Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-037 - WESTFIELD SOUTHCENTER MALL - JOHNNY ROCKETS
JOHNNY ROC 2600 SOUTHCENTE FC -1 STS MALL Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC -10/06 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2600 SOUTHCENTER MALL TUKW MECHANICAL PERMIT JOHNNY ROCKETS 2600 SOUTHCENTER MALL, FC -1 , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: RICHARD HERMAN Address: 6009 MELROSE AV , LOS ANGELES CA Contractor: Name: WESTWOOD CONTRACTORS INC. Address: 200 S 333RD ST #244 , FEDERAL WAY WA Contractor License No: WESTWCI088BF Value of Mechanical: $25,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * continued on next page ** M08 -037 Permit Number: Issue Date: Permit Expires On: DESCRIPTION OF WORK: EXHAUST AND MAKE -UP AIR SYSTEM AND HEATING AND COOLING SYSTEM FOR FOOD COURT RESTAURANT Phone: Phone: 323 465 -7066 Phone: 206 661 -0800 Expiration Date: 09/11/2008 M08 -037 05/02/2008 10/29/2008 Fees Collected: $451.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP/1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 05 -02 -2008 Permit Center Authorized Signature: Signature: Print Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us v3/.4#- O Permit Number: M08 -037 Issue Date: 05/02/2008 Permit Expires On: 10/29/2008 Date: 0 I hereby certify that I have read and x• ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied . 't , whether specified herein or not. The granting of this permit does not p esume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe . o r ance of y c rk.I am authorized to sign and obtain this mechanical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: I MC -10/06 M08 -037 Printed: 05 -02 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: 2600 SOUTHCENTER MALL TUKW JOHNNY ROCKETS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 9: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: M08 -037 ISSUED 02/12/2008 05/02/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 11: Type 1 hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur, The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods.(IMC 507.2.1.1) 12: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 13: Local U.L. central station supervision is required. (City Ordinance #2051) 14: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class IC rated portable M08 -037 Printed: 05 -02 -2008 extinguisher. (IFC 904.11.5) • O City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 20: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 21: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 22: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 23: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -037 Printed: 05 -02 -2008 Signature: Print Name: doc: Cond -10/06 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance work. M/k Date: - �-�f %(5i ordinances governing or local laws regulating M08 -037 Printed: 05 -02 -2008 I CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 lutp://www. LI. why i lama. us • • Building Permit No. Mechanical Permit No. V D 1 0' Plumbing /Gas Permit No. 1( — 0 Public Works Permit No. f7o�- 035 Project No. (hi�r office e4 only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. • * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: c 3(0 d26 — Q e I o Site Address: 200 SnMt-ICEt4Tt Q it AlL Suite Number: ' 1 Floor: 2. NA Tenant Name: ,J J .I 0.1 2.ft Ctl (gc I.44atJn(,JK F Mil New Tenant: [ " Yes ❑ .. No Property Owners Name: (.LESZrtii .Q (cap Mailing Address: (1 Lt^I i to i L & u I! (3L. mat Flt, OR L JX ,&hl(,F.(ES (City CONTACT PERSON - who do we contact when your permit is ready to be issued Name: 2 t fl -124M 14 Q.t 4.L Mailing Address: ( nal Mr.L204T AVE. E -Mail Address: RR e f,SI4 ALGA - CnIM Company Name: Orr .t PL ( :"TM Company Name: IL.EhL a tJ t . Contact Person: ( U, tC� 111 Q:.Applicaiious`.rorm,- Applications On Li, '3-200h - Pconii .ApphcauonJoc Kcv,cd 9.201)6 hh Day Telephone: t3134C6 104 L Las 4146eits CA ctmats City State gnn2S' Zip State Zip Fax Number: (%t3 - aO& 6 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Mailing Address: State Zip Cit Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Mailing Address: I .4 STaMECOAC44 MIL CAN) nu t C& 6 113.01 City \\ State Ltd, Day Telephone: CBI bJ ci - 4219 E -Mail Address: Fax Number: ( N(8) gig-4321 ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Page I of 6 BUILDING PERMIT INFORMATION - 206 - 431 -3670 W Valuation of Project (contractor's bid price): $ I O 060 GI I &IACM Existing Building Valuation: $ Scope of Work (please provide detailed information): TGI.IA.N."� (P1KO\X FM. f To A a84 sizt. FL FOOD Casa' splice Will there be new rack storage ❑ Yes No If yes, a separate permit and plan submittal be required. PLANNING DIVISION: Single family building foot nt (area of the foundation of all structures, plus any decks over 18 inches '%d overhangs greater than 18 inches) *For an Accessory dwc g, provide the following: Lot Area (s *Provide Floor area of principal dwelling: Flo area of accessory dwelling: umentation that shows that the principal owner lives in one of the dwellings as his or he® rimary residence. Number of P ng Stalls Provided: Standard: Compact: Handicap: Will there 13c a change in use? ❑ Yes FIRE PROTECTION /HAZARD e US MATERIALS: Vr Sprinklers Automatic Fire Alarm • • Provide All Building Areas in Square Footage Below ❑ None ❑ Other (specify) ❑ No If "yes ", explain: Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No if ,yes', attach list of materials and storage locations on a separate 8 -1/2 ' x 11 paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. o .'Applica Boni f onm- Applicuduu, On .ini '.>onn • P,nnit .Applicunun.doc kn, -i -nd• 9•20t), bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure � Type of Construction per IBC Type of Occupancy per IBC 1 itl Floor 2nd Floor S i: 7 1PC 1 STRIA l3 3 Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck BUILDING PERMIT INFORMATION - 206 - 431 -3670 W Valuation of Project (contractor's bid price): $ I O 060 GI I &IACM Existing Building Valuation: $ Scope of Work (please provide detailed information): TGI.IA.N."� (P1KO\X FM. f To A a84 sizt. FL FOOD Casa' splice Will there be new rack storage ❑ Yes No If yes, a separate permit and plan submittal be required. PLANNING DIVISION: Single family building foot nt (area of the foundation of all structures, plus any decks over 18 inches '%d overhangs greater than 18 inches) *For an Accessory dwc g, provide the following: Lot Area (s *Provide Floor area of principal dwelling: Flo area of accessory dwelling: umentation that shows that the principal owner lives in one of the dwellings as his or he® rimary residence. Number of P ng Stalls Provided: Standard: Compact: Handicap: Will there 13c a change in use? ❑ Yes FIRE PROTECTION /HAZARD e US MATERIALS: Vr Sprinklers Automatic Fire Alarm • • Provide All Building Areas in Square Footage Below ❑ None ❑ Other (specify) ❑ No If "yes ", explain: Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No if ,yes', attach list of materials and storage locations on a separate 8 -1/2 ' x 11 paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. o .'Applica Boni f onm- Applicuduu, On .ini '.>onn • P,nnit .Applicunun.doc kn, -i -nd• 9•20t), bh Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 I - IP /1,000,000 BTU Suspended/Wall /Floor Mounted I- leater Ventilation System Wood/Gas Stove 30 -50 HP/1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to 1- leat /Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator - Comm /Ind MECHANICAL PERMIT INFORMATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: O -1, r Mailing Address: City Stale Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): s 2S 0 no Scope of Work (please provide detailed information): At■ C.,X( -RAUST Af ■4I t AtL - up A . M q ty► 4 t .• •t • S.,- l <TG4 S •(� L A L &) Fobn COurrT AT 71.41: .SCA11>-4CcTa4 MALL Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas ....El Other: indicate type of mechanical work being installed and the quantity below: `Arprcnlionsromm,-Appii,au,ni, On Liu,:3.200,, • I', 11111i Appliceiion Joi Ft; .i,,,l- 9 -2006 bh I'aac 4 of h PUBLIC WORKS PERMIT INFORMATION —206- 433 -0179 Scope of Work (please provide detailed information): Water District ❑ ...Tukwila ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ Sewer Use Certificate Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Ri -of -way Use - No Disturbance El ...Construction /Excavation /Fill - Right -of -way Non Right -of -way ❑ ...Total Cut ❑ ...Total Fill ❑ ...Sanitar Side Sewer ❑ ...Cap or Remove Utilities El ...Fronta Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water FINANCE INFORMATI Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Water Meter Refund/Billing: Name: Mailing Address: Call before you Dig: 1 -800- 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. cubic yards cubic yards o .A err .itio,,.rein,,,- Appr..u,,,,. Lim • N_,,,,nt Applicato,,, d it ii r.c 9 -200h bh Water District #125 ❑ .. Highline ❑... Val El .. Renton ❑.. Sewer r' ailability Provided .. Right- .. Rig. /.. ❑.. Sto Septic System: El On -site Septic System For on -site septic syst provide 2 copies of a current septic design appro by King County Health Department. Submitted with Application (mark boxes which appl ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance 0 .. Easement ❑ .. Abandon . `•tic Tank ❑ .. Curb Ct ❑ .. Pave _=` "nt Cut ❑ .. Lo' ; ed Fire Line ❑ Permanent Water Meter Size . WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ .. Sewer Main Extension.. Public Private _ ❑ ...Water Main Extension, ... Public Private ❑ .. Geotechnical Repo ,' ❑... Tratfic Impact Analysis ❑ .. Maintenance A_, <' ment(s) 0...1-Hold Harmless (SAO) ❑...Hold Hannless (ROW) in Flood Zone Drainage Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment way Use - Profit for less than 72 hours f way Use — Potential Disturbance ❑...Deduct Water Meter Size Name: Day Telephone: Mailing Address: City Day Telephone: City ❑ .. Renton ❑ .. Seattle ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding Slate Lip State Lip Page 3of6 Date Application Accepted: D � r t [ !� t/ b �i►1 Date Application Expires: �5 1 ( , i of l.l Staff Initials: I PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. BUILDING OW Signature 6_,4' Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The expnsion shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). - I HEREBY CERTIFY THAT l HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED to APPLY FOR THIS PERMIT. ORAUTHORI 1 AGE Q: \Apphcatumsllonns- Applications On Line'3 -200h - Penult .Appliemlun.doc lined: 9 -20Oh bh Print Name: MA //: Mailing Address: 633 71 Date: 1. :10 0 Day Telephone: 7 - — e-, z' - 2/ k lit I/L - 9e) 8 City State Zip Page 6of6 Fixture Type: Qty Fixture Type: 11/ Fixture Type: Qty _... Fixture Type: Gas piping outlets Qty Bathtub or combination bath /shower Drinking fountain or water cooler (per head) % ^ ash fountai Bidet Food -waste grinder, commercial .