtpd thrnlicrh the or by fqy
e
King Co Aqceqor's Tax No 000/0
S N!
Nrw T(!nlnt! yec 0..No
aLVD LPG AN6i3 got2c
City
- 001
Z:;.
CONTACT PERSON — who do we contact when your permit is ready to be issued
.n?3 To/Thori2/02 -627341tr - ea (7
Fa' Nmbr:
Peathrw, W I ___J
city SIate
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Day Telephone:
.FA
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: MD: Ilekt
Mailing Address: it, 9-2,5 N SCOTTS ..20 DALE" AZ Sf525#
City St:ie zip
Day Telephone: W - qqt3 -4120z,
E-Mail Address:JOn in hen PACtl Fax Numhnr: 9 10
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
IH ft, -0 1
Cy Zp
Day Telephone: 6,0 2 I- 41
Fr!): Numhr.r:
Page 1 nf 6
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Boiler /Compressor:
Qty
Furnace <100K BTU
Air Handling Unit >10,000
CFM
Fire Damper
0 -3 HP /100,000 BTU
Fu_rnace>100K BTU
Floor Furnace
_Eve orator Cooler____ __
•
Ventilation Fan Connected
to Single Duct
_ __
Diffuser _ ____
Thermostat
___ __
3-15 HP/500,000 BTU
15 -30 HP/1,000,000 BTU
—
Suspended/Wall/Floor
Mounted Heater
Ventilation System
Wood/Gas Stove
30-50 1 1P/1,750,000 BTU
Appliance Vent
Hood and Duct
Emergency
Generator
50+ HP /1150,000 BTU
Repair or Addition to
Heat!Refrig/Cooling
System
O
Incinerator - Domestic
Other Mechanical
Equipment
A
y-. ` �,� u f-
C-�
I
Air Handling Unit
<10,000 CFM
Incinerator -- Comm/Ind
MECHANICAL PERMIT INFORMATION — 206-431-3670
AA ECHANj1C I, CONTRACTOR CiYOR uN r.` 97mA Icri
('.mmrani filarn'
Mailing Address:
Contact Person: Day Telephone:
E Add;-.: :.
('einlrae•.tiir !2e?uititratinrf Niirnnber:
V110u60n Or Mr't'h ?viral wt (rernfriolor's hitt price- ): $ 1 )1;0
Scope of Work (piF;reP provi -1e tl(taitCrl jnf rrn lfinn� _
Norq WA/ i N Y1 gkftAtisT Er% 1 ' z
Use. Residential: New .... ❑ Replacement .... ❑
Commercial: New ....RI Replacement ....
Fuel Type: Electric
Gas ....n Other: -
1n(lir4ite type of merhRninhl work tieing in'!atfed and Ihe. quantity bPlnw:
1 2: \ApplicationsWorms- Applictticns On LireO•2006 - Permit Applicatien.doc
Revised: 9-2006
lrI
FATi Ilat.e
Page4of6
Date Application Accepted:
Date Application Expires:
Staff Initials /
1
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of constntction amount should be entered by the applicant. This figure will he reviewed and is subject
to possible.. revision by the Permit Ccntcr to comply with current fee schedules.
N;gpiratinn of Nan 1?Pviaw — Applications for .which no permit is issued within 181) days fnllowing the date of apptiration chalI expire by limitation.
Rttilding_and Mechanical Permit
'1 b' Building Official may grant on e o m or e cgtr•ncinnc of timr for additional +rjnrlc not (\(•C' (ling Q(1 (IP3, (•Hrh ' ! h(' (•vtrncinn Shall be
requested in writing and justifiable cause demonstrated. Section 115 3,9. international liuilding ('ode (rnrrent rditinn).
Signature:
Plumbing Permit
The Bnilrling Official may grant one eYlensi■n of timr for an additional period not eyeeeding 18(1 days The e\:tension shall be requested
in writing and justiciable sties riemonstrated. Section 103.4.3 Uniform Plumbing Code (ryrrent edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TINS APPLICATION AND KNOW TIIE SAME TO BE TRUE UNDER
PENAI;1'Y OF PERJURY BY TI II; LAWS OF '1111i STATE OF WASIIING'1'ON, ANI)1 AM At J'J7IORIZE!)' APPLY FORT/ HS PllRM!T.
