HomeMy WebLinkAboutPermit M08-022 - 9010 BUILDING9010 BUILDING 9010 EAST MARGINAL WY S M08-02 2 Parcel No.: 5422600160 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC -10/06 CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 9050 EAST MARGINAL WY S TUKW Value of Mechanical: $62,064.00 Type of Fire Protection: 9010 BUILDING 9010 EAST MARGINAL WAY S , TUKWILA WA KING COUNTY 500 K C ADMIN BLDG , SEATTLE WA Contact Person: Name: MICHELLE MULLIN Address: 7717 DETROIT AV SW , SEATTLE WA Contractor: Name: MACDONALD /MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA Contractor License No: MACDOFS980RU Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -022 Permit Number: Issue Date: Permit Expires On: Expiration Date: 12/31/2008 DESCRIPTION OF WORK: REISSUE OF EXPIRED PERMIT M07 -045. REMOVE PLUNGER STYLE DAMPERS FROM 112 FAN POWERED UNITS AND REPLACE WITH NEW VALVES AT THE INLET. RELOCATE 28 VAV'S AND MISCELLANEOUS DUCT WORK PER PLANS Phone: Phone: 206- 768 -4254 Phone: 206 - 763 -9400 M08 -022 02/08/2008 08/06/2008 Fees Collected: $665.46 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 02 -08 -2008 Permit Center Authorized Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -022 Issue Date: 02/08/2008 Permit Expires On: 08/06/2008 Date: Vb I hereby certify that I have read andlpxan ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie vent whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: Date: 02- Print Name: j YL tI A. SR-- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -022 Printed: 02 -08 -2008 Parcel No.: 5422600160 Address: 9050 EAST MARGINAL WY S TUKW Suite No: Tenant: 9010 BUILDING 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: M08 -022 Status: ISSUED Applied Date: 01/30/2008 Issue Date: 02/08/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. M08 -022 Printed: 02 -08 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: //( &tJ‘/2Z-- Print Name: doc: Cond -10/06 Date: _0S -0 M08 -022 Printed: 02 -08 -2008 r CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No, Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 5 y 2 Q. (coo 14, Q Site Address: 9 0/0 E 11/ O_f 1 ✓1 GN.4 W Suite Number: Floor: f j 2 3 Tenant Name: 9 / 0 1..A1Y' 1 ' \ New Tenant: El Yes \ q. No J Property Owners Name: I ;15 Ca„,.. � t [[,.Cfr ion s Mailing Address: 1.-A/ 14 CONTACT PERSON Name: in L-t I l l u. I l i 11 ? D�ay�Te�lephonerLl Mailing Address: — 1 —) 1 t� 1 nn k..5C S L e?rL�M ( w A PiO(. City State Zip E -Mail Address: Fax Number: GENERAL CONTRACTOR INFORMATION — (Contractor'I t echanical (pg 4) for Plumbing and Gas Piping (pg 5) ) Company Name: Mailing Address: Company Name: Mailing Address: Company Name: Mailing Address: Contact Person: Q:\Applications \Fortes- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh City Contact Person: Day Contact Person: Day Telephone. E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: stamped by Architect of Record ARCHITECT OF RECORD - All plans must be we ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record E -Mail Address: Fax Number: City E -Mail Address: Fax Number: ne: State State State State Zip Zip Zip Zip elephone: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment MECHANICAL PERMIT INFORMATION -206- 431 -3670 MECHANICAL CONTRACTOR INFORMATION . Company Name: fV\ c Q V 1, Mailing Address: ''7 r ) 1 ' 1 S Contact Person: d/ Q J. . V y\ ■ �' L E -Mail Address: Contractor Registration Number: >M A Q.,Q 0 i $ °l so Valuation of Project (contractor's bid price): $ ( p 2 t 0744, oD Scope of Work (please provide detailed information): 9.12.4/1/1 M .R it) te., er' — cot - i d L [ � O..rv, f-P,e'S 1) 2 G sr\ Q Oh.jQ.✓ C .. v` w k C cur. A fit? LkCi , r ►1Lw i 0.1v e S co 'HA -� v l A.A o c .fie Zg v A v Cw w. tS c a U c+L a ?t. f& f C c.r ■s Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement ... Fuel Type: Electric Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: Q:Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 4 -2006 bh City State Zip Day Telephone: (J5 L) Z (o — 4 a. Fax Number: Expiration Date: 1 2- -3 1 Page 4 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Signature: Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A .�1►i_ OM "D A R, L)a. - S>o 0' \ Day Telephone( tD ) 7( Mailing Address: 7 L - 1 ''S>eVr -Lo ' S L,a �.c�w v'' `\,3 ‘o City State Zip Date Application Expires: 7-- SO S. I Date Application Accepted: L Q:\Applications \Forms- Applications On Lined -2006 - Permit Application.doc Revised: 4 -2006 bh Date: I oS Staff Initials: Page 6 of 6 Receipt No.: R08 -00264 Payee: MACDONALD MILLER ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 5422600160 Permit Number: M08 -022 Address: 9050 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 01/30/2008 Applicant: 9010 BUILDING Issue Date: Initials: WER Payment Date: 01/30/2008 01:53 PM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 1583 411.28 Account Code Current Pmts 000/322.100 411.28 Total: $411.28 • Payment Amount: $411.28 7858 01/30 9710 TOTAL 411028 doc: Receiot -06 Printed: 01 -30 -2008 Projec : A . gen-A / Type of I pection: 7/ .vim / Address: ate Called: Special Instructions: Date Wanted: oz / /.