Loading...
HomeMy WebLinkAboutPermit M08-060 - GEGE 12600 INTERURBAN AV S M08-060 Parcel No.: 0004800003 Address: Suite No: Tenant: Name: GE Address: 12600 INTERURBAN AV S , T[JKWILA WA Owner: Name: C/O EPROPERTYTAX INC Address: DEPT #207 , PO BOX 4900 Contact Person: Name: TERRY COURSE Address: 899 WEST MAIN , AUBURN WA Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA Contractor License No: IECS * * *044QL DESCRIPTION OF WORK: NEW 2 -TON GAS /ELECTRIC ROOFTOP UNIT WITH NEW DUCTS AND DIFFUSERS Value of Mechanical: $8,500.00 Type of Fire Protection: Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat /Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Citylif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 12600 INTERURBAN AV S TUKW MECHANICAL PERMIT EQUIPMENT TYPE AND QUANTITY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 * * continued on next page ** M08 -060 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 939 -9495 Phone: 206 939 -9495 Expiration Date: 11/20/2008 M08 -060 03/14/2008 09/10/2008 Fees Collected: $271.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 1 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 3 Thermostat 1 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 03 -14 -2008 Permit Center Authorized Signature: doc: IMC-10/06 S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -060 Issue Date: 03/14/2008 Permit Expires On: 09/10/2008 Date: 3-114-09 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe ance of rk. I am razed to sign and obtain this mechanical permit. Signature: —� Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -060 Printed: 03 -14 -2008 • City of Tukwila Parcel No.: 0004800003 Address: 12600 INTERURBAN AV S TUKW Suite No: Tenant: GE 1: ** *BUILDING DEPARTMENT CONDITIONS * ** Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -060 Status: ISSUED Applied Date: 03/03/2008 Issue Date: 03/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M08 -060 Printed: 03 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: doc: Cond -10/06 S e __ t / 442:1 Date: 3 -/'1--tf: 5r M08 -060 Printed: 03 -14 -2008 Tenant Name: CITY OF TUKWIMP Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup:I/www.ci.tukwila.wa.us Contact Person: E -Mail Address: Contractor Registration Number: Company Name: p et U i J • Vc-r Ark 1 Mailing Address: I c I t A p p ra i V' Or, E -Mail Address: E -Mail Address Q: Applicshimiaorms-Appheabons On Lnev -2006 - Penult Apphmhon.doc Revised 9-2006 bh I Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** 04-06o PEA SITE LOCATION King Co Assessor's Tax No.: C2C 0 ( 17 C.)0 C) 3 0 a Site Address: /2. E7 co Pi 'trick ✓ 2 4 k /4 (1? Sa Suite Number: if 6 Floor: New Tenant: [, Yes ❑..No Property Owners Name: L 1O L" P (O P 17 ti--/ yiq T Air 0_44*- g Mailing Address: r C) 0 lk (50 ( }}f 5 5/ C City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: T Fz \I Co o..c - Day Telephone: 25 3 ' - Q ' S Mailing Address: g 1 C, t . . - ) Z 54 ni 4,1t / 4 t . . t i c tr I n L./A- C( row ) city State Zip E -Mail Address: I' S f2 /1- j{L f 1.e.s..kc. W. C—I ( WI S it 1. Cc...-- Fax Number: 29;3 - e/ 3 'I — e/ L 6o GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Mailing Address: stv SeG -(._ City Day Telephone: Fax Number: Expiration Date: State State ZiP ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record 1.4J A-. qv i t4 City Contact Person: Day Telephone: 70G y 33- Tq ct 7 Fax Number: State Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: zip Page 1 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU / / Furnace>100K BTU Evaporator Cooler Diffuser 3 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind MECHANICAL PERMIT INFTION - 206- 431 -3670 • MECHANICAL CONTRACTOR INFORMATION Company Name: S 1 In C Mailing Address: Ir q U In1. At\' Contact Person: I G t i y (ow/ S- E- Mail Address: S c /4 L41-e noe61 CA.N; L41 '&t S 1th Cow Contractor Registration Number: T /'L S U Valuation of Mechanical work (contractor's bid price): $ � ,�51 C O Scope of Work (please provide detailed information): AJe.iJ � , a n CJ- ct,g /efcch,rz- cy Q VD Ll h t' 4- 4 1 f" f 1 l)- e t- J Oc t-C - Lr QY k 9t a A nn -A S Q rIS Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ City State Zip Day Telephone: Vf45 2T3 — Cl3 ` (' ` i q c( 5' Fax Number: 2 — 13 `f - 9 Z 6 o Expiration Date: I f /'2 0 / SK Fuel Type: Electric ❑ Gas.... Other: Indicate type of mechanical work being installed and the quantity below: Q: \Application Fonn - Appbcahons On Lne\3 -2006 - Pemut Apphcanon.doc Revised: 9 -2006 bh Page 4 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets ' Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PIPAPERMIT INFORMATION — 206 - 431.0 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: f E s / f1 C, Mailing Address: `g'l cl L.' -e54- Gi Contact Person: FE jQ s( cocks. $� E -Mail Address: Contractor Registration Number: f C S 1' ' 09 C I q L Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ 4 VU Crm Scope of Work (please provide detailed information): /Z 4 h e.L) /'3 pct ✓ c L 4 s / h.A— t i r o t ' v , e xi 5 i 4+ V► E5 c< s 1-r) 'w o (- to r • Building Use (per Intl Building Code): C c ✓N W'-c r c Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: QMapplicshon,\Fomu- Applications On Unet3 -2006 - Permit Appbcatoadoc Revised: 12006 bb Sewer: City State Zip Day Telephone: .2S - 9 3 9- 9 y et. s Fax Number: 2S1— 13 9- ? Z G Expiration Date: /// `7 0 / h S' Page 5 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Q:wpplic mu\emrorApphcations On tu1e\3 -2006 - Pemnt Apphohon.doc Revised: 9 -2006 bh 2 3 9 2 Date: 9= T `ri Y BUILDING OWNER O AUT IZED AGENT: Signature: ff''��� 9 j �A Print Name: 1M ji.J I5Je 1' Day Telephone: Mailing Address: (Cf '( £) 3 114 r t V\ 4 b c'v N LA a ir ere, ( City State Zip I Date Application Accepted: Date Application Expires: Staff Initials: Page 6 of 6 n_... o•r•erne ne RECEIPT NO: R08 -00605 Initials: JEM User ID: 1165 Payee: IECS, INC. SET TRANSACTIONS: Set Member Amount ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http.