Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-065 - IFLOORING
IFLOORING 17616 WEST VALLEY HY M08-065 Parcel No.: 2523049017 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC -10/06 City1111f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17616 WEST VALLEY HY TUKW Value of Mechanical: $6,252.00 Type of Fire Protection: IFLOORING 17616 WEST VALLEY HY , TUKWILA WA BROMEL DAVID K 3409 S LAURELHURST DR NE , SEATTLE WA Contact Person: Name: JESICA ROGERS Address: 4554 2 AV N , KENT WA Contractor: Name: HERM:ANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL (12) NEW BUILDING STANDARD DIFFUSERS AND RE -WORK DUCT TO BH1'1 hR SERVE NEW LAYOUT Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,00C CFM 0 >10,00C CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 EOUIPMENT TYPE AND OUANTITY * *continued on next page ** M08 -065 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 796 -5814 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 M08 -065 03/14/2008 09/10/2008 Fees Collected: $248.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 12 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 03 -14 -2008 Permit Center Authorized Signature: construction or t e p = ormdEbe of Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -065 Issue Date: 03/14/2008 Permit Expires On: 09/10/2008 ed to sign and obtain this mechanical permit. Date: 3) 1 L{ -00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting o this permit does not - presume to give authority to violate or cancel the provisions of any other state or local laws regulating Dat This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period o:!180 days from the last inspection. M08 -065 Printed: 03 -14 -2008 1: ** *BUILDING DEPARTME7TI' CONDITIONS * ** • City of Tukwila Parcel No.: 2523049017 Address: 17616 WEST VALLEY HY TUKW Suite No: Tenant: IFLOORING Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -065 Status: ISSUED Applied Date: 03/06/2008 Issue Date: 03/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shat, be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be clone in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition ru:oble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installatior, instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuar.ce of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M08 -065 Printed: 03 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the perform u e of work. Signature: _ 1 Print Name: t1 ` \ doc: Cond - 10/06 M08 - 065 Date:6 \ ordinances governing or local laws regulating Printed: 03 -14 -2008 CITY OF TUKWILA Community DevelopmeDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us - 140 \Iv ("st Na■\eu Tenant Name: )Dr n C Property Owners Name: 1 F-100 Site Address: Mailing Address: ` Name: E -Mail Address:_ Contact Person: E -Mail Address: Mailing Address: 2 -2- -■ 7 Company Name: Y ( ' QA Applicationfforms- Applications On Line 1.1-2006 - Mechanical Permit Application.doe Revised: 4-2006 bh MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** >In, C(1 King Co Assessor's Tax No.: 252 L-1 O ' t) l9 City wbo:do we when your permit is‘ready tobe issued Mailing Address: s 22.1 Z 2 s Day Telephone: 21) 9 c 1 LQ - Fj%- 114 \ wt \ Pr C g � Cit State (� t rn ' I Fax Number: 26 5 - ` R Suite Number: New Tenant: Floor: ❑.... 1..No State Zip City State Zip Day Telephone: Contact Person: ' \ ,• n \( 1 E -Mail Address: V `c n• (lin Fax Number: 2 )04- � j� � j - 0 -1g0D Contractor Registration Number: \\('''r N\RC__C)� 1 Expiration Date: 2, v l� 'AR ITECTrOFF•R A ll land muist,be wet stam edtb Architect of Reco; .t °` • � K' �} o-. �,b JE. ' bx� ,4.�� tt ;a_�.. > '. i, rte• ta• ... *� �f - , Company Name: tCt,r Mailing Address: E$ Gl EER ;OF. RECORD All plans must be wet stamped by Engineer, of Reeord�- t t -, °' 'L . • • :i ° _ t,- -ati . -- ,nn' .3 d , 1 . ''. is y{ ° «,.. ✓ r t'... . +, Company Name: l- errY� nso \ --) a5--- Mailing Address: � 7 . fli tact Person: ��" ��' - ail Address: c t . State City Day Telephone: Fax Number: Zip City — State - 7.. Fax Number: 20 ei\a Page 1 of 2 Unit Type: Qty Unit•Type: Qty •Unit Type: Qty " Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser J2_ 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/WatI/Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid pri. $ �1 7 - CJ v Scope of Work (please provide detailed information): Use: Residential: New .... 0 Replacement .... Commercial: New .. Replacement .... 0 Fuel Type: Electric 0 Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: 01' Sr' A plicable�.to all perlmllts in this apphcabon :. -':, �.:5. 4 13a4 . e -.414. - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR H ' IZ GENT: 22 I x Signature: `r Date: J `� �JU Print Name :_ ��l` ` Day Telephone: nn� Mailing Address: \ 22,\ 2 e � A- C i City State Zip Date Application Accepted: 0...b 1 (21) Q :1Appliations1Fonms- Appliations On Line\3 -2006 - Mechanical Permh Appliation.doc Revised. 4.2006 bh Date Application Expires: • ocii0(0 Staff Initials: 4)1 Page 2 of 2 Receipt No.: R08 -00642 Payee: HERMANS ON COMPANY LLP ACCOUNT ITEM LIST: Description doc: Receiot -06 MECHANICAL - NOIRES PLAN CHECK - NOIRES City of Tukwila Department of Communit Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 57022 248.75 RECEIPT Parcel No.: 2523049017 Permit Number: M08 -065 Address: 17616 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 03/06/2008 Applicant: IFLOORING Issue Date: Initials: JEM Payment Date: 03/06/2008 12:07 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000.322.102.00.0 199.00 000/345.830 49.75 Total: $248.75 Payment Amount: $248.75 9501 03/06 9710 TOTAL 248.75 Printed: 03 -06 -2008 Project: J --�'�° r ! Type of Insp ction: a tea- t e.c �tf C Address: I'1(vl le y Date Called: Date Wanted: -=(- 2.2. .10 r _-, a.m ., Special Instructions: �/ p .m. Requester: Phone No: !l e - 008 - _3 4 t3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspecci>r: 1 0 $58.30 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: All -o PERMIT NO. (206)431 - 1 31 670 Date: I ' • • • -�'a.l_4.oEAoZ� sR . ._.a. Project �F/oa IN Ty a of Ins ection: w.6c h - iti Date Cal red: Address: 1 / cI )eS -t / 3 Special Instructions: Date Waned: �--� m. Requester: Phone ,��No: � �7 o- VC-- ! '608 • L. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION V= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 IM Approved per applicable codes. COMMENTS: 1ii+r1;wan, li f �� 3r >.+ rr f c- eee Receipt No.: - � INSPECTION RECORD Retain a copy with permit • ter. -.. - YYli.8-465 PERMIT NO. Corrections required prior to approval. 1 lnspector: Date: ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: t COMMENTS: f � ,�j l t' n u ' T ype ^1 Inspe , e . . 4 J 4- fit (1,060t4 — Du ‹ 1 J J Sk . Address: (./A-1( e.7 Date Called: A ( . PJsI_ f r - c ( LA PP -- 7) r- ir p -- : .., 1p P c,T7J 4 --- a m Requester: Phone No: Projec T ype ^1 Inspe Ion: 1 (. Address: (./A-1( e.7 Date Called: Special Instructions: Date anted: - 3 - ve a m Requester: Phone No: INSPECTION NO. Approved per applicable codes. nspect¢r: Receipt No.: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Corrections required prior to approval. Dater v6/ J $50.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa d at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. /9L Date: • PERMIT COORD CORY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -065 DATE: 03 -06 -08 PROJECT NAME: (FLOORING SITE ADDRESS: 17616 WEST VALLEY HY X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Buil tin: r'vision Public Works n Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use. Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Notation: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2 -28-02 Approved with Conditions M'(f 3-1(-0 Fire Prevention n REVIEWER'S INITIALS: DATE: Response to Incomplete Letter # Revision # After Permit Issued Planning Division ❑ Permit Coordinator DUE DATE: 03-11 -08 Incomplete Not Applicable LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DUE DATE: 04-08-08 Not Approved (attach comments) n Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n License HERMACLO05BJ . Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Verify Workers Comp Premium `.status j Ind. Ins. Account Id 01/01/1980 Business Type LIMITED LIABILITY COMPANY Address 1 ' 221 2ND AVE N ti Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date ' /11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC *217NT Next License Associated License Name Role Effective Date Expiration Date IHERMANSON, !RICHARD L PARTNER /MEMBER 01/01/1980 ;ALMON, KEVIN PARTNER /MEMBER 01/01/1980 IMACDONALD, ;JAMES PARTNER /MEMBER 01/01/1980 Look Up a Contractor, Electricaan or Plumber License Detail 14`041tigwn5cacc. Dcpan Aiborand ti du • License Information Business Owner Information Topic Index 1 Contact Info Home Safety Claims 8: Insurance c Workplace Rights Find a Law or Rule Get a Form or Publication Look Up a Contractor, Electrician or Plumber • Printer Friendly Verson 1 General/Specialty Contractor IA business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment ,of account and carry general liability insurance. Search I Trades & Licensing Page 1 of 2 i; Help https: // fortress .w,a.gov /lni/bbip/Detail.aspx ?License= HERMACL005BJ 03/14/2008 MINIMUM DUCT INSULATION (R- VALUE) LAST UPDATED: 12/20/04 DUCT TYPE DUCT LOCATION INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R -7 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE: IN CONCRLIL, IN GROUND R -5.3 1,2 SUPPLY WITH <55° OR >105° AIR TEMPERATURE WITHIN CONDITIONED SPACE R -3.3 1,2 MINIMUM PIPE INSULATION (INCHES) LAST UPDATED: 12/01/04 SERVICE FLUID TEMP T INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING °F RUN -OUTS UP TO 2 1 & LESS >1 TO 2 >2 TO 4 >4 TO 6 >6 HWS &R 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 HWS &R 105 -140 0.24 -0.28 100 0.5 1.0 1.0 1.0 1.5 1.5 CHWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 CHWS &R <40 0.23 -0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 CDWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.5 1.0 DRAWING INDEX SHEET NO. SHEET TITLE M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC TA3.01 FIRST FLOOR PLAN - HVAC A AC ACH ACT AD ADD'L AFF AFG AHU ALU M AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DBA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT ELECTRICAL /ELECTRIC EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED /CONNECTION CONTINUOUS /CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC /CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GWB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ("T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HZ HERTZ BC INTERNATIONAL BUILDING CODE CW INDUSTRIAL COLD WATER D INSIDE DIAMETER /DIMENSION E INVERT ELEVATION MC INTERNATIONAL MECHANICAL CODE N INCHES N WC INCHES WATER GAUGE PLV INTEGRATED PART LOAD VALUE KW KILOWATTS LAT LEAVING AIR TEMPERATURE LB /LBS POUND /POUNDS LD /LIN DIFF LINEAR DIFFUSER LF /LIN FT LINEAL FOOT /FEET LPG LIQUID PROPANE GAS LVG LEAVING LWA SOUND POWER LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MAU MAKE UP AIR UNIT MBH 1000 BRITISH THERMAL UNITS MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MFR MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM /MINUTE MT MOUNT MTD MOUNTED MUW MAKE -UP WATER N/A NOT APPLICABLE NC NORMALLY CLOSED /NOISE CRITERIA NG /NGAS NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN /NUMBER NPW NON - POTABLE WATER OA /OSA OUTSIDE AIR OB OPPOSED