Loading...
HomeMy WebLinkAboutPermit M08-020 - HERZOG GLASSHERZOG GLASS 4344 S 104 PL M08-020 Parcel No.: 0323049026 Address: Suite No: 4344 S 104 PL TUKW Tenant: Name: HERZOG GLASS Address: 4344 S 104 PL , TUKWILA WA Owner: Name: SEBCO INC Address: 4020 E MADISON #320 , SEATTLE WA Contact Person: Name: KELVIN BATTLE Address: 25500 74 AV S , KENT WA Contractor: Name: PERFORMANCE HEATING Address: 7649 S 180 ST , KENT WA Contractor License No: PERFOHA15ORT DESCRIPTION OF WORK: REPLACE (2) FAILING ROOFTOP UNITS WITH (2) NEW UNITS IN SAME LOCATIONS. INSTALL (2) NEW THERMOSTATS TO REPLACE EXISTING. Value of Mechanical: $19,981.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 2 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: M08 -020 Issue Date: 02/01/2008 Permit Expires On: 07/30/2008 Phone: Phone: 425 251 -0356 Phone: 425 251 -0356 Expiration Date: 04/30/2009 Fees Collected: $384.83 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 2 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -020 Printed: 02 -01 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Permit Number: M08 -020 Issue Date: 02/01/2008 Permit Expires On: 07/30/2008 Date: 1 6 --o v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: �� /��� Date: fN Print Name: /S / •- 172/e This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -020 Printed: 02 -01 -2008 Parcel No.: 0323049026 Address: 4344 S 104 PL TUICW Suite No: Tenant: HERZOG GLASS 1: ** *BUILDING DEPARTMENT CONDPITONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS * *continued on next page ** Permit Number: M08 -020 Status: ISSUED Applied Date: 01/28/2008 Issue Date: 02/01/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M08 -020 Printed: 02 -01 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: -/ - ‘4 Print Name: /1/ / / / doc: Cond -10/06 Date: 2 / //k M08 -020 Printed: 02 -01 -2008 CITY OF TUKWILS Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.ttikwila.wa.m SITE LOCATION S Site Address: 4344(104th PL Seattle, Wa 98112 Tenant Name: Property Owners Name: Sebco, Washington Mutual Mailing Address: 4020 E. Madison Suite 320 Name: Kelvin Battle Mailing Address:25500 74th Ave S E -Mail Address: kelvins perfonnanceheating.com Company Name: Performance Heating & Air Conditioning Mailing Address: 25500 74th Ave S Contact Person: Kelvin Battle E -Mail Address: kelvin performanceheatinig.com Contractor Registration Number: PERFOHA15ORT Company Name: Mailing Address: Contact Person: E -Mail Address: y� Company Name: BCE Engineers, Inc Herzog Glass Mailing Address:17924 140th Ave NE, Suite 220 Contact Person: Eric A. Dann E -Mail Address: er i � dc.,.n n t3 64Icic . ►fie. t' Q.v pplications \Forms- Applicntions On Line\ -2006 - permit Application.doc Revised: 9 -2006 6h Building Pere No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** O 20 King Co Assessor's Tax No.:0323049026 Suite Number: bldg "A" Floor: l st New Tenant: Yes ❑ .. No Seattle