� / e a,m p.m. Requester: Phone No: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 A pproved per applicable codes. INSPECTION RECORD Retain a copy with permit /fag PERMIT NO. (206)431 -367 Corrections required prior to approval. COMMENTS: ;) , /0 Pt rrh / f ( -, lF- 4' / .0/yeti I tJ3 /' $50. ' 0 REINSPECTION FE REQUIRED. Prior to inspection, fee must be d at 6300 Southcenter Btvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -022 • DATE: 01 -30 -08 PROJECT NAME: 9010 BUILDING SITE ADDRESS: 9010 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: BuiI. g +i sion Public Works Complete Documents/routing slip.doc 2 -28-02 Fire Prevention ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Comments: F er entetili e'Only • :.:•,r. .- :'' _ 'yy :- ..1. •. . 'fret '. :?H :n :,. '• ',• 'i' ..'#' ' ... Y4 .. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required Planning Division DUE DATE: 01 -31-08 Not Applicable No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02 -28 -08 Approved ❑ Approved with Conditions IZ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: u Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License MACDOFS980RU Licensee Name MACDONALD/MILLER FAC SOL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602254260 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 PO BOX 47983 Address 2 City SEATTLE County KING State WA Zip 98106 Phone 2067684180 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/31/2002 Expiration Date 12/31/2008 Suspend Date Separation Date Parent Company Previous License DIVCOI *988RC Next License Associated License Business Owner Information Name Role Effective Date Expiration Date SIGMUND, FREDRIC PRESIDENT 12/31/2002 KOPET, TYLER SECRETARY 12/31/2002 KOPET, TYLER TREASURER 12/31/2002 LOVELY, STEVE C VICE PRESIDENT 12/31/2002 Look Up a Contractor, Electan or Plumber License Detail Washington State Department of Labor and Industries General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MACDOFS980RU 02/08/2008 MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiIler.com WA Lic No: MACDOFS980RU _ - - - = - � A Sg Vii -- 4 0 - , Ct r�fFaf=='L� 36163 �w � _'. �`�' GIST :.. s - f = s "ONA ._.._: I EXPIRES: 07 -06 -08 TYPE NOTES / \ CD /PERMIT 02 -16 -07 REVISIONS: DATE AS NOTED 9010 BUILDING JAN 3 0 2008 PERMIT CENTER 9010 EAST MARGINAL WAY TUKWILA, WA 120W SCHEDULES & NOTES - HVAC ENGINEER LAST REVISED: M MULLIN 02- 16 ---07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 DRAWING NUMBER: C -1461- 7275035 -00 ISSUED FOR CONSTRUCTION DIFFUSER/GRILLE SCHEDULE SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES SIZE TITUS ML -38 AS NOTED MODULINEAR DIFFUSER WITH 2, 3/4" SLOT SPACING AND 4 FT LONG DISCHARGE SLOTS 120W 0 (CFM 1 \ SIZE - AS NOTED SLOT DIFFUSER FIELD VERIFY =/ CFM SIZE _ AS NOTED SLOT DIFFUSER FIELD VERIFY O CFM - AS NOTED SLOT DIFFUSER FIELD VERIFY \=./ CFM SIZE _ AS NOTED SLOT DIFFUSER FIELD VERIFY © CFM SIZE - AS NOTED SLOT DIFFUSER FIELD VERIFY O CFM SIZE - AS NOTED SLOT DIFFUSER FIELD VERIFY 0 CFM - AS NOTED RETURN GRILLE FIELD VERIFY © CFM SIZE - AS NOTED RETURN GRILLE FIELD VERIFY 0 CFM SIZE - AS NOTED MODULAR CORE FIELD VERIFY Q CFM SIZE - AS NOTED SIDE WALL REI URN GRILLE FIELD VERIFY Q CFM - AS NOTED SIDE WALL SUPPLY GRILLE FIELD VERIFY © CFM SIZE - AS NOTED MODULAR CORE FIELD VERIFY © CFM DUCT LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL ROUND SHEETMETAL WRAPPED W/ INSULATION (2 ") 14/12 120W SOUNDLINE SHEETMETAL (1" LINING) BARE FLAT OVAL SHEETMETAL 14/12 SL 14/128 SHEETMETAL WRAPPED W/ INSULATION (2 ") FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2 ") 14/12 W 14/12e-W BARE ROUND SHEETMETAL DUCTBOARD (1" FIBERGLASS) 120 14/12 DB EXAMPLE OF NEW EXAMPLE OF NOT IN CONTRACT (NIC) 14T2 14/12 EXAMPLE OF DEMO FLEX DUCT x x x x x x x x EXAMPLE OF EXISTING FLEX CONNECTOR 14/12 HVAC ABBREVIATIONS ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD- MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITAMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE -UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START /STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED TSTAT THERMOSTAT TC TEMPERATURE CONTROL TOD TOS TV TWG TWR TYP UNO VD VFD TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER No changes ; .w- �o to the scope tat work withou p: or app: of Tukwila B; slang Division. NOTE: Revisions Will require a new pan sut>iltal t and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: [a Mechanical refElectriad It (Gas PO MO City of Tukwila BUILDING DIVISION Date: ( -- FILEC.PY Permit Noe Pier leVieW *ppm! b to errors end missions. Approval of construction docu nos does not auM odic the violation of any adopted code or ordnance. Receipt of approved Reid Copy and olsadmooiedged: 0y City of Tukwila BUILDING DIVISION HVAC GENERAL NOTES 1. THE HVAC SYSTEM FOR THIS PROJECT IS BASED ON THE FOLLOWING CRITERIA COOLING INDOOR DESIGN TEMP (°F) = 75 COOLING OUTDOOR DESIGN TEMP ( °F) = 83DB, 67WB HEATING INDOOR DESIGN TEMP (°F) = 70 HEATING OUTDOOR DESIGN TEMP ( °F) = 20 2. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2003 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 4. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2003 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 5. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2004 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 2.0" 0.6 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R -3.3 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM (R -3.3 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R -3.3 MIN.). 7, FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 8' IN LENGTH UNLESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE 2003 IBC. 9. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2003 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2003 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 10.PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 11. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2003 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 1 12. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. 13. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 14. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND ACOMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 15. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC-2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 16.A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. LEGAL DESCRIPTION APN # 5422600160 LEGAL DESCRIPTION: 7 -8 MEADOWS THE MC NATTS D C 38 UNREC POR BEG ON N LN 179.98 FT E OF NW COR OF 8 TH S 89 DEG 17 MIN 51 SEC E ALG N LN 232.31 FT TH S 29 DEG 52 MIN 38 SEC E 520.79 FT TH N 89 DEG 58 MIN 17 SEC W 230.59 FT TH N 29 DEG 52 MIN 38 SEC W 524.20 FT TO BEG CONTACT LIST TITLE NAME COMPANY PHONE NUMBER FAX NUMBER PROJECT ENGINEER ACCOUNT EXECUTIVE SHEET METAL FOREMAN FIELD ENGR FOREMAN SIEMEN'S PROJ MNGR MICHELLE MULLIN BILLY LANGAN BRETT KILEKAS STEVE BAKER BEN SHARPE MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER SIEMENS 206- 768 -4254 206- 768 -3982 206 - 768 -4018 206 -768 -3824 425 - 507 -4390 206- 768 -4255 206 -768 -3983 206-768-4019 206 - 768 -3825 SCOPE OF WORK REMOVE EXISTING MEDIUM PRESSURE DUCTWORK AND PLUNGER STYLE DAMPERS FROM EXISTING ONE HUNDRED TWELVE (112) FAN POWERED VAV BOXES. FURNISH AND INSTALL ONE HUNDRED TWELVE (112) NEW VALVES AT THE INLET OF EACH EXISTING FAN POWERED VAV, INCLUDES ALL ASSOCIATED DUCTWORK MODIFICATIONS AS SHOWN ON PLANS. RELOCATE TWENTY EIGHT (28) EXISTING FAN POWERED BOXES TO ESTABLISH A 3 FOOT SECTION OF STRAIGHT DUCT TO THE INLET OF EACH BOX, INCLUDING ALL ASSOCIATED DUCTWORK MODIFICATIONS AS SHOWN ON PLANS. AIR BALANCE 112 ZONES. INSULATE ALL NEW AND ANY MODIFIED DUCTWORK PER CODE. FIELD VERIFY VALVE INLET SIZES. THERE MAY BE DISCREPANCIES BETWEEN PLANS AND FIELD INSTALLATION. CHANGE ORDER WILL BE ISSUED TO TAKE CARE OF ANY DISCREPANCIES IN THE FIELD. FIELD VERIFY VAV BOX RELOCATES AND REPORT ON AS- BUILTS. DRAWING SHEET INDEX NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.02 SCHEDULES AND DETAILS - HVAC DM2.01 N FIRST FLOOR NORTH DEMO PLAN- HVAC DM2.01S FIRST FLOOR SOUTH DEMO PLAN - HVAC TM2.01N FIRST FLOOR NORTH - HVAC TM2.01S FIRST FLOOR SOUTH - HVAC DM2.02N SECOND FLOOR NORTH DEMO PLAN- HVAC DM2.02S SECOND FLOOR SOUTH DEMO PLAN - HVAC TM2.02N SECOND FLOOR NORTH - HVAC TM2.02S SECOND FLOOR SOUTH - HVAC DM2.03N THIRD FLOOR NORTH DEMO PLAN- HVAC DM2.03S THIRD FLOOR SOUTH DEMO PLAN- HVAC TM2.03N THIRD FLOOR NORTH - HVAC TM2.03S THIRD FLOOR SOUTH - HVAC .5c r ,. Poetn3 ] 'rento St F!e§7/ 0 5 a St - co int . - . a.,rpbre 5 tIerndersgrl St 5 Director St 5 92nd PI S 93rd St tdtiene Webster s[ vy , 9a S. 5Aaste Sc nelner, St ' 5 ChicagoPOrtlana 5t St N o �1 s 5 Ih st'. N a N 9 , a w ,4 N y a � SITE MAP NO SCALE WORK SITE 9010 EAST MARGINAL WAY TUKWILA, WA 98108 •99tH 5 1i tix R 5 161st St S 102nd 5t s 164th St nn6 Ma.OGGS , Inc 5 193rd 5G 5 s riarrokrat 62QO. V1Eq, SHEET NUMBER: (\ VICINITY MAP I NO SCALE r oawbozz TM0.01 FIRST FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT /PH STGS CFM HP VOLT /PH /HZ SPD VAV -101 TRANE VFPE -1720 CORE 1320 0 10 27/15 0.25 0 - - 1355 1/2 277/1/60 - 1,2,3,4 VAV -102 TRANE VFPE -1715 SW CORNER 1130 225 10 27/15 0.12 9.0 277/1 3 1160 1/3 277/1/60 - 1,2,3,4 VAV -103 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -104 