Loading...
HomeMy WebLinkAboutPermit M08-056 - BOEING #9-99BOEING #9.99 9725 EMWS M08-056 Parcel No.: 0003400018 Address: Suite No: doc: IMC -10/06 Cit31111f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 9725 EAST MARGINAL WY S TUKW Tenant: Name: BOEING #9 -99 Address: 9725 EAST MARGINAL WY S , TUKWILA WA Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 - 00 Contact Person: Name: JOHN EIMER Address: 13301 SE 26 ST , BELLEVUE WA Contractor: Name: SHINN MECHANICAL Address: 13301 SE 26 ST , BELLEVUE WA Contractor License No: SHINNMIO60QP Value of Mechanical: $29,000.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial MECHANICAL PERMIT DESCRIPTION OF WORK: FURNISH & INSTALL (2) CHILLED WATER FAN COIL UNITS, CHILLED WATER PIPE, AND DUCT WORK. EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 1 0 0 0 0 0 0 0 0 * * continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 206 510 -9665 Phone: 425 - 373 -9800 Expiration Date: 11/19/2009 M08 -056 03/11/2008 09/07/2008 Fees Collected: $496.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 M08 -056 Printed: 03 -11 -2008 Permit Center Authorized Signature: Signature: Print Nam doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us LyiLL, Th,JL Permit Number: MO8 -056 Issue Date: 03/11/2008 Permit Expires On: 09/07/2008 Date: 3-11-08 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the perf • :;; ance of • . I am authorized to sign and obtain this mechanical permit. 7 W 1= ;m E /( Date: 3 i/-- z), This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -056 Printed: 03 -11 -2008 • City of Tukwila Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Suite No: Tenant: BOEING #9 - 99 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 5: Readily accessible access to roof mounted equipment is required. PERMIT CONDITIONS Permit Number: M08 - 056 Status: ISSUED Applied Date: 02/26/2008 Issue Date: 03/11/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 13: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 14: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of doc: Cond -10/06 M08 -056 Printed: 03 -11 -2008 such condition or violation. doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us * *continued on next page ** • 17: These plans were reviewed by Inspector 514. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. M08 -056 Printed: 03 -11 -2008 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: \ 1-60 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us doc: Cond-10/06 M08 -056 Date: : _ / / — c', ordinances governing or local laws regulating Printed: 03 -11 -2008 Site Address: Tenant Name: Property Owners Name: Mailing Address: Name: oti,L) 12— Mailing Address: 01 Company Name: Mailing Address: CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila. lra. tts Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Jt -7W.F At l"A— to , TACT PERSON who'do contact when your perm itli ready;to be ssue E -Mail Address: HiL J 1/411 L'fl ff . GcM -7� F hors ,)U- et, , King Co Assessor's Tax No.: OOD '` 4-©OO 1 g Suite Number: :D6r ? Floor: New Tenant: ❑ Yes ..No Day Telephone: oZ.7, Cl/;c,�.aIL 6o46(0 State Zip State Zip Fax Number: [�/W -, 373 3 T * ity GENERA I. CONT F .._, , -'s, .mation ....