Loading...
HomeMy WebLinkAboutPermit M08-021 - WESTFIELD SOUTHCENTER MALL - BJ'S RESTAURANTBJ'S RESTAURANT AND BREWERY 1159 SOUTHCENTER MALL M08 -021 Parcel No.: 6364200010 Address: Suite No: doc: IMC -10/06 Cityilf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1159 SOUTHCENTER MALL TUKW Tenant: Name: BJ'S RESTAURANT AND BREWERY Address: 1159 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: JARED TAYLOR Address: 1342 BELL AVE SUITE 3K , TUSTIN CA Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA Contractor License No: MERITMI163CM Value of Mechanical: $85,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT DESCRIPTION OF WORK: HVAC FOR RESTAURANT TENANT IMPROVEMENT OF NEW MALL SPACE EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 714- 258 -1808 Phone: 425 883 -9224 Expiration Date: 06/01/2009 M08 -021 03/10/2008 09/06/2008 Fees Collected: $863.19 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/ 1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment M08 -021 Printed: 03 -10 -2008 Permit Center Authorized Signature: doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • City of Tukwila • Permit Number: M08 -021 Issue Date: 03/10/2008 Permit Expires On: 09/06/2008 Date:! I hereby certify that I have read and e)cied this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied t whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performanc f k. I am authorized to sign and obtain this mechanical permit. Signature: Date:. —�� — O Print Name: G ie' /1 X`ri1 >/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -021 Printed: 03 -10 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1159 SOUTHCENTER MALL TURIN BJ'S RESTAURANT AND BREWERY 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 6: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS 10: Local U.L. central station supervision is required. (City Ordinance #2051) • Permit Number: Status: Applied Date: Issue Date: M08 -021 ISSUED 01/29/2008 03/10/2008 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 9: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 11: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) M08 -021 Printed: 03 -10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed m accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 22: To schedule all construction fire - related inspections send an e -mail to fireinsprequest @ci.tukwila.wa.us. Include your name, telephone number, permit number, project name and address and type of inspection requested. 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -021 Printed: 03 -10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. doc: Cond -10/06 M08 -021 Date: .- V/ �O ordinances governing or local laws regulating Printed: 03 -10 -2008 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/lwww.ci.tukwila.wa.us SITE LOCATION King Co Assessor's Tax No.: 4, 34) AI ()-0 061 0 Site Address: —63 F .4 f=1n441' Tenant Name: .5 NNn Property Owners Name: \ J r PLe.. U.. C. Mailing Address: \\ WS4.S'N -114 rj;.a/t? ii Lv3 ANCe t City Name: 71 AoRE.n T1r4'(Wv+, Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Mailing Address: OLk2 Owe Nv -4 E -Mail Address: c W)RVANDAE(L W'PNI (PM Company Name: . � Contact Person: E -Mail Address: Contractor Registration Number: Company Name: CA 2 - V 2 - . Mailing Address: I L \tns-r �oc yr� (�Zltb Contact Person: $C --.At �WtJ t2 E -Mail Address: V- -AN. Ck+ RNA l,Ei(Z (--t3. L M Contact Person: 1 ii - .S - i' Building Permit No. b -- 0 A: { 3 Mechanical Permit No. (t 0— 0 1 Plumbing/Gas Permit No. VG() e —o.2 -, Public Works Permit No. Project No. (For office use only) Suite Number: 3OO Floor: 1 New Tenant: g Yes ❑ .. No CA State CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone: . 7t '2. S 1 gob - rus-t- , oct 9270 City State Zip Fax Number: 71 -LSg --Z4 O I GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record M , Szze $C) i t ►-s 75< - 62.41 Zip Day Telephone: Z i y — S $2307 Fax Number: 21 - roSSS1 001K City State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: C t t-Tarz � Mailing Address: 142D `"SEC -. 1 A '1ockx.r4,.t32n.a , T4.4..4s 1 X - 7 2-47 City State Day Telephone: 2 (y -G/W _ $(0J Zip E -Mail Address: ESN• SA 12I &C• -(3 COM Fax Number: Zf c G c-g- 06 1K Q:\Applications\Fomw- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh 9vr>2S— i 7L-ti( Zip Page 1 of 6 Unit Type: Qty Unit Type: 1 Qty t Unit Tyree: I Qty Boiler/Compressor: Qty Furnace 100K BTU ' Air Handling Unh >10.000 FM — Fire Damper — 0.3 HP!100.000 BTU Z Furnace>IOOK BTU q Evaporator Cooler — DiBLser 5U 3-15 HP /500,000 BTU Flour Furnace _ Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1.000.000 BTU — Suspended/W m oor — V on System _ Wood/Oas Stove — 30-50 HP /1,750,000 BTU Appliance Vent _ Hood and Duct = Emergency Generator _ 50+ HP/1.750,000 BTU _ Repair or Addition to 1 Cooling Srilent - Incinerator - Domestic - Other Mechanical Equlp — Air Handling 0,000 CFM Unit a t Incinerator— Comm /Ind - i • E tem.1'EEMi'1' TFO1MA - 206-431; l0 MECHANICAL CONTRACTOR INFORMATION Company Name: r, IS. D. Mailing Address: cuy Contact Person: Day Telephone: E Address: Fax Number: Contractor .Registration Number. Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 435090 Scope of Work (please provide detailed information): el7/K iFtETT I NS7.4 L LA DD)) ID)) O F ,E V 1/AG Sy4iuM rOZTE./JAkIT FW ESti OUT ,Ad MEW e,00 bug' 5K14 AVSr AA > AA KEUP At re SNISTEA1 Cads /STEArr w't T14 FUUt .5Ek via k irct a). Dm Residential: New .... ❑ Replacement .... ❑ Commercial: New ....121 Replacement .... ❑ State Zip fuel Type: Electric ❑ Gas.... Other: Indicate type of mechanical work being installed and the quantity below: R n•1r+e®.Ayplteeueo.ammimeO4006. Ranh Ayplmsikadoe Revised 94006 bb Page4of6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS$ O =HORIJP AGENT: Signature: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be - requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). Print Name: �rA -..Et Mailing Address: i? - 2_ Date Application Expires: Date Application Accepted: x-29 -Gg Q: ApphcahonsWonns- Applications On Line\3 -2006 - Permit Apphcation.doc Revised: 9 -2006 bh Day Telephone: City Date: 1 /'Z -s1b1$ C R2-7 ,5o State Staff Initials: Z ip Page 6 of 6 Dnc: RECSE'PS -OR RECEIPT NO: R08 -00673 Initials: WER User ID: 1655 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.11www.d.tukwila.wa.us Payee: SHAWMUT DESIGN AND CONSTRUCTION SET ID: 0310 SET NAME: BJ SET TRANSACTIONS: Set Member Amount M0:8 r2kJ 1,056.55 PGO8 -026 1,502.90 TOTAL: 2,559.45 ACCOUNT ITEM LIST: Description GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES SET RECEIPT Payment Date: 03/10/2008 Total Payment: 2,559.45 TRANSACTION LIST: Type Method Description Amount Payment Check 223735 2,559.45 TOTAL: 2,559.45 Account Code Current Pmts 000.322.103.00.0 186.90 000/322.100 696.55 000/345.830 720.00 000.322.103.00.0 956.00 TOTAL: 2,559.45 9669 03110 9710 TOTAL 2559.45 Receipt No.: R08 -00243 Initials: WER User ID: 1655 Payee: FRANCHER DEVELOPMENT SERVICES ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -021 Address: 1159 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/29/2008 Applicant: BJS RESTAURANT AND BREWERY Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Check 2841 166.64 Account Code Current Pmts 000/345.830 166.64 Total: $166.64 • Payment Amount: $166.64 Payment Date: 01/29/2008 11:14 AM Balance: $696.55 7775 01/29 9710 TOTAL 767.87 0 doc: Receiot -06 Printed: 01 -29 -2008 Proj s T of spection: (A) 4 - Aldie q I Date Called: Special Instructions: Date --7_ — 7 ` 0 O l a.m. Requester: Phone — F36 - ,3 7a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3,670 N Approved per applicable codes. Corrections required prior to approval. COMM ENTS: .. Corr e. T` b but et) wip /e°O ' F'n eiY, /ems L (1? IDate Inspector: ❑ $60. i i INSPECTION FEE REQUIRED. Prior to inspection, fee must be pai . . 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: T y pe i'r Inspection: / CA 21 Address: 1 I j . q M i..../., Date Called: Special Instructions: Date Wanted: .. / , a.m. Requester: Phone No: 5 VYl t B -O24 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 IA Approved per applicable codes. Corrections required prior to approval. COMMENTS: pc t" Inspector Date: - 7/ 3/0 . ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: � �p ,,// ^ / p� / / �"wf c'.",n hg 54 e d �.! �, TLJ t , e. 40if i e deeii . Address: 11 S'? 2 • SeGl,c..t' c te4 iletra tAaitt Date Called: 3 , cod IA a4‘ s�+r etI) reds e464 i.c.,dA5 Special Instructions: V. ,Aile GitoAai4ote,q / - L476,- l /sec) L)Jd l+ pride. 