Loading...
HomeMy WebLinkAboutPermit M08-019 - WESTFIELD SOUTHCENTER MALL - TEAVANATEAVANA 856 SOUTHCENTER MALL M08 -019 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: TEAVANA Address: 856 SOUTHCENTER MALL , TUKWILA WA Owner: Name: Address: 856 SOUTHCENTER MALL TUKW Contact Person: Name: JAMES MOORE Address: 833 SE MAIN #242 , PORTLAND OR Contractor: Name: AIR MOTION INC Address: 5624 128 ST E , PUYALLUP WA Contractor License No: AIRMOI *077PM DESCRIPTION OF WORK: HVAC SYSTEMS FOR TENANT IMPROVEMENT OF NEW MALL SPACE Value of Mechanical: $15,000.00 Type of Fire Protection: CitAf Tukwila WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 1 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC-10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M08 -019 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 - 577 -8859 Phone: 253- 405 -6206 Expiration Date: 10/23/2009 M08 -019 06/13/2008 12/10/2008 Fees Collected: $327.20 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP/1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06-13 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -019 Issue Date: 06/13/2008 Permit Expires On: 12/10/2008 Date: c3 - 09 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not .. to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfv fiance • J • .am authorized to sign and obtain this mechanical permit. Signature: , _ �/ /� _ Date Print Name: (le '(---- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -019 Printed: 06-13 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Parcel No.: 6364200010 Address: 856 SOUTHCENTER MALL TUKW Suite No: Tenant: TEAVANA Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 019 Status: ISSUED Applied Date: 01/17/2008 Issue Date: 06/13/2008 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDMONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Cond -10/06 M08 -019 Printed: 06 -13 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. doc: Cond -10/06 * *continued on next page ** M08 -019 Printed: 06-13 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 M08 -019 Date: e /✓ ordinances governing or local laws regulating Printed: 06-13 -2008 JAN 17 2008 SITE LOCATION Site Address: c3t4 - 1C-A- - Tenant Name / Property Owners Name: Lt. Mailing Address: Company Name: Company Name: Mailing Address: CITY OF TUKWIL" Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us MECHANICAL PERMIT APPLICATION Mechanical Permit No. r' ■( Project No. 906'0 d 1 (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: (9, ) 0 — CI)O ( 0 Suite Number: Floor: New Tenan • • '.... Yes El ..No e-j CONTACT PERSON - who do we con Name\yY\ e r Y Mailing Address: f, 3 3 G. E -Mail Address: X. %'‘111C 5-D r e,( G Vr i'v C 1 A._ City v State Zip ct when your permit is ready to he issued Day Telephone:`] 0 ,5' 77 7 - '& Or_ ')72J3 City C _ State Zip Fax Number: D `. o f 2 3 0 MECHANICAL CONTRACTOR INFORMATION "Mb Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: Company Name: -1— 1r( f () (. � C Mailing Address: k"1 ( C6 0 e 3P)) (JO State Zip ARCHITECT OF RECORD -; All pl Lou r3 014 City Slate L� Z Contact Person: Day Telephone: 3 1 4a� 5 `2-40 l/ E -Mail Address: Fax Number: 'R I 7 4.IcS 1,30 ENGINEER OF RECORD — All pl m u be wet stamped by Engineer of Record Zip Contact Person: E -Mail Address: Q:\Applications\Forms- Applications On Linen -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh City Day Telephone: Fax Number: State Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM ` Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ rj °j Scope of Work (please provide detailed information): a Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ..Z Replacement .... ❑ Fuel Type: Electric Gas .... ❑ Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all, permits in s d'p- pllca' Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ( '_ UTHORIZED AGENT: Signatur Print Name: Mailing Address: Date Application Accepted: QAApplications\Fonns- Applications On Line \3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Date: I Vv a y Telephone: � 9" , z2._ City C (7 J State Zip Date Application Expires: 7 - L7_0 Staff Initials: Page 2 of 2 Receipt No.: R08 -00164 Payee: PRECISION PERMITSERVICE ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES RECEIVE D JAN 18 2008 OOMWIUNiTY DEVELOPMENT City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -019 Address: 856 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/17/2008 Applicant: TEAVANA Issue Date: Initials: WER Payment Date: 01/17/2008 02:10 PM User ID: 1655 Balance: $267.76 TRANSACTION LIST: Type Method Description Amount Payment Check 5386 59.44 Account Code Current Pmts 000/345.830 59.44 Total: $59.44 Payment Amount: $59.44 7377 01/17 9710 TOTAL 713.99 doc: Receipt -06 Printed: 01 -17 -2008 Project: 1 eQ.1/' � Type of Inspection: .A Address: `° Date Called: Special Instructions: Date Wanted: 74/4 f a.m. P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1)708'-0/ rzi Approved per applicable codes. Corrections required prior to approval. ❑ $60.0r EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Receipt No.: Date: Project: 7 "e ((A Type of Inspection: d <<6,,..