Permit M08-059 - WESTFIELD SOUTHCENTER MALL - JOEY'S GRILL
OEY'S GRILL 758 SOUTHCENTER MALL M08 -059 Parcel No.: 6364200010 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: GREG DIMMITT Address: 19430 68 AV S , KENT WA Value of Mechanical: $82,340.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 CitAf Tukwila 758 SOUTHCENTER MALL TUKW JOEY'S GRILL 758 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA Contractor: Name: KEY MECH CO OF WASHINGTON Address: 19430 68 AV S, SUITE B , KENT WA Contractor License No: KEYMEW *240NZ DESCRIPTION OF WORK: INSTALL REFRIGERATION SYSTEMS FOR RESTAURANT Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 872 -7392 Phone: 253- 872 -7392 Expiration Date: 04/01/2009 M08 -059 03/07/2008 09/03/2008 Fees Collected: $1,041.88 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 9 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 0 M08 -059 Printed: 03 -07 -2008 Permit Center Authorized Signature: governing this work will be complied doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us • Permit Number: M08 -059 Issue Date: 03/07/2008 Permit Expires On: 09/03/2008 Date: O * 1 I hereby certify that I have read and e . ed this permit and know the same to be true and correct. All provisions of law and ordinances th whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or e perfor nance of work J am authorized to sign and obtain this mechanical permit. Signature: ' - Date: 3-5 Print Name: G 9 /Pvt. S ` (l' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -059 Printed: 03 -07 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Permit Number: M08 -059 Address: 758 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 03/03/2008 Tenant: JOEY'S GRILL Issue Date: 03/07/2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDTITONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinlder heads. (IFC 901.4)(Extend sprinlder protection to walk -in coolers /freezers.) 12: Sprinlders shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 13: All new sprinkler systems and all modifications to existing sprinlder systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinlder systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and/or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of doc: Cond -10/06 M08 -059 Printed: 03 -07 -2008 such condition or violation. doc: Cond -10/06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** M08 -059 Printed: 03 -07 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Gt doc: Cond - 10/06 /144 MA l Date: 3 - 7-0g M08 -059 Printed: 03 -07 -2008 Site Address: Tenant Name: Property Owners Name: Mailing Address: CITY OF TUKWILA di Community Development partment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE'•I.00ATION 758 Asokiti G ,I AL. AAI city t t I CONTACT. PERSON < - who do; w e contact when your permit is.reaidyr tie issued. l - � r R53 5.3 — S F)! 