Loading...
HomeMy WebLinkAboutPermit M08-030 - WESTFIELD SOUTHCENTER MALL - DUKE'S CHOWDER HOUSEDUKE'S CHOWDERHOUSE 757 SOUTHCENTER MALL M08 -030 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Value of Mechanical: $23,327.00 Type of Fire Protection: doc: IMC -10/06 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 757 SOUTHCENTER MALL TUKW DUKE'S CHOWDER HOUSE 757 SOUTHCENTER MALL , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA KENDY CARROLL 20838 SE 240 ST , MAPLE VALLEY WA Contractor: Name: SEA -TEMP Address: 20838 SE 240 , MAPLE VALLEY, WA Contractor License No: SEATE * *971C4 DESCRIPTION OF WORK: INSTALLATION OF WALK -IN COOLER /FREEZER, REFRIGERATION INSTALL. Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 0 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * * continued on next page ** M08 -030 Permit Number: M08 -030 Issue Date: 03/03/2008 Permit Expires On: 08/30/2008 Phone: Phone: 206 265 -9061 Phone: 206 870 -8367 Expiration Date: 02/24/2009 Fees Collected: $430.93 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 03 -03 -2008 Permit Center Authorized Signature: / '\ I hereby certify that I have read and $x governing this work will be complied doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -030 Issue Date: 03/03/2008 Permit Expires On: 08/30/2008 /411 Date: 0 4 f n ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit. Signature: fri, k_t (Thr'O , t_p Date: 3/ ,3 /c) g Print Name: 1/- r-nCt Co r f-v l 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -030 Printed: 03 -03 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 757 SOUTHCENTER MALL TURN/ DUKE'S CHOWDER HOUSE 1: ** *BUILDING DEPARTMENT COND1'I'fONS * ** PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: ** *FIRE DEPARTMENT CONDITIONS * ** M08 -030 ISSUED 02/06/2008 03/03/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4)(Extend sprinkler protection to walk -in cooler and freezer.) 13: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) M08 -030 Printed: 03 -03 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -030 Printed: 03 -03 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us er1dA q C .Q 13c)(Aclui CcuvmlI doc: Cond -10/06 M08 -030 Date: 3 I J / d ordinances governing or local laws regulating Printed: 03 -03 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: 'ivwn.ci.tukivila.iva.us ONTACT PERSON who d Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION n King Co Assessor's Tax No.: ( 1 ` l/0 001() Site Address: 7 S1 3a 1 1 h Q M I 9 s i gs Suite Number: Floor: Tenant Name: 1 1 ) ' ■_ , ‘ \<PS CI Il(\t t Y t (.e( 1 \ } S( New Tenant: II Yes ❑ ..No Property Owners Name: rr , kt. M( .x \ p \ Mailing Address: 1 S `J . GI r n 1 t h , . ectt- i Q. (,13 — q o Zip City Name: C \e M1a C(Y � 1 + Day Telephone: ,(,)(n `` , (r C IO (e I Mailing Address: 9O 3X �E a4- 4 J L Wi �. a o∎ - C? gd 8/ City I State Zip E -Mail Address: 00 MP e_ NICk � 1 . (C) r Fax Number: 7 2 - f-:3D- c5 4 K GE iERAL CON' {Mon tt^ ORM:TTC?N . 4) f Plumes and �>l Company Name: L )ea – T XYi ( y Mailing Address: c ()S 3 JE 4l`;k k St M A lin Its SO\ - 9RO' (� i1 City State Zip Contact Person: l � 1 � `` ' ,, I ,, � 11�� V i �1(J� Day Telephone: P 2 S 8 3 "7 E -Mail Address: 9'( k pS,00 • CO ►'11 Fax Number: Las L 3 GO L A Contractor Registration Number: 3e c\ * cri i C44 Company Name: Mailing Address: Q:\Applications\Fomis- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh Expiration Date: ARCHITECT OF RECORD — Company Name: Mailing Address: City Day Telephone: Fax Number: City State Zip Contact Person: E -Mail Address: ENGINEER OF RECORD — State Zip Contact Person: E -Mail Address: Fax Number: Day Telephone: Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind Contractor Registration Number: MECHANICAL PERMIT WE �RIVIATI©N 2 06. 431 -3670 MECHANICAL CONT CTOR INFORMATION Company Name: � � a - I P .a(1 1 Mailing Address: Contact Person: ( ` ‘r l 1n '\ E -Mail Address: Valuation of Mechanical work (contractor's bid price): $ .337 Scope of Work (please provide detailed information): \b\ \ a ( 04- l U r V\ (I Q\n I (",r 9eYY\ e. t U 1 u . Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ....f Replacement .... ❑ Fuel Type: Electric ❑ Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Applications Worms-Applications On Line13.2006 - Permit Application.doc Revised: 9 -2006 bh en i<N011 0)4 City � P Day Telephone: 23t!) al 6 t R ( o Fax Number: 42.5 452- - 0 1 -1 - j Expiration Date: 9,00_4 I 9 Page 4 of 6 PERMIT A ATION NOTES — Applicable to all permits in this ap rlleatlon Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Name: Mailing Address: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OyER OR AUTHOR! AGENT: Signature: O V ■ • el • D yT Date Application Expires: 01 / 1 .. , c Date Application Accepted: Q:\Applications\Fonns- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh City lephone: Date: ( 0I /200 / 2o X State Zip Staff Initials, Page 6 of 6 Receipt No.: R08 -00334 Payee: SEA -TEMP ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -030 Address: 757 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/06/2008 Applicant: DUKE'S CHOWDERHOUSE Issue Date: Initials: JEM Payment Date: 02/06/2008 01:04 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 6657 430.93 Account Code Current Pmts 000/322.100 350.74 000/345.830 80.19 Total: $430.93 Payment Amount: $430.93 8157 02/06 9710 TOTAL 430.93 doc: Receiot -06 Printed: 02 -06 -2008 Project, L) ( 64 s 0' h a �e y Type of Inspection: F 1 ium- Ad ss: Date Called: Special Instructions: Date Wanted: Requester: Phone N : 4ii - 3I L I — Lt 78? INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 'COMMENTS: r Wei co kg, 7 Approved per applicable codes. Corrections required prior to approval. Inspector: MD - 036 b Date: 7/ fl $60. REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Projec . L) 2/ 445 � h i t Type o c lon nspe —,: ,�� 7-7tiet Address: �,�/ Date Called: Special Instructions: Date Wanted: P.m. _ Q / S �_ Requester: Phone No: • INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. PERMIT NO. r (206)431 -3670 COMMENTS: 9/ peett o/c Inspector: Date: 7 El $60.O EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Corrections required prior to approval. • Project: Type of Inspection: Address: 75" /114, Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: s j' q v79/ INSPEGTrION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: • ❑ $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ti Project: ? / � fJ�� TYPeof In // / 1'0 43 ?a A -75 7 /M' / Date Called: Special Instructions: Date anted: j�" (i ��c✓� p.m. Requester: PIX1) .... 0193 3 INSPECTION NO. X Approved per applicable codes. COMMENTS: paid INSPECTION RECORD' Retain a copy with permit PERMIT NO. CI TY OF TUKWILA BUILDING DIVISION 12-. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 El Corrections required prior to approval. Inspector: 60. Date: /,/ Rai NSPECTION FEE REQUIRED. Prior to inspection, fee must be 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 3 COMMENTS: ' a .94 _,...., Type of Insp ion: /6�. -. / "--,00,46_ ' -.s .., mss r _of i- i:. 1 V _ / I/ -, :L[ y � l a t_ 1 (9 v/� 2 1 iip,,e_._ fr---e-I4 Date Wanted: a.m. I S 5,4...........0 0 etel" "30,44(7 7- Phone N ` J ." ,/ Project a 1 Type of Insp ion: Add es� 1 � ✓^�G Date-Called: Special Instructions: Date Wanted: a.m. Requester" "30,44(7 Phone N ` J r.