Loading...
HomeMy WebLinkAboutPermit D06-065 - Hellmann Worldwide Logistics - Storage RacksHELLMANN WORLDWIDE LOGISTICS 18289 OLYMPIC AV S D06 -065 City O Tukwila Parcel No.: 7888900152 Address: 18289 OLYMPIC AV S TUKW Suite No: Tenant: Name: HELLMANN WORLDWIDE LOGISTICS Address: 18289 OLYMPIC AV 5, TUKWILA WA Owner: Name: CAMPBELL TAMES ESTATE Address: 1001 KAMOKILA BLVD, KAPOLEI HI 96707 Phone: Contact Person: Name: MIKE SORENSON Address: 1100 SW 7 ST, RENTON WA 98055 Phone: 206 818 -4488 Architect of Record: Name: - Address: , Phone: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: ci.tukwila.wa.us Engineer of Record: Name: RACK DESIGN & ENGINEERING CO, ATTN GARY OHAN - 412 W BROADWAY #204 Address: GLENDALE CA, 91204 Phone: 818 240 -3810 Contractor: Name: NORTH WEST HANDLING SYSTEMS INC Address: 1100 S.W. 7TH STEET, RENTON, WA 98055 Phone: 206 255-0500 Contractor License No: NORTHWH275JF DESCRIPTION OF WORK: INSTALLATION OF NEW PALLET RACKING. Value of Construction: $0.00 Type of Fire Protection: SPRINKLERS Type of Construction: doc: IBC- PERMIT DEVELOPMENT PERMIT * *continued on next page ** Expiration Date:10 /09/2007 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D06 -065 Issue Date: 03/20/2006 Permit Expires On: 09/16/2006 Fees Collected: $718.79 International Building Code Edition: 2003 Occupancy per IBC: 006 -065 Printed: 03-20-2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Permit Center Authorized Signature: Print Name: doc: IBC - PERMIT City oid Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: Start Time: End lime: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End lime: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N I hereby certify that I have read and min J is permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the rformance ork. I am authorized to sign and obtain this development permit. Signature: Date: aO 6 Steven M. Mullet, Mayor Steve Lancaster, Director Permit Number: D06 -065 Issue Date: 03/20/2006 Permit Expires On: 09/16/2006 Date: tr'71 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. D06 -065 Printed: 03 -20 -2006 City of 'I PERMIT CONDITIONS Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900152 Permit Number: D06 -065 Address: 18289 OLYMPIC AV S TUKW Status: ISSUED Suite No: Applied Date: 02/28/2006 Tenant: HELLMANN WORLDWIDE LOGISTICS Issue Date: 03/20/2006 1: ***BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 6: ***FIRE DEPARTMENT CONDITIONS*** 7: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 8: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 9: Portable fire extinguishers, not housed in cabinets, shall be Installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation Instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4-4) doc: Conditions 006 -065 Printed: 03-20 -2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 13: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 14: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 15: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 16: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less from the nearest visible exit sign. (IFC 1011.1) 18: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not Tess than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discemible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 19: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 20: Means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. The