7 Y ∎Q Name: [, � � tun LY11 � Day Telephone: Mailing Address: T q4-30 6.' a -e S Yt E -Mail Address: �/1,fm i f � 0 1 t= yvt I O v • •I • TRACTQR INFORIIATNf: tt �• Company Name: Mailing Address: Company Name: Mailing Address: Company Name: Mailing Address: / 44 '— 4 R ` iu.p Contact Person: (7 heq L) C I £'V) 1 /l i t ' 4 V E -Mail Address: Contractor Registration Number: /t y f1E W ,'� ,() A) Z Q:Wpplications\Forms- Applications On Line 3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh King Co Assessor's Tax No.: 6,3C, 400 _001 CD Suite Number: Floor: New Tenant: D.... Yes V3 State Zip CO et City State i3945 ScR Fax Numb er p 5 3-87.2 -7 398 ..No tOO, ego 3c State Zip City rr�� Day Telephone: t�?55.3- 67.? - 739? Fax Number: oZ52, - • c? - 7 3Q, Expiration Date: -, . , »$n'p a rchiteNc of _ • State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: L. 1' ENGINEER OF RECORD — All plans: must be wet stamped by Engineer• of Recor State Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 of 2 i Valuation of Project (contractor's bid price): $ y 3ito Scope of Work (please provide detailed information): Use: Residential: New .... [] Replacement .... [] Commercial: New ... Replacement .... [] Fuel Type: Electric Indicate type of mechanical work being installed and the quantity below: Unit Type: Furnace <100K BTU Furnace >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig/Cooling System Air Handling Unit <10,000 CFM Qty Unit Type: Air Handling Unit >10,000 CFM Evaporator Cooler Ventilation Fan Connected to Single Duct Ventilation System Hood and Duct Incinerator - Domestic Incinerator — Comm /Ind Qty Unit Type: Fire Damper Diffuser Thermostat Wood /Gas Stove Water Heater Emergency Generator Other Mechanical Equipment Qty Boiler /Compressor: 0 -3 HP /100,000 BTU 3 -15 HP /500,000 BTU 15 -30 HP /1,000,000 BTU 30 -50 HP /1,750,000 BTU 50+ HP /1,750,000 BTU Qty PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW OR AUORI ED AGENT: Signature: Date Application Accepted: Gas ....0 Print Name: G Mailing Address: c Date Application Expires: D`I I (74o`1) Q.Wpplications \Forma - Applications On Line \3 -2006 - Mechanical Permit Application. doc Revised. 4-2006 bh Other: Date: 3 — 3 0 8 Day Telephone: .2 S3 537 7 9.7 City CL92 ?go 3.? State Zip Staff Initials: Page 2 of 2 i Receipt No.: R08 - 00590 Initials: JEM User ID: 1165 ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -059 Address: 758 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/03/2008 Applicant: JOEY'S GRILL Issue Date: Payee: KEY MECHANICAL CO. OF WASHINGTON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2024 1,041.88 Account Code Current Pmts 000.322.102.00.0 833.50 000/345.830 208.38 Total: $1,041.88 Payment Amount: $1,041.88 Payment Date: 03/03/2008 09:57 AM Balance: $0.00 9322 03/03 9710 TOTAL 104188 doc: Receiot -06 Printed: 03 -03 -2008 Projt.. C -. 