Permit M08-043 - WESTFIELD SOUTHCENTER MALL - CHICKEN NOW
CHICKEN NOW 2600 SOUTHCENTER MALL FC -11 M08 -043 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Value of Mechanical: $9,000.00 Type of Fire Protection: doc: IMC-10/06 CRAW' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 2600 SOUTHCENTER MALL TUKW MECHANICAL PERMIT CHICKEN NOW 2600 SOUTHCENTER MALL FC -11 , TUKW LA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contact Person: Name: BOB ROBINSON Address: 37936 23 PL S , FEDERAL WAY WA Contractor: Name: SOUND HEATING & A/C INC Address: 5209 122 ST E , TACOMA, WA Contractor License No: SOUNDHA066BM DESCRIPTION OF WORK: REFRIGERATION, DUCTING, FAN HOOD, AND OTHER MISCELLANEOUS KITCHEN EQUIPMENT Furnace: <100K BTU > 100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 0 0 0 1 0 1 0 0 * *continued on next page ** M08 -043 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 677 -6874 Phone: 253 - 535 -6249 Expiration Date: 08/15/2009 M08 -043 06/24/2008 12/21/2008 Fees Collected: $271.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 1 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06-24 -2008 Permit Center Authorized Signature: Signature: Print Name: doc: IMC -10/06 le=v70 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us (J:J21_ Permit Number: M08 -043 Issue Date: 06/24/2008 Permit Expires On: 12/21/2008 Date: L2' 1 4 'v O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or theprformance of work.I am authorized to sign and obtain this mechanical permit. Date: (p- . fS This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -043 Printed: 06-24 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 11: ** *FIRE DEPARTMENT CONDITIONS * ** doc: Cond -10/06 • City of Tukwila Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: CHICKEN NOW Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: M08 -043 Status: ISSUED Applied Date: 02/15/2008 Issue Date: 06/24/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors m the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire- extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire- extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 14: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) M08 -043 Printed: 06-24 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15: Local U.L. central station supervision is required. (City Ordinance #2051) 16: All new automatic fire- extinguishing systems and all modifications to existing automatic fire- extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 17: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 23: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 24: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 25: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 26: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 29: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) doc: Cond -10/06 M08 -043 Printed: 06 -24 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -043 Printed: 06 -24 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: �O.C17•1 7 vi ¢ J4 2 y doc: Cond -10/06 M08 -043 Date: �o- i 44-0 E> ordinances governing or local laws regulating Printed: 06-24 -2008 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://linviv.ci.tulavilaiva.us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: lar --3c LM1 Cellfp Tenant Name: M l( V∎10K/ / c — k 4011/ U Property Owners Name: v V E5'�Fi �( �,�`� ([ � ^ C7( t Jt A Mailing Address: 1 ( t 2() `'V 1 LS - 11-1.12,8 - B L D LC6 A P\)b E `}1 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Contact Person: E -Mail Address: Contractor Registration Number: • Building Permit No. ' O Mechanical Permit No. ' A(} S -0 3 Plumbing/Gas Permit No. - RC, () (1 -o 1-t '-i Public Works Permit No. Project No. City 1 OS OBI (For office use only) King Co Assessor's Tax No.: 636, - 4 - tan " I 0 Suite Number — I I Floor: i t New Tenant: Yes ❑ ..No Cit c — State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: 1 3 RCE4 W7CIN FORM 17 � L - - ) Day Telephone: t z 5 67 7 14307+ Mailing Address: - ‘ 7 ( 2 12L e L S 1 why im ci :-.3 ��, City State / ,� Zip E -Mail Address: pert 11if l G 1��C'if ra1C?cisi Y) P T Fax Number: 9 c3- �G�c✓ / ' -(41 Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: V Ib 11 t 7 '.f.f..s 4 tTtC7 ` Mailing Address: 1 D t i r e AM Contact Person: f V 1P rT �ATT — TAMPA - City State Zip �3 Day Telephone: 7S z( 333 E -Mail Address: Fax Number. ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: 1` - t t �T 1.fV =0 W/1 - �(0IJ F L. Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: QMpphcauons\Fmms- Applications On Iine\3 -2006 - Pemm Apphcationdoc Revised: 9 bh State Page 1 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial indirect waste Clothes washer, domestic Floor drain f Sinks '2- Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent ' Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors , Repair or alteration of water piping and /or water treating equipment I Repair or alteration of drainage or vent piping t 1 Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPIN ERMIT INFORMATION - 206 - 431 - 670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Valuation of Plumbing work (contractor's bid price): $ �t COV Valuation of Gas Piping work (contractor's bid price): $ L/, O Scope of Work (please provide detailed informatiqn): L/I C Z 'OW y / 3 erf.s 00t-( Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: - l u & LL.) t (.lk Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q: Applications\Fomu- Applications On Line - Permit Applicationdoc Revised: 9 -2006 bh City State Zip Day Telephone: Fax Number: Expiration Date: Sewer: T L? iA.) I L. Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING R AUTHORIZED AGENT: Signature: - ✓Ii ( 1 Print Name: 43r.43 V.051 Mailing Address:374 3 0 Z3rd Date Application Accepted: (S - Os Q:\Applications\Fonns- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh (17 PUe..8> S F WAY City Date: 2 /41b 6 Day Telephone: G 7•7-4._. 