BUILDING a YNNLa R AQI OK1LE!D AGENT:
Print Name: cb y 0
Mailing Address: 3 '13' 23roi 1 5
Day Telephone,:
&eisre4/1 t% 4i
City
Date: 1 7/bI5
wt
rt::tc
Q:1Applicctio s\Forms Appiim:iM Linet3 "_',,,,,, icm:it App!ictio n.doc
Revised: 9-7006
Lt.
Page 6 of 6
Parcel No.: 6364200010 Permit Number: M08 -008
Address: 2836 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 01/08/2008
Applicant: CLAIRE'S Issue Date:
Receipt No.: R08 -02319
Initials: JEM
User ID: 1165
Payee: AIRE PRO INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 16053 230.88
ACCOUNT ITEM LIST:
Description
MECHANICAL - NONRES
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Account Code Current Pmts
000/322.100 230.88
Total: $230.88
Payment Amount: $230.88
Payment Date: 06/26/2008 03:23 PM
Balance: $0.00
4164 06/26 9711 TOTAL 230.88
doc: Receiot -06 Printed: 06 -26 -2008
Tlnn• P Y'Q 'TC11R
RECEIPT NO: R08 -00053
Payee: STATE PERMITS INC
SET TRANSACTIONS:
Set Member Amount
ACCOUNT ITEM LIST:
Description
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.ci.tukwila.wa.us
Initials: JEM Payment Date: 01/08/2008
User ID: 1165 Total Payment: 932.22
SET ID: S000000936 SET NAME: Tmp set/Initialized Activities
D08 -012 800.80
EL08 -024 49.20
M08 -008 50.22
PG08 -007 32.00
TOTAL: 932.22
TRANSACTION LIST:
Type Method Description Amount
Payment Check 140719 932.22
TOTAL: 932.22
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
SET RECEIPT
Account Code Current Pmts
000.345.832.00.0 49.20
000/345.830 883.02
TOTAL: 932.22
6970 01/08 9710 TOTAL 932.22
Project,
Type of Inspection:
Address: •
a-03 rh A l (
Date Called:'►
Special Instr
..
•
Date Wanted: e.nim7.
`�- 21 --q-°
Requester:
Phon No: [f�
toS - 6 + 36 `
H
INSPECTION RECORD
Retain a copy with permit
1 C 'T
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 =3670
OMMENTS:
Ff O ea c_a /e -e
Date: 74,4
Approved per applicable codes. ❑ Corrections required prior to approval.
ri $60 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be
pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
COMMENTS:
Type of Inspection:
—
\I . — i
LL.
44If-c's
no.iw-2--Pam
trigs
w1.; A.-
L,# —2r
t
Requester:
Phone No:
e 's •.m
• 4
Project: /1 t .• t
Type of Inspection:
Address:
24 36 /nL1,
/'�
Date Called:
Special Instructions:
Date Wanted:
'A' i
o
a.m.
p.m.
Requester:
Phone No:
f'
•
3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 SouthcenterBlvd., #100, Tukwila, WA 98188 (206)431 - 3670
pproved per applicable codes. El Corrections required prior to approval.
Inspector:, Date:
In -oc Y
PERMIT NO.
- 7/17/
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
f
Project: J ,
Project: fe, .
Type of Inspection
� NJ
J A Z1
Address:
i- 1(3&
MA,
Date Called:
.
Special Instructions:
Date Wanted:
Requester:
Phone No: �y
1-5"3 3ta 27/5
INSPECTION RECORD AAA r)
Retain a copy with permit flag " W 4
INSPECTION NO. PERMIT NO: (�
CITY OF TUKWILA BUILDING DIVISION F-
6 3 0 0 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6
Approved per applicable codes. ['Corrections required prior to approval.
1 Il
COMMENTS:
Inspector: : ()
Date: [ s
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
'Receipt No.:
Date:
Project: C �` ��5 /
Type of Inspectigp:
\,_J
Address: ?
2 - if
- e �//
Date Called:
Special Instructions:
Date Wanted: 6 /
�%
a.m.
p.m.