means of egress illumination level shall not be less than 1 foot - candle (11 lux) at the floor level. The power supply for the means of egress illumination shall normally be provided by the premise's electrical supply. In event of a power failure an emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 21: High -piled combustible storage is combustible materials in closely packed piles more than 12 feet in height or combustible materials on pallets or In racks more than 12 feet in height. For certain special - hazard commodities such as rubber tires, plastics, some flammable liquids, idle pallets, etc., the critical pile height may be as low as 6 feet. (IFC 2302) 22: Maintain minimum 6" longitudinal flue space between back -to -back racks. (NFPA 13 -12 3 1 14.1) 23: Nominal 6" transverse flue spaces between loads and at rack uprights shall be maintained in single row, double row, and multiple row racks. Random variations in the width of flue spaces or in their vertical alignment shall be permitted. (NFPA 13- 12.3.1.13) 24: Maintain fire alarm system audible/visual notification. Addition /relocation of walls or partitions may require relocation and /or addition of audible/visual notification devices. (City Ordinance #2051) doc: Conditions D06 -065 Printed: 03-20-2006 City of Thkwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 25: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 27: My overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page** doc: Conditions 006-065 Printed: 03-20 -2006 Signature: City of 1akwila Print Name: V-4/ Jolihro Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date:242 -04 doc: Conditions 006 -065 Printed: 03 -20 -2006 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print** �-J King Co Assessor's Tax No.. r Y — Site Address: (b 2 '9 /J �C.i+n i� /Vet _a Suite Number: Floor: / Tenant Name: ar s New Tenant: Q .... Yes e g..No Property Owners Name: eledp Of rrAns 6,0,„ e Agia=,) Mailing Address:Mtn : terf nil t (as mites C 1 /0/c 6/i ni r g' /ao $ r/YAth -- Cea City State / ter ZIP / CONTACT PERSON Name: A t ke. Z5OrrIA.Cerit Day Telephone:Rao -tip-4417p Mailing Address: 1/00 C. W • 7 x t rt7tntin &4t 9c05 / rJ Zip E -Mail Address: 1/Y1 f Of2,V1S0,7 (k 4 W lit S . Cann Fax Number: -7 a•S - ,t; ?g ^ 6 Ygyt7 GENERAL CONTRACTOR INFORMATION Company Name: a kio, {n Lte-rf Ra /it Mailing Address: //Qo 5 iv. 7 S S ?` Contact Person: /"ltle-e- ,c70 t4tCftn E- Mail Address: iv' co/rn-x(3" @ /)u /hS re) ivy Contractor Registration Number: /vor44 l tt/ k ? 7 S ,rr "An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issuance ** AARCIIITECT, r OF RECORD - O ptatis must be wet stauiped by Architett OtReeord Company Name: Mailing Address: Contact Person: E- i dress: ENGINEER OF RECORD - MI plans must be wet stamped by Engineer of Record Company Name: n(-.k- 3 /rn F £j tveen �. Mailing Address: /(2 'Q•• Cj[/ � 'Y04/ / # 1911 Y r Contact Person: ( /k4'n E -Mail Address: •apptia4aatpamit application (1-2003) 1!200) Page 1 City State Sysi€#..s Jnc. 4 --. - 'Noss - City State Zip Day Telephone:a9 /, 6 ` / - Wei P Fax Number: GI S �a G 04 Expiration Date: /O 9/0 7 State Co • t emdJ G4 g /..ate ity Day Telephone: /e^ fC 'Z8» FaxNumber:gig fYU ' .2/3 City Day Telephone: Fax Number: Zip Valuation of Project (contractor's bid price): $ i�,-1 57J0' Existing Building Valuation: $ Ass Scope of Work (please provide detailed information): /t7C/7 fe OP et G Cht, J fl&a i+o Oft C Will there be new rack storage? a. Yes Fldor' .. No Provide ill Building Areas in Sgusre Footage Below: Floors • . 