Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-047 - WESTFIELD SOUTHCENTER MALL - GYMBOREE
GYMBOREE 1066 SOUTHCENTER MALL M08 -047 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Cityef Tukwila 6364200010 1066 SOUTHCENTER MALL TUKW GYMBOREE 1066 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA SARAH NIELSEN 1120 E 80 ST, STE 211 , BLOOMINGTON MN PRODIGY CONSTRUCTION MANAG LTD 186 N HIGH ST , COLUMBUS OH Contractor License No: PRODICM966CS DESCRIPTION OF WORK: MECHANICAL FOR TENANT IMPROVEMENT: (1) NEW VAV, NEW DUCT WORK, NEW CONTROLS, AND (1) NEW EXHAUST FAN. Value of Mechanical: $40,000.00 Type of Fire Protection: SPRINKLERS /AFA Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 1 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY * *continued on next page ** M08 -047 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 800 541 -0821 Phone: 614 - 337 -0908 Expiration Date: 04/10/2010 M08 -047 05/14/2008 11/10/2008 Fees Collected: $680.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 4 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 Printed: 05-14 -2008 Permit Center Authorized Signature: I hereby certify that I have re. - d examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will • c plied with, whether s�p - ified herein or not. The granting of this • 't does n e to j.*' authority to violate or cancel the provisions of any other state or local la regulating construction or rmance - d to sign and obtain this mechanical permit. Date: `� C / DS Signature: Print Name: doc: IMC-10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -047 Issue Date: 05/14/2008 Permit Expires On: 11/10/2008 Date: 4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -047 Printed: 05-14 -2008 1: ** *BUILDING DEPARTMENT CONDmONS * ** • City of Tukwila Parcel No.: 6364200010 Address: 1066 SOUTECENTER MALL TUB:W Suite No: Tenant: GYMBOREE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 047 Status: ISSUED Applied Date: 02/19/2008 Issue Date: 05/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -047 Printed: 05 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond - 10/06 * *continued on next page ** M08 -047 Printed: 05-14 -2008 doc: Cond -10/06 r i City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permi = • es not presume to ve authority to violate or cancel the provision of any other work or local laws regulating construction or the pe • - ance of work. d. Signature: AP / 0 do Print Name: , / 4 7/dg Date: M08 -047 Printed: 05 -14 -2008 • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. t+'a. us Mechanical Permit No. �Il1,1171 i Plumbing /Gas Permit No. PM - OG1 Public Works Permit No. Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: do 3Co '26 - tit Site Address: (tOkp Sn`► nc^• ont ViciAk Suite Number: IZJ- O Floor: Tenant Name:M1D6[ New Tenant: ❑ Yes II ..No Property Owners Name: V e-\G\ Coc , c . a.k ■c r `rV . . Mailing Address: 1kr�9 W>, \Stnire Pc \e -'Ja'r d , LOS Anal e_<eS, CA ccO ZS CitY State Zip CONTACT PERSON: who do : wecontact when your permit is ready to be issued Name: - .1 via VN Ni P$Seln Day Telephone: I41 OR'zA Mailing Address: %I20 i=n c$ StetV1 SA e* - Su:Ore '2...\\ (" AccBfv1i`C ADn HN S'S- City State Zip Fax Number: OS Z ➢ g S►-I - 4q 09. E -Mail Address: So' A ec , C C)Yv1 GENERAL CONTRACTOR INFORMATION' "" (Contractor Information for Mechanical (pg 4): for Plumbing and Gas Piping (pg 5)) Company Name: 7. S. Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of. Record Company Name: A '\soor. , Mailing Address: %GtCb ('s et Rtxxd -Sete BOO St• MC) G,3\'•$Co City State Zip Day Telephone: 'A t 41 t4 i S • 24-bp Fax Number: 1 L$ I - 7.1Z.On Contact Person: C -4129 W:1nC.NNe S - ems E -Mail Address:9 ) \ CYIe.S C . COwY1 ENGINEER OF RECORD _ All plans must be wet stamped by Engineer of Record Company Name: /aclr \ASYw\ try State Mailing Address:igS) Cr(' i Rott.• ak Zed S1. Lt .JS MO f07, l City State Contact Person: 6t i.l )i YlC,f1�5 t t't� E -Mail Address: C Vr:sk -e ' C. ri'ct"A0, C.•W1 Q:\Applications\Ponns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh Day Telephone: :"St DLI IS•2-400 Fax Number: A iv-$ ( 4 IS . 2..S00 Zip Zip Page 1 of 6 BUILDING PERMIT INFO Valuation of Project (contractor's bid price): $ 4 045, 000 Existing Building Valuation: $ Scope of Work (please provide detailed information): s e.Q\ot^frkrabY■ of P NS$1yy - $ P.try i 1- %rVtca v1P S‘r Mcal% elc f1corNSiflr\ car °.a.. Will there be new rack storage? ❑ Yes 1s` Floor • 2nd Floor 3.' Floors Basement Provide All Building Areas in Square Footage Below AceessoiyS - Attached Garage : Detached Garage., Attached Carport, • : Detached Carport. Covered "Dee Uncovered Deck Lot Area (sq ft): Z. ZCpO ❑.. No If yes, a separate permit and plan mittal will be required. Interior Rembdel 7-124 FIRE PROTEC ON/HAZARDOUS MATERIALS: 'Addition to Ezistiii ::• Structure .:. . TYjie of Construction per: BC'. • .? . . Type of: • Occupancy per IBC PLANNING DIVISION: Single family building footprint (ar of the foundation of all structures, plus any decks over 18 inches and o rhangs greater than 18 inches) * For an Accessory dwelling, pro , de the following: Floor area of principal dwelling: Floor area •' + ccessory dwelling: *Provide documen . / on that shows that the principal owner lives in one of the dwellings as his or her prima ``': sidence. Number of Parking Stalls .'rovided: Standard: Compact: Hang` , ap: Will there be a change •- use? ❑ Yes I No if `yes ", explain: S t •nklers • Automatic Fire Alarm ,a" None j2" Other (specify) Will there be st• . ge or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 - 1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q:\ApplicationsWonns- Applications On Line13.2006 - Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Unit Type: • Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser AA 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct U Thermostat „ 1 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM y Incinerator — Comm/Ind MECHANICAL PERMIT INFORMATION - 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: T. Mailing Address: Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ 401 E bOO Scope of Work (please provide detailed information): 0 t &% ) , 1/4/ AV rji J ?t i,xtirv.. fY.W r ow\-lerrg \S Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric IP Gas .... Other: Indicate type of mechanical work being installed and the quantity below: QMpplications\Fonns- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City State Zip Page 4 of 6 Water District ❑ ...Tukwila ❑ ...Water Availabr ty Provided Sewer District ❑ ...Tukwila ❑ .. -Sewer Use Certificat ❑ ...Total Cut ❑ ...Total Fill Water Meter Refund/Billinn: Name: Mailing Address: PUBLIC, WORKS PERMIT INFORMATION - 206 -433 -0179 Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ❑...Water District #125 Proposed Activities (mark boxes that apply): ❑ .:.Right -of -way Use - Nonprofit for less than 72 h ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right -of -way Non Right -of -way ❑...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water Q: Applications\Fotms- Application On Line1.1-2006 - Permit Application.doc Revised: 9-2006 bb 0..- Va1Vue ❑ .. Renton ❑ ... Sewer Availability Provided Septic System: ❑ On -site Septic System — Fo 'n -site septic system, provide 2 copies of a current septic des ❑ .. Aband• ' Septic Ta ❑.. Curb )' ❑ .. Pay ent Cut ❑ .. ped Fire Line Submitted with A > • lication mark oxes which apply): ❑ ...Civil Plans (Maximum Paper Si — 22" x 34") ❑ ...Technical Information Report (Sto ',arainage) ❑ .. Geotechni Report ❑...Traffic Impact Analysis ❑ . -.Bond ❑ .. Insurance ❑ .. Easement(s) ❑ -- Mainte ce Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) cubic yards cubic yards ❑ .. Highline ❑ .. Renton ❑ ght -of -way Use - Profit for less than 72 hours ❑ �' ight -of -way Use — Potential Disturbance .