74' WA- ll'uo State Date Application Expires: Staff Initials: Zip L,t4 I Page 6 of 6 Payee: SOUND HEATING ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Met hod Descriptio Amount Payment Cash 224.50 RECEIPT Parcel No.: 6364200010 Permit Number: M08 -043 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/15/2008 Applicant: CHICKEN NOW Issue Date: Receipt No.: R08 -02257 Payment Amount: $224.50 Initials: WER Payment Date: 06/24/2008 11:48 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 217.00 000/345.830 7.50 Total: $224.50 4012 06/24 9710 TOTAL 224.50 doc: Receipt -06 Printed: 06-24 -2008 Receipt No.: R08 -00443 Payee: HOSPITALITY INTERNATIONAL GROUP ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -043 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/15/2008 Applicant: CHICKEN NOW Issue Date: Initials: WER Payment Date: 02/15/2008 11:00 AM User ID: 1655 Balance: $224.50 TRANSACTION LIST: Type Method Description Amount Payment Check 2537 46.75 Account Code Current Pmts 000/345.830 46.75 Total: $46.75 • Payment Amount: $46.75 $672 02/15 9710 TOTAL 975.80 3-op doc: Receiot -06 Printed: 02 -15 -2008 Project: C��C ��// /I OC.J AJ Type of Inspection: ,, a l fr/ dl \\ j Addres liad i/ / Date Called: Instructions: Date Wanted: �s 74 5/0 v a.m. P.m. Requester: Phone No: y INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION !' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. Corrections required prior to approval. $60 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be p at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. COMMENTS: 0.4 c6yi le.-/:e Inspector: J 'Date: #7/ Receipt No.: 'Date: COMMENTS: Type of Inspections � � I, A.40 0 1 oIc ,., ' p » " S.. 514,1... - o/C . A, o,'1 S i," ' — ", - f'h 4si fl ys oh / , NAkap 54a) au... Date Wanted: 7 " cis, cam p.m. Requester: Phone No: Project: CIS..(t'H AOc Type of Inspections � � I, Address: 2400 FL 11 Date Called: Special Instructions: Date Wanted: 7 " cis, cam p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f Hof -ow3 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ❑ Approved per applicable codes. Corrections required prior to approval. 'Inspector: (Date: 22- El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: • Project: . Ck.Gw h 1) o.J Type Type of Inspection: ,5*1014.1_ S °vv Address: c C t' Date Called: Special Instructions: ' Date Wanted: 1 is joir a.m. p.m. Phone No: (O7-•- 1.1.10 - CoSto n F INSPECTION NO. .. INSPECTION RECORD Retain a copy with permit AA • 0'13 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 K Approved per applicable codes. Corrections required prior to approval. COMMENTS: dh0 —t . — UMr, i t ��. tSD - Pass. ,( - v e3 AlA —1 tM1 %. eau nspector: 1Date: 1/ ll /a p• ❑ $60.00 REINSPECTION FEE REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: COMMENTS: /. AL ?hs..5 LV pot44i/ 2. S mike Skj CAD c <1 ,�45 T m ks T ,A e C / 7 � t t �[ Date Called: Special Instructions: Date Wanted: / / a. Requester: Phone No 74 9 Project 1 , 14 I A/d� Type of Inspection_,. e d f. n Address� � t t �[ Date Called: Special Instructions: Date Wanted: / / a. Requester: Phone No 74 9 92 f /5 All INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION W- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 3670 Approved per applicable codes. Inspector: g Corrections required prior to approval. Date: 2/ J7 4, j 7 0 $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid 6 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: �'i ketiftEgia COMMENTS: Type of Inspection: gtkili ;n MA Address: 24 00 IltN Fc - 11 Date Called: A c"i S!, 2..r. , C 5l 7-- l4-1w C u Sy ST+ , tz l r. OA- G- r n A i- , .a 4- j":>:04,1 1 ...)( 4 fro 5 e 5.tL IA, . ,4- r" Project: C /1 iCkert Nome Type of Inspection: gtkili ;n MA Address: 24 00 IltN Fc - 11 Date Called: Special Instructions: Date Wanted: 7- /3' Or a.m. P.m. Requester: !9An Phone No: 624 2./6 054 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 J Approved per applicable codes. INSPECTION RECORD Retain a copy with permit 11 PERMIT NO. (206)431 -3670 Corrections required prior to approval. Inspector: (Date: 2 f 5 2 & ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: COMMENTS: Type of Inspect / iio : j( • . Yr t Y t Address: D6 Suite #: s . c . n.4 A-L /._. -I=( - t1 Contact Person: Special Instructions: . (Coy L icl —rRA c. k 0 w k t 00 /, I-0 -et-4 s tAr-c__ t Phone No.: l/h . % c, ve -Liu./ Q. d TO A- ° s APpfLve ,� L..oc .¢f 0 ►✓. P -c.2 rb _T� 6G (- 2- 5/1, e l) (9y,i :I)-ee P r a w JJ , 5f 6K Fl ` - C K fig ttk - 0 r. / Project: O ,' , k e r..1 Al 0,_) Type of Inspect / iio : j( • . Yr t Y t Address: D6 Suite #: s . c . n.4 A-L /._. -I=( - t1 Contact Person: Special Instructions: Permits: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: \ Pre -Fire: Permits: \ Occupancy Type: INSPECTION NUMBER n Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT Word /Inspection Record Form.Doc 1/13/06 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 . required prior to approval. Inspector: 6A.5- Date: 7/9; ( Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING & INSPECTION July 21, 2008 KA No. 066 -08170 die! fl v ED Permit No. M08 -043 JUL 2 5 2000 uv 1d�� Mr. Rat ! li N NT Sound Heating & Air Conditioning 5526 184th St E., Suite A Puyallup, WA 98375 RE: Special Inspection Chicken Now Tukwila, WA Dear Mr. Hood, 21Z211T1 & ASSOCIATES, INC. In accordance with your request and authorization, our firm performed special inspections for the above - referenced project. The inspections were performed by our inspectors from June 24 through July 8, 2008. Copies of our inspector's field reports are attached. Unless otherwise indicated, the structural activities noted on the attached daily field reports were in accordance with the approved project plans and specifications. A guarantee that the contractor has necessarily constructed the structure in full accord with the plans and specifications is neither intended nor implied. If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office at (253) 939 -2500. Respectfully submitted, KRAZAN & ASSOCIATES, INC Kathryn E. Gordon Project Manager Puyallup Division CC: City of Tukwila Offices Serving The Western United States 922 Valley Avenue NW Suite 101 • Puyallup, Washington 98371 • (253) 939 -2500 • Fax: (253) 939 -2556 08170 DFR Template azan & Associates, Inc. GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE rfv/0✓ o& PROJECT#:_ 063/740 PROJECT: ell/C/a/kJ /1/014/ LOCATION: c( & -7 if d ®ke e' i 4I* KRAZAN PROJECT MANAGER: / 'FIELD 0 SHOP WELDING ❑ M.T. ❑ P.T. item(s) inspected: eze.gxre ,QC/t Y' /it/✓.oEl�� cfRrAer — 7 740,00' 7"f"/fP ,4'7r� 7 ' � �s /' 'PA/4 S"F ,e'c 3 .9-7- 9' '. , c e ON IC4 7›.9Aprr ›-Ao.v To the best of my knowledge, the abov Superintendent/Representative: WELDING REPORT NO.: 4 7 2 2 CONTRACTOR: U CC , A PERMIT NO' 49 e'ef . " 0 c.3 INSPECTOR: ifel ofnAIVAi fr krea -e ) JURISDICTION: 17"(„(,x( /Gil WEATHER: /Nj/ f 8eireedwa TEMP: 72A !A/1/2e ca /if /ir . re:e$Di O c/A'/Jr Gvyi'A/,/ - ezprzrov� 'Position: F�L- VERITY. HORIZONTAL OyERHE■D ❑ Filler Metal: 'gg-Process: SMAW FLAW GMAW SAW ❑ Other: Weld Type: FILLET C.P. P.P. PLUG0ther:,r' ,-.KJGt/l Veld Size 1/4" 5/16" 3/8" ❑ Other -Codes: AWS AISC TITLE 21 TITLE 24 UBC ASME WAS NOT performed in accordance with the approved plans, specifications, and regulatory requireme# Techni Serving the Western United States This field report indicates our inspector's observation and testing results based on the site condition and contractor's activities. This inform ion is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. Some information on this report has been provide by others on site. Revision 1 Effective Date: 11/15/07 The information provided in this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. K.1'3Z3I1 & Associates, Inc. REPORTNO.: 3321 GEOTECHNICAL ENGINEERING • ENVIRONMENTAL ENGINEERING CONSTRUCTION TESTING AND INSPECTION DATE: 8/6 e5 CONTRACTOR: •v4 1 W6,9T /Ng PROJEC it: ` ei ©cf/ 70 PERMIT NO I m o e9B- ©S& PROJECT: 67/7/1e.steAe / Weil INSPECTOR: IN "r ' /.4 LOCATION, .tur.€ -,f /ArGY./rwceit0 g.4.ev JURISDICTION: 7j i4Z' /C#4 i,4 KRAZAN PROJECT MANAGER: /C WEATHER: /N/ /D£' ey!//faicid TEMP: 7J /FIELD r ❑ SHOP WELDING ❑ M.T. ❑ P.T. item(s) inspected: L ee8/'9re 4c/Cr //Vx'i4 ,r1 Et'72d .grAD8•v /r�40 Atm/ o�'2Yicr . r ' ,Feweep7 Y7z z y 4 /144/1 p /4Tirri - 49A/ °1�' ' ®, 6461o2 eavA/807A94/ Position: FL VEAL HO ILL OVERHEAD ❑ Filler Metal: fk.Process: SMAW FCAW GMAW SAW ❑ Other: g --Wield Type: FILLET C.P. P.P. PLUG ;i_Other: S.f/0#1 3INeld Size 3/� 1/4" 5/16" 3/8" ❑ Other: 'Codes: S AISC TITLE 21 TITLE 24 UBC ASME frfr'at/Y AP4fAlerev 4e9N4 sge:es.drovees Ps,e .2 5e94. � 3 To the best of my knowledge, the abov Superintendent/Representative: Technician: WAS NOT performed in accordance with the approved plans, specifications, and regulatory requirem40. WELDING Serving the Western United States This field report indicates our inspector's observation and testing results based on the site condition and contractor's activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept responsibility for validity of results. Some information on this report has been provided by others on site. Revision 1 Effective Date: 11/15/07 The information provided in this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. DEPARTMENTS: Public Works Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 • • PLAN / SLIP ACTIVITY NUMBER: M08 -043 DATE: 02 -15 -08 PROJECT NAME: CHICKEN NOW SITE ADDRESS: 2600 SOUTHCENTER MALL - FC -11 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: Structural Review Required APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: 511 2iot Fire Prevention Planning Division Li Permit Coordinator DUE DATE: 02 -21 -08 Not Applicable n No further Review Required DATE: u DUE DATE: 03 -20 -08 Not Approved (attach comments) DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SOUNDHA066BM Licensee Name SOUND HEATING & A/C INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601479795 Ind. Ins. Account Id 57759001 Business Type CORPORATION Address 1 5526 184TH STREET E Address 2 City PUYALLUP County PIERCE State WA Zip 98375 Phone 2538753350 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 1/14/1994 Expiration Date 8/15/2009 Suspend Date Separation Date Parent Company Previous License SOUNDHC 112N2 Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #5 CB1C SC2727 08/03/2001 Until Cancelled $6,000.00 07/10/2001 #4 CBIC SC2727 08/14/1999 08/03/2001 $4,000.00 Business Owner Information Name Role Effective Date Expiration Date HOOD, CURTIS C 01/01/1980 HOOD, RANDY A 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SOUNDHA066BM 06/24/2008 VOLTAGE COMPR FLA MCA MOCP 460/3 -60 RLA LRA 15 1600 460 6.4 46 .9 8.9 15 VOLTAGE MCA MOCP CFM 460/3 -60 3 15 1600 1. ALL FEES, LICENSES, PERMITS AND INSPECTIONS REQUIRED BY LOCAL AUTHORITY SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR AS A PART OF THIS CONTRACT. 2. MATERIALS, EQUIPMENT, WORKMANSHIP AND ARRANGEMENT OF WORK INSTALLED BY THE CONTRACTOR SHALL CONFORM TO GOVERNING CODES, ORDINANCES AND REGULATIONS OF CITY, COUNTY AND STATE, AND SHALL BE SUBJECT TO APPROVAL OF ARCHITECT AND OR ENGINEER. 3. DUCTWORK SHALL BE FURNISHED AND INSTALLED IN SIZES AND LAYOUT AS SHOWN. DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEET STEEL OF GAUGES AND WITH CONNECTIONS AND BRACING IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE LATEST EDITION OF SMACNA. 4. SPLITTER OR BALANCING DAMPERS WHERE SHOWN, SHALL BE OF SUFFICIENT GAUGE TO PREVENT BUCKLING OR VIBRATING, AND SHALL BE OPERATED BY A QUADRANT DAMPER ADJUSTER WITH LOCKING FEATURES WHICH WILL HOLD DAMPER SECURELY IN POSITION AT DESIRED SETTING. 5. DUCT CONNECTIONS TO EQUIPMENT SHALL BE MADE THROUGH AIRTIGHT CANVAS OR OTHER APPROVED FLEXIBLE CONNECTIONS. 6. SHEET METAL DUCTS SHALL BE INSULATED WITH MINIMUM 1 -1/2 INCH THICK FIBERGLASS FACED DUCT WRAP BY OWENS CORNING, OR APPROVED EQUAL, HAVING AN 'R' VALUE OF 6.0 AND FACTORY APPLIED FOIL FACING AND ONE 2 INCH FLANGE. INSULATION SHALL BE INSTALLED ACCORDING TO MFR'S. RECOMMENDATIONS. INSULATION AND VAPOR BARRIER SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPMENT RATING OF 50. 