'Basement Accessory Structure* • Attached „Garage Dfitached Garage Attached Carport Detached Carport Covered Deck Uncovered .Deck 'applications\pamit application (1-2003) 1)200) terior Ex isting Remodel If "yes ", see Handout No. Addition to Existing Shtleture ' Page 2 OHgjn Lao fi for requirements. Type;of Construct per i7BC Type of Occupancy = UBC __add rail" PLANNINGDIVIS • N: Single family building footprint (area of ate foundation of all structures, plus sny decks over 18 inches and overhangs greater Iran la inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area for accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑...Yes ❑.. No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: . Sprinklers ❑...Automatic Fire Alarm ❑...None ❑.. Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes a..No If "yes". attach list of materials and storage locations on a separate 8 -1/2 x I paper indicating quantities and Material Safety Data Sheets. UTILI a S: Note: If the utility district is not 1 . . ila, you must provide written verification and approval from that utility district at the time of permit application. Water ..City ofTukwilaWaterDistrict ❑- . Water District #125 ❑ -..Hi; 1 •t er District ❑...City of Renton Water District Sewer ❑.. City of Tukwila Sewer District ❑.. Val Vue Sewer District ❑...City of Renton Sewer District 1 . ity of Seattle Sewer District ❑ .. Septic System (If property is served by a septic system, 2 copies of approved septic design from King County Hea submitted at the time of permit application) artment must be P . BLIC:WORKS.PERMIT Scope o Work (please provide detailed information): Street Use: D. Street Use Land Altering and/or Hauling: ❑ .. Land Altering: ❑...Cut c t is yards ❑...Fill c .lc yards ❑ .. Hauling Storm Drainage: ❑ .. Storm Drainage ❑...Flood Control Zone Sewer Information: 0.. City of Tukwila Sewer District ❑.. Val Vue Sewer Dish of Renton Sewer District ❑.. Sanitary Side Sewer ❑.. Sewer Main Extension ❑ 'vate ❑.. Public Water Information: ❑ .. City of Tukwila Water District ❑.. Water District # 125 ❑.. ighline Water District ❑...City of Renton Water District ❑ .. Water Main Extension 0.. Private ❑...Pub c 0.. Water Meter/Exempt: Size(s): ❑.. Deduct 0... Water Only 0.. Water Meter Permanent #: : IZe(s): ❑ .. Water Meter Temporary #: Size(s): ❑ .. Est. Quantity: gallons ❑ .. Fire Loop/Hydrant (main to vault) #: Size(s): ❑ .. Landscaping Irrigation ❑ .. Miscellaneous: Monthly Service Billing to: Name: Mailing Address: Water Meter Refund/Bil g: Name: Mailing Address: Water... 1applic tiom‘yannit .ppliwlion (1 - 2003) 1t2003 Call before you Dig: 1- 800 - 424-5555 TION 206433 -0179 Please refer.to Public Works Bulletin #1 for fees and estimate sh t: ❑...Channeli : 'on/Striping ❑...Curb cut/Access/Sidewalk Sewer ... ❑ Page 3 City Sewage Treatment ❑ - City of Seattle Sewer District Day Telephon Day Telephone: City State Ft Line ....0 State Zip Zip Unit Type. Qty Un ype: Qty ' =Unit Type: qty Boiler/Compressor:. Qty Furnace<IOOK BTU ' Handling Unit 10,000 CFM Other Mechanical Equipment 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler 3- P /500,000 BTU Floor Furnace Ventilation Fan 15 -30 • ' 1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System 30 -50 HP/ , 