— Rec.,tor, indire waste Clothes washer, domestic — Floor drain Q Sinks — Dental unit, cuspidor Shower, single d trap — Urinals --' "' Dishwasher, domestic, with independent drain —... Lavatory ,_ Water Close ,,,_ ..... Building sewer or trailer park sewer — Rain wa system per drain ', side building) _, Water heater an. vent I Additional medical gas inlets /outlets six or more — Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors ..� Rep or alteration of water p ng and /or water treating quipment 1 Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION - 206 - 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: i467 SCitt:TP City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration umber: Expiration Date: it ' I • Li Jr. tractor's bid price): $ Z � ono." Valuation of Plumbing work Valuation of Gas Piping work (co Scope of Work (please provide detai hLep /* I SAGS Fr - r Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets bet r)• fur Appi ()11 ur,. -noon - vcrn,n .Appticuuun.ana u��l,od o 2006 bh ewer: ailed and the quantity below: State Zip Page 5 of 6 Receipt No.: R08 -01717 Payee: GREG ANDERSON ACCOUNT ITEM LIST: Description doc: Receipt -06 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us Payment Check 8845 60.00 RECEIPT Parcel No.: 6364200010 Permit Number: M08 -037 Address: 2600 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 02/12/2008 Applicant: JOHNNY ROCKETS Issue Date: 05/02/2008 Initials: JEM Payment Date: 05/19/2008 02:38 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000.322.102.00.0 60.00 Total: $60.00 Payment Amount: $60.00 2597 05/19 9711 TOTAL 60.00 Printed: 05-19 -2008 Parcel No.: 6364200010 Permit Number: M08 -037 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/12/2008 Applicant: JOHNNY ROCKETS Issue Date: Receipt No.: R08 -01207 Initials: WER Payment Date: 04/16/2008 01:32 PM User ID: 1655 Balance: $0.00 Payee: WESTWOOD CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 144296 361.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000.322.102.00.0 361.00 Total: $361.00 Payment Amount: $361.00 1245 04/16 9711 TOTAL 2551.50 doc: Receiot -06 Printed: 04 -16 -2008 Receipt No.: R08 -00400 Payee: RS HERMAN ARCHITECTS, INC. TRANSACTION LIST: Type Method Description ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -037 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/12/2008 Applicant: JOHNNY ROCKETS Issue Date: Initials: JEM Payment Date: 02/12/2008 12:50 PM User ID: 1165 Balance: $368.50 Amount Payment Check 10378 82.75 Account Code Current Pmts 000/345.830 82.75 Total: $82.75 Payment Amount: $82.75 8475 02/12 9710 TOTAL 82.75 doc: Receiot -06 Printed: 02 -12 -2008 Doc: RECSETS-06 RECEIPT NO: R08 -00402 Initials: JEM Payment Date: 02/12/2008 User ID: 1165 Payee: MARCIA PEDDICORD SET ID: S000000959 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us M08 -037 7.50 PG08 -036 23.00 TOTAL: 30.50 SET RECEIPT Total Payment: 30.50 TRANSACTION LIST: Type Method Description Amount Payment Check 4882 30.50 TOTAL: 30.50 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES Account Code Current Pmts 000/345.830 TOTAL: 30.50 30.50 8473 02/12 9710 TOTAL 30.50 Projec Ty pe of Inspection: k-in,2,/ Address: 2.6e) / Tj {�df Date Called: Special Instructions: Date Wanted: _/ 70d°, ,/ a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 flW -t 37 PERMIT NO. (206)431 -3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: er— El $60.00 SPECTION FEE REQUIRED. Prior to inspection, fee must be paid 00 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: • COMMENTS: • \ . Ana J An7� — ok^ • • . , (kJ fin toi 14 i l ° r OFt Date Wanted: 72'2 - t r 544 09,, le‘ o k, — cr[ 14 9I Phone No: 1 ,...f Cj(j114- oh 12O'a r'�444% (? ?.01 7 Ggv T. Gv . c:.1 rAykt.y ;Al Ce../ • LAI,t( 4 f( ,firm+. :, Project: 14"Y &tic Type of Inspection: \ Address: • 2.69 pc _{ Date Called: Special Instructions: Date Wanted: 72'2 - t p� .mm.. Requester: t I ,� yt5 � 1c Phone No: 1‘908 077 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. Inspector: Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: Date: COMMENTS: R A N 5 , I r4,1fi /f /� `-4 to 1 -q'^ i1 Slt ✓ tio, . j / rj eeiSor Sli 4.f y7 4ptpy.2ksi 11 ^h j SitJ' 0,i- -H /extv4s 5/v-rs 2fr• Special Instructions: - Date Wanted: ? -2 I p.m. Requester: r (s + Sj +•c 140 / Phone No: Project: 99 `� �wy g9ett l� Type of Insp ction: i_.... A�Pl I ..A* 4 j / Address: Apo re I - M4 I Date Called: Special Instructions: - Date Wanted: ? -2 I p.m. Requester: r (s + Sj +•c 140 / Phone No: INSPECTION RECORD Retain a copy with permit IN CTION NO. CITY OF TUKWILA BUILDING DIVISIO 6300 Southcenter Blvd., #100, Tukwila, WA 98188 flo& PERMIT NO. N (6)43 • -3670 ❑ Approved per applicable codes. NI Corrections required prior to approval. • Inspector: Date: 0 • ❑ $60.00 RISPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: Project: �^� �,n�J�J�J�.vj C-A,t K :: o Inpecti �+ 1. Address: ll 7r., CA rc -t, att : Special Instructions: Date Wanted: " - In . Ot a.m. p.m. Requester: P hone No: .Ptc INSPECTION RECORD Retain a copy with permit INSPECTION NO. • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: Inspector I Date : 7.zo .6% Receipt No.: 'Date: Project � b o. 1t. g Type of Inspect . Arli J � Address: 2410 ea Date Called: Special Instructions: Date Wanted: , / /� l Requester: Phone No: � r V9' 779:1 INSPECTION RECORD Retain a copy with permit # O'037 INSPECTION NO. I PEE MIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 =36 (Approved per applicable codes. El Corrections required prior to 'approval. COMMENTS: Inspector: Receipt No.: at 4 cal ),' e4oger E $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Date: Date: /0/ Pro � � l°��"C!'7� Type,* Inspe Iona t €4/,' A_dress / /7 . Date Called: Special Instructions: Date Wanted: 442 G Z 7- . C' Requester: Ph I /7- ei`Td- 7c/ INSPECTION RECORD Retain a copy with permit /1 3 7 INSPE ON NO. ' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: ?/L 1 1 4514. C/ G1 4r.CS Z.. 1((a41,4 oS i2/ - $e j Se vCvkIr *9 e-Cgs. 41eire,5 - 2.600 FG ° 1 Date: 12.7/4 $60.0 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ..!'[, Proje Typ of Inspection: Address: , Z,e m4 Date Called: Special Instructions: Date Wanted: {.� ,— f7.. C--/(14? a.m. p.m. Requester: Phone No: A . INSPECTION RECORD • • i Retain a copy with permit INSPECTION NO. py p " I " PERMIT NO CITY OF TUKWILA BUILDING DIVISION I- YZ= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval COM M ENTS:)j i9I 4r rer) co it • e/Ia a 5 Date / c v $6 . REINSPECTION FEE REQUIRED. Prior to inspection, fee must be • pa at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: i Prole db /poiee�s Nit/ y Type of I pection: • /2tiv9 -/A1 Ads GO 4 / 7 Date Called: Special Instructions: Date Wante : / (a Q Requester: Phone - t'cG - / 77 - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. COMMENTS: n+ ref► ., --, s toe-LAPS nspector:. Date: n $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: /mg IA Corrections required prior to approval. �3 Project: / Type of Inspection: .. A,"5,4,,,, Date Called: Address: • Special Instructions: Date Wanted: G a.m. Requester: Phone No: /7 `g5 G T9n/ INSPECTION RECORD Retain a copy with permit / -41 PERMIT NO. INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: J7/4 nspector: r, - ri $60 0 - EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai ' . 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Project: :)kt t jt rock e Type of ection: - P ec.1, c..‹._ Q„ u Address: c.00 f S, C. M kLt_ Suite #: cc _ 0( Contact P rson: Special Instructions: Phone No.: Needs Shift Inspection: Y Sprinklers: Fire Alarm: Sr Hood & Duct: /(''' "- Monitor: —rd, 14-e Pre-Fire: Permits: iv Occupancy Type: INSPECTION NUMBER 444 Andover Park East, Tukwila, Wa. 98188 206 -575- L . pproved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT COMMENTS: ,ice. C ,,tiVrL - d Inspector: A_ 5 1 V Date: 7 /aV(1 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 � '(_} (A 0 %- h 7 PERMIT NUMBERS Corrections required prior to approval. T.F.D. Form F.P. 113 COMMENTS: 5 e o I � n Type ion: NI) T14 S N (p - ci 0 , ti ) (Pope+; cA,t)dc,k kond /ve.o re \ . L -� sue. . - v .4.c.. Special Instructions: jj g a Mot), 4,,,O4, e, I ► 5 v,J c,105 .g. .t (ov . Phone No.: 51 — b il-im) -- r Ayc `3 ;,j C..>(.. /r� Project: '�'UN�,f,,L t a 5 e o I � n Type ion: NI) T14 S Address: c.00 S . c . Suite #: c _0) . \ . L -� Conta Person: Special Instructions: Occupancy Type: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTMENT Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS 444 Andover Park East Tukwila Wa. 98188 206 -575- Corrections required prior to approval. Inspector: k Date: -7 /a )/65 Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 1R. imam _- GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION - July 21, 200 R s c JUL 252008 �, NrIMUNITY Mr. TiDi ENT Westwood Contractors 951 W7thSt Fort Worth, TX 76102 RE: Special Inspection Johnny Rockets Tukwila, WA Dear Mr. Benson, azan & ASSOCIATES, INC. KA No. 066 -08147 Permit No. M08 -037 In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors from. June 4 through June 11, 2008. Copies of our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC gw' e6e-7-Z17-- Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila Offices Serving The Western United States 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 08147 OFR Template = FIELD = ' a Z a n . & A S S O C I A T E S, I N c. REPORT NO.: 8147DFR060408 -gn DATE: 6-4-08 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION PROJECT #: 066-08147 PROJECT: Jonny Rockets LOCATION: #FC 1 South Center Mall KRAZAN PROJECT MANAGER: K E.G. CONTRACTOR: Westwood PERMIT NO: rn O 037 INSPECTOR: George Neill / John Maggard JURISDICTION: City of Tukwila WEATHER: Cloudy Temp: 55 F Structural Steel Arrived on site as requested by the contractor to perform Structural Steel inspection in conformance to project plans and specs. 1) Met with the contractor to verify inspection and review plans. 2) Performed visual inspection of Grease Duct welded connection for 14' section preassembled and located on floor. Inspection was performed per section 506.3.3.1 IBC mechanical code 2006 version. Revealed welding to be acceptable. To the best of my knowledge, the above WAS ® / WAS NOT 0 performed in accordance with the approved plans, specifications, and regulatory requireme* Superintendent/Representative: Technician George Neill Offices Serving the Western United tates Equipment/Asset Number(s): Form 1501 r.2 Effective Date: 12 -20-07 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. aa77 � zan &ASSOCIATES, INC. DATE: 6 -11 -08 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION PROJECT #. 