^. • t�° -< e�(Contractor lnfor,for Mechaoical{(pg :4) for,l'lumbing GasgPlpmg (pg 5))l Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHIeTECT'OFt,REC City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip '.ENGINEERxO RECOR] d �"•`. a �, "rs. 'N. s� kit — ,g:,•w t ,� �cu y - .i:.� - - 'e,'°�'�a� `®' . Alkplan must beiwet stampedrby Angmeer ofaRecord ;. . Y i.. 0 4 e .!'i .std:r ”;.,.. : .. Company Name: 7II r 26- 4 ` Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Q:\Applications\Fot ms- Applications On Linel3 -2006 - Permit Application.doc Revised: 9 -2006 bh State Zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System �' Incinerator - Domestic Other Mechanical Equipment G 6 2. Air Handling Unit <10,000 CFM Incinerator — Comm/Ind 7 /OD Lern') • ;MECHA -RMIT IIVFORMATI 64: • MECHANICAL CONTRACTOR INFORMATION Company Name: �j//) / J A) in I Ii44 Mailing Address: 13 3D / 5, ZIoT 5 / • 1 3 //i1-Lim 9 /2 Tege o4- City State Zip Contact Person: T O/l L '= t 141 OA, Day Telephone: e41=5 4 6,7 _3 E -Mail Address: AL)® 55, e.49/4 - Fax Number: e 405-) • 3 4¢9 Contractor Registration Number: 91,1 / 1t) Iv M n 6,0 6Z1:;" Expiration Date: 'l / /4 — DC Valuation of Mechanical work (contractor's bid price): $ 2q, DOO Scope of Work (please provide detailed information): AN/g f //) 9779-L L C27 G// I 4L540 rids. i Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ... Replacement .... ❑ Fuel Type: Electric Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Q:W pplications\Forns- Applications On Line') -2006 - Permit Application.doc Revised: 9 -2006 bh Page 4 of 6 ip •+aw:.< . _ _ _.: :. .. . 4 ,Y,�:a ) �.� . , �. x :�'t < ` °'�..:,vx .?a'i.`.Y•c° - a; �3 PERMIT APPLICA�TI NOT =E E.PP. 1 f �" ` a�' `� ,„±, � a , 3 �� p p ali e�.fo all. permlts� m�thls� a ; �� `'' '- ;`''. -. 'ul+•« ..c::t-'Al S. i!^+``. iigir it i'it:,.".c�'s:l .,t e� '' 2: n'+'r K ' '. S . ��"zh�'� "t ..,,�. it`m��G, +-,c. �i '�.. Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN I R,. THO AGENT: Signature: Print Name: - 'Qf/L, g-1 y'yf dF.A Mailing Address: Date Application Accepted: oeLl94 l � QMpplications\Forms- Applications On Line\ -2006 - Permit Application.doc Revised: 9 -2006 bh Date: Day Telephone: (40.5 ) tvv4 9pO3 5 4- City State Zip Date Application Expires: Staff Initials: Page 6 of 6 Receipt No.: R08 -00705 Payee: SHINN MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us Payment Check 028805 