7. REGISTERS, DIFFUSERS AND GRILLES SHALL BE PROVIDED IN SIZES AND LOCATIONS AS SHOWN ON DRAWINGS. CEILING & WALL MOUNTED REGISTERS, DIFFUSERS AND GRILLES SHALL BE EQUIPPED WITH GASKETS BEHIND FACE FLANGES, WHICH SHALL MAKE AN AIRTIGHT SEAL BETWEEN OUTLET AND FACE OF WALL OR CEILING. OUTLETS SHALL BE INSTALLED PLUMB, LEVEL AND PARALLEL TO BUILDING, WALLS OR FLOORS. SUPPLY DIFFUSERS SHALL BE 111 US -PAS, OR OR APPROVED EQUAL, WITH PERFORATED PANEL SIZED AS SHOWN ON DRWG.'S AND WITH DEMOUNTABLE FACES WITH PATTERN CONTROLLERS OF STEEL CONST. WITH WHITE FINISH. RETURN AND EXHAUST REGISTERS SHALL BE TITUS 50 -F5 OR APPROVED EQUAL, ALUMINUM CONSTRUCTION WITH 1/2 x 1/2 x 1/2 INCH GRID AND OPPOSED BLADE BALANCING DAMPER. FINISH TO BE WHITE. 8. PROVIDE CERTIFIED TEST AND BALANCE OF HVAC SYSTEM (AND EXHAUST SYSTEM WHERE APPLICABLE) BY L.L. APPROVED CONTRACTOR, NO LATER THAN THIRTY (30) DAYS AFTER SYSTEM IS INSTALLED TO ARCHITECT FOR APPROVAL BY LANDLORD. 9. THE USE OF FLEXIBLE DUCTS AT DIFFUSERS IS REQUIRED. FLEXIBLE DUCTS SHALL NOT EXCEED 5' IN LENGTH & MAY BE USED AS THE FINAL CONNECTION ONLY. 10. MAXIMUM CONTROL SYSTEM WIRING VOLTAGE SHALL BE TWENTY FOUR (24) VOLTS AND ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND LANDLORD CRITERIA. 11. UNLESS SPECIFICALLY NOTED IN THE ARCHITECTURAL OR MECH. DRAWINGS, ALL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE WITHIN THE PREMISES. ALL DUCTWORK, EQUIPMENT AND OTHER ACCESSORIES IN PUBLIC OR SALES AREAS SHALL BE CONCEALED. 12. PRIOR TO OPENING THE PREMISES FOR BUSINESS, TENANT SHALL PROVIDE L.L. W/ WRITTEN VERIFICATION FROM AN AUTHORIZED REPRESENTATIVE OF TENANTS H.V.A.C. EQUIP. THAT TENANTS NEW H.V.A.C. EQUIPMENT IS INSTALLED AND OPERATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 13. ALL H.V.A.0 EQUIPMENT & DUCTS SHALL BE PROVIDED WITH VIBRATION ISOLATORS, SOUND TRAPS, DUCT LINING, ACOUSTICAL HOUSINGS, ACOUSTICAL LOUVERS ETC. 14. A/C UNIT INSTALLATION SHALL COMPLY WITH THE MFG. SPECIFICATIONS, LANDLORD CRITERIA, MECJANICAL CODES AND CLEARANCE REQUIREMENT FOR SERVICING. 15. REINFORCE ROOF OPENING WITH 3 "X3 "X1/4" STEEL ANGLE AS PER TPICAL STRUCTURE FRAMING PLAN OR AS DIRECTED BY LANDLORD. H000 IDUCIWORK NOTES: SLIDE BE FABRICATED AND INSTALLED PER NFPD 96 AND BUILDING DEPT. REQUERMENTS OVERHEAD CANOPY TYPE HOODS SHALL BE SIZED TO COMPLETELY COVER ALL GREASE EXHAUSTING EQUIPMENT PLUS AT LEAST 6" FROM COOKING SURFACES. DUCT SYSTEMS SHALL NOT BE INTERCONNECTED WITH ANY OTHER BUILDING VENT- ILATION OR EXHAUST SYSTEMS NOR SHALL THEY PASS THROUGH FIRE WALL UNLESS EXPRESSLY NOTED IN THESE PLANS OR AS DIRECTED BY BUILDING REPRESENTATIVE (LANDLORD). ALL DUCTS SHALL BE INSTALLED WITH OUT FORMING DIPS OR TRAPS WHICH MIGHT COLLECT RESIDUE. A RESIDUE TRAP SHALL BE PROVIDED AT THE BASE OF EACH VERTICAL RISER. OPENINGS LARGE ENOUGH TO PERMIT CLEANING SHALL BE PROVIDED AT EACH CHANGE OF DIRECTION OF THE DUCT. METAL DUCTS SHALL BE FABRICATED FROM A MINIMUM 16 GAUGE BLACK STEEL AND MUST BE ASSEMBLED WITH LIQUID -TIGHT WELDED JOINTS. CLEARANCE FROM THE DUCT TO THE INTERIOR SURFACE OF ANY ENCLOSURE OF COMBUSTIBLE MATERIAL SHALL BE NOT BE LESS THAN 18 ", AND CLEARANCE FROM THE DUCT TO THE INTERIOR OF ANY ENCLOSURE OF NON - COMBUSTIBLE MATERIAL SHALL NOT BE LESS THAN 6 ". • ANY OPENINGS IN AN ENCLOSURE WALL SHALL BE PROTECTED BY A SELF - CLOSING DOOR OF PROPER RATING ACCORDING TO NFPA 80. . CONTRACTOR SHALL PROVIDE DUCTCLEAN OUT ACCESS DOORS AT NOT MORE THAN 12' -0" O.C. AND AT EVERY CHANGE IN DIRECTION AS PER NFPA -96. 10. REINFORCE ROOF OPENING WITH 3 "X3 "X1/4" STEEL ANGLE AS PER TPICAL STRUCTURE FRAMING PLAN OR AS DIRECTED BY LANDLORD. SPIN -IN FITTING WITH VOLUME EXTRACTOR AND BALANCING DAMPER HARD DUCT HORIZONTAL HARD ELBOWS WHERE BEND EXCEEDS 45° DUCT CLAMP nu DtJCr tNSTL D ETAJL SCALE: NONE V,C SPECIFICATIONS: NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS FAB AND MASTIC. DUCT CLAMP WRAPPED SHEETMETAL DUCT SEE NOTE #6 IN GENERAL HAVC. SPECS. INSULATED FLEXIBLE DUCT 1 -1/2" INSULATION WITH VAPOR BARRIER COVERING TOP SIDE OF DIFFUSER FROM NECK TO CEILING AND SEALED TO DUCT INSULATION. (R =6.0) NYIP®RTANT INS TO CONTRACTOR ,ANID SUB CONTRACTOR ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR. GENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL EXHIBITS. MARK 0 CD • OA CD RRC RTU EQUIPMENT AHU-1 CU -1 SYMBOL SUPPLY DIFFUSER RETURN AIR GRILLE MAX. 20° TRANSITION 0.25 D (4" MIN. PER SMACNA) RECTANGULAR DUCT VOLUME DAMPER OVA BRANCH DUCT D. LS COOKING EXHAUST SYSTEM CONICAL FITTING WITH LOCKING TYPE VOLUME DAMPER. OR SIDE WALL TAKEOFF EQUAL TO FLEXMASTER STO. SEE SPLIT SYSTEM SCHEDULE FLEX DUCT OR ROUND SHEET METAL DUCT. FLEX DUCT MAX. 5' -0" LONG, USE CLAMP TO ATTACH FLEX DUCTS AND SEAL. SUPPORT DUCT EVERY FOUR FEET FROM STRUCTURE HAM MONO DESCRIPTION/ ACCESSORIES 400 CFM 24X24 W/ 10" ROUND COLLAR W/ OPPOSED BLADE DAMPER, 1/2 "X1/2 "X1 /2" CUBE CORE CONSTRUCTION (EGG CRATE) SEE 'CAPTIVE AIR.' SHOP DRAWINGS (H- SHEETS) FOR SPECIFICATIONS ON HOOD & FAN EQUIP. TITUS OR EQUAL TMS TITUS MODEL #50F 'CAPTIVE' AIR TECH EXHAUST SYSTEMS ITEM AHU-1 1600 EF -1 SF -1 TOTAL INSTALL PER MANUFACTURES PRODUCT LITERATURE. "PRODUCT DATA" DESCRIPTION MANUFACTURER/ MODEL RAM Mg SCALE: N.T.S. AIR BALANCE SCHEIDOLE SUPPLY OUTSIDE RETURN AIR [ AIR g AIR NOTES PLENUM RETURN 300 1300 3400 2 HOUR RATED ASSEMBLY. 1 EXHAUST PRESSURE AIR 4300 4300 300 -4300 3400 -600 * * TO BE DRAWN FROM MALL COMMON AREA TO CREAT NEGATIVE PRESSURE NOTE: PROVIDE SIMILAR CONSTRUCTION AROUND HOOD a a (4) SIDES 0 "GREASE GUARD" GREASE CAPTURE SYSTEM 3" MINIMUM OVERLAP (TYP = LONGITUDINAL 7 ..............„.....„--- OR TRANSVERSE JOINTS) 1 -1/2" 3M FIREMASTER FP DUCT WRAP 1 LAYER = 2 HOUR 16 GA. GREASE DUCT CONT. WELD GALV. CURB IU . 10.1111111111111111111111111 GREASE COLLECTOR ' { I f �l (5) #10 TEK SCREWS ROOF PROTECTION & FAN TM DOWN DETAIL & smuctusm. SUPPORT SCALE: NONE 3 1 CLEARAteE NFPA 96 FAN DISCONNECT, FACTORY WIRED TO MOTOR. VENTILATED CURB ' LIQUID TIGHT FLEXIBLE CONOU1T BYE'. r FLASHING BY GEN. CONTR., COUNTER FLASHING BY MECH. CONTR. CAULK WEATHER TIGHT. EXISTING JOIST 3/1V/ 2 ROOF DECK GREASE DUCT. FLARE TOP TO FIT CURB OPENING. L 3x3x1/4 TWO SIDE OF FAN CURB (4) 1/4" 0 BOLTS (4) SIDES OF CURB L 3 "X3"X1/4" STEEL ANGLE TWO SIDES OF CURB NOTE: 1. PROVIDE CURB EXTENSION OF HEIGHT TO RAISE FAN DISCHARGE HEIGHT TO MIN. 2. OF Z' -0" ABOVE ANY O/A INTAKE WITHIN 10' -0 ". 