068 -08147 PERMIT NO: ) o 5S - d3 / INSPECTOR: George Neill / Mike Thomas JURISDICTION: City of Tukwila PROJECT: Jonny Rockets LOCATION: #FC 1 South Center Mall KRAZAN PROJECT MANAGER: K.E.G. Structural Steel Arrived on site as requested by the contractor to perform Structural Steel inspection in conformance to project plans and specs. 1) Met with the contractor to verify inspection and review plans. 2) Performed visual inspection of Grease Duct welded connection for 14' section to kitchen hood. Inspection was performed per section 506.3.3.1 IBC mechanical code 2006 Revealed welding to be insufficient with pin holes in the welds visible. 3) Weld should be repaired and re- inspected upon completion for final acceptance. To the best of my knowledge, the above WAS ❑ /WAS NOT Superintendent/Representative: ■;1 CONTRACTOR: Westwood WEATHER: Cloudy Offices Serving the Western United States FIELD REPORT NO.: 8147DFR061108 -gn Temp: 50 F Equipment/Asset Number(s): performed in accordance with the approved p ans, specifications, and regulatory requiremeWilp Technician George Neill / Mike Thomas Form 1501 r.2 Effective Date: 12 -20 -07 The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. YORK® It's Time to Get Comfortable' SUBMITTAL DATA FOR: Approval ORDER NO.: PROJECT: 9 1 l Kr® .00KETS PURCHASER: DIAMOND CONSTRUCTION SUBMITTED BY: `YORK NORTHWEST FILE COPY 11YORK It lime to Get comfortable' -. REVIEWED FOR CODE COMPLIANCE PPRi VED MAY 1 5 2008 COi Of Tukwila BUILDING DIVISION REVISION NO.1 0'1 DATE: 04/30/2008 RECEIVED CITY OF TUKWII,A MAY ,O 5 2008 PERMIT CENTER Date 04/30/2008 Project Name JOHNNY ROCKETS Client / Purchaser DIAMOND CONSTRUCTION Order No Save the Logo you want here as Logo.bmp in ESP's Dwgs folder. Submittal Summary Page (Equipment only. Refer to Quotation page or Schedules for selected accessories.) QTY SCHEDULE NO MODEL NO. DESCRIPTION 1 El RD060S46 460 -3 -60 13+ SEER Latitude Heat Pump 1 MA2OD 460 -3 -60 Modular Air Handling Unit 1 MC61 D Full -cased Multi- position Add -on Coil NOTES: ESP XP RPM JuN 2007 Suhlect to chance without notice - Cheek local codes Its Time to Get Comfortable" ENGINEER'S REPORT Date 04 /30/20 Page 6 13+ SEER LATITUDE HEAT PUMP / MODULAR AIR HANDLING UNIT Order No Project Name JOHNNY ROCKETS Engineer Architect Submitted By YORK NORTHWEST Quantity: 1 Model No: E1 RD060S46 / MA20D / MC61 D O.D. Schedule No: RTU & I.D. Schedule No: COOLING PERFORMANCE Total Capacity 57.5 MBH Sensible Capacity 44.6 MBH Efficiency (at ARI) 13.00 SEER Power Input (w /o blower) 3.95 KW Elevation levation 0 Ft Leaving DB Temp 59.6 F Leaving WB Temp 58.1 F Ambient DB Temp 85.0 F Entering DB Temp 80.0 F Entering WB Temp 67.0 F HEATING PERFORMANCE Entering Air Temp. 60.0 F Leaving Air Temp. 75.0 F Air Temp. Rise 15.0 F u Electric Heat Capacity 32.8 MBH Power Input 9.6 KW • Gas Heat Gas Fired Input N/A MBH Gas Fired Output N/A MBH ri Heat Pump Capacity: 47F 57.0 MBH 17F 34.4 MBH COP: 47F 3.66 17F 3.66 HSPF: 8.0 SUPPLY AIR BLOWER PERFORMANCE Total Supply Air 2027 CFM Outside Air 0 CFM External Static Pressure 0.56 IWG Return Air Opening(s) 1 Side, 1 Bottom Blower Speed HI Motor Rating 1 HP ELECTRICAL DATA Outdoor U Indoor Unit Power Supply 460 -3 -60 460 -3-60 Min. Circuit Ampacity 11.2 Amps 19.1 Amps Max. Overcurrent Protection 15 Amps 25 Amps OUTDOOR UNIT CLEARANCES Front 10 in Back 24 in Bottom 0 in Top 60 in Left Side 10 in Right Side 10 in INDOOR UNIT CLEARANCES Top in Left Side 1 in Front 24 in Right Side 1 in Rear 1 in Flue in Bottom in B-vent Clearances (Furnaces): Top in Left Side 1 in Front in Right Side in Rear 1 in Flue in Bottom in ' Special floor base or A/C coil required for use on combustible floor. *" Cabinet clearance is 0 ", vent dearance is required. APPROXIMATE DIMENSIONS & WEIGHT Outdoor Unit: Height 38. in Width 43. in Depth 32. in Total Weight 294 Lbs Blower Unit: Height 25. in Width 24. in Depth 22. in Total Weight 156 Lbs Furnace: Height 0.00in Width 0.00 in Depth 0.00 in Total Weight 0.0 Lbs Indoor Coil: Height 36. in Width 24. in Depth 22. in Total Weight 98.0 Lbs g Engineer's Notes: wlmart rge notice - check local c COOLING PERFORMANCE Total Capacity 57.5 MBH Sensible Capacity 44.6 MBH Efficiency (at ARI) 13.00 SEER Thermal expansion valve required for SEER rating. Outdoor DB Temp 85.0 F Power Input (w /o blower) 3.95 KW Elevation 0 Ft Sound Power 79 Dbels HEATING PERFORMANCE Capacity at 47 Deg. F 57.0 MBH Capacity at 17 Deg. F 34.4 MBH COP at 47 Deg. F 3.66 COP at 17 Deg. F 3.66 ELECTRICAL DATA Power Supply 460 -3 -60 Minimum Circuit Ampacity 11.2 Amps Max. Overcurrent Protection 15 Amps DIMENSIONS & WEIGHT Height 38.0 in Width 43.0 in Depth 32.0 in Total Weight (incl factory options) 294 Lbs CLEARANCES Front 10 in Left Side 10 in Back 24 in Bottom 0 in Right Side 10 in Top 60 in YORK Its Time to Get Comfortable" LATITUDE SPLIT - SYSTEM HEAT PUMPS Date 04/30/20 Page 2 Order No Project Name JOHNNY ROCKETS Architect Engineer Purchaser DIAMOND CONSTRUCTION Submitted By YORK NORTHWEST QUANTITY: 1 UNITS DESIGNATION: Schedule No: Model No: El RD060S46 FIELD INSTALLED ACCESSORIES ❑ Hard Start Kit ❑ Low Ambient Kit ❑ Refrigerant Safety Kit ❑ Solenoid Valve El 5- minute Time Delay ❑ Fossil Fuel Relay ❑ Hail Guard Kit ❑ Compressor Blanket Kit ❑ Outoor Thermostat ❑ Low Temperature Cutout ❑ Rubber Isolater Grommets ❑ Indoor Thermostat Notes: ISO 9001 CERTIFIED GENERAL FEATURES - U.L and C.U.L. listed - approved for outdoor application. - ARI Certified. - Quality copper tube/hardened aluminum fin coil. - Coil is protected by a polymer mesh and a PVC coated steel coil guard. - Standard liquid line filter -drier. - Internally protected compressor with high pressure relief valve and temperature sensor. - Low operating sound levels with cushioned compressor mounts - Long life permanently lubricated motor bearings. - Time/temperature demand defrost control with ainti-short cycle timer. - R -22 total system operating charge (thru 15 ft. of lines). - Fully exposed sweat refrigerant connections with re- usable service valves. - Propeller type fan with top air discharge and molex plug connector. - Durable construction. - Pre - painted galvanized steel cabinet with Desert Sand matte finish. - Factory wired line and low- voltage controls. - Factory tested. - Easy access to electrical and compressor compartments. - 5 -year limited parts warranty on 1 -phase models. - 5 -year limited compressor warranty. ESP XP RPDF July 2007 Subject to change without notice - Check local codes COOLING PERFORMANCE Total Capacity 57.5 MBH Sensible Capacity 44.6 MBH Total Supply Air 2027 CFM Entering DB Temp 80.0 F Entering WB Temp 67.0 F Leaving DB Temp 59.6 F Leaving WB Temp 58.1 F Elevation 0 Ft HEATING PERFORMANCE Electric Heat Capacity 32.8 MB Power Input 9.6 KW SUPPLY AIR BLOWER PERFORMANCE Total Supply Air 2027 CFM Outside Air 0 CFM External Static Pressure 0.56 IWG Blower Speed HI Motor Rating 1 HP ELECTRICAL DATA Power Supply 460 -3 -60 Minimum Circuit Ampacity 19.1 Amps Max. Overcurrent Protection 25 Amps DIMENSIONS & WEIGHT Air Handler Only Height 25.0 in Width 24.5 in Depth 22.00 in Total Weight (incl factory options) 156 Lbs CLEARANCES Front 24 in Left Side 1 in Rear 1 in Right Side 1 in Y om® It's Time to Get Comfortable" MODULAR AIR HANDLING UNIT Date 04/30/20 Page 3 Order No Project Name JOHNNY ROCKETS Architect Engineer Purchaser DIAMOND CONSTRUCTION Submitted By YORK NORTHWEST QUANTITY: 1 UNITS DESIGNATION:schedule No: Model No: MA20D FACTORY INSTALLED OPTIONS ❑ Thermal Expansion Valve GENERAL FEATURES • Upflow, downflow or horizontal applications Durable pre - painted steel cabinet - Singe and three phase electric heaters with nickel- chromium elements • Circuit breakers standard on 208/230 volt, single phase heaters 13kW and larger - Over - temperature limit switches protect from air flow loss • One - minute blower off delay standard (MA) • One inch foil face fiberglass insulation on all models • Approved for "0" inch clearance without electric heat • Approved for "1" inch clearance with electric heat installed Direct drive, multi -speed blower motor (MA) • Varaible speed, ECM motor (MV) - automatically adjusts blower speed to boost efficiency - ramps up to full speed and ramps off for quiet operation - allows different CFM settings for heating and cooling - automatically operates at CFM selected, regardless of ESP • MC multi - position coils with: - bolt-on thermal expansion Valve and sensing bulb mounted inside cased coil cabinet for flexibility to convert any coil to R22 or R410a (Must be field supplied for all "Flex- coils ".) - MicroBlueTM Hydrophilic coated fins enhance removal of condensate and reduces growth of germ causing microbes - staggered rows of copper tubes, mechanically expanded into aluminum fins provide optimum heat transfer - 3/4 inch foil face insulation 5 -year limited parts warranty on 1 -phase models including heating elements • 1 -year limited parts warranty on 3 -phase models including heating elements ESP XP RPDF July 2007 Subject to change without notice - Check local codes COOLING PERFORMANCE Total Capacity Sensible Capacity Total Supply Air Entering DB Temp Entering WB Temp Leaving DB Temp Leaving WB Temp Elevation 57.5 MBH 44.6 MBH 2027 CFM 80.0 F 67.0 F 59.6 F 58.1 F 0 Ft DIMENSIONS & WEIGHT Height 36.0 in Width 24.5 in Depth 22.00 in Weight 98.0 Lbs . . • YORK It's Time to Get Comfortable SPLIT-SYSTEM ADD -ON COOLS Date 04/30/20 Page 5 Order No Project NameJOHNNY ROCKETS Architect Engineer Purchaser DIAMOND CONSTRUCTION Submitted By YORK NORTHWEST QUANTITY: 1 UNITS DESIGNATION:schedule No Model No: MC61 D FIELD INSTALLED ACCESSORIES ❑ Thermal Expansion Valve ❑ Coil Casing without Coil Notes: GENERAL FEATURES - Bolt -on Thermal Expansion Valve and sensing bulb mounted inside cased coil cabinet for flexibility to convert any coil to R22 or R410a (Must be field supplied for all "Flex- coils ".) - MicroBlueTM Hydrophilic coated fins enhance removal of condensate and reduces growth of germ causing microbes Staggered rows of copper tubes, mechanically expanded into aluminum fins provide optimum heat transfer - Thermally insulated cabinet to prevent sweating - Pre - painted steel cabinet - All coils are factory leak- tested, dehydrated, sealed and shipped with a holding charge. ESP XP RPDF July 2007 Subject to change without notice - Check local codes p ay ORK® It's Time to Get Comfortable" MODULAR AIR HANDLING UNIT Date 04/30/20 Page 4 Order No Schedule No.: Model No.:MA2OD Coil Model No: MC61 D Notes: FIELD INSTALLED ACCESSORIES ❑ UPFLOW SUSPENSION KIT ❑ BOTTOM FILTER RACK ❑ HORIZONTAL DRAIN PAN KIT ❑ HUMIDISTAT ❑ BOLT ON TXV KIT ® ELECTRIC HEATER 4HK06501046 ❑ COMBUSTIBLE FLOOR BASE ❑ COIL CASING WITHOUT COIL ESP XP RPDF July 2007 Subject to change without notice - Check local codes ANF & ASSOCIATES April 7. 