• a INSPECTION NO. El Approved per'applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Corrections required prior to approval. Date . ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: Type of Inspection: Address: ate Called: Special Instructions: �LC'4ua°Soi- /0 44011% 4.4. a b sLO -.AA, J ad , J '� - J �� / � �'�l7 i���O Date Wanted: 3--/-901 p.m. Requester: ri b'.? Phone No: 2 N -e INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IF' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 K Corrections required prior to approval. COMMENTS: 041 amot." - PO „br CoJEc Jsiri t,. MA■ Ntrf4 '5 tASP(at, Addy oft, P aSso Approved per applicable codes. Inspector: Date: 05140 $58.00 REINSPECTION FEE R QUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Project: Sprinklers: r Fire Alarm: r Type of Inspection: Monitor: Cuero a v - Address: 2 Suite #: 5-7 c M 0-1...1_, Contact Person: i Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: r Fire Alarm: r Hood & Duct: r Monitor: Cuero a v - Pre -Fire: LJ Permits: P A Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. C INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. COMMENTS: Merl VtAk a 2 Ease•3 /- .c(I'J■01 — ajC ,rt. 4 j ` —OK Inspector: /21_,.1 S /y Date: 7/ 'l6 8 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Clllo Schedule a reinspection. T.F.D. Form F.P. 113 • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M08 - 030 DATE: 02 - - PROJECT NAME: DUKE'S CHOWER HOUSE SITE ADDRESS: 757 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui ap g' Division Public Works A14(' Fire Prevention LKJ Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUT NG: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Incomplete ❑ APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division ❑ Permit Coordinator No further Review Required n DUE DATE: 02 -1 2-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: n DUE DATE: 03-1 1-08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SEATE* *971 C4 Licensee Name SEA -TEMP Licensee Type CONSTRUCTION CONTRACTOR UBI 601770787 Ind. Ins. Account Id Business Type INDIVIDUAL Address 1 20838 SE 240TH Address 2 City MAPLE VALLEY County KING State WA Zip 98038 Phone 2068708367 Status ACTIVE Specialty 1 COMMERCIAL /INDUSTRIAL/REFRIG Specialty 2 UNUSED Effective Date 2/24/2003 Expiration Date 2/24/2009 Suspend Date Separation Date Parent Company Previous License SEATE * *027JT Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HARRINGTON, CHARLES E OWNER 02/24/2003 Look Up a Contractor, Electen or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond #3 Bond Company Name COLONIAL AM CAS & SURETY OF MD Bond Account Number LPM4073120 Effective Date 02/12/2007 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $6,000.00 Received Date 02/20/2007 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SEATE* *971 C4 03/03/2008 F6 25- 052 -(00 (8/97) DEPARTMENT OF LABOR AND INDUSTRIES REGISTERED AS PROVIDED BY LAW AS CONST CONT SPECIALTY . REGIST. # EXP. DATE CCAB- .: SEATE * *97TC4 02'/'2 4f2'.009 EFFECTIVE DATE .02./24/2003 SEA -TEMP 20838 SE 240TH MAPLE VALLEY WA 98038 Cl C2 C3 C4 C5 C6 H COVS7 SMITH & GREENE COMPANY KENT, WA DUKE'S - SOUTHCENTER TUKWILLA, WA COSTS MAY BE INCURRED, NOTE: MANUFACTURER IS NOT RESPONSIBLE FOR ELECTRICAL, PLUMBING, PERMITS OR CONCRETE WORK — �� 4� J x°�F,3 H �� Q l'co�c F g - rx nom•- E 7=- ,1-6 2 • ��a H ct, w REV# DATE , BY aK «1 DO NOT SCALE THIS DRAWING SCALE: 3/16"=1'-0" DATE DRAWN: 1/7/2008 DATE PRINTED: 1/7/2008 DRAWN BY: BRUCE GARRETT CHK'D BY: DRW #: 07- TD- 10898 -01 BOX: 1 OF 2 SHEET: 1 OF 1 Cl C2 C3 C4 C5 C6 sPECIPi CAT IONS Indoor cooler (no floor) NSF y Foam Gasket, Cam -lock layout #2 Pin Housing WALL ANELS Construction: 3 1/2° wood frame urethane Exterior Finish: 26 ga. stucco galv. Interior Finish: 26 ga. stucco galv. Connections: Cam -lock / Angle screed CEILING PANELS Construction: 3 1/2° wood frame urethane Exterior Finish: Metal Interior Finish: 26 ga. stucco galv. Ceiling Caps: Factory mounted Live Load: 10 psf DOORS 6° x 78' self - closing flush model G3 cooler door Frame: 3 1/2° wood frame urethane w/ 26 ga. stucco galv. (ext. & int.) Plug: 3 -side laps, 3 1/2' thick w/ 26 ga, stucco galv. (ext. & int.) w/ Magnetic gasket 2) Kason #1248 spring assisted hinges 1) Kason #27C cylinder locking handle 1) Kason #27C twist -off knob inside release 1) Kason #1095 spring action door closer w/ door stop 1) Single pole toggle switch w/ pilot light @ ext. 1) Analog 2' flush mount dial thermometer (12° capillary) ,6° high AFF .10 aluminum diamond tread (frame, ext. & int.) 36 high AFF .10 aluminum diamond tread (plug, ext. & int.) PARTS ea ea ea Vapor proof light (bulbs not included) 2 1/2 x 96° NSF approved aluminum molding 96° angle screed COMPONENT NSF LABEL N.S.F. LISTED (STD #7) N.S.F. GASKET @ ALL PANEL JOINTS COOLER: 11,073 BTU /Hr. @ 16 Hrs. THE MINIMUM BTU'S SHOWN ARE BASED ON NSF STANDARD #7, SECTION 5, PARAGRAPH 5.36.7, REQUIREMENTS (REF. TABLE 1). THESE NUMBERS ARE NOT INTENDED TO BE USED FOR SIZING OF REFRIGERATION UNITS FOR THIS WALK -IN. IMPERIAL MFG RECOMMENDS CONSULTING WITH A QUALIFIED ENGINEER OR CONTRACTOR. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical e lectrical Plumbing IGas Piping City of Tukwila BUILDING DIVISION Permit No Date: FILE COPY 0 OW Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or Ice. Receipt of approved Field Copy and • i3 . By c �� 9, g..0-0 0 City of Tukwila BUILDING DIVISION No 7C,Opr' Ji NOTE Revi'sicrs will rccuire; is new par submittal and may include additional plan review tees. -J � a co r` to I SPL 261/2 SPL 47 47 !rj 41 1/2 W1 69 9116 T W13 W12 26 1/2 47 ELEVATION W11 47 20' -0' [240] COOLER C 2 47 25 3/16 W4 W5 see component layout (1/1) p CEILING PANELS CD W10 W9 WB t A 47 47 25 3/16 r W5 W4 W3 W2 O W1 co D N WALL PANELS Finish Floor 61/2 EXT. i O S ME rv•Mma COMPONENT LAYOUT NTS 4 [A] 4 4 Wall panel I NT . Angle screed #8 x 3/4' FHSMS 2 1/2" NSF aluminum cove base Concrete floor (NIC) 21COVE BASE DETAIL Over concrete floor (NTS) .4 err' r A FEB 06 2806 �'filtrll7 (;ENTER 0 visfy - SUBMITTAL DRAWING - Customer Note: The Manufacturers responsibility is limited to manufacturing this product in accordance with these drawings. The customer or their representative In signing these drawings Is taking responsibility for overall size and fit around building walls, columns and ceiling restrictions, door locations, openings for equipment supplied by others, specifications and accessories listed. Production will not begin until these drawings are approved. ❑ APPROVED FOR FABRICATION WITH NO CHANGES 0 APPROVED FOR FABRICATION WITH CHANGES ❑ REVISE AND RESUBMIT Signature: SS. FINISHED NBRH- R2- 48- SSD -LT -PPW HIGH REMOTE BACKBAR REFRIGERATOR w/ S/S DOORS. LIGHT & PRE -PIPED & PRE -WIRED CONNECTION (110V, 5A MAX, 13006TU, R22) 49 1/2" 2 � MODULAR BAR DIE WALL (NMDS) 28' -3 1/8" (VERIFY) F 19 7/8" PLAN VIEW OF UNDERBAR EQUIPMENT FROM ITEMS 110 THRU ITEMS 129 28' -3 1/8" (VERIFY) 1' -3 1/2" -SP10-C -M CABINET RASED HANUSINK w/ A 10' EGFI SPLASH MITEREITA, iu rrm uarM KM imp NBRI l-R3- 72- LT-LT -PPW NBRH- R3- 72- SSD --LT -PPW HIGH REMOTE RACKBAR REFRIGERATOR W/ S/S HIGH REMOTE BACIRAR REFRIGERATOR W/ S/S DOORS, IJGtiTS & PRE -PIPED & PRE-HIRED DOORS, LIGHTS & PRE -PIPED & PRE -N1RED CONNECTION CONNECTION (110V, 