Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-046 - WESTFIELD SOUTHCENTER MALL - FOSSIL
FOSSIL 846 SOUTHCENTER MALL M08 -046 Parcel No.: 6364200010 Address: Suite No: CitAbf Tukwila Contact Person: Name: JAMES MOORE Address: 833 SE MAIN #242 , PORTLAND OR Contractor: Name: EINSTEIN MECHANICAL OF WA Address: 315 E HICKORY ST , AUBREY TX Contractor License No: EINSTMW924CK Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 846 SOUTHCENTER MALL TUKW Tenant: Name: FOSSIL Address: 846 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA MECHANICAL PERMIT DESCRIPTION OF WORK: MECHANICAL FOR NEW TI: NEW AIR HANDLING UNIT AND DUCT WORK Value of Mechanical: $12,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 1 0 0 1 0 0 0 0 * *continued on next page ** M08 -046 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 503 577 -8859 Phone: 940 891 -0729 Expiration Date: 02/12/2010 M08 -046 04/30/2008 10/27/2008 Fees Collected: $305.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 04 -30 -2008 Permit Center Authorized Signature: I hereby certify that I have read and e ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied t , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or thq/performance9f�vc�i5'7 I ftm authorized to sign and obtain this mechanical permit. Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: MO8 -046 Issue Date: 04/30/2008 Permit Expires On: 10/27/2008 Date: cctlaxDP Date: 1 /73 0- 0 Print Name: a ✓L P Ul � r � This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -046 Printed: 04 -30 -2008 Parcel No.: 6364200010 Address: 846 SOUTHCENTER MALL TUKW Suite No: Tenant: FOSSIL 1: ** *BUILDING DEPARTMENT CONDPI'IONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 10: ** *FARE DEPARTMENT CONDITIONS * ** • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS • Permit Number: M08 - 046 Status: ISSUED Applied Date: 02/19/2008 Issue Date: 04/30/2008 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond =10/06 M08 -046 Printed: 04 -30 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -046 Printed: 04 -30 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: C Le-r doc: Cond -10/06 M08 -046 Date: 3a `(a ordinances governing or local laws regulating Printed: 04 -30 -2008 Name Mailing Address:g E -Mail Address: JC, ` YVZ.` Company Name: Mailing Address: Mailing Address: Company Name: Mailing Address: Contact Person: E -Mail Address: CITY OF TUKWIL' Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Site Address: �g �;,ti '� Cl..0 cur Tenant Name: Property Owners Name: pt,,,}sf'c'j L,, Mailing Address: I (D Contact Person: E -Mail Address: Contractor Registration Number: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Flak: �. 4u- O: \ApplicationsWonns-Applications On Line \3 -2006 - Permit Application.doc Revised. 9 -2006 bh Company Name: r L1[ , j . �I id tA)s Aoc,Ir City lc '/So ?D44 SiJf� Building Pei —t No. Mechanical Permit `No. PlunibinglGas Pet it Na Public Works Permit No. Projec No. King Co Assessor's Tax No.: co d --001-0 Suite Number: New Tenant: Floor: .... Yes E ..No State (.) %.. Zip ay Te ephone: Sh� j 77 ; 59 ec� q1 213 City State Zip 6, l Fax Number: '( ° 2P1(4, (c) O City Day Telephone: Fax Number: Expiration Date: State Zip ST LC LALS W) Q 03 14 City State Zip Contact Person: Day Telephone: 31 4J5 2400 E -Mail Address: Fax Number: 3 4 4.15 ' 2-300 City Day Telephone: Fax Number: State Zip Page 1 of 6 PUBLIC WORKS PERMIT INM'RMATION - 206-433-0179 of Work (please provide detailed information): Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate FINANCE INFORMATION Water Meter Refund/Billing: Name: Mailing Address: Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimateaoFieet. Water District ❑ ...Tukwila 0... Water District #125 ❑ ...Water Availability Provided ❑• ❑... Septic System: ❑ On -site Septic System — For on -site septa stem, provide 2 copies of a curr it septic design approved by King County Health Department. er Submitted with Application (mark boxes which ° s ply): ❑ ...Civil Plans (Maximum Paper Size - 22" x 3 ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Ease t(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way _ ❑ ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ... Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backfl ow Prevention - Fire Protect Irrigation Domestic ; ater ValVue ❑ .. Renton wer Availability Provided Q:\ApplicationsWorms- Applications On Line'3 -2006 - Permit Application.doc Revised: 9 -2006 bh . Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line ❑ .. Highline ❑ t /Geotechnical Report ❑'.. Maintenance Agreement(s) ❑ .. Right -of -way Use - Profit for less than 72 hours .. Right -of -way Use — Potential Disturbance ❑ .. ❑..Sto rk in Flood Zone Drainage ❑ ...Permanent Water Meter Size. WO # ❑ ...Temporary Water Meter Si WO # ❑ ...Water Only Meter Size WO # ❑ ... Deduct Wate eter Size ❑ ...Sewer Main Extension .. Public Private ❑ ...Water Main Extension Public Private Fire Line Size at Property Line ❑...Water ❑...Sewer Monthly Service Billing to: Name: Mailing Address: Number of Public Fire Hydrant(s) ❑ ...Sewage Treatment Day Telephone: City Day Telephone: City ...Renton ❑ ...Seattle ❑ ... Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding State Zip State Zip Page 3 of 6 RECEIPT NO: R08 -01495 User ID: 1165 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http. //www.ci.tukwila.wa.us Initials: JEM Payment Date: 05/06/2008 Payee: ROYAL SEAL CONSTRUCTION, INC. SET ID: 0506 SET NAME: FOSSIL D08 -092 60.00 EL08 -162 58.00 M0.8 -046 60.00 TOTAL: 178.00 TRANSACTION LIST: Type Method Description Amount Payment Check 7766 178.00 TOTAL: 178.00 ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES SET RECEIPT Total Payment: 178.00 Account Code Current Pmts 000.322.101.00.0 58.00 000.322.102.00.0 60.00 000/345.830 60.00 TOTAL: 178.00 2061 05/06 9711 TOTAL 178.00 Parcel No.: 6364200010 Address: 846 SOUTHCENTER MALL TUKW Suite No: Applicant: FOSSIL Receipt No.: R08 -01422 Initials: JEM User ID: 1165 Payee: EUGENE PRESTON CLARK JR ACCOUNT ITEM LIST: Description doc: Receiot -06 MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us TRANSACTION LIST: Type Method Descriptio Amount Payment Check 904 244.00 RECEIPT Account Code Current Pmts 000.322.102.00.0 244.00 Total: $244.00 Permit Number: M08 -046 Status: APPROVED Applied Date: 02/19/2008 Issue Date: Payment Amount: $244.00 Payment Date: 04/30/2008 11:10 AM Balance: $0.00 1807 04/30 9711 TOTAL 244.00 Printed: 04 -30 -2008 n or•erme no RECEIPT NO: R08 -00467 SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www. ci. tukwila. wa. us Initials: JEM Payment Date: 02/19/2008 User ID: 1165 Payee: PRECISION PERMIT SERVICE SET ID: 0219 SET NAME: FOSSIL D08 -092 537.55 EL08 -162 69.70 M0.8 ; 046 61.00 PG08 -050 26.00 TOTAL: 694.25 TRANSACTION LIST: Type Method Description Amount Payment Check 5508 ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Total Payment: 694.25 694.25 694.25 Account Code Current Pmts 000.345.832.00.0 69.70 000/345.830 624.55 TOTAL: 694.25 :'97 02/19 9710 TOTAL. 2863.63 Project: Type of Inspection: Address: GG \\ ' JO r\b.\\ Date Called: Special Instructions: Date Wanted: 7 . - 1-* Oft a.m. p.m. Requester: Phone N c9y0 - S99 r. Inspector: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Mot- 0 PERMIT NO. I '"'"' (206)431 -3670 ®Approved per applicable codes. Corrections required prior to approval. COMMENTS: \ C Date: ^ �r ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ti Project: poSs r I Type of Inspection: Sr? o Si.,ed4 1m.4r1 Address: /ISO MAIL L Date Called: Special Instructions: Date Wanted: 7 r7- / of a.m. p.m. Requester: Phone 6-319-900 r s Mot - oa INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Vf- 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 IN Approved per applicable codes. Corrections required prior to approval. COMMENTS: V AV -I Re 4- -- Aa Sc ho — passwd Se 14 Date: ZieR E] $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: h..ra... xea�wrr.4ef COMMENTS: Type of Inspection: Address: L'\C.,. � J j - \c. ‘\ c co.i►r J e.