Loading...
HomeMy WebLinkAboutPermit M08-061 - WESTFIELD SOUTHCENTER MALL - FYEFYE 2636 SOUTHCENTER MALL M08 -061 Parcel No.: Address: Suite No: 6364200010 2636 SOUTHCENTER MALL TUKW Tenant: Name: FYE Address: 2636 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DEVON REDMON Address: 1327 POST AV, STE H , TORRANCE CA Contractor: Name: CONSTRUCTIVE BLDG SERVICES INC Address: 3937 39 AVE , OAKLAND CA Contractor License No: CONSTBS994D8 DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL VAV BOX TIED INTO MALL CENTRAL SUPPLY AIR SYSTEM. INSTALL DIFFUSERS, DUCT WORK, AND THERMOSTATS. Value of Mechanical: $13,000.00 Type of Fire Protection: SPRINKLERS CityOf Tukwila Furnace: <100K BTU >100K BTU Floor Furnace Suspended/Wall/Floor Mounted Heater Appliance Vent Repair or Addition to Heat/Refrig /Cooling System.... Air Handling Unit <10,000 CFM >10,000 CFM Evaporator Cooler Ventilation Fan connected to single duct Ventilation System Hood and Duct Incinerator: Domestic Commercial/Industrial doc: IMC -10/06 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT • EQUIPMENT TYPE AND OUANTITY 0 0 0 0 0 0 0 0 0 1 0 0 0 0 * *continued on next page ** Permit Number: Issue Date: Permit Expires On: M08 -061 OS/20/2008 11/16/2008 Phone: Phone: 310 328 -6300 X101 Phone: 510 - 531 -1175 Expiration Date: 05/20/2010 Fees Collected: $316.25 International Mechanical Code Edition: 2006 Boiler Compressor: 0-3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 12 Thermostat 2 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment 2 M08 -061 Printed: 05 -20 -2008 Permit Center Authorized Signature: II I Print Name: „AI The granting of this construction or Signature: doc: I MC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us LW Permit Number: MO8 -061 Issue Date: 05/20/2008 Permit Expires On: 11/16/2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work ' ' be complied with, whether specified herein or not. does not presume to give authority to violate or cancel the provisions of any other state local laws regulating ance • - . authorized to sign and obtain this mechanical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -061 Printed: 05-20 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Parcel No.: 6364200010 Address: 2636 SOUTHCENTER MALL TUKW Suite No: Tenant: FYE Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 - 061 Status: ISSUED Applied Date: 03/03/2008 Issue Date: OS/20/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 - 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air- moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) doc: Cond -10/06 M08 -061 Printed: 05-20 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 18: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 19: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * *continued on next page ** M08 -061 Printed: 05-20 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Signature: The granting of thi ance of work. oes not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or th Print Name: ! : .11 doc: Cond -10/06 M08 -061 Printed: 05-20 -2008 CITY OF TUKWILA Community Development Department Public Work Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 &fp: , 1111•11 . .ci.t ukii'llawa.us Mailing Address: 1) t 0 \ f'41 litet/ 1,2 tit ,1 Ayr. • City Name: \) Mailing Address: 1 3 ;-7 irti 59e 6 E-Mail Address: GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 'r Company Name: ( L./Y / Mailing Address: 1 7/ Wer g.534, Contact Person: E-Mail Address: Q:\Applicalions\Forms-Applicati�ns On LineO-2006 - Permit Application.doc Revised: 9-2006 bh c o (V\ Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. 1 7,9,f- 06D Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 6 ' 84 . i /2 1 › Site Address: )NE: 36 5c,t);\- \ Suite Number: 1;4:=k9 Floor: Tenant Name: New Tenant: c " - ErYes ..No Property Owners Name: 1,-Le 1 7 . 17)'-c CI f,erX'' 4 C State (For office use only) - itC Mozb CO( P(03 OVp Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Day Telephone lc 3,21 6:37 e") . City State Zip r 1-7-(-0,"--)Fax Number: /C' Mailing Address: City State Zip Contact Person: Day Telephone: E-Mail Address: Fax Number: Contractor Registration Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Ay-c .A., Contact Person: Day Telephone: g) t7"— State E-Mail Address: Fax Number: 9/ 7 63 5 - ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: (), * '(1" 4550c i-4-es Cc n5ui7 Mailing Address: 630e W, S keLktree rA41 City Day Telephone: Fax Number: tO 0 ft .1 .954 g Zip - 5L4 q5a, 7(16- tug/ Page 1 of 6 ING PERMIT INNFORII 'ION = 20 -3674 Valuation of Project (contractor's bid price): $ 1 Scope of Work (please provide detailed information): 1—y-■ 5 1-0,1 l Q: Applications\Fomts- Applications On Line\3 -2006 - Permit Applicetion.doc Revised: 9 - 2006 bh Existing Building Valuation: $ n r, n- .S'firvt+ c1tvre., I 9 ex 4 Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan sub .'ttal will be required. 1s Floor 2"" Floor 3rd Flogr Floors - Basement Accessory Structure* Attached Garage Detached Garage Attaclied Carport Detacliei Covered Deck Uncovered Deck *For an Accessory dwelling, Lot Area (sq ft): *Provide docum Number of Parking S : s Will there be a ch in Provide All wilding Areas Square footage i eiow sting; Provided: Standard: use? ❑ Yes : .Interior Remodel i TION/RAZARDOUS MATERIALS: Add tion:to . . :Existing Structure vide the following: Floor area of principal dwelling: tion that shows that the principal owner lives in one of the dwellings Type`o f Construbtion per .. IBC 116 Floor area of accessory dwelling: or her primary residence. Compact: Handicap: Type Hof , pceupancy.;pet IBC PLANNING DIVISION: Single family building footprint ., - a of the foundation of all structures, plus any decks ove 8 inches and overhangs greater than 18 inches) If "yes ", explain: FIRE PRO prinklers ❑ Automatic Fire Alarm ❑ .......None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Sa Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Page 2 of 6 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Ventilation Fan Connected to Single Duct 1 Diffuser Thermostat id, r 1 O�• 3 -15 HP /500,000 BTU Floor Fumace 15 -30 HP /1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System ® Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Va.V - by x 2 S 2 asi 1$OD L rA • Ea C Imo`. Air Handling Unit <10,000 CFM Incinerator - Comm/Ind • MECHANICAL PERMIT INFORMATION — 206 -431 -3670 MECHANICAL CONTRA OR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Mechanical work (contractor's bid price): $ \721000 Scope of work (please a rovide detailed information): r I Q:\ Applications\For ms- Applications On Line13 -2006 - Pemtit Applicaiion.doc Revised: 9 -2006 bh Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New ... X Replacement .... ❑ Indicate type of mechanical work being installed and the quantity below: V 1-o \N. •2a Mr et c...77_5 Fuel Type: Electric ❑ Gas Other: Page 4 of 