City Day Telephone: Kent, City Fax Number:253- 867 -5775 Wa State 425 -251 -0356 WA State Fax Number: 253- 867 -5775 Expiration Date: 4/30/09 State Woodinville Wa 98072 -4315 City State Day Telephone: 425 -814 -8448 Fax Number: 42 —52 2)7- 98112 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued 98032 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Kent, WA City State Day Telephone: 425- 251 -0356 98032 Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace> I00K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 1 i 15 -30 HP /1,000,000 BTU Suspended /Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM 1 . / Incinerator — Comm/Ind MECHANICAL PERMIT INIMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: Performance Heating and Air Conditioning Mailing Address: 25500 74th Ave S Kent City Contact Person: Kelvin Battle Day Telephone: 425- 2581 -0356 E -Mail Address: kelvin(a,performanceheating.com Fax Number: 253- 867 -5775 Contractor Registration Number:PERFOHAI5ORT Expiration Date: 4/30/09 Valuation of Mechanical work (contractor's bid price): $ 19,981.00 Scope of Work (please provide detailed information): Replace (2) failing roof top units with (2) new units in same locations. Install (2) new thermostats to replace existing. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... [� Fuel Type: Electric.... Gas....[ Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Forms- Applications On Line U-2006 - Permit Application.doc Revised: 9 -2006 bh WA 98032 State Zip Page 4 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Print Name: Kelvin Battle Mailing Address: 25500 74th Ave S Date Application Accepted: • • Q:'Applications\Forms- Applications On Line V-2006 - Permit Application.doc Revised 9 -2006 bit Date Application Expires: cri-frbfr Date: //Z, 201 Day Telephone: 425- 251 -0356 Kent WA 98032 City State Zip Staff Initials: d ,_ Page 6 of 6 Parcel No.: 0323049026 Address: 4344 S 104 PL TUKW Suite No: Applicant: HERZOG GLASS Receipt No.: R08 -00237 ACCOUNT ITEM LIST: Description don! Rar.aint -OR PLAN CHECK - NONRES • • !l City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us ]RECEIPT Initials: =JEM Payment Date: 01/28/2008 10:54 AM User ID: 1165 Balance: $313.86 Payee: PERFORMANCE HEATING & AIR CONDITIONING, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 50980 70.97 Account Code Current Pmts 000/345.830 70.97 Total: $70.97 Permit Number: M08 - 020 Status: PENDING Applied Date: 01/28/2008 Issue Date: Payment Amount: $70.97 7726 01/28 9710 TOTAL 70.97 Printed fN- 9R -2f1OR Parcel No.: 0323049026 Address: 4344 S 104 PL TUKW Suite No: Applicant: HERZOG GLASS Receipt No.: R08 -00277 Initials: WER User ID: 1655 ACCOUNT ITEM LIST: City of Tukwila Payee: PERFORMANCE HEATING & A/C Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT TRANSACTION LIST: Type Method Description Amount Payment Check 50991 313.86 Description Account Code Current Pmts MECHANICAL - NONRES 