5A MAX, 180OBT1J, R22) (11DV, 5A MAX, 1800BTI1, R22) 12' -O" (VERIFY) O JOCKEY STATION NBRH- R2- 46 -SSO-LT -PPW HIGH REMOTE BACKBAR REFRIGERATOR W/ S/S DOORS. LIGHT & PRE -PIPED & PRE -HIRED CONNECTION (110V, 5A MAX, 130081U, R22) (� DRAINBOARD SS. FINISHED O MIXER /DUMP STATION O WALL HAND SINK PLAIN VIEW - KITCHEN ITEM NO. 101 SSS SSRC - LT - PPW 1€11 REMOTE BAO®AR REFRIGERATOR W/ VS DOOR. 5/5 sADE ALL STA1LESS STEEL CONSTRUCTION. LIGHT, PRE -PIPED & PRE -r®REO CONNECTION (11DV, SA MAX, T OOBTU. R22) ELEVATION OF KITCHEN ELEVATION OF UNDERBAR - A - O BACK BAR REFRIGERATOR REVISIONS A 5/24/07 B 5/31/07 C 08/21/07 DRANK ER: Johnny Lee June 13, 2005 EIFJIER Arizona Rest. DUKES SOUTH CENTER.dwg N 27 (64) I, .I 74 66 65 66 S ®6 KAIRAK PIZZA PREP WiDRAWERS (REMOTE) RANDELL STEAM TABLE 55 CHEFS COUNTER LAYOUT REVISION 1 -25 -08 67 28' -8 1 KAIRAK PIZZA PREP 67 68 65 6 6 ' 0 " t_ k r. SIF T. KAIRAK PIZZA PREP HS SIDE SHIELD f WO3° dECEpjf ' OF TUl w o_A 06008 41 T (;EN Ef4 isxT WwEX Date 07.26.07 KC -1 EQUIPMENT PLAN KC 1.1 FLOOR PLAN KC -2 PLUMBING PLAN KC -Z1 BEVERAGE CHASE KC -3 ELECTRIC PLAN KC 4 ELEVATIONS & KEY KC -4.1 ELEVATIONS & KEY KC -5 HOOD DWG'S. KC -5.1 HOOD FAN DWG'S. KC -6 BAR PLAN M -1 DUCT PLAN 0 9' 0 rr CC C=7) C:7 Cgt • 0. ISM MI NM MI • MI MI NI MI IIII IM U - 4 I =■ 1111111Witimingst • 7 111111111111111111111111111111111111111111 11111 *0 -.=- 0 0000000 MINI: ; mi! il II Nig ilii (t 21 ... 1 =I t I tatliff 71 P. Mil I ° li 0 Oli - a 0 AI■11F NM= - Awarm ME 1■1■MIV ,ssm..amum■gawn■asisimil tmiron■srmossm:m ESISIMISIMIIIIMJminKLET.1 00 0 0 0 0 0 0 0 1 I I=1 ;V:44.itiritit4024[0:444.4■614A614:144402444666%!4 4565-1!4:!•4444.402:!4:1•444.4%!44605,44:144:124MititiV444.40.9%24.:V•Vi."44AAVS.14.4ite.4465.14.4.4.9r924•46.914.6N241•9 fit.iV.:!Z.:!:%!Z*'!.:W.9.Q•9.W.:S..'4KKAMSi9!44ptit:AiWi...tWf4M.:W-i[':o!:.%V.4iAe4:t.:!!Zte.44iI!46!44Mk.*M4W.• itiVit4i1W4MI.40.44e4:24:92462.2444:1444 III STIHR 111:1314 $ • 1104j • 00** „.„ MEM! 48 1 Ar3 my.= rmr,g XI LJ nfl LLJ fin LJLJ S 0 z cn z z 0 0 z 0 0 0 0 a 0 0 z z 0 0 a 0 0 0 0 0 0 0 Ph - o 0 m y / / / II 0 0 0 • // , / //` 0 / Ph 4 U) t 4114 7 ; / / / ' Nfr , 40AUUV2Y-W , Wr 9 - ins E: ,;,.• . 8 g 8 85 8 8 1 88. es is 8 C. 8r : p'11 z g Es s ig 981M999919ta t -- Ergir - 47611 -7 b1 tfli iti a tr. ; ral *-; 8Tr, 7 rr., aTK . . . . . ; I i . . • - 4 i 4 . . ---1 ---J---1 - -- -- _1 :-- i 7--- , --i : M •-■ 10:-.;•-•.t.:.2--•;--•!-..•-•:-.'na••):m .+. -..-1...-- ..... . •-• • --.• •-•• • 14 ..... • --...'n, 14.-- I.1 : 1 1 hp : 41 . -.I- -7 . ..!.........;._. se le eicjrc.rc!-Iii ' ri:if ,, 1 lg. 011 N- ihilm. ig III 11111 1 il' - 1 ' ri ii Fill .1 ! 5 M• 0 0 C 0 ! 1 7 _7 ' permit submittal drawings - not or construction " 4 * > 0 ci D1 : • : . . . r '41!+!. • AHT S T HF 1 1 0 4 1 Ci U-NI" 7 r - M:k tilitP1111153. 11011.1 O 41 2! !A 41 4 5! DUKES AT SOUTHCENTER -- I 1441 L -9 ; 1„ v oc;:, 3 N -„ TA.w 2, 1 0 ;:e.gr , 'PKI-M X :0 6 NWWIN- fq " ; . q b1 - klr 111'6" ' 1111t4 "--' . : rJ 1 '- . - Smith & Greene Company FOOD SERVICE EQUIPMENT & DESIGN 19015 - 66TH AVE SOUTH KENT, WA 98032 (425) 656-8000 * FX (425) 656-8075 Li ; -13 z c rn Co 73 ,2 m ic I 1 --- f -- 1 - E m 111.1:u: -I 1; 18" a GA. S/5 PULL= 5 SIDED PULLBOX DETAIL BEVERAGE Sl'5tEM CONDUIT SHALL BE 6' INSIDE DIAMETER MINIMUM BEND WITH 24" MNMUM RADIUS EASY SWEEP BENDS AT ALL TURNS AND FLOOR PENETRATIONS. CONDUIT SHALL BE RUN BELOW FLOOR SLAB WHEREVER POSSIBLE AND SHALL BE ROUTED TO PROVIDE TIHE SHORTEST RUNS POSSBLE FOR ABOVE SLAB INSTALL- ATIONS CR WHERE CONDUIT PASSES THROUGH RETURN PLENUMS. PROVIDE 6' E.M.T. CONDUIT (PVC WILL NOT BE PERMT ED). INSTALL PULLBOX EVERY 75 LINEAR FEET OR EVERY 3 BENDS WHICH EVER OCCURS FIRST, ACCESS TO PIALBOXES MUST BE MAINTAINED UN11L BEVERAGE LINES HAVE BEEN PULLED. CONDUIT MUST BE WATER TIGHT. DEBURR ALL SHARP WOES AND SAW CUTS ON INSIDE DIAMETER OF CONDUIT. PROVIDE 18 MINIMUM CENTERS ON CONTINUING STUB -UPS STUB -UPS SHALL BE 6" AFL CAP ENDS OF CONDUIT DURING CONSTRUCTION INSTALL ELECTRIUANS PULL UNE IN CONDUIT UPON COMPLETION OF INSTALLATION Al PENETRATIONS THROUGH FLOOR SHOULD BE SEALED AND FOAMED. TYPICAL BEVERAGE CONDUIT INSTALLATION NO SCALE SODA DISPENSERS �z J -r.- .gee:.: _.,..� ...max-- .......:....- ,- _..:..... ,_... �.,,.... .. ra-,. �• c^';g ✓��-:...:_r,�- s�c..a.'T' 'fir xw ti Y' 101 UNDERFLOOR SODA LINE CONDUIT UNDERFLOOR CONDUIT CONSTRUCTION (BY G.C.) 1. CONDUIT RUN UNDER FLOOR MUST HAVE SMOOTH INTERIOR. ANY CONDUIT MUST HAVE ONLY ONE (1) 24" RADIUS SWEEP BEND (45 OR 90 DEGREE) AT EACH END WITH NO ADDITIONAL BENDS IN THAT CONDUIT, PLUMBING STYLE P.V.C. FACTORY - L" ARE NOT ACCEPTABLE. 2. CONDUIT MUST BE CONSTRUCTED WITH TIGHT. INTERNALLY SMOOTH JOINTS AND MUST BE LEAK TIGHT. PRESSURE TEST AS REQUIRED PRIOR TO BACK - FILLING. 3. CONDUIT TO BE CAPPED AND SEALED AT BOTH ENDS DURING FURTHER CONSTRUCTION. INSTALLER TO TRIM EXPOSED ENDS TO 4" ABOVE FINISHED FLOOR DURING PRODUCT UNE INSTALLATION. AFTER PRODUCT UNES ARE INSTALLED, THE OPEN ENDS OF THE CONDUIT ARE TO BE FILLED AND SEALED (WATERTIGHT) APPROXIMATELY 2" TO 4" AT EACH END. SPECIFY AS: PROVIDE CONDUIT AS DESCRIBED IN ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE TO MEET U.L. STANDARD 651, NEMA SPECIFICATION TC -2. ROBINTECH P.V,C, DUCT AND SWEEP ELBOWS OR EQUAL DIAMETER TO BE AS INDICATED WITH MINIMUM BENDING RADIUS OF 24 ". PLUMBING STYLE P.V.C. FACTORY "L" ARE NOT ACCEPTABLE -" 24 RUMS S MOE CONDUIT METHOD 'A" ■ I 2 I t�CONCRETE NA AS Wf,11 SLEEVE STAB OPDINC CONE SEALT BY K.E ALL µ AROUND FINISHED FLcoR BY G.C. CO CON GG TE :LAB WATER PROOFING FI FIBERRMA.% PACKING JOINTS SEALED AND WATER TIGHT CONCRETE SLAB BY G.C. BEVERAGE PACX ICH 1 N AF µ �BER WHERE C SIGIFICANT 1FERMAFBER PACKING FULL DEPTH ALL AROUFA BEVERAGE SLEEVE NO SCALE COMITY SODA LINES & INSULATION SLEEVE BY KEG. METHOD "B" STAINLESS STEEL SLEEVE BY KEG ALL WELDED WATER TIGHT CONSTRUCTION WAD FUH X NNLESS STEEL FLANGE SEAL BY P.C. 24" MPH. RADIUS SODS LOCAL DIES WAY IPEOLK NIRKNiu. OR ALTERNATE ICBMS P6(IRATI H 1WW 11HIEE SINSI ARM, REFER 10 CRAMS S NO CRATING NOES RR CONDUIT SIMS N9 TRACT: [MARX 4 1, 7 r' TOFRA. j KEUS 1. PLUMBING PLAN SHOWS ROUGH -IN AND CONNECTION LOCATIONS WITH DIMENSIONS AND CAPACITIES. PLUMBING CONTRACTOR RESPONISBLE FOR CODE REQUIRMENT MODIFICATIONS 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY VALVES, TRAPS, TAIL PIECES, LINE STRAINERS, PRESSURE REDUCING VALVES AND VACUUM BREAKERS AND CONNECT ALL WATER, AND WASTE LINES TO FOOD SERVICE AND BEVERAGE EQUIPMENT. 3. PWMBING CONTRACTOR SHALL INSTALL AND CONNECT ALL FAUCETS FURNISHED WITH FOOD SERVICE AND BEVERAGE EQUIPMENT. PLUMBING CONRACTOR SHALL FURNISH AND INSTALL ALL INDIRECT WASTE UNES FROM FOOD SERVICE AND BEVERAGE EQUIPMENT TO FLOOR DRAINS AND SINKS AND INSULATE WASTE UNES FROM ICE BINS, EVAPORATORS AND BAIN MARIES. 5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ADA BATHROOM COMPLIANCE AND WITH LOCAL CODE REQUIRMENTS, IF NEEDED �� --......:::..\-::-.. �, \\ 1i c. l _ , "' \I; .. ti, ♦♦ \-...."-,-... 1 `-'`. J `\ x.11 I .,`. t ( - ^mil 10,,,_''. _______ ._ -i}LJ 1.. r. �. `,♦ , u `'` PLUMBING NOTES I0;2j 3 PLUMBING SYMBOLS HW -HOT WATER, OR CW -COLD WATER . i �J WALK IN HET 6 )1 0 :1 i WASTE, DIRECT - CONNECTED UNLESS NOTED "OPEN HUB" FLOOR SINK, W/ 1/2 GRATE 9 INDIRECT WASTE FLOOR DRAIN PREP BEVERAGE LINE Pt.A 1/4 ".1'"Q"' r 41 s_- - tea • , .4-7tARY.MP4IE ;i,•.a I y , p 16 j j i .P v� 9 d. .I . r F �� r E- !3p - j'I III 1 _ '•'.s� "Cis.' : w +' �vs,?t...