• //www. ci. tukwila. wa. us SET RECEIPT SET ID: S000000970 SET NAME: GE EL08 -203 58.00 M08�##�°06,,'0J� 271.25 PG08�'055 92.00 TOTAL: 421.25 ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES Payment Date: 03/03/2008 Total Payment: 421.25 TRANSACTION LIST: Type Method Description Amount Payment Check 41221 421.25 TOTAL: 421.25 Account Code Current Pmts 000.322.101.00.0 58.00 000.322.103.00.0 92.00 000.322.102.00.0 217.00 000/345.830 54.25 TOTAL: 421.25 93(= 3/03 7 TOTAL. 421.25 Project: z Type o Inspecti n: AA V Address: J , `� 1 7 (0 o r / e/1, 1 M '/4v' lTLJ Date Called: €. 5, r Special Instructions: r Date Wanted: _ de , p.m � . Requester: Phone No: _ w - l5 -664S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , st- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. r COMMENTS: L .r.‘51 - 11 - tf 1 /,, I 4_,e,e4 /�PJ .l.�l?" Go -i4�e� l InspectorC Moe -ocoo Date:? ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ,_,_.. - COMMENTS: Type of Inspection: R.r)LA 4 k _ t e tc n *4- c. Address: y 7.60 0 1.,/creru/LA- Al) i Date Called. SuAV `____V �i if-if -!I Je.'SA^: / /e r .' /i- �A�c J �J n c.0sl Cr ; Requester: r� i �t �, J� Phone No: 2-SS v 7,O OD- 4c .70 0- it, Al h ( , 0 . ._� f _ Project : `, � Type of Inspection: R.r)LA 4 k _ t e tc n *4- c. Address: y 7.60 0 1.,/creru/LA- Al) i Date Called. SuAV Special Instructions: Date Wanted 3 -17 -Dr _____ p.m. Requester: Phone No: 2-SS v 7,O OD- 4c INSPECTION RECORD Retain a copy with permit INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 AAo -otov PERMIT NO. (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. Inspec or: dLk, yt Dater . (? — 6 b . ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee rn ist.be . paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: _...__ _ . . �.. Project: Type of Inspection: 1 ` A , I/1 Address: 2 69DD ._ ATeI \ ti... Date Called: 7 L. f. Special Instructions: / Date Wanted: _a m`. 3 -/8 de"— p.m. Requester: Phone No: e-- MO, -o(0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1F 0 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. ./% COMMENTS: I'�tl Z7)t a Pcam%)/l T 44 4 . Iiv■S_c At r .‘k. 6( j-eff Inspectors UA...A Ai( n a (Date: , f ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: 48SD /48SDN Comfort"' 13 Single—Packaged Air Conditioner and Gas Furnace System with R -22 Refrigerant 2 to 5 Nominal Tons (Sizes 024 -060) Single and Three Phase FILE COPY Permit No. —Product-Data Unit 48SD Single- Packaged Rooftop Products with Energy - Saving Features. • Direct Spark Ignition • Low Sound Levels • Up to 81% AFUE • 13 SEER FEATURES/BENEFITS One -piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. Easy Installation Factory- assembled package is a compact, fully self - contained, combination gas heating/electric cooling unit that is pre- wired, pre - piped, and pre- charged for minimum installation expense. These units are available in a variety of standard and optional heat - ing/cooling size combinations with voltage options to meet residen- tial and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high -tech compos- ite basepan eliminates rust problems associated with ground level applications. • 1[1 Of 'Convertible duct conligu ,, at o�I�� D SIGN ukwila Unit is designed for easy sily eithe t o I t o or horizon ap- plications. Each unit is easily converted from horizo to do - flow with the use of the two standard duct covers. A99338 RECEIVED CITY OF TUKYWILA MAP, (1 3 2008 PERMIT CENTER Carrier Ork � \ d tr VE �... MAR 1 1 2008 Efficient operation Iligh- efficiency design with SEERS (Seasonal Energy Efficiency Ratios) of 13.0 and AFUE (Annual Fuel Utilization Efficiency) rat- ings as high as 81 %. Energy - saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are fur- nished with natural gas controls. A low -cost field - installed kit for propane conversion is available for all units. Low NOx units are designed for California installations. These models meet the Californian maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts where a Low NOx rule exists. Durable, dependable components Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. Monoport inshot burners produce precise air -to -gas mixture, which provides for clean and efficient combustion. The large mono- port on the inshot (or injection type) burners seldom, if ever, re- quires cleaning. All gas furnace components are accessible in one compartment. Turbo- tubular' heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for un- proved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air. In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer. Direct -drive multi - speed, PSC (permanent split capacitor) blower motor is standard on all 48SD models. Direct -drive, PSC condenser -fan motors are designed to help re- duce energy consumption and provide for cooling operation down to 40 °F outdoor temperature. Motormaster H low ambient kit is available as a field- installed accessory and does not require a special motor. Corporate thermostats include the Time Guard H anti-short cycle protection circuitry. If an Original Equipment Manufacture (OEM) thermostat is used the Time Guard II field installed anti- short cycle kit must be used. Refrigerant system is designed to provide dependability. Liquid refrigerant strainers are used to promote clean, unrestricted opera- tion. Each unit leaves the factory with a full refrigerant charge. Re- 0 to co frigerant service connections make checking operating pressures easier. Evaporator and condenser coils are computer- designed for opti- mum heat transfer and cooling efficiency. The evaporator coil is fab- ricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The condenser coil is internally mounted on the top tier of the unit. A HOP (Factory - Installed Op- tion) metal louvered grille is available on all models. Copper fin coils and pre- coated fin coils are available from the factory by spe- cial order. These coils are recommended in applications where alu- minum fins are likely to be damaged due to corrosion. They are ideal for seacoast applications. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dB. (See page 3.) Easy to service cabinets provide easy single -panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain provides easy ground level installa- tion with orwithouta mounting pad. Convenient handholds are pro- vided to manipulate the unit on the jobsite. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3 /4 -in. wide perimeter flange makes frame mounting on a rooftop easy. MODEL NUMBER NOMENCLATURE Model No 48SD - Single Packaged Gas/Electric Unit Low NOx Indicator - Standard N Low NOx Nominal Cooling Capacity 024 - 2.0 Tons 030 -2.5 Tons 036 - 9.0 Tons 042 - 9.5 Tons 048 - 4.0 Tons 060 - 5.0 Tons LEGEND AL — Aluminum CU — Copper 48SD - 024 040 2 Downtlow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal air- flow mode. Integrated Gas Control (IGC) board provides safe and efficient control of heating and simplifies trouble - shooting through its built - in diagnostic function. Cabinets are constructed of heavy - duty, phosphated, zinc coated prepainted steel capable of withstanding 500 hours in salt spray. In- terior surfaces of the evaporator/heat exchanger compartment are insulated with cleanable semi -rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient tem- perature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain minimizes standing water in the drains which is provided with an external drain. Electrical Supply 3 - 208/290 -1 -60 5 - 208/290 -9-60 Heat Input Size (Btuh) 040 - 40,000 060 - 60,000 090 - 90,000 115 - 115,000 190 - 190,000 Options BT - AL evap, vinyl condenser CC - AL evap, CU condenser CU - CUevap&condenser TP - Base unit with tin plated indoor coil hairpins TV - TP with vinyl coating on outdoor col TC - TP with AL indoor coil & CU/CU outdoor coil Only used il ordering an option UNIT 48SD HEATING INPUT (Btuh) OUTPUT CAPACITY (Btuh) TEMPERATURE RISE RANGE ( °F) AFUE (96) --, 40,000 31,000 20 -50 80.1 024060 47.3 48,000 35 -65 78.4 030060 250 48,000 35 -85 78.4 036060 60,000 46,000 25 -55 78.7 042060 87.4 47,000 15 -45 78.7 036090 88,000 70,000 45 -75 79.9 042090 90,000 71,000 35 -65 79.9 048090 90,000 70,000 25 -55 78.6 060090 90,000 70,000 25 -55 78.8 048115 060115 115,000 92,000 35 -65 81.1 048130 060130 130,000 10 40 -70 80.3 UNIT W 48SD Frequency (Hz) 024 030 036 042 048 060 125 54.1 47.3 56.4 56.9 84.0 84.1 250 57.1 58.2 81.0 84.0 69.9 66.8 500 64.9 632 87.4 68.0 73.3 70.6 1000 67.6 68.1 68.1 67.7 73.5 72.6 2000 84.1 64.0 65.8 64.6 70.4 69.8 4000 59.7 81.3 64.8 61.3 66.7 87.5 8000 53.5 57.0 58.8 55.5 60.5 61.8 UNIT 48SD 024040 NOMINAL TONS STANDARD CFM NETCSOODAG CAPACITIES (Btuh) SEEM' SOUND RATINGS$ (dB) 2 800 24,000 13.0 72 024060 OQOOGO 2 -1/2 1000 30,000 13.0 72 036060 036090 3 1200 38,000 13.0 72 042060 3 -1/2 1400 41,500 13.0 73 042090 048090 048115 4 1800 47,000 13.0 78 048130 060090 060115 5 1750 57,000 13.0 78 060130 ARI* CAPACITIES LEGEND db Bulb wb-Wet Bulb SEER-Seasonal Energy Efficiency Ratio • Air Conditioing & Refrigeration Institute. 1 Rated in accordance with U.S. Government DOE Department of Ener- gy) test procedures and/or ARI Standards 210/240 -89. 4 Tested in accordance with ARI Standard 270 -95 (not listed inARI). LEGEND AFUE - Annual Fuel Utilization Efficiency NOTE: Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. LEGEND Sound Levels (10 decibels =1 bet) COOLING CAPACITIES AND EFFICIENCIES HEATING CAPACITIES AND EFFICIENCIES 3 Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 °F db, 67 °Fwb indoor entering -air temperature and 85 °F db outdoor entering -air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. iso 90012000[] OUTDOOR SOUND: OCTAVE BAND DATA - DECIBELS US N co UNIT ELECTRICAL CHARACTERISTICS UNIT WEIGHT UNIT HEIGHT IN N) "�+' CENTER OF GRAVITY IN. [NN) lb kg X Y Z 208/230 343 158 39.02 [991) 20.0 1508] 19.3 (490) 17.6 [447] --> 48SD024 -1-60 485D030 209,x230 -1- 60.208/230 -3 -60 388 166 41.02 (10421 20.0 [508] 14.0 [358) 13.0 [330] BASE UNIT DIMENSIIONS- 48SD024 -030 01001011 0411 01 411 CA ' 11111111111111111111 I '1111111111111111111 II 1 117.1 14. NEC. REQUIRED CLEARANCES. 11111 14141 61141(1 P0111 014111 001111 11.0 11.111 1.0.1. 4 11.1 01. 11011 11:111 REAR VIEW REQUIRED CLEARANCE TO COMBUSTIBLE MATL (Refer to Maximum OperatIngCleaences) TOP OF UNIT.._._._. ..._.. DUCT SIDE OF UNIT.... SIDE OPPOSITE DUCTS ... BOTTOM OF UNIT.. INCHES mm] BETWEEN UNITS, POWER ENTRY SIDE...... 42.00 1066.8) UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE 36.00 14.0) UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE. 42.0011066.8] LEGEND CG • Center of Gravity COND - Candeneor EVAP - Evaporator NEC - National EleWIcal Code REOD - Required NOTE Dimensions are In In. [mm] Min LEFT SIDE VIEW 41.0 11.14 41.1 11.431 316.1 111.131 11.4 11.101 INCHES 1400 . .2.00 1400 0 50 mm) 355 50.8] 356 6) 7 ) 12 11 11 .1 111 .141 1711 3 FRONT VIEW 11.1 11.111 5 4.4 1.111 401.4 111.101 1 11181 0141 C0Y COIL EVAP. COIL ACCESS SIDE POWER ENTRY SIDE (EXCEPT FOR NEC REQUIREMENTS) UNIT TOP SIDE OPPOSITE DUCTS DUCT PANEL... OV1[43 01011 143 10(1101 I I LCC 11 OC(t 11 100(1 7 100 111 -I 131 -0 110.111 111 110.011 REQUIRED CLEARANCE FOR OPERATION AND SERVICING `MINIMUM DISTANCES: IF UNIT IS PLACED LESS THAN 12.00 (304.8) FROM WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISE. 78.611.11 I 10 00.3 10.411- 10x[ 01 11 11111 I 0" ' i 111111111111111111! MEW , 11 1 I 311.6 111 III 141.1 It 111 " :we 11. J/I 111.0 11.811 1100000 TOP VIEW �11.i11 111.1 11.141 INCHES mm) ....36.00 914.0 42 00 1066 ] .....48.00 1219.21 ..36.00 14.0 12.00 .8 8 ' 111 1111 