TRANE VFPE -1720 WEST WALL 1260 250 10 27/15 0.21 9.0 277/1 3 1295 1/2 277/1/60 - 1,2,3,4 VAV -105 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -106 TRANE VFPE -1720 WEST WALL 1260 250 10 27/15 0.21 9.0 277/1 3 1295 1/2 277/1/60 - 1,2,3,4 VAV -107 TRANE VFPE -1115 CORE 990 0 8 27/15 0.21 0 - - 1015 1/3 277/1/60 - 2,3,4 VAV -109 TRANE VFPE -1730 NW CORNER 1600 320 10 27/15 0.25 9.0 277/1 3 1640 2 @ 277/1/60 - 1,2,3,4 VAV -110 TRANE VFPE -0304 WORK ROOM 105 20 5 20/11 0.05 1.0 277/1 3 110 1/15 277/1/60 - 1,2,3,4 VAV -111 TRANE VFPE -0307 CONF ROOM 330 65 5 20/11 0.4 1.0 277/1 3 340 1/8 277/1/60 - 1,2,3,4 VAV -112 TRANE VFPE -1730 CORE 1190 240 10 27/15 0.11 9.0 277/1 3 1190 3/4 277/1/60 - 1,2,3,4 VAV -113 TRANE VFPE -0607 SE CORNER 370 75 6 20/11 0.21 3.5 277/1 3 380 1/8 277/1/60 - 1,2,3,4 VAV -114 TRANE VFPE -2430 CORE 1980 0 12 27/15 0.22 0 - - 2030 2 @1/3 277/1/60 - 2,3,4 VAV -115 TRANE VFPE -1111 EAST WALL 860 175 8 20/11 0.17 4.5 277/1 3 885 1/4 277/1/60 - 1,2,3,4 VAV -116 TRANE VFPE -2430 TRAINING ROOM 1 900 0 12 27/15 0.22 0 - - 990 2 @ 277/1/60 - 1,2,3,4 VAV -117 TRANE VFPE -1111 BREAK ROOM 1000 175 8 20/11 0.17 4.5 277/1 3 1000 1/4 277/1/60 - 1,2,3,4 VAV -118 TRANE VFPE -1111 BREAK ROOM 785 175 8 20/11 0.17 4.5 277/1 3 785 1/4 277/1/60 - 1,2,3,4 VAV -119 TRANE VFPE -1111 TRAINING ROOM 2 835 135 8 20/11 0.17 5.5 277/1 3 835 1/4 277/1/60 - 1,2,3,4 VAV -120 TRANE VFPE -1615 TRAINING ROOM 2 595 115 6 27/15 0.32 1.0 277/1 3 595 1/3 277/1/60 - 1,2,3,4 VAV -121 TRANE VFPE -0607 OBSERVATION ISLE 555 110 6 20/11 0.40 4.5 277/1 3 555 1/8 277/1/60 - 1,2,3,4,5 VAV -122 TRANE VFPE -1115 OBSERVATION ISLE 880 175 8 27/15 0.18 5.0 277/1 3 880 1/3 277/1/60 - 1,2,3,4,5 VAV -123 TRANE VFPE -0611 NORTH WALL EAST 600 120 6 20/11 0.45 4.5 277/1 3 600 1/4 277/1/60 - 1,2,3,4,5 VAV -124 TRANE VFPE -0607 ENVELOPE STORAGE 480 95 6 20/11 0.32 5.5 27711 3 480 1/8 277/1/60 - 1,2,3,4 VAV -125 TRANS VFPE -1115 ENVELOPE STORAGE 820 165 8 27/15 0.15 6.5 277/1 3 820 1/3 277/1/60 - 1,2,3,4 VAV -126 TRANE VFPE -0607 ENVELOPE STORAGE 400 80 6 20/11 0.20 2.0 277/1 3 400 1/8 277/1/60 - 1,2,3,4 VAV -127 TRANE VFPE -1720 OPENING 1400 0 10 27/15 0.26 0.0 277/1 - 1400 1/2 277/1/60 - 2,3,4 VAV -128 TRANE VFPE -1715 OPENING 1120 0 10 27/15 0.20 0.0 277/1 - 1120 1/3 277/1/60 - 2,3,4 VAV -129 TRANE VFPE -1730 OPENING 1540 0 10 27/15 0.23 0.0 277/1 - 1540 2 @1/3 277/1/60 - 2,3,4 VAV -130 TRANE VFPE -1115 OPENING 840 0 8 27/15 0.16 0.0 277/1 - 840 1/3 277/1/60 - 2,3,4 VAV -131 TRANE VFPE -1115 BALLOT VAULT 820 165 8 27/15 0.16 6.0 277/1 3 820 1/3 277/1/60 - 1,2,3,4,5 VAV -132 TRANE VFPE -1115 BALLOT VAULT 945 190 8 27/15 0.18 9.5 277/1 3 945 1/3 277/1/60 - 1,2,3,4 VAV -133 TRANE VFPE -0304 SPLITTING ROOM 240 45 5 20/11 0.21 1.0 277/1 3 240 1/15 277/1/60 - 1,2,3,4 VAV -134 TRANE VFPE -0304 SPLITTING ROOM 240 45 5 20/11 0.21 1.0 277/1 3 240 1/15 277/1/60 - 1,2,3,4,5 VAV -135 TRANE VFPE -0304 SUPPLY ROOM 100 20 5 20/11 0.05 1.0 277/1 3 100 1/15 277/1/60 - 1,2,3,4 VAV -136 TRANE VFPE -1730 OPENING 1540 0 10 27/15 0.23 0.0 277/1 - 1540 2 @1/3 277/1/60 - 2,3,4 VAV -137 TRANE VFPE -1115 OPENING 980 0 8 27/15 0.21 0.0 277/1 - 980 1/3 277/1/60 - 2,3,4 VAV -138 TRANE VFPE -0607 OBSERVATION ISLE 660 110 6 20/11 0.40 4.5 277/1 3 660 1/8 277/1/60 - 1,2,3,4 VAV -139 TRANE VFPE -1115 OBSERVATION ISLE 880 175 8 27/15 0.18 5.0 277/1 3 880 1/3 277/1/60 - 1,2,3,4,5 VAV -140 TRANE VFPE -0607 OBSERVATION ISLE 420 0 6 20/11 0.23 0.0 277/1 - 420 1/8 277/1/60 - 2,3,4 VAV -141 TRANS VFPE -0304 OBSERVATION ISLE 200 40 5 20/11 0.17 1.0 277/1 3 200 1/15 277/1/60 - 1,2,3,4,5 VAV -142 TRANE VFPE -2430 CAFETERIA 2050 850 12 27/15 0.26 10.0 277/1 3 2100 2 @1/3 277/1/60 - 1,2,3,4,5 VAV -143 TRANE VFPE -0304 ROLLS ROYCE 200 60 5 20/11 0.14 1.0 277/1 3 200 1/15 277/1/60 - 1,2,3,4 SECOND FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT /PH STGS CFM HP VOLT /PH /HZ SPD VAV -201 TRANE VFPE -1720 TABULATION 1400 280 10 27/15 0.29 9.5 277/1 3 1400 1/2 277/1/60 - 1,2,3,4 VAV -202 TRANE VFPE -1730 TABULATION 1665 335 10 27/15 0.28 0 277/1 - 1665 2 @1/3 277/1/60 - 2,3,4 VAV -203 TRANE VFPE -1720 TABULATION 1020 255 10 27/15 0.21 8.5 277/1 3 1020 1/2 277/1/60 - 1,2,3,4 VAV -204 TRANE VFPE -1730 VERIFICATION 1665 0 10 27/15 0.28 0 277/1 - 1665 2 @1/3 277/1/60 - 2,3,4 VAV -205 TRANE VFPE -2430 RECONCILIATION 2220 0 12 27/15 0.30 0 277/1 - 2220 2 @1/3 277/1/60 - 2,3,4 VAV -206 TRANE VFPE -1730 RECONCILIATION 1020 305 10 27/15 0.22 10.0 277/1 3 1020 2 @1/3 277/1/60 - 1,2,3,4 VAV -207 TRANE VFPE -1720 MAIL SORTING 1110 0 10 27/15 0.20 0 277/1 - 1110 1/2 277/1/60 - 2,3,4 VAV -208 TRANE VFPE -1115 MAIL SORTING 1020 205 8 27/15 0.23 8.0 277/1 3 1020 1/3 277/1/60 - 1,2,3,4 VAV -209 TRANE VFPE -0607 BALLOT VAULT 420 85 6 20/11 0.21 2.5 277/1 3 420 1/8 277/1/60 - 1,2,3,4 VAV -210 TRANE VFPE -1115 BALLOT VAULT 840 170 8 27/15 0.16 4.5 277/1 3 