BLADE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION P PUMP PCF POUNDS PER CUBIC FOOT PD PRESSURE DROP PH PHASE POC POINT OF CONNECTION PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANITY R RETURN GRILLE /RELOCATED /RETURN RA RETURN AIR RD /RND ROUND REF REFERENCE REG REGISTER REQ'D REQUIRED RF RELIEF RG RETURN GRILLE RL REFRIGERANT LIQUID RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION S SUPPLY SA SUPPLY AIR SAT SATURATION SD SMOKE DETECTOR S/D SLIP & DRIVE CONNECTION SEER SEASONAL ENERGY EFFICIENCY RATING SENS SENSIBLE SG SUPPLY GRILLE SL SOUND LINED SM SPIRALMATE /SHEETMETAL SPEC SPECIFICATION SO SCREENED OPENING SOG SLAB ON GRADE SP STATIC PRESSURE SQ FT SQUARE FEET SR SIDE WALL REGISTER SS STAINLESS STEEL STRUC STRUCTURAL T TRANSFER TA TRANSFER AIR TEMP TEMPERATURE /TEMPORARY TBD TO BE DETERMINED TG TRANSFER GRILLE TOC TOP OF CONCRETE /CURB TOD TOP OF DUCT TOS TOP OF STEEL /TOP OF SLAB TOT TOTAL TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VIAQC VENT. AND INDOOR AIR QUALITY CODE VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WALL /WALLS, WRAPPED DUCT WB WET BULB WG WATER GAUGE W/ WITH W/0 WITHOUT W /SF WATTS PER SQUARE FOOT WSEC WASHINGTON STATE ENERGY CODE 2 MECHANICAL LEGEND �1 Ox10 10x10 1Ox10 ;,' a 1Ox10 100 C 1, m • b 10 'i) MEM 1 =1-vvv.c; 8 �-- CHWS 2- cHwR 2 RL XX0 X X X X° CD1 -100 o i -=S- t I z ] t-- -r z CHWS - cHwR -5 � Rs--s 2- NG -S LPG 2- COWS COWS -5 2- CDWR CDWR -5 2---- r--- -- HWS --s z--- -- HWR---- --�- -5 2- COND COND -5 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT -- TURNING DOWN OR AWAY ROUND DUCT ROUND DUCT OVAL DUCT OVAL DUCT - DUCT OVERLAP 100 BOOT TAP 45° TAP 10� VOLUME DAMPER TRANSITION FLEX CONNECTION SMOKE DAMPER FIRE DAMPER - TURNING UP OR TOWARD - TURNING DOWN OR AWAY TURNING UP OR TOWARD TURNING DOWN OR AWAY CHANGE OF ELEVATION RISE(R) DROP(D) TURNING VANES /SPtJTfERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) AIR FLOW DIRECTION DRAWN AIR) MOTOR OPERATED DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) ROUND DUCT SYMBOL FLAT OVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE ---CFM SIZE THERMOSTAT /TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL 0 z 5 - MOUNTED GRIT I F PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2006 IBC, 2006 WSEC, 2006 IMC & 2006 WSVIAQC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. DISCREPANCIES PRIOR PROCEEDING WITH STHE DETAILS, NOTIFY ENGINEER OF ANY 5. SHA N B A S FOR OTHER OSIMI SHOWN WORK. ED FOR ANY PART RESOLVCDDIN AILS MANNER, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL JOINTS IN SUPPLY AND RETURN AIR DUCTS SHALL BE SEALED TO SMACNA C CLASS, OR ABOVE. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: A. 0% TO 100% OF THE DESIGN SUPPLY AIR B. CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. C. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR RELIEF AND EXHAUST IS OFF BE EQUIPPED POWER MOTORIZED AS OR BY ENERGY CODE. 13. TYPES WEEK AND SHALL DEADBAND SEITINGG O F At LEAST 5 OF F BETWEEN SEVEN DIFFERENT SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE MICROPROCESSOR AND BE CAPABLE OF RESLIIING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. DUCT SYSTEMS SHALL COMPLY WITH MECHANICAL CODES AND SMACNA STANDARDS. DUCTS 28" AND LARGER, WHICH ARE SUSPENDED MORE THEN 12" BELOW STRUCTURAL SYSTEM, SHALL BE EARTHQUAKE BRACED. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL SEIZMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EbUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM PER CODE. SMOKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER- WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. A ALL VERTICALDJOINTSIGINSIDE SHAFTS SHAFT SHALL THE PROVIDED WITH�A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC) B. TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) C. ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILING WITH ROCK WOOL IS NOT ACCEPTABLE D. ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. E. USE SECTION 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. F. ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G--KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND WT H OTHER AMI INOACCORDANCERWITH APPROXIMATE. SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF INSTALLATION). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM. CONDENSER WATER (FOR NON- ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED) • APN NUMBER 2523049017 LEGAL DESCRIPTION S 329.85 FT OF GL 7 LY BET PST & P R/W & CO RD LESS ST HWY VICINITY MAP NO SCALE SITE MAP NO SCALE FILE COPY . frloB s PIar MAW woof 1s Maid te MRS and omissions. Approval of won doh does not dze the down ray . C or ot e. of ate' Copy L- lee ° Receipt BY �1 >:�� MK, City of Tukwila BUILDING DIVISION REVISIONS No changes shat be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions wi l require a new plan submittal I and may include aonal plan review fees. i ° kWit E FCC. CODE CO O Yt C E A ppOOV '': SAP 1 Ot TutoniF ': BUILDN QIL SEPARATE PERMIT REQUIRED FOR: DMechanical nrEiectrigt etPiumbin Vass Piping City of Tukwila BUILDING DIVISION CITY OF TUY.V4tL MAR 0 6 2008 PERMIT CENTER AD 0(eC ISSUE FOR PERMIT Design Drawn Checked Scale Issue Date Hermanson Hermanson Company LP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www_hermanson.com Contractor Reg #: HERMACLOO5BJ iFLOOR TI 17616 WEST VALLEY HWY TUKWILA, WA Revisions 3 -5 -08 CG ISSUE FOR PERMIT No. Date By Description Design Team CG ER DN AS NOTED Drawing Number C- XXXX -XXX Project Number 11 -8 -0176 3-5-08 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M0.00 1 OF 2 DC OFFI - 1 2 ; V EGGCRATE GRILL H'HOOD FOR T1ON TO fE}IIUSE PEN 12 %-2 . CONFERENCE WAITING OPEN TO SECOND FLOOR 11 CEILING ABOVE. " I NO LIGHTING • . OR CEIUNG I CHANGE U %ER THIS PE:1fl. R 'EPTION STORE INVENTORY 126 kt f7m frt CQ n 1 ! FE �ALr� .. _.... - ,.,; C NFE 'Ef?ICE �JFEREN E., 105 NEW SUSPENDED CEIUNG SYSTEM AT 13'76" A.F.F. CROSSHATCH INDICATES AREAS TO RECIEVE R -25 BATT INSULATION ABOVE CEIUNG GRID. - 0' - 0" NEW SUSPENDED CEILING SYSTEM AT 12' -0" A.F.F. WAREHOUSE (127) ALL WAREHOUSE AREA UGHTNG EXISTING WAREHOUSE 127 FLOOR PLAN (AREA UNDER THIS PERMIT) Scale: NEW SUSPENDED CEIUNG SYSTEM AT 12'70" A.F.F. 60' -0" • 10 - SECURE STORAGE 125 715' -0" _. CROSSHATCH OPEN . INDICATES AREAS TO OFFICE _ RELIEVE R -25 BATT I�5ULA11ON7ErOVE ..