�w�c�....� • ".`•f ..� ."+4Y MO8o3o RECEIVED CITY r TUKWOA FEB 0 6 2008 ''Ef' I'>ar TEP CC Lu z U 0 Q Sheet Sim ARCH D NH?. # KC -1 EQUIPMENT PLAN KC 1.1 FLOOR PLAN KC -2 PWMBING PLAN KC -2.1 BEVERAGE CHASE KC-3 ELECTRIC PLAN KC 4 ELEVATIONS & KEY KC-4.1 ELEVATIONS & KEY KC -5 HOOD DWG'S. KC -5.1 HOOD FAN DWG'S. KC -6 BAR PLAN SUBMITTAL SET 3 COMP SINK REV. ELEVATIONS ROUGH'S ReNsbn/Issue 8/06/07 B/06/07 7/26/07 7/12/07 Date 07 -26 -07 2 3 COMP SINK REV. 8/06/07 1 ELEVATIONS 7/26/07 1 ROUGH'S 7/12/07 r DUKES GAS LOAD CALCULATION SCHEDULE Thal NO "G1Y EauIPMENT CATEGORY 20 I 1 OVE71, CONVECT/DR OA6 1 RANGE HEAVY dR(3i14 Y, 1 MAX 4 S LP ARE U 18 ,FRYER. DEEP FAT, SAS PLUMBING NOTES 1 1 ORIDOLLGAS 1 IUD TEROAS 11 ,CHAR BROd ; _. _... 2 RANEE, HEAVY DUTY, GA4 78 212 30 SUB TOTAL FOR 1011111E31 EI311641ENY 1,932 1 F HEATB83 LIMY ____.________ ........ ........_i ,.... _._.._..._ _...,_. � .. WATER HEATERS t . TOTAL FOR BURDENS ._ ............. _____!...._....._._...._... _..__._��.........,.. -___. r�� .:.eF:� =!'-s �?';•�- re-�.� ':_�.�.:.:_. .. 7444.. i..:, ._..5.. ., 444,3. _:_ e 9 10 20 3z 34 35 37 40 41 43 45 46 41 54 56 s7 5T! 07 75 n I = x x x i El i ! z a i l f i _i ' I i �.^� « C7r�1 _1 {y , 1.. I tit S {yy 1, yi § cci� Na a1YErQUIPMENT CATEGORY 0 o Y , - - - - - - - - -_ yy,. -_.. u1 b .._._. d"� C a l_ _-_- 1, KEI pLusann $ 1 EVAPORATOR CO4 • VC YN1�4 OW }j O�L `.7.75 5 � 12 L 4 RD O ._ 1AIR-GAP WHEAT TAPE , EV MORATOROO G. I +B8 AIR131LP TO F$ ..... EN - -- + - -- L . - - -- _ I 2 �A Rid1AP 7° FS I OVEN CONVECIION.GAS 1 . { I-- - �MR 12844 I 1 MOP SIC i 3 0 F_ ... I U78- RYFA11(7ET 12 38 1T2 38 .__ 1 ICE RAKER WO BPI 10975 1 r -1 05 AR-GAP TO FS r { 1 BD, ICE 4444 I _ - -y L .� - � J..° .. 1_. .. .._ AR-0AP TO FS 1 WAJEWASF N RACK CONVEYOR j j ..__..y._ -7' 444 1'---._ .}._.._-- Z ,. 11 8 J W.... wASTE ri mCOOE rnsE , r z � 4 ,z _ I r tvERlFrwrvTemoR 1 P t -- RER833E FAUCET WALL M0111i I.. 1E. 1 a6 18 --- 344 t R wasrE PER COED IL 1 1 i 1 115 FAUCEr. WALL Ob -, 1B - - T _ _ + _ 4 _._ � ��^ ,4 3 4- .... -. + 1 - - - -- - --- - z 718[FAmwALLMO-11Tr RANGE. HEAVY DUTY, 130.4 1 3.75 16 FRYER, OffPFAT, GAS { + OTS 110 1.i5 1 GRtonte, t1A4 4444 f T5 1 180 30 t ._. 4434 1 CREESENE 1ER,GAs I t { 3444 [ 443 4 - 1-.. { 68 T 74 V ERIFY 4433 1 CHAR BRO0.E]i Ir I .T8 I 1e0 f 30 1 ST 2 ' RANEE.. HEAVYDLCY,CK4 _...---. �. ---- l t __1 �� + �2 T 30 EAM TABLE % LFA WIUCET S 24 I 1 -- 1 118 WATER L 87 , 814 CROP- DAMN t - - -1 I - ,s z, � 4_ t 1 FAUCET DECK MOUNT j r as .. 27 . 1 0s Y 21 1 i T 83 3 SIC,OfmReiW/3OESPIASH .5 21 5 21 1S 24 ..... _ 4443 4443_ 4444_.. } . �. ._.._ .._ a ... _..,. _ 4474 , 4344.._ 7444. t.__.. 3343 94 2 O(AP D, � .. _ ._. �. i 1 L 13 f , - IAOi - GAP TO FS ^.. T... T.. 7444.. 96 .. 1 (WATER STATION 1. as L 35 T ' Ta a1 i 35 1 T._... A9i-0AP TO FS _...._..._ t 7Y 07 1 DIPPERINELLASSanY 1 10575 T 075 128 An-GAP TO FS 110 1 SAD< BAR c I- L .. _ 3433 107 1 EVAPORATOR COL -OEG $ r _J r .__.. �. .�1 R 70 FS 111 1 MACK . WOEIITTAPE oOLER . _ ..- .__._.._.._... 3343 AC BAR COCLei ..- r.. I 1. i 0.5 r 4 443 AIR-0APTO FS 112 2 r 1 3444 1 25 � _ - - 112 SEER TAP TOWER .. � 1 3p i AIR-0AP TO FB 2 1 SACK D AR COOLER � . F L I a5 L am 1 F ' AUi{3APT0 FS 11$ r 113 UI4EABAR FILLERS 0 A5 OPRES + 4 , 28 r - - ._.. - " -' 1..._. .. . .__. ._.. r _.._ 44,44- ? UN DEEF] ii C OMB.( EBIN 77- - t - -- - - _ -_ . _� _ 1 -- -._ ABi-0APSO Fs 3344_. _ 118 1 UrIDF17BARCO60L ICE BIN _._ ! 1 15 j +_ . � ..... ... .......... BLENDER 118 1 �UNOER&ARCOMB.ICE � _ F __.. 3444. -. ♦ .. 1 ..._._ ..1_._ 1 Os 15 IA83-0AP TO FB 122 ..F 1 IUND ARHANCS1NK STATION � ^ � _ .. .. } .. ._ '' . 14 1'S 21 � I ,... -.. -. AR-GAP TO FS tt _........J -._ _. 124 2 GLA38NOL4F♦t3i x375 7s a975 75 I 15 17s t 1 Vf370 7 FD _., 2 FLOOR DRAW 7443 __ ., - _ {. _....�_ _. 3 T 3 r __ _. 1 _._ �.._ j ..__ 4333 I .�.- ._. }_...._. .___.� FS 1tl FLOOR SOIX r 434 7 3 1 1 + 1-- L__ ... L � V2 1 IS . _.. 3434_ _ VI 21 MA1 u..c I s L 42 •- r 1 � _ r i ISO 1- .8 T2 . . I -- 344,4. I 1 . --. I . � L a BFRV - 4443 -- wH 2 ;WATER HEATER ELECT _ 14 r+9e L 1 I ._._ L � } 4433 .` VERFY eN P.C. 1 3RK2COA 1 FAUCET WALL MOUNT t 05 18 i 123 18 128 2 IDRYGIASS STATEN - n..- vF:^�cY!M:.XY.S..;.':- s,•'`+:�C :=�.•; -=.- -Po=- Pj�T -;f:7 HW -HOT WATER, OR CW -COLD WATER PLUMBING SYMBOLS WASTE, DIRECT - CONNECTED UNLESS NOTED "OPEN HUB" FLOOR SINK, W/ 1/2 GRATE INDIRECT WASTE FLOOR DRAIN 1. PLUMBING PLAN SHOWS ROUGH -IN AND CONNECTION LOCATIONS WITH DIMENSIONS AND CAPACITIES. PLUMBING CONTRACTOR RESPONISBLE FOR CODE REQUIRMENT MODII1CA11ONS 2. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY VALVES, TRAPS, TAIL PIECES, LINE STRAINERS, PRESSURE REDUCING VALVES AND VACUUM BREAKERS AND CONNECT ALL WATER, AND WASTE UNES TO FOOD SERVICE AND BEVERAGE EQUIPMENT. 3. PLUMBING CONTRACTOR SHALL INSTALL AND CONNECT ALL FAUCETS FURNISHED WITH FOOD SERVICE AND BEVERAGE EQUIPMENT. 4. PLUMBING CONRACTOR SHALL FURNISH AND INSTALL ALL INDIRECT WASTE LINES FROM FOOD SERVICE AND BEVERAGE EQUIPMENT TO FLOOR DRAINS AND SINKS AND INSULATE WASTE LINES FROM ICE BINS, EVAPORATORS AND BAN MARIES. 5. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ADA BATHROOM COMPLIANCE AND WITH LOCAL CODE REQUIRMENTS, IF NEEDED 2 1 .1 a PLUA®ING T _ � q R9 WR1[8 075 ..1_ 0.7 5 80 42 R .._ OAS CO. ___.._.___._.____..__ 751 EANNECTION _.1 . 77 99 6257 . 1 ` --- ' - --- -- I _ 0.75 110 16.8, .75 180 ..21 78 ± 48 T 74 -._. -. .75 180 ' 3oTREAR OAS CONNECTION PLUMBING SCHEDULE t318 .615 - ~ '1#67433 NOTES: 1. P.C. RESPONSIBLE FOR BPR VALVES AS NELL BY CODE. 2 SUPPLY FROM WATER FILTER WALK IN FRF.7.E.R (018 1 x 'I I t;6:4 ,05411 *»".i - ,-,,E '.T.' Ay-- ,tz !. E..1 -..s6 1 i) TFs,FS: . 1t4 ritlfittr I I ,• N orncE 0451 nil IV R. WM RCM II • 14'-8' Ohl N \ \ :TMPLOYEE 4S42K [,1�7 Eo , PLUMBING PLAN 1/4" = 1 ROOF MVD ITEMS 030 &.3 6;►tYp; TI,v. v1 .4 FEB 0 6 2008 RMiT �; J stir. 3 KC -1 EQUIPMENT PLAN KC 1.1 FLOOR PLAN KC -2 PLUMBING PLAN KC -2.1 BEVERAGE CHASE KC -3 ELECTRIC PLAN KC 4 ELEVATIONS & KEY KC-4.1 ELEVATIONS & KEY KC -5 HOOD DWG'S. KC-5.1 HOOD FAN DWG'S. KC -6 BAR PLAN SUBMITTAL SET 8/06/0 Dote 07 -26 -07 Sheet # KC-2 �c�e: 1/411 -11011 2 3 COMP SINK REV. 8/06/07 1 ELEVATIONS 7/26/07 1 ROUGH'S 7/12/07 ELECTRICAL SCHEDULE ITEM d I "r (; NO QTY EQUIPMENT CATEGORY m > ' 41 C 4 4+ 200 LI I 20.0 1 , 1 WALK W FREIE R 1 120 11 60 X ' 108 1LIGHT6 & CONTROLS 2 + 1 i EVAPORATOR COIL .. _ - - - -.. +-- .._,.... 120 -- l i 4. 60 t -- X `--- 1,. '8D TVERIPY. HEAT TAPE DRAW I 120 I 1 60 _LX ! 108 !LIGHTS & CONTROLS 5 1 WALK IN COOLER 1 1.. ] C . rv me x ER a - 56 7.0 . r 0.5 _. I . T 120 T1 y 60_ J X I x j 5-1 44 ;VERB f .. 11 1 C � t - 13 1 1 0,75 20B 1 1 60 XT - f 1 12 16 1 I CLA55 II EXAUBT HOOD 1.0 1 120 1 60 ; X 1 108 ILIGHTS & CONTROLS .. _ i + r t t t -- 1 1 - i 4 7 sLIC 2 IER N. GAS � A � ------- i I 2x �� (�� ± - - � - i - - - x 5-1 5-15P - T 44 �- _ . 2 0 -- -. 1 I t OVEN,CONVECiIO CONDENSER/ -•- - -- - -- .____.. 1 oaRN_..._ _._.___._ N_ _N - � .._._.- __._._. 1 - L-.__ 1_ ._._._i_____... 28 1 ICE MAKERCOND REMOTE 19.6 i 3.0 i 208 7 6o X' I 12 VERIF YWNENDOR ._ 27 - __._.._. _ �..L_.._.__ . 0 ,.._.�..______.____ 27 1 FREEZE REACH -IN 11a 0.5 1z0 11 80x� 5-15P 12 . ....... . . . .. 