Requester:
Phone No:
1
INSPECTION RECORD
Retain a copy with permit
#10V'190
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION V
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -
Approved per applicable codes. Corrections required prior to approval.
COMMENTS: 7/4
0 K - tt h z%.4,t €
GNU GI 5.e 1 .5144 d`.�r_ i ►" a ;#'
V1)-11
1J $6 4 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be
pa t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
•1\
Project:
Sprinklers:
Type of Insp ction:
Address: 0 3
Suite #:
. s .
M A t✓
Contact Person:
Special Instructions:
Permits:
Occupancy Type:
Phone No.:
Needs Shift Inspection: =
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
, .s
ill
INSPECTION NUMBER
n Approved per applicable codes.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA FIRE DEPARTMENT
Word /Inspection Record Form.Doc 1/13/06"
PERMIT NUMBERS
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
Corrections required prior to approval.
COMMENTS:
tivd� --- v IL
SP c , otc.
ro .
Inspector: 57
Date: -72/8 )
H rs.:
$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
T.F.D. Form F.P. 113
06 -05 -2008
PAUL LANDA
2932 NORTHWESTERN AV
RACINE WI 53404
RE: Permit Application No. M08 -008
2836 SOUTHCENTER MALL TUKW
Dear Permit Applicant:
In reviewing our current permit application files, it appears that your permit application applied for on 01/08/2008 , has not been
issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical
Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and
void. Your permit application expires on 07/06/2008 .
If you choose to pursue your project, a written request for extension of your application addressed to the Building Official,
demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/06/2008. If it is
determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date.
In the event we do not receive your written request for extension, your permit application will become null and void and your project
will require a new permit application, plans and specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
xc:
er Marshall
t Technician
Permit File No. M08 -008
City of Tukwila
Jim Haggerton, Mayor
epartment of Community Development Jack Pace, Director
6300 Southcenter Boulevard, Suite #100 o Tukwila, Washington 98188 a Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
ACTIVITY NUMBER: M08 -008 DATE: 01 -08 -08
PROJECT NAME: CLAIRE'S
SITE ADDRESS: 2836 SOUTHCENTER MALL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: I ��
Bung "Clivis
Public Works
Comments:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
Structural Review Required
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -28 -02
•
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 7 Incomplete n
lo -00
Planning Division
Permit Coordinator
No further Review Required
DATE:
DATE:
n
DUE DATE: 01-10 -08
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
DUE DATE: 02-07-08
Not Approved (attach comments) n
Permit Center Use Only .
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
AIREPI *000DA
Licensee Name
AIRE PRO INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
601771753
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
2921 MERIDIAN AVE E
Address 2
City
EDGEWOOD
County
PIERCE
State
WA
Zip
98372
Phone
2538482626
Status
ACTIVE
Specialty 1
HVAC/RFRG LTD ENERGY
Specialty 2
UNUSED
Effective Date
3/1/2000
Expiration Date
3/1/2010
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
RAEDESW967KM
Business Owner Information
Name
Role
Effective Date
Expiration Date
JENNINGS, RICHARD M
01/01/1980
RAEDER, SCOTT W
01/01/1980
JENNINGS, RICHARD
AGENT
01/01/1980
Look Up a Contractor, Electrl or Plumber License Detail
Washington State Department of Labor and Industries
Master Electrician Information
License
Name
Status
RAEDESW967KM
RAEDER, SCOTT W
ACTIVE
I
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
•
t
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= AIREPI *000DA 06/26/2008
SINGLE
DOUBLE
ABBR.
DESCRIPTION
J
•
RECTANGULAR DUCT
r f
i rr
•
ROUND DUCT
C (
•
45 DEG. TAP: USE AT BRANCH DUCTS ONLY
•
DUCT SPLIT W /DAMPER: USE AT ELBOWS AND TEES:
PROPORTION DUCT AREAS BY CFM 'S
G
•
CURVED ELBOW —MIN. RADIUS R: 1.5 WIDTH
•
90 DEG. ELBOW WITH SINGLE RADIUS TURNING VANES
+ 14
+— 1IIIII--
—
•
FLEXIBLE DUCT CONNECTION
1r
FD
FIRE DAMPER
7 r
/
r
BD
BALANCING DAMPER (USE O.B.D. UNLESS
NOTED OTHERWISE)
r
I
I
NEW TO EXISTING CONNECTION
7 4
•
SPiN —IN FLEX DUCT TAKE —OFF W /DAMPER
1
•
A
SA
SUPPLY AIR
•
/
EXH
EXHAUST AIR
•
r
RA
RETURN AIR
•
17_1
REL
RELIEF AIR
•��.
