HomeMy WebLinkAboutPermit D06-065 - Hellmann Worldwide Logistics - Storage RacksHELLMANN WORLDWIDE
LOGISTICS
18289 OLYMPIC AV S
D06 -065
City O Tukwila
Parcel No.: 7888900152
Address: 18289 OLYMPIC AV S TUKW
Suite No:
Tenant:
Name: HELLMANN WORLDWIDE LOGISTICS
Address: 18289 OLYMPIC AV 5, TUKWILA WA
Owner:
Name: CAMPBELL TAMES ESTATE
Address: 1001 KAMOKILA BLVD, KAPOLEI HI 96707
Phone:
Contact Person:
Name: MIKE SORENSON
Address: 1100 SW 7 ST, RENTON WA 98055
Phone: 206 818 -4488
Architect of Record:
Name: -
Address: ,
Phone:
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: ci.tukwila.wa.us
Engineer of Record:
Name: RACK DESIGN & ENGINEERING CO, ATTN GARY OHAN - 412 W BROADWAY #204
Address: GLENDALE CA, 91204
Phone: 818 240 -3810
Contractor:
Name: NORTH WEST HANDLING SYSTEMS INC
Address: 1100 S.W. 7TH STEET, RENTON, WA 98055
Phone: 206 255-0500
Contractor License No: NORTHWH275JF
DESCRIPTION OF WORK:
INSTALLATION OF NEW PALLET RACKING.
Value of Construction: $0.00
Type of Fire Protection: SPRINKLERS
Type of Construction:
doc: IBC- PERMIT
DEVELOPMENT PERMIT
* *continued on next page **
Expiration Date:10 /09/2007
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -065
Issue Date: 03/20/2006
Permit Expires On: 09/16/2006
Fees Collected: $718.79
International Building Code Edition: 2003
Occupancy per IBC:
006 -065 Printed: 03-20-2006
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Permit Center Authorized Signature:
Print Name:
doc: IBC - PERMIT
City oid Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ci.tukwila.wa.us
Fire Loop Hydrant: N Number: 0 Size (Inches): 0
Flood Control Zone:
Hauling: Start Time: End lime:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End lime:
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non - Profit: N
Water Main Extension: Private: Public:
Water Meter: N
I hereby certify that I have read and min J is permit and know the same to be true and correct. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating construction or the rformance ork. I am authorized to sign and obtain this development permit.
Signature: Date: aO 6
Steven M. Mullet, Mayor
Steve Lancaster, Director
Permit Number: D06 -065
Issue Date: 03/20/2006
Permit Expires On: 09/16/2006
Date: tr'71
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
D06 -065 Printed: 03 -20 -2006
City of 'I
PERMIT CONDITIONS
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7888900152 Permit Number: D06 -065
Address: 18289 OLYMPIC AV S TUKW Status: ISSUED
Suite No: Applied Date: 02/28/2006
Tenant: HELLMANN WORLDWIDE LOGISTICS Issue Date: 03/20/2006
1: ***BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
6: ***FIRE DEPARTMENT CONDITIONS***
7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the
following concerns:
8: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated
at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry
chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1)
9: Portable fire extinguishers, not housed in cabinets, shall be Installed on the hangers or brackets supplied. Hangers or
brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation
Instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so
that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross
weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the
floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4
inches (102 mm). (IFC 906.7 and IFC 906.9)
10: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot
be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6)
11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available
for use. These locations shall be along normal paths of travel, unless the fire code official determines that the
hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5)
12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that
indicates the month and year that the inspection was performed and shall identify the company or person performing the
service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge
procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the
inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these
required surveys. (NFPA 10, 4 -3, 4-4)
doc: Conditions 006 -065 Printed: 03-20 -2006
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
13: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.
(IFC 1008.1.8.3 subsection 2.2)
14: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle
is engaged from inside the tenant space. (IFC Chapter 10)
15: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the
International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC
1008.1.8.1)
16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10)
17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress
travel Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants Exit sign placement shall be such that no point in an exit access
corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less from the
nearest visible exit sign. (IFC 1011.1)
18: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with
the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having
a width not Tess than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be
less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire
Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high
contrast with the background and shall be clearly discemible when the exit sign illumination means is or is not
energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction
cannot be readily changed. (IFC 1011.5.1)
19: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system
provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3)
20: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means
of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the
floor level. The power supply for the means of egress illumination shall normally be provided by the premise's
electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less
than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2,
1006.3)
21: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or
combustible materials on pallets or In racks more than 12 feet in height. For certain special - hazard commodities such
as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6
feet. (IFC 2302)
22: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13 -12 3 1 14.1)
23: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and
multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted.