000/322.100 313.86 Total: $313.86 Permit Number: M08 -020 Status: APPROVED Applied Date: 01/28/2008 Issue Date: Payment Amount: $313.86 Payment Date: 02/01/2008 10:37 AM Balance: $0.00 7932 02/01 9710 TOTAL 313.86 doc: Receiot -06 Printed: 02 -01 -2008 Projgct: item o / NV/ Type of Inspection: S�t.n K-( Sd■ � - t) (.4 Address: J J nl 1341 co viii /V1 t"L Date Called: Special Instructions: 0 i r7 . g 2d -D� �d P M sLA / e ve Ate My S / t � Date Wanted: 1 2r i - o(Y a.m. Requester: Phone � l (O �/ - &Z. 6.3 # z ItJSPECTION NO. INSPECTION RECORD Retain a copy with permit 11)14 -vet PERMIT NO. CITY OF TUKWILA BUILDING'DIVISION 6300 Southcenter,Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. /0 COMMENTS: /A Y s / u T daze/ 4 GOsi'.a2474 O4 . Inspector: Date: 5/7/ ❑ $586 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: COMMENTS: . N'Pi 5h -e e c ' S L k -- j .---1?L.S '\ — t ;t .-e e 41 t�J n t }- 1..1 ( c .4itirke. ft: a/ t\3 ik4 (Z■t--V t 1 R il_ ∎ t 63 A . Project' // �!' /,'A 6�� S Type of Inspection: / C%/V9 / Addrgssi _ /V / L � ® � Date Called: Special Instructions: Date W'an�� 7 /aE -�-.- a.m J Requester: ∎ P ' v, � 766 4 2 63 L t 41.0-620 INSPECTION RECORD Retain a copy with permit I NSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION *' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 111 Approved per applicable codes. Corrections required prior to approval. Insp ti ' � El $58.00 REINSPECTION FE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date Z ` - Receipt No.: 'Date: COMMENTS: Type of Inspection: s - r. ' ( )er (.a -- S a e 0 J( (A) 17+'4' c. r ; S re- 5 1 . ,-- Jam- Y w f Q - (i r Ni O o f P u S r Ls J A v/ rd L , _ Project: Project. C/ASS Type of Inspection: s - r. ' Addre 41 s a - 1 ci rn J G• Date Called: Special Instr ctions: 1 r - - t/ circ v P W Date Wanted: // ,, a . Requester: Phone No: .-5 -- IM — (3 C40 ' 2,-.C" - Mo - (92d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION re' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. El Corrections required prior to approval. Inspect: 1/4_,A A l a Date: ,5 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: r • ENGINEERING FILE C PY ern* P4o. Structural Calculations for Herzog Glass Support of Proposed HVAC Unit January 16, 2008 I EXPIRES 09.23.08 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 REv1E 'y': F z CODE COMPLIANCE PPRCVED JAN 2 P Ti C9y C. Tu';.•; _ • l `- ' I j RECEIVED CITY OF TUK\AI L JAN 2 a 223 PERMIT CENTER frJWI oZo 17 I ENGINEERING 17924 — 140Th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Calculations 137FL ENGINEERING 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Gravity Support OOM x31 GLI3 OFFICE 1 I }EXISTING 6 SLEEPERS. JI___ __IL ROOF STRUCTURAL PLAN EXISTING 4)(6 SLEEPERS. q 1/4 x q 1/4 GOLUMS TYP. 01 TL ENGINEERING C#?,cg /CM- z o i V./ floCLP fit/ 5 7.94 3 1.1 Cp /./S 2 )(4 IZTbf -z --- a . C 3 1( — Fr 7 M-f7 0,73 K-FT /6 / 7645 0 -4- eigt," 11- Project: 11 E/2 7 0 6- 6-14 55 MiicH Gmier IC? 1 1 7. 