111111111 !111111111111111 11.1 11 101 10.1 101 (1111 1.1 14.101 RIGHT SIDE VIEW A05166 CORNER WEIGHTS (ALL CABINET) CORNER WEIGHTS (LARGE CABINET) Unit 024 030 Unit 038 042 048 060 Total Weight 343 X 88 Total Weight 433 480 480 492 Corner Weight 1 69 74 Corner Weight 1 87 93 97 99 Corner Weight 2 53 57 Corner Weight 2 68 72 74 78 Corner Weight 3 83 88 Corner Weight 3 104 111 118 119 Corner Weight 4 138 147 Corner Weight 4 174 184 193 198 Rigging Weight 353 378 Rigging Weight 443 470 490 502 co 48SD CORNER WEIGHTS Y 1 2 4 x 3 SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: Given: Required Cooling Capacity (TC) 34,000 Btuh Sensible Heat Capacity (SHC) 25,000 Btuh Required Heating Capacity 60,000 Btuh Condenser Entering Air Temperature 95 °F Indoor -Air Temperature 80 °F edb 67 ° F ewb Evaporato r Air Quantity 1200 CFM Extema I Static Pressure 0.1 in. wg Electrica I Characteristics 208 -1 -60 2. Select unit based on required cooling capacity. Enter Net Cooling Capacities table at outdoor entering temperature of 95 ° F. Unit 48SD036 at 1200 cfm and 67 ° F ewb (entering wet bulb) will provide a total capacity of 36,000 Btuh and a SHC of 27,400 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. 3. Select heating capacity of unit to provide design condition requirement. In the Heating Capacities and Efficiencies table on page 4, note that the unit 48SD036090 will provide 70,000 Btuh with an input of 88,000 Btuh. 10 MINIMUM HEIGHT: 36' A05161 4. Determine fan speed and power requirements at design conditions. Before entering the air delivery tables, calculate the total static pres- sure required. From the given example, the Wet Coil Pressure Drop Table, and the Filter Pressure Drop table on page 16, find at 1200 cfm: External Static Pressure 0.10 in. wg Wet Coil 0.059 in. wg Filter 0.13 in. w Total Static Pressure 0.29 in. wg Enter the table for Dry Coil Air Delivery— horizontal and down - flow Discharge on page 15. For 208 v operation, deduct 10% from the value given. At 0.33 ESP (external static pressure), the fan will deliver about 1404 cfm at medium speed. The fan speed should be set at medium speed. 5. Select unit that corresponds to power source available. The Electrical Data table on page 20 shows that the unit is designed to operate at 208 -1 -60. Temp (F) Outdoor Air Entering Condenser Evaporator Au - CFM/BF 875 /0.08 I 1000 /0.09 I 1125 /0.10 Evaporator Air Ewb (F) 57 62 63* 67 72 57 82 63* 67 72 57 62 83* 87 72 TC 26.3 29.1 29.6 32.1 33.9 27.8 29.9 30.4 32.7 34.2 28.6 30.7 31.0 33.1 34.3 75 SHC 26.3 26.3 21.3 22.1 17.2 27.6 28.1 22.8 23.8 17.8 28.6 29.7 24.2 24.8 18.3 kW 22 2.2 2.2 22 22 2.3 2.3 2.3 2.3 2.3 2.3 2.4 2.3 2.4 2.4 1 C 25.4 27.7 28.3 30.7 332 26.8 28.6 29.0 31.5 33.6 27.6 29.5 29.6 32.1 33.9 85 SHC 25.4 25.8 20.8 21.7 17.3 26.6 27.6 22.3 23.3 18.1 27.6 28.8 23.8 24.9 18.9 kW 2.4 2.4 2.4 2.4 2.4 2.5 2.5 2.5 2.5 2.5 2.6 2.6 2.6 2.6 2.6 I C 24.4 28.4 26.8 29.3 32.7 25.5 27.3 27.5 30.0 32.9 28.5 28.1 28.0 30.6 33.4 95 SHC 24.4 25.2 20.2 21.2 16.9 25.5 26.6 21.7 22.8 17.9 26.5 27.9 23.2 24.3 18.8 kW 2.6 2.6 2.6 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.8 2.8 2.8 2.8 2.8 TC 23.4 25.0 25.4 27.7 31.1 24.5 25.9 26.0 28.3 31.8 25.4 28.9 26.4 28.9 ' 32.3 105 SHC 23.4 24.4 19.6 20.6 16.3 24.5 25.8 21.1 22.2 17.3 25.4 26.7 22.5 23.7 18.3 kW 2.9 2.9 2.9 2.9 2.9 2.9 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.1 3.1 TC 22.3 23.7 23.8 26.1 29.3 23.4 24.7 24.4 28.7 30.0 24.2 25.7 24.8 27.1 30.5 115 SHC 22.3 23.4 19.0 20.0 15.7 23.4 24.8 20.5 21.6 16.7 24.2 25.5 21.9 23.1 17.7 kW 3.1 3.1 3.1 32 3.2 32 32 3.2 3.3 3.3 3.3 3.3 3.3 3.4 3.4 1 C 21.1 22.3 22.1 24.4 27.6 22.1 23.4 22.6 24.9 28.1 23.0 24.3 23.1 25.4 28.8 125 SHC 21.1 22.2 18.3 19.4 15.1 22.1 23.3 19.8 20.9 18.1 23.0 24.2 21.1 22.4 17.1 kW 3.4 3.4 3.4 3.5 3.5 3.5 3.5 3.5 3.8 3.8 3.8 3.8 3.8 3.7 3.7 Temp (F) Outdoor Air Entering Condenser Evaporator Air - CFM/BF 700 / .08 I 800/0.10 I 900 / 0.11 Evaporator Air Ewb (F) 57 82 83* , 87 72 57 62 63* 67 72 57 62 63* 67 72 TC 21.0 23.2 23.6 25.6 29.0 22.0 23.9 24.2 26.1 28.0 22.9 24.5 24.7 26.5 28.3 75 SHC 21.0 21.1 17.1 17.8 14.7 22.0 22.8 18.3 19.1 14.7 22.9 24.3 19.5 20.2 15.3 kW 1.7 1.7 1.7 1.7 1.7 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 1.9 1.9 TC 202 222 22.6 24.5 27.1 21.2 22.9 23.1 252 27.6 22.1 23.8 23.6 25.6 27.9 85 SHC 202 20.7 16.6 17.4 13.9 21.2 22.3 17.9 18.7 14.7 22.1 23.4 19.0 20.0 15.4 kW 1.9 1.9 1.9 1.9 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.1 TC 19.5 212 21.5 23.4 26.1 20.4 21.9 22.1 24.0 26.7 21.2 22.7 22.5 24.4 27.1 95 SHC 19.5 202 162 16.9 13.8 20.4 21.7 17.4 182 14.4 212 22.5 18.5 19.5 15.2 kW 2.1 2.1 2.1 2.1 2.1 2.2 2.2 22 2.2 2.2 2.2 2.3 2.3 2.3 2.3 TC 18.7 20.1 20.4 22.3 24.9 19.6 21.0 20.9 22.8 25.5 20.4 21.8 21.3 23.2 25.9 105 SHC 18.7 19.6 15.7 16.4 13.1 19.6 20.8 16.9 17.7 14.0 20.4 21.6 18.0 19.0 14.8 kW 2.3 2.3 2.3 2.3 2.4 2.4 2.4 2.4 2.4 2.4 2.5 2.5 2.5 2.5 2.5 1 C 17.8 19.0 192 21.0 23.6 18.6 20.0 19.7 21.5 24.1 19.4 20.8 20.1 21.9 24.5 115 SHC 17.8 18.9 15.1 15.9 12.7 18.6 19.8 16.3 172 13.5 19.4 20.6 17.5 18.5 14.3 kW 2.5 2.5 2.5 2.6 2.6 2.6 2.6 2.6 2.7 2.7 2.7 2.7 2.7 2.7 2.8 1 C 16.8 18.0 17.9 19.7 22.2 17.8 18.9 18.3 20.1 22.6 18.3 19.8 18.7 20.5 23.0 125 SHC 16.8 17.8 14.6 15.4 12.1 17.8 18.7 15.8 16.7 13.0 18.3 19.4 16.9 17.9 13.8 kW 2.8 2.8 2.8 2.8 2.9 2.9 2.9 2.9 2.9 2.9 3.0 3.0 3.0 3.0 3.0 PERFORMANCE DATA 48SD 024 Cooling Performance Table 48SD 030 Cooling Performance Table See Legend and Notes on page 13. 