(NFPA 13- 12.3.1.13)
24: Maintain fire alarm system audible/visual notification. Addition /relocation of walls or partitions may require
relocation and /or addition of audible/visual notification devices. (City Ordinance #2051)
doc: Conditions D06 -065 Printed: 03-20-2006
City of Thkwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire
Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC
104.2)
26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and
#2051)
27: My overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of
such condition or violation.
28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at
(206)575 -4407.
* *continued on next page**
doc: Conditions 006-065 Printed: 03-20 -2006
Signature:
City of 1akwila
Print Name: V-4/ Jolihro
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Date:242 -04
doc: Conditions 006 -065 Printed: 03 -20 -2006
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print**
�-J King Co Assessor's Tax No.. r
Y —
Site Address: (b 2 '9 /J �C.i+n i� /Vet _a Suite Number: Floor: /
Tenant Name: ar s New Tenant: Q .... Yes e g..No
Property Owners Name: eledp Of rrAns 6,0,„ e Agia=,)
Mailing Address:Mtn : terf nil t (as mites C 1 /0/c 6/i ni r g' /ao $ r/YAth -- Cea
City State / ter ZIP /
CONTACT PERSON
Name: A t ke. Z5OrrIA.Cerit Day Telephone:Rao -tip-4417p
Mailing Address: 1/00 C. W • 7 x t rt7tntin &4t 9c05
/ rJ Zip
E -Mail Address: 1/Y1 f Of2,V1S0,7 (k 4 W lit S . Cann Fax Number: -7 a•S - ,t; ?g ^ 6 Ygyt7
GENERAL CONTRACTOR INFORMATION
Company Name: a kio, {n Lte-rf Ra /it
Mailing Address: //Qo 5 iv. 7 S S ?`
Contact Person: /"ltle-e- ,c70 t4tCftn
E- Mail Address: iv' co/rn-x(3" @ /)u /hS re) ivy
Contractor Registration Number: /vor44 l tt/ k ? 7 S ,rr
"An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance **
AARCIIITECT, r OF RECORD - O ptatis must be wet stauiped by Architett OtReeord
Company Name:
Mailing Address:
Contact Person:
E- i dress:
ENGINEER OF RECORD - MI plans must be wet stamped by Engineer of Record
Company Name: n(-.k- 3 /rn F £j tveen �.
Mailing Address: /(2 'Q•• Cj[/ � 'Y04/ /
# 1911 Y
r Contact Person: ( /k4'n
E -Mail Address:
•apptia4aatpamit application (1-2003)
1!200)
Page 1
City State
Sysi€#..s Jnc.
4 --. - 'Noss -
City State Zip
Day Telephone:a9 /, 6 ` / - Wei
P
Fax Number: GI S �a G 04
Expiration Date: /O 9/0 7
State
Co •
t emdJ G4 g /..ate
ity Day Telephone: /e^ fC 'Z8»
FaxNumber:gig fYU ' .2/3
City
Day Telephone:
Fax Number:
Zip
Valuation of Project (contractor's bid price): $ i�,-1 57J0' Existing Building Valuation: $
Ass
Scope of Work (please provide detailed information):
/t7C/7 fe OP et G Cht, J fl&a i+o
Oft C
Will there be new rack storage? a. Yes
Fldor'
.. No
Provide ill Building Areas in Sgusre Footage Below:
Floors
•
. 'Basement
Accessory Structure* •
Attached „Garage
Dfitached Garage
Attached Carport
Detached Carport
Covered Deck Uncovered .Deck
'applications\pamit application (1-2003)
1)200)
terior
Ex isting Remodel
If "yes ", see Handout No.
Addition to
Existing
Shtleture '
Page 2
OHgjn Lao fi
for requirements.
Type;of
Construct
per i7BC
Type of
Occupancy
= UBC
__add
rail"
PLANNINGDIVIS • N:
Single family building footprint (area of ate foundation of all structures, plus sny decks over 18 inches and overhangs greater Iran la inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑...Yes ❑.. No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
. Sprinklers ❑...Automatic Fire Alarm ❑...None ❑.. Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes a..No
If "yes". attach list of materials and storage locations on a separate 8 -1/2 x I paper indicating quantities and Material Safety Data Sheets.
