Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-018 - WESTFIELD SOUTHCENTER MALL - SARKU JAPAN
SARKU JAPAN 2600 SOUTHCENTER MALL FC -3 M08 -018 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: ioc: IMC -10/06 CitA►f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2600 SOUTHCENTER MALL TUKW Value of Mechanical: $42,500.00 Type of Fire Protection: SARKU JAPAN 2600 SOUTHCENTER MALL FC -3 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Contractor: Name: K & D MECHANICAL INC Address: 1911 SW CAMPUS DR #321 , FEDERAL WAY Contractor License No: KDMECI *008CJ MECHANICAL PERMIT Contact Person: Name: TIM PETTIFER Address: 7650 BIRCHMOUNT RD , MARKHAM, ONTARIO, CANADA DESCRIPTION OF WORK: • LSTALL 2 HOODS WITH DUCTING TO EXHAUST FANS ON ROOF. INSTALL DUCTING FROM EZOOFTOP UNITS TO FINISHED SPACE BELOW. Furnace: <100K BTU >100K BTU :7oor Furnace duspended/Wall/Floor Mounted Heater appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System :food and Duct Incinerator: Domestic Commercial/Industrial EOUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 1 0 0 2 0 2 0 0 * * continued on next page ** M08 -018 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 416 - 891 -3327 Phone: 253 - 945 -8204 Expiration Date: 02/21/2010 M08 -018 04/21/2008 10/18/2008 Fees Collected: $649.90 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 04 -21 -2008 Permit Center Authorized Signature: Signature. ioc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Print Name: B (L!¢ G S- 0 Permit Number: M08 -018 Issue Date: 04/21/2008 Permit Expires On: 10/18/2008 Date: IT I (vl 1/ [ hereby certify that I have read and ex knu ed this permit and know the same to be true and correct. All provisions of law and ordinances 4overnin this work will be complied wi`thif whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the;- • ice - . ork. I am authorized to sign and obtain this mechanical permit. Date: 1/- this permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended Dr abandoned for a period of 180 days from the last inspection. M08 -018 Printed: 04 -21 -2008 • • City of Tukwila 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Permit Number: M08 -018 Address: 2600 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 01/16/2008 Tenant: SARKU JAPAN Issue Date: 04/21/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of his requirement. 3: Manufacturers installation instructions shall be available on the job site at the time of inspection. a: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, my violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila ;hall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the 3uilding Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the 'ollowing concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned h the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be :quipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the ioc: Cond -10/06 M08 -018 Printed: 04 -21 -2008 • • • • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance With the requirements of the listing. (NFPA 96, 10.2.3) 22: Local U.L. central station supervision is required. (City Ordinance #2051) 23: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 24: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 25: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation Instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 26: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 27: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the nazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 28: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that ndicates the month and year that the inspection was performed and shall identify the company or person performing the iervice. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the . nspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) ioc: Cond -10/06 M08 -018 Printed: 04 -21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 30: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 31: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. lac: Cond -10/06 * * continued on next page ** M08 -018 Printed: 04 -21 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1 hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. S ignature: Print Name: Pp 7 T ) t e-!¢ 0 loc: Cond -10/06 M08 -018 Date: y`s. /a ordinances governing or local laws regulating Printed: 04 -21 -2008 ■ CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.cltukwila.wa.us SITE LOCATION �^ ` King Co Assessor's Tax No.: °i/ 3 & 4 1 00 ( f� Site Address: 1 0 ri CeAt 4' Tk,U \1 1(.�, t I& I(A SuiiL Number: F�' Floor: 2 Tenant Name: . So o; , J Jc i;rl '.r` / I�'j ScAr tA -j New Tenant: jiq Yes ❑..No Property Owners Name: 1 "/ E. A ;Ai +, Mailing Address: i 1 (p CJ 1 11J i !1 < k t C' a l 1)4 1 H4 -Roo- CONTACT CONTACT PERSON - who do we contact when your permit is ready to be issued Name: l i rY) E -Mail Address: 1 pe'.d t Fef Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: I c t j ( yr tTitt'y ft ,t r GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))` Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: ARCHITECT OF RECORD - All plans must be wet stamped by Architect`of Reeord Company Name: 1 1 ! P.(r I r c, I i 4,f-titre Mailing Address: SOO 5 I J Ro c l a e e, 6., Contact Person: //are ,,f'- a ri E -Mail Address: f znia&N �i . ���r; C` —) Cr.X11- ,tG_f7? .Mori ENGINEER OF RECORD -All plans must be wet stamped by Engineer of Record s t,,1 R.i:l. 0... 