Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M08-072 - WESTFIELD SOUTHCENTER MALL - RACHA THAI & ASIAN KITCHEN
RACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL M08 -072 Parcel No.: Address: Suite No: Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: doc: IMC - 10/06 6364200010 1150 SOUTHCENTER MALL TUKW RACHA THAI & ASIAN KITCHEN 1150 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA PAUL JOSEPH CitAbf Tukwila Address: 4426 221 PL NE , REDMOND WA Contractor: Name: PERFECT CLIMATE INC Address: 4426 221 PL NE , REDMOND WA Contractor License No: PERFECIO22D5 Value of Mechanical: $40,000.00 Type of Fire Protection: Furnace: <100K BTU 0 >100K BTU 0 Floor Furnace 0 Suspended/Wall/Floor Mounted Heater 0 Appliance Vent 0 Repair or Addition to Heat/Refrig /Cooling System.... 0 Air Handling Unit <10,000 CFM 2 >10,000 CFM 0 Evaporator Cooler 0 Ventilation Fan connected to single duct 1 Ventilation System 0 Hood and Duct 0 Incinerator: Domestic 0 Commercial/Industrial 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT DESCRIPTION OF WORK: INSTALL (2) 15 TON PACKAGE ROOFTOP UNITS AND DUCTWORK FOR RESTAURANT TENANT IMPROVEMENT. INSTALL RESTROOM EXHAUST FAN AND DUCTWORK EOUIPMENT TYPE AND OUANTITY * *continued on next page ** M08 -072 • Permit Number: Issue Date: Permit Expires On: Phone: Phone: 425 - 260 -6955 Phone: 206 - 977 -7353 Expiration Date: 03/11/2010 M08 -072 04/08/2008 10/05 /2008 Fees Collected: $620.00 International Mechanical Code Edition: 2006 Boiler Compressor: 0 -3 HP /100,000 BTU 0 3 -15 HP /500,000 BTU 0 15 -30 HP /1,000,000 BTU.. 0 30 -50 HP /1,750,000 BTU.. 0 50+ HP /1,750,000 BTU 0 Fire Damper 0 Diffuser 0 Thermostat 0 Wood/Gas Stove 0 Water Heater 0 Emergency Generator 0 Other Mechanical Equipment Printed: 04 -08 -2008 Permit Center Authorized Signature: 7 Date: D'"1 Y r I hereby certify that I have read and governing this work will be complie Signature: doc: IMC -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us The granting of ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the p rformanc of ork. I am authorized to sign and obtain this mechanical permit. Print Name: / /7 �t i o S " • Permit Number: M08 -072 Issue Date: 04/08/2008 Permit Expires On: 10/05/2008 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. M08 -072 Printed: 04 -08 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: doc: Cond -10/06 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1150 SOUTHCENTER MALL TUKW RACHA THAI & ASIAN KITCHEN 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 5: Readily accessible access to roof mounted equipment is required. 11: ** *FIRE DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS • Permit Number: Status: Applied Date: Issue Date: M08 -072 ISSUED 03/11/2008 04/08/2008 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila Permit Center. 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto - shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2051) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air - moving equipment upon detection of smoke in the main return-air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2051) M08 -072 Printed: 04 -08 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2051) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: Cond -10/06 * * continued on next page ** M08 -072 Printed: 04 -08 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the _nezformance of work. Signature: / 04- Print Name: / ,,C)SP - ) )/ i doc: Cond -10/06 M08 -072 Date: ordinances governing or local laws regulating Printed: 04 -08 -2008 CITY OF TUKWIL" Community Developmeiir Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us MECHANICAL PERMIT APPLICATION Mechanical 'rermit No. M() e Project No. Q 7 � (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION i King Co Assessor's Tax No.: 6 (-(2 O '-CDO) O, Site Address: , A,f - yh rry 1 - 1 \ Suite Number: Tenant Name: t ., \2-t New Tenant: Property Owners Name: C.A., t✓Z'p S . C ry �1Z Mailing Address: )1 ( -,UA. W g -e„ lP--1._ -.v CONTACT PERSON - who do we contact when your permit is ready to be issued Name: ?p} -,,, iS Mailing Address: L142 ( ZZ\ L 1°LC E -Mail Address: # PC-L1 Pi T ( I`vi L ( u,� Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Contact Person: E -Mail Address: Contact Person: E -Mail Address: C. LArn 1 ti( q u(2-G 2_2_\ 5' �L yi L Q:\ApplicationsWorms- Applications On Linel3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Z City Day Telephone: TZ S— 24‘ v- 6S Cs Zip City Fax Number: City Day Telephone: Fax Number: C/) • State State ` ( 2 - 2 _ 6 b - 6 5 ST Expiration Date: 3 - 1 1— ) Floor: .Q ❑ .... Yes ❑ ..No State State Cjc�uZf Zip MECHANICAL CONTRACTOR INFORMATION - L-tA- 1 ) S 3 State Zip v- 6 �2S - S ARCHITECT OF RECORD - All plans must be w stamped by Architect of Reco Company Name: Mailing Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECORD - Alt plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Day Telephone: Fax Number: Zip Page 1 of 2 Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace >100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct I Thermostat 15 -30 HP /1,000,000 BTU Suspended /Wall/Floor Mounted Heater Ventilation System Wood /Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP /1,750,000 BTU Repair or Addition to Heat /Refrig /Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Comm /Ind Other Mechanical Equipment Valuation of Project (contractor's bid price): $ 11 U !>vL� , i Scope of Work (please provide detailed information): l Sj 1 : ) \\ ) \ < T U ru G-IC t — bZ o C,c ) fu S yr,- \ S3 P\ 77 Le �X \-1 AAv - Dta ca" tti s Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... Replacement .... ❑ Fuel Type: Electric ❑ Gas ....0 Other: Indicate type of mechanical work being installed and the quantity below: PERMIT APPLICATION NOTES — Applicable to all permits in this a pplication Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNJR OR AUTHORIZED AGENT: Signature: / /o` (fr Print Name: ?PA,. 1 � Mailing Address: L/ t- /2 22.- 5 Date Application Expires: 1-(1-00 Date Application Accepted: Q.\ Applications \Fonns- Applications On Line \3 -2006 - Mechanical Permit Application.doc Revised: 4 -2006 bh Date: ) ' — O i G Day Telephone: 2 " G � 7 - .2-e0 L-tA � G S >' City State Zip Staff Initials: 1 Page 2 of 2 Parcel No.: 6364200010 Permit Number: M08 -072 Address: 1150 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/11/2008 Applicant: RACHA THAI & ASIAN KITCHEN Issue Date: Receipt No.: R08 -01075 Initials: JEM Payment Date: 04/08/2008 01:14 PM User ID: 1165 Balance: $0.00 Payee: PERFECT CLIMATE INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8389 360.00 ACCOUNT ITEM LIST: Description PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Account Code Current Pmts 000/345.830 360.00 Total: $360.00 Payment Amount: $360.00 0933 04 /08 0711 TOTAL 360.00 doc: Receiot -06 Printed: 04 -08 -2008 Receipt No.: R08 -00698 Initials: WER User ID: 1655 Payee: PERFECT CLIMATE ACCOUNT ITEM LIST: Description MECHANICAL - NONRES PLAN CHECK - NONRES City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: M08 -072 Address: 1150 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/11/2008 Applicant: RACHA THAI & ASIAN KITCHEN Issue Date: TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8359 620.00 Account Code Current Pmts 000.322.102.00.0 496.00 000/345.830 124.00 Total: $620.00 Payment Amount: $620.00 Payment Date: 03/11/2008 10:04 AM Balance: $0.00 9752 03/11 4710 TOTAL. 620.00 doc: Receiot -06 Printed: 03 -11 -2008 COMMENTS: 1aVi :iei 4-- eve IrZlirfi 1 k - rvil*le ,,yy l'107-13-14 Ware SiI &f pow-1 Set t4 1- - 4 i - Date Called: t" • -t t 0, 7I1 k / r :✓`•` t Special Instructions: Date Wanted: 2 -11-e° a.m. p.m. Requester: Phone No: Project: Type of Inspection: Address: IIfO /1 Date Called: Special Instructions: Date Wanted: 2 -11-e° a.m. p.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD 114 D7oa Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION S . 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ig Approved per applicable codes. Corrections required prior to approval. Inspector_ Date: 7 • El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be • paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: • Project: �a1 � - r Ty o Inspection: Address i' 5O &W., Date Called: Special Instructions: Date Wanted: �'1� l61 (7 a.m. P.m. Requester: Phone No: INSPECTION NO. INSPECTION RECORD Retain a copy with permit NCO$ -0 ine 7 - 072„ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4' 5 £ate f Q ( eIS (\ a p Inspector'` ` rate: ri $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: 'Date: Proj t: __.