UTILI a S:
Note: If the utility district is not 1 . . ila, you must provide written verification and approval from that utility district at the time of permit
application.
Water
..City ofTukwilaWaterDistrict ❑- . Water District #125 ❑ -..Hi; 1 •t er District ❑...City of Renton Water District
Sewer
❑.. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District 1 . ity of Seattle Sewer District
❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Hea
submitted at the time of permit application)
artment must be
P . BLIC:WORKS.PERMIT
Scope o Work (please provide detailed information):
Street Use:
D. Street Use
Land Altering and/or Hauling:
❑ .. Land Altering: ❑...Cut c t is yards ❑...Fill c .lc yards ❑ .. Hauling
Storm Drainage:
❑ .. Storm Drainage ❑...Flood Control Zone
Sewer Information:
0.. City of Tukwila Sewer District ❑.. Val Vue Sewer Dish of Renton Sewer District
❑.. Sanitary Side Sewer ❑.. Sewer Main Extension ❑ 'vate ❑.. Public
Water Information:
❑ .. City of Tukwila Water District ❑.. Water District # 125 ❑.. ighline Water District ❑...City of Renton Water District
❑ .. Water Main Extension 0.. Private ❑...Pub c
0.. Water Meter/Exempt: Size(s): ❑.. Deduct 0... Water Only
0.. Water Meter Permanent #: : IZe(s):
❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons
❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation
❑ .. Miscellaneous:
Monthly Service Billing to:
Name:
Mailing Address:
Water Meter Refund/Bil g:
Name:
Mailing Address:
Water...
1applic tiom‘yannit .ppliwlion (1 - 2003)
1t2003
Call before you Dig: 1- 800 - 424-5555
TION 206433 -0179
Please refer.to Public Works Bulletin #1 for fees and estimate sh t:
❑...Channeli : 'on/Striping ❑...Curb cut/Access/Sidewalk
Sewer ... ❑
Page 3
City
Sewage Treatment
❑ - City of Seattle Sewer District
Day Telephon
Day Telephone:
City
State
Ft
Line ....0
State
Zip
Zip
Unit Type.
Qty
Un ype:
Qty '
=Unit Type:
qty
Boiler/Compressor:.
Qty
Furnace<IOOK BTU
' Handling Unit
10,000 CFM
Other Mechanical
Equipment
0 -3 HP /100,000 BTU
Furnace >100K BTU
Evaporator Cooler
3- P /500,000 BTU
Floor Furnace
Ventilation Fan
15 -30 • ' 1,000,000 BTU
Suspended/Wall/Floor
Mounted Heater
Ventilation System
30 -50 HP/ , 0,000 BTU
Appliance Vent
Hood
50+ HP/1,750,000 :
Heat/Refrig/Coo ' g
System
Incinerator - Domestic
Air Handii Unit
< =10,00 CFM
Incinerator — Comm/Ind
MECH
Company N
Mailing Address:
Ciry State
Day Telephone:
Fax Number:
Expirati. Date:
* *An original or notarized copy of ent Washington State Contractor License m .e presented at the time of permit issuance **
Contact Person:
E -Mail Address:
Contractor Registration Number:
Valuation of Project (contractor's bid price S
Scope of Work (please provide detailed inform ' an):
Use: Residential: New .... ❑ Replace t nt....❑
Commercial: New .... ❑ Repl ement .... ❑
Fuel Type: Electric ❑ Gas ....0 Other:
Indicate type of mechanical work being i Iled and the quantity below:
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as
defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZ
Signature: ��
Print Name: f `
ft
Mailing Address: /100 S i _ -
Date Application Accepted:
\appliotiom \permit appIicatioa (1 -2003)
1/2003
024r; GU'
Page 4
Day Telephone: ?7- 'n8
City
Date: ,V,59 7 /F>
s
Staff Initials:
Zip
Zip
Date Application Expires: i '
Gte
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7888900152 Permit Number: D06 -065
Address: 18289 OLYMPIC AV S TUKW Status:. PENDING
Suite No: Applied Date: 02/28/2006
Applicant: HELLMANN WORLDWIDE LOGISTICS Issue Date:
Receipt No.: R06 -00272 Payment Amount: 718.79
Initials: NM Payment Date: 02/28/2006 01:11 PM
User ID: 1165 Balance: $0.00
Payee: MICHAEL J. SORENSON
TRANSACTION LIST:
Type Method Description
Payment Check 6645 718.79
ACCOUNT ITEM LIST:
Description
BUILDING - NONRES
PLAN CHECK - NONRES
STATE BUILDING SURCHARGE
Account Code Current Pmts
000/322.100
000/345.830
000/386.904
RECEIPT
432.90
281.39
4.50
Amount
Total: 718.79
2964 02/28 9716 TOTAL 718.79
doc: Receipt Printed: 02 -28 -2006
Project:
/I et i 47AA'AI
Type of Insp tion:
f /.v 4 /
Address:
nt26S OLVS"?' AUS
Date Called:
Special instructions:
Date Wan d:
.�— SO-0 L
Requester:
Phone No:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
06)431 -3670
pproved per applicable codes. D Corrections required prior to approval.
