Loading...
HomeMy WebLinkAboutPermit M08-044 - WESTFIELD SOUTHCENTER MALL - CLARKSCLARKS 466 SOUTHCENTER MALL M08 -044 Parcel No.: 6364200010 Address: Suite No: 466 SOUTHCENTER MALL TUKW Tenant: Name: CLARKS Address: 466 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DAVID A LEVEY Address: 345 SPRINGSIDE DR , AKRON OH Contractor: Name: SCOTT THOMAS CONSTRUCTION INC Address: 201 PACKETS COURT , WILLIAMSBURG VA Contractor License No: SCOTTTC077KF DESCRIPTION OF WORK: INSTALL (1) VAV BOX FOR TENANT IMPROVEMENT Value of Mechanical: $35,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC-10/06 CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 0 0 0 0 0 * *continued on next page ** M08 -044 a Permit Number: M08 -044 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Phone: Phone: 330 666 -6767 Phone: (804)564 -3455 Expiration Date: 06/19/2009 Fees Collected: $563.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15-30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 06 -09 -2008 Permit Center Authorized Signature: doc: IMC -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erformance of work. I a ; authorized to sign and obtain this mechanical permit. ��~~ Signature: � Date: C� Print Name: !p7 SPE e0 Permit Number: MO8 -044 Issue Date: 06/09/2008 Permit Expires On: 12/06/2008 Date: permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -044 Printed: 06 -09 -2008 Parcel No.: 6364200010 Address: 466 SOUTHCENTER MALL TUKW Suite No: Tenant: CLARKS 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -044 Status: ISSUED Applied Date: 02/19/2008 Issue Date: 06/09/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) doc: Cond -10/06 M08 -044 Printed: 06-09 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -044 Printed: 06-09 -2008 • 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 Th,,,-„,--"--___-., /...c.....„--„-- c.5 7 Date: [O - ` - 0 M08 -044 Printed: 06-09 -2008 , CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hIlp �%www rlu_�, a_us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address ALO .D r rna\\ Tenant Name: 0....1'drV.— Property Owners Name: We \e Mailing Address:l\(.pC\ W 1\ r'tv(e. \VGi . t \ \��" GENERAL CONTRA T+CIR INFORMATION - (Contractor information for Mechanical (pg 4} for Plumbing and Gas Piping Contact Person: E -Mail Address: Contractor Registration Number: PO --al r , y - I L( Plumbing /Gas Permit No. eUvD - Contact Person: E -Mail Address: Fax Number: Q: Applications `.Forms - Applications On Line`3 -2006 - Permit Applieation.doc Revised: 9-2006 bh Building Permit No. Mechanical Permit No. Public Works Permit Project No. (For office King Co Assessor's Tax No.:(4042O• CCM(2) Suite Number; Floor: I New Tenant: Yes ❑ ..No L City State ONTACT PERSON - who do w contact when your permit is ready to be issued Name: .(QV Ir, N. Mailing Address: \nO - - C)(" • 41'D(l 44�3� City State Zip E -Mail Address: e l t.e [ 4: Fax Number: L,pL Le , ' 5 Day Telephone: C) CbLQ(.. _ (,n \( Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: ARCIIITECT OF RECORD - Allt plans must be wet stamped by Archite Company Name • 1 \. --E' \/".4( .. ,�.. Mailing Address: J S�\nr 1de. _ r . Apra, � ^^ i4333 1 City State Zip Contact Person•L ,./ ► rJ ri . (( .�./� Day Telephone: 33 Le1a.Lo , 101( E -Mail Address: al CO t 04.-A - Fax Number: 3 -jC). CALOLD . %334 ENGINEER OF REC>)RU -' All plans must be wet stamped by En ne of Record er Company Name: Mailing Address: City State State Zip Zip Day Telephone: Page I of 6 BUILDING PERMIT INFORM' LION - 206- 431 -3670 Valuation of Project (contractor's bid price): S 1 l Existing Building Valuation: S Scope of Work (please provide detailed information i 'ce m ern verne4c Will there be new rack storage? ['� Yes P ovide All Building Areas in Square Footage Below i Floor 2 " Floor 3rd Floor Floors Accessory Stru Attached Garage Detached Gard Attached Ci Detached Carport Covered Deck Unco' Deck PLANNING DIVISION: Number of Parking Stall `'rovided: Standard: Will there be a change use? ❑ Yes Interior Remodel n that Addition to Existing Structure 200 Type of Construction per IBC 2.15 Single family building footprint (are "f the foundation of all structures, plus any decks over 18 inches d overhangs greater than 18 inches) *For an Accessory dwelling, pro %e the following: Lot Area (sq ft): Floor area of principal dwelling: Flo, area of accessory dwelling: *Provide document., shows that the principal owner lives in one of the dwellings as his or he +rimary residence. Compact: Handicap: Type of Occupancy per IBC M No If "yes ", explain: FIRE PROTEC ON /HAZARDOUS MATERIALS: g Sprink ers [v/ Automatic Fire Alarm ❑ None ❑ Other (spew r) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Ye" [r No If "yes', attach list of materials and storage locations on a separate 8 -1/2 " x 11" paper including quantities and Mate 'al Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:b'.pplications \Forms - Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 bh ❑.. No If yes, a separate permit and plan submittal will bquired. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit Obi <10,000 CFM I Incinerator — Comm/Ind MECHANICAL PERMIT INFWMATION - 206-431 -3670 MECHANICAL CONTRACTOR INFORMATION -p \ thgCJf m1 , Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $3 ooC) Scope of Work (please provide detailed infonnation): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ...lid Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: Q :\ApplicationOFomts- Applications On Line'3.2006 - Pertnii Application.doc Revised: 9 -2006 bh Fax Number: State Zip Fuel Type: Electric Gas ....0 Other: Page 4 of 6 PUBLIC WORKS PERMIT INFORMATION — 206 - 433 -0179 Scope of Work (please provide detailed information): c \r -Atel rr 4, Q'', Applications \Forms- Applications On Line \3 -2006 - Permit Application.doc Revised: 9 -2006 hh Call before you Dig: 1- 800 -424 -555.5 Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate Please refer to Public Works Bulletin #1 for fees and estimate sheet. Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction /Excavation /Fill - Right -of -way Non Right -of -way ..ValVue ❑ .. Renton ❑. Sewer Availability Provided Septic System: ❑ On -site Septic System — For on- sites 'tic system, provide 2 copies of a current s• +'lc design approved by King County Health Department. Submitted with Application (mark boxes w h a . ' lv ❑ ...Civil Plans (Maximum Paper Size — 22" ❑ ...Technical Information Report (Storm Draina ❑ .. G chnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ 'ement(s) ❑ .. „ " intenance Agreement(s) ❑...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ ...Total Cut cubic yards ❑ Work in Flood Zone ❑ ...Total Fill cubic yards ❑ .. rm Drainage ❑ ...Sanitary Side Sewer ❑ Abandon Septic Tank ❑ ...Cap or Remove Utilities L:.. Curb Cut ❑ ...Fronta Improvements .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention Fire Protect' Irrigation Domes t' ater ❑ .. Highline ❑..Re -.n ❑ .. Seattle ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Siz- .. WO # ❑ ...Temporary Water Meter .e .. WO # ❑ ...Water Only Meter Size WO # ❑...Deduct Water ` er Size ❑ ...Sewer Main Extensi. Public Private ❑ ...Water Main Exten n Public Private FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund /Billing: Name: Mailing Address: Day Telephone: City State Zip Page 3 (4'6 D' PERMIT APPLICATION NOTES - Applicable: to all: .,permits in this application • Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated.. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND i AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUiLDiI'.AW ER OR AUTHORIZED NT: Signature: Print Name -n\/ In P, Mailing Address:] SFr k( \ d.Q r I Date Application Accepted: O2ji'o1 QAApplientions\Fomu- Applications On Line'4.2006 - Permit Application.doc Revixd: 9 -2006 bh Date Application Expires: Date: 02 4.10/0e, Day Day Telephone:, Lsa�aCe , L Uri 4- mn otk 44333 City State Zip 011 ig Staff Initials: ( 1,-- Page 6 of 6 i Fixture Type: Qty Fixture Type: Qt Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) t Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial < Rea •tor, indirect waste Clothes washer, domestic Floor drain r Sinks Dental unit, cuspidor Shower, single h .: trap Urinals Dishwasher, domestic, with independent drain Lavatory 1 Water Closet ' Building sewer or trailer park sewer Rain water s i':tem — per drain (insi .; ' building) Water heater and /o vent Additional medical gas inlets /outlets -- six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or teration of water piping . /or water treating equip ` nt f` r Repair or alteration of drainage or vent piping Medical gas piping system serving one to five 'nlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION 206- 431 -3670 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION 10 b «' m