— A �;� ' A T)-t 14-1- Type of Inspection: 1� Q1 icn u " —tki Address: 1H5O mAt1 Date Called: Special Instructions: Date Wanted: �-1 _ 2 S — rJ I a.m- p.m. Requester: Phone No ....6 6 - 61 -11 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. it••• l CITY OF TUKWILA BUILDING DIVISION POP- 07? 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Approved per applicable codes. ❑ Corrections required prior to approval. Z COMMENTS: r f n IL-- 1) 5tt L A 7 F__ A Ins or: Da - 1 /4•.Mta 1 z s= dJ 018.00 REINSPECTIO FEE REgt IRED. Prior o inspection fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: Receipt No.: Project: Aticr, rLA le. lei Type of Inspection: (19‘ h Me, I-7 Address: i I'O SdhrAhfP N.11 Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: 2 ,96 611 Ifo3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 El Approved per applicable codes. M 06 -497,2 PERMIT NO. (206)431 -3670 © Corrections required prior to approval. COMMENTS: 9 Afd M)1"/4 4- On I 1 l Inspector Date: 4 1-22 'log $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: k+_.. 14 r _ i _ a ' 61 .. Eet,. J' 1 COMMENTS: Sprinklers: Type of Inspection: / 1 4 pc k `i I ct i Address: , !� b Suite #: S M I I -i Special Instructions: M oGh4k,2E r F-i,. I . k - S (16, ii p►i 1, \J(.,-,t J 1 1 1 i I , 1 Project: j K c t c, Lt C 1 T e l G1 + Sprinklers: Type of Inspection: / 1 4 pc k `i I ct i Address: , !� b Suite #: S M I I Contact Person: &'k R 0V4-L Special Instructions: Phone No?!. 6' Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 -575 -4407 Z Approved per applicable codes. Word /Inspection Record Form.Doc 1/13/06 i -'; 0 C ? - ti N[ O ' a 07 PERMIT NUMBERS rrectio q fired prior to approval. Inspector: Date: Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. T.F.D. Form F.P. 113 Fan Equipment Schedule Equip. ID Brand Name' Model No.' CFM Sp HP /BHP Flow Control Location of Service EF T LA �4,1v,?., OW ,'7c R 14 5 — 9 c0 i () 2O t.i) 2anfTior RECE Cooling Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV Location �i L. L o. TC7A t'doSAS S liAb boot Co 'V'oN to . 1 2O t.i) 2anfTior Heating Equipment Schedule Equip. ID Brand Name' Model No.' Capacity Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency° �i L. - ENN ©lk MA i S2. iSS 24 , D i ow (nniy n e'C nto 2 b 000 2O t.i) �O 1) Z Project Info Project Address Date SST �.,¢. ,A - For Building dept. Use • -• - • - • Applicant Name: 41-6 �F�• CLI/YiA�� '��f � � 48os; Applicant Address: 4 LI 26 2 1 S s D 1.. J n,s - " - b Applicant Phone: KZS Z643-6c Cc i CITY OF TUKWILA BUILDING DIVISION •2006 Washington State Nonresidential Energy Code Compliance Form Mec hanica'I Summary 7 - t. t r mF r _- M E H - S•U,M. 2006 Washington State Nonresidential Energy Code Compliance Forms Project Description Briefly describe mechanical system type and features. Odes Plans Compliance Option Equipment Schedules c Mod -o7 2 FILE COPY 1- N5TINA Ca) f .LN,TS EC-'- "^'19-r►t 2 1LS $ 'Dun"' S(MoK.E Orcr Include documentation requiring compliance with commissioning requirements. Sectic K Simple System Q Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & com The following information is required to be incorporated with the mechanical equipme plans. For projects without plans, fill in the required information below. a , Revised July 2007 /_ EWED FOR CODE COMPLtANCE n 1416. APPROVE IVED MAR 11 2008 HERMIT CENTER •Mechanical Permit.Plans 2006 Washington State Nonresidential Energy Code Compliance Forms f =CHK Revised July 2007 . MECH Project Address 'Date The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency 1411.1 Combustion htg. Indicate intermittent ignition, ftu &draft damper & jacket Toss 1412 HVAC controls 1412.1 Temperature zones Indicate locations on plans 1412.2 Deadband control Indicate 5 degree deadband minimum 1412.3 Humidity control Indicate humidistat 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types . 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage • 1412.4.2 Optimum Start Indicate optimum start controls 1412.5 Heat pump control Indicate microprocessor on thermostat schedule 1412.6 Combustion htg. Indicate modulating or staged control 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas 1422 Thermostat interlock Indicate thermostat interlock on plans 1423 Economizers Equipment schedule 1413 Air economizers 1413.1 Air Econo Operation Indicate 100% capability on schedule 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance 1413.3 Integrated operation Indicate capability for partial cooling 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems 1414.1 Duct sealing Indicate sealing necessary 1414.2 Duct insulation Indicate R -value of insulation on duct 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report 1434 Separate air sys. Indicate separate systems on plans Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WA f ER HEA 1 INU AND HEA 1 ED POOLS (Sections 1440 -1454) 1440 Service water htg. 1441 Elec. water heater Indicate R -10 insulation under tank 1442 Shut -off controls Indicate automatic shut -off 1443 Pipe Insulation Indicate R -value of insulation on piping 1452 Heat Pump COP Indicate minimum COP of 4.0 1452 Heater Efficiency Indicate pool heater efficiency 1453 Pool heater controls Indicate switch and 65 degree control 2006 Washington State Nonresidential Energy Code Compliance Form System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: • Constant vol? • Air cooled? • Packaged sys? • <20.000 Btuh? • Split system? • Economizer included? If Heating Only: g y 0 <5000 cfm? o 0 <70 /o outside air? • CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. • START ) Heating Only No Heating/Cooling or Cooling Only Yes - Reference l Section 1421 1 J otal Ca . wo economize <240,000 Btuh or 10 %? Simpl ysf€m Alloviei 1 (s4420) Reference Section 1423) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washin ton State Nonresidential Ener Code Com•Iiance Form Mechanical Pere it,Plans Checklis 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a produ ct covered in Tables 14 -1A through 14 -1G. and it includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (110), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces. that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Sery ice Water Heating: For combination space and service water heaters with a principal function of providing space heat. the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment prov ding both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. Al a minimum. each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling. zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and co oling energy to the zone is shut off or reduced to a minimum Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4. if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive. and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture. a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full Ica d demands of 2 kW (6.826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain dosed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. T412.8 Ventilation controls for High - occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area. and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper. or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for meth anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb/40 ° F wet -bulb and below. For this calculati on. all factors including solar and internal load shall be the same as those used for peak load calculations. except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air to mperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate. capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical coding is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btulh and use nonintegrated economizer controls that prelude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type) Exceptions: 1. Health care facilities where WAC 246 -320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadlabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand atone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be seated in accordance with Standard RS- 18. Extent of seating required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints. longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.0 or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air Leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2.800 cfm of total supply air capacity shall be insulated EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 2006 Washin ton State Nonresidential Ener Code Com•Iiance Form Mechanical Pere it,Plans Checklis 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -CHK Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a produ ct covered in Tables 14 -1A through 14 -1G. and it includes provisions for verification and challenge of equipment efficiency ratings. then the product shall be listed in the certification program. Gas -fired and oil -fired forced air furnaces with input ratings > 225,000 Btu/h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (110), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable altemative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All furnaces with input ratings > 225,000 Btu/h (65 kW), including electric furnaces. that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be furnished by the equipment manufacturer. 