4e5 Week 41 !9 Requester: Project: 13.7 s ges NAX1 F Type of Inspection: (`1 A F'. . Address: 11 S'? jx Date Called: Special Instructions: Date Wanted: 7 3W ' . il: p.m. Requester: Phone No: 4 / Lj 15 rsr INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Egi Corrections required prior to approval. t Inspector: Date: 7 ,We E1 $60.00R E' INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid att6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: Project: Tv a of Inspection: Address: , K MALI- Date Called: Special Instructions: Date Wanted: 7/1 /oc a.m. Requester: Phone No: qZ S - 705(` z L i 7 (a INSPECTION NO. Inspector: INSPECTION RECORD Retain a copy with permit Date: MOT "0 / N 1Z' (206)431 -36 PERMIT NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: p n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: /f � ' s Type of Inspection: _0 Address: 115'-QZI, Date Called: Special Instructions: Date Wanted: // //y� a. (D/4 /d e p.m. Requester: Phone No ii.25 Y 9-117g 'INSPECTION RECOkb Retain a copy with permit INSPECTION Nb. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 0 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. 1110 fi- o .2_ 1 El Corrections required prior to approval. COM / . — All d s /ii Jl d-td )ausQ. / t dial 9 t&52 lc 4,7 tie✓ ®rc) 2" tl . Date: 6/./® se El $60. a 0 ' EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid : 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: :u6'u;.aHL"•■ svd 641 "'`.a WAVABi ':oi "�T _- b •x""a ' i %- Lia.4.i ' Pro' ct: S.PS- ri.t� Type of Inspection,: '�..tc S. Address: i I 4- t Date Called: Special Instructions: Date Wanted: !� 46 - Z9 -0( p.m. Requester: Phone No: '-/z S -2v 2 7 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -36 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: V 4'U l /fig c4ii71 11,1 rr STr7�P P# So i br l lake- Inspector: Date: 51/4 4/ar D $58.0 NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: COMMENTS: tv* 0 40 ry5b4...(ctie *c.,-/-5 / A 5- rem+ satoZ) Address: I 1 c s d ) C 1 M A- ( 1 0 4 4-z) c_dolgr hAy-dli l re..51-e60a45 A44 a' t iviza A ees Special Instructions: Date Wanted: •C '' — ? 7 - 0 f CZ p.m. Requerrer: Phone No: " 1 2 2 1 Project Type oknspection; , U. A (-9 IA — i wVi Address: I 1 c s d ) C 1 M A- ( 1 Date Called: Special Instructions: Date Wanted: •C '' — ? 7 - 0 f CZ p.m. Requerrer: Phone No: " 1 2 2 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /14- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-3670 0 Approved per applicable codes. El Corrections required prior to approval. Inspector: Date: 4 4 0 $58.0 2 INSPECTION FEE REQUIRED. Prior o inspection. fee must be paid ( 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: -.F.attffra.%4) Projec t Type of I pection: A //.1 5 171/1// Date Called: Special Instructions: Date Wanted: -3-- / -Qg p.m. Requester: Phone No: 6/7 - gG 9 —3 7a ) INSPECTION RECORD Retain a copy with permit f - e/ INSPECTION NO. PERMIT NO. D Approved per applicable codes. • 0 $58.QO„A INSPECTION FEE REQUIRED. Prior to inspection. fee must be paid'3t 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. CITY OF TUKWILA BUILDING DIVISION l e-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: e'AAc_ Dull — ff ,11 suit; C S' (' 1 PL14'Q v1 145 biklyi CA4 reA i t O n Inspector: Date :� 6 / 6i..../ Receipt No.: Date: Pro Type J3 ec f to : Address: ItG v -( 1 Date Called: Speciarin Date Wanted: 3 — B--IC) Requester: Phone No:_ 5 2c e tin; PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2'06)431 -3670 INSPECTION NO. INSPECTION RECORD Retain a copy with permit in 08 -152 I ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: �� 4 D e 7b /S2/6 Insp ctor: ) Dat $5 . l(REINSPECTIO FEE REQUIRED. Prior to inspection, fee must be p Jat 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Date: Receipt No.: Project: S 71 Type o Inspection: d,/4,t -, Address: X45 m // Date Called: Special Instructions: Date Wanted: 5 —J , _ Q� a.rrr p.m. Requester: Phone No y 2 5 - 2483 - 2 4 / 7 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. /92/8- PER NO. (206)431 -3670 0 Corrections required prior to approval. COMMENTS: Q� /2/Ah.:1./ 1,4 - z f 2 RI- 2d. Gv(p0fws d err Gr 7"62 I pect .0 0 REINSPECTIO FEE R U 7 Date: D S RED. Prior o inspection. fee must be p id at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: COMMENTS: p 4 i P A (444/5- .1, An(s ©r• •cam ,..,)G..e Mork Jo ✓ W /i /5 -rev f " iNS a arvre, h?/,v9, Date Called: A''74.-• 4,r x ° ; Bv - h' "iiini. ei.e Date Wanted: 6 -- 7 -4) { 4) Requester. Phone No 142.5 -2 )t 2 V'7 3 ,------. / N. Project: i 60C(A.) f C Ll Type o Inspection: 46 h- ) nj Address: ( Date Called: Special Instructions: Date Wanted: 6 -- 7 -4) { 4) Requester. Phone No 142.5 -2 )t 2 V'7 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 0 Approved per applicable codes. Corrections required prior to approval. In' pect Date: :.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be id at 6300 Southcenter lvd.. Suite 100. Call the schedule reinspection. Receipt No.: rate: COMMENTS: Sprinklers: Typc of Inspeebon: Address: Suite #: r-i--) • kl,,,, p4 ON . f . ..). 1 gi,V- CA.1\1(1 Special Instructions: \_...-- Phone No.: j- 33-0 1 . 2 ------ ) C L) 1 - S. k-F '-'1 7 c ) 0 1 4 Pt■az...\) AA vck 1 C_ C Li t E- (,_ c u N ( / 0 -00 r) 1:6 N 0- T t Gi•-i< • IT v2- t C CL ( pt C) 133 . -- li) M „A-NAc- • : . . . .,„ Project: t '( Sprinklers: Typc of Inspeebon: Address: Suite #: eV\ , Contact Person: T 0 t`..4 141-J Special Instructions: Occupancy Type: Phone No.: j- 33-0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre-Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila. Wa. 98188 206-575-4407 Word/Inspection Record Form.Doc 1/13/06 • 0 .P) PERMIT NUMBERS –7 required prior to approval. Inspector: 4 ` (AhaAfA / Date: Hrs.: ( $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location RTU -1 Lennox TGA240H2B 248 8000 ECONO 10.80 Ef -2 Roof RTU -2 Lennox TGA240H2B 248 8000 ECONO 10.80 Greenheck Roof RTU -3 Lennox TGA24OH2B 248 8000 ECONO 10.80 CUBE -141 -7 Roof 0.40 0.75 cv Kitchen EF -5 Greenheck GB -091 600 0.50 0.25 cv Restroom MAU -1 Greenheck DGX- 115 -522 6600 0.50 5.00 cv Kitchen 95 Fan Equipment Schedule 1 'CII ut iuhmm "z Equip. ID Brand Name' Model No.' CFM SP HP /BHP I Flow Control bUILVIs't7 9J1t LJ1 Location of Service EF -1 Greenheck CUBE- 180HP -15 4472 2.00 1.50 cv Kitchen Ef -2 Greenheck CUBE- 180HP -15 4954 2.00 1.50 cv Kitchen EF -3 Greenheck CUBE-1808P-15 1800 1.00 1.50 cv Kitchen EF -4 Greenheck CUBE -141 -7 400 0.40 0.75 cv Kitchen EF -5 Greenheck GB -091 600 0.50 0.25 cv Restroom MAU -1 Greenheck DGX- 115 -522 6600 0.50 5.00 cv Kitchen 95 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh_. _Output-Btutr .....•— (` a. narst 7Effieiency+a u .r. TAAl For Building Dept. Use PILE - y Tukwila, WA 98188 Applicant Name: I KICV11L.mve..v Applicant Address: 1420 W. Mockingbird Lane Suite 800, lop at Il 'LIL_ L. '1...A..1 - i i 1—a., .. , ®° 9 AV l+" t CLo 9' L iid 1 .-., . „ nnnr. N r-tu ., U L um, Project Info Project Address BJ's Brewhouse Date 1/25/2008 633 Southcenter Pkwt Suite R4 For Building Dept. Use PILE - y Tukwila, WA 98188 Applicant Name: D, Scott Hindle Applicant Address: 1420 W. Mockingbird Lane Suite 800, lop at Applicant Phone: 214 - 920 - 8100 ®° 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. Includes Plans Oy The work includes installation of (3) HVAC systems sumniing•to 60 tons, id luding (2) j greasy exh~a"tl'stfa - �' s s, ,.,,._, �'� . Q (2) non - grease exhaust fans, and a make -up air unit for kitchen hoods. The system also includes kitchen m hoods, supply, return, exhaust and grease exhaust ductwork, grilles, registers, diffusers, complete eontrii; C', ' 77 ( at system and related items necessary for a complete functioning system as indicated on the plans. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option Simple System O Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. MO8O }.4C H FCi 1 1f available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. ° COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). *e 9 2008 'wily!' 1 CENTER System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: E Constant vol? LI Split system? Air cooled? E Packaged sys? <20,000 Btuh? Economizer included? If Heating Only: <5000 cfm? <70% outside air? 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. START ) Heating Only Reference Section 1421 otal Ca . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Simple System Allowed (section 1420) I Reference Section 1423 Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location Tukwila, WA 98188 Applicant Name: D, Scott Windle Applicant Address: 1420 W. Mockingbird Lane Suite 800, TX 75247 Applicant Phone: 214 - 920 -8100 Fan Equipment Schedule Equip. ID Brand Name' Model No. CFM Sp HP /BHP Flow Control Location of Service Efficiency Tukwila, WA 98188 Applicant Name: D, Scott Windle Applicant Address: 1420 W. Mockingbird Lane Suite 800, TX 75247 Applicant Phone: 214 - 920 -8100 Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency Tukwila, WA 98188 Applicant Name: D, Scott Windle Applicant Address: 1420 W. Mockingbird Lane Suite 800, TX 75247 Applicant Phone: 214 - 920 -8100 Project Info Project Address BJ's Brewhouse Date 1/25/2008 633 Southcenter Pkwt Suite R4 For Building Dept. Use Tukwila, WA 98188 Applicant Name: D, Scott Windle Applicant Address: 1420 W. Mockingbird Lane Suite 800, TX 75247 Applicant Phone: 214 - 920 -8100 2006 Washington State Nonresidential Energy Code Compliance Forms Mechanical Summary MECH -SUM Project Description Briefly describe mechanical system type and features. ❑ Includes Plans 2006 Washington State Nonresidential Energy Code Compliance Form Include documentation requiring compliance with commissioning requirements, Section 1416. Revised July 2007 Compliance Option O Simple System l) Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 'If available. 2 As tested according to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: — <5000 cfm? [ <70% outside air? Mechanical Summary (back) MECH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Simple System Allowed (section 1420) 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 l otal Ca . wo economize <240,000 Btuh or 10 %? Heating /Cooling or Cooling Only Reference Section 1423 Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Mechanical - Complex Systems Checklist MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Add BJ's Brerhouse Date 1/25/2008 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH - CHK checklist for additional system requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY 1431.1 Field assem. sys. Provide calculations 1432.1 Setback & shut -off Indicate separate systems or show isolation devices on plans 1432.2.1 Air system reset Indicate automatic reset 1432.2.2 Hydronic System Indicate automatic reset, cooling tower, & heat pump loop valves 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption and demonstrate 10% higher efficiency for equipment with out economizer. 1433 Water Economizer Indicate water economizer and provide calculations if 1433 Exception 2 is utilized 1434 Separate air sys. Indicate separate systems on plans 1435 Simul. htg. & clg. Indicate that simultaneous heating and cooling is prohibited, unless use of exception is justified 1436 Heat recovery Indicate heat recovery on plans; complete and attach heat recovery calculations 1437 Elec. motor effic. MECH -MOT or Equip. Schedule with hp, rpm, efficiency 1438 Variable flow sys. Indicate variable flow on fan and pump schedules 1439.1 Kitchen Hoods Indicate uncooled and unheated make -up air 1439.2 Fume Hoods Indicate VAV, unheated /uncooled or heat rec. makeup no is circled for any question, provide explanation: Decision Flowchart Use this flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for more complete information on the requirements. Start Here Section 1411.1 Equipmen Efficiency Shall Meet Tables 14 -1A through 14 -1G 2006 Washington State Nonresidential Energy Code Compliance Form as/Oil Fuma input > 225,000 tuh or Gas/O' 't Heat Any Fuel Fuma input 225,000 Btuh? Air System Serving Multiple Zones? apacity of H Heating System > 00,000 Btuh') Yes 1411.1 Intermittent Ignition Device & Power Venting or Damper. If input a. 225,000 Btuh then 1412.6 Modulating or Staged Combustion Controls Required Yes 1411.1 0.75% Maximum Jacket Loss Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required (continued on back) Yes Section 1432.2.1 Supply Air Reset Controls Required Yes Section 1432.2.2 Hot Water Supply Temperature Reset Required No 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical - Complex Systems (back) MECH -COMP 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 0% Air Econ Provided? Section 1413 Water Cooled w/Water Econo? Total Clg Capacity w/ Water Econo <500 Tons? pply Air >5,0 cfm & OSA > 70% otor Incl. i qpmt. Coved by Tb114- 1A -14- 1G? Section 1436 50% Effective Heat Recovery Required Yes Yes Yes Yes No DONE EER 10% Better No P than Code No • Yeses Yes-■ Yes-• tal Cap. cono <= 480,00 Btuh or 20% of otal Cap.? Yes Yes Multi -speed Motor in Multi - eed system? Yes ystem or Zon w/ Simultaneous Htg. & Clg.? Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating /Recooling No Yes ► Section 1439.1 No Heating or Cooling for at Least 50% of Make -up Air Yes No—■ Yes-■ Section 1433 Economizer Required 1 Yes Section 1437 Motors Must Meet Efficiencies in Table 14-4 1 Yes Application Involves Variable Flow? otal Bldg. Fum Exhaust > 15,000 cfm? Section 1438 Variable Flow Devices Required Yes Section 1439.2 One Required: a. 50% VAV Exhaust & Make -up b. 75% Direct Makeup w/ Tempering Only c. Heat Recovery per 1436 d. Constant Volume w/ < 50fpm Face Velocity Yes Open Motors Closed Motors 3,600 1,800 1,200 3,600 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). Motor No. or Location Minimum Nominal Full-Load Efficienc Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 HP 2006 Washington State Nonresidential Energ Code Com•liance Form BJ's Brewhouse Type (open /closed) Description of Application or Use Date Synch. Speed 1/25/2008 For Building Department Use Revised July 2007 Min.Nom. Full load Efficiency Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14-1B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Bays Brewhouse 'Date 1/25/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg_ Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage yes 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule yes 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas yes 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule yes 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yes 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements n.a 1416.2.1 Commissioning Provide commissioning plan yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report yes 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank yes 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 yes 1452 Heater Efficiency Indicate pool heater efficiency n.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per budding. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity Tess than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Cooling Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 1412.8 Ventilation Controls for High - Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per budding. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity Tess than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying • • 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6 Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) JE • JACO : S Carter Burgess These drawings /documents are being submitted by Carter & Burgess Inc. Carter & Burgess, Inc. is a wholly owned subsidiary of Jacobs Engineering Group Inc and hereinafter referred to as Jacobs Carter Burgess. February 22, 2008 Mr. Dave Larson, Sr. Plans Examiner Tukwila Building Division 6300 Southcenter Blvd., #100 Tukwila, WA 98188 Phone: 206 -431 -3678 Re: BJ's Restaurant and Brewery 1159 Southcenter Mall Mechanical Plan Check# M08 -021 Dear Mr. Larson: • This letter is the written response to comments dated February 7, 2008. Below are responses per your requirements and comments, please reference Delta 3 on the applicable drawings. RE: Permit #M08 -021 (Mechanical) 1. Please provide structural plans and details relative to the addition of the new rooftop equipment provided under this permit application. This should include framing details for reframing around holes cut through roof structure. Structural calculations may be necessary if the additional loads were not accounted for elsewhere. Response: Per the lease agreement between this Tenant and Westfield, the structural design and detailing for all rooftop equipment including RTU's/ Fans/ etc. will be performed by Westfield's shell building structural Engineer of Record under a separate scope of work not included in these documents. 