t�e0 Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumb g work (contractor's bid price): $ Si cx= Valuation of Gas Pipi work (contractor's bid price): $ Scope of Work (please pr 'de detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and /or gas piping outlets (g installed and the quantity below: Q:'.Applications\Fo ms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 hh Sewer: Page 5 of 6 RECEIPT NO: R08 -00458 User ID: 1165 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Payee: DAVID A LEVY & ASSOCIATES SET TRANSACTIONS: Set Member Amount D08 -089 1,321.05 EL08 -158 164.00 M08 "= „0.44 7.50 PG08 -047 32.00 TOTAL: 1,524.55 TRANSACTION LIST: Type Method Description Payment Check 11959 ACCOUNT ITEM LIST: Description BUILDING - NONRES ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT Initials: JEM Payment Date: 02/19/2008 SET ID: S000000961 SET NAME: Tmp set/Initialized Activities TOTAL: Total Payment: 1,524.55 Amount 1,524.55 1,524.55 Account Code Current Pmts 000/322.100 97.75 000.345.832.00.0 164.00 000/345.830 1,262.80 TOTAL: 1,524.55 9790 02/1P -?710 TOTAL 152A.55 Project:/ / Type of Inspection: i d Address: v6 6 _ 1i' ��/ // Date Called: Special Instructions: Date Wanted: �7 / g a.m.. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION fa- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: r Inspector: I Date /7% ❑ $6 'd0 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be p id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: h Harr 5 'Vt.:, Y{�ti ^ :'4:S%1.•�'"� "? .... v. ,:``K't°. • Project: a IaMcS Type of Inspection: i Address: 16 le l77,9,0L Date Called: Special Instructions: Date Wanted: y /1 , /n? a.m. p.m. Requester: Phone No: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Haf PERMIT NO. (206)431 -3670 ,Approved per applicable codes. Corrections required pri6r to approval. COMMENTS: Vim (? e -!{.vn Ad6ave5S no. 62 _ Po 4 veS 1.014 i4' —IA Inspector Date: 7 ❑ $60.00 REINSPECTION FEE EE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: IDate: • Project: i/ / / /' " / /!!` Type of Inspection Address: Date Called: Special Instructions: Date Wanted: / � D � p .m . Requester: Phone No: m INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 112 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 l% Approved per applicable codes. Corrections required prior to approval. COMMENTS: OK got c6ver- Date: 7 /V / El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Project: n 92,CS Type o Inspection: h - n/ Address / Date Called: Special Instructions: Date Wanted: �� Date �-4'..J p.m. Requester: Phone No 6/25-97/ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: p Inspector: I ❑ $60.9 EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pai t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: RECEIPT NO: R08 -02032 Initials: JEM User ID: 1165 Payee: SCOTT THOMAS CONSTRUCTION SET ID: 0304A SET TRANSACTIONS: Set Member Amount D08 -089 1,848.75 EL08 -158 656.00 M 7104 ° 4 ' 556.25 PG08 -047 68.00 TOTAL: 1,848.75 TRANSACTION LIST: Type Method Payment ACCOUNT ITEM LIST: Description Check 157397 BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE SET RECEIPT Description SET NAME: CLARKS TOTAL: Account Code 000/322.100 000.322.101.00.0 000.322.102.00.0 000/345.830 000.322.103.00.0 000/386.904 TOTAL: Payment Date: 06/09/2008 Total Payment: 3,129.00 Amount 3,129.00 3,129.00 Current Pmts 1,784.25 656.00 451.00 165.25 68.00 4.50 3,129.00 3421 06/09 0711 TOTAL 3129.00 COMMENTS: - S Fire Alarm: Type o f Inspection: /Ftlk P e. c � ` L L__ Address: L i c Suite #: S . S P -C , ivLprc__ o 4 Special Instructions: Phone No.: ff ire ! J { Project: C. t k - S Fire Alarm: Type o f Inspection: /Ftlk P e. c � ` L L__ Address: L i c Suite #: S . r.-, �r L I_ Contact Pe on: ' Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER W . Approved per applicable codes. Word /Inspection Record Form.Doc INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 1/13/06 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Corrections required prior to approval. Inspector: Hrs.: Date: -7 / (7 /n 9 4 6 ( -- 1 - 1 $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -044 PROJECT NAME: SITE ADDRESS: X Original Plan Submittal CLARKS Response to Correction Letter # 466 SOUTHCENTER MALL Revision # DATE: 02 -19 -08 Response to Incomplete Letter # After Permit Issued DEPARTMENTS: 2 Dg � L ' Bung Di Vision Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Approved