0,000 BTU Appliance Vent Hood 50+ HP/1,750,000 : Heat/Refrig/Coo ' g System Incinerator - Domestic Air Handii Unit < =10,00 CFM Incinerator — Comm/Ind MECH Company N Mailing Address: Ciry State Day Telephone: Fax Number: Expirati. Date: * *An original or notarized copy of ent Washington State Contractor License m .e presented at the time of permit issuance ** Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Project (contractor's bid price S Scope of Work (please provide detailed inform ' an): Use: Residential: New .... ❑ Replace t nt....❑ Commercial: New .... ❑ Repl ement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being i Iled and the quantity below: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review— Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined in Section 107.4 of the Uniform Building Code (current edition). No application shall be extended more than once. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZ Signature: �� Print Name: f ` ft Mailing Address: /100 S i _ - Date Application Accepted: \appliotiom \permit appIicatioa (1 -2003) 1/2003 024r; GU' Page 4 Day Telephone: ?7- 'n8 City Date: ,V,59 7 /F> s Staff Initials: Zip Zip Date Application Expires: i ' Gte City of Tukwila 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 7888900152 Permit Number: D06 -065 Address: 18289 OLYMPIC AV S TUKW Status:. PENDING Suite No: Applied Date: 02/28/2006 Applicant: HELLMANN WORLDWIDE LOGISTICS Issue Date: Receipt No.: R06 -00272 Payment Amount: 718.79 Initials: NM Payment Date: 02/28/2006 01:11 PM User ID: 1165 Balance: $0.00 Payee: MICHAEL J. SORENSON TRANSACTION LIST: Type Method Description Payment Check 6645 718.79 ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE Account Code Current Pmts 000/322.100 000/345.830 000/386.904 RECEIPT 432.90 281.39 4.50 Amount Total: 718.79 2964 02/28 9716 TOTAL 718.79 doc: Receipt Printed: 02 -28 -2006 Project: /I et i 47AA'AI Type of Insp tion: f /.v 4 / Address: nt26S OLVS"?' AUS Date Called: Special instructions: Date Wan d: .�— SO-0 L Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 06)431 -3670 pproved per applicable codes. D Corrections required prior to approval. COMMENTS: \ vvvt -I' c ervi 6-4 e a O IL 'rcv rl+'u4!. "ea-, k� $5:.00 REINSPECTION FEE REQUIRED. or to inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to sechedule reinspection. Receipt No.: Date: COMMENTS: Type of Insppee lion: ('i ri//f / / 4724 »U4 — ,O k 0 - r in Pe A U S Date Called: Special Instructions: Date Wanted: 3 2Z-o G �a. , Cpl Requester: Phone No: e R se Lo c0 4_7,14.4 S'°NS yr) C'FS44r R�rPk-5 Project: ,,'4[ E.5 ci 83(3 Type of Insppee lion: ('i ri//f / Address: - r in Pe A U S Date Called: Special Instructions: Date Wanted: 3 2Z-o G �a. , Cpl Requester: Phone No: 1- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. R Corrections required prior to approval. t sp ` r, � 1 - �,�► 68.00 REINSPECTION \FEE REQUIRED. Pri aid at 6300 Southcenter Blvd., Suite 1 Date * -27 - d C to inspection, fee must be Call to sechedule reinspection. Receipt No.: 'Date: Project: / H2'Imry World path L0 1$ > Type Inspec# ion: Art / Address: Suite #: I e.. ' p G ` S Contact Person: Phone No.: Special Instructions: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 1 INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 n Approved per applicable codes. COMMENTS: F; re . eiy f c pi ne P.,f *7 a o y4 Yo .f' C /q ro SF el. /WC( Inspector: Ei.o Date:3l. Hrs.: $80.