1411.3 Combination Space and Sery ice Water Heating: For combination space and service water heaters with a principal function of providing space heat. the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packag equipment prov ding both heating and cooling with a total cooling capacity greater than 20, Btu/h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. Al a minimum. each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling. zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and co oling energy to the zone is shut off or reduced to a minimum Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4. if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive. and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture. a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or alternate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full Ica d demands of 2 kW (6.826 Btu/h) or less may be controlled by readily accessible manual off -hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close au tomatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain dosed until activated by the fire a larm system or other approved smoke detection system. Exceptions: 1. Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. T412.8 Ventilation controls for High - occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area. and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper. or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct- digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and retum air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for meth anical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer, at outside air temperatures of 45 ° F dry- bulb/40 ° F wet -bulb and below. For this calculati on. all factors including solar and internal load shall be the same as those used for peak load calculations. except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 ° F dry-bulb outside air to mperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate. capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical coding is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btulh and use nonintegrated economizer controls that prelude simultaneous operation of the economizer and mechanical cooling. 2. Water - cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type) Exceptions: 1. Health care facilities where WAC 246 -320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadlabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand atone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be seated in accordance with Standard RS- 18. Extent of seating required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints. longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at stati c pressures of 1 inch W.0 or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These re quirements include insulation installation, moisture control, air Leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2.800 cfm of total supply air capacity shall be insulated 2. Combustion air Intakes 2006 Washington State Nonreside 3. Gravity (nonmotonzed) dampers are acceptable in buildings less than 3 stories in height 4. Gravity ( nonmotonzed) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings • three or more stories in height 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply air capacities exceeding 10.000 cfm shall have optimum start controls. Optimum start controls shall be designed to automatically adjust the start time of an HVAC system each day to bring the space to desired occupied temperature levels immediately before scheduled occupancy The control algorithm shall, as a minimum. be a function of the difference between space temperature and occupied setpoint and the amount of time prior to scheduled occupancy. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up. set- up, and defrost conditions. These controls shall anticipate need for heat and use compression heating as the first stage of heat. Controls shall indicate wfien supplemental heating is being used through visual means (e.g., LED indicators). 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225.000 Btu/hi shall have modulating or staged combustion control. 000 EXCEPTIONS: 1. Boilers. 2 Radiant heaters. 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have a means for balancing, including but not limited to, dampers, temperature and pressure test connections and balancing valves. ntistilEraegArGegley GE1613p}06g1cEr@LRlces to a minimu m of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2.800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they. 1. connect to the heating or cooling equipment. or 2. are isolated from the exterior with an automatic shut -off damper complying with Section 1412.4.1. Once outside air ducts meet the above listed requirements. any runs within conditioned space shall comply with Table 14 -5 requirements. Other ducts and plenums shall be thermally insulated per Table 14 -5. Exceptions: 1. Within the HVAC equipment. 2. Exhaust air ducts not subject to condensation. 3. Exposed ductwork within a zone that serves that zone. 1415 Piping Systems 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6 Exception: Piping installed within unitary HVAC equipment Water pipes outside the conditioned space shall be insulated in accordance with Washington State Plumbing Code (WAC 51 -26) 1416 Completion Requirements (Refer to NREC Section 1416 and the Building Commissioning Guidelines. published by the Building Commissioning Association. for complete text and guidelines for building completion and commissioning requirements.) G�. r... • FIDE COPY South Center Thai Joseph Perfect Climate Inc 4426 221 Sst P1 NE Redmond, WA 98053 -2812 Phone: +1 (206) 9777353 Project Information: U444P460G5 -03 South Center Thai Redmond, WA Redmond, WA Prepared By: Anh Welch (anh.welch@lennoaind.com) Lennox Industries Inc. Product Submittal MO&07 November 8, 2007 Lennox Industries 13101 SE 84th Ave Clackamas, Oregon 97015 Phone: 503 -654 -6232 FAX: 503- 786-0713 REVIEWED FOR CODE COMPLIANCE APPROVED APR - 2 2008 t i ' Qj a4 Of Tukwila LDI r IVISI We are pleased to provide the attached projed submittal If you have any questions or need adddional Information, please feel free to call our office. RECEIVE MAR 11 2008 PERMIT CENTEF, Plan ID Quantity Description Page 3 15 Ton Pkg Gas 2 TGA180S2BS PkgGE/I5Ton/260Kb/460 -3 Lennox Industries Inc. - Product Submittal South Center Thai Submittal Nbr. U444P460G5 -03 Table of Contents November 8, 2007 Redmond, WA Lennox Industries Inc. - Product Submittal November 8, 2007 South Center Thai Redmond, WA Unit ID: 15 Ton Pkg Gas SPECIFICATIONS AND RATINGS Packaged Cooling & Gas Heating Model number TGA180S2BS PkgGE/l5Ton260Kb /460 -3 HEATING PERFORMANCE Heat source Natural Gas Gas supply connection 1.0 (in.) Mechanical: Heating capacity input (low stage) 169,000 (Btuh) Mechanical: Heating capacity input (high stage) 260,000 (Btuh) Mechanical: Heating capacity output (high stage) 208,000 (Btuh) Mechanical: AGA -CGA thermal efficiency 80.0% Mechanical: Temperature Rise 32.0 (deg F) COOLING PERFORMANCE ARI gross cooling 186,000 (Btuh) ARI net cooling 180,000 (Btuh) ARI total unit watts 18,600 ARI EER (Btuh/Watts) 9.7 ARI integrated part load value 10.1 Number of Compressors 3 Outdoor air thy bulb temperature 95.0 (deg F) Mixed air dry bulb temperature 80.0 (deg F) Mixed air wet bulb temperature 67.0 (deg F) Direct Expansion: Gross total cooling 186,000 (Btuh) Direct Expansion: Net Total Cooling 177,461 (Btuh) Direct Expansion: Gross sensible cooling 139,500 (Btuh) Direct Expansion: Net Sensible Cooling 130,961 (Btuh) Direct Expansion: Moisture Removal 44.4 (lb / hr) Coil Discharge dry bulb temperature 56.8 (deg F) Coil Discharge wet bulb temperature 56.6 (deg F) Unit Discharge dry bulb temperature 57.8 (deg F) Condensate drain size 1.00 fpt (in.) Refrigerant type R -22 SUPPLY FAN PERFORMANCE Supply fan total air flow 6,000 (CFM) External static pressure - supply side 0.80 (in. W.C.) Wet coil static pressure 0.03 (in. W.C.) Gas Heat Exchanger Static Pressure 0.07 (in. W.C.) Total Static Pressure 0.90 (in. W.C.) Supply Fan power 2.82 (bhp) Supply fan motor nominal power 3.0 (hp) Required RPM 817 RPM range 710 - 965 Air filter quantity 6 Air filter length x width 24 x 24 (in.) Air filter thickness 2 (m ELECTRICAL Submittal Nbr: U444P460G5-03 Product Database Updated: 10/18/2007 3:31:18 PM Page 3 of 7 Lennox Industries Inc. - Product Submittal November 8, 2007 South Center Thai Redmond, WA Power supply 460 V 3 Phase Unit operating range + or - 10% Blower motor full load amps 4.8 Compressor RLA (total) 22.5 Condenser fan motor watts. 