-E of 1 o tw/ d• Address: $ 5 G VnAi L Date Called: Special Instructions: Date Wanted:... ■ ( I / l d a.m. p.m. Requester: Phone No: i # — C. 1 . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 'R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Ig Approved per applicable codes. COMMENTS: V A tJ -' 1 .c ��d r{S�s n yS I — Q15Se Date: .. d 7 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: 'Receipt No.: INSPECTION RECORD Retain a copy with permit Date: PERMIT NO. ` Corrections required prior to approval. Project: . "'"7 - E. c,..4 0- tea. Type of Ins ection: ..440)1.0e. ' ,.4&r;k Address: it 15C )\4 \\ Date Called: Special Instructions: Date Wanted: . a. m. .m. Requester: Phone No: . INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 114 PERMIT NO. • (206)431 -3670 COMMENTS: Approved per applicable codes. El $60.00 REINSPECTION FEE REQI)IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Corrections required prior to approval. Project: w { 4 _ Type gflnspectio ,� V Addr s: Date Called: Special Instructions: Date Wanted: �m - 7 - i 6 -Q p.m. 'Requester: Phone No: 7Go - 371`7 a INSPECTION RECORD Retain a copy with permit INSPECTION NO. 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: ❑ $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: (206)431 -3670 !d dam' Project: 0 VA- Type of Inspection: Address: "5 /1147/ Date Called: / Special Instructions: Date Wanted: O 4 --/6- e p.m. Requester: Phone o: INSPECTION NO. INSPECTION RECORD Retain a copy with permit En PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: %]/ Inspector: Date: $60. REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: _ - V �N Sprinklers: Hood & Duct: Type of Inspection: Hi fs c. se c' 6 L Address: c5--(.0 s • C . Suite #: iv+.l i_. Contact Person: 6r1L.� Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Hood & Duct: Fire Alarm: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER r Park East Tukwila, Wa. 98188 206- 575 -4407 Approved per applicable codes. COMMENTS: INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS Corrections required prior to approval. Inspector: pv, s , v Date: / , / r? 8 ■: e $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. CaII to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 06 -05 -2008 JAMES MOORE 833 SE MAIN #242 PORTLAND OR 97213 RE: Permit Application No. M08 -019 856 SOUTHCENTER MALL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 01/17/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 07/15/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 07/15/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, 4.42 xc: ifer Marshall it Technician Permit File No. M08 -019 City of Tukwila Jim Haggerton, Mayor 11 epartment of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Public Works Complete Comments: Please Route Documents/routing slip.doc 2 -28 -02 • PLAN DEPARTMENTS: Bui • i j g (vision n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) d TUES/THURS ROUTING: APPROVALS OR CORRECTIONS: 611 4iA - Fire Prevention Structural Incomplete Structural Review Required • ING SLIP ACTIVITY NUMBER: M08 -019 DATE: 01 -17 -08 PROJECT NAME: TEAVANA SITE ADDRESS: 856 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued n Planning Division n Permit Coordinator DUE DATE: 01 -24 -08 Not Applicable lip ►4 Permit Center Use Only - INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ❑ No further Review Required DUE DATE: 02 -21 -08 Approved ❑ Approved with Conditions d Not Approved (attach comments) U Notation: REVIEWER'S INITIALS: n REVIEWER'S INITIALS: DATE: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Receipt No.: R08 -02108 Payee: AIR MOTION ACCOUNT ITEM LIST: Description MECHANICAL - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 20193 257.76 Payment Cash 10.00 RECEIPT Account Code Current Pmts 000/322.100 267.76 Total: $267.76 Parcel No.: 6364200010 Permit Number: M08 -019 Address: 856 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/17/2008 Applicant: TEAVANA Issue Date: Payment Amount: $267.76 Initials: WER Payment Date: 06/13/2008 12:19 PM User ID: 1655 Balance: $0.00 3602 06/13 9710 TOTAL 267.76 doc: Receipt-06 Printed: 06 -13 -2008 License Information License AIRMOI *077PM Licensee Name AIR MOTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601495387 Ind. Ins. Account Id Business Type CORPORATION Address 1 5624 128TH ST E Address 2 City PUYALLUP County PIERCE State WA Zip 98373 Phone 2537708270 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 10/14/1993 Expiration Date 10/23/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date VERT, LYNN V 01/01/1980 DOWNS, WILLIAM R 01/01/1980 VERT, LYNN V AGENT 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information Savings Information Bank I Assignment Page 1 of 2 https:// fortress .wa.gov /lni/bbip /printer.aspx ?License= AIRMOI *077PM 06/13/2008 AIR DEVICE SCHEDULE 8 PLAN MARK , Q ' MODEL NO. MODULE SIZE FACE SIZE NECK SIZE FLEX SIZE T NOTES A 2 TMSA -1 /AG -75 24 "x24" 18 "x18" 10" RD. 10" RD. DIFF. 1,2,3 B 1 PAR 24 "x24" N/A 22 "x22" N/A R.G. 2 C 1 PAR 24 "x24" N/A 22 ° x22" N/A R.G. 4 D 1 PAR 24 "x24" 18 "x18" 12" RD. 12" RD. DIFF. 1,2,3 E 1 TMSA- 1/AG -75 24 "x24" 18 "x18" 8" RD. 8" RD. DIFF. 1,3,4 NOTES PLAN FOR THROW PATTERN FIT LAY —IN CEILING MODULE INSTALL MANUAL VOLUME DAMPER FIT GYP BOARD ROUGH IN, USE TRM FRAME FOR ACCESS PANEL 1. REFER TO 2. FRAME SHALL 3. PROVIDE & 4. FRAME SHALL VAV BOX SCHEDULE MANUFACTURER MODEL NO. MINIMUM AIR CFM TOTAL CFM INLET SIZE DISCHARGE SIZE BASE UNIT WEIGHT *TRANE VPFC12 200 925 12" 19 "x16" 85 LBS COOLING CAPACITY HEATING CAPACITY FAN SIZE FAN HP VOLTS PH HZ FLA ACCESSORIES: 1. SOUND ATTENUATOR 2. ELECTRONIC CONTROLS (COORDINATE WITH LANDLORD ON EXACT TYPE OF CONTROLS REQUIRED, PRIOR TO BID) 18,981 BTUH N/A 3SQ 1/3 115 1 60 5.5 LANDLORD'S SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. 1' —O" 115V WIRING & J —BOX BY ELECTRICAL CONTRACTOR J —BOX r' * THERMOSTAT WIRING — ' BY HVAC CONTRACTOR MEDIMUM PRESSURE DUCT ELECTRONIC DAMPER OPERATOR * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT A CONICAL OR CENTERLINE TAPER FITTING SHALL BE UTILIZED FOR THE PRIMARY DUCT TAP HANGERS (TYP. OF 4) VAV BOX VAV BOX CONNECTION DETAIL I SCALE NODE BEAM N CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' BEAM CLAMP PIPE HANGER DETAIL I SCALE MOPE HANGER SPACING AND ROD SIZE PIPE MAX ROD SIZE SPAN SIZE 1/2" 7' 3/8" 3'4 7' 3/8" 1 7' 3/8" 1 1/4" 7' 3/8" 1 1/2" 9' 3/8" 2" 10' 3/8" 2 1/2" 11' 1/2" 3 12' 1/2" " 3 1/2" 13' 1/2" 4" 14' 5/8" 5" 16' 5/8" 6" 17' 3/4" 8" 19' 3/4" 10" 22' 7/8" 12" 23' 7/8" 14" 25' 1 16" 27' 1" 18" 28' 1" 20" 30' 1 1/4" 24 32' 1 1/4" ROOF JOIST HANGER WIRE SHEET MTL. DUCT HANGER SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS ROUND DUCT HANGER DETAIL SCALE NONE ROOF JOIST HANGER WIRE SHEET MTL. DUCT HANGER DUCT HANGER DETAIL SCALE NONE RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS MECHANICAL SPECIIRCAT1ONS ORDINANCES. PERMITS. AND CERTIFICATES ALL WORK UNDER THIS DMSION OF THE SPECIFICATIONS SHALL BE INSTALLED IN FULL ACCOR— DANCE WITH ALL LAWS, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AUTHORITIES (LOCAL, STATE, AND FEDERAL) HAVING JURISDICTION WHICH IN ANY WAY WILL AFFECT THIS WORK. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND CERTIFICATES OF IN— SPECTION REQUIRED BY THE FOREGOING GOVERNMENTAL AUTHORITIES. ALL WORK SHALL BE IN— STALLED IN FULL ACCORDANCE WITH REGULATIONS OF THE UNDERWRITERS HAVING JURISDICTION. VISIT JOB SITE VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. GUARANTEE ALL LABOR AND MATERIAL FURNISHED UNDER THIS CONTRACT WILL. BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE TENANT. DURING THIS TIME, THIS CONTRACTOR SHALL REPAIR ALL LEAKS AND CORRECT ALL DISCREPANCIES WITH CODES OR THE SPECIFICATIONS AT HIS OWN EXPENSE DUCTWORK PRESSURE CLASS: 1" W.G. SEAL CLASS: B ALL NEW SUPPLY AIR DUCTS SHALL BE MADE OF GALVANIZED SHEET METAL WRAPPED WITH 2 OF INSULATION (UNLESS OTHERWISE NOTED). NEW DUCTWORK SHALL BE INSTALLED ACCORDING TO SMACNA AND ASHRAE CURRENT STANDARDS DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT /ENGINEER. ALL DUCTS WILL BE MADE AIRTIGHT WITH THE USE OF APPROVED DUCT JOINTS, CAULKING AND SHEET METAL SCREWS. ALL DUCT TAPE OR SIMILAR MATERIALS WILL BE REJECTED BY THE TENANT. NO GLASS FIBER OR SIMILAR MATERIALS WILL BE ACCEPTED AS A SUBSTITUTE FOR SHEET METAL DUCTWORK. FLEXIBLE INSULATED, ROUND DUCT WILL BE PERMITTED FOR F1NAL CONNECTIONS TO DIFFUSERS AND OUTLETS PROVIDED THAT IN NO CASE SHALL THIS FLEXIBLE DUCT EXCEED 5' —O" IN LENGTH. CONNECTIONS BETWEEN DIFFUSERS AND OUTLETS, AND BE— TWEEN FLEXIBLE DUCT AND SHEET METAL DUCTS, SHALL BE MADE WITH HOSE CLAMPS, OR COLLARS SECURED WITH SHEET METAL SCREWS. SHORT RADIUS BEND WILL BE MADE WITH ADJUSTABLE SHEET METAL ELBOWS. DO NOT ATTEMPT SHORT RADIUS BENDS USING FLEXIBLE DUCT. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC —PLUS— EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. INSULATION SUPPLY DUCTWORK CONCEALED ABOVE CEILING SHALL HAVE 2" FIBERGLASS "Owens—Corning" DUAL TEMP TYPE 100 WITH REINFORCED ALUMINUM FOIL FACING, APPLIED WITH ADHESIVE AND STRAPPED 8' -0" ON CENTERS WITH STICK CUPS. AIR DISTRIBUTION CEILING OUTLETS, REGISTER AND GRILLES SHALL BE MADE BY TITUS COMPANY OF SIZE AND TYPE SHOWN ON THE DRAWINGS AND ACCORDING TO THE AIR DEVICE SCHEDULE WITH BAKED WITH ENAMEL FINISH, UNLESS OTHERWISE NOTED. EACH OUTLET SHALL BE COMPLETE WITH INTEGRAL OPPOSED BLADE DAMPER. AIR BALANCE WHEN THE AIR DISTRIBUTION SYSTEM IS 100% COMPLETE ENTIRE SYSTEM MUST BE BALANCED TO THE AIR QUANTITIES AS INDICATED ON THE PLANS, IN ACCORDANCE WITH THE AABC OR NEBB SPECIFICATIONS. REPORTS MUST BE SUBMITTED (4) COPIES FOR EACH SYSTEM FOR APPROVAL TO THE TENANT AND ARCHITECT. COPY OF REPORT MUST ALSO BE SUBMITTED TO MALL LANDLORD. BALANCING COMPANY SHALL BE AN INDEPENDENT COMPANY AFFILIATED WITH THE AMERICAN AIR BALANCING COUNCIL. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD — DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. DRAWINGS THIS CONTRACTOR SHALL SUBMIT 4 COPIES OF RECORD DRAWINGS SHOWING EXACT LOCATIONS OF THE UNIT, DUCTS, DIFFUSERS, ETC., FOR FUTURE REFERENCE. UPON COMPLETION OF INSTALLATION, SUBMIT A CERTIFIED TEST AND BALANCE REPORT TO LANDLORD FOR REVIEW AND APPROVAL THE REPORT SHALL INCLUDE ALL AIR FLOW BALANCE DATA. MECHANICAL GENERAL NOTES PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT EXISTING CONDITIONS TO ENSURE THAT WORK REPRESENTED ON DRAWINGS CAN BE INSTALLED AS INDICATED. COORDINATE DISCREPANCIES BETWEEN DOCUMENTS AND FIELD CONDITIONS WITH THE TENANT OR HIS AUTHORIZED AGENT. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. ARRANGE WITH LOCAL AND STATE AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE CONNECTIONS FOR TEMPORARY AND PERMANENT WATER, SANITARY SEWER, STORM AND INDUSTRIAL WASTE SERVICES IF APPUCABLE, VERIFYING LOCATIONS AND ARRANGEMENT, AND PAY ALL CHARGES INCLUDING INSPECTIONS. DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO ENCOMPASS A SYSTEM THAT WILL NOT INTERFERE WITH THE STRUCTURAL AND ARCHITECTURAL DESIGN OF THE BUILDING. COORDINATE WORK TO AVOID INTERFERENCE BETWEEN PIPING, EQUIPMENT, ARCHITECTURAL, AND STRUCTURAL WORK. NO COMPONENTS MAY BE ABANDONED IN PLACE. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED AND DISPOSED OF. COORDINATE DISPOSAL OF ALL REMOVED EQUIPMENT WITH THE LANDLORD. PROVIDE THE ENTIRE OPERATING SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT FREE OF OBJECTIONABLE VIBRATION OR NOISES. REFER TO ASHRAE HANDBOOK FOR RECOMMENDED NOISE CRITERIA (NC) UNLESS OTHERWISE NOTED. STATICALLY AND DYNAMICALLY BALANCE ROTATING EQUIPMENT, AND MOUNT OR FASTEN SO VIBRATION I5 PRODUCED OR TRANSMITTED TO OR THROUGH THE BUILDING. IF OBJECTIONABLE NOISE OR VIBRATION IS PRODUCED OR TRANSMITTED TO OR THROUGHOUT THE BUILDING STRUCTURE BY EQUIPMENT, PIPING, DUCTS OR OTHER PARTS OF WORK, RECTIFY SUCH CONDITIONS AT NO ADDITIONAL COMPENSATION. PROVIDE ADDITIONAL BALANCING DEVICES REQUIRED FOR COMPLETE SYSTEM BALANCING INCLUDING BUT NOT LIMITED TO VOLUME DAMPERS, VALVES, AND SHEAVES OR PULLEYS AT FANS. VERIFY THE SIZE, LOCATION, AND CONDITION OF THE EXISTING PIPING BUILDING MANAGEMENT SYSTEM CONNECTION POINTS, AND OUTSIDE AIR CONNECTIONS. REPLACE EXISTING COMPONENTS IF THEY ARE INADEQUATE FOR THE NEW REQUIREMENTS. COORDINATE ACCESS TO LANDLORD'S EQUIPMENT (VAV BOXES, FIRE DAMPERS, VOLUME DAMPERS, ETC) WITH LANDLORD'S GENERAL CONTRACTOR /REPRESENTATIVE TENANT G.C. SHALL ENGAGE LANDLORD'S DESINATED SEPARATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCING REPORTED TO LANDLORD'S BUILDING ENGINEER. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) HVAC -I- SPRINKLER KEYED NOTES 0 0 EXISTING LANDLORD SUPPLY AIR MAIN WITH VOLUME DAMPER. ADJUST DUCTWORK AS REQUIRED FOR ACTUAL LOCATION OF LANDLORD'S SUPPLY AIR MAIN. COORDINATE WITH LANDLORD. ® NEW VAV BOX PROVIDED AND INSTALLED BY HVAC CONTRACTOR. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. PROVIDE ELECTRONIC CONTROLS AS REQUIRED PER LANDLORD. ®PROVIDE AND INSTALL THERMOSTAT WITH SUB —BASE AND LOCKING COVER. COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 48" A.F.F. TURN KEY OVER TO STORE MANAGER. ® FLEXIBLE DUCT, MAXIMUM LENGTH 5' -0 ". PROVIDE SMOOTH TRANSITIONS AND PROPER SUPPORTS PER S.MA.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR F1NAL RUNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. ® NEW FIRE EXTINGUISHER SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT TYPE, QUANTITY AND LOCATION WITH LANDLORD AND LOCAL FIRE MARSHALL. ® EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. ®7 PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED. (TYP.). COORDINATE EXACT LOCATION WITH NEW CEILING FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW LOW PRESSURE SUPPLY AIR DUCT WITH 2" THICK EXTERNAL INSULATION (MIN. R -5) SUPPLIED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED. DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® PROVIDE MANUAL VOLUME DAMPER AT ALL DIFFUSER CONNECTIONS (TYPICAL). g 6" CLEAR HEIGHT ABOVE DEMISING WALLS TO BE USED AS PASSAGE FOR RETURN AIR BACK TO MALL'S ROOFTOP UNIT.. MECHANICAL CONTRACTOR'S NOTES ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PRO— POSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. 2" WIDE MIN. DUCT STRAP 48" 0.C. MAX. FIRE DAMPER (LOCATION WHEN REQUIRED) VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) SPIN —IN FITTING WITH BALANCING DAMPER AND 45' EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' —O ". DIFFUSER CEILING HVAC DUCTWORK DETAIL I SCALE NONE METAL SUPPLY DUCT EXTERNALLY INSULATED LANDLORDS NOTES 1. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. 2. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON AND THE CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. 