2008 Westfield Design & Construction 633 South Center Trailer #3 Seattle, CA 98188 Attn: Bryan Low, Tenant Coordinator RE: HVAC Equipments on Level 3 South Center, Tukwila, WA Dear Bryan: Sincerely yours, ANF & Associates Michael H. Wang, P.E. Associate FILE C %} 7 imam tie fie a -» I Permit Mori Consulting SSruu t� F,ngineers We have completed our review of the level 3 floor framings at the designated HVAC equipment areas based on the following criteria: 1) Maximum single equipment weight of 1,500 lbs with a plan area of 6 square feet minimum. 2) There is no floor opening required under the equipment. 3) Minimum clearance between equipments is 3' -0" on 4 sides typical. Our review shows that the level 3 floor framings at the designated 1-IVAC equipment areas can safely support the HVAC equipments if the criteria as mentioned above are met. Level 3 floor framings under the equipments which do not meet the criteria as mentioned above shall be reviewed and reinforced as required by a professional engineer registered in the state of Washington. Please call us should you have any questions regarding the above. AIW''D} rh E Letter to Westfield D & C re HVAC level Sat South Center tfall dated 4 -7 -2005 -'"REVIEWED CE CODE COMPLIA LIWPRO MAY _ 1 2008 11 �. tr', i1a 5 CORRECTION RECEIVED CITY OF TUKWILA 9420 Telster Ave.. Suite 118 • Flair Commerce Center • El Morita, CA 91731 • Tel: (626) 4411 -8182 • Fax (626) 448 -8092 APR 2 3 2008 PERMIT CENTER (626) 448-8182 ANF &ASSOCIATES Fax: (626) 44134092 S C i L TH C.C. M rerL- Swan: sal16811(apsotelLnot Consulting Structural Engineers Tt-iLft tAJA 9420 Telstar Avenue, Suits 118, In Monte, CA 91731 1 MECH. CURB PER MECHANICAL DRAWINGS CONC. TOPPING OVER METAL DECK \ SECTION A-A C8x11.5 TYP. - HILTI --5/8"0 KWIK EXP. BOLT x4' EMBED. (ICBO# 4780) \ EDGE OF NEW OPEN'G pL.1/4x8 PL.1/4x8 NOTE (E)STL. B DO NOT OVERCUT OF CONCRETE FLOOR OPEN'G CORE DRILL 4"0 OPEN'G 0 CORNERS & THEN SAWCUT THE REST OF OPEN'G. A 6'-O" MAX. C10x15.3 -1 OR W12x14 37F6r; 6 PLAN r N. .AN/i " RETURN 2;142" /3116 1, J \ \sr 3/16 i> SECTION B-B FLOOR BEAMS SEE PLAN r TYP. CONC. FLOOR OPENING DETAIL SK1-031008 Joe No. 2■51e, BY £1 omt 3 -,0 - Or N \ � r - . __ - - - • L. 110.: (626) 448 -8182 AID' & ASSOCIATES ( Consulting wA . 942 011514tAv ___,_site 118,E1 Monte, CA91731 Joe No. t "5 b T sy max 3 -/' Sm. ,OF METAL DECK W /--- -, SINGLE OPENING (N) L3x3x1 /4 W/5/8 ".0 KWIK BOLT II -TO BETTOM OF FLUTE ©12 "O.C. WITH 4 1/2" EMBED GROUP OF OPEN'GS NOTES; 1. DO NOT CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPENINGS NOT LARGER THAN 8" DIAMETER OR 8" SQUARE REQUIRE NO ANGLES. 3. CONC. OPENINGS OR GROUP OF OPENING EXCEEDING 16" OR CUTTING 2 BOTTOM FLUTES REQUIRE SECONDARY BEAM REINFORCEMENT AS PER DETAIL SK 1- 031008 NP. FETAL DECK ROOF FLOOR OPEN G W/ CONC. TOPPING SK2- 031008 .... ....,.. . ....... i I \ � / / fi t - 1 * - j 1 -4 2 2' - *' t r 2°'" 1 1 r 110.: (626) 448 -8182 AID' & ASSOCIATES ( Consulting wA . 942 011514tAv ___,_site 118,E1 Monte, CA91731 Joe No. t "5 b T sy max 3 -/' Sm. ,OF METAL DECK W /--- -, SINGLE OPENING (N) L3x3x1 /4 W/5/8 ".0 KWIK BOLT II -TO BETTOM OF FLUTE ©12 "O.C. WITH 4 1/2" EMBED GROUP OF OPEN'GS NOTES; 1. DO NOT CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPENINGS NOT LARGER THAN 8" DIAMETER OR 8" SQUARE REQUIRE NO ANGLES. 3. CONC. OPENINGS OR GROUP OF OPENING EXCEEDING 16" OR CUTTING 2 BOTTOM FLUTES REQUIRE SECONDARY BEAM REINFORCEMENT AS PER DETAIL SK 1- 031008 NP. FETAL DECK ROOF FLOOR OPEN G W/ CONC. TOPPING SK2- 031008 February 26, 2008 Richard Herman 6009 Melrose Avenue Los Angeles, CA 90038 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -037 Johnny Rockets — 2600 Southcenter Mall, Suite FC -1 Dear Mr. Herman, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Brenda Holt Permit Coordinator encl xc: File No. M08 -037 • Department of Community Development 140*- P:\Pennit Center \Correction Letters \ 2008%408 -037 Correction Lb- #1.DOC wer • Jim Haggerton, Mayor Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Building Division Review Memo Date: February 22, 2008 Project Name: Johnny Rockets Permit #: M08 -037 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner l il The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Cover sheet mechanical note #29 and general notes #7 references out dated codes and jurisdictions located out of state. Please revise all relative plan notes and make necessary changes to show where all plan specifications and code notes reference the current 2006 International Mechanical Codes and where mechanical equipment shall comply with 2006 Washington State Energy Codes. 2. The combined load for the new mechanical equipment on the roof indicates exceeding 1800 pounds. New mechanical equipment to be installed on the roof exceeding 400 pounds shall require an engineer's analysis for the roof structure with calculations to show the roof structural members are sufficient for the combined loads imposed by all the mechanical equipment. Provide details with the engineer's calculations. All engineer's documents shall be original wet stamped and signed by the engineer. 3. Please identify what method shall be used where drainage of grease from the roof exhaust fan shall be captured in an approved grease reservoir. (IMC 506.5.2) 4. SEER specified on mechanical AC unit references 12 SEER. Update the reference to meet the current energy code requirements. (2006 WSEC Table 14 -1A) 5. Type I hoods with make up air system and exhaust fan shall be activated automatically whenever cooking operations occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. Please provide that note on the plans as it is specified in the mechanical code. (2006 IMC 502.2.1.1 & 508.1) 6. Please provide two complete sets of mechanical plans with all changes made. Plans shall be wet stamped and signed by the engineer preparing the plan documents. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: M08 -037 DATE: 05 -06 -08 PROJECT NAME: JOHNNY ROCKETS SITE ADDRESS: 2600 SOUTHCENTER MAIL, FC -1 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: s fi ) Build g I'► Sion Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 171 Incomplete Comments: • PERMIT COORD COPY O PLAN REVIEW/ROUTING SLIP TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: 61I Fire Prevention Structural n Planning Division ❑ Permit Coordinator Not Applicable ❑ No further Review Required DATE: DATE: DUE DATE: 05-08-08 Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 06-05-08 Approved Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: D ivision Public Works Complete Comments: Documents/routing slip.doc 2 -28 -02 •PERINIT COORD COPY 0 PLAN REVIEW /ROUTSfdG SUP ACTIVITY NUMBER: M08 - 037 DATE: 04 -23 -08 PROJECT NAME: JOHNNY ROCKETS SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -1 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n n Planning Division Permit Coordinator DUE DATE: 04 -24-08 Not Applicable n Permit Center Use Only i INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW El Staff Initials: No further Review Required DATE: Not Approved (attach comments) DATE: n n DUE DATE: 05-22-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -037 PROJECT NAME: JOHNNY ROCKETS SITE ADDRESS: 2600 SOUTHCENTER MALL, FC -1 X Original Plan Submittal Response to Correction Letter # DATE: 02 -12 -08 Response to Incomplete Letter # Revision # After Permit Issued DE ARTIsjENTS: or g Division b Works HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP n Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: Documents routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Fire Prevention gl Planning Division ❑ Permit Coordinator No further Review Required DATE: DATE: n n DUE DATE: 02-14-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: DUE DATE: 03 -13 -08 Not Approved (attach comments) Fi Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Er Fire ❑ Ping ❑ PW ❑ Staff Initials: l!A� REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS 1 OCI0 Sk (Th Oi I q 1M Summary of Revision: S ummary of Revision: C.,[0)4 f-yLoAA ,- `lam ig IA Kg 1V Splay y4(fl Received by: a gE / ,, i ), & REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: REVISION NO. DATE. RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S ummary of Revision: Received by: PROJECT NAME: 3OIN t-kk( 0001( PERMIT NO: 0 /Vi 'OW SITE ADDRESS: 21Q()D Sri AAA'U- TZ■ ORIGINAL ISSUE DATE: (G' ldi REVISION LOG (please print) (please print) (please print) (please print) (please print) Date: S - o e Created: 8 -13 -2004 Revised: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: hap : / /www.ci.tukwila.wa.us Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. oe- Plan ChecWPermit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # j after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: john f7�1 fCL7G Project Address: 240c5r, / �r���iGP�74 / , ! /, / c c ht. Contact Person: /e / -/-€ Phone Number: S S -79 7- 3 YS7 Summary of Revision: 1M c�ka t.nn - 4 Sp L-4-- S tefrpt. RECEIVED CITY OF TTUKWI[ t MAY .0.5 ZUU PERMIT CENT'4 Sheet Number(s): A14/ "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on J - 6 -c lapplicationsVorms- applications on linelrevision submittal Date: Project Name: Project Address: Contact Person: - S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http : //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑L - Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner —� h h n // J Z(Qo R Summary of Revision: 1 /— � - -ey �� 7� ee, c„, - Phone Number: Received at the City of Tukwila Permit Center by: Entered in Permits Plus on I 'Zb 14 `applicationslforms- applications on line\revis:on submittal Created: 8 -13 -2004 Sheet Number(s): /77 D . 