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Permanent Water Meter Size... WO # ❑...Temporary Water Meter Size.. , " WO # ❑ ...Water Only Meter Size WO # ❑ ...Dedu Water Meter Size ❑ ...Sewer Main Extension ' ; +:lic Private ❑ ...Water Main Extension blic Private FINANCE INFORMATION Fire Line Size at Property Li ;`' Number of Public Fire Hydrant(s) ❑ .- .Water I; ...Sewer ❑ ...Sewage Treatment Monthly Service Billin o: Name: Day Telephone: Mailing Address: City Day Telephone: City Battle approved by King County Health Department- ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding >I State Zip State Zip Page 3 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI1D AGENT: Signature: ( X Date: 21 Vai o$ Print Name: SOA 14■ e.` Sew Day Telephone: $OO 1S4 - O�R2.fl Mailing Address: t t 20 60.Sk $0 Y1 S\ct - Z \\ s\c c rc IA t3 SS4 -2-0 City State Date Application Expires: v7:fig In) Date Application Accepted: VII lei 'at Q:'Applications\Fonns- Applications On L,ne'3 -2006 - Penn Applicanon.doc Revised: 9 -2006 bh Staff Initials: d Zip Page 6 of 6 Fixture Type: Qty Fixture Type: 9 Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain •, ater cooler (per head) i Wash fountain Gas piping outlets Bidet • Food -waste t q , commercial �' Receptor, indirect aste Clothes - washer, domestic Floor drain t Si ` . s Dental unit, cuspidor Shower, si e head trap Urin `, Dishwasher, domestic, with independent drain Lavatory Water fill set lk Building sewer or trailer park sewer Rain ' er system — per drain nside building) Water heater s,,d/or vent i Additional medical gas inlets /outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Rep or alteration of water pi i g and/or water treating e ipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets /outlets for specific gas PLUMBING AND GAS PIPING PERMIT INFORMATION 7 ,200-431-3070 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: T, t3 • D • Mailing Address: City Contact Person: Day Telephone: E -Mail Add s: Fax Number: Contractor Reg ; tration Number: Expiration ! • e: Valuation of Plumbing ork (contractor's bid price): $ (D, OM Valuation of Gas Piping `r. k (contractor's bid price): $ Scope of Work (please provi detailed information): N2e,J L„733re... tAXA:Prt^da .' Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping ou is being installed and the quantity below: Q:\ Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Sewer: Page 5 of 6 Payee: PRODIGY CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11195 556.00 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -047 Address: 1066 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/19/2008 Applicant: GYMBOREE Issue Date: Receipt No.: R08 -01624 Payment Amount: $556.00 Initials: WER Payment Date: 05/14/2008 11:39 AM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 556.00 Total: $556.00 2405 05/14 9710 TOTAL 556.00 doc: Receipt -06 Printed: 05-14 -2008 RECEIPT NO: R08 -00471 Initials: JEM Payment Date: 02/19/2008 User ID: 1165 Payee: ELDER -JONES SET ID: S000000965 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us D08 -094 1,036.10 EL08 -164 110.70 M0� 124.00 PG08 -051 29.00 TOTAL: 1,299.80 TRANSACTION LIST: Type Method Description Payment Check 50879 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT TOTAL: Total Payment: 1,299.80 Amount 1,299.80 1,299.80 Account Code Current Pmts 000.345.832.00.0 110.70 000/345.830 1,189.10 TOTAL: 1,299.80 8 7 81 02 /19 9710 TOTAL 1299.80 Prod G /r9 Type of I eccti Address co mini Date Called: pecial Instructions: Da a ant ' m • • j Sr - a c� Requester: P hon e q -35 // PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION NO. INSPECTION RECORD Retain a copy with permit moi3-6 (206)431 -3670 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: c'(c 5M:be SP bit 'Inspector: Date: n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: PType n y,r•N « of Inspection: '\/,. t Address: \(G N\ \\ Date Called: Special Instructions: Date Wanted: d:: t • ( \� a.m. p.m. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. COMMENTS: PERMIT NO. (206)431 -3670 Re A of A \‘‘\feS•.* \1(\ ‘-'Nn ( ?\ .4 Corrections required prior to approval. Inspector: Date: ~ t Z- oZ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: IDate: /c, COMMENTS: o Type of Inspection: ` - � CY+L. C `�L. &I. .& a ./ ►rte (`^, ^Ar -,10.. r ..k.cc \fit:t . C .4,, Special Instructions: Date Wanted: - 1 • \ r r..w Le \ y a - 1 i , .. vin . - Z,...... Phone No: • Project: . C r' %! ,M0 < e._ 4r Type of Inspection: ` - � CY+L. C `�L. &I. .& Address: I k Q (.., C. N\c.. \\ Date Called: Special Instructions: Date Wanted: - 1 • \ • U eic a.m. p.m. Requester: Phone No: Approved per applicable codes. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -'6 0 Corrections required prior to approval. Inspector: (Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: COMMENTS: .:;.- VAtt) - / Q'.Iw- device 4 /7p - f'Ased .. e., /, 4. ..)A- L AB C_ - ∎ F • Special Instructions: Date Wanted: 6,/ / Aid Requester: Phone No: Z6 C — LSO 'S ' \ Project: /� c y m 0 ✓ e e Type of Inspection: S KK S A- Olvwp, Address: /0 `_ 6 JAGL Date Called: Special Instructions: Date Wanted: 6,/ / Aid Requester: Phone No: Z6 C — LSO 'S ' \ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Approved per applicable codes. Corrections required prior to approval. 1 lns pecte• Date: 694 /b ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: $ 4? * 00`, *— m Project: Type of Inspection 2 0,4 214 Address: /0(06 Ala., Date Called: Special Instructions: Date Wanted: / P Requester: Phone No_ 2 (O 345'7 r for -oV7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ft 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: ( F ECTION FEE REQUIRED. Prior to inspection. fee must be paid at ® $58.00 uthcenter Blvd., Suite 100. Call the schedule reinspection. 'Receipt No.: Date: h Project Info Project Address GYMBOREE Date 2/27/2008 SOUTHCENTER MALL For Building Department Use SEATTLE, WASHINGTON Applicant Name: Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form Rr6 FREDERICK J. GOGLIA STATE OF WASHINGTON INCOMPLETE Permit No.. piar approval is subject to errors and otritssions. 'r P.1:11cr7.7:7 M08-091 CL Of Tukwila B ILD ND IN REVIEWED FOR CODE COMPLIANCE APPROVED MAR -52018 Revised July 2007 RECEIVED FEB 28 2008 PERMIT CENTER Cooling Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location VAV -1 TITUS ATQS -7 55080 2550 590 N/A N/A IN SPACE Fan Equipment Schedule Equip. ID Brand Name Model No. CFM SP HP /BHP Flow Control Location of Service VAV -1 TITUS ATQS -7 2550 0.50 1 HP VAV IN VAV 9 KW N/A Heating Equipment Schedule Equip. ID Brand Name' Model No. Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency VAV -1 TITUS ATQS -7 17070 2550 590 9 KW N/A Project Info Project Address GYMaOREE Date 2/27/2008 SOUTHCENTER MALL For Building Dept. Use SEATTLE, WASHINGTON Applicant Name: Applicant Address: Applicant Phone: 2006 Washington State Nonresidential Energy Code Compliance Form T ech anica l ummar i i'a i i s 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option Q Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. 1 If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. ° COP, HSPF Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? ❑ <20,000 Btuh? ❑ Economizer included? If Heating Only: 9 Y ❑ 5000 cfm? <5000 ❑ <70 /o outside air? <70% ir 11 i ech „Su u Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only 2006 Washington State Nonresidential Energy Code Compliance Form Reference Section 1421 Heating /Cooling or Cooling Only Simple System Allowed (section 1420) Yes Reference Section 1423 otal Ca . wo economize <240,000 Btuh or 10 %? Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. Open Motors Closed Motors 3,600 1,800 1,200 3,600 1,800 1,200 Efficiency ( %a) Efficiency ( %) - 82.5 80.0 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 92.4 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 ectric:M 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). VAV Motor No. or Location Minimum Nominal Full -Load Efficienc Synchronous Speed (RPM) HP 1.0. 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 1 HP 2006 Washinston State Nonresidential Energ Code Compliance Form GYMBOREE Type (open /closed) open FAN POWERED VAV Description of Application or Use Date For Building Department Use Synch. Speed 1200 2/27/2008 Revised July 2007 Min.Nom. Full load Efficiency 85.0% Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14 -1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. '+,f; -,41 Mec anic .:4 . 1 ., , �l. y r 2006 Washington State ,� „,'Jr.rr xi`� . :�: R;St ` - � 4P , � n'y5'1 "�`' ^ 7, `, i . , Pf Permit P lansCh ec kl i st � t w�tt�� II ,MECH CHK t v �I : T;Y'�, 4 _',, _, . a .i 7.f �.� i .n 1.. 4.Mn .'r . ,C,' ✓11Pa�: -'Z'� , .. , ..2a�'m 1 „i5 ....4i .`4 it�rlrx .4.•.. .;i.a: #,Y r 25 inn:;. + Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address GYMBOREE Date 2/27/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule n.a. 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency n.a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans M1.0 n.a. 1412.2 Deadband control Indicate 5 degree deadband minimum n.a. 1412.3 Humidity control Indicate humidistat n.a. 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage M3.0 n.a. 1412.4.2 Optimum Start Indicate optimum start controls n.a. 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n.a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans m1.0 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas n.a. 1422 Thermostat interlock Indicate thermostat interlock on plans n.a. 1423 Economizers Equipment schedule 1413 Air economizers n.a. 1413.1 Air Econo Operation Indicate 100% capability on schedule n.a. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance n.a. 1413.3 Integrated operation Indicate capability for partial cooling n.a. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary M yes 1414.2 Duct insulation Indicate R -value of insulation on duct Ml .0 n.a. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan M1.0 yes 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing Ml .0 n.a. 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report M1.0 n.a. 1434' Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 - 1454) 1440 Service water htg. n.a. 1441 Elec. water heater Indicate R -10 insulation under tank n.a. 1442 Shut -off controls Indicate automatic shut -off n. a. 1443 Pipe Insulation Indicate R -value of insulation on piping n. a. 1452 Heat Pump COP Indicate minimum COP of 4.0 xi. a. 1452 Heater Efficiency Indicate pool heater efficiency n. a. 1453 Pool heater controls Indicate switch and 65 degree control n. a. 1454 Pool covers Indicate vapor retardant cover n. a. 1454 Pools 90+ degrees Indicate R -12 pool cover 2006 Washington State Nonresidential Energy Code Compliance Form no is circled for any question, proviae explanation: 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form M e a cha n ical ; Perirnit. ec kli Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo lng Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable,of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time fora power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. c. Automatic modulating control of the outdoor air damper, or A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washington State Nonresidential Energy Code Compliance Forms 2006 Washington State Nonresidential Energy Code Compliance Form M e a cha n ical ; Perirnit. ec kli Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14 -1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu /h (65 kW), including electric furnaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo lng Equipment: Packaged electric equipment providing both heating and cooling with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable,of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time fora power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stories in height. 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply Revised July 2007 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. c. Automatic modulating control of the outdoor air damper, or A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb /40 ° F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246- 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 2. are isolated from the exterior with an automatic shut -off damper complying 2006 Washington State Nonresidential Energy Code Compliance Form 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements, any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. Exception: Piping installed within unitary HVAC equipment. Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAG 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines, published by the Building Commissioning Association, for complete text and guidelines for building completion and commissioning requirements.) air capacities exceeding 10,000 cfm shall have optimum start controls, Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy. The control algorithm shall, as a minimum, be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate when supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. March 25, 2008 City of Tukwila 6300 Southcenter Blvd Tukwila, WA 98188 RE: Gymboree Westfield Southcenter Project No. 080078 To Whom It May Concern: • • AR Si t 4 w N I N C O R P O R A T E D S A I N T L O U I S / D A L L A S ARCHITECTURE • ENGINEERING • STORE PLANNING This letter is in response to changes to the approved permitted drawings for the above project. If you have any questions, comments or need any additional information regarding this letter please contact Greg Winchester at ArcVision Inc. 800 - 489 -2233. A0.0 Revised landlord contact info. A0.1 Added rear door signage to door hardware schedule. Revised ceiling spec for stockroom. Updated ceiling information on responsibility schedule. A2.1 Revised floor plan keyed note 4A & 16. Updated partition legend for extent of gypsum board. A3.1 Added ceiling to stockroom and revised sales ceiling to gypsum board. Added landlord notes. A4.1 Revised elevations to indicate gypsum ceiling and ceiling in stockroom. A5.1 Revised spec for reveal. A5.2 Revised spec for reveal. Added note for gypsum board and tenant side of mall bulkhead. A5.3 Revised spec for reveal. Indicated fire retardant plywood on details 2 & 3. A6.1 Added seismic ceiling detail #9 & revised detail 5. Added or revised details 3 & 6 for gypsum board. A6.2 Revised gypsum board height on detail 3 & added note to detail 8. A6.4 Indicated gypsum board ceiling on detail 4. E1.1 Added power general notes 22 -24 & revised height on keyed note #8. E2.0 Revised lighting keyed notes 1, 2 & 3. Added emergency lighting in restroom. E3.0 Revised light Dl.. E4.0 Revised power riser diagram & revised panel schedule HV. E5.0 Revised spec section 16201. 1950 Craig Rd. - Suite 300 • St. Louis, MO 63146 • Phone (314) 415 - 2400 • Fax (314) 415 - 2300 M1.0 Revised ceiling in sales to gypsum board. M2.0 Added landlord notes. M2.1 Added landlord notes. Sincerely, Greg Winchester Project Manager CC: File Arc Vision Inc. 1950 Craig Rd. — Suite 300 • St. Louis, MO 63146 • Phone (314) 415 -2400 • Fax (314) 415 -2300 February 25, 2008 Sarah Nielsen 1120 East 80 Street, Suite 211 Bloomington, MN 55420 RE: Letter of Incomplete Application # 1 Development Permit Application M08 -047 Gymboree — 1066 Southcenter Mall Dear Ms. Nielsen, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 19, 2008 is determined to be incomplete. Before your application can continue the plan review process the following items from the following department needs to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions concerning the following comments. 