396.25 TRANSACTION LIST: Type Method Descriptio Amount RECEIPT Parcel No.: 0003400018 Permit Number: M08 -056 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 02/26/2008 Applicant: BOEING #9 -99 Issue Date: Initials: WER Payment Date: 03/11/2008 01:59 PM User ID: 1655 Balance: $0.00 Account Code Current Pmts 000.322.102.00.0 396.25 Total: $396.25 Payment Amount: $396.25 9757 03/11 ' TOTAL 396.25 doc: Receiot -06 Printed: 03 -11 -2008 Receipt No.: R08 - 00537 Initials: JEM User ID: 1165 Payee: SHINN MECHANICAL ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 0003400018 Permit Number: M08 -056 Address: 9725 EAST MARGINAL WY S TUICW Status: PENDING Suite No: Applied Date: 02/26/2008 Applicant: BOEING #9 - 99 Issue Date: TRANSACTION LIST: Type Method Description Amount Payment Cash 100.00 Account Code Current Pmts 000.322.102.00.0 .75 000/345.830 99.25 Total: $100.00 i Payment Amount: $100.00 Payment Date: 02/26/2008 11:27 AM Balance: $396.25 9116 02/26 9710 TOTAL 100.00 doc: Receiot -06 Printed: 02 -26 -2008 Project Type of Ins tion: Address: 7, S ' /z ' ggi,) Date Called: / Special Instructions: / Date Wanted: ` " --e9Z �m, p.m. Requester: Phone No: ,.2C' — 2-6 3–.- -- 7 / INSPECTION NO. INSPECTION RECORD Retain a copy with permit >l ? f Z9 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: pef ,k t Inspector k A "\\( �1 Date: / 0 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: S._va+ '�- a4S�.�+9x.w -a,a'S : ?::: ••.! ��. �:..:� ?�a ir,►..ae,.es!�e:sa.a$.ss a1!'r�ssw�'ma - COMMENTS: Type of Uspection: r RI)/ /i`1itJ Address: 972%5 fin..57 l?i ei p� lk - - (1 — R SJ\ f\ VJ CA I it g � , P � ' ^ ' G & Jr * p.m k 0bt1 A ( k,„ pi' d t i i-P. J.-• , c.: -....t 4 Projec • 6#0f / Type of Uspection: r RI)/ /i`1itJ Address: 972%5 fin..57 l?i ei Date C Iled: A Special Instructions: / Date Wanted: �✓ ' Q p.m Requester: Phone O : G -5 7/-2 WO • El $58.00 REINSPECTION FE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. CITY OF TUKWILA BUILDING DIVISION f' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION NO. Approved per applicable codes. Corrections required prior to approval. Date: Receipt. No.: Date: • INSPECTION RECORD Retain a copy with permit PERMIT NO. • Project: ,(0e, 00 63, 9 ei Fire Alarm: Type of Inspection: Address: e-T 0 Suite #:' G. w\ .0.) • - 23 Contact Person: Special Instructions: Phone No.: qa-c - 23.- ga-al Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER x:'�4a . u�3..kr ...a::.w::.:.t.�.::1= �'C:._.. _:'�...SGr::..._.: ...Sti+zmE..:.-�:m..acaYk :.� . �`, ; eA`._ �i6.. YY70ms�, a.., �w. .'w•a.�.a�u'�.�'�.' —:� w- „r= .._�. -.4” f Et -Approved per applicable codes. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT PERMIT NUMBERS 206 - 575 -4407 Word/Inspection Record Form.Doc 1/13/06 Corrections required prior to approval. COMMENTS: "›2 o d9 -- /M o - C.754 Inspector: (-. it-f Date: 51/a/ i52 Hrs.: n $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. "Form F.P. 113 ACTIVITY NUMBER: M08 -056 DATE: 02 -26 -08 PROJECT NAME: BOEING #9 -99 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil g "Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW/ROUTING SUP n mg, 2 -21 -O6 Fire Prevention Structural Incomplete TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Permit Coordinator DUE DATE: 02 -28-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DUE DATE: 03-27-08 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License SHINNMI060QP Licensee Name SHINN MECHANICAL INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601585839 Ind. Ins. Account Id #6 Business Type CORPORATION Address 1 13301 SE 26TH ST Address 2 City BELLEVUE County KING State WA Zip 980054204 Phone 4253739800 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 11/17/1994 Expiration Date 11/19/2009 Suspend Date Separation Date Parent Company Previous License Next License JEMCOI *984CF Associated License Business Owner Information Name Role Effective Date Expiration Date SHINN, MIKE D Cancel Date 01/01/1980 Bond Amount Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #6 HARTFORD FIRE INS CO 52BSBDN1736 11/17/2005 Until Cancelled $12,000.00 11/03/2005 UNITED STATES Until Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SHINNMI060QP 03/11/2008 CONTROL VALVE SCHEDULE TAG TAG LOCATION EQUIPMENT SERVED SERVICE FLOW Cv END CONNECTION BODY (CAST) SIZE ACTUATOR OUTLET (PSIG) BASIS OF DESIGN REMARKS 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR T -1 MANUFACTURER MODEL CV -1 HIGH BAY AHRB2 STEAM 810 OR 16 THREAD IRON 1 1/4" ELECT AHRB2 SIEMENS 999 30 PSI STEAM / 8 PSI DROP. TWO - POSITION NORMALLY CLOSED ACTUATOR 15 CV -2 HIGH BAY AHRD3 STEAM 810 #'HR 16 THREAD IRON 1 1/4" ELECT 30 SIEMENS 999 30 PSI STEAM / 8 PSI DROP. TWO- POSITION NORMALLY CLOSED ACTUATOR 1" -3 CV -• . H B• HIG "AY� eHRD2 _ T AHL': EAM ' ST • y r . 811 ; HR ":10 # "r• 16 .v. •EAD T THR3- :•N IRO " 1/4" 1 1' " EL ECT T ENS T SIEM 999 ' '''' " ' 31 *SI ST A / 8 • I DR•• TWO- ••SITIO LORMA CLOS I •CTUA •: 0 PSI' STEAM "8 PSI !,`OP. " s -POS •N NO`�•LLY C'" ED A ■ATOR 'Iv FLOAT & THERMOSTATIC T CV -5 C -3 EC-1 CHILLED WTR 3 GPM 1.9 THREAD BRASS 1/2" ELECT FLOAT & THERMOSTATIC BELIMO B210- LF24 -SR US FURNISHED ON OMEGA CONTRACT FOR PLATFORM HIGH BAY CV -6 C -3 FC -2 CHILLED WTR 7 GPM 4.7 THREAD BRASS 1/2" ELECT 2 2 BELIMO B213- LF24 -SR US FURNISHED ON ATS CONTRACT FOR RF ROOM 510 STEAM TRAP SCHEDULE TAG SERVES QUANTITY LOCATION PRESSURE OPERATING DESIGN LOAD ( # /HR) COLD START -UP LOAD ( # /HR) SIZE BASIS OF DESIGN REMARKS INLET (PSIG) OUTLET (PSIG) MFGR MODEL T -1 AHRB2 2 HIGH BAY 30 15 510 650 1" SARCO F7-30 FLOAT & THERMOSTATIC . T -2 AHRB2 