0 MD. Z 1 M.O. 3 3 MD. "Cloud" or highlight all areas of revision Including date of revision Steven M. Mullet, Mayor Steve Lancaster, Director Crry or ru KwitA APR 2 3 2008 PERMIT CENTEh 424 214 — c,15� License Information License WESTWCI088BF Licensee Name WESTWOOD CONTRACTORS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601011419 Ind. Ins. Account Id Business Type CORPORATION Address 1 951 W 7TH STREET Address 2 ATTENTION: LILY SEGURA City FORT WORTH County OUT OF STATE State TX Zip 76102 Phone 8178773800 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/6/1992 Expiration Date 9/11/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date BENDA, ROBERT D 01/01/1980 06/11/2002 CHASE, DAVID E 01/01/1980 06/11/2002 BENDA, JOAN M 01/01/1980 06/11/2002 Look Up a Contractor, Electrn or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 0 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date TRAVELERS CAS & Until Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= WESTWCI088BF 05/02/2008 NORTH HVAC PLAN - SPACE FC -1 GREASE EXHAUST AIR DUCT SHALL SLOPE A MINIMUM 1 /4" PER FOOT OF HORIZONTAL DUCT (2% SLOPE). PROVIDE CLEANOUT ACCESS DOORS IN BOTH RATED ENCLOSURE AND WELDED STEEL OR STAINLESS STEEL GREASE DUCT AT VERTICAL FACE NEAR AT ALL LOW POINTS (TYP.). ALL GREASE EXHAUST DUCT SHALL BE 16 GAUGE BLACK STEEL CONCTRUCTION. GREASE EXHAUST DUCTS SHALL BE AIR AND LIQUID TIGHT WELDED CONSTRUCTION. INTERLOCK MAKE -UP AIR UNIT WITH KITCHEN EXHAUST FAN TO OPERATE THE UNITS AT THE SAME TIME. CONTRACTOR SHALL PROVIDE SPECIAL INSPECTION AND PERFORMANCE TESTING PER LOCAL CITY REQUIREMENTS AND IMC SECTIONS 507.16, 507.16.1, 507.13 AND 508.1. ALL THE COMBUSTIBLE MATERIALS SHALL BE MINIMUM 18" AWAY FROM ALL THE GREASE DUCTWORKS. PROVIDE INTERNAL DUCT LINING IN LIEU OF FLEXIBLE DUCTWORK AS REQUIRED TO MAINTAIN THE CLEARANCE. PROVIDE FIRE RATED WRAP FOR THE ENTIRE EXHAUST DUCT SYSTEM. 7. SEE KITCHEN DRAWINGS FOR INSTALLATION DETAILS OF THE EXHAUST AND MAKE -UP FANS. KITCHEN VENTILATION NOTES: 600 (TYP. 2 E34tA;PMENT �f4b env QcoF Rt4-i5- c-s- KITCHEN EXHAUST DUCT SHALL BE PROVIDED W/ CODE APPROVED FIRE RATED WRAP. SLOPE DUCT TOWARD THE HOOD CONTRACTOR TO COORDINATE THE LOCATION OF THE HOOD W/ KITCHEN CONSULTANT EXISTING MECHANICAL ROOM ON THE ROOF. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL MECHANICAL EQUIPMENT INSIDE THE ROOM AND RELOCATE THE THE EQUIPMENT AS REQUIRED. MAINTAIN A MIN. OF 10' CLEARANCE FROM EXHAUST DISCHARGE AIR TO OUTSIDE AIR INTAKE TO THE UNITS. COORDINATE LOCATION OF ROOF OPENINGS W/ ARCH, LANDLORD AND STRUCTURAL ENGINEER. MECHANICAL SPECIFIC NOTES SCALE : 1/4 = By Date: FC1 MECH. SEE (] PARTIAL HVAC ROOF PLAN REQUIRED PERMIT mechanic . ctric I Umbing tirGas Piping BVI City Tukwila VISI pN SPLIT SYSTEM SCHEDULE MARK MAKE MODEL AIR OA AMBIENT EXT. DX COOLING COIL HEAT PUMP STRIP HEAT ELECTRICAL SEER APPROX. REMARKS FLOW FLOW OAT S.F. EAT TOTAL SENSIBLE Capacity COP Capacity Pwr input VOLTS 1 0 / HZ MOTOR MCA MOCP WEIGHT (CFM) (CFM) (F) (1N.W.C.) (FDB /WB) (BTU /HR) (BTU /HR) MBH MBH KW HP (AMPS) (AMPS) (LBS) AH -1 York MA2ODN4 2027 300 85 0.56 32.8 9.6 460 / 3 / 60 1 19.1 25 Blower & coil 254 CU-1 York E1RD060S46 85 80 / 67 57.5 44.6 57@,47F3.66 @ 47 F 460/3 / 60 11.2 15 13 294 FILE COPY Permit No. eat 0 Pear~ review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted or ordinance. Receipt of approved Fiel o y gn4 r eons is a+d rledged: City of Tukwila BUILDING DIVISION " 1 2.0 x Iz 1K REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. BEVSI FO C() Pl IA, P WOVE MAY 1 5 2006 RECEIVED crrr @MA`f 0 5 Nat z 0 vs 4 W (1) u) ICI n ca ISSUED APPROVAL ISSUED FOR PL N CHECK ISSUED FOR =MING ISSUED FOR • PERM' ISSUED FOR ISSUED FOR: DESIGNED BY: DRAW BY: cIIECD BY: REVIEWED BY: IMIE: 12.26.2007 IIOS NUMBER: 07935 FILE #: M1.1 SHEET TITLE: HVAC FLOOR PLAN SCALE AS NOTED SHEET NUMBER: M1.1 NOISIA3a LANDLORD & BUILDING DEPT. REVISIONS I 2600 SOUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON ISSUED FOR PERMIT ;1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 1 fi. 17. 18. 19. 20. 21. 22. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL CEILING DIFFUSERS, LINEAR DIFFUSERS, RETURN GRILLES AND EQUIPMENT ACCESS PANELS. COORDINATE ANY DISCREPANCIES BETWEEN DRAWINGS BEFORE PROCEEDING IN NE FIELD. CONTRACTOR SHALL LAYOUT THE DRAWING PER CONTRACT DOCUMENT AS MUCH AS POSSIBLE. ANY LARGE DEVIATION IN LAYOUT SHALL BE APPROVED BY THE ARCHITECT PRIOR TO CONSTRUCTION. CONTRACTOR SHALL SUBMIT ONE (1) SET OF VELLUM AS- BUILTS AND TWO (2) SETS OF BLUE LINE AS- BUILTS TO THE BUILDING OWNER AND ONE SET OF VELLUMS AND ELECTRONIC FILES TO THE ENGINEER. ALL EQUIPMENT & MATERIALS SHALL MATCH BASE BUILDING SPECIFICATIONS AND INSTALLATIONS. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. INSTALL CFSD & FIRE DAMPER ON ALL DUCTS PENETRATING FIRE RATED ENCLOSURES, PARTITIONS, AND TUNNEL CEILINGS. PROVIDE ACCESS PANELS FOR ALL CFSD & FD ABOVE INACCESSIBLE CEILINGS. PROVIDE SMOKE DETECTOR DEVICE IN DUCTWORK CONNECTED TO CFSD. INSTALL DUCT S.D. PER MANUFACTURER'S APPROVED LISTING & INSTALLATION INSTRUC11OINS. ALL FIRE OR COMBINATION FIRE SMOKE DAMPERS ARE NEW UNLESS OTHERWISE NOTED. EXISTING FIRE OR COMBINATION FIRE SMOKE DAMPERS THAT ARE NOT TO BE UTILIZED SHALL BE REMOVED. ALL DUCTWORK SHALL BE GALVANIZED STEEL. ALL DUCTWORK AND LINING SHALL BE CONSTRUCTED AND INSTALLED PER SMACNA "HVAC METAL DUCT CONSTRUCTION STANDARDS" LATEST EDITION. ALL 45- DEGREE LEADING EDGES, CONICAL TAP -IN FITTINGS, EXTRACTORS, TURNING VANES (WHERE APPROPIATE), PROPERLY DESIGNED PLENUMS, AND OTHER SHEET METAL FITTING AND AIR FLOW DEVICES SHALL BE INSTALLED PER THESE SMACNA GUIDELINES. WHERE CONNECTING FLEXIBLE DUCTWORK TO CEILING DIFFUSERS AND CEILING REGISTERS, SIZE OF FLEXIBLE & BRANCH DUCT SHALL BE SAME SIZE AS NECK OF CEILING DIFFUSER OR CEILING REGISTER. MAXIMUM LENGTH TO BE 7 -0 LONG. ALL SUPPLY, RETURN, AND EXHAUST DIFFUSERS & GRILLES (NOT INCLUDING TOILET EXHAUST) SHALL HAVE A MINIMUM OF (1) 6' -O" LONG ACOUSTICAL DUCT. EXISTING DUCTWORK ACTUAL LENGTH AND SIZE MAY BE DIFFERENT THAN WHAT IS INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND PROVIDE ALL OFFSETS AND TRANSITIONS, AS REQUIRE FOR A COMPLETE INSTALLATION. PROVIDE A VOLUME DAMPER IN EACH BRANCH DUCT TO OUTLET WHETHER SHOWN ON DRAWING OR NOT. DAMPERS SHALL BE AS FAR AWAY FROM DIFFUSER AS POSSIBLE, PREFERABLY AT THE BRANCH TAKE -OFF. CONTRACTOR SHALL TAG VOLUME DAMPERS WITH RED OR YELLOW RIBBONS. A MINIMUM OF 30" WIDE BY 30" HIGH CLEAR WORKING SPACE SHALL BE PROVIDED IN FRONT OF THE ACCESS PANELS TO ALL A/C UNIT'S COMPRESSOR, BLOWER ASSEMBLY, & THE AIR FILTER. A MINIMUM OF 36" CLEAR WORKING SPACE, NOT LESS THAN 30" WIDE, SHALL BE MAINTAINED IN FRONT OF ALL SWITCHES, OVERCURRENT DEVICES AND ELECTRIC CONTROL COMPONENTS. INTERLOCK ALL MOVING AIR EQUIPMENT SUCH AS FANS WITH THE FIRE LIFE SAFETY SYSTEM ALL A/C UNITS & EXHAUST FANS SHALL SHUT OFF WITH THE AIR HANDLING UNIT UPON DETECTION OF SMOKE BY THE FLS SYSTEM. CONTRACTOR SHALL PROVIDE POWER, ELECTRICAL WIRING, CONDUITS, FOR ALL NEW, EXISTING AND RELOCATED AC UNITS AND SMOKE DETECTORS INTERLOCKS. ALL PIPING AND ASSOCIATED FITTINGS AND VALVES SHALL BE OF SIMILAR MATERIAL PER CODE, UNLESS APPROVED OTHERWISE. PROVIDE DIELECTRIC COUPLING BETWEEN JOINTS OF DISSIMILAR MATERIALS. ALL PIPING SHALL BE LABEL EVERY 10 FT. MFR SHALL BE MSI OR APPROVED EQUAL. ALL PIPING& DUCT PENETRATION THROUGH RATED CONSTRUCTION SHALL BE PROPER FIRE STOP WITH UL -LIST FIRE STOPPING PRODUCTS. CONSULT WITH UL FIRE RESISTANCE DIRECTORY FOR ADDITIONAL REQUIREMENTS. ALL PIPING & DUCTS PENETRATION THROUGH NON -RATED CONSTRUCTION SHALL BE PROPERLY AND GENEROUSLY CAULKED WITH SOUND RESISTANT MATERIAL SUCH AS SILICONE. USE ACOUSTICAL SEALANT AROUND DUCTS INSTALLED INTO ACOUSTICAL PARTITIONS. CONTRACTOR TO PROVIDE TRANSFER DUCTS, SIZED PER OUR DETAIL, FOR ALL ROOMS ENCLOSED BY FULL HEIGHT WALLS ON ALL SIDES. ALL EXISTING INSULATION ON THE MAIN DUCTWORK THAT OUR LOOSE OR DAMAGED SHALL BE REPLACED BY THE CONTRACTOR. CONTRACTOR SHALL PATCH AND REPAIR ANY AIR LEAKAGES AND HOLES ON EXISTING DUCTWORK. V SHEET NO. SHEET TITLE AND NOTES PLAN S CA LE REVIEWED BY: - DATE: 1 2.26.2007 M0.1 SYMBOLS, ABBREVIATIONS M 0.2 MECHANICAL SCHEDULE M 0.3 MECHANICAL DETAILS M 0.4 MECHANICAL DETAILS M1.1 HVAC FLOOR AND ROOF N ON E N ON N ON N ON E 1 /4 " =1' - 0" SHEET INDEX 1 / R� ® � � CODE ®Ni P9 APPROV , . S SINGLE LINE DUCTWORK (NEW) SINGLE LINE DUCTWORK (EXISTING) SINGLE LINE DUCTWORK (EXISTING TO BE DEMOUSHED) DOUBLE LINE DUCTWORK (NEW) FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX L0'9Z'Z l L0'0171 31ba f DOUBLE LINE DUCTWORK (EXISTING) DOUBLE LINE DUCTWORK (EXISTING TO BE DEMOLISHED) l=:' SEPARATE PERMIT REQUIRED FOR: Mechanical � pmhing GasP�png City of Tukwila _BUILDING DIVISION y _ 1 2Qp8 TO �, ; / 1 �`� • il� `:i ., ®f on Y�. ®� - : ® . . L , f N � roval is s tc>' e rlrota a � constr�acfion � � dO�S � of any ado:: + oroi Re m , F @I C �'�� �� ` •: �� ,' �� - p2 #J C� yO I F TUti'l a B U I LDIN G DIVI RE1/IStONS � $hati be made fo fhe scope w° Wifh oPriarapproyal o f Tukwila Building pivi wiU require a n p lan suhm itfat DUCTWORK W ITH ACOUSTIC L INING } AUTOMATIC 0 SD SMOKE DAMPER 0 CFSD COMBINATION FIRE AND SMOKE DAMPER UP PD p review Approval of o the violafion aPl�y� Date: Noch °f N O't� Revi � d mayinclude ad d � o naipl anrevi� y f ees. RISE IN DUCTWORK (IN DIRECTION OF AIR FLOW) DN Mo Ajkoq DROP IN DUCTWORK (IN DIRECTION OF AIR FLOW) 0 100 CEILING SUPPLY, TYPE 1, THROW PATTERN 4 -WAY, 100 CFM CR -1 "` 100 CEILING RETURN, TYPE 1, 100 CFM CEILING EXHAUST, TYPE 1, 100 CFM X 1 I � SD SMOKE DETECTOR Q � WALL SWITCH CD POINT OF CONNECTION POINT OF DISCONNECTION 0 THERMOSTAT O EXISTING THERMOSTAT TO REMAIN • • • EFFECTIVE JULY 1, 2007 THE CITY OF TUKWILA WILL BE UNDER THE 2006 INTERNATIONAL CODES AND ALL PERMIT SUBMITTALS NEED TO BE IN CONFORMANCE WITH THIS EDITION. IT IS THE TENANT'S /TENANT ARCHITECTS RESPONSIBILITY TO VERIFY AND CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. SUBSEQUENT PLANS WILL BE REVIEWED UNDER THE THEN CURRENT CODES AND ORDINANCES. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REGULATIONS. • • • • • TENANT'S CONTRACTOR IS TO VERIFY LOCATION; GET APPROVAL AND REQUIREMENTS FOR ALL CORING LOCATIONS ON CONCRETE FLOORING WITH WESTFIELD'S ON -SITE TENANT COORDINATOR PRIOR TO PROCEEDING WITH WORK. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, MECHANICAL AND ELECTRICAL DEVICES PENETRATING FLOOR SHALL BE FIRE RATED. ALL ROOF PENETRATIONS MUST BE APPROVED BY WESTFIELD'S ON -SITE TENANT COORDINATORS. ALL ROOF PENETRATIONS SHALL BE MADE BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT TENANT'S EXPENSE. ALL FINAL WEATHERPROOFING SHALL BE DONE BY WESTFIELD- APPROVED WATERPROOFING CONSULTANT PER LANDLORD'S SPECIFICATIONS AT TENANT'S EXPENSE. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVERY ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. THE ENGINEERS MUST COMPLETE AND SUBMIT ALL APPLICABLE 2006 WASHINGTON STATE NONRESIDENTIAL ENERGY CODE COMPLIANCE FORMS TO THE CITY OF TUKWILA. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. 46. 