COMMENTS:
\ vvvt -I' c ervi 6-4 e a
O IL 'rcv rl+'u4!.
"ea-, k�
$5:.00 REINSPECTION FEE REQUIRED. or to inspection, fee must be
d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection.
Receipt No.:
Date:
COMMENTS:
Type of Insppee lion:
('i ri//f /
/ 4724 »U4 — ,O k 0
- r in Pe A U S
Date Called:
Special Instructions:
Date Wanted:
3
2Z-o G
�a. ,
Cpl
Requester:
Phone No:
e
R se Lo c0 4_7,14.4 S'°NS
yr)
C'FS44r R�rPk-5
Project:
,,'4[ E.5
ci 83(3
Type of Insppee lion:
('i ri//f /
Address:
- r in Pe A U S
Date Called:
Special Instructions:
Date Wanted:
3
2Z-o G
�a. ,
Cpl
Requester:
Phone No:
1-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Approved per applicable codes.
R Corrections required prior to approval.
t sp ` r, � 1 - �,�►
68.00 REINSPECTION \FEE REQUIRED. Pri
aid at 6300 Southcenter Blvd., Suite 1
Date
* -27 - d C
to inspection, fee must be
Call to sechedule reinspection.
Receipt No.:
'Date:
Project: /
H2'Imry World path L0 1$ >
Type Inspec# ion:
Art /
Address:
Suite #: I e.. '
p G ` S
Contact Person:
Phone No.:
Special Instructions:
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
1
INSPECTION NUMBER
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407
n Approved per applicable codes.
COMMENTS:
F; re . eiy f c pi ne P.,f *7 a o y4 Yo .f' C
/q ro SF
el. /WC(
Inspector:
Ei.o
Date:3l.
Hrs.:
$80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
at 444 Andover Park East. Call to schedule reinspection.
eipt No.:
Date:
Word /Inspection Record Form.Doc
INSPECTION RECORD
Retain a copy with permit
12/2/05
po6 —o6s
PERMIT NUMBERS
bd Corrections required prior to approval.
T.F.D. Form F.P. 85
0 , - A°rmlr N cop1r
NORTHWEST
e Material Han Iing Experts
RACK INFORMATION SUPPLEMENT
SITE ADDRESS: 18289 Olympic Ave 5.
TENANT NAME: Hellmann Worldwide Logistics
DATE: February 27, 2006
APPLICANT: Mike Sorenson / (206) 818 -4488
1100 SW 7th St
- '►onit
Renton, WA 98055 ,
(425) 255 -0500 ph
(425) 228 -6946 fax
RECEIVED
CITY OF TUKWILA
FEB 2 8 2006
PERMIT CENTEn
CODE COMPLIANCE
annnn'n:n
MAR 10 2006
City Of Tukwila
RI JTWTNC nn!gTflni
1. Load application and rack configuration drawings attached.
2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans
detail the building /ceiling configuration.
3. Stamped engineering calculations attached.
4. Vertical members of storage racks are designed and installed so that failure of one vertical
member will not cause collapse of more than the bay or bays directly supported by that
member.
5. Commodities stored: Component parts of medical defibrillators. Metal and plastic parts
stored in cardboard boxes on 40" wide X 48" long wood pallets. Some pallets are shrink
wrapped on sides only. No shrink wrap on top and bottom.
6. Sprinkler System Information: .39 GPM / 5600 square feet. Sprinkler head temperature: 165
degrees.