6 Fixture Type: Qty tFlxtbre Type: °. , . ..Qty :Fixture;Type: '.. Qty ' 'Fiatpre Type: Qty Bathtub or combination bath/shower Drinking founta' . a r water cooler (per he Wash fountain Gas piping outlets Bidet Food -waste t. ∎der, commerci.. Receptor, indirect waste Clothes washer, domestic Floor d •.: / +., inks Dental unit, cuspidor Sho ; , single head trap t als Dishwasher, domestic, with independent drain Lav try If Wa:: Closet J Building sewer or trailer park sewer ain water system — per drain (inside building) Water k rater and /or vent / Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and /or water treating equipment A Repair or .',, • ration of drainage l', vent piping ' Medical gas piping system serving one to five inlets/outlets for specific gas PLUMBING AND GAS PPIPING CONTRACTOR INFORMATION Company Name: 1 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing w Valuation of Gas Piping wo Scope of Work (please provid Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Indicate type of plumbing fixtures and/or gas piping o Q :1ApplicatiomlFor n - Applicanons On Lmel3 -2006 - Pamit Application.doc Revised 9-2006 bh being installed and the quantity below: S tith Zip k (contractor's bid price): $ S 00 (contractor's bid price): $ fled ormation): *Mr eAf ' Sewer: Page 5 of 6 Date Application Accepted: n 0- gl Date Application Expires: Staff Initials: I PERMIT APPLICATION NOTES _ Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORI D AG>rNT: Signature: Print Name: Mailing Address: ;� ✓ .-' C'* 2 Tt Q:1ApplicationsTorms- Applications On Line13 -2006 - Permit Application.doc Revised: 9 -2006 bh Date: Day Telephone: 2i �' t . X 1.) -ra�t fDr - ( S cj City State f) Page 6 of 6 Receipt No.: R08 -01725 MECHANICAL - NONRES Payee: CONSTRUCTIVE BLDG SERVICES ACCOUNT ITEM LIST: Description City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -061 Address: 2636 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/03/2008 Applicant: FYE Issue Date: Initials: WER Payment Date: 05/20/2008 10:21 AM User ID: 1655 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7747 253.00 Account Code Current Pmts 000.322.102.00.0 253.00 Total: $253.00 Payment Amount: $253.00 2646 05/20 9711 TOTAL 1222.50 doc: Receipt -06 Printed: 05-20 -2008 RECEIPT NO: R08 -00594 Initials: JEM User ID: 1165 Payee: EXPRESS PERMITS SET ID: S000000972 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us D08 -115 520.65 EL08 -204 98.40 M0.8_0.6ii - 63.25 PG08. -066 32.00 TOTAL: 714.30 ACCOUNT ITEM LIST: Description ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES SET RECEIPT • Payment Date: 03/03/2008 Total Payment: 714.30 TRANSACTION LIST: Type Method Description Amount Payment Check 11076 714.30 TOTAL: 714.30 Account Code Current Pmts 000.345.832.00.0 98.40 000/345.830 615.90 TOTAL: 714.30 8 T710 TOTAL 714 30 Project: ic y6 Type of Inspection 31a,/ Address: 26 40.21/ Date Called: Special Instructions: Date Wanted: a /d g' a.m. p.m. Requester: Phone No: y INSPECTION NO. INSPECTION RECORD Retain a copy with permit tilDg -ob1 PIERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ct 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 $60.0A1NSPECTION FEE REQUIRED. Prior to inspection, fee must be paid it 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: teic Date: 7 4 5 Receipt No.: 'Date: COMMENTS: 110. J . � t e rs�,f f / S /�T 4-1 [ / � 1 I V411 1 -- . 015'2- 2634 `YG- Pa44114. ye-5 V4-1/Z . Y Pei. F 2 ad w yv 1(4, , , , 8 a.m. p.m. Requester: Phone No: 4 d tuP'7 z 5 1 Project: Type of Ins tign: 4 eG ar e ocar oc. Address; 1 36 1 �I Date Called: Special Instructions: Date Wanted: 4 D a.m. p.m. Requester: Phone No: 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. Inspector: INSPECTION RECORD Retain a copy with permit /I 5' PERMIT NO. (206)431 -3670 Corrections required prior to approval. !Date: 7 /2z- , El $60.00 aNSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: IDate: Project: 9c Type o ,pe� t'o k Address :, _ nM // Date Called: Special Instructions: Date nted: v 7 - 6/6-d a r P.m: Requ ster: Phone 2S - - _323 3 Approved per applicable codes. INSPECTION RECORD Retain a copy with permit PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Corrections required prior to approval. COMMENTS: Date: I Inspecto ___ r: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 Receipt No.: 'Date: COMMENTS: /. 5e;544 ; ► t64I/'s 7 , 14J1 v,' ina etd ,' 1 os 4 /.o 3 fal no al a ; of s e A Li ,r,! pif ft. Tkiit ! Special Instructions: • Date Wa nted �� 7 d p.m. Requester: Project. f" e- Typesof Inspection: /2d) /7 - 1 4 Address: .263 / Date Called: Special Instructions: • Date Wa nted �� 7 d p.m. Requester: Phone No Z.5 Zi :3 Z / / 9-7 4v -19 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Approved per applicable codes. tz Corrections required prior to approval. Date: 4 z7 n $60.0 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: 'Receipt No.: 'Date: Proj"P Type oInspection; _ //v Add s:/ 36 4 /( _2- Date Called: Special Instructions: Date Want / ' Q � am , [ /. p Requester: Phone 12- _ - 2`7 -7Z.g& 1 / L8 -6 6( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 11� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: t eA 6 of 5411 46,, lbw/ G'v� 1 Date_ / � e Inspector: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ti Project: 4 Sprinklers: Y Type of Inspe ion: egr 'rirt , 2 t 4A L\ te- - Address: , a( 0 5 Suite #: S. c . ,'4-L.. L Contact Person. Pre -Fire: /0 Special Instructions: Phone No.: Needs Shift Inspection: . Y Sprinklers: Y Fire Alarm: Y Hood & Duct: 0 Monitor: (- „Arwct, Pre -Fire: /0 Permits: ;Occupancy Type: /vim INSPECTION NUMBER • CITY OF TUKWILA FIRE DEPARTMENT - s r Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 INSPECTION RECORD Retain a copy with permit Q3” j1 7 tb ∎ — I PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Corrections required prior to approval. COMMENTS: Inspector: f - \ / y Date: 7 f 0 3/ g Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department: CaII to schedule a reinspection. T.F.D. Form F.P. 113 ` _ Project: ` `T 6_7: . Sprinklers: Fire Alarm: Type If Inspection: S P N G cl.. . \ ai (, Address: (:, 3 Co Suite #: • 6_ M cq-2,L Contact Person:" Special Instructions: Phone No.: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER Approved per applicable codes. INSPECTION RECORD Retain a copy with permit Word /Inspection Record Form.Doc 1/13/06 CITY OF TUKWILA FIRE DEPARTMENT j t o5 - C� I F — /1 5' 0? -- - Pd 7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 rrections required prior to approval. COMMENTS: e c, --- --o l c- c_crito i . - p 1n Inspector: Date: 9 /oft' rs .. $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 ACTIVITY NUMBER: M08 -061 DATE: 03 -03 -08 PROJECT NAME: FYE SITE ADDRESS: 2636 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued ■ DEPARTMENTS: Building I ►ivi Ion (./ it-00 Public Works Complete Fvf Comments: n TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28 -02 'PERMIT COORD COPY 110 PLAN REVIEW /ROUTING SLIP 1 AV & 5 - t Fi re Prevention Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Planning Division Permit Coordinator n DUE DATE: 03-04-08 Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: No further Review Required DATE: Not Applicable Not Approved (attach comments) DATE: n DUE DATE: 04 -01-08 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License CONSTBS994D8 Licensee Name CONSTRUCTIVE BLDG SERVICES INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602003542 Ind. Ins. Account Id 0 Business Type CORPORATION Address 1 3937 39TH AVE Address 2 City OAK LAND County OUT OF STATE State CA Zip 946192201 Phone 5105311175 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 5/15/2001 Expiration Date 5/20/2010 Suspend Date Separation Date Parent Company Previous License CUMMIC *066DB Next License Associated License Business Owner Information Name Role Effective Date Expiration Date CUMMINGS, JEFFERSON D PRESIDENT 03/28/2001 HOWARD, JEFFREY W SECRETARY 03/28/2001 Look Up a Contractor, Electric or Plumber License Detail • Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Bond Information Bond # 2 Bond Company Name DEVELOPERS SURETY & INDEM CO Bond Account Number 846283C Effective Date 03/06/2002 Expiration Date Until Cancelled Cancel Date Impaired Date Bond Amount $12,000.00 Received Date 12/28/2001 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= CONSTBS994D8 05/20/2008 Key to Divisions of Work F FURNISHED I INSTAUED CSI C CSI SHEET DESCRIPTION /NOTES u OlaNv1 TENANT TENANT'S CONTRACTOR 1 QIOlaNvi TENANT TENANT'S '=ONTRACTOR 1 ONf1SJX3 00 CONTRACT REQUIREMENTS 1 Bonds(if required) 0 00600 T T -1 P Payment/Performance Bond shall 0 0 01 GENERAL 1 Permits and Fees 0 01000 1 1 �IIL� Per Scope of Work 0 0 000 02 SITE WORK 1 Selective Demolition 0 02070 A A - 1 F For Rear Egress Door 0 0 0 0 03 CONCRETE 1 Concrete slab A A-1 0 0 04 MASONRY 1 Reserved 05 METALS 1 Misc. Metals 0 05000 A A -1 S See Technical Specification on N -1 2 Light Gauge Framing 0 05400 A A1,N1 S See Partition Schedule Sheet A -1 0 0 3 Metal Furring Channels 0 05000 A A -1 I If Required 0 0 4 3/4 "x3/4" Wall Angle 0 05000 A A -2 S Slatwall Trim,See Detail Sheet A -4 5 1 "x1" Wall Angle 0 05000 A A -1 S Sales Area Columns 6 Metal U– Channel 0 05000 A A -1.1 S Storefront to WOOD AND PLASTICS - 1 Rough Carpentry 0 06100 A A -1 S See Technical Specification on N -1 0 0 2 Finish Carpentry 0 06200 A A -1 S See Technical Specification on N -1 0 0 3 Toggle Bolts 0 06200 A A -1 S See Technical Specification on N -1 0 0 4 Misc. Wood Trim 0 06220 A A -2 0 0 i/A 5 Particle Board Valance 0 06220 6 Plastic Laminate 0 06240 A A2,F1 • • Fixtures 0 0 7 Hardboard Panels 0 06255 A A - 2 P Prefinished (Slatwall) 07 THERMAL/MOISTURE I 4 O O 0 l0 0 0 li C C 0 00 00 00 0 s� Material Symbol Ic ey I1I1I1I ICI • ^ ' 4 SWUM 1 Symbol Key MUSIC ACOUSTICAL CEILING CONCRETE BATT /LOOSE INSULATION STEEL FINISHED WOOD GYPSUM WALLBOARD BLOCKING /ROUGH LUMBER RIGID INSULATION ' I PLYWOOD GLASS PARTICLE BOARD CSI SPECIFICATION DIVISION NUMBER ITEM, NOTE OR LINE NUMBER ELEVATION KEY NUMBER SHEET NUMBER DETAIL OR SECTION KEY NUMBER SHEET NUMBER KEY TO WALL & FASCIA FINISH SCHEDULE EY TO FLOOR FINISH SCHEDULE \ u / + KEY TO CEILING & SOFFIT FINISH SCHEDULE KEY TO WALLS AND PARTITION SCHEDULE Fire Ratings CARPET MIWKEN MODULAR – TONAL VISTAS CLASS "1" RATING CRITICAL RADIANT FLUX– ASTM TEST E-648 : : W /CM OPTICAL DENSITY OF SMOKE– ASTM TEST E -66 150 FLAMING WALL PARTITIONS SALES TO STOCKROOM: NEW NON –RATED PARTITION TENANT TO TENANT: 1 HOUR RATED PAR11110N TO ABOVE CEILING; PER UL #U-465 TENANT TO SERVICE CORRIDOR: 1 HOUR RATED PAR11110N TO DECK; PER UL LJ -465 CEILING SYSTEM CEILING SYSTEM: CLASS "A" FINISHES SLATWALL CLASS "C" PLASTIC LAMINATE: CLASS "C" MOUNTED TO CLASS "A" VINYL COMPOSITE TILE: CLASS "1" VINYL COVE BASE: CLASS "1" FLOOR 11LE: CLASS "1" Copyright These drawings shall remain the exclusive property of THE ARCHITECT and its Consultants. All rights and privileges are reserved by the design team. The designer's liability is limited to the extent of their fee. These drawings shall not be duplicated without prior written permission of The Architect. Schedule of Drawings T -1 TITLE SHEET T -2 EGRESS PLAN A -1 ARCHITECTURAL FLOOR PLAN / PARTITION & DOOR SCHEDULES A -1.1 STOREFRONT ASSEMBLY / MISC. DETAILS A -1.2 STOREFRONT ELEVATION / FLOORING PLAN A -2 INTERIOR ELEVATIONS / FINISH SCHEDULES A -3 REFLECTED CEILING PLAN / LIGHT FIXTURE SCHEDULE A -4 MISCELLANEOUS DETAILS F -1 FIXTURE PLAN N -1 NOTES AND SPECIFICATIONS P -1 PLUMBING PLAN AND SPECIFICATIONS M -1 MECHANICAL PLAN M -2 SPRINKLER PLAN M -3 MECHANICAL SPECIFICATIONS E -1 ELECTRICAL LIGHTING PLAN E-2 ELECTRICAL POWER PLAN E -3 ELECTRICAL SPECIFICATIONS & SCHEDULES Store Data (FOR STORE USE ONLY) AREA DISTRIBUTION PLAN DESIGNATION QUANTITY PERCENTAGE OF AREA 1. GROSS LEASED AREA 3,631 S.F. 100.0 % 2. SALES AREA 3,142 S.F. 86.5 % 3. STOCKROOM 545 a S.F. 9.5 % 4. TOILET ROOM 62' S.F. 1.7 % 5. EGRESS CORRIDOR 82 S.F. 2.3 % NORDSTROM SEARS Key Plan N.T.S.. CODE ANALYSIS: USE GROUP: CONSTRUCTION TYPE: SEISMIC ZONE: FIRE SUPPRESSION: LIVE LOAD: M ACY' S MOVIES SCOPE OF WORK: THIS PROJECT IS A NON– STRUCTURAL TENANT FIT UP OF AN NEW SPACE WITHIN WESTFIELD SOUTH CENTER. WORK SHALL INCLUDE THE CONSTRUC110N OF NEW INTERIOR PARTITIONS, DOORS; CEILINGS, IJGHIING, AND THE INSTALLATION OF ALL RELATED FIXTURES AND FINISHES. NEW HVAC SYSTEM AND ACCESSIBLE TOILET ROOM ARE REQUIRED. SEE DRAWINGS FOR ADDITIONAL INFORMATION. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES AS NOTED ON THIS DRAWING. Project Information APPLICABLE AND MODEL CODES: International Building Code 2006* National Electrical Code 2005* International Mechanical Code 2006* Uniform Plumbing Code 2006 International Fire Code 2006* ANSI -117 -1 2003* ADA Guidelines * with the WA State Building Codes Amendments And all accumulative supplements thereof WA State Energy Code BUILDING DEPARTMENT: City of Tukwila Department of Community Development Contact: Dave Larson Phone: (206) 431 -3678 6300 South Center Blvd #100 Fax: (206) 431 -3665 Tukwila, WA 98188 MEANS OF EGRESS /OCCUPANCY LOAD SEE SHEET T -2 FOR ADDITIONAL INFORMATION 1 L— f NOTE: SPRINKLER AND FIRE ALARM WORK TO BE PERFORMED UNDER SEPARATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPARATELY. NOTE: MAXIMUM NUMBER OF EMPLOYEES ON SITE AT ANY ONE TIME IS 4. SPACE IS LOCATED WITHIN 300 FT OF PUBLIC ACCESSIBLE RESTROOMS. JCPENNEY f.y.e. SPACE # 2110 LEVEL 2 OF 3 3,631 SQ. FT. o o w M – MERCANTILE 2B UNPROTECTED,NON– COMBUSTIBLE, FULLY SPRINKLERED CLASS D AUTOMATIC SPRINKLER SYSTEM 100 PSF C.y of Tu BUILDING DIVISION SEPARATE PERMIT FOR 0 d Plumbic li Gas Piping City of Tukwila puit.p!NG DIVISION COOS COMP , Filar review approva wan Approval Df i�C119yyy'��`��11Ix:1f 411 ner b does ! a theviolati . , vf / �r :f . mil a lld �S l f_ _ ��. 