840 1/3 277/1/60 - 1,2,3,4 VAV -211 TRANE VFPE -0607 VESTIBULE 385 75 6 20/11 0.15 1.0 277/1 3 385 1/8 277/1/60 - 1,2,3,4,5 VAV -212 TRANE VFPE -0304 SUPPLY ROOM 145 30 5 20/11 0.16 1.0 277/1 3 145 1/15 277/1/60 - 1,2,3,4 VAV -213 TRANE VFPE -1730 BALLOT VAULT 1665 0 10 27/15 0.28 0 277/1 - 1665 2 @ 277/1/80 - 2,3,4 VAV -214 TRANE VFPE -1115 BALLOT VAULT 1005 200 8 27/15 0.21 4.5 277/1 3 1005 1/3 277/1/60 - 1,2,3,4 VAV -215 TRANE VFPE -2430 INSERTION 2220 0 12 27/15 0.30 0 277/1 - 2220 2 @1/3 277/1/60 - 2,3,4 VAV -216 TRANE VFPE -2430 DUPLICATION 2010 405 12 27/15 0.25 8.5 277/1 3 2010 2 @1/3 277/1/60 - 1,2,3,4 VAV -217 TRANE VFPE -1715 INSERTION 1110 0 10 27/15 0.16 0 277/1 - 1110 1/3 277/1/60 - 2,3,4 VAV -218 TRANE VFPE -1115 DUPLICATION 1035 210 8 27/15 0.23 5.0 277/1 3 1035 1/3 277/1/60 - 1,2,3,4,5 VAV -219 TRANE VFPE -0304 SUPERINTENDANT 190 40 5 20/11 0.16 1.0 277/1 3 190 1/15 277/1/60 - 1,2,3,4,5 VAV -220 TRANE VFPE -0607 CONF ROOM 340 70 6 20/11 0.15 1.0 277/1 3 340 1/8 277/1/60 - 1,2,3,4,5 VAV -221 TRANE VFPE -1720 SW CORNER 1260 250 10 27/15 0.23 8.5 277/1 3 1290 1/2 277/1/60 - 1,2,3,4 VAV -272 TRANE VFPE -1115 WEST WALL 960 195 8 27/15 0.20 6.0 277/1 3 985 1/3 277/1/60 - 1,2,3,4 VAV -223 TRANE VFPE -1115 WEST WALL 960 195 8 27/15 0.20 6.0 277/1 3 985 1/3 277/1/60 - 1,2,3,4,5 VAV -224 TRANE VFPE -1715 NW CORNER 1140 230 10 27/15 0.20 9.0 277/1 3 1170 1/3 277/1/60 - 1,2,3,4 VAV -225 TRANE VFPE -2430 CORE 1920 0 12 27/15 0.23 0 277/1 - 1970 2 @1/3 277/1/60 - 2,3,4 VAV -226 TRANE VFPE -2430 CORE 1760 0 12 27/15 0.18 0 277/1 - 1805 2 @ 277/1/60 - 2,3,4 VAV -227 TRANE VFPE -0607 CONF ROOM 420 85 6 20/11 i23 1.0 277/1 3 430 1/8 277/1/60 - 1,2,3,4 VAV -228 TRANE VFPE -2430 CORE 2080 0 12 27/15 0.25 0 277/1 - 2135 2 @ 277/1/60 - 2,3,4 VAV -229 TRANE VFPE -2430 CORE 1920 0 12 27/15 0.23 0 277/1 - 1970 2 @1/3 277/1/60 - 2,3,4 VAV -230 TRANE VFPE -2430 NE CORNER 1950 385 12 27/15 0.24 8.5 277/1 3 2000 2 @1/3 277/1/60 - 1,2,3,4 VAV -231 TRANE VFPE -1720 EAST WALL 660 132 10 27/15 0.23 3.0 277/1 3 700 1/2 277/1/60 - 1,2,3,4,5 VAV -232 TRANE VFPE -1720 EAST WALL 1320 265 10 27/15 0.23 5.5 277/1 3 1355 1/2 277/1/60 - 1,2,3,4,5 VAV -233 TRANE VFPE -1115 SE CORNER 1020 205 8 27/15 020 5.0 277/1 3 1045 1/3 277/1/60 - 1,2,3,4 VAV -234 TRANE VFPE -0607 CORE 480 0 6 20/11 029 0 277/1 - 495 1/8 277/1/60 - 2,3,4 VAV -235 TRANE VFPE -0607 CONF ROOM 420 85 6 20/11 023 1.0 277/1 3 430 1/8 277/1/60 - 2,3,4 VAV -236 TRANE VFPE -0304 CMPTR ROOM 200 100 5 20/11 0.15 0 277/1 - 205 1/15 277/1/60 - 2,3,4,5 VAV -237 TRANS VFPE -1111 EAST WALL 660 132 8 20/11 0.15 3.0 277/1 3 700 1/4 277/1/60 - 2,3,4,5 VAV -238 TRANE VFPE -0607 LOBBY 500 0 6 20/11 0.30 0 277/1 - 525 1/8 277/1/60 - 2,3,4,5 VAV -239 TRANE VFPE -0607 LOBBY 500 0 6 20/11 0.30 0 277/1 - 525 1/8 277/1/60 - 2,3,4 VAV -240 TRANE VSEF08000 VERIFICATION 765 105 8 12/12 0.31 5.0 277/1 2 765 1/3 277/1/60 - 1 VAV -241 TRANE VSEF 1000R MAIL SORTING 1020 165 10 16/12 0.29 7.0 277/1 2 1020 1/2 277/1/60 - 1 VAV -242 TRANE VSEF06000 DATA UPLOAD/DATA 250 40 6 12/10 0.04 1.0 277/1 2 250 1/3 277/1/60 - 1 THIRD FLOOR VAV BOX SCHEDULE UNIT NO. MODEL NO. LOCATION VALVE CFM CONNECTION SIZE MIN INLET S.P. IN WG ELECTRICAL HEATING CORE FAN NOTES MAX MIN INLET (IN) OUTLET KW VOLT/PH STGS CFM HP VOLT /PH /HZ SPD VAV -301 - - 1170 - 8 - - - - - - - - - 3,4,5 VAV -302 - - 960 - 8 - - - - - - - - - 3,4,5,6 VAV -303 - - 1920 - 12 - - - - - - - - - 3,4,5 VAV -304 - - 1300 - 10 - - - - - - - - - 3,4,5 VAV -305 - - 910 - 8 - - - - - - - - - 3,4,5 VAV -306 - - 680 - 8 - - - - - - - - - 3,4,5,6 VAV -307 - - 800 - 8 - - - - - - - - - 3,4,5 VAV -308 - - 1170 - 10 - - - - - - - - - 3,4,5 VAV -309 - - 520 - 8 - - - - - - - - - 3,4,5,6 VAV -310 - - 550 - 8 - - - - - - - - - 3,4,5 VAV -312 - - 100 - 5 - - - - - - - - - 3,4,5 VAV -313 - - 500 - 6 - - - - - - - - - 3,4,5 VAV -314 - - 1600 - 10 - - - - - - - - - 3,4,5 VAV -315 - - 820 - 8 - - - - - - - - - 3,4,5 VAV -316 - - 430 - 6 - - - - - - - - - 3,4,5,6 VAV -317 - - 860 - 8 - - - - - - - - - 3,4,5 VAV -318 - - 940 - 8 - - t - - - - - - - 3,4,5,6 VAV -319 - - 850 - 8 - - - - - - - - - 3,4,5 VAV -320 - - 720 - 8 - - - - - - _ - - 3,4,5 VAV -321 - - 660 - 8 - - - - - - - - - 3,4,5 VAV -323 - - 680 - 8 - - - - - - - - - 3,4,5 VAV -324 - - 460 - 8 - - - - - - - - - 3,4,5 VAV -326 - - 560 - 6 - - - - - - - - - 3,4,5 VAV -327 .. - 620 - 8 - - - - - - - - - 3,4,5 VAV -329 - - 960 - 8 - - - - - - - - - 3,4,5 VAV -330 - - 700 - 8 - - - - - - - - - 3,4,5 VAV -331 - - 420 - 6 - - - - - - - - - 3,4,5 VAV -332 - - 200 - 5 - - - - - - - - - 3,4,5,6 VAV -333 - - 1384 - 8 - - - - - - - - - 3,4,5,6 VAV -334 - - 860 - 8 - - .. - - - - - - 3,4,5 VAV -335 - - 640 - - - - - - - .. - - 3,4,5,6 VAV -336 - - 800 - - - - - - - - .. - 3,4,5,6 VAV -337 - - 215 - 5 - - - - - - - - - 3,4,5 VAV -338 - - 440 - 6 - - - - - - - - - 3,4,5,6 VAV -339 - - 440 - 6 - - - - - - - - - 3,4,5 VAV -340 - - 345 - 6 - - - - - - - - - 3,4,5 VAV -341 - - 215 - 5 - - - - - - - - - 3,4,5 VAV -342 - - 490 - 6 - - - - - - - - - 3,4,5 1 NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL 03001 VALVE AT INLET OF FAN POWERED BOX COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, HELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) DESIGN AIRFLOWS ARE TAKEN FROM THE FLOOR PLANS - FIELD VERIFY AIRFLOWS AND FAN POWERED BOX MODEL AND HEATER KW (IF APPLICABLE). REPORT ON AS- BUILTS. 6) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. EXISTING FAN POWERED BOX WITH PLUNGER STYLE DAMPER VALVE REMOVED L 2' -0" FIELD FABRICATED ECC CAP NEW AIR VALVE FIELD VERIFY INLET SIZE 2' -0 MIN 36" 15 -1/2" FIELD FABRICATED ECC CAP VALVE INSTALLATION D ETAI L NO SCALE MINIMUM DIMENSION OF STRAIGHT MEDIUM PRESSURE DUCT 1 NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX: COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, FIELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX. INSTALL 03001 VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. NOTES: 1) UNIT PROVIDED WITH CONTACTORS, AIR FLOW SWITCH AND DISCONNECT. SWITCH WIRED AND MOUNTED ON UNIT. 2) UNIT PROVIDED WITH 3 SPEED FAN SWITCH WIRED AND MOUNTED ON UNIT. 3) INSTALL D3001 VALVE AT INLET OF FAN POWERED BOX: COOLING ONLY TERMINAL UNIT W/O HEAT -, SIZE AS LISTED, FIELD MOUNTED CONTROLS, CONTROLS BY OTHERS. FACTORY OPTIONS INCLUDE: - STANDARD 1/2" LINER - INLET SENSOR 4) DEMO EXISTING PLUNGER STYLE DAMPER FROM EXISTING FAN POWERED BOX. INSTALL D3001VALVE AT INLET OF FAN POWERED BOX, INLET SIZE ON SCHEDULE. FIELD VERIFY 3 FEET OF STRAIGHT MED PRESSURE DUCT BEFORE VALVE INLET. 5) RELOCATE VAV TO OBTAIN MINIMUM 3 FEET MEDIUM PRESSURE DUCT AT INLET. 1 I CODE' FEE ll�p Cit MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT REVISIONS: DATE 02 -16 -07 9010 BUILDING RECE WF[1 JAN 3 0 2008 PERMIT CENTEk 9010 EAST MARGINAL WAY TUKWILA, WA SCHEDULES & NOTES - HVAC ENGINEER M MULLIN CHECKED BY B GEZON CAD: N BECKER LasT REwsED: 02 -16 -07 DATE PLOTTED: 02 -16 -07 ISSUE DATE 02 -16 -07 DRAWING NUMBER: C - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM0.02 w z W J 0 0 NEW SUPPLY AIR DUCTS W ITH 1" DUCT LINING AND PERF, METAL COVER, (E) 12' -0" X 1' 1'0/8 - i FD 8/14 UP (E) TO TEF -5 (ON ROOF) 14/8 (E) 10/10 (E) —\ 300 CFM . I EG(E) 250 CFM V 24/24 --- RETU-RN- ePEN NC WITH HORIZONTAL FIRE DAMPER(E)— 12' -6" X 1' -6" RETURN AIR OPENING (E) 410 16/12 E � 850 CFM EXHAUST DUCTED THROUGH 2ND FLOOR TO ROOF MOUNTED FMCS CONTROL PANELS 41 . 0 ... 410 SUPPLY DUCT 0PENING(E) 48/8 RELIEF AIR GRILLES (E) (TYP 11) 1 220 � 0 220 220 80 0 200 8 r 185 CID 14/14 I 16/16 WALL LOUVER 1ST FLOOR DEMO PLAN NORTH - HVAC SCALE: Ys" = 1' -0" 16/16 EG (E) 500 CFM 6/4 � 6 6 EG (E) 80 CFM 12/10 (E) 10/10 UP (E) 10/8 UP (E) CCD 10 /10 (E) -1r- 10/10 EC (E) 500 CFM FIELD NOTES: GENERAL NOTES: 0 VERIFY 36" CLEARANCE FOR ELEC. O FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. 0 FV CONNECTED LP DUCT AND DIFFUSER AND RECONNECT. REPORT ON AS BUILTS. VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2, VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. TIM' o1s. P MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 1� CD /PERMIT 02-16-07 REVISIONS: DATE 9010 BUILDING -kec H"VELA JAN 3 0 2006 PERMrr CENTER 9010 EAST MARGINAL WAY TUKWILA, WA DRAWING NUMBER: C - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: DM2D1N 1ST FLOOR DEMO PLAN NORTH - HVAC ENGINEER: M MULLIN CHECKED BY: LAST REVISED: 02 -16 -07 DATE PLDTTa; B GEZON 02-16-07 CAD: ISSUE DATE N BECKER 02-- -16 -07 1ST FLOOR PLAN NORTH - HVAC ENGINEER LAS REVISED: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: 0 - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2eO1N (E) 12' -0' X 1' -4" 18" NEW SUPPLY AIR DUCTS WITH 1" DUCT LINING AND PERF. METAL COVER. 1.40 T FD 8/14 UP (E) TO TEF-5 (ON ROOF) 14/8 (E) 10/10 (E) 10/8 ( ) 410 24/24 i1 30Q CFM ' /10 EG(E) I. 250. CFM 12' -6„ X 1 ' -6 " T RETURN AIR OPENING (E) 410 16/12 850 CFM EXHAUST DUCTED THROUGH 2ND FLOOR TO ROOF MOUNTED WITH HORIZONTAL FIRE DAMPER(E) 410 EMCS CONTROL PANELS 410 410 SUPPLY DUCT OPENING(E) 330 48/8 RELIEF AIR GRILLES (E) (TYP 11) 220 22 8 185 14/14 1 ST FLOOR PLAN NORTH - HVAC SCALE: Y&' = 1' -0" 1/16 WALL LOUVER 16/16 x-12/ 12 EG (E) 500 CFM 6/4 (E) 6 6 EG 80 CFM A\ r=cip 12/10 (E) 10/10 UP (E) 10/8 UP (E) 10/10 (E) Co) _ 10/10 EG (E) 500 CFM FIELD NOTES: 01 VERIFY 36" CLEARANCE FOR ELEC. O FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. 