47. CONTRACTOR SHALL LABLE ALL THERMOSTAT BY ITS CORRESPONDING TERMINAL AIR UNIT OR AC UNIT. ALL COMBINATION FIRE /SMOKE DAMPERS SHALL BE FIRE MARSHALL LISTING. CONTRACTOR TO FURNISH FULL SIZE SHOP DRAWINGS SHOWING ALL DUCT ROUTING, EQUIPMENT LOCATIONS, DIFFUSER, & THERMOSTAT LOCATIONS, AND ANY OTHER PERTINENT HVAC ITEMS. FLANGES SHALL BE SUBMITTED AS SHOP DRAWINGS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR PAYMENT OF ALL CHARGES RESULTING FROM ANY ADDITIONS OR CHANGES IN THE WORK OF OTHER TRADES DUE TO DEVIATIONS FROM THE CONTRACT DOCUMENTS. ANY AND ALL CHANGES SHALL BE SHOWN ON RECORD AND AS -BUILT DRAWINGS. PROVIDE DUCT FLEX CONNECTORS ON ALL SUPPLY AND RETURN DUCT CONNECTIONS TO A/C UNITS OR EXHAUST FANS. AREAS ABOVE NONE DUCTED RETURN AIR GRILLED SHALL BE PAINTED FLAT BLACK TO MASK "SEE THROUGH" EFFECT. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND INSTALLED IN ACCORDANCE WITH UMC CHAPTER 6. THIS PROJECT SHALL COMPLY WITH THE 2006 EDITION OF THE INTERNATIONAL BUILDING CODE (TITLE 24). WHICH ADOPTS THE 1997 UBC. SYMBOLS 2 1. LOCATION OF DUCTWORK IS APPROXIMATE. ALL DRAWINGS AND LAYOUTS ARE DIAGRAMATIC INTENT ONLY. CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS SHOWING CABLE TRAY AND BUILDING STRUCTURE. IF FIELD CONDITIONS DIFFER SIGNIFICANTLY , DRAWINGS AND AFFECT MECHANICAL WORK, INFORM ARCHITECT IMMEDIATELY BEFORE AREA. 2. CONTRACTOR SHALL NOTE THE CRITICAL SPACE AVAILABLE ABOVE CEILINGS. PROVIDE CROSSOVERS, UNDER BEAMS, OVER /UNDER PIPES, AS REQUIRED TO ACCOMMODATE AVAILABLE. PROVIDE EQUIVALENT DUCT SIZE TO THE DIAMETER SHOWN. COORDINATE SECTIONS TO REDUCE NECESSITY OF TRANSITION TO A MINIMUM. NO ADDITONAL COSTS REQUIRED TRANSITIONS OR O11 -TER SPECIAL CHANGE SHAPE PIECES. 3. CONTRACTOR IS TO PROVIDE MATERIAL AND LABOR TO PHYSICALLY TEST ALL FIRE AND COMBINATION RESET THEM FOR ITS DESIGN FUNCTION. TESTING PROCEDURES AND TEST RESULTS SHALL BE WITNESSED AUTHORITIES HAVING JURISDICTION. 4. IN CASES WHERE SHEET METAL DUCTS INTERSECT FIRE -RATED WALLS AT OTHER THAN RIGHT ANGLES, THE RATED WALL ABOVE CEILING SUCH THAT THE OFFSET WALL WILL BE PERPENDICULAR TO THE PROVIDED AT THE WALL ACCORDINGLY. 5. ALL NON -RATED DOORS REQUIRERING UNDER -CUT SHALL BE 3/4 INCH MINIMUM, UNLESS NOTED REQUIRING UNDERCUT SHALL BE: DOUBLE DOORS NOT TO EXCEED 1/4" AND SINGLE DOORS NOT TO BE COORDINATED WITH THE ARCHITECTURAL DOOR SCHEDULE AND SPECS. 6. FIRE DAMPERS, COMBINATION FIRE / SMOKE DAMPERS AND THE NECESSARY ACCESS PANELS SHALL PENETRATING FIRE AND /OR SMOKE PARTITIONS AS REQUIRED BY CODE. SEE ARCHITECTURAL DRAWINGS FIRE AND /OR SMOKE RATED PARTITIONS. 7. COMBINATION FIRE /SMOKE DAMPERS SHALL BE PROVIDED FOR SUPPLY AND RETURN AIR DUCTS PENETRATING WALLS /CORRIDORS PER UBC AND UMC. EACH COMBINATION FIRE/ SMOKE DAMPER SHALL BE PROVIDED THAT ARE INSTALLED WITHIN 5' -0" OF THE DAMPER. 8. DUCT SMOKE DETECTORS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN RECOMMENDATIONS BUILDING FIRE ALARM SYSTEM. 9. ALL DUCTWORK SHALL BE SUPPORTED AND SEISMICALLY RESTRAINED PER THE WASHINGTON BUILDING CODE AND SMACNA STANDARD. 10. ALL REQUEST FOR ACCESS OR CONNECTIONS, I THOSE NOTED BELOW MUST BE MADE IN WORK ACTIVITY THROUGH THE BUILDING MANAGEN R. 11. DO NOT MODIFY ANY EXISTING HVAC SYSTEM OR COMPONENT WITHOUT CONTACTING THE BUILDING 12. PROTECT AND MAINTAIN ALL RETURN AIR DUCT OPENING WITH PROPER FILTER MEDIA DURING ALL 13. 2 WM SHALL COMPLY WITH A FOLLOWING: 0H 2006 MECHANICAL CODE WITH WASH INGTON AMENDMENTS 2006 UNIFORM PLUMBING CODE WITH WASHINGTON AMENDMENTS 2006 WASHINGTON STATE ENERGY CODE RECEIV i CORRECTION 2005 NATIONAL ELECTRICAL CODE CITY OF TUKi A LTR# A 2 2888 14. ALL LOCAL CITY CODES MUST BE FOLLOWED. PEF:',3 T CENTER MD TO SHOW DESIGN ALL DUCTWORK, PIPING FROM SHOWN ON THE PROCEEDING WITH THAT TRANSITION PIECES AT DUCTS WITHIN SPACE CLOSELY WITH OTHER WILL BE PAID FOR ANY FIRE / SMOKE DAMPERS AND AND APPROVED BY THE CONTRACTORS SHALL OFFSET DUCT. FIRE DAMPER SHALL BE OTHERWISE. ALL FIRE -RATED DOORS TO EXCEED 3/8 ". ALL UNDER CUTS BE PROVIDED FOR ALL DUCTS FOR THE EXACT LOCATION RATED WITH DUCT SMOKE DETECTORS AND SHALL BE TIED -IN TO THE CODE, UNIFORM MECHANICAL WRITING 48 HOURS IN ADVANCE OF ENGINEER. CONSTRUCTION ACTIVITY. :=..- 1 V. :: �n wA$' _ > f • ` ' : I - ~° -- o - OF -:_ � � 4,. - � � '' h "" w �4 _ ..1&c5 LL' : }� = =, 2006 CALIF. MECHANICAL CODE, 2006 INTERNATIONAL PLUMBING CODE AND THE 2006 INTERNATIONAL ELECTRICAL CODE. 2 THE FIRE RATED CORRIDORS ARE NOT TO BE USED TO CONVEY AIR TO OR FROM ROOMS. UMC SECTION 602.1 (HERE ARE NO ENVELOPE ALTERATIONS TO BE DONE ON THE BUILDING. AIR & WATER BALANCE TO BE PERFORMED BY AN INDEPENDENT AABC CONTRACTOR. AIR BALANCE TO INCLUDE ALL A/C UNITS, VAV'S, BATHROOM EXHAUST FANS AND SUPPLY GRILLES AS REQUIRED. UTILIZE APPROVED BUILDING AIR BALANCE COMPANY. ALL AIR AND WATER BALANCE TO BE IN ACCORDANCE WITH AABC STANDARDS. ALL PIPING AND ASSOCIATED FITTINGS AND VALVES SHALL BE OF SIMILAR MATERIAL PER CODE, UNLESS APPROVED OTHERWISE. PROVIDE DIELECTRIC COUPLING BETWEEN JOINTS OF DISSIMILAR MATERIALS. RUN ALL DUCTS AS TIGHT AS POSSIBLE TO STEEL BEAMS. ALL PIPINGS OTHER THAN CONDENSATE SHALL BE ROUTED ABOVE THE DUCTWORK UNLESS APPROVED OTHERWISE. SPACE THERMOSTATS SHALL BE PER BUILDING STANDARDS AND COMPATIBLE WITH THERMINAL AIR UNIT OPERATORS. ADJUSTABLE SHALL BE 10'F BETWEEN FULL HEATING AND FULL COOLING, OPERATING IN SEQUENCE, SET AT 707 HEATING AND 747 COOLING. COORDINATE FINAL LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. CONTRACTOR SHALL COORDINATE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT THE ELECTRICAL CONTRACTOR PRIOR TO ORDERING. CONTRACTOR SHALL PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND /OR LABOR AT NO COST TO OWNER FOR PERIOD OF ONE YEAR FROM DATE OF OWNER ACCEPTANCE. UPON COMPLETION OF WORK, CONTRACTOR SHALL CLEAN AND REMOVE ALL DEBRIS ASSOCIATED WITH HIS /HER WORK AND DISPOSE AREA SHALL BE LEFT IN A CONDITION ACCEPTABLE TO OWNER. PROVIDE ACCESS PANELS FOR ALL NEW OR EXISTING EQUIPMENT AND VALVES LOCATED ABOVE HARD LID CEILING. CONTRACTOR SHALL SEAL ALL UNUSED DUCT OPENINGS AND REPAIR ALL LEAKING DUCTS AS PART OF THIS WORK. CEILING SPACES USED AS RETURN AIR PLENUMS SHALL FULLY COMPLY WITH ALL THE PROVISIONS OF SECTIONS 601.1 - 601.2. SEAL ALL DUCTS AND JOINTS WITH HIGH VELOCITY, WATER BASED, UL -FIRE RATED DUCT SEALER. CONTRACTOR SHALL SEAL ANY AIR LEAKAGES OR HOLES ON EXISTING DUCTWORKS. REPLACE ANY DAMAGE OR MISSING INSULATION. RUN 1" TYPE L COPPER CONDENSATE DRAIN LINES FROM EACH A/C UNIT TO NEAREST CODE APPROVED RECEPTOR. CONDENSATE DRAIN PIPING INSTALLED WITHIN A RETURN PLENUM SHALL BE NON - COMBUSTIBLE MATERIAL. ALL RETURN AIR IS VIA RETURN GRILLES AND CEILING PLENUM EXCEPT TOILET ROOMS, ELECTRICAL ROOMS AND TUNNEL TYPE CORRIDORS. ALL MATERIAL EXPOSED WITHIN THE PLENUM SHALL COMPLY WITH UMC SECTION 604.2. "MATERIALS SHALL HAVE A MOLD, HUMIDITY EROSION- RESISTANT FACE THAT MEETS THE REQUIREMENTS OF UL 181. COMBUSTIBLE WITHIN THE PLENUM SPACE MUST COMPLY WITH IMC REQUIREMENTS RANGE A OF IT. AND 1 LANDLORD NOTES 6 1. 2. 3. 4. 5. 6. 7. 8. UNLESS INDICATED ON PLANS, THE BASE BUILDING FIRE ALARM & LIFE SAFETY DEVICES ARE TO REMAIN. IF ANY BASE BUILDING DEVICES SUCH AS ELEVATOR CALL BUTTON, FIREMAN'S PHONE JACK, FIRE PULL STATIONS, SMOKE DETECTORS, MAGNETIC DOOR RELEASES, LIFE SAFETY SPEAKERS ETC. ARE SHOWN MOUNTED ON EXISTING PARTITION TO BE DEMOLISHED, CONTRACTOR SHALL RELOCATE SUCH DEVICE TO A NEW LOCATION AS TO MAINTAIN THE FUNCTIONALITY OF THE DEVICES. EXTEND CONDUIT AND TIRING REQUIRED. SUBMIT NEW LOCATION TO ARCHITECT AND ENGINEER FOR APPROVAL ALL NEW FIRE ALARM AND LIFE SAFETY DEVICES, INCLUDING BUT NOT LIMITED TO SPACE DETECTORS, SHALL BE CONNECTED TO BASE BUILDING EXISTING LIFE SAFETY SYSTEM. THE ENTIRE INSTALLATION INCLUDING MATERIALS AND EQUIPMENT SHALL BE COMPATIBLE THE EXISTING SYSTEM. FIRE ALARM AND LIFE SAFETY DEVICES WIRING SHALL BE MINIMUM NO 14AWG COPPER THE FIRE ALARM SYSTEM SHALL CONFORM TO ARTICLE 760 OF INTERNATIONAL ELECTRICAL CODE AND ALL APPLICABLE NFPA STANDARDS. UPON COMPLETION OF THE INSTALLATION OF SYSTEM AND DEVICES, A SATISFACTORY TEST OF ENTIRE SYSTEM SHALL BE PERFORMED THE PRESENCE OF THE ENFORCING AGENCY. ALL HVAC EQUIPMENT INCLUDING EXHAUST FANS, AIR - HANDLERS, AND FAN COIL UNITS SHALL BE STARTED AND STOPPED VIA THE CONTROL SYSTEM ONLY. ANY SIGNAL FROM THE FIRE ALARM SYSTEM SHOULD BE AN INPUT TO THE SMOKE CONTROL SYSTEM VIA THE FIRE ALARM SYSTEM PER BASE BUILDING STANDARDS. THE FIRE -ALARM SYSTEM SHALL BE DESIGN -BUILT BY THE APPROVED BASE BUILDING FIRE ALARM CONTRACTOR. EQUIPMENT SHUT -DOWN: ALL HVAC UNITS, CSFD'S, ETC. SHALL BE INTERCONNECTED TO THE BASE BUILDING AIR CONDITIONING UNIT CONTROL SYSTEM AND THE BASE BUILDING FIRE ALARM SYSTEM AND SHUT DOWN UPON A SIGNAL FROM THE FIRE ALARM SYSTEM AND ACTIVATION OF ANY SMOKE ALARM. AS WITH IN u ° Z° { ,� Y � ` NAL EXPIRES 4 -17 -2009 [ FIRE LIFE SAFETY NOTES 5 MECHANICAL NOTES 4 GENERAL NOTES I 3� NOISIA3a LANDLORD & BUILDING DEPT. REVISIONS I 2600 SOUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION V DESIGNED BY: - DRAWN BY: - 80'94'10 80'OZ - ZO 31da REVIEWED BY: - DATE: 1 2.26.2007 JOB NUMBER: 07935 FILE #: M0.1.DWG SHEET TITLE: HVAC NOTES, SYMBOLS & SHEET INDEX Kaaaa / KENN BU S ISSUE PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL A.I.A• Kenneth L Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAMS, CA 95616 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX L0'9Z'Z l L0'0171 31ba NOISIA3a LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS • ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - 80'94'10 80'OZ - ZO 31da REVIEWED BY: - DATE: 1 2.26.2007 JOB NUMBER: 07935 FILE #: M0.1.DWG SHEET TITLE: HVAC NOTES, SYMBOLS & SHEET INDEX Kaaaa SHEET NUMBER: MO.1 ISSUE PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED, BUILDING DEPARTMENT RE- SUBMITTAL L0'9Z'Z l L0'0171 31ba 80'L0'ZOI BO'OZ•ZD ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 1 2.26.2007 JOB NUMBER: 07935 FILE #: M0.1.DWG SHEET TITLE: HVAC NOTES, SYMBOLS & SHEET INDEX SCALE: AS NOTED SHEET NUMBER: MO.1 / CFM ROUND DUCT DIAMETER CFM ROUND DUCT DIAMETER RANGE OR EQUIVALENT RANGE OR EQUIVALENT RECTANGULAR DUCT RECTANGULAR DUCT 0-110 6" OR 8 "X4" 1400 -1900 18" OR 24 "X12" DE W/ GREASE BOX SEE KITCHEN DRAWINGS 101 -220 8" OR 10 "X6" 1900 -2500 20" OR 24 "X14" 220 -400 10" OR 10 "X8" 2500 -3300 22" OR 32 "X14" 401 -600 12" OR 12 "X10" 3300 -4100 24" OR 36 "X14" 601 -900 14" OR 16 "X10 4100 -5000 26" OR 40 5 X16" 901 -1400 16" OR 18 "X12" 5000 -6200 28" OR 48 "X16" 6200 -7500 30" OR 48 "X18" REMARKS: DUCT SIZES INDICATED ARE INSIDE DIMENSIONS WHICH MAY BE . ALTERED BY CONTRACTOR TO OTHER DIMENSIONS TO AVOID INTERFERENCES AND CLEARANCE REQUIREMENTS. USE EQUAL FRICTION METHOD, O.1 "WG PER 100 FT. OF DUCT TO DETERMINE DUCT SIZES. 0 00 l EXHAUST FAN SCHEDULE 2 DUCT SIZING SCHEDULE (FOR LOW VELOCITY SUPPLY RETURN & EXHAUST DUCT) SCALE: NONE 5 MANUFACTURER ESP ELECTRICAL DATA TOTAL MARK NO. & LOCATION SERVICE FAN TYPE FAN RPM CFM (IN. OPERATING REMARKS MODEL NO. W.G.) HP VOLT PH HZ WEIGHT (LBS.) ® Al - G10 ROOF KITCHEN ROOF MOUNTED 1210 2240 0.5 1.5 480 3 60 500 1. MAKE -UP AIR SYSTEMS ARE REQUIRED FOR ALL EXHAUST SYSTEMS DESIGNED FOR A 0 Q Q MAXIMUM OF 90% OF ALL EXHAUSTED AIR QUANTITY. THE EXHAUST AND MAKE -UP AIR SYSTEMS SHALL BE ELECTRICALLY INTERLOCKED SO THAT ONE SWITCH ACTIVATES BOTH. 2. PROVIDE HEATING, COOLING AND VENTILATION LOAD CALCULATIONS. 