Notation: Documents/routing slip.doc 2 -28 -02 a APPROVALS OR CORRECTIONS: REVIEWER'S INITIALS: ��ERMIT COORD COPY frj 6(f AIM/ i -1 4 Fire Prevention Structural Incomplete Planning Division Permit Coordinator n DUE DATE: 02 -21 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: Structural Review Required Approved with Conditions n No further Review Required n DATE: DUE DATE: 03-20-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials: CODES 2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS 2006 WASHINGTON STATE ENERGY CODE 2005 NATIONAL ELECTRICAL CODE BUILDING DEPARTMENT CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD. #100 TUKWILA, WA 98188 PH. 206 -431 -3670 CODE INFORMATION FULLY SPRINKLERED CONSTRUCTION TYPE: 2B OCCUPANCY CLASS: M GROSS SQUARE FOOTAGE NET SQUARE FOOTAGE FRONT OF HOUSE AREA = 1,270 SF (30 S.F./ OCCUPANT) BACK OF HOUSE AREA = 1,243 SF (300 S.F. / OCCUPANT) TOTAL OCCUPANT LOAD NO. OF EMPLOYEES = 3 PERSONS ENGINERING CONSULTANTS MECHANICAL POINT ONE DESIGN 9941 YORK THETA DRIVE NORTH ROYALTON, OH 44133 PH. 440 -230 -1800 FX. 440 -230 -1831 ELECTRICAL STADELMAN ASSOCIATES 931 PORTAGE TRAIL CUYAHOGA FALLS, OH 44221 PH. 330- 926 -2600 FX. 330- 926 -4531 DEVELOPER WESTFIELD 11601 WILSHIRE BLVD. 14TH FLOOR LOS ANGELES, CA 90025 CONTACT: JOSH KIMMEL e -mail: JKIMMEL @WESTFIELD.COM PH:310- 893 -4761 OWNER CLARKS 156 OAK STREET NEWTON UPPER FALLS, MA 02464 BOB JOHNSON SENIOR DIRECTOR OF CONSTRUCTION PH_ (617) 796 -5056 FX. (617) 243 -4210 DENNIS HORN DIRECTOR OF CONSTRUCTION PH. (617) 243 -4214 FX. (617) 243 -4210 2,700 SF 2,521 SF 43 = 5 48 KEY PLAN CLARKS LEVEL 1 OF 3 SPACE #1010 WESTFIELD SOUTHCENTER 466 SOUTHCENTER MALL TUKWILA, WA 98188 STORE # 753 0' -0 15' -9 11 qCq Ate VICINITY MAP WESTFIELD SOUTHCENTER 466 SOUTHCENTER MALL SPACE #1010 TUKWILA, WA 98188 SOUTHCENTER RD.. SO civ WESTFIELD / SOUTHCENTER /, LEASELINE TO LEASELINE BAKER BLVD. STRANDER BLVD. GROSS LEASEABLE AREA 2,700 SQ. FT. 5 LEASELINE TO LEASELINE REVISION: 02- 13- 08-PER LANDLORD COMMENTS -AKS LOD PLAN SCALE: 1/8"=1'-0" SEPARATE PERMIT REQUIRED �gchanic� C.) Electrica% V Iumbing as piping City of Tukwila �IJILQII ; , rAvisiON 01 -30 -2008 nge5 ~- �> Wo Re'. vAns adflj; and may inctude ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS _REVi.E '�':., , s CODE CC i'Ll' i tc� scope .Ff of 76.4 ria rt su`bi Ft �.. f.?� a ; ; - ;lien ie've FILE Copy Permit No. Mar review approval Is subject to errors and omissions. Approval of construction documents does not aulhodze the violation of any adopted code or order. Receipt of approved Field Copy and condili is acknowledged By City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 1 9 2000 PERMIT CENTER INDEX OF DRAWINGS ARCHITECTURAL C100 COVER SHEET /INDEX/CODE INFO C101 GENERAL NOTES C102 FINISH SCHEDULE / RESPONSIBILITY SCHEDULE C103 MOULDING SCHEDULE/ PROFILES A100 FLOOR PLAN A101 ENLARGED TOILET PLAN / ELEVATIONS A102 EGRESS PLAN A200 REFLECTED CEILING PLAN A300 ENLARGED STOREFRONT PLAN/ ELEVATION A400 A401 INTERIOR ELEVATIONS A500 STOREFRONT SECTIONS A501 STOREFRONT DETAILS A502 STOREFRONT DETAILS A503 STOREFRONT DETAILS A600 A700 DOOR SCHEDULE/ DETAILS/ NOTES A701 THRESHOLDS & FLOORING TRANSITIONS A800 A801 A802 A803 AS100 AS101 AS102 PLUMBING P100 PARTIAL PLUMBING PLAN / DETAILS P200 PLUMBING SPECIFCATIONS / SCHEDULE MECHANICAL M100 M200 MECHANICAL SYMBOLS, NOTES & SCHEDULES ELECTRICAL El 00 E200 E300 INTERIOR ELEVATIONS INTERIOR DETAILS FIXTURE PLAN FIXTURES - DETAILS FIXTURES - DETAILS FIXTURES - DETAILS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS MECHANICAL PLAN LIGHTING PLAN POWER PLAN ELECTRICAL DETAILS E400 ELECTRICAL SYMBOLS & NOTES/ LIGHTING FIXTURE SCHEDULE E500 POWER RISER DIAGRAM / PANEL SCHEDULES E600 ELECTRICAL SPECIFICATIONS REGISTERED 400) ARCHITECT D AVID ALLEN LEVY TATE OF WASHI ON 943 I A 1I I A & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 041 DESIG_ MAKE MODEL AREA SERVED SERVICE CFM ESP MOTOR HP SERVED MAX. SOUND LEVEL FAN TYPE WEIGHT REMARKS EF -1 COOK "GEMINI" GC -320 TOILET ROOM EXHAUST 120 .375 75 WATTS 120V/1/60 4.1 SONES CEILING MOUNTED 25 LBS. MOUNTED IN DECK ABOVE TOILET ROOM IN JOIST AT 16" Q.C., AUTOMATIC BACKDRAFT DAMPER, INTEGRAL ALUMINUM EXHAUST GRILLE. DESIG. MAKE MODEL SIZE MAX' CFM MAX' N.C. DAMPER FINISH REMARKS A TITUS OMNI 8 "0 250 30 AG -75 PAINT TO MATCH CL'G. LAY -IN 24 "x24" PANEL B TITUS OMNI 8 "0 250 30 AG -75 PAINT