- t r ,I c.. \ C F c_c\ Al. L -\r Date Wanted: 7 • ' • C' crr \V 4t C .o --7k e" & .Ac Phone l54'+0- '2Sqc, 9 0 r_e. C- CV. \A. a A A %•A • Project: ; Type of Inspection: Address: L'\C.,. � J j - \c. ‘\ Date Called: Special Instructions: Date Wanted: 7 • ' • C' crr a.m. P.m. Requester: Phone l54'+0- '2Sqc, 9 0 y hc% • C ►A( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300%SOuthcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 El Approved per applicable codes. ® Corrections required prior to approval. Inspector: z �s Date: —i • 01 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: Project: 1A \ Type of I pection: , 4\C\ `/ Address: Date Cal ed: Special Ins ructions: Date Wanted: -•°I , \ • a.m. 0% p.m. Requester: Phone 1/0 _ CI - 941140 F INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TU BUILDING DIVISION R INSPECTION NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Approved per applicable codes. Inspector: COMMENTS: (— Pr (2.4 Woo 'c(TNJG\ (' NN--0 _t \ \& \ (k & k A` C4 —"L' C cA.AS Corrections required prior to approval. Date: El $60.00 REINSPECTION FEE REQU RED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. '9• ti Projt: S ' / Type of Inspection f ti,/ rioal Ad ress Date Called: Special Instructions: Date Wanted: 6_ 3o-p£s Requester: Phone No: qYo 3 / r / lio 3 INSPECTION NO. Approved per applicable codes. INSPECTION RECORD - Retain a copy with permit 1 , • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 COMMENTS: 1 c o 1 ft/a le° IDate //sokG, Corrections required prior to approval. 0 $60. EINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid . t 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: Project: Typ of Inspection: �' Address: S� \ Cp l \\ Date Called: Special Instructions: \ Date Wanted: _ Co • Z ~ J • 0% a.m. p.m. Requester: Phone i VS - Zl.v 1 INSPECTION NO. r Approved per applicable codes. INSPECTION RECORD Retain a copy with permit fA0b` \Co PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 C orr ctions required prior to approval. COMMENTS: oar Inspector: $58.00 REINSPECTION FEE REQUIRED. Prior to inss`ection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call thefschedule reinspection. Date: Receipt No.: Date: COMMENTS: PN Type of Inspection. /� N 1 :n rba g 4..d IL, $ lig,/ 1 c i eiteft Date Called: t INI -tG DK /214., S i . ,., ri, /G,..- Special Instructions: Date Wanted: s /2/o i a.m. ` Requester: Phone No: 9450 eby, f Project:D55 J. Type of Inspection. /� Address: 3v4 Date Called: Special Instructions: Date Wanted: s /2/o i a.m. ` Requester: Phone No: 9450 eby, f INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 El Approved per applicable codes. Corrections required prior to approval. Inspector: Date: $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: ACTIVITY NUMBER: M08 -046 PROJECT NAME: FOSSIL SITE ADDRESS: 846 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # DATE: 04 -30 -08 Response to Incomplete Letter #_ X Revision # 'I After Permit Issued DEPARTMENTS: ��D B iIii D i Ion Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete V Comments: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 Fire Ilrevention Structural Incomplete ❑ DUE DATE: 05 -01 -08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: Structural Review Required ❑ No further Review Required DATE: DUE DATE: 05-29-08 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -046 DATE: 02 -19 -08 PROJECT NAME: FOSSIL SITE ADDRESS: 846 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil Division Public Works ❑ D DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Structural Incomplete n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 APPROVALS OR CORRECTIONS: 6(I C 2 'ZZ '0� Fire Prevention n Planning Division Permit Coordinator DUE DATE: 02-21 -08 Not Applicable ❑ No further Review Required DATE: Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: n n DUE DATE: 03-20-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 4 Summary of Revision: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.cLtukwila.wa.us Plan Check/Permit Number: ry Steven M. Mullet, Mayor Steve Lancaster, Director ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # i, t after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: c:3 Project Address: 4 2)` - r to , Contact Person: � h 1 r l c — , C A ✓ z � - y Phone Number: 9 40- - °i * k o RECEIVED LA PERMr? Sheet Number(s): (V\ 2 . "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: [_ Entered in Permits Plus on 'T -'f \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: License Information License EINSTMW924CK Licensee Name EINSTEIN MECHANICAL OF WA Licensee Type CONSTRUCTION CONTRACTOR UBI 602799271 Ind. Ins. Account Id #1 Business Type INDIVIDUAL Address 1 315 E HICKORY ST 'Address 2 City AUBREY County OUT OF STATE State TX Zip 76227 Phone 9408910729 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/12 /2008 Expiration Date 2/12 /2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #1 RLI INS CO LSM0044540 02/04/2008 Until Cancelled $12,000.00 02/12/2008 Business Owner Information Name Role Effective Date Expiration Date FISCHER, SHANE L OWNER 02/12/2008 Look Up a Contractor, Electr or Plumber License Detail Washington State Department of Labor and Industries GeneraUSpecialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Savings Information • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= EINSTMW924CK 04/30/2008 PROJECT ADDRESS: SOUTHCENTER MALL 846 SOUTHECENTER PKWY LEVEL 1 of 3 SEATTLE, WA 98188 TENANT KEY PLAN OCCUPANCY BREAKDOWN FOSSIL LEVEL 1 of 3 SPACE #1150 1347 S.F. SHELL : SHELL OCCUPANCY: CONSTRUCTION TYPE: FIRE SPRINKLERS: TENANT SPACE: TENANT OCCUPANCY: CONSTRUCTION TYPE: FIRE SPRINKLERS: NET SALES AREA STOCK ROOM : TOTAL AREA: EXITS: APPLICABLE CODES BUILDING CODE MECHANICAL CODE PLUMBING CODE ELECTRICAL CODE ENERGY CODE AIR QUALITY CODE FIRE CODE PROJECT DATA M (MERCANTILE) TYPE 2 -B FULLY SPRINKLERED M (MERCANTILE) TYPE 2 -B _ EGRESS PATH 70' -0" TRAVEL DISTANCE 1 REQUIRED, 1 PROVIDED SALES AREA 1,221 S.F. / 30 = 40 OCCUPANTS STOCK ROOM 257 S.F. / 300 = 1 OCCUPANT Permit No. Mar review approval is subject to errors and orntsicrs Approval of construction documents does not authorize the violation o =t y adopted code or ice. r :r r¢ of approved - . py d conditions is a nt; icc.ti: Js By Date: S _•.. YES 1,221 S.F. / 30 = 40 OCCUPANTS 257 S.F. / 300 = 1 OCCUPANT 1478 S.F. = 41 OCCUPANTS TOTAL OCCUPANT LOAD = 41 OCCUPANTS TOTAL =1,478 S.F. TENANT IMPROVEMENT FOR SIL ACCESSORY STORE SOUTHCENTER MALL 846 SOUTHCENTER PKWY SEATTLE, WA 98188 RLE COPY City of Tukwila BUILDING DIVISION 2006 INTERNATIONAL BUILDING CODE W/ WA STATE AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE W/ WA STATE AMENDMENTS 2006 UNIFORM PLUMBING CODE W/ WA STATE AMENDMENTS 2005 NATIONAL ELECTRIC CODE 2006 WA STATE ENERGY CODE 2006 WA STATE INDOR AIR QUAILITY 2006 INTERNATIONAL FIRE CODE W/ WA STATE AMENDMENTS OWNER ARCHITECT LANDLORD REVISIONS No Changes shall be made to the f scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ' and may include additional plan review Tees FOSSIL, INC. 2280 NORTH GREENVILLE AVE. RICHARDSON, TEXAS 75082 TEL (972) 699 -9363 ARCVISION, INC. 1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146 PHONE (314) 415 -2400 FAX (314) 415 -2300 CONTACT: BOB WARDLAW www.arcv.com *CONTACT PROJECT MANAGER FOR ANY DESIGN QUESTIONS FOSSIL, INC. 2280 NORTH GREENVILLE AVE. RICHARDSON, TEXAS 75082 PHONE: (972) 889 -5816 CONTACT: PETE ITALIANO pitaliano @fossil.com PROJECT MANAGER ARCVISION, INC. 1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146 PHONE: (314) 415 -2400 FAX: (314) 415 -2300 CONTACT: DEAN DEORNELLAS MECHANICAL /PLUMBING AND ELECTRICAL WESTFIELD 11601 WILSHIRE BLVD. LOS ANGELES, CA 90025 PHONE: (310) 478 -4456 MALL OPERATIONS MANAGER: MARSHA PEDDICORD PHONE: (818) 402 -8923 CITY OF TUKWILA BUILDING DIVISION 6300 SOUTHCENTER BLVD. #100 TUKWILA, WA 98188 PHONE (206) 431 -3670 http:// www. ci .tukwilawa.us /dcd /dcdbuild.htm BUILDING DEPARTMENT ARCHITECTURAL A -0.0 A -0.1 A -0.2 A -0.3 A -1.1 A -1.2 A -1.3 A -1.4 A -1.5 A -2.0 A -2.1 A -2 2 COVER SHEET GENERAL NOTES AND LEGENDS SPECIFICATIONS SPECIFICATIONS FLOOR PLAN FLOOR COVERING PLAN REFLECTED CEILING PLAN CEILING DETAILS MERCHANDISE FIXTURE PLAN STOREFRONT PLAN AND ELEVATION STOREFRONT SECTIONS S OREFRONT DE A I A -2.3 SOFFIT FRAMING PLAN AND DETAILS 3.0 ER OR ELEVATI • N / ' WALL SCHEDULES A -4.0 ELECTRICAL E1.1 LIGHTING PLAN E1.2 POWER PLAN E1.3 ELECTRICAL SCHEDULES AND DETAILS E1.4 ELECTRIAL SPECIFICATIONS MECHANICAL M1.1 H.V.A.C. PLAN M2.1 H.V.A.C. SCHEDULES AND DETAILS M3.1 H.V.A.C. SPECIFICATIONS PLUMBING INDEX TO DRAWINGS REVISION NO VICINITY MAP REVISED 04/24/08 04/24/08 04/24/08 04/24/08 04/02/08 04/24/08 04/24/08 04/24/08 04/24/08 04/24/08 04/24/08 04/24/08 04/24/08 �'VIEV ED FOR P1.1 PLUMBING PLAN CC DE COMPLIANCE APPROVED P2.1 PL4JMBING SCHEDULES AND DETAILS MAY - 5 2008 r ty Of Tukwila D ING D:. : .1 MOSO4 AO.O PROJECT NO. DATE: DRAWN BY: SCALE. FILE: O7M1 I I GROSS AREA SALES STOCK TOILET REVISIONS; 4/24/OS OWNER/LANDLORD SHEET TITLE: COVER SHEET III o � m u_ z w V) N W da o a o z z � i W ua w ' cfl z W APR 3 0 200 LU ,ER M IT C EN T Eh o cO N N 0 - 1M111 I /25 /OE LL.. AS NOTE I - AO.O.DWG- 1,478 S.F 1,221 S.F 1 12 S.F 65 S.F co Q � aO a co cc w W F� Q z W O W O =J Hu h Q W CO C (D O co g FOSSIL (SPACE #1150) SOUTHGENTER MALL 846 SOUTHGENTER MALL TUKWILA, WA. Q8188 1,478 SQUARE FEt t LOAD COMPONENT SUMMARY DETAILS SENSIBLE LOAD COMPONENT HEAT GAIN LATENT HEAT HEAT GAIN LOSS SOLAR LOADS WALL TRANSMISSION - - --- ROOF TRANSMISSION GLASS TRANSMISSION DOOR TRANSMISSION LIGHTING (WATTS) 3,824 6,621 OTHER ELECTRIC (WATTS) 675 2,OIq PEOPLE 21 4,335 INFILTRATION - - --- MISCELLANEOUS - ---- 6,584 SLAB 1,418 Scq.Ft. PULLDOWWWARM -UP 6,814 SAFETY FACTOR 20%/20%/20% 3,g13 VENTILATION SUPPLY FAN LOAD 1,400 GPM 1,556 PLENUM LOAD - LIGHTS 30% 3,41 PLENUM LOAD - ROOF PLENUM LOAD - WALLS — -- 5,555 -- - -- -- - -- -- - -- - - -- 1,101 ---- -- TOTAL LOADS 35,826 6,642 0 DESIGN GOND ITIONS WEATHER SYSTEM THERMOSTAT LOCATION: TUKWILA, WASHINGTON VAV BOX ELEVATION = 138.0 FT SUPPLY AIR - 55.0 DEG. F SUMMER DB = 85.0 DES. F 1,400 CFM SUMMER NB = 65.0 DEG. FF START - 8:00 WINTER DB = 23.0 DEG. F DURATION - 14 HRS COOL (OGG) - 15.0 DEG. F GOOL (UNOGG.) - 85.0 DEG. F HEATING - 10.0 DEG. F A. EXISTING CONDITIONS ARE BASED ON "AS- BUILT" DRAWINGS PROVIDED BY THE TENANT AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE TENANT. B. DISPOSE OF ALL EQUIPMENT NOT REUSED AS A PART OF THE NEW WORK AS DIRECTED BY THE OWNER. G. MECHANICAL CONTRACTOR TO INSTALL HVAC DUCTWORK PER MALL CRITERIA. D. DUCT HANGERS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE. E. MECHANICAL CONTRACTOR SHALL FIELD COORDINATE WITH FL FGTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS. F. MECHANICAL CONTRACTOR SHALL PROVIDE TENANT WITH A WRITTEN TWO (2) YEAR MANUFACTURING WARRANTY ON ALL HVAG EQUIPMENT PROVIDED AND / OR INSTALLED THE WARRANTY SHALL INCLUDE ALL LABOR, MATERIALS AND THREE (3) ROUTINE SERVICES WITH FILTER CHANGES DURING A ONE (I) YEAR PERIOD. G. AT THE COMPLETION OF CONSTRUCTION, AN INDEPENDENT AABC OR NEBB CERTIFIED AIR BALANCE REPORT SHAI 1.15E SUBMITTED TO THE TENANT AND LANDLORD. H. VERIFY ALL EXISTING CONDITIONS IN THE FIELD BEFORE BID. NOTIFY ARCHITECT IMMEDIATELY IF CONFLICT EXISTS. CONTRACTOR 15 RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION/CONSTRUCTION OF NEW WORK. I. ALL DUCT CONNECTIONS TO HVAG EQUIPMENT MUST BE MADE WITH FLEXIBLE CONNECTORS. J. ALL DUCT DIMENSIONS SHALL BE INSIDE DIMENSIONS. ALL DUCTWORK (EXCEPT EXHAUST DUCTWORK) SHALL BE LINED WITH I-- I/2" ACOUSTICAL DUCT LINER OR WRAPPED WITH I -1/2" THICK FIRE RETARDANT FIBERGLASS WITH A REINFORCED ALUMINUM FOIL JACKET AND SHALL BE APPROVED FOR USE BY SMAGNA. K. COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR. VERIFY ALL CLEARANCES BEFORE STARTING WORK. H.V.A.C. GENERAL NOTES H.V.A.C. LOAD CALCULATIONS 5 L. PROVIDE ALL NECESSARY WIRING, RELAYS, DETECTORS, COMPONENTS, ETC., FOR FIRE ALARM SYSTEM IN I t - LOCK. VERIFY WITH MALL PERSONNEL BEFORE BID. M. THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. N. PARTS OF BUILDING SYSTEMS THAT FALL INTO LEASE LINE SHALL REMAIN UNDISTURBED. 0. ALL ROOFING WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT TENANT G.G.'S EXPENSE. P. DO NOT ATTACH ANYTHING TO DECK ABOVE. ATTACH TO STRUCTURE (I.e. BEAMS, JOISTS) ONLY. Q. TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL UTILITY RUNS AND /OR OTHER IMPROVEMENTS LOCATED ON THE PREMISES. TENANT'S CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL COSTS RELATING TO THE RELOCATION OF, DAMAGE TO, REPAIR OF ANY EXISTING UTILITY RUNS AND /OR IMPROVEMENTS WHICH ARE DAMAGED AS A RESULT OF TENANTS WORK IN OR AROUND THE PREMISES. R. TENANT'S G.G. MUST COORDINATE AND CONFIRM ALL VAV BOX EQUIPMENT LOCATIONS PRIOR TO BID. L.L. APPROVED FIELD DECISIONS WILL SUPERSEDE THESE PLANS. O NEW TRANE (OR EQUAL) MODEL VAV BOX, PROVIDED AND INSTALLED BY HVAG CONTRACTOR. CONNECT TO LANDLORD'S EXISTING SUPPLY AIR DUCT. FIELD VERIFY EXACT LOCATION AND SIZE. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. �2 PROVIDE AND INSTALL A VAV COMPATIBLE THERMOSTAT WITH SUB -BASE AND LOCKING LUCITE COVER. COORDINATE WITH ELECTRICAL CONTRACTOR. MOUNTING HEIGHT 48" A.F.F. TURN KEY OVER TO STORE MANAGER • NEW GROAN (OR EQUAL) MODEL #SqO SERIES TOILET EXHAUST FAN. 40 CFM, 15 SONES, 120/1/60, .5 AMPS, 4" DIA. EXHAUST DUCT. HOUSING 15's" h x 41/4" IN x 4 d. COORDINATE WITH ELECTRICAL CONTRACTOR. ROUTE NEW 4" RD. TOILET EXHAUST DUCT TO LANDLORD'S EXISTING TOILET EXHAUST DUCT STUB -IN. FIELD VERIFY EXACT SIGs; AND LOCATION. @ FLEXIBLE DUCT. MAXIMUM LENGTH 5' -0" (TYPICAL). PROVIDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMAGNA (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RUNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZE. LANDLORD'S SPRINKLER SYSTEM POINT OF CONNECTION. FIELD VERIFY EXACT SIZE AND LOCATION. © SPRINKLER HEAD. PROVIDE NEW/RELOGATE EXISTING AS REQUIRED. COORDINATE EXACT LOCATION(S) WITH NEW LIGHT FIXTURES. MODIFY SUPPLY PIPING AS REQUIRED. LANDLORD'S EXISTING SUPPLY AIR DUCT MAIN. FIELD VERIFY EXACT LOCATION AND SIZE. ® LANDLORD'S EXISTING TOILET EXHAUST DUCT. FIELD VERIFY EXACT LOCATION AND SIZE. ® NEW TRANSFER OPENING /GRILLE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR (TYP.). COORDINATE EXACT LOCATION, SIZE, AND QUANTITY WITH LANDLORD AND WITH GENERAL CONTRACTOR. FIELD VERIFY EXISTING CONDITIONS. 10 NEW 2" THICK EXTERNAL INSULATION 15 - 3.0 LB /CU.FT. LINER, MINERAL OR GLASS FIBER BLANKET WITH MINIMUM VALUE OF R -1 "LOW PRESSURE" SUPPLY AIR DUCT INSTALLED BY HVAC CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. ADJUST DUCT LAYOUT PER ACTUAL UNIT LOCATION. VERIFY IN FIELD. 1 1 FIRE EXTINGUIGI IER FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. COORDINATE TYPE, QUANTITY AND LOGATION(S) WITH LANDLORD AND LOCAL FIRE MARSHAL. 12 SUPPLY 4 INSTALL SPRINKLER HEAD ON TOILET ROOM CEILING. COORDINATE EXACT LOCATION WITH CEILING GRID AND LIGHT FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. 13 PROVIDE AND INSTALL TURNING VANES AT ALL SQUARE/RECTANGULAR DUCT ELBOWS (TYPICAL). 14 PROVIDE AND INSTALL VOLUME DAMPER AT BRANCH DUCT CONNECTION TO DIFFUSER (TYPICAL). 15 ENSURE TOILET ROOM DOOR IS UNDERCUT 3/4" (MIN,) TO FACILITATE AIR FLOW. COORDINATE WITH GENERAL CONTRACTOR. 