01 � 41. - i B I /1 a: 000 REVISIONS No � w shall b T made to the scope Tukwila Building Di�visiion. of NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Southcenter Mall Space # 2110 2636 Southcenter Mall Seattle, WA 98188 CITY OF N . F J O q '/ O8 P=i' ti;1 Contract Requirements 00002 — PROJECT DIRECTORY LANDLOP F'S REP westfield Corporation Inc. Contact: Josh Kimmel 11601 Wilshire Blvd 12th Floor Los Angeles, CA 90025 TENANT: Trans World Entertainment Corp. Contact: Allison Rivers 38 Corporate Circle Albany, NY 12203 TENANT'S COORDI Bay Planning Company, Inc. Contact: David M. Sorgman 25 Mathewson Drive, Suite 200 Weymouth, MA 02189 SUBCONTRACTOR: Subcontractors are those individuals and /or Companies providing services, products and portions of the Work, described in the technical drawings and specifications, under direct contract to the Tenant's Contractor. Requirements 01000 - GENERAL R E S E N T A T I V E: Phone: (310) 893 -4761 FAX: (310) 575 -5991 Phone: (518) 452-1242, Ext. 7489 FAX: (518 ) 452 -0511 NATOR: Phone: (781) 331 -4000 FAX: (781) 335 -2115 The Tenant's Contractor and all Subcontractors shall perform their Work according to the following: EXISTING CONDITIONS A. Prior to submitting bid proposals, the Tenant's Contractor and each Subcontractor shall visit the proposed space and make themselves familiar with all existing conditions, take field measurements and record all information neped to provide a complete scope of Work. B. Notify the Tenant immediately of conditions whi::n may contribute to unnecesscr - j, excessive costs C. No additional cc' npensation will be paid ty the Tenant . for disputes ..;hich result from c lack of far+iliarity with the existing conditions. 0103 — MODIFICATION PROCEDURES S'JBSTITUTIONS & CHANGES J. DO NOT substitute materials, equipment or methods unless such substitution has been approved specifically 'in writing by the Tenant. E. Notify the Tenant immediately by telephone of any hidden, unforeseen conditions and any requirements imposed by the Landlord which impact the Work. Confirm all notifications and action required in writing within 24 hours of the event. F. Milestone date changes must be made in writing by Tenant. 01040 — COORDINATION G. The Tenant's Contractor and each Subcontractor shall be thoroughly familiar with the Work shown on the drawings and on the other Contract Documents. H. Each Subcontractor shall coordinate their Work with that of others and be aware of all Related Work to be performed by others, via the Tenant's Contractor. 01060 -- REGULATORY REQUIREMENTS 1. Comply with all applicable National, State and Local codes. See Project Information on this sheet. 01100 -- SPECIAL REQUIREMENTS J. NEW STORE CONSTRUCTION K. WRITTEN DAILY JOURNAL shall be maintained L TELEPHONE shall be provided on site by Tenant's Contractor. M. DESIGNATE A SUPERINTENDENT for the duration of the Project and submit his/her name to the Tenant. N. Work shall be completed in a timely manner, consistent with the approved CONSTRUCTION SCHEDULE. P. The Tenant's Contractor shall be responsible for receiving and maintaining in good condition all millwork, fixtures and equipment up to the Date of Substantial Completion. Q. All Tenant material delivered to the Project shall be checked against the Tenant's material list by the Tenant's Contractor at the time of delivery. All discrepancies shall be noted in the Receiving Report and in the Daily Journal, and the Tenant's Contractor shall immediately notify the Tenant of same. All Shortages occurring after receipt of goods shall be charged back to the Tenant's Contractor. R.CLEANING: a. Each Subcontractor shall clean his /her Work and remove all trash, debris, packing, etc... resulting from that Work. b. Final cleaning shall be done by a professional cleaner. See specification section 01710 – FINAL CLEANING 01340 — SUBMITTALS S. Product samples, manufacturer's data and shop drawings shall be submitted to Comprehensive Development Corp. for review prior to fabrication or start of work. 01700 — CONTRACT CLOSE —OUT T. Substantial Completion is the date certified by Tenant's Project Manager on which the Work or designated portion thereof is sufficiently complete so the Tenant may occupy the same for the intended purpose. U. Provide the following for close –out: 1 –Daily Journal 2– Operation and Maintenance Data 3 –Keys 4 –Spare Parts, Materials and Stock 5– Certificate of Inspection /Occupancy 6– Certificate of Insurance 7– Evidence of Payment and Release of Liens 8 –List of Subcontractors, Vendors and Suppliers 9 –Final Statement of Account V. Construction codes and keys must be turned into TWEC with the General Contractor's final payment request or the contractor will be charged $70. ff o*Z-le1 NOTE: T.G.C. TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND INFORM THE TENANT'S PROJECT MANAGER AND THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. NOTE: T.G.C. TO FIELD VERIFY CONDITION OF ALL ITEMS DESIGNATED TO REMAIN OR BE REUSED AND INFORM TENANT'S PROJECT MANAGER AT THE START OF' CONSTRUCTION OF ANY ITEMS IN NEED OF REPAIR. 1 1 o isti "it 1Y1Y1 Imo M CO P 0 N al f s SHEET NUMBER T -1 SHEET 1 OF 17 �V� DATE: 212010e JOB NO: Pr-06-01-D TITLE SHEET STORE NO: 1248 CHECKED: CM Fax: 781-335-2115 HVAC SYMBOL LEGEND DRAWING SYMBOL DESCRIPTION MODEL CEILING DIFFUSER – TYPE– RUNOUT AND PRIMARY AIR HEATING CFM A –XX NECK SIZE 300 CFM N.C. UNIT WEIGHT (LBS) RETURN/EXHAUST – TYPE –SIZE MIN. CFM EXT. S.P. (IN. W.C.) C – XX 180 GRILLE EGISTER CFM VOLTAGE VAV -1 BRANCH DUCT SPIN –IN FITTING i _L 1 –C4 ROUND ELBOW 550 TRANSITION / L.Q 113 1/S MANUAL VOLUME DAMPER 5.0 5.0 �1 FLEXIBLE DUCTWORK – 5' -0" MAX. L REVISION TRIANGLE 115 VAV -2 POINT OF CONNECTION NEW TO EXISTING QT THERMOSTAT �-� RETURN /EXHAUST AIR — — — -- EXISTING HVAC 0.05 NEW DUCTWORK 27 0 KEY NOTE PARALLEL FAN POWERED V.A.V. BOX (WITH ELECTRIC HEATING COIL) SCHEDULE UNIT NO. MANUF. MODEL PRIMARY AIR INLET SIZE (IN.) PRIMARY AIR HEATING CFM FAN MOTOR DATA HEATING COIL DATA MAX. ALLOWED S.P. DROP (IN. W.C.) * DOWNSTREAM TOTAL S.P. IN. W.C. N.C. UNIT WEIGHT (LBS) MAX. CFM MIN. CFM EXT. S.P. (IN. W.C.) FAN H.P. VOLTAGE CAPACITY (KW) VOLTAGE VAV -1 TRANE VPEF12 12" DIA. 1800 550 1100 0.5 0.5 113 1/S 27711160 277/1 Ari 5.0 5.0 480/3/60 0.05 0.5 27 115 VAV -2 TRANE VPEF12 1 2 " DIA. 1800 550 1100 480 [3 /0 0.05 0.5 27 115 * – THIS INCLUDES THE LOSS FOR THE VAV BOX AND THE HEATING COIL OUTSIDE AIR NOTE: THIS TENANT HAS NO CONTROL OVER THE AMOUNT OR PROPORTION OF OUTSIDE AIR DELIVERED TO THIS LEASED SPACE. ALL OUTSIDE AIR FOR THIS SYSTEM IS SUPPLIED BY THE LANDLORD'S CENTRAL VAV SYSTEM. AS SUCH, rr 15 THE LANDLORD'S SOLE RESPONSIBILRY TO ENSURE THE CODE– REQUIRED MINIMUM OUTSIDE AIR IS DELIVERED TO THE TENANT'S SPACE DURING NORMAL MALL HOURS OF OPERATION. SCHEDULE OF DIFFUSERS, REGISTERS AND GRILLES UNIT NO. MANUFACTURER MODEL SIZE OF DIFFUSER NOTES A TITUS TMS 24" X 24" 1 B TITUS 50F 24" X 24" 2 C TITUS 50F 24" X 12" 2 NOTES: 1. SUPPLY AIR DIFFUSER WITH OPPOSED BLADE DAMPER. 