0 6r , l I . Type of Inspection: -tn/'4 J Address: 7"i ili4 // Date Called: Special Instructions: • Date Wanted: 3' a.r�l. Requester: Phone No: 2-O '/ --663 v 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 X Approved per applicable codes. COMMENTS: corele cU Inspector: Corrections required prior to approval. 'Date: ,e 244s El $6 ' .0 ' EINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 'Receipt No.: 'Date: COMMENT' / 4-..). 4 4 • �t 7..-5-7/ du) 7 /rte / -/ .1/I / t1 /2 -9,6,9 .9 /{ / -,lareive--/ Address: 75 (S - /14 41/ ? /Nir3 iTA /%-r• she,'- /GD• -si', ac/ ,./_ gyve:/ i "./, eee.t,-/ ,'ype L4.6•/5 — ed -,• v Special Instructions: "1_,) 74/T95 A.,,y4 s f/ i /a3 4 4 0 8 1 0 4 1 0 /00.11 .11 . �n� P.m. Requester: y `;re 17;%.49 /-AloVelo ir w ll e42 Phone No: aa ( -' 3q ) -(63 V 2 /A/1f L.n6 .'/s - 1/ D - new.- 64i(,-,., Projec C(6r1 ) ( Type of Inspection: F '1/4r Address: 75 (S - /14 Date Called: �, Special Instructions: Date Wanted: c� — ) a. oG....- �n� P.m. Requester: Phone No: aa ( -' 3q ) -(63 7 ?vi e-6. 0 5'9 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PRMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 0 Approved per applicable codes. El Corrections required prior to approval. Dat u.00 REINSPECTION EE REQU RED. Prior to inspection, fee must, be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Projec / / Type of I { 6 n: A _ w / Address: 7.5 .5'e6 /liefer N4 /14 Date Called: 4 Special Instructions: Datet ec}� J // / p.m. Requester: et ycy_663 7 INSPECTION RECORD etain a copy with permit - RSPECTION NO. e -659 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367.0 Approved per applicable codes. Corrections required prior to approval. F COMMENTS: 1 piii t/ - I / r* vet 7 REINSPECTION FEE EQUIRED. Prior o inspection. fee must be id at 6300 Southcenter Blvd., Suite 10V Call the schedule reinspection. k ceipt No.: Dat z y_e) Date: z ACTIVITY NUMBER: M08 - 059 DATE: 03 - - PROJECT NAME: JOEY'S GRILL. SITE ADDRESS: 758 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t2t !JO) �5 Building Division LB Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP 511 AW G 3 . y11 Fire Prevention Structural Incomplete n Planning Division n Permit Coordinator n DUE DATE: 03-04-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DATE: DUE DATE: 04-01-08 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License KEYMEW *240NZ Licensee Name KEY MECH CO OF WASHINGTON Licensee Type CONSTRUCTION CONTRACTOR UBI 600196154 Ind. Ins. Account Id Business Type