11 U, co cr Unit Heating Rise Range ( °F) Motor Speed External Static Pressure (WC) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 48S13(— ,N)024040 20 — 50 Low1 Watts 311 309 304 301 286 — — — — — — — — CFM 935 885 820 757 686 — — — — — — — — Heating Rise ( °F) 32 34 37 40 44 -- -- -- -- Medium Watts — — — — — — — — 379 357 357 345 — — CFM -- -- -- -- 957 868 769 647 -- Heating Rise ( °F) -- -- -- -- 31 35 39 46 -- High Watts — — — — — — — — — — — — 447 435 421 CFM -- -- -- -- -- -- 970 853 712 Heating Rise (°F) — _ -- -- -- -- — — 31 35 42 48SD(— ,N)024060 35 — 65 Low.' Watts 311 309 304 301 — — — — — — — — — — CFM 935 885 820 757 — — — — — — — — — — Heating Rise ( °F) 48 51 55 59 -- -- -- -- -- Medium Watts 411 405 398 390 379 357 357 — — — — CFM 1195 1155 1100 1028 957 868 769 -- -- Heating Rise (°F) 38 39 41 44 47 52 59 — — — — High W a t t s -- -- -- -- -- -- 447 435 421 CFM -- -- -- -- -- -- 970 853 712 Heating Rise ( °F) __ -- -- -- -- -- 46 53 63 48SD(— ,N)030040 20 — 50 Low Watts 311 309 304 301 -- -- -- -- -- CFM 935 885 820 757 — — — — — — — — — — Heating Rise ( °F) 32 34 37 40 — — — — — — — — — — Mediums Watts 411 405 398 390 379 357 357 — — — — CFM 1195 1155 1100 1028 957 868 769 — — — — Heating Rise ( °F) 25 26 27 29 31 35 39 — — — — High Watts — — — — — — — — 477 467 447 435 — — CFM — — — — — — — — 1185 1088 970 853 — — Heating Rise ( °F) — — — — — — — — 25 28 31 35. — — 48SD(— ,N)030060 35 — 65 Low Watts 1 311 309 304 301 -- -- -- -- -- CFM 935 885 820 757 — — — — — — — — — — Heating Rise ( °F) 48 51 55 59 -- -- -- -- -- Medium1 Watts 411 405 398 390 379 357 357 — — ' — — CFM 1195 1155 1100 1028 957 868 769 -- -- Heating Rise (°F) 38 39 41 44 47 52 59 — — — — High Watts — — — — — — — — 477 467 447 435 — — CFM -- -- -- -- 1185 1088 970 853 -- Heating Rise ( °F) -- -- -- -- 38 41 - 46 53 - -- to co v PERFORMANCE DATA CONTINUED Table 13 - Dry Coil Air Delivery* - Horizontal and Downflow Discharge - Unit 48SD024 -060 (Deduct 10% for 208 Volts) 14 UNIT SIZE V -PH -HZ VOLTAGE RANGE COMPRESSOR OUTDOOR FAN MOTOR INDOOR FAN MOTOR POWER SUPPLY Min Max RLA LRA FLA FLA MCA OR FUSE 208/230 -1-60 187 253 13.5 61.0 0.8 4.3 17.1/17.1 20/20 024 030 208/230 -1-60 187 253 15.9 73.0 0.8 4.3 21.0/21.0 25/25 208/230 -3-60 187 253 9.0 63.0 0.9 2.0 152/15.2 20/20 036 208/230 -1-60 187 253 16.9 83.0 0.8 6.8 24.8/24.6 30/30 208/230 -3-60 187 253 10.2 77.0 0.9 3.1 17.9/17.9 25/25 460 -3-60 414 506 5.1 44.0 0.6 1.9 9.8/9.8 15/15 042 208/230 -1-60 187 253 22.4 105.0 0.8 6.8 28.6/28.6 35/35 208/230 -3-60 187 253 12.4 88.0 0.9 4.1 20.2/202 25/25 460 -3-60 414 506 5.6 44.0 0.6 1.9 9.8/9.8 15/15 048 208/230 -1-60 187 253 21.3 109.0 1.6 6.8 29.0/29.0 35/35 208/230 -3-60 187 253 12.4 88.0 1.5 4.1 20.2/20.2 25/25 460-3-60 414 506 5.4 44.0 0.9 1.9 9.8/9.8 15/15 060 208/230 -1-60 187 253 27.0 145.0 1.6 9.1 39.5/39.5 50/50 208/230 -3-60 187 253 17.3 123.0 1.5 6.2 29.3/29.9 35/35 460 -3-60 414 506 7.7 49.5 0.9 2.7 13.5/13.5 20/20 ELECTRICAL DATA FLA - LRA - MCA -- MOCP - RLA - LEGEND Full Load Amps Locked Rotor Amps Minimum Circuit Amps Maximum Overcurrent Protection Rated Load Amps US NO TES: 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse. The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on 80 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. 3. Unbalanced 3 -Phase Supply Voltage Never operate a motor where a phase imbalance in supply vort- age is greater than 2%. Use the following formula to determine the percentage of voltage Imbalance % \bltage imbalance = 100 x max voltage average deviation from erage voltage average voltage Heater capacity (kW) based on heater voltage of 208v & 240v. * If power distibution voltage to unit varies from rated heater voltage, heater kW will vary accordingly. 21 EXAMPLE: Supply voltage is 230 -3-60. A B C AB = 228 v BC = 231 v AC = 227 v Average Voltage - 228 + 231 + 227 686 3 = 229 3 Determine maximum deviation from average voltage. i AB) 229 - 228 = 1 v BC) 231 - 229 = 2 v AC)) 229 - 227 = 2 v Maximum deviation is 2 v. Determine percent of voltage imbalance % Voltage Imbalance = 100 x 2 229 = 0.8% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2 %, contact your local electric utility company immediately. i_oad Express: Load Calculation Software General Job Job Description: Building Owner: Program User: Comments: GE Seattle Mechanical Program was Run: 2/26/2008at 10:08:01 AM Dataset Name: C:1CDS \LOADEXP\DATA\GE.LE Alternative 1 AIt1 Geographical Data Location: Tukwila Weather File: Seattle, Washington Latitude: 47 deg Elevation: 386 ft Load Express: Load Calculation Software By: Seattle Mechanical Design Data Summer Dsn Dry Bult Summer Dsn Wet Bul Winter Design Dry Bu Density -Sp Heat Prod Design Simulation pet FILE COPY Permit No. 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu- min/(hr -ft3-F) Apr To Nov Version 2.2 Title Page Building Peak Data Month/Hour: Jul / 14 Cooling Capacity: 13.7 Mbh Cooling Sensible: 11.0 Mbh Sensible Heat Ratio (SH 0.881 Heating Capacity -22.2 Mbh CITY Or TUtiWILA MAP, n 32008 PERMIT CENTER MO toad Express: Load Calculation Software Version 2.2 Zone /Air Handler Descriptions Alternative - 1 AIt1 Zone /Air Handler Descriptions Air Handler Type Description 1 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zonal Load Express: Load Calculation Software Alternative 1 AIt1 General Job Data Weather Location: Seattle, Washington Weather Region: Northwest Clg Simulation Start Month: Apr Clg Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 25 ft Floor Length: 10 ft Ceiling Height: 10 ft Fir -to -Fir Height: 16 ft No. of Dup Zones: 1 Ceiling U- Factor: 0.00 Btu /(hr- F -ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.73 Btu /(hr -F -ft) Floor Perimeter Length70.00 ft W H ft ft WALL 1 25 x 10 GLASS 1 6 x 7 ROOF 1 25 x 10 PART 1 25 x 10 PART 2 10 x 10 PART 3 10 x 10 Type 8" common brick, 3.33" Ins Double Clear 1/4 in. 4" H.W. Ok, SusClg, 6" Ins Frame, 0.75" gypsum board Frame, 0.75" gypsum board Frame, 0.75" gypsum board 1 -2 Story Office Building Opening Time: 7 am Building Closing Time: 6 pm Building Direction: 0 Clg Sensible SF: 10.00 Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RA Lighting Intensity: Lighting Type: ecessed fluorescent, not vented 0.07 Light 0.60 0.04 Dark 0.39 0.39 0.39 North 0 Plenum 0 RA North 74 deg F 50 % 72 deg F 100 ft2/pers General Office Space 210 Btuh /pers 255 Btuh /pers Microcomputers 350.00 Watt/pers 0.00 Watt/ft2 0 Btuh 2.00 Watt/ft2 0 0 Yes 0 0 0 0 Clg Latent SF: 10 Htg Sensible SF: 10 People Diversity: 100 % Bldg Simulation Type: Cooling and Heating Version 2.2 Zone Input Data Ballast Factor: 1.00 % Percent Light to RA: 0 % Vent Type: General Office Space Vent Cool Design: 40.00 cfm /pers Vent Heat Design: 40.00 cfm /pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Poor Construction Infilt. Cooling Desigi 0.50 ach /hr Infilt. Heating Desigi 0.50 ach /hr Room Exhaust 0.00 cfm U- Factor Color Percent ( %) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp deg F deg F 0 0 0 0 Area 0 0 90 40 90 40 90 40 0.00 0.82 0.00 0.00 0.00 0.00 Shading No Shading Load Express: Load Calculation Software Version 2.2 Air Handler Input Air Handler Input Alternative 1 (Air Handler 1 Fan Configuration: Fan & Motor Efficiency: Cooling Supply Air Temp: Heating Supply Air Temp: Minimum Relative Humidity: Supply Fan Static Pressure: Retum Fan Static Pressure: CONSTANT AHU1 Draw 56.00 % 55.00 deg F 0.00 deg F 50 % 2.50 in H2O 2.00 in H2O Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Unvented Space R4 Duct Insulation 0.5 deg F TD R4 Duct Insulation 0.3 deg F TD CONSTANT 0 cfm 0 cfm 1 Load Express: Load Calculation Software versio2.2 Peak Load Information Alternative 1 Design Heating: Airflow (cfm) Space Total Heating Coil Total Outside % O.A. Sensible Sensible Entering Leaving Humidification Air Handler #!Type Btuh Btuh DB DB Btuh BLDG BLOCK - 12,392.50 - 22,199.90 - 3,861.3 BLDG PEAK - 12,392.50 - 22,199.90 - 3,861.3 1 CONSTANT 470.94 100.00 21.23 - 12,392.50 - 22,199.90 61.26 95.95 - 3,861.3 Design Cooling: Air Handler If/ Type BLDG BLOCK BLDG PEAK 1 CONSTANT Building Peak Load Components Airflow (cfm) Total Outside % O.A. 470.94 100.00 21.23 Cooling Cooling Coil Total Sensible S.H.R. Entering Leaving ft2iton cfmlton cfm/ft2 Total Btuh Btuh DB WB DB WB tons 13,735.00 12,094.90 0.88 218.42 1.1 13,735.00 12,094.90 0.88 218.42 1.1 13,735.00 12,094.90 0.88 76.49 61.42 52.87 51.15 218.42 411.5 1.9 1.1 Cooling (Btuh) Heating (Btuh) Mo&Hr: Solar Cond Internal OA+Inf Misc Total Cond OA +Inf Misc Total Bldg 7/14 1,081.8 2,880.4 5,413.7 1,570.4 1,540.0 12,486.3 - 10,212.8 - 6,107.6 - 3,861.3 - 20,181.7 Air Hand 1 7/14- 1,081.8 2,880.4 5,413.7 1,570.4 1,540.0 12,486.3 - 10,212.8 - 6,107.6 - 3,861.3 - 20,181.7 Zone 1 7/14 1,081.8 2,880.4 5,413.7 1,570.4 1,540.0 12,486.3 - 10,212.8 - 6,107.6 - 3,861.3 - 20,181.7 Load Express: Load Calculation Software Psychrometric State Points - Altemative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zonel ( deg F ) ( deg F ) ( deg F ) Space 74.9 60.0 Zone Retum Air Heat Pickup 0.3 Return Fan 1.3 Return Air 75.6 60.6 Outdoor Air 79.4 64.3 Retum/Outdoor Air Mix 76.5 61.4 Blow Through Fan 0.0 Entering Coil 76.5 61.4 Leaving Coil 52.9 51.2 Draw Through Fan 1.6 Supply Duct Heat Gain 0.5 Supply Air 55.0 52.1 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 23.36 % 0.933 428 cfm Version 2.2 Psychrometrics Load Express: Load Calculation Software Version 2.2 Sensible Load Profile Sensible Load Profile (Mbh)- Altemative 1 AIt1 Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 4 3 3 3 3 3 8 8 9 9 10 10 11 11 11 11 11 11 7 5 5 4 4 4 Bldg 4 3 3 3 3 3 8 8 9 9 10 10 11 11 11 11 11 11 7 5 5 4 4 4 Zone 1 4 3 3 3 3 3 8 8 9 9 10 10 11 11 11 11 11 11 7 5 5 4 4 4 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 250.0 70.0 250.0 0.0 208.0 42.0 450.0 AIt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 8,938.3 Btuh 9,832.2 Btuh 428 cfm 471 cfm 1.71 cfrn /ft2 1.88 cfm/ft2 428 cfm 471 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mohr: Outside Air: OADB: WB: RELHUM: 7 / 14 79 64 44.2% - 515F Load ( Btuh) Cooling Coil Peak Sens Load Percnt ( Btuh ) of Tot ( %) Heating Coil Peak Peak Tot Sens Percnt of Tot ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 1,081.81 1,081.81 0.00 Sub Total 1,081.81 1,081.81 8.66 • 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 61.98 61.98 - 414.00 Glass 74.89 74.89 - 1,220.08 Wall -35.68 -35.68 - 669.76 Partition 2,779.20 2,779.20 - 5,558.40 SlabOnG /ExFIr 0.00 0.00 - 2,350.60 Sub Total 2,880.39 2,880.39 23.07 - 10,212.80 50.60 INTERNAL LOADS Lights 1,495.89 1,495.89 0.00 People 1,127.95 490.45 0.00 Misc 2,789.83 2,789.83 0.00 Sub Total 5,413.67 4,776.17 43.36 0.00 0.00 MISC LOADS Outside Air 1,299.66 593.36 - 5,054.58 Humidification 0.00 0.00 - 3,861.29 Infiltration 270.76 123.62 - 1,053.04 Sup. Fan Heat 764.52 764.52 0.00 Ret. Fan Heat 611.61 611.61 0.00 Duct Heat Pkup 376.35 376.35 0.00 Exhaust Heat - 212.45 - 212.45 0.00 Sub Total 3,110.45 2,257.01 24.91 - 9,968.90 49.40 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 12,486.30 10,995.40 - 20,181.70 W /Safety Factor 13,735.00 12,094.90 - 22,199.90 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Air Hand 1 AHU1 Areas ( ft2 ) Floor: SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 250.0 70.0 250.0 0.0 208.0 42.0 450.0 AIt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 8,938.3 Btuh 9,832.2 Btuh 428 cfm 471 cfm 1.71 cfrn /ft2 1.88 cfm/ft2 428 cfm 471 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mohr: Outside Air: OADB: WB: RELHUM: 7 / 14 79 64 44.2% Load Express: Load Calculation Software Peak Load Summary - Alternative 1 AIM Bldg 1 Areas ( ft2 ) Floor. 