1. Provide a mechanical summary compliance form that complies with the 2006 energy codes. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted throw': the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: M08 -047 • Cizy of Tukwila P:\Permit Center\Incomplete Letters \20081M08 -047 Incomplete Ltr # 1.DOC jem • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M08 -047 DATE: 04 -01 -08 PROJECT NAME: GYMBOREE SITE ADDRESS: 1066 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 BEFORE Permit Issued DEPARTMENTS•. 4 , 3 BulIitn: v ision Public Works •PERMIT COORD COPY • PLAN REVIEW /ROUTING SUP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n Planning Division Permit Coordinator DUE DATE: 04 -03-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Ft Structural Review Required No further Review Required REVIEWER'S INITIALS: Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 DATE: DATE: APPROVALS Of CORRECTIONS: Approved V Approved with Conditions n Not Approved (attach comments) n DUE DATE: 05-01-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Complete Comments: g Division Public Works REVIEWER'S INITIALS: • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -047 DATE: 02 -28 -08 PROJECT NAME: GYMBOREE SITE ADDRESS: 1066 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) APPROVALS OR CORRECTIONS: Incomplete Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 Fire Prevention a DUE DATE: 03 -04 -08 DATE: DATE: Planning Division Permit Coordinator Not Applicable Not Approved (attach comments) n DUE DATE: 04 -01 -08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DEPARTMENTS: Buil g D vision Public Works Comments: PERMIT COORD COPYA PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -047 DATE: 02 -19 -08 PROJECT NAME: GYMBOREE SITE ADDRESS: 1066 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued � A Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete Planning Division n Permit Coordinator Permit Center Use Only n ' �, INCOMPLETE LETTER MAILED: '7. LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg [✓5 Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 DUE DATE: 02-2 1 -08 Not Applicable n EY No further Review Required DATE: DATE: n n DUE DATE: 03 -20-08 Approved Approved with Conditions I Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: ( (, .l )L/t' i(Lt7 tTv Received by: R eceived by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS S ummary of Revision: Received by: PROJECT NAME: (r(Alubt SITE ADDRESS: 1 CU/ G,i 1,,11VC19 REVISION LOG PERMIT NO: • nn nn 'b /v� ORIGINAL ISSUE DATE: lease print) (please print) (please print) (please print) IT 141A (please print) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us i REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 12g log' Plan Check/Permit Number: rn0o -041 ❑ Response to Incomplete Letter # ❑ Response to Corr cti Letter # Revision # ermit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECeive MN' rtiKwitA APR 01 2008 Project Name: G � 1rprp PERMIT CENTER Project Address: 10 6c, c,- ,1*Ner-ph}e-r ry 1\ Contact Person: F.4-,, cah I4 t? \ sec\ Phone Number: Qb IS-41 - 0 "2-1 Summary of Revision: ArArkerk laxu4 \c c-d 1�� p S tV_V ASP CP ■ YNC3 de! cA..0 ,camu pa Sheet Number(s): M 1. M Z .0 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: O . Entered in Permits Plus on atilb \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • • Steven M. Mullet, Mayor Steve Lancaster, Director Date: fr0/0 g CrentP.n• R_Ia_7n(1a City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. � Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner • • Plan Check/Permit Number: Sheet Number(s): W A- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: f', Entered in Permits Plus on ,)- - d g lapplications\forms- applications on !ine\revision submittal ha 0 04-7 Steven M. Mullet, Mayor Steve Lancaster, Director Project Name: Project Address: 1O G S 0141 C47Z L tr Contact Person: J' 4 1 - E - t off N Phone Number: I "� - Qgz f Summary of Revision: p iLovvvr 20v6, cuP E tOgm A ' FIECttv CITY OF Tt ►KWILA FEB 2 8 711fl8 rtrtivu I ZEi License Information License PRODICM966CS Licensee Name PRODIGY CONSTRUCTION MANAG LTD Licensee Type CONSTRUCTION CONTRACTOR UBI 602362604 Ind. Ins. Account Id VICE PRESIDENT Business Type CORPORATION Address 1 186 N HIGH STREET Address 2 City COLUMBUS County OUT OF STATE State OH Zip 43230 Phone 6143370908 Status ACTIVE Specialty I GENERAL Specialty 2 UNUSED Effective Date 2/10 /2004 Expiration Date 4/10/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HOLBROOK, JOE PRESIDENT 02/10/2004 GUNNOE, BRIAN VICE PRESIDENT 02/10/2004 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond #2 Bond Company Name CINCINNATI INS CO Bond Account Number B8857387 Effective Date 03/11/2004 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 03/29/2004 THE Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PRODICM966CS 05/14/2008 STRUCTURAL ELEVATIONS BASED ON: HELD SURVEY - STRUCTURAL DRAWINGS STORE IS LOCATED ON LEVEL 1 OF 2 FINISHED FLOOR TO BOTTOM OF DECK ABOVE IS APPROX. UNKNOWN FINISHED FLOOR TD BOTTOM OF LOWEST OBSTRUCTION (STEEL OR CONCRETE BEAMS /JOISTS, PIPING, ETC.) IS APPROX. UNINIOWN ALL OTHER EQUIPMENT, PIPING, AND DUCTWORK ELEVATIONS ME AS NOTED ON THE DRAWINGS. NOTE: CONTRACTOR IS TO VERIFY ALL CONDMONS IN THE FELD PRIOR TO BIDDING WORK. AMY CONDITIONS THAT AFFECT THE INSTALLATION OF THE PROJECT MUST IMMEDIATELY DE BROUGHT TO THE ATTEMiON OF THE CONSTRUCTION MANAGER OR BE INCORPORATED N THE BE . DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANT'S CONS1RUCilON MANAGER. PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection) Elag — 11IIIII— o-5 C— O 1 XX -X xx' —xn 1 SUPPLY DIFFUSER 2 -WAY THROW RETURN GRKLE �Z A BALANCE DAMPER s SPIN N FITTING 5--r —, ECCENTRIC DUCT TRANSITION S--4 —J CONCENTRIC DUCT TRANSITION ►�� 11 FIRE i?AMPER - FD MOTOR OPERATED DAMPER - MOD CONTROL DAMPER - CD FUMBLE DUCT ROM) DUCT - LP ROUND DUCT - DOWN TEMPERATURE SENSOR T1ERMOSTAT DUCT MTD. SMOKE DETECTOR UNDERCUT DOOR UNiT HEATER (UH) ELECTRIC BASEBOARD WATER (EBBH) EQUIPMENT MIGNON CELIAC ELEVATiON PLLIMBIAG CODED NOTES WPC CODED NOTES SUPPLY DIFFUSER 4-WAY THROW STIFFLY DIFFUSER 3-WAY THROW SUPPLY DUCT - UP I1 SUPPLY DUCT - DOWN RETURN OR DXHL DUCT - UP RETURN OR DW. DUCT - DOWN ELBOW W/IURNNG VANES LEGEND AND SYMBOLS - LANDLORD INFORMATION - HEIGHTS UNAVAILABLE CROWN HRE PROTECTION, INC. ATM: JOHN ABEL 4832 WEST INTERURBAN BLVD. BOTHER L WASHINGTON 98012 PHONE: 425 - 481 -7669 FAX 425 - 481-8695 E - YAL: jabelOanrmfp.com EF-2 1/1 i- - SPRINKLER NOTES: MY SHUiDOWN OF THE FRE SPRINKLER SYSTEM REQUITES LANDLORD APPROVAL AND COORDINATION. T.G.C. WILL REIMBURSE LANDLORD FOR EACH SHUTDOWN. AIL SHUTDOWNS MUST BE PERFORMED BY TIE LANDLORD'S SPRINKLER CONTRACTOR. THE REMISED SPRINGER SYSiEIA SHALL BE DESIGNED AND INSTALLED BY THE LANDLORD'S APPROVED FIRE PROTECTION CONTRACTOR (AT TENANT G.C.'S DU ENSE) IN STRICT ACCORDANCE WITH THE REQUIREIENtS OF THE LANDLORD, LANDLORD'S FIRE INSURANCE LAIDERWRiTER, AND ALL GOVERNMENTAL AGENCIES AND ALJIHORTiES HAVING JURISDICTION OVER THE PREIMISES. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO THE LOCAL FIRE MARSHALL'S OFFICE MD BUILDING DEPARTMENT TO RECEIVE THEIR APPROVAL BEFORE ANY NSTALLAiiON CAN BEGAN. APPROVED DRAWINGS MI BE AT JOB SITE DURING CONSTRUCTION. TENANT'S CONTRACTOR SHALL NOTIFY CENTER MANAGEMENT PRIOR TO DEACTIVATiNG SPRINKLERS. SHOP DRAWINGS: THE SPRINKLER CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS TO LANDLORD AND APPROPRIATE AUTHORTI6 AND NAIRANCE UNDERWRITERS FOR APPROVAL A COPY OF TIE APPROVAL LETTER FROM THESE AUTHORITIES SHALL BE FORWARDED TO TENANT, LANDLORD AND DESIGN ARCHITECTS. THE FOLLOWING LANDLORD DESIINATED CONTRACTORS SHOAL. BE EMPLOYED BY TENANT G.C. TO PERFORM WORK N THESE AREAS: FiI ALARM CONTRACTOR: GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WASHINGTON 98383 PHONE: 360 -692 -3738 FAX 360- 692 -6857 E-MAIL BOB VEZZAI bvezzaniOgua>rclansecu f y.com MILAN: PONY MAURICE pma ur coOguardianeecurity.com SERMEUMIMAMEM PATRIOT FIRE PROTECTION, INC. COSCO FIRE PROTECTION ATTN: MARK FROMONG ATTN: PATRICK CARNAHAN 2707 70111 AVENUE EAST 15000 WOODUMLLE -AND RD. SURE 18 - 800 TACOMA, WASHINGTON 98424 W00DINVILLE, WASHINGTON 98072 PHONE: 253- 926 -2290 PHONE: 425 - 827 -9654 253- 284 -3535 425 -686 -6313 FAX: 253- 922 -6150 FAX 425 - 827 -4784 E -MAIL: rnarIcf0patriolfiriman E-MAL pcornahanOcoscofiracom WESTERN STATES FiRE PROTECTION CO. ATTN: WES HAMILTON 7102 180TH AVENUE NE. A-105 REDMOND, WASHINGTON 98052 PHONE: 425 - 881 -0100 FAX 425 - 881 -3030 E-MAIL veston.hamnonOrrsfp.oam LANDLORD REQUIRED CONTRACTORS OPEN TO DECK • //% r/ / / / / / / / /I 12 "x10""SA iii MEN MEE ■M■ 16 - x 14'SA SALES ENE M■ ■■■ I- --1 1 . f / 1 1 I 1 1 EXIST. 10 "0T.E. EXIST. 20 "x18" 1 1 EXIST. I 8'KT.E. } --- -� i FPI 1 EXIST 18 • - - - -- # EXIST. 10"0T.E • 6'oT.E. MECHANICAL PLAN STOCKROOM OPEN TO DECK EXIST. 20'x18' 1 8 ' - REFER TO PLUMBING PLAN SHEET M2.1 . THE CONTRACTOR FOR THIS DMSION OF WORK 15 REQUIRED TD READ THE SPECIRCATKOIS AND REVIEW DRAWINGS FOR ALL DMSIONS OF WORK AID IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL MASONS OF WORK. RIG THIS CONiRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENiS. 2. THE FNAC CONTRACTOR SHALL COORDINATE VATH THE GENERAL CONTRACTOR ON ANY ADDITIONAL STRUCTURAL. STEEL REQUIRED TO SUPPORT MECHANICAL EQUIPMENT PER DETAILS SHOWN ON STRUCTURAL PLANS. THIS CONTRACTOR SHALL COORDINATE LOCATIONS AND REQUIRMENiS WITH THE GENERAL CONTRACTOR AND LANDLORD. VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR PRIOR TO BID AND NCWDE ALL COSTS IN BID AS DIRECTED BY THE GENERAL CONTRACTOR 3. HVAC CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING MID DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. COORDINATE REQUIREMENTS WiTH THE GENERAL CONTRACTOR AND LANDLORD. REFER TO SPECFiCATIONS FOR ADDITIONAL. INFORMATION. VERIFY SCOPE OF WORK WTH THE GENERAL CONTRACTOR PRIOR 10 BID AND INCLINIE ALL COSTS IN BID AS DIRECTED BY THE (BIMETAL CONTRACTOR. 4. HVAC CONTRACTOR SHALL PROVDE AND INSTALL ALL EQUIPMENT AND MATERIALS, INWJOING AL PIPING AND DUCTWORK, AND MAKE ALL CONNECiIONS, PER THE DRAWINGS AND S'ECIRCATiONS. MN INDEPENDENT AIR BALANCE AND WPC SURVEY COMPANY SHALL CONDUCT A COMPLETE INSPECTION OF THE NSTALLATiON AND REPORT ANY DEVIATIONS FROM THE PLANS MID SPECIFICATIONS. THE INAC CONTRACTOR SHALL BE UIBLE FOR ANY DISCREPAN(M,S AND SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ANY CORRECTIVE ACTION REQUIRED. 5. T.G.C. SHALL PROVIDE FIRE EXI1NcUISHERS WHICH COMPLY WITH LOCAL FIRE CODE AND THE SPECIFIC INSTRUCTIONS OF LOCAL BUILDING OR RRE DEPARTMENTS PERSONNEL INSTALLATIONS SHALL COMPLY WITH NFPA #1O AND LOCAL REQUIREMENTS. MECHANICAL GENERAL NOTES EXIST. 8 "OT.E. I I I r I -- A1/21' of F.: 63°11°3 t l3QBS110 " ' a gYAMMOO Is adatow VERIFY ALL CONDITIONS IN FIELD PRIOR TO BIDS. SMOKE DETECTION NOTE: N OCCUPANCIES NOT REQUIRED TO BE EQUIPPED %ME A FiRE ALARM SYSTEM, ACf WMON OF A SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND AN AUDIBLE SIGNAL N AN APPROVED LOCATION. DUCT SAUCE DETECTOR TROUBLE CONTXHONS SHALL ACTNATE A VISIBLE OR AUDIBLE SIGNAL N AN APPROVED LOCATION AND SHALL BE DENTIFIED AS AR DUCT DETECTOR TROUBLE 0 MECHANICAL CODED NOTES NOTE CONTRACTOR IS TO VERIFY ALL CONDITIONS N THE FIELD PRIOR 1D BODING WORK. ANY CONDITIONS THAT AFFECT THE INSTALLATION OF THIS PROJECT MUST IMMEDLATELY BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION WINNER OR BE INCORPORATED N THE BID. DUCTWORK SHALL NOT BE FABRICATED OR ANY EQUIPMENT ORDERED PRIOR TO APPROVAL BY THE TENANT'S CONSTRUCTION MANAGER. . > ...:........ ..max NEW TiTUS MODEM. ATQS VAV BOX WITH 5kv ELECTRIC HEATING COL PROVIDED AND INSTALLED BY WPC CONTRACTOR. SEE SCHEDULE AND DETAL ON SHEET 1/20 FOR ADDITIONAL INFORMATION. TOILET EXHAUST FAN WITH BAKDRAFT DOPER FURNI5FED BY GYMBOREE AND NSTAJ.ED BY ELECTRICAL CONTRACTOR. FAN SHALL HAVE A CAPACITY OF 100 CFM 0 .35 S.P. TENANT'S GENERAL CONTRACTOR SHALL ROUTE NEW 6'I EXHAUST DUCT TO LANDLORD'S DOSING 8'• TOILET DITHAUST DUCT SiI B-N. FIEND VERIFY E7GIL' i WCARON. NEW VAV BOX CONTROLLER. MOUNT AT 48' A.F.F. COORDINATE FINAL WIRING RE7QUIREIMEN1S WITH LANDLORD AND ELECiTHICAL CONTRACTOR. PROVIDE AND INSTILL MANUWL VOLUME DAMPER AT DIFFUSER CONNECTION TO BRANCH DUCT DROP (FINICAL). NEW 2A -20BC RE EVER SUPPLIED AND INSTALLED BY GENERA. CONTRACTOR. COORDINATE EXACT QUMiTITY AND LOCATION WITH LANDLORD MD LOCAL FIRE MARSHAL NEW 1.5' INTERNALLY NSULAiED SUPPLY AR DUCT SUPPLIED AND INSTALLED BY WPC CONTRACTOR. PROVDE IRANSTIONS AS REQUIRED. DUCT DILENS10N5 ARE CLEAR INTERNAL AR PATH DIMENSIONS. EXISTING DUCTWORK MAY BE RE -USED F OF ADEQUATE SIZE AND IN GOOD CONDITION. VERIFY IN FIELD. HOLD ALL DUCTWQiI( AS I CH AS POSSIBLE/PRACTICAL N JOIST SPACE. ® FLEOBLE DUCT, MAXIMUM LENGTH 5'-0". TYPICAL PRcMDE SMOOTH TRANSITION AND PROPER SUPPORTS PER SMMNAI USE FLEX DUCT FOR FAA. RUN -OUT TO DIFFUSER ONLY. ® NEW SPINNER HEAD SUPPLJED AND INSTALLED BY LANDLORD'S DESIGNATED SPRINKLER CONTRACTOR AT TENANT G.C.'S EXPENSE (TYPICAL. COORDINATE EXACT LOCATION WITH NEW CEJI.NG AND UGHT FIXTURES. MODIFY SUPPLY PIING AS REQUIRED. ® NEW SPRINKLER HEAD SUPPLIED AND INSTALLED BY LANDLORD'S DESIGNATED SPRINKLER CONTRACTOR AT TENANT G.C.'S EXPENSE ON NEW TOILET ROOM CEILING. COOFDiNATE DUCT LOCATION WITH NEW UG HT/FMI FIXTURE MODIFY SUPPLY PIPING AS REQUIRED. 10 PROVIDE AND INSTALL TURNING VANES AT ALL SQUARE /RECTANGULAR DUCT ELBOWS (TYPICA). 11 THE GENERAL CONTRACTOR SHALL FURBISH AND INSTALL DRAWING TUBE HOLDER FOR STORAGE OF ALL CONTRACTORS 'AS- -BIALr DRAWINGS. FILE COPY Permit No. Pier review approval Is subject to emus end ant -4m City of Tukwila BUILDING DiVISION SEPARATE PERM` REQUIRED FOR: ❑ Mechanical 1YElsctric aI lumbing ig Gas Piping 62 C M CO M City of Tukwila o BUILDING DIViSIOk_ No chap REVISIONS 9es shall be made to the scope of work without prior approval of Tukwila Building NOTE~: Revisions will requir n ee w plan ?nd may include additional plan re submittal ew fees_ 1/4" = 1 t -0 " 1© LANDLORD'S DOSING SPRINKLER MAN WITH STUB -N. FEW VERIFY EXACT SIZE AND LOCATION. • LANDLORD'S EXISTING 32" x20' SUPPLY AR MAIN DUCT. FIELD VERIFY EXACT LOCATION. COORDINATE CONNECTION OF 14'0 DUCT TO NEW VAV BOX WITH LANDLORD. e TOILET ROOM DOOR SHALL BE UNDERCUT 3/4' (MIN.) TD FACILITATE RETURN AIR FLOW. COORDINATE WITH GENERAL C NIRAC'TOR. t15 LANDLORD'S EXISTING TOILET EX+W15T DUCTS. FiELD VERIFY EXACT LOCATIONS & SIZES. COORDINATE CONNECTION OF NEW TOILET OOHAUST DUCT MATH LANDLORD. • LANDLORD TO LEAVE DEMISING WALL 6' SHORT OF STRUCTURE FOR RETURN AIR FLOW BACK 10 LANDLORD'S VAV SYSTEM RETURN. COVER DURING CONSTRUCTION. t17 NEW SMOKE DETECTOR MI REMOTE TEST SWITCH MD LED INDICATOR LOHT SUPPLED MID INSTALLED BY HVPC CONTRACTOR. COORDINATE WIH LANDLORD MD ELECTRICAL CONTRACTOR. FINAL CONNECTIONS BY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR AT TENANT G.C.'S EXPENSE. 18 NEW 14"0 SUPPLY DUCT TO NEW VAV BOX. MAIM LENGTH 56'. COORDINATE EXPCr POINT OF CONNECTION WITH LANDLORD. INSULATE PER LANDLORD'S CRITERIA. RE- INSULATE LANDLORD'S EOSEING SUPPLY AR MAIN DUCT AS REQUIRED. FIELD VERIFY SUPPLY MR PRESSURE FROM LANDLORD'S MAN S.A. DUCT. LANDLORD'S DOSING 18x18' DOWERED SUPPLY AR DUCT POINT OF CONNECTION. FIELD VEIFY EXACT LOCATION. ADJUST FOR 2,510 CFM SUPPLY AIR. LANDLORD'S EXISTING 1611 DAMMED SUPPLY AR DUG? STUB-IN. FIELD VERIFY EXACT LOCATION. AVOID WITH ALL NEW CONSTRUCTION. CAP AS REQUIRED. NEW 16' x16' TRANSFER AIR GRILLE LOCATED ABOVE CELNG AS HIGH AS POSSIBLE/PRACTICAL COORDINATE W 1 I GENERAL CONTRACTOR FOR GYP. BOARD ROUGH-IN LOCATION. LANDLORD'S EXISTING 18"O TOILET EXHAUST DUCT UP. FIELD VERIFY EXACT LOCATION. LANDLORD'S EXISTING 811 TOILET EXHAUST DUCT STUB -IN. FELD VERIFY EXACT LOCAiiON. AVOID WITH ALL NEW OONISiRUCION. CAP AS REQUIRED. 