4 H.V.A.C. PLAN KEYED NOTES afr Y H.V.A.C. PLAN SCALE: 1/4" = 1' -0" 3 12/S EXISTING DUCTWORK IN/ LABEL -=3-FD I/4/AD -c=mVD 0 SD BOO GFM 14/6 D -3 24/14 G -I • 0 Q LEGEND DUCTWORK W/ LABEL FIRE DAMPER WITH ACCESS DOOR VOLUME DAMPER THERMOSTAT W/ PLASTIC LOCKING COVER. MOUNT @ 60" A.F.F. REMOTE SENSOR SMOKE DID I tCTOR SUPPLY DIFFUSER LABEL RETURN GRILLE LABEL NEW TO EXISTING SPRINKLER HEAD -FIRE EXTINGUISHER H.V.A.C. LEGEND . E City Of Tupih BUILDING '. tt, =RF= t II 1 li n I >• €t € I II pis. I !Vt2 IMPINPF ► �'w 245 - - - -- -� Nw! MIK 1111 11111, 1111111 .art (`. t��� h .1i 11�� to t.= , ��A wariatinie °IL 114111111 11 1441W PWI I o kik 1111111 \ REVIEWED FOR CODE COMPLIANCE APPROVED MAY . 5 2008 \ \ REVISION NO:j \ 09 0 \ \ \ 2 1 PROJECT NO. 071\1111 DATE 1/25/0e DRAWN BY: JH!A SCALE: AS NOTED FILE: O7M1III- M -I.I.L V1E GROSS AREA SALES STOCK TOILET REVISIONS: 4/24/08 OWNER/LANDLORD SHEET TITLE: H.V.A.C. PLAN O U- I— Z W w 0 0 I— z Z W I— APR 3 0 2008 PERMIT CENT�h 111 0 a U W W U- 0 U7 m 0 I U Q N w LU ! 0 z O 0 T.) LEL >X ui • E 0 a a F 0_ M1.1 1,478 S.F 1,221 S.F IG2 S.F s5 S.F co co cc Vl cc w W Q z W W O W I i— I— O vl � cc �Y it 01__ HEATING- VENTILATING -AIR CONDITIONING SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SUPPLY STEAM (LOW PRESSURE_) STEAM (MEDIUM PRESSURE) STEAM (HIGH PRESSURE) I T AUTOMATIC CONTROL VALVE TOGA 818x18 24x24 3 26 4 AS -15 , `1 D -2 SUPPLY DUCT (5A) DUCT MTD, i>4 / / 51 PRESSURE REGULATING VALVE (PR /) // // RETURN CEILINS AG TILE RETURN OR EXHAUST RETURN FRESH AIR MOT (RA OR E 50 F 22 22 3 26 B - - - -f _ - /- -A/- -//--- CONDENSATE (LOW PRESSURE) CONDENSATE (MEDIUM PRESSURE) CONDENSATE (HIGH PRESSURE) n oR� SAFETY RELIEF VALVE BLOW OFF VALVE SOUND TRAP I sr I —NM— HOT WATER SUPPLY (HEATING) F AND T TRAP (GAP. St/HR) ►p # GEM SUPPLY REGISTER OR 6RJLLE (R OR 6) - - tIhBZ- - HOT WATER RETURN (HEATING) THERMOSTATIC TRAP I SIZE ® ETHYLENE GLYCOL SUPPLY 5.P. STATIC PRESSURE GF1 I REI JRN REGISTER OR GRILLE (R OR G) �- I SIZ 1 - -EC,- - ETHYLENE GLYCOL CIRCUIT SETTER FLOW CONTROL VALVE CFM FRESH AIR INTAKE (FA) GHII I ET? WATER SUPPLY AIR BLEEPER VALVE (RADIANT PANEL) I S IZE —GYG CHILLED HATER RETURN Q - -c - AIR ELIMINATOR \-f UN ROD CEILING DIFflJSER (`SUPPLY) S S PUUMP�ISSCHARGGE VACUUM --O AUTOMATIC BALANCING VALVE �, ROUND CEILING DIFFUSER (SUPPLY AND RETURN) HUMIDIFICATION LINE SOLENOID VALVE (REFRIGERANT) H __.,.^C) FUEL OIL SUPPLY THERMOSTATIC EXPANSION VALVE CRIE=R.) mei SQUARE CEILING DIFFUSER (SUPPLY) —FDA FUEL OIL RETURN BACK PRESSURE VALVE —rots (SUPPLY CEILING DIFFUSER (SUPPLY AND RETURN) - - FOV - - FUEL OIL VENT z SIGHT GLASS p GA5 LINE —,— PIPE OR ROUND DUCT RISER SQUARE CEILING DIFFUSER THREE WAY TI IP.OF' — 0 =I= LIQUID LINE FBI 0 FAN COIL UNIT AND MARY. RL REFRIGERANT SQUA2 Y GEILIN6 DIFFUSER TWO WA THROW R REFRIGERANT SUCTION LINE - r UH -I UNIT HEATER-PROPELLER TYPE $ MARK u ' l l l REFRIGERANT HOT GAS DI GFIARGE LINE AUTOMATIC DAMPER RD— CONDENSER WATER GUI -I CABINET UNIT HEATER $ MARK Jn ' W'_ GRAVITY DAMPER - -CR- - CONDENSER WATER RETURN FT -I may FIN TUBE, MARK ANP CAPACITY BOILER BLOW OFF FR D FIRE DAMPER —Btu -- UI CONVECTOR AND MARK Err --- EXHAUST STEAM ® UNIT VENTILATOR AND MARY. CONCENTRIC REDUCER BD BASEBOARD DIFFUSER r j ( ` ( REGTAN&ULAR DUCT FIRST FIGURE IS SIDE SHOWN J ECCENTRIC. REDUCER 0 HEATING RISER NUMBER ROUND DUCT: G GOLD R :RETURN --rill— UNION 1, V6 H b t STRAINER ( CANVAS CONNECTION EXHAUST FAN RISER NUMBER L. Q — - EXPANSION JOINT VOLUME DAMPER (ELEV AND PLAN) BR BASEBOARD RADIATION a� �_ J . 0 THERMOSTAT TURN VANES O REMOTE SENSOR gloom Ii T ERMOMETER EXTRACTOR Q PR15URE GAGE DIFFUSERS, GRILLES AND RESISTERS MARK SERVICE LOCATION GLG. TYPE MANUFAG. CATALOG NUMBER REMARKS D -I SUPPLY CEILING AG TILE TITUS TOGA 818x18 24x24 3 26 4 AS -15 17 "x14" D -2 SUPPLY DUCT MTD, - - --- TITUS BOO -RL 14 "x6" G - I RETURN CEILINS AG TILE TITUS 50 F 22 22 3 26 B NEIN VAV BOX SCHEDULE (VAV -I) MFR. MODEL NO. BASE UNIT WT. UNIT SIZE INLET SIZE OUTLET SIZE TOTAL GFM MINIMUM AIR GFM TRANE (O ER QUAL) VCCFI2 LBS 12 12" 17 "x14" 1,400 245 SCALE: NONE SCALE: NONE S TRAI\ cO% ELBOA 45k ELBOIA. S I I LAR SUPPLY OR RETUR\. / \YE (RECTA\.SULAR DUCT) RETUR\ PAIR BRANCH FITTI\f6 DUCTWORK DETAILS ROOF JOIST HANGER WIRE DUCT HANGER DETAIL CIO% FIVE EECTIOI\. ELBOA ROUND DUCTWORK DETAILS SCALE: NONE G O% BRA \ CH TAKE -OFF SFORMATIOI\ <J 3/4 1/2 D NO THROAT RADIUS SHEET MTL. DUCT HANGER RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS 45 THREE SEGTIO\ EL 3O A 45 BRANCH TAKE -OFF / -el— I5 OR LESS � FLOW EXFA \510 \. n THREE TURNING VANES GO% ELBOn. TAKE -OFF USE ONLY I N AREAS HERE SPACE 15 LIMITED SCALE: NONE VOLUME DAMPER LOCATED IN ACCESSIBLE LOCATION. PROVIDE ACCESS DOOR OR GABLE OPERATOR IF NOT ACCESSIBLE. SCALE: NONE CONTRACTION SHORT RADIUS FIBERGLASS INSULATION PER SPECIFICATIONS OPPOSED BLADE DAMPER AT DIFFUSER INSULATE DIFFUSER BACK AND SEAL WITH VAPOR BARRIER TAPE 6 MAX. OF 12 TO BRANCH CONNECTION UNLESS NOTED OTHERWISE FULL RADIUS FULL RADIUS ELBOIA1 TAKE -OFF ROOF JOIST HANGER WIRE 8 ROUND DUCT HANGER DETAIL ALVINIZED ICET METAL DUCT ' ■ni 7 TYP. DIFFUSER CONNECTION SHEET MTL. DUCT HANGER SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS SE RIGID GALVINIZED GO DEGREE ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES INSULATED FLEXIBLE DUCT (MIN. 2', MAX. S', NO MORE THAN ONE GO /e. BEND) TRANSITION FITTING AS REQUIRED NOTE: VERIFY WITH LANDLORD FOR TYPE OF ELECTRONIC CONTROLS REQUIRED. 6 SUPPLY AIR DIFFUSER 5 4 SCALE: NONE SCALE: NONE LANDLORD'S SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. I' -O" 1 IISV WIRING J -BOX BY ELECTRICAL CONTRACTOR J -BOX * THERMOSTAT WIRING ,--"" BY HVAG CONTRACTOR VAV BOX DETAIL FAN EXHAUST GRILLE CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB -IN OR NEW DUCT THROUGH ROOF. REFER TO KEYED NOTES. MEDIUM TO HIGH PRESSURE DUCT El EC DAMPER OPERATOR * FOLLOW MANUFACTURER'S WIRING DIAGRAM ROOM THERMOSTAT CE I L I NG BACKDRAFT DAMPER TOILET EXHAUST DETAIL HANGERS (TYP. OF 4) VAV BOX REVISION N0:1 1108 - 43 1 1 b REVIEWED F j R CODE COMPLIANCE APPROVED MAY - 5 2008 City Of Tukwila B ILDING DIIISION 2 CEAVpt AP R 3 0 2008 'ERMIr CENT L- PROJECT NO. DATE: DRAWN BY: SCALE: FILE O I 1 I --M2 . I .DING GROSS AREA SALES STOCK TOILET REVISIONS: / \ 4/24/OS OWNER/LANDLORD SHEET TITLE: H.V.A.C. SCHEDULES AND DETAILS IZ m CC 0 LU I- CC M2.1 07M111 1/25/08 JHIn AS NOTE 1,418 S.F 1,221 S.F I'I2 S.F 55 S.F c0 c0 � CC W W H Z 5 Z LU W UW U2 _ 1— I-- I— I D 0 < CD c0 FOSSIL (SPACE *1150) SOUTHGENTER MALL 846 50UTHGENTERR MALL TUKWILA, WA. 88188 1,478 SQUARE FEET LOAD COMPONENT SUMMARY DETAILS 51545115LE LOAD COMPONENT HEAT GAIN LATENT HEAT HEAT GAIN LOSS --- ----- ----- - -- -- SOLAR LOADS ---- - --- INALL TRANSMISSION ----- ---- ROOF TRANSMISSION ----- ---- - ----- - --- - -- ----- - - -- GLASS TRANSMISSION ----- DOOR TRANSMISSION --- LIGHTING (INATTS) 3 ,82g1 6 ,621 OTHER ELECTRIC (WATTS) 675 2p1 PEOPLE 21 4,335 INFILTRATION - - -- MISGEL_LANEOUS - --- 6,53 SLAB 1,478 Sq.Ft. - -- PULLDOWW/WARM -UP — 6,814 SAFETY FACTOR 20%/20 % /20% 3,113 ----- ---- ---- -- 5,555 w- --- ----- --- ---- -- - --- - -- ---- 1,101 ----- - -- ----- — - - --- ----- VENTILATION - -- SUPPLY FAN LOAD 1,400 CFM 1,556 PLENUM LOAD - LIGHTS 30% 3,114 ROOF --- -- - - -- .. - -.