3. ALL SPRINKLER HEADS IN THE FORWARD SELUNG AREA ARE TO BE CONCEALED POP OFF COVER TYPE. 4. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. 5. TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FLOOR SINK, MOUNTED 3' —O" A.F.F.. INSTALL A 1" CORROSION RESISTANT SHUT —OFF VALVE. 6. TENANT SHALL INSTALL A VANE TYPE WATER FLOW DETECTOR IN THE MAIN SPRINKLER UNE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. FILE COPY Permlt No. Par review approval is subject to ORM and mss. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt isadmowledged: of approved Field By Date, /3-0 City of Tukwila BUILDING DIVISION No VJS;or$ than 5th 's I ma to the scope of work Mthout p€iot approval of Tukwila Building NOTE: Revisions will require a —.new n subitlal and may include additional plan review fees. * OR APPROVED EQUAL * OR APPROVED EQUAL MECHANICAL PLAN SCALE w • ra MO 0 q REVIEWED R. CODE COMPLIANCE APPROVED ty Of Tukwila SEPARATE PERMIT REQUIRED FOR: i Mechanical (Electrical rio umbi ng Piping City of Tukwila BUILDING DIVISION JAN 1 7 2008 x HVAC SYMBOLS LECEND SUPPLY AIR DIFFUSER REFRIGERANT DISCHARGE UNE REFRIGERANT SUCTION LINE OUTDOOR AIR RETURN AIR SUPPLY AIR TOILET EXHAUST Z --D— RETURN AIR GRILLE CONDENSATE DRAIN UNE MOTORIZED DAMPER SMOKE DETECTION DEVICE THERMOSTAT SMOKE DETECTOR R.A.G. DIFF. M.D. F.C. RETURN AIR GRILLE DIFFUSER MANUAL DAMPER FLEXIBLE CONNECTION AIR DEVICE TYPE AIR VOLUME IN CUBIC FEET /MINUTE (CFM) I R.D. R.S. O.A. S.A. S.A. T.E. M S O ® • LANDLORD'S SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. 1' —O" 115V WIRING & J —BOX BY ELECTRICAL CONTRACTOR J —BOX r' * THERMOSTAT WIRING — ' BY HVAC CONTRACTOR MEDIMUM PRESSURE DUCT ELECTRONIC DAMPER OPERATOR * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT A CONICAL OR CENTERLINE TAPER FITTING SHALL BE UTILIZED FOR THE PRIMARY DUCT TAP HANGERS (TYP. OF 4) VAV BOX VAV BOX CONNECTION DETAIL I SCALE NODE BEAM N CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' BEAM CLAMP PIPE HANGER DETAIL I SCALE MOPE HANGER SPACING AND ROD SIZE PIPE MAX ROD SIZE SPAN SIZE 1/2" 7' 3/8" 3'4 7' 3/8" 1 7' 3/8" 1 1/4" 7' 3/8" 1 1/2" 9' 3/8" 2" 10' 3/8" 2 1/2" 11' 1/2" 3 12' 1/2" " 3 1/2" 13' 1/2" 4" 14' 5/8" 5" 16' 5/8" 6" 17' 3/4" 8" 19' 3/4" 10" 22' 7/8" 12" 23' 7/8" 14" 25' 1 16" 27' 1" 18" 28' 1" 20" 30' 1 1/4" 24 32' 1 1/4" ROOF JOIST HANGER WIRE SHEET MTL. DUCT HANGER SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS ROUND DUCT HANGER DETAIL SCALE NONE ROOF JOIST HANGER WIRE SHEET MTL. DUCT HANGER DUCT HANGER DETAIL SCALE NONE RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS MECHANICAL SPECIIRCAT1ONS ORDINANCES. PERMITS. AND CERTIFICATES ALL WORK UNDER THIS DMSION OF THE SPECIFICATIONS SHALL BE INSTALLED IN FULL ACCOR— DANCE WITH ALL LAWS, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AUTHORITIES (LOCAL, STATE, AND FEDERAL) HAVING JURISDICTION WHICH IN ANY WAY WILL AFFECT THIS WORK. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND CERTIFICATES OF IN— SPECTION REQUIRED BY THE FOREGOING GOVERNMENTAL AUTHORITIES. ALL WORK SHALL BE IN— STALLED IN FULL ACCORDANCE WITH REGULATIONS OF THE UNDERWRITERS HAVING JURISDICTION. VISIT JOB SITE VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. GUARANTEE ALL LABOR AND MATERIAL FURNISHED UNDER THIS CONTRACT WILL. BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE TENANT. DURING THIS TIME, THIS CONTRACTOR SHALL REPAIR ALL LEAKS AND CORRECT ALL DISCREPANCIES WITH CODES OR THE SPECIFICATIONS AT HIS OWN EXPENSE DUCTWORK PRESSURE CLASS: 1" W.G. SEAL CLASS: B ALL NEW SUPPLY AIR DUCTS SHALL BE MADE OF GALVANIZED SHEET METAL WRAPPED WITH 2 OF INSULATION (UNLESS OTHERWISE NOTED). NEW DUCTWORK SHALL BE INSTALLED ACCORDING TO SMACNA AND ASHRAE CURRENT STANDARDS DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT /ENGINEER. ALL DUCTS WILL BE MADE AIRTIGHT WITH THE USE OF APPROVED DUCT JOINTS, CAULKING AND SHEET METAL SCREWS. ALL DUCT TAPE OR SIMILAR MATERIALS WILL BE REJECTED BY THE TENANT. NO GLASS FIBER OR SIMILAR MATERIALS WILL BE ACCEPTED AS A SUBSTITUTE FOR SHEET METAL DUCTWORK. FLEXIBLE INSULATED, ROUND DUCT WILL BE PERMITTED FOR F1NAL CONNECTIONS TO DIFFUSERS AND OUTLETS PROVIDED THAT IN NO CASE SHALL THIS FLEXIBLE DUCT EXCEED 5' —O" IN LENGTH. CONNECTIONS BETWEEN DIFFUSERS AND OUTLETS, AND BE— TWEEN FLEXIBLE DUCT AND SHEET METAL DUCTS, SHALL BE MADE WITH HOSE CLAMPS, OR COLLARS SECURED WITH SHEET METAL SCREWS. SHORT RADIUS BEND WILL BE MADE WITH ADJUSTABLE SHEET METAL ELBOWS. DO NOT ATTEMPT SHORT RADIUS BENDS USING FLEXIBLE DUCT. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 181B. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC —PLUS— EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. INSULATION SUPPLY DUCTWORK CONCEALED ABOVE CEILING SHALL HAVE 2" FIBERGLASS "Owens—Corning" DUAL TEMP TYPE 100 WITH REINFORCED ALUMINUM FOIL FACING, APPLIED WITH ADHESIVE AND STRAPPED 8' -0" ON CENTERS WITH STICK CUPS. AIR DISTRIBUTION CEILING OUTLETS, REGISTER AND GRILLES SHALL BE MADE BY TITUS COMPANY OF SIZE AND TYPE SHOWN ON THE DRAWINGS AND ACCORDING TO THE AIR DEVICE SCHEDULE WITH BAKED WITH ENAMEL FINISH, UNLESS OTHERWISE NOTED. EACH OUTLET SHALL BE COMPLETE WITH INTEGRAL OPPOSED BLADE DAMPER. AIR BALANCE WHEN THE AIR DISTRIBUTION SYSTEM IS 100% COMPLETE ENTIRE SYSTEM MUST BE BALANCED TO THE AIR QUANTITIES AS INDICATED ON THE PLANS, IN ACCORDANCE WITH THE AABC OR NEBB SPECIFICATIONS. REPORTS MUST BE SUBMITTED (4) COPIES FOR EACH SYSTEM FOR APPROVAL TO THE TENANT AND ARCHITECT. COPY OF REPORT MUST ALSO BE SUBMITTED TO MALL LANDLORD. BALANCING COMPANY SHALL BE AN INDEPENDENT COMPANY AFFILIATED WITH THE AMERICAN AIR BALANCING COUNCIL. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD — DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. DRAWINGS THIS CONTRACTOR SHALL SUBMIT 4 COPIES OF RECORD DRAWINGS SHOWING EXACT LOCATIONS OF THE UNIT, DUCTS, DIFFUSERS, ETC., FOR FUTURE REFERENCE. UPON COMPLETION OF INSTALLATION, SUBMIT A CERTIFIED TEST AND BALANCE REPORT TO LANDLORD FOR REVIEW AND APPROVAL THE REPORT SHALL INCLUDE ALL AIR FLOW BALANCE DATA. MECHANICAL GENERAL NOTES PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT EXISTING CONDITIONS TO ENSURE THAT WORK REPRESENTED ON DRAWINGS CAN BE INSTALLED AS INDICATED. COORDINATE DISCREPANCIES BETWEEN DOCUMENTS AND FIELD CONDITIONS WITH THE TENANT OR HIS AUTHORIZED AGENT. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. ARRANGE WITH LOCAL AND STATE AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE CONNECTIONS FOR TEMPORARY AND PERMANENT WATER, SANITARY SEWER, STORM AND INDUSTRIAL WASTE SERVICES IF APPUCABLE, VERIFYING LOCATIONS AND ARRANGEMENT, AND PAY ALL CHARGES INCLUDING INSPECTIONS. DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO ENCOMPASS A SYSTEM THAT WILL NOT INTERFERE WITH THE STRUCTURAL AND ARCHITECTURAL DESIGN OF THE BUILDING. COORDINATE WORK TO AVOID INTERFERENCE BETWEEN PIPING, EQUIPMENT, ARCHITECTURAL, AND STRUCTURAL WORK. NO COMPONENTS MAY BE ABANDONED IN PLACE. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED AND DISPOSED OF. COORDINATE DISPOSAL OF ALL REMOVED EQUIPMENT WITH THE LANDLORD. PROVIDE THE ENTIRE OPERATING SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT FREE OF OBJECTIONABLE VIBRATION OR NOISES. REFER TO ASHRAE HANDBOOK FOR RECOMMENDED NOISE CRITERIA (NC) UNLESS OTHERWISE NOTED. STATICALLY AND DYNAMICALLY BALANCE ROTATING EQUIPMENT, AND MOUNT OR FASTEN SO VIBRATION I5 PRODUCED OR TRANSMITTED TO OR THROUGH THE BUILDING. IF OBJECTIONABLE NOISE OR VIBRATION IS PRODUCED OR TRANSMITTED TO OR THROUGHOUT THE BUILDING STRUCTURE BY EQUIPMENT, PIPING, DUCTS OR OTHER PARTS OF WORK, RECTIFY SUCH CONDITIONS AT NO ADDITIONAL COMPENSATION. PROVIDE ADDITIONAL BALANCING DEVICES REQUIRED FOR COMPLETE SYSTEM BALANCING INCLUDING BUT NOT LIMITED TO VOLUME DAMPERS, VALVES, AND SHEAVES OR PULLEYS AT FANS. VERIFY THE SIZE, LOCATION, AND CONDITION OF THE EXISTING PIPING BUILDING MANAGEMENT SYSTEM CONNECTION POINTS, AND OUTSIDE AIR CONNECTIONS. REPLACE EXISTING COMPONENTS IF THEY ARE INADEQUATE FOR THE NEW REQUIREMENTS. COORDINATE ACCESS TO LANDLORD'S EQUIPMENT (VAV BOXES, FIRE DAMPERS, VOLUME DAMPERS, ETC) WITH LANDLORD'S GENERAL CONTRACTOR /REPRESENTATIVE TENANT G.C. SHALL ENGAGE LANDLORD'S DESINATED SEPARATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCING REPORTED TO LANDLORD'S BUILDING ENGINEER. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) HVAC -I- SPRINKLER KEYED NOTES 0 0 EXISTING LANDLORD SUPPLY AIR MAIN WITH VOLUME DAMPER. ADJUST DUCTWORK AS REQUIRED FOR ACTUAL LOCATION OF LANDLORD'S SUPPLY AIR MAIN. COORDINATE WITH LANDLORD. ® NEW VAV BOX PROVIDED AND INSTALLED BY HVAC CONTRACTOR. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. PROVIDE ELECTRONIC CONTROLS AS REQUIRED PER LANDLORD. ®PROVIDE AND INSTALL THERMOSTAT WITH SUB —BASE AND LOCKING COVER. COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 48" A.F.F. TURN KEY OVER TO STORE MANAGER. ® FLEXIBLE DUCT, MAXIMUM LENGTH 5' -0 ". PROVIDE SMOOTH TRANSITIONS AND PROPER SUPPORTS PER S.MA.C.N.A. (TYPICAL). USE FLEXIBLE DUCT FOR F1NAL RUNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZES. ® NEW FIRE EXTINGUISHER SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE EXACT TYPE, QUANTITY AND LOCATION WITH LANDLORD AND LOCAL FIRE MARSHALL. ® EXISTING SPRINKLER SYSTEM MAIN. FIELD VERIFY EXACT SIZE AND LOCATION. ®7 PROVIDE NEW OR RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED. (TYP.). COORDINATE EXACT LOCATION WITH NEW CEILING FIXTURES AND LIGHTS. MODIFY SUPPLY PIPING AS REQUIRED. ® NEW LOW PRESSURE SUPPLY AIR DUCT WITH 2" THICK EXTERNAL INSULATION (MIN. R -5) SUPPLIED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED. DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. HOLD ALL DUCTWORK AS HIGH AS POSSIBLE AND /OR PRACTICAL IN JOIST SPACE. ® PROVIDE MANUAL VOLUME DAMPER AT ALL DIFFUSER CONNECTIONS (TYPICAL). g 6" CLEAR HEIGHT ABOVE DEMISING WALLS TO BE USED AS PASSAGE FOR RETURN AIR BACK TO MALL'S ROOFTOP UNIT.. MECHANICAL CONTRACTOR'S NOTES ALL OF THE MECHANICAL & SPRINKLER WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT. THE SUBMISSION OF THE PRO— POSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. 