Loading...
HomeMy WebLinkAboutPermit M08-028 - WESTFIELD SOUTHCENTER MALL - PAYLESS SHOESOURCEPAYLESS SHOESOURCE 2966 SOUTHCENTER MALL M08 -028 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us 6364200010 2866 SOUTHCENTER MALL TUKW PAYLESS SHOESOURCE 2866 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA MECHANICAL PERMIT CORNEL PURAVET - FREIHEIT & HO ARCHITECTS Address: 10230 NE POINTS DR SUITE 300 , KIRKLAND WA Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA Contractor License No: IECS * * *044QL • Permit Number: Issue Date: Permit Expires On: Expiration Date: 11/20/2008 DESCRIPTION OF WORK: INSTALL MEDIUM PRESSURE DUCTWORK TO CONNECT TO CENTRAL VAV SYSTEM. INSTALL 2 NEW SERIES FAN POWERED VAV BOXES. INSTALL LOW PRESSURE DUCTWORK AND CEILING DIFFUSERS. INSTALL NEW CEILING EXHAUST FANS AND DUCTWORK TO EXISTING CENTRAL EXHAUST SYSTEM Value of Mechanical: $40,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC - 10/06 EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** M08 -028 Phone: Phone: 425 - 827 -2100 Phone: 206 939 -9495 M08 -028 05/29/2008 11/25/2008 Fees Collected: $615.33 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 05-29 -2008 Permit Center Authorized Signature: doc: I MC -10/06 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -028 Issue Date: 05/29/2008 Permit Expires On: 11/25/2008 Date: e/Z-I r VD I hereby certify that I have read and e this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied th,Ilwhether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: -7� c��°� Date: 5-v27- d Print Name: 7O/Y1 v G(A- r 5e This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -028 Printed: 05-29 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: PAYLESS SHOESOURCE 1: ** *BUILDING DEPARTMENT CONDPI'IONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2866 SOUTHCENTER MALL TUKW PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: M08 -028 ISSUED 02/05/2008 05/29/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Cond -10/06 M08 -028 Printed: 05-29 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us • 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -028 Printed: 05-29 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: 01 doc: Cond -10/06 Z e-f-ux Lk t' ✓ t° Date: A7_ G M08 -028 Printed: 05-29 -2008 Company Name: • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 ht1p:;7 "u x tt .ci.lukx ila. us Building Permit No. I 0 _ 0 '7 Mechanical Permit No. 4 O . O Plumbing/Gas Permit No. 6 08- 020 Public Works Permit No. Project No. Air office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 2$66 So vTHCENTE K l Tenant Name: ?A y LE Ss SMo65ot E Property Owners Name: W65.7 Ft E LD r L C C Mailing Address: 1 d 2 3o NF Pot NTS b E SuiTE 3oD E -Mail Address: C puro vet@ ehoQ.rck. coo-) - r. 13.1) • Contact Person: E -Mail Address: Contractor Registration Number: E -Mail Address: t 599 der h o arCH • cor" King Co Assessor's Tax No.: 636 42 DOO I O Suite Number: 21 65 Floor: 2- New Tenant: litj Yes ❑ .. No Mailing Address: 11601 WILSH(gE €LVD• %I TH FLcO LoS ANGEL.E CA GI O025 City State Zip CONTACT PERSON= who do.wecontact when your permit is ready to be issued Name: CORNEL 1ZAV e-rArCEittirir 1.1$b A9LtllTEc1,S Day Telephone: ( 5) 821— 21co KIQk1. WA quo 33 City ( State Zip Fax Number: \1t2S $ 2t. - 684 • GENERAL CONTRACTOR INFORMATION ;= (Contractor Information for (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect:of Record Company Name: F aft ttri T • NO /k at H1 TS Cr5 r I N C . s p. S P.S. Mailing Address: 102 "50 WE Put$ZS bei vE SJ %TE 30O *PAKL WA g1 o33 I City State Zip Contact Person: 10 P1 SPARE te. Day Telephone: (42 5) 321- 2 (Oo Fax Number: 1 1 2 5) 72 3 - 613R ENGINEER. OF RECORD All plans: must be wet stamped•by Engineer. of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\ApplicationsWonns- Applications On Line\3 -2006 - Permit Application.doc Revised 9 -2006 bh State Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Fumace>100K BTU Evaporator Cooler Diffuser I I 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat Z 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM . Incinerator — Com/Ind IZ e O f Ex HA u m 5T FAN 2 MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: T. Mailing Address: City state Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 4( O O 00 Scope of Work (please provide detailed information): IN STALL M EDI um PtESSut2E buCTWoRK To CoNNEcT 'TD CENTRAL VAV SYSTEM, INSTALL tWo NEW SERIES FAN PoWFRED VAV BoxES, INSTALL. NEW LOW PRESSu2E Duct wo2K AND C LG. DI FFU SE 95., INSTALL NfaW C1- ExtiAusT FANS AND but.? WORK To CONN ECT To ExlsTi/Vf cEN fl AL ExplAuST Sy STEM. Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: E XI ST I N G CE1aT 12AL VAV SYSTF M Indicate type of mechanical work being installed and the quantity below: Q:kAmlications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised. 9 -2006 bh Page 4 of 6 PERMIT. APPLICATION NOTES = Applicable to all permits in this. application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A�JTHORIZ ED GENT: Signature: � Date: Day Telephone: ( ' 8 21 ' 2100 Mailing Address: 102 3o NE PoI NTS bIZI VE 5 l't E 3oo, Ie-II2K L ARI WA 4 13 033 City ' State Zip Print Name: CORNEL. Putt "WET Date Application Expires: Date Application Accepted: c 7L— _0 9 Q: Applications\Fomu- Applications On Line 3 -2006 - Permit Application.doc Revised: 9 -2006 bh Staff Initials: Page 6 of 6 Receipt No.: R08 -01850 Initials: JEM User ID: 1165 Payee: IECS, INC. ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -028 Address: 2866 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/05/2008 Applicant: PAYLESS SHOESOURCE Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 41796 498.26 Account Code Current Pmts 000/322.100 498.26 Total: $498.26 Payment Amount: $498.26 Payment Date: 05/29/2008 12:59 PM Balance: $0.00 2968 05/29 9711 TOTAL 498026 doc: Receipt -06 Printed: 05 -29 -2008 Payee: FREIHEIT & HO ARCHITECTS ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -028 Address: 2866 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/05/2008 Applicant: PAYLESS SHOESOURCE Issue Date: Receipt No.: R08 -00320 Payment Amount: $117.07 Initials: WER Payment Date: 02/05/2008 02:38 PM User ID: 1655 Balance: $498.26 TRANSACTION LIST: Type Method Description Amount Payment Check 18520 117.07 Account Code Current Pmts 000/345.830 117.07 Total: $117.07 • rv9 8103 02/05 9710 TOTAL 1695.83 doc: Receiot - 06 Printed: 02 -05 -2008 .i)t‘'‘‘ Project: � J / S SA,o€5 Type of Inspection: .; /J / Addres / di �/ Date Called: SpecialInstructions: Date Wanted: 7 , / a.m. P.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 g Approved per applicable codes. Corrections required prior to approval. COMMENTS: f ia'( d>-- El $58.0 ' R NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid - •300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: IDate: Proj 0444/415C Type of Ins o n: Ac,resi I / C ) // Date Called: Special Instructions: Da� a nted: I ..._ J ""' (J p.m. Requester: Phone No: �-�r _ c*l� 2L im 84(t INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ✓Z 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. g Corrections required prior to approval. COMMENTS: ?re,/,./e-, a/A P A../zu.ste e Pep v1 // - i in /!4e c < (�ea.� '34./ .STS sue 1 r Date: 2/ s2 ❑ $6 s REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa • at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: - v' V1 - 1 v-R-Lki-et. 14d4ire Y10.242 \ Ls . s ✓vas p l,1!'11i' LA -e , VAt 2. c 4-uw 1n 4:. d , Ss no .2.1* - Q a s5 . S4erdoS 4.414- — CAC— --2 4... vl Project: n 1 tif ' Owes Typ of Ins ection: b mo � I...� d oow" Address: 296 L if/ALL Date Called: Special Instructions: • Date Wanted: f a.m. a.m. p.m. Requester: Phone No:? 3 "22," O %e r 5 INSPECTION NO. INSPECTION RECORD Retain $.copy with: perriiit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: ° ,- /e55 S Type of Inspection: l pi,r J,4 sa.,/ Address: /hh/ Date Called: Special Instructions: Date Wanted: a.m. 7/ .sgM Requester: Phone Nog /3 le ,EqV f INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ac t Inspector: INSPECTION RECORD Retain a copy with permit Date: 7 t11_ a� PERMIT NO. . (206)431 -3670 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: 1 Sivit5 Type of Inspection: Rov_51- hr,, , Address: 2g6't /All Date Called: Special Instructions: Date Wanted: k o - -mor gym.. p.m. Requester: Phone No: 22G " �r*3 'JL$ 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 OMMENTS: /7/1 ok 3H firA (e, pproved per applicable codes. LJ Corrections required prior to approval. Inspector: Date: 58.00 EINSPECTIO �,� - if -°V El $ N FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: COMMENTS: PA II"/'2 -, rwo A el O k ,(A f el Address: 2.44 6, Poi l 1 NV /G. i74-e T D a 0,54 Ice tLh A: r 1- . 11 4"7-- 0 No ar�il� ,', .,d ki.,. c B ..Nr,,,,, 17 s. ' Special Instructions: Date Wanted: a.m. Requester: Project: / " yL i r 54 ,c S Type of Inspection: T `u ,(A f el Address: 2.44 6, Poi l 1 Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 913 2x / Ykk a• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Pic c El Corrections required prior to approval. Inspector: - EINSPECTIO Date: 6 _ 46 _,, :g El $ 60. N FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: h Proje /9 yl; P Type o f spectio 1 /y /: , i -•v Address: G 2,55 - 6 /N4 // Date Called: Special Instructions: Date Wanted: — / 6.3.08 a.m. a Requester: Phone No: 9/ 3- 226 —ge/6,& INSPECTION NO. INSPECTION RECORD Retain a copy with permit /nCz5-av • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1/4 `fro ;45u !