OSA
OUTSIDE AIR
•
Q X
T
THERMOSTAT X: UNIT OR ZONE NUMBER
•
TQ X
T
THERMOSTAT W /SHERWOOD GUARD
PER 2006 IMC SECTION 606
Install smoke detector to shut down air distribution
by VAV's when the total combined C F M of all
VAV's (to include other tenants) sharing the same
plenum space exceeds 2000 CFM.
(See IMC 606.2.2 for approved method of detection
DUCTWORK SYMBOLS
MECHANICAL PLAN
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS
AND ESTABLISH A DISCREPANCY RESOLUTION PROCEDURE.
2. ALL WORK SHALL BE SCHEDULE WITH LANDLORD'S FIELD
REPRESENTATIVE.
3. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOIST,
NOT FROM FLOOR BELOW OR ROOF DECK ABOVE.
4. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5' —O ".
5. MAINTAIN A MINIMUM OF 6" UNOBSTRUCTED CLEARANCE HEIGHT
IN RETURN AIR PLENUM ABOVE CEILING ALLOWING FOR AIR FLOW
BACK TO LANDLORD AIR CONDITIONING UNIT.
OUTSIDE AIR CALCULATION
SALES:
AREA = 1124 SF
REQUIRED VENTILATION RATE = 0.30 CFM /SF
CFM = 1124 SF x 0.30 CFM /SF
CFM = 337
STOCK /BACK AREA:
AREA = 161 SF
REQUIRED VENTILATION RATE = 0.15 CFM /SF
CFM = 161 SF x 0.15 CFM /SF
CFM = 24
RESTROOM:
WATER CLOSET (WC): 1
REQUIRED VENTILATION RATE = 75 CFM /WC
CFM = 1 WC x 75 CFM
CFM = 75
LANDLORD NOTES
TOTAL CFM REQUIRED = 436
TOTAL CFM PROVIDED = 440 (VIA MIN. S.A. SETTING OF VAV BOX)
CALCULATED AS PER 2006 I.M.C. SECTION 403, TABLE 403.3.
KEYED NOTES
0 6' —O" LONG, 2 —SLOT LD-1. BALANCE TO CFM NOTED.
® 24x24, 8 "0 NECK CD -1. BALANCE TO CFM NOTED.
24x24, 22x22 NECK RG -1
NEW TEMPERATURE SENSOR. MOUNT AT 48" A.F.F.
® NEW FAN POWERED VARIABLE AIR VOLUME BOX. FIELD VERIFY.
DUCT SMOKE DETECTOR.
6 "0 TOILET EXHAUST DUCT TO CONNECT TO LANDLORD'S EXISTING 8 "o
TOILET EXHAUST AIR DUCT. FIELD VERIFY EXACT POINT OF CONNECTION.
SCALE: 1/4" = 1' -0"
® NEW 14"93 SUPPLY AIR INLET DUCT TO CONNECT TO THE LANDLORD
PROVIDED 16" SUPPLY AIR INLET. FIELD VERIFY EXACT POINT OF
CONNECTION.
a
LANDLORD'S EXISTING 16 SUPPLY AIR INLET. FIELD VERIFY EXACT
POINT OF CONNECTION.
1D 6' -0" LONG, 2 —SLOT LG-1. SHALL BE USED FOR RETURN AIR.
City of Tukwila
BUILDING DIVISION
Pier review = ; _ . to emirs and omissions.
Approval of consfu docurnalts does not maize
the violation of any code orb. Receipt
of approved Field and conditions la acJmowledged:
BY
Dater (9' z °
P _- ;;wi')NS
No changes cl be made to the scope I .