1,370 Condenser fan full load amps (total) 5.2 System full load amps 32.5 System MOCP (amps) 40 System minimum circuit ampacity 35.0 DIMENSIONS Dimensions 54.25(h) x 91.125(w) x 129.5(d) (in.) Down -flo supply air opening 20.0(1) x 28.0(w) (in.) Down -flo return air opening. 15.0(1) x 60.5(w) (in.) Horizontal supply air opening 14.0(h) x 75.0(w) (in.) Horizontal return air opening 15.0(h) x 60.5(w) (in.) Total installed unit weight. 2,527 (lbs.) EQUIPMENT FEATURES Durable Outdoor Enamel Paint Finish Copeland Scroll Compressor Pre- charged Refrigeration System Expansion Valves High Capacity Driers Separate Compressor and Controls Compartment Totally Enclosed Fan Motor PVC Coated Fan Guard Fan and Limit Controls Factory Test Operated Bonded for Grounding Internal Pressure Relief Valve Overload Protection Timed Off Control Units will operate cooling down to 35 degrees F. (1.7 degrees C.) Limited warranty on ahnninized heat exchanger of 10 years Limited compressor warranty of 5 years Limited warranty on all other components of 1 year See Limited Warranty Certificate included with unit for details FACTORY INSTALLED OPTIONS Constant Volume Belt Drive Blower Air Filter Type - 2" Pleat MERV 7 Std Filter Blower Motor - 3 Hp Std Blower Drive Kit -1 (710 -965 RPM) Gas Heating - 260K Btuh Aluminized Steel Tubular Heat Exchanger FIELD INSTALLED OPTIONS MATERIAL CIHOODIOC -1 Outdoor Air Hood Pkg _ 85425 TIECONIOC -1 Economizer 86M31 LARMFI8 /36 Roof Curb /14" 16K87 LB- 90945A Smoke Detector Kit - Return Air 7 0K86 LAGED 18/24 Barometric Relief Damper 16K98 C1HOOD20C -1 Exh Hood/Downflow GED 85M26 Submittal Nbr. U444P460G5-03 Product Database Updated: 10/18/2007 3:31:18 PM Page 4 of 7 Lennox Industries Inc. - Product Submittal November 8 206 South Center Thai Redmond,\Y CISNSRO6AE1 Single Enthalpy Sensor Kit 86M32 Submittal Nbr: U444P460G5-03 Product Database Updated: 10/18/2007 3:31:18 PM Page 5 of 7 Lennox Industries Inc. - Product Submittal South Center Thai 602 273 673 305 lbs. ku CORNER WBGHTS BB CC lbs. ka 470 213 518 235 lbs I ku Ibs. MI 502 228 677 307 536 243 714 324 Inch 51 -1/2 51 -1/2 Model Number 180S Base Unit 180S Max. Unit Sex oral - Uri ur8A NO OPTIONS. Mar. the - Uhi with ALL OPTIONS 6hstaSxL (Eoonoehnr, Pourer Exhaust Fens. controls) l e- - 904/81220M 1 R 41—a1 R, f� mineNBiaeotus '� ----- 91 -1j8 R8+5) END VIEW smE Eumnacm. looamms AA -u 60- eoTToN B n�e s nm ON6�m 41 1 1 002) I 4tTar4 NOTION POeIHI ENTRY 5x Sloane 027x2mre) OPTIONAL TOP VIEW 1291/2 ('9 CENTER 0 GRAVITY EE FF mm inch mm 1308 39-1/2 1 1003 1308 42 -1/2 1080 n11E ouTLET % ■o wo + e) 1291/2 (8289) SIDE VIEW November 8, 2007 Redmond, WA BB cc Submittal Nbr: U444P460G5_03 Product Database Updated: 10/18/2007 3:31:18 PM Page 6 of 7 ACCESSORY DIMENSIONS - INCHES (MM) STANDARD ROOF CURBS - DOUBLE DUCT OPENING 1 -13/16 1 -13/1 ( 88-1/8 (2188) g O 82-5/8 (2099) - 13-14 (210) E 1 v -13/16 (48) 86.1/4' (2190.75) 21• 533.4) - 114' 102 -1/8 (2594) TOP VIEW Frame 98-1/2 (2502) Oveg 61/'4 61 -1/2 (1562) O) 16 (406) CURB RETURN l I AIR OPENING 17 (432) 3/4 (19) Typ. 44--- 61 -1/2 (1562) 21 or CURB SUPPLY AIR OPENING 7, J 1 -13/16 rd- 1a 356 LARMF18/36 -14 24 610 LARMF18/36 -24 STRIP ) 2(51) SECTION A-A A 1 CLIPLOCK 1000 ROOF CURBS - DOUBLE DUCT OPENING T-class Packaged Gas / EIec6tc 15 to 25 tons / Page 30 A NAILER STRIP C1= �) _ - -4 - 1021/2 (2604) NOTE — Roof deck may be omitted within confines of curb. SIDE VIEW ' CL ) (Jfu 14356 LARMF18/36 -14 24 (61 LARMF18P36 -24 Sones LwA dBA @ 5. dBA X 10 ' dBA 4 2 fr Octave Band Sound Power (LwA) 123 Hz 250 Hz 500 Hz r 1000 Hz 2000 Hz 4000 Hz 8000 Hz 7.9 66 55 49 43 63 Hz I I I 1 1 1 Type CRBA Belt Drive Centrifugal Power Roof Ventilator BDD Gravity Dante PFCI Roof Curb AMERICAN COOLAIR CORPORATION Accessories A B I 23 2135/8 1 22 1/2 TAG: EF-1 L c Tip Speed: 4,127 ft/min B DIA. A SQ. I.D. Dimensions in Inches unless otherwise noted Outlet Velocity: 234 ft/min Sheet of • Non-overloading aluminum wheel computer balanced • Force ventilated motor compartment isolated from airstream • Variable pitch motor pulley • Vibration isolators on drive frame • Weatherproof spun aluminum housing • tIEMA Standard open drip -proof motors • Overlapping wheel/inlet venturi • Heavy duty self-aligning pillow - block bearings wilt' cast iron housing • UT galvanized mesh birdscreen • UL Listed for Standard 705 (most models) EAT_ IAO OAO GOIFOE arTGaanon '• InTE•narton FL' inc, City Fan Data Model No. CFM iMNg RPM I BHP CRBAl2GD1231 D2 I 800 1 0.750 I 1 0.165 Motor Data Accessories MHP I RPM I Voltage/Ph I Hz 1 EncL 1/4H 1750 115V/230V 1PH 60 OPEN BDD PFC1 1.0 OA OA 0.4 02 OA Fan Performance Curve • 270 900 'W 1.000 Volume Flaw Rate(CFfq 1 ,200 020 0.19 O09 0.00 1 ~0 00 RACHA ENGINEER PERFECT CLIMATE PROJECT LOCATION TUKWILA CONTRACTOR PERFECT CLIMATE SUBMITTED BY APPROVED BY DATE 12282007 DATE Fm2SB.ECT v. 5.4.0 FILE COPY Pr " it r STRUCTURAL CALCULATION FOR - *MET/NE 5ECTO nF OPENINGS FO MECHANICAL SYSTEM FOR RACHA THAI & ASIAN KITCHEN WESTFIELD MALL, TUKWILA, WA STRUCTURAL ENGINEER: JOHN C.L. CHOU PE. SUNRISE ENGINEERS, INC. SEATTLE, WA .a c`'ti • • ,. • Es �,s.• ,5i " �. �... ,ACA/09 HO8O7 z CODE REWEVVED MPL IAN %E APPROVED PR - 2 2008 . 11,1 A. O Of ukwlla 14 I 1 cY MAR 112008 P ERMVT CENTER �X rS A.. fG !� W /C- D EC. F l L._ () cf q5 A4 1 3 L 3Kx,3 1/,1y E->c rs7'IN - G a. [mil - M�ii 3M BaliOND C z 5 cii.S CA-L ( N e. 7' 0 P Jam! l Qv rz l6 W /D T sc �: ; _ t � r\ry ail Y a j h :mss �� n p a a=z- -J Z'4 'M NJJ_SJ �--- -- -- 7 - -d ► rc0 -J c3 :! W I I/2_51 x-f rz X 1ST.. -4 L. ./V z3tv ? ; L L_ -- 0 x a 5 ti L "x3 � r/ , - x (S - r, wr FLA— l 5 5LAA4 Am CDN C. R0 O1'E (!VG u JE R Lc; cLJRE S C E - r L i � - = 1 w V v \ W24x68 (118) c =1 1/2' W24x68 (118) c =1' W30x90 U 1 4x2E`rt9T c=3/ W30x116 TS6x6x J8 HI I &L0. W16x26 (36) c =3/4' cu v s 116x26 (37) c =3/4' v A W1zlx? (22) INDI ' ' = /• = DGE 6 "SEE ARCH'L SLAB L OPENING PLAN FOR SLAB EDGE LOCATION . O = ROW CONNECTION _ = D (TRANSFER INFO MATION OF DRAG CONNECTION FROM S2.13, S2.14, S . 15 , & S2.161 4 5' 1st FLOOR ROOF LINE uhf /.3 x EXISTING PARAPET BY MALL s RY QTNFRS ALL EQUIPMENT CAN NOT EXCEED THE PARAPET HEIGHT (8' UP FROM ROOF LEVEL) BY OTHERS s NORTH SITE / ROOF PLAN SCALE 1/4' = 1' -0' SHAPE SHEAR ft SIZE "TYPIMING SU D -5 PECKING QNLY REMARKS W10 OR LESS 1/4' 3/16' 2 -7/8'0 2 -7/8"0 W12, W14 1/4' 3/16' 3 -7/8 "0 3 -7/8'0 W16 3/8' 5/16' 4- 7/8'0 4 -7/8 "0 W18 3/8' 5/16' 5- 7/8'0 5 -7/8'0 W21 3/8' 5/16" 6- 7/8'0 6 -7/8'0 SEE NOTE 7 W24 1/2' 5/16' 7 -7/8'0 7 -7/8'0 SEE NOTE 7 W27, W30 1/2" 3/8" 8- 7/8'0 A490N BOLTS 8 -7/8'0 A49GNV BOLTS SEE NOTE 7 W33, W38 5/8' 7/16' 10-1'0 M90 BOLTS 10 -1'0 A90 BOLTS NOTE 7 BM. TO BM OR BM. TO COL FLG, 3 2" MIN. BEAM - TO COL WE 1. USE A325N BOLTS TYP. USE A32SSC FOR MOVE T FRAME CONNECTIONS. SEE DETAILS 12, 13 & 20 OF 'MS SHEET FOR DRAG BEAM CONNECTIONS (USE M90SC BOLTS FOR DRAG BEAM CONN.) 2. PROVVE FIAT. HEIGHT SHEAR PLATE FOR BM. TO GIRDER CONNECTIONS FOR ALL PERIMETER GIRDERS. 3. PROVIDE FULL HEIGHT SHEAR PLATE FOR BM. TO GIRDER CONNECTIONS FOR RIGID FRAME GIRDERS OR BRACED FRAME GIRDERS. 4. DRAG LAS ARE GIB LIKES CONTAINING MOMENT FRAME & BRACED FRAME. AND AS NOTED ON PLANS. 5. SEE DETML 7/- FOR SKEWED BEAM CONNECTION. 6. MINIMUM EDGE DISTANCE SHALL. BE 1 1/2'. USE GAS CUT OR SAW CUT EDGE FOR PLATE WITH 1'0 BOLTS. 