&- P. (co Inspector: ° Date //foie se D $6 6 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: %- / 514.0e5 T !� Type of Inspection: f 20,4 /4 Address: r �� a_f(h 6 , J Date Called: Special Instructions: Date Wanted: a.m. / / 5/4 Y p.m. Requester: • Phone No: 3 -ICJ . 419. ?995 INSPECTION RECORD Retain a copy with permit 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 feo 0.12 PERMIT NO. J (206)431 -3670 EI Approved per applicable codes. Corrections required prior to approval. COMMENTS: j )0 / ,/, 014- cave (d II ,h"-S 1,1 Inspector: 7 7 9,a te: . ,/ 3 4 4 4 ? El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: �--' /^� 5) ^o�� Type of M'e Mecl-- — o G E l L .' Je 7 i`A.)4 L t( Address: e ., g� Suite #: 5 . c_ . v2. Contact Person: Special Instructions: 9 - (110A-L - 6 t , 3 ®e- w Project: // r ttrle SS �--' /^� 5) ^o�� Type of M'e Inspection: n: c W lk .. G E l L .' Je 7 i`A.)4 L t( Address: e ., g� Suite #: 5 . c_ . v2. Contact Person: Special Instructions: Phone No.: Needs Shift Inspection: - Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER EA APproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT ea - - a - 73 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. Inspector: Date: 71 /7 / 1 , 5 g Hrs.: M $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 Fan Equipment Schedule s \ Project Address 2 $6 5O u `n-I cE Nile- 2 MALL Equip. Equip. ID Brand Name' Model No. CFM sp HP /BHP : Flow Control Location of Service t' -1 JJu`foNE NE 5 01 O 3000 Mt Nlobh t F -1 n/v`tolvE NG$6/3P `t° 3000 gA rLOoM OFFICE RECEIVE A • A • • FEB - 5 20 FILE Y,ilrsio Project Info Project Address 2 $6 5O u `n-I cE Nile- 2 MALL Date .. _ S -08 1 k lAe (L A w� r For Building Dept. Use Total CFM Applicant Name: c62NEL poKALET / F/- €r l T t Nv Aatc/s ncS Applicant Address: I 6-2 , ),)e_ min-Ts be-A/5- S✓F'TE ,t z , Applicant Phone: 4e F&. WL A P-b, ,'-A ( 212"t -2 row Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location viw-I `tt Ivs A -T FS- 6 3000 0FtcE VAv-2 -t 1 v ATFS- [ 3000 OFFICE CM FILE Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or�ny �'" F j�nput Btuh 1,Q�P 1 u��^ St h Efficiency 4 * C a 4&� ..�Aa ., 0 -" IN Cto CITY OF TUKWILA - BUILDING DIVISION 21306 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. lEdes Plans INSTALL HI bj of \ p2essu1f bvcT (A..OKV ' coN A/G i CE,.J AL V, ' ' # n i I/ simtL T w o VS LA S 1 po ' r /2ED VAV I E-- ( NS ?A LC ►./ 6w L-O ' Q12FSSv g ANr L EI LT & G 11JMALL. Nc -wce_; Lt NG ExrfAuisT `FANS AN`b bi.,c' 1.4-62K rft PfrE c -ra C K)S ?. Include documentation requiring compliance with commissioning requirements, Section 1416. F�N>q ✓ Sir sys� Compliance Option Simple System 0 Complex System Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: Constant vol? Split system? • • Air cooled? • Packaged sys7 • <20,000 Btuh? Economizer included? • • If Heating Only: <5000 cfm7 <70% outside air? • • CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Surnmaey (back) MEH -SUM Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only otal Ca +. wo economize <240,000 Btuh or 10 %? No Yes — ( \ Reference Section 1421 Heating /Cooling or Cooling Only Simple System Allowed (section 1420) r Reference Section 1423 Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. sT: - 80 fri Use Complex Systems (section 1430) Mechanical Permit Plans 1 2006 Washington State Nonresidential Energy Code Compliance Forms Checklist MECH -CHK � . ii l Revised July 2007 Project Address 'Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required I Location on Plans I Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary 1414.2 Duct insulation Indicate R -value of insulation on duct 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER - HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washin 'Mechanical Permit' Plain CheciClist l II I' I. 2006'Washington State', Nonresldential Code Compiiance'Forms Revlsed�lluly';j'07i r en a on on 9 ec anica enera equiremen ton State Nonresidential Ener 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a produ ct covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including !power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Sery Ice Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and co oling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the'proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. Code Corn Iiance.,Form i ro s or • ccupancy yeas: • ema • con ro ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An, air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mech anical cooling. Water economizers shall be capable of providing the total concurrent cooling , load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculati on, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air- cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have aerated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. Water - cooled water chillers with waterside economizer. 2. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be 'provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 -320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS- 18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washin 'Mechanical Permit' Plain CheciClist l II I' I. 2006'Washington State', Nonresldential Code Compiiance'Forms Revlsed�lluly';j'07i r en a on on 9 ec anica enera equiremen ton State Nonresidential Ener 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a produ ct covered in Tables 14 -1A through 14 -1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including !power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Sery Ice Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and co oling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the'proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. Code Corn Iiance.,Form i ro s or • ccupancy yeas: • ema • con ro ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An, air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mech anical cooling. Water economizers shall be capable of providing the total concurrent cooling , load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculati on, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air- cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have aerated capacity less than 65,000 Btu/h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. Water - cooled water chillers with waterside economizer. 2. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be 'provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 -320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS- 18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated 2. Combustion air intakes. 2006 Washington State Nonreside " Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btulh shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. ntt E Alat9yCCi i�Glt cre lisces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) DEPARTMENTS: ' tl v g HL-21! B Ilding Division Public Works Complete TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -028 DATE: 02 -05 -08 PROJECT NAME: PAYLESS SHOESOURCE SITE ADDRESS: 2866 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued ( Awc. 21 -o6 Fire Prevention 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Structural Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: ❑ Permit Coordinator DUE DATE: 02 -07 -08 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: ❑ No further Review Required DATE: DUE DATE: 03 -06 -08 Not Approved (attach comments) n DATE: Planning Division Not Applicable Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License IECS * * *044QL Licensee Name IECS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601639846 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 19252 Address 2 City SEATTLE County KING State WA Zip 981091252 Phone 2064694153 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 UNUSED Effective Date 11/13/1996 Expiration Date 11/20/2008 Suspend Date Separation. Date Parent Company Previous License Next License SEATTMI038NR Associated License Business Owner Information Name Role Effective Date Expiration Date HUMPHREY, GEORGE 01/01/1980 Look Up a Contractor, Electr or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information S Savings Information Savings Bank Name Bank Branch Location Assignment of Savings Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date Page 1 of 3 https:// fortress .wa.gov /lni/bbip /printer.aspx ?License =IECS* * *044QL 05/29/2008 SERIES FAN POWERED VAV FAN TERMINAL UNIT SCHEDULE EQUIP ID LOCATION TYPE PRIMARY AIR DAMPER FAN DIMENSIONS FILTER [3] NC LEVELS [2] ELECTRIC HEATING COIL BASIS OF DESIGN REMARKS PFT = PARALLEL, SFT = SERIES MAX FLOW: CFM MIN FLOW: CFM MAX PD: IN. WG FLOW: CFM ESP: IN. WG [1] MOTOR: HP VOLTS/ PHASE INLET: DIA IN. OUTLET: W x H IN. MAX FACE VEL: FPM MAX DISCHARGE: NC MAX RADIATED: NC CAP: KW VOLTAGE PHASE MANU- FACTURER MODEL VAV-1 OFFICE SFT 3000 450 0.5" 1700 0.3 3/4 120/1 14 16X14 150 44 39 15.2 480 3 TITUS ATFS —E DUCT SMOKE DETECTOR VAV -2 OFFICE SFT 3000 450 0.5" 1600 0.3" 3/4 120/1 14 16X14 150 44 39 12.0 480 3 TITUS ATFS —E GENERAL NOTES: AND ASSEMBLIES SHALL BE U.L. LISTED. EXTERNAL TO TERMINAL UNIT. DOES NOT INCLUDE ALLOWANCE FOR FILTER LOADING. USING MODELING ASSUMPTIONS BASED ON ARI 885 -90, 1" INLET SP, 0.25" DOWNSTREAM SP AND 1" FIBERGLASS INSULATION. BE 1 -INCH, PLEATED DISPOSABLE TYPE, 20 -20 % EFFICIENCY (ASHRAE 52.1), UL