1--01 5 4-.4 - P l Contact Person: i i ✓ f`1a r> v102- r� e _ E -Mail Address: t '� Fo ) / ;near —�rth 1 tT,(' .64re- , ;ni Q:\Applications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised- 9 -2006 bh Company Name: Mailing Address: • Building. Permit No. Mechanical Permit No Plumbing /Gas Permit No., Ttv0 Public Permit No Project No.- 'For office use only) State L Os A - n � � Ft-- q 0 2.- City State Zip Day Telephone: 1 1 " ?? , (- 3 7 3 1 :7 i hi trl I`-- RG61, City r� State Zip Fax Number: q 74' o 47-1 Zip Expiration Date: 1 rvi. n TX 7's06a City ' j State Zip Q Day Telephone: 17 2- c i z,9 -9 224 Fax Number: q 7 2. ` 929 ?04, -- r)( _T5-o(e) Irv; 1'13 City ' State , Zip Day Telephone: 9 ' 2,114-- ( 12.2_, Fax Number: q 2 - ( 2- —qc f Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct 2 Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater - Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct ', Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System i Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 6 Incinerator — Comm/Ind [MECHANICAL PERMIT INFORMATION - 206 - 431 -367Q MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ / ' - t .1 � � r 00 Scope of Work (please provide detailed information): MK. 2. exln vt On MO - ietiCh I 50Pc e Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric l( Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q: 4kpplicationsWorms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY T 1 L , OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE • +at'� ►< �J/ AGENT: Signature: 1 Ag✓r Date: Day Telephone: Print Name: Mailing Address: Date Application Accepted: G_ Q:'Applications\Forms- Applications On Line3-2006 - Permit Application.doc Revised: 9 -2006 bh Date Application Expires: City state Zip Staff Initials: Page 6 of 6 Parcel No.: 6364200010 Permit Number: M08 -018 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/16/2008 Applicant: SARKU JAPAN Issue Date: Receipt No.: Initials: User ID: Payee: R08 -01252 JEM 1165 ACCOUNT ITEM LIST: Description Receipt -06 . City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us K & D MECHANICAL INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 6364 525.92 MECHANICAL - NONRES RECEIPT Account Code Current Pmts 000/322.100 525.92 Total: $525.92 Payment Amount: $525.92 Payment Date: 04/21/2008 01:21 PM Balance: $0.00 1393 04/21 9710 TOTAL 525.92 Printed: 04 -21 -2008 Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUICW Suite No: Applicant: SARKU JAPAN Receipt No.: R08 -00136 [nitials: WER Jser ID: 1655 ?ayee: kCCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us WOODBURN CONSTRUCTION RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 2635 123.98 Account Code Current Pmts 000/345.830 123.98 Total: $123.98 • Permit Number: M08 -018 Status: PENDING Applied Date: 01/16/2008 Issue Date: Payment Amount: $123.98 Payment Date: 01/16/2008 02:53 PM Balance: $525.92 7321 01/16 9710 TOTAL 186243 Pc: Receipt-06 Printed: 01 -16 -2008 Project: Type of Inspection: _ U Address: A00 Fc- 3 /y4 i( I Date Called: Special Instructions: Date Wanted: a. 2 ( 1-4" P.m Requester: ("/drile( � Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Approved per applicable codes. El Corrections required prior to approval. COMMENTS: �,, f ,•I r rs (4) dr9'^ 5 (Qr- -p/l(-e p.tr4 if cormtlrlc /r LJ $60.00 REI SPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: NTS: COMMENTS: Type of Inspection: ' r--- / / � `` 1) M /., c 4 f I efigi 4 4..- 1� arm 14'1 "')S 9 r.r., Cf.(., /n 1 iti7 7 as. t //C�I ( F4 444tr,) 3) &5 Ahs. 1 .S1 r..4 4,..4.....,..k, rAat St 5,, it, Special Instructions: Date Wanted: 9 — Z 7-4 e p .m. Requester: tr Phone No: Project: S AekV J 4 Op 1 Type of Inspection: ' r--- Address: boa re - 3 tf r Date Called: Special Instructions: Date Wanted: 9 — Z 7-4 e p .m. Requester: tr Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. Igo INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36]0 ❑ Approved per applicable codes. © Corrections required prior to approval. Inspector: Date: 7 l —� LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: _ . ..,.� .� Project: K `i -'['' K a-Q .1 Type of Inspection: S/'rl t 4 Sh....4-,L9 UJ En Address: 'ZCo0 yam' f i Date Called: Special Instructions: Date Wanted: 1 1 14 6 10 T a.m. p.m. Requester: Phone No: f j O . 3 -113 to 324, 14- INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 gi Approved per applicable codes. Corrections required prior to approval. COMMENTS: h o _ (00 — PASS -d Al )4 -1 IQ4 •L 9. 1 h < -eS AN l tar t nspector Date: " V ica /cR El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: T All tl altr.-e, I 14 plAre, 4.4.1 1T ,5.0/ 9 st oo Ta f 9 (.. „i fi 1 /4 0 ftZ 4 -5•, 3 n� �` 16 iti4 1 "it”- c"- p Sras 06/5�,'kc� h al' 1 Lwsic Ilei Cluck 9A (g.,...1 Special Instructions: - Date Want se —DP, •rfi•` 1p.m- Requester: Project: Type o Inspection: Address: Q600 m47 Date Called: Special Instructions: - Date Want se —DP, •rfi•` 1p.m- Requester: Phone No: -- 6;32 4 0 INSPECTION RECORD Retain a copy with permit PER IT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION tz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 06)43 1 -3670 Approved per applicable codes. Corrections required prior to approval. nspector: Date: _ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: Type o s ctior 6 /A Sc ,7r. cT ASS /61 P.---it Date Called: ¶/ S 121 i; ,r , Date Wanted: L -- ? mo t --10 Fri 1,, 1,)‘,1 (Off . 7- Dr Nr-.r.. ,. c G - 3Z 3 �j I.