7 7/ I Project Number: 41-- i? - 67 " Client Scale: 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: 425-814-8448 Pax: 425-821-2120 ( 1 ... , 7 K-/ 6,6 Pt 4 7 S' Designed By Date. -.2 Page. TL ENGINEERING 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4315 Phone: 425-814-8448 Fax: 425-821-2120 PU//6 //i/ CHt/"C,r 44 4. = - 41-1, 4 ,0 1S-PT F b = /fad l s!. S = 135:66 ,y - 35 -. 0 11 " abo / 9- S K - pr u 7 44- S/zr D Z is CO X 0 ' 4 ec cisV 15 Fo/{ size,v4 x/444 Project: P 5./e 70 61 / 14 L.IK/rr Designed By: Date. Project Number. d r{ f— O 2 Client Scale: Page. G 3 TR ENGINEERING 17924 — 140th Avenue NE, Suite 220 Woodinville, WA 98072 -4M5 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Seismic Support Herzog Glass Mechanical Unit Revision Date: 1/16/2008 08- 199 -02 Occupancy Category: 11- Other Structures Seismic Use Group: I IE = 1.00 (Seismic Factor) I s = 1.00 (Snow Factor) I,,, = 1.00 (Wind Factor) Site Class: S s = 1.5 S = 0.52 D F a = 1.00 F,, = 1.50 Design Spectral Response Acceleration: S = F = 1.50 SOS = % SMS = 1.00 vs IBC Table 1604.5 ASCE Table 9.4.1.2 ASCE Table 9.4.1.2.4a ASCE Table 9.4.1.2.4b SM1 = F„S = 0.78 Sol = 2/ SM7 = 0.52 Herzog Glass Mechanical Unit Revision Date: 1/16/2008 08- 199 -02 Seismic Forces Component Operating Weight: 612 Ibs F = 0.4 a P SDS WP [ + (z/h)] R I F = 294 Ibs F p need not exceed: F = 1.6 Spsl p W p F = 979 Ibs F shall not be less than: F = 0.3 Sips 1p Wp F = 184 Ibs Dimensions: x = 5325 in y = 88.58 in z= 41 in Curb Height = : 5.25 •' in Check Uplift: Mor = 7564 lb-in MRESIsr = 14665 lb-in z Curb Height F.S. = 1.9 ASCE Eq. 9.6.1.3 -1 ASCE Eq. 9.6.1.3 -2 ASCE Eq. 9.6.1.3 -3 F p W 1 1.5 O.K. ENGINEERING Cs" GA GE 9 46-iri A;, 4 X/6./ W/ /0 - Cret - I AJ5 eol 16 5 Cieed Shle/1 cmr m e 44/ /641- N/7 To 5 4'v4-, t&)/ /0 te/1 ‘7 41 /4 /4 e4 7 / , " (JJ tisg ( AV io ce Fto u se # i& cipEw •*/:_=/ Altv6as fig oNp I A E4C.1 0 6) 4 m/6.< (-/) 7c) t. Project: NMI° 6- 61-01-c ,n4( tti it tt■v/r Project Number 0 — / - 0 Client Scale: 17924 - 140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: 425-814-8448 Fax: 425-821-2120 Designed By /4/7:7 Date. S-3 Page: ENGINEERIN G 17924 —140th Avenue NE, Suite 220 Woodinville, WA 98072-4315 Phone: (425) 814 -8448 Fax: (425) 821 -2120 Details FASTEN RTU -I TO ROOF GURB W/ IS -GA. ANGLE. 5GREW STRAP TO ROOF SLEEPERS it UNIT BASE RAIL. TWO STRAPS EACH END (4) TOTAL. ATTACHMENT DETAIL EXISTING SLEEPERS ATTACHED TO ROOF. 5x25 GLB j) I II 1 07 1 cE L XISTING 6 X SLEEP EEL A ROOF STRUCTURAL PLAN 07- T 2X @ 2' O.G. P. EXISTING 4X6 SLEEPERS. G 1/4 x 9 1/4 GOLUMS TYP. 5x28 GLB 01 OFFIC s EXISTING JOIST EXISTING PURLIN 4 S (2) ROWS OF 9 /4 "4) BOLTS ® 16 "oc STAGGERED 1 X 11Y4 L5L 7 ACTIVITY NUMBER: M08 -020 DATE: 01 -28 -08 PROJECT NAME: HERZOG GLASS SITE ADDRESS: 4344 S 104 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 1.1 Bui •I !: Division Public Works Complete Comments: Please Route TUES/THURS ROUTING: Documents/routing slip.doc 2 -28-02 REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP 61 �a, F re ve t ion Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Structural Review Required n Permit Coordinator DUE DATE: 01 -29-08 Permit Centei,cUse'•On /y„ �' i' INCOMPLETE LETTER MAILED: :s n' i71 r }a! '•ts,�•� •!