3. MAKE -UP AIR UNIT SHALL INCLUDE HEATING. 0 PROVIDE WITH ROOF CURB AND BACK DRAFT DAMPER 1 0 PROVIDE W/ EVAPORATIVE COOLER WIRING HARNESS AND FREEZE PROTECTION DRAIN KIT. SEE KITCHEN DRAWINGS ox - C RECEIVED.. 2 , 2 CITY OF TUKWILA '" APR 2 3 2008 1 „� 28357 PERMIT CENTER ` ` S IONAL ti [EXPIRES 4 -17 -2-0091 LANDLORD NOTES: 6 KITCHEN MAKE -UP AIR UNIT 3 KENN BU A.I.A. Kenneth L Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I OUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON 31VG MARK C CFM RANGE T TYPE S MAX. F FRAME SIZE N NECK M MAX C REMARKS M SYMBOL S SERVICE T TONAGE A MAKE B COOLING CAPACITY G HEATING H HEATING L GENERAL SPECIFICATION W WEIGHT 6 633S el33 AFUE OSA C UNIT DIMENSIONS REMARKS FAN DATA E ELECTRICAL DATA O CURB J JNIT HEIGHT L L x W R SH T TI-1 C CFM E ESP M RPM N HP V NOMINAL M MIN. M MAX. R CD -1 0 0 - 120 S SQUARE 0 0.1 2 24X24 6 6X6 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE S CD -2 1 121 - 220 S SQUARE 0 0.1 2 24X24 8 8X8 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE ( STORE 5 5 4 48GPN0600905 5 56,000 6 60,000 9 90,000 7 70,000 2 2,000 0 0.5" 1 1185 - - 4 480 -3 -60 1 15.4 2 20 8 800 7 78.2 3 300 8 8.0 4 47.0 4 47 X 43 o o a o 0 o a o 0 0 CD -3 2 221- 350 S SQUARE 0 0.1 2 24X24 1 10X10 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE CD -4 3 351 - 500 S SQUARE 0 0.1 2 24X24 1 12X12 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE A AM S CD -6 5 501 - 750 S SQUARE 0 0.1 2 24X24 1 16X16 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE CD -7 7 751 - 900 S SQUARE 0 0.1 2 24X24 1 18X18 2 25 T TITUS MODEL PMC, PERFORATED SUPPLY, MODULAR CORE CD -13 0 0 - 500 S SQUARE 0 0.1 1 12X12 8 8X8 3 35 T TITUS MODEL 300FS, ALUMINUM SUPPLY GRILLE CR -1 0 0 - 80 S SQUARE 0 0.1 2 24X24 6 6X6 2 25 T TITUS MODEL PMR, DUCTED PERFORATED RETURN V INSTALLATION SHALL BE PER MANUFACTURER'S RECOMMENDATION CR -2 8 81 - 200 S SQUARE 0 0.1 2 24X24 8 8X8 2 25 T THUS MODEL PMR, DUCTED PERFORATED RETURN CR-3 2 201 - 320 S SQUARE 0 0.1 2 24X24 1 10X10 2 25 T TITUS MODEL PMR, DUCTED PERFORATED RETURN V CR -4 3 321 - 450 S SQUARE 0 0.1 2 24X24 1 12X12 2 25 T TITUS MODEL PMR, DUCTED PERFORATED RETURN P cR -5 4 451 - 700 S SQUARE 0 0.1 2 24X24 1 16X16 2 25 T TITUS MODEL PMR, DUCTED PERFORATED RETURN CR -6 7 701 - 1000 S SQUARE 0 0.1 2 24X24 1 18X18 2 25 T TITUS MODEL PMR, DUCTED PERFORATED RETURN Q CR -7 0 0 - 1000 S SQUARE 0 0.1 2 24X24 - - 2 25 T TITUS MODEL PXP, NON- DUCTED PERFORATED RETURN ® EG -1 0 0 - 300 S SQUARE 0 0.1 1 12X12 8 8X8 3 30 T TITUS MODEL 355RL, EXHAUST GRILLE ® LD -1 0 0 - 400 L LINEAR /SUPPLY 0 0.1 6 60" X 4" 1 10 "0 2 25 T TITUS FLOW BAR, FL -25 (SINGLE SLOT, 2.5" W/ 5' PLENUM 0 LR -1 1 100 CFM /FT. L LINEAR /RETURN 0 0.1 7 72" X 4" 1 1O "0 2 25 T TITUS FLOW BAR, ft-25 (SINGLE SLOT, 2.5" W/ 6' PLENUM ® NOTES: LOOK, LOCATION, AND COLOR SCHEME SHALL BE COORDINATED AND 1. FINAL DIFFUSER L PACKAGE GAS /ELECTRIC AIR CONDITIONING UNIT (8" HIGH CURB) 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY -1 2008 City Of Tukw MARK NO. L LOCATION S SERVICE F FAN TYPE F FAN RPM C CFM ELECTRICAL DATA HP V VOLT P PH H HZ PACKAGE GAS /ELECTRIC AIR CONDITIONING UNIT (8" HIGH CURB) SCALE: NONE 4 4 NCA16FA R ROOF H HOOD R ROOF MOUNTED 1 1031 2 2800 1 1.0 1 1.5 4 480 3 3 6 60 5 5' KENN BU A.I.A. Kenneth L Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I OUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON 31VG 80'OZ'ZO 20'9 1'i'0 3nssl PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED. BUILDING DEPARTMENT RE- SUBMITTAL 31ba I L0'0 VZ 1 I L 09 Z' Z l 1 REVISION LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I 31VG 80'OZ'ZO 20'9 1'i'0 3nssl PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED. BUILDING DEPARTMENT RE- SUBMITTAL 31ba I L0'0 VZ 1 I L 09 Z' Z l 80'LO'ZO I 1 02.20.08 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: -- CHECKED BY: - REVIEWED BY: - DATE: 12.26.2007 JOB NUMBER: 07935 FILE #: M0.2.DWG SHEET TITLE: HVAC EQUIPMENT SCHEDULE SCALE: AS NOTED SHEET NUMBER: MO.2, REVISION _ I LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I 1/4 "0 SET SCREW STANDING SEAM MASTIC SEALANT ISSUED FOR PERMIT DRAIN, 10' DOWNSTREAM FROM TRAP C.O. EQUIPMENT DRAIN iiva 90'0Z'Z0 80'9 4'1'0 ISSUED FOR: DESIGNED BY: - DRAWN BY: 3" MINIMUM • ' 1 I 1 I PAN PITCH DOWNWARD TOWARDS - Kenneth L Architect 124 STAGECOACH BELL CANYON, TEL (818) FAX. (818) 12.26.2007 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION 3/8" SQUARE ROD DRAIN @ 1/4" PER FOOT 310 576 1553 PHONE 310 576 1569 FAX 6 nva L 71 I T 1 02.07.08 20 GAGE SHEET METAL FLASHING BY MECH. CONTRACTOR. ROOF Cf0 AIR DUCT FOR SIZES SEE FLOOR PLAN x i " ���� . �' j 1"x1/8" GALVANIZED STRAPS x SPOTWELD TO BLADE r L SHEET 3 " MIN. LAG SCREWS C.O. C.O. 1/4 " LESS THAN _ 16 GAUGE GALVANIZED BLADE I VENTLOCK NO. 609 III B ' -^ CURBED ROOF SPILL OVER RECEPTACLE 0 2" ABOVE FLOOR CONN INTO FIXTURE TAILPIECE A = S.P. B = S.P. S.P. = A DI- ELECTRIC COUPLING/ DUCT DIAMETER OPENING BY GEN. STRUCRAL FRAMING DUCT UNING WHERE NOTE: CONTRACTOR PLANS SEE FOR SIZES SECTION A -A ♦ J UNION (AS REQUIRED) 3/8" SQUARE ROD END BEARING �l I --, GASKET (TYPICAL 2) la- OR x 1.5 + 2" x 0.5 + 2" MAX. NEGATIVE STATIC PRESSURE -•• INCHES . � 2" MIN DRAIN LINES SHALL BE SIZED AS FOLLOWS TONS SIZE () INDICATED H1 /2 CLE MIN. AR ALL AROUND /_ 1. ALL DUCT PENETRATIONS THROUGH ROOF OR RATED WALLS SHALL BE FIRE- STOPPED WITH VENTLOCK NO. 607 1---11 END BEARING FOR - = INSULATED DUCT PLAN VENTLOCK NO. 638 REGULATOR DRAW 0 -3 3/4 " 4 -20 1" 21 -90 1-1/4" * BUT NOT LESS THAN THE FULL SIZE EQUIPMENT CONN. THRU FOR INSULATED DUCT, VENTLOCK No.635 FOR UNINSULATED DUCT. HILTI CP -601S. SEAL WITH AN APPROVED FIRE STOPPING COMPOUND WITH THE FOLLOWING APPROVAL NUMBERS OR EQUAL A. I.C.B.O DER -5614 B. CA STATE ARE MARSHALL #1452- 1200:112 C. UL #2079 AND 1479 INDICATING HANDLE DUCT PENETRATION THROUGH ROOF 7 CONDENSATE DRAIN CONNECTION DETAIL 4 ROUND VOLUME DAMPER UP TO 14 "DIA. 1 24 INCH STRAP HANGER BAND (2) 1 "x18 GA HANGER RODS CODE COM a APP LOAD RATED 0 FASTENER DIA. MAX. INSULATED FACTORY PLENUM—i.. FLEXIBLE DUCT TO COLLAR (WIRE HANGERS NOT PERMITTED) 50 INCH DIA. MAX. `� NOTES SHEET METAL OR FLEXIBLE DUCT AS SPECIFIED �t(�a lit-11 A�( 1. USE FOR SYMBOL 1 WHERE BRANCH DUCT AIR QUANTITY LESS THAN 25% OF THE TOTAL AIR FLOW. �� /i• ROUND VOLUME DAMPER FOR LOW PRESSURE BRANCH DUCT ONL ° Ill SEE DETAIL 10 BELOW O SO ON ® � D BAND (2)1"x16 GA J OVER 50 INCH DIA. NOTE: � i�IN 2. DEPTH OF MAIN DUCT MUST BE 2" LARGER THAN CONICAL DIAMETER. CONICAL TAP THIS PARTICULAR TYPE OF LINEAR IS ANCHORED BY HARD CEILING CUP WITH 1/8 "0 MOUNTING SCREWS MAX. @I 10" MAX. ON CENTERS AND SCREW TO THE CEILING FRAME 41166E-7 NOTES:, MAIN DUCT 1. FOR HANGER SIZE AND SPACING, SEE SMAGNA HVAC DUCT CONSTRUCTION STANDARDS TABLE 4.2 2. FOR UPPER ATTACHMENT TO BUILDING SEE SMACNA HVAC DUCT CONSTRUCTION STANDARDS FIG. 4-1 AND RIG. 4-2, WITH SPECIFIC BUILDING STRUCTURAL ENGINEER APPROVAL 3. FOR BRACING AND OTHER SEISMIC REQUIREMENTS SEE GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS AND PLUMBING PIPING SYSTEMS PUBUSHED BY SMACNA AND PPIC. ALSO REFER TO NATIONAL UNIFORM SEISMIC INSTALLATION GUIDELINES (NUSIG) 1991 AS APPROVED BY OFFICE OF THE CAUFORNIA STATE ARCHITECT 9/25/92. AM& AIR FLOW HARD CEILING CUP — CEIUNG FRAMING 12X12 -113" EMBED H . - PATTERN CONTROLLER SPACKLE GYP BOARD TYPICAL HORIZONTAL ROUND DUCT SUPPORTS 8 LINEAR SLOT DIFFUSER INSTALLATION DETAIL 5 CIRCULAR DUCT LATERAL TAP WITH VOLUME DAMPER DETAIL 2 MODULAR OUTDOOR DOWN DISCHARGE BLOWER WITH EVAPORATIVE COOLER AND INTAKE HOOD 1. ALL ROOF PENETRATIONS SHALL COMPLY WITH BULLETIN 10 - TENANT DESIGN CRITERIA. TENANT MUST UTILIZE (AT TENANTS EXPENSE) THE LANDLORD'S DESIGNATED ROOFING CONTRACTOR TO COMPLETE ALL WORK. FLEX CONDUIT 0 1 -1/2 IN WATER DRAIN FOR FIELD 7- WIRING AIRFLOW 01/2 IN ** NPT WATER CONNECTION ° 1 _ _� Y T V o � w as fi t , �� �a ~ ����- _ = 7- 28357 W 7. RECEIVED CITY OF TUKWILA =� App 23200E °� � � -- � 5Y ONAL V' PERMIT CENTER O I ° ° r I CURB x LIFTING LUG OUTER WALL BLOWER DISCHARGE SERVICE DISCONNECT SWITCH t a 00 - 4 BLOWER/ BLOWER/ MOTOR ACCESS DOOR .. .• FILTER/ CONTROL ACCESS DOOR . . . . I• INTAKE HOOD . -I- 20 IN HIGH EQUIPMENT CURB ROOF OPENING 2" SMALLER THEN CURB DIMENSION UNIT INFORMATION ALL DIMENSIONS ARE NOMINAL AND GIVEN IN INCHES. MODEL CFM RANGE EVAP. COOLING UNIT CELDEK EVAPORATIVE COOLING UNIT UNIT DIMENSIONS DISCHARGE OPENING WATER INLET DRAIN OPENING MIN MAX NOZZLES MAX. FLOW RATE TOT. WEIGHT MEDIA SIZE QTY VEL. @MAX CFM MODEL A B C ❑ E F J N P R S U W X Y � G1p 0 3500 6 12 GPH 330 LBS 20 "x24 "x12" 1050 FPM G10 64 -3/8 27 -3/8 29 -3/4 26 -1/16 3 -3/4 44 -3/8 21 13-1/4 11 -1/2 3 -7/8 1-3/4 4 -1/2 6 -1/4 13 16 " MAX. EVAP WATER PRESSURE = 50 PSI @ 70 DEG. F EXPIRES 4 -17 -2009 I `I -Ia KITCHEN MAKE -UP AIR UNIT 6 LANDLORD NOTES: 3 REVISION _ I LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I OUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION iiva 90'0Z'Z0 80'9 4'1'0 ISSUED FOR: DESIGNED BY: - DRAWN BY: - KENN BUTTS A.N.A. Butts ROAD CA. 91307 999 4272 999 4321 - REVIEWED BY: - Kenneth L Architect 124 STAGECOACH BELL CANYON, TEL (818) FAX. (818) 12.26.2007 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX REVISION _ I LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION iiva 90'0Z'Z0 80'9 4'1'0 ISSUED FOR: DESIGNED BY: - DRAWN BY: - r‹‹«< - REVIEWED BY: - DATE: 12.26.2007 JOB NUMBER: « FILE #: 3nssl PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED. BUILDING DEPARTMENT RE- SUBMITTAL SHEET NUMBER: MO.3 nva L 71 I LO'9Z'Zl 1 02.07.08 90 I ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 12.26.2007 JOB NUMBER: 07935 FILE #: M0.3.DWG SHEET TITLE: HVAC DETAILS SCALE: AS NOTED SHEET NUMBER: MO.3 013 3 " ► ► ►i ► ► ►► ► ► ►► ►► ► ►p ►► % % =� I �/ / .� /i /� ►► ► ► ► � /�► / / A MAXIMUM SPACING 16" EACH WAY (TYPICAL) DUCT LINING ALL EDGES OF LINING COATED WITH ADHESIVE TYPICAL STUD - WELDED PINS AND SPEED CUP WASHER SEE DETAIL A " NOT MORE THAN 3 FRO EDGES OF LINING ISSUED FOR: a0 SH METAL PROVIDE 1/8" CLEARANCE BETWEEN ARE RATED PARTITION SLEEVE AND PARTITION FOR EACH STEEL LINTEL ON ALL FOUR SIDES; FOOT OF DAMPER HEIGHT AND WIDTH OPENING TO BE LINED WITH FIRE- ON ALL FOUR SIDES. SEAL CLEARANCE RESISTIVE MATERIAL OF RATING WITH RESILIENT CAULKING 20'0Z'ZO --/ D FLEXIBLE DU CT AS SPECIFIED EQUAL TO THAT ON THE SHEET TITLE: HVAC DETAILS �� R i PARTITION (NOT REQUIRED FOR MASONRY OR CONCRETE WALLS) MANUFACTURER FURNISHED SLEEVE "S" 1<<K1<< ROUND VOLUME DAMPER SEE DEl`AIL LATERAL TAP TYPE SUP CONNECTION, TYP. FUSIBLE PERIMETER MOUNTING ANGLES FASTEN TO SLEEVE ON ALL FOUR SIDES. GAUGE AND SIZE PER LINK ASSEMBLY ELECTRIC ACTUATOR Kenneth L Architect 124 STAGECOACH BELL CANYON, TEL (818) FAX. (818) i l�r��� ■ f MANUFACTURERS TERMS OF LISTING. NGLISTING. " SYSTEM R -D 39371 SPANISH BAY PLACE MAIN , FOR PROJECT COORDINATION «. 