- —..-- . , CEILING GRID. NEW SUSPENDED CEILING SYSTEM AT 12' -0" A.F.F. CEILING INSULATION PER WALL SECTION O (aS TITUS Pict' LAY S1v ViFfvS a.irsY caP' egg :•�. # <.,,,�... tar LArCill (gin cierwits Tiros Brae L- Tl fyxz r CEILING /LIGHTING SYMBOLS &LEGEND (EX IT1 SUSP. ACOUST. TILE CEILING AND GRID SYSTEM PER REFLECTED CEILING PLAN Scale: 1 1/2'=1-O" 7/8" EXISTING SUSPENDED ACOUSTICAL TILE CEILING NEW 2' X 4' SUSPENDED ACOUSTICAL TILE CEILING NEW COMPACT FLOURESCENT UGHT FIXTURE EXISTING 2' X 2' FLUORESCENT LIGHT NEW 2' X 2' FLUORESCENT LIGHT 0 FIXTURE W/ 2 - T8 LAMPS AND ELECTRONIC BALLAST NEW 2' X 2' FLUORESCENT LIGHT WITH BATTERY BACK -UP (NIGHTIME /PATHWAY UGHTING) EXISTING 2' X 4' FLUORESCENT LIGHT NEW 2' X 4' FLUORESCENT LIGHT FIXTURE W 2 - T8 LAMPS AND ELECTRONIC BALLAST NEW 2' X 4' FLUORESCENT LIGHT WITH BATTERY BACK -UP (NIGHTIME/PATHWAY UGHTING) EXISTING LIGHTED EXIT SIGN NEW LIGHTED EXIT SIGN NOTE: ALL RECESSED CAN LIGHTS TO BE (IC) INSULATION CONTACT RATED FIXTURES. TENT UCHT FIXTURE W/ CEILING TILES FOR INSULATION COVER, SIMILAR TO UL DESIGN G216. 2 X4 RECESSED FLUORESCENT UGHT FIXTURE PER REFLECTED CEILING PLAN FIXTURE TENT AT SUSP. CELING EXISTING COMPACT FLOURESCENT LIGHT FIXTURE IF HANGER WIRE IS OUT OF PLUMB GREATER THAN 1:6 is COUNTER SPLAY PER ASTM C636 WALL WHICH PEN I HATES CEILING GRID WALL EDGE MOLDING (101' (Z/44 AZA MIN . MAX. 8" 1i MIN. 3/4' . JN ATTA',HFD WA..11 EDGE TRACK AT SUSP. CEILING Scale: 3 " -1' —O" SEISMIC N.T.S. WALL EDGE MOLDING BRACE AT SUSPENDED CEILING SUSP CEILING BRACE AT PERIMETER N.T.S. #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE © EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART © UNATTACHED WALLS ONLY TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID CROSS TEE PER ASTM C635 STEEL STUD COMP . E SIQN POST AS REQUIRED. 'BY-1 BUILDING OFFICIAL.~ • ' '" CROSS TEE MAIN CEILING PER ASTM 0635 BEAM PER ASTM C635 CEILING INSTALLATION REQUIREMENTS PENETRATIONS. • CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING. • CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND BRACED. SUSPENDED CEILING WILL BE SUBJECT TO SPECIAL INSPECTION AS REQUIRED BY LOCAL BUILDING OFFICIAL. • IF CEILING SYSTEM TO BE INSTALLED IS NOT AS SPECIFIED ABOVE, CONTRACTOR SHALL SUBMIT ALTERNATIVE MATERIAL AND METHODS AS DESCRIBED IN I.B.C. SECTION 104.11 TO LOCAL BUILDING OFFICIAL. EXPANSION JOINT AT SUSP. CEILING Scale: 3 " =1' -0" #12 HANGER WIRE TYP. TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) • SUSPENDED CEILINGS SHALL BE BRACED AGAINST LATERAL MOVEMENT DUE TO EARTHQUAKE PER ASTM C636. IN THE ABSENCE OF AN ENGINEERED DESIGN THE FOLLOWING BRACING SYSTEM WILL BE REQUIRED. FOUR NO. 12 GA STEEL WIRES SHALL BE ATTACHED TO A MAIN RUNNER WITHIN 2 INCHES OF A CROSS RUNNER. THE WIRES SHALL BE SPLAYED 90 DEGREES TO EACH OTHER AND RUN UP TO STRUCTURE ABOVE AT AN ANGLE NOT TO EXCEED 45 DEGREES FROM THE HORIZONTAL. A COMPRESSION STRUT SHALL EXTEND FROM THE MAIN RUNNER AT THE ATTACHMENT OF THE WIRES VERTICALLY AND BE ATTAC - 1ED TO THE STRUCTURE ABOVE AS REQUIRED BY BUILDING OFFICIAL. SUCH BRACING SYSTEMS SHALL BE PROVIDED AT A SPACING NOT TO EXCEED 12 FEET IN BOTH DIRECTIONS, BEGINNING AT A POINT NOT TO EXCEED 6 FEET FROM WALLS, VERTICAL AND PERIMETER HANGERS INSTALLED PER ASTM C636 AND MANUFACTURERS REQUIREMENTS. LIGHTING FIXTURES WHICH WEIGH LESS THAN 56 POUNDS SHALL BE ATTACHED TO THE CEILING GRID SYSTEM AND TO BUILDING STRUCTURE BY AT LEAST 2 NO 12 GAGE WIRES. UGHT FIXTURES WHICH WEIGH 56 POUNDS OR MORE SHALL BE SUSPENDED FROM THE STRUCTURE INDEPENDENT OF THE CEILING GRID, AND AN ENGINEERING DESIGN SHALL BE SUBMITTED TO SUBSTANTIATE THE SUSPENSION SYSTEM. MECHANICAL EQUIPMENT SHALL BE SUPPORTED INDEPENDENT OF THE CEILING SUSPENSION SYSTEM. • MINIMUM 2" WIDE WALL MOLDING • GRID MUST BE ATTACHED TO TWO ADJACENT WALLS - OPPOSITE WALL MUST HAVE A 3/4" CLEARANCE. • ENDS OF MAIN BEAMS AND CROSS TEES MUST BE TIED 'TOGETHER TO PREVENT THEIR SPREADING. • PERIMETER SUPPORT WIRES MUST BE WITHIN 8" OF CEILING EDGE. • PROVIDE MANUFACTURERS HEAVY DUTY GRID SYSTEM. • CEILING AREAS OVER 1,000 SF MUST HAVE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. • CEILING AREAS OVER 2,500 SF MUST HAVE MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT REVIEW PARTmONS.� � • CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART 0 UNATTACHED WALLS ONLY R:777 ... CITY t_I- i UYYv LA MAR Q 6 2008 PERMIT CENTER #12 HANGER WIRE ANCHORED TO STRUCTURE ABOVE EXPANSION JOINT PER CEIUNG MANUF. X 11 ' Cyr Of Tuk1 ' 1 BULL DImg_a V(S [E D RES 1/29/ 2OI 0 e -1 Parcel No.: 2523049017 Address: Suite No: Tenant: Name: Address: Owner: Name: Address: doc: IMC -10/06 City1111f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17616 WEST VALLEY HY TUKW Value of Mechanical: $6,252.00 Type of Fire Protection: IFLOORING 17616 WEST VALLEY HY , TUKWILA WA BROMEL DAVID K 3409 S LAURELHURST DR NE , SEATTLE WA Contact Person: Name: JESICA ROGERS Address: 4554 2 AV N , KENT WA Contractor: Name: HERM:ANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA Contractor License No: HERMACLOO5BJ MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL (12) NEW BUILDING STANDARD DIFFUSERS AND RE -WORK