7. Smoke and heat vents: In place, not required for 10,000 square foot area.
8. Building egress and exits indicated on attached drawings.
B G. OHANIAN
BATE 2 -27 -06
SUBJECT
RAdK DEOI(N & ENgINEERINd d0.
412 WE BROADWAY, BUUTE #204
{iLENDALE, OA. 91204
TEL4818)240 -3810 FAX:(818)240 -3813
STRUCTURAL CALCULATIONS OF STORAGE
RACKS FOR:
FILE COPY
HELMANN WORLDWIDE 11361STICS
18289 OLYMPIC AVE: SO.
TUKWILA, WA.
PER IBC 2003 EDITION
STORAGE RACKS CAPACITY:
3000 # / LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD -10646
REVIEWED FOR
CODE COMPLIANCE
Andnn.tn
MAR 10 2006
aty Of Tukwila
RI III MC mac - inn,
SHEET NO 1
JOB NO. RD -10646
IEXPIRES 12 -26 -07
RECEIVED
CITY OF TUKWILA
FEB 2 8 2006
PERMIT CENTEh
BY G. OHANIAN
DATE. 2 -27 -06
SUBJECT
BEAM
3000 #/ LEVEL
+25% IMPACT LOAD
1700 #/ BEAM
SEISMIC DFSIGN
V= S °5 XI x w
RX 1 ' 4 WORKING
STRESS
1 =1
R =6
R =4
S =.8
W= D.L. +3 L.L.
LONGIT.
LOAD PER COLUMN
LL= 3x3 K — 4.5 K
2 ca.
+ K
W =.ta 3LI. = 3.1
.8x1x3.1 —.30x
6X1.4
V — .8x1x3.1 = 44K
TRANS. 4x1.4 •
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, OA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
x
i 3/4'
2 3/4'
IBC 2003, SEC. 2208
DOWN AISLE (MOM. CONN.)
CROSS AISLE (BRACED)
I =1.9
S =.9
Fy =50 /CSI
S =1.2
S =1.
S =2/3 S ys
1 ONf;IT. SFISMIC
M= 96 "x1.7 - 20 "K
6
S 3 0 'K =.7<.9
=
5xWxL — .46" <
384xl xE
USGS MAP
EQ. 16 -38
EQ. 16 -40
.30x
SHEET NO 2
JOB N0. RD -10646
44" 4 , 44" I
96
180
11 "x
_ .5„
1 1
.bS
1
�
1
BY G. OHANIAN
DATE. 2 -27 -06
SUBJECT
BEAM
3000 #/ LEVEL
+25% IMPACT LOAD
1700 #/ BEAM
SEISMIC DFSIGN
V= S °5 XI x w
RX 1 ' 4 WORKING
STRESS
1 =1
R =6
R =4
S =.8
W= D.L. +3 L.L.
LONGIT.
LOAD PER COLUMN
LL= 3x3 K — 4.5 K
2 ca.
+ K
W =.ta 3LI. = 3.1
.8x1x3.1 —.30x
6X1.4
V — .8x1x3.1 = 44K
TRANS. 4x1.4 •
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, OA. 91204
TEL:(818)240 -3810 FAX:(818)240 -3813
x
i 3/4'
2 3/4'
IBC 2003, SEC. 2208
DOWN AISLE (MOM. CONN.)
CROSS AISLE (BRACED)
I =1.9
S =.9
Fy =50 /CSI
S =1.2
S =1.
S =2/3 S ys
1 ONf;IT. SFISMIC
M= 96 "x1.7 - 20 "K
6
S 3 0 'K =.7<.9
=
5xWxL — .46" <
384xl xE
USGS MAP
EQ. 16 -38
EQ. 16 -40
.30x
SHEET NO 2
JOB N0. RD -10646
44" 4 , 44" I
96
180
11 "x
_ .5„
BY G. OHANIAN RACK DESIGN & ENGINEERING CO.