� wa.k ayd 4 16113, o2 ( Project: n { � Type o s ctior Address: - 2( . '0o YV1 A L ( Date Called: Special Instructions: Date Wanted: L -- ? mo t --10 Requester: Phone No t3 -? - 3Z 3 a INSPECTION NO. INSPECTION RECORD Retain a copy with permit 'nu/3 -0 le PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2 06)43 1 -3670 IZ Approved per applicable codes. LJ Corrections required prior to approval. Inspector: T 2f . fl $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: ti .__ ;..� _��. COMMENTS: Ol Sf'rraI 1 /44 olc 7 .2NScIafZ X (;ru3ca d NN f /I/ d f✓fM 4 Tif lip/ T...,4/4-1r7)( Special Instructions: Date Wanted: 4- 1`4A De. P.m. Requester: Phone No c©3 - 793 -G32 Project: TT _ .7A /kl/ JI�f vet Type of Inspectio : LL R2 h, h ,e4 Address: I 2 PO SDJ4 Cy.3e rill Date Called: Special Instructions: Date Wanted: 4- 1`4A De. P.m. Requester: Phone No c©3 - 793 -G32 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 LI Approved per applicable codes. El Corrections required prior to approval. Inspector: Date: D $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: COMMENTS: Sprinklers: Type of Inspection: A t - q fri rz4 Address: 4 c,, 0,3 S c Suite #: F c _ 3 17„,x.4- °Le . -4-es-A-- ck. (Io 4 d at -c y c ( ocit 1 - '" /J f c16 of c�-j� i+ e.S..) G to di h o kzz. L 6 1 u vim-, S h tat 't rt' t `. -,..:'' C k c c k e o o P Se 6 0 G ,-+ A ru 'v 62 I A v'Lt '1 0 l < . Project: q rU Sprinklers: Type of Inspection: A t - q fri rz4 Address: 4 c,, 0,3 S c Suite #: F c _ 3 c i ( Contact Person: & k f3gv*L\ Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 / - 018 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. Inspector: A Date: j —/ Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 COMMENTS: Sprinklers: � Ty�e� of I coon: e( T A q ,mo t . Address: N, C.,a c , Suite #: fC - 3 . ` . p -.n,i- _ .,_.. 71A . n (c__ Special Instructions: Phone No.: 1-j j" > __ q or� (r -f° �c 1 A1W L —0g..., B 1 i �� (': 0nit r p ci 1- IL N L1c t.L.t t, )/ti (..ttryr -j ,41,,44,74% -..... prc-4t'0zk+ o K.1 , • 4 )� 7 v1 � -`�.0`)CV(. may) 1- t1,y / n k. 1 44., f ., ,. — V Project .+ P � c( Sprinklers: � Ty�e� of I coon: e( T A q ,mo t . Address: N, C.,a c , Suite #: fC - 3 . ` . p -.n,i- _ .,_.. Contact Pers : Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER A• proved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Word /Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. Inspector: Date: 7 / y A,e Hrs.. n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 • �'r ` rmi t Non .ANF & ASSOCIATES, APR 1 6 2008 April 7, 2008 Westfield Design & Construction 633 South Center Trailer 43 Seattle, CA 98188 Attn: Bryan Low, Tenant Coordinator RE: HVAC Equipments on Level 3 South Center, Tukwila, WA Dear. Bryan: Sincerely yours, ANF & Associates Michael H. Wang, P.E. Associate RECEIVED , 0) CITY OF TUKWI )•2603 25966 ccw Please call us should you have any questions regarding the above. Letter to Westfield 0 i",e tli.t(' Level s,ar South Grote !J.di dated 4- 7,2005 guristtltingg §tKvctural Engineers We have completed our review of the level 3 floor framings at the designated HVAC equipment areas based on the following criteria: 1) Maximum single equipment weight of 1,500 lbs with a plan area of 6 square feet minimum. 2) There is no floor opening required under the equipment. 3) Minimum clearance between equipments is 3' -0" on 4 sides typical. Our review shows that the level 3 floor framings at the designated HVAC equipment areas can safely support the HVAC equipments if the criteria as mentioned above .are met. Level 3 floor framings under the equipments which do not meet the criteria as mentioned above shall be reviewed and reinforced as required by a professional engineer registered in the state of Washington. 3ERMIT CEN7E9.dster Ave.. Suite 1 18 • Flair Commerce Crater • El Monte, CA 91731 • Td: (626)448 -8182 • Fax (626)448 -8092 CORRECTION og 411 LTR #_I_ 1 MECH. CURB -- — PER MECHANICAL DRAWINGS CONC. TOPPING — OVER METAL DECK REVIEWED FOR CODE COMPLIANCE AlltPROVED APR 1 ' MIR ANF & ASSOCIATES Consulting StrUcturel Engineess P4 A-A BUILDING Ity Of Tuft di 1:3,VISION, RECEIVED CITY OF TUKWILA APR '1 6 2008 PERMIT CENTER Th1 (626)4484182, Fax: (626) 4484092 Inft6811pmballlt 9420 Talstar Avenue, Suite 118, El Monte, CA 91731 RILE, C N� pinr.stpr C8x11.5 TYP. - •••. '■ HILTI '-.--- -'; - 5/tro KWIK EXP. BOLT I • x4 EMBED. (ICBO# 4780) .1! A l - EDGE OF NEW OPEN'G -PL 1/4x8 • MAX C10x15.3 - OR W12x14 PL.1/4x8- NOTE (E)STL. BM.— DO NOT OVERCUT OF CONCRETE FLOOR OPEN`G CORE DRILL 4 OPEN'G © CORNERS & THEN SAWCUT THE REST OF OPEN PY Sc)turt-f-Cc.--to1y11- ,,, 't TYP. CONC. FLOOR OPENING DETAIL Na 6'—O" MAX. • 3/16:- SECTION B-B lttrlrrS - FL I I-- A7'74- sfo.S3 a OP - • B 0 Li 0 z 0 0 w 0 cc • - • FLOOR BEAMS SEE PLAN 3/161 6 PLAN r W/1" RETURN 2 ,._142" 3/16 ,JYP• SK1-031008 CORRECTION LTR# ANF T l (626) 4484182 ,o Jos Na 52.-- + D t11 \Z` 1��'C +.S Faa(626)448-8092 $DLLTm c.�4!`IUTe'/l� By Dy Consulting Structural Engineers E-ma11 snt1588(�prebdl mt t . ' � ✓ 1 , ( A -J A DATA 3 _I a SH. OF 9420 TeLrtar AMMO, Suite 118, El Mamie, CA 91731 METAL DECK W/- CONC. FILL SINGLE OPENING ([3 ) GROUP OF OPEN'GS NOTES: 1. DO NOT CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPENINGS NOT LARGER THAN 8" DIAMETER OR 8" SQUARE REQUIRE NO ANGLES. 