TO MATCH CL'G. SURFACE MOUNTED FRAME TRM (LAY -IN 12 "x12" PANEL) C TITUS OMNI 15 1000 30 NONE PAINT TO MATCH CL'G. LAY -IN 24 "x24" PANEL (RETURN) ❑ TITUS OMNI 12 "0 500 30 NONE PAINT TO MATCH CL'G. LAY -IN 24 "x24" PANEL (RETURN) DUCT SYSTEM SMACNA PRESSURE CLASS SMACNA SEAL CLASSMATERIAL DUCT SUPPLY AIR DUCTWORK DOWNSTREAM OF FPB 2" A GALVANIZED STEEL SUPPLY AIR DUCTWORK UPSTREAM OF FPB 4" A GALVANIZED STEEL EXHAUST AIR DUCTWORK 1 „ C GALVANIZED STEEL MECHANICAL NOTES: 1. THE MECHANICAL CONTRACTORS SHALL BE HELD TO HAVE REVIEWED ALL SHEETS OF THESE CONTRACT DOCUMENTS AND WILL BE RESPONSIBLE FOR PERFORMING ALL WORK INDICATED ON ANY SHEET. THE MECHANICAL CONTRACTORS WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE WORK OF OTHERS. 2. REFER TO SHEET M200 FOR MECHANICAL EQUIPMENT SCHEDULES, NOTES AND SHEET M3 FOR SPECIFICATIONS. 3. REFER TO SHEET A200 FOR LOCATION OF DIFFUSERS IN THE REFLECTED CEILING PLAN, AND FIRE RATING NOTES. 4. COORDINATE ALL NEW DUCT ROUTING AND EQUIPMENT LOCATIONS WITH EXISTING BUILDING CONDITIONS 5. THE DUCTWORK SHALL BE SUPPORTED BY STRAP HANGERS AROUND DUCTWORK. DO NOT SUPPORT DUCTWORK FROM METAL DECK. 6. THE MECHANICAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO STARTING WORK AND ADJUST DUCTWORK, ETC... TO CORRESPOND TO THE EXISTING CONDITION REQUIREMENTS. 7. MECHANICAL CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR FOR MOUNTING FRAME FOR DIFFUSER 'B'. 8. TENANT SHALL FURNISH TWO (2) COPIES OF A CERTIFIED INDEPENDENT TEST & BALANCE REPORT BY LANDLORD'S DESIGNATED CONTRACTOR TO LANDLORD. 9. ALL EQUIPMENT, PIPING AND ETC. EXPOSED INSIDE BUILDING SHALL BE PAINTED WITH COLOR AS SELECTED BY ARCHITECT. 10. HVAC CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS IN FIELD BEFORE CONSTRUCTION. 11. PROVIDE ALL REQUIRED OFFSETS FOR DUCTWORK. HVAC SYMBOL LEGEND SYMBOL AFF G RA EA GC MC PC EC LL 7 z J DESCRIPTION ABOVE FINISHED FLOOR ABOVE FINISHED GRADE FAN POWERED BOX UPPLY AIR RETURN AIR EXHAUST AIR GENERAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR ELECTRICAL CONTRACTOR LANDLORD SUPPLY AIR DIFFUSERS RETURN AIR REGISTER EXHAUST FAN MANUAL VOLUME DAMPER SENSOR SCHEDULE NUMBER CFM UNDERCUT DOOR BY GC MECHANICAL NOTES: '12. SEE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS AND REGISTERS. 13. PERFORM INSTALLATIONS IN ACCORDANCE TO LANDLORDS SPECIFICATIONS. 14. VAV BOX SHALL BE CONTROLLED BY A SENSOR THRU LANDLORD BMS. COOLING AIR VALVE SHALL MODULATE FROM FULL OPEN TO CLOSED TO MAINTAIN SETPOINT. 15. MECHANICAL CONTRACTOR SHALL COORDINATE WITH LANDLORD FOR THE PURCHASE OF SENSOR FOR THE NEW VAV BEING INSTALLED. 16. PROVIDE RELAYS AND ALL EQUIPMENT AS REQUIRED FOR CONNECTION TO LANDLORD SYSTEM. 17. VAV SHALL BE MOUNTED ABOVE CEILING USING ALL THREADED RODS & SPRING VIBRATION ISOLATORS.. 18. ANY SYSTEM OR COMPONENTS THAT ARE NOT REUSED SHALL BE REMOVED. 19. EF -1 EXHAUST FAN SHALL BE OPERATED FROM TOILET ROOM WALL LIGHT SWITCH WITH DELAY TIMER TO PROVIDE INTERMITENT OPERATION. 20. MECHANICAL CONTRACTOR SHALL REFER TO DRAWING M200 FOR EQUIPMENT MODEL NUMBER, ACCESSORIES & CONTACT INFORMATION. UNITS SHALL BE ORDERED AS S *ON AS CONTRACTS ARE AWARDED. 21. DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. EXIST. LL PROVIDED 10 "0 EA MAIN. 8". I I0 "x10" EXTEND 4 CONNECT NEW I600 SA DUCT INTO EXIST. 20 "0 SA DUCT STUB PROVIDED BY LL. VERIFY EXACT LOCATION IN FIELD. EXIST_ LL PROVIDED 22"0 EA MAIN. FAN SCHEDULE DUCTWORK SCHEDULE NOTE: ALL DUCTWORK SIZES ARE AIRWAY DIMENSIONS EXTEND NEW 8 EA DUCT INTO LL PROVIDED EA MAIN_ VERIFY EXACT LOCATION IN FIELD. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) NEW FP15-1. SET BOX TO DELIVER 2600 CFM. 18 "x14" 20 "x16" Oa r SENSOR LOCATION FOR FP15-1. VERIFY EXACT LOCATION W /ARCHITECT FOR 18 "x14" 8 . II - 8 " x6 " FLEX CONN. (TYPICAL) 10 "x10" NEW EF -I (120 CFM) 10 "$ DUCT MOUNTED SMOKE DETECTOR IN SA DUCTWORK W /CONNECTION TO MALL'S FIRE ALARM SYSTEM F SI- IUTDOWN_ MANUAL VOLUME DAMPER (T1rF9 f EXIST. LL PROVIDED 24 "x14" SA MAIN. EXIST. LL PROVIDED 26 "x22" SA MAIN. NOTE: RETURN AIR WILL BE THRU RETURN AIR PLENUM. ALL CONTRACTORS SHALL PROVIDE MATERIALS SUITABLE FOR PLENUM APPLICATIONS. MECHANICAL CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR FOR 6" MINIMUM CLEAR NEIGNT ABOVE COMMON DEMISING WALL 4 STRUCTURE TO ALLOW RETURN AIR BACK TO LANDLORD UNIT. ) LC Ls Lc Ls DIFFUSER, REGISTER, LOUVER SCHEDULE NOTE: MECHANICAL CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR FOR PAINTING OF SUPPLY DIFFUSERS AND RETURN GRILLES IN SALES AREA. (c 10 - \ 46,, 10 NOTE: MECHANICAL CONTRACTOR TO COORDINATE WITH LANDLORD FOR SIZE 4 LOCATION OF TRANSFER AIR OPENING IN DEMISING WALLS FOR THE RETURN AIR TO MALL. SCALE: ati] 1/4"=f-0" ME PLAN RE O'EW a..i ,'r• CODE CCMPLIA1 Y0 FEET p451-3 a � x• ,s';, RECEIVED CITY OF TUKWILA WILA FEB 19 2008 PERMIT CENTER POD 01- 302008 & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS REVISION : Q 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : MECHANICAL PLAN M1 00 tv1O9Oi1L4 CALCULATIONS: CLARKS - TUKWILA, WA DESIGN CONDITIONS: SUMMER: WINTER: AREAS: SALES AREAS STOCK LAVATORY TOTAL SPACE CFM /S.F. 1260 SQ.FT. 1205 SQ.FT. 60 SQ.FT. 2525 SQ.FT. 1.03 PEOPLE: 17 - BASED ON 75 SQ.FT. /PERSON IN SALES AREA VENTILATION: 510 CFM BASED ON .30 CFM /SF SALES & .15 CFM /SF STOCK HEAT GAIN FACTOR QUANTITY SENSIBLE GAIN LATENT GAIN PEOPLE: LIGHTS: RECEPTACLES MISCELLANEOUS TOTAL ROOM GAIN: VENTILATION AIR: TOTAL HEAT GAIN: SUPPLY AIR CFM: INDOOR OUTDOOR 75 F DB /63 F WB 84E DB /65F WB INDOOR 70F DB 250/200 3.41 3.41 3.41 THRU MALL SYSTEM OUTDOOR 21F DB 17 5,250 WATTS 3,000 WATTS 4,000 WATTS ROOM SENSIBLE GAIN 46,023 BTU /HR 1.085 x (75 - 55) 21.7 4,250 BTU /HR 17,903 BTU /HR 10,230 BTU /HR 13,640 BTU /HR 46,023 BTU /HR AT 9F DB AT 49F DB S.F./TON 389 3,400 BTU /HR 3,400 BTU /HR 46,023 BTU /HR + 3,400 BTU /HR 49,423 BTU /HR 4.1 TONS = 2121 CFM USE 2600 CFM vI EC HAN I CAL GENERAL A. CONTRACTOR ALSO REFERRED TO ALL ARCHITECTURAL, ELECTRICAL AND OTHER LANDLORD DRAWINGS PERTAINING TO PROJECT. ALL OF ABOVE MENTIONED DRAWINGS, AS WELL AS THEIR RESPECTIVE SPECIFICATIONS, ARE A PART OF CONTRACT DOCUMENTS. B. MECHANICAL DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER, FURNISH ANY MATERIAL OR LABOR CALLED FOR IN ONE EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. C. INSTALL AND CONNECT EQUIPMENT, SERVICES AND MATERIALS IN ACCORDANCE WITH BEST ENGINEERING PRACTICE AND ACCORDANCE WITH VARIOUS MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. FURNISH AND INSTALL COMPLETE AUXILIARY PIPING, VALVES, WATER SEALS, ELECTRICAL CONNECTIONS, ETC., RECOMMENDED BY MANUFACTURER OR REQUIRED FOR PROPER OPERATION. D. FURNISH MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON DRAWINGS OR CALLED FOR IN SPECIFICATIONS BUT WHICH IS OBVIOUSLY A COMPONENT PART OF AND NECESSARY TO COMPLETE WORK OF SIMILAR CHARACTER. E. This CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, LICENSES AND /OR LANDLORD FEES, BACKCHARGES, ETC., REQUIRED TO CARRY OUT THIS WORK. HE SHALL PAY FOR ALL CHARGES MADE BY INSPECTION. NOTE: ALL CONTRACTORS SHALL BE LICENSED IN THE STATE, CITY, ETC. & APPROVED BY LANDLORD TO PERFORM ALL NEW WORK. F. THIS CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, ALL LOCAL LEGAL REQUIREMENTS, AND MALL REQUIREMENTS. ALL LAWS, RULES AND REGULATIONS OF STATE AND LOCAL GOVERNING AGENCIES SHALL BE CONSIDERED A PART OF THESE SPECIFICATIONS AS FULLY AS IF WRITTEN HEREIN. NO EXTRA COMPENSATION WILL BE ALLOWED FOR ANY CHANGES NECESSARY FOR CODE COMPLIANCE REGARDLESS OF THE METHOD OF INSTALLATION SHOWN ON THE DRAWINGS OR SPECIFIED. G. WHEN WORK IS COMPLETED, THIS CONTRACTOR SHAW FURNISH TO THE GENERAL CONTRACTOR CERTIFICATES OF APPROVAL FROM THE RESPONSIBLE INSPECTION AGENCIES. H. TESTING OF ALL WORK UNDER THIS CONTRACT SHALL BE DONE BY THE CONTRACTOR. ALL APPARATUS, EQUIPMENT, FIXTURES, ETC., SHALL FULLY MEET THE REQUIREMENTS OF THESE SPECIFICATIONS AND DRAWINGS. I. THE BID SHALL CONTEMPLATE THE FURNISHING AND INSTAWNG OF MATERIAL AND EQUIPMENT, EXACTLY AS SPECIFIED OR SHOWN AS SIMILAR BY THE CONTRACT DOCUMENTS. THE CONTRACTOR SUBMITTING ON SIMILAR EQUIPMENT WILL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH CHANGES IN ARCHITECTURAL, STRUCTURAL, MECHANICAL AND /OR ELECTRICAL TRADES DUE TO THE SIMILAR EQUIPMENT CHARACTERISTICS SUBMITTED. NOTE: OTHER MANUFACTURERS MAY BE SUBSTITUTED IF EQUAL IN PHYSICAL & PERFORMANCE CHARACTERISTICS, AND APPROVED BY THE OWNER'S REPRESENTATIVE UNLESS OTHERWISE NOTED. J. INSTALL FINAL APPLICATION OF LUBRICATION OIL, AND ALL OTHER SUPPLIES NECESSARY TO PLACE THE EQUIPMENT IN OPERATION. K. CONTRACTOR SHALL GUARANTEE HIS WORK TO BE FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE. L ALL POWER WIRING OF MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. FURNISH THE ELECTRICAL CONTRACTOR WIRING DIAGRAMS FOR ALL ELECTRICALLY POWERED