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will .require a new plan submitla
and may include additional plan review fees. I
SEPARATE PERMIT
REQUIRED FOR:
❑ Mechanical
, ,Electrical
I Plumbing
as Piping
t .ity of Tukwila
DIVISION
ALOS
r
RECEIVED
CITY OF TUKWILA
JAN 0 8 2008
PE iivii 1' C: 1\1 l ER
COPYRIGHT NOTICE;
These drawings and specifications are copyrighted and
subject to copyright protection as an "architectural work"
under sec. 102 of the copyright act, 17 u.S.C. As
amended december 1990. The protection includes,
without limitation, the overall form, arrangement and
composition of spaces, and elements of the design.
Under such protection, unauthorized use of these
drawings and specifications may result in cessation of
construction, building seizure, and /or monetary liability.
t0
=
• as
lan
■ c
O t a
1
6 1 —
QO �
3N
DRAWN BY:
STORE NO.
6349
a
0
MOO
SCALE: 1 /4 " =1' -0"
STAFF
PROJECT No.: GL,R -07 -052
OM)
6
V
W
Mi
E
8
s
EXPIRES pg
DA
co mbar 21, 2001 SHEET:
12 of 11
MARK
AREA SERVED
MANUFACTURER
MODEL
CFM
E.S.P.
(W.C.)
MOTOR
(BACKDRAFT
DAMPER
DRIVE
HP
V /PH
EF -1
TOILET ROOM
BROAN
679
75
0.125
FRAC.
120 /1
YES
DIRECT
UNEAR GRILLE
TITUS
MLR -37
ALUMINUM
6' -0"
-
TYPE -2B FLANGE
LINEAR SLOT
NONE
CD -1
MARK
DESCRIPTION
MANUFACTURER
MODEL
MATERIAL
MODULE
PLAQUE
AC
BORDER
-
FRONT
- . DES
DAMPER
LD -1
LINEAR DIFFUSER
TITUS
ML -37
ALUMINUM
6' -0"
-
-E FLANGE B
LINEAR SLOT
NONE
LG -1
UNEAR GRILLE
TITUS
MLR -37
ALUMINUM
6' -0"
-
TYPE -2B FLANGE
LINEAR SLOT
NONE
CD -1
CEILING DIFFUSER
'TI TUS
DAT
STEEL
24 "x24"
13 "x13"
LAY -IN
3 -SLOT
OPPOSED
BLADE
RG -1
RETURN GRILLE
TITUS
23RL
STEEL
24 "x24"
-
LAY -IN
-
NONE
CALCULATED DESIGN HEATING LOAD
MBH 0
CALCULATED DESIGN COOLING LOAD
MBH 28.0
LANDLORD ALLOCATED AIR SUPPLY
MBH 1460
CALCULATED AIR SUPPLY
CFM 1100
MAKE -UP AIR SYSTEMS(S)(IF APPLICABLE)
CFM N/A
TOTAL AIR SUPPLY
CFM 1100
TOILET EXHAUST
CFM+ 75
SPECIAL EXHAUST
CFM 0
TOTAL EXHAUST
CFM+ 75
NEGATIVE /POSITIVE PRESSURE (AIR SUPPLY - EXHAUST)
CFM+ 1025
CALCULATED LOSS IN DUCTWORK
0.15
CALCULATED S.P. LOSS IN DIFFUSERS AND DAMPERS ETC.
0.15
TOTAL EXTERNAL STATIC PRESSURE IN WATER COLUMN
0.3
PLUMBING (EXISTING)
DOMESTIC H.W. HEATERS STORAGE
GALLONS 6
NUMBER OF W.C. FIXTURE UNITS
2.0 F.U.
NUMBER OF LAVATORY FIXTURES UNITS
0.5 F.U.
NUMBER OF COMMERCIAL SINK FIXTURE UNITS
0 F.U.
OTHER EQUIPMENT USAGE
GPM 0
NEW FAN POWERED VARIABLE AIR VOLUME BOX
VFR -EH -1418
14"
1100
440
440 1/2 208/1
5
208/1)
MARK
VAV -1
MANUFACTURER
ENVIRO --TEC
MODEL INLET SIZE
PRIMARY CFM
MAX.
MIN.