3. CONC. OPENINGS OR GROUP OF OPENING EXCEEDING 16" OR CUTTING 2 BOTTOM FLUTES REQUIRE SECONDARY BEAM REINFORCEMENT AS PER DETAIL SK 1- 031008 TYP. METAL DECK ROOF FLOOR OPEN G W/ CONC. TOPPING (N) L3x3x1/4 W/5/8 "0 KWIK BOLT II TO BETTOM OF FLUTE ®12 "O.C. WITH 4 1/2" EMBED. SK2- 031008 Project Info Project Address Sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Department Use Tukwila ,Wa 98188 Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ;SUM 2006 Washington State Nonresidential Energy Code Compliance Forms FILE C n�6 IX PerM RED E �pNCE CODE COMPLIANCE APPRO VE APR 1 200% IL Of Tukwila AN IN DM Revised July 2007 R.EC l JAN 1 7 2008 PERMIT CEN I b Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU Lennox LGA06082B 60000 2000 300 12.50 na Roof Captiveaire A2 -D.500 205000 4358 na 205000 164000 80.000 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 80.000 RTU Lennox LGA060828 78000 2000 300 78000 62000 MUAl Captiveaire A2 -D.500 205000 4358 na 205000 164000 80.000 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM SP1 HP /BHP Flow Control Location of Service EF1 Captiveaire BRE -20 3229 1. 00 1.50 CV kitchen Roof EF2 Captiveaire ERE -13 1600 1.00 1.00 CV kitchen Roof Project Info Project Address Sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Dept. Use Tukwila ,Wa 98188 Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Mechanical Summary MECH -SUM Project Description Briefly describe mechanical system type and features. E Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 t lf available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Compliance Option 0 Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: (— Constant vol? n Air cooled? U Packaged sys? 0 <20,000 Btuh? _f Split system? Economizer included? If Heating Only: 7 <5000 cfm? u <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only No Reference Section 1421 Yes – Heating /Cooling or Cooling Only otal Ca . wo economize <240,000 Btuh or 10 %? Simple System Allowed (section 1420) Reference Section 1423,, • Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location 4 - Fill out this line on PRJ -SUM Applicant Address: s - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu/h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency 4 - Fill out this line on PRJ -SUM Applicant Address: s - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM SPA HP /BHP Flow Control Location of Service Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: s - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM Project Info Project Address Sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Dept. Use Tukwila ,Wa 98188 Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: s - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. 1 1f available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. 4 COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). Revised July 2007 Compliance Option O Simple System O Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling n Constant vol? E Air cooled? Packaged sys? <20,000 Btuh? or Cooling Only: E Split system? Economizer included? If Heating Only: E <5000 cfm? E <70% outside air? ,Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only No 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 Yes — otal Ca . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Simple System 1, Allowed (section 1420) Reference Section 1423) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - Complex Systems Checklist MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Sarku Japan Date 1/3/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH- CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup C Start Here v Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G Yes 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input? 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. as/Oil Fuma input >_ 225,000 tuh or Gas /O' 't Heat Air System Serving Multiple Zones? apacity of H Heating System > 00,000 Btuh Yes 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Yes Section 1432.2.1 Supply Air Reset Controls Required Yes No Section 1432.2.2 Hot Water Supply Temperature Reset Required 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - Complex Systems (back) j MECH- COMP 2006 Washington State Nonresidential Energy Code Compliance Forms � 0% Air Econ Provided? Section 1413 Yes Total Clg Capacity w/ Water Econo 500 Tons otorInd.! qpmt. Coved by Tbl 14- 1A -14- 1G? Section 1436 50% Effective Heat Recovery Required Multi -speed Motor in Multi - eed system 0 Yes Yes • DONE Yes _÷ Yes tal Cap. cono <= 480,00 Btuh or 20% of otal Cap.? Yes Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating /Recooling Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes No—* T Section 1433 Economizer Required Yes stem or Zon w/ Simultaneous Htg. & Clg.? Application Involves Variable Flow? Section 1437 Motors Must Meet Efficiencies in Table 14-4 Section 1438 Variable Flow Devices Required Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Revised July 2007 Open Motors Closed Motors 3,600 1 1,800 I 1,200 3,600 1 1,800 I 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full-Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2006 Washington State Nonresidential Energ Code Com • !lance Form Sarku Japan Type (open /closed) Description of Application or Use Date For Building Department Use Synch. Speed 1/3/2008 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14 -1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. Revised July 2007 M echanical Permit Plans Che ,; �, MECH; 2006 Washington State Nonresidential Energy Code Compliance Forms • Revised -CHK July 2007 Project Address sarku Japan !Date 1/3/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability Code (yes, no, n.a.) Section Component Information Required I Location on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance yes 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket Toss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage n.a. 1412.4.2 Optimum Start Indicate optimum start controls n. a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n . a . 