3. A ROOF PROTECTION SYSTEM SHALL BE PROVIDED AND INSTALLED FOR ALL KITCHEN EXHAUST SYSTEMS BY MECHANICAL CONTRACTOR. MINIMUM METAL GREASE CONTAINMENT BASIN SIZE SHALL BE CALCULATED BY MULTIPLYING THE SIZE OF THE ROOF CURB BY A FACTOR OF (TWO) 2 AND ROUNDING UP TO THE NEAREST ONE (1) FOOT INTERVAL. MINIMUM SIZE SHALL NOT BE LESS THAN 48 "x48 ". , a ALL SUPPLY AND RETURN AIR GRILLES IN FRONT AREA SHALL BE PAINTED TO MATCH CEILING COLOR. ALL TENANT ROOF EQUIPMENT SHALL BE LABLED WITH TENAN'T NAME AND SPACE NUMBER. NEW DUCTWORK, PIPING, OR EQUIPMENT FLEXIBLE DUCT SUPPLY OR OUTSIDE AIR DUCT SECTION RETURN OR EXHAUST DUCT SECTION DUCTWORK TRANSITION MANUAL AIR VOLUME CONTROL DAMPER NEW FIRE DAMPER SUPPLY AIR DEVICE. CLEAR TRIANGLE SIDES INDICATE AIR FLOW PATTERN RETURN OR EXHAUST AIR DEVICE MECHANICAL NOTE - NUMBER MOTORIZED DAMPER WALL MOUNTED THERMOSTAT SMOKE DETECTOR CONDENSATE DRAIN OUTSIDE AIR CEILING DIFFUSER RETURN REGISTER AT CEILING ROOF TOP AIR CONDITIONING UNIT MECLIANKAL MIME SCHEDULE HORIZ. LEG OF 4 "x4 "x 1/4" STEEL ANGLE TO BE PLACED BETWEEN TOP CHORD OF JOIST AND METAL DECK. SEPARATE PEFNIT REWIRED 0 Mechanical l Elechical Vi U Gas Piping City ot 1u 1a BUILDING DIVISION ROOF TRUSS SCALE: NONE 4 "X4 "X 1/4" STEEL ANGLE 3 "X3 "X1 /4" STEEL ANGLE 5/8" DIA. HOLES IN BTM. LEG AS REQ'D TO HANG HOOD USE 1/2" DIA. THREADED ROD HVAC LOAD BASIS OF DESIGN: HEATING LOAD: ROOF OUTSIDE AIR COOLING LOAD: ROOF LIGHTING PEOPLE OUTSIDE AIR SYMBOL/NAME LATENT LOAD: SUMMER WINTER GAS GRIDDLE (74 (4) 17 HEAT LAMP SANDWICH COOLER (2) 40 WATER HTR. 0SFx45 °x0.05 300 CFM x 45° x 1.085 0 SF x 7° x 0.05 2000 W X 3.413 5 x 250 300 x 7° x 1.085 TIONS OUTSIDE INSIDE 82° Fdb, 66° Fwb 75° Fdb, 50% RH 27° Fdb, 72° Fdb TOTAL HEATING LOAD SUB TOTAL SUB TOTAL SUB TOTAL FROM ABOVE .... TOTAL POTENTIAL SENSIBLE COOLING LOAD EQUIPMENT SENSIBLE LOAD x 0.25 PEOPLE 5 PEOPLE x 250 OUTSIDE AIR 300 X 44 GR X 0.68 LATENT TOTAL GRAND TOTAL COOLING LOAD SEE G 'S• S�O DW = 0 BTUH = 14,647 BTUH = 14,647 BTUH 0 BTUH • 6,826 BTUH • 1,250 BTUH 2,278 BTUH = 10,354 BTUH USAGE RADIATION INPUT RATE FACTOR BTU /H 132,000 BTU 1.0 0.033 660,000 BTU 1.0 0.033 1100 w 1.0 0.25 2300 W 0.5 0.10 18 KW 0.1 0.02 2,970 19,800 939 25,610 10,354 BTUH = 35,964 BTUH • 6,402 BTUH • 1,250 BTUH • 1,428 BTUH = 9,080 BTUH 45,044 BTUH 4 TON - ::; s ..' 1 ` ii NOTE: .J,...."!_r 11.1l, jz- . .. •.a pi an 2;.' 'ntta � . � `!' r �.. �Y•� � - rM1' � ' r �c11 f 4i��ti I �:�J�!'P *�r�.iL1 i�.:� }GGJ .r1t G�. UPPER FLOOR TRUSS AT ± 6' -0" D.C. 4 "X4 "X1/4" STEEL ANGLE 3 "X3 "X1/4" STEEL ANGLE SUPPORTS FOR HOOD 1/2"0 THREADED ROD HOOD HANGERS 392 123 PROVIDE HANGER RODS AND SUPPORT FROM BUILDING STRUCTURE FOR AHU SUITABLE ANGLE IRON SUPPORT (IF REQUIRED) Plar APP the vi of ap 7. . HVAC oticr PLAN SCALE: 1/4" = 1' -0" CU -1 ermit No. V _. _ _..� 2. .... - 1 . .::.-- .J ... .__- ............ .......................•_•_.... AHU -1 Date: __& r) -• -( City of Tukwila LENNOX# HS 29 - 048-3G 460/3 -60 191 LB. LENNOX# CB 29 M 51 -1G 460/3 -60 181 LB. BUILDING DIVISION MR HANDLING UNIT MOUNTING DETAIL NO SCALE W /ELECTRICAL HTR. #ECB29 -8 (28K42) 208 VOLT FILE y � � If 24 MCA 25 MOCP ew approval 1S sI ct to errors and orn!SSions. Val of constructkm documents does not atdhorize cation of any adopted code or onfinance. Receipt roved ' l 3, • • and '- • • • .: acknowledged: 4(0 E 26X20 3400 CFM DOWN FROM SF -1 ON ROOF THRU LANDLORD PROVIDED HVAC SHAFT SPA SY 1114, SCHEDULE 10.0 EER 1600 CFM PROVIDE SEPARATE SUPPORT FOR SECONDARY PAN SPRING TYPE VIBRATION ISOLATORS FLEX BY MANUFACTURER CONN. RETURN AIR DUCT (I`M'P) SEE FLOOR PLAN W� 1 FOR DUCT SIZE REFER TO FLOOR PLAN SECONDARY DRAIN PAN TO BE 3" DEEP AND 6" LARGER THAN AHU ON ALL FOUR SIDES. PRIMARY CONDENSATE DRAIN LINE NOTE: PROVIDE FLOAT SWITCH IN SECONDARY PAN; INTERLOCK WITH UNIT FAN MOTOR FOR SHUTDOWN UPON DETECTION OF WATER IN PAN 400 CFM 10' 0 2 5 30 50 •2'60 CF 10X28 3/4" 1 " PROVIDE PLUG FOR MAINTENANCE CONDENSATE MAX. TONS PIPE SIZE 1 1/4" 1 1/2" 6X12 4 18X1 UP TO THRU HVA Flz- DL7Cl EF4 ON ROOF LANDLORD PROVIDED SHAFT REQUIRED 10' -O" MINIMUM SEPERATXON BETWEEN EXHAUST FAN AND AIR - INTAKES MUST ALSO CONSIDER ADJACENT TENANT'S ROOF EQUIPMENT, MECH. DUC P!`A'i N NOTES: O 3" DEEP GALV. AUX. DRAIN PAN DRAIN TO F.S. IN KITCHEN SEE P -1 a 12"0 (300 CFM) O.A. DUCT THRU ROOF TO GRAVITY VENTILATION (JENN FAN RV SERIES OR EQ.) THRU L.L. PROVIDED SHAFT. 1" I.D. DRAIN LINE TO F.S. IN KITCHEN INSULATED REFRIGERATION LINES TO CONDENSING UNIT ON ROOF 16 G.A GALV. MIXING BOX W /FILTER PROVIDE CLEANOUT AT EACH CHANGE OF DIRECTION OR EVERY 30' F 900 CFM 10X20 10 "0 DRAIN LINE. A SLOPE WITH FLOW r1 /8 " /FT TO A DRAIN OR OUTSIDE A = FAN PRESSURE + 1 INCH CONDENSATE DRAIN TRAP DETAIL NO SCALE (FOR DRAW THRU APPLICATIONS) R ; ;mod MO8oM3 FEB 15 2008 PE iit?e CbNTEh DATE: 12 -24 -07 JOB NO: 0734 DRAWN: CHECKED: REVISIONS A REVISED PER LANDLORD 1/23/08 DAVID HIATT ARCHITECT 4410 W. Melrose Avenue Tampa, Florida 33629 p. 813.289.3336 f. 813.289.3332 REGISTERED ARCHITECT DAVID W. HIA1T STATE OF WASHINGTON MECHANICAL PLAN, NOTES & DETAILS SHEET NUMBER NO SCALE 3/8" MACHINE BOLT TWO U -BOLT CLAM PER CONNECTION. CABLE RUN AT 45'. (!) w 1 "WX2 "LX 12 GA. STEEL CONC. OR WALL PIPE SIZE VARIES wow / 6105.22 �el 10 1 STEEL JOIST STEEL BEAM CLAMP SPACER /2" A.T.R. 24" MAX. LENGTH TWO EACH 1/4" SUPPORT CABLES FORMING A 90' ANGLE (BOTH SIDES OF HANGER) f PIPE HANGER RING PIPE 1 "WX2 "LX 12 GA. STEEL GAS PIPE HANGER DETAIL NO SCALE NOTES: VERTICAL HANGERS AT SHALL BE SPACED AS FOLLOWS: 1-1/4" AND LARGER 10' O.C. 1" AND SMALLER PIPE - 8' O.C. PROVIDE BRACING AT ENDS OF PIPE AND AT A MINIMUM OF 40' O.C. PROVIDE A MINIMUM OF ONE BRACE ASSEMBLY AT EACH CHANGE OF DIRECTION. PHILLIPS MASONRY ANCHOR AND CAP SCREW 1 MIME GRINNELL, 0/E f FIG. 202 SIDE BEAM BRACKET THREADED ROD GRINNELL, 0/E FIG. 260 ADJUSTABLE WROUGHT CLEVIS pM • 90' WALL $®t ,ANCI4OR WITH CtEVIS HANGER I 5/8" EXPANSION ANCHOR BOLT 9 EXTERIOR WALL PIPE HANGER DIETAJL NO SCALE (EARTHQUAKE BRACE - STEEL) 12 GAGE HANGER WIRE TYP. (VERT. & SWAY BRACE) VERT. WIRES CO 6' -O" O.C. STEEL JOIST 1/4" SUPPORT CABLE TWO U -BOLT CLAMPS PER CONNECTION CABLE RUN AT 45'. BRACE CONNECTION AT STRUCTURE