34 1 ICE MAKER W/O BIN 60 VERIFYw /VENDOR 40 1 , WAREWASHER, RACK CONVEYOR 0A 120 1 160 , X i •__ 108 • LIGHTS & CO 19.5 ..Ij.. 4 30 ' 208 1 ! -- 206 X1 1 . .1..- 1.. - - - - - . 2� .... 1 * 60 X 47 r 1 RANGE, HEAVY DUTY, GAS SA _• 0.2 1 120 1 1 60 I 1 X T 5-15P r 12 ` 55 1 WARMER,FOODOVERHEAD -. ± 5.7 L 0.7 ' 1 120 11 I 80 I X 5- --- --- 48 1 CLASS 1 EXHAUST HOOD 0.4 120 1 160 , X L 108 !LIGHTS & CONTROLS _... _ .. _ �_NDQJSER, REMOTE - - - - - -- .. �, ----- -•-- 15P ' 24 1 • 62 1 PREP TABLE CONDENSER, ER 19B _x..•3.0 + ._. 208 1 60 I X T- 5-15P 24 ' -- - - --'- 1 7 - --- - -- -- -- NITER DRAWERS - - - _.._ -_ 1 7 -- -.._..... -- 120 i "I X t .. ... -- -- - + 12 - 58 1 GR GAS 1.G 120 1 _ I 80 ir VE 17-8 20 120 1 1 6 0 I I .. - 12 1 REFRIGERATOR, 63 1 (PREP COLJ -.. 1- -- - ---- - � 520P - �' - - ---. 84 y 1 OVEN, MICROWAVE - .., r .r ._ I . 1._ r - - EV LVERIFY 65 .." ..._ T PUMA PREP 3.0 _. _i 120 11 60 1 X r 12 • 67 1 ' STEAM TABLE W/F6_L F A U C E T - - - - - r 125 2 . 6 80 4 u• X 8-20P 12 87 3 WARMER, FOOD,ELE�TRIC _..__.- _ 13.8 1.7 .._... 120 1 60 IX ...•. 5 -75P 44i 3 WARMER, FOOD OVERHEAS --- 16.8 3.5 208 1 BO TX 1 i I jWARMER, FOOD OVERHEAD 2 -WARMER, DRAWER TYPE 91 92 95 100 101 107 110 111 113 120 124 CN2 CNB CTV DAT TV V1 V 1B V2 V3 V4 V5 13..5 28 208 I 1 60 X 7.5 0.9 1 - 120 , 1 ! 60 - X 5-15P 1 1 1 'PREP TABLE CONDENSER, REMOTE 19.5 f 3.0 208 I 1 60 X 1 i 12 ■ .. ._ 1 ;BACK BAR COOLER 5 } 1 20 1 60 I X T 1 24 } 1 1 BACK BAR COOLER = r EVAPORATORCO ... I _ _ - � ! 120 1 BO X� I +8D 1 VEPJFY, HEAT TAPE DRAIN I ( + , r 2 1 �G 21 1 BACK BAR COOLER 5 120 1 1 BO 1 X� 4 - - L - I 2 i EREU\R BLENDER STATEN 15A } -- - - 1 1 1 60 [ x 1 I .. 2 _� 4 J - 24 I- 14 2 ' CONVENIENCE OUTLET 15.0 120 1 60 X 5-15 G LASSINASHER T 150 4A r L 120208 , 1 60 * 12 VERIFY W/ VENDOR I 1 i P 48 V t 15A - __ _ _. 120 F1 60 I 1 XT 5-i P 1 44 HORIZONTAL 2 CABLE T _........... 15P 44 - DEDC- CATED CIRCUI --_ IBARWALL 15A 120 1 60 X 2 !PLASMA FLAT PANEL 15 .0 120 1 1 60 t 1 X 5-15P ` 44 tDRD ED ECAT CIRCUIT 7 DATA & PHONE ANEL T 10.0 120 1160 1 ; X 5-IEP 1 2 1 COFFEE MACHINE ... 30.0 120208 } 1 1 60 1 48 144 'VERIFY 4 BAR GUN 3.5 + �_ 120 1 60 • ! X 5-15P 1 24 I i BIB RACK 10.0 1 120 -11 . 4 X 6-15P 1 12 1 COUNTERTOP REDBULL COOLER 12.0 120 1 60 pc 6-15P 1 44 VERIFYW /VENDOR 1 JAGER 12.0 [ 120 f 1 60 1 X 6-154 1 44 VERIFYW /VENDOR 1 ' r ' OIL FILTER SYSTEM 15.0 1 I , 120 1 60 I X 5-ISP 148 VERIFY Im Lin Ti FIXTURE MOUNTED JUNCTION BOX FIXTURE MOUNTED RECEPTACLE INCANDESCENT UGHT FIXTURE FLUORESCENT LIGHT RXNRE HELD WIRING RUNS DUPLEX RECEPT., 20-AMP, 120-VOLT, GROUND TYPE, VERTICALLY MOUNTED OR IF47'AFF. INDICATED, MOUNT OUTLE7HOR/ZONAL SIMPLEX RECUT, 20 -AMP, 120 -VOLT, GROUND TYPE. VERTICALLY MOUNTED SPECLAL PURPOSE OUTLET, VOLTAGE AS INDICATED, GROUND TYPE, VERI1CALLY MOUNTED HARD WIRE CONNECTION POINT JUNCTION BOX, VERTICALLY MOUNTED SWITCH ELECTRICAL SYMBOLS ;5T ELECTRICAL NOTES 1. ELECTRICAL PLAN SHOWS ROUGH-IN AND CONNECTION LOCATIONS AND DIMENSIONS WITH CAPACITIES. ELECTRICIAN IS RESPONISBI E FOR VARIATIONS TO MEET CODE REQUIREMENTS. 2 ELECTRICAL SYSTEM S DESIGNED FOR I2JI208 VOLTS. I AND 3 PHASE, 60 HELM, 4 WIRE SYSTEM. 3. ELECTRICAL CONTRACTOR SHALL RIRNISH AND IN'iTALt ALL JUNCTION BOXES. RECEPTACLES, COVER PLATES, PULL BOXES. CONDUIT AND WIRING EXCEPT WHERE NOTED. 4. ALL CONDUIT RUNS INDICATED FOR REFRIGERATION, DRINK AND LIQUOR SYSTEM LINES SHALL BE FURNMIED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, CONDUIT SHALL HAVE 24' (600MM] MINIMUM RADIUS BENDS. 5. ELECTRICAL DIVISION SHALL FURNISH AND INSTALL EMPTY CONDUIT WITH JUNCTION BOXES FOR INSTALLATION OF OWNER SUPPLIED ELECTRONIC CASH CONTROL SYSTEM. ELECTRICAL IN ACCORDANCE WITH OWNERS REQUIREMENTS AND MANUFACTURE1tS t zi L+-' EL EC W �' REMARKS NOTE 'A' 120V, I PHASE. SERVICE I0A AMPS. SI 18 AS NOTED, CONNECT AT POS/PRE -CHECK STATIONS. (DEDICATED CIRCUIT. LSOLATED GROUND, ADD PHONE UNE, PROVIDE EMPTY J-BOX WITH CONDUIT FOR INTERCONNECTING POE SYSTEM, CREDIT CARD, DR. PHONE & FAX UNE) (VEPJFY ALL REQUIRMENTS WITH POS SYSTEM SUPPUER.) ALL WALL MOUNT ELECTRICAL RECEPIICLES AND J -BOXES ARE TO BE RUSH MOUNTED IN WALLS WITH NO EXPOSED CONDUIT SHOWING ON SURFACE OF WALLS. ARCHITECT TO PROVIDE MINIMUM WALL FURRING IF REQUIRED. v- x. zx.•�: r . WALK IN 'REF.. �viL4� 1 y a5iy'F". t- . it trw?K .5£` 3 '�k 4' ; A�. �. /a „ #, ��.tt � 'wvyt5te�€�,C � � ,a -' ��£� a �y_y a�3�at��� G := � a"1� ' .. � ,. Y Y•�i k� E .PI_EiY =r. Rr( !IA rPi.4,.1 V-3' 7 -3' T -11' 2 -10' ID III III IU` st. l n 11►, I; d llr� I .r©; 3'•6• 3' 2 -11" 1'4 " 1'-3' 2 -11' 1-5': - ; ,.) 3 ' -0 " 2 -11 " -J N PR V V Is`(NfNNG; DINING D121 ROOF MT'D ITEMS co ELECTRICAL KAN 1 /4 "a1 ct • tb 8o R c tv crr CJF r(ihl�} FEB 2003 PEY' s'AJ ] 0 t U C 0 0 0 C N 0) C p 0 a C 0 U, 4�^ Q '" as -L7 --T'c5 - .sue t ,,, M1. No. SET.# KC -1 EQUIPMENT PLAN KC 1.1 FLOOR PLAN KC -2 PLUMBING PLAN KC -2.1 BEVERAGE CHASE KC -3 ELECTRIC PLAN KC 4 ELEVATIONS & KEY KC-4.1 ELEVATIONS & KEY KC -3 HOOD DWG'S. KC.5.1 HOOD FAN DWG'S. KC -6 BAR PLAN r : SUBMITTAL SET Revision/Issue Date 07.26 - 07 8/06/0 Date 2 3 3 COMP SINK REV. 8 8/06/07 1 E ELEVATIONS 7 7/26/07 1 R ROUGH'S 7 7/12/07 1111 I1111 IF 1'. 1111111111 . 8' -8" A.F.F. (TOP OF HOOD) /-, /7/7/ -7 % , ;7 - ` % it / % 6'8" BOTT. OF HOOD f 1'-4" Fryer Dump 3' -2" 11 -['1,1 ; _... '77 DBL. STACK OVEN TRAY RACKS SLICER 8' -8" A.F.F. (TOP OF WALK -IN 6-4" Fryer Battery 010' -6" A.F.F. 9 -0" A.F.F. (CEILING HEIGHT) 0' -0" (F.F4 WALKWAY if fryer Dump i L...; .Li.. r .. _ ._ Refrigerated Base 3' -6" 6' -1" DDT RETURN SCRAP SINK PROCESSOR 2' -10" 2'-10" -- fi t' Range Range Oven Over! 010' -6" A.F.F. � 9' -0" A.F.F. (CEILING HEIGHT) CO CV x 2 c3 O m 9 t 1. [11. 1I1.: i ;.- 3' -8" 7-1 " 2 ' -6 11 WAREWASHER ' CDT RETUR .7 t� I l • [ • 4444- 8' -8" A.F.F. (TOP OF HOOD) 6'-8" A.F.F. (BOTTOM OF HOC 2T 22 (12) 12 28 iD 29 // 13 ' �] L (BLOCKING) L 3 1 -5 " 1 6-0" 3 COMP r' ELVING 2X72 SHELVING 18X72 6 WORK TABLE I HS rt T C i 7 SHELVING ABOVE 18' -0" (BLOCKING) SHELVING 12X72 SHELVING 18X72 6 1 -0 " WORK TABLE (SI) 8 111 1/1 i • COFFEE , - TM i fi ,... _IL _II- � -h- 4- 4 -._.__ _ -0 -0- BEVERA 12'-4" I .1 14' -0" SERVICE COUNTER V - T 1 d ;_� ELEVATION KEY PLAN 3116" 41'41' SHELVING 12X72 SHELVING 1 8X72 93 (94) (88) IDASTO WORK TABLE 6 , -0 " _ 1' -6" , 1' -3" HE ICE BIN U a 2' -6" 21.21 MIXER HS PLASMA N RECEIVED crr' OF TtiVifL 9, FEB 0 6 2008 PE MIT UEN EP t1O8O3O c Sneer Size ARCH D S. KC -1 KC 1.1 KC -2 KC -21 KC -3 KC 4 KC -4.1 KC -5 KC -5.1 KC -6 HiLla EQUIPMENT PLAN FLOOR PLAN PLUMBING PLAN BEVERAGE CHASE ELECTRIC PLAN ELEVATIONS & KEY ELEVATIONS & KEY HOOD DWG'S. HOOD FAN DWG'S. BAR PLAN 3 SUBMITTAL SET 1 8/06/0 Revision/issue Date 07 - 26 - 07 Zi..; ; „, . ........... \ V s...; / .7” ..... . , . . . . . . . 1 s 1 ... —._ •,. -. e.. ...... mrd.,,. . ■ ...... IL, .... . Mal =CNN 1 ..... aVg 9'-0" A.F.F. (CEILING HEIGHT) FULL LENGTH COUNTER TOP '45INERVitffingliE ARCH D 10'-6" A.F.F. 4 A.F.F. (CEILING HEIGHT) 0 (F.F.) 64 PANASDNIC MICROWAVE 3 1'-0" ' ; 2-2" -/ ICE BIN BLENDER DRADJBOARD GLAS.STOR. WALKWAY (OTHER SIDE) EQ - AvY • EQ 14'-8" OPEN SHELVING DRAWER W UNDER CNTR COOLER 14'-8" 24' OPEN BASE WORK TABLE FOOD WARMER 1'-9" 2'-5" BEVERAGE LINES SEE KC-6 FOR BAR PLANS AND ELEVATIONS 2'-6" ,,,,,. 3'-6" 11'-0" 4'-0" / / / / HAND SINK GLAS.STOR. DRAINBOARD BLENDER ICE BIN GLASSWASHER GLASSWASHER 29'-3" HATCO WARMER ... HATCO WARMER SSP 3 TIER PASS SHELF 24" OPEN BASE WORK TABLE 28 - HATCO WARMER 1 ,1 m=======W;MMZ=Z=Eaziaia) (11)3 1(.23) 1Q.Z) (V4) 1(.5 1(13) EER TAPS JAGER TAPS ICED BEER DISPLAY BEER TAPS (POS EiliSIMEMEIMINW _ ........... .