2. 1/2" X 1/2" X 1/2" EGGCRATE RETURN AIR GRILLE. (12. J 6 ; VAV -1 ANCHOR TO STEEL BEAM OR TOP CHORD OF BAR JOIST AT PIN POINT (TYP) 1/2" ROD (TYPICAL) PRIMARY SUPPLY AIR DUCT TRANSVERSE RESTRAINTS (TYP OF 4) 45' NQTE: PROVIDE LONGITUDINAL AND TRANSVERSE RESTRAINTS TO COMPLY WITH 2006 IBC REQUIREMENTS FOR SEISMIC ZONE 'D'. N.T.S. MOUNTING DETAIL LONGITUDINAL RESTRAINTS (TYP OF 4) LONGITUDINAL RESTRAINTS (TYP OF 4) MD021 1 L -T SPRING VIBRATION ISOLATORS (TYPICAL) VAV BOX FLEX DUCT CONNECTION (TYPICAL) INSTALL B22 STRUT EACH SIDE MECHANICAL KEY NOTES 1. NEW VAV BOX. PROVIDE MINIMUM 4 EQUIVALENT DIAMETERS OF STRAIGHT DUCT IMMEDIATELY UPSTREAM OF VAV BOX. MEDIUM PRESSURE DUCT UPSTREAM OF VAV BOX TO BE "PITTSBURGH LOCK" AND CONSTRUCTED TO 6" PRESSURE CLASSIFICATION PER SMACNA. 2. LOCATE VAV BOX IN BEST POSSIBLE LOCATION. LOCATION ON DRAWING IS APPROXIMATE ONLY. ABIDE BY MANUFACTURER'S CLEARANCE RECOMMENDATIONS. HANG FROM STRUCTURE ABOVE WITH VIBRATION ISOLATORS. 3. EXTEND AND CONNECT NEW SUPPLY AIR DUCTWORK OF SAME SIZE TO EXISTING LANDLORD SUPPLY AIR DUCTWORK. VERIFY EXACT LOCATION, SIZE AND ELEVATION IN FIELD. 4. T –STAT – MOUNT AT 4' -6" A.F.F. 5. RETURN AIR TO EXIT SPACE THROUGH 6" OPENING ABOVE DEMISING WALLS 6. SEE PLUMBING PLAN AND RISER DIAGRAMS ON SHEET M -2 FOR PLUMBING WORK IN THIS AREA. 7. FAN /LIGHT COMBINATION WITH INTEGRAL BACKDRAFT DAMPER BY ELECTRICAL CONTRACTOR. DUCTWORK BY MECHANICAL CONTRACTOR. 100 CFM. 8. EXTEND 6 "0 EXHAUST DUCT AND CONNECT TO LANDLORD'S TOILET EXHAUST MAIN. COORDINATE ROUTING WITH LANDLORD'S REPRESENTATIVE. 9. LANDLORD'S EXISTING TOILET EXHAUST DUCTWORK TO REMAIN. 10. LANDLORD'S EXISTING SUPPLY AIR DUCTWORK TO REMAIN. 11 PER 2006 IMC SECTION 606 Install smoke detector to shut down air distribution by VAV's when the total combined C F M of all VAV's (to include other tenants) sharing the same plenum space exceeds 2000 CFM. (See IMC 606.2.2 for approved method of detection ANCHOR TO SIttL BEAM OR TOP CHORD OF BAR JOIST AT PIN POINT MAX. LENGTH 9' -4" ALL CHANNEL STRUTS AND ATTACHMENTS BY B–UNE OR APPROVED EQUAL PROVIDE TRANSVERSE BRACING OF DUCTWORK GREATER THAN 728 SQ. IN. 0 20' -0" O.C. AND LONGITUDINAL BRACING 0 40' -0" O.C. TWO HOLE OPEN ANGLE 3 SUSPENDED DUCTWORK DETAIL M 1 N.T.S. M405 HVAC CONTROLS THERMOSTAT HONEYWELL 7350D WfrH TG511 VERSAGUARD CLEAR LOCKING COVER, OR APPROVED EQUAL, 7 –DAY PROGRAMMABLE MULTI –STAGE HEATING /COOLING AUTOMATIC CHANGEOVER THERMOSTAT WITH NIGHT SETBACK CAPABILITIES TO CONTROL THE OPERATION OF EACH UNff. THERMOSTAT TO HAVE INTEGRAL TEMPERATURE DEADBAND AND START OPTIMIZATION. MOUNT THERMOSTAT AT 4' -6" A.F.F. SEQUENCE OF OPERATION PARALLEL TYPE FAN – POWERED VARIABLE AIR VOLUME SYSTEM, COOLING WITH ELECTRIC HEAT: COOLING CYCLE – OCCUPIED HOURS: THE THERMOSTAT SHALL MODULATE THE VARIABLE AIR VOLUME CONTROL DAMPER BETWEEN MINIMUM AND MAXIMUM POSITIONS AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE OCCUPIED COOLING SETPOINT OF THE THERMOSTAT. THE FAN SHALL BE DE– ENERGIZED. HEATING CYCLE – OCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE OCCUPIED HEATING SETPOINT OF THE THERMOSTAT, AND WITH THE VARIABLE AIR VOLUME CONTROL DAMPER IN THE MINIMUM POSITION, THE FAN SHALL OPERATE AND THE ELECTRIC HEATING COIL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. COOLING CYCLE – UNOCCUPIED HOURS: THE VARIABLE AIR VOLUME CONTROL DAMPER SHALL BE CLOSED AND THE FAN SHALL BE DE– ENERGIZED. HEATING CYCLE – UNOCCUPIED HOURS: UPON A DROP IN SPACE TEMPERATURE BELOW THE UNOCCUPIED HEATING SETPOINT OF THE THERMOSTAT, AND WITH THE VARIABLE AIR VOLUME CONTROL DAMPER CLOSED, THE FAN AND THE ELECTRIC HEATING COL SHALL CYCLE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE AT THE THERMOSTAT SETPOINT. 1 MECHANICAL PLAN M -1 0 1 2 4 8 FEET ■ L A -10 320 1/4" = 1' -0" A -10 320 H 111 I IJ� R EVIEWED FOR — 1 CODE COMPLIANCE APPROVE: MAR - 7 2r L 13 'ILD f NOTE TO GENERAL CONTRACTOR: THE EQUIPMENT SPECIFIED FOR THIS PROJECT SHALL BE PURCHASED THROUGH A NATIONAL ACCOUNT WITH TRANE. GENERAL CONTRACTOR OR THEIR MECHANICAL SUB – CONTRACTOR SHALL CONTACT: TRANE NATIONAL ACCOUNTS SARAH MICEU (518) 785 -1315 X 1413 FOR ORDERING AND SHIPPING DETAILS WITHIN THE FIRST WEEK OF CONSTRUCTION. GENERAL MECHANICAL NOTES A. THESE DRAWINGS ARE SCHEMATIC IN CHARACTER AND MUST NOT BE SCALED. THE CONTRACTOR SHALL FIT THE WORK TO THE JOB, CAREFULLY INVESTIGATING THE STRUCTURAL ELECTRICAL, ARCHITECTURAL SPACES AND FINISH CONDITIONS AFFECTING THE WORK ACCORDINGLY AND FURNISHING NECESSARY BENDS, OFFSETS, AND FITTINGS, JUNCTIONS ETC., WHETHER OR NOT SPECIFICALLY SHOWN OR CALLED FOR, AND SEE THAT THERE ARE NO INTERFERENCES BETWEEN THIS WORK AND THE WORK OF ANY OTHER TRADE. B. THE CONTRACTOR FOR THIS DMSION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DMSIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL HIS SUBCONTRACTORS WITH ALL OTHER DMSIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL HIS SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. C. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS REQUIRED BY CODE. D. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURERS' INSTRUCTIONS, THE CONTRACT DOCUMENTS, AND APPUCABLE CODES AND REGULATIONS. E. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORK WITH ARCHITECTURAL, STRUCTURAL, CML, ELECTRICAL WORK, ETC., SHOWN OR SPECIFIED ON OTHER CONTRACT DOCUMENTS. F. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS THAT ARE NOT DIMENSIONED ARE APPROXIMATE ONLY. THE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS SHALL BE BASED UPON PROJECT SITE CONDITIONS. DO NOT SCALE DRAWINGS. G. ALL EQUIPMENT, PIPING AND DUCTWORK NOT BEING USED OR SHOWN TO REMAIN SHALL BE FULLY REMOVED AND NOT ABANDONED IN PLACE. H. ALL EQUIPMENT, INSTALLATIONS AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE LANDLORD CRITERIA. I. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO THE LANDLORD'S BASE BUILDING SYSTEMS AS APPUCABLE, AND FOR FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING STUB –INS, TAPS, ETC. FOR MECHANICAL SYSTEMS WITHIN TENANT'S SPACE. COORDINATE ALL SYSTEMS IN FIELD. J. NO FIBERGLASS DUCTBOARD ALLOWED. K. COORDINATE DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS, LIGHTING, AND OTHER CEILING ITEMS AND MAKE MINOR DUCT MODIFICATIONS AS NECESSARY. L BRANCH DUCT RUNOUTS TO DIFFUSERS SHALL BE SAME SIZE AS DIFFUSER NECK UNLESS SHOWN OTHERWISE. M. CONTRACTOR SHALL BALANCE ALL HVAC SYSTEMS PER SECTION 15950 IN THE MECHANICAL SPECIFICATIONS. N. ALL EQUIPMENT SUPPORT AND DUCTWORK BRACING SHALL COMPLY WITH 2006 IBC REQUIREMENTS FOR LATERAL AND VhKIICAL RESTRAINT IN SEISMIC ZONE 'D'. VERIFY ALL CONDITIONS I N FIELD co n tZ Z O CO cn ZZ W z Z =I-w U o -,C/ < z o U l 11 M In M wis ce 40 u. RECEIVEQ CITY OF TUKWILA MAR 0 3 7008 PERMIT CENTER SHEET NUMBER M -1 SHEET 12 OF 17 SPRINKLER SYMBOL LEGEND DRAWING SYMBOL OL DESCRIPTION SEMI — RECESSED HEAD • CONCEALED HEAD 0 PENDANT HEAD SPRINKLER KEY NOTES Q 1. PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME HEAD IN TOILET ROOM. ROUTE SPRINKLER PIPE ALONG FULL HEIGHT WALL SO AS NOT TO IMPEDE USE OF PLATFORM. 