NO SCALE ---� �- GAS PIPE DUCT WALL A5 To . PLAN STRUT CHANNEL 12 GA. MIN. 1/2" STUD NUT WITH SPRING (TYP-2) FRONT VIEW VERTICAIL GAS PIPE SUPP0RT DETAIL NO SCALE NOTE: INSTALL SUPPORT AT TOP AND BOTTOM OF RISER. J O a co 3/8" BOLT AND NUT TO STEEL JOIST EXTERIOR WALL 'TYPICAL DUCT SUPPORT DETAKS SCALE: NONE GAS PIPE SIDE VIEW 1/8 "X1 -5/8" WIDE STANDARD PIPE CLAMP 1/2" STUD NUT WITH SPRING (m' -2 ) r (E ) CONC. TOPPING OVER MTL. DECK SECTION \ DUCT 1 MIN 3.8 0 ANL_ Me. AIL - 0.14 "SHANK DIAM. PENETRATION TYP. — CEILING CLIP TYP. 12 CA. HANGER WIRE 12 GAGE VERT. HANGER WIRES ® 6' -0" O.C. CLIP L2x2x12 GA. x 0' -4" LONG W/2 - #10 SELF DRILLING, SELF TOPPING METAL SCREWS © 2" O.C. TO DUCT. 3400 CFM SF-1 NOT TO SCALE 4 ROOF KAN 4300 FM EF -1 F -1 m 8X18 LANDLORD PROVIDE MECH. SHAFT FEB 15 2008 PEHir{f 9 CENT &s DATE: 12-24-07 JOB NO: 0734 DRAWN: CHECKED: DAVID MATT ARCHITECT 4410 W. Melrose Avenue Tampa, Florida 33629 p. 813.289.3336 f. 813.289.3332 REVISIONS REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON ROOF PLAN, NOTES & DETAILS SHEET NUMBER M,-2 HOOD ND. FILTER(S) LIGHT(S) GENERAL NOTES I f 1, ELECTRICAL HOOK -UP TO CAS MOTOR CONTROLS • • • O ® 24' 24' C 1 Hood #1 r WIRE N& / 2, FIRE CHASE BY OTHERS, IF REQUIRED. I f// /. 3. ALL PHASES OF INSTALLATION SHALL COMPLY SIZE MODEL # WITH NFPA 96. LOCATION \ \ � a 1 14 16' / 8 14' L 3,000 3 20 1---14'----1 l.� r�l 14 • 1 n 1 1 o 1 YES 614 LBS. 6. EXHAUST DUCT TO BE 16 GA, GAV STEEL • 0 U.L. Listed Incandescent Light Fix 1 10' = 0 _ IBM I IBM L . 10 - - -- 1 8' — fli — g' L JJ— � r�C� 1 II�II_ Ilall + 1 HOOD ND. FILTER(S) LIGHT(S) GENERAL NOTES FIRE SYSTEM PIPING 1, ELECTRICAL HOOK -UP TO CAS MOTOR CONTROLS TYPE QTY. (MOTOR STARTERS, FAN SWITCHES. LENGTH QTY. FAN DISCONNECTS, RELAYS, ETC.) BY OTHERS. WIRE N& LOCATION 2, FIRE CHASE BY OTHERS, IF REQUIRED. ELECTRICAL SWITCHES 3. ALL PHASES OF INSTALLATION SHALL COMPLY SIZE MODEL # WITH NFPA 96. LOCATION 1 4. WRITTEN MEASUREMENTS HAVE PRECEDENCE 6 16' OVER SCALE. 8 Incandescent Light Fix 5. PROVIDE CLEANDUTS IN EXHAUST AIR 3,000 3 DUCTS AS INDICATED TO ALLOW CLEANING 9,5 G15 AT ALL BENDS AND HORIZONTAL RUNS. YES 614 LBS. 6. EXHAUST DUCT TO BE 16 GA, GAV STEEL 16' 20' ALL SEAMS AND JOINTS TO HAVE A LIQUID 208 9.5 TIGHT CONTINUOUS EXTERNAL WELD. 2150 7. FAN TO HAVE A MINIMUM OF 10 FT, OF 10' 28' CLEARANCE FROM THE OUTLET TD ADJACENT 1250 0.202' BUILDINGS, PROPERTY LINES, AIR INTAKES OR 3 FT, VERTICAL CLEARANCE PER NFPA96 0. HORIZONTAL EXHAUST DUCT TO SLOPE NOT LESS THAN 1/4' PER FOOT TOWARD HOOD FOR DUCT LESS THAN 75' LONG, 1' PER FORT SLOPE FOR DUCT LONGER THAN 75' 9. HOOD TO OVERHANG COOKING EQUIPMENT 6' ON ALL OPEN SIDES. 10. EXHAUST DUCT TD BE PROTECTED FRUM COMBUSTIBLES PER NFPA96 AND LOCAL CODE. 11. BUILDING PRESSURE SHALL NOT EXCEED D. 02' WATER COLUMN AT EXTERIOR DOORS, 12. KITCHEN SHALL BE BALANCED TO BE NEGATIVE WITH RESPECT TO THE DINING ROOM. HOOD ND. FILTER(S) LIGHT(S) UTILITY CABINET(S) FIRE SYSTEM PIPING HOOD WEIGHT TYPE QTY. HEIGHT LENGTH QTY. TYPE WIRE N& LOCATION FIRE SYSTEM ELECTRICAL SWITCHES TYPE SIZE MODEL # QUANTITY LOCATION 1 SS Baffle with Handles 6 16' 16' 8 Incandescent Light Fix NO 3,000 3 208 9,5 G15 A2 -11500 YES 614 LBS. 8 16' 20' FAN UNIT NO. FAN UNIT MODEL # EXHAUST FAN SUPPLY FAN MODEL TAG CFM S.P. RPM HP. 0 VOLT FLA BLOWER HOUSING TAG CFM S.P. RPM H.P. 0 VOLT FLA 1 NCA24HPFA KEF--1 NCA24HPFA 10' 10.00' 4300 - 1500' 1000 3,000 3 208 9,5 G15 A2 -11500 28' 3400 0.600' B93 3,000 3 208 9.5 FAN UNIT NO, FAN UNIT MODEL # EXHAUST FAN SUPPLY FAN MODEL TAG CFM S.P. RPM H.P. 0 VOLT FLA BLOWER HOUSING TAG CFM S,P, RPM H.P. 0 VOLT FLA 2 A2- D.500 -G15 KSF -1 4824 NDI- PSP -FS 10' 10.00' 400 Deg. 4300 14' 14' 53 -5/8 2150 -0.442 G15 A2 -11500 28' 3400 0.600' B93 3,000 3 208 9.5 HOOD ND MODEL LENGTH MAX. COOKING TEMP. EXHAUST PLENUM SUPPLY PLENUM HOOD CONSTRUCTION HOOD CDNFIG. TOTAL EXH. CFM RISER(S) TOTAL SUP. CFM RISER(S) END TO END ROW WIDTH LENG. DIA. CFM S.P. WIDTH LENG, DIA. CFM SP, 1 4824 NDI- PSP -FS 10' 10.00' 400 Deg. 4300 14' 14' 53 -5/8 2150 -0.442 3400 10' 28' 16 6 -1/8 10 - 13/16 1250 0.202' 430 SS Where Exposed ALONE N/A 14' 14' 2150 -0.442 10' 28' 1250 0.202' 'C' BTU RANGE (MBH) GAS PRESSURE BLOWER/ MOTOR ACCESS DOOR CFM RANGE FILTER SIZE & QTY ➢IM 'T' DIRECT FIRED o MODULE MODEL BURNER LENGTH BTU LOW BTU HIGH MIN MAX 'T' OPT) MIN MAX D.500 - G15 12' 18 550 FAN MODEL BTU RANGE (MBH) GAS PRESSURE GAS CONNECTION CFM RANGE FILTER SIZE & QTY MAX. FILTER VEL ❑CITY MODEL BURNER LENGTH BTU LOW BTU HIGH MIN MAX 'T' OPT) MIN MAX D.500 - G15 12' 18 550 7' WC 14' WC 1 2500 6000 20'x25'x2' (3) 26000 CFM = 696 FPM FAN MODEL HT W B UNIT DIMENSIONS F R RO WEIGHT LB CURB 37 1/2 DISCHARGE OPENING MODEL WEIGHT A B C ➢ E F G H J K N P R S 0500 -G15 810 LBS 82 -3/8 37 -3/8 36 -3/4 33 -1/16 3 -3/4 53 -5/8 7 - 13/16 42 -13/16 31 79 18 -3/4 16 6 -1/8 10 - 13/16 FAN MODEL HT W B C F R RO WEIGHT LB NCA24HPFA 37 1/2 43 3/8 2 33 30 5/8 23 7/8 28 270 FAN UNIT NO, BTU's TEMP. RISE GAS TYPE 2 245616 70 deg F Natural FAN MODEL D E NCA24HPFA 31 1/2 20 48' 16' L 1 ' — HOOD INFORMATION 32' 28' 66' 10' 10,00' PLAN VIEW — Hood %1 — 10' 10.00' LONG 4824NDI— PSP —FS AIR BALANCE NOTE: TOTAL EXHAUST - HOOD EXHAUST — HOOD SUPPLY TOTAL EXHAUST = 4,300 CFM — 3,400 CFM TOTAL EXHAUST = 900 CFM NEEDED FROM HVAC ELECTRICAL PREWIRE PACKAGE DRAWING NUMBER 31111083 JOB NAME Chicken Now @ Southcenter Mall - SeattfiATE JOB NUMBER 703351 12/19/2007 DRAWN BY CONTROL INPUT 120VAC H1 =UNE, N1= NEUTRAL 15A BKR DO NO1 WIRF TO SHUN' TRIP BREAEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22 23 24 18 INPUT 3 WIRE 3 PHAS 120VAC SHUNT TRIP BREAKER CONTROL WIRING FIELD WIRED BY ELECTRICIAN AS SHOWN UGHT INPUT 120VAC H2 -H5 =UNE, N2 -N5= NEUTRAL 15 15AKR LS-01 OR ME WH R1 -2 LIGHTS OUT IN NC C FIRE CONDITION. 