________......_... .____ __ L ' - •_11_ 1 , i N 1 41 - .. .......... ..... ........ ........ li .1 I u 14'-8" ELEVATIONS 1'-8" 1 # V-8" 11 2`-5" 11 I-8" GLASSES GLASSES GLASSE* FOOD WARMER 6n 4'-0" FILLER REFER to rn 4'-4" 1V-0" KAIRAK PIZZA PREP WIDRAWERS (REMOTE) WALKWAY 2'-5" CASEWORK 6'-0" 6 1 1 REFER ti 1 1 • " ' i141:40 • *,. !!!- ELEVATION KEY PLAN 3/16' 1•40" REFER - i I 1 ! _ --- --, ! , T - 4 * i I I I III■ M ... ......... ....... .: ........... 4 .1 1 ® *e` c.) .......... . ................ :. ................ T . ....... ., .................................... ....... , ............... .. - -1 ----------------- J 1- - ......------- T:_.7 IT El ii F 3 6-0" u. RANDELL STEAM! KAIRAK PIZZA PREP TABLE -I • HS WiFCT.43, SIDE SHIELD m 6. FS I, • • •• :;%; i H- 1 ,41 I I . .... ... ■ 10 , *t. 7 77 LI -.---,--..-.- KAIRAK PIZZA PREP 4'-O" 1 REFER FILLER 7 -errvoF O .KWPIA FEB RECEL L , 0 6 2008 SHT. # INDEX KC-1 EQUIPMENT PLAN KC 1.1 FLOOR PLAN KC-2 PLUMBING PLAN KC-2.1 BEVERAGE CHASE KC-3 ELECTRIC PLAN KC 4 ELEVATIONS & KFf KC-4.1 ELEVATIONS & KEY KC-5 HOOD DWG'S. KC-5.1 HOOD FAN DWG'S. KC-6 BAR PLAN SUBMITIAL SET 3 COMP SINK REV. ELEVATIONS ROUGH'S Do 07 - 26 - 07 U.O.N. DRAWN BY: Johnny Lee DATE: June 13, 2005 DEALER Arizona Rest. DUKES SOUTH CENTER. dwg REVISIONS A 5/24/07 B 5/31/07 C 06/21/07 GENERAL SPECIFICATIONS S/S 18 GAUGE 304 CONSTRUCTION s/s LEGS, SOCKETS & ADJUSTABLE FEET S/S 18 GAUGE SINKS S/S COMPLETE EXPOSED FABRICATION S/S SUPPORT CHANNELS FOAM INJECTED INSULATION RUBBER SOUND PROOF UNDERCOATING ALL BRASS DRAIN FITTINGS COMPLETE HARDWARE AND FTTT)NGS i e \ S National Bar Systems 16571 Burke Lane Huntington Beach, California, 92647 Tel: 714 -848 -1688 Fax: 714- 848 -2788 MODULAR BAR DIE WALL (NMDS) GENERAL SPECIFICATIONS S/S 18 GAUGE i304 CONSTRUCTION S/S LEGS, SOCKETS & ADJUSTABLE FEET S/S 18 GAUGE SINKS S/S COMPLETE EXPOSED FABRICATION S/S SUPPORT CHANNELS FOAM INJECTED INSULATION RUBBER SOUND PROOF UNDERCOATING ALL BRASS DRAIN FITTINGS COMPLETE HARDWARE AND FITTINGS 54.00 tr 7 24.00 13.40\ . 11 24,00 23.98 ��,� 54.00 44.99 r / / / ��•... 7.99 F � 174�.� • .,_ � 24.65 16 //) ' / ,7 d7 13,4 SCALE: 1/2 1'0" 48.00 NBRH- R2 -48- SSD -LT -PPW HIGH REMOTE BACKBAR REFRIGERATOR W/ S/S DOORS, UGHT & PRE -PIPED & PRE -WIRED CONNECTION (110V, 5A MAX, 13008TU, R22) 24,80 49,50 P 60- SP1 - CB -M CAB(N DR 0ABINET WED MITERED CORR. WI A10' HIGH SPLASH 24.00 72.00 NBRH- R3 -72- SSD -LT -PPW HIGH REMOTE BACKBAR REFRIGERATOR W/ S/S DOORS, LIGHTS & PRE - PIPED & PRE - HIRED CONNECTION (110V, 5A MAX, 18008111, R22) 339.18 (VERIFY) ,7L_ 19.90 ter' 339.18 (VERIFY) 15.50 -/ NHS -1 - SP1O-CB -N CASKET BASED HANDSINK W/ A 10' 581 SPLA91 k TIERED 144.00 (VERIFY) 72.00 NBRH- R3- 72- 55D-LT -PPW HIGH REMOTE BACKBAR REFRIGERATOR W/ S/S DOORS, LIGHTS & PRE -PIPED & PRE -WRED CONNECTION (110V, 5A MAX, 1800BTU, R22) PLAN VIEW OF UNDERBAR EQUIPMENT FROM ITEMS 110 THRU ITEMS 129 60.00 48.06 50,14 M, N408' gp515D 14/ 10 CADINE DRp11S\A 85.52�,� CDF RISGN� �I GN � 25.28 "MIL ) r//!I/.% / / //f / /! /I! // / / //ii / 1C 48,00 NBRH-R2-48-SSD-LT-PPW HIGH REMOTE BACKBAR REFRIGERATOR W/ S/S DOORS, UGHT & PRE -PIPED & PRE -WIRED CONNECTION (110V, 5A MAX, 13008111, R22) O 0 0 O 0 O s v =1• 0 8.0 0/- r ® DRAINROARD 1B• 12.00 0 0 O 0 0 0 g/8,00 O MIXER/DUMP STATION „r Sam LIINEZT PLAIN VIEW - KITCHEN ITEM NO. 101 24.90 NBRH- R1-24 -5SPD SSE 55RC - LT - PPW HIGH RETAOTE BACKBAR R WGERATCR W/ /5 DOOR, 5/5 50 ALL STAILESS STEEL CONSTRUCTION, LIGHT, PRE -PIPED t PRE -WIRED CONNECTION (1105, 5A MAX, 10000111, R22) ELEVATION OF UNDERBAR - A - wu NO W171. ELEVATION OF UNDERBAR - B - s xr n DRY GLASS STATION. 0 0 0 0 0 0 O o/— M OB o3d Ina MINIMWE H RECEIVED CITY OF FEB 06 2000 'J G':`IP „ l' "CENTc:r: LF LIP c: VVV t� Shear Size ARCH D KC -1 KC 1.1 KC -2 KC -2.1 KC-3 KC 4 KC-4.1 KC -5 KC -5.1 KC -6 EQUIPMENT PLAN FLOOR PLAN PLUMBING PLAN BEVERAGE CHASE ELECTRIC PLAN ELEVATIONS & KEY ELEVATIONS & KEY HOOD DWG'S. HOOD FAN DWG'S. BAR PLAN 3 COMP SINK REV. ELEVATIONS ROUGH'S 3 SUBMITTAL SET 2 1 1 8/06/07 8/06/07 7/26/07 7/12/07 KC -6 Scale: 1 FILTERCS) LIGHTCS) UTILITY CABINETCS> FIRE SYSTEMI PIPING � HGHG T TYPE QTY HEIGHT LENGTH QTY. TYPE WIRE GUARD LOTION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL 4 QUANTITY QUAN LOCATION 1 'SS BaFFte with HancRes 4 16' 16' 4 Incandescent Light NEI Left 990 3300 -0.635/ 2970 36' NO Sete LBS. 4 16' 20' 2 SS BnFFIe with I nci s a 16' 16' 4 Incandescent Light NO 4824 Ni0-2-PSP-F 11' DDD'Nor. L' 0.00'GD 600 Deg, 302ra 10' 29' NO 454 LBS. 5 16' 20' 3 SS Baffle with Handles 3 16' 16' 2 Incandescent Light NO 3 4824 ND-2 -PSP -F ND 231 LBS. 1000 10' 9' 4 SS BaFFIe with Handles 3 16' 16' 2 Incandescent Light Fix ND 430 55 Where Exposed ALONE HACK NO 233 LBS. 4 4824 NE-2 -PSP -F MOOD NO' MODEL LENGTH MAX. C1101CTNG TEMP. EXHAUST PLENUM SUPPLY PLENUM CONSTRUCTION F HOOD CONFIG. TOTAL ExH. CFM RISERCS) TOTAL SUP. CFM RISERCS) END TD END Rold WIDTH LEND. DIA. CFM SP. WIDTH LENG. DIA. CFM S.P. 4824 ND -2 -PSP -F 12' 0 .00'Non. 12' 0.00•00 600 D. 330 10' 31' 990 3300 -0.635/ 2970 36' 1361 0.231' 430 SS Where Exposed LEFT FRONT 1361 0.231' I 3 1 Front I 48' I 16' I 6' 8' 24' 2 4824 Ni0-2-PSP-F 11' DDD'Nor. L' 0.00'GD 600 Deg, 302ra 10' 29' 3025 -0599' 2722 430 SS Where Exposed RIGHT FRONT 3 4824 ND-2 -PSP -F 4' 0A0'Non. 4' 0.001JD 600 Deg. 1000 10' 9' 1000 -0,413' 800 430 55 Where Exposed ALONE HACK 4 4824 NE-2 -PSP -F 4' 0.00'Noe. 4' 0.00'03 450 Deg. 900 9' 9' 900 - 0.360' 870 430 SS Where Exposed ALONE N/A rH00D N0. ' AFFLE - TYPE GREASE FILTERS LENGTH w. HEIGHT RISERCS) GREASE ORAIN LEND, WITH REMOVABLE CUP rH00D N0. PIS. LENGTH WIDTH HEIGHT RISERCS) WIDTH LEND, DIA. CFM S,P. L Front 156' 16' Ee 10' 04' 990 0.174' 10' 24' 990 0.174' 10' 24' 990 0.174' 12 1 Front' 132.1 16' ( 6' 8' 36' 1361 0.231' 8• 36' 1361 0.231' I 3 1 Front I 48' I 16' I 6' 8' 24' 800 0,146' HOOD INFORMATION 483 3.0 Utility Cnhinet Hood #1 CAPTIVE - AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 NSF UL 710 & ULC710 STANDARDS E.T.L. LISTED 3054804 - 001 11.0 31.0- Ell LISTING DESCRIPTION BLOCK THE CAPTIVE AIRE MODEL ND HAS BKRN E.T.L. TESTED, LISTED, AND APPROVRT) TO EXHAUST A MINIMUM OF 200 CFM PER UNBAR FOOT OVER 600 DEGREE COOKING EQUIPMENT u.L, List rd Incandescent Light '-243 52.0 I. 52D 2' 0.00'Nan/12 0.00'00 tl Cut IC 0 PLAN VIEW - 12' 0.00' LUNG 4824ND -2 -PSP -F 2.6.0 L a4,a -- 5.0 J 0.gq'Nen. /4' DAD' pi AN VIEW - Hood #4 - 4' 0 00' LANG 4824ND -P -PSP -F Hood 02 11 efq OOD INFORMATION .0- ._9.0 ( PLAN VIEW - 11' 040' LONG 4824ND -2 -PSP -F 0.00'Non./4' 0.00' 24 r --.2A1- --1 I- II ILL Listed Incandescent LIGht 0 0 Hood 63 Id Cut Field Co UL I trd Inenndeseer,t Ught 33.0 I 66.0 1 1 0.00'Na J11' 0.00 0 a 0 3,0 1.0 4 .0 1 .0 REMOTE MANUAL PULL STATION REMOVABLE STAINLESS STEEL SERVICE BOOR AGENT TANK ANSUL FIRE SYSTEM BOX MICROSWITCH WIRES ARE LOCATED IN A ROUND BOX ON THE SIDE OF THE FIRE SYSTEM. S EE NOTES BELOW NOTES: 1) TO COIL OF SHUNT TRIP BREAKER TO SHUT OFF ELECTRIC COOKING EQUIPMENT. 