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be at 444 Andover Park East. Call to schedule reinspection. eipt No.: Date: Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit 12/2/05 po6 —o6s PERMIT NUMBERS bd Corrections required prior to approval. T.F.D. Form F.P. 85 0 , - A°rmlr N cop1r NORTHWEST e Material Han Iing Experts RACK INFORMATION SUPPLEMENT SITE ADDRESS: 18289 Olympic Ave 5. TENANT NAME: Hellmann Worldwide Logistics DATE: February 27, 2006 APPLICANT: Mike Sorenson / (206) 818 -4488 1100 SW 7th St - '►onit Renton, WA 98055 , (425) 255 -0500 ph (425) 228 -6946 fax RECEIVED CITY OF TUKWILA FEB 2 8 2006 PERMIT CENTEn CODE COMPLIANCE annnn'n:n MAR 10 2006 City Of Tukwila RI JTWTNC nn!gTflni 1. Load application and rack configuration drawings attached. 2. Attached plans detail the rack locations, dimensions, and specifications. Attached plans detail the building /ceiling configuration. 3. Stamped engineering calculations attached. 4. Vertical members of storage racks are designed and installed so that failure of one vertical member will not cause collapse of more than the bay or bays directly supported by that member. 5. Commodities stored: Component parts of medical defibrillators. Metal and plastic parts stored in cardboard boxes on 40" wide X 48" long wood pallets. Some pallets are shrink wrapped on sides only. No shrink wrap on top and bottom. 6. Sprinkler System Information: .39 GPM / 5600 square feet. Sprinkler head temperature: 165 degrees. 7. Smoke and heat vents: In place, not required for 10,000 square foot area. 8. Building egress and exits indicated on attached drawings. B G. OHANIAN BATE 2 -27 -06 SUBJECT RAdK DEOI(N & ENgINEERINd d0. 412 WE BROADWAY, BUUTE #204 {iLENDALE, OA. 91204 TEL4818)240 -3810 FAX:(818)240 -3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: FILE COPY HELMANN WORLDWIDE 11361STICS 18289 OLYMPIC AVE: SO. TUKWILA, WA. PER IBC 2003 EDITION STORAGE RACKS CAPACITY: 3000 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD -10646 REVIEWED FOR CODE COMPLIANCE Andnn.tn MAR 10 2006 aty Of Tukwila RI III MC mac - inn, SHEET NO 1 JOB NO. RD -10646 IEXPIRES 12 -26 -07 RECEIVED CITY OF TUKWILA FEB 2 8 2006 PERMIT CENTEh BY G. OHANIAN DATE. 2 -27 -06 SUBJECT BEAM 3000 #/ LEVEL +25% IMPACT LOAD 1700 #/ BEAM SEISMIC DFSIGN V= S °5 XI x w RX 1 ' 4 WORKING STRESS 1 =1 R =6 R =4 S =.8 W= D.L. +3 L.L. LONGIT. LOAD PER COLUMN LL= 3x3 K — 4.5 K 2 ca. + K W =.ta 3LI. = 3.1 .8x1x3.1 —.30x 6X1.4 V — .8x1x3.1 = 44K TRANS. 4x1.4 • RACK DESIGN & ENGINEERING CO. 412 WEST BROADWAY, SUITE #204 GLENDALE, OA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 x i 3/4' 2 3/4' IBC 2003, SEC. 2208 DOWN AISLE (MOM. CONN.) CROSS AISLE (BRACED) I =1.9 S =.9 Fy =50 /CSI S =1.2 S =1. S =2/3 S ys 1 ONf;IT. SFISMIC M= 96 "x1.7 - 20 "K 6 S 3 0 'K =.7<.9 = 5xWxL — .46" < 384xl xE USGS MAP EQ. 16 -38 EQ. 16 -40 .30x SHEET NO 2 JOB N0. RD -10646 44" 4 , 44" I 96 180 11 "x _ .5„ 1 1 .bS 1 � 1 BY G. OHANIAN DATE. 2 -27 -06 SUBJECT BEAM 3000 #/ LEVEL +25% IMPACT LOAD 1700 #/ BEAM SEISMIC DFSIGN V= S °5 XI x w RX 1 ' 4 WORKING STRESS 1 =1 R =6 R =4 S =.8 W= D.L. +3 L.L. LONGIT. LOAD PER COLUMN LL= 3x3 K — 4.5 K 2 ca. + K W =.ta 3LI. = 3.1 .8x1x3.1 —.30x 6X1.4 V — .8x1x3.1 = 44K TRANS. 