3 PHASE 208V ST -1 OL -1 L1 T1 T1 21 L2 T2 T2 L3 T3 T3 3 3 PHASE 208V ST -2 OL -2 L1 T1 T1 24 L2 T2 T2 L3 T3 73 6 SUP -2 GR GR SHUNT TRIP BREAKER BY OTHERS BK WH 3 Phase, W/ 1 Exhaust Fan, 1 Supply Fan, Exhaust In Fire, Lights out In Fire Label Description ST Starter FS MS R1 LS L GP TX C OR AF Spare Relay Contacts C -RD NO -BL NC -PR j_ NC 3 Fan Switch Lighted MicroSwitch ( Ansul/ roChem) Relay DPDT Light Switch (1400W max) Hood Light(s) General Relay DPDT Transformer Contactor Ground Air Flow Switch MS -1. MS -2 MicroSwitch Ansul Pyrochem C -RD C -RD NO -BK NO -BK NC -BR NC -BR SPARE RELAY CONTACTS 4 NO 6 7 COM 9 CAN BE USED TO CONTROL ITEMS REQUIRING SHUT A COILS DOWN WHEN THE FIRE SYSTEM DISCHARGES, SUCH R1 -R5 AS SHUNT TRIP, SIGNALS, RELAY Soag C Relay Contacts NC R2-1 TERMINAL FOR FIELD C WIRING TD BUILDING FIRE PANEL, DRY CONTACTS FOR SIGNAL ONLY MS -2 NC NOTES. 12 x 18 x 6 Box DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YV - YELLOW BL - BLUE GY - GRAY BR -• BROWN PR - PURPLE DR - ORANGE OR/BL - ORANGE/BLUE RD - RED (STRIPE) WH - WHITE BL /RD - BLUE/RED (STRIPE) RD /GN - RED /GREEN (STRIPE) DRAWING SHOWN OE- ENERGIZED NOTE* IF WALL MOUNT PREWIRE, UR FIELD INSTALLED FIRE SYSTEM MICROSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED, PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) 1 1 . ' 1 ■ 10 11 12 13 14 15 16 17 18 19 20 22 23 28' 10' 20' GR o- 3 4 5 32' 900 0.151' Direct Fired Heater Wiring DRAWING NUMBER DF703351 -2 SW -01 12' 1' 32' 32' -01 BK BK CB ® y Bla a BK TR -01 u »s WH BK BL TS -03 R BK OR No TS -01 C NOo Gam® NCO RD SENSOR 0 - BK D DL -01 95 96 gT �1 PS -01 NO NC BK ST -01 A2- Al JOB NAME Chicken Now @ Sauthcenter Mall - Se JOB NUMBER 703351 PS -02 BK CC DR :6�.. oA S2o _L--9G S19 4 'o B 5 B�® --1?_1 L HK SPARK PLUG 70DR 60 20 3o G blSOGY FSC -01 FR -01 Sri` -03 53 010 � o 2 o 030 TS -05 ST-01 OL Tl BK L T L T3 3 BK MT-02 BK _ 1 . Q 2 TS -02 C NC GY u WH WH TR-02 CY ea BL 0--a a o 0 0 o 0 0 0 VA-01 —4b- VA-03 MT-0 H WH WH WH GR CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 NSF UL 710 & ULC710 STANDARDS E,T,L, LISTED 3054804 -001 iviaRE Wff/19/2007 MODEL A2 0.500 - 015 Installed Options Notarized Back Draft Damper Freeze Stat Maxltrol 14 Discharge Temp. Control C H 01 C Ch.-cult breaker C2anp) [3] FR-01 Flame rod FSC-01 Flreye ESC MA - 01 Maxitrol AD1014 - 4080 MT - Supply motor MT -02 Damper nator UL-01 Supply motor overload PS-01 Low Airflow Switch PS-02 High Airflow Switch E1111 -14] [19] C2] [5] [21[7] [9] [9] ST -01 Supply motor contactor [27[7][9] SW-01 SW -03 TR -01 TR -02 TR-03 TR-04 TS TS TS Main dlscanroct switch [2I Damper end limn switch [4] Power transfornerC200vaI3] Power trahsformer(20va)[12] Ignition transformer [14] Power transformerC2Ova)C171 Freeze slat [4-51 High temp UFO: switch [107 Intake air thermostat [10] TS Maxttral TS14 sensor [211 VA -01 Pilot goS valve [13] VA - 02 Main gas valve t181 VA -03 Modulating gas valve [20] yotor Info Cunnly HP 3 VOLTS 3 Ohs 208 V FLA 9,5 CONTACTOR LC1K1210G7 OVERLOAD LR2K0316 MINIMUM CIRCUIT AMPACITYI 13.03 NOTES DENOTES FIELD WIRING DENOTES INTERNAL WANG +r4 TERMINALS S4 AND 56 USED ON mew A TEP,MINAL 1 PROVIDES COOLING CONNECTION WIRE CI01 UR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN OR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED PK - PINK WM WHITE HANGING ANGLE 16 U.L CLASSIFIED BAFFLE -TYPE GREASE FILTERS EXHAUST RISER SLOPED GREASE DRAIN WITH REMOVABLE CUP SECTION VIEW — MODEL 4824 —NDI with PSP Accessoru PLENUM PROTECTION NOZZLE 48' EQUIPMENT BY OTHERS 33' MIN 48' MAX TYPICAL PYROCHEM SYSTEM LAYOUT fTH REMOTE MOUNTED AUTOMAN 41 : 0■■,. DUCT PROTECTION �� 14 NOZZLE C ►l am -� • Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4.1. DETECTORS 100W VAPORPROOF INCANDESCENT LIGHT ATTACHING ANGLES 1 2,75' SUPPLY RISER WITH VOLUME DAMPER 78' DETECTION LINE REMOTE MANUAL PULL STATION NOM TYP 23.5% OPEN STAINLESS STEEL PERFORATED PANEL 1 *AGENT LINE SYSTEM CONTROL AUTOMAN WITH AGENT TANK ENCLOSED FAN INFORMATION CAHPFA SERIES UPBLAST EXHAUST FANS (UL762) FAN INFORMATION HT UNIT INFORMATI ❑N, B NCAHPFA BELT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA MODULAR OUTDOOR DOWN DISCHARGE DIRECT FIRED HEATER R G =R+3' R❑ C REASE DRAIN DIM 'S' -- I DIM 'F' DIM 'N' DIM 1 DIM 'R' DIM DIM 'G" 2G FEATURES; OPTIONS: GREASE BOX HINGED FAN PITCHED CURB INSULATED CURB DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) r L L _ a CURB OUTER WALL - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TD DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300'F (149•C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300'F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. DIM 'A' DIM 'P' DISCHARGE OPENING FLEX CONDUIT FOR FIELD WIRING SERVICE DISCONNECT SWITCH ROOF OPENING 2' SMALLER THEN CURB DIMENSION, ALL DIMENSI ❑NS ARE NOMINAL AND GIVEN IN INCHES, GAS FIRED MAKE —UP AIR UNIT(S AME El - - 1247E 12 -19 -07 D#rc # 071219CN REV AIRFL ❑W wOmmmm SLOPED FILTER INTAKE R❑ LOCATION SEATTLE, WA PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH* 12 EXAMPLE* 7/12 PITCH = 30' SLOPE CURB DIMENSIONAL DATA DIM 'F' / —LIFTING LUGS - ., :•., F 4 PLACES C (-' ' i_., R❑ 20 IN HIGH rr l + ' ' 2 EQUIPMENT CURB �._.,__..e.._..�.... .. 3' FLANGE 0 0 9 D VENTED CURB 20 GAUGE STEEL CONSTRUCTION ROOF OPENING DIMENSIONS FOR QUESTI ❑NS, CALL THE SOUTHWEST FLORIDA REGIONAL OFFICE 142A WHITAKER RD, LUTZ, FL 33549 PHONE: C813)435 -3388 FAX: [813)354 -4825 CUSTOMER APPROVAL TO MANUFACTURE: Approved as Noted Approved with NO Exception Taken Revise and Resubmit SIGNATURE Your Title Date JOB # 703351 H -1 JOB CHICKEN NOW © SOUTHCENTER MALL DRAiNBY DC SCALE 1/2 In =1 Ft FEB 15 2008 Type PH Volt HP FLA BREAKER I Motor Exh -1 Exh 3 208 3 9.5 30 Amp Sup -2 Sup 3 208 2 9.5 -- Amp 48' 16' L 1 ' — HOOD INFORMATION 32' 28' 66' 10' 10,00' PLAN VIEW — Hood %1 — 10' 10.00' LONG 4824NDI— PSP —FS AIR BALANCE NOTE: TOTAL EXHAUST - HOOD EXHAUST — HOOD SUPPLY TOTAL EXHAUST = 4,300 CFM — 3,400 CFM TOTAL EXHAUST = 900 CFM NEEDED FROM HVAC ELECTRICAL PREWIRE PACKAGE DRAWING NUMBER 31111083 JOB NAME Chicken Now @ Southcenter Mall - SeattfiATE JOB NUMBER 703351 12/19/2007 DRAWN BY CONTROL INPUT 120VAC H1 =UNE, N1= NEUTRAL 15A BKR DO NO1 WIRF TO SHUN' TRIP BREAEL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 19 20 21 22 23 24 18 INPUT 3 WIRE 3 PHAS 120VAC SHUNT TRIP BREAKER CONTROL WIRING FIELD WIRED BY ELECTRICIAN AS SHOWN UGHT INPUT 120VAC H2 -H5 =UNE, N2 -N5= NEUTRAL 15 15AKR LS-01 OR ME WH R1 -2 LIGHTS OUT IN NC C FIRE CONDITION. 