2- � KIM KIMIAGAR 310 576 1553 PHONE ■ — 80'0Z70 I DUCT FIRE SMOKE DAMPER ACCESS DOOR O NOTES SPEED CUP WASHER PRESSED DOWN TO UNING SPECIFIED) PRESSED DOWN OVER GRIP -PIN ADHESIVE OVER ENTIRE INNER SURFACE OF DUCT 1 1 01. /k1 i i � . �+ i SENSOR" DH400 DUCT MTh. SMOKE DETECTOR. "°a� �� l� FOR NOSING AT DAMPERS, — — 1 , \ �� ' MOUNT WITHIN 5' TURNING VANES, ACCESS DOORS AND EQUIPMENT, SEE ACOUSTIC r �%li MOTOR MOUNTING 0 : � � OF DAMPER. NOTES: NOTE: UNING NOSING DETAIL BRACKET MIN # � d 3" ACCESS DOOR MINIMUM SIZE MIN G 1) PROVIDE CEILING MOUNTED REMOTE LED ANUNCIATOR. UNING EDGES AT TRANSVERSE AND LONGITUDINAL JOINTS SHALL BE COATED AS SPECIFIED. DETAIL A - WELD PIN STUD WELDED TO DUCT (PINS FASTENED TO DUCT WITH ADHESIVE NOT APPROVED) 1" SMALLER THAN DUCT HEIGHT, 2) CSFM LISTING: 03225 - 0368:110 & 111 EXPOSED ENTERING AND TRAILING EDGES SIMILAR TO ACCESS DOOR DETAIL SEE ACOUSTIC LINING NOSING DETAIL NOT LESS THAN TWO PINS ON EACH FACE OF DUCT. 12" MINIMUM LENGTH, W/ ACCESS DOOR LABEL LOCATE AS REQUIRED FOR EQUIP. ACCESS. 16 " 3) "POTTORF" FSD -172 W/ SHUNT ACTUATOR (10W) U.L USTED USE FOR SYMBOL J._ WHERE BRANCH DUCT IS ROUND FROM ROUND T AIR QUANTIITYB IS ANCH OR LESS OF TOTAL AIR FLOW. ACOUSTICAL LINING INSTALLATION DETAIL 7 COMBINATION SMOKE /FIRE DAMPER DETAIL 4 CIRCULAR DUCT CONICAL TAP WITH VOLUME DAMPER DETAIL 1 MAXMIUM 6 FT FLEXIBLE DUCT FULLY EXTENDED GASKETING CODE C®4 � ov ® .1 2 MQ a 1 -3/4 (QTY. AS TIE DOWN %gal ROUND DUCT CONNECTOR 1111 19 -1/2 /12 SHEET METAL SCREWS ■ 4 ' r -- -- -- -- - - 14 GA TOP RAIL SEISMIC TIE ACOUSTIC LINING DIFFUSER NECK DOWN STRAPS 18 GA. w SIZE I ����� SHEET METAL OR -��ila FLEXIBLE DUCT AS SPECIFIED C1$� ROUND VOLUME DAMPER 1 3 111)1 01 FOR LOW PRESSURE BRANCH DUCT ONLY - LEVELING BOLT T 0 UN 3 VIBREX MODEL j RMU -EQ-SH VIBRATION / = _`, ! : ISOLATOR (SEE NOTES) ` O o t + �, CEILING 6" MINIMUM D 5EE DETAIL 10 BELOW o 0 10 1'2' CONTINUOUS L NEOPRENE WEATHERSEAL STIFFENER PLATE , m ! � . __,,, • ACCESS PORT DIFFUSER SIDE CONNECTION MAXIMUM 6 FT LENGTH FLEXIBLE r, CONICAL TAP DUCT FULLY EXTENDED D MINIMUM 1.11111 ROUND DUCT ADAPTOR 111% D MAIN DUCT WOOD NAILER EA OR EACH ISOLATOR ACCESS R=D 12 GA BOTTOM CURB O PORT COVER 7/16 " DIA. ANCHOR BOLT HOLE QUANTITY AS REQUIRED AIR I► FOR RECTANGULAR f I I - I I IIz FLOW DIFFUSER THERMAL INSULATION /12 SHEET METAL SCREWS \cr NOTES: 1. VIBRATION ISOLATOR /SEISMIC RESTRAINTS 2. WHEN REQUIRED, CURBS ARE PITCHED TO MATCH ROOF SLOPE. a 2 3/4 IN. MINIMUM NOTES I / L L. 1 Jr --r>..) , \ j 1 USE FOR SYMBOL AIR -. W HE RE IS LESS THAN 25% OF THE t . TOTAL AIR FLOW. 2. DEPTH OF MAIN DUCT MUST BE 2" LARGER THAN CONICAL DIAMETER. CEILING DIFFUSER TOP CONNECTION DIFFUSER CONNECTION DETAIL g ROOFTOP AC UNIT'S VIBRATION ISOLATED CURB DETAILS 5 CIRCULAR DUCT LATERAL TAP WITH VOLUME DAMPER DETAIL 2 1. MAXIMUM LENGTH OF FLEX DUCT IS 5' -0 ". 2. ALL ROOF MOUNTED KITCHEN EXHAUST FANS, WHICH HANDLES A GREASE DISCHARGE, MUST BE PROVIDED WITH A CATCH PAN AND GUTTER, WHICH IS PIPED, BACK TO THE TENANT'S GREASE INTERCEPTOR. NCAFA SERIES UPBLAST EXHAUST FANS (UL762) FEATURES: SLOPE DUCT TO HOOD MIN. 1 /4" PER LINEAL FT w -ROOF MOUNTED FANS — RESTAURANT MODEL D VENTED —r-- HT , UL762 — AMCA SOUND AND AIR CERTIFIED —IMRING FROM DISCONNECT SWITCH 4' — MINIMUM VELOCITY 1500 FPM EXHAUST FAN / - - wEATHERP a0F DISCONNECT - HIGH HEAT OPERATION 300E (149'C) -- GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY + FIRE PROVIDE RATED ENCLOUSER FOR THE — ENTIRE DUCTW 1l I 7-ROOF I C GREASE DRAIN 20 GAUGE STEEL CONSTRUCTION • WHILE EXHAUSTING AIR AT 300F (14n) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY � DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. 3" FLANGE ABNORMAL FLARE -UP TEST VENTILATED SHAFT CEILING Iffli' B 2G EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS RO ROOF OPENING AT 600E (316'C) FOR A PERIOD OF DIMENSIONS 15 MINUTES WITHOUT THE FAN BECOMING RO DAMAGED TO ANY EXTENT THAT COULD CAUSE I ATTIC R AN UNSAFE CONDITION. OPTIO PITCHED CURBS ARE AVAILABLE 7 1. 18" MIN. r---- SPACE CLEAN OUT DOORS IN D UCTS SHALL BE TIGH FITTING FIRE RESISTIVE SHAFT ACCESS OPENING EQUIPPED W/ TIGHT FITTING SLIDING OR HINGED DOORS HAVING A FIRE RESITIVE RATING EQUAL TO SHAFT ENCLOSURE - G =R +3" RO FOR PITCHED ROOFS. GREASE BOX 30° HINGED F AN C FLASHING COOKING SURFACE PITCHED CURB SPECIFY PITCH: 12 NCAFA BELT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA INSULATED CURB EXAMPLE 7/12 PITCH = 30' SLOPE DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) CURB DIMENSIONAL DATA 1 1 FAN MODEL HT W B C F R RO WEIGHT LB FAN MODEL D E -� I a v t� =- ox Was �` � a - RECEIVED _ CITY OF TUKVVILA y 15 78857 0 44 � �, ° APR 2 3 2008 6 PERIVI1T CENTER - .;. . . NCA16FA 33 3 4 / 39 3 8 / 2 28 23 1 /2 16 1 2 / 24 190 NCA16FA C fiFA 26 1 2 / 20 WIRES 4-17-2009 r •- % LANDLORD NOTES 9 UPBLAST KITCHEN EXHAUST FAN 6 KITCHEN EXHAUST HOOD WITH UPBLAST FAN DETAIL 3 REVISION I LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I ISSUED FOR PERMIT OUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - P'i 20'0Z'ZO $30'91. JOB NUMBER: 07935 FILE #: M0.4.DWG SHEET TITLE: HVAC DETAILS SCALE: AS NOTED SHEET NUMBER: MO.4 1<<K1<< KENN BUTTS A.I.A• Butts ROAD CA. 999 4272 999 4321 91307 Kenneth L Architect 124 STAGECOACH BELL CANYON, TEL (818) FAX. (818) 3nssl PERLIMINARY DRAWINGS SUBMITTAL Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT®COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX 1 02.07.08 REVISION I LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - 31VO 20'0Z'ZO $30'91. JOB NUMBER: 07935 FILE #: M0.4.DWG SHEET TITLE: HVAC DETAILS SCALE: AS NOTED SHEET NUMBER: MO.4 1<<K1<< 3nssl PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED. BUILDING DEPARTMENT RE- SUBMITTAL 31VO I L0' L0'9Z•Z L 1 02.07.08 80'0Z70 I ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 12.26.2007 JOB NUMBER: 07935 FILE #: M0.4.DWG SHEET TITLE: HVAC DETAILS SCALE: AS NOTED SHEET NUMBER: MO.4 REVISION 1 LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I ISSUED FOR PERMIT OUTHCENTER MALL, SPACE # FC -1 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - I 31da 80'OZ70 80'94'170 JOB NUMBER: 07935 FILE #: M1.1.DWG SHEET TITLE: HVAC FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: ® 1 1<<K1<<<<<< KENN BUTTS A.I.A. / Kenneth L Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 BUILDING DEPARTMENT RE- SUBMITTAL Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS. CA 95616 E -MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX REVISION 1 LANDLORD & BUILDING DEPT. REVISIONS I BUILDING DEPT. REVISIONS I ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - I 31da 80'OZ70 80'94'170 JOB NUMBER: 07935 FILE #: M1.1.DWG SHEET TITLE: HVAC FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: ® 1 1<<K1<<<<<< 3nssl PERLIMINARY DRAWINGS SUBMITTAL HEALTH DEPARTMENT SUBMITTAL LANDLORD NOTES ADDED. BUILDING DEPARTMENT RE- SUBMITTAL 3140 LO'O l'Z 4 I 1 52.26.07 1 02,07.08 80'OZ7O I ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 12.26.2007 JOB NUMBER: 07935 FILE #: M1.1.DWG SHEET TITLE: HVAC FLOOR PLAN SCALE: AS NOTED SHEET NUMBER: ® 1 HVAC PLAN - SPACE FC -1 24X12 24X12 SA. (TYP.) 1. MAINTAIN MINIMUM 10 FT. CLEARANCE BETWEEN EXHAUST FAN DISCHARGE AND OUTSIDE AIR INTAKE. 2. ALL SUPPLY AND RETURN GRILLES IN FORWARD SELLING AREA SHALL BE PAINTED TO MATCH CEILING. 3. GREASE EXHAUST OUTLETS SHALL BE UP -BLAST TYPE AND SHALL BE INSTALLED SUCH THAT THE OUTLET I S EVEN WITH THE TOP OF SCREEN WALLS FOR ROOFTOP MECHANICAL AREAS. 4. ALL ROOF MOUNTED KITCHEN EXHAUST FANS, WHICH HANDLES A GREASE DISCHARGE, MUST BE PROVIDED WITH A CATCH PAN AND GUTTER, WHICH IS PIPED, BACK TO THE TENANT'S GREASE INTERCEPTOR. KITCHEN GREASE EXHAUST DUCTS SHALL BE INSULATED WITH FIRE RATED TYPE INSULATION OR RATED CHASE PER NFPA STANDARDS, LANDLORD'S INSURANCE CARRIER'S REQUIREMENTS AND UL RATING PER CODE REQUIREMENTS. KITCHEN GREASE EXHAUST DUCTS SHALL BE FABRICATED IN ACCORDANCE WITH ALL CODES AND SHALL BE MIN. 18 GAUGE STEEL WITH SMOOTH WELDED JOINTS. ACCESS DOORS SHALL BE ON VERTICAL SURFACE OF THE HORIZONTAL RUN, BOTTOM OF VERTICAL RISER, AND PER LOCAL CODE. AUTOMATIC AND MANUAL SHUT -DOWN FUEL OR POWER SUPPLY MUST BE PROVIDED. KITCHEN HOODS SHALL HAVE AN INDEPENDENT FIRE SUPPRESSION SYSTEM WITHIN THE HOODS PER LOCAL CODE. ALL TENANT EQUIPMENT, ON THE ROOF, SHALL BE LABELED WITH TENANT'S NAME AND SPACE NUMBER. KITCHEN VENTILATION NOTES: SCALE: 1/2 "- "'1' -0" MECHANICAL SPECIFIC NOTES NUN II 0 LANDLORD NOTES: 9 / 0 5 C LR -1 600 (TYP. 22x14 DN. 5. ALL THE COMBUSTIBLE MATERIALS SHALL BE MINIMUM 18" AWAY FROM ALL THE GREASE DUCTWORKS. PROVIDE INTERNAL DUCT LINING IN LIEU OF FLEXIBLE DUCTWORK AS REQUIRED TO MAINTAIN THE CLEARANCE. 6 PROVIDE FIRE RATED WRAP FOR THE ENTIRE EXHAUST DUCT SYSTEM. 7. SEE KITCHEN DRAWINGS FOR INSTALLATION DETAILS OF THE EXHAUST AND MAKE -UP FANS. FC1 PART AL 1. GREASE EXHAUST AIR DUCT SHALL SLOPE A MINIMUM 1/4" PER FOOT OF HORIZONTAL DUCT (2% SLOPE). PROVIDE CLEANOUT ACCESS DOORS IN BOTH RATED ENCLOSURE AND WELDED STEEL OR STAINLESS STEEL GREASE DUCT AT VERTICAL FACE NEAR AT ALL LOW POINTS (TYP.). 2. ALL GREASE EXHAUST DUCT SHALL BE 16 GAUGE BLACK STEEL CONCTRUCTION. GREASE EXHAUST DUCTS SHALL BE AIR AND LIQUID TIGHT WELDED CONSTRUCTION. 3. INTERLOCK MAKE -UP AIR UNIT WITH KITCHEN EXHAUST FAN TO OPERATE THE UNITS AT THE SAME TIME. 4. CONTRACTOR SHALL PROVIDE SPECIAL INSPECTION AND PERFORMANCE TESTING PER LOCAL CITY REQUIREMENTS AND IMC SECTIONS 507.16, 507.16.1, 507.13 AND 508.1. 8. KITCHEN HOODS SHALL INTERLOCK WITH THE COOKING APPLIANCE SO THAT THEIR MAKE UP AIR SYSTEM AND EXHAUST FAN SHALL BE ACTIVATED AUTOMATICALLY WHENEVER COOKING OPERATIONS OCCUR, AS SPECIFIED IN THE MECHANICAL CODE. (2006 IMC 502.2.1.1 & 508.1) • 2 16X14 SARA DN. v 20X12 DN. C -. SE VAC ROOF PLA\ SCALE : 1/4" = 1' -0" AAo (1 K AC » TON KITCHEN EXHAUST DUCT SHALL BE PROVIDED W/ CODE APPROVED FIRE RATED WRAP. SLOPE DUCT TOWARD THE HOOD CONTRACTOR TO COORDINATE THE LOCATION OF THE HOOD W/ KITCHEN CONSULTANT EXISTING MECHANICAL ROOM ON THE ROOF. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL MECHANICAL EQUIPMENT INSIDE THE ROOM AND RELOCATE THE THE EQUIPMENT AS REQUIRED. MAINTAIN A MIN. OF 10' CLEARANCE FROM EXHAUST DISCHARGE AIR TO OUTSIDE AIR INTAKE TO THE UNITS. COORDINATE LOCATION OF ROOF OPENINGS W/ ARCH, LANDLORD AND STRUCTURAL ENGINEER. RECEIVED CITY OF TUKWILA APR 2 3 2008 PERMIT CENTER 1 4- 17.20091 2