7. FOR W21 x 122 MD LARGER USE 1/2' SHEAR PL. W/3/8' WELD *0 1 A490 -X BOLTS. FOR W24x117 AND LARGER USE 1/2' SHEAR PL. W/3/8' WELD AND 1'0 M90 -X BOLTS. FOR W27x129 AND LARGER USE 5/8' SHEAR PL. W/7/16' WF1D AND 1 A490 -x 80115. FOR W30x132 AND LARGER USE 3/4' SHEAR PL. W/7/16' WELD AND 1 1/8'0 M90-X BOLTS. FOR W33x141 AND URGER USE 1' SHEAR PL. W /1/2' WELD AMA 1 1/8'0 M90-X BOLTS. FOR W36x150 AND LARGER USE 1' SHEAR PL. W/1/2' WELD AND 1 1/8'0 A490 -x BOLTS (AT DRAG BEAM USE A490SC BOLTS) TYPICAL BOLTEL CONN. I£ 1 /2' T&8, UNO / f TO COL � FLGS 3/8 SEE \ SCHED I 2 6 1YP. CONC. FLOOR OPENING DETAIL 11 METAL DECK W/ 2-44 . TACK WELD TO TOP OF I DEECCIK( TYP. AS SHOWN SINGLE OPENING (B) GROUP OF OPENV 1. • • NOT CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPDONGS NOT CUTTING WEBS REQUIRE NO ANGLES. 3. F OPENINGS OR HA AR S ME CUT THRU PECK K BEFORE WELDED POURED. REPLACE 2 BY L 2x2x1/4 W /3110 A T 1 00.0 TOP OF DECK ND ADO 180A. 4. C CON OPENINGS OR GROUP OF OPENING EXCEEDING 10" OR CUTTING 2 WEBS REQUIRE SEOONDARY BEAM REINFORCEMENT AS PER DETAIL 11/— TYP. METAL ECK ROOF/FLOOR OPEN`G W� CQNC. TQl?IDING 12 MECH. CURB CONC. TOPPING SEE PLAN SECTION A —A 11 71 K 1/21, NELS1UDS x4" L0. 0 32" O.C. CLOSURE PL TYP. PROVIDE 3/18* BEM PI EDGE FORMS AROUND OPN'GS, TYPICAL Cax11.5 TYP. a : 0 C10x15.3 OR W12x14 PLAN FLOOR BEAMS SEE PLAN 1. • 2 . _a ������ c c gi WM f . a L Gomm » I J H -' 1YP. CONC. FLOOR OPENING DETAIL 11 METAL DECK W/ 2-44 . TACK WELD TO TOP OF I DEECCIK( TYP. AS SHOWN SINGLE OPENING (B) GROUP OF OPENV 1. • • NOT CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPDONGS NOT CUTTING WEBS REQUIRE NO ANGLES. 3. F OPENINGS OR HA AR S ME CUT THRU PECK K BEFORE WELDED POURED. REPLACE 2 BY L 2x2x1/4 W /3110 A T 1 00.0 TOP OF DECK ND ADO 180A. 4. C CON OPENINGS OR GROUP OF OPENING EXCEEDING 10" OR CUTTING 2 WEBS REQUIRE SEOONDARY BEAM REINFORCEMENT AS PER DETAIL 11/— TYP. METAL ECK ROOF/FLOOR OPEN`G W� CQNC. TQl?IDING 12 MECH. CURB CONC. TOPPING SEE PLAN SECTION A —A 11 71 K 1/21, NELS1UDS x4" L0. 0 32" O.C. CLOSURE PL TYP. PROVIDE 3/18* BEM PI EDGE FORMS AROUND OPN'GS, TYPICAL Cax11.5 TYP. a : 0 C10x15.3 OR W12x14 PLAN FLOOR BEAMS SEE PLAN 0 N METAL. DECK W/ CONC. FILL A L c2.. rc r W f �C� ?a ` 4 LG. � ILL_ET w L_D t2 "�_�• ma U fiC J 1YP. METAL DECK ROOF OPEN G w CONC_ TOPPING • SINGJ.E QPEN ING B S ROUP OF OPEN'GS N Mal 1. DO Nar CUT OPENINGS IN DECK UNTIL 7 DAYS AFTER CONC. HAS WEN POURED 2. SINGLE OPENINGS NOT CUTTING WEBS REQUIRE NO ANGLES. 3. IF OPENINGS OR HOLES ARE CUT THRU AF CONC. IS POURED, PP- - _.. L 2x2x1/4 W/ 3118 x 2"t.G. I .ET W DE AT 12' O.C. TO BEST OF DE K AND ADO CLOSURE . AROUND OPENINGS.. 4. CONC. OPENINGS OR GROUP OF SING EXCEEDING 16 CUTTING 2 WEBS REQUIRE SECOIDARY AIM REINFORCEMENT AS PER DETAIL 12 ENGINEERING DATA Brand/Family hi T = T-Class' Product Line ASHRAE 90.1 COMPLIANT I Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Nominal Cooling Capacity - Tons 180 = 15 Tons 210 = 17.5 Tons 240 = 20 Tons 300 =25 Tons Cooling Efficiency S = Standard Efficiency H = High Efficiency LC o� n• NE T W 0 R K 15 to 25 Tons Net Cooling Capacity - 180,000 to 286,000 Btuh Gas Input Heat Capacity - 260,000 to 480,000 Btuh T GA240S2 BS 1 Y Refrigerant Type r^) 2 =R22 REGISTERED QUALITY SYSTEMS I-1 Voltage Y = 208/230V-3 phase -60hz G = 460V-3 phase -60hz J = 575V-3 phase -60hz Minor Design Sequence 1 =1st Revision 2 = 2nd Revision 3 = 3rd Revision Heating Type S = Standard Gas Heat, 2 Stage M = Medium Gas Heat, 2 Stage H = High Gas Heat 2 Stage Blower Type B = Constant Air Volume (CAV) - Belt Drive Bulletin No. 210417 June 2005 Supersedes May 2005 ENERGY STAR Voltage - 60hz - 3 phase 208/230V 460V 575V Compressors Rated Load Amps (total) 15.6 (46.8) 7.5 (22.5) 6 (18) ( Locked Rotor Amps (total) 124 (372) 59.6 (178.8) 49.4 (148.2) Outdoor Fan Full Load Amps (total) 2.4 (9.6) 1.3 (5.2) 1 (4) Motors (4) Locked Rotor Amps (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Standard PEF (2) Horsepower (W) 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps(total) 4.8 (9.6) 2.6 (5.2) 2 (4) Locked Rotor Amps (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.6) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps Indoor Blower Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Motor Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 Minimum Circuit with power exhaust 76 82 90 37 40 44 30 32 35 AmIacitY without power exhaust 71 77 85 35 38 41 28 30 33 1 Maximum Over- with power exhaust 90 90 110 40 45 50 35 35 40 current Protection without power exhaust 80 90 110 40 40 50 30 35 40 Disconnect 84M14 84M13 84M13 Voltage - 60hz - 3 phase 208/230V 460V 575V Compressors Rated Load Amps (total) 15.4 (46.2) 7.4 (22.2) 5.9 (17.7) ( Locked Rotor Amps (total) 124 (372) 59.6 (178.8) 49.4 (1482 Outdoor Fan Full Load Amps (total) 2.4 (9.6) 1.3 (5.2) 1 (4) Motors (4) Locked Rotor Amps (total) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Standard PEF (2) Horsepower (W) 1/3 (249) 1/3 (249) 1/3 (249) Full Load Amps(total) 4.8 (9.6) 2.6 (5.2) 2 (4) Locked Rotor Amps (total) 9.4 (18.8) 4.8 (9.6) 3.8 (7.6) Service Outlet 115V GFI 15 Amps 15 Amps 15 Amps indoor Blower Horsepower 3 5 7.5 3 5 7.5 3 5 7.5 Motor Rated Load Amps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Locked Rotor Amps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Minimum Circuit with power exhaust 76 82 89 37 40 43 30 32 35 AmpaChY without power exhaust 71 77 84 35 37 41 28 30 33 I Maximum Over- with power exhaust 90 90 110 40 45 50 35 35 40 current Protection without power exhaust 80 90 110 40 40 50 30 35 40 Disconnect 84M14 84M13 84M13 .n J.rr � �. J x.Y. �;}' rc aw,ay.• la.�..:.>- •.wa.,. INSTAL IIIONit1- 411�ANCESr:; liid0,0 M11 !il) Octave Band Sound Power Unit Levels dBa, re 10 Watts Model Center Frequency - HZ No. 125 250 500 1000 2000 4000 v OUTDOOR AIR HOOD 4 • re /. 1 41 (1041) 180 210, 240 300S NOTE - Top Clearance 60 In. (1524 mm). NOTE - Entire perimeter of unit base requires support when elevated above mounting surface. 1 NOTE - 66 in. (1676 mm) Recommended service clearance for blower deck removal 2 NOTE - 60 In. (1524 mm) Recommended service clear- ance for heat exchanger removal NOTE - Extremes of operating range are plus and minus 10% of line voltage. 1 HACR type breaker or fuse. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. e3a. " ^Pry.' •+KA E.E�TRICA'�DATA. �� �" `��.' '� � y,� �,�.y.,,_ 15 TON STANDARD EFFICIENCY (R -22) 15 TON HIGH EFFICIENCY (R -22) 97 94 96 92 91 93 91 90 90 88 87 87 83 83 82 79 79 76 72 72 65 8000 1 Sound Rating Number (dB) 93 92 93 Tested according to ARI Standard 270-95 test conditions and ANSI Standard S1.32 -1981. TGA180H2 T - Class Packaaed Gas / Electric 15 to 25 tons / Pace 19 TGA180S2 a. ` �A ' CaC SS ItY D 1111 ENS" N.S -= I ( CHES MM) STANDARD ROOF CURBS - DOUBLE DUCT OPENING 1 -13/16 (46) 1 -13/1 (48) 1 co E m O 82 -5/8 (2099) II 1/4 (210) 86-1/8 (2188) � -NJ I � -- 61 -1/2 (1562) (210) 16 (406) CURB IR OPENING 98 1/2 (2502) Opening 17 (432) 3/4 i 9) Typ. 4 41— --- 61 1/2 (1562) CURB SUPPLY AIR OPENING 4 1 -13/16 (46i_ 1 ( 25 ) 14 356 LARMF18/36 -14 24 (610) LARMF18/36 -24 NAILER S (F 2 (51) SECTION A -A / A i 4 -13/16 (46) CLIPLOCK 1000 ROOF CURBS - DOUBLE DUCT OPENING 86 -1/4' 2190.75) 21" 533.4) /1l\ (209 5 102 -1/8 (2594) TOP VIEW 1 -1/2" 98 -1/2' (2070.1) 61 -112' (2501.9) (1562.1) \ T1:I200 Partlranarl [:aa 1 Flarfrir. 15 to 95 tnna / Pana !1/1 Frame (46) MIN. A 4 NAILER STRIP (Furnished) 1=J _ — = — J -4 = r- ' 14 356 LARMF18/36 -14 24 (610) LARMF 8/36 -24 NOTE — Roof deck may be omitted within confines of curb. SIDE VIEW 102 -1/8" (2593.975) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP 102 -1/2 (2604) 14 (356) 18 (457) 24 (610) DISCARD DUCT SUPPORT WHEN USING FOR OTHER THAN LARMF -18/36 CORNER DETAIL TOP EDGE TYPICAL BOTTOM SLOT FLANGE TYPICAL LOCKING TAB WOOD NAILER STRIP 1 ! Damper Section (down -flow) - Automatic T1 DAMP20C -1 52 24 Damper Section (down -flow) - Manual LAOAD18 /24 49 22 Outdoor Air Hood (down -flow) C1 HOODI OC-1 65 29 Power Exhaust LAPEFI8 /24 62 28 • **EIGHT°' Mode Number Step -Down Flush Transitions Economizer 180S/210S Base Unit 180S/210S Max. Unit Barometric Relief TA 180H/240S Base Unit 180H/240S Max. Unit 210H/240H/300 Base Unit 210H/240H/300 Max. Unit OPTIONS / ACCESSORIES CEILING DIFFUSERS ECONOMIZER / OUTDOOR AIR / EXHAUST Down -Flow Barometric Relief Dampers Horizontal Barometric Relief Dampers Outdoor Air Dampers HEAT EXCHANGER Medium Heat Heat Exchanger High Heat Heat Exchanger PACKAGING LTL Packaging (less than truck load) ROOF CURBS - STANDARD Down -Flow 14 in. (356 mm) height 24 in. (610 m) height Horizontal 26 in. (660 mm) height 37 in. (940 mm) height ROOF