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -3 AHRD3 2 HIGH BAY 30 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC T -4 AHRD3 2 HIGH BAY 30 15 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC T -5 AHRD2 2 HIGH BAY 30 15 510 650 1" SARCO F7 -30 FLOAT & THERMOSTATIC T -6 AHRD2 2 HIGH BAY 30 15 100 250 3/4" SARCO FT-30 FLOAT & THERMOSTATIC T -7 T -8 AHRB3 AHRB3 2 2 HIGH BAY HIGH BAY 30 30 15 15 510 650 1" SARCO FT -30 FLOAT & THERMOSTATIC 100 250 3/4" SARCO FT -30 FLOAT & THERMOSTATIC SYM A B C UNIT NO AHRB2 AH R D3 AHRD2 AHRB3 LOCATION ROOF ROOF ROOF ROOF TYPE CENT CENT CENT CENT TOTAL CFM 16,500 16,500 16,500 16,500 MINIMUM OA CFM 1,650 1,650 1,650 , 1,650 SUPPLY FAN SECTION TSP ESP RPM (IN. WG) (IN. WG) 609 2.19 1.00 609 609 609 2.19 2.19 2.19 1.00 1.00 1.00 QTY MOTOR HP 15 15 15 15 VOLTS 460 460 460 460 ROOFTOP AIR HANDLING UNIT SCHEDULE PH CFM 16,500 16,500 16,500 16,500 STEAM PRESS 30 PSIG 30 PSIG 30 PSIG 30 PSIG HEATING COIL LBS/ EDB HR ' F 1017 40.0 1017 1017 1017 40.0 40.0 40.0 LDB 'F 92.9 92.9 92.9 92.9 TOTAL MBH 945.93 945.93 945.93 945.93 FILTERS 8 -16 "X25" 2 -20 "X25" 8 -16 "X25" 2 -20 "X25" 8--16 "X25" 2 -20 "X25" 8 -16 "X25" 2 -20 "X25" EQUIPMENT WEIGHT (LDS) 3,986.40 3,986.40 3,986.40 3,986.40 FAN SCHEDULE UNIT NO. EFRE2 AREA SERVED WELD SHOP LOCATION HIGHBAY CFM 30,000 ESP IN WG 1 OV FPM _ 2338 BHP RPM FAN MOTOR HP VOLTS PH 12.63 820 15 460 3 UNIT WGT 1350 FAN TYPE ROOF WHEEL TYPE PROP BASES OF DESIGN COOK 48 -SUB REMARKS UPBLAST BELT DRIVE WITH CURB AND VFD ISSUE FOR PERMIT /BID INSTALL AHRB3 ADD 2 FAN /COIL UNITS REVISION 534907 -03 55776005 56739200 BY COFFMAN HARR HARR APPROVED RWS DATE 01.12.05 08/22/06 12/10/07 SYM REVISION BY APPROVED DATE CURB WEIGHT (LBS) 384.30 384.30 384.30 384.30 L IN. 138.25 138.25 138.25 138.25 UNIT DIMENSIONS W IN. 97.00 97700 97.00 97.00 UNIT NO. AREA SERVED FC--2 OFFICE FC- 1 OFFICE LOCATION C -3 C -3 CHILLED WATER FAN /COIL UNIT SCHEDULE CFM 550 1200 ESP IN WG OV FPM FAN MOTOR BHP RPM 1/2 HP 1/2 VOLTS 1/2 PH 1/2 UNIT WGT 96.3 MANUFACTURER TRANE FIRST CO. HEATING & AIR MODEL BCHC018A1 36SHW REMARKS FURN. BY SHINN MECH ON OMEGA CONTRACT FOR PLATFORM FURN. BY EMERALD AIR ON ATS CONTRACT FOR RF ROOM H IN. APPROVED BY 63.50 63.50 63.50 63.50 DEPT. ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DOWN DISCHARGE AIR DUCT SIZE 31 -1/8" X 31 -1/4" 31 -1/8" X 31 -1/4" 31 -1/8" X 31 -1/4" 31 -1/8" X 31 -1/4" Mt Yoc;7e DATE DRAWN NFH CHECKED ILI ENGINEER IU CHECKED APPROVED APPROVED SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical it Electrical tf r ' Gas Piping City of Tukwila BUILDING DIVISION J DATE 01.12.05 01.12.05 01 12.05 SUBTITLE TITLE REMARKS OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CUR3 OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB OFCI --- WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB OFCI - WITH MIXING BOX, FILTERS, FACE & BYPASS DAMPERS, HORIZONTAL STEAM COIL, FAN, AND CURB SCHEDULES REVIEWED 7OR CODE COMPUANCE APPRO' wr MAP /it BUILDING 9 -99 Of Tukwii5 - BUI DIVISION_ LEG .. .Y -, CITY Ur ■ FEB 2 b ZUUB PERMIT CENTER DEV. CENTER, WA \ERAL By Dat 3 -// 7e REFEREE SHEET JOB NO. J DWG NO. \OT FILE C Permit No. 06 .. 