3 PHASE 208V ST -1 OL -1 L1 T1 T1 21 L2 T2 T2 L3 T3 T3 3 3 PHASE 208V ST -2 OL -2 L1 T1 T1 24 L2 T2 T2 L3 T3 73 6 SUP -2 GR GR SHUNT TRIP BREAKER BY OTHERS BK WH 3 Phase, W/ 1 Exhaust Fan, 1 Supply Fan, Exhaust In Fire, Lights out In Fire Label Description ST Starter FS MS R1 LS L GP TX C OR AF Spare Relay Contacts C -RD NO -BL NC -PR j_ NC 3 Fan Switch Lighted MicroSwitch ( Ansul/ roChem) Relay DPDT Light Switch (1400W max) Hood Light(s) General Relay DPDT Transformer Contactor Ground Air Flow Switch MS -1. MS -2 MicroSwitch Ansul Pyrochem C -RD C -RD NO -BK NO -BK NC -BR NC -BR SPARE RELAY CONTACTS 4 NO 6 7 COM 9 CAN BE USED TO CONTROL ITEMS REQUIRING SHUT A COILS DOWN WHEN THE FIRE SYSTEM DISCHARGES, SUCH R1 -R5 AS SHUNT TRIP, SIGNALS, RELAY Soag C Relay Contacts NC R2-1 TERMINAL FOR FIELD C WIRING TD BUILDING FIRE PANEL, DRY CONTACTS FOR SIGNAL ONLY MS -2 NC NOTES. 12 x 18 x 6 Box DENOTES FIELD WIRING DENOTES INTERNAL WIRING WIRE COLOR BK - BLACK YV - YELLOW BL - BLUE GY - GRAY BR -• BROWN PR - PURPLE DR - ORANGE OR/BL - ORANGE/BLUE RD - RED (STRIPE) WH - WHITE BL /RD - BLUE/RED (STRIPE) RD /GN - RED /GREEN (STRIPE) DRAWING SHOWN OE- ENERGIZED NOTE* IF WALL MOUNT PREWIRE, UR FIELD INSTALLED FIRE SYSTEM MICROSWITCH, THE TERMINALS SHOWING FACTORY WIRING MUST BE FIELD WIRED, PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) 1 1 . ' 1 ■ 10 11 12 13 14 15 16 17 18 19 20 22 23 28' 10' 20' GR o- 3 4 5 32' 900 0.151' Direct Fired Heater Wiring DRAWING NUMBER DF703351 -2 SW -01 12' 1' 32' 32' -01 BK BK CB ® y Bla a BK TR -01 u »s WH BK BL TS -03 R BK OR No TS -01 C NOo Gam® NCO RD SENSOR 0 - BK D DL -01 95 96 gT �1 PS -01 NO NC BK ST -01 A2- Al JOB NAME Chicken Now @ Sauthcenter Mall - Se JOB NUMBER 703351 PS -02 BK CC DR :6�.. oA S2o _L--9G S19 4 'o B 5 B�® --1?_1 L HK SPARK PLUG 70DR 60 20 3o G blSOGY FSC -01 FR -01 Sri` -03 53 010 � o 2 o 030 TS -05 ST-01 OL Tl BK L T L T3 3 BK MT-02 BK _ 1 . Q 2 TS -02 C NC GY u WH WH TR-02 CY ea BL 0--a a o 0 0 o 0 0 0 VA-01 —4b- VA-03 MT-0 H WH WH WH GR CAPTIVE -AIRE HOODS ARE BUILT IN COMPLIANCE WITH NFPA #96 NSF UL 710 & ULC710 STANDARDS E,T,L, LISTED 3054804 -001 iviaRE Wff/19/2007 MODEL A2 0.500 - 015 Installed Options Notarized Back Draft Damper Freeze Stat Maxltrol 14 Discharge Temp. Control C H 01 C Ch.-cult breaker C2anp) [3] FR-01 Flame rod FSC-01 Flreye ESC MA - 01 Maxitrol AD1014 - 4080 MT - Supply motor MT -02 Damper nator UL-01 Supply motor overload PS-01 Low Airflow Switch PS-02 High Airflow Switch E1111 -14] [19] C2] [5] [21[7] [9] [9] ST -01 Supply motor contactor [27[7][9] SW-01 SW -03 TR -01 TR -02 TR-03 TR-04 TS TS TS Main dlscanroct switch [2I Damper end limn switch [4] Power transfornerC200vaI3] Power trahsformer(20va)[12] Ignition transformer [14] Power transformerC2Ova)C171 Freeze slat [4-51 High temp UFO: switch [107 Intake air thermostat [10] TS Maxttral TS14 sensor [211 VA -01 Pilot goS valve [13] VA - 02 Main gas valve t181 VA -03 Modulating gas valve [20] yotor Info Cunnly HP 3 VOLTS 3 Ohs 208 V FLA 9,5 CONTACTOR LC1K1210G7 OVERLOAD LR2K0316 MINIMUM CIRCUIT AMPACITYI 13.03 NOTES DENOTES FIELD WIRING DENOTES INTERNAL WANG +r4 TERMINALS S4 AND 56 USED ON mew A TEP,MINAL 1 PROVIDES COOLING CONNECTION WIRE CI01 UR BK - BLACK YW - YELLOW BL - BLUE GR - GREEN OR - BROWN GY - GRAY OR - ORANGE PR - PURPLE RD - RED PK - PINK WM WHITE HANGING ANGLE 16 U.L CLASSIFIED BAFFLE -TYPE GREASE FILTERS EXHAUST RISER SLOPED GREASE DRAIN WITH REMOVABLE CUP SECTION VIEW — MODEL 4824 —NDI with PSP Accessoru PLENUM PROTECTION NOZZLE 48' EQUIPMENT BY OTHERS 33' MIN 48' MAX TYPICAL PYROCHEM SYSTEM LAYOUT fTH REMOTE MOUNTED AUTOMAN 41 : 0■■,. DUCT PROTECTION �� 14 NOZZLE C ►l am -� • Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall comply with Sections 401.4 and 401.4.1. DETECTORS 100W VAPORPROOF INCANDESCENT LIGHT ATTACHING ANGLES 1 2,75' SUPPLY RISER WITH VOLUME DAMPER 78' DETECTION LINE REMOTE MANUAL PULL STATION NOM TYP 23.5% OPEN STAINLESS STEEL PERFORATED PANEL 1 *AGENT LINE SYSTEM CONTROL AUTOMAN WITH AGENT TANK ENCLOSED FAN INFORMATION CAHPFA SERIES UPBLAST EXHAUST FANS (UL762) FAN INFORMATION HT UNIT INFORMATI ❑N, B NCAHPFA BELT DRIVE CENTRIFUGAL UP -BLAST EXHAUST FANS DIMENSIONAL DATA MODULAR OUTDOOR DOWN DISCHARGE DIRECT FIRED HEATER R G =R+3' R❑ C REASE DRAIN DIM 'S' -- I DIM 'F' DIM 'N' DIM 1 DIM 'R' DIM DIM 'G" 2G FEATURES; OPTIONS: GREASE BOX HINGED FAN PITCHED CURB INSULATED CURB DUCTWORK BETWEEN EXHAUST RISER ON HOOD AND FAN (BY OTHERS) r L L _ a CURB OUTER WALL - ROOF MOUNTED FANS - RESTAURANT MODEL - UL762 - AMCA SOUND AND AIR CERTIFIED - WIRING FROM MOTOR TD DISCONNECT SWITCH - WEATHERPROOF DISCONNECT - HIGH HEAT OPERATION 300'F (149•C) - GREASE CLASSIFICATION TESTING NORMAL TEMPERATURE TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING AIR AT 300'F (149'C) UNTIL ALL FAN PARTS HAVE REACHED THERMAL EQUILIBRIUM, AND WITHOUT ANY DETERIORATING EFFECTS TO THE FAN WHICH WOULD CAUSE UNSAFE OPERATION. ABNORMAL FLARE-UP TEST EXHAUST FAN MUST OPERATE CONTINUOUSLY WHILE EXHAUSTING BURNING GREASE VAPORS AT 600'F (316'C) FOR A PERIOD OF 15 MINUTES WITHOUT THE FAN BECOMING DAMAGED TO ANY EXTENT THAT COULD CAUSE AN UNSAFE CONDITION. DIM 'A' DIM 'P' DISCHARGE OPENING FLEX CONDUIT FOR FIELD WIRING SERVICE DISCONNECT SWITCH ROOF OPENING 2' SMALLER THEN CURB DIMENSION, ALL DIMENSI ❑NS ARE NOMINAL AND GIVEN IN INCHES, GAS FIRED MAKE —UP AIR UNIT(S AME El - - 1247E 12 -19 -07 D#rc # 071219CN REV AIRFL ❑W wOmmmm SLOPED FILTER INTAKE R❑ LOCATION SEATTLE, WA PITCHED CURBS ARE AVAILABLE FOR PITCHED ROOFS. SPECIFY PITCH* 12 EXAMPLE* 7/12 PITCH = 30' SLOPE CURB DIMENSIONAL DATA DIM 'F' / —LIFTING LUGS - ., :•., F 4 PLACES C (-' ' i_., R❑ 20 IN HIGH rr l + ' ' 2 EQUIPMENT CURB �._.,__..e.._..�.... .. 3' FLANGE 0 0 9 D VENTED CURB 20 GAUGE STEEL CONSTRUCTION ROOF OPENING DIMENSIONS FOR QUESTI ❑NS, CALL THE SOUTHWEST FLORIDA REGIONAL OFFICE 142A WHITAKER RD, LUTZ, FL 33549 PHONE: C813)435 -3388 FAX: [813)354 -4825 CUSTOMER APPROVAL TO MANUFACTURE: Approved as Noted Approved with NO Exception Taken Revise and Resubmit SIGNATURE Your Title Date JOB # 703351 H -1 JOB CHICKEN NOW © SOUTHCENTER MALL DRAiNBY DC SCALE 1/2 In =1 Ft FEB 15 2008