LISTED. ELECTRICAL EQUIPMENT NOTES: 1. STATIC PRESSURE 2. NC VALUES CALCULATED 3. FILTERS SHALL LEGEND SYMBOL ABBREVIATION DESCRIPTION TOILET ROOM G NATURAL CAS -- 0 — ® T'SFAT THERMOSTAT FOR RBADIE SENSOR ® — REMOTE SENSOR 90 rrr 0.2" DUCTWORK WRH TURING VME --- R_A: FLEX CONK. --J VD %DUNE DAMPER 1 WESC?1-ITM HARD DUCT REMARKS (1)(2)(3) — FLEXIBLE DUCT -- ROOM SPIN -IN WITH V.D. III CD CEILING DIFFUSER ■ RG RETURN GRILLE 0 -- AIR DISTRIBUTION SCFED./NO. 7 0 -- PLAN NOTES /LETTER A M -- DUCT SMOKE DETECTOR EXHAUST FAN SCHEDULE DESIGNATION EF - 1 ZONE TOILET ROOM MANUFACTURER: NUTONE MODEL: NE8673P TYPE CEILING DRIVE DIRECT CFA 90 E.S.P. ON-H20); 0.2" RPM --- R_A: 0.5 VOLTAGEg 120 PHASE: 1 WESC?1-ITM - -- REMARKS (1)(2)(3) (1) SOURCE SPECIFIC FAN "AMCA" APPROVED. (2) CONTROLLED WITH LIGHT SWITCH. (3) WITH 60 WATT LAMP, PLAN INDEX M-1 GENERAL NOTES, SCHEDULE AND LEGEND M-2 HVAC PLAN GENERAL MECHANICAL CONDITIONS 1) 2) ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3) THIS CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER SUPPLY DIFFUSERS, RETURN GRILLS, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THIS CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LOCAL LAWS, ORDINANCES, RULES AND REGULATIONS. 4) DRAWNGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAILS. 5) THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6) THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 7) THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS AND ALL OTHER TRADES. 8) THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9) STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT/OWNER. 10) CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THIS CONTRACTOR SHALL BE REMOVED FROM PREMISES AS OFTEN AS NECESSSY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA. 1 1) ALL WORK AND EQUIPMENT IS TO BE FULLY GUARANTEED FOR ONE ( 1 ) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE, EXCEPT FOR CARRIER HVAC COMPRESSORS WHICH SHALL CARRY A FIVE (5) YEAR GUARANTEE ON COMPRESSORS AND (10) YEAR ON HEAT EXCHANGERS. 12) ALL WORK, INCLUDING INSIDE OF AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 13) CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14) INTERRUPTION OF HEATING, POWER AND AUXILIARY SYTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES. 15) ALL WORK SHALL INCORPORATE CURRENT ASHRAE METHODS AND SHALL MEET LOCAL SEISMIC SUPPORT AND BRACING REQUIREMENTS. MECHANICAL SPECIFICATIONS 1) 2) 3) 4) 5) THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. AIR BALANCE A) HVAC CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST & TEST EOUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO P.S.S. PROJECT MANAGER FOR REVIEW. (VERIFY WITH LANDLORD). DUCTWORK A) INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WTH RECOMENDED CONSTRUCTION FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS, CHAPTER 6 OF THE 2003 -IMC AND ALL OTHER AUTHORITIES HAVING JURISDICTION. 8) PROVIDE ALL MATERIALS COMPLYING WITH NFPA BULLETIN 90 -A, AS DETERMINED BY U.L. METHOD NFPA 225 -ASTM E84, AND COMPLYING WTH THE GOVERNING CODE WITH FLAME SPREAD RATING UNDER 25 AND SMOKE DEVELOPED RATING UNDER 50. ALL DUCT JOINTS SHALL BE SEALED USING DUCTSEAL AS MANUFACTURED BY UNITED SHEET METAL OR EQUAL. C) STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED FIVE (5) FEET FOR EACH DIFFUSER. D) ALL RECTANGULAR SUPPLY AND RETURN DUCTWORK SHALL BE EXTERNALLY INSULATED AND /OR SOUNDUNED WITH A MINIMUM THICKNESS THAT CONFORMS TO THE STANDARD OF THE GOVERNING CODE AND SHALL IN NO CASE HAVE LESS THAN R- 3.3/R -8 THERMAL RESISTANCE (HEATED /UNHEATED). ALL AIR OUTLETS SHALL HAVE VOLUME DAMPERS. E) ALL ROUND GALVANIZED STEEL AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE INSULATED WITH FIBERGLASS DUCT WRAP WITH VAPOR BARRIER AS STANDARD. ROUND DUCT SIZES INDICATED ON THE DRAWINGS ARE INSIDE "FREE AREA" DIMENSIONS. F) PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EOUIPMENT AND CONNECTING DUCTWORK. G) HVAC SHALL PROVIDE AND INSTALL FIRE DAMPERS WHEN THE DUCT PENETRATES THROUGH FIRE RATED STRUCTURAL MEMBER. AIR DEVICES A) SUPPLY DIFFUSERS SHALL BE FURNISHED AS DESCRIBED ON DRAWINGS WITH BAKED WHITE ENAMEL FINISH, AND SHALL BE SELECTED FOR NOISE LEVEL NC -35 OR LESS. B) SUPPLY DIFFUSERS SHALL BE ROUND NECK, STEEL, FOR LAY -IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL CEILING AS INDICATED ON DWG. C) RETURNS & EXHAUST AIR DEVICES SHALL BE AS DESCRIBED ON DRAWINGS WITH NOISE LEVEL NC -35 OR LESS. D) COORDINATE LOCATION OF AIR DEVICES WTH LIGHTS, SPRINKLERS, SPEAKERS, SMOKE DETECTORS, ETC. EQUIPMENT A) REFER TO MECHANICAL PLANS FOR SPECIFICATIONS OF HVAC EQUIPMENT. B) ALL NEW EQUIPMENT WLL BE EQUIVALENT TO THE SPECIFIED ITEM. ANY ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILTY OF THIS CONTRACTOR. C) MOUNT NEW EQUIPMENT USING VIBRATION MOUNTS OR HANGERS, MOST SUITABLE FOR THE APPLICATION. D) ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. E) PROVIDE TRAPPED CONDENSATE DRAINS FOR COOLING EQUIPMENT. DRAIN TO BE DISCHARGED ON ROOF, UNLESS LANDLORD SPECIFIES DIFFERENTLY. F) COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS. CONTROLS A) PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON AN INDIVIDUAL BASIS. B) THIS CONTRACTOR TO PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, TEST AND START -UP. C) COORDINATE INTERFACING OF DUCT MOUNTED SMOKE DETECTOR (WHEN SPECIFIED OR REQUIRED WITH ELECTRICAL CONTRACTOR TO STOP FAN). CONTROL: A) H.V.A.C. UNITS: THERMOSTAT: PSS SHALL PROVIDE AND CONTRACTOR SHALL INSTALL ONE (1) CARRIER DEBONAIRE 250 CUSTOMIZED THERMOSTAT (PSS #33CS250 -PL) AND MATCHING REMOTE SENSOR (CARRIER MODEL #33CSSEN --01) FOR EACH ROOFTOP UNIT. MOUNT THERMOSTATS AS INDICATED ON DRAWINGS. MOUNT REMOTE SENSOR IN SALES AREA AS INDICATED ON DRAWINGS. NOTE: COORDINATE WITH LANDLORD PRIOR TO CONSTRUCTION TO ASSURE THE PROPOSED CONTROL SYSTEM IS IN COMPLIANCE WITH LANDLORD'S BUILDING STANDARDS AND MAKE PROVISIONS FOR INTERFACE TO LANDLORD'S SYSTEM AS REQUIRED. INSTRUCTION TO BIDDERS 1. VERIFY WITH OWNER AND GENERAL CONTRACTOR FOR OWNER FURNISHED ITEMS PRIOR TO BIDDING /CONSTRUCTION. 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACTOR SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS, 3. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 5. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING IN ORDER TO ESTABUSH EXISTING CONDITIONS AND NEW DESIGN REQUIREMENTS. THE CONTRACTOR SHALL INCLUDE IN THE BID ALL REQUIRED EQUIIPMENT, ACCESSORIES IN ORDER TO INSTALL A COMPLETE MECHANICAL SYSTEM READY FOR THE OWNERS BENEFICIAL USE. THE CONTRACTOR SHALL INCLUDE IN THE BID AU.. ITEMS NOT SHOWN IN THE DESIGN DRAWINGS IN ORDER TO MEET THE INTENT OF THIS DESIGN. MAINTAIN 1 2' OF STRAIGHT FLEX DUCT BEFORE CONN. TO DIFFUSER STRAIGHTENING GRID NOTES: IN LIEU OF ABOVE DETAIL METAL PLENUM MAY BE USED TO CONNECT THE BRANCH DUCT TO THE DIFFUSERS. ELBOW R /D =1.5 NO SCALE .IIIIIIIIIIIIIIIIIIIIIL DIFFUSER CEILING DIFFUSER DETAIL USE A 5 -PIECE DUCTBOARD 917 ELBOW OR SMOOTH SHT. MTL) WHERE 12 STRAIGHT IS NOT FEASIBLE FLEX DUCT ADAPTER WHERE APPLICABLE CEIL"G (COORD. WITH ARCH') FRAME TO SUIT CLG. (fYP.) ENERGY CODE NOTES: 1) THERMOSTATS SHALL BE A 7 DAY PROGRAMMABLE TYPE WITH A 5 DEGREE DEADBAND AND AUTOMATIC SETBACK CONTROL PER 1412.2 WASHINGTON STATE ENERGY CODE. 2) HVAC EQUIPMENT SHALL MEET THE MINIMUM ENERGY EFFICIENCY RATINGS PER TABLE 14 -1, 14 -2 AND 14 -3 OF THE WASHINGTON STATE ENERGY CODE. 3) DUCT INSULATION AND SEALING SHALL MEET CHAPTER 14 SECTION 1414 REQUIREMENTS. 4) SUPPLY AND RETURN DUCTS IN UNCONDITIONED SPACES SHALL BE INSULATED TO MIN. R -8. ROOFTOP HVAC DUCTWORK SHALL HAVE A WEATHER BARRIER. 5) SUPPLY AND RETURN DUCTS IN CONDITIONED SPACES SHALL BE INSULATED TO MIN. R -4. UNCONDITONED SPACES SHALL BE R -8. 6) PIPING INSULATION SHALL MEET THE REQUIREMENTS OF WASHINGTON STATE ENERGY CODE TABLE 14 -6. 7) CONTRACTOR SHALL SUBMIT RECORD DRAWINGS AND OPERATING AND MAINTENANCE MANUALS PER 1416 WSEC. 8) CONTRACTOR SHALL PERFORM AND SUBMIT AN AIR BALANCE REPORT PER 1416.3.1 PER WSEC. 9) CONTRACTOR SHALL PERFORM COMMISSIONING AND SUBMIT A COMMISSIONING REPORT AND DOCUMENTATION PER 1416.4 PER WSEC. SEPARATE PERMIT REQUIRED Mec hanical Electrical 1: ' lambing Gas piping CITY D� BUILDING StCN DUCTBOARD BOOT, INTERIOR PAINTED BLACK NO CALF NO SCALE DIMENSION OF GRILLE f I$• FRAME TO SUIT CEILING TYPE (VERIFY WITH ARCH'L) GRILLE MIN PLENUM EXTENSION TO REDUCE NOISE TRANSFER -.--N-0 (AREA =300 FPM MAX.) DROP. CEIL CEILING RETURN GRILLE DETAIL M -1 �•- -=,•) • - per+ ,h 3 ' „`,,, COI • No changes shJII to the scope of work w:tsr.0 4. Tukwila B . iity g NOTE: Revisions Wilt equire a new Pf submittal and may include additional plan review tom. FILE COPY Permit No. Plar review approval is subject to errors and Approval of construction documents does not auitionze the violation of any adopted code or ordnance, of approved Field Copy and conditions la By ,2 Date: og City dT BUILDING DPMC114 k110 8o28 RECEIVE; FEB - 5 2008 PERMIT CENTEk PERMIT SET 01 -07 -08 R e v i s i o n s Date DeecrIItIcn FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SUITE 300 IO1MD, WA 98093 N253272100 F.425J328,6899 STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 General Notes, Specification, Schedule & Legen M1 OF 2 DRAWN BY: JW SH ABOSSIIN NO: #27229 DATE: 01 -07 -08 PROJECT NO.: A07-659 AIR DISTRIBUTION SCHEDULE TYPE DESCRIPI1ON CFM NECK SIZE TITUS MODEL REMARKS A T -BAR DIFFUSERS PER PLAN PER BELOW TMSA 4 -WAY THROW B SOLID CEILING DIFFUSERS PER PLAN PER BELOW TMS C CLG. RETURN /EXH. GRILLES PER PLAN PER BELOW 50F3 D T -BAR RETURN /EXH. GRILLES PER PLAN PER BELOW 50F3 ADJUSTABLE BLADES DUCT SIZE FEEDING THE AIR DISTRIl3LTrION NECK NECK NECK SIZE (ROUND) CFM (MIN.) CFM (MAX) TYPE- A (MOD) TYPE- B (TMS) TYPE- C (50F3) 4" 0 35 6 "RD 6 X 6 5" 36 60 6 X 6 6 "RD 6 X 6 6" 61 95 6 X 6 6 "RD 6 X 6 7" 96 145 6 X 6 6 "RD 8 X 6 8" 146 200 8 X 8 8 "RD 10 X 6 9" 201 280 10 X 10 8 "RD 10 X 6 10" 281 380 10 X 10 12 X 10 12" 381 600 12 X 12 18 X 10 14" 601 900 24 X 12 16" 901 1300 24 X 18 18" 1301 1750 24 X 24 20" 1751 2300 24 X 24 NOTES: 1) CEILING DIFFUSERS, REGISTERS AND GRILLES SHALL BE TITUS OR EQUAL. 