090 Mar review approval is subject to errors and omissions. Approve, of construction documents does not authorize the violation of any adopted code or ordinance. Remipl of approv %ld Co _. d ; • is acknowIcrtad: City of Tuhvila BUILDING DriiISTiN CURRENT EVISION 56739200 CE DRAWI REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division NOT Revisions will require a new plan submittal and may include additional plan review fees \STRUCTIO \ \OTES FURNISH & INSTALL FC -2 W/ CV -6. Dcqe M2 SYMBOL 534907 -03 -S 9-99--M2 GS DATE 12/10/07 COMP NO. 30 "0 PRES. RELIEF DUCT W /OPPOSED BLADE DAMPER TO OPERATE W /ECONOMIZER SYM A B C D E 30 "0 DISCHARGE W/45 CUT & BIRD SCREEN 25" X 30 "0 OSA DUCT W /OPPOSED BLADE DAMPER TO OPERATE W/ECONOMIZEF 30 "0 X 90' ELL W /30" CLR & BIRD SCREEN 30" X 90 DEGREE ELL W /30" CLR .. 0" SUPPLY 24 "0 X 90' ELL W/36" CLR (TYP 4) 36" X 36" R/A FROM PUMP ROOM TO 06" X 38" MITERED ELL CONNECTED TO R/A CONNECTION ON A/C UNIT 36" X 36" OPPOSED BLADE DAMPER CONTROLED BY CMCS TO OPERATE OSA ECONOMIZER CYCLE 24 "0 X 45' ELL W/36" CLR (TIP 4) o I o fl PARTIAL PLA\ SCALE: 1/8"=1'0" VIEW DATE 12/10/07 1M1' M529 MI-M11 O E 1M11 M532 M 1 M11 HBM11 28'— ff 0 gto ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN M. DITTMAR CHECKED ENGINEER T. HANSON CHECKED APPROVED APPROVED DATE 09.09.93 09.09.93 SUBTITLE TITLE A, MECHANICAL MASTER a a OFFICE FAN /COIL UNIT: TRANE MODEL BCHC018A1, 1-1/2 TON, 2" PLEATED THROWAWAY FILTER, 1/2 HP, 115/60/1.1/2" Control Valve with 24 VDC operator, 0 -10 VDC proportional, spring- return; Belimo B210—LF24—SR US DIFFUSERS: TITUS 6" MCD, 8 "X8" NECK. RF— SHIELDED ROOM FAN /COIL UNIT: FIRST CO. HEATING & AIR MODEL 36SHW. CONSTRUCTION NOTES: INSTALL FAN /COIL UNIT ON ROOF OF NEW .ROOM. SEE DETAIL ON M510. INSTALL TWO DIFFUSERS APPROX WHERE SHOWN. INSTALL INSULATED SUPPLY DUCT TO TWO DIFFUSERS. INSTALL SECOND FAN /COIL UNIT FOR RF— SHIELDED ROOM. STRUCTURE LAB UPGRADES MODIFY HVAC SYSTEM RCS MODEL SHOP MACHINE REVISION J#170024 -04 BY KGP KGP HARRAH APPROVED DATE 06.30.99 SYM REVISION BY F ADD 2ND FAN /COIL FOR RF—SHIELDED ROOM 56739203 HARR DIGITAL RADIOGRAPHRY LAB 11073700 LM THOMAS NEW ROOM COL. C/3 -4 56739203 HARR RWS 05/30/07 APPROVED RWS FIRST FLOOR PARTIAL HVAC PLAN 9 -99 MODEL SHOP — PHASE 1 AND 2 BUILDING 9 -99.1 COL. A —C/1 -4 GENERAL NOTES: NEDERMAN 7FT FUME EXTRACTOR WITH 14FT EXTENSION ARM AND NEDERMAN N24 FAN WITH 1 HP 4: 1.9 OTi r 150 © " - A REVIEWED FOR - CODE COMPLIANCE MAR f 20 A City iF