2) TO COIL OF MUA ?' TOiR STARTER TO SHUT DOWN MUA FAN. 3) TO BUILDING ALARM SYSTEM. SPECIFICATIONS: ND -PSP MODEL THE MODEL ND IS A WALL CANtPY EXHAUST HOOD. VENTILATOR SHALL BE COMPENSATING WITH THE ADDITION OF A PERFORATED SUPPLY PLENUM CPSP), SUPPLY AIR SHALL DISCHARGE THROUGH PERFORATED PANELS AT THE BOTTOM OF PLENUM. THE HOOD COMPONENTS SHALL BE FABRICATED OF TYPE 430 STAINLESS STEEL, 43 OR 04 POLISH. ON ALL EXPOSED SURFACES, CONSTRUCTION SHALL BE IN ACCORDANCE WITH NFPA 96. THE HOOD SHALL BE PROVIDED WITH HANGING ANGLES ON EACH END OF THE HOOD AN ADDITIONAL SET OF HANGING ANGLES WILL BE PROVIDED FOR FEUDS GREATER THAN 12' IN LENGTH, THE HOOD SHALL DE FITTED WITH U.L. CLASSIFIED ALUMINUM BAFFLE FILTERS WITH HANDLES, EACH FILTER SHALL BE EASILY REMOVABLE FOR CLEANING. THE FILTERS WILL DRAIN THE GREASE INTO A SLOPED GREASE DRAIN SYSTEM WITH REMOVABLE 1/2 PINT CUP FOR EASY CLEANIING, HOOD LIGHTS SHALL BE UL LISTED AND NSF LISTED FOR USE IN COMMERCIAL COOKING HOODS. EACH FIXTURE WILL ACCOMODATE A 100 WATT INCANDESCENT BULB. HOOD DIMENSIONIS SHALL BE AS SHOWN ON DRAWINGS. DECTECTOR DE,4 RELEASE/ BRACKET ASSEMBLY DUCT PROTECTION NOZZLE PLENUM PROTECTION NOZZLE TYPICAL ANSUL R -102 SYSTEM LAYOUT BROWN NORMALLY CLOSED M ICROSWITCH BLACK = NORMALLY OPEN RIO = COMMON "ITN FIRE SYS'TE'M COC ' D C r@ NC = CIRCUIT C .1 NO = OPEN WITIJ FIRE SYSTE3! FIRED CA NC= OPEN C NO = CIRCUIT • EACH MICROSWITCH IS RATED FOR 15 AMPS, 1/3 HP 125 OR 250 VAC, WITH 1/2 AMP B 125 VDC AND L/4 AMP 8 250 VDC, HANGING ANGLE 3' STANDOFF IT IS TFE RESPONSIBILITY OF THE ARCHITECT/OWNER TO ENSURE THAT THE HOOD CLEARANCE FROM LIMITED - COMBUSTIBLE AND COMBUSTIBLE MATERIALS OS IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS OPTIONAL PRE -WIRED ELECTRICAL TERMINAL BOX WITH TERMINAL STRIPS. 3-PHASE C.UNTACTORS AND OVERLOADS FAN AND LIGHT OF APPLICABLE) CONTROL PANEL SPECIFICATIONS PERFORATED SUPPLY PLENUMS ` % E70 - 1AlJST RISER EQUIPMENT BY OTHERS 100W VAPORPROOF INCANDESCENT LIGHT 2.75' 16 33' MIN 4e' NAX R4• WIT SECTION VIEW -- MODEL 4824 -NA- -2 with PSP Accessory THE RESTAURANT FIRE SUPPRESSION SYSTEM SHALL BE THE PRE - ENGINEERED TYPE WITH A FIXED NOZZLE AGENT DISTRIBUTION NETWORK. IT SHALL BE LISTED WITH UNDERWRITERS LABORATORIES. II .(UL) THE SYSTEM SHALL BE CAPABLE OF AUTOMATIC DETECTION AND ACTUATION WITH LOCAL OR REMOTE MANUAL ACTUATION. ACCESSORIES SHALL BE AVAILABLE FOR MECHANICAL OR ELECTRICAL GAS LINE SHUT-OFF APPLICATIONS. THE EXTINI[.UISHING AGENT SHALL BE A POTASSIUM CARBONATE. POTASSIUM ACETATE -BASED FORMULATION DESIGNED FOR FLAME KNOCKDOWN AND SECURENENT OF GREASE RELATED FIRES. IT SHALL BE AVAILABLE IN PLASTIC CONTAINERS WITH INSTRUCTIONS FOR LIQUID AGENT HANDLING AND IISAIE, THE REGULATED RELEASE MECHANISM SHALL BE COMPATIBLE WITH A FUSIBLE LINK DETECTION SYSTEM. THE FUSIBLE LINK SHALL BE SELECTED AND INSTALLED ACLTJHDING TO THE OPERATING TEMPERATURE IN THE VENTILATING SYSTEM. THE FUSIBLE LINK SHALL BE SUPPORTED BY A DETECTOR BRACKET/ LINKAGE ASSEMBLY. t40?yO3d SUPPLY RISER WITH VOLUME DAMPER 23.55 OPEN STAINLESS STEEL PERFORATED PANEL Chi OF TUKWILA FEB 0 6 2008 *RDD MD NUTS TO DE SUPPUID BY INSTALLNG CONTRACTOR FUNDING ANGLE IS PRE - PUNCHED AT FACTORY HANGING ANGLE DETAIL HOOD STYLE C A N 0 P Y EXHAUST ONLY WITH NUA B AS CH K L F EXHAUST ONLY viral NUA CONDENSATE DIM FROM 1.75° 135 1.75" 1.75" FILTER DETAIL DIM FROM (24 11.25" 2.75" 15.0 2.75" DIM FROM FRO (30 N H) 5.25" 2.75" 5.25" 2.75" 10.50" HANGING ANGLE LOCATIONS ECUUST CFI= LENGTH OF HOOD X CFN/UN.PT. (LOAD) SUPPLY CFM EXFIAUST CFM x PERCQIIAOE REQUIRED TOTAL DUCT AREA -144 X DUCT LENGTH- CFM FPM(•) TOTAL DUCT AREA DUCT DEPTH G;IVDAMZ VE1.Ts.1IDR DUCT 51213 cmCuA>FD UANGAE OiA115T VELOQIY OF 1600-1 600 FPM AND A SUPPLY VELOCITY OF IMO FPM. CALCULATIONS UTILIZED CAPTIVE-AIRE HOODS ARE BUILTIN COMPLIANCE WITH: • NFPA ¢96 • NSF • BO.0.. #33 • ETL 3054004 -001 • IO.B.0. 4416 • SR= PST B ES1 NO. 93137 • Ui 710 5 ULC710 STANDARDS BUILDING CODES COMBUSTIBLE .111 • .J1.. •. _•_. REDUCTION SYSTEMS AVAIL ABLE AS FOLLOWS: NON &1 $IIBLE LIMITED CDNBU5BBLE CLE REDUCTION SYSTEM NONE REQUIRED 3' UNINSULATED STANDOFF 3' IMSUWID STANDOFF CLEARANCE TO COMBUSTIBLES INSTALLATION 1. ALL ELECTRICAL 'FEW CONNECTIONS AND RELATED INTEVONNECT1ONS BY ELECTRICAL CONTRACTORS. 2 AL.. PLUMBING 'MD' CONNECTIONS AND RELATED MERCONNECTICNS BY PUWMBINO CONTRACTORS. 3. WRONG BRACKETS LOCATED AND WEL0E0 AS SHOWN ON PUNS ALL OTHER HANGER MATERIALS MENDED BY WSTNJJNG CONTRACTORS. 4, All O ME L CONTRACTORS'S D. DUCT PER 6. COOICNO EQUIPMENT TO SHUTOFF Pi EVENT OF FIRE 6. EXHAUST FANS TO TURN ON IN EVENT OF FIRE. 7. ALL LIGHTS FTXNRE SHOWN INSTALLED RY CAPTIVE -ARE ARE FACTORY PREYMED. INIERCONNECI%SNS SEMEN HOODS AND TO SWTNOIES BY ELECTRICAL CONTRACTORS. d LAAPS FOR LIGHT FDO BY INSTALLING CONTRACTORS. B. SEISMIC RESTARTS ARE RESPON50LLBY OF WALLING CONTRACTOR 10. INSTALLING CONTRACTORS ASSUME ALL RELATED REPONSIB1UTY FOR VERIFICATION OF DIMENSIONAL DATA CONTAINED ON THESE DOCUMENTS FOR ACCURACY, INTEGRATION, 11413 ADMINLSTOA01ON OF CODE REOUIROCENIS IN EFFECT PRIOR TO ANY RELEASE FOR PRODUCTION OF EQUIPMENT SHOWN. g 1 1 I Q :KA HOC10S MUST BE O• xi..:,. mat KITCHEN. 12 KITCHEN SHAH BE NEGATIVE WIT! RegECT TO DINING AREA. 13. RESTAURANT SHALL BE POSITIVE WITH RESPECT 1D AMBIENT PRESSURE. ADDmoj. 14. WRITTEN HOOD DR.ETLSLONS HAVE PRECEDENCE OVER SCALE 15. SIGNED AND 'APPROVED' COPES OF THIS DOCUMENT NNFNCOCAIENT OF AABR PRIOR TO GENERAL NOTES RESISTANCE VS. AIRFLOW- .2 :x140 MW 2,07:4 ne/s .1. m M A nzxr. 46 RESEARCH PRODLKIS common l'een -Gard Baf le Type Filters are UL Classified Grease Extracting Filters. MBA # 168 -78 -M Alominu:m 1lfEA # 247 -96 -E. Stainless Steel REVISIONS DESCRIPTION ELT!: A QA c ® O o oz Cb DATE: 7/11/07 1 DRAWN BY: R. STEWART SHEET# 1 of 1 SCALE: 1/2 = 1 Ft HOOD DETAIL PLAN 2804 GRAND AVE. SUITE 202 EVERETT; WA. 98201 PH: (88B)-338-5225 FAX:025)-212-6998 EMAIL: rag85@captIveafr.com FAN Uti!T FAN UNIT MODEL it EXHAUST FAN SUPPLY FAN SWITCHES ROOFTOP STARTERS OPT MN FANS CONTROLLED LOCATION QUANTITY TYPE VOLT FLA BLOWER HOUSING TAG CFN SP. RPM H.P. 0 VOLT FLA Exhaust 3 10.000 208 27.9 I1 3/4 11 7/16 N/A 3/4 208 27.9 4 36 Supply 3 5.000 208 141 20 1/36 29 118 16 9/16 2 A4-D1000-920 M 12 14 11/16 13 U8 1 165 10 4 36 1113 920 A4-81000 10 3/4 7302 L000' 641 5.000 3 208 141 NO, TAG PACKAGE It LOCATION SWITCHES ROOFTOP STARTERS OPT MN FANS CONTROLLED LOCATION QUANTITY TYPE 0 H.P. VOLT - FLA 1 W 31111083 Utility Cabinet Left Hood # 1 Utility Cabinet Left Hvod 4 1 1 Light 1 Fan a I/4 Exhaust In Fire, Lights out In Flre Exhaust 3 10.000 208 27.9 I1 3/4 11 7/16 N/A 3/4 91 10 4 36 Supply 3 5.000 208 141 N0. ON ITEM SIZE 1 4 1 Curb 4.000'' x 60.000'L x 20,000'H Hinged 2 4 2 Curb 42.000"V x 42000'0. x 20.00011 Insulated V Nall 6.000 - W x 42.000 x 20,030'H FAN EPTION U - ➢escr) EXHAUST Rubber Vibration Isolators for BI Utility Sets (set Of 6) GREASE CUP Exhaust Fan Grease Cup GDELHI) WALL MOUNT Motorized Backdraft Dnnper for A4 -D Housing Z F FAN UNIT TAG EXHAUST SUPPLY GREASE CUP GRAVITY DAMPER WALL MOUNT SIDE DISCHARGE GRAVITY DAMPER SIZE DAMPER MOUNT 1 V YES APPROX dTit4 'IN W FF 1130 23 5/8 2 a I/4 27 3/4 15 1/4 21 5/16 13 3/16 U YES I1 3/4 FAN NM BTU' TEMP. RISE GAS TYPE 2 428919 55 deg F Natural FAN NM AU D E F G H K U P S T V DIAT APPROX dTit4 'IN W FF 1130 23 5/8 11 5/16 a I/4 27 3/4 15 1/4 21 5/16 13 3/16 U 17 114 I1 3/4 11 7/16 N/A 3/4 91 10 4 36 5112 30 1/16 13 9 7/8 33 1/4 20 1/36 29 118 16 9/16 12 7/16 21 119 M 12 14 11/16 13 U8 1 165 10 4 36 1113 Su 13/16 14 3/8 10 3/4 34 141 20 1/16 29 1/8 16 5/16 14 3/8 