2) CD= CEILING DIFFUSER, RG= RETURN GRILLE, TG= TRANSFER GRILLE. 3) FASTENING METHOD SHALL BE AS SELECTED BY ARCHITECT AND SHALL BE COMPATIBLE WITH THE WALL OR CEILING STRUCTURE THAT IS BEING INSTALLED TO. COORD. AT SITE T• R U AND CONNECT TO LAND OR PROVIDED CENTRAL EXIT ST SYSTEM • 11 11. MMEMOW ti\ m \ W1. MNIMM f \\ \� \ it \ r1 M \ \1 'I� TER OUTLET U T, tf Y p. TOILET 130CFM -A PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection I f I 4i OCh M -A 400CF,1 -A - r ri 24X12 TYPE "0" I RUB EIS OPE s�LNU�id B =a; 1\"' \"�1 \ \ \ \\w\\.h -ia_AI'v_vomb. \ \ \L� \ \\ Iwomei \\` \ \`� Li m..io\ 1 \\` \ \!: \ \�k�t\ ~i\.. ►��\ "\"' \` ` \ \� \\\ \ \� r1��� \ \" \w.. \.\ \tom \ \\ 1\h� wa \\ \` \, iii ii- i \ \i� ia"'.' �'!:_itt�i�mh.\.�i iii "lii��` `�tiiitl�►i` `4"11��i,1 ,,,,. ,.i \i∎i�4l` ".RiiN 4 i` 4ii .ii \iii 'r'.►i` .1... i. -t.o � \i \_ \i\ .i 400CFM -B MALL EGRESS PASSAGEWAY ALCOVE 14" 14" TRANS. FRO TO ROUND FLOOR PLAN—HVAC SCALE: 1/ 77 GENERAL NOTES: 1) COMPLETE INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE PER THE STATE OF WASHINGTON BUILDING, MECHANICAL ENERGY, FIRE, PLUMBING AND HEALTH CODES AND REGULATIONS AS ADOPTED BY THE LOCAL JURISDICTIONS. 2) ALL EQUIPMENT SHALL BE THE CAPACITY AND TYPES AS SHOWN ON THE EQUIPMENT SCHEDULE AND SHALL BE THE LISTED MANUFACTURER AND MODEL NUMBER. 3) THE CONTRACTOR SHALL SUBMIT MINIMUM OF SIX COPIES OF EQUIPMENT SUBMITTALS FOR APPROVAL 4) CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE REQUIRED FOR A COMPLETE MECHANICAL SYSTEM AND AFFECT HIS CONTRACT PRIOR TO ENTERING AND SIGNING THE CONTRACT; AFTER AWARDING THE CONTRACT ALL SUCH ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE, AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES. MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE STANDARDS WITH THE ARCHITECT /ENGI NEER'S APPROVAL 5) ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE, AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPUED OR STATUTORY. NO WARRANTY OF MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY. (THE WARRANTY SHALL START FROM THE TIME OF TENANT /ENGINEERS FINAL ACCEPTANCE.) PROVIDE TENANT WITH FIVE (5) YEAR WRI I I EN WARRANTY INCLUDING LABOR AND PARTS ON AIR CONDITIONER COMPRESSORS, TEN (10) YEAR WARRANTY INCLUDING LABOR AND PARTS ON GAS -FIRED HEAT EXCHANGERS AND ONE (1) YEAR WRITTEN WARRANTY ON COMPLETE INSTALLATIONS. PROVIDE TENANT WITH OPERATING INSTRUCTIONS ON ALL EQUIPMENT. 6) ENTIRE INSTALLATION OF ALL EQUIPMENT, CONTROL, PIPING, DUCTWORK AND RELATED ACCESSORIES SHALL BE PER BASIC BUILDING STANDARDS. MECHANICAL CONTRACTOR IS TO FAMILIARIZE HIMSELF WITH THESE STANDARDS. REFER TO BASIC BUILDING SPECIFICATIONS, DRAWINGS AND AMENDMENTS WHERE APPUCABLE. 7) COORDINATE WITH THE STRUCTURAL ENGINEER TO PROVIDE STRUCTURAL SUPPORT FOR ROOF TOP EQUIPMENT AS APPROVED BY THE LOCAL JURISDICTIONS. 8) MECHANICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY THE ROUTING AND INSTALLATION FEASIBILITY OF ALL EQUIPMENT, PIPING AND DUCTWORK PRIOR TO SUBMITTING HIS BID AND INCLUDE IN HIS BID ADDITIONAL PIPING, DUCTWORK, FITTINGS, OFFSETS, ETC. WHICH MIGHT BE REQUIRED FOR A COMPLETE SYSTEM READY FOR OWNER'S BENEFICIAL USE. 9) COORDINATE THE CONSTRUCTION SCHEDULE WITH THE TENANT /LANDLORD AND PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH THE TENANT /LANDLORDS' SCHEDULES. 10) MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE AUTHORITIES HAVING JURISDICTION. 11) ADJUST ALL EQUIPMENT AND PERFORM A COMPLETE AIR - BALANCING AND PUT ALL MECHANICAL SYSTEMS IN OPERATION. 