CFM
AN
HP
NOTES:
1. COORDINATE ALL NECESSARY CONTROLS WITH LANDLORDS REPRESENTATIVE.
2. VERIFY VOLTAGE/ PHASE WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING EQUIPMENT.
V/0
HEATER
KW V/0
NEW EXHAUST FAN SCHEDULE
NOTES:
1. HELD PAINT ALL DIFFUSERS AND GRILLES COLOR WHITE.
2. THE "DAT" CEILING DIFFUSER CAN BE SUBSTITUTED WITH AN "ONMI" MODEL IF THE "DAT" MODEL IS NOT
AVAILABLE.
REMARKS
SEE NOTES BELOW
NEW GRILLE, REGISTER, AND DIFFUSER SCHEDULE
ROOF (AREA IN SQ. FT.)
0
OUTSIDE WALL (AREA IN SQ. FT.)
0
GLASS SOLAR
GLASS TRANSMISSION
LIGHTING ( WATTS)
3253 x 3.412
PEOPLE ( #)
27 x 245 (ONE PERSON PER 50 SQ. FT. OF SALES AREA)
OUTSIDE AIR (SAME AS FOR HEATING) (CFM)
0
EQUIPMENT OR OTHER SPECIAL LOADS AS APPLICABLE
TOTAL SENSIBLE HEAT
PEOPLE (27) x 205
OUTSIDE AIR LATENT HEAT
OTHER SPECIAL LOADS AS APPLICABLE
TOTAL LATENT HEAT
GRAND TOTAL
MEP LOAD DATE TABULATION
SPACE # : 2150
NAME OF TENANT: CLAIRE'S
GROSS LEASED AREA IN SQ. FT. 1330
TAPE AROUND SNUGGLY Z
WRAPS PRIOR TO INSTALLING
LINE STRAP
FLEXIBLE DUCT
MAX. 4' -0" LENGTH
HEAT GAIN CALCULATION
MECHANICAL
GYP BOARD
CEILING
2"
0
_ 0
0
0
• 11099
6615
0
4774
-- 22488
• 5535
0
▪ 0
0
• 28023
ROUND S.A.
DUCTWORK ABOVE CEILING.
SEE PLAN FOR DUCT SIZE.
\__ 1" WIDE x 20 GA. STRAP W/
TIGHTENING SCREW
SECURE STRAP W/ SHEET
METAL SCREWS 3' O.C. MAX.
24 "x24" " TITUS" TRM -RAPID
MOUNT FRAME
24 "x24" "1ITUS" MODEL # DAT,
ROUND NECK (SEE SHEET M1
FOR NECK SIZE) BORDER TYPE
3- LAY -IN DIFFUSER
N.T.S.
SQUARE SUPPLY AIR DIFFUSER DETAIL
MECHANICAL GENERAL NOTES
1. ALL. WORK SHALL COMPLY WITH ALL APPUCABLE FEDERAL, STATE AND
LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES HAVING JURISDICTION,
AND LANDLORD'S CRITERIA.
2. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLI-
CABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY; AND THE
MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRO-
DUCT APPLICATION AND INSTALLATION.
3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES,
DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK.
4. . PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE
SITE AND THOROUGHLY INSPECT ALL. EXISTING CONDITIONS TO INSURE THAT
THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS
CAN BE INSTALLED AS INDICATED.
5. DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH
ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN
ALL ELBOWS; AND MANUAL VOLUME DAMPERS IN ALL BRANCHES, SPLIT -
PER DAMPERS, AIR EQUAUZERS, EXTRACTORS, AND SIMILAR DEVICES
WHEREVER NECESSARY TO PROPERLY BALANCE THE SYSTEM AND PRODUCE
A QUIET AND DRAFTLESS OPERATION.
6. DUCTWORK SHALL BE GALVANIZED SHEET METAL OF LOCK FORMING QUAUTY.
24 GAUGE UP TO 30 ", 22 GAUGE - 30" AND OVER.
ALTERNATE: STANDARD SPIRAL ROUND GALVANIZED SHEET METAL DUCTWORK.
24 GAUGE UP TO 36 "0, 22 GAUGE -36" TO 50 ".
FIRST 15 FT. OF DUCT FROM EQUIPMENT SHALL BE LINED 1" HEAVY DENSITY
ACOUSTICAL INSULATION.
7. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX "M -KE" WITH ONE INCH EXTER-
NAL INSULATION FINISHED WITH A VAPOR BARRIER, U.L AND 90A LISTED,
SHALL BE EQUIPPED WITH DAMPER - EXTRACTOR AT THE SHEETMETAL DUCT
AND CIRCULAR COLLAR AT THE DIFFUSER, MECHANICALLY SECURED.
FLE IBL D CTWORK SHALL NOT XC ED ET 1 L NGTH; :ENIS SHALL
NOT RESTRICT THE INSIDE CROSS - SECTIONAL AREA OF THE DUCT; AND
CONNECTION SHALL BE MADE AS DIRECT AS POSSIBLE TO THE MAIN SUPPLY.
9 ALL WORK SHALL BE LOCATED TO AVOID CONFLICTS WITH OTHER TRADES
PROVIDE ADEQUATE CLEARANCE FOR ARCHITECTURAL DESIGN, PROPER
OPERATION AND SERVICE OF EQUIPMENT.
10. PROVIDE A READY -TO -USE SYSTEM WITH ALL WORK GUARANTEED IN WRI-
THING AGAINST DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF
ONE YEAR FROM TURN OVER TO OWNER.
11. CONDENSATE DRAINS: TYPE "M" HARD DRAWN COPPER FOR
LINES 1" AND SMALLER, "DWV" HARD DRAWN COPPER FOR 1 -1/4" AND
LARGER, CONFORMING TO ASTM B88 -72. WROUGHT COPPER FITTINGS,
DRAINAGE TYPE FOR LINES 1-1/4" AND LARGER. SOLDER WITH 50/50 SOLDER.
12. DUCTWORK SHALL BE "FACTORY MADE" CLASS 1 GALVANIZED SHEET METAL
WITH IRON SUPPORTS SECURED TO OVERHEAD MEMBERS AT 5' -O" DUCTWORK
MATERIALS SHALL BE PER INTERNATIONAL MECHANICAL CODE, 2006.
13. PROVIDE AS PART OF THE MECHANICAL CONTRACT SERVICES OF AN INDEPENDENT
AIR /WATER BALANCING CONTRACTOR CERTIFIED BY THE ASSOCIATED AIR
BALANCE COUNCIL. SUBMIT 3 COPIES OF THE BALANCE REPORT TO ARCHITECT /OWNER.
14. PROVIDE DUCT SMOKE DETECTORS IN SA DUCTS, TO OVER RIDE UNIT AND
PROVIDE SHUTDOWN WHEN UPON DETECTION OF SMOKE.
THE DUCT SMOKE DETECTOR SHALL BE CONNECTED TO THE FiRE ALARM SYSTEM. THE
ACTUATION OF THE SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND AUDIBLE
SIGNAL AT A CONSTANTLY ATTENDED LOCATION.
15. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE ALL APPLICABLE BUILDING
CODES, NFPA -90A AIR CONDITIONING AND VENTILATION, NFPA -91 BLOWER AND
EXHAUST SYSTEM, ASHRAE GUIDE - EQUIPMENT, SYSTEM AND APPUCA11ONS,
SMACNA - LOW VELOCITY DUCT CONSTRUCTION AND NFPA 101 SAFETY I.Q LIEF.
FROM FIRE IN BUILDING. EV. .,.._ )
CODE COMPLIANCE
APPRCVED
HVAC NOTES
1. ALL WORK TO BE AS PER THE L.L. SPECS, ALL LOCAL CODES, RULES AND REGULATIONS.
ALL WORK TO BE AS PER ASHRAE AND SMACNA GUIDEUNES.
2. ALL DUCT SIZES SHOWN ARE CLEAR INSIDE. ALL DUCTS TO BE SHEET METAL DUCTS AS PER
ASHRAE AND SMACNA GUIDELINES.
3. PROVIDE NECESSARY TURNING VANES, SPUTTER DAMPERS, VOLUME EXTRACTORS AND
OTHER FEATURES NEEDED FOR A SMOOTH AND CONTROLLED FLOW OF AIR.