CORPORATION Address 1 19430 68TH AVE S STE B Address 2 City KENT County KING State WA Zip 98032 Phone 2538727392 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/9/1976 Expiration Date 4/1/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License Business Owner Information Name Role Effective Date Expiration Date HEISLER, ROBERT L 01/01/1980 LEONARD, FRANK W 01/01/1980 SANDAHL, LEE F 01/01/1980 Look Up a Contractor, Electrl in or Plumber License Detail Washington State Department of Labor and Industries GeneraUSpecialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date INSURANCE CO OF THE Until Page 1 of 3 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= KEYMEW *240NZ 03/07/2008 ICE MACHINE CONDENSER DENOTES REFRIGERATION CONNECTION 1/2 - - DENOTES REFRIGERATION RISER LOCATION 1/2 DENOTES REFRIGERATION OVERHEAD PIPING ■ COOLER ICE MACHINE CONDENSER 7/8 DISCHARGE 1/2 BEER COOLER 7/8 1/2 7/8 ■ COOLER 7/8 1/2 7/8 • PROTEIN COOLER 7/8 112 5/8 1 FREEZER 1-1/8 1/2 7/8 KITCHEN 7/8 1/2 7/8 ' SLUSHY 1 -3/8 1/2 7/8 1 SLUSHY 1 -3/8 1/2 7/8 ■ BARS 7/8 1/2 5/8 oWINE CASE 7/8 1/2 5/8 SYS # SYS # SYS #: SYS # SYS # SYS #F SYS #; SYS # SYS # SYS #1 R -FRIG RLFR G =RATED SVS SUCTION =RAT ON LIQUID v LEGEND S RISER R „ UNDER GROUND 4" PVC with 2" liquid line suction line (SEE =1REPLACE MECH. DI GS) • SYS #9b J 16.4 OFFICE L 0 SYS #1 F.D PRIVATE PARTY ROOM I L'J SM -134AE SYS #2 RECEPTION AREA G RAT ill �i�ir►�M: riM r: r- r- r- N N I \ I \ I \ I \I \I \ mu • 71■I■ u ■i•i•• i in ■I■ IN BE ■I■ ■ ■I■ No • o\ SYS #6c I — _ - I L_ _J SM - 134AE SYS #3 SYS #6a SCF 1 N r -� N N \I \I \ \I \I \ MUM Man Kam in ■I■I■ F.D /F.S SYS #6d UNDER GROUND 4" PVC with liquid line 8" suction line SYS #9a SYS #6b ELL r�1 L / k_ /1 L___J SM- 090AE SYS #4 1111111111 ■■■r■rrr�r■rrr.�■■ ern■ r■■ rrrrr�rr. .■�r.r■rrrn■rrrr�■�rr■��r�■r�r� E 7 _ 1 SME -13OBE SYS #5a ■I■I■I■I■I■I■I■I ■I■ EN iii MB iii i SYS #6e `1 / I I / I / I SYS #10 y 0 1 FIRST EL ❑❑R TO SECOND EL❑DR RISERS STORAGE CEP RA A E PERMIT REQUIRED FOR: Vecnanical lectrical [Plumbing VGas Piping City of Tukwila BUILDING DIVISION REViS1ONS No changes shall be made to the scone of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan submitt -2I and may include additional plan review fees SEC ❑ND FLOOR TO ROOF RISERS SYS SYS SYS SYS SYS SYS 2 4 8 9 10 Ev Date � - fig REVIEWED 77,;r: CODF COMPLIANCE CE APPFICNCr City of Tukwila £JgDNCD`,NSON MAP 21TE Refrigeration Rack Model WF3— AC— H -9 —A -3 Piar review approval is subject to errors and ofssions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Reim o' approved Fi d Copy r d conditions is ackn C e8•. CITY ur ur.v.:_ MAR 0 3 2008 PERMIT CENTER PIOS-)cl co m al CO mn m ncu I n N co c g n CU C0 v cu CU X U- CU M CO m z F- L7 z I. C4 3 