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers no 1413.1 Air Econo Operation Indicate 100% capability on schedule no 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb no 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance no 1413.3 Integrated operation Indicate capability for partial cooling no 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements no 1416.2.1 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing no 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training no 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank no 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover If "no" is circled for anv question. provide explanation! 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonreside Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply ntial Energy Code Compliance Form Mechanical Permit Plans C;hecklist ME -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures 011 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonreside Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for fumaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity ( nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply ntial Energy Code Compliance Form Mechanical Permit Plans C;hecklist ME -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and intemal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry -bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures 011 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include 1. Within the HVAC equipment. microprocessor controls that minimize supplemental heat usage during start -up, set- 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu /h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) 1 February 4, 2008 Tim Pettifer 7650 Birchmount Road Markham Ontario, Canada L3R6B9 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -018 Sarku Japan — 2600 Southcenter Mall, Suite FC -3 Dear Mr. Pettifer, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Si; cerely, olt Permit Coordinator encl xc: File No. M08 -018 • Ciiy of Tukwila Department of Community Development Jack Pace, Director �1- P:\Permit Center \Correction Letters\2008\M08 -018 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Date: February 1, 2008 Project Name: Sarku Japan Permit #: M08 -018 Plan Review: Allen Johannessen, Plans Examiner • Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets- shall be original signed wet stamped, not copied.) 1. Mechanical equipment mounted on roofs exceeding 400 pounds shall require an engineer's analysis with calculations to show the roof structural members are sufficient for the additional loads imposed by the combined mechanical equipment. Provide details with the engineer's calculations. All engineer's documents shall be original wet stamped and signed by the engineer. 2. Plan shows grease drain down into the building. Provide a design or method that shall conform to the mechanical code where drainage of grease shall be captured in an approved grease reservoir capable of being maintained regularly. If a pipe is to be used, provide specifications to show pipes type, size and provide a method where grease shall not be allowed to buildup and clog the pipe. Identify where the pipe shall drain to. (IMC 506.5.2) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: M08 -018 DATE: 04 -16 -08 PROJECT NAME: SARKU JAPAN SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -3 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil.fng Cra An Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 HERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP Structural Incomplete ❑ Structural Review Required Approved Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention n Planning Division E DATE: DATE: Permit Coordinator No further Review Required n DUE DATE: 04 -1 7 -08 Not Applicable ❑ n DUE DATE: 051508 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -018 DATE: 01 -17 -08 PROJECT NAME: SARKU JAPAN SITE ADDRESS: 2600 SOUTHCENTER MALL FC -3 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DE ART ENTS: r Oat Buil g iin Public Works n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: REVIEWER'S INITIALS: Fire Preven Ion Structural Incomplete APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n Planning Division Permit Coordinator DUE DATE: 01 -22 -08 Not Applicable Permit Center Use Only _ . INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required DATE: DATE: n DUE DATE: 02 -19 -08 n Not Approved (attach comments) e Permit .•• Cer�. nter Use.Only ; ' • ° �:.. ` • • . - a . s is � CORRECTION LETTER MAILE D: • -2 * Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: tfri 1(Q 6 Project Name: Project Address: Contact Person: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc Plan Check/Permit Number: ❑( Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M Mullet, Mayor Steve Lancaster, Director RECENE CITY OF TU LA APR 1: 6 2008 PERMIT CENTER 7A J A 9a-V 0-Le (90 ' iti k M-tc n- ,Ai fr1 +Z - AA LV4 t L Mx G'l/- Phone Number: CD3 1 Summary of Revision: Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev' ion Received at the City of Tukwila Permit enter by: Entered in Permits Plus on 0 L la \applications\fbrms- applications on line\revision submittal Created: 8-13 -2004 Revised: iffm# t r r r-n 1�9 u Tr I1 /�t� `CV AvLVt eta ALT-. License Information License KDMECI *008CJ Licensee Name K & D MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601994103 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 1911 S W CAMPUS DR. 321 Address 2 City FEDERAL WAY County KING State WA Zip 98023 Phone 2539458204 