EQUIPMENT PROVIDED WITH THE CONTRACT WHICH SHALL INDICATE THE SERVICE REQUIRED AND ELECTRIC LOAD INVOLVED, M. THIS CONTRACTOR SHALL VISIT SITE BEFORE SUBMITTING BID AND MAKE ALL NECESSARY OBSERVATIONS, MEASUREMENTS, AND NOTE CONDITIONS UNDER WHICH HIS WORK IS TO BE PERFORMED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR FAILURE TO DO SO. THIS CONTRACT INVOLVES REMODELING OF EXISTING BUILDING AND THEREFORE SHALL FIELD LOCATE EXISTING DUCTWORK, PIPING AND SEWERS BEFORE STARTING WORK. N. SUBMIT CERTIFIED SHOP DRAWINGS (COMPLETE WITH CONTRACTOR STAMP OF REVIEW & APPROVAL), CATALOG SHEETS FOR EQUIPMENT, FIXTURES, 1/4" SCALE DUCTWORK LAYOUT AND WIRING DIAGRAMS IN SIX (6) COPIES TO THE ARCHITECT FOR REVIEW. EACH CONTRACTOR IS RESPONSIBLE TO DISTRIBUTE APPROVED SHOP DRAWINGS TO ALL OTHER TRADES AFFECTED BY HIS WORK, EQUIPMENT, ETC., FOR COORDINATION. 0. ASSEMBLE AND SUBMIT TO THE ARCHITECT FOR SUBSEQUENT SUBMISSION TO THE OWNER, THREE (3) COMPLETE SETS OF OPERATIONS MANUALS AND MAINTENANCE REQUIREMENTS, COPY OF APPROVED SHOP DRAWINGS OF FIXTURE CUTS WITH MANUFACTURER'S NAME AND MODEL NUMBER, EQUIPMENT GUARANTEES & WARRANTIES, ETC., FOR EACH ITEM FURNISHED. AS BUILT DRAWINGS & SPECIFICATIONS, AFFIDAVIT OF WAIVER OF LIEN, OPERATING INSTRUCTIONS & SERVICE MANUALS, CERTIFICATE OF HVAC INSPECTION, SPARE PARTS GUARANTEES BEYOND ONE YEAR OF SERVICES, ETC. P. ALL CONTRACTORS MUST COORDINATE EACH PIECE OF EQUIPMENT WITH ALL OTHER TRADES (GENERAL CONTRACTOR, PLUMBING CONTRACTOR, MECHANICAL CONTRACTOR, ELECTRICAL CONTRACTOR, ETC...) AFFECTED BY THAT PIECE OF EQUIPMENT (WEIGHTS, POWER REQUIREMENTS, VOLTAGES, ETC...) PRIOR TO ORDERING EQUIPMENT AND AGAIN PRIOR TO INSTALLATION. NO EXTRA COMPENSATION WILL BE APPROVED IF COORDINATION IS NOT PERFORMED BY EACH RESPECTIVE CONTRACTOR AND SUBCONTRACTOR. Q. DRAWING & SPECIFICATIONS - MECHANICAL DRAWINGS ARE DIAGRAMMATIC IN NATURE & ARE NOT INTENDED TO BE SCALED FOR DIMENSIONS. ALL DIMENSIONS SHALL BE TAKEN FROM CERTIFIED EQUIPMENT DRAWINGS & FROM THE STRUCTURE ITSELF BEFORE PERFORMING ANY WORK. R. CUTTING, PATCHING & FLASHING - THE HVAC & PLUMBING CONTRACTORS SHALL PERFORM ALL NECESSARY CUTTING, SUBSEQUENT PATCHING & REQUIRED FLASHING FOR ALL ITEMS NECESSARY FOR THIS PART OF THE CONTRACT TO THE SATISFACTION OF THE OWNER. CONTRACTOR TO COORDINATE ALL WORK WITH THE GENERAL CONTRACTOR. S. ANY DISCREPANCIES SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE IN WRITING PRIOR TO THE LETTING OF THE CONTRACT. AFTER LETTING OF THE CONTRACT, THE CONTRACTOR AT HIS OWN EXPENSE, SHALL RECTIFY THE DISCREPANCY AS DIRECTED BY THE OWNER'S REPRESENTATIVE. HEATING, VENTILATING & AIR CONDITIONING SPECIFICATIONS A. IN RESPECT TO ALL MATERIALS REQUIRED, THE CONTRACTOR SHALL FURNISH MATERIALS MEETING AIEE, NEMA, NELA, ASME AND ASTM SPECIFICATIONS. THE INSTALLATION OF ALL WORK SHALL CONFORM TO ASHRAE GUIDE AND SMACNA SHEET METAL PROMOTION PLAN STANDARDS. B. MATERIALS SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED, AND SHALL BE PROTECTED FROM ALL INJURY UNTIL FINAL ACCEPTANCE OF THE SYSTEM. C. THIS CONTRACTOR SHALL REMOVE ALL TOOLS, SURPLUS MATERIALS AND DEBRIS OF ALL KINDS FROM HIS WORK AND LEAVE ALL IN A CLEAN, PERFECT CONDITION, FULLY SATISFACTORY TO THE ARCHITECT. D. CONTRACTOR SHALL PROVIDE OWNER WITH TWO (2) SETS OF "AS- BUILT" DRAWINGS. E. FURNISH ALL MATERIALS, TRANSPORTATION, RIGGING, HOISTING, ETC. TO PROVIDE A COMPLETE AND OPERABLE HEATING, VENTILATING AND AIR CONDITIONING SYSTEM. F. ALL EQUIPMENT IS TO BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, ACCORDING TO MANUFACTURERS RECOMMENDATIONS AND GOOD PRACTICES. COORDINATE ALL WORK WITH OTHER TRADES AND WITH THE GENERAL CONTRACTOR, OWNER'S FIELD REPRESENTATIVE AND MALL PERSONNEL G. ALL TEMPERATURE CONTROL WIRING SHALL BE DONE BY THE MECHANICAL CONTRACTOR. THIS CONTRACTOR SHALL FURNISH ALL REQUIRED CONTROLS AND WIRING DIAGRAMS AND SHALL SUPERVISE INSTALLATION. H. SYSTEM IS TO BE AIR BALANCED BY AN INDEPENDENT CERTIFIED BALANCE COMPANY, TO INCLUDE DIFFUSER CFM, RETURN CFM AND EXHAUST CFM WITH TWO (2) REPORTS SUBMITTED TO THE LANDLORD AND ONE (1) REPORT TO OWNER'S REPRESENTATIVE. MAINTENANCE MANUALS TURNED OVER TO OWNER'S REPRESENTATIVE BEFORE FINAL ACCEPTANCE. ALL SYSTEMS AND EQUIPMENT ARE TO BE GUARANTEED FOR PARTS AND LABOR FOR ONE YEAR. I. DUCTWORK AND PLENUMS SHALL BE AS SCHEDULED ON THE DRAWINGS PER SMACNA "DUCT CONSTRUCTION" CLASSIFICATION. DUCTWORK SHALL BE GALVANIZED PRIME SHEET METAL. J. SHEET METAL FABRICATION AND INSTALLATION SHALL BE AS FOLLOWS: 1. ALL DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH STANDARDS SET FORTH IN LATEST EDITION OF THE ASHRAE GUIDE AND SMACNA STANDARDS UNLESS MODIFIED HEREIN. 