2. EXISTING LANDLORD SPRINKLER MAIN TO REMAIN. SHOWN FOR REFERENCE ONLY. VERIFY EXACT LOCATION AND HEIGHT IN FIELD. 3. INSTALL RECESSED TYPE SPRINKLER HEADS WITH POLISHED CHROME FINISH IN LAY —IN CEILING IN SALES AREA. 4. INSTALL PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME FINISH IN STOCK ROOM AND EGRESS CORRIDOR CEILING. 5. INSTALL PENDANT TYPE SPRINKLER HEAD WITH POUSHED CHROME FINISH IN LAY —IN CEIUNG TILE ABOVE TOILET ROOM PLATFORM. 6. INSTALL CONCEALED SPRINKLER HEADS WITH WHITE COVER IN GYP. BOARD CEIUNG AT STOREFRONT AND SOI H i s. D i VERIFY ALL CONDITIONS IN FIELD NOTE FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. l E ) • NOTE REFER TO ARCHITECTURAL REFLECTED CEILING PLAN TO COORDINATE EXACT LOCATION OF CEIUNG FIXTURES. IF DISCREPANCIES EXIST BETWEEN THIS SHEET AND ARCHITECTURAL REFLECTED CEILING PLAN, ARCHITECTURAL REFLECTED CEIUNG PLAN WILL TAKE PRECEDENCE. SPRINKLER HEAD LAYOUT IS FOR CONCEPT AND BIDDING PURPOSES ONLY. FIELD VERIFY TYPE AND LOCATION OF SPRINKLER HEADS. LANDLORD'S FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL LAYOUT, HYDRAULICALLY CALCULATED PIPE SIZES, ALL LOCAL CODES, AND LANDLORD'S CRITERIA AT TENANT CONTRACTOR'S EXPENSE. CONNECTION TO LANDLORD SPRINKLER SYSTEM MAIN PIPING SHALL BE SCHEDULED IN ADVANCE WITH LANDLORD'S FIELD REPRESENTATIVE. REFER TO ARCH. REFLECTED CEILING PLAN FOR CEILING HEIGHTS. SPRINKLER WORK TO BE PERFORMED BY LANDLORD DESIGNATED CONTRACTOR A THE TENANT'S CONTRACTOR'S EXPENSE. VERY IMPORTANT THE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED BY THE FIRE PROTECTION CONTRACTOR IN STRICT ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD, LANDLORD'S FIRE INSURANCE UNDERWRITER, AND ALL GOVERNMENTAL AGENCIES AND AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. • 0 H l 0 1 2 4 do 2i CODE APPROVEL• • City Of SPRINKLER PLAN 8 FEET 1/4" = 1' -0" SPRINKLER NOTES SPRINKLER HEADS IN GYPSUM BOARD CEILING IN SALES AREA TO BE CONCEALED TYPE. SPRINKLER HEADS IN LAY —IN CEILINGS IN SALES AREA TO BE SEMI— RECESSED TYPE AND CENTERED IN CEILING TILES WHEREVER POSSIBLE. SPRINKLER HEADS IN STOCK AREA AND TOILET ROOM CEILINGS TO BE PENDANT TYPE THERE IS AN EXISTING SPRINKLER SYSTEM AND HEAD LAYOUT WITHIN THE TENANT PREMISES. LANDLORD'S SPRINKLER CONTRACTOR IS RESPONSIBLE FOR DESIGN COORDINATION AND ANY REQUIRED MODIFICATIONS OF SPRINKLER SYSTEM TO FTT NEW CEILING LAYOUT AND TO AVOID CONFLICT WITH OTHER TRADES. ALL SPRINKLER WORK IS TO BE PERFORMED BY LANDLORD'S SPRINKLER CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. COMBUSTIBLES SHALL NOT BE INTRODUCED UNTIL FULL SPRINKLER SYSTEM IS IN SERVICE. NO COMBUSTIBLES, INCLUDING FIRE— RETARDANT WOOD, SHALL BE INTRODUCED ABOVE THE TENANT'S ACOUSTICAL TILE CEIUNG. FIRE EXTINGUISHING DEVICES AS REQUIRED BY CODES, LOCAL AUTHORITIES, TENANTS INSURANCE CARRIER, AND LANDLORD'S INSURANCE CARRIER, SHALL BE FURNISHED AND INSTALLED AT TENANT CONTRACTOR'S EXPENSE. THE TENANTS GENERAL CONTRACTOR SHALL HAVE A FIRE EXTINGUISHER ON SITE AT ALL TIME DURING THE ENTIRE CONSTRUCTION PERIOD. IMPORTANT ALL FIRE PROTECTION SPRINKLER HEADS IN TENANT SPACE MUST BE QUICK RESPONSE (OR) TYPE. cv 41 O Z 0 ® gith dbigk 1=11E1 1 1 RECEIVE . CITY OF TUKALA MAR 0 3 2008 PERMIT CENTEP SHEET NUMBER M -2 SHEET 13 OF 17 X MECHANICAL SPECIFICATIONS 15000 - GENERAL PROVISIONS 0.01 DEFINITIONS: THE TERMS USTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DMSION 15 WORK AND ONLY DMSION 15 WORK. 1. WORK: LABOR AND MATERIALS OF THE CONTRACTOR AND /OR SUBCONTRACTOR. 2. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOBSITE IN NEW CONDITION AND GUARANTEE. 3. INSTALL: RECEIVE AT THE JOB -SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. 4. PROVIDE FURNISH AND INSTALL 5. CONNECT: BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENTS INCLUDING NECESSARY PIPE FITTINGS, DUCTWORK, TRANSITIONS, ETC. 6. CONCEALED: HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, ABOVE CEILING, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 7. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. 0.02 PERFORMANCE: MECHANICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.03 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIM NO EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDMONS. IF SITE CONDITIONS REQUIRE MODIFICATION OF THE SYSTEMS INDICATED IN THESE DOCUMENTS, SO ADVISE ENGINEER, AND IF ACCEPTED BY ENGINEER, INCLUDE COST OF SUCH MODIFICATIONS IN BID. 0.04 JOBSITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.05 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR A COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.06 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING, BONDING, AND INSURANCE, AND PERFORM OTT -TER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.07 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.08 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND ELECTRICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.09 CUTTING AND PATCHING: CUT AND PATCH AS REQUIRED. CUT OR WELD STRUCTURAL MEMBERS ONLY WITH APPROVAL OF STRUCTURAL ENGINEER. PATCHING SUBJECT TO APPROVAL BY ARCHITECT. 0.10 EXISTING FLOORS: TRENCH OR CORE BORE EXISTING FLOORS PER LANDLORD REQUIREMENTS. 0.11 ROOF PENETRATIONS: COORDINATE WFFH LANDLORD. 0.12 EQUIPMENT SUBSTITUTIONS: REIMBURSE ELECTRICAL CONTRACTOR, AT NO CHARGE TO TENAIV , FOR HIS COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.13 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.14 REFERENCE STANDARDS: COMPLY WITH APPUCABLE STANDARDS OF NFPA, ANSI, UL, ASHRAE, AND SMACNA, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.15 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF APPLICABLE CODES, LANDLORD, SERVING UTILITIES, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.16 MATERIALS AND EQUIPMENT: PROVIDE NEW UL USTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. 0.17 SHOP DRAWINGS: BEFORE ORDERING EQUIPMENT AND MATERIALS, SUBMIT NOT LESS THAN FIVE CERTIFIED COPIES OF ALL SHOP AND EQUIPMENT DRAWINGS FOR ENGINEER'S REVIEW, WHO WILL RETAIN TWO COPIES. ONLY FURNISH SYSTEMS AND EQUIPMENT IN COMPLIANCE WITH ACCEPTED SHOP DRAWINGS. 0.18 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' INSTRUCTIONS. 0.19 LAYOUT: INSTALL ALL PIPING AND DUCTWORK TO PRESENT A NEAT AND ORDERLY APPEARANCE. RUN ALL UNES PARALLEL WITH BUILDING CONSTRUCTION. MAINTAIN HEADROOM AND EQUIPMENT CLEARANCE, AND GRADIENT WHERE REQUIRED. ALLOW FOR EXPANSION AND CONTRACTION. 0.20 ACCESS DOORS: PROVIDE ACCESS DOORS OR PANELS FOR ALL VALVES, CLEANOUTS, DAMPERS, CONTROLS, DEVICES, AND OTHER ITEMS REQUIRING INSPECTION OR MAINTENANCE. ACCESS PANELS SERVING HVAC COMPONENTS SHALL BE 12- INCHES BY 12- INCHES MINIMUM OR LARGER TO PROVIDE SUFFICIENT WORKING CLEARANCE FOR COMPONENT BEING ACCESSED. 