� id4'F �, 1 �A�; M i•: ?•y.',• �.y• �. t, LETTER OF COMPLETENE MAILED: tt :A • Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n No further Review Required DATE: DATE: Planning Division n n Not Applicable n n DUE DATE: 02-26-08 Approved Approved with Conditions [1 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License PERFOHA15ORT Licensee Name PERFORMANCE HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600601386 Ind. Ins. Account Id 49459900 Business Type CORPORATION Address 1 25500 74TH AVE S Address 2 City KENT County KING State WA Zip 98032 Phone 4252510356 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/30/1985 Expiration Date 4/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date MILLER, DANIEL E PRESIDENT 11/27/2007 ERDAHL, DARRIN VICE PRESIDENT 11/27/2007 GOWIN, RICHARD L VICE PRESIDENT 01/01/1980 GOWIN, CONSTANCE F VICE PRESIDENT 01/01/1980 11/15/2007 Look Up a Contractor, Electric_in or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information • Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PERFOHA15ORT 02/01 /2008 FASTEN U -I TO ROOF CURB ANGLE. SCREW STRAP TO ROOF SLEEPERS UNIT BASE RAIL. TWO STRAPS EACH END (4) TOTAL. SCALE: 1/8" = 1 -0" i 1 1 I 1 i 1 1 1 1 r 1 1 1 1 1 1 1 r � r r , A 5 ••■ 1 X63 11 + f 1 5 LUNCHROOM 17 CORR. 16 _•■' - -� r• s OFFICE LS] OFFICE 06 PARTIAL ROOF HVAC PLAN SITE PLAN SCALE: 9/32 " =9'-D" ATTACHMENT DETAIL NTS y � ,•=1M1..■Ml. m•■.. EXISTING 5LEEPERE ATTACHED TO ROOF. EXISTING 6X6 SLEEPERS. r OFFICE 09 I OFFICE 05 - OFFICE REPLACE FAILED UNITS WITH NEW (2). NEVI UNITS TO BE INSTALLED IN SAME LOCATION AS EXISTING. FASTEN UNIT TO EXISTING ROOF SLEEPERS. SEE ATTACHED STRUCTURAL AND SEISMIC CALCULATIONS FOR RECOMMENDED FASTENING METHODS. CONNECT NEW UNIT TO EXISTING LINE VOLTAGE $ LOW VOLTAGE UTILITIES. CONNECT NEW UNIT TO EXISTING SUPPLY $ RETURN DUCTWORK. H OFF CE 4 _ 1... _ .. 33- .... III I I L N 11 - -•■=gm.. S 104TH PL. EXISTING 4X6 SLEEPERS. q I/4 x q I/4 GOLUMS TYP. 5x28 GLB OFFICE 02 -- MM _ - � OEN. OFFICES 01 NORTH PL 'NJ N - • -- - - - - -- • 1 1 1 BLDG. "B" 10401 MLK JR WAY N855- - EX. PARKING 1011 PL. -_.. .