1= z w F- H z I- 0 w z F- oa Y 0 CU z a. d z z a_ T T ... MODEL NO. AIR-COOLED MULTI -CIRCUITED RACK CAPACITY BTUH QTY. OF FANS PHYSICAL DATA STANDARD OPTIONAL APPROX. NET WT. (lbs.) 10' T.D. 15' T.D. L INLET SUCTION REVISED DATE: February 4, 2008 VOLT AMPS SM090 1260 9000 RACK #1 2 53-1/2" 1/2" FN 7/8" OD 115 4.2 230 2.2 70 SM134 1890 13400 20100 3 NOTES: Revised from parallel rack to multi-circuited rack. 7/8" OD 115 PROJECT NAME: Joey's Southcenter 3.3 117 REP: LOCATION: WA CONTACT: BID BY: Abraham CONSULTANT: ITEM / MODEL OF RACK: # / # WF3- AC- H -9-A -3 (460v) CONTACT: SIZE / WEIGHT OF RACK: 168" X 48" X 52" /# 2,245 lbs. COMP PWR VOLT COIL ITEM SYS DESCRIPTION BTU FIX SUC R COMPRESSOR CAP HP WT. PH T.W.R. RLA LRA L1 U L3 QTY COIL FAN DEF PH WT. A Beer Cooler 13.4 +35 +25 22 CS12K6E -TF5 15.1 1.75 90 208/3 19.6 7.5 51.0 3.8 3.8 3.8 1 SM -134AE 6.3 115/1 125 B Walk -In Cooler 13.4 +35 +25 22 CS12K6E -TF5 15.1 1.75 90 208/3 19.6 75 51.0 3.8 3.8 3.8 1 SM -134AE 6.3 115/1 125 C Protein Cooler 9.0 +35 +25 22 CS10K6E -TF5 10.6 1.5 90 208/3 14.3 7.5 51.0 3.8 3.8 3.8 1 SM-090AE 4.2 115/1 75 D Walk -In Freezer 6.5 -10 -20 404a AVA2490ZXT 9.2 3.0 130 208/3 16.6 7.4 65.1 4.8 3.7 4.8 1 SME -065BE 2.2 8.7 208/1 135 E Bar Cooler 7.7 +35 +20 22 RS80C2E -CAV 8.1 1.25 80 208/1 11.1 9.6 46.0 4.8 4.8 1 By MFG. VFY 115/1 5 F Slush Freezer 16.5 +0 404a ZF11K4E -TF5 19.3 3.5 115 208/3 19.8 13.6 88.0 6.8 6.8 6.8 1 By MFG. VFY 115/1 5 G Slush Freezer 16.5 +0 404a ZF11 K4E -TF5 19.3 3.5 115 208/3 19.8 13.6 88.0 6.8 6.8 6.8 1 By MFG. VFY 115/1 5 H Kitchen Refrigerator 14.6 +35 +20 22 CS14K6E -TF5 15.2 2.0 90 208/3 20.7 9.1 55.0 4.6 4.6 4.6 1 By MFG. VFY 115/1 5 J Wine Cabinet 14.0 +35 +20 22 CS14K6E -TF5 15.2 2.0 90 208/3 20.7 9.1 55.0 4.6 4.6 4.6 1 By MFG. VFY 115/1 5 K Hoshizaki I/M #KM2400SR 0 VFY Condenser Circuit 38.9 Condenser Fan .75 208/1 4.8 2.4 2.4 Condenser Fan .75 208/1 4.8 2.4 2-4 Condenser Fan .75 208/1 4.8 2.4 2.4 Transformer Weight 340 I Rack Weight 1015 Total Rack Weight 2245 201.1 Line Amps: 461 47.5 46.2 485 Conn: 47.5 Min: 49.2 Max: 60.0 460v. 30 60cy. W/ transformer MODEL NO. CFM CAPACITY BTUH QTY. OF FANS PHYSICAL DATA STANDARD OPTIONAL APPROX. NET WT. (lbs.) 10' T.D. 15' T.D. L INLET SUCTION VOLT AMPS VOLT AMPS SM090 1260 9000 13500 2 53-1/2" 1/2" FN 7/8" OD 115 4.2 230 2.2 70 SM134 1890 13400 20100 3 75-1/2" 1/2" FN 7/8" OD 115 6.3 230 3.3 117 MODEL NO. CFM CAPACITY - BTU PHYSICAL DATA FAN MOTORS DEFROST HEATERS APPROX. NET WT. (lbs.) 10' T.D. 12' T.D. L M INLET SUCTION ELECTRICAL AMPS ELECTRICAL AMPS SME0651 1260 6500 7800 53 -1/2" 22" 1/2" FN 7/8" OD 208 -1-60 2.2 208 -1 -60 8.7 77 COIL DRAIN LINE DETAIL AIR FLOW REFRIGERATION CONT'R TO SEAL PENETRATION 1011101111I1III1I1I 1II (!M'I!IQ►I11111 INSULATED SUCTION UNE & LIQUID UNE COIL COPPER UNION ALL DRAIN UNES REQUIRE A MINIMUM OF 1/2" FALL PER FT. ELECT. HEATER SPIRALED & TAPED ON FREEZER DRAIN BY REFRIG'N CONTRACTOR COPPER DRAIN UNE NOTES: 1. RUN EACH DRAIN SEPARATELY 2. CENTER COIL IN BOX AIR FLOW 0 0 0 0 0 [ TRAP TYPICAL PIPING FOR VERTICAL RISERS REFRIGERATION UNIT REFRIGERATION RACK 0 ROOF OR HIGHER LEVEL REFRIGERATION LINE P -TRAP EVERY 15' TYPICAL WIRING DIAGRAM FOR TIME CLOCK © FIXTURE 110v. N DRAIN HEATER r --- FOR SYSTEMS- F & G BROKEN LINES INDICATE FIELD WIRING (BY FIELD ELECTRICIAN) BY FIELD CONTRACTOR TYPICAL WIRING DIAGRAM FOR OFF CYCLE AIR DEFROST TIME CLOCK L1 115v. MOUNTED AND PRE -WIRED TO SINGLE POINT CONNECTION WITH EVAP FANS. OFF CYCLE AIR DEFROST TIME CLOCK T -STAT FOR SYSTEMS: A,B,C & E COIL SPECIFICATIONS 1 /2" 4 -34" O M* UNIT COOLER MODEL SM /SME ELECTRICAL CONN. REFRIGERANT CONN. DRAIN 3/4 FPT 4 -3/4" SPECIFICATION DATA 7/16" ml 28- 13/16" 28 -5/8" 7/16" WIRING DIAGRAM n MO m REFRIGERATION SCHEDULE Warning: Refriger installer m ust hoi‘fe nitrogen flcwie - tig tiro re: i..i h III pips duri li wr Id Fctory will riot pay for array damage in the salenvid yr e )cpar>tsivr - I Neathaf cauis d IDy scales ii tl - >ts� pipe- GENERAL NOTES GENERAL 1. CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND COORDINATE WITH OMNI TEMP REFRIGERATION. 2. REFER TO ALL NOTES ON THIS PLAN. ROUTING OF REFRIGERATION TUBING IS FURNISHED AS A GUIDE. IT WILL BE NECESSARY TO COPE WITH CONSTRUCTION CONDITIONS. 3. ALL. CORED HOLES REQUIRED ON JOB ARE TO BE PROVIDED BY GENERAL CONTRACTOR. 4. ALL CORED HOLES SHALL BE FIREPROOFED AS REQUIRED BY LOCAL CODES BY GENERAL CONTRACTOR. 5. MINIMUM OF 30" CLEARANCE FOR ACCESSIBIUTY AROUND COMPRESSOR RACK NEEDED FOR SERVICEABIUTY. MINIMUM OF 36" CLEARANCE IN FRONT OF ELECTRICAL PANEL. 6. AFTER INSTALLATION OF REFRIGERATION ONES, GENERAL CONTRACTOR SHALL BACKFILL THE PITCH POCKET AS REQUIRED. REFRIGERATION NOTE ALL COILS SUPPLIED WITH EXPANSION VALVES, THERMOSTATS AND SOLENOID VALVES MOUNTED AND PRE -WIRED IN EACH COIL SUPPLIED BY OMNI TEMP REFRIGERATION. ALL COPPER TUBING TO BE REFRIGERANT GRADE TYPE "L ". JOINTS FOR ALL HARD COPPER TUBING SHALL BE SWEAT TYPE FITTINGS (MECHANICAL BEND IS NOT ACCEPTABLE). SUCTION ONES TO BE INSULATED WITH 1/2" WALL PLASTIC INSULATION FOR COOLERS AND 3/4 WALL INSULATION FOR FREEZERS. 2. ALL SUCTION LINES WITH 15FT. OR MORE VERTICAL RISE, ARE TO BE TRAPPED FOR PROPER OIL RETURN. 3. FOR STEEL TO COPPER CONNECTIONS, USE SILVER SOLDER. FOR COPPER TO COPPER CONNECTIONS, USE SIL -FOS. (SOFT SOLDER SHALL NOT BE USED FOR REFRIGERANT PIPING). 4. ALL PIPING SHALL BE PRESSURE TESTED WITH NITROGEN AT 300 PSI. 5. ALL COMPLETED REFRIGERATION SYSTEMS MUST BE EVACUATED TO 500 MICRONS OR LESS WITH VACUUM PUMP. 6. FURNISH AND INSTALL A 6 WATT PER 1FT. 230V, HEATER TAPE ON WAUC -IN FREEZER DRAINS. 