DATE 2 -27 -06 412 WEST BROADWAY, SUITE #204
SUBJECT GLENDALE, CA. 91204
TEL:(618)240 -3810 FAX:(816)240 -3613
COLUMN ANALYSIS
n
x-
t -.09" 1J
COMRINED STRESS RATIO
P a + M ;x= 16 +24 = .7 <1.33
RASE PLATE
ANCH. TENSION — 11 (6 =.2
ANCHOR SHEAR = 2 0 = 15 K
(2) -1/2 "91 HILTI KWIK BOLT 3
ESR -1385 OR EQUAL. (NO INSPECTION REQ'D)
DESIGNED FOR 1/2 STRESS
MOMFNT AT RFAM CON N FCTInN
'K
Fy =50 Ksi
A =.78
S =.80
r =1.2
r =1.1
— Z -60
I S — IL =47
y — 1.1
Max = S . Fy= 24"
2 PIN CCNNFCTOR
7/16 "0 RIVET
A =.1 Fy = 79 KSI
Va = .1x79x.4= 3K
Ma = 3 K x4 "x 1.33 = 16 -K
CONN.
2
Fe— ( K� \2 =100
r
Fn — Fy(1 49e ) =42 KSI
P F = 32 K
P P " — 16 K
° — 1.92 —
SHEET NO 3
JOB NO. RD -10646
7 3/4 "x5 "x3/8"
BASE PLATE
BY G. OHANIAN RACK DESIGN & ENGINEERING CO.
SHEET NO 4
JOB NO. RD -10646
DATE 2 -27 -06 412 WEST BROADWAY, QUITE #204
SUBJECT 4LENDALE, CA. 01204
TEL:(818)240 -3810 FAX:(818)240 -3813
TRANSVERSE SEISMIC
(OVERTURNING)
M = .44 Kx2x 182 "x.5x 1.15 = 93 'K
MR = 3.1 Kx42" = 130 - K
NO UPLIFT
I OAD TO IDIAGONAI
P =.44 4 =1.2
Fy =50 KSI
A =.31
r =.48
Q =.74
L= 56"
C: HFC'K WFLDS
1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL)
3x.125x.707x70x.3 = 5.7
C:J4FC'K SI A9
4600 4 6'
1000
=25"
• F — 1 1 .2 KSI
P = 3.5 K
4.6x144 =662 a "
M= ( )2x1000x 2 x12 =1500
S= 12x5 = 50
6
1500 = 30 G 1.6 2000 =72
50
TOP LEVEL LOADING
M = .14 Kx2x 182"= 50
MR= 1.2 " =50
4600 ti
SEC. R -8
5' CONCRETE SLAB
2000 PSI. CONC.
1000 PSF. SOIL
ACTIVITY NUMBER: D06 -065 DATE: 02 -28 -06
PROJECT NAME: HELLMANN WORLDWIDE LOGISTICS
SITE ADDRESS: 18289 OLYMPIC AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: 8 0 6
wyj ti Buil ing Division
Public Works
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete
Comments:
TUES/THURS ROUT I
Please Route Structural Review Required/ Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing siip.doc
2-28-02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Pr V
Structural
Approved with Conditions
Planning Division
❑ Permit Coordinator ❑
DUE DATE: 03-02-06
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
No further Review Required
DATE:
DUE DATE: 03-30-06
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
License Information
License
NORTHWH275JF
Licensee Name
NORTH WEST HANDLING SYS INC
Licensee Type
CONSTRUCTION CONTRACTOR
UBI
600051641
Ind. Ins. Account Id
32999900
Business Type
CORPORATION
Address 1
1100 SW 7TH ST
Address 2
City
RENTON
County
KING
State
WA
Zip
980552939
Phone
4252550500
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
4/6/1973
Expiration Date
10/9/2007
Suspend Date
Separation Date
Parent Company
Previous License
Next License
NORTHHS963ND
Associated License
Bond Information
Bond
Bond
Company
Name
Bond Account
Number
Effective
Date
Expiration
Date
Cancel
Date
Impaired
Date
Bond
Amount
Received
Date
TRAVS
81S103354822BCM
10/01/2001
Until
Cancelled
01/01/1980
$12,000.00
10/09/2001
Business Owner Information
Name
Role
Effective Date
Expiration Date
FRANCK, JAMES J
01/01/1980
THOMAS, KEVIN A
01/01/1980
KOSTY, CLARK R
01/01/1980
Look Up a Contractor, Electriri an or Plumber License Detail Page 1 of 3
Washington State Department of Labor and Industries
General/Specialty Contractor
A business registered as a construction contractor with L &I to perform
construction work within the scope of its specialty. A General or Specialty
construction Contractor must mamtain a surety bond or assignment of
account and carry general liability insurance.
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 03/20/2006
x
x