CURBS - CLIPLOCK 1000 Down -Flow Horizontal RTD11 -185 RTD11 -275 FD11 -185 FD11 -275 LASRTI 8 LASRT21 /24 T1 ECON10C -1 LAGEDI 8/24 LAGEDH 18/24 LARMFI 8/36 -14 LARM F18/36 -24 LARMFH18 /24 -2f; LARMFH18 /24 -37 14 in. (356 mm) height LARMF18 /30S -14 18 in. (457 mm) height LARMFI8 /30S -18 24 in. (610 mm) height LARM F 18/30S-24 26 in. (660 mm) height LARMFHI8 /24S -26 37 in. (940 mm) height LARMFH18 /24S -37 Base Unit - The unit with low fire heat exchanger NO OPTIONS. Max. Unit - The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls) Net lbs. kg 2251 1021 2441 1107 2345 1064 2535 1150 2470 1120 2660 1207 Shipping lbs. kg 2451 1112 2641 1197 2545 1154 2735 1241 2670 1211 2860 1297 Weight lbs. kg. 392 178 403 183 289 135 363 165 80 36 75 86 30 20 95 105 280 34 39 14 9 43 48 127 160 73 220 100 420 191 580 263 164 74 187 85 222 101 335 152 445 202 T -Class Packaaed Gas / Electric 15 to 25 tons / Paae 27 I2 March 21, 2008 Paul Joseph 4426 — 221' Place Ne Redmond, WA 98053 RE: CORRECTION LETTER #1 Mechanical Application Number M08 -072 Racha Thai and Asian Kitchen —1150 Southcenter Mall Dear Mr. Joseph, This letter is to inform you of corrections that must be addressed before your plumbing permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen, at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) complete sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted throuffh the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Permit Coordinator Encl xc: File No. M08 -072 • City of Tukwila P:\Pennit Center \Correction Letters\2008\M08 -072 Correction Ltr #1.DOC wer • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: March 20, 2008 Project Name: Racha Thai & Asian Kitchen Permit #: M08 -072 Plan Review: Allen Johannessen, Plans Examiner Tukwila Building Division Allen Johannessen, Plan Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plan shows several roof penetrations requiring structural framing for the new openings. Please provide a table that specifies what special inspection methods are required for the structural revisions to the roof system. (IBC 1704.3.1 & 1704.3.3) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. ACTIVITY NUMBER: M08 -072 DATE: 03 -27 -08 PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: 1150 SOUTHCENTER MALL _ Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEP RTMENTS: Buil Public Works ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Permit Center:Use Only , INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP REVIEWER'S INITIALS: Documents/routing slip.doc 2 -28-02 Fire Prevention Incomplete Structural Review Required APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Structural ❑ Permit Coordinator DUE DATE: 04 -01 -08 Not Applicable ❑ No further Review Required I.4 DUE DATE: 04 -29 -08 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: M08 -072 DATE: 03 -11 -08 PROJECT NAME: RACHA THAI & ASIAN KITCHEN SITE ADDRESS: 1150 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: Buil g Division Public Works DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Documents/routing slip.doc 2 -28-02 • * PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP n 10 51te 3•i oiD Fire Prevention Structural ❑ Permit Coordinator Incomplete APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: u n Planning Division DUE DATE: 03 -13 -08 DATE: Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required U No further Review Required REVIEWER'S INITIALS: DATE: n DUE DATE: 04 -10 -08 Not Approved (attach comments) F Permit Center Use Only CORRECTION LETTER MAILED: I • O6 61--' Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Date: Project Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc Project Address: 1 l 50 SoLt1 -Gies k..- fli, / 1 Ti-tku ); C4 Contact Person: a ; z.4 )Liw,1,,�,• Phone Number: Summary of Revision: Spy L nsp I e3 QcJ d' 14-4 s ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner R C/ c_114 7/14 i Entered in Permits Plus on \appIicationssfbrms- applications on linelrevision submittal Plan Check/Permit Number: Vt 0c1- 0 7 Z Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: M ,, , Steven M Mullet, Mayor Steve Lancaster, Director RECEIVED CITY OF TUKWItA MAR 2 7 2008 PERMIT CENTER WA 9/5 r i 2L)6 41Z4) License Information License PERFECIO22D5 Licensee Name PERFECT CLIMATE INC Licensee Type CONSTRUCTION CONTRACTOR UBI 601844179 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 4426 221ST PL NE Address 2 City REDMOND County KING State WA Zip 98053 Phone 2069777353 Status ACTIVE Specialty 1 HTGNENT /AIR CONDITIONING Specialty 2 UNUSED Effective Date 3/25/1998 Expiration Date 3/11/2010 Suspend Date Separation Date Parent Company Previous License PERFEC *054DB Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC SB4087 03/01/2002 Until Cancelled $6,000.00 03/11/2002 #1 CBIC SB4087 03/01/1998 03/01/2002 $4,000.00 Business Owner Information Name Role Effective Date Expiration Date JOSEPH, PAUL G 01/01/1980 Look Up a Contractor, Electroan or Plumber License Detail Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. 1 Page 1 of 2 https: // fortress. wa. gov /1ni/bbip /printer.aspx ?License= PERFECIO22D5 04/08/2008 D E S I G N S T U D I O PLAIWIG A}D tl41 B OR DESIGN 1405 BOYLSTON AYE SEAT I E, WA 913122 TE.. 206 .3224328 E-IIIIAECATCIOAOM VAIAV.CATCHSPDO.COM ENGINEER Jo BLACKLAW 7224 JAILS I. SW ROCI*ESTER WA 98579 ARCHITECT RAIVALL C. FONG KfTCI- N DESIGN BARMEN Ell2sIGSON 36271 ST AVE SOUTH SEATTLE ,WA 98134 RIME 208.682.1472 FAX: 206.11 22367 PROJECT TITLE: RAEHA THAI & ASIAN If 37'O:i WESTFIELD MAJ.L C11KIPoLA, WA) TSS1-EET TITLE ON CATCH DESIGN STUDIO DRAWN NOS NARK DATE 01/23/08 SCALE AS NOTED SHEET# Al 1 ,J NORDSTROM 171.275sf 3 LEVELS 1 74.S30sf 3 LEVELS macys 250,4O7sf 4 LEVELS ENCLOSED MALL 1 LEVEL LOSED 3 LEVE FUTURE RETAIL 65,237sf 2 LEVELS JCPenney 2 76 . 45 3 LE 1 FIRESTONE I SITE PLAN N.TS. YY 11 '' 411ZIP. CD VICINITY MAP r ri v n I' ri STRANDER BOULEVARD (E) TARGET ABBREVIATIONS ACT = ACOUSTICAL CEILING TILE AFF = ABOVE FINISHED FLOOR CW = COLD WATER EX = EXPLOSION PROOF FCIC = FURNISHED & INSTALLED BY CONTRACTOR F010 = FURNISHED & INSTALLED BY OWNER FOIC = FURNISHED BY OWNER INSTALLED BY CONTRACTOR FRP = FIBERGLASS REINFORCED PANEL FS = FLOOR SINK GWB = GYPSUM WALL BOARD LEGEND CD, SHEET NUMBER DETAIL SHEET NUMBER SECTION SHEET NUMBER AE CEILING HEIGHT INTERIOR ELEVATION DETAILS BUILDING SECTIONS REVISIONS CEILING NOTE T S fZ ce w 0 0 Q J r L Baum V V J O 1 t w x •t tr O V _ 1 / - FACTORY - THE OLIJE 1 77558uf GA EN ~ -, F x.405 SF �F L II KEY HIIIHIIIIIHIIII IItI HW = HOT WATER LRV = UGHT REFLECTANCE VALUE NIC = NOT IN CONTRACT RCP = REFLECTED CEIUNG PLAN TBD = TO BE D. IuMMINED TYP = TYPICAL UNO = UNLESS NOTED OTHERWISE WP = WEATHER PROOF +46° = INDICATES HEIGHT ABOVE FINISHED FLOOR OR ABOVE FINISHED GRADE TO TOP OF DEVICE. WALL TYPES ENLARGED PLANS /DETAILS COLUMNS OR GRID UNES TEMPERED GLASS SPANDREL GLASS GE\ ER AL \OTES: A. GENERAL NOTE: 1. THE CONTRACTOR IS RESPONSIBLE FOR ALL COORDINATION BETWEEN SUBCONTRACTORS BASED ON ENTIRE SET OF DOCUMENTS. NO EXTRA COMPENSATION WILL BE GIVEN TO A BIDDER OR SUPPLIER WHO HAS BID FROM AN INCOMPLETE SET OF CONSTRUCTION DOCUMENTS. IN CASE OF INCONSISTENCIES OR DISCREPANCIES BETWEEN DRAWING THE MOST STRINGENT NOTE OR CONDITION SHALL APPLY AND THE CONTRACTOR SHALL NOTIFY OWNER /ARCHITECT OF SUCH DISCREPANCIES. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE EXISTING SITE CONDITIONS AND DIMENSIONS PRIOR TO STARTING CONSTRUCTION. 3. THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A CURRENT SET OF CONSTRUCTION DRAWINGS ON SITE DURING CONSTRUCTION. THE CONTACTOR SHALL INDICATE ON THESE PLANS ALL APPROVED CHANGES TO THIS WORK. THIS SET SHALL BE TURNED OVER TO OWNER /ARCHITECT WHEN THE PROJECT IS COMPLETE. 4. IF ANY ERRORS, DISCREPANCIES OR OMISSIONS APPEAR ON THESE DRAWINGS, SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS, THE CONTRACTOR SHALL NOTIFY OWNER /ARCHITECT IMMEDIATELY. 5. NO MATERIAL SUBSTITUTIONS WILL BE ALLOWED UNLESS SUBMITTED IN WRITING TO OWNER /ARCHITECT FOR APPROVAL IN WRITING. NOTIFICATION MUST BE SUBMITTED WITHIN 10 WORKING DAYS OF CONTRACT. 6. THE CONTRACTOR IS REQUIRED TO PROVIDE A LIST OF ALL SUBCONTRACTORS TO BE USED AND SUBMIT UST TO THE OWNER /ARCHITECT WITHIN 10 WORKING DAYS OF CONTRACT AWARD. 7. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING IN AND VERIFYING ALL SHIPMENTS OF OWNER SUPPLIED MATERIALS. THIS INCLUDES VERIFYING PACKAGING LISTS AGAINST ORDER FORMS ABD BILLS OF LOADING. IF THIS IS NOT DONE, THE CONTRACTOR WILL BEAR THE COST OF ANY EXPEDITED FREIGHT CHARGES TO MEET THE CONSTRUCTION SCHEDULE. THE CONTRACTOR IS RESPONSIBLE FOR FILING DAMAGE REPORTS AND MUST MAINTAIN PACKING MATERIALS FOR SHIPMENT OF DAMAGED ITEMS. 