2. DUCT DIMENSIONS ARE GROSS EXCEPT FOR UNED DUCTS WHERE DIMENSIONS ARE NET FREE AREA. 3. DUCT SIZES SHOWN ON THE PLANS ARE ACTUAL SHEET METAL INSIDE DIMENSIONS AND SHALL BE ADHERED TO UNLESS JOB CONDITIONS REQUIRE ALTERATIONS. REVISIONS TO DUCT SIZES SHALL BE BASED ON THE "EQUAL FRICTION" METHOD. 4. ALL ELBOWS IN THE DUCT SYSTEM SHALL BE MADE WITH CENTERIJNE RADIUS OF ONE AND ONE -HALF (1 1/2) TIMES THE TURNING WIDTH OF THE DUCT. WHERE SPACE PROHIBITS THE SPECIFIED MINIMUM RADIUS, SQUARE ELBOWS WITH DOUBLE RADIUS TURNING VANES SHALL BE INSTALLED. CHANGES IN DUCT SIZES SHALL BE 15'. DIVERGING AND 60'. CONTRACTING, FLOW MAXIMUM ANGLES. 5. THE GENERAL ROUTE OF THE DUCTS IS SHOWN ON THE PLANS. THE EXACT ROUTE SHALL BE DETERMINED BY JOB CONDITIONS AND SHALL BE COORDINATED WITH ALL OTHER TRADES. ALL GRILLES, REGISTERS, DIFFUSERS, ETC., SHALL BE LOCATED SYMMETRICALLY WITH ELECTRIC LIGHT ARCHITECTURAL TREATMENT, ETC. 6. HANGERS TO BE 8 FT. CENTERS MAXIMUM & AT EACH CHANGE IN DIRECTION WITH 1" GAUGE MINIMUM STRAPS FOR DUCTS (BENT UNDER BOTTOM OF DUCT AND ATTACHED). DUCTWORK SHALL BE SEALED. 7. INSTALL DUCTWORK TIGHT TO BOTTOM OF STRUCTURAL STEEL OR AS HIGH AS POSSIBLE. 8. NO FIBERGLASS DUCTBOARD WILL BE PERMITTED. K. FURNISH AND INSTALL ALL MANUAL SPLITTER DAMPERS AND DEFLECTORS INDICATED ON DRAWINGS OR NECESSARY TO PROPERLY DISTRIBUTE AND BALANCE AIR. L. INSULATION SHALL BE AS FOLLOWS: 1. ALL INSULATION, VAPOR BARRIER, JACKETS AND ADHESIVE USED FOR APPLYING INSULATION SHALL HAVE FIRE AND SMOKE HAZARD RATINGS AS TESTED UNDER ASTM-84, NFPA -255, AND U.L 723 NOT EXCEEDING A FLAME SPREAD 25 AND SMOKE DEVELOPED OF 50. 2. ALL CONCEALED SUPPLY AIR SHALL BE WRAPPED WITH OWENS - CORNING TYPE 150, 1 -1/2" DUCT WRAP (6.0 R- VALUE). TAPE ALL SEAMS WITH MINIMUM 2" WIDE TAPE. RETURN AIR DUCTWORK TO BE UNED WITH 1" ACOUSTIC LINING, OWENS- CORNING TYPE 300. THERMAL CONDUCTIVITY OF 0.24. 3. OTHER APPROVED MANUFACTURERS: MANSVILLE, KNAUF, CERTAINTEED M. PROVIDE BRANCH SUPPLY AIR DUCTWORK WITH SPIN -IN TRUNK CONNECTIONS WITH AIR SCOOP AND VOLUME DAMPER OR 45 DEGREE ENTRY FITTINGS OR BELL MOUTH. N. PROVIDE FLEXIBLE CONNECTION AT THE INLET AND OUTLET OF THE AIR MOVING UNIT, EXHAUST FANS CONNECTED TO DUCTWORK. MATERIALS SHALL BE NON - COMBUSTIBLE TWELVE (12) OUNCES PER SQUARE YARD, NFPA -90A APPROVED. 0. FLEXIBLE INSULATED DUCT SHALL BE THERMAFLEX TYPE M -KE FACTORY ASSEMBLED DUCT CONSISTING OF COLD ROLLED FLAT STEEL SPRING, CONTINUOUS NON- PERFORATED INNER AIR SEAL LINER, 0.23 THERMAL CONDUCTANCE FIBERGLASS INSULATION, AND FIBERGLASS REINFORCED METAUZED FILM VAPOR BARRIER. DUCTS SHALL BE LISTED BY UL, CONFORM TO NFPA CLASS I WITH FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPMENT OF 50 OR LESS. FLEXIBLE DUCTS SHALL BE PULLED TIGHT TO ELIMINATE SAGS AND KINKS. (SIMILAR MANUFACTURER: FLEXMASTER) FPB -1: NEW FAN POWERED VARIABLE AIR VOLUME BOX. TRANE MODEL VPEF -1406, 14 "0 INLET, 1/2 HP FAN MOTER ® 277VAC WITH 3.8 FLA, AUXILIARY 8.0 KW HEATER, 480V/3/60 POWER, COORDINATE WITH MALL PERSONEL TO SET BOX TO DELIVER 2600 CFM SUPPLY AIR. HVAC E IPMENT SHALL BE FOLLOWS. NOTES: MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION WITH ELECTRICAL CONTRACTOR FOR ALL EQUIPMENT POWER REQUIREMENTS PRIOR TO ORDERING & INSTAWNG EQUIPMENT. DEMOLITION NOTES: 1. MECHANICAL CONTRACTOR SHALL REMOVE ALL EXISTING SUPPLY & RETURN AIR DUCTWORK INCLUDING HANGERS, DIFFUSERS, INSULATION, ETC., NOT REUSED FOR THE NEW SPACE. FIELD VERIFY EXISTING CONDITIONS. 2. MECHANICAL CONTRACTOR SHALL REMOVE AND DISPOSE OFF SITE PER LOCAL ORDINANCES ALL EXISTING MECHANICAL EQUIPMENT, FANS, VAV BOXES, ETC., COMPLETE ASSOCIATED WITH NEW SPACE UNLESS OTHERWISE NOTED TO REMAIN. ELECTRICAL CONTRACTOR TO DISCONNECT POWER. COORDINATE WITH OWNER AND LANDLORD. SEE ARCHITECTURAL DEMOLITION DRAWINGS FOR FURTHER DETAILS AND INFORMATION. CODE I FEL_: 2 City O Rasa =:,f B 1 e•r 4 z ,_;e G RECEIVED CITY OF TUKWILA LA FEB 1 9 2008 PERMIT CENTER CONSULTANT: DRAWN BY: POD ISSUE / DATE: 01-30-2008 REVISION : & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUE 1 - CONSTRUCTION DOCUMENTS 02 -13 -08 -PER LANDLORD COMMENTS SHEET TITLE : MECHANICAL SPECIFICATIONS -AKS SHEET NO . M200 HO8 O9'I