il!'kwil: BN PERMIT CENTER D.0 CITY tar s UnY�'ii 'j FEB 2 6 2008 KEY PLAN CURRENT REVISION 56739203 SHEET JOB NO. DWG NO. SCALE: NONE SYMBOL 1M11 130240 -00 9- 99 -1M11 COMP NO. DATE 12/10/07 SYM A B C C.1 STRUCTURE LAB UPGRADES DIGITAL RADIOGRAPHRY LAB DIGITAL RADIOGRAPHRY LAB AS RUILD b REVISION 9-99 MODEL SHOP - PHASE 1 AND 2 4100015-01 11073700 11073700 RFI 142 4110737-00 BY KGP DLR GROUP LM THOMAS LM THOMAS BOLLIG W1 MEG. AREA APPROVED KP DATE 06.30.99 07.31.01 05/14/03 9/03 SYM D E RF SHIELD RM & VESTIBULE REVISION PARTIAL PLA SCALE: 1/8"=1'0" 56739203 BY HARR APPROVED RWS VIEW DATE 05/25/07 1 1 1M60 M536 FILTER STATION DETAIL ( ( I I P a r A El A e e 2" CWR 2" CWS 3/4" 3/4 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DATE 09.09.93 SUBTITLE TITLE Ni N 0.9 SEE M1M60 FOR CONT. —3" GCWS/GCWR EQUIPMENT COOLING 0 M536 FIELD VERIFY CONNECTION FIRST FLOOR PARTIAL HVAC PIPING PLAN GENERAL NOTES: 1. CHWS/R & CD PIPING: TYPE L COPPER, ASTM B88, RIDGID PROPRESS OR SWEAT SOLDER FITTINGS. 2. INSULATION: 3/4" FIBERGLASS WITH VAPOR—BARRIER JACKET, KRAFT REINFORCED FOIL VAPOR BARRIER WITH SELF—SEALING ADHESIVE JOINTS. CONSTRUCTIO ROUTE 1-1/2" COPPER CHWS & CHWR PIPES ON WALL. TERMINATE APPROX. 8 FEET NORTH OF COLUMN C-4 AND 5 FEET ABOVE FLOOR WITH BALL VALVES. °VEGA RIGGERS: LABEL NEW 1-1/2" PIPES: "CHWS DRAIN!" AND "CHWR — DRAIN". (FAN/COIL LOCATION CHANGED, SO THESE LINES WON'T BE USED AS SUPPLY/RETURN.) L ' C N co VV m E1 : : , ,,, ; ,.:_ 1 1 APPROVEO City Of Tukwl:: B:LD CITY km- CURRENT REVISION SHEET 56739203 LEAVE NEW REV D CHW DROPS; LABEL AS "DRAIN" 56739203 HARR 12/06/07 APPROVED BY DEPT. DATE DRAWN M. DITTMAR CHECKED ENGINEER T. HANSON CHECKED APPROVED APPROVED 09.09.93 MECHANICAL MASTER BUILDING 9-99.1 COL. A-C/1-4 LEGEND: GCWS/R GLYCOL COOLING WATER SUPPLY/RETURN CWS/R COOLING TOWER WATER SUPPLY/RETURN D.0 JOB NO. DWG NO. \ NOTES: FEB 2 6 2008 KEY PLAN SCALE: NONE PERMIT CENTER SYMBOL 1 M60 11073700 9-99.1-1M60 DATE COMP NO. 12/06/07 SYM A B C D IN RF- SHIELDED ROOM n 1-1/2" CHWS /R FAN /COIL UNITS 1M61 M510 3" CWR UP TO M1 "CWS UP T 1 "0 BYPAS RUN PIPE HIG ON THIS WALL APPROX. 8' A E 1M61 M53 HOSE CONNECTION DETAIL -TYP OF 3 GENERAL NOTES: CHWS /R & CD PIPING: TYPE L COPPER, ASTM B88, RIDGID PROPRESS OR SWEAT SOLDER FITTINGS. INSULATION: 3/4" FIBERGLASS WITH VAPOR- BARRIER JACKET, KRAFT REINFORCED FOIL VAPOR BARRIER WITH SELF - SEALING ADHESIVE JOINTS. THERMOSTAT: HONEYWELL TH8110, INSTALLED FOR COOLING CONTROL. CONSTRUCTION NOTES: 'K I N Co\ JU CTI O ROUTING OF 2" CHWS /R NOW SHOWN ON LID OF ROOM, AS ACTUALLY INSTALLED. EXTEND 1" BRANCHES TO NEW OFFICE FAN /COIL UNIT. INSTALL (2) 1" BRASS ISOLATION BALL VALVES, ONE WYE- PATTERN STRAINER, AND ONE BELIMO B212 LF24-SR US CHILLED WATER CONTROL VALVE. INSTALL THERMOSTAT IN SUITABLE LOCATION IN NEW OFFICE AREA. CONNECT TO FAN /COIL