0.21 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT AND SUBMIT REPORT TO ENGINEER. 0.22 0 & M MANUALS: AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER OR OPERATOR. THE MANUAL SHALL INCLUDE BASIC DATA RELATING TO THE OPERATION AND MAINTENANCE OF HVAC SYSTEMS AND EQUIPMENT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED. WHERE APPLICABLE, HVAC CONTROLS INFORMATION SUCH AS DIAGRAMS, SCHEMATICS, CONTROL SEQUENCE DESCRIPTIONS, AND MAINTENANCE AND CALIBRATION INFORMATION SHALL BE INCLUDED. 0.23 WARRANTY: UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF FINAL ACCEPTANCE. DURING WARRANTY PERIOD, REPAIR OR REPLACE DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP WITHOUT COST TO TENANT. 0.24 EQUIPMENT IDENTIFICATION: IDENTIFY ALL APPUCABLE ROOFTOP EQUIPMENT WITH TENANT'S NAME AND SPACE NUMBER, USING 2" PAINTED CHARACTERS OR STAMPED METAL TAG. 0.25 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT, PIPE AND DUCT LOCATIONS TO AVOID CONFLICTS WITH OTHER CONSTRUCTION AND TRADES. 0.26 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.27 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.28 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS INCLUDED IN THESE SPECIFICATIONS MAY BE REQUIRED FOR THIS PROJECT. 0.29 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAING SUCH NO BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 0.30 AS -BUILT DRAWINGS: SUBMIT AS -BUILT DRAWINGS TO TENANT PRIOR TO FINAL APPUCATION FOR PAYMENT. 15200 - THERMAL AND ACOUSTIC INSULATION 2.10 VIBRATION ISOLATION: PROVIDE EFFECTIVE VIBRATION ISOLATION DEVICES, AND FLEXIBLE CONNECTIONS, FOR ALL MOVING MACHINERY. PROVIDE DEVICES IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE ASHRAE HANDBOOK, HVAC APPLICATIONS (LATEST EDITION), CHAPTER "SOUND AND VIBRATION CONTROL*. 2.20 NOISE TRANSMISSION: INSTALL PIPING AND DUCTWORK FREE FROM CONTACT WITH STRUCTURE OR EQUIPMENT TO PREVENT NOISE TRANSMISSION. 2.30 INSULATION REQUIREMENTS: INSULATE SYSTEMS AS SPECIFIED ONLY AFTER THEY HAVE BEEN TESTED AND INSPECTED. CLEAN ALL SURFACES THOROUGHLY OF MOISTURE, FOREIGN MATERIAL, GREASE, AND RUST. INSTALL INSULATION CONTINUOUS THROUGH PENETRATIONS. 2.31 INSULATION HAZARDS: USE ONLY INSULATION ADHESIVES, SEALERS, AND COATINGS WITH FIRE HAZARD RATING NOT TO EXCEED 25/50/50 FLAME SPREAD, FUEL CONTRIBUTED, AND SMOKE DEVELOPED, IN ACCORDANCE WITH UL 723 AND ASTM E84. 2.34 ACOUSTICALLY LINED SUPPLY DUCT: UNLESS OTHERWISE INDICATED ON THE PLANS, UNE SUPPLY DUCTWORK WITHIN 10 -FEET OF THE DISCHARGE AND INTAKE OF AIR HANDLING UNITS WITH 1" (MIN. R -4.2) THICK GLASS FIBER ACOUSTICAL DUCT LINER BOARD, OWENS- CORNING, OR EQUAL INCREASE DUCT SIZE INDICATED ON PLANS 2" EACH DIMENSION TO ACCOMMODATE DUCT LINER. MATERIALS SHALL HAVE A MOLD -, HUMIDITY -, AND CORROSION- RESISTANT SURFACE THAT MEETS THE REQUIREMENTS OF UL 181. 2.35 EXTERNALLY INSULATED SUPPLY DUCT: INSULATE SHEET METAL DUCTWORK WITH 2 -INCH FIBERGLASS BLANKET DUCT WRAP WITH AN INTEGRAL VAPOR BARRIER FACING, OWENS - CORNING, OR EQUAL THE INSULATION SHALL HAVE MINIMUM R = 3.0 HR- SQ.FT. DEG. F /BTU -IN. THERMAL RESISTANCE. DO NOT INSULATE PORTIONS OF DUCTWORK WHICH ARE INTERNALLY UNED. DO NOT INSULATE SUPPLY AIR DUCTWORK IN CONDITIONED SPACES UNLESS OTHERWISE INDICATED ON THE DRAWINGS (RETURN AIR PLENUMS ARE NOT TO BE CONSIDERED AS CONDITIONED SPACES). 2.36 INSULATED EXHAUST AIR DUCT: EXTERNALLY INSULATE WITH 2" THICK GLASS FIBER INSULATION WITH KRAFT FOIL VAPOR BARRIER, OWENS-CORNING, OR EQUAL. 2.40 INSULATED FLEXIBLE DUCT: GENERAL ENVIRONMENTAL CORPORATION TYPE G30A OR EQUAL, 5' -0" MAXIMUM LENGTH WITH A MINIMUM ELBOW RADIUS OF 1.5 X D AND A MINIMUM R = 6.0 HR SQ. FT.- DEG. F /BTU -IN. THERMAL RESISTANCE. USE ONLY FOR FINAL CONNECTIONS TO CEILING DIFFUSERS. DO NOT USE FOR V.A.V. BOX INLET CONNECTIONS. t ( 15300 - FIRE PROTECTION 3.10 WORK INCLUDED: PROVIDE ENGINEERED DESIGN UNLESS OTHERWISE REQUIRED BY THE LANDLORD OR THE AUTHORITY HAVING JURISDICTION. FURNISH, FABRICATE AND INSTALL ALL MATERIALS, AND SECURE ALL NECESSARY APPROVALS FOR A COMPLETE NEW FIRE PROTECTION SYSTEM THROUGHOUT THE ENTIRE SPACE. 3.15 INCLUDED ARE AUTOMATIC SPRINKLER SYSTEMS COMPLETE WITH PIPING, VALVES, HANGERS AND SUPPORTS, SPRINKLER HEADS, FLOW SWITCHES, SLEEVES, APPURTENANCES AND ACCESSORIES FOR A COMPLETE, OPERABLE AND APPROVED FIRE PROTECTION SYSTEM. 3.20 CODES AND STANDARDS: COMPLY WITH NFPA 13, OTHER APPLICABLE NFPA STANDARDS, le-;P ALL PERTINENT REQUIREMENTS OF FACTORY MUTUAL INSURANCE COMPANY, ALL LOCAL ANEW . � �;' STATE CODES AND ORDINANCES, AND THE FIRE MARSHALL HAVING JURISDICTION. 'f' 3.30 SYSTEM DESIGN: UNLESS OTHERWISE REQUIRED BY LANDLORD OR AUTHORITY HAVING JURISDICTION, THE SPRINKLER SYSTEM SHALL BE DESIGNED BASED ON THE INSTALLA OF A HYDRAUUCALLY CALCULATED SYSTEM. 3.40 SHOP DRAWINGS: PRIOR TO ANY MATERIALS BEING DELIVERED TO JOBSITE, SUBMIT COMPLETE SPRINKLER SYSTEM SHOP DRAWINGS AND HYDRAUUC CALCULATIONS TO LANDLORD'S REPRESENTATIVE AND AUTHORITY HAVING JURISDICTION. DO NOT BEGIN INSTALLATION OF SYSTEM UNTIL APPROVALS FROM 8011 PARTIES HAVE BEEN OBTAINED. 3.60 SPRINKLER HEADS: SEE SPRINKLER LEGEND AND SPRINKLER NOTES ON SHEET M -3. DO NOT INSTALL, OR RE- INSTALL, ANY SPRINKLER HEADS COVERED UNDER THE CENTRAL SPRINKLER COMPANY VOLUNTARY REPLACEMENT PROGRAM FOR 0 -RING SPRINKLERS. 3.70 INSTALLATION: SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED SHOP DRAWINGS, AND FLUSHED IN ACCORDANCE WITH NFPA STANDARDS. 3.80 TESTING: UPON COMPLETION OF INSTALLATION, TEST AND RE -TEST THE COMPLETE SYSTEM, MAKE ALL REQUIRED ADJUSTMENTS, AND SECURE APPROVAL OF LANDLORD AND AUTHORITY HAVING JURISDICTION. 15700 - AIR HANDUNG AND VENTILATION 7.71 VARIABLE AIR VOLUME PARALLEL FAN POWERED TERMINAL UNITS: TERMINALS SHALL BE CERTIFIED UNDER ARI STANDARD 880 -89 AND CARRY THE AR! SEAL THE UNIT SHALL BE TESTED AS A SINGLE UNIT INCLUDING MOTOR AND FAN ASSEMBLY, PRIMARY AIR DAMPER ASSEMBLY, WATER OR ELECTRIC HEATING COILS AND ACCESSORIES, AS SHIPPED. ALL ELECTRICAL COMPONENTS SHALL BE UL USTED AND INSTALLED IN ACCORDANCE WffH THE NEC. THE ENTIRE TERMINAL SHALL BE ETL OR UL USTED AS A COMPLETE ASSEMBLY. CASING SHALL BE MINIMUM 22 GAUGE GALVANIZED STEEL, INTERNALLY UNED WITH 1/2-INCH DUAL DENSITY GLASS FIBER INSULATION WHICH COMPUES WITH UL 181 AND NFPA 90A. ALL EXPOSED INSULATION EDGES SHALL BE COATED WFFH NFPA 90A APPROVED SEALANT. CASING SHALL HAVE BOTTOM ACCESS PANEL FAN SHALL BE CONSTRUCTED OF STEEL AND HAVE FORWARD CURVED DYNAMICALLY BALANCED WHEEL WITH DIRECT DRIVE MOTOR. MOTOR SHALL BE OF ENERGY EFFICIENT DESIGN, PERMANENT SPLIT CAPACITOR TYPE, WFFH INTEGRAL THERMAL OVERLOAD PROTECTION AND PERMANENTLY LUBRICATED BEARINGS, AND BE SPECIFICALLY DESIGNED FOR USE WITH AN SCR SPEED CONTROLLER. UNIT SHALL UTILIZE A MANUAL SCR FOR SPEED CONTROL WHICH SHALL INCORPORATE A MINIMUM VOLTAGE STOP. TERMINALS SHALL INCLUDE A GASKETED BACKDRAFT DAMPER AT THE FAN SECTION DISCHARGE. DAMPER SHALL BE HEAVY GAUGE STEEL WITH SHAFT ROTATING IN SELF - LUBRICATING BEARINGS. NYLON BEARINGS ARE NOT ACCEPTABLE. SHAFT SHALL BE CLEARLY MARKED ON THE END TO INDICATE DAMPER POSITION. REMOVABLE MARKINGS ARE NOT ACCEPTABLE. DAMPER SHALL HAVE MECHANICAL STOP TO PREVENT OVERSTROKING AND A SYNTHETIC SEAL TO MINIMIZE CLOSE -OFF LEAKAGE. ELECTRIC COILS SHALL BE UL US I WU, SUPPUED AND INSTALLED ON THE TERMINAL BY THE FACTORY. INTEGRAL CONTROL PANEL SHALL BE HOUSED IN A NEMA 1 ENCLOSURE WITH HINGED ACCESS DOOR. ELECTRIC COILS SHALL CONTAIN A PRIMARY AUTOMATIC RESET THERMAL CUTOUT, A SECONDARY REPLACEABLE HEAT UMTTER PER ELEMENT, DIFFERENTIAL PRESSURE AIRFLOW SWITCH AND UNE TERMINAL BLOCK. UNIT SHALL INCLUDE AN INTEGRAL DOOR INTERLOCK TYPE DISCONNECT SWITCH. INDMDUAL COMPONENTS SHALL BE UL USTED OR RECOGNIZED. COILS SHALL INCLUDE MANUAL RESET SECONDARY THERMAL CUTOUTS, UNE FUSING, MERCURY CONTACTORS MOUNTED AND WIRED WITHIN THE CONTROL ENCLOSURE. 