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 2/11/2000 Expiration Date 2/21/2010 Suspend Date Separation Date Parent Company Previous License Next License WESTEMS921BG Associated License Business Owner Information Name Role Effective Date Expiration Date DAHLEN, JIM AGENT 02/11/2000 KACSO, OTTO PRESIDENT 02/11/2000 DAHLEN, JIM VICE PRESIDENT 02/11/2000 Look Up a Contractor, Electian or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date OHIO CAS INS Until Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= KDMECI* 008CJ 04/21/2008 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 SPACE# FC -3 KEY PLAN SARKU JAPAN SPACE FC -3 LEVEL: 02 OF F 3 816 1DliilirlL 1III1{IIIIIIIIllll111lllllf PROJECT INFORMATION: OWNER: SARKU JAPAN 7650 BIRCHM❑UNT ROAD, MARKHAM, ONTARIO CANADA L3R 6B9 TEL: (905) 474 -0710 FAX: (905) 474 -0421 PROJECT MANAGEMENT: SJ DESIGN BUILD INC, 7650 BIRCHM❑UNT ROAD, MARKHAM, ONTARIO CANADA L3R 6B9 TEL: (905) 415 -5700 FAX: (905) 474 -0421 ATTN,: TIM PETTIFER - DIRECTOR, CONSTRUCTION ARCHITECT: LINEAR ARCHITECTURE 5005 WEST ROYAL LANE, SUITE 144 IRVING, TX 75063 TEL: (972) 929 -9226 FAX: (972) 929 -9061 ATTN.: PHILIP KEMERY / MERCI KEMERY LANDLORD: WESTFIELD CORPORATION 14TH FLOOR 11601 WILSHIRE BLVD. LOS ANGELES, CA 90025 TEL.: (310) 893 -4761 FAX,: (310) 575 -5991 ATTN.: JOSH KIMMEL - PROJECT MANAGER MALL PROPERTY MANAGEMENT: WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 TEL.: (206) 246 -0423 ATTN.: ❑PERATI ❑NS MANAGER BUILDING DEPARTMENT: CITY OF TUKWILA 6300 SOUTHCENTER BLVD, #100 TUKWILA, W.) 98188 TEL,: (206) 431 -3670 FIRE DEPARTMENT: 444 ANDOVER PARK EAST TUKWILA, WA 98188 TEL.: (206) 575 -4404 EMAIL: tukf dadm@ci,tukwila,wa,us HEALTH DEPARTMENT: WASHINGT ❑N STATE DEPARTMENT OF HEALTH 101 ISRAEL RD. SE TUMWATER, WA 98501 TEL,: (360) 236 -4501 TENANT: TENANTS SARKU JAPAN ADDRESS: WESTFIELD SOUTHCENTER SPACE# FC3 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 APPLICABLE CODES CONSTRUCTION TYPE OCCUPANCY GROUP APPLICABLE CODES BUILDING — 2006 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS MECHANICAL — 2006 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS PLUMBING — 2006 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS ELECTRICAL — 2005 NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS ACCESSIBILITY — CHAPTER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER —FREE DESIGN ACCESS INCLUDING ICC/ ANSI A117.1 — 2003 ENERGY — 2006 WASHINGTON STATE ENERGY CODE FIRE — 2006 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS EXISTING CONSTRUCTION TYPE: TYPE II — B — UNPROTECTED NONCOMBUSTIBLE FULLY SPRINKLED PRIMARY OCCUPANCY: ABBR IIUTATI O \ S A.F.F. ACT. ADJ. A.C. ALT. ALUM. A B. APPROX. AWN. B.C. B.P. BM. BLK. B.S. B.W. BTM. BRK. BLDG. CAB. CPT. C.I. C.B. CLG. CEM. CTR. C.T. CHBD. C.O. CLO. COL COM. CONC. CONST. C.M.U. CONT. CONTR. C.J. C.TOP DEMO. DEPART. DTL DIA. DIM. DR. DTA DT.S. DN. DWG. D.F. EA. E. ELEC. E.C. E.H.D. E.W.C. ELEV. EN CL EQ. EQUIP. EXIST. E.J. EXP. EXT. E.G.C.B. ABOVE FINISH FLOOR ACOUSTICAL ADJUSTABLE AIR CONDITION /CONDI110NED/ CO N D Tf I0 N ER/ C O N D III O N I N G ALTERNATE ALUMINUM ANCHOR BOLT AND APPROXIMATELY AT AWNING BASE CABINET BASE PLATE BEAM BLOCK BOTH SIDES BOTH WAYS BOTTOM BRICK BUILDING CABINET CARPET CAST IRON CATCH BASIN CEILING CEMENT CENTER CERAMIC TILE CHALKBOARD CLEAN OUT CLOSET COLUMN COMBINATION CONCRETE CONSTRUCTION CONCRETE MASONRY UNIT CONTINUOUS CONTRACTOR CONTROL JOINT COUNTER TOP DEMOLITION DEPARTMENT DETAIL DIAMETER DIMENSION DOOR DOVETAIL ANCHOR DOVETAIL SLOT DOWN DRAWING DRINKING FOUNTAIN EACH EAST ELECTRICAL ELECTRICAL CONTRACTOR ELECTRIC HAND DRYER ELECTRIC WATER COOLER ELEVATION ENCLOSURE EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXPOSED EXTERIOR EXTERIOR GYPSUM CEILING BOARD F.O.S. FT. F.N.D. F.N.V. FIN. FIN. OPNG. F.E. F.E.C.R. F.H. F.R.P. F.R.T. FL F.D. F.P. FIG. F.M. GALV. GA. G.C. GL G.B. G.W.B. GYP. HC. HDW. HT. H. H.C. H.M. HORIZ. IN. INCL I.D. INSUL. JT. JST. LAM. LL. LAV. L MGR. M.H. MFR. MAS. M.O. MAT'L MAX. MECH. MT. M.F. M.S. M.R.D. MIN. M. MISC. M.R. M.B.H. MID. N. N.I.C. N.T.S. NO. FACE OF STUD FEET FEMININE NAPKIN DISPOSAL FEMININE NAPKIN VENDOR FINISH FINISH OPENING FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET RECESSED FIRE HYDRANT FIRE RETARDANT PANEL FIRE RETARDANT TREATED FLOOR FLOOR DRAIN FLUSH PANEL FOOTING FRAMED MIRROR GALVANIZED GAUGE GENERAL CONTRACTOR GLASS GRAB BAR GYPSUM WALLBOARD GYPSUM HANDICAPPED HARDWARE HEIGHT HIGH HOLLOW CORE HOLLOW METAL HORIZONTAL INCH INCLUDE INSIDE DIAMLIE.R INSULATION JOINT JOIST LAMINATED LANDLORD LAVATORY LONG MANAGER MANHOLE MANUFACTURER MASONRY MASONRY OPENING MATERIAL MAXIMUM MECHANICAL METAL METAL FRAME METAL STUD METAL ROOF DECK MINIMUM MIRROR MISCELLANEOUS MOISTURE RESISTANT MOP AND BROOM HOLDER MOUNTED NORTH NOT IN CONTRACT NOT TO SCALE NUMBER O.C. OPNG. OPP. HAND 0.D. PR. P.T.D. P.T.N. P.COL PLAS. P.LAM. PLUMB. P.C. PLYWD. P.T. PHONE Q.T. R. RECT. REINF. REQ'D. REV. R.D. RM. R.O. S.C.O.F. S.N.D. SCH. SNT. SECT. SHT. SHO. SHO.C. SHO.H. SIM. S.D. S.H. S.C. S. SPECS. 5Q. SQ.FT. S.S. STD. STL SIR. S.M.S. SUSP. SYS. TKBD. T.C. T.P.H. T.