2" WIDE MIN. DUCT STRAP 48" 0.C. MAX. FIRE DAMPER (LOCATION WHEN REQUIRED) VOLUME DAMPER (FOR FINAL BALANCE ADJUSTMENT) SPIN —IN FITTING WITH BALANCING DAMPER AND 45' EXTRACTOR (DAMPER USED FOR ROUGH BALANCING) RIGID ROUND METAL DUCT EXTERNALLY INSULATED RIGID ROUND DUCT ELBOW EXTERNALLY INSULATED INSULATED FLEXIBLE DUCT MAX. LENGTH 5' —O ". DIFFUSER CEILING HVAC DUCTWORK DETAIL I SCALE NONE METAL SUPPLY DUCT EXTERNALLY INSULATED LANDLORDS NOTES 1. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WITH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE. LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. 2. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S SPRINKLER SYSTEM WITHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTALL ALL BRANCH PIPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE TENANT SPACE. TENANT'S SPRINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON AND THE CITY OF TUKWILA FIRE DEPARTMENT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH THE BASE BUILDING ACCORDING TO ORDINARY HAZARD GROUP 2 AND THE LATEST REQUIREMENTS OF NFPA -13. 3. ALL SPRINKLER HEADS IN THE FORWARD SELUNG AREA ARE TO BE CONCEALED POP OFF COVER TYPE. 4. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. 5. TENANT'S CONTRACTOR SHALL INSTALL AN INSPECTORS TEST CONNECTION, PIPED TO A FLOOR SINK, MOUNTED 3' —O" A.F.F.. INSTALL A 1" CORROSION RESISTANT SHUT —OFF VALVE. 6. TENANT SHALL INSTALL A VANE TYPE WATER FLOW DETECTOR IN THE MAIN SPRINKLER UNE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAIN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. FILE COPY Permlt No. Par review approval is subject to ORM and mss. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt isadmowledged: of approved Field By Date, /3-0 City of Tukwila BUILDING DIVISION No VJS;or$ than 5th 's I ma to the scope of work Mthout p€iot approval of Tukwila Building NOTE: Revisions will require a —.new n subitlal and may include additional plan review fees. * OR APPROVED EQUAL * OR APPROVED EQUAL MECHANICAL PLAN SCALE w • ra MO 0 q REVIEWED R. CODE COMPLIANCE APPROVED ty Of Tukwila SEPARATE PERMIT REQUIRED FOR: i Mechanical (Electrical rio umbi ng Piping City of Tukwila BUILDING DIVISION JAN 1 7 2008 x v l I LANDLORD'S SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. 1' -0" 115V WIRING & J —BOX BY ELECTRICAL CONTRACTOR J —BOX r i * THERMOSTAT WIRING -� BY HVAC CONTRACTOR MEDIMUM PRESSURE DUCT ELECTRONIC DAMPER OPERATOR * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT A CONICAL OR CENTERLINE TAPER FITTING SHALL BE UTILIZED FOR THE PRIMARY DUCT TAP HANGERS (TYP. OF 4) VAV BOX VAV BOX CONNECTION DETAIL I SCALE: NONE bE COMPLIANCE CLEVIS HANGER OVERSIZED FOR INSULATION WITH 18" ROLLED SLEEVE FOR SUPPORT 180' HANGER SPACING AND PIPE SIZE 1/2" 3/4" 1 1 1/4" 1 1/2" 2 2 1/2" 3 3 1/2" 4" 5" 6" 8 " 10" 12" 14" 16" 18" 20" 24 MAX SPAN 7' 7' 7' 7' 9' 10' 11' 12' 13' 14' 16' 17' 19' 22' 23' 25' 27' 28' 30' 32' ROD SIZE ROD SIZE 3 /8" 3/8" 3/8" 1/2" 1/2" 1/2" 5/8" 5/8" 3/4" 3/4" 7/8" 1 ' 1 " 1 " 1 1 /4 1 1 /4 PIPE HANGER DETAIL I SCALE NONE 3 ROOF JOIST HANGER WIRE Lit/ Of T UkW €l SPIRAL DUCT FED f SHEET MTL DUCT HANGER EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS ROUND DUCT HANGER DETAIL SCALE: aoE )/ lipp„ ROOF JOIST HANGER WIRE SHEET MTL DUCT HANGER DUCT HANGER DETAIL SCALE NONE RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS MECHANICAL SPECIFICATIONS ORDINANCES. PERMITS. AND CERTIFICATES ALL WORK UNDER THIS DIVISION OF THE SPECIFICATIONS SHALL BE INSTALLED IN FULL ACCOR— DANCE WITH ALL LAWS, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AUTHORITIES (LOCAL, STATE, AND FEDERAL) HAVING JURISDICTION WHICH IN ANY WAY WILL AFFECT THIS WORK. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND CERTIFICATES OF IN— SPECTION REQUIRED BY THE FOREGOING GOVERNMENTAL AUTHORITIES. ALL WORK SHALL BE IN— STALLED IN FULL ACCORDANCE WITH REGULATIONS OF THE UNDERWRITERS HAVING JURISDICTION. VISIT JOB SITE VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND /OR FAILURE TO PREDETERMINE ALL CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. GUARANTEE ALL LABOR AND MATERIAL FURNISHED UNDER THIS CONTRACT WILL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE TENANT. DURING THIS TIME, THIS CONTRACTOR SHALL REPAIR ALL LEAKS AND CORRECT ALL DISCREPANCIES WITH CODES OR THE SPECIFICATIONS AT HIS OWN EXPENSE DUCTWORK PRESSURE CLASS: 1" W.G. SEAL CLASS: B ALL NEW SUPPLY AIR DUCTS SHALL BE MADE OF GALVANIZED SHEET METAL WRAPPED WITH 2" OF INSULATION (UNLESS OTHERWISE NOTED). NEW DUCTWORK SHALL BE INSTALLED ACCORDING TO SMACNA AND ASHRAE CURRENT STANDARDS DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF ARCHITECT /ENGINEER. ALL DUCTS WILL BE MADE AIRTIGHT WITH THE USE OF APPROVED DUCT JOINTS, CAULKING AND SHEET METAL SCREWS. ALL DUCT TAPE OR SIMILAR MATERIALS WILL BE REJECTED BY THE TENANT. NO GLASS FIBER OR SIMILAR MATERIALS WILL BE ACCEPTED AS A SUBSTITUTE FOR SHEET METAL DUCTWORK. FLEXIBLE INSULATED, ROUND DUCT WILL BE PERMITTED FOR FINAL CONNECTIONS TO DIFFUSERS AND OUTLETS PROVIDED THAT IN NO CASE SHALL THIS FLEXIBLE DUCT EXCEED 5' -0" IN LENGTH. CONNECTIONS BETWEEN DIFFUSERS AND OUTLETS, AND BE— TWEEN FLEXIBLE DUCT AND SHEET METAL DUCTS, SHALL BE MADE WITH HOSE CLAMPS, OR COLLARS SECURED WITH SHEET METAL SCREWS. SHORT RADIUS BEND WILL BE MADE WITH ADJUSTABLE SHEET METAL ELBOWS. DO NOT ATTEMPT SHORT RADIUS BENDS USING FLEXIBLE DUCT. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, GASKETS, OR MASTICS; MESH AND MASTIC SEAUNG SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A OR UL 1816. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURES LESS THAN OR EQUAL TO 2 W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), MASTIC— PLUS — EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT. INSULATION SUPPLY DUCTWORK CONCEALED ABOVE CEILING SHALL HAVE 2" FIBERGLASS "Owens— Corning" DUAL TEMP TYPE 100 WITH REINFORCED ALUMINUM FOIL FACING, APPLIED WITH ADHESIVE AND STRAPPED 8' —O" ON CENTERS WITH STICK CUPS. AIR DISTRIBUTION CEILING OUTLETS, REGISTER AND GRILLES SHALL BE MADE BY TITUS COMPANY OF SIZE AND TYPE SHOWN ON THE DRAWINGS AND ACCORDING TO THE AIR DEVICE SCHEDULE WITH BAKED WITH ENAMEL FINISH, UNLESS OTHERWISE NOTED. EACH OUTLET SHALL BE COMPLETE WITH INTEGRAL OPPOSED BLADE DAMPER. AIR BALANCE WHEN THE AIR DISTRIBUTION SYSTEM I5 100% COMPLETE ENTIRE SYSTEM MUST BE BALANCED TO THE AIR QUANTITIES AS INDICATED ON THE PLANS, IN ACCORDANCE WITH THE AABC OR NEBB SPECIFICATIONS. REPORTS MUST BE SUBMITTED (4) COPIES FOR EACH SYSTEM FOR APPROVAL TO THE TENANT AND ARCHITECT. COPY OF REPORT MUST ALSO BE SUBMITTED TO MALL LANDLORD. BALANCING COMPANY SHALL BE AN INDEPENDENT COMPANY AFFILIATED WITH THE AMERICAN AIR BALANCING COUNCIL TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWINGS AND SHALL RECORD VOLUME READINGS IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD — DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. DRAWINGS THIS CONTRACTOR SHALL SUBMIT 4 COPIES OF RECORD DRAWINGS SHOWING EXACT LOCATIONS OF THE UNIT, DUCTS, DIFFUSERS, ETC., FOR FUTURE REFERENCE. UPON COMPLETION OF INSTALLATION, SUBMIT A CERTIFIED TEST AND BALANCE REPORT TO LANDLORD FOR REVIEW AND APPROVAL THE REPORT SHALL INCLUDE ALL AIR FLOW BALANCE DATA. MECHANICAL GENERAL NOTES PRIOR TO SUBMITTING A PROPOSAL, THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY INSPECT EXISTING CONDITIONS TO ENSURE THAT WORK REPRESENTED ON DRAWINGS CAN BE INSTALLED AS INDICATED. COORDINATE DISCREPANCIES BETWEEN DOCUMENTS AND FIELD CONDITIONS WITH THE TENANT OR HIS AUTHORIZED AGENT. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. ARRANGE WITH LOCAL AND STATE AUTHORITIES AND UTILITY COMPANIES FOR PERMITS, FEES, AND SERVICE CONNECTIONS FOR TEMPORARY AND PERMANENT WATER, SANITARY SEWER, STORM AND INDUSTRIAL WASTE SERVICES IF APPLICABLE, VERIFYING LOCATIONS AND ARRANGEMENT, AND PAY ALL CHARGES INCLUDING INSPECTIONS. DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO ENCOMPASS A SYSTEM THAT WILL NOT INTERFERE WITH THE STRUCTURAL AND ARCHITECTURAL DESIGN OF THE BUILDING. COORDINATE WORK TO AVOID INTERFERENCE BETWEEN PIPING, EQUIPMENT, ARCHITECTURAL, AND STRUCTURAL WORK. NO COMPONENTS MAY BE ABANDONED IN PLACE. ALL COMPONENTS THAT ARE NOT REUSED MUST BE REMOVED AND DISPOSED OF. COORDINATE DISPOSAL OF ALL REMOVED EQUIPMENT WITH THE LANDLORD. PROVIDE THE ENTIRE OPERATING SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT FREE OF OBJECTIONABLE VIBRATION OR NOISES. REFER TO ASHRAE HANDBOOK FOR RECOMMENDED NOISE CRITERIA (NC) UNLESS OTHERWISE NOTED. STATICALLY AND DYNAMICALLY BALANCE ROTATING EQUIPMENT, AND MOUNT OR FASTEN SO VIBRATION IS PRODUCED OR TRANSMITTED TO OR THROUGH THE BUILDING. IF OBJECTIONABLE NOISE OR VIBRATION IS PRODUCED OR TRANSMITTED TO OR THROUGHOUT THE BUILDING STRUCTURE BY EQUIPMENT, PIPING, DUCTS OR OTHER PARTS OF WORK, RECTIFY SUCH CONDITIONS AT NO ADDITIONAL COMPENSATION. PROVIDE ADDITIONAL BALANCING DEVICES REQUIRED FOR COMPLETE SYSTEM BALANCING INCLUDING BUT NOT LIMITED TO VOLUME DAMPERS, VALVES, AND SHEAVES OR PULLEYS AT FANS. VERIFY THE SIZE, LOCATION, AND CONDITION OF THE EXISTING PIPING BUILDING MANAGEMENT SYSTEM CONNECTION POINTS, AND OUTSIDE AIR CONNECTIONS. REPLACE EXISTING COMPONENTS IF THEY ARE INADEQUATE FOR THE NEW REQUIREMENTS. COORDINATE ACCESS TO LANDLORD'S EQUIPMENT (VAV BOXES, FIRE DAMPERS, VOLUME DAMPERS, ETC) WITH LANDLORD'S GENERAL CONTRACTOR /REPRESENTATIVE TENANT G.C. SHALL ENGAGE LANDLORD'S DESINATED SEPARATE TEMPERATURE CONTROL CONTRACTOR FOR FINAL SET —UP OF SYSTEM(S) OPERATIONS AND AIR BALANCING. GIVE ONE COPY OF BALANCING REPORTED TO LANDLORD'S BUILDING ENGINEER. _ F _ JAN 1 7 2008 pE imi F, uLNTER