-- -- PLENUM LOAD - -- PLENUM LOAD - WALLS ---- ----- ----- - TOTAL LOADS 35,826 6,642 0 DESIGN CONDITIONS WEATHER SYSTEM THERMOSTAT LOCATION: TUKWILA, WASHINGTON VAV BOX ELEVATION = 138.0 FT SUPPLY AIR - a.O DEG. F SUMMER DB = 85.0 DEG. F 1,400 GFM SUMMER WS = 65.0 DEG. FF START - 8:00 WINTER DB = 25.0 DEG. F DURATION - 14 HRS COOL (OCG.) - 75.0 DEG. F COOL (UNOGG.) - 85.0 DEG. F HEATING - 10.0 DEG. F A. EXISTING CONDITIONS ARE BASED ON °AS- BUILT DRAWINGS PROVIDED BY THE TENANT AND LIMITED FIELD VERIFICATION. CONTRACTOR SHALL ADJUST TO ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE TENANT. B. DISPOSE OF ALL EQUIPMENT NOT REUSED AS A PART OF THE NEW WORK AS DIRECTED BY THE OWNER. G. MECHANICAL CONTRACTOR TO INSTALL HVAG DUCTWORK FM MALL CRITERIA. D. DUCT HANGERS SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE. E. MECHANICAL CONTRACTOR SHALL FIELD COORDINATE WITH ELECTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS. F. MECHANICAL CONTRACTOR SHALL PROVIDE TENANT WITH A WRITTEN TWO (2) YEAR MANUFACTURING WARRANTY ON ALL HVAC EQUIPMENT PROVIDED AND / OR INSTALLED. THE WARRANTY SHALL INCLUDE ALL LABOR, MATERIALS AND THREE (3) ROUTINE SERVICES WITH FILTER CHANGES DURING A ONE (I) YEAR PERIOD. G. AT THE COMPLETION OF CONSTRUCTION, AN INDEPENDENT AABC OR NEBB CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED TO THE TENANT AND LANDLORD. H. VERIFY ALL EXISTING CONDITIONS IN THE FIELD BEFORE 5112. NOTIFY ARCHITECT IMMEDIATELY IF CONFLICT EXISTS. CONTRACTOR IS RESPONSIBLE TO DEMOLISH ALL EXISTING AS REQUIRED FOR INSTALLATION /CONSTRUCTION OF NEW WORK. I. ALL DUCT CONNECTIONS TO HVAC EQUIPMENT MUST 5E MADE WITH FLEXIBLE CONNECTORS. J. ALL DUCT DIMENSIONS SHALL BE INSIDE DIMENSIONS. ALL DUCTWORK (EXCEPT EXHAUST DUCTWORK) SHALL BE LINED WITH I- I/2" ACOUSTICAL DUCT LINER OR WRAPPED WITH I -I/2" THICK FIRE RETARDANT FIBER 'LASS WITH A REINFORCED ALUMINUM FOIL .JACKET AND SHALL BE APPROVED FOR USE BY SMACNA. K. COORDINATE DUCT ROUTING AND HEIGHTS WITH GENERAL CONTRACTOR VERIFY ALL CLEARANCES BEFORE STARTING WORK. H.V.A.C. GENERAL NOTES H.V.A.C. LOAD CALCULATIONS 5 L. PROVIDE ALL NECESSARY WIRING, RELAYS, DETECTORS, COMPONENTS, ETC., FOR FIRE ALARM SYSTEM INTERLOCK. VERIFY WITH MALL PERSONNEL BEFORE BID. M. THE CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT CRITERIA MANUAL. TENANT CRITERIA MANUAL SHALL BE INCLUDED IN THIS CONTRACT. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH LANDLORD REQUIREMENTS AT NO EXTRA COST TO THE TENANT. N. PARTS OF BUILDING SYSTEMS THAT FALL INTO LEASE LINE SHALL REMAIN UNDISTURBED. 0. AL ROOFING. WORK SHALL BE PERFORMED BY LANDLORD'S APPROVED ROOFING CONTRACTOR AT TENANT G.G.'S EXPENSE. P. DO NOT ATTACH ANYTHING TO DECK ABOVE. ATTACH TO STRUCTURE (La. BEAMS, JOISTS) ONLY. Q. TENANT'S CONTRACTOR SHALL 15E RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL UTILITY RUNS AND /OR OTHER IMPROVEMENTS LOCATED ON THE PREMISES. TENANT'S CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ALL COSTS RELATING TO THE RELOCATION OF, DAMAGE TO, REPAIR OF ANY EXISTING UTILITY RUNS AND /OR IMPROVEMENTS WHICH ARE DAMAGED AS A RESULT OF TENANTS WORK IN OR AROUND THE PREMISES. R TENANT'S 6.0. MUST COORDINATE AND CONFIRM ALL VAV BOX EQUIPMENT LOCATIONS PRIOR TO BID. L.L. APPROVED FIELD DECISIONS WILL SUPERSEDE THESE PLANS. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined'C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) ® NEW TRANE (OR EQUAL) MODEL VAV BOX, PROVIDED AND INSTALLED BY HVAC CONTRACTOR CONNECT TO LANDLORDS EXISTING SUPPLY AIR DUCT. FIELD VERIFY EXACT LOCATION AND SIZE. REFER TO SCHEDULE FOR ADDITIONAL INFORMATION AND CFM. ® PROVIDE AND INSTALL A VAV COMPATIBLE THERMOSTAT WITH SUB -BASE AND LOCKING LUCITE COVER.. COORDINATE WITH ELECTRICAL CONTRACTOR MOUNTING HEIGHT 48" A.F.F. TURN KEY OVER TO STORE MANAGER ® NEW BROAN (OR EQUAL.) MODEL 145'O SERIES TOILET EXHAUST FAN. GO CFM, 1.5 SONES, I20/I /6O, 5 AMPS, 4" DIA. EXHAUST DUCT. HOUSING Tb" h x l V4°w x 6 11/2" d. COORDINATE WITH ELECTRICAL CONTRACTOR ROUTE NEW 4 RD. TOILET EXHAUST DUCT TO LANDLORDS EXISTING TOILET EXHAUST DUCT STUB -IN. FIELD VERIFY EXACT SIZE AND LOCATION. ® FLEXIBLE DUCT. MAXIMUM LENGTH 5'-O" (TYPICAL). PROVIDE SMOOTH TRANSITION AND PROPER BUPPORTS PER SMACNA (TYPICAL). USE FLEXIBLE DUCT FOR FINAL RJNOUT TO DIFFUSER ONLY. REFER TO SCHEDULE FOR FLEXIBLE DUCT SIZE. ® LANDLORD'S SPRINKLER SYSTEM POINT OF CONNECTION. FIELD VERIFY EXACT SIZE AND LOCATION. ® SPRINKLER HEAD. PROVIDE NEW/RELOCATE EXISTING AS REQUIRED. COORDINATE EXACT LOGATION(5) WITH NEW LIGHT FIXTURES. MODIFY SUPPLY PIPING, AS REQUIRED. ®7 LANDLORD'S EXISTING SUPPLY AIR DUCT MAIN. FIELD VERIFY EXACT LOCATION AND SIZE. ® LANDLORD'S EXISTING, TOILET EXHAUST DUCT. FIELD VERIFY EXACT LOCATION AND SIZE. ® NEW TRANSFER OPENING /GRILLE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR (YP.). COORDINATE EXACT LOCATION, SIZE, AND QUANTITY WITH LANDLORD AND WITH GENERAL CONTRACTOR FIELD VERIFY EXISTING CONDITIONS. 10 NEW 2° THICK EXTERNAL INSULATION 1.5 - 3.0 LB /GU.FT. LINER, MINERAL OR GLASS FIBER BLANKET WITH MINIMUM VALUE OF R -7 "LOW PRESSURE" SUPPLY AIR DUCT INSTALLED' BY HVAC CONTRACTOR. PROVIDE TRANSITIONS AS REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL. AIR PATH DIMENSIONS. ADJJST DUCT LAYOUT PER ACTUAL UNIT LOCATION. VERIFY IN FIELD. 11 FIRE EXTINGUISHER FURNISHED AND INSTAL I PO 5Y GENERAL CONTRACTOR. COORDINATE TYPE, QUANTITY AND LOCATION(S) WITH LANDLORD AND LOCAL FIRE MARSHAL. 12 SUPPLY 4 INSTALL SPRINKLER HEAD ON TOILET ROOM CEILING. COORDINATE EXACT LOCATION WITH CEILING GRID AND LIGHT FIXTURE. MODIFY SUPPLY PIPING AS REQUIRED. 13 PROVIDE AND INSTALL TURNING VANES AT ALL SQUAR CTANSULAR DUCT ELBOWS (TYPICAL). 14 PROVIDE AND INSTALL VOLUME DAMPER AT BRANCH DUCT CONNECTION TO DIFFUSER (TYPICAL). 15 ENSURE TOILET ROOM DOOR 15 UNDERCUT 3/4" (MINA TO FACILITATE AIR FLOW. COORDINATE WITH GENERAL CONTRACTOR 4 H.V.A.C. PLAN KEYED NOTES 3 P.O.C. 1 1 1 3 1 1 H.V.A.C. PLAN SCALE: 1/4" = 1' -0" REVIEWED PUAN CODE CE E C APPROVED MAR - 3 2008 ty Of Tukwila B I - D ❑ echaAlaal atElectriced iurrtt re Gas Pir*Ig City of Tukwila BL• ILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submiltal and may include additional plan review fees. 12/8 EXISTING DUCTWORK W/ LABEL -c:: -FD MAD - e=2 - VD `.J 0 SD 300 GFM 14/6 D -S 24/14 6 -I 0 LEGEND DUCTWORK W/ LABEL FIRE DAMPER WITH ACCESS DOOR VOLUME DAMPER THERMOSTAT W/ PLASTIC LOCKING COVER. MOUNT @ 60" A.F.F. REMOTE SENSOR SMOKE DETECTOR SUPPLY DIFFUSER LABEL RETURN GRILLE LABEL NEW TO EXISTING SPRINKLER HEAD FIRE EXTINGUISHER H.V.A.C. LEGEND Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an : , • r is a nowledged: By Date: City of Tukwila BUILDING DIVISION 0 • • m h p 1 ' V : P r — lidanirmallel 1111111111111111111111111= Awlik • az ■ . rn- _ p - M 1 0 0 210 GFM I4 "x8 "/D -2 210 G I4 "x8 "/D -2 0 F 1 3 1 0 22/ 0 2 6 -I 245 CFM 31 kl _= 11 V 1r2 1 245 :GFM 8 "RD. D -I 1 11 11 RF 0 0 j.. 245 CFM 6 "RD D -I C A Mp o 2 REVISIONS. PROJECT NO. DATE: DRAWN BY: SCALE: FILE: 07 GROSS AREA SALES STOCK TOILET SHEET TITLE J 9 O 0 0 CC c Wzq CC500. LL5h O1M1111 I /23/OS JHW AS NOTED MI I I I -M -I .I .DWG H.V.A.C. PLAN M1.1 1,475 S.F. 1,221 S.F. IQ2 5.F. 65 5.F. i1-1 101.._ HEATING - VENTILATING -AIR CONDITIONING SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION D -I STEAM (LOW pFamsoo STEAM nwEDIUM STEAM (HHIISH PRA Fa AUTOMATIC coma. vALVE TITUS ' * SUPPLY DUCT (5A) SUPPLY %I II 5' p RE6ULATINS VALVE (PRV) 300 -RL 14"x6" b -I RETURN OR FRESH AIR DUCT (RA OR EA) AG TILE TITUS 50 F 22 22 3 26 8 —Q• SAFETY RELIEF VALVE I— CONDENSATE (MEDIUM CONDENSATE MOH PRESSURE) --I II II 41 BL.OIS OFF VALVE SouND TRAP • L HOT WATER SUPPLY (HEATHS) F AND T TRAP ZAP. * /HW — I.w — • 1E:4 GPM I SUPPLY RESISTER OR GRILLE (R OR HOT WATER RETURN (HEATING,/ THERMOSTATIC TRAP SLZE — WA— ETHYLENE 6LYGOL SUPPLY SP. STATIC PRESSURE 1 G RETURN SIZE Wd RESISTER OR 6WLJ >w (R OR 6) —69— ETHYLENE SLYGDL RETURN CIRCUIT SETTER FLOW CONTROL VALVE c FRESH AIR INTAKE (FA) GRILLED WATER SUPPLY AIR BLEEDER VALVE (RADIANT PANEL) I —CM— (� —G CHILLED HATER RETURN —@— AIR ELIMINATOR ROtRG� CEILING DIFI 2 (SUPPLY) S 5 5c+�� � AUTO BAL,4NGING VALVE ~ m , S ROUND ILING DIFFUSER (SUPPLY CE AND RE 11JRIV) F i 7IDIFIGATION LINE � SOLENOID VALVE (REFRIGEfiANT) H S . FOIE. OIL SUPPLY THERMOSTATIC EXPANSION VALVE (REM) SQUARE CBLINS DIFFUSER (SUPPLY) -1'05- FUEL OIL RETURN �I BACK PRE VALVE -- -i oR— 5 JAE GELIN6 DID (SUPPLY D RETURN) AN SIGHT GLASS FUEL. OIL PENT — RN — 0 