12) 13) 14) THE MECHANICAL CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT AIR BALANCE AND TESTING AGENCY, TO BALANCE, ADJUST, AND TEST AIR MOVING EQUIPMENT, AND AIR DISTRIBUTION AND EXHAUST SYSTEMS. THE TESTING AND BALANCING FIRM SHALL BE CERTIFIED BY NEBB OR AABC AND ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THESE ORGANIZATIONS' PUBLISHED PROCEDURE MANUALS. THE BALANCING AGENCY SHALL PREPARE A CERTIFIED REPORT OF ALL TESTS PERFORMED. THE REPORT SHALL BE WRITTEN ON STANDARD FORMS PREPARED BY NEBB OR AABC OR FACSIMILES THEREOF. THE BALANCING AGENCY SHALL SUBMIT 3 COPIES OF THIS REPORT TO THE MECHANICAL CONTRACTOR WHO SHALL SUBMIT THEM TO THE "PSS" PROJECT MANAGER FOR REVIEW AND DISTRIBUTION, INCLUDING TO "PSS" CORPORATE CONSTRUCTION SERVICES. THIS REPORT AND ABOVE DESCRIBED WARRANTIES MUST ACCOMPANY THE CONTRACTOR'S REQUEST FOR FINAL PAYMENT. SUBMIT COPY TO MALL OPERATIONS. NOT USED. NOT USED. NOT USED. TYP. TYP. 15) HVAC NOTES: A) PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING TO AIR MOVING EQUIPMENT AS CLOSE TO FAN AS POSSIBLE. FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR MORE OF AIR TIGHT, FIRE PROOF FLEXIBLE NEOPRENE COATED WOVEN FIBROUS GLASS MATERIAL. VENT FABRICS, INC. OR APPROVED EQUAL B) ALL DUCTWORK SHALL BE SHEET METAL. SOUNDUNE SUPPLY & RETURN DUCTS WITHIN 10 FEET FROM THE UNIT OPENINGS (MIN. THERMAL RES. OF R -3.3 @ 75 DEGREES MEAN TEMP.). INSULATE ALL SHT. MIL. DUCTS WITHOUT SOUNDUNING WITH MIN. 1" (MIN. THERMAL RES. OF R -3.3 ® 75 DEGREES MEAN TEMP.) WITH VAPOR BARRIER JACKET. ALL DUCTWORK EXPOSED TO OUTSIDE TEMPERATURE TO HAVE ADDITIONAL 1" SOUNDLINING FOR TOTAL OF MINIMUM 2" SOUNDUNING AND MINIMUM R -7 THERMAL VALUES. C) ALL SUPPLY & RETURN FLEXIBLE DUCTS SHALL BE CONSTRUCTED OF DOUBLE LAMINATION OF POLYESTER ENCAPSULATED STEEL WIRE HEUX FOR INNER CORE HIGH DENSITY FIBERGLASS INSULATION AND GRAY POLYESTER FILM WITH SPIRAL REINFORCEMENTS EQUAL TO "ATCO --70 SERIES" (MIN. POS. PRESS. = 6" W.G., NEG. PRESS = 0.75" W.C. & R= 5.79). D) NOT USED. E) PROVIDE LOCKABLE VOLUME DAMPERS IN ALL AIR DISTRIBUTION OUTLETS. F) DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION SHALL CONFORM TO ASHRAE & SMACNA RECOMMENDATIONS. G) DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA. H) ALL DUCTWORK SHALL BE CLASS -I AIR DUCT AS APPROVED BY U.L - 181. I) ALL DUCTWORK IN UN- HEATED SPACES SHALL BE INSULATED WITH MINIMUM THERMAL RESISTANCE VALUE OF R -7. ( SOUNDLINING THERMAL VALUES MAY BE DEDUCTED FROM TOTAL R -7). 16) NATURAL GAS: NOT USED. 17) NOT USED. 18) THE CONTRACTOR SHALL NOT OPERATE THE EQUIPMENT FOR TEMPORARY HEATING OR VENTILATION DURING THE CONSTRUCTION. (ALL EQUIPMENT SHALL RUN FOR TESTING AND BALANCING PURPOSES ONLY). NOTIFY THE ENGINEER 48 HOURS (MINIMUM) IN ADVANCE TO ARRANGE A FINAL FIELD INSPECTION PRIOR TO COVERING UP THE CEIUNG. 19) SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK, INSTRUCTION TO BIDDERS AND EXACT LOCATION OF ALL FIXTURES. 20) COORDINATE EXACT LOCATION OF ALL EQUIPMENT AND PENETRATIONS WITH THE ARCHITECTURAL STRUCTURAL AND AT SITE. 21) ALL APPUCABLE CODES AND LOCAL JURISDICTION REGULATIONS SHALL SUPERSEDE THE CONSTRUCTION DOCUMENTS IF THEY ARE MORE STRINGENT. 22) PIPE HANGERS AND SUPPORTS: PIPE HANGERS AND SUPPORTS SHALL BE IN STRICT ACCORDANCE WITH THE "UPC ", "IMC" AND PIPE MANUFACTURERS RECOMMENDATIONS. ALL PIPES SHALL BE SEISMICALLY RESTRAINED PER LATEST EDITION OF S.MAC.NA SEISMIC RESTRAINT MANUAL AND AS REQUIRED BY LOCAL JURISDICTION. 23) ALL MATERIALS USED SHALL BE NEW AND BEAR U.L LABEL WHEN REQUIRED. 24) FINAL AS BUILT DRAWINGS SHALL BE SUBMITTED TO TENANT /ENGINEER. 25) ALL OPENINGS AND PENETRATIONS THROUGH ROOF AND /OR WALLS SHALL BE PROPERLY SEALED, WEATHERTIGHT, AND AESTHETICALLY ACCEPTABLE. 26) ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF NEW EQUIPMENT, FIXTURES AND PIPING TO BE BY CONTRACTOR. 27) ALL ROOF PATCHING TO BE BY LANDLORD APPROVED CONTRACTOR AT TENANTS EXPENSE. ADJACENT TENANT (E 3 KEYED NOTES: A) 1" SOUNDLINED SUPPLY DUCT, TRANSITION TO UNIT OPENING. B) COORD. AT SITE TO MAINTAIN CLEARANCES PER NEC FOR FAN AND HEATER CONNECTIONS, TYP. C) COORD. AT SITE TO ROUTE AND CONNECT TO LANDLORD PRIVIDED PRIMARY AIR STUB -OUT, VERIFY EXACT LOCATION AT SITE. D) CEILING RETURN GRILLE, SEE DETAIL ON SHT. "M -1" (TYP.) E) G) H) I) J) K) CEILING DIFFUSER, SEE DETAIL ON SHT. "M-1" (TYP.) F) VERIFY Sc COORD. EXACT LOCATION AND ROUTING OF DUCTWORK WITH STRUC'L., CLG., LIGHTS AND AT SITE (TYP.). MAXIMUM 6 FEET LONG FLEXIBLE DUCT (TYP.). ALL DUCT BRANCHES TO HAVE VOLUME DAMPERS, (TYP.). SEE AIR DIST. SCHEDULE, THIS SHT. (TYP.). DUCTWORK ABOVE CLG. (TYP.) REMOTE SENSOR FOR 7 -DAY PROGRAMMABLE THERMOSTAT ® 66" AFF.. L) INSTALL THERMOSTATS FOR REMOTE SENSORS AT 48" A.F.F. AND LOCATE PER PAYLESS OFFICE STANDARD. DIFFUSERS ABOVE SOLID CLG. SHALL O HAVE OBD FOR BALANCING, TYP. ' REV '' " ' s� F OR. CE CODE COMPL T ^ C A 'E LL. ' Dl JI L , i , C "'A FEB — 5 2008 PERMIT CENTER PERMIT SET 01 -07 -08 R e v i s i o n s Date 2-1-08 Description LANDLORD COMMENTS • itr FREIHEIT at HO ARCHITECTS, INC., P.S. =ONE lE PoNls DRIVE SUIRE 300 MAK WA MEG 1415.8272100 F:425.8284899 STORE NO. 4307RL PAYLESS 2866 SOUTHCENTER MALL TUKWILA, WA 98188 HVAC Floor Plan M2 OF 2 DRAWN BY: .JH SH ABOSSEIN NO: #27229 DATE: OI -07 -08 PROJECT NO.: A07 -651