8. THE CONTRACTOR SHALL KEEP ALL HANDBOOKS AND PAPERWORK INCLUDING ALL PACKAGING SLIPS LANDING IN A MARKED ENVELOPE. THIS ENVELOPE IS TO BE TURNED OVER TO THE OWNER. 9, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEAN UP OF ALL TRADES. 10. THE DRAWINGS ARE NOT TO BE SCALED. 11. THESE DRAWINGS ARE NOT TO BE ALTERED IN ANY WAY WITHOUT WRITTEN AUTHORIZATION FROM OWNER OR FROM OWNER'S ARCHITECT. 12. G.C. TO PROVIDE AND COORDINATE INSTALLATION OF TEMPORARY BARRICADES AND DUST PROTECTION AS REQUIRED BY BUILDING OWNER. 13. ALL CONSTRUCTION TO CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. 14. ALL DIMENSIONS ARE TO EITHER THE CENTERLINE OR TO THE FACE OF STUDS, UNLESS NOTED OTHERWISE. 15. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF LIGHTING WITH ELECTRICAL DRAWINGS. 16. ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL LIGHT FIXTURE SUPPORTS. GENERAL REQUIREMENTS: 1. DETAILS ARE INTENDED TO SHOW THE METHOD AND MANNER OF ACCOMPLISHING WORK. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT THE JOB DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING ANY WORK. 2. VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE BEFORE STARTING ANY WORK. 3. VERIFY LOCATION AND SIZE OF ALL OPENINGS WITH ALL DRAWINGS AND MANUFACTURED ITEMS WHERE APPLICABLE. 5. GLASS AND GLAZING SHALL CONFORM WITH THE CODE, AND WITH THE U.S. CONSUMER PRODUCT SAFETY COMMISSION REQUIREMENTS. GLAZED OPENINGS WITH LESS THAN 18 INCHES ABOVE ADJACENT FLOOR SHALL BE TEMPERED GLASS APPROVED FOR IMPACT HAZARD. 6. IN ALL INSTANCES PROVIDE ISOLATION OF ALUMINUM FROM ADJACENT STEEL. 7. MECHANICAL VENTILATION FOR MECHANICAL /UTILITY ROOM SHALL BE IN THE AMOUNT OF ONE (1) COMPLETE AIR CHANGE EVERY 8 TO 10 MINUTES MINIMUM. SEE MECHANICAL DRAWINGS. 8. PROVIDE ALL NECESSARY BACKING AND FRAMING FOR WALL - MOUNTED ITEMS, LIGHT FIXTURES AND ALL OTHER ITEMS REQUIRING SAME. 9, ROOF DRAINS DISCHARGING WATER MUST BE CONDUCTED UNDER SIDEWALK. B. SECURITY REQUIREMENTS: 1. GLAZED OPENINGS WITHIN 40 OF THE DOOR LOCK WHEN THE DOOR IS IN THE CLOSED POSITION SHALL BE FULLY TEMPERED GLASS. 2. PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM OUTSIDE WHEN THE DOOR IS CLOSED SHALL HAVE NON- REMOVABLE HINGE PINS. IN ADDITION, THEY SHALL HAVE MINIMUM 1/4" DIAMETER STEEL JAMB STUD WITH 1/4" MINIMUM PROJECTION UNLESS THE HINGES ARE SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE HINGE PINS ARE REMOVED. 3. DEAD BOLTS SHALL CONTAIN HARDENED INSERTS. 4. STRAIGHT DEADBOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8 ". 5. A HOOK- SHAPED OR AN EXPANDING LUG DEADBOLT SHALL HAVE MINIMUM THROW OF 3/4" 6. CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. C. ENERGY REQUIREMENTS: 1. OPENINGS IN ENERGY INSULATED WALLS SHALL BE PROPERLY WEATHER- STRIPPED OR GASKETED TO LIMIT AIR INFILTRATION. 2. A CERTIFICATE OF COMPLIANCE FOR INSULATION INSTALLATION SIGNED BY THE INSULATION CONTRACTOR AND THE GENERAL CONTRACTOR SHALL BE PROMINENTLY POSTED ON THE SITE. D. FIRE RE UIREMENTS: 1. ALL REQUIRED EXITS SHALL OPEN FROM INSIDE WI THOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. EXIT DOORS SHALL SWING IN THE DIRECTION OF THE EXIT. EXITS: 1. ALL REQUIRED CORRIDORS WILL HAVE A MINIMUM WIDTH OF 66 ". 2. AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A PUBLIC WAY. 3. EXIT PATHS OR WALKWAYS TO PUBLIC WAY SHALL BE CLEARLY DELINEATED. EXIT PATHS MAY BE DELINEATED BY PAINTED LINES, RAILINGS, BARRIER POSTS, WALKS, OR OTHER APPROVED MEANS. 4. EXIT DOORS SHALL SWING 'IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING 50 OR MORE PERSONS. SPECIAL NOTES: 1. TENANT CONTRACTOR SHALL PERFORM FIRST -CLASS WORKMANSHIP. ACCEPTANCE CONTINGENT UPON LANDLORD APPROVAL. 2. AFTER PROPERTY OWNER APPROVAL, ANY CHANGES OR MODIFIC11ONS IN THE DOCUMENTS OR TENANT IMPROVEMENTS MUST BE APPROVED BY PROPERTY OWNER IN WRITING. 3. TENANT CONTRACTOR WILL REPAINT AND/ OR REPAIR LANDLORD PROPERTY (NEUTRAL PIERS, BULKHEAD, REAR CORRIDOR, ETC.) DAMAGED DURING TENANT IMPROVEMENT. 4. "HAZARDOUS SUBSTANCE" IT IS THE RESPONSIBILITY OF THE TENANT AND THE TENANT'S CONTRACTOR(S) , WHEN PREPARING FOR AND PROCEEDING WITH CONSTRUCTION IN THE PREMISES, TO COMPLY WITH ALL REQUIREMENTS OF ALL APPLICABLE LAWS CONCERNING HAZARDOUS SUBSTANCES. THE TENANT SHALL NOT PERMIT THE INSTALLATION OR USE OF ANY HAZARDOUS SUBSTANCES IN ANY COMPONENT OF THE PREMISES DURING ITS TENANCY. 5. TENANT IS LIABLE FOR COMPLIANCE WITH ALL REQUIREMENTS OF LANDLORDS FIRE PROTECTION ENGINEERS DURING ORIGINAL CONSTRUCTION AND ALL SUBSEQUENT FIELD INSPECTIONS. 6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR WITH DESIGNER TO FIELD VERFY DIMENSIONS, UTILITY LOCATIONS AND CONDITIONS BEFORE AND DURING CONSTRUCTION. 7. ALL REUSED MATERIAL AND EQUIPMENT MUST BE REFURBISHED TO "LIKE NEW" CONDITION. 8. APPROVAL IS SUBJECT TO VERIFICATION OF CONDITIONS AND COMPLIANCE WITH PROCEDURES FROM LOCAL PROPERTY OWNER PROPERTIES AUTHORITY. 9. ALL MATERIALS USED IN THE CONSTRUCTION OF THIS SPACE MUST BE ASBESTORS FREE. 10. ALL MODIFICATIONS TO THE SPRINKLER SYSTEM ARE TO BE PERFORMED BY A LANDLORD APPROVAL CONTRACTOR AT THE TENANT'S EXPENSE. 11. iT SHALL BE NOTED BY THE GENERAL CONTRACTOR AND ALL SUB - CONTRACTORS THAT THIS SET OF PLANS AND THE INFORMATION CONTAINED WITHIN THEM, IN NO WAY RELIEVES SAID PARTIES OF THEIR RESPONSIBILITY TO INVESTGATE AND COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES AND TO PERFORM ALL WORK TO THE HIGHEST OF STANDARDS MISCELLANEOUS: 1. BUILDING OCCUPANTS SHALL SECURE PERMITS REQUIRED BY THE FIRE DEPARTMENT FROM THE FIRE PREVENTION BUREAU PRIOR TO OCCUPYING THE BUILDING. 2. BUILDING NUMBERS SHALL BE EASILY VISIBLE LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. ADDRESS BOTH SIDES OF PROPERTY. FIRE PROTECTION EQUIPMENT: 1. SEPARATE PLANS FOR AUTOMATIC FIRE SPRINKLER SYSTEM, FIRE ALARM SYSTEMS, AND ANY OTHER PLANS FOR FIXED FIRE PROTECTION EQUIPMENT SHALL BE SUBMITTED TO THE FIRE MARSHAL FOR APPROVAL PRIOR TO INSTALLATION. LEGAL DESCRIPTION ON FILE SCOPE OF WORK TENANT IMPROVEMENT: NEW RACHA THAI IN NEW BUILDING. PROJECT STATISTICS PROJECT ADDRESS: CODES USED: ZONING: TYPE OF CONSTRUCTION: TAX PARCEL NO.: PROJECT AREA: STORY: PROJECT PROJECT ADDRESS: OWNER: LANQLORD: ARCHITECT: EliGINEEK OPERATOR'S DESIGNER: KITCHEN DESIGNEE? INFORMATION RACHA THAI & ASIAN KITCHEN 633 SOUTHCENTER MALL TUKILA, WA SPACE: R5 THAI FOOD INTERNATIONAL 6313 6TH AVE. SOUTH SEATTLE, WA 98108 TEL: (206)768.8883 CONTACT PERSON: KANE BUNYAKETU TEL: (206)579.7725 WESTFIELD SOUTHCENTER MALL PROJECT MANAGER: JOSH KIMMEL 11601 WILSHIRE BLVD, 9TH FLOOR LOS ANGELES, CA 90025 JKIMMEL @WESTF1ELD.COM TEL (310)893.4761 RANDALL C FONG JOHN BLACKLAW 7224 JAMES RD.SW. ROCHESTER, WA 98579 CATCH DESIGN STUDIO 1405 BOYLSTON AVE. SEATTLE, WA 98122 (206) 322 -4323 NOS NARIN BARGREEN ELUNGSON 3627 1ST AVE. SOUTH SEATTLE, WA 98134 TEL: (206)682.1472 COMMERCIAL FULLY SPRINKLERED 636420 - 0010 6326 S.F. 1ST FLOOR INDEX OF DRAWINGS SPECIAL HAZARDS: I. BUILDING DEPARTMENT NOTES: SOUTH CENTER MALL NOTES: 633 SOUTHCENTER MALI SEATTLE, WA 98188 (R5) 2006 INTERNATIONAL BUILDING CODE WASHINGTON STATE ADMENDMENTS TO IBC 2006 WASHINGTON STATE Al: COVER SHEET A2: FLOOR PLAN A3: EQUIPMENT UST, ROOM FINISH SCHEDULE, DOOR SCHEDULE A4: FLOOR FINISHING PLAN A5: REFLECTED CEIUNG PLAN A5.1: CENTER DECORATION DETAIL A6: FIXTURE PLAN A7: FRAMING PLAN A8: ROOF PLAN A9: DETAILS, MISC. A10: PATIO ELEVATION PLAN AND WALL SECTIONS All: STOREFRONT ELEVATION, PLAN AND DETAILS Al2: FENCE ELEVATION DETAILS, LIGHTING POLE A13: MALL SIDE STOREFRONT ELEVATION AND DETAILS A14: PA110 AREA, MALL WALK PAVING SI: STOREFRONT SECTION, DETAILS S2: CANOPY SECTION DETAILS S3: FRAMING, STOREFRONT CALCULATION 1. RUBBISH ROOM SHALL BE OF ONE -HOUR FIRE - RESISTIVE CONSTRUCTION AND BE EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM. 2, FIRE DEPARTMENT ACCESS TO ROOFS IN THE EVENT OF A FIRE SHALL NOT BE OBSTRUCTED BY WIRES, RAZOR RIBBON, FENCES, CABLES, AERIALS, ANTENNAS, OR SOLAR PANELS. 3. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS, AND PIPING FOR HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE. 4. ROOF COVERING SHALL BE FIRE RETARDANT. 1. ALL REQUIRED PERMITS MUST BE OBTAINED FROM THE CITY OF TUKWILA BEFORE THE BUILDING 15 OCCUPIED. 2. PLANS FOR THE FIRE SPRINKLER SYSTEM, AND FIRE ALARM SYSTEM MUST BE SUBMITTED TO, AND APPROVED BY THE FIRE PREVENTION BUREAU BEFORE THIS EQUIPMENT IS INSTALLED. 