DUCT TO BH1'1'hR SERVE NEW LAYOUT Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,00C CFM 0 >10,00C CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 0 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 EOUIPMENT TYPE AND OUANTITY * *continued on next page ** M08 -065 Permit Number: Issue Date: Permit Expires On: Phone: Phone: 253 - 796 -5814 Phone: 206 - 575 -9700 Expiration Date: 08/25/2008 M08 -065 03/14/2008 09/10/2008 Fees Collected: $248.75 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 12 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 03 -14 -2008 Permit Center Authorized Signature: construction or t e p = ormdEbe of Signature: Print Name: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: M08 -065 Issue Date: 03/14/2008 Permit Expires On: 09/10/2008 ed to sign and obtain this mechanical permit. Date: 3) 1 L{ -00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting o this permit does not - presume to give authority to violate or cancel the provisions of any other state or local laws regulating Dat This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period o:!180 days from the last inspection. M08 -065 Printed: 03 -14 -2008 1: ** *BUILDING DEPARTMENT CONDITIONS * ** • City of Tukwila Parcel No.: 2523049017 Address: 17616 WEST VALLEY HY TUKW Suite No: Tenant: IFLOORING Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Permit Number: M08 -065 Status: ISSUED Applied Date: 03/06/2008 Issue Date: 03/14/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shat, be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be clone in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition ru:oble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Thkwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: Cond -10/06 * *continued on next page ** M08 -065 Printed: 03 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the perform u e of work. Signature: _ 1 Print Name: t\S doc: Cond -10/06 M08 -065 Date:6 \ ordinances governing or local laws regulating Printed: 03 -14 -2008 CITY OF TUKWIL4 Community DevelopmeDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us -(1 9 \INfeSt Na■\eu Tenant Name: )[)r k n Property Owners Name: I F-`VU Site Address: Mailing Address: ` Name: E -Mail Address:_ Contact Person: E -Mail Address: f C N.. Mailing Address: l. 2.2_ 7 Company Name: \ Y ' QA Appliationfforms- Applications On LineU.2006 - Mechanical Permit Application.doe Revised: 4.2006 bh MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** >fn, C(1 King Co Assessor's Tax No.: 252,t' L-1 O t) l9 City wbo:do we : e _ o ta nct when your permit Is‘ready to issued Mailing Address: s 22.1 Z Day Telephone: 21) 9 C I LP — 5 \ wt \ Pr C g � Cit State (� t rn ' I Fax Number: 2Q\ 9 5 - ` R Suite Number: New Tenant: Floor: ❑ .... Yes 1..No State Zip City State Zip Day Telephone: Contact Person: ' \ ,• n \( 1 E -Mail Address: V `c iV -• (lin Fax Number: 7 )04 51 3j - CROD Contractor Registration Number: \\('' r N\(),, 4j Expiration Date: .2 v lC ' AR CH ITECTrOFF•R R ECORD} A ll land muist,be wet s la m" ed Archit of c o lit -, _ yt a. , ,� : vI V . Re ft, p �~ • � � K' �} o- �b JE . ' bx� ,4.�� tt ;a_�.. > '. i, rte• ta• ... *� �f - , Company Name: tCt,r Mailing Address: ii.g EE �•4' R , ;,OF.RECORD MI plt�ns must be wet stamped by Engineer, of Record, Y '0.._ 'F�°�t'L. •n +° _I ^ --ati � .3 5 � ''. is i y{ ° P �,.. " ✓ . 4- x t'... . + , Company Name: l n U \ --) a5--- Mailing Address: � 7 . fli tact Person: E(" ��' - ail Address: c t . State City Day Telephone: Fax Number: Zip City — State Z_ Fax Number: 20 ei\a Page 1 of 2 Unit Type: Qty Unit•Type: Qty Unit Type: Qty " Boiler /Compressor: Qty Fumace<100K BTU Air Handling Unit >10,000 CFM Fire Damper 0-3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser J2_ 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/WalVFloor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid pri. $ �1 7 c2 CJ v Scope of Work (please provide detailed information): �n ti \ lZ fl L - rik S i l 11 Use: Residential: New .... 0 Replacement .... Commercial: New .. Replacement .... 0 Fuel Type: Electric 0 Gas ....❑ Other: Indicate type of mechanical work being installed and the quantity below: 01' Sr' A plicable�.to all perlmllts in this apphcabon :. -':, �.:5. 4 i 13a4 . e - .41 4. - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING,O OR H ' IZ GENT: 22 I x Signature: `r Date: J `� �JU Print Name :_ ��l` ` Day Telephone: nn� Mailing Address: \ 22,\ 2. e � A- City State Zip Date Application Accepted: 0...b 1 (21) Q :1Appliations1Fonms- Appliations On Line\3 -2006 - Mechanical Permh Apptiation.doc Revised. 4.2006 bh Date Application Expires: • ocii0(0 Staff Initials: 4)1 Page 2 of 2 Receipt No.: R08 -00642 Payee: HERMANS ON COMPANY LLP ACCOUNT ITEM LIST: Description doc: Receiot -06 MECHANICAL - NOIRES PLAN CHECK - NOIRES City of Tukwila Department of Communit Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Payment Check 57022 248.75 RECEIPT Parcel No.: 2523049017 Permit Number: M08 -065 Address: 17616 WEST VALLEY HY TUKW Status: PENDING Suite No: Applied Date: 03/06/2008 Applicant: IFLOORING Issue Date: Initials: JEM Payment Date: 03/06/2008 12:07 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Descriptio Amount Account Code Current Pmts 000.322.102.00.0 199.00 000/345.830 49.75 Total: $248.75 Payment Amount: $248.75 9501 03/06 9710 TOTAL 248.75 Printed: 03 -06 -2008 Project: J-J-to.f J41 le y Type of Insp ction: J tfr )■.,:t__V dute.AA--vt ( Date Called: Date Wanted: -=(- 2-2. e r Arf _-, a.m ., Address: I'1(vl Special Instructions: �/ p .m. Requester: Phone No: !t - 008 - _3 4 t3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspecci>r: I 0 $58.30 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Mafj - D(oS PERMIT NO. (206)431 - 1 31 670 Date: I ' • • • -�'a.l_4.oEAoZ� sR . ._.a. Project �F/oa IN Ty a of Ins e ction: w.6c h - iti Date Cal red: Address: I / cI )eS -t / 3 Special Instructions: Date Waned: �--� m. Requester: Phone ,��No: � �7 o- VC-- ! '608 • L. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION V= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 IM Approved per applicable codes. COMMENTS: Receipt No.: - � INSPECTION RECORD Retain a copy with permit • ter. -.. - YYli.8-465 PERMIT NO. Corrections required prior to approval. 1 lnspector: Date: ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: t COMMENTS: l t ' ni (J ' T ype ^1 Inspe , ti t e 4 J 4- (1,060t4 - Du‹ - 13 J SF . Address: (./A-1( e.7 Date Called: A 1. PJsI_ f PP rJ iA - (-Aft LA : k -- r- [ p -- : .., 1p P cJ J 4 '-- a m Requester: Phone No: Projec T ype ^1 Inspe Ion: 1 (. Address: (./A-1( e.7 Date Called: Special Instructions: Date anted: - 3 - ve a m Requester: Phone No: INSPECTION NO. Approved per applicable codes. nspect¢r: Receipt No.: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Corrections required prior to approval. Dater v6/ J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be pa d at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. /9L Date: • PERMIT COORD CORY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M08 -065 DATE: 03 -06 -08 PROJECT NAME: (FLOORING SITE ADDRESS: 17616 WEST VALLEY HY X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Buil tin: r'vision Public Works n Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center Use. Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved n Notation: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Documents/routing slip.doc 2 -28-02 Approved with Conditions M'(f $ 3-11 -p6 Fire Prevention n REVIEWER'S INITIALS: DATE: Response to Incomplete Letter # Revision # After Permit Issued Planning Division ❑ Permit Coordinator DUE DATE: 03-11 -08 Incomplete Not Applicable LETTER OF COMPLETENESS MAILED: No further Review Required DATE: DUE DATE: 04-08-08 Not Approved (attach comments) n Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: n License HERMACLOO5BJ . Licensee Name HERMANSON COMPANY LLP Licensee Type CONSTRUCTION CONTRACTOR UBI 602004844 Verify Workers Comp Premium `.status j Ind. Ins. Account Id 01/01/1980 Business Type LIMITED LIABILITY COMPANY Address 1 ' 221 2ND AVE N ti Address 2 City KENT County KING State WA Zip 980322945 Phone 2065759700 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date ' /11/2000 Expiration Date 8/25/2008 Suspend Date Separation Date Parent Company Previous License HERMAC *217NT Next License Associated License Name Role Effective Date Expiration Date IHERMANSON, !RICHARD L PARTNER /MEMBER 01/01/1980 ;ALMON, KEVIN PARTNER /MEMBER 01/01/1980 IMACDONALD, :JAMES PARTNER /MEMBER 01/01/1980 Look Up a Contractor, Electricaan or Plumber License Detail 14`041tigwn5cacc. Dcpan Aiborand ti du • License Information Business Owner Information Topic Index I Contact Info Home Safety Claims 8: Insurance c Workplace Rights Find a Law or Rule Get a Form or Publication Look Up a Contractor, Electrician or Plumber • Printer Friendly Verson I General/Specialty Contractor IA business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment ,of account and carry general liability insurance. Search I Trades & Licensing Page 1 of 2 i; Help https: // fortress .w,a.gov /lni/bbip/Detail.aspx ?License= HERMACL005BJ 03/14/2008 MINIMUM DUCT INSULATION (R- VALUE) LAST UPDATED: 12/20/04 DUCT TYPE DUCT LOCATION INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R -7 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE: IN CONCRLIL, IN GROUND R -5.3 1,2 SUPPLY WITH <55° OR >105° AIR TEMPERATURE WITHIN CONDITIONED SPACE R -3.3 1,2 MINIMUM PIPE INSULATION (INCHES) LAST UPDATED: 12/01/04 SERVICE FLUID TEMP 'F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING 'F RUN -OUTS UP TO 2 1 & LESS >1 TO 2 >2 TO 4 >4 TO 6 >6 HWS &R 141 -200 0.25 -0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 HWS &R 105 -140 0.24 -0.28 100 0.5 1.0 1.0 1.0 1.5 1.5 CHWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 CHWS &R <40 0.23 -0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 CDWS &R 40 -45 0.23 -0.27 75 0.5 0.5 0.75 1.0 1.5 1.0 DRAWING INDEX SHEET NO. SHEET TITLE M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC TA3.01 FIRST FLOOR PLAN - HVAC A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP /AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DBA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC /ELECT ELECTRICAL /ELECTRIC EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER /CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT /CONNECTED /CONNECTION CONTINUOUS /CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC /CONDENSER UNIT DOMESTIC COLD WATER /CONDENSER WATER DUCTBOARD /DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GWB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ("T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE /END CAP /ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE /SMOKE DAMPER FOOT /FEET FUTURE FACE VELOCITY GRILLE GAUGE /GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE /REGISTER /DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HZ HERTZ BC INTERNATIONAL BUILDING CODE CW INDUSTRIAL COLD WATER D INSIDE DIAMETER /DIMENSION E INVERT ELEVATION MC INTERNATIONAL MECHANICAL CODE N INCHES N WC INCHES WATER GAUGE PLV INTEGRATED PART LOAD VALUE KW KILOWATTS LAT LEAVING AIR TEMPERATURE LB /LBS POUND /POUNDS LD /LIN DIFF LINEAR DIFFUSER LF /LIN FT LINEAL FOOT /FEET LPG LIQUID PROPANE GAS LVG LEAVING LWA SOUND POWER LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MAU MAKE UP AIR UNIT MBH 1000 BRITISH THERMAL UNITS MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MFR MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM /MINUTE MT MOUNT MTD MOUNTED MUW MAKE -UP WATER N/A NOT APPLICABLE NC NORMALLY CLOSED /NOISE CRITERIA NG /NGAS NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN /NUMBER NPW NON - POTABLE WATER OA /OSA OUTSIDE AIR OB OPPOSED BLADE OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION P PUMP PCF POUNDS PER CUBIC FOOT PD PRESSURE DROP PH PHASE POC POINT OF CONNECTION PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANITY R RETURN GRILLE /RELOCATED /RETURN RA RETURN AIR RD /RND ROUND REF REFERENCE REG REGISTER REQ'D REQUIRED RF RELIEF RG RETURN GRILLE RL REFRIGERANT LIQUID RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION S SUPPLY SA SUPPLY AIR SAT SATURATION SD SMOKE DETECTOR S/D SLIP & DRIVE CONNECTION SEER SEASONAL ENERGY EFFICIENCY RATING SENS SENSIBLE SG SUPPLY GRILLE SL SOUND LINED SM SPIRALMATE /SHEETMETAL SPEC SPECIFICATION SO SCREENED OPENING SOG SLAB ON GRADE SP STATIC PRESSURE SQ FT SQUARE FEET SR SIDE WALL REGISTER SS STAINLESS STEEL STRUC STRUCTURAL T TRANSFER TA TRANSFER AIR TEMP TEMPERATURE /TEMPORARY TBD TO BE DETERMINED TG TRANSFER GRILLE TOC TOP OF CONCRETE /CURB TOD TOP OF DUCT TOS TOP OF STEEL /TOP OF SLAB TOT TOTAL TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VIAQC VENT. AND INDOOR AIR QUALITY CODE VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WALL /WALLS, WRAPPED DUCT WB WET BULB WC WATER GAUGE W/ WITH W/O WITHOUT W /SF WATTS PER SQUARE FOOT WSEC WASHINGTON STATE ENERGY CODE 2 MECHANICAL LEGEND 100 '- m U S 101,31 MEM 1 =1-vvv.c; 8 �-- CHWS 2- cHwR 2 RL XXB X X X X° CD1 -100 o i -=S- t I z ] t-- -r z CHWS -S CHWR -5 � Rs--s 2- NG -5 LPG 2- Cows CDWS -5 2- CDWR CDWR -5 2---- r--- -- HWS --s z--- -- HWR---- --�- -5 2- COND COND -5 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT -- TURNING DOWN OR AWAY ROUND DUCT ROUND DUCT OVAL DUCT OVAL DUCT - DUCT OVERLAP 100 T. BOOT TAP 45° TAP 10� VOLUME DAMPER TRANSITION FLEX CONNECTION SMOKE DAMPER FIRE DAMPER - TURNING UP OR TOWARD - TURNING DOWN OR AWAY TURNING UP OR TOWARD TURNING DOWN OR AWAY CHANGE OF ELEVATION RISE(R) DROP(D) TURNING VANES /SPtJTfERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) AIR FLOW DIRECTION DRAWN AIR) MOTOR OPERATED DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) ROUND DUCT SYMBOL FLAT OVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE ---CFM SIZE THERMOSTAT /TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL 0 z 5 - MOUNTED GRIT I F PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2006 IBC, 2006 WSEC, 2006 IMC & 2006 WSVIAQC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. DISCREPANCIES PRIOR PROCEEDING WITH STHE DETAILS, NOTIFY ENGINEER OF ANY 5. SHA N BOENTHEUSAME DETAILS S FOR OTHER OSIMI SHOWN WORK. ED FOR ANY PART RESOLVCDDIN AILS MANNER, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL JOINTS IN SUPPLY AND RETURN AIR DUCTS SHALL BE SEALED TO SMACNA C CLASS, OR ABOVE. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OR THE FOLLOWING: A. 0% TO 100% OF THE DESIGN SUPPLY AIR B. CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. C. INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR RELIEF AND EXHAUST IS OFF BE EQUIPPED POWER MOTORIZED AS OR BY ENERGY CODE. 13. TYPES WEEK AND SHALL DEADBAND SEITINGG O F At LEAST 5 OF F BETWEEN SEVEN DIFFERENT SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE MICROPROCESSOR AND BE CAPABLE OF RESLIIING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. DUCT SYSTEMS SHALL COMPLY WITH MECHANICAL CODES AND SMACNA STANDARDS. DUCTS 28" AND LARGER, WHICH ARE SUSPENDED MORE THEN 12" BELOW STRUCTURAL SYSTEM, SHALL BE EARTHQUAKE BRACED. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL SEIZMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EbUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE /SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM PER CODE. SMOKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER- WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. A ALL VERTICALDJOINTSIGINSIDE SHAFTS SHAFT SHALL THE PROVIDED WITH�A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC) B. TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) C. ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE D. ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. E. USE SECTION 905 OF THE 2003 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. F. ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM /SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G--KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND WT H OTHERCTRADESINNS AND CONNECTIONS INOACCORDANCERWITH APPROXIMATE. SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R -7 FOR REST OF INSTALLATION). 5. R -7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM. CONDENSER WATER (FOR NON- ECONOMIZER SYSTEMS - INSULATION IS NOT REQUIRED) • APN NUMBER 2523049017 LEGAL DESCRIPTION S 329.85 FT OF GL 7 LY BET PST & P R/W & CO RD LESS ST HWY VICINITY MAP NO SCALE SITE MAP NO SCALE FILE COPY . MoB s Pfau MAW wool s $* te MRS end amens. Approval of won doh does not dze ti'sv #oIl net rny . : C or ot e. of ate' copy L- a : Receipt BY �1 >:�� MK, City of Tukwila BUILDING DIVISION MOONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. N OTE: Revisions wi l require a new plan submittal I and may include aonal plan review fees. i CODE CO MP aola A ppROV '': SAP 1 Ot TutoiviF ': BUIL SEPARATE PERMIT REQUIRED FOR: DMachanical nrElectrigi etPlumbin Whits Piping City of Tukwila BUILDING DIVISION CITY OF TUY.V4tL MAR 0 6 2008 PERMIT CENTER AD 0(eC ISSUE FOR PERMIT Design Drawn Checked Scale Issue Date Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575 -9700 Fax: (206) 575 -9800 www_hermanson.com Contractor Reg #: HERMACLOO5BJ iFLOOR