15800 - DUCTWORK AND APPURTENANCES 8.10 SHEET METAL DUCTWORK: B. FABRICATE DUCTWORK FROM GALVANIZED SHEET STEEL COMPLYING WITH ANSI /ASTM A -527, LOCKFORMING QUALITY, WITH ANSI /ASTM A -525 G90 ZINC COATING; MILL PHOSPHA11ZED FOR EXPOSED LOCATIONS. C. DUCT SEALANT: UNITED DUCT SEALER, OR EQUAL. CC A FABRICATE AND INSTALL AS RECOMMENDED IN LATEST EDITIONS OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS - -METAL AND FLEXIBLE AND THE ASHRAE GUIDE AND DATA BOOK FOR SHEET METAL DUCTWORK SERVING SUPPLY, RETURN AND EXHAUST SYSTEMS OPERATING BETWEEN -2.0 IN. -W.G. AND +2.0 IN. -W.G. MAXIMUM PRESSURE. INSTALL WHERE INDICATED ON THE PLANS. DUCT SIZES SHOWN ON THE DRAWINGS ARE NOMINAL INSIDE CLEAR DIMENSIONS. WHERE INTERNAL INSULATION IS PROVIDED, DUCT SIZES MUST BE INCREASED APPROPRIATELY TO MAINTAIN THE INDICATED DIMENSIONS. ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND NOISELESS (NO OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSMONS, CONNECTIONS TO AIR TERMINALS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. D. SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE HOT- DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS STRAPS, TRIM AND ANGLES FOR SUPPORT OF DUCTWORK. E. ANY SUPPLY DUCTWORK AND PLENUMS THAT ARE DESIGNED TO OPERATE AT STATIC PRESSURE FROM 0.25 INCHES TO 2 INCHES WATER COLUMN INCLUSIVE WHICH ARE LOCATED OUTSIDE OF THE CONDITIONED SPACE OR IN RETURN PLENUMS SHALL HAVE JOINTS SEALED IN ACCORDANCE WITH SEAL CLASS C AS DEFINED IN THE SMACNA HVAC DUCT LEAKAGE TEST MANUAL. PRESSURE SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT WHERE SUCH DUCTS ARE DESIGNED TO OPERATE AT STATIC PRESSURES OF 1 INCH WATER COLUMN OR GREATER. 8.20 DUCTWORK ACCESSORIES: A. BALANCING DAMPERS: AIR BALANCE, INC., LOUVERS & DAMPERS, INC., RUSKIN, OR EQUAL PROVIDE MANUAL, SINGLE OR MULT1BLADE DAMPERS, AS INDICATED AND AS CONSTRUCTED IN ACCORDANCE WITH SMACNA STANDARDS. B. DAMPERS SHALL HAVE RIGID 2 -IN. X 1/2-IN. X 10 GAUGE CHANNEL FRAMES, BALL OR BRONZE SLEEVE BEARINGS, 1/2-IN. POUSHED STEEL AXLES, 16- GAUGE, REINFORCED, FELT -EDGED BLADES (NOT OVER 8 -IN. WIDE) AND STOP FRAMES AROUND THE ENTIRE PERIMETER. VOLUME DAMPERS IN DUCTS LARGER THAN 12 -IN. X 6 IN. SHALL BE THE OPPOSED BLADE TYPE. DAMPERS IN ROUND DUCTS AND DUCTS 12 -IN. X 6 -IN. AND SMALLER SHALL BE BUTTERFLY TYPE. ROUND BUTTERFLY TYPE VOLUME DAMPERS SHALL BE 30 GAUGE, GALVANIZED STEEL THROUGH 12 -IN. DIAMETER; 28 GAUGE FOR ABOVE 12 -IN. C. ALL DAMPERS SHALL BE EQUIPPED WITH STANDARD QUADRANTS OF SUITABLE SIZE IN EQUIPMENT ROOMS /AREAS AND YOUNG #301A, OR EQUAL, RECESSED -TYPE IN FINISHED AREAS. PROVIDE QUADRANT LOCKING DEVICE FOR EACH DAMPER ON ONE END OF THE SHAFT AND AN END BEARING PLATE ON THE OTHER END FOR DAMPER LENGTHS OVER 12 -IN. PROVIDE EXTENDED QUADRANT LOCKS AND EXTENDED BEARING PLATES FOR EXTERNALLY INSULATED DUCTWORK. APPROVED MANUFACTURERS ARE VENTFABRICS AND YOUNG REGULATOR CO. D. DAMPERS SHALL BE COATED WITH RED ZINC CHROMATE PRIMER OVER A BOND COAT. E. VOLUME DAMPERS, SPUTTERS AND DEFLECTORS SHALL BE PROVIDED IN ALL DUCTS TO PERMIT ACCURATE BALANCING OF THE SYSTEM. THE DAMPERS, SPUTTERS AND DEFLECTORS SHALL BE ADJUSTED TO SATISFY THE HEATING AND VENTILATING REQUIREMENTS OF THE CONDITIONED SPACE AND LOCKED IN PLACE. 8.40 AIR OUTLETS AND INLETS: FURNISH AND INSTALL TTTUS, KRUEGER, OR APPROVED EQUAL AS SCHEDULED. OPPOSED BLADE VOLUME DAMPERS FOR REGISTERS SHALL BE TITUS SERIES AG -35, KRUEGER SERIES OBC, OR EQUAL, OPPOSED BLADE TYPES WITH VERTICAL BLADES AND SCREWDRIVER SLOTS OR ALLEN WRENCH ADJUSTMENT ACCESSIBLE THROUGH THE REGISLU <. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MISCELLANEOUS ITEMS AS NECESSARY FOR A COMPLETE AND PROPER INSTALLATION IN THE TYPES OF WALLS AND CEIUNGS USED ON THE PROJECT. THIS SHALL INCLUDE SUCH ITEMS AS FASTENERS, PLASTER RINGS, SUPPORTS, ETC. 8.60 FLEXIBLE CONNECTIONS: VENTFABRICS, INC., DURO DYNE, OR EQUAL PROVIDE FLEXIBLE DUCT CONNECTIONS WHEREVER DUCTWORK CONNECTS TO VIBRATION ISOLATED EQUIPMENT AND WHERE SHOWN OR NOTED. MAKE AIR -TIGHT JOINTS. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR THERMAL, AXIAL, TRANSVERSE AND TORSIONAL MOVEMENT. 15900 - SYSTEM CONTROL AND OPERATION 9.10 SPACE TEMPERATURE CONTROL FURNISH AND INSTALL, UNLESS NOTED OTHERWISE, ALL THERMOSTATS, SENSORS, CONTROLLERS, RELAYS, CONTACTORS, DAMPERS, ACTUATORS, TUBING, CONTROL WIRING AND ALL OTHER ITEMS AND MATERIALS NECESSARY FOR A COMPLETE AND PROPERLY OPERATING TEMPERATURE CONTROL SYSTEM AS SPECIFIED BELOW. ALL THERMOSTATS AND OTHER CONTROL COMPONENTS SHALL BE HONEYWELL, OR APPROVED EQUAL, UNLESS SPECIFIED OTHERWISE ALL CONTROL WIRING SHALL BE BY MECHANICAL CONTRACTOR AND SHALL BE INSTALLED IN CONDUIT. 9.11 THERMOSTAT: REFER TO "HVAC CONTROLS ". 9.20 SEQUENCE OF CONTROLS: REFER TO "HVAC CONTROLS. 15950 - TESTING, ADJUSTING, BALANCING 9.51 THIS CONTRACTOR SHALL EMPLOY AN INDEPENDENT NEBB, AABC, OR TABB CERTIFIED TESTING AND BALANCING CONTRACTOR. THIS INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS. THE PERSON OR AGENCY RESPONSIBLE FOR BALANCING OF THE SYSTEMS SHALL DOCUMENT IN WRITING THE AMOUNT OF OUTDOOR AIR BEING PROVIDED AND DISTRIBUTED FOR THE BUILDING OCCUPANTS AND ANY OTHER SPECIALTY VENTILATION. TWO COPIES OF A WRITTEN REPORT IN FORMAT USTED ABOVE SHALL BE SUBMITTED TO THE OWNER, TWO COPIES SHALL BE SUBMITTED TO THE LANDLORD PRIOR TO OCCUPANCY, AND TWO COPIES SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. 9.52 ENSURE ALL VAV BOXES ON THIS AIR HANDLER / ROOFTOP UNIT ARE ADJUSTED TO THEIR RESPECTIVE MAXIMUM SETPOINTS DURING BALANCING TO ENSURE PROPER AIRFLOW WHEN SYSTEM IS OPERATING AT MAXIMUM (PEAK) COOLING CAPACITY. COORDINATE SETTING OF VAV BOXES IN OTHER TENANT SPACES IN FIELD WITH LANDLORD'S FIELD REPRESENTATIVE. 9.53 HVAC CONTROL SYSTEMS SHALL BE IES1LD TO ASSURE THAT CONTROL ELEMENTS ARE CALIBRATED, ADJUSTED, AND IN PROPER WORKING CONDITION. CITY RECEIVED TUKWILA Ma P0 3 2008 PERMIT CENTER 0 r�1 Ca 61 7 C x m 0 6 2 w c) CO (1) ..J Z < 0 U �= Q U = LL W U eL (J) mil PA mire SHEET NUMBER M-3 SHEET 14 OF 17