2. Please provide a separate plan for grease and steam exhaust systems. Elevations would be helpful to show entire systems from hoods to roof. Show locations of required cleanouts. The plan notes mention a shaft as well as installation of a fire blanket and the rooftop termination detail shows vented openings the top of the rated shaft. Please show shaft details including fire rating, and /or fire wrap blanket on grease exhaust duct, access doors to grease cleanouts and clarify how maintenance people will access these required cleanouts. The duct support details should be shown on elevations at locations designed to carry gravity and seismic loads. Response: Please refer to sheet M1.0/ Detail #2 for single line riser diagram of exhaust ducts and shaft. Details for fire wrap and cleanouts have been added to sheet M2.0. Please refer to the Kitchen K -8 sheets for additional information regarding the hoods and manufacturer information. 3. Please confirm that duct detectors are to be on air return side of ventilation systems. Response: Please refer to sheets M1.0 & M2.0 for revision of smoke detectors from supply to return sides of the HVAC rooftop units. 4. Please verify that combustion exhaust outlets on rooftop gas units are located 10 ft. away or 3 ft. above air intakes of adjoining units. RTU 1,2and 3 are less than 4 ft. apart and the exhaust from one unit could impact the fresh air intake of the other. Manufactures spec. sheets would be helpful to show compliance. Response: The site specific conditions preclude our ability to coordinate rooftop units in any other locations than currently shown. Please refer to sheet M2.0/ Packaged Rooftop Unit Schedule for added note that RTU's 1 &2 will be field equipped with manufacturer available combustion exhaust flue vertical extension kits. 5. The total makeup air exceeds the exhaust air by1574 cfm. Section 501.3 of the IMC requires spaces with exhaust systems to be maintained in a neutral or negative pressure condition. Please address this section as it relates to the entire mechanical system. Response: Consistent with industry standard restaurant design, the Kitchen area (having significant exhaust requirements) is maintained in a negative air pressure, while the Dining & Bar area is maintained in a positive air pressure. To maintain heat, odors, and correct operation of capture and containment at the exhaust hoods, the positive pressure air from the Dining migrates to the negative pressure Kitchen. Please refer to the Air Balance Schedule on sheet M2.0 for indication that the Kitchen area is negative ( -2626 cfm) and the Dining area is positive (4200 cfm) and that the net pressure for the tenant space is 1574 cfm. Please feel free to contact me with any questions or comments at your earliest convenience. You can reach me directly at 214.920.8100. Sincerely, an Broussard Project Manager Jacobs Carter Burgess • 1 Jacobs Carter Burgess Page 2 of 2 1 ukwila Building Division Mechanical Review (Resubmittal) Febivary 22 2008 February 7, 2008 Jared Taylor 1342 Bell Avenue, Suite 3K Tustin, CA 92780 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -021 BJ's Restaurant and Brewery —1159 Southcenter Mall Dear Mr. Taylor, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson, at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Brenda Holt Permit Coordinator encl xc: File No. M08 -021 • Cizy of Tukwila [10(K P:\Permit Center \Correction Letters \2008\M08-021 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: February 5, 2008 Project Name: BJ's Permit #: M08 -021 Plan Review: Dave Larson, Senior Plans Examiner Tukwila Building Division Dave Larson, Senior Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide structural plans and details relative to the addition of the new rooftop equipment provided under this permit application. This should include framing details for reframing around holes cut through roof structure. Structural calculations may be necessary if the additional loads were not accounted for elsewhere. 2. Please provide a separate plan for grease and steam exhaust systems. Elevations would be helpful to show entire systems from hoods to roof. Show locations of required cleanouts. The plan notes mention a shaft as well as installation of a fire blanket and the rooftop termination detail shows vented openings the top of the rated shaft. Please show shaft details including fire rating, and /or fire wrap blanket on grease exhaust duct, access doors to grease cleanouts and clarify how maintenance people will access these required cleanouts. The duct support details should be shown on elevations at locations designed to carry gravity and seismic loads. 3. Please confirm that duct detectors are to be on air return side of ventilation systems. 4. Please verify that combustion exhaust outlets on rooftop gas units are located 10 ft. away or 3 ft. above air intakes of adjoining units. RTU 1,2and 3 are less than 4 ft. apart and the exhaust from one unit could impact the fresh air intake of the other. Manufactures spec. sheets would be helpful to show compliance. 5. The total makeup air exceeds the exhaust air by1574 cfm. Section 501.3 of the IMC requires spaces with exhaust systems to be maintained in a neutral or negative pressure condition. Please address this section as it relates to the entire mechanical system. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -021 DATE: 02 -26 -08 PROJECT NAME: BJ'S RESTAURANT & BREWERY SITE ADDRESS: 1159 SOUTHCENTER MALL Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued Original Plan Submittal DEPARTMENTS: in G Bu ding Mon Mon Public Works ❑ Comments: Documents/routing slip.doc 2 -28-02 Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete F Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: Planning Division ❑ Permit Coordinator DUE DATE: 02-28-08 Not Applicable ❑ No further Review Required DATE: DUE DATE: 03 -27-08 Not Approved (attach comments) n DATE: iPerinitCenter Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: 1)( dt Building Division Public Works ❑ Complete TUESITHURS ROUTING: Please Route Documents/routing slip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M08 -021 DATE: 01 -29 -08 PROJECT NAME: BJ'S RESTAURANT & BREWERY SITE ADDRESS: 1159 SOUTHCENTER MALL X Original Plan Submittal Response to :Correction Letter # Response to Incomplete Letter # Revision ;# • After Permit Issued Incomplete Comments: DETERMINATION OF COMPLETENESS: (Tues., Thurs.) III Avg/ I - 3 Fire Prevention Structural ❑ Permit °Cen'wr Use °Only;. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: APPROVALS OR CORRECTIONS: Structural Review Required Planning Division Permit Coordinator DUE DATE: 01 -31 -08 Not Applicable ❑ No further Review Required REVIEWER'S INITIALS: DATE: DUE DATE: 02 -28 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.cLtukwila.wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: D Plan Check/Permit Number: M08-021 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 RECEIVED r'rr r w rl IKWILA ❑ Revision # after Permit is Issued FEB 2 6 2006 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: BJ'S RESTAURANT AND BREWERY Project Address: 1159 Southcenter Mall Contact Person: Jared Taylor Phone Number: ?T - g5 p Or- Summary of Revision: REFEI'R TD A-T-r }4.61) Sheet Number(s): irwi> I. I m 1.0 Ili 2 .O "Cloud" or highlight all areas of including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 02 Z 1 -'b \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: u,1?9 'ERMn CENTER License Information License MERITMI163CM Licensee Name MERIT MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600517946 Ind. Ins. Account Id 46817500 Business Type CORPORATION Address 1 PO BOX 2109 Address 2 City REDMOND County KING State WA Zip 980732109 Phone 4258839224 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/14/1984 Expiration Date 6/1/2009 Suspend Date Separation Date Parent Company Previous License Next License AUTOMMC044QH Associated License Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V PRESIDENT 02/14/1984 Bond Amount KIRKWOOD, JOAN M SECRETARY 02/27/2006 FRICKBERG, WILLIAM MICHAEL VICE PRESIDENT 02/27/2006 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Look Up a Contractor, Elect * or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MERITMI163CM 03/10/2008 • MEP ROOF PLAN KEYED NOTES 1 PROVIDE 6 AMP IN -UNE FUSE PER PHASE IN WEATHERPROOF JUNCTION BOX AHEAD OF MANUFACTURER SUPPLIES 1 MOTOR SWITCH. O PROVIDE 4 AMP IN -LINE FUSE PER PHASE IN WEATHERPROOF JUNCTION BOX AHEAD OF MANUFACTURER SUPPLIES MOTOR SWITCH. O PROVIDE 4 AMP IN -UNE FUSE PER PHASE IN WEATHERPROOF JUNCTION BOX AHEAD OF MANUFACTURER SUPPLIES 3 MOTOR SWITCH. O PROVIDE 3 AMP IN-LINE FUSE PER PHASE IN WEATHERPROOF JUNCTION BOX AHEAD OF MANUFACTURER SUPPLIES MOTOR SWITCH. ® THE CONVENIENCE RECEPTACLE AND DISCONNECT SWITCH ARE FURNISHED WITH THE UNIT. O MOTOR SWITCH FURNISHED WITH THE UNIT PROVIDE 24" FLEXIBLE LOOP CONNECTION TO UNIT FOR HINGED ACCESS. O WEATHERPROOF JUNCTION BOX ON ROOF FOR EXTERIOR SIGNAGE VERIFY LOCATION PRIOR TO ROUGH-IN PROVIDE WP DISCONNECT SWITCH FOR SIGN. 4 GFI RECEPTACLE IN WEATHERPROOF JUNCTION BOX FOR SATELLITE ON ROOF PROVIDE 2" CONDUIT TO ACCESSIBLE CEIUNG ABOVE OFFICE VERIFY SATELLITE LOCATION PRIOR TO ROUGH -IN. (1) PROVIDE LIGHT SENSOR AND MOUNT SO SENSOR IS FACING NORTH WITH NO OBSTRUCTIONS IN FRONT OF SENSOR. 