GAS LINT= — —3— FIFE OR ROUND DUCT RISER SQUARE YV�'Y CEILING DIFFUSER THE TMZOW — d ( ( a REI'RISERANT LIQUID LINE FC.a I COIL UNIT AND MARK ) FL SQUARE CEILING DIFFUSER TWO WAY THRO REFRIGERANT SUCTION LINE CI UH-1 UNIT HEATER-PROPS TYPE 4 MARK RB=RISERANr HOT SAS DISCHARSE LINE ��R■�' AUTOMATIC DAMPER IR:. WADER 44. GANNET UNIT HEATER 4 MARK G— J•vwvn_ GRAVITY DAMPER CONDENSER WATER RETURN GR FT tVH FIN TUBE, MARK AND CAPACITY BOILER BLOW OFF FR D FIRE PAMPER —1330— G-I CONVECTOR AND MARK EXHAUST STEAM E3— ® UNIT VENTILATOR AND MARK —moll— CONCENTRIC MAZER • BASEBOARD' DIFFU59Z FIRST FIGURE IS SIDE SHOUT! ECCENTRIC REDUGI=R ( 2 HEATING, RISER NUMBER H■HOT RN RERE 'WW2 DUGTI G•COLD RETU UNION % Vi 4 O — STRAINER CANVAS CONNECTION EXHAUST FAN RISER NUMEER I., O ZZTPtir EXPANSION JOINT VOLUME DAMPER (ELEV AND PLAN) BR BAS BOARD RADIATION �—� 12(----- THERMOSTAT TURNING VANES o REMOTE SENSOR R THERMOMETER EXTRACTOR Q FRE EURE SASE D I FFUSERS, GRILLES AND REGISTERS MARK SERVICE LOCATION CLG,. TYPE MANUFAC. CATALOG NUMBER REMARKS D -I SUPPLY CEILING. AG TILE TITUS TDGA 6 18x18 24x24 3 26 4 A6 -15 * D -2 SUPPLY DUCT MTD. - -- TITUS 300 -RL 14"x6" b -I RETURN CEILING' AG TILE TITUS 50 F 22 22 3 26 8 * NEIN VAV BOX SCHEDULE (VAV -I) MFR. MOD> =L NO. BASE UNIT WT. UNIT SIZE INLET SIZE OUTLET SIZE TOTAL GFM MINIMUM AIR GFM ( QU VGGFI2 12 I2" Ii "x14" 1,400 245 TRANSFORMATION c10° ELBON 45° ELBOW SIMILAR SUPPLY OR RETURN WYE (REGTAN6UL,4R DUCT) /4 D RETURN AIR BRANCH SITTING DUCTWORK DETAILS SCALE: NONE DUCT HANGER DETAIL EXPANSION THREE TURNING VANES NO THROAT RADIUS ROOF JOIST HANGER WIRE SHEET MIL. DUCT HANGER RECTANGULAR DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS SCALE: NONE c;f0° FIVE SECTION ELBOW 10° BRANCH TAKE —OFF 45° THREE SECTION EL ON ROUND DUCTWORK DETAILS 45° BRANCH TAKE —OFF SCALE: NONE SCALE: NONE SCALE: NONE CONTRACTION SHORT RADIUS c40° EL13O1^I TAKE —OFF USE ONLY I N AREAS INHERE SPACE 15 LIMITED VOLUME DAMPER LOCATED IN ACCESSIBLE LOCATION. PROVIDE ACCESS DOOR OR GABLE OPERATOR IF NOT ACCESSIBLE. FULL RADIUS FULL RADIUS ELBOVAI TAKE —OFF 8 ROUND DUCT HANGER DETAIL u FIBERGLASS INSULATION PER SPECIFICATIONS OPPOSED BLADE DAMPER AT DIFFUSER INSULATE DIFFUSER BACK AND SEAL WITH VAPOR BARRIER TAPE MAX. OF I2" TO 1,__I BRANGH CONNECTION UNLESS NOTED OTHERWISE ROOF JOIST HANGER WIRE ALVINI SHEET METAL DUCT �r MID OM% � TYP. DIFFUSER CONNECTION SHEET MTL. DUCT HANGER SPIRAL. DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU HANGERS RIGID GALVINIZED aO DF- ELBOW METAL STRAP CLAMP (TYPICAL) 2 PLACES INSULATED FLEXIBLE DUCT (MIN. 2', MAX. 5', NO MORE THAN ONE 90° BEND) TRANSITION FITTING �AS REQUIRED SUPPLY AIR DIFFUSER NOTE: VERIFY WITH LANDLORD FOR TYPE OF ELECTRONIC CONTROLS REQUIRED. 6 5 4 VAV BOX DETAIL SCALE: NONE LANDLORDS SUPPLY AIR DUCT MAIN H.P. FLEX DUCT MAX. I'-O' DEA NIG OPERATOR ROOM THERMOSTAT • FOLLOW MANUFACTURERS WIRING DIAGRAM * THERMOSTAT WIRING 1 BY HVAG CONTRACTOR FAN TOILET EXHAUST DETAIL SCALE: NONE SCALE: NONE DIFF. COLLAR SOO -RL S.A. DIFFUSER IISV WIRING 4 J-BOX BY ELECTRICAL CONTRACTOR J-BOX EXHAUST GRILLE CONNECT TO LANDLORD'S TOILET EXHAUST DUCT STUB -IN OR NEV V DUCT THROUGH ROOF. REFER TO KEYED NOTES. \--CEILING MEDIUM TO HIGH PRESSURE DUCT I" INSULATED BOX BACKDRAFT DAMPER (TYP. OF 4) VAV BOX J 3 REVIEWED FOR CODE COMPLIANCE APPROVED City Of Tukwila BUI DING DIVISION MAR - 3 2008 2 ROUND SUPPLY AIR DUCT i DUCT MOUNTED DIFFUSER DETAIL 14O9 cl -��- -- -7) ;9A FEB 1 } 9 2008 �CI fi4;i u I t. rA PROJECT NO. 0r1•1111 DATE: 1/23/08 DRAWN BY JHIN SCALE: AS NOTED FILE: O1MI I I I - M2.1 .DING GROSS AREA SALES STOCK TOILET REVISIONS: 1,415 5.F. 1,221 S.F. IQ2 5.F. 65 S.F. SHEET TITLE: H.V.A.C. SCHEDULES AND DETAILS 0 u7 w T w 0 0.. 00 r CS cc wo Z �w 0 Ow CO I co D 0 CO co CO M2.1 Section 15800 - Heating, Ventilating 6 Air Conditioning (See HVAC drawings) 1.01 GENERAL A SCOPE I. The General Requirements of DIVISION I govern the work in this section. 2. Provide all labor, materials and equipment necessary to properly install automatic, gas - fired heating systems In each unit, supplying air to all rooms where shown on Drawings and called for in the Specifications. S. Equipment as specified together with all necessary ducts, grilles, registers, controls, piping, low voltage fans, control wiring, hangers, stands, equipment supports, flashing at equipment, duct and pipe Insulation, unless otherwise noted. 4. Related Work by Others: a. Painting except as herein specified. b. Line voltage wiring and conduit. c. Electrical supply connection to equipment. B. All work shall conform to all federal, state and local codes and any landlord requirements as specified in the executed Lease Agreement. Mechanical Contractor shall verify and coordinate scope of work with landlord, if specified in the executed Lease Agreement. G. The Contractor shall examine the premises and verify the existing conditions under which he will be obligated to operate In performing this part of the work or that will In any manner affect the work under contract. The Contractor shall cooperate with the other trades so that the installation of all equipment may be properly coordinated. Contractor shall bring to the attention of the Architect/Engineer any discrepancies between field conditions and design documents. D. All equipment furnished shall It the space available, with connection, etc. , in the required locations and with adequate space for operating and servicing. The drawings are generally diagrammatic and Indicate the manner and method of the Installation while the specifications and equipment list denote the type and quality of material and workmanship to be used. Where a conflict exists between the drawings and the specifications, the Contractor shall promptly notify the Architect whose decision shall be final. No allowance will be made subsequently in this connection to behalf of the Contractor after award of the contract. E. Regulations and Codes All mechanical equipment shall conform with the requirements a the State Mechanical Code, the State Building Code, the State Energy Code, NFPA 9oA x6,101 and all applicable local codes and ordinances. F. Drawings for HVAC work are diagrammatic, showing the general location, type, layout and equipment required. The drawings shall not be scaled for exact measurements. Refer to manufacturer's standard Installation drawings for equipment connections and installation requirements as required. Furnish and install ductwork, connections, accessories, offsets and materials necessary to facilitate the system's functioning as Indicated by the design and the equipment Indicated. The work shall be in accordance with local Codes and ordinances and subject to inspection. Contractor shall obtain all necessary permits and pay any associated fees. 6. The Contractor shall install all piping, ductwork and equipment as required to conform the structure, avoid obstructions, preserve Ceiling heights and headroom and make all equipment requiring maintenance or repair accessible. H. The HVAC contractor shall install HVAC systems as shown, noted and specified. Equipment may not be substituted unless written approval by the Architect, Engineer, or Owner's Representative is obtained. Any changes to the ductwork layout will necessitate submission of sheet metal shop drawings for Engineer's review_ Any unauthorized changes will be removed at contractor's expense If deemed necessary by Architect, Engineer, or Owner's Representative. 