0 FV CONNECTED LP DUCT AND DIFFUSER AND RECONNECT. REPORT ON AS BUILTS. GENERAL NOTES: CODE COMi- ,L1; CODE VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 - 767 -6773 www.macrniller.com WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT REVISIONS: DATE 02-16-07 9010 BUILDING RECEIVED JAN 3 0 2008 PERMIT CENTER 9010 EAST MARGINAL WAY TUKWILA, WA A Li r r 16/16 WALL LOUVER— ( D) 10 8 .U-PE 12/1 400 48/8 RELIEF GRILLE {E) (TYP 14) �:) F fi , 8/14 UP(E) TO TEF -5 ON ROOF 118 1 L------34/28 RETURN AIR OPENING 1ST FLOOR DEMO PLAN SOUTH - HVAC SCALE: V& = 12' --0" X 1' -4" RETURN AIR OPENING (E) FIELD NOTES: 0 FV MIN 3F7, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. 1. 2. 3. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. VAV BOX OUTLET DUCT SIZE I5 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. long • l' —AN MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDOFS98ORLI I EXPIRES: 07 -06 -08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING RECEDE JAN 3 0 2008 PERMIT C:ENTEI 9010 EAST MARGINAL WAY TUKWILA. WA 1ST FLOOR DEMO PLAN SOUTH - HVAC ENGINEER: LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY: DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 DRAWING NUMBER: C - 1461 - 7275035 -- 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: DM2D1S w z W 0 U B 16/16 WALL LOUVER - (i ) 7 E r: 80 C M E(E FM (a> 48/8 RELIEF GRILLE (E) (TYP 14) 6 1ST FLOOR PLAN SOUTH - HVAC SCALE: Ys" — 1' -0" 8/14 UP(E) TO TEF -5 ON ROOF 34/28 RETURN AIR OPENING 12' -0" X 1' -4" RETURN AIR OPENING (E) FIELD NOTES: Q FV MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. GENERAL NOTES: VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. •M2 01 S 0 CODE -. r KEY PLA C`l MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU CD /PERMIT REVISIONS: 02 -16 -07 DATE 9010 BUILDING RECE JAN 3 0 2008 PERMIT CENT E1- 9010 EAST MARGINAL WAY TUKWILA. WA 1ST FLOOR PLAN SOUTH - HVAC ENGINEER: M MULLIN CHECKED BY: B GEZON CAD: N BECKER LAST REVISED: 02 -16 -07 DATE PLOTTED: 02 -16 -07 ISSUE DATE: 02-16-07 DRAWING NUMBER: 0-- -1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2.01S 1- 1 — = 0 0 0 z Ld 0 0 0 LL ) N n MacDonald - Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU • , ,' .P - 36163 1 w : - tO NA :. 1 EXPIRES: 07 -06 -08 \ CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING ' r: , ID'S f EU JAN 3 0 2008 ?Ei-t►vir OalTER 9010 EAST MARGINAL WAY TUKWILA, WA 2ND FLOOR DEMO PLAN NORTH - HVAC I ENGINEER: LAST REVISED: M MULLIN 02 -16 -07 I CHECKED BY DATE PLOTTED: ' B GEZON 02-16-07 ; • CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: I C- 1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: I 0M2.02N , 34/28 4240 C 36/18 2955 CFM FD 7 7 18? 950 CFM TYP 6 315 . 240 18/120 n�ww 80 160 27/14 10 �' 160 80 8r 330 1 • 1'60 1201 0 325 1 , 70/18 21? 79 : FD FD RETURN AIR ELEC. BASE BOARD HEATING (E) SEE SHEET M50,3 FOR RETURN AIR DETAILS SEE SHEEI M501 FOR A/C THIS AREA RETURN AIR 16/16(E) 500 CFM ' FD 6/18 FD 56/18 FD L. 120 1 20 -A \ ;3000 CFM I 18 70 CFM P ;6 210 D 3000 CFM 160 80 a 0 210 8 0 330 0/10> • 330 80 48/8 RELIEF AIR GRILLE (E) (TYP 11) 240 80 120 /. 330 330 E 240 80' 80 1 2/12 100 10 285 /4 6/4 (E) 10/10 .(E) ON ROOF 16/16 WALL LOUVER 1 6/1 6 EXISTING 10 14 UP TO RETURN GRILLES TYPICAL FOR EAST AND WEST WALLS 1 2/ 1 0 (E) 14/1.0 (E) 10/10 DOWN (E) 14/10 UP (E) 6 /6EG (E D 80 CFM 10/10EG (E) 300 CFM 2ND FLOOR DEMO PLAN NORTH - HVAC SCALE: Ys" = 1 ' -0" GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. 1 2 02ST � A ` - yc °w f , E Y ANk w 34/28 4240 CFM 36/18 2955 C M -- --- FD V I 18? 950 CFM TYP 6 ,�� 18 � 7 p 3000 CFM1 315 240 18/120 memo 80 100 1 80 160 CAP' 0160 80 14/12 1 8/1 80 80 i 180 ';80 ,1.4. =3 80 8 160 160 1 8o 160 160 . 160 27/)4 =3/4" 0 330 160 80 T 1 ' i ! ' lll 120 4 \\ 33 1201 Q/ ED } 70/18 FD RETURN AIR (Th ELEC. BASE BOARD HEATING (E) SEE SHEET M503 FOR RLIURN AIR DETAILS SEE SHEET M501 FOR A/C THIS AREA RETURN AIR 16/16(E) 500 CFM FD 46 FD FD J 315 120 340 120 /1 1 120 1 340 lft it, J I , 24 I, 24 80 1 1 1 330 t 0/10 330 80 \ 48/8 RELIEF AIR GRILLE (E) (TYP 11) 0240 80 330 330 80 240 \ 240 80 80 t 80' \ 80 CAP 240 n 12/12 100 10 14/ 520CF v �1) 1285 g2 5 /4" 6/4 (E) .1.4 10/10 (E) 16/16 WALL LOUVER 16/16 2ND FLOOR PLAN NORTH -- HVAC SCALE: Ys" — 1' —O" 12/10 (E) (E ~ - 10/10 DOWN (E) EXISTING 10 14 UP TO ON ROOF RE I URN GRILLES TYPICAL FOR EAST AND WEST WALLS 14/10 UP (E) 6 /6EG (E 80 CFM 10/10EG (E) 300 CFM E (F) FIELD NOTES: p FIELD VERIFY 8 "0 AT INLET FOR 8 "0 VAV BOX_ REPORT ON AS— BUILTS. FIELD VERIFY MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. GENERAL NOTES: VAV BOX INLET DUCT SIZE 15 SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE 15 SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3, DIFFUSER DUCT 15 SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4_ DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. n t;) 6 ' F ` f r MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 - 767 -6773 w ww.macrmiller.corn WA Lic No: MACDOFS980RU 1 EXPIRES: 07 -06 -08 CD /PERMIT REVISIONS: DATE 02 -16 -07 9010 BUILDING RECE VEI JAN 3 0 2008 PERMIT CEN Li 9010 EAST MARGINAL WAY TUKWILA, WA 2ND FLOOR PLAN NORTH - HVAC ENGINEER LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 DRAWING NUMBER: C- 1461- 7275035 -00 ISSUED FOR CONSTRUCTION SHEET NUMBER: TM2.02N ra 0 N 0 2 H L() h7 0 Lr) N N i- 0 0 0 z w 0 0 0 to N N N w z J_ LL 0 0 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 -763 -9400 Fax: 206 -767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU . g j ,:. . 