0 GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHITECT, NCAF , ISP 195o CRAIG ROAD, SURE 300 ST. LOURS, 610 63146 PI{ (314) 415-2400 FAX (314) 415 -2300 www.ercv.cam REVIEWED FOR CODE COMPLIANC APPROVED A PR - 3 2008 CO CO C N N 0 0 C TY AP P : RN II FE : E � LA 0 12108 IT E TE fir ;!STEREO 'ECT •;= F C DEIiiLK J. COCOA STATE OF WASHINGTON MECHANICAL PLAN SHEET NUMBER: M1.0 LOCATION: SEATTLE, WASHINGTON BIOCKLOAD 4.15 CITY NAME LOCATION LATITUDE LONGITUDE ELEVATION SUMMER DESIGN DRY BULB SUMMER COINCIDENT WET BULB SUMMER DAiLY RANGE WINTER DESIGN DRY BULB CURRENT DATA IS TAG NEW VAV -1 DESIGN WEATHER DATA MR SYSTEM INFORMATION SYSTEM TYPE - FAN POWERED VAV BOX NUMBER OF ZONES - 1 SIZING CALCULATION INFORMATION ZONE AND SPACE SIZING METHOD ZONE CFM: SUM OF SPACE AIRFLOWS SPACE CFM: PEAK SPACE LOAD CENTRAL COOLING COIL SIZING DATA ABLE COIL (TONS) - 3.9 MAX. POSSIBLE CFM - 2,540 S D g ESIGNN SUPPLY /TON TEMP. (`F) - 55.0 - B11J�%HR /Sq.R. - 38.8 SUPPLY FAN SIZING DATA ACTUAL MAX. CFM - 2,540 STANDARD CFM - 2,540 ACTUAL MAX. CFM /Sq.Ft,. - 1.11 OUTDOOR VENiiL.ATION MR DATA DESIGN AIRFLOW (�) - 0.28 (THRU LL'S SYSTEM) ) TABLE 1. SIZING CALCULATION INFORMATION ZONE AND SPACE SIZING METHOD ZONE CFM: SUM OF SPAi.:E AIRFLOWS SPACE CFM: PEAK SPACE LOAD TABLE 2. ZONE SIZING DATA ZONE NAME SALES NOTE: ZONE LOADS CALCULATED AT OCCUPIED THERMOSTAT SETPOINT. AR SYSTEM DESIGN LOAD SUMMARY PEAK HEATING AT - WINTER DESIGN COOUNG OA DB/RH - 85.07/51.7X HEATING OA DB 23.0T PEAK COOUNG AT - JULY 15:00 ZONE LOADS WALL LADS (Sq.Ft. �TRA MISSION Sq.Ft ROOF TRANSMISSION Sq.Ft. GLASS ( TL TRANSMISSION (Sq.Ft.) ) E� ATM_ Ti5 ) PEOPLE VENTILATION (CFA) INFILTRATION WEN FACTOR PULLDOWN/WARM -UP PARTRLON (Sq.Ft) SUPPLY FM LOAD (cfm) PLENUM WALL LOAD PLENUM ROOF LOAD PLENUM UGH TING LOAD TOTAL SYSTEM LOADS NOTES: (1) ZONE LOADS CALCULATED AT OCCUPIED THERMOSTAT SET'POINT. (2) ZONE CONDITIONING BASED ON HEAT EXTRACTION ANALYSIS. (3) IN THE COOLING COLUMN, POSITIVE LOADS INDICATE HEAT GAINS WHILE POSITIVE COIL LOADS INDICATE SYSTEM HEAT REMOVAL (4) IN THE HEATING COLUMN, POSITIVE LOADS INDICATE HEAT LOSS, WHILE POSITIVE COIL LOADS INDICATE SYSTEM HEAT ADDMON. HVAC LOAD CALCULATIONS ROOM PUKE SALES smayErc. TOTAL FLOOR AREA SQ. FT. 1,703 523 - SEATTLE - WASHINGTON - 47.5 DEGREES - 122.3 DEGREES - 449 FT - 85.0'F - 65.0' F - 18.3' F - 23.0' F - CARRIER DEFAULTS COOUNG (M S BH 29.7 9.4 2,� N/A 20X /20X /20% 344 2006 IMC OUTSIDE AR REQUIEMENIS CFM PER CFM SQ. FT READ. 0.3 510 0.15 79 AIR SYSTEM SIZING SUMMARY COOUNG DETAILS (BTU/HR 2.OX OX 15X CALCULATION : J- F- M- A- M- J- J- A- S -O-N -D SIZING DATA: CALCULATED ZONE SIZING SUMMARY CALCCULATION MONTHS: J- F- M- A- M- J- J- A- S-0-N -D SIZING DATA: CALCULATED 0 0 0 18 7,746 0 8,105 4, 4 2,724 0 2,796 48,431 DESCRIPTION HVAC EQUIPMENT SCHEDULE S1fSTEM NUMBER VAV -1 OUTSIDE AIR REQUIREMENTS N3Vla 11 NONE LOAD OCCURS AT OA DB /WB CF) LEAVING COIL ADP BYPASS F RESULTING RH ACTUAL OUTSIDE AIR CFM PER UNIT N/A FLOOR AREA - 2,260 Sq.Ft. r CFM/PERSON - 16.38 DESIGN MONTH & HOUR JULY 15:00 JULY 15:00 COOUNG LATENT (BIU/HR) 0 0 0 0 7,790 0 0 1,558 0 9,348 0 0 NEW TUTUS MODEL #ATQS -7 FAN POWERED VAV BOX WiEN 5kw ELECTRIC HEAT COIL, INLET SIZE 14 2,550 FAN CFM 0 0.5 SP, 460v/3ph/4 -WIRE, 1 hp /277v MOTOR, 2,510 PRIMARY CFM (845 CPA MIN.) ACCESSORIES: MFR'S FILTER BRACKETS - JULY 15:00 - 85.0/65.0 - 77.9/632 - 53.6/52.3 - 50.9 - 0.10 - 48.0X DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE. TENANT SHALL MAINTAIN A MINIMUM OF 6' UNOBSTRUCTED CLEARANCE HEIGHT IN RETURN NR PLENUM ABOVE CEILING ALLOWING FOR AR FLOW BACK 10 LANDLORD'S NR CONDIiIONNG MT. LANDLORD PROVIDED A TENANT FIRE SERVICE MAIN WiTH BRANCH PIPING STUBBED INTO EACH TENANT'S SPACE LANDLORD'S SPRINKLER SYSTEM IS DESIGNED PER ORDINARY HAZARD GROUP 2 MID THE LATEST REQUIREMENTS OF SPA -13. NO ISOLATION VALVES WILL BE PROVIDED OR PERMITTED. TENANT SHALL CONNECT A FIRE SPRINKLER SYSTEM TO LANDLORD'S I KLER SYSTEM %RHIN THE DEMISED PREMISES USING APPROVED MECHANICAL FITTINGS. TENANT SHALL PROVIDE AND INSTAL AL BRANCH PiPING AND SPRINKLERS REQUIRED TO COMPLETE THE SPRINKLER SYSTEM WITHIN THE 1BINfT SPACE. TENANT'S WINKLER SYSTEM DESIGNS SHALL BE BASED UPON THE REQUIREMENTS OF THE STATE OF WASHINGTON, CITY OF TU KWILA FIRE DEPT. TENANT SHALL ENGAGE THE SERVICES OF A LANDLORD PREFERRED FIRE SPRINKLER CONTRACTOR TO DESIGN, PERMIT, AND INSTALL TENANT'S FIRE SPRINKLER SYSTEM N ACCORDANCE WITH THE BASE BUILDING DESIGN S E F1CATiONS. SPRINKLER LAYOUT AND AND PIPE SIZING SHALL BE HYDRAULICALLY DESIGNED ACCORDING TO ORDINARY HAZARD GROUP 2 MD 'THE LATEST REQUIREMENTS OF NEPA -13. Al SPRINKLER HEADS 14 TIE FORWARD SELLING AREA ARE TO BE CONCEALED POP OFF COVER TYPE. ALL SUPPORTS SHALL BE FROM STRUCTURAL BEAMS AND JOISTS, NOT FROM FLOOR OR ROOF DECK ABOVE. TENANT'S CONTRACTOR SHALL INSTALL ML INSPECTORS TEST CONNECTION, PIPED TO A FUNNEL DRAIN, (WITH WET TRAP), MOUNTED 3' -0' A.FF.. INSTAL A 1" CORROSION RESISTANT SHUT -OFF VALVE TENANT SHALL INSTALL A VANE TYPE WATERFLOW DETECTOR IN THE MAIN SPRINKLER LINE IMMEDIATELY AFTER CONNECTION TO THE LANDLORD'S MAN, WHICH IS CONNECTED TO THE LANDLORD'S FIRE ALMA SYSTEM. DO NOT ATTACH ANYTHING DIRECTLY TO SLAB OR ROOF DECK ABOVE MAXIMUM LENGTH OF FLEX DUCT IS 5'-0'. • LANDL • RD NOTES 9 SALES VIDEO MONITOR SR -1 RG-1 RG-2 821 RF445T RH45 SIZE MOO. NECK 24'x24" 1O'9 18'x8' 24'x24' 22'x22' 18"x18' 16'x6' 16'x16' 500 W. 205 W. 225 W. 480 W. 8013 W 2013 W. 30 KVA • DUCT MM WALL MTD 500 W 205 W. 225 W. 400 W. 300 WI 120 W. 800 W. TOTAL ELEC. EQUIP. • . WATTS 1 500 • 2 B B B 1 120 • • B A C A A 1 1 1 • MOUNTING I ATERAL BORDER CEILING OTHER STEEL ALUM. SiYLE A C A WATTS 205 400 300 1,705 8 REMARKS HEATING 0 0 0 0 0 0 241 1,204 -609 0 0 551 HEATING (BH) 0.0 1.4 OA THRU LL'S SYSTEM (LAC-1F). 12,395 TOTAL CFM/3,100 MIN. CFM/2,170 OA CFM NONE EQUIPMENT NAME NEON SOUND CASH PC MICRO E AIR OEVI NOTES : 1. SV11B FIRST SE 2. CAT, 3. PRO 4. w�SH ' TAG SD-1 N.E.C. REQ. 10 AIR DEVICE SCHEDULE H.VAC. LOAD NON SALES E CONTROL REMARKS MR VOLUME DAMPER FURNISHED WITH SUPPLY REGISTER ROOK= JOIST �� - HANGER WIRE DUCT HANGING DETAILS AJti N SECTION DUCT MOUNTED SUPPLY REGISTER ALL DUCT LINER TRANSVERSE EDGES TO BE COATED W/ ADHESIVE IN ACCORDANCE W/ WAWA STANDARDS C•) ROUND RLGD DUCT- TAPE ATI DDCTERNAL INSULON FASTEN W/ MIN. (3) SHT. MiL SCREWS, SEAL W/ DUCT TAPE AND MASTIC 1 1/2' WRAPPED INSULATION ROUND DUCT TAKE -OFF DETAIL ROOF JOIST �.� HANGER WIRE - 33 SHEET MTL DUCT HANGER SPIRAL DUCT EXTERNAL INSULATION SHALL BE RUN CONTINUOUS THRU SHEET MTL DUCT HANGER RECTANGULAR DUCT EXTERNAL INSULATION SHALL B RU CONTINUOUS THRU p/A SUPPLY REGISTER SURFACE MOUNTED TO DUCT THE CONTRACTOR IS TO ADJUST THE SIDE LOUVERS EACH DIRECTION TO 30' N THE SUP IS TO ADJUST LOUVERS TO 20' iN FLANGED MID METED JOINT OR DUCT CONNECTION MID RE- ENFORCEMENT N ACCORDAI4CE W/ SMACNA 2' W.G. CLASS, SEAL NON-GASKETED TRANS- VERSE JOINTS IN ACCORDANCE W/ SMACNA CLASS 'C' (TYP.) MAN DUCT AUL 1 1 Z" ACOUSTICAL CONICAL OR BEIIMOUTH IN MEND SEAL MIGHT WI MASTIC VOLUME DAMPER WITH LOCI•IG QUADRANT. PROVIDE WITH 3" EMENDED SHAFT, HANDLE MID COLLAR DAMPER HANDLE TO BE NSTAJED MAXIMLP4 OF 3'-0' ABOVE CEDING. EXISTING BELL MOUTH OR CONICAL TAP BY LANDLORD - LANDLORD'S -\ S.A. DUCT J BY LANDLORD fTO SA WAN INSULATED FUMBLE CONNECTION OAK 3 FT., MAX. 4 FT.) ARE DMPER %IMRE INDICATED ON PLANS. DIRECTIONAL BLOW PLATE CLIPPED ON DIFFUSER RODS. SEE NOTE BELOW. VAV SUPPORT DETAIL 4 DUCT DIAMETERS (MIN.) STRAIGHT SECTION SHALL BE SAME SIZE AS VAV BOX INLET (FLEXIBLE DUCT SHALL NOT BE ALLOWED) NEW VAV BOX IL BY TENANT ,N>«. «1,««.10«,«««X« J ROOM THERMOSTAT NONE SUPPLY AIR DIFFUSER (LAY-IN FRAIiE) DIFFUSER INSTALLATION DETAIL REVIEWED FOR CODE CCM APR - 3 2110 City Of Tuikwila B ILO NO 01 VISI •fi li.... w.cxaaxacwacua�ww v a 4{1iNi I,ii. „a.axaww roX[.mweu «.d...a «.aaMM + xae «wew:aeaze.Nuaamwweexa«xii.... :., wxaa,Naawa :avw,,X.NWO n:aU NONE REVISION Na_ SHE MiL ELBOW REQUIRED THERMAL NSULA11NG BLANKET REQUIRED FOR FIRE RATED CEILINGS ONLY. SECUREY TAPE VINYL FLEX DUCT TO SHT. MiL WI LIN. OF (2) CONTINUOUS WRAPS OF DUCT TAPE. STRAP CLAMP OVER FIE( DUCT INSULATION & VINYL TO SHT. MiL TAPE INSULATION TO DUCT TO FORM A GOOD SEAL 8' LONG SHT. MiL SECTION SECURED TO DIFFUSER COLLAR W/ MIN. (3) SHE. MiL SCREWS, DUCT TAPE AND MASTIC. TRANSITION FROM DUCT SIZE TO DIFFUSER NECK SIZE AS NECESSARY DRYWALL CLG. STEEL MOUNTING FRAME REQUIRED FOR DRYWALL CARING INSTALLATION SEE DETAIL THIS SHEET. NOTE ALL DIFFUSERS SHALL HAVE 4-WAY FACE PLATES WITH INTERNAL CITY OF TUKWILA SECTORING BAFFLES FOR AIR PATTERN SHOWN. PROVIDE WiTH THROW REDUCING VANES. 