7. ALL COILS SUPPUED BY OTHERS MUST HAVE EXPANSION VALVES COMPATIBLE WTH THE REFRIGERANT USED ON EACH SYSTEM. 8. ALL FIELD PIPING SUPPORTS ARE TO HAVE PLASTIC INSULATION BETWEEN CLAMPS AND PIPING, NO COPPER TO STEEL CONTACT PERMITTED. 9. OMNI TEMP NOT RESPONSIBLE FOR FIELD WRING. EACH SYSTEM AND EVAPORATOR IS SHIPPED UNDER NITROGEN PRESSURE. SAFETY CAUTION: USE CAUTION AND EXERCISE SAFETY AT ALL TIMES WHEN PREPARING FOR FINAL HOOKUP. ELECTRICAL 1. ELECTRICAL CONTRACTOR (DIVISION 15) IS TO PROVIDE POWER FOR REFRIGERATION RACK AND ALL COILS. ELECTRICAL CONNECTION REQUIRED FOR RACK CONTROL PANEL AND DEFROST SYSTEMS AS PER THE WIRING DIAGRAM. 2 ELECTRICAL CONTRACTOR (DIVISION 16) TO PROVIDE MULTI -COLOR CODED SERVICE FROM THE TIMECLOCKS AT THE REFRIGERATION PACKAGE TO BLOWER COILS IN THE FIXTURE FOR AUTOMATIC DEFROST, UNLESS THE BLUEPRINT INDICATES OTHERWISE. 3. ALL ELECTRICAL WIRES AND INSTALLATIONS SHALL BE IN ACCORDANCE WITH THE WRING DIAGRAM AND LOCAL CODES. 4. ELECTRICAL CONTRACTOR (DIVISION 16) TO PROVIDE ANY DISCONNECT SWITCH NEEDED BY LOCAL CODES. 5. FOR F.W.I. ITEMS, THERMOSTAT AND SOLENOID WIRED TO COIL BY FIELD ELECTRICIAN. PLUMBING 1. PLUMBING CONTRACTOR (DIVISION 15) TO PROVIDE HARD ACR OR TYPE "L' COPPER CONDENSATE DRAIN UNES FOR WALK -IN FREEZERS AND REFRIGERATORS. PITCH TO BE MINIMUM OF 1/2" PER FOOT OF RUN IN FREEZERS. DRAIN ONES MUST BE INSULATED TO PREVENT FREEING. DRAIN UNES MUST BE TRAPPED TO AVOID ENTRANCE OF WARM AIR. PROVIDE INDIVIDUAL DRAIN LINES FOR EACH EVAPORATOR. UNLESS OTHERWISE INDICATED. 2. PLUMBING CONTRACTOR (DIVISION 15) TO VERIFY THE METHOD USED AND LOCATION FOR FIXTURE DRAINS. WHEN REQUIRED, INSTALLATION OF DRAIN UNES IN WALL SHOULD BE DONE BEFORE THE WALL IS CLOSED OFF. MAIN POWER POINT OF CONNECTION BY ELECT. CONTRACTOR L1 -- L2 L3 --- III TRANSFORMER 460v. TO 208v. • • SYSTEM BEER COOLER H.P.: 1.75 RLA: 7.5 LRA: 51.0 Lt re C.C.H. T/C ® COIL TTT P.S. SYSTEM WALK-IN COOLER HP4 1.75 RLA: 7.5 LRA: 51.0 T/C I COIL C.C.H TTT P.S. SYSTEM PROTEIN COOLER 1.Pa 1.5 RLA: 7.5 LRA: 51.0 T/C 0 COIL C.C.H. TTT P.S. WALK-IN FREEZER H.P._ 3.0 RLA: 7.4 LRA: 65.1 C.C.H. TTT P.S. RELAY DRAIN HEATER TIME CLOCK 1 -BROWN r ----• • - 3 -BLUE 2 N I X- YELLOW X 4 I 4-RED N -BLACK O - • RC SOLENOID ?i BROKEN UNES INDICATE FIELD WRING BY ELECTRICAL CONTRACTOR BAR COOLER H.P.: 1.25 RLA: 9.6 LRA: 46.0 C.C.H. T/C ® COIL • • •5 LIQUID UNE 0 SOLENOID REFRIGERATION CONTRACTOR P S. TO SET TIME CLOCK FOR INITIAL 15 MINUTE CYCLE 0 1:00 AM SLUSH FREEZER H.P.: 3.5 RLA: 13.6 LRA: 88.0 T/C TO 9IP LOOSE G.G.H. T DPS 111S01ARLE STAT a SLUSH FREEZER H.P.: 3.5 RLA: 13.6 LRA: 88.0 T/C TO SHIP LOOSE C.C.H. T - 0 DPS DISCHARGE STAT KITCHEN REFRIGERATOR H.P.: 2.0 