TI 17616 WEST VALLEY HWY TUKWILA, WA Revisions 3 -5 -08 CG ISSUE FOR PERMIT No. Date By Description Design Team CG ER DN AS NOTED Drawing Number C- XXXX -XXX Project Number 11 -8 -0176 3-5-08 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M0.00 1 OF 2 DC OFFI 1 2 ; V EGGCRATE GRILL H'HOOD FOR TION TO fE}IIUSE PEN 12 %-2 . CONFERENCE OPL� OFEIC 113] WAITING I OPEN TO SECOND FLOOR CEILING ABOVE. " I NO LIGHTING • . OR CEILING - En CHANGE U %ER THIS PE; IT. R 'EPTION STORE INVENTORY 126 kt f7m frt n CQ 1 ! FE �ALr� . C�NFE _.... -,.,; 'Ef?ICE JFERENpE 105 NEW SUSPENDED CEILING SYSTEM AT 13'-6" A.F.F, CROSSHATCH INDICATES AREAS TO RECIEVE R -25 BATT INSULATION ABOVE CEILING GRID. - 0' - 0" NEW SUSPENDED CEILING SYSTEM AT 12' -0" A.F.F. WAREHOUSE (127) ALL WAREHOUSE AREA UGHTNG EXISTING WAREHOUSE 127 FLOOR PLAN (AREA UNDER THIS PERMIT) Scale: NEW SUSPENDED CEILING SYSTEM AT 12'-0" A.F.F. 60' -0" • 10 - SECURE STORAGE 125 715' -0" _. CROSSHATCH OPEN . INDICATES AREAS TO OFFICE - r , . RECIEVE R -25 BATT I�5ULA11ON ..- —..-- . , CEILING GRID. NEW SUSPENDED CEILING SYSTEM AT 12' -0" A.F.F. r) CEILING INSULATION PER WALL SECTION 0 (aS TITUS Pict' LAY S1v ViFfvS a.irsY caP' egg :•�. # <.,,,�... tar LArCill (gin cierwits Tiros Brae L- Tl fyxz r CEILING I LIGHTING SYMBOLS &LEGEND (EX IT1 SUSP. ACOUST. TILE CEILING AND GRID SYSTEM PER REFLECTED CEILING PLAN Scale: 1 1 /Z=1' —0" 7 /8" EXISTING SUSPENDED ACOUSTICAL TILE CEILING NEW 2' X 4' SUSPENDED ACOUSTICAL TILE CEILING NEW COMPACT FLOURESCENT LIGHT FIXTURE EXISTING 2' X 2' FLUORESCENT LIGHT NEW 2' X 2' FLUORESCENT LIGHT 0 FIXTURE W - / 2 - TB LAMPS AND ELECTRONIC BALLAST NEW 2' X 2' FLUORESCENT LIGHT WITH BATTERY BACK -UP (NIGHTIME /PATHWAY UGHTING) EXISTING 2' X 4' FLUORESCENT LIGHT NEW 2' X 4' FLUORESCENT LIGHT FIXTURE W 2 - T8 LAMPS AND ELECTRONIC BALLAST NEW 2' X 4' FLUORESCENT LIGHT WITH BATTERY BACK -UP (NIGHTIME/PATHWAY LIGHTING) EXISTING LIGHTED EXIT SIGN NEW LIGHTED EXIT SIGN NOTE: ALL RECESSED CAN LIGHTS TO BE (IC) INSULATION CONTACT RATED FIXTURES. TENT LIGHT FIXTURE W/ CEILING TILES FOR INSULATION COVER, SIMILAR TO UL DESIGN G216. 2 X4 RECESSED FLUORESCENT LIGHT FIXTURE PER REFLECTED CEILING PLAN FIXTURE TENT AT SUSP. CELING EXISTING COMPACT FLOURESCENT LIGHT FIXTURE IF HANGER WIRE IS OUT I OF PLUMB GREATER THAN 1:6 is COUNTER SPLAY PER ASTM C636 WALL WHICH PENEIHATES CEILING GRID WALL EDGE MOLDING (101' (Z/44 MIN . MAX. 8" 11 MIN. 3/4' . JN ATTA',HFD WA..11 EDGE TRACK AT SUSP. CEILING Scale: 3 " -1' —O" SEISMIC N.T.S. WALL EDGE MOLDING BRACE AT SUSPENDED CEILING SUSP CEILING BRACE AT PERIMETER N.T.S. #12 PERIMETER HANGER WIRE ANCHORED TO STRUCTURE ABOVE [� EACH MAIN BEAM OR CROSS TEE STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART © UNATTACHED WALLS ONLY TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" ( TOP TO BOTTOM) PER ASTM C636 MAIN BEAM OR CROSS TEE CEILING GRID CROSS TEE PER ASTM C635 STEEL STUD COMP . E SIQN POST AS REQUIRED 'BY-1 BUILDING OFFICAAI .r • CROSS TEE MAIN CEILING PER ASTM 0635 BEAM PER ASTM C635 CEILING INSTALLATION REQUIREMENTS PENETRATIONS. • CHANGES IN CEILING PLANE MUST HAVE POSITIVE BRACING. • CABLE TRAYS AND ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND BRACED. SUSPENDED CEILING WILL BE SUBJECT TO SPECIAL INSPECTION AS REQUIRED BY LOCAL BUILDING OFFICIAL. • IF CEILING SYSTEM TO BE INSTALLED IS NOT AS SPECIFIED ABOVE, CONTRACTOR SHALL SUBMIT ALTERNATIVE MATERIAL AND METHODS AS DESCRIBED IN I.B.C. SECTION 104.11 TO LOCAL BUILDING OFFICIAL. EXPANSION JOINT AT SUSP. CEILING Scale: 3 " =1' -0" #12 HANGER WIRE TYP. TIGHT LOOP THROUGH HANGER HOLE & THREE TIGHT TURNS WITHIN 3" TOP TO BOTTOM) • SUSPENDED CEILINGS SHALL BE BRACED AGAINST LATERAL MOVEMENT DUE TO EARTHQUAKE PER ASTM C636. IN THE ABSENCE OF AN ENGINEERED DESIGN THE FOLLOWING BRACING SYSTEM WILL BE REQUIRED. FOUR NO. 12 GA STEEL WIRES SHALL BE ATTACHED TO A MAIN RUNNER WITHIN 2 INCHES OF A CROSS RUNNER. THE WIRES SHALL BE SPLAYED 90 DEGREES TO EACH OTHER AND RUN UP TO STRUCTURE ABOVE AT AN ANGLE NOT TO EXCEED 45 DEGREES FROM THE HORIZONTAL. A COMPRESSION STRUT SHALL EXTEND FROM THE MAIN RUNNER AT THE ATTACHMENT OF THE WIRES VERTICALLY AND BE ATTAC - IED TO THE STRUCTURE ABOVE AS REQUIRED BY BUILDING OFFICIAL. SUCH BRACING SYSTEMS SHALL BE PROVIDED AT A SPACING NOT TO EXCEED 12 FEET IN BOTH DIRECTIONS, BEGINNING AT A POINT NOT TO - EXCEED 6 FEET FROM WALLS, VERTICAL AND PERIMETER HANGERS INSTALLED PER ASTM C636 AND MANUFACTURERS REQUIREMENTS. LIGHTING FIXTURES WHICH WEIGH LESS THAN 56 POUNDS SHALL BE ATTACHED TO THE CEILING GRID SYSTEM AND TO BUILDING STRUCTURE BY AT LEAST 2 NO 12 GAGE WIRES. LIGHT FIXTURES WHICH WEIGH 56 POUNDS OR MORE SHALL BE SUSPENDED FROM THE STRUCTURE INDEPENDENT OF THE CEILING GRID, AND AN ENGINEERING DESIGN SHALL BE SUBMITTED TO SUBSTANTIATE THE SUSPENSION SYSTEM. MECHANICAL EQUIPMENT SHALL BE SUPPORTED INDEPENDENT OF THE CEILING SUSPENSION SYSTEM. • MINIMUM 2" WIDE WALL MOLDING • GRID MUST BE ATTACHED TO TWO ADJACENT WALLS - OPPOSITE WALL MUST HAVE A 3/4" CLEARANCE. • ENDS OF MAIN BEAMS AND CROSS TEES MUST BE TIED TOGETHER TO PREVENT THEIR SPREADING. • PERIMETER SUPPORT WIRES MUST BE WITHIN 8" OF CEILING EDGE. • PROVIDE MANUFACTURERS HEAVY DUTY GRID SYSTEM. • CEILING AREAS OVER 1,000 SF MUST HAVE HORIZONTAL RESTRAINT WIRE OR RIGID BRACING. • CEILING AREAS OVER 2,500 SF MUST HAVE MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT REVIEW PARTmONS.� �� • CEILINGS WITHOUT RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER STABILIZER BAR SYSTEM TO KEEP PERIMETER COMPONENTS FROM SPREADING APART 0 UNATTACHED WALLS ONLY R:7' - -.. CITY UYYv LA MAR Q 6 2008 PERMIT CENTER #12 HANGER WIRE ANCHORED TO STRUCTURE ABOVE EXPANSION JOINT PER CEILING MANUF. X 11 ' Cyr Of Tuk1 ' 1 BULL DImg_a V(S [EXPIRES 1/29/W10 e