& G. T.B. TYP. U. U / S V.T.R. VERT. V.T. W.R. W.C. W.N. W.P. W. W/. w /0. WD. ON CENTER OPENING OPPOSITE HAND OUTSIDE DIAMETER PAIR PAPER TOWEL DISPENSER PAPER TOWEL HOLDER PIPE COLUMN PLASTER PLASTIC LAMINATE PLUMBING PLUMBING CONTRACTOR PLYWOOD PRESSURE TREATED TELEPHONE QUARRY TILE RADIUS RECTANGULAR REINFORCEMENT REQUIRED REVISION ROOF DRAIN ROOM ROUGH OPENING SUP COEFFICIENT OF FRICTION SANITARY NAPKIN DISPOSAL SCHEDULE SEALANT SECTION SHEET SHOWER SHOWER CONTROLS SHOWER HEAD SIMILAR SOAP DISPENSER SOAP HOLDER SOLID CORE SOUTH SPECIFICATIONS SQUARE SQUARE FEET STAINLESS STEEL STANDARD STEEL STRUCTURAL STRUCTURAL METAL STUD SUSPEND SYh1LM TACKBOARD TENANT CO- ORDINATOR TOILET PAPER HOLDER TONGUE AND GROOVE TOWEL BAR TYPICAL, UNLESS OTHERWISE NOTED URINAL UNDERSIDE VENT THROUGH ROOF VERTICAL VINYL TILE WASTE RECEPTACLE WATER CLOSET WATER HEATER WATER PROOF WEST WIDTH WITH WITHOUT WOOD DRAWING INDEX C -1 COVER SH EL I C -2 ROOM FINISH & RESPONSIBILITY SCHED., A -1 REFL. CLG. PLAN & FLOOR PLAN A -2 ELEVATIONS A -3 ELEVATIONS AD -1 AD -2 AS -1 K -1 K -2 E -2 P -1 P -2 By Date: DETAILS DETAILS ARCHITECTURE SPECIFICATIONS & NOTES EQUIPMENT PLAN, COUNTER CUT —OUT, ROUGH —IN PLANS/ LOCATIONS EQUIPMENT SCHEDULE H -1 HOOD DRAWINGS H -2 HOOD DRAWINGS H -3 HOOD DRAWINGS M -1 MECHANICAL PLAN & SCHEDULES E -1 POWER & LIGHTING PLANS ELECTRICALS DETAILS & PANEL SCHEDULES PLUMBING PLANS PLUMBING DETAILS r - FILE COPY Permit No. Plar review approval Is subject to errors and omissions. Approval of construction tents does not authorize the violation of any adopted code or 07' approved Field t .. . Re 1pt 7► City of Tukwila BUILDINS DIVISION ed: WALL LENGEND ELECTRICAL & PLUMBING REVISIONS No changes shall be made to the scritv of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submittal and may irk additional plan review fees. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical (Electrical Plumbing lE Gas Piping City of Tukwila BUILDING DIVISION SYVBOLS LEG - \ v oi d r SECTION CUT INDICATION PLAN DETAIL INDICATION ELEVATION INDICATION DOOR IDENTIFICATION FINISH INDICATOR EQUIPMENT SYMBOL FURNISHING & ACCESSORIES INDICATOR GENERAL NOTES ELEVATION TARGET D 0 L.L. SECTION NUMBER SHEET NUMBER DETAIL AREA DETAIL NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER NOTES WHICH APPLY TO SPECIFIC ITEMS DN DRAWINGS WHERE INDICATED. 3), NOTES WHICH APPLY TO ALL DRAWINGS. 0 -0 -0-- ELEVATION ABOVE FIN. FLR�� SURFACE DESCRIPTION CENTERLINE DIAMETER PLATE LEASE LINE JAN 16 2000 PEh jia .I L rt., COVER SHEET tiOBoiB ‹ <1 <J �J= CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS • o JOB NUMBER 21 SHEET NUMBER LLI z LEI 0 0 cn 0 J L�l cn LEI Cl O CO CC CO < 0 _ � 0 0 0 No cc) co DATE OF ORIGINAL ISSUE 24 SEPTME5ER 20e" d- E ' o r V c N +J] U N M N 1 s r (-4 0T e c N N C 2 X N. ' �� F- N IN. V ,n a8 x 0 .E 0 m c.n z O 2 oG w AIR SALANGE SCHEDULE (GEM) Ck4NCA I OUIFM OUTSIDE MAKE UPEXHAUST AIR I A 'oaf-1911\141d 1 UEI CI F S>} elb` W I R -G 15 300 -- DU MUA- -I -- R, M R SOk +35401 MARK N SOk DUJ NECK SIZE (DIAMETER) FACE SIZE (L' x 1U') FRAME TYPE NC REMARKS M DESCRIPTION MANUFACTURER NU R SPECIFICATIONS Rill-1 LAY -IN SURFACE NEW ROOF MOUNTED UNIT LENNOX LCA060I-12S S.T.U. CAPACITY, &0,000 / CFM,2000 / ESP , .50° / EER, 12.8/ MSI—I INPUT ,1S / OUTPUT ,>'02 /AFUE SO% / UNIT MOTOR DATA: VOLTS, 4S0, / PI—LASE, 3, / MCA., 16 / MOCF , 20 AMP'S / WE IC I—IT , 145 LSS. / 300 CFM 0S4 C 0 PER PLAN PER PLAN AIR SALANGE SCHEDULE (GEM) D I Lie OUTSIDE MAKE UPEXHAUST AIR AIR PRESSURE - R -G 15 300 -- DU MUA- -I -- R, RI R SOk +35401 MARK MANUFACTURER MODEL TYPE NECK SIZE (DIAMETER) FACE SIZE (L' x 1U') FRAME TYPE NC REMARKS A TITUS TMSA ADJUSTABLE SUPPLY DIFFUSER PER PLAN PER PLAN LAY -IN SURFACE 30 WHITE 13 TITUS 50F EGGCR4TE RETURN GRILLE PER PLAN PER PLAN LAY -IN 30 WHITE AIR SALANGE SCHEDULE (GEM) MK SUPPLY AIR RETURN AIR OUTSIDE MAKE UPEXHAUST AIR AIR PRESSURE R11J -I 2000 1600 300 -- +400 MUA- -I -- -- 4358 -- +35401 EF -I -- -- _- 322 -32201 EF -2 -- -- -- 1600 -1600 TOTAL. 2000 1600 4655 482 -111 M Ck4NC4I r N RA NC CONTRACTORS AND SUB CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS . INFORMATION REGARDING THE COMPLETE WORK IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCING THE COMPLETE DOCUMENT SET COORDINATE WITH THE WORK OF OTHER SECTIONS , EQUIPMENT FURNISHED SY OTHERS , REQUIREMENTS 01= THE OWNER AND CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE . PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION . NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK ALL ROOFING WORK (CUTS, REPAIRS, SPUD WORK, ETC.) SHALL BE PERFORMED BY THE LANDLORDS APPROVED ROOFING CONTRACTOR _ DRAWINGS FOR TI-IE MECHANICAL WORK ARE DIAGRAMMATIC SHOWING THE GENERAL LOCATION , EQUIPMENT TYPE AND LAYOUT , THE DRAWINGS SHALL NOT 15E SCALED FOR EXACT MEASUREMENT REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS . REFER TO MANUFACTURERS STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS . PROVIDE DUCTWORK , CONNECTIONS , OFFSETS , ACCESSORIES AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM . SUBMIT SHOP DRAWINGS PER THE SPECIFICATIONS . ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY INCLUDING APPLICABLE SECTIONS OF NFPA , OSHA , BOCA AND UBC OR ANY INTERIM AMENDMENTS AT THE TIME OF THE PROPOSAL _ PURCHASE ALL PERMITS ASSOCIATED WITH THE WORK AND OBTAIN ALL INSPECTIONS REQUIRED BY CODE _ CEILING FLEX DUCTMAX. 6' -0' FLEX DUCT SIZE SHALL MATCH NECK SIZE OPPOSED SLADE DAMPER DIFFUSER /DUCT CONNECTIONS SCALE: NO SCALE ROOF IN COUNTERFLASHIN CANT STRI r - 1 CEILING DIFFUSER COLLAR SUPPLY DUCT 0- ROOFTOP EQUIPMENT CURS DETAIL HAND DAMPER DRAW SAND WITH SILICONE SEALER ROOFTOP UNIT - SEE SPECS SPONGE RUBBER GASKET HEAVY -GAUGE STEEL CURB TO MATCH UNIT - SLOPE SASE OF CURS TO MATCH ROOF SLOPE INSULATION WOOD NAILER ADDITIONAL SUPPORT FOR EDGE OF ROOF DECK OR UNIT AS REQUIRED ADJACENT TENANT EQUIPMENT AREA MIN. 36' CLEAR AREA REQUIRED ON EACH SIDE (TYPICALY RTU 1 f Ar 2006 IMC 502.