RLA: 9.1 LRA: 55.0 C.C.H. T - T P.S. 3• • •1�l • UQUID UNE 0 SOLENOID REFRIGERATION CONTRACTOR TO SET TIME CLOCK FOR INITIAL -15 MINUTE CYCLE 0 1:00 AM WINE CABINET H.P.: 2.0 RLA: 9.1 LRA: 55.0 C.C.H. P.S. 30 • •1 0 • UQUID UNE 0 SOLENOID REFRIGERATION CONTRACTOR TO SET TIME CLOCK FOR INITIAL 15 MINUTE CYCLE 0 1:00 AM HEATED CABINETS am 150 ea. WS 0.6 ea. T -STAT CONDENSER FAN H.P.: .75 neat 4.8 CONDENSER FAN H.P. _ .75 M'S 4.5 15A 15A FUSE FUSE i TEMPERATURE CONTROL 0 80' 1 TEMPERATURE CONTROL 0 50' CONDENSER FAN H.P.: .75 API 4.8 15A FUSE OMNI TEMP REFRIGERATION RACK LIST® UNION MADE -I MODEL F LISTED 4 cc cc 8" 1' -3" ELECT. PANEL L J " -MAIN DISCONNECT � - ACCESS FOR REFRIG'N. TUBING & ELECT. REVIEWED FOR 1 CODE COMPLIANCE APPROVE L. - '; 210, 1 - i9u STANDARD BOLT DOWN BRACIM (NTi1'I CCAG, N 0 u ELECTRICAL CONTRACTOR TO RUN DIFFERENT COLORED WIRES TO FREEZER COIL & CONNECT, AS SHOWN ON WIRING DIAGRAM. ELECTRICAL SUPPLY BEER COOLER WALK -IN COOLER PROTEIN COOLER WALK-IN FREEZER BAR COOLER SLUSH FREEZER SLUSH FREEZER KITCHEN REFRIGERATOR WINE CABINET HOSHIZAKI I /MI<M2400SR TUBING SEQUENCE 13' -O" CURB 12' -O" RACK PLAN VIEW " 0 /. I' 1 I ELEVATION PITCH POCKET j CITY UI- lu:.uv._ • (M O3ZO08 PERMIT CENTER SECTION VIEW 6" HIGH I ROOF PAD & 18 GA. G.I. METAL COVER TO BE PROVIDED BY OTHERS CURB DETAIL 6" MIN. THIS PLAN IS PRIMARILY A GENERAL ARRANGEMENT OF' EQUIPMENT FOR THE CONVENIENCE OF CONTRACTORS AND IS MADE FROM AVAILABLE INFORMATION. BUT MEASUREMENTS ARE TO BE VERIFIED ON THE JOB. PLUMBING, ELECTRICAL, REFRIGERATION, AND VENT OUTLETS HAVE BEEN LOCATED AS ACCURATELY AS POSSIBLE AND ARE INTENDED TO SUIT EQUIPMENT TO BE SUPPLIED. WE ACCEPT NO RESPONSIBILITY FOR WORK DONE BY SAID CONTRACTORS AND WILL NOT STAND ANY EXPENSE FOR CHANGES MADE NECESSARY BY LOCAL BUILDING CODES, ORDINANCES, STRUCTURAL CONDITIONS, OR BY THE SUBSTITUTION OR CHANGES IN EQUIPMENT SHOWN ON THIS PLAN. THIS DRAWING IS THE PROPERTY OF OMNI TEMP REFRIGERATION. IT IS NOT TO BE REPRODUCED OR DISTRIBUTED, EITHER IN WHOLE OR IN PART. NO. REVISION DATE BY NO. REVISION DATE BY Joey's Southcenter FMK _ : V II////j::•..: Al ‘■ ri \fit -_ �rr� Anir. R tr ,rr g the 'needs of tomorr r ow r. EN maw.- :. %I'MIR . = .:11na r WOE- ! ~ - 'VII .� II J IM WiiiIN IIf MW.■li,_::I/E7 .M/ MI : :3I/// 1111111111111/ '' ' UIMIGI ■L fM IUMINN Irr HWIIIf ■Xt'fhIIII %UWE IMlhIM 'WHIM/ 1 19,1010 1 1:5.•rii rm n e p Refrigeration Division of Omniteam, Inc. 9300 Hail Road, Downey, CA. 90241 Phone: (562) 923 -9660 Fax: (562)862 -7466 E -Mail: Refrigeration @omniteaminc.com California Contractors License #:471945 ratic ri F'I DATE: JOB #: 02 -21 -08 '1203"1 SCALE: Ni on DRAWN BY: HUMBERTO LOPEZ CHECKED: SHEET NUMBER: R1 of 1 P: \Omnicadd \Acad \2008dwgs \JOEY'S SOUTHCENTER 1. DWG