21 1/8 11 1/2 14 11/16 34 I 170 10 4 36 8115 31 13/16 IS 3/4 12 35 3/8 20 1/16 29 1/8 16 946 15 7/8 21 118 11 1/2 14 10.16 15 i/4 1 180 10 4 48 OM 34 1616 17 518 I I/8 36 1/2 22 31 16 7/16 17 3/8 2l 343 U 112 14 11/16 16 3/8 1 3/16 200 10 4 48 HUH 35 13116 19 318 14 1/2 37 7/0 22 31 16 9/16 19 3/8 21 1/8 U 12 14 11/16 17 3/4 1 3/16 220 111 4 48 HMO 42 15/16 21 1/4 15 3/4 46 7/16 28 40 7/8 25 1/4 21 1/4 27 11/16 14 5/8 22 3/4 19 3/4 1 3/16 405 10 4 60 1122 44 3/8 23 5/8 17 5/8 48 546 213 40 7/8 25 1M 23 5/8 27 11/16 14 5/8 22 3/4 at 5/8 1 3116 430 10 4 60 8124 49 12/16 26 19 3/8 51 5/16 32 46 L/2 29 15/16 26 20 1546 18 946 25 12 23 3/8 1 7/18 499 10 4 60 1127 51 7/16 2S 5/2 21 1/4 53 346 32 46 1/2 28 1545 28 5/8 28 15/16 18 5/16 2S 1/2 a 3/8 1 7/16 525 10 4 60 3130 64 1146 31 3/4 23 5/8 57 5/3 43 5/16 64 3/4 43 3/8 31 3/4 32 17 41 28 9/16 1 11/16 800 10 4 69 8133 65 5/8 34 710 26 60 43 546 64 3/4 43 343 33 32 17 41 30 15/16 1 11/16 875 10 4 69 8136 68 13/16 38 5/8 28 3/4 62 3/4 43 7/16 64 3/4 43 3/8 38 3/4 32 17 41 33 1146 1 15/16 915 10 4 69 loatellstlon Wiring ..08 MANE 0.k 8 Chortler louse Revked DATE 11/1512007 BRAVING N10485R 0P603279 -2 .1738 NLIXHER 630279 MOREL .4- 81000 -201 120 V 1 PH. 240 V 1 PH. 208/483/600 V 3 PH inssoncalialsons M ER conduit 2f .1. 3 y C3-m CsnosapsiTs9p 0=10 #11 if in-es es 'OE 6 53 111 a i 01-14 ST -01 ''.(9' AP L« Pfitil L01e1 1' Lvaai� :r M cRa1TR�BRI, See above detail IL ■ e 5 20 se go 4 88' G 5 4 r Ku 8-- os 0 VTm WI 1lOL�S yOgF rn r. 02 3-A0 TV - YELLOW R ETN4 32 - 001 HA FROM V - GMAT PR Lv. ea - NeeLE NY 8 w Pt - Pie. xii / Direct Fired Heater T%rIng JGB NAME Duke's CY8•der ilRUS ReV1se8 DATE 11/15/2007 BRAYING M11®ER 076482)5 - .1711 N11MB[R 588275 0 -2 21 143DEL 22-2 14 ST-HI U -01 3:3 fr.a 1222 1•e1 D•.P.. 2ab'0 M 3421wr2. 14.2. 1222212 *�CVOWE M ER 2f .1. 3 y C3-m 3YE nog EE E 9 Gg a[I PF WI t t t 1 p 1 ' ; VANS n ;NgNUH IN; 4 in-es es 'OE 6 53 7 01-14 ST -01 ''.(9' AP L« • c TS O3 STSS -0,� HI :r u C eT IL .. • 5 20 se go 4 88' G 5 4 VTm WI ., , ®GT O E 52 p.r. x D a r = ESE-0 212-91 >R NA/ spy 1P 5 VOLTS 3 Ohs 216 V C aW LU'l�' ROOM. MOAT 0272 AP 7 00' YV a. >a 9 3' -3011 VW120010 300130 ' 31101322 �' a 71100.0.0 74 Ale 000 111 At SsHLT 1G10a m TFMma.L 0 310308 333.0. rn.cnml vier/ rmr. HE AMN TV - YELLIN A ELE 9t -016ON SR BRIM GT - GRAY CO MAZE PR - PZR+LE P1 RED Pt - Plle VX MITE e2 Pl \ f;11 02 Ts-m VA-OH FAII INFORMATION FAN ACCESSORIES OPTIONS FAN 131 SERIES RESTAURANT DUTY UTILITY SET SMART CURB ASSEMBLIES OPTIONS PEAT SLINGER SHAFT SEAL EMERGENCY DISCONNECT SWITCH Vt0RA11VN ISM - A10RS GAS FIRED MAKE -UP AIR UNITS ELM= FULL AFCA CLASS I OPERATION - VENOM MOTOR COVER FOR WEATHER PROTECTION - 18.762 LISTED FOR RF_STAHANT 1a)TY - LPHLAST DIStr1ARGE MEETS 610 AWAY FR31 FLOOR - cO1TIMEIMLY YF1_BP:11 HOUSING CLEANOUT MUR WITH LATCIES FROVITE EASY ACCESS WIIHOIT TOOLS - 2' GREASE DRAIN OILL NUT CLOG MODULAR OUTDOOR DOWN DISCHARGE DIRECT FIRED HEATER DIM 'B' I L L DIM 'A DIM DISCHARGE OPENING FLEX CONDUIT FOR FIELD WIRING -I DIM 'F' AIRFLOW 4F✓■ BIM S � - ➢IM 'N' DIM I i J DIM 'R" I CURB OUTER WALL SERVICE LIFTING LUGS DISCONNECT �4 PLACES SWITCH 0 Wa/m FAN BASE CURB PLATE CLEFT) FAN PLATE (LEFT) HINGE KIT DETAIL GREASE BOX (OPTIONAL) GREASE PIPE (OPTIONAL) FAN DETAIL A' CURB FAN IN CLOSED POSITION ELECTRICAL PACKAGES F W F - TEAL 6 RESTAURANT DUTY UTILITY SET DDR7(SEIAL DATA FF S-1 OPTIONAL SUPPORT RAILS NOTE: IF WALL MOUNT PREWIRE, OR FIELD INSTALLED FIRE SYSTEM M/CROSW/TCH TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED BP11T POEM 3 818€. 3 MUSE Va.TS - MK•KER PROS . _�, 8 23 03 FAX 1 8170EL 7 i IJ LPR.Y EMI 1 4141 rre 1 :T. MBE E : 3 COL wave 10000 MARINO FOR 12' X la" 6' &NM GOVFRED _L CTRICAL 9O 14110 Mr 101TA0 RELAY NE 8.1.1 K - LT. 160 00900LS 11225e5x1701 Cy00 FIR 11 FIR FIEI..D llw0H F - air CINT81ACTS RR ONY m rmo 7.A I •x 3 ELK ""LACTIi.ACIED FACTS RY 1.32030 FIELD VIKING /00221211103 0111 FIRE SYSTE. ••i 21 ® 10[RaSYnal -1•11:1-0. I EvutlT. 1 SUPPLY 1 60fl. T FAN SVS504 a qp [2171 = r r •..1'71_17 j 4 1- DIM DIM ROOF OPENING ALL DIMENSIONS ARE NOMINAL AND GIVEN IN INCHES. UNIT INFORMATION. 2' SMALLER THEN CURB DIMENSION. 20 IN HIGH EQUIPMENT CURB CURE/RAIL COMBINATION USED ON UNITS WITH 20' AND 25' BLOWERS 20 IN HIGH EQUIPMENT CURB B. RAIL DIM 'J' - MU D.250 -G10 1.500 -G10 ➢.500 -G15 UN T DIMENSIONS E.751 -G15 2.750 -GIB 13,1000 -GIB 81000 -951 D.1500 -920 D2000 -925 112500 -925 WEIGHT C ➢ E CURB 1 K DISCHARGE OPENING P R S 595 LBS ►L eL�JL'•1^ -">F4 c7LlCCCOQ_leylALIMIAnt ij;;liinr. S•li[7 60O LDS ��LWQcEC� ®0� "1' 1 f.SriT.i 810 LBS " e'YIIe7Q:7kI.IMUM j »]MSTRIK ATc Ci =LIMBLIQM[ .MFIIIIk�T1 815 LBS 81 LDS N- Etaki - prozerLE itieDriTl- E AR 1=I MOMIT ILIONl Oraienri 975 LBS E IIlNI F[0. - •MEEIMMIREOMEM CZ/13ic7iT.1 ®0 ®m ]',�fUayii� 980 LBS [ )■.' -1Ei'L�.I Tl•1k7IMMF : E 1MIlre- Yl3k7f1'iM in MCVErtMRgL.Yiri 1635 LB• Fit= IIIf # 'T_LrlfTi c( 1C•[ mm]I-iIQrliMriiiikTZriCy[S7-mrlu [i- i5sTAL1 OE:$ILAI 7F 6.71 • 1650 LB E�10:ffLIBECELIM'ZAIMEMEIZZNE1 'E 2160 LESIMMFh. 1 - / -1/: -1/4 1- 1 - /4 - /1- - /4 1 - /1- 1- 2175 LB' 9 -3/16 58 -3/8 / 1 -11/1- 1 - / 53 -1/8 5 -1/4 /1 -3 /IF 13 -3/4 76 -7116 52 -3/4 125 -3/16 31 -3/8 31 -3/8 10- 11/1612 -7/8 DIM -` MODEL 17.250 -G10 D.500 -G10 0- 500 -015 2.750 -G15 2.750 -G18 D1000 -G18 0.1000 -920 M.1500 -920 D.2000.925 0.2500 -925 BTU RANGE CMBH) BURNER LENGTH BTU LOW BTU HIGH 18' 24' 27.5 36.6 825 1100 6' 18 275 314 12' 12' 18 550 IS 550 18' 27.5 825 GAS PRESSURE MIN MAX 7' WC 7' WC 14' WC 14' WC 7' WC 14' WC 7' WC 14' WC 7' WC 14' WC 7' WC 11' WC 24' 30' 48' 60' 36.6 45.8 73,3 9L6 1100 2200 2750 GAS CONNECTION 'T' (NPT) 3/4 1 CFM RANGE FILTER 50.7E 6 QTY MIN MAX 2500 6000 20'825 (3) 3500 3500 Bo8D 8000 16'x20'82' (A) 16 x20 - x2" (6) 1000 3000 16'x2S'x2' (3) 1000 0000 2500 6000 16'820'x2' (3) 20 "x25'x2' (3) 7' WC 5 PSI -111 7' WC 5 PSI 7' WC 5 PSI MAX. FILTER VELOCITY 63000 CFM = 572 FPM 03010 M . 72 FPM 66000 CFM = 696 FPM 96000 CFM = 696 FPM 98000 CFM = 762 FPM 98000 CFM = 76E FPM 913000 CFM = 743 FPM 213000 CFM = 743 FPM @21000 CFM = 913 FPM 021000 CFM = 913 FPM 6000 13000 10000 21000 10000 21000 16.8 I• • (10) 16'x20'x2' (10) 20'x25 "x2' (8) 20'x25'x2' (2) 1 - 114 1 -1/4 1-1/2 1 -1/2 REC C OF FEB C FAN IN OPEN POSITION GREASE BOX ATTACH GREASE BOX COVER TO THE CURB 3' BELOW TOP EDGE OF CURB. USING (3) LONG (3/4' LG.) SCREWS AS SHOWN. INSTALL GREASE PIPE AS SHOWN. GREASE PIPE MVED r f y{ VP(..A 6 2000 r'i = NITC: ; CURB GREASE BOX COVER GREASE BOX INSTALLATION 1. A PRE -WIRED ELECTRICAL CONTROL PACKAGE SHALL BE PRONOEA TO OPERATE THE 1000 001175 AND FANS. 2. PACKAGE SHAT- C011185T OF SWITCH PANEL WITH LIGHT SWBNCH(ES) AFU RED -UGH ED FAN SIYIT51( STARTER/ OVERLOAD ASSOIBLY FOR EACH FAN(OPTIONAL). NUMBERED INPUT /OUTPUT TERMINAL STRIPS. AH0 A TERMINAL FOR DOUBLE -DUAL FINE SISIEM MKAOSWITCH CONNECTION. 3. ONE RELAY IS WIRED TO MICROSWITCH ON FIRE SISTEM) FOR SUPPLY FAN SFRIT00WN AN0 OTHER RELAY FOR ADDTTIONA. FIRE SYSTEM ACTNATED DRY CONTACTS. 4. ELECTRICAL CONDUIT DROPS FROM THE FANGS) SHAT BE CONNECTED TO THE NUMBERED TERMINAL P. CONDOR REIYEEN THE PRE -WIRE PACKAGE AND FAN(5) SHALL BE SUPPLIED BY THE ELECTRICAL 00078T .TOR ELECTRICAL PACKAGE NOTES ATTENTIDM INSTALLER SHOULD SUPPLY ENOUGH ELECTRICAL CORD TO LET FAN MAKE COMPLETE SWING. SHEET# 1 of 1 DATE: 7/11/07 DWG. #: 1 DRAW R. STEWART SCALE: 1/2" = 1 Ft HOOD DETAIL. PLAN I