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508A MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4A. ILDIN DIV 12/12 ONE LAYER I -1/2" THICK FIREMASTER BLANKET FOR 1 HOUR FIRE RATING HOOD EXHAUST DUCT BANDING - 304 55 3/4 "W X .015" THICK MIN. 3" MIN. LONGITUDINAL OVERLAP AT BLANKET JOINT 3" MIN. PERIMETER OVERLAP AT BLANKET JOINT 1 -1/2" 10 -1/2" % 2I "TYP NOTE: WRAP GREASE DUCT CONTINUOUS AS SHOWN FOR ENTIRE LENGTH FROM KITCHEN HOOD GONNEGTION TO EXHAUST FAN ON ROOF. BANDING REQUIREMENTS: USE 304 STAINLESS STEEL FOR I HOUR RATING WRAP SUPPORT HANGER SYSTEM INDEPENDENTLY WITH SAME THICKNESS FOR EXTERNAL FIRE THREAT CONDITIONS. 02 ClREASE DUCT DETAIL SCALE: NO SCALE AIR I -I/2" 10 -1/2" ROOFTOP PACKA ED 1YAC UNIT DETAIL 03 SCALE: NO SCALE 14' -1' NOTES: ■ ALL DIMENSIONS MUST SE FIELD VERIFIED. R $ ALL EQUIPMENT CLEARANCES EQUIRED SY THE MANUFACTURER AND MODEL CODES MUST BE MAINTAINED. 0 EQUIPMENT AREA D IMENSION PLAN SCALE. 1/4° =1' -0' P[\] E G rico 01 5 0/5 -iGH r . 1r suPscoN i r1 /.n■muso110uu Sp:1RA1� PG,�E GOAp p �( pL A �� 0PPI, � G4N�G of TR ��� . �R I N�D GS p O TA T .DER y IMC 506.3.12 Exhaust outlets serving ( 1 1 P -Pi Type I hoods. IMC 506.3.12.1 Termination above the roof. Exhaust outlets that terminate above the roof shall have the discharge opening located not less than 40 inches above the roof surface. IMC 506.3.12.3 Termination location. Exhaust outlets shall be located not less than 10 feet horizontally from parts of the same or contiguous buildings, adjacent property lines and air intake openings into any building and shall be located not less than 10 feet above the adjoining grade level. I 1 1 1 1 1 1 1 1 I , 1 1 1 1 1 1 1 r 1 r LANDLORDS EQUIPMENT ENCLOSURE / MFCk4NC4 i NOT =5 E SN'Vf501_ r 10 11 12 13 14 NEW RTU W /GAS HEAT AND ASSOCIATED ROOF CURS TO BE PROVIDED AND INSTALLED BY THE TENANTS MECHANICAL CONTRACTOR IN LANDLORDS DESIGNATED ROOF MOUNTED EQUIPMENT AREA. ROUTE SUPPLY AND RETURN AIR DUCT BELOW ROOF TO TENANTS SPACE AS INDICATED. ALL ROUTING MUST BE VERIFIED IN FIELD. SEE EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION. PROVIDE DUCT MOUNTED SMOKE DETECTOR FOR AUTO FAN SHUT DOWN WHEN ACTIVATED. NEW EXHAUST FAN EF -I AND EF -2 AND ASSOCIATED CURS TO BE PROVIDED SY THE OWNER AND INSTALLED SY A THE MECHNAICAL CONTRACTOR IN LANDLORDS DESIGNATED ROOF MOUNTED EQUIPMENT AREA_ SEE DRWING SHEET M2.0 FOR ADDITIONAL INFORMATION. PROVIDE NEW 22/14 EXHAUST DUCT FROM HOOD TO NEW EF -1 ON ROOF. DUCT IS SIZED TO PROVIDE MIN_ 1500 FPM UPBLAST DISCHARGE VELOCITY. 22x14 =308 SQ/IN /144 =2.13 SQ. FT. - 3229 CFM /2.13= 1510 FPM_ CONTRACTOR SHALL ROUTE DUCT BELOW ROOF FROM FAN LOCATION TO TENANTS SPACE. INSTALL DUCT AT 1/4' PER FOOT FALL. PROVIDE ACCESS DOORS AT EACH CHANGE OF DIRECTION .SEE DUCT WRAP DETAIL ON THIS SHEET. PROVIDE NEW 12X12 EXHAUST DUCT FROM HOOD TO NEW EF -2 ON 1R0OF. DUCT IS SIZED TO PROVIDE MIN. 1600 FPM UPBLAST DISCHARGE VELOCITY_ 12x12 =144 SQ /IN /144 =1 5Q FT. - 1600 CFM /1= 1600 FPM. CONTRACTOR SHALL ROUTE DUCT BELOW ROOF FROM FAN LOCATION TO TENANTS SPACE. INSTALL DUCT AT 1/4' PER FOOT FALL. PROVIDE ACCESS DOORS AT EACH CHANGE OF DIRECTION .SEE DUCT WRAP DETAIL ON THIS SHEET.SEE DUCT WRAP DETAIL ON THIS SHEET. NEW TYPE 1 EXHAUST HOOD PROVIDED BY OWNER AND INSTALLED BY THE MECHANICAL CONTRACTOR SEE 1-1000 AND FAN DETAIL DRAWINGS 1-11 AND H2 FOR ADDITIONAL INFORMATION. 5°x24° SUPPLY -MAKE UP AIR RISER UP FROM HOOD PROVIDING 501 CFM _ MECHANICAL CONTRACTOR MUST PROVIDE GALVANIZED STEEL TRANSITION FROM SUPPLY RISER TO 14' ROUND TRANSITION AS INDICATED. EXTEND SUPPLY BRANCH UP TO SUPPLY AIR MAIN AS INDICATED. DO NOT USE FLEX DUCT. PROVIDE VOLUME CONTROL DAMPER AT CONNECTION OF EACH BRANCH TO SUPPLY AIR MAIN_ 4 °x10' SUPPLY -MAKE UP AIR RISER UP FROM 1400D PROVIDING 338 CFM _ MECHANICAL CONTRACTOR MUST PROVIDE GALVANIZED STEEL TRANSITION FROM SUPPLY RISER TO 10' ROUND TRANSITION AS INDICATED. EXTEND SUPPLY BRANCH UP TO SUPPLY AIR MAIN AS INDICATED. DO NOT USE FLEX DUCT_ PROVIDE VOLUME CONTROL DAMPER AT CONNECTION OF EACH BRANCH TO SUPPLY AIR MAIN. 4'x10' SUPPLY -MAKE UP AIR RISER UP FROM HOOD PROVIDING 262 CFM . MECHANICAL CONTRACTOR MUST PROVIDE GALVANIZED STEEL TRANSITION FROM SUPPLY RISER TO 10' ROUND TRANSITION AS INDICATED. EXTEND SUPPLY BRANCH UP TO SUPPLY AIR MAIN AS INDICATED. DO NOT USE FLEX DUCT_ PROVIDE VOLUME CONTROL DAMPER AT CONNECTION OF EACH BRANCH TO SUPPLY AIR MAIN. S SUPPLY -MAKE UP AIR RISER UP FROM HOOD PROVIDING 640 CFM . MECHANICAL CONTRACTOR MUST PROVIDE GALVANIZED STEEL TRANSITION FROM SUPPLY RISER TO 14° ROUND TRANSITION AS INDICATED. EXTEND SUPPLY BRANCH UP TO SUPPLY AIR MAIN AS INDICATED. DO NOT USE FLEX DUCT. PROVIDE VOLUME CONTROL DAMPER AT CONNECTION OF EACH BRANCH TO SUPPLY AIR MAIIKL 20'x20° SUPPLY AIR DROP FROM UNIT ABOVE. TRANSITION HORIZONTAL AS INDICATED.ROUTE DUCT BELOW ROOF FROM FAN TO TENANTS SPACE AS INDICATED. NEW MAKE UP AIR FAN/FURNACE MUA -1 AND ASSOCIATED CURB TO SE PROVIDED BY THE OWNER AND INSTALLED BY THE CONTRACTOR IN LANDLORDS DESIGNATED ROOF MOUNTED EQUIPMENT AREA. 5EE DRAWING SHEETS 141 AND H2 FOR ADDITIONAL INFOMATION. PROVIDE HONEYWELL T PROGRAMMABLE T'STAT WITH NIGHT SETBACK FEATURE AND LOCKING COVER . MOUNT AT 4S° AFF _ S'4D CONDITIONED SUPPLY AIR TO MAKE UP AIR PLENUM AT 1400D. 200 CFM. REVIEVVIJED FpR 1 1 1 1 ------- 01 MECHANICAL FLAN SCALE 1/4'=1'-0' APPROVED APR 1 7 2008 JAN 16 2008 P§ 1 1t Ee Eh M CHAN1CAL =LAN 4ND SCH' ITP 0 d N 00 CD M a 0 <KI<<<si CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS U JOB NUMBER 21 SHEET NUMBER QC w H- z w 0 H- D 0 U7 w IL H- U] w 1 . r ch Un CO CO N 0_ I CO CC CO LU 00 Cr) IUZ - 0 _ 0 O H- DATE OF ORIGINAL ISSUE 24 SMP'I`P'ISER 2001 E 0 U re x 0 0 PRELIMINARY DWGS. FOR L.L. APPROVAL LL COMMENTS