3. ANY CONSTRUCTION DOCUMENTS AND DESIGNS THAT WILL NOT BE SUBMITTED FOR REVIEW AT THIS TIME NEED TO BE DESIGNATED AS DEFERRED SUBMITTALS AND HAVE PRIOR APPROVAL GRANTED FOR THEM TO BE SUBMITTED BY AN APPROVED DATE. THIS IS REQUIRED FOR ITEMS SUCH AS THE INSTALLATION OF THE SUSPENDED CEILING SYSTEM, AUTOMATIC SPRINKLER SYSTEM, PLUMBING, MECHANICAL, ENERGY (FOR TI). 4. ALL RETAIL SHOPS ARE TO BE OCCUPIED ON THIS PERMITTED SITE - THE CAPITAL MALL --- THE PROMENADE ARE TO NON- HAZARD OCCUPANCY. QUICK RESPONSE SPRINKLER HEADS MUST BE PROVIDED IF THE SPRINKLER SYSTEM IS DESIGNED AS A LIGHT-HAZARD OCCUPANCY PER NFPA. SECTION 903.3.2, ITEM 3. TENANT'S CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH ALL WITHIN THE LANDLORD'S TENANT CRITERIA MANUAL INCLUDING ITS RULES AND REQUTATIONS_ TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH CODE REQUIREMENTS. THE FIRE RATED FLOOR ASSEMBLY SHALL BY MAINTAINED. ALL PLUMBING, MECHANIACL AND ELECTRICAL DEVICES PENETRATING FLOOR SHALL BE FIRE RATED. RESTAURANT TENANTS REQUIRING BELOW GRADE WORK SHALL COORDINATE WITH LANDLORD'S BELOW GRADE UTILITIES AND ON - SITE TENANT COORDINATOR PRIOR TO INSTALLATIONS. ALL BELOW GRADE UTILITIES SHALL BE INSPECTED BY ON-SITE TENANT COORDINATOR PRIOR TO INSTALLATIONS. ALL BELOW GRADE UTILITIES SHALL BY INSPECTED BY ON -SITE TENANT COORDINATOR PRIOR TO SLAB POUR. ALL ROOF PENETRATIONS MUST BE APPROVED BY WESTIFIELD'S ON -SITE TENANT COORDINATORS. ALL FINAL WEATHERPROOFING SHALL BE DONE BY WESTFIELD- APPROVED WATERPROOFING CONSULTANT PER LANDLORD'S SPECIFICATIONS AT TENANT'S EXPENSE. TENANT'S CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER WHERE EVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISED. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST 1 HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGHT THE CITY OF TUKWILA FIRE DEPARTMENT REVlElNED FOR CODE COMPLIANCE APPROVE APR - 2 SOB Of Tukwila G DIVISION REVISIONS No of w ork shall prior approval of Tukwila Building Division. NOTE Revisions will require a new plan submittal and may include additional plan review mss. FILE PY Permit Rat ��Ar*� and GtreZ the violation of *crawls d0@S not adopted code or ordnance. Recept COVER SHEET of approved Copy and cons:Um Is ackn Ie adt BY, / Date: Y--0 4. City of Tukwila BUILDING DMMMS QN RECEIVED MAR 1 1 2008 PERMIT CENTER Mob- 012 EQUIPMENT SCHEDULEI AC 1,2 MAKE: LENNOX 210S BASE UNIT (NEW) MODEL: TGA180S 15T ❑N PACKAGED ELECT: 460 V, 30 MIN CIRC =35A, MAX= 40A HTG: 260MBH INPUT, 208MBH OUTPUT EER= 9.7,6000CFM„ WT =2527 LBS OPTIONS: ECONOMIZER, DUCT SMOKE DETECTOR, An MIN OSA= 900CFM ACi, MIN OSA= 3780CFM. CONTROLS: 7DAY PR ❑G, T —STATS EF 3 MAKE: ILG 1 MODEL: CRBA -12 ROOFTOP ELECT: 208V, 10 YHP, 800CFM. AIR DEVICE SCHEDULE: CD1 KREVGAR KR1240 24/24 LAY IN RG1 KREVGAR 88V DOUBLE DEFL. REGISTER W /OBD SWG KREVGAR S8OH FIXED BLADE R/A GRILL VENTILATION CALC: • DINING= 155 PEOPLE X 20CFM /PP = 3100CFM KITCHEN= 9 PEOPLE X 15CFM /PP = 135CFM BAR= 33 PEOPLE •X 30CFM /PP = 660CFM HOST= 1PERSON X 20CFM /PP = 20CFM DINING 1 DINING 4 CD1 50CFM CD1 25 0CFM 16 /8 RG1 350CFM C❑ ❑KING AREA CD1 700CFM DINING 2 25' OF HVAC WORK PREP, AREA T —STA AC2 FREZER 0'ps SCULLERY R/A 24/24 SWG (TYP 3) 2 CD1 500CFM 1 (TYP) DINING 3 ELEC11 CAL PAt1EL CD1 1 a 150 CFM EG JANITOR RM 100CFM WOMENS L 1 N N H H JL JL JL JL 1 J EXISTING PARAPET BY MALL 22' -10" STAINLESS STEEL TYPE I GREASE HOOD ALL EQUIPMENT CAN NOT EXCEED THE PARAPET HEIGHT (8' UP FROM ROOF LEVEL) 24' STAINLESS STEEL TYPE I GREASE HOOD SCALE MALL BEAMS SITE / ROOF PLAN 1/2' = 1' -0' COOLER NORTH HVAC HVAC 1, t2111 HVAC ON THE ROOF FUSE DISCONNECT SWITCH 3 PHASE, WP 60A 4 — #6 -3/4 "C EPA -1,3,5 FUSE DISCONNECT SWITCH 3 PHASE. WP 60A 4 - #6 -3/4"C > EPA - 7,9,11 11 ELECTRICAL RM, MALL WALL, AC2 UNIT S/A R/A RETURN AIR DUCT RESTALRANT A TURN AIR TOP OF PARAPET BEYOND ROOF MEMBRANE — CON11NUE UP BACK SIDE OF PARAPET R -21 READ INSULATION RACHA WALL PARAPET SECTION BY MALL 4 EXTERIOR FINISH TO BE SUPPLIED AND INSTALL BY TENANT. a r T.O PARAPET EL. +54.85 SECOND LEVEL EL +46.8 GR OUND LEVEL �y EL +28.85 SCALE 3/16' = 1' -0 N18 RECEIvEr MAR 112008 PERMIT CENTEF " Perfect t climate I NC0RPORAT!D PAUL JOSEPH 4426 221 ST PLACE NORTH EAST FEDMOND, WA 98053 2062777353 FAX 425835 ENGPEER PROJECT TTTLE = !!/lUGJ lC�Cl7 RAEFM T11 - 1A.1. ASLAN KITCHEN RACHA'fFLAI & ASIAN KITC B4 633 SOUTHCENT R MALL SEATTLE, WA 98188 MO SIFT TITLE HVAC RefiSIONS iNTEROR DEMO CATCH DESIGN STUDIO DRAYS NOS NAZI CIECKEDe DATE: 03/06/08 SCALD AS NOTED SIC M1 W14 P? (13) EXISTING MALL BEAMS C8X11,5 - CNEW EXISTING. MAL .B: AM C8E1L5 EXISTING MALL BEAMS D E S 1 G N S T U D I O FLA MM AND INTERIOR DESIGN 1405 BOVLSTON AVE SEATTLE, WA 98122 TEL 2062224323 E- MAUFFO•CAT HSTUDIO.000 YWWIICATCHS UDIOCCI1 ARCHITECT THAN SUTAN 206.3340892 NIERIOR DESIGN CATCH DESIGN STUDIO REGISTERED ARCHITECT THAN SUTAN STATE CF WASHINGTON RAGIi& T7iAI & ASIAN KITCHEN worm ( kocktlai coni u H J L J EXISTING PARAPET BY MALL RACHA FACADE DESIGN (SEE DETAIL 51, S2, S3,AND S4 ) c5 RACHA FACADE DESIGN (SEE DETAIL 51, S2, S3,AND 54 ) ALL EQUIPMENT CAN NOT EXCEED THE PARAPET HEIGHT (8' UP FROM RDLF LEVEL) R SCALE F T P Pl- I PL\ 1/2" = 1 1_ 0 „ Mpg -��z NORTH RECEIVE MAR 112008 PERMIT CENTER SHEET* S5 DESIGNATION STEEL DECK TYPE (GALV.) GAGE TOTAL SLAB "t" CONCRETE TOPPING STEEL DECK WELDING PATTERN MAXIMUM UNSHORED SPAN MIN 28— CONC. CONC. COMPASSIVE LOCATION PERPENDICULAR TO SUPPORT PER SHEET (36" WIDE) PARALLEL TO SUPPORT SIDELAP ATTACHMENT SPAN ONE TWO SPANS CONT. THREE SPANS CONT. STRENGHT ENDS INTERMEDIATE *D-3 VERCO W3 FORMLOCK 20 - 6" 3" LT. WT. CONC. W/WWF 6X6— W2.9XW2.9 4-3/4" 0 PUDDLE WELDS 4 0 PUDDLE WELDS 3/4" 0/ PUDDLE WELDS ©12" O.C. BUTTON PUNCH ©36" 0.C. 9'=6" 11'=6" 11'=6" f' c= 3000 PSI. 2nd floor area SPECIAL I\SPECTIO\ OTES: 1. ALL WELDING SHALL BE PERFORMED BY W.A.B.O. CERIFIED WELDERS. 2. SPECIAL INSPECTION IS REQUIRED FOR ALL WELDING. PERIODIC INSPECTION IS REQUIRED FOR SINGLE-PASS FILLET WELDS LESS THAN 5 /16 CONFORMING TO AWSD 1.1 STANDARD. 3. SPECIAL INSPECTION IS REQUIRED FOR HIGH STRENGTH BOLTING. PERIODIC INSPECTION IS REQUIRED FOR A- 325 BEARING TYPE BOLTING. CONFORMING TO AISC 360, SECTION M2.5 METAL DECK IV CONC. FILL L2"X2"X1/4" Wr3116"X2" LG FILLET FELDED @12"D.C. , TO BOTTOM OF METAL DECK SINGLE OPENING GROUP OF OPEN BD= 1. DO NOT CUT OPENINGS IN DECK uN 7 DAYS AFTER CONC. HAS BEEN POURED 2. SINGLE OPENINGS NOT CUT11NG WEBS REQUIRE NO ANGLES. 3. IF OPENINGS OR HOLES ARE CUT THRU DECK AFTER CONC. IS POURED, PROVi ND L 2x2x1/4 W/ 3/16N 2"LO. FILM WELDED AT 12" 0.C. DOT OF DECK AND ADD 16A, CLOSURE le AROUND °FININGS. 4. CONC. OPENINGS OR GROUP OF OPENING EXCEEDING 16" OR CUMNG 2 WEBS REQUIRE SECONDARY BEAM RBNFORCEMENT AS P DUAIL EXISTING METAL DECK W/CONC. FILL SCALE 4f6, -6 MAX, MECHANICAL CURB (2)34" pf MB A-325 N L3"X3"XY4" Cl OX15.3 EXISTING WIDE FLANGE FRAME BEYOND TYPICAL CONC. ROOF OPENING OVER 16" WIDE 1W=1'-o. C8X11.5 BEYOND TYR METAL DECK ROOF OPEWG W CONC. TOPPING EXISTING METAL DECK W/CON C. FILL 3(61/ -6' 0 MAX,-- 0'-3' L3"X3"XY C10X15.3 EXISTING WIDE FLANGE FRAME BEYOND BEAM UNDER MECHANICAL CURB SCALE 13'=1!--0' MECHANICAL CURB *NO CONDUITS SHALL BE EMBED IN CONCRETE TOPPING. TYPICAL CONC. TOPPI\G & STEEL DEC< SCHEDULE (BY MALL) MECH. CURB CONC. TOPPING SEE PLAN SECTION A—A EOM PROVIDE 3/16 BENT PL EDGE FORMS AROUND OPN 'GS, TYPICAL C8x11.5 TYR HILTL a KKK ; OLT _ X4 EMBED. VCR 4780) 1/z� NELSTU DS A x4" LG. 0 32" 0.C. ClOx15,3 OR Wilx14 PLAN AN FLOOR BEMs SEE PLAN P. CONC. FLOOR OPENING DETAIL .1T C8X10 5 MECHANICAL CURB / 3( 6 EXISTING METAL DECK W/CON C. FILL L3 X3"XY4" ON FAR SIDE EXISTING WIDE FLANGE BEAM AT CONC. ROOF OPENIN E aySc UNDER MECH. CURB SCALE 1W=Y-0 NOTES: 1) REINFORCING STEEL, STEEL JOIST ,AND JOIST GIRDER SHOULD CONFORM TO SOUTHCENTER MALL SPECIFICATION. (SEE DETAILS ST1) *DETAIL 1,2 REFER BY WESTFIELD MALL PROVIDE TEMPORARY SHORING AS NECESSARY DURING CONSTRUCTION. RECEIVED CITY OF TUKWILA MAR 2 7 2008 PERMIT CENTER CORRECTION R# @PIVIEL% DESIGN STUDIO PLAIMIG A FITERIOR DESIC441 1405 130YLSTON AVE SEATTLE, WA 98122 TEL 20E1222_4323 E-MALWO•CATCHSTUDIO.COM VAWLCATCHSTLIDIO.0011 STRUCTURAL ENMEER JOHN CHOU SENIOR ARCHITECT THAN SUTAN 206.334.0892 6192 ts%) REGISTERED ARCHITECT THAN SUTAN SD iE OF WASHINGTON PROJECT ME RAGA 1 & ASIAN KITCHEN oitax.%wkac(kat:com WESTFELD MALL (TUKVALA, WA) MEM' IRE CONC. °Feta DEALS REVISIONS ADD SPECIAL NEFECTION NOTES NTERIOR DESIGN: CATCH DESIGN STUDIO DRAWN NOS NAM CHECKED DATE 3/25/08 SCALE: AS NOTED FLE S6 4