1 -WAY, 2 -WAY & 3-WAY ARE DESIGNATED AP R 0 1 2008 ON PLANS BY SHADED AREA IDICATiNG INACTIVE SECTION. PERMIT CENTER GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHITECT, NCARB, {5P S50 CRAIG ROAD, SLATE 300 ST. LOIN, MO 63146 PR (314) 415 -2400 FAX (314) 415-2300 wwwsrcv.cam w co CO = M z w cc CO CO CO ON LC) N 0 SHEET NUMBER: 6897 \ r 1 ; rrtJ J a•-v `fir HVAC DETAILS & SCHEDULES M2.0 MOQO'-f1 m cf `cf) W cO DMSION 15000 - MECHANICAL SECTION 15001 - BASIC MECHANICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DMSION 15000. 2. THE CONTRACTOR FOR THIS DMSION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DMSIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 15002 - GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR GYMBOREE SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE GYMBOREE PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCESS PANELS FOR SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES USTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 15003 -- CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL. INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY GYMBOREE TO THE CONTRACTOR. SECTION 15004 -- LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. 2. FURNISH TO GYMBOREE'S PROJECT MANAGER ALL CERT RCATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 15005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY GYMBOREE'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. MECHANICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO GYMBOREE'S PROJECT MANAGER FOR APPROVAL SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR GYMBOREE'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF GENERAL CONTRACTOR AND THE SUBCONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. SECTION 15006 - GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY GYMBOREE'S PROJECT MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. GYMBOREE SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY GYMBOREE AND GYMBOREE'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONEYS SHOULD BE INCLUDED IN THE BID. MECHANICAL SPECIFICATIONS SECTION 15007 - RECORD DRAWINGS 1. This CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. B. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. C. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED TO GYMBOREE'S PROJECT MANAGER. SECTION 15008 - DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE GYMBOREE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, GYMBOREE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SECTION 15009 DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. EACH CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING FIRE PROTECTION, PLUMBING FIXTURES, PIPING, HVAC UNITS, REFRIGERANT RECAPTURE, EXHAUST FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPUCABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND /OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND GYMBOREE PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND GYMBOREE. SECTION 15010 - CUTTING AND PATCHING 1. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. 2. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FINISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND GYMBOREE'S PROJECT MANAGER. 3. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND GYMBOREE'S PROJECT MANAGER. SECTION 15011 - SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2' ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRAWNG OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RN" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEIUNGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. SECTION 15012 - HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CUPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. DMSION 15300 - FIRE PROTECTION (IF APPUCABLE) SECTION 15301 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPUED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. INSTALLATION OF NEW WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE , NFPA -13, LOCAL CODES (STATE OF WASHINGTON, CITY OF TUKWILA FIRE DEP'T.) AND LANDLORD'S CRITERIA. 2. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. 3. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. 4. PERMITS, FEES, INSPECTIONS AND CHARGES. 5. TESTS AND TEST CERTIFICATES. IT IS INTENDED THAT THE CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM. B. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, HYDRAULIC CALCULATIONS, HEAD TYPES AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. SECTION 15302 - MATERIALS A. SPRINKLER HEADS: 1. ALL SPRINKLER HEADS SHALL BE NEW U.L, F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY GRINNEEI„ RELIABLE, STAR, OR VIKING. ALL SPRINKLER HEADS SHALL BE USTED FOR APPLICATION INSTALLED FOR. 2. ALL SPRINKLER HEADS SHALL BE RATED FOR 165T UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3. VERIFY HEAD TYPES AND COLORS WITH GYMBOREE AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY GYMBOREE AND THE LOCAL FIRE PROTECTION OFFICIAL BEFORE INSTALLATION. A. SALES/TOILET ROOMS - FULLY RECESSED WITH OVER PLATES B. STOCKROOM /CORRIDOR C BRASS PENDANT C. STOREFRONT - FULLY RECESSED HEADS WITH COVER PLATES. B. PIPING: 1. SCHEDULE 40, BLACK STEEL PIPE, ASTM A -53 FOR FERROUS PIPING, WELDED AND SEAMLESS, ANSI B- 36 -10 -70 FOR WROUGHT STEEL PIPE. 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD GROUP 2 - HYDRAULICALLY DESIGNED. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. E. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS DESIGN AND INCLUDE ALL COSTS TO RAISE OR RELOCATE EXISTING PIPING TO OBTAIN CEILING HEIGHTS SHOWN ON DRAWINGS. IN NEW CONSTRUCTION THE LANDLORD MAY PROVIDE ONLY A STUB -IN TO THE SPACE. THE CONTRACTOR SHALL CONNECT AND EXTEND NEW PIPING AS REQUIRED. VERIFY ALL REQUIREMENTS PRIOR TO BID. F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR GYMBOREE'S INSURANCE CARRIER. G. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY THEM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. H. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, AND AUTHORITIES HAVING JURISDICTION. DIVISION 15400 - PLUMBING SECTION 15401 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPUED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE PLUMBING SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, SHOWN ON DRAWINGS AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING WATER SUPPLY AND DRAIN UNES AND MAKE PROPER CONNECTIONS, THERETO, INCLUDING VENTS. 2. ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFY ALL DIMENSIONS AT THE SITE. 3. ALL VALVES, CLEANOUTS, ETC. SHALL BE SO LOCATED AND INSTALLED TO PERMIT ACCESS FOR SERVICE WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS. SECTION 15402 MATERIALS A. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE ARE CONSIDERED ACCEPTABLE AS EQUALS. ALL PLUMBING EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION. B. SANITARY PIPING 1. WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE WITH NO HUB COUPLINGS. VENT PIPING ABOVE FLOOR 1 -1 /2" OR SMALLER MAY BE GALVANIZED STEEL 2. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. 3. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBE WITH 95 -5 TIN- ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. EXTERIOR CONDENSATE PIPING MAY BE SCHEDULE 40 PVC PIPING WITH SOLVENT WELDED FITTINGS IF APPROVED FOR USE BY THE LANDLORD. C. POTABLE WATER PIPING 1. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. 2. ALL OTHER: TYPE 'L' HARD DRAWN COPPER TUBE WITH SWEAT JOINTS AND CAST WROUGHT COPPER FITTINGS AND 95 -5 TIN - ANTIMONY SOLDER. D. PIPING OF DISSIMILAR METALS MUST BE DI- ELECTRICALLY SEPARATED. E. INSULATE ALL HOT WATER, COW WATER AND INTERIOR CONDENSATE PIPING WITH 1 THICK (K =0.23 ® 75 F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. OWENS - CORNING OR EQUAL F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W WHITE "HAND! LAV GUARD" INSULATION KIT TO COMPLY WITH A.D.A. REQUIREMENTS. G. INSTALL AIR CHAMBER SHOCK ABSORBERS IN BOTH HOT AND COLD UNES OF PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. SIOUX CHIEF 650 SERIES ALL STAINLESS STEEL, OR EQUAL J.R. SMITH "HYDROTROLS ", INSTALLED IN AN UPRIGHT POSITION. H. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. I. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING INSTALLED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. J. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. K. CLEAN -OUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. ALL FLOOR DRAINS SHALL HAVE DEEP SEAL TRAPS. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. L ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS, AND CEIUNGS IN FINISHED AREAS. M. LEAKAGE TESTS SHALL BE PER LOCAL CODES. N. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPUCABLE AND INCLUDE ALL COSTS IN BID. 0. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPUCABLE. REVIEWED FOR CODE COMPLIANCE APPROVED AP R - 3 205 C3F kwlla B ILDING DIVISION RECEIVED CITY OF TUKWILA APR 012008 TER a 011136D2 GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. G0GLIA ARCHITECT, NCARB, ISP 1950 MAIQ ROAD, SUITE 300 ST. LOUIS, MO 63146 P14 (314) 415 -2400 FAX (314) 415-2300 wwwercv.com 62 C co CO w CO OD CV N J W< W M J J Ce LLJ C4 co ® Z z co CO W U = H I- D 0 = CD Y/ T r 0 ac 0 0 629/ I ?ti. C1 SHEET NUMBER: M3.0 ao 50 gifi MECH. SPECS/ RESPONSIBILITY SCHEDULE REVISION NOt M68 -Oyu E. FLEXIBLE AIR DUCT AT AIR DEVICES SHALL BE 1" INSULATED CLASS 1 AND RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL MUST ADHERE TO LOCAL CODES AND LANDLORD'S REQUIREMENTS. F. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, REUEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. G. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. FIRE DAMPERS SHALL BE UL LABELED. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 F FUSIBLE LINK, TYPE B, AS MINIMUM. H. DUCTWORK INSULATION 1. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90k 2. DUCT SIZES SHOWN ON DRAWINGS DO NOT INCLUDE INSULATION. ALL SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1 1/2" THICK, DUCT WRAP INSULATION PER LL'S CRITERIA. 3. ALL ROUND, MEDIUM PRESSURE AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 2" THICK, 1 LB. DENSITY (R =5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAT 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411, OR AS REQUIRED BY LOCAL CODES. MECHANICAL SPECIFICATIONS (CONTINUED) K. TESTING, ADJUSTING, AND BALANCING 1. TESTING, ADJUSTING AND BALANCING OF ALL WORK SHALL BE MADE BY LANDLORD'S DESIGNATED CONTRACTOR AT TENANT G.C.'S EXPENSE. 2. THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: A. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. C. INSTRUMENTATION UST WITH LAST CALIBRATION DATES. D. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. E. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. F. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. G. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. H. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOUNG WITH MINIMUM OUTSIDE AIR. RETURN /RELIEF /SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. I. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). K. INDEXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3 -WAY OR 2 -WAY. L FINAL BALANCED GPM AT ALL UNITS FOR CHILLED /HOT /CONDENSER WATER WHEN APPUCABLE. M. CHILLED /HOT /CONDENSER ENTERING AND LEAVING WATER TEMPERATURES WHEN APPUCABLE. N. PRESSURE DROP THROUGH COILS AND CONTROL VALVES WHEN APPUCABLE. 3. THE GENERAL CONTRACTOR SHALL ARRANGE FOR THE TEST AND BALANCE A MINIMUM OF TWO WEEKS PRIOR TO THE REQUIRED DATE AFTER RETURNING TABC'S 'START UP CHECK UST". ALL WORK SHALL BE COMPLETED PRIOR TO SCHEDULING AIR BALANCE. IN ADDITION, THE BALANCE CONTRACTOR WILL INSPECT AND PREPARE A FINAL PUNCH UST. THE HVAC CONTRACTOR SHALL REPAIR OR REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP PRIOR TO GYMBOREE'S FINAL WALK THRU AND BEFORE FINAL PAYMENT WILL BE MADE. 4. FOUR COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED TO GYMBOREE AND FOUR COPIES TO THE LANDLORD FOR APPROVAL ITEM V.A.V. BOXES DIFFUSERS AND GRIUES LOW PRESSURE DUCTWORK HIGH/MEDIUM PRESSURE DUCTWORK lEMPE INURE c N1RROLL SYS7EA1 TOILET EXHAUST FAN(S) AIR BALANCE REPORT — TABC AS —BUILT DRAWINGS ITEM PLUMBING FIXTURES SAN, OW, HW, PIPING WATER HEAIER AND ACCESSORIES AS —BUILT DRAWINGS ITEM SPRIT ER PIPING AND HEADS FIRE CCIINGUISHERS AS —BUILT DRA#NGS HVAC RESPONSIBILITY SCHEDULE GYMBOREE • G1LBOREE GIIMOREE FURNISHED BY LANDLORD PLUMBING RESPONSIBILITY SCHEDULE FURNISHED BY LANDLORD CONlR. • • • • • • • COMB. • • • • FURNISHED BY CON1R. • • • INSTALLED BY LANDLORD roan INSTALLED BY LANDLORD FIRE PROTECTION RESPONSIBILITY SCHEDULE INSTALLED BY LANDLORD CONMR. • • • • • • COMB. • • • COMB • • RE -USE EXISTING RE -USE EXISTING RE -USE EXISTING N/A N/A N/A VAV BOX SEQUENCE OF OPERATION: OCCUPIED 1. IF THE SPACE TEMPERATURE GOES ABOVE THE OCCUPIED COOLING SETPOINT, THE CONTROLLER WILL POSUON THE PRIMARY MR VALVE TO MAINTAIN THE PRIMARY AR VOLUME AT THE PRIMARY AIR VOLUME SETPOINT. THE PRIMARY AIR VOLUME SETPOINT WILL BE RESET BY THE CONTROLLER BASED ON CALCULATED COOLING LOAD AND WILL BE SET BETWEEN THE PRIMARY DEADBAND AND THE PRIMARY MAXIMUM VOLUME SETPOINTS AS REQUIRED TO MAINTAIN THE OCCUPIED COOLING SETPOINT. 2. AS SPACE TEMPERATURE FALLS BELOW THE OCCUPIED COOLING SETPOINT, THE CONTROLLER WILL ENTER DEADBAND MODE AND THE PRIMARY AIR VALVE WILL BE POSITIONED TO MAINTAIN THE PRIMARY AIR VOLUME AT THE PRIMARY DEADBAND VOLUME SETPOINT. 3. AS THE SPACE TEMPERATURE FALLS TO THE OCCUPIED HEATING SETPOINT, THE CONTROLLER WILL ENTER HEATING BAND. IF THE VAV BOX IS RECEMNG WARM NR FROM THE AHU, THE CONTROLLER WILL POSITION THE PRIMARY AR VALVE TO MAINTAIN THE PRIMARY AR VOLUME AT THE PRIMARY AIR VOLUME SETPOINT. THE PRIMARY AR VOLUME SETPOINT Will BE RESET BY THE CONTROLLER BASED ON CALCULATED HEATING LOAD AND WILL BE SET BETWEEN THE PRIMARY DEADBAND AND THE PRIMARY MAXIMUM VOLUME SEIPOINT AS REQUIRED TO MAINTAIN THE OCCUPIED HEATING SETPOINT. IF THE VAV BOX IS RECEMNG COLD AR FROM THE AHU, THE PRIMARY AR VALVE WILL REMAIN AT THE PRIMARY DEADBAND VOLUME IF REHEAT IS DEFINED IN THE CONTROLLER, IT WILL BE STAGED AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT OCCUPIED HEATING SEIPOINT. UNOCCUPIED THE PRIMARY AR VALVE WILL RETURN TO ITS NORMAL POSITION AND ANY STAGES OF REHEAT SHALL FUNCTION IN SETBACK. REMARKS REMARKS REMARKS RECEIVED CITY OF TUKWILA APR 012008 PERMIT CENTER XSA:MMS,, ‘ GYMBOREE CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHTECT, NCARB, ISP 1950 CRAIG ROAD, SUITE 300 Sr. LOUTS, MO 63146 PH. (314) 415 FAX (314) 415-2300 www.arcvcom mCO M W 0 o c.1 u, r r— N a 0 SHEET NUMBER: t: 689/ RF•G! % M3.1 x co cp ti MECH. SPECS./ RESPONSIBILITY SCHEDULE REVISION NO. 1M68- 097