4x1.4 • RACK DESIGN & ENGINEERING CO. 412 WEST BROADWAY, SUITE #204 GLENDALE, OA. 91204 TEL:(818)240 -3810 FAX:(818)240 -3813 x i 3/4' 2 3/4' IBC 2003, SEC. 2208 DOWN AISLE (MOM. CONN.) CROSS AISLE (BRACED) I =1.9 S =.9 Fy =50 /CSI S =1.2 S =1. S =2/3 S ys 1 ONf;IT. SFISMIC M= 96 "x1.7 - 20 "K 6 S 3 0 'K =.7<.9 = 5xWxL — .46" < 384xl xE USGS MAP EQ. 16 -38 EQ. 16 -40 .30x SHEET NO 2 JOB N0. RD -10646 44" 4 , 44" I 96 180 11 "x _ .5„ BY G. OHANIAN RACK DESIGN & ENGINEERING CO. DATE 2 -27 -06 412 WEST BROADWAY, SUITE #204 SUBJECT GLENDALE, CA. 91204 TEL:(618)240 -3810 FAX:(816)240 -3613 COLUMN ANALYSIS n x- t -.09" 1J COMRINED STRESS RATIO P a + M ;x= 16 +24 = .7 <1.33 RASE PLATE ANCH. TENSION — 11 (6 =.2 ANCHOR SHEAR = 2 0 = 15 K (2) -1/2 "91 HILTI KWIK BOLT 3 ESR -1385 OR EQUAL. (NO INSPECTION REQ'D) DESIGNED FOR 1/2 STRESS MOMFNT AT RFAM CON N FCTInN 'K Fy =50 Ksi A =.78 S =.80 r =1.2 r =1.1 — Z -60 I S — IL =47 y — 1.1 Max = S . Fy= 24" 2 PIN CCNNFCTOR 7/16 "0 RIVET A =.1 Fy = 79 KSI Va = .1x79x.4= 3K Ma = 3 K x4 "x 1.33 = 16 -K CONN. 2 Fe— ( K� \2 =100 r Fn — Fy(1 49e ) =42 KSI P F = 32 K P P " — 16 K ° — 1.92 — SHEET NO 3 JOB NO. RD -10646 7 3/4 "x5 "x3/8" BASE PLATE BY G. OHANIAN RACK DESIGN & ENGINEERING CO. SHEET NO 4 JOB NO. RD -10646 DATE 2 -27 -06 412 WEST BROADWAY, QUITE #204 SUBJECT 4LENDALE, CA. 01204 TEL:(818)240 -3810 FAX:(818)240 -3813 TRANSVERSE SEISMIC (OVERTURNING) M = .44 Kx2x 182 "x.5x 1.15 = 93 'K MR = 3.1 Kx42" = 130 - K NO UPLIFT I OAD TO IDIAGONAI P =.44 4 =1.2 Fy =50 KSI A =.31 r =.48 Q =.74 L= 56" C: HFC'K WFLDS 1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL) 3x.125x.707x70x.3 = 5.7 C:J4FC'K SI A9 4600 4 6' 1000 =25" • F — 1 1 .2 KSI P = 3.5 K 4.6x144 =662 a " M= ( )2x1000x 2 x12 =1500 S= 12x5 = 50 6 1500 = 30 G 1.6 2000 =72 50 TOP LEVEL LOADING M = .14 Kx2x 182"= 50 MR= 1.2 " =50 4600 ti SEC. R -8 5' CONCRETE SLAB 2000 PSI. CONC. 1000 PSF. SOIL ACTIVITY NUMBER: D06 -065 DATE: 02 -28 -06 PROJECT NAME: HELLMANN WORLDWIDE LOGISTICS SITE ADDRESS: 18289 OLYMPIC AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 8 0 6 wyj ti Buil ing Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: TUES/THURS ROUT I Please Route Structural Review Required/ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing siip.doc 2-28-02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP Fire Pr V Structural Approved with Conditions Planning Division ❑ Permit Coordinator ❑ DUE DATE: 03-02-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 03-30-06 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License NORTHWH275JF Licensee Name NORTH WEST HANDLING SYS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 600051641 Ind. Ins. Account Id 32999900 Business Type CORPORATION Address 1 1100 SW 7TH ST Address 2 City RENTON County KING State WA Zip 980552939 Phone 4252550500 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/6/1973 Expiration Date 10/9/2007 Suspend Date Separation Date Parent Company Previous License Next License NORTHHS963ND Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVS 81S103354822BCM 10/01/2001 Until Cancelled 01/01/1980 $12,000.00 10/09/2001 Business Owner Information Name Role Effective Date Expiration Date FRANCK, JAMES J 01/01/1980 THOMAS, KEVIN A 01/01/1980 KOSTY, CLARK R 01/01/1980 Look Up a Contractor, Electriri an or Plumber License Detail Page 1 of 3 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must mamtain a surety bond or assignment of account and carry general liability insurance. https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NORTHWH275JF 03/20/2006 x x