4. LOCATIONS SHOWN OF HVAC EQUIPMENT AND DUCTS ARE SCHEMATIC ONLY. VERIFY
STRUCTURAL DETAILS AND OTHER DETAILS THAT WILL AFFECT ROUTING AND PLACEMENT OF
THESE COMPONENTS. IF MORE SUPPORTS ARE NEEDED FOR HVAC EQUIPMENT, COORDINATE
WITH THE ARCHITECT.
5. PROVIDE PROPER DUCT TRANSITIONS FOR ACTUAL HVAC UNITS INSTALLED. ROOF
PENETRATIONS, IF ANY, TO BE MADE AS PER L.L. SPECS. VERIFY DETAILS WITH L.L..
6. PROVIDE AND INSTALL THERMOSTATS AT LOCATIONS AS DIRECTED BY THE ARCHITECT.
7. COORDINATE ACTUAL LOCATIONS OF DIFFUSERS, REGISTERS AND GRILLES WITH CEIUNG
DETAILS AND OTHER FEATURES SUCH AS UGHTING FIXTURES ETC. THAT MAY AFFECT
PLACEMENT OF THE HVAC SYSTEM COMPONENTS.
8. GENERAL CONTRACTOR SHALL SUPPLY ALL EQUIPMENT CONTROLS AND WIRING.
COORDINATE WITH MALL REPRESENTATIVE FOR INTERLOCKING WITH MALL CONTROL
SYSTEM (AS REQUIRED).
9. CONTRACTOR SHALL SUBMIT MANUFACTURER'S SHOP DRAWINGS ON ALL HVAC EQUIPMENT
AND DUCTWORK FOR REVIEW BEFORE INSTALLATION.
10. PROVIDE APPROVED FIRE DAMPERS WITH ACCESS PANELS AT ALL PENETRATIONS OF
FIRE RATED PARTITIONS, WALLS AND CEILINGS AS REQUIRED BY CODE.
11. HANGERS -4" AND SMALLER GRINELL #115.
12. UPON COMPLETION OF WORK, MECHANICAL CONTRACTOR TO FIELD VERITY THAT BOTH
HEATING AND COOLING CYCLES ARE FULLY FUNCTIONAL AND PROVIDE REPORT TO
CLAIRE'S CONSTRUCTION MANAGER.
13. INSULATE NECK, THROATS AND COLLARS OF SUPPLY OUTLETS ABOVE CEILING.
NOTE:
PRIOR TO CONSTRUCTION/ BID THE CONTRACTOR
SHALL VISIT THIS SITE AND FIELD VERIFY THE
EXISTING LOCATIONS AND SIZES OF ANY LANDLORD
PROVIDED, OR EXISTING, OUTSIDE AIR INTAKES
THROUGH ROOF, LANDLORD PROVIDED CHILLED /HOT WATER
PIPING MAINS, TOILET EXHAUST MAINS, OUTSIDE AIR DUCTWORK,
CONDENSATE LINE MAINS, ETC.
THE CONTRACTOR SHALL FIELD VERIFY ANY/ CONDITIONS
WHICH MAY CONFLICT WITH THE DESIGN SHOWN ON
THESE PLANS. NOTIFY ARCHITECT IMMEDIATELY.
27'lr_ -. ?? 7- 74.4.. yp:EF �7;7^4
ai •)
7!40; {
RECEIVED
CITY OF TUKWILA
JAN 0 8 ZJu,i
HIHivu I CEC\l I ER
COPYRIGHT NOTICE;
These drawings and specifications are copyrighted and
subject to copyright protection as an "architectural work"
under sec. 102 of the copyright act, 17 u.S.C. As
amended december 1990. The protection includes.
without limitation, the overall form, arrangement and
composition of spaces, and elements of the design.
Under such protection, unauthorized use of these
drawings and specifications may result in cessation of
construction, building seizure, and /or monetary liability.
SCALE:
DRAWN BY
6349
STORE NO.
cn
a
0
EXPIRES Cg
1 /4 " =1'" -- 0"
STAFF
0
a
1-
0
n
DATE: November 21, 2001 SHEET:
0
op o
en u
s
o
M2
PROJECT No.: GL-R -01-052 13 of 1 1