250.0 SlabOnG/ExFIr: 70.0 Roof: 250.0 Skylight: 0.0 Wall: 208.0 Wall Glass: 42.0 Partition: 450.0 Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air. OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) 1 %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 1,081.81 1,081.81 0.00 Sub Total 1,081.81 1,081.81 8.66 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 61.98 61.98 - 414.00 Glass 74.89 74.89 - 1,220.08 Wall -35.68 -35.68 - 669.76 Partition 2,779.20 2,779.20 - 5,558.40 SlabOnG/ExFIr 0.00 0.00 - 2,350.60 Sub Total 2 2,880.39 23.07 - 10 50.60 INTERNAL LOADS Lights 1,495.89 1,495.89 0.00 People 1,127.95 490.45 0.00 Misc 2,789.83 2,789.83 0.00 Sub Total 5,413.67 4,776.17 43.36 0.00 0.00 MISC LOADS Outside Air 1,299.66 593.36 - 5,054.58 Humidification 0.00 0.00 - 3,861.29 Infiltration 270.76 123.62 - 1,053.04 Sup. Fan Heat 764.52 764.52 0.00 Ret. Fan Heat 611.61 611.61 0.00 Duct Heat Pkup 376.35 376.35 0.00 Exhaust Heat - 212.45 - 212.45 0.00 Sub Total 3,110.45 2,257.01 24.91 - 9,968.90 49.40 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 12,486.30 10,995.40 - 20,181.70 W /Safety Factor 13,735.00 12,094.90 - 22,199.90 Load Express: Load Calculation Software Peak Load Summary - Alternative 1 AIM Bldg 1 Areas ( ft2 ) Floor. 250.0 SlabOnG/ExFIr: 70.0 Roof: 250.0 Skylight: 0.0 Wall: 208.0 Wall Glass: 42.0 Partition: 450.0 Version 2.2 Peak Load Summary Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air. OADB: 79 WB: 64 RELHUM: 44.2% Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Altemative 1 Zone 1 Zonal Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 250.0 70.0 250.0 0.0 208.0 42.0 450.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 8,938.3 Btuh 9,832.2 Btuh 428 cfm 471 cfm 1.71 cfm/ft2 1.88 cfm/ft2 428 cfm 471 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: Outside Air. OADB: WB: RELHUM: 7 / 14 79 64 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh) ( %) ( Btuh) ( %) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 1,081.81 1,081.81 0.00 Sub Total 1,081.81 1,081.81 8.66 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 61.98 61.98 - 414.00 Glass 74.89 74.89 - 1,220.08 Wall -35.68 -35.68 - 669.76 Partition 2,779.20 2,779.20 - 5,558.40 SlabOnG /ExFIr 0.00 0.00 - 2,350.60 Sub Total 2,880.39 2,880.39 23.07 - 10,212.80 50.60 INTERNAL LOADS Lights 1,495.89 1,495.89 0.00 People 1,127.95 490.45 0.00 Misc 2,789.83 2,789.83 0.00 Sub Total 5,413.67 4 776.17 _ 43.36 0.00 0.00 MISC LOADS Outside Air 1,299.66 593.36 - 5,054.58 Humidification 0.00 0.00 - 3,861.29 Infiltration 270.76 123.62 - 1,053.04 Sup. Fan Heat 764.52 764.52 0.00 Ret. Fan Heat 611.61 611.61 0.00 Duct Heat Pkup 376.35 376.35 0.00 Exhaust Heat - 212.45 - 212.45 0.00 Sub Total 3,110.45 2,257.01 24.91 - 9,968.90 49.40 OV /UNDR Sizing 0.00 0.00 0.00 Grand Total 12,486.30 10,995.40 - 20,181.70 W /Safety Factor 13,735.00 12,094.90 - 22,199.90 Load Express: Load Calculation Software Version 2.2 Peak Load Summary Peak Load Summary - Altemative 1 Zone 1 Zonal Areas ( ft2 ) Floor: SlabOnG /ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 250.0 70.0 250.0 0.0 208.0 42.0 450.0 Alt1 Space Sens Load Spc Sens Ld W /Sfty Fctr Cool Airflow Cool Airflw W /Sfty Fctor Cooling Check Cool Check W /Sfty Fctr Heat Airflow Heat Airflw W /Sfty Fctr 8,938.3 Btuh 9,832.2 Btuh 428 cfm 471 cfm 1.71 cfm/ft2 1.88 cfm/ft2 428 cfm 471 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo /Hr: Outside Air. OADB: WB: RELHUM: 7 / 14 79 64 44.2% Building Division Review Memo Date: March 5, 2008 Project Name: GE Permit #: M08 -060 Plan Review: Allen Johannessen, Plans Examiner • Page 1 Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide details that show how the new RTU shall be secured to resist forces of seismic and wind. (2006 IMC 301.12 & 301.15) Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. March 6, 2008 Terry Course 899 West Main Auburn, WA 98001 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -060 GE —12600 Interurban Avenue S Dear Mr. Course, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sipcerely, Brenda Permit Coordinator Encl [4- xc: File No. M08 -060 • Cizy of Tukwila Department of Community Development Jack Pace, Director P:\Pennit Center \Correction Letters \2008\Ivf08 -060 Correction Ltr 41.130C wer • Jim Haggerton, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: M08 -060 DATE: 03 -10 -08 PROJECT NAME: GE SITE ADDRESS: 12600 INTERURBAN AV S Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ing 'Division Public Works Complete Comments: -vt k os n APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 • PERMIT COORD COPY. PLAN REVIEW /ROUTING SLIP Fire Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: n Planning Division ❑ Permit Coordinator No further Review Required DATE: DATE: n n DUE DATE: 03-1 1 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n DUE DATE: 04-08-08 Approved Approved with Conditions 71 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -060 DATE: 03 -03 -08 PROJECT NAME: GE SITE ADDRESS: 12600 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: id uI VI Public Works U PLAN REVIEW /ROUTING SLIP Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete Comments: REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28 -02 &PERMIT COORD COPY • 6n .3-41 Fire Prevention aj DUE DATE: 03-04-08 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required I No further Review Required DATE: DUE DATE: 04-0 1 -08 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Planning Division Permit Coordinator Not Applicable n Permit Center Use Only CORRECTION LETTER MAILED: $• (POT) Departments issued corrections: Bldg (r Fire ❑ Ping ❑ PW ❑ Staff Initials: & City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the malt, fax, etc. Date: Plan Check/Permit Number: 1/V1 0 0 G`6 ❑ Response to Incomplete Letter # Response to Correction Letter # C/7yROFC'Fi`f0 UK E l Revision # after Permit is Issued / O � 1:3 Revision requested by a City Building Inspector or Plans Examiner Ff�j 20 08 Project Name: ( - C Project Address: 0 it e r UN\ v /-U r mac4 k W,nlc Contact Person: (N* 1 C o LLc Phone Number: �� - e l f - 9 L-1 S Summary of Revision: plo\J d e A e ` `` ( 121 (" In Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision n Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 0 b \applicationskfbnns- applications on lineVevision submittal Steven M Mullet, Mayor Steve Lancaster, Director