� EAST PL Date: Diii7a6riari Hazel $t • Fvt x r `fir St b sr W s -RATE PERMIT :i EOUIRED FOR: 0 Mechanical Electrical ' Plumbing &i Gas Piping City of Tukwila BUILDING DIVISION FILE C . Ply / Permit No. / Plar a p p r o v a l . Approval of consauceon does nAts farize • the violation of any adorted code or Ordnance. Receipt of approved F1ekf Copy and ed: City of Tukwila BUILDING DIVISION N VICINITY MAP NO SCALE KING COUNTY PARCEL NO.: 032304 '1026 LEGAL DE5GRIPTIQN: POR NW 1/4 OF SE 1/4 tl NE 1/4 OF SW 1/4 BEG AT NXN OF N LN 50 NW 1/4 WITH H MGN OF EMPIRE WAY 5 TH N 86 -58 -28 W ALG N LN SD NW 1/4 OF NE 1/4 650.x4 FT TH 5 3 -01 -32 W 24 '1.8'1 FT TO N MGN OF BOEING AGGESS RD INTERCHANGE TH N 63 -46 -45 E ALS SD N MGN 52.03 FT TAP OF CURVATURE OF A 325 FT RAD CURVE TO THE ROT TH ALG SD MGN 4 GURVE 635.1 FT TAP OF TANGENCY ON THE E MGN OF 50 BOEING ACCESS RD TH 5 4 -06 -30 E ALG SD MGN 134.84 FT 11-1 N 85 -53 -30 E ALG 5D MGN 64.41 FT TH N 34-02-42 E 133.42 FT TO SDW MGN OF EMPIRE HAY 5THN0- 02 -44E ALS 5DWMGN 480.68 FT TO P0B LESS POR DEEDED TO SOUND TRANSIT PER 5UP COURT #04- 2- 18625 -I KNT SCOPE OF WORK:: PROVIDE 4 INSTALL (2) NEVI WANE GAS PACKAGE ROOFTOP UNITS OF LIKE FOR LIKE (I) 3-TONS AND (I) 5-TON TO REPLAGE EXISTING FAILED UNITS. NEW UNIT TO BE INSTALLED IN SAME LOCATION AS EXISTING. FASTEN UNIT TO EXISTING ROOF SLEEKS. SEE ATTACHED STRUCTURAL ARID SEISMIC CALCULATIONS FOR RECOMMENDED FASTENING METHOD'S. CONNECT NEW UNIT TO EXISTING LINE VOLTAGE $ LOW VOLTAGE UTILIT1E5. CONNECT NEW UNIT TO EXISTING SUPPLY rt RETURN DUCTWORK. INSTALL (2) 7-DAY PROGRAMMABLE THERMOSTATS TO REPLACE EXIST THERMOSTATS IN SAME LOCATION. GODE NOTES:: I) SEAL DUCTS PER W.S.E.G. SEGTION 1414.1. 2) INSULATE DUCTWORK PER 1A1.5.E.G. TABLE 14 -6. 3) PROVIDE ECONOMIZER REQUIRED PER W.S.E.G. SEGTION 1433. 4) A IIOV GONVENIENGE OUTLET SHALL BE WITHIN 25' -O" OF OUTDOOR EQUIPMENT PER I.M.G. SECTION 306.4.1 5) ROOF ACCESS TO EQUIPMENT TO GOMPLY WITH I.M.G. SECTION 3065, 5) THERMOSTATS TO COMPLY WITH SECTION 1412 OF W.S.E.G. HVAC EQUIPMENT SCHEDULE TAG R11) -I RT1J -2 MANUFACTURER TRANE TRANE DESCRIPTION ROOFTOP PACKAGE HEAT PUMP ROOFTOP PACKAGE HEAT PUMP MODEL NO. YHG033AW YHG063AW NOMINAL TONS 25 5 CAPACITY - BTUH HEATING COOLING '16,000 104,000 3&,000 62,400 SEER 13.0 13.0 HSPF CFM I000 2000 E.S.P. 0.4 0.5 FAN HP .20 .33 ELECTRICAL VOLTS PHASE MCA MOCP 460 460 34) 34) 10.4 11.4 15 15 SOUND dB(A) 83 84 WEIGHT (LBS.) 531 612 OUTSIDE AIR (CFM) 200 500 REMARKS RECEIVED CITY OF TUKWILA WITH ECONOMIZER JAN 2 8 2003 WITH ECONOMIZER runlvll 1 Lclu 1 cI 1 M1 SHEET 1 OF 1 n • 4 0 1 t g I I F Herzog Glass DATE: 1/17/08 DRAWN: KB ENGR: MS APPVD: JOB NUMBER: 3131 -08 FASTEN U -I TO ROOF CURB ANGLE. SCREW STRAP TO ROOF SLEEPERS UNIT BASE RAIL. TWO STRAPS EACH END (4) TOTAL. SCALE: 1/8" = 1 -0" i 1 1 I 1 i 1 1 1 1 r 1 1 1 1 1 1 1 r � r r , A 5 ••■ 1 X63 11 + f 1 5 LUNCHROOM 17 CORR. 16 _•■' - -� r• s OFFICE LS] OFFICE 06 PARTIAL ROOF HVAC PLAN SITE PLAN SCALE: 9/32 " =9'-D" ATTACHMENT DETAIL NTS y � ,•=1M1..■Ml. m•■.. EXISTING 5LEEPERE ATTACHED TO ROOF. EXISTING 6X6 SLEEPERS. r OFFICE 09 I OFFICE 05 - OFFICE REPLACE FAILED UNITS WITH NEW (2). NEVI UNITS TO BE INSTALLED IN SAME LOCATION AS EXISTING. FASTEN UNIT TO EXISTING ROOF SLEEPERS. SEE ATTACHED STRUCTURAL AND SEISMIC CALCULATIONS FOR RECOMMENDED FASTENING METHODS. CONNECT NEW UNIT TO EXISTING LINE VOLTAGE $ LOW VOLTAGE UTILITIES. CONNECT NEW UNIT TO EXISTING SUPPLY $ RETURN DUCTWORK. H OFF CE 4 _ 1... _ .. 