0 AS 0 1 r 'fir/ 36163 4,, :..- _.. - ZONAL EXPIRES: 07 -06 -08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING RF JAN 3 0 2008 PERMIT CENTEh 9010 EAST MARGINAL WAY TUKWILA, WA c 2ND FLOOR DEMO PLAN SOUTH - HVAC c c c h u N C ENGINEER_ LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY DATE PLOTTED: B GEZON 02 -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 u C c G F c L DRAWING NUMBER: C- -1461- 7275035 -00 "E C u N c ISSUED FOR CONSTRUCTION is SHEET NUMBER: DM2D2S 2 V 16/16 WALL LOUVER C 48/8 EXISTING RELIEF AIR (TYP 15) �5 2ND FLOOR DEMO PLAN SOUTH - HVAC SCALE: Y8" — 1' -0" SEE SHEET M501 FOR A/C THIS AREA 24"0 FOR CONTINUATION SEE SHEET 2M10 21 "0 34/28 RETURN AIR OPENING 36/18 RETURN AIR OPENING 18? RETURN AIR OPENING (TYP. OF 6) • E`' FL /\ r.J MacDonald-Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206- 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU 0 36163 w .�w 3 .4 4. S' -. GI S' =, - ZONAL -- ._ `EXPIRES: 07-06-08 CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING RE :YEE JAN 3 0 2008 PERMIT CEN T Eri , 9010 EAST MARGINAL WAY TUKWILA, WA c 2ND FLOOR PLAN SOUTH - HVAC c c c. 1— rr. G ENGINEER: LAST REMISED: M MULLIN 02 -16 -07 CHECKED BY: DATE PLOTTED: B GEZON 02- -16 -07 CAD: ISSUE DATE: N BECKER 02 -16 -07 LC n C\ i I- Y U C ■ 0 w DRAWING NUMBER: C - 1461- 7275035 -00 ■ 0 0 in r. 0 ISSUED FOR CONSTRUCTION Ln r- w SHEET NUMBER: TM2SO2S a Z w J Li Q 0 'A) 16/16 WALL LOUVER F 48/8 EXISTING RELIEF AIR (TYP 15) 2ND FLOOR PLAN SOUTH - HVAC SCALE: Ya" = 16/16 (E) 500 CFM SEE SHELI M501 FOR A/C THIS AREA 24 "0 FOR CONTINUATION SEE SHEET 2M10 21 "0 34/28 RE I URN AIR OPENING 36/18 RETURN AIR OPENING 18? RETURN AIR OPENING (TYP. OF 6) FIELD NOTES: O FIELD VERIFY MIN 3FT, STRAIGHT DUCT AT INLET. MODIFY MP INLET AS REQ'D TO MEET 3FT MIN. GENERAL NOTES: 1. VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. :�, 7 MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206 - 763 -9400 Fax: 206 - 767 -6773 www.macmiller.com WA Lic No: MACDOFS980RU ... t� 0 � sg O . T OSS' i i j G' V` .: 4�r �r; o 36163 4,, 4SjONA1, - I EXPIRES: 07-06-08 I CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING JAN 3 0 2008 PERMIT CENTEF, 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR DEMO PLAN SOUTH - HVAC ENGINEER: LAST REVISED: M MULLIN 02 -16 -07 CHECKED BY: DATE PLOTTED: B GEZON 02 -16 -07 . CAD: ISSUE DATE N BECKER 02 -16 -07 DRAWING NUMBER: C - 1461 - 7275035 - 00 ISSUED FOR CONSTRUCTION SHEET NUMBER: DM2803S i ( I() EXISTING 24/10 UP TO TEF -3 ON ROOF 201 120 r \ 320 16/16 WALL LOUVER — 16/8 76 0 (e) EXISTING 10/8(E) EXIST. 8/6(E) EXISTIN 8 /6(E) (6) 320 200 320 320 320 T Tra 320 FI� 260 320 48/8 RELIEF AIR GRILLE(E) (TYP 14) 320 320 - 3' ;6? 220 IP11 44 14 1■ - _., 120 320 320 320 320 E3 3RD FLOOR DEMO PLAN SOUTH - HVAC SCALE: V8 = 1 - 0 " 26 "0 SUPPLY AIR DUCT FROM EXISTING PLENUM SEE DWG. M500 6" SPRINKLER MAIN (G� 10' -8" A.F.F.) c 1 ' - 1 L Ii r 7t a r t r ' MacDonald- Miller FACILITY SOLUTIONS 7717 Detroit Avenue SW Seattle, WA 98106 Phone: 206- 763 -9400 Fax: 206 -767 -6773 www.macmiIler.corn WA Lic No: MACDOFS98ORU 4 �7 ,o ( /J r' , I - � 36163 w _.. s ems ..::: ZONAL I EXPIRES: 07 -06 -08 l 7143A n CD /PERMIT 02 -16 -07 REVISIONS: DATE 9010 BUILDING JAN 3 0 2008 itAIvlu• CENTER 9010 EAST MARGINAL WAY TUKWILA, WA 3RD FLOOR PLAN SOUTH - HVAC A ENGINEER: LAST REVISED: M MULLIN 02--- 16 ---07 CHECKED BY: DATE PLOTTED: B GEZON 02 -16 -07 - CAD: ISSUE DATE: N BECKER 02 -16 -07 I DRAWING NUMBER: C - 1 461- 7275035 -00 .. 7�- d.11.1 ISSUED FOR 1 CONSTRUCTION SHEET NUMBER: TM2s03S I� 100 l 7143A - A 7�- d.11.1 • co 8 u t .rr ao a zi 130 27%4-3/4I 130 8 1 (6) EXISTING 24/10 UP TO TEF -3 ON ROOF 16/16 WALL LOUVER 320 320 320 320 48/8 RELIEF AIR GRILLE(E) (TYP 14) 320 i 130 51 5d/1 ? 1 14 7 12 /120 N 320 320 6) rittir , , LC 320 120 320 320 320 'FD 3RD FLOOR PLAN SOUTH -- HVAC SCALE: Y3" — 1' -0" 26 "0 SUPPLY AIR DUCT FROM EXISTING PLENUM SEE DWG. M500 6" SPRINKLER MAIN (_ 10' -8" A.F.F.) FIELD NOTES: O RELOCATE VAV BOX AS REQUIRED TO MEET 3FT MIN. MED PRESSURE AT INLET. O MODIFY DUCT AS REQ'D TO MAINTAIN 3FT MIN STRAIGHT M.P. DUCT AT INLET. GENERAL NOTES: VAV BOX INLET DUCT SIZE IS SAME AS VAV BOX INLET SIZE. 2. VAV BOX OUTLET DUCT SIZE IS SAME AS VAV BOX OUTLET OPENING UNLESS NOTED OTHERWISE. 3. DIFFUSER DUCT IS SAME SIZE AS DIFFUSER INLET CONNECTION UNLESS NOTED OTHERWISE. 4. DO NOT INSTALL VAV BOXES ABOVE LIGHT FIXTURES OR WALLS. r` r r f T ft 'LAC \I