1 D PROVIDE A NEMA 3R, 30 AMP, 3 PHASE NOF USED DISCONNECT SWITCH. 11 PROVIDE 312, 3/4" CONDUIT FROM CONDENSER ON ROOF TO COOLER BELOW. SEAL ALL ROOF PENETRATIONS. g PROVIDE A WEATHERPROOF JUNCTION BOX ON ROOF FOR EXTERIOR LIGHTING. 13 PROVIDE 1" CONDENSATE DRAIN TRAP AND VENT AND EXTEND DOWN THROUGH ROOF AS SHOWN. REFER TO SHEET P1 :I FOR CONTINUATION. e NOT USED. 15 COMBUSTION AIR INTAKE VENT FOR GAS FIRED WATER HEATERS. COORDINATE ROOF PENETRATION, FLASHING AND COUNTER- FLASHING WITH THE GENERAL CONTRACTOR. 16 COMBUSTION AIR EXHAUST FLUE FOR GAS FIRED WATER HEATERS. COORDINATE ROOF PENETRATION, FLASHING AND COUNTER - FLASHING WITH THE GENERAL CONTRACT')R. 17 EXISTING PRIMARY/ OVERFLOW ROOF DRAINS TO REMAIN. PLUMBING CONTRACTOR SHALL COORDINATE ANY REQUIRED LEADER PIPING ADJUSTMENTS WITH THE FRAMING PLAN. /7 'ROUTE 3/4" COLD WATER UP THROUGH ROOF, CONNECT TO FREEZEPROOF HOSEBIBB MOUNTED THROUGH ROOFCURB. REFER TO PLUMBING DETAIL ON SHEET P4.0 FOR ADDITIONAL INFORMATION. 19 LIGHTING LOCATED IN UPPER COVE ABOVE LOWER ROOF. 20 3" VTR. INSTALLED LOCATION SHALL BE A MINIMUM OF 10' 4" FROM ANY OUTDOOR AIR INTAKE. 21 2 "GAS UP THRU ROOF AND CONNECT TO MAKE -UP AIR UNIT WITH DIRT LEG AND , SHUT OFF VALVE. u J 1 i '21=6; till;!I.. Ei!.1I1[)1NG R14 HE,I.I, BUIL`)ING - RE_IEI' HOOD SERVICE ACCESS DOOR FROM STAIRWELL LANDING TO FIRST FLOOR ROOF. COORDINATE INSTALLATION WITH LANDLORD GERAIION RACK CONNECT TO REFRIGERA110Ji RACK BREAKER WITHIN INTEGRATED SWITCHBOARD. , SHEET; E20 200A/NF WP ; N '-SHELL 'HUILDING EXHAUST1AN MALI -1 1285 LBS. SCALE: 3/1 6"=1'-0" - 39 M -04/6 WP I I 1ST FLOOR ROOF t om\ si; :Ss MEP ROOF PLAN \ CL EARANC ' O/A INTAKE � J \ FOOTPRINT FROM - \ b 1 \\ . ' i \\ KU-1 (20 TON) 288 MBH �N 2860 LBS a KB-23 92 0 19 KB- 19 B2 0 / B2 0 ® • B2 0 19 \ \\ • KB-23 KB-23 I(6-23 KB-23 � KB-23 R1U -2 (20 TON) 286 MBH 2860 LBS / / / / / / SHF.I.! BUI.DING k IJ KA -39 WP.GFCI M- 13;1517 60 /NF/3P • 0/A INTAKE s .. j R111 7 1 . - '02 0 L -16 KB-23 '.1-1120 19 ' 19 •' O , KB-23 / / / \ \ / / % / ' \ 24 SHELL 8!JILL'I'dG F.XH�IJ`;I FAN 1 1 1 1 L 1 . ( TON) 288 MBH 2860 LBS \--SHELL E RELIEF 11000 / KA -39 WP,OFCI M- 19,21'23 60A/NF/3P i /'B2 0 19 KB -23 %",V L 15''B20 19 KB-23 J/ , ;E +I:.1. f31;!t1JING RFL? - HOOD SEPARATE PERMIT REQUIRED FOR: C"] Moitarncai LYEtec trical p lumbing Gas Piping City of Tukwila BUILDING DIVISION • ✓ i Si-ELL BU!!_DING RTU'• i .;% '," ;60 ��• KB-23 -'/ KB--23 1 J SHELL EU`•':.61NC RTU 7 \ 25 RECE"JED CITY OF FEB 2 6 2008 PERNI1; e IT 20 'CB -23 20 t9 23 20 19 EI - .._ B20 19 KB -23 E 20 ® KB -23 kB- 1 2 L -1O� i City of TuIcwvia BUILDING DIVISION of work whom :-T, - _Q tv8ti of Tukwila Su :ding .. rt. • Revisions will require a new ° an submittal 1 l may include additional plai ►€ fees. / • i C c UD i r9'I�hi°I�c ^y l i a ` U \1'ed iF � s Y -. • _ . • view approval is erthject to : • - and ornl i oras. aI of construction • r 1 _ t- does not authorize anon of any aged code • ordinance. Repeipt ved Reid..�.;_ � lged: // \ " .1 L--12 ' I r 54 COF4CTION LTR# 0 Carter4urgess CARTER 8 BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, !80O DALLAS, TEXAS 75247 -4925 EXPIRES: 09 -30 -2008 02.22.2008 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 INLINE C&B JOB NUMBER: 024203.014 DATE ISSUED: 0125 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT 11/30/07 01 /25/08 REVISIONS: 5 CITY ELEC CMNTS 2/22/08 SHEET CONTENTS: MEP ROOF PLAN SHEET NUMBER: MEP1.1 1. 2. 3. 4. 5. MECHANICAL G E N E FOAL NOTES MECHANICAL KEYED NOTES LAY —IN CEILING IN COMPLIANCE WITH IMC 2006 506.3.9, PROVIDE CLEANOUTS AT EVERY DUCT CHANGE IN DIRECTION (TYPICAL) 2ND FLOOR KITCHEN LAY —IN CEILING GROUND FLOOR HOOD -5 DISH WASH SCALE: NOT TO SCALE EF -1 EF -4 EF -3 EF -2 I 1 1 1 1 1 1 1 IN COMPLIANCE WITH IMC 2006 506.3.10, TYPE 1 GREASE EXHAUST DUCTS SHALL BE EXTERNALLY WRAPPED WITH UL LISTED FIRE WRAP SYSTEM PER MANUFACTURER'S INSTRUCTIONS HOOD -3 COOK LINE 15/12 15/12 HOOD -2 TYPE 1 GREASE EXHAUST AND DISHWASH EXHAUST HORIZONTAL DUCT RUNS SHALL BE PITCHED A MINIMUM 1/4" PER FOOT BACK TO THE RESPECTIVE HOOD (TYPICAL) IN COMPLIANCE WITH IMC 2006 506.3.9, PROVIDE CLEANOUTS FOR HORIZONTAL DUCT RUNS SPACED NOT MORE THAN 20' -0" APART (TYPICAL) 19/12 -II II- 12/12 III IR20/20 HOOD -1 SINGLE LINE EXHAUST RISER DIAGRAM . COORDINATE THE PLACEMENT OF ENCLOSURE ACCESS � DOORS WITH TYPE 1 GREASE DUCT CLEANOUTS (TYPICAL) TENANT SHALL PROVIDE DUCT SHAFT ENCLOSURE FOR EXHAUST DUCTS. COORDINATE MTh 2ND FLOOR TENANT ®.. �1 ►:`:- ,..cwr.r�wrr..�aar� =� - A: )t �.w�.,....�a:�....r......_ ... rr:w.•� .. ��,,..� ._ —:.: x: .........:..,,.,...:..,.:::..,. ALL EXHAUST FAN, MAKEUP AIR FAN, AND ROOFTOP UNIT CURBS SHALL BE SET AND SHIMMED LEVEL BY THE GENERAL CONTRACTOR. ALL SUPPLY, RETURN, AND RESTROOM EXHAUST DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE UNDER THE ROOF STRUCTURE. COORDINATE THE INSTALLATION LOCATION OF WALL MOUNTED TEMPERATURE SENSORS TO AVOID PROXIMITY WITH HEAT PRODUCING EQUIPMENT. REFER TO THE KITCHEN EQUIPMENT DRAWINGS FOR THE MANUFACTURER'S PREPARED INFORMATION PERTAINING TO THE KITCHEN EXHAUST HOODS AND FANS. ALL GREASE EXHAUST DUCTS SHALL BE NFPA 96 APPROVED (16 GA. WELDED BLACK IRON), EXTERNALLY WELDED WITH LIQUID TIGHT JOINTS, SEAMS, AND SMOOTH RADIUS ELBOWS AND TRANSTFIONS. 6. THE CONDENSATE EXHAUST DUCT SHALL BE CORROSION RESISTANT 20 GA. ALUMINUM, EXTERNALLY WELDED WITH LIQUID TIGHT JOINTS, SEAMS, AND SMOOTH RADIUS ELBOWS AND TRANSITIONS. PROVIDE HEAT RESISTANT SIUCONE CAULKING AT EQUIPMENT CONNECTIONS FOR WATER TIGHT INSTALLATION. 7. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. ALL JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED BY APPROVED METHODS. 8. FLEXIBLE DUCT TO BE INSTALLED IN CONCEALED SPACES ONLY. THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5' -0 . ALL FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND FITTINGS WITH A PANDUIT —TYPE BAND, AND SHALL NOT BE ATTACHED DIRECTLY TO THE DIFFUSER COLLAR. 9. ALL SUPPLY DIFFUSERS SHALL BE BALANCED WITH DAMPERS AT MAIN TAKEOFF FITTING UNLESS NOTED OTHERWISE. 1 ROUTE SUPPLY AND RETURN DUCTWORK FULL SIZE FROM THE RTU CONNECTIONS THROUGH THE ROOF AS SHOWN. 1 N.L/ PROVIDE FLEXIBLE CONNECTIONS AND TRANSITION THROUGH THE JOISTS AS REQUIRED. FACTORY SUPPLIED / FIELD INSTALLED SMOKE DETECTOR CAPABLE OF SHUTTING DOWN THE RESPECTIVE MECHANICAL UNIT UPON ACTIVATION. 3 R R AIR DU T OU ' R OTE ZO P • TIRE SEN OR WIR 1 : CK TO 'ES EC •RO 3 THERMOSTAT IN MGR'S OFFICE. 4 WALL MOUNTED REMOTE ZONE TEMPERATURE SENSOR WIRED BACK TO RESPECTIVE PROGRAMMABLE THERMOSTAT IN MGR'S OFFICE COORDINATE PLACEMENT WITH KITCHEN EQUIPMENT AND ARCHITECTURAL DRAWINGS. PROGRAMMABLE THERMOSTATS IN MANAGER'S OFFICE TO BE VERTICALLY STACKED AND CLEARLY LABELED. VERIFY 5 PLACEMENT WITH ARCHITECTURAL FLOOR PLAN AND INTERIOR ELEVATIONS. 6 6 FIRE SUPPRESSION CABINET TO BE FURNISHED WITH THE HOOD PACKAGE, AND INSTALLED BY THE KITCHEN EQUIPMENT CONTRACTOR. 7 TRANSITION GREASE EXHAUST DUCT UP FROM HOOD COLLAR THRU MECHANICAL SHAFT TO 2ND FLOOR ROOF 7 MOUNTED EXHAUST FAN. GREASE EXHAUST DUCT SHALL BE OF THE SAME SIZE AS THE HOOD COLLAR. FIELD VERIFY ANY REQUIRED TRANSITIONS OR OFFSETS OF EXHAUST DUCT FROM COMBUSTIBLE MATERIALS TO MAINTAIN THE MINIMUM CLEARANCES REQUIRED PER APPLICABLE CODE(S) AND FIRE WRAP MANUFACTURER'S INSTRUCTIONS. S 8 TRANSITION CONDENSATE EXHAUST DUCT HORIZONTALLY AND EXTEND UP THRU MECHANICAL SHAFT TO 2ND FLOOR ROOF MOUNTED EXHAUST FAN. CONDENSATE EXHAUST DUCT SHALL BE OF THE SAME SIZE AS THE HOOD COLLAR. FIELD VERIFY ANY REQUIRED TRANSITIONS OR OFFSETS OF EXHAUST DUCT FROM STRUCTURE. 9 ROUTE MAKEUP AIR DUCTWORK FULL SIZE FROM THE UNIT CONNECTION THROUGH THE ROOF AS SHOWN. PROVIDE 9 FLEXIBLE CONNECTION AND TRANSITION THROUGH THE JOISTS AS REQUIRED. 10 ROUTE MAKEUP NR DUCTWORK TO PERFORATED SUPPLY PLENUM COLLAR CONNECTION. MAKEUP AIR DUCT CONNECTION SHALL BE OF THE SAME SIZE AS THE - LENUM COLLAR. 11 PROVIDE SUPPLY AIR DUCT MOUNTED SMOKE DETECTOR. COORDINATE UNE VOLTAGE POWER REQUIREMENTS AND INTERLOCK OPERATION CONTROLS OF THE MAKEUP AIR UNIT WFIH THE ELECTRICAL CONTRACTOR. 1 COMBINE THE 10 '9i RESTROOM EXHAUST DUCTS UP TO 10/12 RISER. EXTEND RISER UP TO ROOF MOUNTED EXHAUST FAN AS SHOWN. 