33- .... III I I L N 11 - -•■=gm.. S 104TH PL. EXISTING 4X6 SLEEPERS. q I/4 x q I/4 GOLUMS TYP. 5x28 GLB OFFICE 02 -- MM _ - � OEN. OFFICES 01 NORTH PL 'NJ N - • -- - - - - -- • 1 1 1 BLDG. "B" 10401 MLK JR WAY N855- - EX. PARKING 1011 PL. -_.. .� EAST PL Date: Diii7a6riari Hazel $t • Fvt x r `fir St b sr W s -RATE PERMIT :i EOUIRED FOR: 0 Mechanical Electrical ' Plumbing &i Gas Piping City of Tukwila BUILDING DIVISION FILE C . Ply / Permit No. / Plar a p p r o v a l . Approval of consauceon does nAts farize • the violation of any adorted code or Ordnance. Receipt of approved F1ekf Copy and ed: City of Tukwila BUILDING DIVISION N VICINITY MAP NO SCALE KING COUNTY PARCEL NO.: 032304 '1026 LEGAL DE5GRIPTIQN: POR NW 1/4 OF SE 1/4 tl NE 1/4 OF SW 1/4 BEG AT NXN OF N LN 50 NW 1/4 WITH H MGN OF EMPIRE WAY 5 TH N 86 -58 -28 W ALG N LN SD NW 1/4 OF NE 1/4 650.x4 FT TH 5 3 -01 -32 W 24 '1.8'1 FT TO N MGN OF BOEING AGGESS RD INTERCHANGE TH N 63 -46 -45 E ALS SD N MGN 52.03 FT TAP OF CURVATURE OF A 325 FT RAD CURVE TO THE ROT TH ALG SD MGN 4 GURVE 635.1 FT TAP OF TANGENCY ON THE E MGN OF 50 BOEING ACCESS RD TH 5 4 -06 -30 E ALG SD MGN 134.84 FT 11-1 N 85 -53 -30 E ALG 5D MGN 64.41 FT TH N 34-02-42 E 133.42 FT TO SDW MGN OF EMPIRE HAY 5THN0- 02 -44E ALS 5DWMGN 480.68 FT TO P0B LESS POR DEEDED TO SOUND TRANSIT PER 5UP COURT #04- 2- 18625 -I KNT SCOPE OF WORK:: PROVIDE 4 INSTALL (2) NEVI WANE GAS PACKAGE ROOFTOP UNITS OF LIKE FOR LIKE (I) 3-TONS AND (I) 5-TON TO REPLAGE EXISTING FAILED UNITS. NEW UNIT TO BE INSTALLED IN SAME LOCATION AS EXISTING. FASTEN UNIT TO EXISTING ROOF SLEEKS. SEE ATTACHED STRUCTURAL ARID SEISMIC CALCULATIONS FOR RECOMMENDED FASTENING METHOD'S. CONNECT NEW UNIT TO EXISTING LINE VOLTAGE $ LOW VOLTAGE UTILIT1E5. CONNECT NEW UNIT TO EXISTING SUPPLY rt RETURN DUCTWORK. INSTALL (2) 7-DAY PROGRAMMABLE THERMOSTATS TO REPLACE EXIST THERMOSTATS IN SAME LOCATION. GODE NOTES:: I) SEAL DUCTS PER W.S.E.G. SEGTION 1414.1. 2) INSULATE DUCTWORK PER 1A1.5.E.G. TABLE 14 -6. 3) PROVIDE ECONOMIZER REQUIRED PER W.S.E.G. SEGTION 1433. 4) A IIOV GONVENIENGE OUTLET SHALL BE WITHIN 25' -O" OF OUTDOOR EQUIPMENT PER I.M.G. SECTION 306.4.1 5) ROOF ACCESS TO EQUIPMENT TO GOMPLY WITH I.M.G. SECTION 3065, 5) THERMOSTATS TO COMPLY WITH SECTION 1412 OF W.S.E.G. HVAC EQUIPMENT SCHEDULE TAG R11) -I RT1J -2 MANUFACTURER TRANE TRANE DESCRIPTION ROOFTOP PACKAGE HEAT PUMP ROOFTOP PACKAGE HEAT PUMP MODEL NO. YHG033AW YHG063AW NOMINAL TONS 25 5 CAPACITY - BTUH HEATING COOLING '16,000 104,000 3&,000 62,400 SEER 13.0 13.0 HSPF CFM I000 2000 E.S.P. 0.4 0.5 FAN HP .20 .33 ELECTRICAL VOLTS PHASE MCA MOCP 460 460 34) 34) 10.4 11.4 15 15 SOUND dB(A) 83 84 WEIGHT (LBS.) 531 612 OUTSIDE AIR (CFM) 200 500 REMARKS RECEIVED CITY OF TUKWILA WITH ECONOMIZER JAN 2 8 2003 WITH ECONOMIZER runlvll 1 Lclu 1 cI 1 M1 SHEET 1 OF 1 n • 4 0 1 t g