UNIT CONTROL VALVE. SELECT STAT FOR COOLING SERVICE. ROUTE 1" CONDENSATE DRAIN TO EXISTING FLOOR DRAIN AT FIRE RISER. EXTEND 1" BRANCHES TO NEW RF- SHIELDED ROOM FAN /COIL UNIT. INSTALL (2) 1" BRASS ISOLATION BALL VALVES, ONE WYE- PATTERN STRAINER, AND ONE BELIMO B212 LF24 -SR US CHILLED WATER CONTROL VALVE. INSTALL THERMOSTAT IN SUITABLE LOCATION IN RF- SHIELDED ROOM. CONNECT TO FAN /COIL UNIT CONTROL VALVE. CWS /R STRUCTURE LAB UPGRADES MODIFY HVAC SYSTEM RELOCATE EQUIPMENT TO IASL INSTALL BYPASS LOOP 9 -99 MODEL SHOP PHASE 1 M506 REVISION PACO /1_4012 CENT. PUMP RATED O 475 GPM @125 FT WITH A 25 HP, 460 V MOTOR 757003 -00 765412 -00 100015 -01 2 1/2" CLWS /R UP TO M1M61 BY KGP KGP KGP KGP DLR GROUP APPROVED EJC EJC RP DATE SYM 06/30/99 F 03/09/95 G 11/97/96 H 07/31/01 UP TO ABOVE CRANE RAIL i REVISION x DIGITAL RADIOGRAPHRY LAB AS BUILD CHW TO VESTIBULE /OFFICE & RF- SHIELDED RMS REROUTE NEW CHW FOR RELOCATED FAN /COIL A Y x 110737 -00 110737 -00 56739203 56739203 BM6 1 M61,HBM61 1" TA HYDRONICS CIRCUIT SETTER. PARTIAL PLA SCALE: 1 /8 " =1'0" BY LM THOMAS BOLLIG HARR HARR APPROVED RWS VIEW 1M6 0 PEN AREA 13C1 a 4' 4 2" CWS 2" CWR 3/4" CWS /CWR 05( 1 M61 M533 OPEN AREA MeV VAULT 1/2" BYPASS 1501 0 VESTIBULE PROVIDE FLEX COUPLINGS(VICTAULIC STYLE 77) BETWEEN BUILDING CONSTRUCTION TYPES FOR EARTHQUAKE PROTECTION_ 3" GCWS /GCWR AIR SEPERATOR 1M61 M528 P2 PI \iCi� �1CiJ DUAL PACKAGE PUMP CHEM FEEDER ���) DRY COOLER EXPANSION TANK 9 CODE COM l AppR , OWOfTu l P It LEGEND: GCWS /R GLYCOL COOLING WATER SUPPLY /RETURN CWS /R COOLING TOWER WATER SUPPLY /RETURN CHWS /R CHILLED WATER SUPPLY /RETURN CD CONDENSATE DRAIN EVAPCO #ATW -13C FLUID COOLER RATED TO 5300 MBH W2 DEGREE WB WITH A 20 DEGREE TEMP RISE CITY Or % uhvvci 4, FEB 2 6 ZOOS KEY P A\ SCALE: NONE PERMIT CENTER 9/03 05/29/07 12/10/07 C ENCINEER /09/ DATE 12/10/07 COMP NO. 2 2 1/2" CWR DN TO 1M61 1/ " CWS DN TO 1M61 SYM A B REVISION CHW TO ENTRY ROOM AND RF- SHIELDED ROOM 56739203 AS -BUILT CHW ROUTE PER RA-01; ADD AAV'S 56739203 BY HARR HARR CLIMATE MASTER #V --360 HEAT PUMP RATED TO 240 MBH SENSIBLE W /60 GPM OF CONDENSER WATER. APPROVED RWS 3" CWS UP /DN TO HBM61/1M61 3" CWR UP /DN TO HBM61/1M61 DATE 05/29/07 12/10/07 SYM REVISION ROOF P EA\ SCALE: 1/8 "= 1'--0" BY APPROVED DATE Mo4Va ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN LM THOMAS CHECKED ENGINEER LM THOMAS CHECKED APPROVED APPROVED DATE 06/10/02 06/10/02 SUBTITLE TITLE MECHANICAL MASTER MEZZANINE PARTIAL PLAN HVAC PIPING BUILDING 9-099 Cot . C -E/1 -4 C� r; f \ o LEGEND: R - .. CITY ur i Ut•�+�:� a FEB 2 6 2008 PERMIT CENTER DEV. CENTER, WA SHEET DWG NO. GENERAL NOTES: INSTALL AUTOMATIC AIR VENT AT HIGHEST POINTS OF NEW 2" CHWS & CHWR PIPES. < EY P SCALE: NONE CURRENT REVISION 5673920.3 JOB NO. 110737 -00 AN SYMBOL MIM6I B 9- 099 -M1 M61 DATE 12/10/07 COMP NO.