0 , NOT USED. e AIR DEVICE IN GYPBOARD CEILING SHALL HAVE INTEGRAL VOLUME DAMPER FOR MANUAL ADJUSTMENT. 15 PROVIDE TRANSFER AIR DUCT BETWEEN RETURN AIR GRILLES AS SHOWN. 16 LOCATION OF MANUAL PULL STATION FOR KITCHEN HOOD FIRE SUPPRESSION SYSTEM ACTIVATION AND GAS SUPPLY SHUT —OFF. INSTALLATION BY OTHERS. 17 NOT USED. 18 PROVIDE CEILING MOUNTED CABINET TYPE TRANSFER AIR FAN. CONNECT 6 DISCHARGE DUCT AND TRANSF(ION TO 10x6 AIR DEVICE NECK SIZE AS SHOWN. LOUVERED DOOR SHALL BE PROVIDED BY OTHERS. RETURN AIR PLENUM SHALL BE INTERNALLY LINED AS DESCRIBED IN THE GENERAL NOTES ON SHEET M2.0. 1 BOTTOM OF RETURN PLENUM SHALL BE EVEN WITH THE BOTTOM OF THE ADJACENT SUPPLY MAIN(S). 20 RETURN AIR INTAKE OPENING SHALL HAVE A MINIMUM FREE AREA OF 12 SQUARE FEET. PROVIDE 1/4 "x1/4" CORROSION RESISTANT WIRE MESH SCREEN OVER INTAKE 21 PROVIDE A WALL MOUNTED REVERSE ACTING THERMOSTAT FOR ACTIVATION OF THE TRANSFER AIR FAN. THERMOSTAT SHALL BE SET TO ENERGIZE THE FAN UPON SENSIBLE ROOM TEMPERATURE OF 80'F. COORDINATE REQUIREMENTS WITH THE A/V EQUIPMENT. d . ?2; ` M MECHANICAL FLOOR PLAN SCALE: 1/4 ° =I' 0' / c. L 1108-0.),1 "Y/ / 1 • „, Cdr . - ; FEB 2 6 2008 PERMI r Carter Burgess CARTER & BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, #800 DALLAS, TEXAS 75247 -4925 L EXPIRES: 04-07-2008 0222.2008 w C (7) qd- 0 Lu co LLI := 4:i! 0 ,1 co CO c 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 INLINE C&B JOB NUMBER: 024203.014 DATE ISSUED: 01 -25 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT REVISIONS: A\ CITY MECH CMNTS 02/22/08 SHEET CONTENTS: MECHANICAL FLOOR PLAN SHEET NUMBER: M 1. 0 11 /30/07 01 /25/08 PACKAGED ROOFTOP UNIT SCHEDULE GENERAL MARK RTU -1 RTU -2 RTU -3 DESCRIPTION SERVING KITCHEN DINING DINING CEILING DIFFUSER - SUPPLY MANUFACTURER LENNOX LENNOX LENNOX 1459 MODEL NO. TGA240H2B TGA240H2B TGA240H2B ROOF UPBLAST FAN TYPE GAS /ELEC GAS /ELEC GAS /ELEC SAD OPERATING WEIGHT, LBS. 2860 2860 2860 I / LENGTH, WIDTH, HEIGHT 128 X 90 X 54 128 X 90 X 54 128 X 90 X 54 z MINIMUM EER 10.8 10.8 10.8 0.75 460/3 CR CEILING REGISTER BELOW DUCT - RETURN ; 7 ; %. ELECTRICAL VOLTS/ PH/ HZ 460/3/60 460/3/60 460/3/60 . _ ..... _ MIN. CIRCUIT AMP. (MCA) 55 55 55 [, ] MAX. OVERCURRENT PROT. (MOP) 60 60 60 z INDOOR BLOWER MOTOR (HP) 7.5 7.5 7.5 GREENHECK GB -091 CE CEILING REGISTER BELOW DUCT - EXHAUST 1/1 TF -1 SUPPLY FAN SUPPLY AIR CFM 8000 8000 8000 RISER - EXHAUST AIR DUCT OUTSIDE AIR CFM 2400 2400 2400 7 EXTERNAL STATIC PRESSURE IN W.G. 0.8 0.8 0.8 998 FAN RPM -- -- - VD MANUAL VOLUME DAMPER 1,3,6,8 - MAY APPLY) 4. PROVIDE GRAVITY BACKDRAFT DAMPER. SWITCH BETWEEN KITCHEN HOOD EXHAUST AND MAU -1. REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 5. PROVIDE FACTORY AVAILABLE GREASE BOX. WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE 6. FURNISHED WITH KITCHEN HOOD PACKAGE, INSTALLED BY MECHANICAL CONTRACTOR. COORDINATE REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 7. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROOF DISCONNECT SWITCH AND INTERNAL WIRING SHALL BE FACTORY INSTALLED. 8. HEATING INPUT/ OUTPUT (MBH) = 539.1/495.9 EC COOLING NOMINAL SIZE TONS 20 20 20 NEW DUCT TOTAL CAPACITY MBTUH 248 248 248 SENSIBLE CAPACITY MBTUH 184 184 184 CFIA OUTSIDE AIR DB /WB, DEG. F. 100 100 100 PROGRAMMABLE THERMOSTAT ENTERING AIR DB /WB DEG. F. 80/67 80/67 80/67 REMOTE TEMPERATURE SENSOR SD SMOKE DETECTOR ONI1N3H TYPE OF HEAT GAS GAS GAS HEATING OUTPUT MBTUH 384 384 384 HEATING INPUT MBTUH 480 480 480 OUTSIDE AIR DB, DEG. F. 6 6 6 LEAVING AIR DB, DEG. F. 97.9 97.9 97.9 S310N • ' 10 1,2,4,5,6,7$ 1,2,4,5,6,7, 1,10 NOTES- VIDE A BOTTOM NTRY SINGLE ' 01 T ELEC ' AND INSTALLED BY THE E.C. CONVENIENCE AND POWERED SEPARATELY FROM THE UNIT. A SEISMICALLY BRACED VIBRATION ISOLATION ROOF SLOPE SUCH THAT THE TOP OF THE CONTRACTOR. A SEISMICALLY BRACED FACTORY AVAILABLE THAT THE TOP OF THE CURB SETS LEVEL FACTORY INSTALL td RETURN IR SMOKE ACTIVATION. ICAL CONNE 110 . EL CTRICAL DISCONN CT SHALL BE RECEPTACLE SHALL BE FIELD INSTALLED BY THE FACTORY AVAILABLE ROOF CURB THAT ACCOMMODATES CURB SETS LEVEL. ROOF CURBS TO BE INSTALLED ROOF CURB THAT ACCOMMODATES A PITCHED ROOF ROOF CURBS TO BE INSTALLED BY THE GENERAL CONTRACTOR. DETECTOR, CAPABLE OF SHUTTING DOWN THE ROOFTOP 24/7 THERMOSTAT AND REMOTE TEMPERATURE SENSOR SECTION, BAROMETRIC RELIEF, AND CONTROLS. DAMPER SHALL BE IN FULL CLOSED POSITION DURING POSITION (SET 0/A PER SCHEDULE) DURING OCCUPIED ROOFCURBS, THERMOSTATS, AND SPECIFIED OPTIONS SHALL CONTRACTOR UNO . VERTICAL VENT EXTENSION KIT FOR MINIMUM 3' RTU OUTDOOR AIR INTAKE. . . N. N. : . N. N. ♦ N. . N. t N. C PS AS AV.ILABLE BY TH R A UFAC RE'. AND ATTACHED ON THE INSIDE OF THE RTU PRIOR RAIL SHALL THEN BE ATTACHED TO HOLD DOWN CUP INSTAL '110 I S 'UC ON . 1. PR FURNISHED E.C. 2. PROVIDE PITCHED GENERAL 3. PROVIDE SUCH 4. PROVIDE UPON 5. COOLING 6. PROVIDE CAPABLE 7. PROVIDE 8. PROVIDE SETBACK 9. THE FURNISHED 10. PROVIDE OFFSET ti - 1 . PROVID CUPS TO �N A BY THE SLOPE UNIT NIGHT HOURS. BE - 0 VERTICAL N. N. . .. LOADS LISTED ARE AT A.R.I. STANDARD. WITH MANUFACTURER'S PROGRAMMABLE OF AUTOMATIC COOLING/ HEATING CHANGEOVER. WITH FACTORY INSTALLED ECONOMIZER A 2- POSITION MOTORIZED 0/A DAMPER. HOURS. DAMPER SHALL BE IN FULL OPEN ROOFTOP UNIT PACKAGE INCLUDING RTU'S, AND INSTALLED BY THE MECHANICAL MANUFACTURER AVAILABLE/ FIELD INSTALLED OF EXHAUST FLUE GASES FROM ADJACENT ♦ ti ti 1 ♦ . . • ` ♦ ♦ S'ECIAL S IS IC '11J/ C RB 11 -DO SHALL BE SET ON TOP RAIL OF ROOF CURB, THE INSTALLATION OF THE UNIT. UNIT BASE BUT ID OF RTU. REFER TO MA UF CTURE -Nts) EXHAUST FAN SCHEDULE MECHANICAL LEGEND CFM SYMBOL RPM ABBR. DESCRIPTION MANUFACTURER MODEL TYPE CD CEILING DIFFUSER - SUPPLY a REAR PREP & PIZZA 4954 2.5 1459 CD CEILING DIFFUSER BELOW DUCT - SUPPLY GREENHECK CUBE- 300XP -50 ROOF UPBLAST FAN 84 1,3,5,6 EF -2 LEFT AND RIGHT SAD RISER - SUPPLY AIR DUCT ogp 3.0 460/3 I / CUBE- 200HP -30 SAD DROP -- SUPPLY AIR DUCT 1,3,5,6 z S/S CONDENSATE CR CEILING REGISTER - RETURN I 0.75 460/3 CR CEILING REGISTER BELOW DUCT - RETURN ; 7 ; %. 1,3,5,6 EF-4 BREWERY / EMP. RESTROOM 400 0.75 RAD RISER - RETURN AIR DUCT 460/3 GREENHECK GB -091 -4 [, ] 58 RAD DROP - RETURN AIR DUCT PUBLIC RESTROOM z 0.5 CE CEIUNG REGISTER - EXHAUST 115/1 GREENHECK GB -091 CE CEILING REGISTER BELOW DUCT - EXHAUST 1/1 TF -1 A/V ROOM 100 0.25 950 EAD RISER - EXHAUST AIR DUCT GREENHECK SP --B110 CEILING CABINET FAN 10 7 (L) LINED DUCTWORK t._,_=.._ _ 0.5 998 5 460/3 . DGX- 115 -H22 VD MANUAL VOLUME DAMPER 1,3,6,8 - MAY APPLY) 4. PROVIDE GRAVITY BACKDRAFT DAMPER. SWITCH BETWEEN KITCHEN HOOD EXHAUST AND MAU -1. REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 5. PROVIDE FACTORY AVAILABLE GREASE BOX. WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE 6. FURNISHED WITH KITCHEN HOOD PACKAGE, INSTALLED BY MECHANICAL CONTRACTOR. COORDINATE REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 7. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROOF DISCONNECT SWITCH AND INTERNAL WIRING SHALL BE FACTORY INSTALLED. 8. HEATING INPUT/ OUTPUT (MBH) = 539.1/495.9 EC FLEXIBLE CONNECTION NOTES: (NOT ALL MAY APPLY) 3. AIR DEVICE SHALL BE OF ALUMINUM CONSTRUCTION. MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED. 4. PROVIDE SEISMIC BRACING AS REQUIRED. IN THE DINING AREA SHALL HAVE MANUFACTURER APPLIED 5. 4' -0" LONG LINEAR SWT DIFFUSER, 2 -SWT, WITH SUITABLE FOR FINAL PAINT FINISH (BY OTHERS). REFER TO END CAPS, END BORDERS AND MODEL MPI39 DRAWINGS FOR COORDINATION. MODUUNEAR DIFFUSER PLENUM. 1. PROVIDE NECESSARY 2. ALL AIR DEVICES PRIMER FINISH ARCHITECTURAL NEW DUCT ® AIR DEVICE DESIGNATION CFIA TD TSTAT PROGRAMMABLE THERMOSTAT SQ SENS REMOTE TEMPERATURE SENSOR SD SMOKE DETECTOR CFM CUBIC FEET PER MINUTE S/A SUPPLY AIR 0/A OUTSIDE AIR E/A EXHAUST AIR S.P. STATIC PRESSURE -Nts) EXHAUST FAN SCHEDULE I MARK SERVICE CFM E S. RPM MOTOR VOPHS/ MANUFACTURER MODEL TYPE WEIGHT NOTES y EF -1 ' REAR PREP & PIZZA 4954 2.5 1459 5.0 460/3 GREENHECK CUBE- 300XP -50 ROOF UPBLAST FAN 84 1,3,5,6 EF -2 LEFT AND RIGHT 4472 1.75 1500 3.0 460/3 GREENHECK CUBE- 200HP -30 ROOF UPBLAST FAN 142 1,3,5,6 9 EF -3 S/S CONDENSATE 1800 1.0 1414 0.75 460/3 GREENHECK GB -141 -7 ROOF UPBLAST FAN 83 1,3,5,6 EF-4 BREWERY / EMP. RESTROOM 400 0.75 1424 0.25 460/3 GREENHECK GB -091 -4 ROOF UPBLAST FAN 58 1,3,5,6 EF -5 PUBLIC RESTROOM 600 0.5 1251 0.25 115/1 GREENHECK GB -091 ROOF DOWNBLAST FAN 58 2,4,7 TF -1 A/V ROOM 100 0.25 950 80W 115/1 GREENHECK SP --B110 CEILING CABINET FAN 10 7 MAU -1 KITCHEN HOODS 6600 0.5 998 5 460/3 GREENHECK DGX- 115 -H22 ROOF SUPPLY FAN 1205 1,3,6,8 NOTES: (NOT ALL MAY APPLY) 4. PROVIDE GRAVITY BACKDRAFT DAMPER. SWITCH BETWEEN KITCHEN HOOD EXHAUST AND MAU -1. REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 5. PROVIDE FACTORY AVAILABLE GREASE BOX. WEATHER PROOF DISCONNECT SWITCH IN SIGHT OF THE 6. FURNISHED WITH KITCHEN HOOD PACKAGE, INSTALLED BY MECHANICAL CONTRACTOR. COORDINATE REQUIRED WORK WITH THE ELECTRICAL CONTRACTOR. 7. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROOF DISCONNECT SWITCH AND INTERNAL WIRING SHALL BE FACTORY INSTALLED. 8. HEATING INPUT/ OUTPUT (MBH) = 539.1/495.9 1. PROVIDE INTERLOCK COORDINATE 2. PROVIDE INDEPENDENT EQUIPMENT. 3. WEATHER AIR DEVICE SCHEDULE MARK FACE SIZE TYPE MOUNTING TYPE MAXIMUM N.C. DIRECTION MANUFACTURER MODEL NOTES CD 12x12 SUPPLY SURFACE 30 4-WAY TITUS OMNI -AA 1,2,3,4 TD 24x24 SUPPLY SURFACE 30 4 -WAY ACUTHERM TF-HC 1,2,3,4 KD 24x24 SUPPLY LAY -IN 30 1 -WAY TITUS PAS -AA 1,2,3,4 RD VARIES SUPPLY DUCT 30 RADIAL TITUS TMRA -AA 1,2,3,4 SD 60x3.5 SUPPLY SURFACE 30 1-WAY TITUS CT -541 1,2,3,4 CR 24x24 RETURN LAY -IN 30 1 -WAY TITUS PAR -AA 1,2,3,4 CE 12x12 EXHAUST SURFACE 30 1 -WAY TITUS 350FL 1,2,3,4 SR 12x8 TRANSFER SURFACE 30 1 -WAY TITUS 4FL 1,2,3,4 DL 20x10 SUPPLY SURFACE 30 1--WAY TITUS DL 1,2,3,4 LD 48x4 SUPPLY SURFACE 30 2 -WAY TITUS ML -39 1,2,3,4,5 NOTES: (NOT ALL MAY APPLY) 3. AIR DEVICE SHALL BE OF ALUMINUM CONSTRUCTION. MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED. 4. PROVIDE SEISMIC BRACING AS REQUIRED. IN THE DINING AREA SHALL HAVE MANUFACTURER APPLIED 5. 4' -0" LONG LINEAR SWT DIFFUSER, 2 -SWT, WITH SUITABLE FOR FINAL PAINT FINISH (BY OTHERS). REFER TO END CAPS, END BORDERS AND MODEL MPI39 DRAWINGS FOR COORDINATION. MODUUNEAR DIFFUSER PLENUM. 1. PROVIDE NECESSARY 2. ALL AIR DEVICES PRIMER FINISH ARCHITECTURAL AIR BALANCE SCHEDULE MARK DINING KITCHEN S/A 0/A E/A S/A 0/A E/A RTU -1 - - -- 8000 2400 - RTU -2 8000 2400 - - - - RTU -3 8000 2400 -- - - - EF-1 - - - - - 4954 EF -2 - - - -- - 4472 EF -3 - - - - - 1800 EF -4 - - - - - 400 EF -5 - - 600 - - - MAU-1 - - - - 6600 - TOTAL 16000 4800 600 8000 9000 11626 DINING PRESSURIZATION KITCHEN PRESSURIZATION (0 /A) - (E /A)= 4200 (0 /A) - (E /A)= -2626 NET BUILDING PRESSURIZATION (DINING + KITCHEN)= 1574 0/A VENTILATION SCHEDULE AREA SERVED # OF PEOPLE CFM /PERSON CFM SQ. FEE DINING 5213 253 20 5060 KITCHEN - 20 15 300 TOTAL 0/A REQUIRED 5360 NOTES: ARE BASED ON 2006 IMC, TABLE 403.3 AIR DEMAND IS: 5360 CFM AIR PROVIDED IS: 7200 CFM THE AIR BALANCEDULE FOR ADDITION I�( 110N 1. CALCULATIONS 2. OUTDOOR OUTDOOR 0 w ca c 22 CONDENSATE V 1 22• FLEXIBLE DUCT CONNECTION (TYP) RETURN AIR DUCT e W o o Qw ROOF ANGLE COLLAR AROUND OPENING (TYP) SEAL DUCT CONNECTION (TYP) VOID SPACE BETWztN BUILDINGS ROOFTOP UNIT n HINGED HOOD FOR SERVICE ACCESS, SHOWN IN THE CLOSED POSITION 'PROVIDE FIELD FABRICATED 16 GA. GALVANIZED TRANSITION FUNNEL WITH LIQUID TIGHT SEAMS AND FULLY WELDED MITERED CORNERS RATED ENCLOSURE SHALL BE (1) LAYER OF FAST WRAP+ 1 -1/2" THICK THERMAL CERAMICS FIREMASTER GREASE EXHAUST DUCT WRAP (AS ALLOWED BY THE JURISDICTION HAVING AUTHORITY) ROOFTOP UNIT DETAIL SCALE: NOT TO SCALE ATTACH DIFFUSER BOOT TO TRUNK DUCT WITH POP RIVETS OR SHEETMETAL SCREWS SCALE NOT TO SCALE GREASE TRAP 3/8" LAG SCREW 12" ON CENTER, MINIMUM 2 PER SIDE. PREFABRICATED ROOF 14" HIGH FACTORY CURB SCALE NOT TO SCALE CONDENSER COIL GAS SERVICE (WHERE SHOWN ON THE DRAWINGS) SUPPLY AIR DUCT -1 SCALE: NOT TO SCALE PROVIDE RECTANGULAR TO ROUND TRANSITION ELECTRICAL DISCONNECT DO NOT INSTALL OVER UNIT - LABELS OR 1 COILS. - POWER AND CONTROL SERVICES. FACTORY CURB WITH CANT STRIP, COUNTER FLASHING, AND GASKET. ROOF DECK UNDER UNIT TO REMAIN FOR SOUND CONTROL EXCEPT AT DUCT PENETRATION. SUPPLY DUCT RISER SHALL BE FULL SIZE OF RTU CONNECTION PROVIDE SMACNA APPROVED RECTANGULAR PAIR OF PANTS TRANSITION FOR EQUAL SPLIT INTERNALLY LINED RIGID ROUND SUPPLY DUCT. HOLD TIGHT TO BOTTOM OF CLG /ROOF STRUCTURE SEAL BOOT CONNECTION AIRTIGHT INSULATE BOOT WITH 1" DUCTLINER PROVIDE AIR BALANCING DEVICE SIMILAR TO TITUS AG -15-HD DRUM LOUVER OPPOSED BLADE DAMPER AIR DEVICE SHALL BE DRUM LOUVER WITH ROTATING BODY AND ADJUSTABLE VANES SHEETMETAL OUTLET BOOT SHALL BE FABRICATED SAME SIZE AS AIR DEVICE FRAME. HOLD DEPTH OFF SUPPLY DUCT TO MINIMUM EXPOSED SUPPLY DUCT DETAIL NOTE INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 96 REQUIREMENTS. UPBLAST VERTICAL DISCHARGE U.L LISTED GREASE EXHAUST FAN NEMA 3R DISCONNECT FACTORY WIRED TO MOTOR FIELD WIRING IN LIQUID TIGHT FLEXIBLE CONDUIT (TYPICAL) (ALLOW SUFFICIENT CONDUIT FOR UNIT TO HINGE -UP FOR CLEANING.) VENTILATED ROOFCURB EXTENSION (OR TALL CURB) RESIUENT GASKET FLASH AND COUNTERFLASH ROOF CURB ROOF ASSEMBLY DETAIL SEISMIC JOINT DETAIL EXTEND GREASE DUCT UP THROUGH ROOF CURB TO TRANSITION FUNNEL GREASE EXHAUST DUCT. MINIMUM 16 GAUGE STEEL WELDED LIQUID TIGHT. ROOF MOUNTED GREASE EXHAUST FAN DETAIL NOTE: DETAIL SHOWN IS ADAPTED FROM SHEET M6.0 -2/ DETAIL #8 AS DEVELOPED BY CDIENGINEERS AND MADE AVAILABLE BY WESTFIELD DESIGN AND CONSTRUCTION BUILDING WALL (TYP) DUCTWORK, SEE PLANS FOR SIZES AND LOCATIONS • FLEXIBLE CONNECTION, SIZE TO ALLOW FOR 4" BUILDING MOVEMENT (TYP) STUFF ANNULAR SPACE WITH ROCK WOOL FACTORY ROOF CURB fr r 9 FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5' -0" -- SUPPLY AIR DIFFUSER WITH R SHEET METAL RISER FULL SIZE OF FAN OPENING TRANSITION SUPPORT DUCT RISER WITH ALL THREAD SUPPORT RODS M2.0 1 SCALE NOT TO SCALE COORDINATE WITH LANDLORD REQUIREMENTS. ALL REQUIRED SEISMIC BRACING AND RESTRAINTS NOT SHOWN SHALL BE INCLUDED. 11E OFF TO ROOF STRUCTURE INSULATED SHEETMETAL METAL BAND SUPPLY DUCT. SEALED SUPPORT PER SPECIFICATIONS. NYLON DRAW BAND (TYP) ROUND NECK T--BAR TYPE /GYP SUSPENDED CEILING i _L 2 CEILING MNTD. SUPPLY AIR DIFFUSER DETAIL SCALE: NOT TO SCALE � 4 RESTROOM EXHAUST FAN DETAIL NOTES: 1.) CONTRACTOR SHALL PROVIDE ALL FLASHING, COUNTERFLASHING, AND ANY OTHER MATERIALS AND LABOR NECESSARY TO ENSURE A WATERTIGHT ROOF PENETRATION ENCLOSURE. 2.) ALL ROOFING WORK TO BE PERFORMED BY THE MAll ROOFING CONTRACTOR. 3.) CONTRACTOR SHALL COORDINATE EXACT LOCATION OF ROOFTOP EQUIPMENT WITH THE BUILDING STRUCTURAL ENGINEER AND OBTAIN APPROVAL PRIOR TO COMMENCING WORK. AC UNIT ROOF CURB DETAIL SCALE: NOT TO SCALE INSULATION PINS ALUMINUM TAPE AT EDGES (TYP) PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK SPEED CUPS SPOOL PIECES FOR THREADED RODS SCALE NOT TO SCALE RIGID ROUND DUCT JOINT SCREWED & SEALED ROOFTOP EXHAUST FAN RE ARCHITECTURAL FOR ROOFING DETAILS ROOF DECK GRAVITY BACKDRAFT DAMPER SHEET METAL EXHAUST DUCT RISER. RE: PLANS FOR SIZE L C JUNG AC UNIT SPRING ISOLATOR NAILER Y �- COUNTER FLASHING I � FLASHING CANT. STRIP. � ` THREE -PLY MEMBRANE METAL DECK NOTE ACCESS DOORS TO BE LOCATED AT MAXIMUM 10' -0" 0.C. AND AT EACH CHANGE IN DIRECTION IN BOTH HORIZONTAL AND VERTICAL DUCT RUNS. GREASE DUCT EXISTING ROOFING ASSEMBLY 1FLR TO STRUCTURAL DRAWINGS FOR ANGLES TO FRAME UNDER CURB AND DUCT PENETRATIONS. DOOR OPENING 1/4" ALL THREAD RODS 16 GA. ACCESS COVER GREASE DUCT ACCESS DOOR SINGLE LAYER FIREMASTER FASTWRAP+ 1" OVERLAP SINGLE LAYER F1REMASTER FASTWRAP+ 1 1/2" 1/4" WING NUTS N1atI4.tw is be httgvt.k4 wh, W4* k..1 aYwsY htdP 44 IlMIib4 1.,..iy resp4 bci Ma 4 is. /11t Nets sit *Ay f► dw4 R MAO .9 aWsiVRhiAn '4t -4. 1 kNJ Mis* wW NkMMw ivw+k• wkt�w cooWw9 epeA*iM new b,) SGNtos w 'prom' me$44w1. 3" MIN. LONGINTUDINAL OVERLAP GREASE DUCT 1/2" WIDE (MIN.) STEEL BANDING AND FILAMENT TAPE (TYP) SCALE NOT TO SCALE 1 LAYER FIREMASTER FASTWRAP+ 1 1/2" 3/8 "5 MIN. HANGER RODS 1/2 x 1/2 x 1/8 SUPPORT ANGLE (IF REQUIRED) NOTE: CONTRACTOR TO INSTALL DUCTWRAP WITH STRICT ACCORDANCE TO MANUFACTURER'S REQUIREMENTS. GREASE DUCT WRAP (UL LISTED) CODE CC M LI AN • a City t..:' f.'ijkAJ f L Jy ' 7 .. -. , MO8 0 1. NOTE: FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL OF THE CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING ANY MATERIALS. 2. THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR THE COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. 3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ADMINISTERING ALL WARRANTIES ON EQUIPMENT WHICH THEY FURNISH AND INSTALL. 4. PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND /OR LABOR, AT NO COST TO OWNER, FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. PROVIDE 5 YEAR COMPRESSOR WARRANTY FOR AC UNITS. WARRANTIES SHALL BEGIN ON THE DATE OF SUBSTANTIAL COMPLETION. 5. ALL OUTDOOR AIR INTAKE BY MECHANICAL EQUIPMENT SHALL HAVE A MINIMUM 1O' -0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY EXHAUST FAN, RTU GAS EXHAUST OR PLUMBING VENT. 6. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED. 7. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 8. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES AS REQUIRED FOR A COMPLETE INSTALLATION. 9. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND OTHER TRADES ALL REQUIRED OPENINGS AND PENETRATIONS. ALL REQUIRED OPENINGS IN FOUNDATIONS, FLOORS, WALLS AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE WITH THE USE OF SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A MINIMUM. 10. ALL ITEMS PROJECTING THROUGH THE ROOF SHALL BE FLASHED THROUGH CURBS OR PIPE SEALS A MINIMUM OF 12" ABOVE THE ROOF. THE PIPE CURBS AND SEALS SHALL BE INSTALLED BY THE ROOFING CONTRACTOR. ENSURE THAT AMPLE BOOT OPENINGS ARE PROVIDED TO ACCOMMODATE ANY ELECTRICAL CONDUIT PENETRATIONS REQUIRED FOR POWER. 11. COORDINATE THE INSTALLATION AND FINISH OF ALL SUPPLY AND RETURN AIR DEVICES. AIR DEVICES LOCATED IN GUEST AREAS (INCLUDING DINING AND BAR) SHALL BE PAINTED PER THE ARCHITECTURAL DRAWINGS FINISH SCHEDULE. 12. THERMOSTATS AND REMOTE SENSORS SHALL BE LOCATED AT 54" A.F.F. EXACT LOCATIONS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL- MOUNTED WORK. 13. THERMOSTATS SHALL BE RTU MANUFACTURER AVAILABLE 24/7 AUTOMATIC CHANGEOVER TYPE TO SEQUENCE HEATING AND COOLING. SET POINT RANGE SHALL BE 10'F BETWEEN FULL HEATING AND FULL COOLING. ADJUSTABLE TEMPERATURE DIFFERENTIAL SHALL BE 1- 1/2'F. THERMOSTAT CONTROL RANGE SHALL BE 55'F TO 85'F. CONTROLS SHALL HAVE CAPABILITY OF TERMINATING HEATING AT NO HIGHER THAN 70'F AND COOLING AT NO LOWER THAN 75F. 14. PROVIDE INTERLOCKING CONNECTION BETWEEN ALL AC UNITS/ SUPPLY FANS AND EXHAUST FANS (INCLUDING RESTROOM FANS). WHEN EXHAUST SYSTEM IS ON, AC UNITS SHALL BE ENERGIZED. THIS PROCESS ENSURES BALANCING OF SUPPLY AIR AND EXHAUST AIR PER CODE. REFER TO ELECTRICAL DRAWINGS FOR SCHEMATIC. 15. ROOFTOP UNITS SHALL BE SET TO RUN IN "FAN CONTINUOUS" MODE DURING OCCUPIED HOURS. DURING NIGHT SET -BACK HOURS, THE ROOFTOP UNITS SHALL RUN IN "FAN AUTO" MODE. CONTRACTOR SHALL COORDINATE NECESSARY CONTROL WIRING REQUIREMENTS WITH THE MANUFACTURER TO ACCOMPLISH THIS CONTROL SEQUENCE WITHOUT THE USE OF A MANUAL SWITCH ON THE SUB-BASE. 16. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL 4" HIGH BLACK OVER WHITE LAMINATE NAMEPLATE WITH 2" LE 11E1.6 VISIBLE ADJACENT TO DISCONNECT SWITCH FOR ROOFTOP UNITS AND ROOF MOUNTED FANS. 17. LINE VOLTAGE WIRING, ALL CONDUIT DISCONNECT SWITCHES AND FINAL CONNECTION BY ELECTRICAL CONTRACTOR. LOW VOLTAGE CONDUIT AND WIRING AND FINAL CONNECTION BY MECHANICAL CONTRACTOR. 18. ALL HVAC SUPPLY AND RETURN EXPOSED DUCTWORK SHALL BE INTERNALLY LINED WITH MINIMUM R - 5.0, 1 - 1/2' INSULATION WITH VAPOR BARRIER PER THE 2006 INTERNATIONAL MECHANICAL CODE. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. REFER TO ARCHITECTURAL DRAWINGS FOR DUCT PAINT OR COLOR SPECIFICATION 19. ALL HVAC SUPPLY AND RETURN CONCEALED DUCTWORK TO BE EXTERNALLY WRAPPED WITH MINIMUM R - 5.0, 2" INSULATION WITH VAPOR BARRIER PER THE 2006 INTERNATIONAL MECHANICAL CODE. INSULATION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME SPREAD, 50 SMOKE DEVELOPED. 20. SUPPLY, RETURN, RESTROOM EXHAUST, AND MAKEUP AIR DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL ANY REQUIRED GAUGES, SWAY BRACING AND SUSPENSION SHALL CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD IS NOT ALLOWED (UNO). 21. PITCH ALL HORIZONTAL GREASE AND CONDENSATE DUCTWORK UNIFORMLY BACK TOWARDS THE HOOD AT 1/4" PER FOOT (NOT TO EXCEED 50' -0 "). 22. ALL GREASE EXHAUST DUCT SHALL BE WRAPPED WITH UL LISTED FIRE WRAP (IF REQUIRED) SIMILAR TO "FIREMASTER" WRAP. IF FIREWRAP IS NOT ALLOWED, PROVIDE TWO -HOUR RATED ENCLOSURE AROUND HOOD EXHAUST DUCT. ALL GREASE EXHAUST FAN ROOF CURB SHALL BE VENTED PER NFPA 96. PROVIDE ACCESS FOR CLEANING. EITHER INSTALLATION SHALL BE IN COMPLIANCE WITH UL TESTED STANDARDS. 23. ROOF CURBS FOR EXHAUST FANS AND THE MAKEUP AIR UNIT SHALL BE FACTORY FABRICATED OF FULL WELDED STEEL CONSTRUCTION WITH WOOD NAILER, AND FURNISHED WITH THE HOOD AND FAN PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL SHIM CURBS DEAD LEVEL COORDINATE EXACT SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL_ FRAMING. CUTTING OF STRUCTURAL MEMBERS IS NOT PERMITTED. 24. ROOF CURBS FOR ROOFTOP UNITS SHALL BE FACTORY FABRICATED OF FULL WELDED STEEL CONSTRUCTION WITH WOOD NAILER, AND FURNISHED WITH THE RTU PACKAGE. VERIFY REQUIREMENTS FOR THE ROOF CURBS WITH THE EQUIPMENT SUPPLIER. THE GENERAL CONTRACTOR SHALL SHIM CURBS DEAD LEVEL. COORDINATE EXACT SIZE AND LOCATION OF ROOF OPENINGS WITH THE STRUCTURAL FRAMING. CUTTING OF STRUCTURAL MEMBERS IS NOT PERMITTED. 25. THE WALL MOUNTED CANOPY TYPE KITCHEN EXHAUST HOODS SHALL BE INSTALLED AT 6' -8" AFF (LINO). COORDINATE THE INSTALLATION AND PLACEMENT OF THE EXHAUST HOODS IN THE FIELD. 26. THE KITCHEN HOOD PACKAGE WILL BE PROVIDED WITH END CABINET(S) HOUSING THE FIRE SUPPRESSION TANKS, HOOD EXHAUST FAN SWITCHES, AND UGHT SWITCHES. 27. THE GREASE EXHAUST DUCT RISERS BETWEEN THE HOOD COLLARS AND EXHAUST FANS SHALL BE OF THE SAME SIZE AS THE RESPECTIVE HOOD COLLAR SIZE, (UNO). REFER TO THE MANUFACTURER SHEETS IN THE KITCHEN EQUIPMENT DRAWING SET FOR THE HOOD COLLAR SIZES AS PROVIDED BY THE HOOD MANUFACTURER. 28. REFER TO MANUFACTURER SHEETS FOR THE HOOD CONTROL WIRING DIAGRAM FOR OPERATION OF THE KITCHEN HOOD EQUIPMENT. 29. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND REPLACING THE AIR FILTERS AT THE ROOFTOP UNITS WITH 2" THICK MERV 7 THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. 30. ALL RETURN GRILLE AIR QUANTITIES USED ARE FOR OCCUPIED HOURS. 31. THE TOTAL SYSTEM AIR BALANCE SHALL BE PERFORMED BY AN INDEPENDENT AGENCY CERTIFIED BY THE AABC. THIS WORK SHALL CONFORM TO AABC SPECIFICATIONS AS REFERRED TO IN THE AABC NATIONAL STANDARDS. THE AIR BALANCE AGENCY SHALL BE A DIRECT SUB CONTRACTOR TO THE GENERAL CONTRACTOR. 32. PER THE 2006 INTERNATIONAL MECHANICAL CODE WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR IN EXCESS OF 2000 CUBIC FEET PER MINUTE SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY INTERRUPTING THE POWER SOURCE OF THE AIR MOVING EQUIPMENT DEVICES WHICH WILL DETECT PRODUCTS OF COMBUSTION OTHER THAN HEAT, AND WHICH COMPLY WITH THE UBC, SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR DUCT INSTALLATION AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SUCH DEVICES SHALL BE COMPATIBLE WITH THE OPERATING VELOCITIES, PRESSURES, TEMPERATURES AND HUMIDITIES OF THE SYSTEM WHERE FIRE DETECTION OR ALARM SYSTEMS ARE PROVIDED FOR THE BUILDING, SMOKE DETECTORS SHALL BE SUPERVISED BY SUCH SYSTEMS. 33. MECHANICAL CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. 34. THE ROOFING CONTRACTOR SHALL BE BONDED AND APPROVED BY THE LANDLORD. ALL ROOF PENETRATIONS, FLASHING, AND COUNTER - FLASHING SHALL BE PERFORMED BY THE ROOFING CONTRACTOR MECHANICAL GENERAL NOTES MECHANICAL SEISMIC NOTES 1. ALL ANCHORAGE AND /OR SEISMIC RESTRAINTS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. 2. APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE SECURELY FASTENED IN PLACE. THE ANCHORAGE AND/ OR SEISMIC RESTRAINTS FOR APPLIANCES SHALL BE DESIGNED AND CONSTRUCTED TO SUSTAIN VERTICAL AND HORIZONTAL LOADS WITHIN THE STRESS LIMITATIONS SPECIFIED IN THE 2006 INTERNATIONAL BUILDING CODE 3. FURNISH AND INSTALL SEISMIC BRACING BASED ON APPROPRIATE SEISMIC ZONE REQUIREMENTS PER 2006 INTERNATIONAL MECHANICAL CODE. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE DETAILS AND DESIGN COMPLETE WITH A STRUCTURAL ENGINEER'S CERTIFICATION TO BE SUBMITTED FOR PERMITTING. 4. DUCTS SUPPORTED BY A TRAPEZE, NOT INDIVIDUALLY REQUIRE BRACING, NEED NOT BE BRACED IF CONNECTIONS TO THE DUCT OR DIRECTIONAL CHANGES DO NOT RESTRICT MOVEMENT OF THE TRAPEZE. IF THIS FLEXIBILITY IS NOT PROVIDED, BRACING IS REQUIRED WHEN THE COMBINED OPERATING WEIGHT SUPPORTED BY THE TRAPEZE IS 10 LBS /FT OR GREATER. 5. SEISMIC RESTRAINTS ARE REQUIRED FOR THE FOLLOWING INSTALLATIONS: A) ALL FLOOR OR ROOF MOUNTED EQUIPMENT WEIGHING 400 LBS. OR GREATER. B) ALL SUSPENDED OR WALL MOUNTED EQUIPMENT WEIGHING 20 LBS. OR GREATER. C) ALL VIBRATION ISOLATION EQUIPMENT WEIGHING 20 LBS. OR GREATER. D) ALL VERTICALLY MOUNTED WELDED GREASE DUCTS. E) ALL TYPE 1 KITCHEN EXHAUST HOODS. I ECF cnNy ` A FEB 2 6 2008 Carter }: CARTER 3. BURGESS, INC. 1420 WEST MOCKINGBIRD LANE, #800 DALLAS, TEXAS 75247 -4925 EXPIRES: 04 -07 -2008 02.22.2008 co w 00 CC w< CL 0 uj : CO LIJ LL 0 isce CO ki co 7755 CENTER AVE STE. 300 HUNTINGTON BEACH, CA. 92647 MINE C8B JOB NUMBER: 024203.014 DATE ISSUED: 0125 -08 FOR PERMIT ISSUES: HEALTH DEPT PERMIT REVISIONS: /\CITY MECH CMNTS 02/22/08 /\CLARIFICATIONS 02/22/08 SHEET CONTENTS: SCHEDULES AND DETAILS SHEET NUMBER: M2.0 11/30/07 01/25/08