License Information License IECS * * *044QL Licensee Name IECS INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601639846 Ind. Ins. Account Id Business Type CORPORATION Address 1 PO BOX 19252 Address 2 City SEATTLE County KING State WA Zip 981091252 Phone 2064694153 Status ACTIVE Specialty 1 AIR CONDITIONING Specialty 2 UNUSED Effective Date 11/13/1996 Expiration Date 11/20/2008 Suspend Date Separation Date Parent Company Previous License Next License SEATTMI038NR Associated License Business Owner Information Name Role Effective Date Expiration Date HUMPHREY, GEORGE 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information No Matching Information Savings Information Savings Bank Name Bank Branch Location Assignment of Savings Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date Page 1 of 3 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License =IECS* * *044QL 03/14/2008 SITE PLAN N.T.S. FILE_COP Permit No. By Date 7 /7 / / City of Tukwila ET'DING DIVISION TiIE HORN NORTH SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical se Electrical Plumbing Gas Piping City of Tukwila BUILDING pivisioN Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fj . py and ..» . r . acknowledged: do t Er 3LF°�d s 3.3 e LOCATION: 'I ti Grp P 4f ' 2 7 ilaa �illr 1 -- i it 4 4 `'.� 5 Luz! ..,7•y= VICINITY MAP . Li 3 : w.= lM' t L Lk r E 1 ■s d a Vo4 PARCEL MISER: 0004800003 ACCOLt4T NUMBER : 000450000306 .3 'I s REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. PROJECT AND BUILDING DATA BUILDING CODE: 2006 IBC WITH WASHMGTON W/ STATE AMENDMENTS TUKWILA COMMERCE PARK, BUILDINA A 12600 MERMAN AVE. 5., SUITE 110 TUKWILA, WA CONSTRUCTION TYPE: V -B SPRI1KLERED OCCUPANCY CROUPS} GROUP B OFFICE ZONE: c / L -I LOT AREA: 465 ,295 SQ Fr (I068 ACRES) TENANT SUITE AREA: OFFICE: 250 S.F. WAREHOUSE: 3209 SF. TOTAL: 3,459 SF. PARCMCz NO GRANGE SCOPE: CONSTRUCT NEW OFFICE FOR TENANT TO INCLUDE NON- BEARING WALLS AND SUSP. ACOUSTICAL CEILING. ENVELOPE: NEW OFFICE AREA TO HAVE WALLS INSULATED W/ R -I9 BAtt t CEILft MUTED W/ R - 30 BATT INSULATION. LEGAL DESCRIPTION LEWI5 C C -D C • 31 BECK N 81 -44 -I5 E 199.11 FT FROM HUB AT END OF CURVE ON CENT LN OF IU UJAMISH- Ra4TON JUNCTION RD GO HUB BENG APPROx 1200 FT N AND 440 FT W OF 1/4 COR BET SECS 14 4 15 -23 -4 TH N 49 -24 -00 W 253$ FT TH N 09 -36 -00 E 52 FT TO TRUE BEG TI4 82 -40 -30 E 590 FT TI-1 N 59 -22 -30 E 64335 FT TI-1N 01 -51 -30 W 343 FT TO LEFT BANK OF DUWAMISH RIVER BEING NLY BOIXDRY OF LEWIS ID G T1-1 SILT ALG SD BANK c RIVER TO PT N 00 -39 -40 W OF TRUE BEG TR S 00 - 39 - 40 E TO TRUE BEG ALSO POR OF D C LY W aF ABOVE DESCRIBED LAND SLY 16.15 Fr AND A 16 FT STRIP ADJ AND PARL TO ELY LN OF RNI O1= P S ELEC CO FOR JOINT RD TGW LOT 41 OF PLAT OF RVERSIDE INTERURBAN MS r- CD CD CID 0303 co cfl 0 0 N 0 as o W � Z rfi z -x4 r4 Ao co T-0 CIT OF TUKVNLA MAP n 3 7008 PERMIT CENTER N if, = r ^r f '4. .. ,, _y� r. LEGEND Return * VOW qppply dif how 6NikMd duct Thocincatat 4 RECESSED 2X4-2 TUBE, T -8 FLUORESCENT 66 WATTS UHT FIXTURE FIXTURE W/ PARABOLIC LENSE TOTAL PROPOSED WATTAGE = TOTAL Allow WATTAQE = 1 WATT / S.F. X 250 S.F. = 250 WATTS GENERAL NOTES 1, NEW OFFICE AREA TO BE PROVIDE VNTH FULL HVAC. . 2Q06 International Mechanical Code (il!IC) Able thermostat w /night setback Equipment Schedule ' EM DESCRIPTION NEW 2 TON ROOF TOP GAS /AC UNIT TO NEW WORK AND DIFFUSERS. RUN NEW 1" GAS LINE gXISITING GAS LINE TO NEW ROOF TOP UNIT. UNIT WEIGHT 343 NORTH 1 14" 1 existing gas unit heat I I Exisiting gas meter immorim 14'4 coneect of existing gas h exisiting gas line 4 '4 � New roof top unit NEW 1' gas b 2 line up to unit EX. WAREHOUSE NO CHANGE TO ENVELOPE & NEW LIGHTING NOT TO EXCEED 0.5 WATTS / S.F. REFLECTED CEILING PLAN 22' ELEVATION VIEW EAST NTS NORTH NORTH se g ROOF PLAN 1/8° =1' -a' NEW OFFICE Li 250 S.F. OCCUPANT LOAD = 2.50 New roof top unit EX. WAREHOUSE 3,209 S.F. OCCUPANT LOAD = 6.42 N —IDOSTING DEMISING WALL EXISTING DEMISING WALL EXISTING CONCRETE WALL A I B KEY PLAN N.T.S. tio � g EX. RR _z RIEWEPy FOP CODE C CE 1 Of Tuktt4i7 RBCE,. CITY OF TukWILA M n 31008 PERMIT CENTER U u7 0 N CD CD r7 0) 0) to to Lo N N w O x 4J z N a F4 x ICJ CC (ID CD ( 1 I ( 1- U 1 Equipment Schedule Tag Make Model CFM Cooling SEER Net Heating BTU'S AFUE OA CFM V /Ph SOUND RATTING UNIT WEIGHT db's RTU -1 CARRIER 48SD0240403 800 13 24,000 40,000 80.1% 100 208/1 72 343 neti LEGEND Return air diffuser Supply diffuser ust fah Unlined duct Lined duct Thermostat Damper • Seven day programmable thermostat w /night setback RECESSED 2X4 -2 TUBE T-8 F_UC'PE; EN i 66 WATTS LIGHT FIXTURE flX JR'E ` ?/ PAPABOIC LENSE. TO L PROPOSED VJATTAGE TOTAL ALLOWABLE WATTAGE = i WATT / S.F. X 250 S.F. = 250 WATTS GENERAL NOTES 1. N`',i p ()HOE C'E AREA TO BE PROVIDE 1 i - �; i 2. 2D08 . _e t or c [Uechonicci Code (IMC) VAC. SYSTEM DESCRIPTION INSTALL NEW 2 TON ROOF TOP GAS /AC UNIT TO NEW DUCT WORK AND DIFFUSERS. RUN NEW 1" GAS LINE FROM EXISITING GAS LINE TO NEW ROOF TOP UNIT. roof curb NEW ROOFTOP UNIT r �� 4 -12# screws per side CURB DETAIL NTS 1 14" I 1 Exisiting gas meter s unit heat, exisiting gas line 14'0 coneect of e isting gas /here New roof t 40 NEW 1 gas line up to unit ur i EX. WAREHOUSE NO CHANGE TO ENVELOPE & NEW LIGHTING NOT TO EXCEED 0.5 WA ITS / S.P. REFLECTED CEILING ]. AN 22' ELEVATION VIEW EAST NTS 1/8"=1:-0" NOWT NORTH I E pri me VM4�r1i Nl a ... "' ea w H 1 I 7 N " i ....1/Mi nl i - rE - ANT SPACE UNDER THIS PERMIT Ci I I AREA OF WORK UNDER THIS FERMI NORTH L i\ hn/ l - 11-rI 230 S.E. OCCUPANT LOAD ROOF PLAN 1/8" =1' —O" EXISTING CONiCRE E VIA.. New roof top unit f�. N.T.S. 1 EX. WAREHOUSE 3,209 S.P. OCCUPANT LOAD = 6.42 3 V 7-` T 9. -L-21 1 J \ EXISTING DEMISING WALL EXIS?1NG DEMISING WALL — EX. RR CITY OF7trw;L MAR 10 7008 PERMIT CENTER R L ' ®� L..:„._„ EV CORRECTION —0(e0 Z -a E 10 W n cn LC) O a) CD rn rn I I CO 01 W Q a Zz� �.o <1 : z0 1Q W co S QC) U I IL 0 0 O 0 0