2.01 MATERIALS A. All ductwork shall be constructed of galvanized steel sheet metal and be fabricated according to the S.M.A.C.N.A. low velocity duct manual, for 2" pressure class. B. All elbows shall have proper radius or HVAC contractor shall provide double thickness airfoil turning vanes required by S.M.A.C.N.A. No square throat elbows shall be installed without double thickness turning vanes. C. All duct connections to equipment shall be loaded type vinyl, vibration elimination Connections, (FC) flexible connections. D. Flex duct: Provide factory assembled Class I air duct (UL 181) with fiberglass insulation and reinforced outer protective cover /vapor barrier. Flex duct shall meet NFPA 41OA with flame spread under 25, smoke developed under 50, and shall be rated for 2" W.G. pressure and 0 to 250 degree temperature. Maximum length shall be 2'-O ". E. All new supply and return ductwork shall be insulated with 2" duct liner, mineral or glass fiber blanket. Duct liner shall meet NFPA 41OA, flame spread under 25, smoke developed under 50. Thickness, density and "R' value shall be per code. Duct liner shall be fastened to inside of ductwork as per manufacturer's directions and S.M.A.C.N.A. "Duct Liner Application Standard ". Size of ducts shall be increased for duct liner insulation, sizes shown on plan are inside free area. Duct wrap shall be foil reinforced kraft facing meeting NFPA 41OA, flame spread under 25, smoke developed under 50, thickness, density and "R" value shall be per code. Duct wrap shall be fastened to ductwork per manufacturer's directions. The round branch ductwork insulation shall be fastened to ductwork per manufacturer's directions. The round branch ductwork shall be Insulated with 1 -1/2" thick fiberglass sleeve with foil jacket and all joints and terminations sealed with foil or duct tape. All supply and return ductwork exposed to view and located in the conditioned space shall be lined F. If ductwrap is the chosen method of insulation, the inside of the supply and return ducts from the air conditioner shall be lined from the air handling equipment to a distance of 10' from the unit, with Ultralite #500 - 1/2" thick, or other approved Duct liner acoustical board. The material shall be fitted carefully on the inside of the duct and shall be fastened on with cement supplemented by screws and washers on top and sides of duct. 2.05 VAV $OX A. SINGLE DUCT VARIABLE AIR VOLUME TERMINAL UNITS; I. UNIT SHALL BE UL LISTED AS A ROM AIR TERMINAL UNIT. TERMINAL UNITS SHALL BE CERTIFIED BY ARI AND BEAR THE ARI 880 SEAL. 2. CASING TERMINAL UNITS SHALL BE CONSTRUCTED OF NOT LESS THAN 22 GAUGE GALVANIZED STEEL WITH A MINIMUM G 60 ZINC COATING. 5. INSULATION THE INTERIOR SURFACE OF THE UNIT CASING SHALL BE INTERNALLY, ACOUSTICALLY AND THERMALLY LINED WITH 1/2" INSULATION WITH A HIGH DENSITY FACING, OF 4.0 POUNDS PER. CUBIC FOOT, RATED FOR A MAXIMUM VELOCITY OF 3600 FPM. THE INSULATION SHALL BE UL LISTED AND MEET NFPA -9OA AND UL 181 STANDARDS. THERE SHALL BE NO EXPOSED INSULATION EDGES (COMPLETE METAL ENCAPSULATION). 4. PRIMARY AIR VALVE THE PRIMARY AIR VALVE SHALL BE A MINIMUM OF 22 GAUGE. THE DAMPER SHAFT SHALL BE SUPPORTED BY SELF - LUBRICATING BEARINGS AND INCLUDE A DAMPER POSITION INDICATOR THE VALUE ASCCMBLY SHALL INCLUDE INTERNAL MECHANICAL STOPS FOR BOTH FULL OPEN AND CLOSED POSITIONS. THE AIR VALVE LEAKAGE SHALL NOT EXCEED 1% OF MAXIMUM INLET RATED AIRFLOW AT 5" N.G. INLET PRESSURE. 5. PRIMARY AIRFLOW SENSOR A MULTIPLE POINT, AVERAGING DIFFERENTIAL PRESSURE AIRFLOW SHALL BE PROVIDED. BALANCING TAPS AND AIRFLOW CALIBRATION CHARTS SHALL BE PROVIDED FOR FIELD AIRFLOW MEASUREMENT. 6. OUTLET CONNECTION TERMINAL UNIT SHALL COME WITH SLIP AND DRIVE CONNECTION. - I. ANALOG ELECTRONIC CONTROLS ANALOG ACTUATOR - A 3 -WIRE, 24 VAC CONTROL ACTUATOR TRAVEL 15 TERMINATED BY END STOPS AT FULLY OPENED AND CLOSED POSITIONS. ANALOG ELECTRONIC CONTROLLER- THE CONTROLLER CONSISTS OF A CIRCUIT BOARD THAT OFFERS BASIC VAV UNIT OPERATION AND ADDITIONAL OVERRIDE FUNCTIONS AND OPERATES USING 24 VAC POWER. THE CONTROLLER USES A PRESSURE TRANSDUCER TO MAINTAIN CONSISTENT AIR DELIVERY REGARDLESS OF SYSTEM PRESSURE GHAN6ES. ANALOG ELECTRONIC THERMOSTAT- THIS SINGLE- TEMPERATURE, WALL - MOUNTED ELECTRONIC DEVICE UTILIZES A THERMISTOR TO VARY THE VOLTAGE OUTPUT IN RESPONSE TO CHANGES IN THE ZONE TEMPERATURE. CONNECTIONS TO THE VAV UNIT CIRCUIT BOARD ARE MADE USING, STANDARD THREE - CONDUCTOR THERMOSTAT WIRE. 5.01 EXECUTION A. All ductwork transitions shall be (FOT) "Flat on Top" unless otherwise specified on plan. All duct dimensions listed are inner air stream dimensions. B. All ductwork shall be routed above the suspended ceiling space unless otherwise noted on the plans. All ductwork shall be supported and attached per S.M.A.G.N.A. standards. C. All outside air Intakes shall be a minimum of 10'- 0" away from exhaust discharge openings and plumbing vent stacks. D. The mechanical systems shall be complete with all necessary appurtenances for a complete operating system. E. Automatic temperature control systems shall be designed and Installed by an experienced contractor: See Automatic Temperature Control Specifications. F. Provide UL approved fire dampers for all penetrations through fire rated walls, partitions, Ceilings, and floors. Install fire dampers as per manufacturer's directions and as per UL guidelines. b. An independent balancing contractor shall balance system to air quantities shown on plan. Balancing contractor shall use duct mounted manual dampers for air system balancing. Use of terminal damper is not acceptable. Balance HVAC systems as per 'Test and Balance Mechanical System Specifications ". H. Owner's Representative shall be notified 48 hours or more prior to all final testing and balancing work so that he may be present to observe this work. The balancing contractor shall submit written reports of all air flow readings, static pressures, GPM rates, pressure readings, temperature readings, motor amperages etc. to document properly balanced air flow in all HVAC systems. I. Provide a volume damper for every inlet and outlet (diffuser, register, grille, etc.) of the supply ductwork distribution system whether shown or not on the plans. Provide additional volume dampers and/or extractors at branch take -offs from ductwork mains as required to achieve ARI volume distribution and balancing. J. The contractor shall warranty all materials and guarantee all workmanship for one year from substantial completion. Provide full 5 year guarantee on all air conditioning compressors. K. Submit two Operation and Maintenance Manuals bound in 8 -1/2" x II" page binders, titled "Operation And Maintenance Manual ". Subdivide binder contents with page dividers by system and equipment. Include all shop drawings, test and balance reports and warranties. Submission of these documents shall be a requirement for final payment. L. Ductwork shall be tested to 2 inches WAS. and meet Seal Class C allowable leakage. Ductwork shall be tested In sections as the installation proceeds. Any leaks shall be sealed before the next section is installed. Tested sections shall be marked with indelible marker, showing date and initials of contractor foreman responsible for the test. M. Low and medium pressure supply and return ductwork shall be sealed in accordance with S.M.A.C.N.A. Seal Class C. N. Core -drill or saw -cut existing walls, roof, etc. as required for piping or ductwork and fire -stop opening around pipe or ductwork. Verify location of structural beams, joists, etc. before drilling or cutting. Notify architect of any discrepancies. 0. Wherever foundation walls, outside walls, roofs, etc. are cut for installation of systems, they shall be patched to match existing construction and sealed weather tight. Work shall be performed by craftsmen skilled In their respective trades. P. Provide 3 sets of pleated disposable filters. One set to be used until completion of construction phase. Install one set at completion of construction phase and deliver one set to owner and label each set of filters to denote their respective HVAC units. Filters shall be similar to Farr D /C -22. Section 15'400 - Test and Balance Mechanical System Specifications 1.01 GENERAL A. The mechanical equipment shall be completely installed and in continuous operation as required to accomplish the adjusting and balancing work specified. B. Perform adjusting and balancing when the system is operating at design capacity. C. Only qualified personnel shall perform balancing work. I. Submit evidence that the personnel who will perform the balancing of the project systems are certified for review by the Owner/Engineer prior to performing the work. 2. Qua lified contractors shall be holders of a certificate from a nationally recognized testing and balancing standards committee/ organization, AABC or NEBB only. D. The balancing contractor shall be completely independent of the installing contractor. Any form of association is unacceptable. Documented proof of independence by the balancing contractor is required and shall be submitted to Owner prior to start of balancing work. E. During substantial completion inspection, a percentage (not more than 5 of the recorded data) will be subject to reverification by the Owner/Englneer. Contractor shall take instrument reading as required. 1.02 Submittals: A. Submit data sheet on each item of balancing equipment as required for O ner/Engineer review. I. Include name of device 2. Manufacturer's name 3. Model number 4. Latest date of calibration 5. Correction factors B. Submit a report containing all data and other related information recorded during balancing, placed on appropriate forms for Owner/Engineer review. Reports shall certify that the methods used and results achieved are as specified. C. Submit copies of report to Owner and to Engineer. Provide (5) copies of report to Engineer for review. Provide (2) copies of report to Owner. 1.05 Air system (adjust and balance system in accordance with the following requirements): A. Preliminary: I. Identify and list: a. size, b. type and manufacturer of all equipment to be tested c. Including air terminals d. check all system components for proper installation and operation. 2. Verify all fans and motors for proper rotation. 5. Use manufacturer's ratings for all equipment to make required calculations, except where field test shows rating to be impractical. 4. Verify that all instruments are accurately calibrated and maintained. 5. Install clean filters. 6. Simulate wet cooling, coil with baffles. B. Central System: I. Adjust and record supply, return and exhaust fans rpm to design requirements within the limits of mechanical equipment provided. 2. Test and record motor voltage and running amperes including motor nameplate data and starter heater ratings. 3. Make pitot tube traverse of main supply, exhaust and return ducts, determine and record cfm at fans and adjust fans to design supply cfm with +/- 5% tolerance. 4. Record system static pressure, suction and discharge. 5. Adjust system for design outside air cfm, see schedules. 6. Adjust system for design recirculated air, cfm. 7. Record heating apparatus entering air temperatures, dry bulb in degree F. S. Record cooling apparatus entering air temperatures, dry bulb and wet bulb in degree F. GI. Record heating apparatus leaving air temperatures, dry bulb in degree F. 10. Record cooling apparatus leaving air temperatures, dry bulb and wet bulb In degree F. C. Distribution: I. Adjust zones or branch ducts to design cfm. D. Air terminals (diffusers and grilles): I. Identify each air terminal on reports as to location and determine required flow reading. 2. Adjust each air terminal to design requirements with +/- 10% cfm tolerance. 5. Balance procedure on air terminals shall include: comparison of required fpm velocity and observed velocity, adjustment of terminal, and comparison of required cfm and observed cfm after adjustment. 4. Adjust flow patterns from air terminal units to design intent and as equipment permits. E. Verification: I. Prepare summation of readings of observed cfm for each system. Compare with required cfm. Determine coil and filter static pressure drops. 2. Verify design cfm at Pans as described in 1.03.5.2 above: building shall be under slight positive pressure in normal operating mode. 1.04 Automatic Control System: A. The temperature control contractor's representative shall set and adjust automatically operated devices to achieve the required sequence of operations. B. Balancing contractor shall verify all controls for proper calibration and list those controls requiring adjustment by temperature control system installer. Section 15 - Automatic Temperature Control Specification A. Automatic Temperature control system shall be installed by a contractor with minimum five (a) years of experience In the installation of electric and electronic control systems. B. All wiring and wiring connections shall be provided by the control contractor unless shown on electrical drawings. All wiring shall comply with the electrical specifications and local electrical codes. G. Provide all relays, contactors, switches, adjustable set - points, wiring, conduits and transformers as required for automatic temperature control system. D. At completion of work, adjust and make ready for operation all thermostats. Pampers, switches and other control devices. Provide manuals and instruction to the building operating personnel. Provide one year guarantee after final acceptance of work to cover all materials and labor to be repaired /replaced by the control contractor at no cost to Owner. Provide wiring diagrams of all systems and turn over to Owner. SPRINKLER SYSTEM Shop drawings - the sprinkler contractor shall submit shop drawings to the tenant's landlord and to the appropriate authorities and Insurance underwriter for their approval. A copy of the approval letter from these authorities shall be forwarded to the tenant, landlord and design architect. SPRINKLER. HEAD TYPES SHALL BE AS FOLLOWS: I. Sprinkler heads In sales /public area must be fully concealed and covered with plates finished /painted to match adjacent surface. Center sprinkler heads in ceiling tiles where applicable. 2. Acoustic tile ceilings (non public areas) semi- recessed All piping shall be threaded black steel meeting astm al35. All pipe fittings are required to be pressure class 115, but not less than the system rating. INSPECTOR'S TEST CONNECTION Tenants who require 50 sprinkler heads or more within their Demised Premises are required to complete a 3rd party review prior to the Fire Department Sprinkler permit submittal. Tenants shall utilize the following Washington State Review Board engineer for this review: Tuazon Engineering, PLLC Eric P. Tuazon, PE 4322 NE 1th Street Renton, WA 4180541 Telephone: (425) 4111 -1683 Facsimile: (425) Ql1 -1105 E -mail: eric @tuazon.com COMMISSIONING REFER TO NREG SECTION 1416 AND THE BUILDING COMMISSIONING GUIDELINES, PUBLISHED BY THE BUILDING COMMISSIONING ASSOCIATION, FOR COMPLETE TEXT AND GUILDELINES FOR BUILDIN6 COMPLETION AND COMMISSIONING REQUIREMENTS. TESTING AND ADJUSTING CONTRACTOR SHALL DEMONSTRATE OPERATION OF SYSTEM TO FULL SATISFACTION OF TENANT, SHALL BALANCE AIR FLOW IN ACCORDANCE WITH AIR QUANTITIES ON DRAWIN65 AND SHALL RECORD VOLUME READIN65 IN ACCORDANCE WITH ASHRAE AND PROVIDE SAME TO TENANT. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: A. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. B. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. C. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PRO6RAMMING COMMENTS. D. COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING PER GOVERNING PLUMBING CODE. REVIEWED FOR CODE COMPLIANCE APPROVED MAR - 3 2008 City Of Tukwila UI. ING DIVISION Mo8 0'x(0 FEB 19 2008 �'ki bd's3 CLs tF� PROJECT NO. 01MIIII DATE: 1/23/OS DRAWN BY: JHW SCALE: AS NOTED FILE: O1MI I I I -M -3. I .DWG GROSS AREA SALES STOCK TOILET REVISIONS: SHEET TITLE: FLV.A.C■ SPECIFICATIONS M3.1 1,418 S.F. 1,221 5.F. Iq2 S.E. 63 5.F.